1
|
Trautmann EM, Hesse JK, Stine GM, Xia R, Zhu S, O'Shea DJ, Karsh B, Colonell J, Lanfranchi FF, Vyas S, Zimnik A, Steinmann NA, Wagenaar DA, Andrei A, Lopez CM, O'Callaghan J, Putzeys J, Raducanu BC, Welkenhuysen M, Churchland M, Moore T, Shadlen M, Shenoy K, Tsao D, Dutta B, Harris T. Large-scale high-density brain-wide neural recording in nonhuman primates. BIORXIV : THE PREPRINT SERVER FOR BIOLOGY 2023:2023.02.01.526664. [PMID: 37205406 PMCID: PMC10187172 DOI: 10.1101/2023.02.01.526664] [Citation(s) in RCA: 10] [Impact Index Per Article: 10.0] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/21/2023]
Abstract
High-density, integrated silicon electrodes have begun to transform systems neuroscience, by enabling large-scale neural population recordings with single cell resolution. Existing technologies, however, have provided limited functionality in nonhuman primate species such as macaques, which offer close models of human cognition and behavior. Here, we report the design, fabrication, and performance of Neuropixels 1.0-NHP, a high channel count linear electrode array designed to enable large-scale simultaneous recording in superficial and deep structures within the macaque or other large animal brain. These devices were fabricated in two versions: 4416 electrodes along a 45 mm shank, and 2496 along a 25 mm shank. For both versions, users can programmatically select 384 channels, enabling simultaneous multi-area recording with a single probe. We demonstrate recording from over 3000 single neurons within a session, and simultaneous recordings from over 1000 neurons using multiple probes. This technology represents a significant increase in recording access and scalability relative to existing technologies, and enables new classes of experiments involving fine-grained electrophysiological characterization of brain areas, functional connectivity between cells, and simultaneous brain-wide recording at scale.
Collapse
|
2
|
Sensing and Stimulation Applications of Carbon Nanomaterials in Implantable Brain-Computer Interface. Int J Mol Sci 2023; 24:ijms24065182. [PMID: 36982255 PMCID: PMC10048878 DOI: 10.3390/ijms24065182] [Citation(s) in RCA: 4] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/17/2022] [Revised: 02/23/2023] [Accepted: 02/28/2023] [Indexed: 03/11/2023] Open
Abstract
Implantable brain–computer interfaces (BCIs) are crucial tools for translating basic neuroscience concepts into clinical disease diagnosis and therapy. Among the various components of the technological chain that increases the sensing and stimulation functions of implanted BCI, the interface materials play a critical role. Carbon nanomaterials, with their superior electrical, structural, chemical, and biological capabilities, have become increasingly popular in this field. They have contributed significantly to advancing BCIs by improving the sensor signal quality of electrical and chemical signals, enhancing the impedance and stability of stimulating electrodes, and precisely modulating neural function or inhibiting inflammatory responses through drug release. This comprehensive review provides an overview of carbon nanomaterials’ contributions to the field of BCI and discusses their potential applications. The topic is broadened to include the use of such materials in the field of bioelectronic interfaces, as well as the potential challenges that may arise in future implantable BCI research and development. By exploring these issues, this review aims to provide insight into the exciting developments and opportunities that lie ahead in this rapidly evolving field.
Collapse
|
3
|
Thielen B, Xu H, Fujii T, Rangwala SD, Jiang W, Lin M, Kammen A, Liu C, Selvan P, Song D, Mack WJ, Meng E. Making a case for endovascular approaches for neural recording and stimulation. J Neural Eng 2023; 20:10.1088/1741-2552/acb086. [PMID: 36603221 PMCID: PMC9928900 DOI: 10.1088/1741-2552/acb086] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/22/2022] [Accepted: 01/05/2023] [Indexed: 01/06/2023]
Abstract
There are many electrode types for recording and stimulating neural tissue, most of which necessitate direct contact with the target tissue. These electrodes range from large, scalp electrodes which are used to non-invasively record averaged, low frequency electrical signals from large areas/volumes of the brain, to penetrating microelectrodes which are implanted directly into neural tissue and interface with one or a few neurons. With the exception of scalp electrodes (which provide very low-resolution recordings), each of these electrodes requires a highly invasive, open brain surgical procedure for implantation, which is accompanied by significant risk to the patient. To mitigate this risk, a minimally invasive endovascular approach can be used. Several types of endovascular electrodes have been developed to be delivered into the blood vessels in the brain via a standard catheterization procedure. In this review, the existing body of research on the development and application of endovascular electrodes is presented. The capabilities of each of these endovascular electrodes is compared to commonly used direct-contact electrodes to demonstrate the relative efficacy of the devices. Potential clinical applications of endovascular recording and stimulation and the advantages of endovascular versus direct-contact approaches are presented.
Collapse
Affiliation(s)
- Brianna Thielen
- Department of Biomedical Engineering, University of Southern California, Los Angeles, CA, USA
| | - Huijing Xu
- Department of Biomedical Engineering, University of Southern California, Los Angeles, CA, USA
| | - Tatsuhiro Fujii
- Department of Neurological Surgery, Keck School of Medicine, University of Southern California, Los Angeles, CA, USA
| | - Shivani D. Rangwala
- Department of Neurological Surgery, Keck School of Medicine, University of Southern California, Los Angeles, CA, USA
| | - Wenxuan Jiang
- Department of Biomedical Engineering, University of Southern California, Los Angeles, CA, USA
| | - Michelle Lin
- Department of Neurological Surgery, Keck School of Medicine, University of Southern California, Los Angeles, CA, USA
| | - Alexandra Kammen
- Department of Neurological Surgery, Keck School of Medicine, University of Southern California, Los Angeles, CA, USA
| | - Charles Liu
- Department of Neurological Surgery, Keck School of Medicine, University of Southern California, Los Angeles, CA, USA,Neurorestoration Center, University of Southern California, Los Angeles, CA, USA
| | - Pradeep Selvan
- The Lundquist Institute for Biomedical Innovation, Torrance, CA, USA
| | - Dong Song
- Department of Biomedical Engineering, University of Southern California, Los Angeles, CA, USA
| | - William J. Mack
- Department of Neurological Surgery, Keck School of Medicine, University of Southern California, Los Angeles, CA, USA
| | - Ellis Meng
- Department of Biomedical Engineering, University of Southern California, Los Angeles, CA, USA
| |
Collapse
|
4
|
McGlynn E, Walton F, Das R, Heidari H. Neural microprobe modelling and microfabrication for improved implantation and mechanical failure mitigation. PHILOSOPHICAL TRANSACTIONS. SERIES A, MATHEMATICAL, PHYSICAL, AND ENGINEERING SCIENCES 2022; 380:20210007. [PMID: 35658676 PMCID: PMC9168446 DOI: 10.1098/rsta.2021.0007] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/03/2023]
Abstract
Careful design and material selection are the most beneficial strategies to ensure successful implantation and mitigate the failure of a neural probe in the long term. In order to realize a fully flexible implantable system, the probe should be easily manipulated by neuroscientists, with the potential to bend up to 90°. This paper investigates the impact of material choice, probe geometry, and crucially, implantation angle on implantation success through finite-element method simulations in COMSOL Multiphysics followed by cleanroom microfabrication. The designs introduced in this paper were fabricated using two polyimides: (i) PI-2545 as a release layer and (ii) photodefinable HD-4110 as the probe substrate. Four different designs were microfabricated, and the implantation tests were compared between an agarose brain phantom and lamb brain samples. The probes were scanned in a 7 T PharmaScan MRI coil to investigate potential artefacts. From the simulation, a triangular base and 50 µm polymer thickness were identified as the optimum design, which produced a probe 57.7 µm thick when fabricated. The probes exhibit excellent flexibility, exemplified in three-point bending tests performed with a DAGE 4000Plus. Successful implantation is possible for a range of angles between 30° and 90°. This article is part of the theme issue 'Advanced neurotechnologies: translating innovation for health and well-being'.
Collapse
Affiliation(s)
- Eve McGlynn
- Microelectronics Lab (meLAB), James Watt School of Engineering, University of Glasgow, Glasgow G12 8QQ, UK
| | - Finlay Walton
- Microelectronics Lab (meLAB), James Watt School of Engineering, University of Glasgow, Glasgow G12 8QQ, UK
| | - Rupam Das
- Microelectronics Lab (meLAB), James Watt School of Engineering, University of Glasgow, Glasgow G12 8QQ, UK
| | - Hadi Heidari
- Microelectronics Lab (meLAB), James Watt School of Engineering, University of Glasgow, Glasgow G12 8QQ, UK
| |
Collapse
|
5
|
Frontal neurons driving competitive behaviour and ecology of social groups. Nature 2022; 603:661-666. [PMID: 35296863 DOI: 10.1038/s41586-021-04000-5] [Citation(s) in RCA: 4] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/04/2020] [Accepted: 09/07/2021] [Indexed: 12/27/2022]
Abstract
Competitive interactions have a vital role in the ecology of most animal species1-3 and powerfully influence the behaviour of groups4,5. To succeed, individuals must exert effort based on not only the resources available but also the social rank and behaviour of other group members2,6,7. The single-cellular mechanisms that precisely drive competitive interactions or the behaviour of social groups, however, remain poorly understood. Here we developed a naturalistic group paradigm in which large cohorts of mice competitively foraged for food as we wirelessly tracked neuronal activities across thousands of unique interactions. By following the collective behaviour of the groups, we found neurons in the anterior cingulate that adaptively represented the social rank of the animals in relation to others. Although social rank was closely behaviourally linked to success, these cells disambiguated the relative rank of the mice from their competitive behaviour, and incorporated information about the resources available, the environment, and past success of the mice to influence their decisions. Using multiclass models, we show how these neurons tracked other individuals within the group and accurately predicted upcoming success. Using neuromodulation techniques, we also show how the neurons conditionally influenced competitive effort-increasing the effort of the animals only when they were more dominant to their groupmates and decreasing it when they were subordinate-effects that were not observed in other frontal lobe areas. Together, these findings reveal cingulate neurons that serve to adaptively drive competitive interactions and a putative process that could intermediate the social and economic behaviour of groups.
Collapse
|
6
|
Chandrasekaran S, Fifer M, Bickel S, Osborn L, Herrero J, Christie B, Xu J, Murphy RKJ, Singh S, Glasser MF, Collinger JL, Gaunt R, Mehta AD, Schwartz A, Bouton CE. Historical perspectives, challenges, and future directions of implantable brain-computer interfaces for sensorimotor applications. Bioelectron Med 2021; 7:14. [PMID: 34548098 PMCID: PMC8456563 DOI: 10.1186/s42234-021-00076-6] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/30/2021] [Accepted: 08/29/2021] [Indexed: 11/10/2022] Open
Abstract
Almost 100 years ago experiments involving electrically stimulating and recording from the brain and the body launched new discoveries and debates on how electricity, movement, and thoughts are related. Decades later the development of brain-computer interface technology began, which now targets a wide range of applications. Potential uses include augmentative communication for locked-in patients and restoring sensorimotor function in those who are battling disease or have suffered traumatic injury. Technical and surgical challenges still surround the development of brain-computer technology, however, before it can be widely deployed. In this review we explore these challenges, historical perspectives, and the remarkable achievements of clinical study participants who have bravely forged new paths for future beneficiaries.
Collapse
Affiliation(s)
- Santosh Chandrasekaran
- Neural Bypass and Brain Computer Interface Laboratory, Feinstein Institutes for Medical Research, Northwell Health, Manhasset, NY, USA
| | - Matthew Fifer
- Research and Exploratory Development Department, Johns Hopkins University Applied Physics Laboratory, Laurel, MD, USA
| | - Stephan Bickel
- The Human Brain Mapping Laboratory, Feinstein Institutes for Medical Research, Northwell Health, Manhasset, NY, USA
- Department of Neurosurgery, Barbara Zucker School of Medicine at Hofstra/Northwell, Manhasset, NY, USA
- Department of Neurology, Donald and Barbara Zucker School of Medicine at Hofstra/Northwell, Manhasset, NY, USA
| | - Luke Osborn
- Research and Exploratory Development Department, Johns Hopkins University Applied Physics Laboratory, Laurel, MD, USA
| | - Jose Herrero
- The Human Brain Mapping Laboratory, Feinstein Institutes for Medical Research, Northwell Health, Manhasset, NY, USA
| | - Breanne Christie
- Research and Exploratory Development Department, Johns Hopkins University Applied Physics Laboratory, Laurel, MD, USA
| | - Junqian Xu
- Departments of Radiology and Psychiatry, Baylor College of Medicine, Houston, TX, USA
| | - Rory K J Murphy
- Department of Neurosurgery, Barrow Neurological Institute, St. Joseph's Hospital and Medical Center, Phoenix, AZ, USA
| | - Sandeep Singh
- Good Shepherd Rehabilitation Hospital, Allentown, PA, USA
| | - Matthew F Glasser
- Departments of Radiology and Neuroscience, Washington University in St Louis, Saint Louis, MO, USA
| | - Jennifer L Collinger
- Rehabilitation Neural Engineering Labs, University of Pittsburgh, Pittsburgh, PA, USA
- Department of Physical Medicine and Rehabilitation, University of Pittsburgh, Pittsburgh, PA, USA
- Department of Bioengineering, University of Pittsburgh, Pittsburgh, PA, USA
- Center for the Neural Basis of Cognition, University of Pittsburgh, Pittsburgh, PA, USA
| | - Robert Gaunt
- Rehabilitation Neural Engineering Labs, University of Pittsburgh, Pittsburgh, PA, USA
- Department of Physical Medicine and Rehabilitation, University of Pittsburgh, Pittsburgh, PA, USA
- Department of Bioengineering, University of Pittsburgh, Pittsburgh, PA, USA
- Center for the Neural Basis of Cognition, University of Pittsburgh, Pittsburgh, PA, USA
| | - Ashesh D Mehta
- The Human Brain Mapping Laboratory, Feinstein Institutes for Medical Research, Northwell Health, Manhasset, NY, USA
- Department of Neurosurgery, Barbara Zucker School of Medicine at Hofstra/Northwell, Manhasset, NY, USA
| | - Andrew Schwartz
- McGowan Institute of Regenerative Medicine, University of Pittsburgh, Pittsburgh, PA, USA
| | - Chad E Bouton
- Neural Bypass and Brain Computer Interface Laboratory, Feinstein Institutes for Medical Research, Northwell Health, Manhasset, NY, USA.
- Department of Molecular Medicine, Donald and Barbara Zucker School of Medicine at Hofstra/Northwell, Manhasset, NY, USA.
| |
Collapse
|
7
|
Intracortical Microelectrode Array Unit Yield under Chronic Conditions: A Comparative Evaluation. MICROMACHINES 2021; 12:mi12080972. [PMID: 34442594 PMCID: PMC8400387 DOI: 10.3390/mi12080972] [Citation(s) in RCA: 14] [Impact Index Per Article: 4.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 05/21/2021] [Revised: 08/10/2021] [Accepted: 08/12/2021] [Indexed: 01/01/2023]
Abstract
While microelectrode arrays (MEAs) offer the promise of elucidating functional neural circuitry and serve as the basis for a cortical neuroprosthesis, the challenge of designing and demonstrating chronically reliable technology remains. Numerous studies report “chronic” data but the actual time spans and performance measures corresponding to the experimental work vary. In this study, we reviewed the experimental durations that constitute chronic studies across a range of MEA types and animal species to gain an understanding of the widespread variability in reported study duration. For rodents, which are the most commonly used animal model in chronic studies, we examined active electrode yield (AEY) for different array types as a means to contextualize the study duration variance, as well as investigate and interpret the performance of custom devices in comparison to conventional MEAs. We observed wide-spread variance within species for the chronic implantation period and an AEY that decayed linearly in rodent models that implanted commercially-available devices. These observations provide a benchmark for comparing the performance of new technologies and highlight the need for consistency in chronic MEA studies. Additionally, to fully derive performance under chronic conditions, the duration of abiotic failure modes, biological processes induced by indwelling probes, and intended application of the device are key determinants.
Collapse
|
8
|
Francoeur MJ, Tang T, Fakhraei L, Wu X, Hulyalkar S, Cramer J, Buscher N, Ramanathan DR. Chronic, Multi-Site Recordings Supported by Two Low-Cost, Stationary Probe Designs Optimized to Capture Either Single Unit or Local Field Potential Activity in Behaving Rats. Front Psychiatry 2021; 12:678103. [PMID: 34421671 PMCID: PMC8374626 DOI: 10.3389/fpsyt.2021.678103] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 03/08/2021] [Accepted: 06/21/2021] [Indexed: 11/13/2022] Open
Abstract
Rodent models of cognitive behavior have greatly contributed to our understanding of human neuropsychiatric disorders. However, to elucidate the neurobiological underpinnings of such disorders or impairments, animal models are more useful when paired with methods for measuring brain function in awake, behaving animals. Standard tools used for systems-neuroscience level investigations are not optimized for large-scale and high-throughput behavioral battery testing due to various factors including cost, time, poor longevity, and selective targeting limited to measuring only a few brain regions at a time. Here we describe two different "user-friendly" methods for building extracellular electrophysiological probes that can be used to measure either single units or local field potentials in rats performing cognitive tasks. Both probe designs leverage several readily available, yet affordable, commercial products to facilitate ease of production and offer maximum flexibility in terms of brain-target locations that can be scalable (32-64 channels) based on experimental needs. Our approach allows neural activity to be recorded simultaneously with behavior and compared between micro (single unit) and more macro (local field potentials) levels of brain activity in order to gain a better understanding of how local brain regions and their connected networks support cognitive functions in rats. We believe our novel probe designs make collecting electrophysiology data easier and will begin to fill the gap in knowledge between basic and clinical research.
Collapse
Affiliation(s)
- Miranda J. Francoeur
- Mental Health Service, VA San Diego Healthcare System, San Diego, CA, United States
- Department of Psychiatry, University of California, San Diego, San Diego, CA, United States
| | - Tianzhi Tang
- Mental Health Service, VA San Diego Healthcare System, San Diego, CA, United States
- Department of Psychiatry, University of California, San Diego, San Diego, CA, United States
| | - Leila Fakhraei
- Mental Health Service, VA San Diego Healthcare System, San Diego, CA, United States
- Department of Psychiatry, University of California, San Diego, San Diego, CA, United States
| | - Xuanyu Wu
- Mental Health Service, VA San Diego Healthcare System, San Diego, CA, United States
- Department of Psychiatry, University of California, San Diego, San Diego, CA, United States
| | - Sidharth Hulyalkar
- Mental Health Service, VA San Diego Healthcare System, San Diego, CA, United States
- Department of Psychiatry, University of California, San Diego, San Diego, CA, United States
| | - Jessica Cramer
- Mental Health Service, VA San Diego Healthcare System, San Diego, CA, United States
- Department of Psychiatry, University of California, San Diego, San Diego, CA, United States
| | - Nathalie Buscher
- Mental Health Service, VA San Diego Healthcare System, San Diego, CA, United States
- Department of Psychiatry, University of California, San Diego, San Diego, CA, United States
| | - Dhakshin R. Ramanathan
- Mental Health Service, VA San Diego Healthcare System, San Diego, CA, United States
- Department of Psychiatry, University of California, San Diego, San Diego, CA, United States
| |
Collapse
|
9
|
Buchwald D, Scherberger H. Visually and Tactually Guided Grasps Lead to Different Neuronal Activity in Non-human Primates. Front Neurosci 2021; 15:679910. [PMID: 34349616 PMCID: PMC8326571 DOI: 10.3389/fnins.2021.679910] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/12/2021] [Accepted: 06/18/2021] [Indexed: 11/13/2022] Open
Abstract
Movements are defining characteristics of all behaviors. Animals walk around, move their eyes to explore the world or touch structures to learn more about them. So far we only have some basic understanding of how the brain generates movements, especially when we want to understand how different areas of the brain interact with each other. In this study we investigated the influence of sensory object information on grasp planning in four different brain areas involved in vision, touch, movement planning, and movement generation in the parietal, somatosensory, premotor and motor cortex. We trained one monkey to grasp objects that he either saw or touched beforehand while continuously recording neural spiking activity with chronically implanted floating multi-electrode arrays. The animal was instructed to sit in the dark and either look at a shortly illuminated object or reach out and explore the object with his hand in the dark before lifting it up. In a first analysis we confirmed that the animal not only memorizes the object in both tasks, but also applies an object-specific grip type, independent of the sensory modality. In the neuronal population, we found a significant difference in the number of tuned units for sensory modalities during grasp planning that persisted into grasp execution. These differences were sufficient to enable a classifier to decode the object and sensory modality in a single trial exclusively from neural population activity. These results give valuable insights in how different brain areas contribute to the preparation of grasp movement and how different sensory streams can lead to distinct neural activity while still resulting in the same action execution.
Collapse
Affiliation(s)
- Daniela Buchwald
- Neurobiology Laboratory, Deutsches Primatenzentrum GmbH, Göttingen, Germany
- Faculty of Biology and Psychology, University of Goettingen, Göttingen, Germany
| | - Hansjörg Scherberger
- Neurobiology Laboratory, Deutsches Primatenzentrum GmbH, Göttingen, Germany
- Faculty of Biology and Psychology, University of Goettingen, Göttingen, Germany
| |
Collapse
|
10
|
Buchwald D, Schaffelhofer S, Dörge M, Dann B, Scherberger H. A Turntable Setup for Testing Visual and Tactile Grasping Movements in Non-human Primates. Front Behav Neurosci 2021; 15:648483. [PMID: 34113241 PMCID: PMC8185519 DOI: 10.3389/fnbeh.2021.648483] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/31/2020] [Accepted: 04/19/2021] [Indexed: 11/13/2022] Open
Abstract
Grasping movements are some of the most common movements primates do every day. They are important for social interactions as well as picking up objects or food. Usually, these grasping movements are guided by vision but proprioceptive and haptic inputs contribute greatly. Since grasping behaviors are common and easy to motivate, they represent an ideal task for understanding the role of different brain areas during planning and execution of complex voluntary movements in primates. For experimental purposes, a stable and repeatable presentation of the same object as well as the variation of objects is important in order to understand the neural control of movement generation. This is even more the case when investigating the role of different senses for movement planning, where objects need to be presented in specific sensory modalities. We developed a turntable setup for non-human primates (macaque monkeys) to investigate visually and tactually guided grasping movements with an option to easily exchange objects. The setup consists of a turntable that can fit six different objects and can be exchanged easily during the experiment to increase the number of presented objects. The object turntable is connected to a stepper motor through a belt system to automate rotation and hence object presentation. By increasing the distance between the turntable and the stepper motor, metallic components of the stepper motor are kept at a distance to the actual recording setup, which allows using a magnetic-based data glove to track hand kinematics. During task execution, the animal sits in the dark and is instructed to grasp the object in front of it. Options to turn on a light above the object allow for visual presentation of the objects, while the object can also remain in the dark for exclusive tactile exploration. A red LED is projected onto the object by a one-way mirror that serves as a grasp cue instruction for the animal to start grasping the object. By comparing kinematic data from the magnetic-based data glove with simultaneously recorded neural signals, this setup enables the systematic investigation of neural population activity involved in the neural control of hand grasping movements.
Collapse
Affiliation(s)
- Daniela Buchwald
- Neuroscience Laboratory, Deutsches Primatenzentrum GmbH, Göttingen, Germany
- Faculty of Biology and Psychology, University of Goettingen, Göttingen, Germany
| | | | - Matthias Dörge
- Neuroscience Laboratory, Deutsches Primatenzentrum GmbH, Göttingen, Germany
| | - Benjamin Dann
- Neuroscience Laboratory, Deutsches Primatenzentrum GmbH, Göttingen, Germany
| | - Hansjörg Scherberger
- Neuroscience Laboratory, Deutsches Primatenzentrum GmbH, Göttingen, Germany
- Faculty of Biology and Psychology, University of Goettingen, Göttingen, Germany
| |
Collapse
|
11
|
Thielen B, Meng E. A comparison of insertion methods for surgical placement of penetrating neural interfaces. J Neural Eng 2021; 18:10.1088/1741-2552/abf6f2. [PMID: 33845469 PMCID: PMC8600966 DOI: 10.1088/1741-2552/abf6f2] [Citation(s) in RCA: 12] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/14/2020] [Accepted: 04/12/2021] [Indexed: 02/07/2023]
Abstract
Many implantable electrode arrays exist for the purpose of stimulating or recording electrical activity in brain, spinal, or peripheral nerve tissue, however most of these devices are constructed from materials that are mechanically rigid. A growing body of evidence suggests that the chronic presence of these rigid probes in the neural tissue causes a significant immune response and glial encapsulation of the probes, which in turn leads to gradual increase in distance between the electrodes and surrounding neurons. In recording electrodes, the consequence is the loss of signal quality and, therefore, the inability to collect electrophysiological recordings long term. In stimulation electrodes, higher current injection is required to achieve a comparable response which can lead to tissue and electrode damage. To minimize the impact of the immune response, flexible neural probes constructed with softer materials have been developed. These flexible probes, however, are often not strong enough to be inserted on their own into the tissue, and instead fail via mechanical buckling of the shank under the force of insertion. Several strategies have been developed to allow the insertion of flexible probes while minimizing tissue damage. It is critical to keep these strategies in mind during probe design in order to ensure successful surgical placement. In this review, existing insertion strategies will be presented and evaluated with respect to surgical difficulty, immune response, ability to reach the target tissue, and overall limitations of the technique. Overall, the majority of these insertion techniques have only been evaluated for the insertion of a single probe and do not quantify the accuracy of probe placement. More work needs to be performed to evaluate and optimize insertion methods for accurate placement of devices and for devices with multiple probes.
Collapse
Affiliation(s)
- Brianna Thielen
- Department of Biomedical Engineering, University of Southern California, Los Angeles, CA, United States of America
| | - Ellis Meng
- Department of Biomedical Engineering, University of Southern California, Los Angeles, CA, United States of America
| |
Collapse
|
12
|
Carnicer-Lombarte A, Chen ST, Malliaras GG, Barone DG. Foreign Body Reaction to Implanted Biomaterials and Its Impact in Nerve Neuroprosthetics. Front Bioeng Biotechnol 2021; 9:622524. [PMID: 33937212 PMCID: PMC8081831 DOI: 10.3389/fbioe.2021.622524] [Citation(s) in RCA: 132] [Impact Index Per Article: 44.0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/28/2020] [Accepted: 03/19/2021] [Indexed: 12/04/2022] Open
Abstract
The implantation of any foreign material into the body leads to the development of an inflammatory and fibrotic process-the foreign body reaction (FBR). Upon implantation into a tissue, cells of the immune system become attracted to the foreign material and attempt to degrade it. If this degradation fails, fibroblasts envelop the material and form a physical barrier to isolate it from the rest of the body. Long-term implantation of medical devices faces a great challenge presented by FBR, as the cellular response disrupts the interface between implant and its target tissue. This is particularly true for nerve neuroprosthetic implants-devices implanted into nerves to address conditions such as sensory loss, muscle paralysis, chronic pain, and epilepsy. Nerve neuroprosthetics rely on tight interfacing between nerve tissue and electrodes to detect the tiny electrical signals carried by axons, and/or electrically stimulate small subsets of axons within a nerve. Moreover, as advances in microfabrication drive the field to increasingly miniaturized nerve implants, the need for a stable, intimate implant-tissue interface is likely to quickly become a limiting factor for the development of new neuroprosthetic implant technologies. Here, we provide an overview of the material-cell interactions leading to the development of FBR. We review current nerve neuroprosthetic technologies (cuff, penetrating, and regenerative interfaces) and how long-term function of these is limited by FBR. Finally, we discuss how material properties (such as stiffness and size), pharmacological therapies, or use of biodegradable materials may be exploited to minimize FBR to nerve neuroprosthetic implants and improve their long-term stability.
Collapse
Affiliation(s)
- Alejandro Carnicer-Lombarte
- Electrical Engineering Division, Department of Engineering, University of Cambridge, Cambridge, United Kingdom
| | - Shao-Tuan Chen
- Electrical Engineering Division, Department of Engineering, University of Cambridge, Cambridge, United Kingdom
| | - George G. Malliaras
- Electrical Engineering Division, Department of Engineering, University of Cambridge, Cambridge, United Kingdom
| | - Damiano G. Barone
- Electrical Engineering Division, Department of Engineering, University of Cambridge, Cambridge, United Kingdom
- Division of Neurosurgery, Department of Clinical Neurosciences, University of Cambridge, Cambridge, United Kingdom
| |
Collapse
|
13
|
Kundu A, McCoy L, Azim N, Nguyen H, Didier CM, Ausaf T, Sharma AD, Curley JL, Moore MJ, Rajaraman S. Fabrication and Characterization of 3D Printed, 3D Microelectrode Arrays for Interfacing with a Peripheral Nerve-on-a-Chip. ACS Biomater Sci Eng 2020; 7:3018-3029. [PMID: 34275292 DOI: 10.1021/acsbiomaterials.0c01184] [Citation(s) in RCA: 19] [Impact Index Per Article: 4.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/28/2022]
Abstract
We present a nontraditional fabrication technique for the realization of three-dimensional (3D) microelectrode arrays (MEAs) capable of interfacing with 3D cellular networks in vitro. The technology uses cost-effective makerspace microfabrication techniques to fabricate the 3D MEAs with 3D printed base structures with the metallization of the microtowers and conductive traces being performed by stencil mask evaporation techniques. A biocompatible lamination layer insulates the traces for realization of 3D microtower MEAs (250 μm base diameter, 400 μm height). The process has additionally been extended to realize smaller electrodes (30 μm × 30 μm) at a height of 400 μm atop the 3D microtower using laser micromachining of an additional silicon dioxide (SiO2) insulation layer. A 3D microengineered, nerve-on-a-chip in vitro model for recording and stimulating electrical activity of dorsal root ganglion (DRG) cells has further been integrated with the 3D MEA. We have characterized the 3D electrodes for electrical, chemical, electrochemical, biological, and chip hydration stability performance metrics. A decrease in impedance from 1.8 kΩ to 670 Ω for the microtower electrodes and 55 to 39 kΩ for the 30 μm × 30 μm microelectrodes can be observed for an electrophysiologically relevant frequency of 1 kHz upon platinum electroless plating. Biocompatibility assays on the components of the system resulted in a large range (∼3%-70% live cells), depending on the components. Fourier-transform infrared (FTIR) spectra of the resin material start to reveal possible compositional clues for the resin, and the hydration stability is demonstrated in in-vitro-like conditions for 30 days. The fabricated 3D MEAs are rapidly produced with minimal usage of a cleanroom and are fully functional for electrical interrogation of the 3D organ-on-a-chip models for high-throughput of pharmaceutical screening and toxicity testing of compounds in vitro.
Collapse
Affiliation(s)
- Avra Kundu
- NanoScience Technology Center (NSTC), University of Central Florida, Orlando, Florida 32816, United States
| | - Laurie McCoy
- AxoSim, Inc., New Orleans, Louisiana 70112, United States
| | - Nilab Azim
- NanoScience Technology Center (NSTC), University of Central Florida, Orlando, Florida 32816, United States.,Department of Chemistry, University of Central Florida, Orlando, Florida 32816, United States
| | - Hieu Nguyen
- AxoSim, Inc., New Orleans, Louisiana 70112, United States
| | - Charles M Didier
- NanoScience Technology Center (NSTC), University of Central Florida, Orlando, Florida 32816, United States.,Burnett School of Biomedical Sciences, University of Central Florida, Orlando, Florida 32827, United States
| | - Tariq Ausaf
- NanoScience Technology Center (NSTC), University of Central Florida, Orlando, Florida 32816, United States.,Department of Electrical & Computer Engineering, University of Central Florida, Orlando, Florida 32826, United States
| | - Anup D Sharma
- AxoSim, Inc., New Orleans, Louisiana 70112, United States
| | - J Lowry Curley
- AxoSim, Inc., New Orleans, Louisiana 70112, United States
| | - Michael J Moore
- AxoSim, Inc., New Orleans, Louisiana 70112, United States.,Department of Biomedical Engineering, Tulane University, New Orleans, Louisiana 70118, United States
| | - Swaminathan Rajaraman
- NanoScience Technology Center (NSTC), University of Central Florida, Orlando, Florida 32816, United States.,Burnett School of Biomedical Sciences, University of Central Florida, Orlando, Florida 32827, United States.,Department of Electrical & Computer Engineering, University of Central Florida, Orlando, Florida 32826, United States.,Department of Materials Science & Engineering, University of Central Florida, Orlando, Florida 32826, United States
| |
Collapse
|
14
|
Brosch M, Deckert M, Rathi S, Takagaki K, Weidner T, Ohl FW, Schmidt B, Lippert MT. An optically transparent multi-electrode array for combined electrophysiology and optophysiology at the mesoscopic scale. J Neural Eng 2020; 17:046014. [PMID: 32705997 DOI: 10.1088/1741-2552/aba1a4] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/12/2022]
Abstract
OBJECTIVE A number of tissue penetrating opto-electrodes to simultaneously record and optogenetically influence brain activity have been developed. For experiments at the surface of the brain, such as electrocorticogram (ECoG) recordings and surface optogenetics, fewer devices have been described and no device has found widespread adoption for neuroscientific experiments. One issue slowing adoption is the complexity and fragility of existing devices, typically based on transparent electrode materials like graphene and indium-tin oxide (ITO). We focused here on improving existing processes based on metal traces and polyimide (PI), which produce more robust and cost-effective devices, to develop a multi-electrode array for optophysiology. APPROACH The most widely used substrate material for surface electrodes, PI, has seen little use for optophysiologicalμECoG/ECoG arrays. This is due to its lack of transparency at optogenetically relevant short wavelengths. Here we use very thin layers of PI in combination with chrome-gold-platinum electrodes to achieve the necessary substrate transparency and high mechanical flexibility in a device that still rejects light artifacts well. MAIN RESULTS The manufactured surface arrays have a thickness of only 6.5 µm, resulting in 80% transparency for blue light. We demonstrate immunity against opto-electric artifacts, long term stability and biocompatibility as well as suitability for optical voltage imaging. The biocompatible arrays are capable of recording stable ECoGs over months without any measurable degradation and can be used to map the tonotopic organization of the curved rodent auditory cortex. SIGNIFICANCE Our novel probes combine proven materials and processing steps to create optically near-transparent electrode arrays with superior longevity. In contrast to previous opto-electrodes, our probes are simple to manufacture, robust, offer long-term stability, and are a practical engineering solution for optophysiological experiments not requiring transparency of the electrode sites themselves.
Collapse
Affiliation(s)
- Marcel Brosch
- Systems Physiology of Learning, Leibniz Institute for Neurobiology, Magdeburg, Germany
| | | | | | | | | | | | | | | |
Collapse
|
15
|
Vu PP, Chestek CA, Nason SR, Kung TA, Kemp SW, Cederna PS. The future of upper extremity rehabilitation robotics: research and practice. Muscle Nerve 2020; 61:708-718. [PMID: 32413247 PMCID: PMC7868083 DOI: 10.1002/mus.26860] [Citation(s) in RCA: 8] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/05/2019] [Revised: 03/03/2020] [Accepted: 03/03/2020] [Indexed: 01/14/2023]
Abstract
The loss of upper limb motor function can have a devastating effect on people's lives. To restore upper limb control and functionality, researchers and clinicians have developed interfaces to interact directly with the human body's motor system. In this invited review, we aim to provide details on the peripheral nerve interfaces and brain-machine interfaces that have been developed in the past 30 years for upper extremity control, and we highlight the challenges that still remain to transition the technology into the clinical market. The findings show that peripheral nerve interfaces and brain-machine interfaces have many similar characteristics that enable them to be concurrently developed. Decoding neural information from both interfaces may lead to novel physiological models that may one day fully restore upper limb motor function for a growing patient population.
Collapse
Affiliation(s)
- Philip P. Vu
- Department of Biomedical Engineering, University of Michigan, Ann Arbor, Michigan
- Section of Plastic Surgery, University of Michigan, Ann Arbor, Michigan
| | - Cynthia A. Chestek
- Department of Biomedical Engineering, University of Michigan, Ann Arbor, Michigan
- Robotics Institute, University of Michigan, Ann Arbor, Michigan
- Department of Electrical Engineering and Computer Science, University of Michigan, Ann Arbor, Michigan
- Neuroscience Graduate Program, University of Michigan, Ann Arbor, Michigan
| | - Samuel R. Nason
- Department of Biomedical Engineering, University of Michigan, Ann Arbor, Michigan
| | - Theodore A. Kung
- Section of Plastic Surgery, University of Michigan, Ann Arbor, Michigan
| | - Stephen W.P. Kemp
- Department of Biomedical Engineering, University of Michigan, Ann Arbor, Michigan
- Section of Plastic Surgery, University of Michigan, Ann Arbor, Michigan
| | - Paul S. Cederna
- Department of Biomedical Engineering, University of Michigan, Ann Arbor, Michigan
- Section of Plastic Surgery, University of Michigan, Ann Arbor, Michigan
| |
Collapse
|
16
|
Localization of movable electrodes in a multi-electrode microdrive in nonhuman primates. J Neurosci Methods 2019; 330:108505. [PMID: 31711885 DOI: 10.1016/j.jneumeth.2019.108505] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/03/2019] [Revised: 11/04/2019] [Accepted: 11/07/2019] [Indexed: 11/24/2022]
Abstract
BACKGROUND Recently, large-scale semi-chronic recording systems have been developed, unique in their capability to record simultaneously from multiple individually moveable electrodes. As these recording systems can cover a large area, knowledge of the exact location of each individual electrode is crucial. Currently, the only method of keeping track of electrode depth and thus location is through detailed notebook keeping on neural activity. NEW METHOD We have improved the electrode localization by combining pre- and postoperative anatomical magnetic resonance imaging (MRI) scans with high resolution computed tomography (CT) scans throughout the experiment, and validated our method by comparing the resulting location estimates with traditional notebook-keeping. Finally, the actual location of a selection of electrodes was marked at the end of the experiment by creating small metallic depositions using electrical stimulation, and thereby made visible on MRI. RESULTS Combining CT scans with a high resolution, artefact reducing sequence during the experiment with a preoperative MRI scan provides crucial information about the exact electrode location of multielectrode arrays with individually moveable electrodes. COMPARISON WITH EXISTING METHODS The information obtained from the hybrid CT-MR image and the notes on spiking activity showed a similar pattern, with the clear advantage of the visualization of the exact position of the electrodes using our method. CONCLUSIONS The described technique allows for a precise anatomical identification of the recorded brain areas and thus to draw strong conclusions about the role of each targeted cortical area in the behavior under study.
Collapse
|
17
|
Ferguson M, Sharma D, Ross D, Zhao F. A Critical Review of Microelectrode Arrays and Strategies for Improving Neural Interfaces. Adv Healthc Mater 2019; 8:e1900558. [PMID: 31464094 PMCID: PMC6786932 DOI: 10.1002/adhm.201900558] [Citation(s) in RCA: 37] [Impact Index Per Article: 7.4] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/30/2019] [Revised: 07/25/2019] [Indexed: 12/19/2022]
Abstract
Though neural interface systems (NISs) can provide a potential solution for mitigating the effects of limb loss and central nervous system damage, the microelectrode array (MEA) component of NISs remains a significant limiting factor to their widespread clinical applications. Several strategies can be applied to MEA designs to increase their biocompatibility. Herein, an overview of NISs and their applications is provided, along with a detailed discussion of strategies for alleviating the foreign body response (FBR) and abnormalities seen at the interface of MEAs and the brain tissue following MEA implantation. Various surface modifications, including natural/synthetic surface coatings, hydrogels, and topography alterations, have shown to be highly successful in improving neural cell adhesion, reducing gliosis, and increasing MEA longevity. Different MEA surface geometries, such as those seen in the Utah and Michigan arrays, can help alleviate the resultant FBR by reducing insertion damage, while providing new avenues for improving MEA recording performance and resolution. Increasing overall flexibility of MEAs as well as reducing their stiffness is also shown to reduce MEA induced micromotion along with FBR severity. By combining multiple different properties into a single MEA, the severity and duration of an FBR postimplantation can be reduced substantially.
Collapse
Affiliation(s)
- Morgan Ferguson
- Department of Biomedical Engineering, Michigan Technological University, 1400 Townsend Dr., Houghton, MI 49931
| | - Dhavan Sharma
- Department of Biomedical Engineering, Michigan Technological University, 1400 Townsend Dr., Houghton, MI 49931
| | - David Ross
- Department of Biomedical Engineering, Michigan Technological University, 1400 Townsend Dr., Houghton, MI 49931
| | - Feng Zhao
- Department of Biomedical Engineering, Michigan Technological University, 1400 Townsend Dr., Houghton, MI 49931
| |
Collapse
|
18
|
Cheng MY, Damalerio RB, Chen W, Rajkumar R, Dawe GS. Ultracompact Multielectrode Array for Neurological Monitoring. SENSORS 2019; 19:s19102286. [PMID: 31108970 PMCID: PMC6567369 DOI: 10.3390/s19102286] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 03/26/2019] [Revised: 05/08/2019] [Accepted: 05/08/2019] [Indexed: 02/01/2023]
Abstract
Patients with paralysis, spinal cord injury, or amputated limbs could benefit from using brain–machine interface technology for communication and neurorehabilitation. In this study, a 32-channel three-dimensional (3D) multielectrode probe array was developed for the neural interface system of a brain–machine interface to monitor neural activity. A novel microassembly technique involving lead transfer was used to prevent misalignment in the bonding plane during the orthogonal assembly of the 3D multielectrode probe array. Standard microassembly and biopackaging processes were utilized to implement the proposed lead transfer technique. The maximum profile of the integrated 3D neural device was set to 0.50 mm above the pia mater to reduce trauma to brain cells. Benchtop tests characterized the electrical impedance of the neural device. A characterization test revealed that the impedance of the 3D multielectrode probe array was on average approximately 0.55 MΩ at a frequency of 1 KHz. Moreover, in vitro cytotoxicity tests verified the biocompatibility of the device. Subsequently, 3D multielectrode probe arrays were implanted in rats and exhibited the capability to record local field potentials and spike signals.
Collapse
Affiliation(s)
- Ming-Yuan Cheng
- Institute of Microelectronics, Agency for Science, Technology and Research, Singapore 138634, Singapore.
| | - Ramona B Damalerio
- Institute of Microelectronics, Agency for Science, Technology and Research, Singapore 138634, Singapore.
| | - Weiguo Chen
- Institute of Microelectronics, Agency for Science, Technology and Research, Singapore 138634, Singapore.
| | - Ramamoorthy Rajkumar
- Department of Pharmacology, Yong Loo Lin School of Medicine, National University Health System, National University of Singapore, Singapore 117600, Singapore.
| | - Gavin S Dawe
- Department of Pharmacology, Yong Loo Lin School of Medicine, National University Health System, National University of Singapore, Singapore 117600, Singapore.
| |
Collapse
|
19
|
Dai J, Zhang P, Sun H, Qiao X, Zhao Y, Ma J, Li S, Zhou J, Wang C. Reliability of motor and sensory neural decoding by threshold crossings for intracortical brain-machine interface. J Neural Eng 2019; 16:036011. [PMID: 30822756 DOI: 10.1088/1741-2552/ab0bfb] [Citation(s) in RCA: 13] [Impact Index Per Article: 2.6] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/27/2022]
Abstract
OBJECTIVE For intracortical neurophysiological studies, spike sorting is an important procedure to isolate single units for analyzing specific functions. However, whether spike sorting is necessary or not for neural decoding applications is controversial. Several studies showed that using threshold crossings (TC) instead of spike sorting could also achieve a similar satisfactory performance. However, such studies were limited in similar behavioral tasks, and the neural signal source mainly focused on the motor-related cortical regions. It is not certain if this conclusion is applicable to other situations. Therefore, we compared the performance of TC and spike sorting in neural decoding with more comprehensive paradigms and parameters. APPROACH Two rhesus macaques implanted with Utah or floating microelectrode arrays (FMAs) in motor or sensory-related cortical regions were trained to perform a motor or a sensory task. Data from each monkey were preprocessed with three different schemes: TC, automatic sorting (AS), and manual sorting (MS). A support vector machine was used as the decoder, and the decoding accuracy was used for evaluating the performance of three preprocessing methods. Different neural signal sources, different decoders, and related parameters and decoding stability were further tested to systematically compare three preprocessing methods. MAIN RESULTS TC could achieve a similar (-4.5 RMS threshold) or better (-3.0 RMS threshold) decoding performance compared to the other two sorting methods in the motor or sensory tasks even if the neural signal sources or decoder-related parameters were changed. Moreover, TC was much more stable in neural decoding across sessions and robust to changes of threshold. SIGNIFICANCE Our results indicated that spike-firing patterns could be stably extracted through TC from multiple cortices in both motor and sensory neural decoding applications. Considering the stability of TC, it might be more suitable for neural decoding compared to sorting methods.
Collapse
Affiliation(s)
- Jun Dai
- Department of Neural Engineering and Biological Interdisciplinary Studies, Institute of Military Cognition and Brain Sciences, Academy of Military Medical Sciences, 27 Taiping Rd, Beijing 100850, People's Republic of China
| | | | | | | | | | | | | | | | | |
Collapse
|
20
|
Advances in Penetrating Multichannel Microelectrodes Based on the Utah Array Platform. ADVANCES IN EXPERIMENTAL MEDICINE AND BIOLOGY 2019; 1101:1-40. [PMID: 31729670 DOI: 10.1007/978-981-13-2050-7_1] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 01/10/2023]
Abstract
The Utah electrode array (UEA) and its many derivatives have become a gold standard for high-channel count bi-directional neural interfaces, in particular in human subject applications. The chapter provides a brief overview of leading electrode concepts and the context in which the UEA has to be understood. It goes on to discuss the key advances and developments of the UEA platform in the past 15 years, as well as novel wireless and system integration technologies that will merge into future generations of fully integrated devices. Aspects covered include novel device architectures that allow scaling of channel count and density of electrode contacts, material improvements to substrate, electrode contacts, and encapsulation. Further subjects are adaptations of the UEA platform to support IR and optogenetic simulation as well as an improved understanding of failure modes and methods to test and accelerate degradation in vitro such as to better predict device failure and lifetime in vivo.
Collapse
|
21
|
Effects of Synchronous Electrode Pulses on Neural Recruitment During Multichannel Microstimulation. Sci Rep 2018; 8:13067. [PMID: 30166583 PMCID: PMC6117337 DOI: 10.1038/s41598-018-31247-2] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/15/2018] [Accepted: 08/09/2018] [Indexed: 11/22/2022] Open
Abstract
The recent proliferation of high-density microelectrode arrays has inspired several new applications of electrical microstimulation, including restoration of sensory functions in the visual, auditory, and somatosensory systems. In each case, the goal is to achieve precisely targeted activation of neurons, while patterning the location and timing of stimulation across the array to mimic naturalistic patterns of neural activity. However, when two or more electrodes deliver stimulation pulses at the same time, the electric fields created by each electrode interact. The effects of field interactions on neuronal recruitment depend on several factors, which have been studied extensively at the macro-scale but have been overlooked in the case of high density arrays. Here, we report that field interactions can significantly affect neural recruitment, even with low amplitude stimulation. We created a computational model of peripheral nerve axons to estimate stimulation parameters sufficient to generate neural recruitment during synchronous and asynchronous stimulation on two microelectrodes located within the peripheral nerve. Across a range of stimulus amplitudes, the model predicted that synchronous stimulation on adjacent electrodes (400 µm separation), would recruit 2–3 times more neurons than during asynchronous stimulation. Our results suggest that field interactions should not be ignored when designing multichannel microstimulation paradigms, even at threshold-level stimulus amplitudes.
Collapse
|
22
|
Chen G, Dodson B, Hedges DM, Steffensen SC, Harb JN, Puleo C, Galligan C, Ashe J, Vanfleet RR, Davis RC. Fabrication of High Aspect Ratio Millimeter-Tall Free-Standing Carbon Nanotube-Based Microelectrode Arrays. ACS Biomater Sci Eng 2018; 4:1900-1907. [PMID: 33445345 DOI: 10.1021/acsbiomaterials.8b00038] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/16/2023]
Abstract
Microelectrode arrays of carbon nanotube (CNT)/carbon composite posts with high aspect ratio and millimeter-length were fabricated using carbon-nanotube-templated microfabrication with a sacrificial "hedge". The high aspect ratio, mechanical robustness, and electrical conductivity of these electrodes make them a potential candidate for next-generation neural interfacing. Electrochemical measurements were also demonstrated using an individual CNT post microelectrode with a diameter of 25 μm and a length of 1 mm to perform cyclic voltammetry on both methyl viologen and dopamine in a phosphate-buffered saline solution. In addition to detection of the characteristic peaks, the CNT post microelectrodes show a fast electrochemical response, which may be enabling for in vivo and/or in vitro measurements. The CNT post electrode fabrication process was also integrated with other microfabrication techniques, resulting in individually addressable electrodes.
Collapse
Affiliation(s)
- Guohai Chen
- Department of Physics and Astronomy, Brigham Young University, Provo, Utah 84602, United States
| | - Berg Dodson
- Department of Physics and Astronomy, Brigham Young University, Provo, Utah 84602, United States
| | - David M Hedges
- Department of Psychology and Neuroscience, Brigham Young University, Provo, Utah 84602, United States
| | - Scott C Steffensen
- Department of Psychology and Neuroscience, Brigham Young University, Provo, Utah 84602, United States
| | - John N Harb
- Department of Chemical Engineering, Brigham Young University, Provo, Utah 84602, United States
| | - Chris Puleo
- General Electric Global Research (GE-GR), 1 Research Circle, Niskayuna, New York 12309, United States
| | - Craig Galligan
- General Electric Global Research (GE-GR), 1 Research Circle, Niskayuna, New York 12309, United States
| | - Jeffrey Ashe
- General Electric Global Research (GE-GR), 1 Research Circle, Niskayuna, New York 12309, United States
| | - Richard R Vanfleet
- Department of Physics and Astronomy, Brigham Young University, Provo, Utah 84602, United States
| | - Robert C Davis
- Department of Physics and Astronomy, Brigham Young University, Provo, Utah 84602, United States
| |
Collapse
|
23
|
Ferrea E, Suriya-Arunroj L, Hoehl D, Thomas U, Gail A. Implantable computer-controlled adaptive multielectrode positioning system. J Neurophysiol 2018; 119:1471-1484. [DOI: 10.1152/jn.00504.2017] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/19/2022] Open
Abstract
Acute neuronal recordings performed with metal microelectrodes in nonhuman primates allow investigating the neural substrate of complex cognitive behaviors. Yet the daily reinsertion and positioning of the electrodes prevents recording from many neurons simultaneously, limiting the suitability of these types of recordings for brain-computer interface applications or for large-scale population statistical methods on a trial-by-trial basis. In contrast, chronically implanted multielectrode arrays offer the opportunity to record from many neurons simultaneously, but immovable electrodes prevent optimization of the signal during and after implantation and cause the tissue response to progressively impair the transduced signal quality, thereby limiting the number of different neurons that can be recorded over the lifetime of the implant. Semichronically implanted matrices of electrodes, instead, allow individually movable electrodes in depth and achieve higher channel count compared with acute methods, hence partially overcoming these limitations. Existing semichronic systems with higher channel count lack computerized control of electrode movements, leading to limited user-friendliness and uncertainty in depth positioning. Here we demonstrate a chronically implantable adaptive multielectrode positioning system with detachable drive for computerized depth adjustment of individual electrodes over several millimeters. This semichronic 16-channel system is designed to optimize the simultaneous yield of units in an extended period following implantation since the electrodes can be independently depth adjusted with minimal effort and their signal quality continuously assessed. Importantly, the electrode array is designed to remain within a chronic recording chamber for a prolonged time or can be used for acute recordings with high signal-to-noise ratio in the cerebral cortex of nonhuman primates. NEW & NOTEWORTHY We present a 16-channel motorized, semichronic multielectrode array with individually depth-adjustable electrodes to record in the cerebral cortex of nonhuman primates. Compared with fixed-geometry arrays, this system allows repeated reestablishing of single neuron isolation. Compared with manually adjustable arrays it benefits from computer-controlled positioning. Compared with motorized semichronic systems it allows higher channel counts due to a robotic single actuator approach. Overall the system is designed to optimize the simultaneous yield of units over the course of implantation.
Collapse
Affiliation(s)
- E. Ferrea
- German Primate Center, Sensorimotor Group, Goettingen, Germany
| | | | - D. Hoehl
- Thomas RECORDING, Giessen, Germany
| | | | - A. Gail
- German Primate Center, Sensorimotor Group, Goettingen, Germany
- University of Goettingen, Georg-Elias-Mueller Institute of Psychology, Goettingen, Germany
- Bernstein Center for Computational Neuroscience, Goettingen, Germany
| |
Collapse
|
24
|
Bredeson S, Kanneganti A, Deku F, Cogan S, Romero-Ortega M, Troyk P. Chronic in-vivo testing of a 16-channel implantable wireless neural stimulator. ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY. IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY. ANNUAL INTERNATIONAL CONFERENCE 2018; 2015:1017-20. [PMID: 26736437 DOI: 10.1109/embc.2015.7318537] [Citation(s) in RCA: 16] [Impact Index Per Article: 2.7] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/05/2022]
Abstract
Here, we report on chronic in-vivo testing of a 16-channel wireless floating microelectrode array (WFMA) in a rat sciatic nerve model. Muscle threshold currents, charge injection levels, and charge density were monitored for electrodes of two WFMA devices implanted into animal subjects over a five month period. This type of wireless stimulation device could eliminate problems associated with percutaneous connectors for a variety of neural prostheses and other medical devices.
Collapse
|
25
|
Spearman BS, Desai VH, Mobini S, McDermott MD, Graham JB, Otto KJ, Judy JW, Schmidt CE. Tissue-Engineered Peripheral Nerve Interfaces. ADVANCED FUNCTIONAL MATERIALS 2018; 28:1701713. [PMID: 37829558 PMCID: PMC10569514 DOI: 10.1002/adfm.201701713] [Citation(s) in RCA: 42] [Impact Index Per Article: 7.0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 10/14/2023]
Abstract
Research on neural interfaces has historically concentrated on development of systems for the brain; however, there is increasing interest in peripheral nerve interfaces (PNIs) that could provide benefit when peripheral nerve function is compromised, such as for amputees. Efforts focus on designing scalable and high-performance sensory and motor peripheral nervous system interfaces. Current PNIs face several design challenges such as undersampling of signals from the thousands of axons, nerve-fiber selectivity, and device-tissue integration. To improve PNIs, several researchers have turned to tissue engineering. Peripheral nerve tissue engineering has focused on designing regeneration scaffolds that mimic normal nerve extracellular matrix composition, provide advanced microarchitecture to stimulate cell migration, and have mechanical properties like the native nerve. By combining PNIs with tissue engineering, the goal is to promote natural axon regeneration into the devices to facilitate close contact with electrodes; in contrast, traditional PNIs rely on insertion or placement of electrodes into or around existing nerves, or do not utilize materials to actively facilitate axon regeneration. This review presents the state-of-the-art of PNIs and nerve tissue engineering, highlights recent approaches to combine neural-interface technology and tissue engineering, and addresses the remaining challenges with foreign-body response.
Collapse
Affiliation(s)
- Benjamin S Spearman
- Crayton Pruitt Family Department of Biomedical Engineering, The University of Florida, 1275 Center Dr., BMS Building JG-56, 116131, Gainesville, FL 32611-6131
| | - Vidhi H Desai
- Department of Electrical and Computer Engineering, The University of Florida, 216 Larsen Hall, 116200, Gainesville, FL 32611-6200
- Nanoscience Institute for Medical and Engineering Technology, The University of Florida, 1041 Center Drive, 116621, Gainesville, FL 32611-6621
| | - Sahba Mobini
- Crayton Pruitt Family Department of Biomedical Engineering, The University of Florida, 1275 Center Dr., BMS Building JG-56, 116131, Gainesville, FL 32611-6131
| | - Matthew D McDermott
- Crayton Pruitt Family Department of Biomedical Engineering, The University of Florida, 1275 Center Dr., BMS Building JG-56, 116131, Gainesville, FL 32611-6131
- Weldon School of Biomedical Engineering, Purdue University, 206 S. Martin Jischke Dr., West Lafayette, IN 47907-2032
| | - James B Graham
- Crayton Pruitt Family Department of Biomedical Engineering, The University of Florida, 1275 Center Dr., BMS Building JG-56, 116131, Gainesville, FL 32611-6131
| | - Kevin J Otto
- Crayton Pruitt Family Department of Biomedical Engineering, The University of Florida, 1275 Center Dr., BMS Building JG-56, 116131, Gainesville, FL 32611-6131
- Nanoscience Institute for Medical and Engineering Technology, The University of Florida, 1041 Center Drive, 116621, Gainesville, FL 32611-6621
- Department of Neuroscience, The University of Florida, 1149 Newell Dr., Room L1-100, 100244, Gainesville, FL 32610-0244
- Department of Neurology, The University of Florida, 2000 SW Archer Rd., Third Floor, 100383, Gainesville, FL 32610
| | - Jack W Judy
- Crayton Pruitt Family Department of Biomedical Engineering, The University of Florida, 1275 Center Dr., BMS Building JG-56, 116131, Gainesville, FL 32611-6131
- Department of Electrical and Computer Engineering, The University of Florida, 216 Larsen Hall, 116200, Gainesville, FL 32611-6200
- Nanoscience Institute for Medical and Engineering Technology, The University of Florida, 1041 Center Drive, 116621, Gainesville, FL 32611-6621
| | - Christine E Schmidt
- Crayton Pruitt Family Department of Biomedical Engineering, The University of Florida, 1275 Center Dr., BMS Building JG-56, 116131, Gainesville, FL 32611-6131
- Nanoscience Institute for Medical and Engineering Technology, The University of Florida, 1041 Center Drive, 116621, Gainesville, FL 32611-6621
| |
Collapse
|
26
|
Bennett C, Samikkannu M, Mohammed F, Dietrich WD, Rajguru SM, Prasad A. Blood brain barrier (BBB)-disruption in intracortical silicon microelectrode implants. Biomaterials 2018; 164:1-10. [PMID: 29477707 DOI: 10.1016/j.biomaterials.2018.02.036] [Citation(s) in RCA: 36] [Impact Index Per Article: 6.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/22/2017] [Revised: 02/15/2018] [Accepted: 02/18/2018] [Indexed: 12/16/2022]
Abstract
Chronically implanted microelectrodes in the neural tissue elicit inflammatory responses that are time varying and have been shown to depend on multiple factors. Among these factors, blood brain barrier (BBB)-disruption has been hypothesized as one of the dominant factors resulting in electrode failure. A series of events that includes BBB and cell-membrane disruption occurs during electrode implantation that triggers multiple biochemical cascades responsible for microglial and astroglial activation, hemorrhage, edema, and release of pro-inflammatory neurotoxic cytokines that causes neuronal degeneration and dysfunction. Typically, microwire arrays and silicon probes are inserted slowly into the neural tissue whereas the silicon Utah MEAs (UMEA) are inserted at a high speed using a pneumatic inserter. In this work, we report the sequelae of electrode-implant induced cortical injury at various acute time points in UMEAs implanted in the brain tissue by quantifying the expression profile for key genes mediating the inflammatory response and tight junction (TJ) and adherens junction (AJ) proteins that form the BBB and are critical to the functioning of the BBB. Our results indicated upregulation of most pro-inflammatory genes relative to naïve controls for all time points. Expression levels for the genes that form the TJ and AJ were downregulated suggestive of BBB-dysfunction. Moreover, there was no significant difference between stab and implant groups suggesting the effects of UMEA insertion-related trauma in the brain tissue. Our results provide an insight into the physiological events related to neuroinflammation and BBB-disruption occurring at acute time-points following insertion of UMEAs.
Collapse
Affiliation(s)
- Cassie Bennett
- Department of Biomedical Engineering, University of Miami, FL, USA
| | | | | | | | - Suhrud M Rajguru
- Department of Biomedical Engineering, University of Miami, FL, USA; Department of Otolaryngology, University of Miami, FL, USA
| | - Abhishek Prasad
- Department of Biomedical Engineering, University of Miami, FL, USA.
| |
Collapse
|
27
|
Suresh AK, Winberry JE, Versteeg C, Chowdhury R, Tomlinson T, Rosenow JM, Miller LE, Bensmaia SJ. Methodological considerations for a chronic neural interface with the cuneate nucleus of macaques. J Neurophysiol 2017; 118:3271-3281. [PMID: 28904101 PMCID: PMC5814711 DOI: 10.1152/jn.00436.2017] [Citation(s) in RCA: 22] [Impact Index Per Article: 3.1] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/13/2017] [Revised: 09/04/2017] [Accepted: 09/05/2017] [Indexed: 12/13/2022] Open
Abstract
While the response properties of neurons in the somatosensory nerves and anterior parietal cortex have been extensively studied, little is known about the encoding of tactile and proprioceptive information in the cuneate nucleus (CN) or external cuneate nucleus (ECN), the first recipients of upper limb somatosensory afferent signals. The major challenge in characterizing neural coding in CN/ECN has been to record from these tiny, difficult-to-access brain stem structures. Most previous investigations of CN response properties have been carried out in decerebrate or anesthetized animals, thereby eliminating the well-documented top-down signals from cortex, which likely exert a strong influence on CN responses. Seeking to fill this gap in our understanding of somatosensory processing, we describe an approach to chronically implanting arrays of electrodes in the upper limb representation in the brain stem in primates. First, we describe the topography of CN/ECN in rhesus macaques, including its somatotopic organization and the layout of its submodalities (touch and proprioception). Second, we describe the design of electrode arrays and the implantation strategy to obtain stable recordings. Third, we show sample responses of CN/ECN neurons in brain stem obtained from awake, behaving monkeys. With this method, we are in a position to characterize, for the first time, somatosensory representations in CN and ECN of primates.NEW & NOTEWORTHY In primates, the neural basis of touch and of our sense of limb posture and movements has been studied in the peripheral nerves and in somatosensory cortex, but coding in the cuneate and external cuneate nuclei, the first processing stage for these signals in the central nervous system, remains an enigma. We have developed a method to record from these nuclei, thereby paving the way to studying how sensory information from the limb is encoded there.
Collapse
Affiliation(s)
- Aneesha K Suresh
- Committee on Computational Neuroscience, University of Chicago, Chicago, Illinois
| | - Jeremy E Winberry
- Department of Organismal Biology and Anatomy, University of Chicago, Chicago, Illinois
| | - Christopher Versteeg
- Department of Biomedical Engineering, McCormick School of Engineering, Northwestern University, Evanston, Illinois
| | - Raeed Chowdhury
- Department of Biomedical Engineering, McCormick School of Engineering, Northwestern University, Evanston, Illinois
| | - Tucker Tomlinson
- Department of Physiology, Feinberg School of Medicine, Northwestern University, Chicago, Illinois
| | - Joshua M Rosenow
- Department of Neurosurgery, Feinberg School of Medicine, Northwestern University, Chicago, Illinois; and
| | - Lee E Miller
- Department of Biomedical Engineering, McCormick School of Engineering, Northwestern University, Evanston, Illinois
- Department of Physiology, Feinberg School of Medicine, Northwestern University, Chicago, Illinois
- Department of Physical Medicine and Rehabilitation, Feinberg School of Medicine, Northwestern University, Chicago, Illinois
| | - Sliman J Bensmaia
- Committee on Computational Neuroscience, University of Chicago, Chicago, Illinois;
- Department of Organismal Biology and Anatomy, University of Chicago, Chicago, Illinois
| |
Collapse
|
28
|
Dotson NM, Hoffman SJ, Goodell B, Gray CM. A Large-Scale Semi-Chronic Microdrive Recording System for Non-Human Primates. Neuron 2017; 96:769-782.e2. [DOI: 10.1016/j.neuron.2017.09.050] [Citation(s) in RCA: 42] [Impact Index Per Article: 6.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/19/2017] [Revised: 08/08/2017] [Accepted: 09/26/2017] [Indexed: 01/20/2023]
|
29
|
Bosking WH, Beauchamp MS, Yoshor D. Electrical Stimulation of Visual Cortex: Relevance for the Development of Visual Cortical Prosthetics. Annu Rev Vis Sci 2017; 3:141-166. [PMID: 28753382 PMCID: PMC6916716 DOI: 10.1146/annurev-vision-111815-114525] [Citation(s) in RCA: 47] [Impact Index Per Article: 6.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/09/2022]
Abstract
Electrical stimulation of the cerebral cortex is a powerful tool for exploring cortical function. Stimulation of early visual cortical areas is easily detected by subjects and produces simple visual percepts known as phosphenes. A device implanted in visual cortex that generates patterns of phosphenes could be used as a substitute for natural vision in blind patients. We review the possibilities and limitations of such a device, termed a visual cortical prosthetic. Currently, we can predict the location and size of phosphenes produced by stimulation of single electrodes. A functional prosthetic, however, must produce spatial temporal patterns of activity that will result in the perception of complex visual objects. Although stimulation of later visual cortical areas alone usually does not lead to a visual percept, it can alter visual perception and the performance of visual behaviors, and training subjects to use signals injected into these areas may be possible.
Collapse
Affiliation(s)
- William H Bosking
- Department of Neurosurgery, Baylor College of Medicine, Houston, Texas 77030; , ,
| | - Michael S Beauchamp
- Department of Neurosurgery, Baylor College of Medicine, Houston, Texas 77030; , ,
| | - Daniel Yoshor
- Department of Neurosurgery, Baylor College of Medicine, Houston, Texas 77030; , ,
| |
Collapse
|
30
|
Oh K, Byun D, Kim S. Polymer-based interconnection cables to integrate with flexible penetrating microelectrode arrays. Biomed Microdevices 2017; 19:76. [PMID: 28842779 DOI: 10.1007/s10544-017-0217-9] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/25/2022]
Abstract
There have been various types of interconnection methods for neural interfacing electrodes, such as silicon ribbon cables, wire bonding and polymer-based cables. In this study, interconnection cables were developed for integration with a Flexible Penetrating Microelectrode Array (FPMA) that was previously developed for neural signal recording or stimulation. Polyimide and parylene C were selected as base materials for the interconnection cables as both materials can preserve the flexibility of the FPMA better than other interconnection methods such as silicon ribbon cable or wire bonding. We conducted durability tests to determine if the interconnection cables were suitable for in-vivo implantation, by long-term soaking of the cables in phosphate buffered saline solution. We measured the changes in impedance over time, and equivalent circuit models were used to analyze the electrochemical phenomena on the surface of the cables. Lastly, we implanted the cable-integrated electrodes device onto rabbit's sciatic nerve and recorded neural signals to prove the feasibility of the developed FPMA integration system.
Collapse
Affiliation(s)
- Keonghwan Oh
- Department of Medical System Engineering, Gwangju Institute of Science and Technology, Gwangju, Republic of Korea
| | - Donghak Byun
- School of Mechatronics, Gwangju Institute of Science and Technology, Gwangju, Republic of Korea
| | - Sohee Kim
- Department of Robotics Engineering, Daegu Gyeongbuk Institute of Science and Technology (DGIST), Daegu, Republic of Korea.
| |
Collapse
|
31
|
Saturation in Phosphene Size with Increasing Current Levels Delivered to Human Visual Cortex. J Neurosci 2017; 37:7188-7197. [PMID: 28652411 DOI: 10.1523/jneurosci.2896-16.2017] [Citation(s) in RCA: 41] [Impact Index Per Article: 5.9] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/14/2016] [Revised: 05/19/2017] [Accepted: 05/25/2017] [Indexed: 11/21/2022] Open
Abstract
Electrically stimulating early visual cortex results in a visual percept known as a phosphene. Although phosphenes can be evoked by a wide range of electrode sizes and current amplitudes, they are invariably described as small. To better understand this observation, we electrically stimulated 93 electrodes implanted in the visual cortex of 13 human subjects who reported phosphene size while stimulation current was varied. Phosphene size increased as the stimulation current was initially raised above threshold, but then rapidly reached saturation. Phosphene size also depended on the location of the stimulated site, with size increasing with distance from the foveal representation. We developed a model relating phosphene size to the amount of activated cortex and its location within the retinotopic map. First, a sigmoidal curve was used to predict the amount of activated cortex at a given current. Second, the amount of active cortex was converted to degrees of visual angle by multiplying by the inverse cortical magnification factor for that retinotopic location. This simple model accurately predicted phosphene size for a broad range of stimulation currents and cortical locations. The unexpected saturation in phosphene sizes suggests that the functional architecture of cerebral cortex may impose fundamental restrictions on the spread of artificially evoked activity and this may be an important consideration in the design of cortical prosthetic devices.SIGNIFICANCE STATEMENT Understanding the neural basis for phosphenes, the visual percepts created by electrical stimulation of visual cortex, is fundamental to the development of a visual cortical prosthetic. Our experiments in human subjects implanted with electrodes over visual cortex show that it is the activity of a large population of cells spread out across several millimeters of tissue that supports the perception of a phosphene. In addition, we describe an important feature of the production of phosphenes by electrical stimulation: phosphene size saturates at a relatively low current level. This finding implies that, with current methods, visual prosthetics will have a limited dynamic range available to control the production of spatial forms and that more advanced stimulation methods may be required.
Collapse
|
32
|
Lebedev MA, Nicolelis MAL. Brain-Machine Interfaces: From Basic Science to Neuroprostheses and Neurorehabilitation. Physiol Rev 2017; 97:767-837. [PMID: 28275048 DOI: 10.1152/physrev.00027.2016] [Citation(s) in RCA: 233] [Impact Index Per Article: 33.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/08/2023] Open
Abstract
Brain-machine interfaces (BMIs) combine methods, approaches, and concepts derived from neurophysiology, computer science, and engineering in an effort to establish real-time bidirectional links between living brains and artificial actuators. Although theoretical propositions and some proof of concept experiments on directly linking the brains with machines date back to the early 1960s, BMI research only took off in earnest at the end of the 1990s, when this approach became intimately linked to new neurophysiological methods for sampling large-scale brain activity. The classic goals of BMIs are 1) to unveil and utilize principles of operation and plastic properties of the distributed and dynamic circuits of the brain and 2) to create new therapies to restore mobility and sensations to severely disabled patients. Over the past decade, a wide range of BMI applications have emerged, which considerably expanded these original goals. BMI studies have shown neural control over the movements of robotic and virtual actuators that enact both upper and lower limb functions. Furthermore, BMIs have also incorporated ways to deliver sensory feedback, generated from external actuators, back to the brain. BMI research has been at the forefront of many neurophysiological discoveries, including the demonstration that, through continuous use, artificial tools can be assimilated by the primate brain's body schema. Work on BMIs has also led to the introduction of novel neurorehabilitation strategies. As a result of these efforts, long-term continuous BMI use has been recently implicated with the induction of partial neurological recovery in spinal cord injury patients.
Collapse
|
33
|
Barz F, Livi A, Lanzilotto M, Maranesi M, Bonini L, Paul O, Ruther P. Versatile, modular 3D microelectrode arrays for neuronal ensemble recordings: from design to fabrication, assembly, and functional validation in non-human primates. J Neural Eng 2017; 14:036010. [DOI: 10.1088/1741-2552/aa5a90] [Citation(s) in RCA: 35] [Impact Index Per Article: 5.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/12/2022]
|
34
|
Spencer KC, Sy JC, Falcón-Banchs R, Cima MJ. A three dimensional in vitro glial scar model to investigate the local strain effects from micromotion around neural implants. LAB ON A CHIP 2017; 17:795-804. [PMID: 28119969 PMCID: PMC5389738 DOI: 10.1039/c6lc01411a] [Citation(s) in RCA: 18] [Impact Index Per Article: 2.6] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/06/2023]
Abstract
Glial scar formation remains a significant barrier to the long term success of neural probes. Micromotion coupled with mechanical mismatch between the probe and tissue is believed to be a key driver of the inflammatory response. In vitro glial scar models present an intermediate step prior to conventional in vivo histology experiments as they enable cell-device interactions to be tested on a shorter timescale, with the ability to conduct broader biochemical assays. No established in vitro models have incorporated methods to assess device performance with respect to mechanical factors. In this study, we describe an in vitro glial scar model that combines high-precision linear actuators to simulate axial micromotion around neural implants with a 3D primary neural cell culture in a collagen gel. Strain field measurements were conducted to visualize the local displacement within the gel in response to micromotion. Primary brain cell cultures were found to be mechanically responsive to micromotion after one week in culture. Astrocytes, as determined by immunohistochemical staining, were found to have significantly increased in cell areas and perimeters in response to micromotion compared to static control wells. These results demonstrate the importance of micromotion when considering the chronic response to neural implants. Going forward, this model provides advantages over existing in vitro models as it will enable critical mechanical design factors of neural implants to be evaluated prior to in vivo testing.
Collapse
Affiliation(s)
- Kevin C Spencer
- Department of Materials Science and Engineering, Massachusetts Institute of Technology, Cambridge, MA 02139, USA.
| | - Jay C Sy
- Koch Institute for Integrative Cancer Research, Massachusetts Institute of Technology, Cambridge, MA 02139, USA and Department of Biomedical Engineering, Rutgers University, Piscataway, NJ, USA
| | - Roberto Falcón-Banchs
- University of California, Berkeley and University of California, San Francisco Graduate Program in Bioengineering, USA
| | - Michael J Cima
- Department of Materials Science and Engineering, Massachusetts Institute of Technology, Cambridge, MA 02139, USA. and Koch Institute for Integrative Cancer Research, Massachusetts Institute of Technology, Cambridge, MA 02139, USA
| |
Collapse
|
35
|
Novel four-sided neural probe fabricated by a thermal lamination process of polymer films. J Neurosci Methods 2017; 278:25-35. [DOI: 10.1016/j.jneumeth.2016.12.017] [Citation(s) in RCA: 15] [Impact Index Per Article: 2.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/12/2016] [Revised: 12/22/2016] [Accepted: 12/23/2016] [Indexed: 02/02/2023]
|
36
|
Rios G, Lubenov E, Chi D, Roukes ML, Siapas AG. Nanofabricated Neural Probes for Dense 3-D Recordings of Brain Activity. NANO LETTERS 2016; 16:6857-6862. [PMID: 27766885 PMCID: PMC5108031 DOI: 10.1021/acs.nanolett.6b02673] [Citation(s) in RCA: 63] [Impact Index Per Article: 7.9] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 06/28/2016] [Revised: 09/17/2016] [Indexed: 05/19/2023]
Abstract
Computations in brain circuits involve the coordinated activation of large populations of neurons distributed across brain areas. However, monitoring neuronal activity in the brain of intact animals with high temporal and spatial resolution has remained a technological challenge. Here we address this challenge by developing dense, three-dimensional (3-D) electrode arrays for electrophysiology. The 3-D arrays constitute the front-end of a modular and configurable system architecture that enables monitoring neuronal activity with unprecedented scale and resolution.
Collapse
Affiliation(s)
- Gustavo Rios
- Division of Biology and Biological
Engineering, Division of Engineering and Applied
Science, Division of Physics, Mathematics, and Astronomy, and Kavli Nanoscience Institute, California Institute of Technology, Pasadena, California 91125, United States
| | - Evgueniy
V. Lubenov
- Division of Biology and Biological
Engineering, Division of Engineering and Applied
Science, Division of Physics, Mathematics, and Astronomy, and Kavli Nanoscience Institute, California Institute of Technology, Pasadena, California 91125, United States
| | - Derrick Chi
- Division of Biology and Biological
Engineering, Division of Engineering and Applied
Science, Division of Physics, Mathematics, and Astronomy, and Kavli Nanoscience Institute, California Institute of Technology, Pasadena, California 91125, United States
| | - Michael L. Roukes
- Division of Biology and Biological
Engineering, Division of Engineering and Applied
Science, Division of Physics, Mathematics, and Astronomy, and Kavli Nanoscience Institute, California Institute of Technology, Pasadena, California 91125, United States
- E-mail:
| | - Athanassios G. Siapas
- Division of Biology and Biological
Engineering, Division of Engineering and Applied
Science, Division of Physics, Mathematics, and Astronomy, and Kavli Nanoscience Institute, California Institute of Technology, Pasadena, California 91125, United States
- E-mail:
| |
Collapse
|
37
|
Chernov MM, Chen G, Torre-Healy LA, Friedman RM, Roe AW. Microelectrode array stimulation combined with intrinsic optical imaging: A novel tool for functional brain mapping. J Neurosci Methods 2016; 263:7-14. [PMID: 26820903 DOI: 10.1016/j.jneumeth.2016.01.018] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/29/2015] [Revised: 12/24/2015] [Accepted: 01/16/2016] [Indexed: 02/03/2023]
Abstract
BACKGROUND Functional brain mapping via cortical microstimulation is a widely used clinical and experimental tool. However, data are traditionally collected point by point, making the technique very time consuming. Moreover, even in skilled hands, consistent penetration depths are difficult to achieve. Finally, the effects of microstimulation are assessed behaviorally, with no attempt to capture the activity of the local cortical circuits being stimulated. NEW METHOD We propose a novel method for functional brain mapping, which combines the use of a microelectrode array with intrinsic optical imaging. The precise spacing of electrodes allows for fast, accurate mapping of the area of interest in a regular grid. At the same time, the optical window allows for visualization of local neural connections when stimulation is combined with intrinsic optical imaging. RESULTS We demonstrate the efficacy of our technique using the primate motor cortex as a sample application, using a combination of microstimulation, imaging and electrophysiological recordings during wakefulness and under anesthesia. Comparison with current method: We find the data collected with our method is consistent with previous data published by others. We believe that our approach enables data to be collected faster and in a more consistent fashion and makes possible a number of studies that would be difficult to carry out with the traditional approach. CONCLUSIONS Our technique allows for simultaneous modulation and imaging of cortical sensorimotor networks in wakeful subjects over multiple sessions which is highly desirable for both the study of cortical organization and the design of brain machine interfaces.
Collapse
Affiliation(s)
- Mykyta M Chernov
- Department of Psychology, Vanderbilt University, 111 21st Ave S, Nashville, TN 37240, United States.
| | - Gang Chen
- Department of Psychology, Vanderbilt University, 111 21st Ave S, Nashville, TN 37240, United States
| | - Luke A Torre-Healy
- Department of Psychology, Vanderbilt University, 111 21st Ave S, Nashville, TN 37240, United States
| | - Robert M Friedman
- Department of Psychology, Vanderbilt University, 111 21st Ave S, Nashville, TN 37240, United States
| | - Anna W Roe
- Department of Psychology, Vanderbilt University, 111 21st Ave S, Nashville, TN 37240, United States
| |
Collapse
|
38
|
Kim S, Callier T, Tabot GA, Gaunt RA, Tenore FV, Bensmaia SJ. Behavioral assessment of sensitivity to intracortical microstimulation of primate somatosensory cortex. Proc Natl Acad Sci U S A 2015; 112:15202-7. [PMID: 26504211 PMCID: PMC4679002 DOI: 10.1073/pnas.1509265112] [Citation(s) in RCA: 80] [Impact Index Per Article: 8.9] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/22/2023] Open
Abstract
Intracortical microstimulation (ICMS) is a powerful tool to investigate the functional role of neural circuits and may provide a means to restore sensation for patients for whom peripheral stimulation is not an option. In a series of psychophysical experiments with nonhuman primates, we investigate how stimulation parameters affect behavioral sensitivity to ICMS. Specifically, we deliver ICMS to primary somatosensory cortex through chronically implanted electrode arrays across a wide range of stimulation regimes. First, we investigate how the detectability of ICMS depends on stimulation parameters, including pulse width, frequency, amplitude, and pulse train duration. Then, we characterize the degree to which ICMS pulse trains that differ in amplitude lead to discriminable percepts across the range of perceptible and safe amplitudes. We also investigate how discriminability of pulse amplitude is modulated by other stimulation parameters-namely, frequency and duration. Perceptual judgments obtained across these various conditions will inform the design of stimulation regimes for neuroscience and neuroengineering applications.
Collapse
Affiliation(s)
- Sungshin Kim
- Department of Organismal Biology and Anatomy, University of Chicago, Chicago, IL 60637
| | - Thierri Callier
- Department of Organismal Biology and Anatomy, University of Chicago, Chicago, IL 60637
| | - Gregg A Tabot
- Committee on Computational Neuroscience, University of Chicago, Chicago, IL 60637
| | - Robert A Gaunt
- Department of Physical Medicine and Rehabilitation, University of Pittsburgh, Pittsburgh, PA 15213
| | - Francesco V Tenore
- Research and Exploratory Development Department, Applied Physics Laboratory, Johns Hopkins University, Laurel, MD 20723
| | - Sliman J Bensmaia
- Department of Organismal Biology and Anatomy, University of Chicago, Chicago, IL 60637; Committee on Computational Neuroscience, University of Chicago, Chicago, IL 60637;
| |
Collapse
|
39
|
Agorelius J, Tsanakalis F, Friberg A, Thorbergsson PT, Pettersson LME, Schouenborg J. An array of highly flexible electrodes with a tailored configuration locked by gelatin during implantation-initial evaluation in cortex cerebri of awake rats. Front Neurosci 2015; 9:331. [PMID: 26441505 PMCID: PMC4585103 DOI: 10.3389/fnins.2015.00331] [Citation(s) in RCA: 49] [Impact Index Per Article: 5.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/05/2015] [Accepted: 09/04/2015] [Indexed: 12/02/2022] Open
Abstract
BACKGROUND A major challenge in the field of neural interfaces is to overcome the problem of poor stability of neuronal recordings, which impedes long-term studies of individual neurons in the brain. Conceivably, unstable recordings reflect relative movements between electrode and tissue. To address this challenge, we have developed a new ultra-flexible electrode array and evaluated its performance in awake non-restrained animals. METHODS An array of eight separated gold leads (4 × 10 μm), individually flexible in 3D, were cut from a gold sheet using laser milling and insulated with Parylene C. To provide structural support during implantation into rat cortex, the electrode array was embedded in a hard gelatin based material, which dissolves after implantation. Recordings were made during 3 weeks. At termination, the animals were perfused with fixative and frozen to prevent dislocation of the implanted electrodes. A thick slice of brain tissue, with the electrode array still in situ, was made transparent using methyl salicylate to evaluate the conformation of the implanted electrode array. RESULTS Median noise levels and signal/noise remained relatively stable during the 3 week observation period; 4.3-5.9 μV and 2.8-4.2, respectively. The spike amplitudes were often quite stable within recording sessions and for 15% of recordings where single-units were identified, the highest-SNR unit had an amplitude higher than 150 μV. In addition, high correlations (>0.96) between unit waveforms recorded at different time points were obtained for 58% of the electrode sites. The structure of the electrode array was well preserved 3 weeks after implantation. CONCLUSIONS A new implantable multichannel neural interface, comprising electrodes individually flexible in 3D that retain its architecture and functionality after implantation has been developed. Since the new neural interface design is adaptable, it offers a versatile tool to explore the function of various brain structures.
Collapse
Affiliation(s)
- Johan Agorelius
- Department of Experimental Medical Science, Neuronano Research Centre, Lund UniversityLund, Sweden
- The Nanometer Structure Consortium, Lund UniversityLund, Sweden
| | - Fotios Tsanakalis
- Department of Experimental Medical Science, Neuronano Research Centre, Lund UniversityLund, Sweden
| | - Annika Friberg
- Department of Experimental Medical Science, Neuronano Research Centre, Lund UniversityLund, Sweden
| | - Palmi T. Thorbergsson
- Department of Experimental Medical Science, Neuronano Research Centre, Lund UniversityLund, Sweden
| | - Lina M. E. Pettersson
- Department of Experimental Medical Science, Neuronano Research Centre, Lund UniversityLund, Sweden
| | - Jens Schouenborg
- Department of Experimental Medical Science, Neuronano Research Centre, Lund UniversityLund, Sweden
- The Nanometer Structure Consortium, Lund UniversityLund, Sweden
| |
Collapse
|
40
|
Kolarcik CL, Luebben SD, Sapp SA, Hanner J, Snyder N, Kozai TDY, Chang E, Nabity JA, Nabity ST, Lagenaur CF, Cui XT. Elastomeric and soft conducting microwires for implantable neural interfaces. SOFT MATTER 2015; 11:4847-61. [PMID: 25993261 PMCID: PMC4466039 DOI: 10.1039/c5sm00174a] [Citation(s) in RCA: 50] [Impact Index Per Article: 5.6] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/05/2023]
Abstract
Current designs for microelectrodes used for interfacing with the nervous system elicit a characteristic inflammatory response that leads to scar tissue encapsulation, electrical insulation of the electrode from the tissue and ultimately failure. Traditionally, relatively stiff materials like tungsten and silicon are employed which have mechanical properties several orders of magnitude different from neural tissue. This mechanical mismatch is thought to be a major cause of chronic inflammation and degeneration around the device. In an effort to minimize the disparity between neural interface devices and the brain, novel soft electrodes consisting of elastomers and intrinsically conducting polymers were fabricated. The physical, mechanical and electrochemical properties of these materials were extensively characterized to identify the formulations with the optimal combination of parameters including Young's modulus, elongation at break, ultimate tensile strength, conductivity, impedance and surface charge injection. Our final electrode has a Young's modulus of 974 kPa which is five orders of magnitude lower than tungsten and significantly lower than other polymer-based neural electrode materials. In vitro cell culture experiments demonstrated the favorable interaction between these soft materials and neurons, astrocytes and microglia, with higher neuronal attachment and a two-fold reduction in inflammatory microglia attachment on soft devices compared to stiff controls. Surface immobilization of neuronal adhesion proteins on these microwires further improved the cellular response. Finally, in vivo electrophysiology demonstrated the functionality of the elastomeric electrodes in recording single unit activity in the rodent visual cortex. The results presented provide initial evidence in support of the use of soft materials in neural interface applications.
Collapse
Affiliation(s)
- Christi L Kolarcik
- Department of Bioengineering, University of Pittsburgh, 5057 Biomedical Science Tower 3, 3501 Fifth Avenue, Pittsburgh, PA, USA.
| | | | | | | | | | | | | | | | | | | | | |
Collapse
|
41
|
Buzsáki G, Stark E, Berényi A, Khodagholy D, Kipke DR, Yoon E, Wise KD. Tools for probing local circuits: high-density silicon probes combined with optogenetics. Neuron 2015; 86:92-105. [PMID: 25856489 PMCID: PMC4392339 DOI: 10.1016/j.neuron.2015.01.028] [Citation(s) in RCA: 167] [Impact Index Per Article: 18.6] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/24/2023]
Abstract
To understand how function arises from the interactions between neurons, it is necessary to use methods that allow the monitoring of brain activity at the single-neuron, single-spike level and the targeted manipulation of the diverse neuron types selectively in a closed-loop manner. Large-scale recordings of neuronal spiking combined with optogenetic perturbation of identified individual neurons has emerged as a suitable method for such tasks in behaving animals. To fully exploit the potential power of these methods, multiple steps of technical innovation are needed. We highlight the current state of the art in electrophysiological recording methods, combined with optogenetics, and discuss directions for progress. In addition, we point to areas where rapid development is in progress and discuss topics where near-term improvements are possible and needed.
Collapse
Affiliation(s)
- György Buzsáki
- The Neuroscience Institute, New York University, School of Medicine, New York, NY 10016, USA; Center for Neural Science, New York University, School of Medicine, New York, NY 10016, USA.
| | - Eran Stark
- The Neuroscience Institute, New York University, School of Medicine, New York, NY 10016, USA
| | - Antal Berényi
- The Neuroscience Institute, New York University, School of Medicine, New York, NY 10016, USA; MTA-SZTE "Lendület" Oscillatory Neural Networks Research Group, University of Szeged, Department of Physiology, Szeged H-6720, Hungary
| | - Dion Khodagholy
- The Neuroscience Institute, New York University, School of Medicine, New York, NY 10016, USA
| | - Daryl R Kipke
- NeuroNexus Technologies, Inc., Ann Arbor, MI 48108, USA
| | - Euisik Yoon
- Center for Wireless Integrated Microsensing and Systems, The University of Michigan, Ann Arbor, MI 48109-2122, USA
| | - Kensall D Wise
- Center for Wireless Integrated Microsensing and Systems, The University of Michigan, Ann Arbor, MI 48109-2122, USA
| |
Collapse
|
42
|
Update in facial nerve paralysis: tissue engineering and new technologies. Curr Opin Otolaryngol Head Neck Surg 2015; 22:291-9. [PMID: 24979369 DOI: 10.1097/moo.0000000000000062] [Citation(s) in RCA: 28] [Impact Index Per Article: 3.1] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/08/2023]
Abstract
PURPOSE OF REVIEW To present the recent advances in the treatment of facial paralysis, emphasizing the emerging technologies. This review will summarize the current state of the art in the management of facial paralysis and discuss the advances in nerve regeneration, facial reanimation, and use of novel biomaterials. This review includes surgical innovations in reinnervation and reanimation as well as progress with bioelectrical interfaces. RECENT FINDINGS The last decade has witnessed major advances in the understanding of nerve injury and approaches for management. Key innovations include strategies to accelerate nerve regeneration, provide tissue-engineered constructs that may replace nonfunctional nerves, approaches to influence axonal guidance, limiting of donor-site morbidity, and optimization of functional outcomes. Approaches to muscle transfer continue to evolve, and new technologies allow for electrical nerve stimulation and use of artificial tissues. SUMMARY The fields of biomedical engineering and facial reanimation increasingly intersect, with innovative surgical approaches complementing a growing array of tissue engineering tools. The goal of treatment remains the predictable restoration of natural facial movement, with acceptable morbidity and long-term stability. Advances in bioelectrical interfaces and nanotechnology hold promise for widening the window for successful treatment intervention and for restoring both lost neural inputs and muscle function.
Collapse
|
43
|
Zhu B, Li W, Lewis RV, Segre CU, Wang R. E-spun composite fibers of collagen and dragline silk protein: fiber mechanics, biocompatibility, and application in stem cell differentiation. Biomacromolecules 2014; 16:202-13. [PMID: 25405355 PMCID: PMC4294589 DOI: 10.1021/bm501403f] [Citation(s) in RCA: 48] [Impact Index Per Article: 4.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/30/2022]
Abstract
![]()
Biocomposite
matrices with high mechanical strength, high stability,
and the ability to direct matrix-specific stem cell differentiation
are essential for the reconstruction of lesioned tissues in tissue
engineering and cell therapeutics. Toward this end, we used the electrospinning
technique to fabricate well-aligned composite fibers from collagen
and spider dragline silk protein, obtained from the milk of transgenic
goats, mimicking the native extracellular matrix (ECM) on a similar
scale. Collagen and the dragline silk proteins were found to mix homogeneously
at all ratios in the electrospun (E-spun) fibers. As a result, the
ultimate tensile strength and elasticity of the fibers increased monotonically
with silk percentage, whereas the stretchability was slightly reduced.
Strikingly, we found that the incorporation of silk proteins to collagen
dramatically increased the matrix stability against excessive fiber
swelling and shape deformation in cell culture medium. When human
decidua parietalis placental stem cells (hdpPSCs) were seeded on the
collagen–silk matrices, the matrices were found to support
cell proliferation at a similar rate as that of the pure collagen
matrix, but they provided cell adhesion with reduced strengths and
induced cell polarization at varied levels. Matrices containing 15
and 30 wt % silk in collagen (CS15, CS30) were found to induce a level
of neural differentiation comparable to that of pure collagen. In
particular, CS15 matrix induced the highest extent of cell polarization
and promoted the development of extended 1D neural filaments strictly
in-line with the aligned fibers. Taking the increased mechanical strength
and fiber stability into consideration, CS15 and CS30 E-spun fibers
offer better alternatives to pure collagen fibers as scaffolds that
can be potentially utilized in neural tissue repair and the development
of future nanobiodevices.
Collapse
Affiliation(s)
- Bofan Zhu
- Department of Biological and Chemical Sciences, ‡Department of Physics, Illinois Institute of Technology , Chicago, Illinois 60616, United States
| | | | | | | | | |
Collapse
|
44
|
|
45
|
Andersen RA, Kellis S, Klaes C, Aflalo T. Toward more versatile and intuitive cortical brain-machine interfaces. Curr Biol 2014; 24:R885-R897. [PMID: 25247368 PMCID: PMC4410026 DOI: 10.1016/j.cub.2014.07.068] [Citation(s) in RCA: 49] [Impact Index Per Article: 4.9] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/18/2023]
Abstract
Brain-machine interfaces have great potential for the development of neuroprosthetic applications to assist patients suffering from brain injury or neurodegenerative disease. One type of brain-machine interface is a cortical motor prosthetic, which is used to assist paralyzed subjects. Motor prosthetics to date have typically used the motor cortex as a source of neural signals for controlling external devices. The review will focus on several new topics in the arena of cortical prosthetics. These include using: recordings from cortical areas outside motor cortex; local field potentials as a source of recorded signals; somatosensory feedback for more dexterous control of robotics; and new decoding methods that work in concert to form an ecology of decode algorithms. These new advances promise to greatly accelerate the applicability and ease of operation of motor prosthetics.
Collapse
Affiliation(s)
- Richard A Andersen
- Division of Biology and Biological Engineering, California Institute of Technology, Mail Code 216-76, Pasadena, CA, 91125-7600, USA.
| | - Spencer Kellis
- Division of Biology and Biological Engineering, California Institute of Technology, Mail Code 216-76, Pasadena, CA, 91125-7600, USA
| | - Christian Klaes
- Division of Biology and Biological Engineering, California Institute of Technology, Mail Code 216-76, Pasadena, CA, 91125-7600, USA
| | - Tyson Aflalo
- Division of Biology and Biological Engineering, California Institute of Technology, Mail Code 216-76, Pasadena, CA, 91125-7600, USA
| |
Collapse
|
46
|
Lee Y, Jun SB. Strategies for minimizing glial response to chronically-implanted microelectrode arrays for neural interface. Biomed Eng Lett 2014. [DOI: 10.1007/s13534-014-0134-2] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/28/2022] Open
|
47
|
Castagnola E, Ansaldo A, Maggiolini E, Ius T, Skrap M, Ricci D, Fadiga L. Smaller, softer, lower-impedance electrodes for human neuroprosthesis: a pragmatic approach. FRONTIERS IN NEUROENGINEERING 2014; 7:8. [PMID: 24795621 PMCID: PMC3997015 DOI: 10.3389/fneng.2014.00008] [Citation(s) in RCA: 39] [Impact Index Per Article: 3.9] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 02/20/2014] [Accepted: 03/29/2014] [Indexed: 12/19/2022]
Abstract
Finding the most appropriate technology for building electrodes to be used for long term implants in humans is a challenging issue. What are the most appropriate technologies? How could one achieve robustness, stability, compatibility, efficacy, and versatility, for both recording and stimulation? There are no easy answers to these questions as even the most fundamental and apparently obvious factors to be taken into account, such as the necessary mechanical, electrical and biological properties, and their interplay, are under debate. We present here our approach along three fundamental parallel pathways: we reduced electrode invasiveness and size without impairing signal-to-noise ratio, we increased electrode active surface area by depositing nanostructured materials, and we protected the brain from direct contact with the electrode without compromising performance. Altogether, these results converge toward high-resolution ECoG arrays that are soft and adaptable to cortical folds, and have been proven to provide high spatial and temporal resolution. This method provides a piece of work which, in our view, makes several steps ahead in bringing such novel devices into clinical settings, opening new avenues in diagnostics of brain diseases, and neuroprosthetic applications.
Collapse
Affiliation(s)
- Elisa Castagnola
- Robotics, Brain and Cognitive Sciences Department, Istituto Italiano di Tecnologia Genoa, Italy
| | - Alberto Ansaldo
- Robotics, Brain and Cognitive Sciences Department, Istituto Italiano di Tecnologia Genoa, Italy
| | - Emma Maggiolini
- Robotics, Brain and Cognitive Sciences Department, Istituto Italiano di Tecnologia Genoa, Italy
| | - Tamara Ius
- Struttura Complessa di Neurochirurgia, Azienda Ospedaliero-Universitaria Santa Maria della Misericordia Udine, Italy
| | - Miran Skrap
- Struttura Complessa di Neurochirurgia, Azienda Ospedaliero-Universitaria Santa Maria della Misericordia Udine, Italy
| | - Davide Ricci
- Robotics, Brain and Cognitive Sciences Department, Istituto Italiano di Tecnologia Genoa, Italy
| | - Luciano Fadiga
- Robotics, Brain and Cognitive Sciences Department, Istituto Italiano di Tecnologia Genoa, Italy ; Section of Human Physiology, Department of Biomedical Sciences, University of Ferrara Ferrara, Italy
| |
Collapse
|
48
|
Prasad A, Xue QS, Dieme R, Sankar V, Mayrand RC, Nishida T, Streit WJ, Sanchez JC. Abiotic-biotic characterization of Pt/Ir microelectrode arrays in chronic implants. FRONTIERS IN NEUROENGINEERING 2014; 7:2. [PMID: 24550823 PMCID: PMC3912984 DOI: 10.3389/fneng.2014.00002] [Citation(s) in RCA: 125] [Impact Index Per Article: 12.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 12/09/2013] [Accepted: 01/14/2014] [Indexed: 11/13/2022]
Abstract
Pt/Ir electrodes have been extensively used in neurophysiology research in recent years as they provide a more inert recording surface as compared to tungsten or stainless steel. While floating microelectrode arrays (FMA) consisting of Pt/Ir electrodes are an option for neuroprosthetic applications, long-term in vivo functional performance characterization of these FMAs is lacking. In this study, we have performed comprehensive abiotic-biotic characterization of Pt/Ir arrays in 12 rats with implant periods ranging from 1 week up to 6 months. Each of the FMAs consisted of 16-channel, 1.5 mm long, and 75 μm diameter microwires with tapered tips that were implanted into the somatosensory cortex. Abiotic characterization included (1) pre-implant and post-explant scanning electron microscopy (SEM) to study recording site changes, insulation delamination and cracking, and (2) chronic in vivo electrode impedance spectroscopy. Biotic characterization included study of microglial responses using a panel of antibodies, such as Iba1, ED1, and anti-ferritin, the latter being indicative of blood-brain barrier (BBB) disruption. Significant structural variation was observed pre-implantation among the arrays in the form of irregular insulation, cracks in insulation/recording surface, and insulation delamination. We observed delamination and cracking of insulation in almost all electrodes post-implantation. These changes altered the electrochemical surface area of the electrodes and resulted in declining impedance over the long-term due to formation of electrical leakage pathways. In general, the decline in impedance corresponded with poor electrode functional performance, which was quantified via electrode yield. Our abiotic results suggest that manufacturing variability and insulation material as an important factor contributing to electrode failure. Biotic results show that electrode performance was not correlated with microglial activation (neuroinflammation) as we were able to observe poor performance in the absence of neuroinflammation, as well as good performance in the presence of neuroinflammation. One biotic change that correlated well with poor electrode performance was intraparenchymal bleeding, which was evident macroscopically in some rats and presented microscopically by intense ferritin immunoreactivity in microglia/macrophages. Thus, we currently consider intraparenchymal bleeding, suboptimal electrode fabrication, and insulation delamination as the major factors contributing toward electrode failure.
Collapse
Affiliation(s)
- Abhishek Prasad
- Department of Biomedical Engineering, University of Miami Coral Gables, FL, USA
| | - Qing-Shan Xue
- Department of Neuroscience, University of Florida Gainesville, FL, USA
| | - Robert Dieme
- Department of Electrical and Computer Engineering, University of Florida Gainesville, FL, USA
| | - Viswanath Sankar
- Department of Electrical and Computer Engineering, University of Florida Gainesville, FL, USA
| | - Roxanne C Mayrand
- Department of Neuroscience, University of Miami Coral Gables, FL, USA
| | - Toshikazu Nishida
- Department of Electrical and Computer Engineering, University of Florida Gainesville, FL, USA
| | - Wolfgang J Streit
- Department of Neuroscience, University of Florida Gainesville, FL, USA
| | - Justin C Sanchez
- Department of Biomedical Engineering, University of Miami Coral Gables, FL, USA ; Department of Neuroscience, University of Miami Coral Gables, FL, USA ; Miami Project to Cure Paralysis, University of Miami Miami, FL, USA
| |
Collapse
|
49
|
Intracellular Neural Recording with Pure Carbon Nanotube Probes. PLoS One 2013; 8:e65715. [PMID: 23840357 PMCID: PMC3686779 DOI: 10.1371/journal.pone.0065715] [Citation(s) in RCA: 44] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/19/2013] [Accepted: 05/01/2013] [Indexed: 11/19/2022] Open
Abstract
The computational complexity of the brain depends in part on a neuron’s capacity to integrate electrochemical information from vast numbers of synaptic inputs. The measurements of synaptic activity that are crucial for mechanistic understanding of brain function are also challenging, because they require intracellular recording methods to detect and resolve millivolt- scale synaptic potentials. Although glass electrodes are widely used for intracellular recordings, novel electrodes with superior mechanical and electrical properties are desirable, because they could extend intracellular recording methods to challenging environments, including long term recordings in freely behaving animals. Carbon nanotubes (CNTs) can theoretically deliver this advance, but the difficulty of assembling CNTs has limited their application to a coating layer or assembly on a planar substrate, resulting in electrodes that are more suitable for in vivo extracellular recording or extracellular recording from isolated cells. Here we show that a novel, yet remarkably simple, millimeter-long electrode with a sub-micron tip, fabricated from self-entangled pure CNTs can be used to obtain intracellular and extracellular recordings from vertebrate neurons in vitro and in vivo. This fabrication technology provides a new method for assembling intracellular electrodes from CNTs, affording a promising opportunity to harness nanotechnology for neuroscience applications.
Collapse
|
50
|
Xie X, Rieth L, Caldwell R, Diwekar M, Tathireddy P, Sharma R, Solzbacher F. Long-term bilayer encapsulation performance of atomic layer deposited Al₂O₃ and Parylene C for biomedical implantable devices. IEEE Trans Biomed Eng 2013; 60:2943-51. [PMID: 23751949 DOI: 10.1109/tbme.2013.2266542] [Citation(s) in RCA: 55] [Impact Index Per Article: 5.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/10/2022]
Abstract
We present an encapsulation scheme that combines atomic layer deposited (ALD) Al₂O₃ and Parylene C for the encapsulation of implantable devices. The encapsulation performances of combining alumina and Parylene C was compared to individual layers of Parylene C or alumina and the bilayer coating had superior encapsulation properties. The alumina-Parylene coated interdigitated electrodes (IDEs) soaked in PBS for up to nine months at temperatures from 37 to 80 °C for accelerated lifetime testing. For 52-nm alumina and 6-μm Parylene C, leakage current was ∼20 pA at 5 VDC, and the impedance was about 3.5 MΩ at 1 kHz with a phase near -87° from electrochemical impedance spectroscopy for samples soaked at 67 °C for equivalent lifetime of 72 months at 37 °C. The change of impedance during the whole soaking period (up to 70 months of equivalent soaking time at 37 °C) over 1 to 10⁶ Hz was within 5%. The stability of impedance indicated almost no degradation of the encapsulation. Bias voltage effect was studied by continuously applying 5 VDC, and it reduced the lifetime of Parylene coating by ∼75% while it showed no measurable effect on the bilayer coating. Lifetime of encapsulation of IDEs with topography generated by attaching a coil and surface mount device (SMD) capacitor was about half of that of planer IDEs. The stable long-term insulation impedance, low leakage current, and better lifetime under bias voltage and topography made this double-layer encapsulation very promising for chronic implantable devices.
Collapse
|