1
|
Melo LMA, Souza KAO, Lopes JEB, Muñoz RAA, Costa JL, Dos Santos WTP. Electrochemical methods for the determination of acetaminophen in biological matrices: A critical review in the clinical field. Anal Chim Acta 2025; 1333:343243. [PMID: 39615920 DOI: 10.1016/j.aca.2024.343243] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/05/2024] [Revised: 08/31/2024] [Accepted: 09/12/2024] [Indexed: 12/10/2024]
Abstract
BACKGROUND Paracetamol or acetaminophen (APAP), or acetaminophen, is a widely used medication for pain relief and fever reduction due to its analgesic and antipyretic properties. However, excessive APAP consumption can lead to severe hepatotoxicity and nephrotoxicity, posing overdose risks. Consequently, the development of analytical methods for an accurate and rapid detection of APAP in biological matrices is of great interest in the health-related fields. Electrochemical methods have emerged as efficient, cost-effective, and sensitive tools for APAP detection in biological samples. In the light of the reported insights, this review examines critically diverse electrochemical methods for PAR detection in different biological matrices, including serum, urine, oral fluid, and sweat. RESULTS The claimed benefits of chemically-modified electrodes towards the selective determination of paracetamol in such complex sample matrices are discussed. On the other hand, the possible use of unmodified carbon-based electrodes combined with flow methods is highlighted as an alternative that can find relevance in the analysis of biological fluids suspected of PAR overdose occurring in the forensic scenario. Furthermore, the details regarding the distinct techniques and working electrodes for APAP determination are presented, compared and discussed in separate sections for each biological sample (serum, urine, and oral fluid). Another aspect herein debated is the selective determination of APAP in the presence of electroactive drugs naturally found in biological samples, as uric acid, and ascorbic acid, are evaluated. In addition, we have discussed and emphasized the significance of matrix selection to ensure precise results, especially in potential overdose scenarios. SIGNIFICANCE This review article provides a critical discussion on the development of electroanalytical methods for biological fluids, with relevance to the fields of clinical analysis and forensics.
Collapse
Affiliation(s)
- Larissa M A Melo
- Departamento de Química, Universidade Federal dos Vales do Jequitinhonha e Mucuri, Campus JK, 39100000, Diamantina, Minas Gerais, Brazil
| | - Karla A O Souza
- Faculdade de Ciências Médicas, Universidade Estadual de Campinas, 13083859, Campinas, São Paulo, Brazil; Centro de Informação e Assistência Toxicológica de Campinas, Universidade Estadual de Campinas, 13083859, Campinas, São Paulo, Brazil
| | - Jéssica E B Lopes
- Departamento de Farmácia, Universidade Federal dos Vales do Jequitinhonha e Mucuri, Campus JK, 39100000, Diamantina, Minas Gerais, Brazil
| | - Rodrigo A A Muñoz
- Instituto de Química, Universidade Federal de Uberlândia, 38400-902, Uberlândia, Minas Gerais, Brazil.
| | - Jose L Costa
- Centro de Informação e Assistência Toxicológica de Campinas, Universidade Estadual de Campinas, 13083859, Campinas, São Paulo, Brazil; Faculdade de Ciências Farmacêuticas, Universidade Estadual de Campinas, 13083859, Campinas, São Paulo, Brazil
| | - Wallans T P Dos Santos
- Departamento de Farmácia, Universidade Federal dos Vales do Jequitinhonha e Mucuri, Campus JK, 39100000, Diamantina, Minas Gerais, Brazil.
| |
Collapse
|
2
|
Zhang T, Zhu J, Xie M, Meng K, Yao G, Pan T, Gao M, Cheng H, Lin Y. Highly Sensitive Wearable Sensor Based on (001)-Orientated TiO 2 for Real-Time Electrochemical Detection of Dopamine, Tyrosine, and Paracetamol. SMALL (WEINHEIM AN DER BERGSTRASSE, GERMANY) 2024; 20:e2312238. [PMID: 38319031 DOI: 10.1002/smll.202312238] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 12/29/2023] [Revised: 01/22/2024] [Indexed: 02/07/2024]
Abstract
The concentration of dopamine (DA) and tyrosine (Tyr) reflects the condition of patients with Parkinson's disease, whereas moderate paracetamol (PA) can help relieve their pain. Therefore, real-time measurements of these bioanalytes have important clinical implications for patients with Parkinson's disease. However, previous sensors suffer from either limited sensitivity or complex fabrication and integration processes. This work introduces a simple and cost-effective method to prepare high-quality, flexible titanium dioxide (TiO2) thin films with highly reactive (001)-facets. The as-fabricated TiO2 film supported by a carbon cloth electrode (i.e., TiO2-CC) allows excellent electrochemical specificity and sensitivity to DA (1.390 µA µM-1 cm-2), Tyr (0.126 µA µM-1 cm-2), and PA (0.0841 µA µM-1 cm-2). More importantly, accurate DA concentration in varied pH conditions can be obtained by decoupling them within a single differential pulse voltammetry measurement without additional sensing units. The TiO2-CC electrochemical sensor can be integrated into a smart diaper to detect the trace amount of DA or an integrated skin-interfaced patch with microfluidic sampling and wireless transmission units for real-time detection of the sweat Try and PA concentration. The wearable sensor based on TiO2-CC prepared by facile manufacturing methods holds great potential in the daily health monitoring and care of patients with neurological disorders.
Collapse
Affiliation(s)
- Tianyao Zhang
- School of Material and Energy, University of Electronic Science and Technology of China, Chengdu, 610054, China
| | - Jia Zhu
- School of Material and Energy, University of Electronic Science and Technology of China, Chengdu, 610054, China
- Yangtze Delta Region Institute (Quzhou), University of Electronic Science and Technology of China, Quzhou, 324000, China
- Department of Engineering Science and Mechanics, The Pennsylvania State University, University Park, Pennsylvania, 16802, USA
| | - Maowen Xie
- School of Material and Energy, University of Electronic Science and Technology of China, Chengdu, 610054, China
| | - Ke Meng
- School of Material and Energy, University of Electronic Science and Technology of China, Chengdu, 610054, China
| | - Guang Yao
- School of Material and Energy, University of Electronic Science and Technology of China, Chengdu, 610054, China
| | - Taisong Pan
- School of Material and Energy, University of Electronic Science and Technology of China, Chengdu, 610054, China
| | - Min Gao
- School of Material and Energy, University of Electronic Science and Technology of China, Chengdu, 610054, China
| | - Huanyu Cheng
- Department of Engineering Science and Mechanics, The Pennsylvania State University, University Park, Pennsylvania, 16802, USA
| | - Yuan Lin
- School of Material and Energy, University of Electronic Science and Technology of China, Chengdu, 610054, China
- Medico-Engineering Cooperation on Applied Medicine Research Center, University of Electronics Science and Technology of China, Chengdu, 610054, China
| |
Collapse
|
3
|
Ahmed YM, Eldin MA, Galal A, Atta NF. Electrochemical sensor based on PEDOT/CNTs-graphene oxide for simultaneous determination of hazardous hydroquinone, catechol, and nitrite in real water samples. Sci Rep 2024; 14:5654. [PMID: 38454022 PMCID: PMC10920748 DOI: 10.1038/s41598-024-54683-9] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/19/2023] [Accepted: 02/15/2024] [Indexed: 03/09/2024] Open
Abstract
Hydroquinone (HQ), catechol (CC) and nitrite (NT) are considered aquatic environmental pollutants. They are highly toxic, harm humans' health, and damage the environment. Thus, in the present work we introduce a simple and efficient electrochemical sensor for determination of HQ, CC, and NT simultaneously in wastewater sample. The sensor is fabricated by modifying the surface of a glassy carbon electrode (GCE) by two successive thin films from poly(3,4-ethylenedioxythiophene) (PEDOT) and a mixture of carbon nanotubes-graphene oxide (CNT-GRO). Under optimized conditions the HQ, CC, and NT are successfully detected simultaneously in wastewater sample with changing their concentrations in the ranges (0.04 → 100 µM), (0.01 → 100 µM) and (0.05 → 120 µM), the detection limits are 8.5 nM, 3.8 nM and 6.1 nM, respectively. Good potential peak separations: 117 mV and 585 mV are obtained between the HQ-CC, and CC-NT. The sensor has an excellent catalytic capability toward the oxidation of HQ, CC, and NT due to good synergism between its composite components: PEDOT, GRO and CNTs. The features of the sensor are large active surface area, good electrical conductivity, perfect storage stability, good reproducibility, anti-interference capability and accepted recovery rate for HQ, CC, and NT determination in wastewater sample.
Collapse
Affiliation(s)
- Yousef M Ahmed
- Chemistry Department, Faculty of Science, Cairo University, Giza, 12613, Egypt
| | - Mahmoud A Eldin
- Chemistry Department, Faculty of Science, Cairo University, Giza, 12613, Egypt
| | - Ahmed Galal
- Chemistry Department, Faculty of Science, Cairo University, Giza, 12613, Egypt
| | - Nada F Atta
- Chemistry Department, Faculty of Science, Cairo University, Giza, 12613, Egypt.
| |
Collapse
|
4
|
Ahmed YM, Eldin MA, Galal A, Atta NF. Electrochemical sensor for simultaneous determination of antiviral favipiravir drug, paracetamol and vitamin C based on host-guest inclusion complex of β-CD/CNTs nanocomposite. Sci Rep 2023; 13:19910. [PMID: 37963918 PMCID: PMC10645768 DOI: 10.1038/s41598-023-45353-3] [Citation(s) in RCA: 2] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/03/2023] [Accepted: 10/18/2023] [Indexed: 11/16/2023] Open
Abstract
Favipiravir (FVI) is extensively used as an effective medication against several diverse infectious RNA viruses. It is widely administered as an anti-influenza drug. Combination therapy formed from FVI, paracetamol (PAR) and vitamin C (VC) is needed for treating patients diseased by RNA viruses. Thus, an efficient electrochemical sensor is developed for detecting FVI in human serum samples. The sensor is fabricated by casting a thin layer of carbon nanotubes (CNTs) over a glassy carbon (GC) electrode surface followed by electrodeposition of another layer of β-cyclodextrin (β-CD). Under optimized conditions, the sensor shows excellent catalytic effect for FVI, PAR and VC oxidation in the concentration ranges (0.08 µM → 80 µM), (0.08 µM → 50 µM) and (0.8 µM → 80 µM) with low detection limits of 0.011 μM, 0.042 μM and 0.21 μM, respectively. The combined effect of host-guest interaction ability of β-CD for the drugs, and a large conductive surface area of CNTs improves the sensing performance of the electrode. The sensor exhibits stable response over 4 weeks, good reproducibility, and insignificant interference from common species present in serum samples. The reliability of using the sensor in serum samples shows good recovery of FVI, PAR and VC.
Collapse
Affiliation(s)
- Yousef M Ahmed
- Chemistry Department, Faculty of Science, Cairo University, Giza, 12613, Egypt
| | - Mahmoud A Eldin
- Chemistry Department, Faculty of Science, Cairo University, Giza, 12613, Egypt
| | - Ahmed Galal
- Chemistry Department, Faculty of Science, Cairo University, Giza, 12613, Egypt
| | - Nada F Atta
- Chemistry Department, Faculty of Science, Cairo University, Giza, 12613, Egypt.
| |
Collapse
|
5
|
Imanzadeh H, Sefid-Sefidehkhan Y, Afshary H, Afruz A, Amiri M. Nanomaterial-based electrochemical sensors for detection of amino acids. J Pharm Biomed Anal 2023; 230:115390. [PMID: 37079932 DOI: 10.1016/j.jpba.2023.115390] [Citation(s) in RCA: 12] [Impact Index Per Article: 6.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/30/2022] [Revised: 03/24/2023] [Accepted: 04/08/2023] [Indexed: 04/22/2023]
Abstract
Amino acids are the building blocks of proteins and muscle tissue. They also play a significant role in physiological processes related to energy, recovery, mood, muscle and brain function, fat burning and stimulating growth hormone or insulin secretion. Accurate determination of amino acids in biological fluids is necessary because any changes in their normal ranges in the body warn diseases like kidney disease, liver disease, type 2 diabetes and cancer. To date, many methods such as liquid chromatography, fluorescence mass spectrometry, etc. have been used for the determination of amino acids. Compared with the above techniques, electrochemical systems using modified electrodes offer a rapid, accurate, cheap, real-time analytical path through simple operations with high selectivity and sensitivity. Nanomaterials have found many interests to create smart electrochemical sensors in different application fields e.g. biomedical, environmental, and food analysis because of their exceptional properties. This review summarizes recent advances in the development of nanomaterial-based electrochemical sensors in 2017-2022 for the detection of amino acids in various matrices such as serum, urine, blood and pharmaceuticals.
Collapse
Affiliation(s)
- Hamideh Imanzadeh
- Department of Chemistry, University of Mohaghegh Ardabili, Ardabil, Iran
| | | | - Hosein Afshary
- Department of Chemistry, University of Mohaghegh Ardabili, Ardabil, Iran
| | - Ali Afruz
- Department of Chemistry, University of Mohaghegh Ardabili, Ardabil, Iran
| | - Mandana Amiri
- Department of Chemistry, University of Mohaghegh Ardabili, Ardabil, Iran.
| |
Collapse
|
6
|
Parshina A, Yelnikova A, Kolganova T, Titova T, Yurova P, Stenina I, Bobreshova O, Yaroslavtsev A. Perfluorosulfonic Acid Membranes Modified with Polyaniline and Hydrothermally Treated for Potentiometric Sensor Arrays for the Analysis of Combination Drugs. MEMBRANES 2023; 13:311. [PMID: 36984697 PMCID: PMC10058550 DOI: 10.3390/membranes13030311] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 02/13/2023] [Revised: 03/03/2023] [Accepted: 03/06/2023] [Indexed: 06/18/2023]
Abstract
A novel potentiometric multisensory system for the analysis of sulfamethoxazole and trimethoprim combination drugs was developed. The potentiometric sensors (Donnan potential (DP) was used as an analytical signal) with an inner reference solution were based on perfluorosulfonic acid (PFSA) membranes modified with polyaniline (PANI) by in situ oxidative polymerization. The order of the membrane treatment with precursor solutions and their concentrations was varied. Additionally, the PFSA/PANI composite membranes were hydrothermally treated at 120 °C. The influence of the preparation conditions and the composition of membranes on their sorption and transport properties was studied. We estimated the factors affecting the sensitivity of DP-sensors based on the PFSA/PANI composite membranes to ions of sulfamethoxazole and trimethoprim simultaneously presented in solutions. A developed multisensory system provided a simultaneous determination of two analytes in aqueous solutions without preliminary separation, derivatization, or probe treatment. The re-estimation of the calibration characteristics of the multisensory system did not show a statistically significant difference after a year of its use. The limits of detection of sulfamethoxazole and trimethoprim were 1.4 × 10-6 and 8.5 × 10-8 M, while the relative errors of their determination in the combination drug were 4 and 5% (at 5 and 6% relative standard deviation), respectively.
Collapse
Affiliation(s)
- Anna Parshina
- Department of Analytical Chemistry, Voronezh State University, 394018 Voronezh, Russia
| | - Anastasia Yelnikova
- Department of Analytical Chemistry, Voronezh State University, 394018 Voronezh, Russia
| | - Tatyana Kolganova
- Department of Analytical Chemistry, Voronezh State University, 394018 Voronezh, Russia
| | - Tatyana Titova
- Kurnakov Institute of General and Inorganic Chemistry RAS, 119991 Moscow, Russia
| | - Polina Yurova
- Kurnakov Institute of General and Inorganic Chemistry RAS, 119991 Moscow, Russia
| | - Irina Stenina
- Kurnakov Institute of General and Inorganic Chemistry RAS, 119991 Moscow, Russia
| | - Olga Bobreshova
- Department of Analytical Chemistry, Voronezh State University, 394018 Voronezh, Russia
| | - Andrey Yaroslavtsev
- Kurnakov Institute of General and Inorganic Chemistry RAS, 119991 Moscow, Russia
| |
Collapse
|
7
|
Multisensory Systems Based on Perfluorosulfonic Acid Membranes Modified with Polyaniline and PEDOT for Multicomponent Analysis of Sulfacetamide Pharmaceuticals. Polymers (Basel) 2022; 14:polym14132545. [PMID: 35808592 PMCID: PMC9269069 DOI: 10.3390/polym14132545] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/31/2022] [Revised: 06/18/2022] [Accepted: 06/20/2022] [Indexed: 11/17/2022] Open
Abstract
The degradation of sulfacetamide with the formation of sulfanilamide leads to a deterioration in the quality of pharmaceuticals. In this work, potentiometric sensors for the simultaneous determination of sulfanilamide, sulfacetamide and inorganic ions, and for assessing the degradation of pharmaceuticals were developed. A multisensory approach was used for this purpose. The sensor cross-sensitivity to related analytes was achieved using perfluorosulfonic acid membranes with poly(3,4-ethylenedioxythiophene) or polyaniline as dopants. The composite membranes were prepared by oxidative polymerization and characterized using FTIR and UV-Vis spectroscopy, and SEM. The influence of the preparation procedure and the dopant concentration on the membrane hydrophilicity, ion-exchange capacity, water uptake, and transport properties was investigated. The characteristics of the potentiometric sensors in aqueous solutions containing sulfanilamide, sulfacetamide and alkali metals ions in a wide pH range were established. The introduction of proton-acceptor groups and π-conjugated moieties into the perfluorosulfonic acid membranes increased the sensor sensitivity to organic analytes. The relative errors of sulfacetamide and sulfanilamide determination in the UV-degraded eye drops were 1.2 to 1.4 and 1.7 to 4%, respectively, at relative standard deviation of 6 to 9%.
Collapse
|
8
|
Dinu A, Apetrei C. A Review of Sensors and Biosensors Modified with Conducting Polymers and Molecularly Imprinted Polymers Used in Electrochemical Detection of Amino Acids: Phenylalanine, Tyrosine, and Tryptophan. Int J Mol Sci 2022; 23:1218. [PMID: 35163145 PMCID: PMC8835779 DOI: 10.3390/ijms23031218] [Citation(s) in RCA: 24] [Impact Index Per Article: 8.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/13/2021] [Revised: 01/18/2022] [Accepted: 01/20/2022] [Indexed: 02/07/2023] Open
Abstract
Recently, the studies on developing sensors and biosensors-with an obvious interdisciplinary character-have drawn the attention of many researchers specializing in various fundamental, but also complex domains such as chemistry, biochemistry, physics, biophysics, biology, bio-pharma-medicine, and bioengineering. Along these lines, the present paper is structured into three parts, and is aimed at synthesizing the most relevant studies on the construction and functioning of versatile devices, of electrochemical sensors and biosensors, respectively. The first part presents examples of the most representative scientific research focusing on the role and the importance of the phenylalanine, tyrosine, and tryptophan amino acids, selected depending on their chemical structure and their impact on the central nervous system. The second part is dedicated to presenting and exemplifying conductor polymers and molecularly imprinted polymers used as sensitive materials in achieving electrochemical sensors and biosensors. The last part of the review analyzes the sensors and biosensors developed so far to detect amino acids with the aid of conductor polymers and molecularly imprinted polymers from the point of view of the performances obtained, with emphasis on the detection methods, on the electrochemical reactions that take place upon detection, and on the electroanalytical performances. The present study was carried out with a view to highlighting, for the benefit of specialists in medicine and pharmacy, the possibility of achieving and purchasing efficient devices that might be used in the quality control of medicines, as well as in studying and monitoring diseases associated with these amino acids.
Collapse
Affiliation(s)
| | - Constantin Apetrei
- Department of Chemistry, Physics and Environment, Faculty of Sciences and Environment, “Dunărea de Jos” University of Galati, RO-800008 Galati, Romania;
| |
Collapse
|
9
|
Dinu A, Apetrei C. Development of Polypyrrole Modified Screen-Printed Carbon Electrode Based Sensors for Determination of L-Tyrosine in Pharmaceutical Products. Int J Mol Sci 2021; 22:7528. [PMID: 34299146 PMCID: PMC8307433 DOI: 10.3390/ijms22147528] [Citation(s) in RCA: 11] [Impact Index Per Article: 2.8] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/15/2021] [Revised: 07/07/2021] [Accepted: 07/13/2021] [Indexed: 12/21/2022] Open
Abstract
Good health, of vital importance in order to carry out our daily routine, consists of both physical and mental health. Tyrosine (Tyr) deficiency as well as its excess are issues that can affect mental health and can generate disorders such as depression, anxiety, or stress. Tyr is the amino acid (AA) responsible for maintaining good mental health, and for this reason, the present research presents the development of new electrochemical sensors modified with polypyrrole (PPy) doped with different doping agents such as potassium hexacyanoferrate (II) (FeCN), sodium nitroprusside (NP), and sodium dodecyl sulfate (SDS) for a selective and sensitive detection of Tyr. The development of the sensors was carried out by chronoamperometry (CA) and the electrochemical characterization was carried out by cyclic voltammetry (CV). The detection limits (LOD) obtained with each modified sensor were 8.2 × 10-8 M in the case of PPy /FeCN-SPCE, 4.3 × 10-7 M in the case of PPy/NP-SPCE, and of 3.51 × 10-7 M in the case of PPy/SDS-SPCE, thus demonstrating a good sensitivity of these sensors detecting L-Tyr. The validation of sensors was carried out through quantification of L-Tyr from three pharmaceutical products by the standard addition method with recoveries in the range 99.92-103.97%. Thus, the sensors present adequate selectivity and can be used in the pharmaceutical and medical fields.
Collapse
Affiliation(s)
| | - Constantin Apetrei
- Faculty of Science and Environment, “Dunărea de Jos” University of Galati, 800008 Galati, Romania;
| |
Collapse
|
10
|
Atta NF, Abdo GG, Elzatahry A, Galal A, Hassan SH. Designed electrochemical sensor based on metallocene modified conducting polymer composite for effective determination of tramadol in real samples. CAN J CHEM 2021. [DOI: 10.1139/cjc-2020-0199] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/26/2022]
Abstract
A novel composite for the electrochemical sensing of tramadol (Tr) was developed by the inclusion of a metallocene mediator between two layers of conducting poly(3,4-ethylenedioxythiophene) (PEDOT) polymer, in the presence of sodium dodecyl sulfate (SDS), i.e., P/mediator/P⋯SDS. Three charge transfer mediators were evaluated: ferrocene carboxylic acid (FC1), ferrocene (FC2), and cobaltocene (CC) for Tr electrocatalytic oxidation. The FC1 charge mediator showed a relatively higher current response that was assisted by the electronic conduction of the polymer film. Moreover, SDS presented a great impact, resulting in the enhancement of the preconcentration and (or) accumulation of Tr ions at the interface, leading to faster electron transfer. In addition, the practical application of the proposed FC1 composite for the determination of Tr in real urine and serum samples was successfully achieved with adequate recovery results. Very low detection limits of 18.6 nM and 16 nM in the linear dynamic ranges of 7–300 µM and 5–280 µM, respectively, were obtained at the proposed sensor. Furthermore, the simultaneous determination of Tr with common interfering species, paracetamol (APAP), morphine (MO), dopamine (DA), ascorbic acid (AA) and uric acid (UA), proved excellent, with good resolution and large potential peaks separation. The excellent characteristics of the proposed composite such as high reproducibility, good sensitivity, selectivity, anti-interference ability, and good stability enhanced its application for determination of other narcotic drugs.
Collapse
Affiliation(s)
- Nada F. Atta
- Department of Chemistry, Faculty of Science, Cairo University, 12613, Giza, Egypt
| | - Ghada G. Abdo
- College of Pharmacy, Qatar University, P.O. Box, Doha 2713, Qatar
| | - Ahmed Elzatahry
- Materials Science and Technology Program, College of Arts and Sciences, Qatar University, Doha, 2713, Qatar
| | - Ahmed Galal
- Department of Chemistry, Faculty of Science, Cairo University, 12613, Giza, Egypt
| | - Samar H. Hassan
- Department of Chemistry, Faculty of Science, Cairo University, 12613, Giza, Egypt
| |
Collapse
|
11
|
An innovative design of hydrazine hydrate electrochemical sensor based on decoration of crown ether/Nafion/carbon nanotubes composite with gold nanoparticles. J Electroanal Chem (Lausanne) 2021. [DOI: 10.1016/j.jelechem.2021.115165] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/23/2022]
|
12
|
Atta NF, Galal A, Ahmed YM, Abdelkader MG. Development of an Innovative Nitrite Sensing Platform Based on the Construction of an Electrochemical Composite Sensor of Polymer Coated CNTs and Decorated with Magnetite Nanoparticles. ELECTROANAL 2021. [DOI: 10.1002/elan.202060598] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/15/2022]
Affiliation(s)
- Nada F. Atta
- Chemistry Department, Faculty of Science Cairo University 12613 Giza Egypt
| | - Ahmed Galal
- Chemistry Department, Faculty of Science Cairo University 12613 Giza Egypt
| | - Yousef M. Ahmed
- Chemistry Department, Faculty of Science Cairo University 12613 Giza Egypt
| | | |
Collapse
|
13
|
Stenina IA, Yurova PA, Titova TS, Polovkova MA, Korchagin OV, Bogdanovskaya VA, Yaroslavtsev AB. The influence of poly(3,4‐ethylenedioxythiophene) modification on the transport properties and fuel cell performance of Nafion‐117 membranes. J Appl Polym Sci 2021. [DOI: 10.1002/app.50644] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/12/2022]
Affiliation(s)
- Irina A. Stenina
- Kurnakov Institute of General and Inorganic Chemistry Russian Academy of Sciences Moscow Russia
- National Research University Higher School of Economics Basic Department of Inorganic Chemistry and Materials Science Moscow Russia
| | - Polina A. Yurova
- Kurnakov Institute of General and Inorganic Chemistry Russian Academy of Sciences Moscow Russia
- National Research University Higher School of Economics Basic Department of Inorganic Chemistry and Materials Science Moscow Russia
| | - Tatyana S. Titova
- Kurnakov Institute of General and Inorganic Chemistry Russian Academy of Sciences Moscow Russia
| | - Marina A. Polovkova
- Frumkin Institute of Physical Chemistry and Electrochemistry Russian Academy of Sciences Moscow Russia
| | - Oleg V. Korchagin
- Frumkin Institute of Physical Chemistry and Electrochemistry Russian Academy of Sciences Moscow Russia
| | - Vera A. Bogdanovskaya
- Frumkin Institute of Physical Chemistry and Electrochemistry Russian Academy of Sciences Moscow Russia
| | - Andrey B. Yaroslavtsev
- Kurnakov Institute of General and Inorganic Chemistry Russian Academy of Sciences Moscow Russia
- National Research University Higher School of Economics Basic Department of Inorganic Chemistry and Materials Science Moscow Russia
| |
Collapse
|
14
|
Atta NF, Galal A, Ahmed YM, Abdelkader MG. Host guest inclusion complex/polymer-CNT composite for efficient determination of uric acid in presence of interfering species. J Electroanal Chem (Lausanne) 2021. [DOI: 10.1016/j.jelechem.2021.115012] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/22/2022]
|
15
|
Khoshnevisan K, Baharifar H, Torabi F, Sadeghi Afjeh M, Maleki H, Honarvarfard E, Mohammadi H, Sajjadi-Jazi SM, Mahmoudi-Kohan S, Faridbod F, Larijani B, Saadat F, Faridi Majidi R, Khorramizadeh MR. Serotonin level as a potent diabetes biomarker based on electrochemical sensing: a new approach in a zebra fish model. Anal Bioanal Chem 2021; 413:1615-1627. [PMID: 33501550 DOI: 10.1007/s00216-020-03122-5] [Citation(s) in RCA: 8] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/06/2020] [Revised: 12/07/2020] [Accepted: 12/10/2020] [Indexed: 02/06/2023]
Abstract
Serotonin (5-HT) levels have been associated with several exclusively metabolic disorders. Herein, a new approach for 5-HT level as a novel biomarker of diabetes mellitus is considered using a simple nanocomposite and HPLC method. Reduced graphene oxide (rGO) comprising gold nanoparticles (AuNPs) was decorated with 18-crown-6 (18.Cr.6) to fabricate a simple nanocomposite (rGO-AuNPs-18.Cr.6). The nanocomposite was positioned on a glassy carbon electrode (GCE) to form an electrochemical sensor for the biomarker 5-HT in the presence of L-tryptophan (L-Trp), dopamine (DA), ascorbic acid (AA), urea, and glucose. The nanocomposite exhibited efficient catalytic activity for 5-HT detection by square-wave voltammetry (SWV). The proposed sensor displayed high selectivity, excellent reproducibility, notable anti-interference ability, and long-term stability even after 2 months. SWV defined a linear range of 5-HT concentration from 0.4 to 10 μg L-1. A diabetic animal model (diabetic zebrafish model) was then applied to investigate 5-HT as a novel biomarker of diabetes. A limit of detection (LOD) of about 0.33 μg L-1 was found for the diabetic group and 0.15 μg L-1 for the control group. The average levels of 5-HT obtained were 9 and 2 μg L-1 for control and diabetic groups, respectively. The recovery, relative standard deviation (RSD), and relative error (RE) were found to be about 97%, less than 2%, and around 3%, respectively. The significant reduction in 5-HT level in the diabetic group compared to the control group proved that the biomarker 5-HT can be applied for the early diagnosis of diabetes mellitus.
Collapse
Affiliation(s)
- Kamyar Khoshnevisan
- Biosensor Research Center, Endocrinology & Metabolism Molecular-Cellular Sciences Institute, Tehran University of Medical Sciences, Tehran, 1411713137, Iran. .,Endocrinology and Metabolism Research Center, Endocrinology and Metabolism Clinical Sciences Institute, Tehran University of Medical Sciences, Tehran, 1411713137, Iran. .,Zebrafish Core Facility, Endocrinology and Metabolism Research Institute, Tehran University of Medical Sciences, Tehran, 1411713137, Iran.
| | - Hadi Baharifar
- Department of Medical Nanotechnology, Applied Biophotonics Research Center, Science and Research Branch, Islamic Azad University, Tehran, 1477893855, Iran
| | - Farzad Torabi
- School of Chemistry, College of Science, University of Tehran, Tehran, 1417466191, Iran.,Center of Excellence in Electrochemistry, School of Chemistry, College of Science, University of Tehran, Tehran, 1417466191, Iran
| | - Mahsa Sadeghi Afjeh
- Endocrinology and Metabolism Research Center, Endocrinology and Metabolism Clinical Sciences Institute, Tehran University of Medical Sciences, Tehran, 1411713137, Iran
| | - Hassan Maleki
- Department of Medical Nanotechnology, School of Advanced Technologies in Medicine, Tehran University of Medical Sciences, Tehran, 1417755469, Iran
| | - Elham Honarvarfard
- Department of Chemistry and Biomolecular Science, Clarkson University, Potsdam, NY, 13699-5810, USA
| | - Hassan Mohammadi
- Zebrafish Core Facility, Endocrinology and Metabolism Research Institute, Tehran University of Medical Sciences, Tehran, 1411713137, Iran
| | - Sayed Mahmoud Sajjadi-Jazi
- Endocrinology and Metabolism Research Center, Endocrinology and Metabolism Clinical Sciences Institute, Tehran University of Medical Sciences, Tehran, 1411713137, Iran.,Cell Therapy and Regenerative Medicine Research Center, Endocrinology and Metabolism Molecular-Cellular Sciences Institute, Tehran University of Medical Sciences, Tehran, 1411713137, Iran
| | - Sadegh Mahmoudi-Kohan
- School of Chemistry, College of Science, University of Tehran, Tehran, 1417466191, Iran.,Center of Excellence in Electrochemistry, School of Chemistry, College of Science, University of Tehran, Tehran, 1417466191, Iran
| | - Farnoush Faridbod
- School of Chemistry, College of Science, University of Tehran, Tehran, 1417466191, Iran.,Center of Excellence in Electrochemistry, School of Chemistry, College of Science, University of Tehran, Tehran, 1417466191, Iran
| | - Bagher Larijani
- Endocrinology and Metabolism Research Center, Endocrinology and Metabolism Clinical Sciences Institute, Tehran University of Medical Sciences, Tehran, 1411713137, Iran
| | - Farshid Saadat
- Department of Immunology, School of Medicine, Guilan University of Medical Sciences, Rasht, 41887-94755, Iran
| | - Reza Faridi Majidi
- Department of Medical Nanotechnology, School of Advanced Technologies in Medicine, Tehran University of Medical Sciences, Tehran, 1417755469, Iran
| | - Mohammad Reza Khorramizadeh
- Biosensor Research Center, Endocrinology & Metabolism Molecular-Cellular Sciences Institute, Tehran University of Medical Sciences, Tehran, 1411713137, Iran. .,Endocrinology and Metabolism Research Center, Endocrinology and Metabolism Clinical Sciences Institute, Tehran University of Medical Sciences, Tehran, 1411713137, Iran. .,Zebrafish Core Facility, Endocrinology and Metabolism Research Institute, Tehran University of Medical Sciences, Tehran, 1411713137, Iran.
| |
Collapse
|
16
|
Atta NF, Abdel Gawad SA, Galal A, Razik AA, El-Gohary AR. Efficient electrochemical sensor for determination of H2O2 in human serum based on nano iron‑nickel alloy/carbon nanotubes/ionic liquid crystal composite. J Electroanal Chem (Lausanne) 2021. [DOI: 10.1016/j.jelechem.2020.114953] [Citation(s) in RCA: 13] [Impact Index Per Article: 3.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/21/2022]
|
17
|
Guo H, Fan T, Yao W, Yang W, Wu N, Liu H, Wang M, Yang W. Simultaneous determination of 4-aminophenol and acetaminophen based on high electrochemical performance of ZIF-67/MWCNT-COOH/Nafion composite. Microchem J 2020. [DOI: 10.1016/j.microc.2020.105262] [Citation(s) in RCA: 29] [Impact Index Per Article: 5.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/14/2022]
|
18
|
Zhang B, Jaouhari AE, Wu X, Liu W, Zhu J, Liu X. Synthesis and characterization of PEDOT-MC decorated AgNPs for voltammetric detection of rutin in real samples. J Electroanal Chem (Lausanne) 2020. [DOI: 10.1016/j.jelechem.2020.114632] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/29/2023]
|
19
|
Elugoke SE, Adekunle AS, Fayemi OE, Akpan ED, Mamba BB, Sherif EM, Ebenso EE. Molecularly imprinted polymers (MIPs) based electrochemical sensors for the determination of catecholamine neurotransmitters – Review. ELECTROCHEMICAL SCIENCE ADVANCES 2020. [DOI: 10.1002/elsa.202000026] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/22/2022] Open
Affiliation(s)
- Saheed E. Elugoke
- Material Science Innovation and Modelling (MaSIM) Research Focus Area, Faculty of Natural and Agricultural Sciences North‐West University (Mafikeng Campus) Mmabatho South Africa
- Department of Chemistry School of Physical and Chemical Sciences Faculty of Natural and Agricultural Sciences North‐West University (Mafikeng Campus) Mmabatho South Africa
| | - Abolanle S. Adekunle
- Material Science Innovation and Modelling (MaSIM) Research Focus Area, Faculty of Natural and Agricultural Sciences North‐West University (Mafikeng Campus) Mmabatho South Africa
- Department of Chemistry School of Physical and Chemical Sciences Faculty of Natural and Agricultural Sciences North‐West University (Mafikeng Campus) Mmabatho South Africa
- Department of Chemistry Obafemi Awolowo University Ile‐Ife Nigeria
| | - Omolola E. Fayemi
- Material Science Innovation and Modelling (MaSIM) Research Focus Area, Faculty of Natural and Agricultural Sciences North‐West University (Mafikeng Campus) Mmabatho South Africa
- Department of Chemistry School of Physical and Chemical Sciences Faculty of Natural and Agricultural Sciences North‐West University (Mafikeng Campus) Mmabatho South Africa
| | - Ekemini D. Akpan
- Material Science Innovation and Modelling (MaSIM) Research Focus Area, Faculty of Natural and Agricultural Sciences North‐West University (Mafikeng Campus) Mmabatho South Africa
| | - Bhekie B. Mamba
- Institute for Nanotechnology and Water Sustainability College of Science Engineering and Technology University of South Africa Johannesburg South Africa
| | - El‐Sayed M. Sherif
- Center of Excellence for Research in Engineering Materials (CEREM) King Saud University Al‐Riyadh Saudi Arabia
- Electrochemistry and Corrosion Laboratory Department of Physical Chemistry National Research Centre Dokki Cairo Egypt
| | - Eno E. Ebenso
- Material Science Innovation and Modelling (MaSIM) Research Focus Area, Faculty of Natural and Agricultural Sciences North‐West University (Mafikeng Campus) Mmabatho South Africa
- Institute for Nanotechnology and Water Sustainability College of Science Engineering and Technology University of South Africa Johannesburg South Africa
| |
Collapse
|
20
|
Elugoke SE, Adekunle AS, Fayemi OE, Mamba BB, Nkambule TT, Sherif EM, Ebenso EE. Progress in electrochemical detection of neurotransmitters using carbon nanotubes/nanocomposite based materials: A chronological review. NANO SELECT 2020. [DOI: 10.1002/nano.202000082] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/13/2022] Open
Affiliation(s)
- Saheed E. Elugoke
- Material Science Innovation and Modelling (MaSIM) Research Focus Area Faculty of Natural and Agricultural Sciences North‐West University (Mafikeng Campus) Mmabatho South Africa
- Department of Chemistry School of Physical and Chemical Sciences Faculty of Natural and Agricultural Sciences North‐West University (Mafikeng Campus) Mmabatho South Africa
| | - Abolanle S. Adekunle
- Material Science Innovation and Modelling (MaSIM) Research Focus Area Faculty of Natural and Agricultural Sciences North‐West University (Mafikeng Campus) Mmabatho South Africa
- Department of Chemistry School of Physical and Chemical Sciences Faculty of Natural and Agricultural Sciences North‐West University (Mafikeng Campus) Mmabatho South Africa
- Department of Chemistry Obafemi Awolowo University PMB Ile‐Ife Nigeria
| | - Omolola E. Fayemi
- Material Science Innovation and Modelling (MaSIM) Research Focus Area Faculty of Natural and Agricultural Sciences North‐West University (Mafikeng Campus) Mmabatho South Africa
- Department of Chemistry School of Physical and Chemical Sciences Faculty of Natural and Agricultural Sciences North‐West University (Mafikeng Campus) Mmabatho South Africa
| | - Bhekie B. Mamba
- Nanotechnology and Water Sustainability Research Unit College of Science Engineering and Technology University of South Africa Johannesburg South Africa
| | - Thabo T.I. Nkambule
- Nanotechnology and Water Sustainability Research Unit College of Science Engineering and Technology University of South Africa Johannesburg South Africa
| | - El‐Sayed M. Sherif
- Center of Excellence for Research in Engineering Materials (CEREM) King Saud University Al‐Riyadh Saudi Arabia
- Electrochemistry and Corrosion Laboratory Department of Physical Chemistry National Research Centre Dokki Cairo Egypt
| | - Eno E. Ebenso
- Material Science Innovation and Modelling (MaSIM) Research Focus Area Faculty of Natural and Agricultural Sciences North‐West University (Mafikeng Campus) Mmabatho South Africa
- Department of Chemistry School of Physical and Chemical Sciences Faculty of Natural and Agricultural Sciences North‐West University (Mafikeng Campus) Mmabatho South Africa
- Nanotechnology and Water Sustainability Research Unit College of Science Engineering and Technology University of South Africa Johannesburg South Africa
| |
Collapse
|
21
|
Safronova E, Parshina A, Kоlganova T, Yelnikova A, Bobreshova O, Pourcelly G, Yaroslavtsev A. Potentiometric multisensory system based on perfluorosulfonic acid membranes and carbon nanotubes for sulfacetamide determination in pharmaceuticals. J Electroanal Chem (Lausanne) 2020. [DOI: 10.1016/j.jelechem.2020.114435] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/23/2022]
|
22
|
Parshina AV, Safronova EY, Habtemariam GZ, Ryzhikh EI, Prikhno IA, Bobreshova OV, Yaroslavtsev AB. Potentiometric Sensors Based on MF-4SC Membranes and Carbon Nanotubes for the Determination of Nicotinic Acid in Aqueous Solutions and Pharmaceuticals. MEMBRANES AND MEMBRANE TECHNOLOGIES 2020. [DOI: 10.1134/s2517751620040083] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/23/2022]
|
23
|
Atta NF, Galal A, El-Gohary ARM. New insight for simultaneous determination of hazardous di-hydroxybenzene isomers at crown ether modified polymer/carbon nanotubes composite sensor. JOURNAL OF HAZARDOUS MATERIALS 2020; 388:122038. [PMID: 31968302 DOI: 10.1016/j.jhazmat.2020.122038] [Citation(s) in RCA: 22] [Impact Index Per Article: 4.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 09/27/2019] [Revised: 12/31/2019] [Accepted: 01/06/2020] [Indexed: 06/10/2023]
Abstract
A new insight is presented in the fabrication of a reliable electrochemical sensor for di-hydroxybenzene isomers; hydroquinone (HQ), catechol (CC), and resorcinol (RC) which have been considered as common pollutants in environment and water samples. The sensor is based on modifying the glassy carbon electrode (GC) with successive layers, multi-walled carbon nanotubes (CNT), poly-hydroquinone (PHQ) and benzo-12-crown-4 (CE); GC/CNT/PHQ/CE. CE is introduced for the first time as a receptor for the di-hydroxybenzene isomers based on host-guest size matching. Other cycling compound with different cavity diameter as β-cyclodextrin (β-CD) (6.0-6.5 Å) was examined displaying lower current responses. CE exhibited "fit" cavity size (1.20-1.50 Å). Thus, the inclusion complexes formed between β-CD and di-hydroxybenzene isomers are less stable. The layered sensor showed highly electro-catalytic activity for simultaneous determination of isomers; HQ, CC and RC in the concentration ranges of 0.03-100 μM, 0.01-100 μM and 0.05-100 μM with low detection limit values of 0.156 nM, 0.118 nM and 0.427 nM, respectively. The practical impact of the sensor was illustrated for determination of di-hydroxybenzene isomers in real water matrices from two different sources. Moreover, anti-interference ability of the layered sensor for determination of di-hydroxybenzene isomers was successfully achieved in presence of common interfering ions and organic pollutants.
Collapse
Affiliation(s)
- Nada F Atta
- Chemistry Department, Faculty of Science, Cairo University, 12613 Giza, Egypt.
| | - Ahmed Galal
- Chemistry Department, Faculty of Science, Cairo University, 12613 Giza, Egypt
| | - Asmaa R M El-Gohary
- Chemistry Department, Faculty of Science, Cairo University, 12613 Giza, Egypt
| |
Collapse
|
24
|
Determination of the biomarker L-tryptophan level in diabetic and normal human serum based on an electrochemical sensing method using reduced graphene oxide/gold nanoparticles/18-crown-6. Anal Bioanal Chem 2020; 412:3615-3627. [DOI: 10.1007/s00216-020-02598-5] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/01/2020] [Revised: 03/02/2020] [Accepted: 03/12/2020] [Indexed: 12/11/2022]
|
25
|
Chauhan N, Soni S, Agrawal P, Balhara YPS, Jain U. Recent advancement in nanosensors for neurotransmitters detection: Present and future perspective. Process Biochem 2020. [DOI: 10.1016/j.procbio.2019.12.016] [Citation(s) in RCA: 23] [Impact Index Per Article: 4.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 01/05/2023]
|
26
|
Atta NF, Galal A, El-Gohary AR. Crown ether modified poly(hydroquinone)/carbon nanotubes based electrochemical sensor for simultaneous determination of levodopa, uric acid, tyrosine and ascorbic acid in biological fluids. J Electroanal Chem (Lausanne) 2020. [DOI: 10.1016/j.jelechem.2020.114032] [Citation(s) in RCA: 27] [Impact Index Per Article: 5.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/21/2022]
|
27
|
Atta NF, Galal A, El-Said DM. Electrochemical sensor based on incorporation of gold nanoparticles, ionic liquid crystal, and β-cyclodextrin into carbon paste composite for ultra-sensitive determination of norepinephrine in real samples. CAN J CHEM 2019. [DOI: 10.1139/cjc-2019-0025] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/05/2023]
Abstract
A novel, reliable electrochemical sensor is fabricated for direct and sensitive determination of norepinephrine (NE) based on gold nanoparticles, ionic liquid crystal, and β-cyclodextrin modified carbon paste electrode, namely AuILCCDCPE. The ionic liquid crystal (ILC) played a key role in improving the current response of electro-oxidation of NE compared with other ionic liquids modified electrodes. The ILC increased the ionic conductivity of the paste and formed noncovalent interactions with both host (CD) and guest (NE) compounds. The solid state structure of the ILC helped in the formation of ordered films in the paste. Furthermore, CD and Au nanoparticles raised the stability and the electrocatalytic ability of the proposed sensor. Under optimized conditions, the fabricated electrochemical sensor showed a good electrochemical response towards NE in human urine in the linear dynamic ranges of 0.05–10 μmol/L and 20–300 μmol/L with a correlation coefficient of 0.999 and detection limit of 3.12 × 10−9 mol/L in the low concentration range. The practical analytical performance of the sensor was attained for determination of NE in real samples with satisfied recovery results. This sensor has great ability to be extended for electrochemical applications in assays of other drugs.
Collapse
Affiliation(s)
- Nada F. Atta
- Chemistry Department, Faculty of Science, Cairo University, Giza 12613, Egypt
- Chemistry Department, Faculty of Science, Cairo University, Giza 12613, Egypt
| | - Ahmed Galal
- Chemistry Department, Faculty of Science, Cairo University, Giza 12613, Egypt
- Chemistry Department, Faculty of Science, Cairo University, Giza 12613, Egypt
| | - Dalia M. El-Said
- Chemistry Department, Faculty of Science, Cairo University, Giza 12613, Egypt
- Chemistry Department, Faculty of Science, Cairo University, Giza 12613, Egypt
| |
Collapse
|
28
|
New strategy for determination of anti-viral drugs based on highly conductive layered composite of MnO2/graphene/ionic liquid crystal/carbon nanotubes. J Electroanal Chem (Lausanne) 2019. [DOI: 10.1016/j.jelechem.2019.02.056] [Citation(s) in RCA: 18] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/06/2023]
|