1
|
Dalla-Nora F, Da Rosa LS, Pereira GKR, Valandro LF, Rippe MP. Is dentin analogue material a viable substitute for human dentin in fatigue behavior studies? J Mech Behav Biomed Mater 2024; 150:106312. [PMID: 38134583 DOI: 10.1016/j.jmbbm.2023.106312] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/30/2023] [Revised: 12/04/2023] [Accepted: 12/07/2023] [Indexed: 12/24/2023]
Abstract
This study aimed to compare the fatigue performance of a lithium disilicate ceramic cemented on different substrates (human dentin and glass fiber-reinforced epoxy resin - GFRER), treated with different types of conditioning (CTR - without surface conditioning; HF5 - 5% hydrofluoric acid; HF10 - 10% hydrofluoric acid; H3PO4 - phosphoric acid 37%; SAND - sandblasting with aluminum oxide). The occlusal surface of human molars (DENT group) (n = 15) was ground for dentin exposure and the root portion was cut, then the dentin slice (2.0 mm thick) was conditioned with 37% phosphoric acid and a dual-curing dental adhesive was applied. The GFRER in a round-rod format was cut into discs (Ø = 10 mm, 2.0 mm thick). Lithium disilicate glass ceramic blocks (IPS e.max CAD, Ivoclar, Schaan, Liechtenstein) were shaped into a cylinder format and cut, resulting in 90 discs (Ø = 10 mm, 1.5 mm thick). The substrate materials of each group were etched according to the groups and the ceramic was etched with 5% hydrofluoric acid for 30 s. A silane coupling agent was applied over the cementation surface in ceramic and GFRER surfaces and a dual cement was used for cementation (ceramic/GFRER or dentin). The disc/disc sets were submitted to thermocycling (25,000 cycles + storage for 6 months), and then tested in step-wise accelerated cyclic fatigue test. The failure pattern and topography were analyzed and the roughness and contact angle were measured before and after surface treatment. The DENT group presented the lowest load to failure values and number of cycles to failure in fatigue (637.33 N; 118.333), showing no statistical similarity with any of the other tested groups (p < 0.05). The topographic analysis showed that all proposed surface treatments modified the substrate surface when compared to the CTR group. All of the fractographical inspections demonstrated failure by radial crack. Considering the roughness analysis, the post-etched DENT group showed similar roughness to all groups of GFRER materials with their surface treated, except for SAND, which showed greater roughness and statistically different from the other groups. The DENT group (49.5) showed statistically different post-conditioning contact angle values from the HF10 group (96.5) and similar to the other groups. The glass fiber-reinforced epoxy resin was not able to simulate the results presented by the human dentin substrate when cemented to lithium disilicate regarding fatigue failure load and number of cycles for failure, regardless of the surface treatment. Lithium disilicate cemented on dentin analogue overestimates the load values for fatigue failure.
Collapse
Affiliation(s)
- F Dalla-Nora
- MSciD and PhD Post-Graduate Program in Oral Science [Prosthodontics Units], Faculty of Dentistry, Federal University of Santa Maria [UFSM], Avenue Roraima 1000, Building 26F, room 2383, Zip Code: 97105-900, Santa Maria, Rio Grande do Sul State, Brazil.
| | - L S Da Rosa
- MSciD and PhD Post-Graduate Program in Oral Science [Prosthodontics Units], Faculty of Dentistry, Federal University of Santa Maria [UFSM], Avenue Roraima 1000, Building 26F, room 2383, Zip Code: 97105-900, Santa Maria, Rio Grande do Sul State, Brazil.
| | - G K R Pereira
- MSciD and PhD Post-Graduate Program in Oral Science [Prosthodontics Units], Faculty of Dentistry, Federal University of Santa Maria [UFSM], Avenue Roraima 1000, Building 26F, room 2383, Zip Code: 97105-900, Santa Maria, Rio Grande do Sul State, Brazil.
| | - L F Valandro
- MSciD and PhD Post-Graduate Program in Oral Science [Prosthodontics Units], Faculty of Dentistry, Federal University of Santa Maria [UFSM], Avenue Roraima 1000, Building 26F, room 2383, Zip Code: 97105-900, Santa Maria, Rio Grande do Sul State, Brazil.
| | - M P Rippe
- MSciD and PhD Post-Graduate Program in Oral Science [Prosthodontics Units], Faculty of Dentistry, Federal University of Santa Maria [UFSM], Avenue Roraima 1000, Building 26F, room 2383, Zip Code: 97105-900, Santa Maria, Rio Grande do Sul State, Brazil.
| |
Collapse
|
2
|
Tribst JPM, Etoeharnowo L, Tadros M, Feilzer AJ, Werner A, Kleverlaan CJ, Dal Piva AMDO. The influence of pre-heating the restoration and luting agent on the flexural strength of indirect ceramic and composite restorations. Biomater Investig Dent 2023; 10:2279066. [PMID: 38979098 PMCID: PMC11229669 DOI: 10.1080/26415275.2023.2279066] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/28/2023] [Accepted: 10/30/2023] [Indexed: 07/10/2024] Open
Abstract
Background This study investigated the impact of luting procedure and restoration thicknesses on the flexural strength of CAD/CAM restorations. Traditional luting agents have been questioned in favor of pre-heated resin composites or flowable composites. Materials and Methods 400 disc-shaped restorations (lithium disilicate [IPS e.max CAD] or resin composite [Tetric CAD, Ivoclar]) were cemented onto dentin analog discs using different procedures (n = 20): dual-curing resin cement (Panavia V5), light-curing resin cement (Panavia Veneer LC), pre-heated resin composite (Clearfil™ AP-X) with or without pre-heated restoration, and high-filled flowable composite (Clearfil Majesty™ Flow). The biaxial flexural strength was calculated. Results There were significant effects of material, thickness, and luting procedure on flexural strength (p < 0.001). Resin composite specimens exhibited lower flexural strength (90 MPa) compared to lithium disilicate specimens (571 MPa), with thicker restorations (338 MPa) being stronger than thinner ones (323 MPa). Light-curing cement showed the highest strength (408.8 MPa)A, followed by dual-curing cement (362 MPa)B, pre-heated cement with pre-heated composite (318 MPa)C, pre-heated composite (304 MPa)C, and flowable resin composite (259 MPa)D. The light-curing cement yielded similar results to the pre-heated resin composite associated or not with the pre-heated crown for the thicker lithium disilicate specimens, whereas for the thinner lithium disilicate specimens all luting procedures performed similarly. Thin resin composite discs showed higher flexural strength when luted with light-curing cement, whereas the luting procedure had less influence for the thicker restorations. Conclusion Luting procedures impact the flexural strength of CAD/CAM lithium disilicate and resin composite restorations. Pre-heated resin composite, with or without pre-heated restoration, can replace dual-curing cement. Nevertheless, light-curing cement is superior for resin composite and 1.5 mm lithium disilicate restorations.
Collapse
Affiliation(s)
- João Paulo Mendes Tribst
- Department of Reconstructive Oral Care, Academic Centre for Dentistry Amsterdam (ACTA), Universiteit van Amsterdam and Vrije Universiteit, Amsterdam, North Holland, the Netherlands
| | - Lilis Etoeharnowo
- Department of Dental Materials Science, Academic Centre for Dentistry Amsterdam (ACTA), Universiteit van Amsterdam and Vrije Universiteit, Amsterdam, North Holland, the Netherlands
| | - Maril Tadros
- Department of Dental Materials Science, Academic Centre for Dentistry Amsterdam (ACTA), Universiteit van Amsterdam and Vrije Universiteit, Amsterdam, North Holland, the Netherlands
| | - Albert J Feilzer
- Department of Reconstructive Oral Care, Academic Centre for Dentistry Amsterdam (ACTA), Universiteit van Amsterdam and Vrije Universiteit, Amsterdam, North Holland, the Netherlands
- Department of Dental Materials Science, Academic Centre for Dentistry Amsterdam (ACTA), Universiteit van Amsterdam and Vrije Universiteit, Amsterdam, North Holland, the Netherlands
| | - Arie Werner
- Department of Reconstructive Oral Care, Academic Centre for Dentistry Amsterdam (ACTA), Universiteit van Amsterdam and Vrije Universiteit, Amsterdam, North Holland, the Netherlands
| | - Cornelis J Kleverlaan
- Department of Dental Materials Science, Academic Centre for Dentistry Amsterdam (ACTA), Universiteit van Amsterdam and Vrije Universiteit, Amsterdam, North Holland, the Netherlands
| | - Amanda Maria de Oliveira Dal Piva
- Department of Dental Materials Science, Academic Centre for Dentistry Amsterdam (ACTA), Universiteit van Amsterdam and Vrije Universiteit, Amsterdam, North Holland, the Netherlands
| |
Collapse
|
3
|
A brief review on fatigue test of ceramic and some related matters in Dentistry. J Mech Behav Biomed Mater 2023; 138:105607. [PMID: 36549251 DOI: 10.1016/j.jmbbm.2022.105607] [Citation(s) in RCA: 12] [Impact Index Per Article: 6.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/22/2022] [Revised: 11/28/2022] [Accepted: 12/05/2022] [Indexed: 12/12/2022]
Abstract
The characteristics of dental ceramics have been extensively studied over the years to provide highly qualified materials for use in prosthetic restorations. The ability to adhere to dental substrates, outstanding aesthetics (translucency, color, and substrate masking ability) and improved mechanical properties provide these materials with optical features and high strength to withstand masticatory stimuli. Different classifications are adopted, and it is generally considered that glass-ceramics have better optical characteristics due to the high glass content, and polycrystalline ceramics have superior strength favored by their densified and organized crystals, hampering crack growth. This knowledge was largely built-up during years of scientific research through different testing methodologies, but mainly employing static loads. It is important to not only take into account the intensity of loads that these materials will be exposed to, but also the effect of the intermittence of cyclic load application leading to mechanical fatigue and the influence of factors related to the crack origin and their propagation under this condition. Furthermore, the bonding surface of ceramic restorations requires surface treatments that improve the bond strength to luting agents; however, these treatments require caution because of their potential to produce defects and affect the structural behavior. Moreover, ceramic restorations often require internal adjustments for proper seating or external adjustments for fitting the occlusal contact with the antagonist. In this sense, finishing/polishing protocols may alter the defect population, as luting agents may also interact by filling in the superficial defects on the restoration intaglio surface. Thus, the balance among all these factors will define the performance of a restorative setup, as well as the posterior exposure to the humid environment and the masticatory stimuli (cyclical loading), which may favor developing slow and subcritical growth of cracks in ceramic materials and the degradation of the bond interface. Therefore, it is essential that the concepts which explain the fatigue mechanism are understood, as well as the crack propagation and failure patterns of restorative ceramic materials.
Collapse
|
4
|
Guilardi LF, Pereira G, Giordani JC, Kleverlaan CJ, Valandro LF, Rippe MP. Cement Choice and the Fatigue Performance of Monolithic Zirconia Restorations. Oper Dent 2022; 47:461-472. [PMID: 35917240 DOI: 10.2341/20-143-l] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Accepted: 10/21/2021] [Indexed: 11/23/2022]
Abstract
This study investigated the fatigue failure load of simplified monolithic yttria partially stabilized zirconia polycrystal restorations cemented to a dentin-like substrate using different luting systems. Disc-shaped ceramic (Zenostar T, 10 mm Ø × 0.7 mm thick) and dentin-like substrate (10 mm Ø × 2.8 mm thick) were produced and randomly allocated into eight groups, without or with thermocycling (TC=5-55°C/12,000×): "cement" (RelyX Luting 2 - glass ionomer cement [Ion], [Ion/TC]; RelyX U200 - self-adhesive resin cement [Self], [Self/TC]; Single Bond Universal+RelyX Ultimate - MDP-containing adhesive + resin cement [MDPAD + RC], [MDP-AD + RC/TC]; ED Primer II+Panavia F 2.0 - Primer + MDP-containing resin cement [PR + MDP-RC], [PR + MDP-RC/TC])). Each luting system was used as recommended by the manufacturer. Staircase methodology (20 Hz; 250,000 cycles) was applied for obtaining the fatigue failure loads. Fractographic characteristics were also assessed. At baseline, the Ion group presented the lowest fatigue load, although it was statistically similar to the Self group. The resin-based cement systems presented the highest fatigue performance, with the Ion group being only statistically equal to the Self group. Thermocycling influenced the groups differently. After aging, the MDP-AD + RC presented the highest mean, followed by the PR + MDP-RC and Self groups, while the Ion group had the lowest mean. Fractographic analysis depicted all failures as radial cracks starting at the zirconia intaglio surface. The luting system with MDP-containing adhesive applied prior to the resin cement presented the highest fatigue failure load after aging, presenting the best predictability of stable performance. Despite this, monolithic zirconia presents high load-bearing capability regardless of the luting agent.
Collapse
Affiliation(s)
- L F Guilardi
- Luis Felipe Guilardi, associate researcher, Post-Graduate Program in Oral Science (Prosthodontics Unit), Faculty of Dentistry, Federal University of Santa Maria (UFSM), Santa Maria, Rio Grande do Sul State, Brazil
| | - Gkr Pereira
- Gabriel Kalil Rocha Pereira, MsciD, PhD, adjunct professor, Post-Graduate Program in Oral Science (Prosthodontics Units), Faculty of Dentistry, Federal University of Santa Maria (UFSM), Santa Maria, Rio Grande do Sul State, Brazil
| | - J C Giordani
- João Carlos Giordani, undergraduate student, Faculty of Dentistry, Federal University of Santa Maria (UFSM), Santa Maria, Rio Grande do Sul State, Brazil
| | - C J Kleverlaan
- Cornelis Johannes Kleverlaan, PhD, full professor, Department of Dental Materials Science, Academic Centre for Dentistry Amsterdam, Universiteit van Amsterdam and Vrije Universiteit, Amsterdam, Noord-Holland, The Netherlands
| | - L F Valandro
- Luiz Felipe Valandro, MSciD, PhD, full professor, Post-Graduate Program in Oral Science (Prosthodontics Units), Faculty of Dentistry, Federal University of Santa Maria (UFSM), Santa Maria, Rio Grande do Sul State, Brazil
| | - M P Rippe
- *Marilia Pivetta Rippe, MSciD, PhD, adjunct professor, Post-Graduate Program in Oral Science (Prosthodontics Units), Faculty of Dentistry, Federal University of Santa Maria (UFSM), Santa Maria, Rio Grande do Sul State, Brazil
| |
Collapse
|
5
|
Prott LS, Spitznagel FA, Bonfante EA, Malassa MA, Gierthmuehlen PC. Monolithic zirconia crowns: effect of thickness reduction on fatigue behavior and failure load. J Adv Prosthodont 2021; 13:269-280. [PMID: 34777717 PMCID: PMC8558575 DOI: 10.4047/jap.2021.13.5.269] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/26/2021] [Revised: 08/30/2021] [Accepted: 09/14/2021] [Indexed: 11/23/2022] Open
Abstract
PURPOSE The objective of this study was to evaluate the effect of thickness reduction and fatigue on the failure load of monolithic zirconia crowns. MATERIALS AND METHODS 140 CAD-CAM fabricated crowns (3Y-TZP, inCorisTZI, Dentsply-Sirona) with different ceramic thicknesses (2.0, 1.5, 1.0, 0.8, 0.5 mm, respectively, named G2, G1.5, G1, G0.8, and G0.5) were investigated. Dies of a mandibular first molar were made of composite resin. The zirconia crowns were luted with a resin composite cement (RelyX Unicem 2 Automix, 3M ESPE). Half of the specimens (n = 14 per group) were mouth-motion-fatigued (1.2 million cycles, 1.6 Hz, 200 N/ 5 – 55℃, groups named G2-F, G1.5-F, G1-F, G0.8-F, and G0.5-F). Single-load to failure was performed using a universal testing-machine. Fracture modes were analyzed. Data were statistically analyzed using a Weibull 2-parameter distribution (90% CI) to determine the characteristic strength and Weibull modulus differences among the groups. RESULTS Three crowns (21%) of G0.8 and five crowns (36%) of G0.5 showed cracks after fatigue. Characteristic strength was the highest for G2, followed by G1.5. Intermediate values were observed for G1 and G1-F, followed by significantly lower values for G0.8, G0.8-F, and G0.5, and the lowest for G0.5-F. Weibull modulus was the lowest for G0.8, intermediate for G0.8-F and G0.5, and significantly higher for the remaining groups. Fatigue only affected G0.5-F. CONCLUSION Reduced crown thickness lead to reduced characteristic strength, even under failure loads that exceed physiological chewing forces. Fatigue significantly reduced the failure load of 0.5 mm monolithic 3Y-TZP crowns.
Collapse
Affiliation(s)
- Lea Sophia Prott
- Department of Prosthodontics, Medical Faculty and University Hospital Düsseldorf, Heinrich-Heine-University, Düsseldorf, Germany
| | - Frank Akito Spitznagel
- Department of Prosthodontics, Medical Faculty and University Hospital Düsseldorf, Heinrich-Heine-University, Düsseldorf, Germany
| | - Estevam Augusto Bonfante
- Department of Prosthodontics and Periodontology, Bauru School of Dentistry, University of Sao Paulo, Bauru, SP, Brazil
| | | | - Petra Christine Gierthmuehlen
- Department of Prosthodontics, Medical Faculty and University Hospital Düsseldorf, Heinrich-Heine-University, Düsseldorf, Germany
| |
Collapse
|
6
|
Bastos-Bitencourt NA, Soares Bombonatti JF, Bitencourt SB, Hatton BD, De Souza GM. Mechanical performance of a hybrid zirconia developed through hydrothermal treatment and Room-Temperature Atomic Layer Deposition (RT-ALD). J Mech Behav Biomed Mater 2021; 123:104783. [PMID: 34419886 DOI: 10.1016/j.jmbbm.2021.104783] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/11/2021] [Revised: 08/10/2021] [Accepted: 08/16/2021] [Indexed: 10/20/2022]
Abstract
OBJECTIVE A silica-based nanofilm has been successfully deposited via Room-Temperature Atomic Layer Deposition (RT-ALD) on the surface of a glass. The purpose of this study was to evaluate the mechanical performance of a hybrid interface created between yttria-stabilized zirconia (Y-PSZ) transformed layer and silica-based nanofilm via RT-ALD. MATERIAL AND METHODS Fully-sintered Y-PSZ (14 × 4.0 × 1.5 mm) specimens in different translucencies (MO, MT, LT; IPS e.max Zircad, Ivoclar Vivadent) were distributed in 5 groups: control (C - no treatment); hydrothermal treatment (HT- 15h, 134°C, 2 bar); alumina blasting (B - 50 μm Al2O3); RT-ALD silica deposition (S); HT followed by silica deposition (HTS). RT-ALD cycles consisted of the sequential exposure of specimens to tetramethoxysilane orthosilicate (TMOS - 60s) and ammonium hydroxide (NH4OH - 10 min) vapors in 40 cycles. Mechanical performance was analyzed by flexural strength (FS) (n = 10) and fatigue failure load (staircase method; n = 20) tests. Surface hardness (H) and Young's modulus (YM) were analyzed by nanoindentation. For surface chemical and topographical characterization, X-ray photoelectron spectroscopy (XPS) and scanning electron microscopy (SEM) were performed. Data from surface H, YM, FS, and fatigue limit (FL) were analyzed by two-way analysis of variance (ANOVA). RESULTS The interaction between material and treatment had a significant effect on FS (p < 0.001). The FS values ranged from 436.23 MPa to 856.65 MPa. HT resulted in the highest FS (856.65 MPa) for LT and the lowest FS (436.23 MPa) for MO zirconia. For all materials, S and B treatments resulted in similar FS values (p > 0.410). S did not affect FL when compared to the C group (p > 0.277) for any material investigated. HTS resulted in higher FL than S for LT and MO materials (p < 0.001). Surface hardness and modulus were similar between control and S-treated specimens for all materials analyzed. XPS analysis showed homogeneous silica content after 20 and 40 RT-ALD cycles, and SEM did not show significant changes in surface morphology between C and S-treated specimens. CONCLUSION RT-ALD resulted in effective silica deposition without any deleterious effect on zirconia-based materials mechanical properties. Alumina blasting promoted higher alteration on surface topography. HT prior to S resulted in superior FL (for MO and MT) and flexural strength (MO) for some of the materials investigated.
Collapse
Affiliation(s)
- Natália Almeida Bastos-Bitencourt
- Department of Operative Dentistry, Endodontics and Dental Materials, Bauru School of Dentistry, University of Sao Paulo, Bauru, Brazil
| | - Juliana Fraga Soares Bombonatti
- Department of Operative Dentistry, Endodontics and Dental Materials, Bauru School of Dentistry, University of Sao Paulo, Bauru, Brazil
| | - Sandro Basso Bitencourt
- Department of Dental Materials and Prosthodontics, Sao Paulo State University (UNESP), School of Dentistry, Araçatuba, Sao Paulo, Brazil
| | - Benjamin D Hatton
- Materials Science and Engineering, University of Toronto, ON, Canada
| | | |
Collapse
|
7
|
Yu Y, Cui M, Lin T, Liu C, Jin X, Chen H, Zheng R, Huang S, Ma J. Effect of zirconia surface modification using dopamine polymerisation on the shear bond strength of resin cement. Eur J Oral Sci 2021; 129:e12797. [PMID: 34009679 DOI: 10.1111/eos.12797] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/28/2021] [Revised: 03/30/2021] [Accepted: 04/12/2021] [Indexed: 11/27/2022]
Abstract
This study evaluated the influence of polydopamine treatment on the surface properties and bond strength of yttria-stabilised tetragonal zirconia polycrystal (Y-TZP). Sixty-three zirconia blocks (10 × 10 × 2 mm) were randomly divided into three groups defined by surface treatment: (i) control group (C), (ii) grit-blasted with 110 μm alumina particles (GB), and (iii) polydopamine (PDA) coating. The surfaces of specimens subjected to different treatments were investigated by X-ray photoelectron spectroscopy (XPS), scanning electron microscopy (SEM), and water contact angle measurements. After the surface treatments, the specimens were cemented to resin composite cylinders. After bonding, the shear bond strength of the ceramic to the resin was measured, and the failure mode of each specimen was analysed using a stereomicroscope. The results indicated that the shear bond strength is highest for the GB treatment and lowest for the controls. However, the difference between groups GB and PDA was not statistically significant. In the control group, adhesive failure was predominant, whereas in the treatment groups, mixed mode failure was predominant. The pre-treatment of Y-TZP ceramic with the polydopamine coating might improve the bond strength of the resin cement to the zirconia ceramic.
Collapse
Affiliation(s)
- Yi Yu
- School and Hospital of Stomatology, Wenzhou Medical University, Wenzhou, China.,Institute of Stomatology, School and Hospital of Stomatology, Wenzhou Medical University, Wenzhou, China
| | - Maiyin Cui
- Institute of Neuroscience, School of Basic Medical Sciences, Wenzhou Medical University, Wenzhou, China.,Department of Histology and Embryology, School of Basic Medical Sciences, Wenzhou Medical University, Wenzhou, China
| | - Tingting Lin
- School and Hospital of Stomatology, Wenzhou Medical University, Wenzhou, China.,Institute of Stomatology, School and Hospital of Stomatology, Wenzhou Medical University, Wenzhou, China
| | - Chuantong Liu
- School and Hospital of Stomatology, Wenzhou Medical University, Wenzhou, China.,Institute of Stomatology, School and Hospital of Stomatology, Wenzhou Medical University, Wenzhou, China
| | - Xiaoting Jin
- School and Hospital of Stomatology, Wenzhou Medical University, Wenzhou, China.,Institute of Stomatology, School and Hospital of Stomatology, Wenzhou Medical University, Wenzhou, China
| | - Huanhuan Chen
- Institute of Stomatology, School and Hospital of Stomatology, Wenzhou Medical University, Wenzhou, China
| | - Ruibin Zheng
- School and Hospital of Stomatology, Wenzhou Medical University, Wenzhou, China.,Institute of Stomatology, School and Hospital of Stomatology, Wenzhou Medical University, Wenzhou, China
| | - Shengbin Huang
- School and Hospital of Stomatology, Wenzhou Medical University, Wenzhou, China.,Institute of Stomatology, School and Hospital of Stomatology, Wenzhou Medical University, Wenzhou, China
| | - Jianfeng Ma
- School and Hospital of Stomatology, Wenzhou Medical University, Wenzhou, China.,Institute of Stomatology, School and Hospital of Stomatology, Wenzhou Medical University, Wenzhou, China
| |
Collapse
|
8
|
Diniz V, Condé Oliveira Prado PH, Meireles Rodrigues JV, Monteiro JB, Zucuni C, Valandro LF, Melo RM. Ceramic firing protocols and thermocycling: effects on the load-bearing capacity under fatigue of a bonded zirconia lithium silicate glass-ceramic. J Mech Behav Biomed Mater 2020; 110:103963. [DOI: 10.1016/j.jmbbm.2020.103963] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/26/2020] [Revised: 06/24/2020] [Accepted: 06/28/2020] [Indexed: 12/19/2022]
|
9
|
Cadore-Rodrigues AC, Machado PS, Oliveira JSD, Jahn SL, Callegari GL, Dorneles LS, Burgo TADL, Rippe MP, Rocha Pereira GK, Valandro LF. Fatigue performance of fully-stabilized zirconia polycrystals monolithic restorations: The effects of surface treatments at the bonding surface. J Mech Behav Biomed Mater 2020; 110:103962. [PMID: 32957253 DOI: 10.1016/j.jmbbm.2020.103962] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/13/2020] [Revised: 06/24/2020] [Accepted: 06/28/2020] [Indexed: 10/23/2022]
Abstract
This study evaluated the distinct conditioning effect of the intaglio surface of bonded fully-stabilized zirconia (FSZ) simplified restorations on the mechanical fatigue behavior of the set prior to and after aging. Ceramic disc shaped specimens (Ø= 10 mm and 1 mm thick) were randomly allocated into 14 groups considering: "surface treatments" (Ctrl: no-treatment; PM: universal primer; GLZ: low-fusing porcelain glaze; SNF: 5 nm SiO2 nanofilm deposition; AlOx: air-abrasion with aluminum oxide; SiC: air-abrasion with silica-coated aluminum oxide; 7%Si: air-abrasion with 7% silica-coated aluminum oxide); and "aging" (baseline: 24 h at 37 °C in water; or aged: 90 days at 37 °C in water + 12,000 thermal cycles). The discs were treated, luted with resin cement onto the dentin analog, subjected to aging or not, and then tested under a step-stress fatigue test at 20 Hz, 10,000 cycles/step, step-size of 100N starting at 200N, and proceeding until failure detection. Fractographic, topographic, surface roughness, contact angle, and atomic force microscopy analyzes were performed. The surface treatments at baseline led to statistically similar fatigue failure loads (953N-1313N), except for GLZ (1313N), which was significantly higher than 7%Si (953 N). Meanwhile, Ctrl had 40% pre-test failures (debonding) after aging, and therefore the worst fatigue performance (notable decrease in fatigue results), while all the other groups presented superior and statistically similar fatigue behavior (973-1271N). In fact, when considering baseline Vs aging conditions, stable fatigue results could only be noted when using surface treatments. In conclusion, internal surface treatments of FSZ ceramic restorations are mandatory for fatigue behavior stability after aging the restorative set, while non-treatment induced unstable results.
Collapse
Affiliation(s)
| | - Pablo Soares Machado
- Oral Science, Federal University of Santa Maria, Santa Maria, Rio Grande do Sul State, Brazil.
| | | | - Sérgio Luiz Jahn
- Chemical Engineering, Federal University of Santa Maria, Santa Maria, Rio Grande do Sul State, Brazil.
| | | | | | | | - Marilia Pivetta Rippe
- Post-Graduate Program in Oral Science, Prosthodontic Unit, Federal University of Santa Maria, Santa Maria, Rio Grande do Sul State, Brazil.
| | | | - Luiz Felipe Valandro
- Oral Science, Federal University of Santa Maria, Santa Maria, Rio Grande do Sul State, Brazil.
| |
Collapse
|
10
|
High load frequency at 20Hz: Its effects on the fatigue behavior of a leucite-reinforced glass-ceramic. J Mech Behav Biomed Mater 2020; 107:103769. [DOI: 10.1016/j.jmbbm.2020.103769] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/20/2020] [Revised: 03/30/2020] [Accepted: 03/31/2020] [Indexed: 12/27/2022]
|
11
|
Türkaslan S, Mutluay MM, Vallittu PK, Arola D, Tezvergil-Mutluay A. Fatigue resistance of metal-free cantilever bridges supported by labial laminate veneers. J Mech Behav Biomed Mater 2020; 103:103596. [PMID: 32090925 DOI: 10.1016/j.jmbbm.2019.103596] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/23/2019] [Revised: 11/18/2019] [Accepted: 12/10/2019] [Indexed: 11/28/2022]
Affiliation(s)
- Süha Türkaslan
- Suleyman Demirel University, Faculty of Dentistry, Department of Prosthodontics, Isparta, Turkey
| | - Mustafa Murat Mutluay
- Adhesive Dentistry Research Group, Department of Restorative Dentistry and Cardiology, Institute of Dentistry, University of Turku, Turku, Finland; Institute of Dentistry, University of Eastern Finland, Kuopio, Finland; Kuopio University Hospital, Kuopio, Finland.
| | - Pekka K Vallittu
- Department of Biomaterials Science, Turku University, and City of Turku, Welfare Division, Turku, Finland
| | - Dwayne Arola
- Materials Science and Engineering, University of Washington, Seattle, WA, USA; Department of Restorative Dentistry and Department of Oral Health Sciences, Dental School, University of Washington Seattle, WA, USA
| | - Arzu Tezvergil-Mutluay
- Adhesive Dentistry Research Group, Department of Restorative Dentistry and Cardiology, Institute of Dentistry, University of Turku, Turku, Finland; Turku University Hospital, TYKS, Turku, Finland
| |
Collapse
|
12
|
Nanostructured Zirconia-Based Ceramics and Composites in Dentistry: A State-of-the-Art Review. NANOMATERIALS 2019; 9:nano9101393. [PMID: 31569589 PMCID: PMC6836160 DOI: 10.3390/nano9101393] [Citation(s) in RCA: 25] [Impact Index Per Article: 4.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 08/31/2019] [Revised: 09/18/2019] [Accepted: 09/25/2019] [Indexed: 12/12/2022]
Abstract
The objective of this paper is to review the current knowledge on the development of nanostructured zirconia-based ceramics and composites suitable for application in dentistry. Isi Web of Science, Science Direct, Scientific.net databases, and Google were searched electronically for the period of 1980 to the present, matching the keywords “nano” with the keywords: “Zirconia, ZrO2, Y-TZP, and dental, dentistry”. A total of 74 papers were found, with the majority coming from Asia, indicating a more active scientific interest on the topic in this geographic area, followed by Europe, South America, and North America. The research shows, even though the scientific activity on nanostructured ceramics was intense in the last fifteen years, the development of fully dense zirconia-based nanoceramics is yet at an initial stage, most of all from the point of view of the clinical applications. It has been demonstrated that nanostructured ceramics can show improved properties because of the reduction of the grain size to the nanoscale. This is also true for zirconia-based nanoceramics, where some improvements in mechanical, optical, as well as resistance in low-temperature degradation have been observed. Potential applications of this class of material in the dental field are discussed, summarizing the results of the latest scientific research.
Collapse
|