1
|
Meng Y, Liu M, Liao Y, Luo J, Fu X, Sun P. β-cyclodextrin polymers as a new sorbent for solid-phase extraction of xenobiotics in Urine. JOURNAL OF HAZARDOUS MATERIALS 2025; 486:137052. [PMID: 39752833 DOI: 10.1016/j.jhazmat.2024.137052] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 08/26/2024] [Revised: 12/18/2024] [Accepted: 12/30/2024] [Indexed: 03/12/2025]
Abstract
This study systematically assessed the performance of a newly developed solid-phase extraction (SPE) material, cellulose-supported aminated β-cyclodextrin polymer (amine-β-CDP@Cellulose), in determining 44 xenobiotics, encompassing endocrine-disrupting chemicals (EDCs), pharmaceuticals, and food additives in urine samples. The primary objective of the research was to synthesize a new sorbent, optimize the extraction protocol, and elucidate the underlying adsorption and desorption mechanisms. Following optimization, it was observed that amine-β-CDP@Cellulose achieved recoveries ranging from 80 % to 120 % for 28 of the 44 targeted xenobiotics, with only three compounds showing recoveries below 50 %. The superior extraction performance of this novel material can be attributed to the synergistic effects of its structural components: charged functional groups introduced via the cross-linking agent, the hydrophobic cyclodextrin cavity that facilitates inclusion complexation, and abundant hydroxyl groups that enhance adsorption. Additionally, the study included a comparative analysis between amine-β-CDP@Cellulose and commercially available HLB resins. This comparative analysis revealed that the amine-β-CDP@Cellulose method effectively mitigated matrix interferences while maintaining comparable extraction efficiency to the HLB-based method. Collectively, these findings suggest that amine-β-CDP@Cellulose could serve as a sustainable and cost-effective material for extracting xenobiotics from complex matrices.
Collapse
Affiliation(s)
- Yuan Meng
- School of Environmental Science and Engineering, Tianjin University, Tianjin 300072, China
| | - Minqi Liu
- School of Environmental Science and Engineering, Tianjin University, Tianjin 300072, China
| | - Yicheng Liao
- School of Environmental Science and Engineering, Tianjin University, Tianjin 300072, China
| | - Junhuai Luo
- School of Environmental Science and Engineering, Tianjin University, Tianjin 300072, China
| | - Xiaoli Fu
- Institute of Surface-Earth System Science, Tianjin University, Tianjin 300072, China.
| | - Peizhe Sun
- School of Environmental Science and Engineering, Tianjin University, Tianjin 300072, China.
| |
Collapse
|
2
|
Sousa DVM, Pereira FV, Orlando RM. Enhancing Doxorubicin Detection: Multiphase Electroextraction for Efficient and Affordable UHPLC-DAD Analysis in Saliva. Electrophoresis 2024. [PMID: 39607318 DOI: 10.1002/elps.202400094] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/06/2024] [Revised: 10/22/2024] [Accepted: 11/04/2024] [Indexed: 11/29/2024]
Abstract
Attesting optimal drug concentrations in biological fluids is crucial to ensure precise dosage adjustment, to guarantee therapy adherence, and to manage side effects in chemotherapy. Accurate drug determination relies on liquid chromatography and advanced detectors, with sample preparation playing a pivotal role, especially in complex matrices such as biological fluids. This study introduces a multiphase electroextraction (MPEE) of doxorubicin (DOX) in saliva by utilizing a paper point, followed by ultra-high-performance liquid chromatography coupled to diode array detection. The extraction time and electric potential were carried out by using the Doehlert optimization approach, whereas the desorption solvent was fine-tuned through the centroid-simplex experimental design. After optimization, DOX and the internal standard were extracted in 35 min, utilizing an applied voltage of 300 V and a multiwell plate capable of simultaneous extraction of 66 samples. The recovery was 87%-101%, with a linear range between 50 and 500 µg L-1 (R2 > 0.999). The intra- and inter-assay coefficients of variation for precision were <10%, and the limit of detection and limit of quantification were 25 and 50 µg L-¹, respectively. When applied to five different fortified saliva samples, there were no statistically significant differences in the detected concentrations. Although the enrichment factor (0.6) was not as high as expected, the other results confirm that the method obtained is suitable for monitoring DOX in this complex matrix and can contribute to further developments in sample preparation using MPEE approaches.
Collapse
Affiliation(s)
- Denise V M Sousa
- Laboratory of Microfluidics and Separations (LaMS), Department of Chemistry, Federal University of Minas Gerais, Belo Horizonte, Minas Gerais, Brazil
| | - Fabiano V Pereira
- Department of Chemistry, Federal University of Minas Gerais, Belo Horizonte, Minas Gerais, Brazil
| | - Ricardo M Orlando
- Laboratory of Microfluidics and Separations (LaMS), Department of Chemistry, Federal University of Minas Gerais, Belo Horizonte, Minas Gerais, Brazil
| |
Collapse
|
3
|
Abdi K, Ezoddin M, Novasari V, Lamei N. Thermo-Assisted Deep Eutectic Solvent Based on Dispersive Liquid-Liquid Microextraction for Preconcentration of Phthalate Esters in Water Samples and Determination by Gas Chromatography With Flame Ionization Detection. J Sep Sci 2024; 47:e202300878. [PMID: 39304603 DOI: 10.1002/jssc.202300878] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/27/2023] [Revised: 08/25/2024] [Accepted: 08/29/2024] [Indexed: 09/22/2024]
Abstract
A thermo-assisted deep eutectic solvent (DES) based on dispersive liquid-liquid microextraction followed by gas chromatography with flame ionization detection was developed for the analysis of five phthalate esters in different water samples. In the procedure involved, a DES composed of lidocaine, an amphiphilic amine, and oleic acid, was mixed with the sample assisted by ultrasound, and phase separation was achieved with increasing temperature. The heating of the extraction system induced the change of acid-base properties of the DES components. Thus, the formation of microdroplets of DES in the sample was provided, and two phases were separated. The structure of the upper hydrophobic layer was characterized by Fourier-transform infrared spectroscopy. Also, the amount of water in the DES phase was analyzed by mass spectrometer and Karl Fischer titration. Some critical variables on the extraction yield were assessed. The proposed method achieved 1.2-1.3 and 4.1-4.3 µg/L for limits of detection and limits of quantification, respectively. The intra-day and inter-day percentage relative standard deviations (n = 5) were determined to be in the range of 4.2-6.2% and 5.1-7.2%, respectively. Ultimately, this method analyzed the five phthalate esters in different water samples with high recoveries.
Collapse
Affiliation(s)
- Khosrou Abdi
- Department of Radiopharmacy, Faculty of Pharmacy, Tehran University of Medical Sciences, Tehran, Iran
- Iranian National Center for Addiction Studies (INCAS), Tehran University of Medical Sciences, Tehran, Iran
| | - Maryam Ezoddin
- Department of Chemistry, Payame Noor University (PNU), Tehran, Iran
| | - Venous Novasari
- Department of Chemistry, Payame Noor University (PNU), Tehran, Iran
| | - Navid Lamei
- Drug Design and Development Research Center, Tehran University of Medical Sciences, Tehran, Iran
| |
Collapse
|
4
|
Zhao Y, Hao Y, Cui M, Li N, Sun B, Wang Y, Zhao H, Zhang C. An electrochemical biosensor based on DNA tetrahedron nanoprobe for sensitive and selective detection of doxorubicin. Bioelectrochemistry 2024; 157:108652. [PMID: 38271768 DOI: 10.1016/j.bioelechem.2024.108652] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/28/2023] [Revised: 01/16/2024] [Accepted: 01/18/2024] [Indexed: 01/27/2024]
Abstract
Doxorubicin (DOX) is a clinical chemotherapeutic drug and patients usually suffer from dose-dependent cytotoxic and side effects during chemotherapy process with DOX. Therefore, developing a reliable strategy for DOX analysis in biological samples for dosage guidance during chemotherapy process is of great significance. Herein, a sensitive and selective electrochemical biosensor for DOX detection was designed based on gold nanoparticles (AuNPs) and DNA tetrahedron (TDN) nanoprobe bifunctional glassy carbon electrode that could detect DOX in human serum and cell lysate samples. AuNPs not only could enhance electron transfer efficiency and detection sensitivity, but also could improve the biocompatibility of electrode. TDN nanoprobes were employed as specific DOX bind sites that could bind abundant DOX through intercalative characteristics to contribute to sensitive and selective detection. Under the optimal conditions, the proposed TDN nanoprobes-based DOX biosensor exhibited a wide linear range that ranged from 1.0 nM to 50 μM and a low detection limit that was 0.3 nM. Moreover, the proposed DOX biosensor displayed nice selectivity, reproducibility and stability, and was successfully applied for DOX detection in human serum and cell lysate samples. These promising results maybe pave a way for DOX dosage guidance and therapeutic efficacy optimization in clinic.
Collapse
Affiliation(s)
- Yunzhi Zhao
- Hebei Provincial Key Laboratory of Photoelectric Control on Surface and Interface, School of Sciences, Hebei University of Science and Technology, Shijiazhuang 050018, China
| | - Ying Hao
- School of Mathematics and Physics, Handan University, Handan 056005, China
| | - Min Cui
- Hebei Provincial Key Laboratory of Photoelectric Control on Surface and Interface, School of Sciences, Hebei University of Science and Technology, Shijiazhuang 050018, China
| | - Na Li
- Hebei Provincial Key Laboratory of Photoelectric Control on Surface and Interface, School of Sciences, Hebei University of Science and Technology, Shijiazhuang 050018, China
| | - Bao Sun
- Hebei Provincial Key Laboratory of Photoelectric Control on Surface and Interface, School of Sciences, Hebei University of Science and Technology, Shijiazhuang 050018, China
| | - Yu Wang
- College of Chemical Engineering, Shijiazhuang University, Shijiazhuang 050035, China
| | - Haiyan Zhao
- Hebei Provincial Key Laboratory of Photoelectric Control on Surface and Interface, School of Sciences, Hebei University of Science and Technology, Shijiazhuang 050018, China.
| | - Cong Zhang
- Hebei Provincial Key Laboratory of Photoelectric Control on Surface and Interface, School of Sciences, Hebei University of Science and Technology, Shijiazhuang 050018, China.
| |
Collapse
|
5
|
Drimaropoulou G, Christophoridis C, Zacharis CK, Fytianos K. Chemometric Optimization of SPE for the Determination of Multiclass Pesticides in Portable Water Samples by UHPLC-MS/MS. BULLETIN OF ENVIRONMENTAL CONTAMINATION AND TOXICOLOGY 2024; 112:48. [PMID: 38459992 PMCID: PMC10924705 DOI: 10.1007/s00128-024-03873-2] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 09/25/2023] [Accepted: 02/26/2024] [Indexed: 03/11/2024]
Abstract
This study aimed on the development of a SPE-UHPLC-MS/MS method for the simultaneous determination of pesticide residues in drinking water samples. A chemometric approach was applied to optimize the efficiency of the SPE pretreatment procedure. This study involved (i) the application of a Full Factorial Design for the screening of the significant factors, (ii) the application of a Central Composite Design for the determination of the optimal conditions and (iii) the evaluation and validation of the significance of the statistically proposed models. Oasis HLB cartridges were used for the extraction. The optimum sample volume was 300 mL and the elution solvent 3 mL of the mixture of methanol:ethylacetate 70:30 v/v. The method was validated according to the international guidelines. Recoveries were ranged from 63 to 116% and the detection limits were between 0.1 and 1.5 pg mL- 1. The validated method could be used in routine analysis for pesticides screening.
Collapse
Affiliation(s)
- Garyfallia Drimaropoulou
- Environmental Pollution Control Laboratory, Chemistry Department, Aristotle University of Thessaloniki, Thessaloniki, 54124, Greece
| | - Christophoros Christophoridis
- Environmental Pollution Control Laboratory, Chemistry Department, Aristotle University of Thessaloniki, Thessaloniki, 54124, Greece
| | - Constantinos K Zacharis
- Laboratory of Pharmaceutical Analysis, Department of Pharmacy, Aristotle University of Thessaloniki, Thessaloniki, 54124, Greece
| | - Konstantinos Fytianos
- Environmental Pollution Control Laboratory, Chemistry Department, Aristotle University of Thessaloniki, Thessaloniki, 54124, Greece.
| |
Collapse
|
6
|
Khoshkhan Z, Mirzaei M, Amiri A, Lotfian N, Mague JT. Anticancer Drug Extraction from Plasma Samples Using Three-Dimensional Polyoxometalate-Based Supramolecular Frameworks as Sorbents. Inorg Chem 2024; 63:2877-2887. [PMID: 38284548 DOI: 10.1021/acs.inorgchem.3c02130] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/30/2024]
Abstract
Four self-assembled inorganic-organic hybrid materials, namely, H{Na(H2O)3[Gd(PDA)(H2O)2]3[BW12O40]}·4H2O (1), H{Na(H2O)3[Tb(PDA)(H2O)2]3[BW12O40]}·3H2O (2), H{Na(H2O)3[Er(PDA)(H2O)3]3[BW12O40]}·H2O (3) (PDA = 1,10-phenanthroline-2,9-dicarboxylate), and [Pr3(H2O)13(pydc-OH)2][BW12O40]·12H2O (4) (pydc-OH = 4-hydroxy-2,6-pyridinedicarboxylate), were hydrothermally synthesized and structurally characterized. Hybrids 1-3 are isostructural and contain a Keggin unit, which is linked to lanthanoids to produce distinct trinuclear lanthanoid building blocks. The fragments are connected by anion-π and hydrogen bonding interactions to create 3D networks. In hybrid 4, a trimeric Pr-organic species bearing a Keggin unit forms a 2D coordination polymer, and then hydrogen bonding interactions between 2D layers lead to the formation of a 3D structure. These polyoxometalate-based frameworks were used as sorbents for the dispersive microsolid-phase extraction (D-μSPE) of two anticancer drugs (doxorubicin and epirubicin) in human plasma samples. Analytes were quantified and separated using high-performance liquid chromatography with fluorescence detection (HPLC-FLD). The method's linearity was between 0.8-500 ng mL-1 and 1.0-500 ng mL-1 for the antineoplastic drugs doxorubicin and epirubicin, respectively. The limits of detection (S/N = 3) were in the range of 0.2-0.3 ng mL-1, while the precision was in the range of 3.5-4.3%. Finally, human plasma samples from patients treated with doxorubicin or epirubicin were analyzed by using the D-μSPE-HPLC-FLD method.
Collapse
Affiliation(s)
- Zakiyeh Khoshkhan
- Department of Chemistry, Faculty of Science, Ferdowsi University of Mashhad, 9177948974 Mashhad, Iran
| | - Masoud Mirzaei
- Department of Chemistry, Faculty of Science, Ferdowsi University of Mashhad, 9177948974 Mashhad, Iran
| | - Amirhassan Amiri
- Department of Chemistry, Faculty of Science, Ferdowsi University of Mashhad, 9177948974 Mashhad, Iran
| | - Nahid Lotfian
- Department of Chemistry, Faculty of Science, Ferdowsi University of Mashhad, 9177948974 Mashhad, Iran
| | - Joel T Mague
- Department of Chemistry, Tulane University, New Orleans, Louisiana 70118, United States
| |
Collapse
|
7
|
Mo J, Wang S, Zeng J, Ding X. Aptamer-based Upconversion Fluorescence Sensor for Doxorubicin Detection. J Fluoresc 2023; 33:1897-1905. [PMID: 36877414 DOI: 10.1007/s10895-023-03184-5] [Citation(s) in RCA: 5] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/18/2023] [Accepted: 02/14/2023] [Indexed: 03/07/2023]
Abstract
Doxorubicin is a common chemotherapeutic drug used to treat a variety of cancers. Monitoring the concentration of doxorubicin in human biological fluids is vital for treatment. In this work, we report an aptamer-functionalized, 808 nm-excited core-shell upconversion fluorescence sensor for specific detection of doxorubicin (DOX). Upconversion nanoparticles and DOX are used as energy donors and energy acceptors respectively. Aptamers immobilized on the surface of upconversion nanoparticles act as the molecular recognition element for DOX. The binding of DOX to the immobilized aptamers results in the fluorescence quenching of the upconversion nanoparticles via a fluorescence resonance energy transfer process. The relative fluorescence intensity exhibits a good linear response to DOX concentration in the range of 0.5 μM to 55 μM with a detection limit of 0.5 μM. The aptasensor displays high specificity and anti-interference against other antibiotics, common ions, and biomolecules owing to strong and specific interactions of aptamers towards DOX. The sensor is further applied for the detection of DOX in urine with spike recoveries of nearly 100%.
Collapse
Affiliation(s)
- Jingwen Mo
- Jiangsu Key Laboratory for Design & Manufacture of Micro/Nano Biomedical Instruments, Engineering Research Center of New Light Sources Technology & Equipment-Ministry of Education, and School of Mechanical Engineering, Southeast University, Nanjing, 210096, People's Republic of China.
| | - Shichang Wang
- Jiangsu Key Laboratory for Design & Manufacture of Micro/Nano Biomedical Instruments, Engineering Research Center of New Light Sources Technology & Equipment-Ministry of Education, and School of Mechanical Engineering, Southeast University, Nanjing, 210096, People's Republic of China
| | - Jiaying Zeng
- School of Public Health, Southeast University, Nanjing, 210009, People's Republic of China.
| | - Xiong Ding
- School of Public Health, Southeast University, Nanjing, 210009, People's Republic of China
| |
Collapse
|
8
|
Hamad AA. The first facile optical density-dependent approach for the analysis of doxorubicin, an oncogenic agent accompanied with the co-prescribed drug; paclitaxel. BMC Chem 2023; 17:59. [PMID: 37328912 DOI: 10.1186/s13065-023-00976-5] [Citation(s) in RCA: 2] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/23/2022] [Accepted: 05/30/2023] [Indexed: 06/18/2023] Open
Abstract
Doxorubicin (DRB) is an anthracycline oncogenic drug extracted from cultures of Streptomyces peucetius var. caesius. It is frequently recommended as an anti-neoplastic agent for the treatment of diverse malignancies. It exerts its antineoplastic effect either via inhibiting the enzyme topoisomerase II and/or via intercalation to DNA or reactive oxygen species generation. In the present article, the direct, simple, one-pot, somewhat eco-safe, and non-extractive spectrophotometric system was executed to track doxorubicin, a chemotherapeutic remedy, in the presence of paclitaxel, a naturally occurring Taxan antineoplastic radical, through the greenness rated method. DRB's optical density was studied in various mediums and solvents to develop the current approach. An acidic ethanolic solution was found to increase the optical density of the sample significantly. At 480 nm., the most remarkable optical density was obtained. Various experimental factors, including intrinsic media, solvent, pH, and stability time, were investigated and controlled. The current approach achieved linearity within the 0.6-40.0 µg mL-1 range, accompanied by a limit of both detection and quantification (LOD and LOQ) of 0.18 and 0.55 µg mL-1, correspondingly. The approach was validated under the ICH guidelines (Quality Guidelines). The system's greenness and enhancement degree were estimated.
Collapse
Affiliation(s)
- Ahmed Abdulhafez Hamad
- Department of Pharmaceutical Analytical Chemistry, Faculty of Pharmacy, Al-Azhar University, Assiut Branch, Assiut, 71524, Egypt.
| |
Collapse
|
9
|
Kulikova T, Shiabiev I, Padnya P, Rogov A, Evtugyn G, Stoikov I, Porfireva A. Impedimetric DNA Sensor Based on Electropolymerized N-Phenylaminophenothiazine and Thiacalix[4]arene Tetraacids for Doxorubicin Determination. BIOSENSORS 2023; 13:bios13050513. [PMID: 37232875 DOI: 10.3390/bios13050513] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 04/03/2023] [Revised: 04/24/2023] [Accepted: 04/26/2023] [Indexed: 05/27/2023]
Abstract
Electrochemical DNA sensors are highly demanded for fast and reliable determination of antitumor drugs and chemotherapy monitoring. In this work, an impedimetric DNA sensor has been developed on the base of a phenylamino derivative of phenothiazine (PhTz). A glassy carbon electrode was covered with electrodeposited product of PhTz oxidation obtained through multiple scans of the potential. The addition of thiacalix[4]arene derivatives bearing four terminal carboxylic groups in the substituents of the lower rim improved the conditions of electropolymerization and affected the performance of the electrochemical sensor depending on the configuration of the macrocyclic core and molar ratio with PhTz molecules in the reaction medium. Following that, the deposition of DNA by physical adsorption was confirmed by atomic force microscopy and electrochemical impedance spectroscopy. The redox properties of the surface layer obtained changed the electron transfer resistance in the presence of doxorubicin due to its intercalating DNA helix and influencing charge distribution on the electrode interface. This made it possible to determine 3 pM-1 nM doxorubicin in 20 min incubation (limit of detection 1.0 pM). The DNA sensor developed was tested on a bovine serum protein solution, Ringer-Locke's solution mimicking plasma electrolytes and commercial medication (doxorubicin-LANS) and showed a satisfactory recovery rate of 90-105%. The sensor could find applications in pharmacy and medical diagnostics for the assessment of drugs able to specifically bind to DNA.
Collapse
Affiliation(s)
- Tatjana Kulikova
- A.M. Butlerov' Chemistry Institute of Kazan Federal University, 18 Kremlevskaya Street, 420008 Kazan, Russia
| | - Igor Shiabiev
- A.M. Butlerov' Chemistry Institute of Kazan Federal University, 18 Kremlevskaya Street, 420008 Kazan, Russia
| | - Pavel Padnya
- A.M. Butlerov' Chemistry Institute of Kazan Federal University, 18 Kremlevskaya Street, 420008 Kazan, Russia
| | - Alexey Rogov
- Interdisciplinary Center of Analytical Microscopy of Kazan Federal University, 18 Kremlevskaya Street, 420008 Kazan, Russia
| | - Gennady Evtugyn
- A.M. Butlerov' Chemistry Institute of Kazan Federal University, 18 Kremlevskaya Street, 420008 Kazan, Russia
- Analytical Chemistry Department, Chemical Technology Institute, Ural Federal University, 19 Mira Street, 620002 Ekaterinburg, Russia
| | - Ivan Stoikov
- A.M. Butlerov' Chemistry Institute of Kazan Federal University, 18 Kremlevskaya Street, 420008 Kazan, Russia
| | - Anna Porfireva
- A.M. Butlerov' Chemistry Institute of Kazan Federal University, 18 Kremlevskaya Street, 420008 Kazan, Russia
| |
Collapse
|
10
|
Antoniou G, Alampanos V, Kabir A, Zughaibi T, Furton KG, Samanidou V. Magnet Integrated Fabric Phase Sorptive Extraction for the Extraction of Resin Monomers from Human Urine Prior to HPLC Analysis. SEPARATIONS 2023. [DOI: 10.3390/separations10040235] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 04/05/2023] Open
Abstract
In this work, a method for the simultaneous determination of four resin monomers: Bisphenol A, bisphenol A methacrylate glycidate, triethyleneglycol-dimethacrylate, and urethane dimethacrylate, from human urine using magnet integrated fabric phase sorptive extraction (MI-FPSE), followed by high performance liquid chromatography (HPLC) diode array detection (HPLC-DAD), is presented. MI-FPSE is a novel configuration of FPSE that incorporates the stirring and extraction mechanism into one device, resulting in an improved extraction kinetic factor. FPSE is a green sample preparation technique that uses a flexible surface, such as cellulose, coated with a polymeric material using sol–gel technology. Poly(tetrahydrofuran) (PTHF) material was selected, due to its higher efficiency in terms of recovery rate among the studied MI-FPSE membranes. Optimization of the extraction process was performed based on several extraction and elution parameters. The method was validated for its linearity, selectivity, accuracy, precision, and stability of the samples. For the four compounds, the LOD and LOQ were 0.170 ng/μL and 0.050 ng/μL, respectively. The relative standard deviation of the method was less than 9.8% and 11.9%, for the within-day and between-day precision, respectively. The relative recoveries were between 85.6 and 105.2% in all cases, showing a good accuracy. The effectiveness of the proposed method was confirmed through successful application to the bioanalysis of real urine samples.
Collapse
Affiliation(s)
- Georgios Antoniou
- Laboratory of Analytical Chemistry, Department of Chemistry, Aristotle University of Thessaloniki, 54124 Thessaloniki, Greece
| | - Vasileios Alampanos
- Laboratory of Analytical Chemistry, Department of Chemistry, Aristotle University of Thessaloniki, 54124 Thessaloniki, Greece
| | - Abuzar Kabir
- International Forensic Research Institute, Department of Chemistry and Biochemistry, Florida International University, Miami, FL 33199, USA
| | - Torki Zughaibi
- Department of Medical Laboratory Sciences, Faculty of Applied Medical Sciences, King Abdulaziz University, Jeddah 21589, Saudi Arabia
- King Fahd Medical Research Center, King Abdulaziz University, Jeddah 21589, Saudi Arabia
| | - Kenneth G. Furton
- International Forensic Research Institute, Department of Chemistry and Biochemistry, Florida International University, Miami, FL 33199, USA
| | - Victoria Samanidou
- Laboratory of Analytical Chemistry, Department of Chemistry, Aristotle University of Thessaloniki, 54124 Thessaloniki, Greece
| |
Collapse
|
11
|
Sousa DVM, Pereira FV, Boratto VHM, Orlando RM. Multiphase electroextraction as a simple and fast sample preparation alternative for the digital image determination of doxorubicin in saliva. Talanta 2023; 255:124242. [PMID: 36638654 DOI: 10.1016/j.talanta.2022.124242] [Citation(s) in RCA: 5] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/02/2022] [Revised: 12/27/2022] [Accepted: 12/29/2022] [Indexed: 01/01/2023]
Abstract
Monitoring chemotherapeutic drugs in biological fluids is, in many cases, extremely important for dose adjustment, the maintenance of therapies, and the control of side effects. In this work, a method for determining the doxorubicin in saliva by digital image analysis (DIA) was optimised and validated. Images from a paper point were obtained using a conventional and cheap flatbed scanner at a 600 ppp resolution. The RGB data channels were obtained from the images in a region of 15 × 15 pixels around the sorbent vertex. The paper point was used as sorbent material in sample preparation using a multiphase electroextraction system. Following optimisation using a Doehlert experimental design, the method was able to simultaneously extract 66 samples in 20 min. The high selectivity of the electric field associated with the sorption capacity of the cellulosic material allowed the chemotherapy drug to be pre-concentrated and quantified in a range between 50 and 500 μg L-1 (R2 > 0.98). The method also exhibited adequate parameters (limits of detection and quantification, recovery, and precision) indicating its potential application in the monitoring of doxorubicin and similar drugs in saliva.
Collapse
|
12
|
Mohammadi SZ, Mousazadeh F, Tajik S. Simultaneous Determination of Doxorubicin and Dasatinib by using Screen-Printed Electrode/Ni–Fe Layered Double Hydroxide. Ind Eng Chem Res 2023. [DOI: 10.1021/acs.iecr.2c03105] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/04/2023]
Affiliation(s)
- Sayed Zia Mohammadi
- Department of Chemistry, Payame Noor University, P.O. Box 19395-3697, Tehran 00000, Iran
| | - Farideh Mousazadeh
- Department of Chemistry, Payame Noor University, P.O. Box 19395-3697, Tehran 00000, Iran
| | - Somayeh Tajik
- Research Center of Tropical and Infectious Diseases, Kerman University of Medical Sciences, P.O. Box 76169-13555, Kerman 00000, Iran
| |
Collapse
|
13
|
A deep eutectic solvent-based microextraction procedure for simple and fast extraction of doxorubicin as an anticancer drug from urine samples followed by 96-well microplates-based spectrophotometric detection. JOURNAL OF THE IRANIAN CHEMICAL SOCIETY 2022. [DOI: 10.1007/s13738-022-02709-2] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 12/23/2022]
|
14
|
Zhao H, Shi K, Zhang C, Ren J, Cui M, Li N, Ji X, Wang R. Spherical COFs decorated with gold nanoparticles and multiwalled carbon nanotubes as signal amplifier for sensitive electrochemical detection of doxorubicin. Microchem J 2022. [DOI: 10.1016/j.microc.2022.107865] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/31/2022]
|
15
|
Designing an "all-in-one" microextraction capsule device for the liquid chromatographic-fluorescence determination of doxorubicin and its metabolites in rat plasma. J Chromatogr A 2022; 1680:463432. [PMID: 36041251 DOI: 10.1016/j.chroma.2022.463432] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/26/2022] [Revised: 08/15/2022] [Accepted: 08/17/2022] [Indexed: 11/24/2022]
Abstract
In this study, an "all-in-one" microextraction device was designed and fabricated for the extraction of doxorubicin and its two metabolites from rat plasma prior to their determination by high performance liquid chromatography coupled to fluorescence detector. A sol-gel-based sorbent was synthesized in situ and incorporated within two conjoined porous polypropylene tubes together with a cylindrical magnetic bar in order to avoid the need of an external stirring bar. Among other sorbents investigated, the moderately polar sol-gel poly(tetrahydrofuran) was found to be advantageous due to its high affinity toward the target analytes. Systematic investigation of the critical parameters affecting the adsorption and the desorption step was carried out. Due to the "built-in" filtration mechanism of the porous microextraction capsules, the isolation of the analytes was performed directly in the plasma matrix without any previous sample pretreatment (i.e., protein precipitation, centrifugation, etc.). The proposed method was validated in terms of linearity, accuracy, precision, specificity, sensitivity, and stability according to the FDA guidelines. The limits of detection ranged between 1 - 2 ng mL-1 while the lower limits of quantitation of the analytes were calculated as 10 ng mL-1. The accuracy (% relative error) was found within -9.7 - 15.3% under both intra- and inter-day conditions. The precision was better than 13.4% in all cases. ComplexGAPI index was employed to present the green attributes of the developed protocol from the preparation of the microextraction device to the final determination of the analytes. Finally, the applicability of the fabricated stand-alone extraction device was demonstrated in the analysis of the target analytes in rat plasma after intravenous administration of doxorubicin in order to assess its pharmacokinetic profile.
Collapse
|
16
|
Alimoradi V, Reza Afshar Mogaddam M, Ali Farajzadeh M, Nemati M, Lotfipour F. Surfactant-assisted salting-out homogenous liquid-liquid extraction based on deep eutectic solvents using central composite design; Application in the extraction of natamycin from fruit juices before its determination by HPLC-UV. Microchem J 2022. [DOI: 10.1016/j.microc.2022.107504] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/18/2022]
|
17
|
Omotola EO, Oluwole AO, Oladoye PO, Olatunji OS. Occurrence, detection and ecotoxicity studies of selected pharmaceuticals in aqueous ecosystems- a systematic appraisal. ENVIRONMENTAL TOXICOLOGY AND PHARMACOLOGY 2022; 91:103831. [PMID: 35151848 DOI: 10.1016/j.etap.2022.103831] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 11/06/2021] [Revised: 01/31/2022] [Accepted: 02/07/2022] [Indexed: 06/14/2023]
Abstract
Pharmaceutical compounds (PCs) have globally emerged as a significant group of environmental contaminants due to the constant detection of their residues in the environment. The main scope of this review is to fill the void of information on the knowledge on the African occurrence of selected PCs in environmental matrices in comparison with those outside Africa and their respective toxic actions on both aquatic and non-aquatic biota through ecotoxicity bioassays. To achieve this objective, the study focused on commonly used and detected pharmaceutical drugs (residues). Based on the conducted literature survey, Africa has the highest levels of ciprofloxacin, sulfamethoxazole, lamivudine, acetaminophen, and diclofenac while Europe has the lowest of all these PC residues in her physical environments. For ecotoxicity bioassays, the few data available are mostly on individual groups of pharmaceuticals whereas there is sparsely available data on their combined forms.
Collapse
Affiliation(s)
- Elizabeth Oyinkansola Omotola
- School of Chemistry and Physics, University of KwaZulu-Natal, Durban 4000, South Africa; Department of Chemical Sciences, Tai Solarin University of Education, Ijebu Ode PMB 2118, Ogun State, Nigeria.
| | | | - Peter Olusakin Oladoye
- Department of Chemistry and Biochemistry, Florida International University, 11200 SW 8th St, Miami, FL 33199, United States
| | | |
Collapse
|
18
|
Manousi N, Vlachaki A, Kika FS, Markopoulou CK, Tzanavaras PD, Zacharis CK. Salting-out homogeneous liquid-liquid microextraction for the determination of azole drugs in human urine: Validation using total error concept. J Sep Sci 2022; 45:1240-1251. [PMID: 35000279 DOI: 10.1002/jssc.202100942] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/29/2021] [Revised: 12/29/2021] [Accepted: 01/05/2022] [Indexed: 12/12/2022]
Abstract
A salting-out homogeneous liquid-liquid microextraction was proposed for the quantification of four azole drugs in human urine prior to high-performance liquid chromatography analysis. The procedure involved the mixing of the sample with acetonitrile in appropriate volumes followed by the addition of sodium sulfate solution in order to facilitate phase separation. The parameters influencing the extraction performance were studied and optimized using a two-step experimental design. The analytical procedure was thoroughly validated using the accuracy profiles as a graphical decision-making tool. The β-expectation tolerance intervals did not exceed the acceptance criteria of ±15% meaning that 95% of future results will be included in the defined bias limits. The limits of detection of the procedure were satisfactory, ranging between 0.01 and 0.03 μg/mL. The mean analytical bias in the spiking levels was satisfactory and ranged between -10.3 and 4.2% while the relative standard deviation was lower than 5.6%. Monte-Carlo simulations followed by capability analysis were employed to investigate the ruggedness of the sample preparation protocol. The developed method offers advantages compared to previously reported approaches for the same type of analysis including extraction efficiency and scaling down of the sample volume and extraction time.
Collapse
Affiliation(s)
- Natalia Manousi
- Laboratory of Analytical Chemistry, Department of Chemistry, Faculty of Sciences, Aristotle University of Thessaloniki, Thessaloniki, Greece
| | - Adamantia Vlachaki
- Laboratory of Pharmaceutical Analysis, Department of Pharmaceutical Technology, School of Pharmacy, Aristotle University of Thessaloniki, Thessaloniki, Greece
| | - Fotini S Kika
- Department of Hematology, Bone Marrow Transplantation Unit, George Papanikolaou General Hospital, Thessaloniki, Greece
| | - Catherine K Markopoulou
- Laboratory of Pharmaceutical Analysis, Department of Pharmaceutical Technology, School of Pharmacy, Aristotle University of Thessaloniki, Thessaloniki, Greece
| | - Paraskevas D Tzanavaras
- Laboratory of Analytical Chemistry, Department of Chemistry, Faculty of Sciences, Aristotle University of Thessaloniki, Thessaloniki, Greece
| | - Constantinos K Zacharis
- Laboratory of Pharmaceutical Analysis, Department of Pharmaceutical Technology, School of Pharmacy, Aristotle University of Thessaloniki, Thessaloniki, Greece
| |
Collapse
|
19
|
Tsanaktsidou E, Markopoulou CK, Tzanavaras PD, Zacharis CK. Homogeneous liquid phase microextraction using hydrophilic media for the determination of fluoroquinolones in human urine using HPLC-FLD. Microchem J 2022. [DOI: 10.1016/j.microc.2021.106906] [Citation(s) in RCA: 7] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/20/2023]
|
20
|
Luiz MT, Dutra JAP, Di Filippo LD, Junior AGT, Tofani LB, Marchetti JM, Chorilli M. Epirubicin: Biological Properties, Analytical Methods, and Drug Delivery Nanosystems. Crit Rev Anal Chem 2021; 53:1080-1093. [PMID: 34818953 DOI: 10.1080/10408347.2021.2007469] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 07/21/2023]
Abstract
Epirubicin (EPI) is a chemotherapeutic agent belonging to the anthracycline drug class indicated for treating several tumors. It acts by suppressing the DNA and RNA synthesis by intercalating between their base pair. However, several side effects are associated with this therapy, including cardiotoxicity and myelosuppression. Therefore, EPI delivery in nanosystems has been an interesting strategy to overcome these limitations and improve the safety and efficacy of EPI. Thus, analytical methods have been used to understand and characterize these nanosystems, including spectrophotometric, spectrofluorimetric, and chromatography. Spectrophotometric and spectrofluorimetric methods have been used to quantify EPI in less complex matrices due to their efficiency, low cost, and green chemistry character. By contrast, high-performance liquid chromatography is a suitable method for detecting EPI in more complex matrices (e.g., plasm and urine) owing to its high sensitivity. This review summarizes physicochemical and pharmacokinetic properties of EPI, its application in drug delivery nanosystems, and the analytical methods employed in its quantification in different matrices, including blood, plasm, urine, and drug delivery nanosystems.
Collapse
Affiliation(s)
- Marcela Tavares Luiz
- School of Pharmaceutical Science of Ribeirao Preto, University of São Paulo (USP), Ribeirao Preto, São Paulo, Brazil
| | | | | | | | - Larissa Bueno Tofani
- School of Pharmaceutical Science of Ribeirao Preto, University of São Paulo (USP), Ribeirao Preto, São Paulo, Brazil
| | - Juliana Maldonado Marchetti
- School of Pharmaceutical Science of Ribeirao Preto, University of São Paulo (USP), Ribeirao Preto, São Paulo, Brazil
| | - Marlus Chorilli
- School of Pharmaceutical Science of São Paulo State University (UNESP), Araraquara, São Paulo, Brazil
| |
Collapse
|
21
|
Hammad SF, Abdallah IA, Bedair A, Mansour FR. Homogeneous liquid-liquid extraction as an alternative sample preparation technique for biomedical analysis. J Sep Sci 2021; 45:185-209. [PMID: 34472701 DOI: 10.1002/jssc.202100452] [Citation(s) in RCA: 31] [Impact Index Per Article: 7.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/07/2021] [Revised: 08/26/2021] [Accepted: 08/27/2021] [Indexed: 12/12/2022]
Abstract
Liquid-liquid extraction is a widely used technique of sample preparation in biomedical analysis. In spite of the high pre-concentration capacities of liquid-liquid extraction, it suffers from a number of limitations including time and effort consumption, large organic solvent utilization, and poor performance in highly polar analytes. Homogeneous liquid-liquid extraction is an alternative sample preparation technique that overcomes some drawbacks of conventional liquid-liquid extraction, and allows employing greener organic solvents in sample treatment. In homogeneous liquid-liquid extraction, a homogeneous phase is formed between the aqueous sample and the water-miscible extractant, followed by chemically or physically induced phase separation. To form the homogeneous phase, aqueous samples are mixed with water-miscible organic solvents, water-immiscible solvents/cosolvents, surfactants, or smart polymers. Then, phase separation is induced chemically (adding salt, sugar, or buffer) or physically (changing temperature or pH). This mode is rapid, sustainable, and cost-effective in comparison with other sample preparation techniques. Moreover, homogeneous liquid-liquid extraction is more suitable for the extraction of delicate macromolecules such as enzymes, hormones, and proteins and it is more compatible with liquid chromatography with tandem mass spectrometry, which is a vital technique in metabolomics and proteomics. In this review, the principle, types, applications, automation, and technical aspects of homogeneous liquid-liquid extraction are discussed.
Collapse
Affiliation(s)
- Sherin F Hammad
- Department of Pharmaceutical Analytical Chemistry, Faculty of Pharmacy, Tanta University, Tanta, Egypt
| | - Inas A Abdallah
- Department of Analytical Chemistry, Faculty of Pharmacy, University of Sadat City, Sadat City, Egypt
| | - Alaa Bedair
- Department of Analytical Chemistry, Faculty of Pharmacy, University of Sadat City, Sadat City, Egypt
| | - Fotouh R Mansour
- Department of Pharmaceutical Analytical Chemistry, Faculty of Pharmacy, Tanta University, Tanta, Egypt.,Pharmaceutical Services Center, Faculty of Pharmacy, Tanta University, Tanta, Egypt
| |
Collapse
|