Sharmeen S, Woolfork A, Hage DS. Generation of affinity maps for thiazolidinediones with human serum albumin using affinity microcolumns. I. Studies of effects by glycation on multisite drug binding. J Chromatogr B Analyt Technol Biomed Life Sci 2024; 1236:124070. [PMID: 38460447 DOI: 10.1016/j.jchromb.2024.124070] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/26/2023] [Revised: 02/09/2024] [Accepted: 02/27/2024] [Indexed: 03/11/2024]
Abstract
Human serum albumin (HSA) is known to undergo modifications by glucose during diabetes. This process produces glycated HSA that can have altered binding to some drugs. In this study, high-performance affinity microcolumns and competition studies were used to see how glycation affects the binding by two thiazolidinedione-class drugs (i.e., pioglitazone and rosiglitazone) at specific regions of HSA. These regions included Sudlow sites I and II, the tamoxifen and digitoxin sites, and a drug-binding site located in subdomain IB. At Sudlow site II, the association equilibrium constants (or binding constants) for pioglitazone and rosiglitazone with normal HSA were 1.7 × 105 M-1 and 2.0 × 105 M-1 at pH 7.4 and 37 °C, with values that changed by up to 5.7-fold for glycated HSA. Sudlow site I of normal HSA had binding constants for pioglitazone and rosiglitazone of 3.4 × 105 M-1 and 4.6 × 105 M-1, with these values changing by up to 1.5-fold for glycated HSA. Rosiglitazone was found to also bind a second region that had a positive allosteric effect on Sudlow site I for all the tested preparations of HSA (binding affinity, 1.1-3.2 × 105 M-1; coupling constant for Sudlow site I, 1.20-1.34). Both drugs had a strong positive allosteric effect on the tamoxifen site of HSA (coupling constants, 13.7-19.9 for pioglitazone and 3.7-11.5 for rosiglitazone). Rosiglitazone also had weak interactions at a site in subdomain IB, with a binding constant of 1.4 × 103 M-1 for normal HSA and a value that was altered by up to 6.8-fold with glycated HSA. Neither of the tested drugs had any significant binding at the digitoxin site. The results were used to produce affinity maps that described binding by these thiazolidinediones with HSA and the effects of glycation on these interactions during diabetes.
Collapse
Affiliation(s)
- Sadia Sharmeen
- Department of Chemistry, University of Nebraska-Lincoln, USA
| | - Ashley Woolfork
- Department of Chemistry, University of Nebraska-Lincoln, USA
| | - David S Hage
- Department of Chemistry, University of Nebraska-Lincoln, USA.
| |
Collapse
|
2
|
Iftekhar S, Rauhauser M, Hage BD, Hage DS. Determination of binding constants by ultrafast affinity extraction: Theoretical and experimental studies of optimum conditions for analysis. J Chromatogr A 2023; 1707:464307. [PMID: 37619255 DOI: 10.1016/j.chroma.2023.464307] [Citation(s) in RCA: 1] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/18/2023] [Revised: 08/14/2023] [Accepted: 08/16/2023] [Indexed: 08/26/2023]
Abstract
Ultrafast affinity extraction (UAE) is a form of microscale affinity HPLC that can be employed to quickly measure equilibrium constants for solute-binding agent interactions in solution. This study used chromatographic and equilibrium theory with universal plots to examine the general conditions that are needed in UAE to obtain accurate, precise, and robust measurements of equilibrium constants for such interactions. The predicted results were compared to those obtained by UAE in studies that examined the binding of various drugs with two transport proteins: human serum albumin and α1-acid glycoprotein. The most precise and robust conditions for these binding studies occurred for systems with intermediate values for their equilibrium free fraction for the solute (F0 ≈ 0.20-0.80). These trends showed good agreement with those seen in prior studies using UAE. It was further determined how the apparent free fraction of a solute was related to the dissociation rate of this solute, the time allowed for solute dissociation during UAE, and the equilibrium free fraction for the solute. These results also agreed with experimental results, as obtained for the binding of warfarin and gliclazide with human serum albumin. The final section examined how a change in the apparent free fraction, as caused by solute dissociation, affected the accuracy of an equilibrium constant that was measured by UAE. In addition, theoretical plots were generated to allow the selection of conditions for UAE that provided a given level of accuracy during the measurement of an equilibrium constant. The equations created and trends identified for UAE were general ones that can be extended in future work to other solutes and binding agents.
Collapse
Affiliation(s)
- Sazia Iftekhar
- Department of Chemistry, University of Nebraska-Lincoln, United States
| | | | - Benjamin D Hage
- Department of Biological Systems Engineering, University of Nebraska-Lincoln, United States
| | - David S Hage
- Department of Chemistry, University of Nebraska-Lincoln, United States.
| |
Collapse
|
3
|
Sharmeen S, Suh K, Kyei I, Jones J, Olupathage H, Campbell A, Hage DS. Immunoaffinity Chromatography for Protein Purification and Analysis. Curr Protoc 2023; 3:e867. [PMID: 37610261 DOI: 10.1002/cpz1.867] [Citation(s) in RCA: 1] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 08/24/2023]
Abstract
Immunoaffinity chromatography (IAC) is a type of liquid chromatography that uses immobilized antibodies or related binding agents as selective stationary phases for sample separation or analysis. The strong binding and high selectivity of antibodies have made IAC a popular tool for the purification and analysis of many chemicals and biochemicals, including proteins. The basic principles of IAC are described as related to the use of this method for protein purification and analysis. The main factors to consider in this technique are also presented under a discussion of the general strategy to follow during the development of a new IAC method. Protocols, as illustrated using human serum albumin (HSA) as a model protein, are provided for the use of IAC in several formats. This includes both the use of IAC with traditional low-performance supports such as agarose for off-line immunoextraction and supports used in high-performance IAC for on-line immunoextraction. The use of IAC for protein analysis as a flow-based or chromatographic immunoassay is also discussed and described using HSA and a competitive binding assay format as an example. © 2023 Wiley Periodicals LLC. Basic Protocol 1: Off-line immunoextraction by traditional immunoaffinity chromatography Basic Protocol 2: On-line immunoextraction by high-performance immunoaffinity chromatography Basic Protocol 3: Competitive binding chromatographic immunoassay.
Collapse
Affiliation(s)
- Sadia Sharmeen
- Department of Chemistry, University of Nebraska-Lincoln, Lincoln, Nebraska
| | - Kyungah Suh
- Department of Chemistry, University of Nebraska-Lincoln, Lincoln, Nebraska
| | - Isaac Kyei
- Department of Chemistry, University of Nebraska-Lincoln, Lincoln, Nebraska
| | - Jacob Jones
- Department of Chemistry, University of Nebraska-Lincoln, Lincoln, Nebraska
| | | | - Avery Campbell
- Department of Chemistry, University of Nebraska-Lincoln, Lincoln, Nebraska
| | - David S Hage
- Department of Chemistry, University of Nebraska-Lincoln, Lincoln, Nebraska
| |
Collapse
|
4
|
Poddar S, Woolfork AG, Iftekhar S, Ovbude ST, Hage DS. Characterization of binding by sulfonylureas with normal or modified human serum albumin using affinity microcolumns prepared by entrapment. J Chromatogr B Analyt Technol Biomed Life Sci 2023; 1226:123798. [PMID: 37331054 PMCID: PMC10529298 DOI: 10.1016/j.jchromb.2023.123798] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/16/2023] [Revised: 06/07/2023] [Accepted: 06/09/2023] [Indexed: 06/20/2023]
Abstract
Modification of proteins can occur during diabetes due to the formation of advanced glycation end-products (AGEs) with reactive dicarbonyls such as glyoxal (Go) and methylglyoxal (MGo). Human serum albumin (HSA) is a serum protein that binds to many drugs in blood and that is known to be modified by Go and MGo. This study examined the binding of various sulfonylurea drugs with these modified forms of HSA by using high-performance affinity microcolumns prepared by non-covalent protein entrapment. Zonal elution experiments were employed to compare the retention and overall binding constants for the drugs with Go- or MGo-modified HSA vs normal HSA. The results were compared to values from the literature, such as measured or estimated using affinity columns containing covalently immobilized HSA or biospecifically-adsorbed HSA. The entrapment-based approach provided estimates of global affinity constants within 3-5 min for most of the tested drugs and with typical precisions of ±10-23%. Each entrapped protein microcolumn was stable for over at least 60-70 injections and one month of use. The results obtained with normal HSA agreed at the 95% confidence level with global affinity constants that have been reported for the given drugs in the literature. It was found for HSA that had been modified with clinically-relevant levels of either Go or MGo that an increase in the global affinity constant of up to 2.1-fold occurred for some of the tested drugs. The information acquired in this study can be used in the future to adapt this entrapment-based approach to study and evaluate interactions between other types of drugs and normal or modified binding agents for clinical testing and biomedical research.
Collapse
Affiliation(s)
- Saumen Poddar
- Department of Chemistry, University of Nebraska, Lincoln, NE 68588, USA
| | - Ashley G Woolfork
- Department of Chemistry, University of Nebraska, Lincoln, NE 68588, USA
| | - Sazia Iftekhar
- Department of Chemistry, University of Nebraska, Lincoln, NE 68588, USA
| | - Susan T Ovbude
- Department of Chemistry, University of Nebraska, Lincoln, NE 68588, USA
| | - David S Hage
- Department of Chemistry, University of Nebraska, Lincoln, NE 68588, USA.
| |
Collapse
|
5
|
Jeanroy F, Demontrond F, Vidal FX, Gueyrard D, Vidal S, Demesmay C, Dugas V. Deciphering dynamic combinatorial libraries of glycoclusters with miniaturized weak affinity chromatography coupled with mass spectrometry (nano-FAC-MS). Anal Chim Acta 2023; 1261:341227. [PMID: 37147058 DOI: 10.1016/j.aca.2023.341227] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/20/2023] [Revised: 04/12/2023] [Accepted: 04/17/2023] [Indexed: 05/07/2023]
Abstract
We report an original methodology based on affinity chromatography coupled with mass spectrometry to decipher the complexity of dynamic combinatorial libraries (DCLs) of glycoclusters. Such libraries are intended to boost the design of potential therapeutic anti-infectious agents targeting Pseudomonas aeruginosa, which is responsible for numerous diseases, mostly found in hospitals as major a cause of nosocomial infections. Dynamic combinatorial chemistry provides a rapid access to an equilibrating mixture of glycocluster candidates through the formation of reversible covalent bonds under thermodynamic control. Identifying each molecule in the complex mixture overcomes challenges due to the dynamic process. Selection of glycoclusters candidates was first realized on a model lectin (Concanavalin A, ConA). Home-made affinity nanocolumns, containing covalently immobilized ConA and have volumes in the microliter range, were used to separate DCLs of glycoclusters with respect to their specific lectin binding properties under buffered aqueous conditions. Miniaturization facilitates the inline coupling with MS detection in such purely aqueous and buffered conditions and reduces target protein consumption. Monolithic lectin-affinity columns prepared by immobilization of ConA were first characterized using a known ligand. The amount of active binding immobilized lectin is 61 ± 5 pmol on 8.5-cm length column. We demonstrated the ability of our approach to evaluate individual dissociation constants of species directly in the complex mixture. The concept was then successfully applied to the screening of DCLs of more complex glycoclusters to identify (by mass spectrometry) and rank the ligands (by relative breakthrough curve delay) according to their affinity for the immobilized lectin in a single experiment.
Collapse
Affiliation(s)
- Frédéric Jeanroy
- Institut des Sciences Analytiques, Université de Lyon, CNRS, Université Claude Bernard Lyon 1, UMR 5280, 5 rue de la Doua, Villeurbanne, F-69100, France
| | - Fanny Demontrond
- Institut de Chimie et Biochimie Moléculaires et Supramoléculaires, Laboratoire de Chimie Organique 2-Glycochimie, UMR 5246, CNRS, Université Claude Bernard Lyon 1, Université de Lyon, Villeurbanne, 69622, France
| | - François-Xavier Vidal
- Institut des Sciences Analytiques, Université de Lyon, CNRS, Université Claude Bernard Lyon 1, UMR 5280, 5 rue de la Doua, Villeurbanne, F-69100, France
| | - David Gueyrard
- Institut de Chimie et Biochimie Moléculaires et Supramoléculaires, Laboratoire de Chimie Organique 2-Glycochimie, UMR 5246, CNRS, Université Claude Bernard Lyon 1, Université de Lyon, Villeurbanne, 69622, France
| | - Sébastien Vidal
- Institut de Chimie et Biochimie Moléculaires et Supramoléculaires, Laboratoire de Chimie Organique 2-Glycochimie, UMR 5246, CNRS, Université Claude Bernard Lyon 1, Université de Lyon, Villeurbanne, 69622, France; Institut de Chimie des Substances Naturelles, CNRS, Université Paris-Saclay, UPR 2301, Gif-sur-Yvette, 91198, France
| | - Claire Demesmay
- Institut des Sciences Analytiques, Université de Lyon, CNRS, Université Claude Bernard Lyon 1, UMR 5280, 5 rue de la Doua, Villeurbanne, F-69100, France
| | - Vincent Dugas
- Institut des Sciences Analytiques, Université de Lyon, CNRS, Université Claude Bernard Lyon 1, UMR 5280, 5 rue de la Doua, Villeurbanne, F-69100, France.
| |
Collapse
|
6
|
Ovbude ST, Tao P, Li Z, Hage DS. Characterization of binding by repaglinide and nateglinide with glycated human serum albumin using high-performance affinity microcolumns. J Sep Sci 2022; 45:4176-4186. [PMID: 36168862 PMCID: PMC10012256 DOI: 10.1002/jssc.202200686] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/23/2022] [Revised: 09/18/2022] [Accepted: 09/23/2022] [Indexed: 12/13/2022]
Abstract
High-performance affinity microcolumns were used to characterize binding by the anti-diabetic drugs repaglinide and nateglinide with normal and glycated forms of human serum albumin. The microcolumns contained only nmol amounts of protein and provided a detailed analysis of these drug interactions with good precision and in a matter of minutes per experiment. The overall binding by repaglinide to normal and glycated albumin fits a model with two types of binding sites: a set of one or two moderate-to-high affinity regions and a larger set of weaker regions with association equilibrium constants of ∼105 and 103 M-1 , respectively, at pH 7.4 and 37°C. Competition studies gave site-specific association constants for repaglinide and nateglinide at Sudlow site I of 4.2 × 104 and 5.0 × 104 M-1 for normal albumin, with a decrease of 26%-30% being seen for nateglinide with glycated albumin and no significant change being noted for repaglinide. At Sudlow site II, repaglinide and nateglinide had association constants for normal albumin of 6.1 × 104 and 7.1 × 105 M-1 , with glycated albumin giving an increase in the association constant at this site for repaglinide of 1.6- to 1.8-fold and a decrease for nateglinide of 51%-58%.
Collapse
Affiliation(s)
- Susan T Ovbude
- Department of Chemistry, University of Nebraska-Lincoln, Lincoln, Nebraska, USA
| | - Pingyang Tao
- Department of Chemistry, University of Nebraska-Lincoln, Lincoln, Nebraska, USA
| | - Zhao Li
- Department of Chemistry, University of Nebraska-Lincoln, Lincoln, Nebraska, USA
| | - David S Hage
- Department of Chemistry, University of Nebraska-Lincoln, Lincoln, Nebraska, USA
| |
Collapse
|
7
|
Sharmeen S, Kyei I, Hatch A, Hage DS. Analysis of drug interactions with serum proteins and related binding agents by affinity capillary electrophoresis: A review. Electrophoresis 2022; 43:2302-2323. [PMID: 36250426 PMCID: PMC10098505 DOI: 10.1002/elps.202200191] [Citation(s) in RCA: 4] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/23/2022] [Revised: 09/17/2022] [Accepted: 10/05/2022] [Indexed: 11/06/2022]
Abstract
Biomolecules such as serum proteins can interact with drugs in the body and influence their pharmaceutical effects. Specific and precise methods that analyze these interactions are critical for drug development or monitoring and for diagnostic purposes. Affinity capillary electrophoresis (ACE) is one technique that can be used to examine the binding between drugs and serum proteins, or other agents found in serum or blood. This article will review the basic principles of ACE, along with related affinity-based capillary electrophoresis (CE) methods, and examine recent developments that have occurred in this field as related to the characterization of drug-protein interactions. An overview will be given of the various formats that can be used in ACE and CE for such work, including the relative advantages or weaknesses of each approach. Various applications of ACE and affinity-based CE methods for the analysis of drug interactions with serum proteins and other binding agents will also be presented. Applications of ACE and related techniques that will be discussed include drug interaction studies with serum agents, chiral drug separations employing serum proteins, and the use of CE in hybrid methods to characterize drug binding with serum proteins.
Collapse
Affiliation(s)
- Sadia Sharmeen
- Department of Chemistry, University of Nebraska-Lincoln, Lincoln, Nebraska, USA
| | - Isaac Kyei
- Department of Chemistry, University of Nebraska-Lincoln, Lincoln, Nebraska, USA
| | - Arden Hatch
- Department of Chemistry, University of Nebraska-Lincoln, Lincoln, Nebraska, USA
| | - David S Hage
- Department of Chemistry, University of Nebraska-Lincoln, Lincoln, Nebraska, USA
| |
Collapse
|
8
|
Wang L, Zhang W, Shao Y, Zhang D, Guo G, Wang X. Analytical methods for obtaining binding parameters of drug–protein interactions: A review. Anal Chim Acta 2022; 1219:340012. [DOI: 10.1016/j.aca.2022.340012] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/20/2021] [Revised: 05/25/2022] [Accepted: 05/27/2022] [Indexed: 11/30/2022]
|
9
|
Poddar S, Sharmeen S, Hage DS. Entrapment of Proteins Within Columns for High-Performance Affinity Chromatography. Methods Mol Biol 2022; 2466:205-227. [PMID: 35585320 DOI: 10.1007/978-1-0716-2176-9_14] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 06/15/2023]
Abstract
Entrapment is a noncovalent immobilization method that enables a large biological binding agent, such as a protein, to be put within a support without modifying the structure of the binding agent. This chapter describes an on-column entrapment method that can be used with proteins and HPLC-grade silica to prepare columns for high-performance liquid chromatography. In this method, a protein is trapped within a dihydrazide-activated silica support by using oxidized glycogen as a capping agent. This method allows the protein to be placed within the support in a soluble form and with little or no loss of activity. The approach and reagents needed for this method are described in this chapter, along with some applications reported for columns that have been made using on-column protein entrapment.
Collapse
Affiliation(s)
- Saumen Poddar
- Department of Chemistry, University of Nebraska-Lincoln, Lincoln, NE, USA
| | - Sadia Sharmeen
- Department of Chemistry, University of Nebraska-Lincoln, Lincoln, NE, USA
| | - David S Hage
- Department of Chemistry, University of Nebraska-Lincoln, Lincoln, NE, USA.
| |
Collapse
|
10
|
Gottardini A, Netter C, Dugas V, Demesmay C. Two Original Experimental Setups for Staircase Frontal Affinity Chromatography at the Miniaturized Scale. Anal Chem 2021; 93:16981-16986. [PMID: 34907771 DOI: 10.1021/acs.analchem.1c04772] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/06/2023]
Abstract
Frontal affinity chromatography is a powerful, underappreciated technique for the qualitative (screening) and quantitative (Kd determination) evaluation of biological interactions. Its development has been previously hampered by its sample consumption, limited throughput, and lack of dedicated instrumentation especially at a miniaturized scale. This work describes two original experimental devices allowing nano-frontal affinity chromatography titrations (nano-FAC) to be automatically implemented in the time-saving staircase mode. The first nano-FAC system utilizes a capillary electrophoresis device (7100 CE Agilent system) in the pressurization mode with in situ UV detection. The second nano-FAC experimental setup implements a nano-LC device (Ultimate 3000 Thermo) modified with a 10-port valve equipped with two superloops (loop volume, 5 μL) operating alternatively and automatically in a single run. The benefits and drawbacks of each approach are exemplified using two model protein-ligand interactions (concanavalin A-mannose and concanavalin A-glucose). The two methods result in concordant dissociation constants (Kd) and number of active site (Bact) values, obtained in a fully automated manner, with low sample consumption and good throughput.
Collapse
Affiliation(s)
- Andrea Gottardini
- Université de Lyon, CNRS, Université Claude Bernard Lyon 1, Institut des Sciences Analytiques, UMR 5280, 5 Rue de la Doua, F-69100 Villeurbanne, France
| | - Claude Netter
- Thermo Fisher Scientific, 16 Avenue du Québec, BP 30210, Villebon sur Yvette FR-91941, Courtabœuf Cedex, France
| | - Vincent Dugas
- Université de Lyon, CNRS, Université Claude Bernard Lyon 1, Institut des Sciences Analytiques, UMR 5280, 5 Rue de la Doua, F-69100 Villeurbanne, France
| | - Claire Demesmay
- Université de Lyon, CNRS, Université Claude Bernard Lyon 1, Institut des Sciences Analytiques, UMR 5280, 5 Rue de la Doua, F-69100 Villeurbanne, France
| |
Collapse
|
11
|
Development of a multi-layering protein grafting process on miniaturized monolithic columns for weak affinity nano liquid chromatography application purposes. J Chromatogr A 2021; 1657:462567. [PMID: 34601258 DOI: 10.1016/j.chroma.2021.462567] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/03/2021] [Revised: 09/13/2021] [Accepted: 09/15/2021] [Indexed: 11/21/2022]
Abstract
Affinity chromatography is a powerful technique to identify and quantify weak ligand-protein interactions (Kd in the range of mM to 0.1µM). In some fields such as Fragment Based Drug Discovery, the detection of very weak affinities (mM) is of utmost importance since weak ligands can be good starting points for the conception of high affinity ligands. However, the identification of such weak ligands can be hampered by the limited bulk density of active target grafted onto the support. At the same time, downscaling the chromatographic column is of utmost interest when scarce and/or expensive proteins are targeted. In this context, we herein present a novel approach of protein immobilization to improve the bulk density of active protein grafted onto organic capillary monolithic columns. The proposed approach is based on the streptavidin-biotin interaction and consists of successive grafting steps of biotinylated target protein onto streptavidin layers through a multi-layering process. Concanavalin A was used as model protein. The study focuses on the optimization of the grafting conditions to maximize the amount of active protein during the multi-layering process and highlights the impact of the biotinylation ratio of the protein. It is demonstrated that a 3-layer grafting process allows to improve the bulk density of active sites by a 2-fold factor compared to a single layer. This improvement in protein density allows to increase the affinity range of this technique to the millimolar range.
Collapse
|
12
|
Enantioresolution and Binding Affinity Studies on Human Serum Albumin: Recent Applications and Trends. CHEMOSENSORS 2021. [DOI: 10.3390/chemosensors9110304] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 12/12/2022]
Abstract
The interaction between proteins and drugs or other bioactive compounds has been widely explored over the past years. Several methods for analysis of this phenomenon have been developed and improved. Nowadays, increasing attention is paid to innovative methods, such as high performance affinity liquid chromatography (HPALC) and affinity capillary electrophoresis (ACE), taking into account various advantages. Moreover, the development of separation methods for the analysis and resolution of chiral drugs has been an area of ongoing interest in analytical and medicinal chemistry research. In addition to bioaffinity binding studies, both HPALC and ACE al-low one to perform other type of analyses, namely, displacement studies and enantioseparation of racemic or enantiomeric mixtures. Actually, proteins used as chiral selectors in chromatographic and electrophoretic methods have unique enantioselective properties demonstrating suitability for the enantioseparation of a large variety of chiral drugs or other bioactive compounds. This review is mainly focused in chromatographic and electrophoretic methods using human serum albumin (HSA), the most abundant plasma protein, as chiral selector for binding affinity analysis and enantioresolution of drugs. For both analytical purposes, updated examples are presented to highlight recent applications and current trends.
Collapse
|
13
|
Bai Y, Fan Y, Ge G, Wang F. [Advances in chromatography in the study of drug-plasma protein interactions]. Se Pu 2021; 39:1077-1085. [PMID: 34505429 PMCID: PMC9404221 DOI: 10.3724/sp.j.1123.2021.06028] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/25/2022] Open
Abstract
小分子药物进入人体血液循环系统后与人血清白蛋白(HSA)、α1 -酸性糖蛋白(AGP)等血浆蛋白存在广泛的相互作用,这些相互作用深刻影响药物在体内的分布及其与靶标蛋白的结合,进而影响药物效应的发挥。深入探究药物与血浆蛋白间的相互作用对于候选药物的成药性优化、新药研发、联合用药的风险评控等意义重大。而发展高效、灵敏、准确的分析检测方法是开展药物-血浆蛋白相互作用研究的关键。近年来,色谱技术由于其高通量、高分离性能、高灵敏度等特点在该领域得到了广泛的应用,包括测定血浆蛋白翻译后修饰对药物结合的影响,多种药物的竞争性结合等。其中,高效亲和色谱(HPAC)和毛细管电泳(CE)应用最为广泛,能够通过多种分析方法获取结合常数、结合位点数、解离速率常数等相互作用信息。该文着重综述了HPAC和CE在药物-血浆蛋白相互作用研究中的常用策略及最新研究进展,包括HPAC中常用的前沿色谱法、竞争洗脱法、超快亲和提取法、峰值分析法和峰衰减分析法,以及CE中常用的亲和毛细管电泳法(ACE)和毛细管电泳前沿分析法(CE-FA)等。最后,该文还对当前色谱方法存在的不足进行了总结,并对色谱技术在药物-血浆蛋白相互作用研究领域的应用前景和发展方向进行了展望。
Collapse
Affiliation(s)
- Yu Bai
- School of Pharmacy, China Medical University, Shenyang 110122, China.,CAS Key Laboratory of Separation Sciences for Analytical Chemistry, Dalian Institute of Chemical Physics, Chinese Academy of Sciences, Dalian 116023, China
| | - Yufan Fan
- Institute of Interdisciplinary Medicine, Shanghai University of Traditional Chinese Medicine, Shanghai 201203, China
| | - Guangbo Ge
- Institute of Interdisciplinary Medicine, Shanghai University of Traditional Chinese Medicine, Shanghai 201203, China
| | - Fangjun Wang
- CAS Key Laboratory of Separation Sciences for Analytical Chemistry, Dalian Institute of Chemical Physics, Chinese Academy of Sciences, Dalian 116023, China
| |
Collapse
|
14
|
Zhang C, Schumacher KN, Dodds ED, Hage DS. Glycoprotein analysis using lectin microcolumns and capillary electrophoresis: Characterization of alpha 1-acid glycoprotein by combined separation methods. J Chromatogr B Analyt Technol Biomed Life Sci 2021; 1179:122855. [PMID: 34274643 DOI: 10.1016/j.jchromb.2021.122855] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/29/2020] [Revised: 07/02/2021] [Accepted: 07/05/2021] [Indexed: 11/17/2022]
Abstract
Separations based on combinations of 2.1 mm I.D. high-performance affinity microcolumns and capillary electrophoresis were developed and used to characterize the glycoforms of an intact glycoprotein. Human alpha1-acid glycoprotein (AGP) was used as a model analyte due to its heterogeneous glycosylation resulting from variations in its degree of branching, fucosylation, and number of sialic acids. Three separation formats were examined based on microcolumns that contained the lectins concanavalin A (Con A) or Aleuria aurantia lectin (AAL). These microcolumns were used with one another or in combination with capillary electrophoresis. N-Glycan analysis of the non-retained and retained AGP fractions was carried out by using PNGase F digestion and nanoflow electrospray ionization mass spectrometry. Con A microcolumns were found to selectively enrich AGP that contained bi-antennary N-glycans, while AAL microcolumns retained AGP with fucose-containing N-glycans. Results from these separation methods indicated that fucosylation of the N-linked glycans was more abundant when a high degree of branching was present in AGP. Sialic acid residues were more abundant when higher degrees of branching and more fucose residues were present in AGP. The separation and analysis methods that were developed could be used with relatively small amounts of AGP and can be adapted for use with other intact glycoproteins.
Collapse
Affiliation(s)
- Chenhua Zhang
- Department of Chemistry, University of Nebraska, Lincoln, NE 68588, USA
| | | | - Eric D Dodds
- Department of Chemistry, University of Nebraska, Lincoln, NE 68588, USA
| | - David S Hage
- Department of Chemistry, University of Nebraska, Lincoln, NE 68588, USA.
| |
Collapse
|
15
|
Characterization of drug binding with alpha 1-acid glycoprotein in clinical samples using ultrafast affinity extraction. J Chromatogr A 2021; 1649:462240. [PMID: 34034105 DOI: 10.1016/j.chroma.2021.462240] [Citation(s) in RCA: 7] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Key Words] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/08/2021] [Revised: 05/01/2021] [Accepted: 05/03/2021] [Indexed: 11/24/2022]
Abstract
Many drugs bind to serum transport proteins, which can affect both drug distribution and activity in the body. α1-Acid glycoprotein (AGP) is a key transport protein for basic and neutral drugs. Both elevated levels and altered glycosylation patterns of AGP have been seen in clinical conditions such as systemic lupus erythematosus (SLE). This study developed, optimized, and used the method of ultrafast affinity extraction (UAE) to examine whether these changes in AGP are associated with changes in the binding by some drugs to this transport protein. This approach used affinity microcolumns to capture and measure, in serum, the free fractions of several drugs known to bind AGP. These measurements were made with pooled normal control serum and serum samples from individuals with SLE. Immunoaffinity chromatography was used to obtain the content of AGP and HSA in these samples, and CE was used to examine the glycoform pattern for AGP in each serum sample. The free drug fractions measured for normal control serum ranged from 3.5 to 29.1%, in agreement with the results of ultrafiltration, and provided binding constants of ~105-106 M-1 for the given drugs with AGP at 37⁰C. Analysis of a screening set of SLE serum samples by UAE gave decreased free fractions (relative change, 12-55%) vs normal serum when spiked with the same types and amounts of drugs. These changes were related in some cases to AGP content, with some SLE samples having AGP levels 1.3- to 2.1-fold above the upper end of the normal range. In other cases, the changes in free fractions appeared to be linked to alterations in the glycoforms and binding constants of AGP, with some affinities differing by 1.2- to 1.5-fold vs normal AGP. This approach can be employed with other solute-protein systems and to investigate binding by other drugs or transport proteins directly in clinical samples.
Collapse
|
16
|
Ovbude ST, Tao P, Li Z, Hage DS. High-Performance affinity chromatographic studies of repaglinide and nateglinide interactions with normal and glyoxal- or methylglyoxal-modified human albumin serum. J Pharm Biomed Anal 2021; 201:114097. [PMID: 33933705 DOI: 10.1016/j.jpba.2021.114097] [Citation(s) in RCA: 6] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/18/2021] [Revised: 04/17/2021] [Accepted: 04/19/2021] [Indexed: 11/16/2022]
Abstract
During diabetes human serum albumin (HSA), an important drug transport protein, can be modified by agents such as glyoxal (Go) and methylglyoxal (MGo) to form advanced glycation end-products. High-performance affinity microcolumns and zonal elution competition studies were used to compare interactions by the anti-diabetic drugs repaglinide and nateglinide with normal and Go- or MGo-modified HSA at Sudlow sites I and II of this protein. Both drugs had their strongest binding at Sudlow site II for the normal and modified forms of HSA. The association equilibrium constants at this site for repaglinide and nateglinide with normal HSA were 6.1 (± 0.2) × 104 M-1 and 7.1 (± 0.8) × 105 M-1, respectively, at pH 7.4 and 37⁰C; these values increased by up to 3.6-fold for repaglinide and decreased by up to 45-55 % for nateglinide when HSA was modified by Go or MGo at levels seen in prediabetes or diabetes. Both drugs were also found to bind at Sudlow site I, with association equilibrium constants at this site on normal HSA of 4.2 (± 0.3) × 104 M-1 for repaglinide and 5.0 (± 0.1) × 104 M-1 for nateglinide. The binding strength for repaglinide at Sudlow site I increased by 1.3- to 1.7-fold with the Go-modified HSA and decreased slightly (i.e., up to 19 %) for the MGo-modified HSA, while nateglinide showed only a small or insignificant change in binding with the same modified HSA samples. These results indicated that binding by repaglinide and nateglinide with HSA can be altered significantly by modification of this protein with Go or MGo, making these modifications of potential interest in the treatment of patients with these drugs during diabetes.
Collapse
Affiliation(s)
- Susan T Ovbude
- Chemistry Department, University of Nebraska, Lincoln, NE, 68588, USA
| | - Pingyang Tao
- Chemistry Department, University of Nebraska, Lincoln, NE, 68588, USA
| | - Zhao Li
- Chemistry Department, University of Nebraska, Lincoln, NE, 68588, USA
| | - David S Hage
- Chemistry Department, University of Nebraska, Lincoln, NE, 68588, USA.
| |
Collapse
|
17
|
Rodriguez EL, Poddar S, Iftekhar S, Suh K, Woolfork AG, Ovbude S, Pekarek A, Walters M, Lott S, Hage DS. Affinity chromatography: A review of trends and developments over the past 50 years. J Chromatogr B Analyt Technol Biomed Life Sci 2020; 1157:122332. [PMID: 32871378 PMCID: PMC7584770 DOI: 10.1016/j.jchromb.2020.122332] [Citation(s) in RCA: 62] [Impact Index Per Article: 15.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/06/2020] [Revised: 08/08/2020] [Accepted: 08/12/2020] [Indexed: 12/16/2022]
Abstract
The field of affinity chromatography, which employs a biologically-related agent as the stationary phase, has seen significant growth since the modern era of this method began in 1968. This review examines the major developments and trends that have occurred in this technique over the past five decades. The basic principles and history of this area are first discussed. This is followed by an overview of the various supports, immobilization strategies, and types of binding agents that have been used in this field. The general types of applications and fields of use that have appeared for affinity chromatography are also considered. A survey of the literature is used to identify major trends in these topics and important areas of use for affinity chromatography in the separation, analysis, or characterization of chemicals and biochemicals.
Collapse
Affiliation(s)
| | - Saumen Poddar
- Department of Chemistry, University of Nebraska, Lincoln, NE 68588, USA
| | - Sazia Iftekhar
- Department of Chemistry, University of Nebraska, Lincoln, NE 68588, USA
| | - Kyungah Suh
- Department of Chemistry, University of Nebraska, Lincoln, NE 68588, USA
| | - Ashley G Woolfork
- Department of Chemistry, University of Nebraska, Lincoln, NE 68588, USA
| | - Susan Ovbude
- Department of Chemistry, University of Nebraska, Lincoln, NE 68588, USA
| | - Allegra Pekarek
- Department of Chemistry, University of Nebraska, Lincoln, NE 68588, USA
| | - Morgan Walters
- Department of Chemistry, University of Nebraska, Lincoln, NE 68588, USA
| | - Shae Lott
- Department of Chemistry, University of Nebraska, Lincoln, NE 68588, USA
| | - David S Hage
- Department of Chemistry, University of Nebraska, Lincoln, NE 68588, USA.
| |
Collapse
|
18
|
Bag S, Rauwolf S, Suyetin M, Schwaminger SP, Wenzel W, Berensmeier S. Buffer Influence on the Amino Acid Silica Interaction. Chemphyschem 2020; 21:2347-2356. [PMID: 32794279 PMCID: PMC7702087 DOI: 10.1002/cphc.202000572] [Citation(s) in RCA: 9] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/04/2020] [Revised: 08/11/2020] [Indexed: 12/11/2022]
Abstract
Protein-surface interactions are exploited in various processes in life sciences and biotechnology. Many of such processes are performed in presence of a buffer system, which is generally believed to have an influence on the protein-surface interaction but is rarely investigated systematically. Combining experimental and theoretical methodologies, we herein demonstrate the strong influence of the buffer type on protein-surface interactions. Using state of the art chromatographic experiments, we measure the interaction between individual amino acids and silica, as a reference to understand protein-surface interactions. Among all the 20 proteinogenic amino acids studied, we found that arginine (R) and lysine (K) bind most strongly to silica, a finding validated by free energy calculations. We further measured the binding of R and K at different pH in presence of two different buffers, MOPS (3-(N-morpholino)propanesulfonic acid) and TRIS (tris(hydroxymethyl)aminomethane), and find dramatically different behavior. In presence of TRIS, the binding affinity of R/K increases with pH, whereas we observe an opposite trend for MOPS. These results can be understood using a multiscale modelling framework combining molecular dynamics simulation and Langmuir adsorption model. The modelling approach helps to optimize buffer conditions in various fields like biosensors, drug delivery or bio separation engineering prior to the experiment.
Collapse
Affiliation(s)
- Saientan Bag
- Institute of Nanotechnology (INT)Karlsruhe Institute of Technology (KIT)KarlsruheGermany
| | - Stefan Rauwolf
- Bioseparation Engineering GroupDepartment of Mechanical EngineeringTechnical University of Munich(TUM)GarchingGermany
| | - Mikhail Suyetin
- Institute of Nanotechnology (INT)Karlsruhe Institute of Technology (KIT)KarlsruheGermany
| | - Sebastian P. Schwaminger
- Bioseparation Engineering GroupDepartment of Mechanical EngineeringTechnical University of Munich(TUM)GarchingGermany
| | - Wolfgang Wenzel
- Institute of Nanotechnology (INT)Karlsruhe Institute of Technology (KIT)KarlsruheGermany
| | - Sonja Berensmeier
- Bioseparation Engineering GroupDepartment of Mechanical EngineeringTechnical University of Munich(TUM)GarchingGermany
| |
Collapse
|
19
|
Lecas L, Dugas V, Demesmay C. Affinity Chromatography: A Powerful Tool in Drug Discovery for Investigating Ligand/membrane Protein Interactions. SEPARATION & PURIFICATION REVIEWS 2020. [DOI: 10.1080/15422119.2020.1749852] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 12/31/2022]
Affiliation(s)
- Lucile Lecas
- Institut Des Sciences Analytiques, Université De Lyon, Institut des Sciences Analytiques (UMR 5280-CNRS, UCBLyon 1), 5 rue de la Doua, 69100 Villeurbanne, France
| | - Vincent Dugas
- Institut Des Sciences Analytiques, Université De Lyon, Institut des Sciences Analytiques (UMR 5280-CNRS, UCBLyon 1), 5 rue de la Doua, 69100 Villeurbanne, France
| | - Claire Demesmay
- Institut Des Sciences Analytiques, Université De Lyon, Institut des Sciences Analytiques (UMR 5280-CNRS, UCBLyon 1), 5 rue de la Doua, 69100 Villeurbanne, France
| |
Collapse
|
20
|
de Moraes MC, Cardoso CL, Cass QB. Solid-Supported Proteins in the Liquid Chromatography Domain to Probe Ligand-Target Interactions. Front Chem 2019; 7:752. [PMID: 31803714 PMCID: PMC6873629 DOI: 10.3389/fchem.2019.00752] [Citation(s) in RCA: 16] [Impact Index Per Article: 3.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/10/2019] [Accepted: 10/21/2019] [Indexed: 12/11/2022] Open
Abstract
Ligand-target interactions play a central role in drug discovery processes because these interactions are crucial in biological systems. Small molecules-proteins interactions can regulate and modulate protein function and activity through conformational changes. Therefore, bioanalytical tools to screen new ligands have focused mainly on probing ligand-target interactions. These interactions have been evaluated by using solid-supported proteins, which provide advantages like increased protein stability and easier protein extraction from the reaction medium, which enables protein reuse. In some specific approaches, precisely in the ligand fishing assay, the bioanalytical method allows the ligands to be directly isolated from complex mixtures, including combinatorial libraries and natural products extracts without prior purification or fractionation steps. Most of these screening assays are based on liquid chromatography separation, and the binding events can be monitored through on-line or off-line methods. In the on-line approaches, solid supports containing the immobilized biological target are used as chromatographic columns most of the time. Several terms have been used to refer to such approaches, such as weak affinity chromatography, high-performance affinity chromatography, on-flow activity assays, and high-performance liquid affinity chromatography. On the other hand, in the off-line approaches, the binding event occurs outside the liquid chromatography system and may encompass affinity and activity-based assays in which the biological target is immobilized on magnetic particles or monolithic silica, among others. After the incubation step, the supernatant or the eluate from the binding assay is analyzed by liquid chromatography coupled to various detectors. Regardless of the selected bioanalytical approach, the use of solid supported proteins has significantly contributed to the development of automated and reliable screening methods that enable ligands to be isolated and characterized in complex matrixes without purification, thereby reducing costs and avoiding time-laborious steps. This review provides a critical overview of recently developed assays.
Collapse
Affiliation(s)
- Marcela Cristina de Moraes
- Laboratório SINCROMA, Instituto de Química, Departamento de Química Orgânica, Universidade Federal Fluminense, Niterói, Brazil
| | - Carmen Lucia Cardoso
- Grupo de Cromatografia de Bioafinidade e Produtos Naturais, Departamento de Química, Faculdade de Filosofia, Ciências e Letras de Ribeirão Preto, Universidade de São Paulo, Ribeirão Preto, Brazil
| | - Quezia Bezerra Cass
- Separare, Departamento de Química, Universidade Federal de São Carlos, São Carlos, Brazil
| |
Collapse
|
21
|
Iftekhar S, Ovbude ST, Hage DS. Kinetic Analysis by Affinity Chromatography. Front Chem 2019; 7:673. [PMID: 31681727 PMCID: PMC6813734 DOI: 10.3389/fchem.2019.00673] [Citation(s) in RCA: 11] [Impact Index Per Article: 2.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/09/2019] [Accepted: 09/25/2019] [Indexed: 12/24/2022] Open
Abstract
Important information on chemical processes in living systems can be obtained by the rates at which these biological interactions occur. This review will discuss several techniques based on traditional and high-performance affinity chromatography that may be used to examine the kinetics of biological reactions. These methods include band-broadening measurements, techniques for peak fitting, split-peak analysis, peak decay studies, and ultrafast affinity extraction. The general principles and theory of each method, as applied to the determination of rate constants, will be discussed. The applications of each approach, along with its advantages and limitations, will also be considered.
Collapse
Affiliation(s)
- Sazia Iftekhar
- Department of Chemistry, University of Nebraska-Lincoln, Lincoln, NE, United States
| | - Susan T Ovbude
- Department of Chemistry, University of Nebraska-Lincoln, Lincoln, NE, United States
| | - David S Hage
- Department of Chemistry, University of Nebraska-Lincoln, Lincoln, NE, United States
| |
Collapse
|
22
|
Development of a microcolumn one-site immunometric assay for a protein biomarker: Analysis of alpha 1-acid glycoprotein. J Chromatogr A 2019; 1610:460558. [PMID: 31564560 DOI: 10.1016/j.chroma.2019.460558] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/30/2019] [Revised: 09/16/2019] [Accepted: 09/19/2019] [Indexed: 12/26/2022]
Abstract
A one-site immunometric assay based on affinity microcolumns was developed for the analysis of alpha1-acid glycoprotein (AGP) as a model protein biomarker. In this assay, a sample containing AGP was incubated with an excess amount of a labeled binding agent, such as fluorescein-labeled anti-AGP antibodies or Fab fragments. The excess binding agent was removed by passing this mixture through a microcolumn that contained an immobilized form of AGP, while the signal was measured for the binding agent-AGP complex in the non-retained fraction. Theoretical and practical factors were both considered in selecting the concentration of labeled binding agent, the incubation time of this agent with the sample, and the application conditions for this mixture onto the microcolumn. The effects of using various labeling methods and intact antibodies vs Fab fragments were also considered. The final assay was performed with fluorescein-labeled anti-AGP antibodies and a 2.1 mm i.d. × 1.0 cm AGP microcolumn operated at 0.30 mL min-1. This method required only 1 µL of serum or plasma, had a detection limit of 0.63 nM AGP, and gave a potential throughput of 2 min per sample. This assay was used to measure AGP in normal serum and plasma from patients with systemic lupus erythematosus, giving good agreement with the literature and a reference method. The same approach and guidelines can be used to create assays for other protein biomarkers by changing the labeled binding agent and immobilized protein within the microcolumn.
Collapse
|
23
|
Tsopelas F, Tsantili-Kakoulidou A. Advances with weak affinity chromatography for fragment screening. Expert Opin Drug Discov 2019; 14:1125-1135. [DOI: 10.1080/17460441.2019.1648425] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/22/2022]
Affiliation(s)
- Fotios Tsopelas
- Laboratory of Inorganic and Analytical Chemistry, School of Chemical Engineering, National Technical University of Athens, Athens, Greece
| | | |
Collapse
|
24
|
Development of a new in-line coupling of a miniaturized boronate affinity monolithic column with reversed-phase silica monolithic capillary column for analysis of cis-diol-containing nucleoside compounds. J Chromatogr A 2019; 1597:209-213. [DOI: 10.1016/j.chroma.2019.04.002] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/29/2019] [Revised: 04/01/2019] [Accepted: 04/02/2019] [Indexed: 12/27/2022]
|
25
|
Application of biomimetic HPLC to estimate in vivo behavior of early drug discovery compounds. FUTURE DRUG DISCOVERY 2019. [DOI: 10.4155/fdd-2019-0004] [Citation(s) in RCA: 15] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/07/2023] Open
Abstract
Characterizing the properties of large numbers of compounds and estimating their potential absorption, distribution, metabolism and elimination properties are important early stages in the process of drug discovery and help to reduce later stage attrition. The chromatographic separation principles using stationary phases that contain proteins and phospholipids are more suitable for compound characterization and estimation of the pharmacokinetic properties than the traditional octanol/water partition coefficient. This technology, when standardized, enables the prediction of in vivo behavior and the selection of compounds with the best potential, thus reducing the number of animal experiments. Chromatography may be involved more widely in the future to measure kinetic aspects of compounds’ binding to proteins and receptors which would enable designing compounds that require a lower frequency of doses and have more predictable pharmacokinetic profiles.
Collapse
|
26
|
Vargas-Badilla J, Poddar S, Azaria S, Zhang C, Hage DS. Optimization of protein entrapment in affinity microcolumns using hydrazide-activated silica and glycogen as a capping agent. J Chromatogr B Analyt Technol Biomed Life Sci 2019; 1121:1-8. [PMID: 31079009 DOI: 10.1016/j.jchromb.2019.05.004] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/30/2019] [Revised: 04/16/2019] [Accepted: 05/03/2019] [Indexed: 01/01/2023]
Abstract
Several approaches were compared for the entrapment of proteins within hydrazide-activated silica for use in affinity microcolumns and high performance affinity chromatography. Human serum albumin (HSA) and concanavalin A (Con A) were used as model proteins for this work. Items considered in this study included the role played by the solution volume, amount of added protein, and use of slurry vs. on-column entrapment on the levels of solute retention and extent of protein immobilization that could be obtained by means of entrapment. The levels of retention and protein immobilization were evaluated by injecting warfarin or 4-methylumbellipheryl α-D-mannopyranoside as solutes with known binding properties for HSA or Con A. Altering both the solution volume and amount of added protein led to an increase of up to 17-fold in the extent of protein immobilization for HSA in slurry-based entrapment; on-column entrapment provided an additional 3.6-fold increase in protein content vs. the optimized slurry method. Similar general trends were seen for Con A. The protein contents obtained by entrapment for HSA or Con A (i.e., up to ~87 and 46 mg/g silica, respectively) were comparable to or higher than levels reported for the covalent immobilization of these proteins onto silica. The retention of warfarin on the entrapped HSA was at least 1.7-fold higher than has been obtained under comparable support and mobile phase conditions when using covalent immobilization. These results indicated that entrapment can be an attractive alternative to covalent immobilization for proteins such as HSA and Con A, with this approach serving as a potential means for obtaining good solute binding and retention in work with affinity microcolumns or related microscale devices.
Collapse
Affiliation(s)
- John Vargas-Badilla
- Chemistry Department, University of Nebraska-Lincoln, Lincoln, NE 68588, USA
| | - Saumen Poddar
- Chemistry Department, University of Nebraska-Lincoln, Lincoln, NE 68588, USA
| | - Shiden Azaria
- Chemistry Department, University of Nebraska-Lincoln, Lincoln, NE 68588, USA
| | - Chenhua Zhang
- Chemistry Department, University of Nebraska-Lincoln, Lincoln, NE 68588, USA
| | - David S Hage
- Chemistry Department, University of Nebraska-Lincoln, Lincoln, NE 68588, USA.
| |
Collapse
|
27
|
Tao P, Li Z, Matsuda R, Hage DS. Chromatographic studies of chlorpropamide interactions with normal and glycated human serum albumin based on affinity microcolumns. J Chromatogr B Analyt Technol Biomed Life Sci 2018; 1097-1098:64-73. [PMID: 30205233 DOI: 10.1016/j.jchromb.2018.09.001] [Citation(s) in RCA: 14] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/26/2018] [Revised: 08/30/2018] [Accepted: 09/01/2018] [Indexed: 01/02/2023]
Abstract
Sulfonylurea drugs have significant binding to proteins in blood, with most of this binding believed to occur with human serum albumin (HSA). High performance affinity chromatography and affinity microcolumns containing immobilized HSA were used to investigate binding by the sulfonylurea drug chlorpropamide to normal HSA and glycated HSA, which is a modified form of HSA that has an increased serum concentration in diabetes. Experiments employing frontal analysis indicated that the binding by chlorpropamide gave a good fit to a two-site model for both normal HSA and glycated HSA samples that were representative of controlled or advanced diabetes. These interactions involved a set of moderate-to-high affinity sites and a set of lower affinity sites, with binding constants in the range of 6.2-9.9 × 104 M-1 and 0.18-0.57 × 104 M-1, respectively, at pH 7.4 and 37 °C. Competition studies utilizing a zonal elution format demonstrated that chlorpropamide could interact at both Sudlow sites I and II of HSA, with affinities in the range expected for the moderate-to-high affinity sites of this drug. The affinity of chlorpropamide at Sudlow site I had a small increase of up to 1.2-fold when comparing the normal HSA and glycated HSA samples. Chlorpropamide gave a larger 1.4- to over 1.5-fold increase at Sudlow site II when the affinity of this drug was compared between normal HSA and the same samples of glycated HSA. These results were compared to those obtained previously with other sulfonylurea drugs to help determine how glycation can change the overall and site-selective binding strength of these drugs with HSA at levels of protein modification that are seen in patients with diabetes.
Collapse
Affiliation(s)
- Pingyang Tao
- Chemistry Department, University of Nebraska, Lincoln, NE 68588, USA
| | - Zhao Li
- Chemistry Department, University of Nebraska, Lincoln, NE 68588, USA
| | - Ryan Matsuda
- Chemistry Department, University of Nebraska, Lincoln, NE 68588, USA
| | - David S Hage
- Chemistry Department, University of Nebraska, Lincoln, NE 68588, USA.
| |
Collapse
|
28
|
|
29
|
Ma W, Yang L, He L. Overview of the detection methods for equilibrium dissociation constant KD of drug-receptor interaction. J Pharm Anal 2018; 8:147-152. [PMID: 29922482 PMCID: PMC6004624 DOI: 10.1016/j.jpha.2018.05.001] [Citation(s) in RCA: 51] [Impact Index Per Article: 8.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/03/2018] [Revised: 04/25/2018] [Accepted: 05/04/2018] [Indexed: 01/27/2023] Open
Abstract
Drug-receptor interaction plays an important role in a series of biological effects, such as cell proliferation, immune response, tumor metastasis, and drug delivery. Therefore, the research on drug-receptor interaction is growing rapidly. The equilibrium dissociation constant (KD) is the basic parameter to evaluate the binding property of the drug-receptor. Thus, a variety of analytical methods have been established to determine the KD values, including radioligand binding assay, surface plasmon resonance method, fluorescence energy resonance transfer method, affinity chromatography, and isothermal titration calorimetry. With the invention and innovation of new technology and analysis method, there is a deep exploration and comprehension about drug-receptor interaction. This review discusses the different methods of determining the KD values, and analyzes the applicability and the characteristic of each analytical method. Conclusively, the aim is to provide the guidance for researchers to utilize the most appropriate analytical tool to determine the KD values.
Collapse
Affiliation(s)
| | | | - Langchong He
- School of Pharmacy, Xi’an Jiaotong University Health Science Center, No. 76, Yanta West Street, Xi’an, Shaanxi Province 710061, PR China
| |
Collapse
|
30
|
Anguizola JA, Pfaunmiller EL, Milanuk ML, Hage DS. Peak decay analysis and biointeraction studies of immunoglobulin binding and dissociation on protein G affinity microcolumns. Methods 2018; 146:39-45. [PMID: 29608965 DOI: 10.1016/j.ymeth.2018.03.013] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/22/2018] [Revised: 03/13/2018] [Accepted: 03/23/2018] [Indexed: 01/21/2023] Open
Abstract
Protein G can be a valuable binding agent for antibodies and immunoglobulins in methods such as immunosensors, chromatographic-based immunoassays, and immunoaffinity chromatography. This report used the method of peak decay analysis along with frontal analysis and zonal elution studies to characterize the binding, elution and regeneration properties of affinity microcolumns that contained immobilized protein G. Frontal analysis was employed with rabbit immunoglobulin G (IgG) to characterize the binding capacity of these affinity microcolumns. Zonal elution experiments looking at the retained peaks for small injections of labeled rabbit IgG were used to optimize the column regeneration conditions. Peak decay analysis was then used to look at the effects of flow rate and elution pH on the release of several types of IgG from the protein G microcolumns. This approach made it possible to obtain detailed information on the use and behavior of such columns, as could be used in future work to optimize the capture or analysis of IgG and antibodies by such devices. The same approach and tools that were used in this report could also be adapted for work with affinity columns that make use of other supports, binding agents or targets.
Collapse
Affiliation(s)
| | | | - Mitchell L Milanuk
- Department of Chemistry, University of Nebraska-Lincoln, Lincoln, NE, USA
| | - David S Hage
- Department of Chemistry, University of Nebraska-Lincoln, Lincoln, NE, USA
| |
Collapse
|
31
|
Beeram SR, Zheng X, Suh K, Hage DS. Characterization of solution-phase drug-protein interactions by ultrafast affinity extraction. Methods 2018; 146:46-57. [PMID: 29510250 DOI: 10.1016/j.ymeth.2018.02.021] [Citation(s) in RCA: 11] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/11/2017] [Revised: 02/17/2018] [Accepted: 02/22/2018] [Indexed: 11/25/2022] Open
Abstract
A number of tools based on high-performance affinity separations have been developed for studying drug-protein interactions. An example of one recent approach is ultrafast affinity extraction. This method has been employed to examine the free (or non-bound) fractions of drugs and other solutes in simple or complex samples that contain soluble binding agents. These free fractions have also been used to determine the binding constants and rate constants for the interactions of drugs with these soluble agents. This report describes the general principles of ultrafast affinity extraction and the experimental conditions under which it can be used to characterize such interactions. This method will be illustrated by utilizing data that have been obtained when using this approach to measure the binding and dissociation of various drugs with the serum transport proteins human serum albumin and alpha1-acid glycoprotein. A number of practical factors will be discussed that should be considered in the design and optimization of this approach for use with single-column or multi-column systems. Techniques will also be described for analyzing the resulting data for the determination of free fractions, rate constants and binding constants. In addition, the extension of this method to complex samples, such as clinical specimens, will be considered.
Collapse
Affiliation(s)
- Sandya R Beeram
- Department of Chemistry, University of Nebraska-Lincoln, Lincoln, NE 68588-0304, USA
| | - Xiwei Zheng
- Department of Chemistry, University of Nebraska-Lincoln, Lincoln, NE 68588-0304, USA
| | - Kyungah Suh
- Department of Chemistry, University of Nebraska-Lincoln, Lincoln, NE 68588-0304, USA
| | - David S Hage
- Department of Chemistry, University of Nebraska-Lincoln, Lincoln, NE 68588-0304, USA.
| |
Collapse
|
32
|
Ohlson S, Duong-Thi MD. Fragment screening for drug leads by weak affinity chromatography (WAC-MS). Methods 2018; 146:26-38. [PMID: 29378316 DOI: 10.1016/j.ymeth.2018.01.011] [Citation(s) in RCA: 16] [Impact Index Per Article: 2.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/26/2017] [Revised: 01/21/2018] [Accepted: 01/23/2018] [Indexed: 02/08/2023] Open
Abstract
Fragment-based drug discovery is an important tool for design of small molecule hit-to-lead compounds against various biological targets. Several approved drugs have been derived from an initial fragment screen and many such candidates are in various stages of clinical trials. Finding fragment hits, that are suitable for optimisation by medicinal chemists, is still a challenge as the binding between the small fragment and its target is weak in the range of mM to µM of Kd and irrelevant non-specific interactions are abundant in this area of transient interactions. Fortunately, there are methods that can study weak interactions quite efficiently of which NMR, surface plasmon resonance (SPR) and X-ray crystallography are the most prominent. Now, a new technology based on zonal affinity chromatography, weak affinity chromatography (WAC), has been introduced which has remedied many of the problems with other technologies. By combining WAC with mass spectrometry (WAC-MS), it is a powerful tool to identify binders quantitatively in terms of affinity and kinetics either from fragment libraries or from complex mixtures of biological extracts. As WAC-MS can be multiplexed by analysing mixtures of fragments (20-100 fragments) in one sample, this approach yields high throughput, where a whole library of e.g. >2000 fragments can be analysed quantitatively within a day. WAC-MS is easy to perform, where the robustness and quality of HPLC is fully utilized. This review will highlight the rationale behind the application of WAC-MS for fragment screening in drug discovery.
Collapse
Affiliation(s)
- Sten Ohlson
- School of Biological Sciences, Nanyang Technological University (NTU), Singapore 637551, Singapore.
| | - Minh-Dao Duong-Thi
- School of Biological Sciences, Nanyang Technological University (NTU), Singapore 637551, Singapore
| |
Collapse
|
33
|
Asmari M, Ratih R, Alhazmi HA, El Deeb S. Thermophoresis for characterizing biomolecular interaction. Methods 2018; 146:107-119. [PMID: 29438829 DOI: 10.1016/j.ymeth.2018.02.003] [Citation(s) in RCA: 68] [Impact Index Per Article: 11.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/30/2017] [Revised: 02/06/2018] [Accepted: 02/09/2018] [Indexed: 12/20/2022] Open
Abstract
The study of biomolecular interactions is crucial to get more insight into the biological system. The interactions of protein-protein, protein-nucleic acids, protein-sugars, nucleic acid-nucleic acids and protein-small molecules are supporting therapeutics and technological developments. Recently, the development in a large number of analytical techniques for characterizing biomolecular interactions reflect the promising research investments in this field. In this review, microscale thermophoresis technology (MST) is presented as an analytical technique for characterizing biomolecular interactions. Recent years have seen much progress and several applications established. MST is a powerful technique in quantitation of binding events based on the movement of molecules in microscopic temperature gradient. Simplicity, free solutions analysis, low sample volume, short analysis time, and immobilization free are the MST advantages over other competitive techniques. A wide range of studies in biomolecular interactions have been successfully carried out using MST, which tend to the versatility of the technique to use in screening binding events in order to save time, cost and obtained high data quality.
Collapse
Affiliation(s)
- Mufarreh Asmari
- Institute of Medicinal and Pharmaceutical Chemistry, TU Braunschweig, Beethovenstrasse 55, 38106 Braunschweig, Germany
| | - Ratih Ratih
- Institute of Medicinal and Pharmaceutical Chemistry, TU Braunschweig, Beethovenstrasse 55, 38106 Braunschweig, Germany
| | - Hassan A Alhazmi
- College of Pharmacy, Jazan University, P.O. Box 114, 45142 Jazan, Saudi Arabia
| | - Sami El Deeb
- Institute of Medicinal and Pharmaceutical Chemistry, TU Braunschweig, Beethovenstrasse 55, 38106 Braunschweig, Germany.
| |
Collapse
|
34
|
Zhang C, Rodriguez E, Bi C, Zheng X, Suresh D, Suh K, Li Z, Elsebaei F, Hage DS. High performance affinity chromatography and related separation methods for the analysis of biological and pharmaceutical agents. Analyst 2018; 143:374-391. [PMID: 29200216 PMCID: PMC5768458 DOI: 10.1039/c7an01469d] [Citation(s) in RCA: 38] [Impact Index Per Article: 6.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/17/2022]
Abstract
The last few decades have witnessed the development of many high-performance separation methods that use biologically related binding agents. The combination of HPLC with these binding agents results in a technique known as high performance affinity chromatography (HPAC). This review will discuss the general principles of HPAC and related techniques, with an emphasis on their use for the analysis of biological compounds and pharmaceutical agents. Various types of binding agents for these methods will be considered, including antibodies, immunoglobulin-binding proteins, aptamers, enzymes, lectins, transport proteins, lipids, and carbohydrates. Formats that will be discussed for these methods range from the direct detection of an analyte to indirect detection based on chromatographic immunoassays, as well as schemes based on analyte extraction or depletion, post-column detection, and multi-column systems. The use of biological agents in HPLC for chiral separations will also be considered, along with the use of HPAC as a tool to screen or study biological interactions. Various examples will be presented to illustrate these approaches and their applications in fields such as biochemistry, clinical chemistry, and pharmaceutical research.
Collapse
Affiliation(s)
- Chenhua Zhang
- Department of Chemistry, University of Nebraska, Lincoln, NE 68588-0304, USA.
| | | | | | | | | | | | | | | | | |
Collapse
|
35
|
Pirok BWJ, Gargano AFG, Schoenmakers PJ. Optimizing separations in online comprehensive two-dimensional liquid chromatography. J Sep Sci 2017; 41:68-98. [PMID: 29027363 PMCID: PMC5814945 DOI: 10.1002/jssc.201700863] [Citation(s) in RCA: 139] [Impact Index Per Article: 19.9] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/03/2017] [Revised: 09/21/2017] [Accepted: 09/21/2017] [Indexed: 12/16/2022]
Abstract
Online comprehensive two-dimensional liquid chromatography has become an attractive option for the analysis of complex nonvolatile samples found in various fields (e.g. environmental studies, food, life, and polymer sciences). Two-dimensional liquid chromatography complements the highly popular hyphenated systems that combine liquid chromatography with mass spectrometry. Two-dimensional liquid chromatography is also applied to the analysis of samples that are not compatible with mass spectrometry (e.g. high-molecular-weight polymers), providing important information on the distribution of the sample components along chemical dimensions (molecular weight, charge, lipophilicity, stereochemistry, etc.). Also, in comparison with conventional one-dimensional liquid chromatography, two-dimensional liquid chromatography provides a greater separation power (peak capacity). Because of the additional selectivity and higher peak capacity, the combination of two-dimensional liquid chromatography with mass spectrometry allows for simpler mixtures of compounds to be introduced in the ion source at any given time, improving quantitative analysis by reducing matrix effects. In this review, we summarize the rationale and principles of two-dimensional liquid chromatography experiments, describe advantages and disadvantages of combining different selectivities and discuss strategies to improve the quality of two-dimensional liquid chromatography separations.
Collapse
Affiliation(s)
- Bob W J Pirok
- University of Amsterdam, Analytical-Chemistry Group, van 't Hoff Institute for Molecular Sciences, Amsterdam, The Netherlands.,TI-COAST, Science Park, Amsterdam, The Netherlands
| | - Andrea F G Gargano
- University of Amsterdam, Analytical-Chemistry Group, van 't Hoff Institute for Molecular Sciences, Amsterdam, The Netherlands.,Vrije Universiteit Amsterdam, Department of Bioanalytical Chemistry, Amsterdam Institute for Molecules, Medicines and Systems, Amsterdam, The Netherlands
| | - Peter J Schoenmakers
- University of Amsterdam, Analytical-Chemistry Group, van 't Hoff Institute for Molecular Sciences, Amsterdam, The Netherlands
| |
Collapse
|
36
|
Ohlson S, Kaur J, Raida M, Niss U, Bengala T, Drum CL, Boehm B, Torres AR. Direct analysis – no sample preparation – of bioavailable cortisol in human plasma by weak affinity chromatography (WAC). J Chromatogr B Analyt Technol Biomed Life Sci 2017; 1061-1062:438-444. [DOI: 10.1016/j.jchromb.2017.07.035] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/13/2017] [Revised: 07/18/2017] [Accepted: 07/19/2017] [Indexed: 01/21/2023]
|
37
|
Vagias A, Sergelen K, Koynov K, Košovan P, Dostalek J, Jonas U, Knoll W, Fytas G. Diffusion and Permeation of Labeled IgG in Grafted Hydrogels. Macromolecules 2017. [DOI: 10.1021/acs.macromol.7b00514] [Citation(s) in RCA: 19] [Impact Index Per Article: 2.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/17/2022]
Affiliation(s)
- A. Vagias
- Max Planck Institute
for Polymer Research, Ackermannweg
10, 55128 Mainz, Germany
| | - K. Sergelen
- Biosensor
Technologies, AIT-Austrian Institute of Technology GmbH, Muthgasse
11, Wien 1190, Austria
- International
Graduate School on Bionanotechnology, University of Natural Resources
and Life Sciences, Nanyang Technological University, Singapore 639798
| | - K. Koynov
- Max Planck Institute
for Polymer Research, Ackermannweg
10, 55128 Mainz, Germany
| | - P. Košovan
- Department
of Physical and Macromolecular Chemistry, Faculty of Science, Charles University, Prague, Czech Republic
| | - J. Dostalek
- Biosensor
Technologies, AIT-Austrian Institute of Technology GmbH, Muthgasse
11, Wien 1190, Austria
| | - U. Jonas
- Macromolecular
Chemistry, Department Chemistry - Biology, University of Siegen, 57076 Siegen, Germany
| | - W. Knoll
- Biosensor
Technologies, AIT-Austrian Institute of Technology GmbH, Muthgasse
11, Wien 1190, Austria
| | - G. Fytas
- Max Planck Institute
for Polymer Research, Ackermannweg
10, 55128 Mainz, Germany
| |
Collapse
|
38
|
Hage DS. Analysis of Biological Interactions by Affinity Chromatography: Clinical and Pharmaceutical Applications. Clin Chem 2017; 63:1083-1093. [PMID: 28396561 DOI: 10.1373/clinchem.2016.262253] [Citation(s) in RCA: 24] [Impact Index Per Article: 3.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/13/2016] [Accepted: 12/02/2016] [Indexed: 12/27/2022]
Abstract
BACKGROUND The interactions between biochemical and chemical agents in the body are important in many clinical processes. Affinity chromatography and high-performance affinity chromatography (HPAC), in which a column contains an immobilized biologically related binding agent, are 2 methods that can be used to study these interactions. CONTENT This review presents various approaches that can be used in affinity chromatography and HPAC to characterize the strength or rate of a biological interaction, the number and types of sites that are involved in this process, and the interactions between multiple solutes for the same binding agent. A number of applications for these methods are examined, with an emphasis on recent developments and high-performance affinity methods. These applications include the use of these techniques for fundamental studies of biological interactions, high-throughput screening of drugs, work with modified proteins, tools for personalized medicine, and studies of drug-drug competition for a common binding agent. SUMMARY The wide range of formats and detection methods that can be used with affinity chromatography and HPAC for examining biological interactions makes these tools attractive for various clinical and pharmaceutical applications. Future directions in the development of small-scale columns and the coupling of these methods with other techniques, such as mass spectrometry or other separation methods, should continue to increase the flexibility and ease with which these approaches can be used in work involving clinical or pharmaceutical samples.
Collapse
Affiliation(s)
- David S Hage
- Department of Chemistry, University of Nebraska-Lincoln, Lincoln, NE.
| |
Collapse
|
39
|
Beeram S, Bi C, Zheng X, Hage DS. Chromatographic studies of drug interactions with alpha 1-acid glycoprotein by ultrafast affinity extraction and peak profiling. J Chromatogr A 2017; 1497:92-101. [PMID: 28366566 DOI: 10.1016/j.chroma.2017.03.056] [Citation(s) in RCA: 12] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/24/2016] [Revised: 03/11/2017] [Accepted: 03/21/2017] [Indexed: 12/28/2022]
Abstract
Interactions with serum proteins such as alpha1-acid glycoprotein (AGP) can have a significant effect on the behavior and pharmacokinetics of drugs. Ultrafast affinity extraction and peak profiling were used with AGP microcolumns to examine these processes for several model drugs (i.e., chlorpromazine, disopyramide, imipramine, lidocaine, propranolol and verapamil). The association equilibrium constants measured for these drugs with soluble AGP by ultrafast affinity extraction were in the general range of 104-106M-1 at pH 7.4 and 37°C and gave good agreement with literature values. Some of these values were dependent on the relative drug and protein concentrations that were present when using a single-site binding model; these results suggested a more complex mixed-mode interaction was actually present, which was also then used to analyze the data. The apparent dissociation rate constants that were obtained by ultrafast affinity extraction when using a single-site model varied from 0.14 to 7.0s-1 and were dependent on the relative drug and protein concentrations. Lower apparent dissociation rate constants were obtained by this approach as the relative amount of drug versus protein was decreased, with the results approaching those measured by peak profiling at low drug concentrations. This information should be useful in better understanding how these and other drugs interact with AGP in the circulation. In addition, the chromatographic approaches that were optimized and used in this report to examine these systems can be adapted for the analysis of other solute-protein interactions of biomedical interest.
Collapse
Affiliation(s)
- Sandya Beeram
- Department of Chemistry, University of Nebraska-Lincoln, Lincoln, NE 68588-0304, USA
| | - Cong Bi
- Department of Chemistry, University of Nebraska-Lincoln, Lincoln, NE 68588-0304, USA
| | - Xiwei Zheng
- Department of Chemistry, University of Nebraska-Lincoln, Lincoln, NE 68588-0304, USA
| | - David S Hage
- Department of Chemistry, University of Nebraska-Lincoln, Lincoln, NE 68588-0304, USA.
| |
Collapse
|
40
|
Singh P, Madhaiyan K, Duong-Thi MD, Dymock BW, Ohlson S. Analysis of Protein Target Interactions of Synthetic Mixtures by Affinity-LC/MS. SLAS DISCOVERY 2017; 22:440-446. [PMID: 28328315 DOI: 10.1177/2472555216687964] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 01/30/2023]
Abstract
Analysis of interactions between molecules is of fundamental importance in life science research. In this study, we applied weak affinity chromatography, based on high-performance liquid chromatography and mass spectrometry, as a powerful tool for direct analysis of the components of a chemical reaction mixture for their binding to a target protein. As a demonstration of the potential of this method, we analyzed the binding of the compounds of the reaction mixture to the chaperone heat shock protein 90 (Hsp90). It was possible to analyze quantitatively the binding of the components of the mixture to the target independently from each other without any preceding process such as purification. This feature has wide implications in biological sciences as crude mixtures, either natural or synthetic, can be analyzed directly for their possible binding to a target. This method could lead to savings in costs and labor through shortening chemical research project development time.
Collapse
Affiliation(s)
- Prachi Singh
- 1 School of Biological Sciences, Nanyang Technological University (NTU), Singapore
| | | | - Minh-Dao Duong-Thi
- 1 School of Biological Sciences, Nanyang Technological University (NTU), Singapore
| | - Brian W Dymock
- 2 Department of Pharmacy, National University of Singapore (NUS), Singapore
| | - Sten Ohlson
- 1 School of Biological Sciences, Nanyang Technological University (NTU), Singapore
| |
Collapse
|
41
|
Abstract
The development of separation methods for the analysis and resolution of chiral drugs and solutes has been an area of ongoing interest in pharmaceutical research. The use of proteins as chiral binding agents in high-performance liquid chromatography (HPLC) has been an approach that has received particular attention in such work. This report provides an overview of proteins that have been used as binding agents to create chiral stationary phases (CSPs) and in the use of chromatographic methods to study these materials and protein-based chiral separations. The supports and methods that have been employed to prepare protein-based CSPs will also be discussed and compared. Specific types of CSPs that are considered include those that employ serum transport proteins (e.g., human serum albumin, bovine serum albumin, and alpha1-acid glycoprotein), enzymes (e.g., penicillin G acylase, cellobiohydrolases, and α-chymotrypsin) or other types of proteins (e.g., ovomucoid, antibodies, and avidin or streptavidin). The properties and applications for each type of protein and CSP will also be discussed in terms of their use in chromatography and chiral separations.
Collapse
Affiliation(s)
- Cong Bi
- Department of Chemistry, University of Nebraska-Lincoln, Lincoln, NE 68588-0304, USA
| | - Xiwei Zheng
- Department of Chemistry, University of Nebraska-Lincoln, Lincoln, NE 68588-0304, USA
| | - Shiden Azaria
- Department of Chemistry, University of Nebraska-Lincoln, Lincoln, NE 68588-0304, USA
| | - Sandya Beeram
- Department of Chemistry, University of Nebraska-Lincoln, Lincoln, NE 68588-0304, USA
| | - Zhao Li
- Department of Chemistry, University of Nebraska-Lincoln, Lincoln, NE 68588-0304, USA
| | - David S. Hage
- Department of Chemistry, University of Nebraska-Lincoln, Lincoln, NE 68588-0304, USA
| |
Collapse
|
42
|
On-column entrapment of alpha1-acid glycoprotein for studies of drug-protein binding by high-performance affinity chromatography. Anal Bioanal Chem 2016; 408:5745-5756. [PMID: 27289464 DOI: 10.1007/s00216-016-9677-7] [Citation(s) in RCA: 12] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/02/2016] [Revised: 05/20/2016] [Accepted: 05/31/2016] [Indexed: 01/25/2023]
Abstract
An on-column approach for protein entrapment was developed to immobilize alpha1-acid glycoprotein (AGP) for drug-protein binding studies based on high-performance affinity chromatography. Soluble AGP was physically entrapped by using microcolumns that contained hydrazide-activated porous silica and by employing mildly oxidized glycogen as a capping agent. Three on-column entrapment methods were evaluated and compared to a previous slurry-based entrapment method. The final selected method was used to prepare 1.0 cm × 2.1 mm I.D. affinity microcolumns that contained up to 21 (±4) μg AGP and that could be used over the course of more than 150 sample applications. Frontal analysis and zonal elution studies were performed on these affinity microcolumns to examine the binding of various drugs with the entrapped AGP. Site-selective competition studies were also conducted for these drugs. The results showed good agreement with previous observations for these drug-protein systems and with binding constants that have been reported in the literature. The entrapment method developed in this study should be useful for future work in the area of personalized medicine and in the high-throughput screening of drug interactions with AGP or other proteins. Graphical abstract On-column protein entrapment using a hydrazide-activated support and oxidized glycogen as a capping agent.
Collapse
|
43
|
|
44
|
Bi C, Zheng X, Hage DS. Analysis of free drug fractions in serum by ultrafast affinity extraction and two-dimensional affinity chromatography using α1-acid glycoprotein microcolumns. J Chromatogr A 2016; 1432:49-57. [PMID: 26797422 DOI: 10.1016/j.chroma.2015.12.084] [Citation(s) in RCA: 13] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/02/2015] [Revised: 12/28/2015] [Accepted: 12/29/2015] [Indexed: 12/17/2022]
Abstract
In the circulatory system, many drugs are reversibly bound to serum proteins such as human serum albumin (HSA) and alpha1-acid glycoprotein (AGP), resulting in both free and protein-bound fractions for these drugs. This report examined the use of microcolumns containing immobilized AGP for the measurement of free drug fractions by ultrafast affinity extraction and a two-dimensional affinity system. Several drugs known to bind AGP were used as models to develop and evaluate this approach. Factors considered during the creation of this method included the retention of the drugs on the microcolumns, the injection flow rate, the microcolumn size, and the times at which a second AGP column was placed on-line with the microcolumn. The final system had residence times of only 110-830ms during sample passage through the AGP microcolumns and allowed free drug fractions to be determined within 10-20min when using only 3-10μL of sample per injection. This method was used to measure the free fractions of the model drugs at typical therapeutic levels in serum, giving good agreement with the results obtained by ultrafiltration. This approach was also used to estimate the binding constants for each drug with AGP in serum, even for drugs that had significant interactions with both AGP and HSA in such samples. These results indicated that AGP microcolumns could be used with ultrafast affinity extraction to measure free drug fractions in a label-free manner and to study the binding of drugs with AGP in complex samples such as serum.
Collapse
Affiliation(s)
- Cong Bi
- Department of Chemistry, University of Nebraska, Lincoln, NE 68588, USA
| | - Xiwei Zheng
- Department of Chemistry, University of Nebraska, Lincoln, NE 68588, USA
| | - David S Hage
- Department of Chemistry, University of Nebraska, Lincoln, NE 68588, USA.
| |
Collapse
|
45
|
Pfaunmiller EL, Anguizola JA, Milanuk ML, Carter N, Hage DS. Use of protein G microcolumns in chromatographic immunoassays: A comparison of competitive binding formats. J Chromatogr B Analyt Technol Biomed Life Sci 2016; 1021:91-100. [PMID: 26777776 DOI: 10.1016/j.jchromb.2015.12.055] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/18/2015] [Revised: 12/18/2015] [Accepted: 12/28/2015] [Indexed: 12/13/2022]
Abstract
Affinity microcolumns containing protein G were used as general platforms for creating chromatographic-based competitive binding immunoassays. Human serum albumin (HSA) was used as a model target for this work and HSA tagged with a near infrared fluorescent dye was utilized as the label. The protein G microcolumns were evaluated for use in several assay formats, including both solution-based and column-based competitive binding immunoassays and simultaneous or sequential injection formats. All of these methods were characterized by using the same amounts of labeled HSA and anti-HSA antibodies per sample, as chosen for the analysis of a protein target in the low-to-mid ng/mL range. The results were used to compare these formats in terms of their response, precision, limit of detection, and analysis time. All these methods gave detection limits in the range of 8-19ng/mL and precisions ranging from ±5% to ±10% when using an injection flow rate of 0.10mL/min. The column-based sequential injection immunoassay provided the best limit of detection and the greatest change in response at low target concentrations, while the solution-based simultaneous injection method had the broadest linear and dynamic ranges. These results provided valuable guidelines that can be employed to develop and extend the use of protein G microcolumns and these competitive binding formats to other protein biomarkers or biological agents of clinical or pharmaceutical interest.
Collapse
Affiliation(s)
| | | | - Mitchell L Milanuk
- Chemistry Department, University of Nebraska, Lincoln, NE, United States
| | - NaTasha Carter
- Chemistry Department, University of Nebraska, Lincoln, NE, United States
| | - David S Hage
- Chemistry Department, University of Nebraska, Lincoln, NE, United States.
| |
Collapse
|
46
|
Li Z, Beeram SR, Bi C, Suresh D, Zheng X, Hage DS. High-Performance Affinity Chromatography: Applications in Drug-Protein Binding Studies and Personalized Medicine. ADVANCES IN PROTEIN CHEMISTRY AND STRUCTURAL BIOLOGY 2015; 102:1-39. [PMID: 26827600 DOI: 10.1016/bs.apcsb.2015.09.007] [Citation(s) in RCA: 19] [Impact Index Per Article: 2.1] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 12/20/2022]
Abstract
The binding of drugs with proteins and other agents in serum is of interest in personalized medicine because this process can affect the dosage and action of drugs. The extent of this binding may also vary with a given disease state. These interactions may involve serum proteins, such as human serum albumin or α1-acid glycoprotein, or other agents, such as lipoproteins. High-performance affinity chromatography (HPAC) is a tool that has received increasing interest as a means for studying these interactions. This review discusses the general principles of HPAC and the various approaches that have been used in this technique to examine drug-protein binding and in work related to personalized medicine. These approaches include frontal analysis and zonal elution, as well as peak decay analysis, ultrafast affinity extraction, and chromatographic immunoassays. The operation of each method is described and examples of applications for these techniques are provided. The type of information that can be obtained by these methods is also discussed, as related to the analysis of drug-protein binding and the study of clinical or pharmaceutical samples.
Collapse
Affiliation(s)
- Zhao Li
- Department of Chemistry, University of Nebraska-Lincoln, Lincoln, Nebraska, USA
| | - Sandya R Beeram
- Department of Chemistry, University of Nebraska-Lincoln, Lincoln, Nebraska, USA
| | - Cong Bi
- Department of Chemistry, University of Nebraska-Lincoln, Lincoln, Nebraska, USA
| | - D Suresh
- Department of Chemistry, University of Nebraska-Lincoln, Lincoln, Nebraska, USA
| | - Xiwei Zheng
- Department of Chemistry, University of Nebraska-Lincoln, Lincoln, Nebraska, USA
| | - David S Hage
- Department of Chemistry, University of Nebraska-Lincoln, Lincoln, Nebraska, USA.
| |
Collapse
|
47
|
Matsuda R, Jobe D, Beyersdorf J, Hage DS. Analysis of drug-protein binding using on-line immunoextraction and high-performance affinity microcolumns: Studies with normal and glycated human serum albumin. J Chromatogr A 2015; 1416:112-20. [PMID: 26381571 PMCID: PMC4587353 DOI: 10.1016/j.chroma.2015.09.023] [Citation(s) in RCA: 14] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/24/2015] [Revised: 09/02/2015] [Accepted: 09/05/2015] [Indexed: 02/03/2023]
Abstract
A method combining on-line immunoextraction microcolumns with high-performance affinity chromatography (HPAC) was developed and tested for use in examining drug-protein interactions with normal or modified proteins. Normal human serum albumin (HSA) and glycated HSA were used as model proteins for this work. High-performance immunoextraction microcolumns with sizes of 1.0-2.0 cm × 2.1mm i.d. and containing anti-HSA polyclonal antibodies were developed and tested for their ability to bind normal HSA or glycated HSA. These microcolumns were able to extract up to 82-93% for either type of protein at 0.05-0.10 mL/min and had a binding capacity of 0.34-0.42 nmol HSA for a 1.0 cm × 2.1mm i.d. microcolumn. The immunoextraction microcolumns and their adsorbed proteins were tested for use in various approaches for drug binding studies. Frontal analysis was used with the adsorbed HSA/glycated HSA to measure the overall affinities of these proteins for the drugs warfarin and gliclazide, giving comparable values to those obtained previously using similar protein preparations that had been covalently immobilized within HPAC columns. Zonal elution competition studies with gliclazide were next performed to examine the specific interactions of this drug at Sudlow sites I and II of the adsorbed proteins. These results were also comparable to those noted in prior work with covalently immobilized samples of normal HSA or glycated HSA. These experiments indicated that drug-protein binding studies can be carried out by using on-line immunoextraction microcolumns with HPAC. The same method could be used in the future with clinical samples and other drugs or proteins of interest in pharmaceutical studies or biomedical research.
Collapse
Affiliation(s)
- Ryan Matsuda
- Department of Chemistry, University of Nebraska-Lincoln, Lincoln, NE 68588-0304, USA
| | - Donald Jobe
- Department of Chemistry, University of Nebraska-Lincoln, Lincoln, NE 68588-0304, USA
| | - Jared Beyersdorf
- Department of Chemistry, University of Nebraska-Lincoln, Lincoln, NE 68588-0304, USA
| | - David S Hage
- Department of Chemistry, University of Nebraska-Lincoln, Lincoln, NE 68588-0304, USA.
| |
Collapse
|
48
|
Analysis of free drug fractions in human serum by ultrafast affinity extraction and two-dimensional affinity chromatography. Anal Bioanal Chem 2015; 408:131-40. [PMID: 26462924 DOI: 10.1007/s00216-015-9082-7] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/19/2015] [Revised: 09/19/2015] [Accepted: 09/24/2015] [Indexed: 12/12/2022]
Abstract
Ultrafast affinity extraction and a two-dimensional high performance affinity chromatographic system were used to measure the free fractions for various drugs in serum and at typical therapeutic concentrations. Pooled samples of normal serum or serum from diabetic patients were utilized in this work. Several drug models (i.e., quinidine, diazepam, gliclazide, tolbutamide, and acetohexamide) were examined that represented a relatively wide range of therapeutic concentrations and affinities for human serum albumin (HSA). The two-dimensional system consisted of an HSA microcolumn for the extraction of a free drug fraction, followed by a larger HSA analytical column for the further separation and measurement of this fraction. Factors that were optimized in this method included the flow rates, column sizes, and column switching times that were employed. The final extraction times used for isolating the free drug fractions were 333-665 ms or less. The dissociation rate constants for several of the drugs with soluble HSA were measured during system optimization, giving results that agreed with reference values. In the final system, free drug fractions in the range of 0.7-9.5% were measured and gave good agreement with values that were determined by ultrafiltration. Association equilibrium constants or global affinities were also estimated by this approach for the drugs with soluble HSA. The results for the two-dimensional system were obtained in 5-10 min or less and required only 1-5 μL of serum per injection. The same approach could be adapted for work with other drugs and proteins in clinical samples or for biomedical research.
Collapse
|
49
|
Bi C, Beeram S, Li Z, Zheng X, Hage DS. Kinetic analysis of drug-protein interactions by affinity chromatography. DRUG DISCOVERY TODAY. TECHNOLOGIES 2015; 17:16-21. [PMID: 26724332 DOI: 10.1016/j.ddtec.2015.09.003] [Citation(s) in RCA: 12] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 05/29/2015] [Accepted: 09/14/2015] [Indexed: 10/23/2022]
Abstract
Information on the kinetics of drug-protein interactions is of crucial importance in drug discovery and development. Several methods based on affinity chromatography have been developed in recent years to examine the association and dissociation rates of these processes. These techniques include band-broadening measurements, the peak decay method, peak fitting methods, the split-peak method, and free fraction analysis. This review will examine the general principles and applications of these approaches and discuss their use in the characterization, screening and analysis of drug-protein interactions in the body.
Collapse
Affiliation(s)
- Cong Bi
- Department of Chemistry, University of Nebraska, Lincoln, NE 68588, USA
| | - Sandya Beeram
- Department of Chemistry, University of Nebraska, Lincoln, NE 68588, USA
| | - Zhao Li
- Department of Chemistry, University of Nebraska, Lincoln, NE 68588, USA
| | - Xiwei Zheng
- Department of Chemistry, University of Nebraska, Lincoln, NE 68588, USA
| | - David S Hage
- Department of Chemistry, University of Nebraska, Lincoln, NE 68588, USA.
| |
Collapse
|
50
|
Zheng X, Bi C, Li Z, Podariu M, Hage DS. Analytical methods for kinetic studies of biological interactions: A review. J Pharm Biomed Anal 2015; 113:163-80. [PMID: 25700721 PMCID: PMC4516701 DOI: 10.1016/j.jpba.2015.01.042] [Citation(s) in RCA: 46] [Impact Index Per Article: 5.1] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/09/2014] [Revised: 01/16/2015] [Accepted: 01/19/2015] [Indexed: 01/13/2023]
Abstract
The rates at which biological interactions occur can provide important information concerning the mechanism and behavior of these processes in living systems. This review discusses several analytical methods that can be used to examine the kinetics of biological interactions. These techniques include common or traditional methods such as stopped-flow analysis and surface plasmon resonance spectroscopy, as well as alternative methods based on affinity chromatography and capillary electrophoresis. The general principles and theory behind these approaches are examined, and it is shown how each technique can be utilized to provide information on the kinetics of biological interactions. Examples of applications are also given for each method. In addition, a discussion is provided on the relative advantages or potential limitations of each technique regarding its use in kinetic studies.
Collapse
Affiliation(s)
- Xiwei Zheng
- Department of Chemistry, University of Nebraska, Lincoln, NE 68588, USA
| | - Cong Bi
- Department of Chemistry, University of Nebraska, Lincoln, NE 68588, USA
| | - Zhao Li
- Department of Chemistry, University of Nebraska, Lincoln, NE 68588, USA
| | - Maria Podariu
- Department of Chemistry, University of Nebraska, Lincoln, NE 68588, USA
| | - David S Hage
- Department of Chemistry, University of Nebraska, Lincoln, NE 68588, USA.
| |
Collapse
|