1
|
Sajwan RK, Solanki PR. Gold@Carbon Quantum Dots Nanocomposites Based Two-In-One Sensor: A Novel Approach for Sensitive Detection of Aminoglycosides Antibiotics in Food Samples. Food Chem 2023; 415:135590. [PMID: 36870212 DOI: 10.1016/j.foodchem.2023.135590] [Citation(s) in RCA: 8] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/02/2022] [Revised: 01/25/2023] [Accepted: 01/25/2023] [Indexed: 02/05/2023]
Abstract
Antibiotics are life-saving drugs for humans, but their unwanted use leads to antibacterial resistance (ABR) and causes serious health problems. The excess of these antibiotics entered to the food chain and caused food contamination. Here, Au@CQDs nanocomposites (NCs) was used as a two-in-one sensor to detect two antibiotics. The color change of AuNCs and fluorescence resonance energy transfer are two distance-dependent phenomena used as sensing mechanisms. In the sensing process, Au@CQDs NCs change their color, enhancing the fluorescence intensity of NCs in the presence of Gentamicin (GENTA) and Kanamycin (KMC) antibiotics. The limit of detection of 116 nM and 133 nM for GENTA and 195 nM and 120 nM for KMC have been achieved with colorimetric and fluorimetric readout, respectively. The practicality of the reported sensor was evaluated in real spiked samples and showed excellent recovery efficiency. Therefore this two-in-one sensor can be used for the food monitoring system.
Collapse
Affiliation(s)
- Reena K Sajwan
- Nano-bio Laboratory, Special Center for Nanoscience, Jawaharlal Nehru University, New Delhi 110067, India
| | - Pratima R Solanki
- Nano-bio Laboratory, Special Center for Nanoscience, Jawaharlal Nehru University, New Delhi 110067, India.
| |
Collapse
|
2
|
Zhao Y, Wang X, Sun T, Shan P, Zhan Z, Zhao Z, Jiang Y, Qu M, Lv Q, Wang Y, Liu P, Chen S. Artificial intelligence-driven electrochemical immunosensing biochips in multi-component detection. BIOMICROFLUIDICS 2023; 17:041301. [PMID: 37614678 PMCID: PMC10444200 DOI: 10.1063/5.0160808] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 06/05/2023] [Accepted: 08/01/2023] [Indexed: 08/25/2023]
Abstract
Electrochemical Immunosensing (EI) combines electrochemical analysis and immunology principles and is characterized by its simplicity, rapid detection, high sensitivity, and specificity. EI has become an important approach in various fields, such as clinical diagnosis, disease prevention and treatment, environmental monitoring, and food safety. However, EI multi-component detection still faces two major bottlenecks: first, the lack of cost-effective and portable detection platforms; second, the difficulty in eliminating batch differences and accurately decoupling signals from multiple analytes. With the gradual maturation of biochip technology, high-throughput analysis and portable detection utilizing the advantages of miniaturized chips, high sensitivity, and low cost have become possible. Meanwhile, Artificial Intelligence (AI) enables accurate decoupling of signals and enhances the sensitivity and specificity of multi-component detection. We believe that by evaluating and analyzing the characteristics, benefits, and linkages of EI, biochip, and AI technologies, we may considerably accelerate the development of EI multi-component detection. Therefore, we propose three specific prospects: first, AI can enhance and optimize the performance of the EI biochips, addressing the issue of multi-component detection for portable platforms. Second, the AI-enhanced EI biochips can be widely applied in home care, medical healthcare, and other areas. Third, the cross-fusion and innovation of EI, biochip, and AI technologies will effectively solve key bottlenecks in biochip detection, promoting interdisciplinary development. However, challenges may arise from AI algorithms that are difficult to explain and limited data access. Nevertheless, we believe that with technological advances and further research, there will be more methods and technologies to overcome these challenges.
Collapse
Affiliation(s)
- Yuliang Zhao
- School of Control Engineering, Northeastern University at Qinhuangdao, Qinhuangdao 066000, Hebei, China
| | - Xiaoai Wang
- School of Control Engineering, Northeastern University at Qinhuangdao, Qinhuangdao 066000, Hebei, China
| | - Tingting Sun
- School of Control Engineering, Northeastern University at Qinhuangdao, Qinhuangdao 066000, Hebei, China
| | - Peng Shan
- School of Control Engineering, Northeastern University at Qinhuangdao, Qinhuangdao 066000, Hebei, China
| | - Zhikun Zhan
- School of Control Engineering, Northeastern University at Qinhuangdao, Qinhuangdao 066000, Hebei, China
| | - Zhongpeng Zhao
- State Key Laboratory of Pathogen and Biosecurity, Beijing Institute of Microbiology and Epidemiology, Academy of Military Medical Sciences (AMMS), Beijing 100071, China
| | - Yongqiang Jiang
- State Key Laboratory of Pathogen and Biosecurity, Beijing Institute of Microbiology and Epidemiology, Academy of Military Medical Sciences (AMMS), Beijing 100071, China
| | - Mingyue Qu
- The PLA Rocket Force Characteristic Medical Center, Beijing 100088, China
| | - Qingyu Lv
- State Key Laboratory of Pathogen and Biosecurity, Beijing Institute of Microbiology and Epidemiology, Academy of Military Medical Sciences (AMMS), Beijing 100071, China
| | - Ying Wang
- School of Biological Science and Medical Engineering, Beihang University, Beijing 100191, China
| | - Peng Liu
- State Key Laboratory of Pathogen and Biosecurity, Beijing Institute of Microbiology and Epidemiology, Academy of Military Medical Sciences (AMMS), Beijing 100071, China
| | - Shaolong Chen
- State Key Laboratory of Pathogen and Biosecurity, Beijing Institute of Microbiology and Epidemiology, Academy of Military Medical Sciences (AMMS), Beijing 100071, China
| |
Collapse
|
3
|
Rosa CE, Jorge FN, Luis GM, Juana CE, Edgar PD. 3D printed opto-microfluidic autonomous analyzer for photometric applications. HARDWAREX 2023; 14:e00406. [PMID: 36910021 PMCID: PMC9999204 DOI: 10.1016/j.ohx.2023.e00406] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 10/16/2022] [Revised: 02/08/2023] [Accepted: 02/17/2023] [Indexed: 06/18/2023]
Abstract
3D printed opto-microfluidic autonomous analyzer for photometric applications performs the automation of analytical micro-processes. The proposed device was designed under restrictions of small size and low energy consumption, which allow its portability for in-situ, on line and real time analysis. The autonomous process and auto-calibration consists of four functions: control and data acquisition; hydrodynamic: fluid pumping and flow injection; optical detection and wireless communication. All electronics systems where controlled with a virtual instrument interface. In the experiments carried out to measure fluorides, the results obtained were very close to those obtained with laboratory equipment. The consumption of reagents was 50% less and waste was reduced by 80%. The cost of the portable and autonomous microanalyzer is 75% less than large and robust laboratory equipment.
Collapse
Affiliation(s)
- Camarillo-Escobedo Rosa
- National Technological Institute of Mexico – La Laguna, Mechanic and Mechatronics Department, Blvd. Revolución & Calz. Cuauhtemoc S/N, Torreon, Coah., Mexico
- Universidad de Guadalajara-CUCEI, Translational Biomedical Engineering Department, Av. Revolución #1500, Guadalajara, Jal, Mexico
| | - Flores-Nuñez Jorge
- Universidad de Guadalajara-CUCEI, Translational Biomedical Engineering Department, Av. Revolución #1500, Guadalajara, Jal, Mexico
| | - García-Muñoz Luis
- National Technological Institute of Mexico – La Laguna, Computer System Department, Revolución & Calz. Cuauhtemoc S/N Torreon, Coah., Mexico
| | - Camarillo-Escobedo Juana
- National Technological Institute of Mexico – La Laguna, Electric and Electronic Department, Blvd. Revolución & Calz. Cuauhtemoc S/N, Torreon, Coah., Mexico
| | - Peña-Dominguez Edgar
- National Technological Institute of Mexico – La Laguna, Mechanic and Mechatronics Department, Blvd. Revolución & Calz. Cuauhtemoc S/N, Torreon, Coah., Mexico
| |
Collapse
|
4
|
Al‐Gawati MA, Albrithen H, Alhazaa AN, Alodhayb AN. Sensitivity enhancement of microelectromechanical sensors using femtosecond laser for biological and chemical applications. SURF INTERFACE ANAL 2022. [DOI: 10.1002/sia.7132] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/05/2022]
Affiliation(s)
- Mahmoud A. Al‐Gawati
- Department of Physics and Astronomy, College of Science King Saud University Riyadh Saudi Arabia
- King Abdullah Institute for Nanotechnology King Saud University Riyadh Saudi Arabia
| | - Hamad Albrithen
- Department of Physics and Astronomy, College of Science King Saud University Riyadh Saudi Arabia
- King Abdullah Institute for Nanotechnology King Saud University Riyadh Saudi Arabia
- Research Chair for Tribology, Surface, and Interface Sciences, Department of Physics and Astronomy, College of Science King Saud University Riyadh Saudi Arabia
| | - Abdulaziz N. Alhazaa
- Department of Physics and Astronomy, College of Science King Saud University Riyadh Saudi Arabia
- King Abdullah Institute for Nanotechnology King Saud University Riyadh Saudi Arabia
- Research Chair for Tribology, Surface, and Interface Sciences, Department of Physics and Astronomy, College of Science King Saud University Riyadh Saudi Arabia
| | - Abdullah N. Alodhayb
- Department of Physics and Astronomy, College of Science King Saud University Riyadh Saudi Arabia
- King Abdullah Institute for Nanotechnology King Saud University Riyadh Saudi Arabia
- Research Chair for Tribology, Surface, and Interface Sciences, Department of Physics and Astronomy, College of Science King Saud University Riyadh Saudi Arabia
| |
Collapse
|
5
|
Singh SK, Srinivasan A, Mitra S, Gooh Pattader PS. Carbon dots and Methylene blue facilitated photometric quantification of Hemoglobin. SPECTROCHIMICA ACTA. PART A, MOLECULAR AND BIOMOLECULAR SPECTROSCOPY 2022; 271:120906. [PMID: 35077978 DOI: 10.1016/j.saa.2022.120906] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 11/09/2021] [Revised: 01/08/2022] [Accepted: 01/13/2022] [Indexed: 06/14/2023]
Abstract
Early detection and monitoring of any abnormality of Hemoglobin (Hb) concentration in whole blood samples are important as this may be related to anemia, leukemia, dengue, etc. To facilitate quantitative detection and to monitor the hemoglobin level in the blood, we attempt to develop a low-cost, portable point of care (POC) device based on the spectrophotometric principle. Optical sensitivities of carbon quantum dots (CDs) are found to be highly responsive, while there is a selective reaction between Hb and reduced form of Methylene Blue (MBred). The interaction of Hb, MBred, and CDs is delineated using UV-Visible (UV-Vis) spectroscopy. CDs have a characteristic UV-Vis peak at ∼ 347 nm, and it shows a gradual increase in intensity with a slight red shift (∼355 nm) on the progressive increase in Hb concentration. Simultaneously, the colorless MBred is oxidized to its blue oxidized form MBox and its characteristic peak starts reappearing at ∼ 663 nm. These responses are exploited to quantify Hb concentration with a limit of detection (LOD) as low as ∼ 2 g dL-1 in a developed POC device, and the results are validated with the clinical data obtained from a local hospital with reasonably good agreement. This photometric detection approach can be adopted for other quantitative biosensors.
Collapse
Affiliation(s)
- Sunil Kumar Singh
- Department of Chemical Engineering, Indian Institute of Technology Guwahati, Assam 781039, India
| | - Aishwarya Srinivasan
- Department of Chemical Engineering, Indian Institute of Technology Guwahati, Assam 781039, India
| | - Shirsendu Mitra
- Department of Chemical Engineering, Indian Institute of Technology Guwahati, Assam 781039, India.
| | - Partho Sarathi Gooh Pattader
- Department of Chemical Engineering, Indian Institute of Technology Guwahati, Assam 781039, India; Centre for Nanotechnology, Indian Institute of Technology Guwahati, Assam 781039, India; School of Health Science and Technology, Indian Institute of Technology Guwahati, Assam 781039, India.
| |
Collapse
|
6
|
|
7
|
Kumemura M, Pekin D, Menon VA, Van Seuningen I, Collard D, Tarhan MC. Fabricating Silicon Resonators for Analysing Biological Samples. MICROMACHINES 2021; 12:1546. [PMID: 34945396 PMCID: PMC8708134 DOI: 10.3390/mi12121546] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 11/04/2021] [Revised: 12/08/2021] [Accepted: 12/10/2021] [Indexed: 11/17/2022]
Abstract
The adaptability of microscale devices allows microtechnologies to be used for a wide range of applications. Biology and medicine are among those fields that, in recent decades, have applied microtechnologies to achieve new and improved functionality. However, despite their ability to achieve assay sensitivities that rival or exceed conventional standards, silicon-based microelectromechanical systems remain underutilised for biological and biomedical applications. Although microelectromechanical resonators and actuators do not always exhibit optimal performance in liquid due to electrical double layer formation and high damping, these issues have been solved with some innovative fabrication processes or alternative experimental approaches. This paper focuses on several examples of silicon-based resonating devices with a brief look at their fundamental sensing elements and key fabrication steps, as well as current and potential biological/biomedical applications.
Collapse
Affiliation(s)
- Momoko Kumemura
- Graduate School of Life Science and Systems Engineering, Kyushu Institute of Technology, 2-4 Hibikino, Wakamatsu-ku, Kitakyushu-shi, Fukuoka 808-0196, Japan;
- LIMMS/CNRS-IIS, Institute of Industrial Science, The University of Tokyo, 4-6-1 Komaba, Meguro-ku, Tokyo 153-8505, Japan; (D.P.); (D.C.)
| | - Deniz Pekin
- LIMMS/CNRS-IIS, Institute of Industrial Science, The University of Tokyo, 4-6-1 Komaba, Meguro-ku, Tokyo 153-8505, Japan; (D.P.); (D.C.)
- CNRS/IIS/COL/Lille University, SMMiL-E Project, CNRS Délégation Nord-Pas de Calais et Picardie, 2 rue de Canonniers, CEDEX, 59046 Lille, France
- Univ. Lille, CNRS, Inserm, CHU Lille, UMR9020-U1277—CANTHER—Cancer Heterogeneity Plasticity and Resistance to Therapies, F-59000 Lille, France;
| | - Vivek Anand Menon
- Division of Mechanical Science and Technology, Gunma University, 1-5-1 Tenjin-cho, Kiryu-shi, Gunma 376-8515, Japan;
| | - Isabelle Van Seuningen
- Univ. Lille, CNRS, Inserm, CHU Lille, UMR9020-U1277—CANTHER—Cancer Heterogeneity Plasticity and Resistance to Therapies, F-59000 Lille, France;
| | - Dominique Collard
- LIMMS/CNRS-IIS, Institute of Industrial Science, The University of Tokyo, 4-6-1 Komaba, Meguro-ku, Tokyo 153-8505, Japan; (D.P.); (D.C.)
- CNRS/IIS/COL/Lille University, SMMiL-E Project, CNRS Délégation Nord-Pas de Calais et Picardie, 2 rue de Canonniers, CEDEX, 59046 Lille, France
| | - Mehmet Cagatay Tarhan
- LIMMS/CNRS-IIS, Institute of Industrial Science, The University of Tokyo, 4-6-1 Komaba, Meguro-ku, Tokyo 153-8505, Japan; (D.P.); (D.C.)
- CNRS/IIS/COL/Lille University, SMMiL-E Project, CNRS Délégation Nord-Pas de Calais et Picardie, 2 rue de Canonniers, CEDEX, 59046 Lille, France
- Univ. Lille, CNRS, Centrale Lille, Junia, University Polytechnique Hauts-de-France, UMR 8520—IEMN, Institut
d’Electronique de Microélectronique et de Nanotechnologie, F-59000 Lille, France
| |
Collapse
|
8
|
Recent Progress in Electrochemical Immunosensors. BIOSENSORS-BASEL 2021; 11:bios11100360. [PMID: 34677316 PMCID: PMC8533705 DOI: 10.3390/bios11100360] [Citation(s) in RCA: 33] [Impact Index Per Article: 8.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 08/31/2021] [Revised: 09/17/2021] [Accepted: 09/27/2021] [Indexed: 12/11/2022]
Abstract
Biosensors used for medical diagnosis work by analyzing physiological fluids. Antibodies have been frequently used as molecular recognition molecules for the specific binding of target analytes from complex biological solutions. Electrochemistry has been introduced for the measurement of quantitative signals from transducer-bound analytes for many reasons, including good sensitivity. Recently, numerous electrochemical immunosensors have been developed and various strategies have been proposed to detect biomarkers. In this paper, the recent progress in electrochemical immunosensors is reviewed. In particular, we focused on the immobilization methods using antibodies for voltammetric, amperometric, impedimetric, and electrochemiluminescent immunosensors.
Collapse
|
9
|
Mere V, Dash A, Kallega R, Pratap R, Naik A, Selvaraja SK. On-chip silicon photonics based grating assisted vibration sensor. OPTICS EXPRESS 2020; 28:27495-27505. [PMID: 32988042 DOI: 10.1364/oe.394393] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 04/02/2020] [Accepted: 08/19/2020] [Indexed: 06/11/2023]
Abstract
We present a compact, highly sensitive and scalable on-chip photonic vibration measurement scheme for vibration sensing. The scheme uses a silicon photonic diffraction-grating based sensor integrated underneath a silicon cantilever. We demonstrate a static and dynamic measurement sensitivity (ΔT/Δgap) of 0.6 % change in intensity per nm displacement. The electrostatically driven dynamic response measurement of the grating based sensor shows an excellent agreement with commercial Laser Doppler Vibrometer (LDV) measurement. We demonstrate the thermo-mechanical noise measurement on the cantilever in ambience, which is verified using LDV. A minimum displacement of 1.9 pm is measured with a displacement sensitivity of 10 μW/nm for a measurement bandwidth of 16 Hz. The demonstrated sensitivity is 2 orders of magnitude better than that obtained from measurements of static displacement. We also present a detailed 2D-FDTD simulation and optimization of the grating-based sensor to achieve maximum displacement sensitivity.
Collapse
|
10
|
Rezaei Z, Mahmoudifard M. Pivotal role of electrospun nanofibers in microfluidic diagnostic systems - a review. J Mater Chem B 2020; 7:4602-4619. [PMID: 31364667 DOI: 10.1039/c9tb00682f] [Citation(s) in RCA: 23] [Impact Index Per Article: 4.6] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/12/2022]
Abstract
Recently, the usage of electrospinning technology for the fabrication of fine fibers with a good deal of variation in morphology and structure has drawn the attention of many researchers around the world. These fibers have found their way in the many fields of science including medical diagnosis, tissue engineering, drug delivery, replica molding, solar cells, catalysts, energy conversion and storage, physical and chemical sensors and other applications. Among all applications, biosensing with the aim of rapid and sensitive biomarker detection is an area that warrants attention. Electrospun nanofibrous membranes enjoy numerous factors which benefit them to be used as potential candidates in biosensing platforms. Some of these factors include a high surface to volume ratio, analogous scale compared to bioactive molecules and relatively defect-free properties of nanofibers (NFs). In this review, we focused on the recent advances in electrospun nanofibrous membrane-based micro-analytical devices with an application as diagnostic systems. Hence, a study on the electrospun nanofiber usage in lab-on-a-chip and paper-based point-of-care devices, with an opening introduction to biosensors, nanofibers, the electrospinning method, and microfluidics as the principles of the intended subject, is provided. It is anticipated that the given examples in this paper will provide sufficient evidence for the potential of electrospun NFs for being used as a substrate in the commercial fabrication of highly sensitive and selective biosensors.
Collapse
Affiliation(s)
- Zahra Rezaei
- Department of Industrial and Environmental Biotechnology, National Institute of Genetic Engineering and Biotechnology, Tehran, Iran and Chemical & Petroleum Engineering Department, Sharif University of Technology, Tehran, Iran.
| | - Matin Mahmoudifard
- Department of Industrial and Environmental Biotechnology, National Institute of Genetic Engineering and Biotechnology, Tehran, Iran
| |
Collapse
|
11
|
Alunda BO, Lee YJ. Review: Cantilever-Based Sensors for High Speed Atomic Force Microscopy. SENSORS (BASEL, SWITZERLAND) 2020; 20:E4784. [PMID: 32854193 PMCID: PMC7506678 DOI: 10.3390/s20174784] [Citation(s) in RCA: 17] [Impact Index Per Article: 3.4] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 07/23/2020] [Revised: 08/11/2020] [Accepted: 08/12/2020] [Indexed: 12/13/2022]
Abstract
This review critically summarizes the recent advances of the microcantilever-based force sensors for atomic force microscope (AFM) applications. They are one the most common mechanical spring-mass systems and are extremely sensitive to changes in the resonant frequency, thus finding numerous applications especially for molecular sensing. Specifically, we comment on the latest progress in research on the deflection detection systems, fabrication, coating and functionalization of the microcantilevers and their application as bio- and chemical sensors. A trend on the recent breakthroughs on the study of biological samples using high-speed atomic force microscope is also reported in this review.
Collapse
Affiliation(s)
- Bernard Ouma Alunda
- School of Mines and Engineering, Taita Taveta University, P.O. Box 635-80300 Voi, Kenya;
| | - Yong Joong Lee
- School of Mechanical Engineering, Kyungpook National University, Daegu 41566, Korea
| |
Collapse
|
12
|
Farhoudi N, Leu HY, Laurentius LB, Magda JJ, Solzbacher F, Reiche CF. Smart Hydrogel Micromechanical Resonators with Ultrasound Readout for Biomedical Sensing. ACS Sens 2020; 5:1882-1889. [PMID: 32545953 DOI: 10.1021/acssensors.9b02180] [Citation(s) in RCA: 14] [Impact Index Per Article: 2.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/06/2023]
Abstract
One of the main challenges for implantable biomedical sensing schemes is obtaining a reliable signal while maintaining biocompatibility. In this work, we demonstrate that a combination of medical ultrasound imaging and smart hydrogel micromechanical resonators can be employed for continuous monitoring of analyte concentrations. The sensing principle is based on the shift of the mechanical resonance frequencies of smart hydrogel structures induced by their volume-phase transition in response to changing analyte levels. This shift can then be measured as a contrast change in the ultrasound images due to resonance absorption of ultrasound waves. This concept eliminates the need for implanting complex electronics or employing transcutaneous connections for sensing biomedical analytes in vivo. Here, we present proof-of-principle experiments that monitor in vitro changes in ionic strength and glucose concentrations to demonstrate the capabilities and potential of this versatile sensing platform technology.
Collapse
Affiliation(s)
- Navid Farhoudi
- Department of Electrical and Computer Engineering, University of Utah, Salt Lake City, Utah 84112, United States
| | - Hsuan-Yu Leu
- Department of Chemical Engineering, University of Utah, Salt Lake City, Utah 84112, United States
| | - Lars B. Laurentius
- Department of Electrical and Computer Engineering, University of Utah, Salt Lake City, Utah 84112, United States
| | - Jules J. Magda
- Department of Chemical Engineering, University of Utah, Salt Lake City, Utah 84112, United States
| | - Florian Solzbacher
- Department of Electrical and Computer Engineering, University of Utah, Salt Lake City, Utah 84112, United States
- Department of Materials Science & Engineering, University of Utah, Salt Lake City, Utah 84112, United States
- Department of Bioengineering, University of Utah, Salt Lake City, Utah 84112, United States
| | - Christopher F. Reiche
- Department of Electrical and Computer Engineering, University of Utah, Salt Lake City, Utah 84112, United States
| |
Collapse
|
13
|
Mohanta YK, Hashem A, Abd_Allah EF, Jena SK, Mohanta TK. Bacterial synthesized metal and metal salt nanoparticles in biomedical applications: An up and coming approach. Appl Organomet Chem 2020. [DOI: 10.1002/aoc.5810] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/18/2023]
Affiliation(s)
| | - Abeer Hashem
- Botany and Microbiology DepartmentKing Saud University Riyadh 11451 Saudi Arabia
| | | | - Santosh Kumar Jena
- Department of BiotechnologyNorth Orissa University Baripada 757003 India
| | - Tapan Kumar Mohanta
- Natural and Medical Sciences Research CenterUniversity of Nizwa Nizwa 616 Oman
| |
Collapse
|
14
|
Grogan C, Amarandei G, Lawless S, Pedreschi F, Lyng F, Benito-Lopez F, Raiteri R, Florea L. Silicon Microcantilever Sensors to Detect the Reversible Conformational Change of a Molecular Switch, Spiropyan. SENSORS (BASEL, SWITZERLAND) 2020; 20:E854. [PMID: 32041095 PMCID: PMC7039217 DOI: 10.3390/s20030854] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 12/17/2019] [Revised: 01/22/2020] [Accepted: 01/31/2020] [Indexed: 12/13/2022]
Abstract
The high sensitivity of silicon microcantilever sensors has expanded their use in areas ranging from gas sensing to bio-medical applications. Photochromic molecules also represent promising candidates for a large variety of sensing applications. In this work, the operating principles of these two sensing methods are combined in order to detect the reversible conformational change of a molecular switch, spiropyran. Thus, arrays of silicon microcantilever sensors were functionalized with spiropyran on the gold covered side and used as test microcantilevers. The microcantilever deflection response was observed, in five sequential cycles, as the transition from the spiropyran (SP) (CLOSED) to the merocyanine (MC) (OPEN) state and vice-versa when induced by UV and white light LED sources, respectively, proving the reversibility capabilities of this type of sensor. The microcantilever deflection direction was observed to be in one direction when changing to the MC state and in the opposite direction when changing back to the SP state. A tensile stress was induced in the microcantilever when the SP to MC transition took place, while a compressive stress was observed for the reverse transition. These different type of stresses are believed to be related to the spatial conformational changes induced in the photochromic molecule upon photo-isomerisation.
Collapse
Affiliation(s)
- Catherine Grogan
- School of Physics & Clinical & Optometric Sciences, Technological University of Dublin, Kevin Street, D08NF82 Dublin, Ireland; (C.G.); (G.A.); (F.P.); (F.L.)
| | - George Amarandei
- School of Physics & Clinical & Optometric Sciences, Technological University of Dublin, Kevin Street, D08NF82 Dublin, Ireland; (C.G.); (G.A.); (F.P.); (F.L.)
| | - Shauna Lawless
- Insight Centre for Data Analytics, National Centre for Sensor Research, Dublin City University, 9 Dublin, Ireland;
| | - Fran Pedreschi
- School of Physics & Clinical & Optometric Sciences, Technological University of Dublin, Kevin Street, D08NF82 Dublin, Ireland; (C.G.); (G.A.); (F.P.); (F.L.)
| | - Fiona Lyng
- School of Physics & Clinical & Optometric Sciences, Technological University of Dublin, Kevin Street, D08NF82 Dublin, Ireland; (C.G.); (G.A.); (F.P.); (F.L.)
- FOCAS Institute, Technological University Dublin, Camden Row, 8 Dublin, Ireland
| | - Fernando Benito-Lopez
- Analytical Microsystems & Materials for Lab-on-a-Chip Group (AMMa-LOAC), Microfluidics Cluster UPV/EHU, Analytical Chemistry Department, University of the Basque Country UPV/EHU, 01006 Vitoria-Gasteiz, Spain;
| | - Roberto Raiteri
- Department of Informatics, Bioengineering, Robotics and System Engineering, University of Genova, 16145 Genova, Italy;
| | - Larisa Florea
- School of Chemistry & AMBER, the SFI Research Centre for Advanced Materials and BioEngineering Research, Trinity College Dublin, the University of Dublin, College Green, 2 Dublin, Ireland
| |
Collapse
|
15
|
|
16
|
Garzón V, Pinacho DG, Bustos RH, Garzón G, Bustamante S. Optical Biosensors for Therapeutic Drug Monitoring. BIOSENSORS 2019; 9:E132. [PMID: 31718050 PMCID: PMC6955905 DOI: 10.3390/bios9040132] [Citation(s) in RCA: 45] [Impact Index Per Article: 7.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 09/04/2019] [Revised: 10/30/2019] [Accepted: 11/01/2019] [Indexed: 12/26/2022]
Abstract
Therapeutic drug monitoring (TDM) is a fundamental tool when administering drugs that have a limited dosage or high toxicity, which could endanger the lives of patients. To carry out this monitoring, one can use different biological fluids, including blood, plasma, serum, and urine, among others. The help of specialized methodologies for TDM will allow for the pharmacodynamic and pharmacokinetic analysis of drugs and help adjust the dose before or during their administration. Techniques that are more versatile and label free for the rapid quantification of drugs employ biosensors, devices that consist of one element for biological recognition coupled to a signal transducer. Among biosensors are those of the optical biosensor type, which have been used for the quantification of different molecules of clinical interest, such as antibiotics, anticonvulsants, anti-cancer drugs, and heart failure. This review presents an overview of TDM at the global level considering various aspects and clinical applications. In addition, we review the contributions of optical biosensors to TDM.
Collapse
Affiliation(s)
- Vivian Garzón
- Doctoral Programme of Biosciences, Universidad de La Sabana, Chía 140013, Colombia
- Therapeutic Evidence Group, Clinical Pharmacology, Universidad de La Sabana, Chía 140013, Colombia
| | - Daniel G. Pinacho
- Therapeutic Evidence Group, Clinical Pharmacology, Universidad de La Sabana, Chía 140013, Colombia
| | - Rosa-Helena Bustos
- Therapeutic Evidence Group, Clinical Pharmacology, Universidad de La Sabana, Chía 140013, Colombia
| | - Gustavo Garzón
- Faculty of Medicine, Universidad de La Sabana, Chía 140013, Colombia
| | - Sandra Bustamante
- Physics Department, the Centre for NanoHealth, Swansea University, Swansea SA2 8PP, UK
- Vedas, Corporación de Investigación e Innovación, Medellín 050001, Colombia
| |
Collapse
|
17
|
Jing Y, Fan G, Wang R, Zhang Z, Cai X, Wei J, Chen X, Li H, Li Y. Improved Optical Waveguide Microcantilever for Integrated Nanomechanical Sensor. SENSORS 2019; 19:s19194346. [PMID: 31597318 PMCID: PMC6806205 DOI: 10.3390/s19194346] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 08/19/2019] [Revised: 09/25/2019] [Accepted: 10/03/2019] [Indexed: 11/18/2022]
Abstract
This paper reports on an improved optical waveguide microcantilever sensor with high sensitivity. To improve the sensitivity, a buffer was introduced into the connection of the input waveguide and optical waveguide cantilever by extending the input waveguide to reduce the coupling loss of the junction. The buffer-associated optical losses were examined for different cantilever thicknesses. The optimum length of the buffer was found to be 0.97 μm for a cantilever thickness of 300 nm. With this configuration, the optical loss was reduced to about 40%, and the maximum sensitivity was more than twice that of the conventional structure.
Collapse
Affiliation(s)
- Yachao Jing
- Key Laboratory of All Optical Network and Advanced Telecommunication Network, Ministry of Education, Institute of Lightwave Technology, Beijing Jiaotong University, Beijing 100044, China; (Y.J.); (R.W.); (Z.Z.)
| | - Guofang Fan
- Key Laboratory of All Optical Network and Advanced Telecommunication Network, Ministry of Education, Institute of Lightwave Technology, Beijing Jiaotong University, Beijing 100044, China; (Y.J.); (R.W.); (Z.Z.)
- Correspondence: (G.F.); (Y.L.)
| | - Rongwei Wang
- Key Laboratory of All Optical Network and Advanced Telecommunication Network, Ministry of Education, Institute of Lightwave Technology, Beijing Jiaotong University, Beijing 100044, China; (Y.J.); (R.W.); (Z.Z.)
| | - Zeping Zhang
- Key Laboratory of All Optical Network and Advanced Telecommunication Network, Ministry of Education, Institute of Lightwave Technology, Beijing Jiaotong University, Beijing 100044, China; (Y.J.); (R.W.); (Z.Z.)
| | - Xiaoyu Cai
- Shanghai Institute of Measurement and Testing Technology, National Center of Measurement and Testing for East China, National Center of Testing Technology, Shanghai 201203, China; (X.C.); (J.W.)
| | - Jiasi Wei
- Shanghai Institute of Measurement and Testing Technology, National Center of Measurement and Testing for East China, National Center of Testing Technology, Shanghai 201203, China; (X.C.); (J.W.)
| | - Xin Chen
- Department of Instrument Science and Engineering, Shanghai Jiao Tong University, Shanghai 200240, China;
| | - Hongyu Li
- College of Mechanical and Electronic Engineering, Shandong University of Science and Technology, Qingdao 266590, China;
| | - Yuan Li
- Shanghai Institute of Measurement and Testing Technology, National Center of Measurement and Testing for East China, National Center of Testing Technology, Shanghai 201203, China; (X.C.); (J.W.)
- Correspondence: (G.F.); (Y.L.)
| |
Collapse
|
18
|
Hassan RA, Heng LY, Ahmad A, Tan LL. Rapid determination of kappa-carrageenan using a biosensor from immobilized Pseudomonas carrageenovora cells. PLoS One 2019; 14:e0214580. [PMID: 30990847 PMCID: PMC6467376 DOI: 10.1371/journal.pone.0214580] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/08/2018] [Accepted: 03/17/2019] [Indexed: 11/18/2022] Open
Abstract
A potentiometric whole cell biosensor based on immobilized marine bacterium, Pseudomonas carrageenovora producing κ-carrageenase and glycosulfatase enzymes for specific and direct determination of κ-carrageenan, is described. The bacterial cells were immobilized on the self-plasticized hydrogen ion (H+)-selective acrylic membrane electrode surface to form a catalytic layer. Hydrogen ionophore I was incorporated in the poly(n-butyl acrylate) [poly(nBA)] as a pH ionophore. Catalytic decomposition of κ-carrageenan by the bienzymatic cascade reaction produced neoagarobiose, an inorganic sulfate ion and a proton. The latter was detectable by H+ ion transducer for indirect potentiometric quantification of κ-carrageenan concentration. The use of a disposable screen-printed Ag/AgCl electrode (SPE) provided no cleaning requirement and enabled κ-carrageenan detection to be carried out conveniently without cross contamination in a complex food sample. The SPE-based microbial biosensor response was found to be reproducible with high reproducibility and relative standard deviation (RSD) at 2.6% (n = 3). The whole cell biosensor demonstrated a broad dynamic linear response range to κ-carrageenan from 0.2-100 ppm in 20 mM phosphate buffer saline (PBS) at pH 7.5 with a detection limit at 0.05 ppm and a Nernstian sensitivity of 58.78±0.87 mV/decade (R2 = 0.995). The biosensor showed excellent selectivity towards κ-carrageenan compared to other types of carrageenans tested e.g. ι-carrageenan and λ-carrageenan. No pretreatment to the food sample was necessary when the developed whole cell biosensor was employed for direct assay of κ-carrageenan in dairy product.
Collapse
Affiliation(s)
- Riyadh Abdulmalek Hassan
- School of Chemical Sciences and Food Technology, Faculty of Science and Technology, Universiti Kebangsaan Malaysia, UKM Bangi, Selangor Darul Ehsan, Malaysia
- Department of Chemistry, Faculty of Science, Ibb University, Ibb, Republic of Yemen
| | - Lee Yook Heng
- School of Chemical Sciences and Food Technology, Faculty of Science and Technology, Universiti Kebangsaan Malaysia, UKM Bangi, Selangor Darul Ehsan, Malaysia
- Southeast Asia Disaster Prevention Research Initiative (SEADPRI-UKM), LESTARI, Universiti Kebangsaan Malaysia, UKM Bangi, Selangor Darul Ehsan, Malaysia
| | - Asmat Ahmad
- School of Biosciences and Biotechnology, Faculty of Science and Technology, Universiti Kebangsaan Malaysia, Bangi, Selangor Darul Ehsan, Malaysia
| | - Ling Ling Tan
- Southeast Asia Disaster Prevention Research Initiative (SEADPRI-UKM), LESTARI, Universiti Kebangsaan Malaysia, UKM Bangi, Selangor Darul Ehsan, Malaysia
| |
Collapse
|
19
|
Atomic force microscopy-based cancer diagnosis by detecting cancer-specific biomolecules and cells. Biochim Biophys Acta Rev Cancer 2019; 1871:367-378. [DOI: 10.1016/j.bbcan.2019.03.002] [Citation(s) in RCA: 15] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/30/2019] [Revised: 03/21/2019] [Accepted: 03/26/2019] [Indexed: 02/07/2023]
|
20
|
Orientation Control of the Molecular Recognition Layer for Improved Sensitivity: a Review. BIOCHIP JOURNAL 2019. [DOI: 10.1007/s13206-019-3103-0] [Citation(s) in RCA: 28] [Impact Index Per Article: 4.7] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 12/29/2022]
|
21
|
Azharuddin M, Zhu GH, Das D, Ozgur E, Uzun L, Turner APF, Patra HK. A repertoire of biomedical applications of noble metal nanoparticles. Chem Commun (Camb) 2019; 55:6964-6996. [DOI: 10.1039/c9cc01741k] [Citation(s) in RCA: 161] [Impact Index Per Article: 26.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/11/2022]
Abstract
The emerging properties of noble metal nanoparticles are attracting huge interest from the translational scientific community. In this feature article, we highlight recent advances in the adaptation of noble metal nanomaterials and their biomedical applications in therapeutics, diagnostics and sensing.
Collapse
Affiliation(s)
- Mohammad Azharuddin
- Department of Clinical and Experimental Medicine
- Linkoping University
- Linkoping
- Sweden
| | - Geyunjian H. Zhu
- Department of Chemical Engineering and Biotechnology
- University of Cambridge
- Cambridge
- UK
| | - Debapratim Das
- Department of Chemistry
- Indian Institute of Technology Guwahati
- India
| | - Erdogan Ozgur
- Hacettepe University
- Faculty of Science
- Department of Chemistry
- Ankara
- Turkey
| | - Lokman Uzun
- Hacettepe University
- Faculty of Science
- Department of Chemistry
- Ankara
- Turkey
| | | | - Hirak K. Patra
- Department of Clinical and Experimental Medicine
- Linkoping University
- Linkoping
- Sweden
- Department of Chemical Engineering and Biotechnology
| |
Collapse
|
22
|
Biosensors for wastewater monitoring: A review. Biosens Bioelectron 2018; 118:66-79. [PMID: 30056302 DOI: 10.1016/j.bios.2018.07.019] [Citation(s) in RCA: 98] [Impact Index Per Article: 14.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/06/2018] [Revised: 07/07/2018] [Accepted: 07/09/2018] [Indexed: 02/06/2023]
Abstract
Water pollution and habitat degradation are the cause of increasing water scarcity and decline in aquatic biodiversity. While the freshwater availability has been declining through past decades, water demand has continued to increase particularly in areas with arid and semi-arid climate. Monitoring of pollutants in wastewater effluents are critical to identifying water pollution area for treatment. Conventional detection methods are not effective in tracing multiple harmful components in wastewater due to their variability along different times and sources. Currently, the development of biosensing instruments attracted significant attention because of their high sensitivity, selectivity, reliability, simplicity, low-cost and real-time response. This paper provides a general overview on reported biosensors, which have been applied for the recognition of important organic chemicals, heavy metals, and microorganisms in dark waters. The significance and successes of nanotechnology in the field of biomolecular detection are also reviewed. The commercially available biosensors and their main challenges in wastewater monitoring are finally discussed.
Collapse
|
23
|
Cristea C, Tertis M, Galatus R. Magnetic Nanoparticles for Antibiotics Detection. NANOMATERIALS (BASEL, SWITZERLAND) 2017; 7:E119. [PMID: 28538684 PMCID: PMC5485766 DOI: 10.3390/nano7060119] [Citation(s) in RCA: 36] [Impact Index Per Article: 4.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 03/30/2017] [Revised: 05/16/2017] [Accepted: 05/17/2017] [Indexed: 12/27/2022]
Abstract
Widespread use of antibiotics has led to pollution of waterways, potentially creating resistance among freshwater bacterial communities. Microorganisms resistant to commonly prescribed antibiotics (superbug) have dramatically increased over the last decades. The presence of antibiotics in waters, in food and beverages in both their un-metabolized and metabolized forms are of interest for humans. This is due to daily exposure in small quantities, that, when accumulated, could lead to development of drug resistance to antibiotics, or multiply the risk of allergic reaction. Conventional analytical methods used to quantify antibiotics are relatively expensive and generally require long analysis time associated with the difficulties to perform field analyses. In this context, electrochemical and optical based sensing devices are of interest, offering great potentials for a broad range of analytical applications. This review will focus on the application of magnetic nanoparticles in the design of different analytical methods, mainly sensors, used for the detection of antibiotics in different matrices (human fluids, the environmental, food and beverages samples).
Collapse
Affiliation(s)
- Cecilia Cristea
- Analytical Chemistry Department, Faculty of Pharmacy, Iuliu Haţieganu University of Medicine and Pharmacy, 4 Pasteur St., 400349 Cluj-Napoca, Romania.
| | - Mihaela Tertis
- Analytical Chemistry Department, Faculty of Pharmacy, Iuliu Haţieganu University of Medicine and Pharmacy, 4 Pasteur St., 400349 Cluj-Napoca, Romania.
| | - Ramona Galatus
- Basis of Electronics Department, Faculty of Electronics, Telecommunication and Information Technology, Technical University of Cluj-Napoca, 28 Memorandumului St., 400114 Cluj-Napoca, Romania.
| |
Collapse
|
24
|
Choi YS, Gwak MJ, Lee DW. Polymeric cantilever integrated with PDMS/graphene composite strain sensor. THE REVIEW OF SCIENTIFIC INSTRUMENTS 2016; 87:105004. [PMID: 27802725 DOI: 10.1063/1.4962925] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/06/2023]
Abstract
This paper describes the mechanical and electrical characteristics of a polydimethylsiloxane (PDMS) cantilever integrated with a high-sensitivity strain sensor. The strain sensor is fabricated using PDMS and graphene flakes that are uniformly distributed in the PDMS. In order to prepare PDMS/graphene composite with uniform resistance, a tetrahydrofuran solution is used to decrease the viscosity of a PDMS base polymer solution. A horn-type sonicator is then used to mix the base polymer with graphene flakes. Low viscosity of the base polymer solution improves the reliability and reproducibility of the PDMS/graphene composite for strain sensor applications. After dicing the composite into the desired sensor shape, a tensile test is performed. The experimental results show that the composite with a concentration of 30 wt.% exhibits a linear response up to a strain rate of 9%. The graphene concentration of the prepared materials affects the gauge factor, which at 20% graphene concentration reaches about 50, and with increasing graphene concentration to 30% decreases to 9. Furthermore, photolithography, PDMS casting, and a stencil process are used to fabricate a PDMS cantilever with an integrated strain sensor. The change in resistance of the integrated PDMS/graphene sensor is characterized with respect to the displacement of the cantilever of within 500 μm. The experimental results confirmed that the prepared PDMS/graphene based sensor has the potential for high-sensitive biosensor applications.
Collapse
Affiliation(s)
- Young-Soo Choi
- MEMS and Nanotechnology Lab, School of Mechanical Engineering Chonnam National University, Gwangju 500757, South Korea
| | - Min-Joo Gwak
- MEMS and Nanotechnology Lab, School of Mechanical Engineering Chonnam National University, Gwangju 500757, South Korea
| | - Dong-Weon Lee
- MEMS and Nanotechnology Lab, School of Mechanical Engineering Chonnam National University, Gwangju 500757, South Korea
| |
Collapse
|
25
|
Goponenko AV, Dzenis YA. Role of Mechanical Factors in Applications of Stimuli-Responsive Polymer Gels - Status and Prospects. POLYMER 2016; 101:415-449. [PMID: 28348443 PMCID: PMC5365095 DOI: 10.1016/j.polymer.2016.08.068] [Citation(s) in RCA: 27] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/24/2022]
Abstract
Due to their unique characteristics such as multifold change of volume in response to minute change in the environment, resemblance of soft biological tissues, ability to operate in wet environments, and chemical tailorability, stimuli responsive gels represent a versatile and very promising class of materials for sensors, muscle-type actuators, biomedical applications, and autonomous intelligent structures. Success of these materials in practical applications largely depends on their ability to fulfill application-specific mechanical requirements. This article provides an overview of recent application-driven development of covalent polymer gels with special emphasis on the relevant mechanical factors and properties. A short account of mechanisms of gel swelling and mechanical characteristics of importance to stimuli-responsive gels is presented. The review highlights major barriers for wider application of these materials and discusses latest advances and potential future directions toward overcoming these barriers, including interpenetrating networks, homogeneous networks, nanocomposites, and nanofilamentary gels.
Collapse
Affiliation(s)
- Alexander V. Goponenko
- Department of Mechanical and Materials Engineering and Nebraska Center for Materials and Nanoscience, University of Nebraska, Lincoln, NE 68588, USA
| | - Yuris A. Dzenis
- Department of Mechanical and Materials Engineering and Nebraska Center for Materials and Nanoscience, University of Nebraska, Lincoln, NE 68588, USA
| |
Collapse
|
26
|
Toren P, Ozgur E, Bayindir M. Oligonucleotide-based label-free detection with optical microresonators: strategies and challenges. LAB ON A CHIP 2016; 16:2572-2595. [PMID: 27306702 DOI: 10.1039/c6lc00521g] [Citation(s) in RCA: 13] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/06/2023]
Abstract
This review targets diversified oligonucleotide-based biodetection techniques, focusing on the use of microresonators of whispering gallery mode (WGM) type as optical biosensors mostly integrated with lab-on-a-chip systems. On-chip and microfluidics combined devices along with optical microresonators provide rapid, robust, reproducible and multiplexed biodetection abilities in considerably small volumes. We present a detailed overview of the studies conducted so far, including biodetection of various oligonucleotide biomarkers as well as deoxyribonucleic acids (DNAs), ribonucleic acids (RNAs) and proteins. We particularly advert to chemical surface modifications for specific and selective biosensing.
Collapse
Affiliation(s)
- Pelin Toren
- Institute of Materials Science and Nanotechnology, Bilkent University, 06800 Ankara, Turkey. and UNAM-National Nanotechnology Research Center, Bilkent University, 06800 Ankara, Turkey
| | - Erol Ozgur
- Institute of Materials Science and Nanotechnology, Bilkent University, 06800 Ankara, Turkey. and UNAM-National Nanotechnology Research Center, Bilkent University, 06800 Ankara, Turkey
| | - Mehmet Bayindir
- Institute of Materials Science and Nanotechnology, Bilkent University, 06800 Ankara, Turkey. and UNAM-National Nanotechnology Research Center, Bilkent University, 06800 Ankara, Turkey and Department of Physics, Bilkent University, 06800 Ankara, Turkey
| |
Collapse
|
27
|
Lee JS, Song J, Kim SO, Kim S, Lee W, Jackman JA, Kim D, Cho NJ, Lee J. Multifunctional hydrogel nano-probes for atomic force microscopy. Nat Commun 2016; 7:11566. [PMID: 27199165 PMCID: PMC4876479 DOI: 10.1038/ncomms11566] [Citation(s) in RCA: 17] [Impact Index Per Article: 1.9] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/08/2015] [Accepted: 04/08/2016] [Indexed: 11/10/2022] Open
Abstract
Since the invention of the atomic force microscope (AFM) three decades ago, there have been numerous advances in its measurement capabilities. Curiously, throughout these developments, the fundamental nature of the force-sensing probe-the key actuating element-has remained largely unchanged. It is produced by long-established microfabrication etching strategies and typically composed of silicon-based materials. Here, we report a new class of photopolymerizable hydrogel nano-probes that are produced by bottom-up fabrication with compressible replica moulding. The hydrogel probes demonstrate excellent capabilities for AFM imaging and force measurement applications while enabling programmable, multifunctional capabilities based on compositionally adjustable mechanical properties and facile encapsulation of various nanomaterials. Taken together, the simple, fast and affordable manufacturing route and multifunctional capabilities of hydrogel AFM nano-probes highlight the potential of soft matter mechanical transducers in nanotechnology applications. The fabrication scheme can also be readily utilized to prepare hydrogel cantilevers, including in parallel arrays, for nanomechanical sensor devices.
Collapse
Affiliation(s)
- Jae Seol Lee
- Department of Mechanical Engineering, Sogang University, 35 Baekbeom-ro (Sinsu-dong), Mapo-gu, Seoul 04107, South Korea
| | - Jungki Song
- Department of Mechanical Engineering, Sogang University, 35 Baekbeom-ro (Sinsu-dong), Mapo-gu, Seoul 04107, South Korea
| | - Seong Oh Kim
- School of Materials Science and Engineering and Centre for Biomimetic Sensor Science, Nanyang Technological University, 50 Nanyang Drive, Singapore 637553, Singapore
| | - Seokbeom Kim
- Department of Mechanical Engineering, Sogang University, 35 Baekbeom-ro (Sinsu-dong), Mapo-gu, Seoul 04107, South Korea
| | - Wooju Lee
- Department of Mechanical Engineering, Sogang University, 35 Baekbeom-ro (Sinsu-dong), Mapo-gu, Seoul 04107, South Korea
| | - Joshua A. Jackman
- School of Materials Science and Engineering and Centre for Biomimetic Sensor Science, Nanyang Technological University, 50 Nanyang Drive, Singapore 637553, Singapore
| | - Dongchoul Kim
- Department of Mechanical Engineering, Sogang University, 35 Baekbeom-ro (Sinsu-dong), Mapo-gu, Seoul 04107, South Korea
| | - Nam-Joon Cho
- School of Materials Science and Engineering and Centre for Biomimetic Sensor Science, Nanyang Technological University, 50 Nanyang Drive, Singapore 637553, Singapore
- School of Chemical and Biomedical Engineering, Nanyang Technological University, 62 Nanyang Drive, Singapore 637459, Singapore
| | - Jungchul Lee
- Department of Mechanical Engineering, Sogang University, 35 Baekbeom-ro (Sinsu-dong), Mapo-gu, Seoul 04107, South Korea
| |
Collapse
|
28
|
In-vitro nanodiagnostic platform through nanoparticles and DNA-RNA nanotechnology. Appl Microbiol Biotechnol 2015; 99:3359-74. [PMID: 25761622 DOI: 10.1007/s00253-015-6506-4] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/27/2014] [Revised: 02/20/2015] [Accepted: 02/23/2015] [Indexed: 10/23/2022]
Abstract
Nanocomposites containing nanoparticles or nanostructured domains exhibit an even higher degree of material complexity that leads to an extremely high variability of nanostructured materials. This review introduces analytical concepts and techniques for nanomaterials and derives recommendations for a qualified selection of characterization techniques for specific types of samples, and focuses the characterization of nanoparticles and their agglomerates or aggregates. In addition, DNA nanotechnology and the more recent newcomer RNA nanotechnology have achieved almost an advanced status among nanotechnology researchers¸ therefore, the core features, potential, and significant challenges of DNA nanotechnology are also highlighted as a new discipline. Moreover, nanobiochips made by nanomaterials are rapidly emerging as a new paradigm in the area of large-scale biochemical analysis. The use of nanoscale components enables higher precision in diagnostics while considerably reducing the cost of the platform that leads this review to explore the use of nanoparticles, nanomaterials, and other bionanotechnologies for its application to nanodiagnostics in-vitro.
Collapse
|
29
|
Meier T, Förste A, Tavassolizadeh A, Rott K, Meyners D, Gröger R, Reiss G, Quandt E, Schimmel T, Hölscher H. A scanning probe microscope for magnetoresistive cantilevers utilizing a nested scanner design for large-area scans. BEILSTEIN JOURNAL OF NANOTECHNOLOGY 2015; 6:451-461. [PMID: 25821686 PMCID: PMC4362309 DOI: 10.3762/bjnano.6.46] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 10/10/2014] [Accepted: 01/06/2015] [Indexed: 06/04/2023]
Abstract
We describe an atomic force microscope (AFM) for the characterization of self-sensing tunneling magnetoresistive (TMR) cantilevers. Furthermore, we achieve a large scan-range with a nested scanner design of two independent piezo scanners: a small high resolution scanner with a scan range of 5 × 5 × 5 μm(3) is mounted on a large-area scanner with a scan range of 800 × 800 × 35 μm(3). In order to characterize TMR sensors on AFM cantilevers as deflection sensors, the AFM is equipped with a laser beam deflection setup to measure the deflection of the cantilevers independently. The instrument is based on a commercial AFM controller and capable to perform large-area scanning directly without stitching of images. Images obtained on different samples such as calibration standard, optical grating, EPROM chip, self-assembled monolayers and atomic step-edges of gold demonstrate the high stability of the nested scanner design and the performance of self-sensing TMR cantilevers.
Collapse
Affiliation(s)
- Tobias Meier
- Institute of Microstructure Technology, Karlsruhe Institute of Technology (KIT), Hermann-von-Helmholtz-Platz 1, 76344 Eggenstein-Leopoldshafen, Germany
| | - Alexander Förste
- Institute of Nanotechnology, Karlsruhe Institute of Technology (KIT), Hermann-von-Helmholtz-Platz 1, 76344 Eggenstein-Leopoldshafen, Germany
| | - Ali Tavassolizadeh
- Institute for Materials Science, Christian-Albrechts-Universität zu Kiel, Kaiserstraße 2, 24143 Kiel, Germany
| | - Karsten Rott
- Department of Physics, Bielefeld University, Universitässtraße 25, 33615 Bielefeld, Germany
| | - Dirk Meyners
- Institute for Materials Science, Christian-Albrechts-Universität zu Kiel, Kaiserstraße 2, 24143 Kiel, Germany
| | - Roland Gröger
- Institute of Nanotechnology, Karlsruhe Institute of Technology (KIT), Hermann-von-Helmholtz-Platz 1, 76344 Eggenstein-Leopoldshafen, Germany
| | - Günter Reiss
- Department of Physics, Bielefeld University, Universitässtraße 25, 33615 Bielefeld, Germany
| | - Eckhard Quandt
- Institute for Materials Science, Christian-Albrechts-Universität zu Kiel, Kaiserstraße 2, 24143 Kiel, Germany
| | - Thomas Schimmel
- Institute of Nanotechnology, Karlsruhe Institute of Technology (KIT), Hermann-von-Helmholtz-Platz 1, 76344 Eggenstein-Leopoldshafen, Germany
- Institute of Applied Physics, Karlsruhe Institute of Technology (KIT), Wolfgang-Gaede-Straße 1, 76131 Karlsruhe, Germany
| | - Hendrik Hölscher
- Institute of Microstructure Technology, Karlsruhe Institute of Technology (KIT), Hermann-von-Helmholtz-Platz 1, 76344 Eggenstein-Leopoldshafen, Germany
| |
Collapse
|
30
|
Dias AD, Kingsley DM, Corr DT. Recent advances in bioprinting and applications for biosensing. BIOSENSORS 2014; 4:111-36. [PMID: 25587413 PMCID: PMC4264374 DOI: 10.3390/bios4020111] [Citation(s) in RCA: 61] [Impact Index Per Article: 5.5] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 02/18/2014] [Revised: 04/12/2014] [Accepted: 04/18/2014] [Indexed: 12/19/2022]
Abstract
Future biosensing applications will require high performance, including real-time monitoring of physiological events, incorporation of biosensors into feedback-based devices, detection of toxins, and advanced diagnostics. Such functionality will necessitate biosensors with increased sensitivity, specificity, and throughput, as well as the ability to simultaneously detect multiple analytes. While these demands have yet to be fully realized, recent advances in biofabrication may allow sensors to achieve the high spatial sensitivity required, and bring us closer to achieving devices with these capabilities. To this end, we review recent advances in biofabrication techniques that may enable cutting-edge biosensors. In particular, we focus on bioprinting techniques (e.g., microcontact printing, inkjet printing, and laser direct-write) that may prove pivotal to biosensor fabrication and scaling. Recent biosensors have employed these fabrication techniques with success, and further development may enable higher performance, including multiplexing multiple analytes or cell types within a single biosensor. We also review recent advances in 3D bioprinting, and explore their potential to create biosensors with live cells encapsulated in 3D microenvironments. Such advances in biofabrication will expand biosensor utility and availability, with impact realized in many interdisciplinary fields, as well as in the clinic.
Collapse
Affiliation(s)
- Andrew D Dias
- Department of Biomedical Engineering, Rensselaer Polytechnic Institute, 110 Eighth St., Troy, NY 12180, USA; E-Mails: (A.D.D.); (D.M.K.)
| | - David M Kingsley
- Department of Biomedical Engineering, Rensselaer Polytechnic Institute, 110 Eighth St., Troy, NY 12180, USA; E-Mails: (A.D.D.); (D.M.K.)
| | - David T Corr
- Department of Biomedical Engineering, Rensselaer Polytechnic Institute, 110 Eighth St., Troy, NY 12180, USA; E-Mails: (A.D.D.); (D.M.K.)
| |
Collapse
|
31
|
Steffens C, Leite FL, Manzoli A, Sandoval RD, Fatibello O, Herrmann PSP. Microcantilever sensors coated with doped polyaniline for the detection of water vapor. SCANNING 2014; 36:311-316. [PMID: 23817929 DOI: 10.1002/sca.21109] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 04/01/2013] [Accepted: 05/31/2013] [Indexed: 06/02/2023]
Abstract
In the present work, PANI (polyaniline) emeraldine salt (doped) and base (dedoped) were used as the sensitive layer of a silicon microcantilever, and the mechanical response (deflection) of the bimaterial (coated microcantilever) was investigated under the influence of humidity. PANI in the emeraldine base oxidation state was obtained by interfacial synthesis and was deposited on the microcantilever surface by spin-coating (dedoped). Next, the conducting polymer was doped with 1 M HCl (hydrochloric acid). A four-quadrant AFM head with an integrated laser and a position-sensitive detector (AFM Veeco Dimension V) was used to measure the optical deflection of the coated microcantilever. The deflection of the coated (doped and undoped PANI) and uncoated microcantilever was measured under different humidities (in triplicate) at room pressure and temperature in a closed chamber to evaluate the sensor's sensitivity. The relative humidity (RH) in the chamber was varied from 20% to 70% using dry nitrogen as a carrier gas, which was passed through a bubbler containing water to generate humidity. The results showed that microcantilevers coated with sensitive layers of doped and undoped PANI films were sensitive (12,717 ± 6% and 6,939 ± 8%, respectively) and provided good repeatability (98.6 ± 0.015% and 99 ± 0.01%, respectively) after several cycles of exposure to RH. The microcantilever sensor without a PANI coating (uncoated) was not sensitive to humidity. The strong effect of doping on the sensitivity of the sensor was attributed to an increased adsorption of water molecules dissociated at imine nitrogen centers, which improves the performance of the coated microcantilever sensor. Moreover, microcantilever sensors coated with a sensitive layer provided good results in several cycles of exposure to RH (%).
Collapse
Affiliation(s)
- C Steffens
- Department of Biotechnology, Federal University de São Carlos (UFSCar), SP, Brazil; National Nanotechnology Laboratory for Agribusiness, Embrapa Instrumentation, São Carlos, SP, Brazil
| | | | | | | | | | | |
Collapse
|
32
|
Kaushik A, Kumar R, Huey E, Bhansali S, Nair N, Nanir M. Silica Nanowires: Growth, Integration, and Sensing Applications. Mikrochim Acta 2014; 181:1759-1780. [PMID: 25382871 DOI: 10.1007/s00604-014-1255-0] [Citation(s) in RCA: 34] [Impact Index Per Article: 3.1] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/25/2022]
Abstract
This review (with 129 refs.) gives an overview on how the integration of silica nanowires (NWs) into micro-scale devices has resulted, in recent years, in simple yet robust nano-instrumentation with improved performance in targeted application areas such as sensing. This has been achieved by the use of appropriate techniques such as di-electrophoresis and direct vapor-liquid-growth phenomena, to restrict the growth of NWs to site-specific locations. This also has eliminated the need for post-growth processing and enables nanostructures to be placed on pre-patterned substrates. Various kinds of NWs have been investigated to determine how their physical and chemical properties can be tuned for integration into sensing structures. NWs integrated onto interdigitated micro-electrodes have been applied to the determination of gases and biomarkers. The technique of directly growing NWs eliminates the need for their physical transfer and thus preserves their structure and performance, and further reduces the costs of fabrication. The biocompatibility of NWs also has been studied with respect to possible biological applications. This review addresses the challenges in growth and integration of NWs to understand related mechanism on biological contact or gas exposure and sensing performance for personalized health and environmental monitoring.
Collapse
Affiliation(s)
- Ajeet Kaushik
- Department of Immunology, College of medicine, Florida International University, Miami, FL-33199 USA
| | - Rajesh Kumar
- Bio-MEMS and Microsystems Laboratory, Department of Electrical and Computer Engineering, Florida International University, Miami, FL-33174, USA ; Department of Physics, Panjab University, Chandigarh-160014, India
| | - Eric Huey
- Bio-MEMS and Microsystems Laboratory, Department of Electrical and Computer Engineering, Florida International University, Miami, FL-33174, USA
| | - Shekhar Bhansali
- Bio-MEMS and Microsystems Laboratory, Department of Electrical and Computer Engineering, Florida International University, Miami, FL-33174, USA
| | - Narayana Nair
- Department of Immunology, College of medicine, Florida International University, Miami, FL-33199 USA ; Department of Surgery, Cleveland Clinic, Weston, FL-33331, USA
| | - Madhavan Nanir
- Department of Immunology, College of medicine, Florida International University, Miami, FL-33199 USA
| |
Collapse
|
33
|
Alharbi KK, Al-sheikh YA. Role and implications of nanodiagnostics in the changing trends of clinical diagnosis. Saudi J Biol Sci 2014; 21:109-17. [PMID: 24600302 PMCID: PMC3942856 DOI: 10.1016/j.sjbs.2013.11.001] [Citation(s) in RCA: 25] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/16/2013] [Revised: 11/03/2013] [Accepted: 11/03/2013] [Indexed: 11/18/2022] Open
Abstract
Nanodiagnostics is the term used for the application of nanobiotechnology in molecular diagnosis, which is important for developing personalized cancer therapy. It is usually based on pharmacogenetics, pharmacogenomics, and pharmacoproteomic information but also takes into consideration environmental factors that influence response to therapy. Nanotechnology in medicine involves applications of nanoparticles currently under development, as well as longer range research that involves the use of manufactured nano-robots to make repairs at the cellular level. Nanodiagnostic technologies are also being used to refine the discovery of biomarkers, as nanoparticles offer advantages of high volume/surface ratio and multifunctionality. Biomarkers are important basic components of personalized medicine and are applicable to the management of cancer as well. The field of nano diagnostics raises certain ethical concerns related with the testing of blood. With advances in diagnostic technologies, doctors will be able to give patients complete health checks quickly and routinely. If any medication is required this will be tailored specifically to the individual based on their genetic makeup, thus preventing unwanted side-effects.
Collapse
Affiliation(s)
- Khalid Khalaf Alharbi
- Department of Clinical Laboratory Sciences, College of Applied Medical Sciences, King Saud University, P.O. Box 10219, Riyadh 11433, Saudi Arabia
| | | |
Collapse
|
34
|
Bai X, Hou H, Zhang B, Tang J. Label-free detection of kanamycin using aptamer-based cantilever array sensor. Biosens Bioelectron 2014; 56:112-6. [PMID: 24480130 DOI: 10.1016/j.bios.2013.12.068] [Citation(s) in RCA: 85] [Impact Index Per Article: 7.7] [Reference Citation Analysis] [Abstract] [Key Words] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/22/2013] [Revised: 12/14/2013] [Accepted: 12/31/2013] [Indexed: 11/26/2022]
Abstract
A label-free detection method of kanamycin using aptamer-based cantilever array sensor was developed. The cantilever array was composed of sensing cantilevers and reference cantilevers. This configuration allowed direct detection of individual cantilever deflections and subsequent determination of differential deflection of sensing/reference cantilever pair. The sensing cantilevers were functionalized with kanamycin aptamer, which was used as receptor molecules while the reference cantilevers were modified with 6-mercapto-1-hexanol (MCH) to eliminate the influence of environmental disturbances. The kanamycin-aptamer interaction induced a change in cantilever surface stress, which caused a differential deflection between the sensing and reference cantilever pair. The surface stress change was linear with kanamycin concentration over the range of 100 μM-10mM with a correlation coefficient of 0.995. A detection limit of 50 μM was obtained, at a signal-to-noise ratio of 3. The sensor also showed good selectivity against other antibiotics such as neomycin, ribostamycin and chloramphenicol. The facile method for kanamycin detection may have great potential for investigating more other molecules.
Collapse
Affiliation(s)
- Xiaojing Bai
- State Key Laboratory of Electroanalytical Chemistry, Changchun Institute of Applied Chemistry, Chinese Academy of Sciences, Changchun 130022, PR China; University of Chinese Academy of Sciences, Beijing, 100049, PR China
| | - Hui Hou
- State Key Laboratory of Electroanalytical Chemistry, Changchun Institute of Applied Chemistry, Chinese Academy of Sciences, Changchun 130022, PR China; University of Chinese Academy of Sciences, Beijing, 100049, PR China
| | - Bailin Zhang
- State Key Laboratory of Electroanalytical Chemistry, Changchun Institute of Applied Chemistry, Chinese Academy of Sciences, Changchun 130022, PR China
| | - Jilin Tang
- State Key Laboratory of Electroanalytical Chemistry, Changchun Institute of Applied Chemistry, Chinese Academy of Sciences, Changchun 130022, PR China
| |
Collapse
|
35
|
Huang M, Galarreta BC, Cetin AE, Altug H. Actively transporting virus like analytes with optofluidics for rapid and ultrasensitive biodetection. LAB ON A CHIP 2013; 13:4841-7. [PMID: 24170146 DOI: 10.1039/c3lc50814e] [Citation(s) in RCA: 9] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/11/2023]
Abstract
Effective analyte delivery is essential to achieve rapid and sensitive biodetection systems. In this article, we present an actively controlled fluidic system integrated with a suspended plasmonic nanohole sensor to achieve superior analyte delivery efficiency and ultrafast sensor response, as compared to conventional fluidic systems. 70 nm sized virus like analyte solution is used to experimentally demonstrate the system performance improvements. Sensor response time is reduced by one order of magnitude as compared to the conventional methods. A seven orders of magnitude dynamic concentration range from 10(3) to 10(9) particles mL(-1) is quantified, corresponding to a concentration window relevant to clinical diagnosis and drug screening. Our non-destructive detection system, by enabling efficient analyte delivery, fast sensing response and minimal sample volume, opens up opportunities for sensitive, rapid and real-time virus detection in infectious disease control and point-of-care applications.
Collapse
Affiliation(s)
- Min Huang
- Electrical and Computer Engineering Department, Boston University, Boston, MA, USA
| | | | | | | |
Collapse
|
36
|
Zhang NH, Meng WL, Tan ZQ. A multi-scale model for the analysis of the inhomogeneity of elastic properties of DNA biofilm on microcantilevers. Biomaterials 2013; 34:1833-42. [DOI: 10.1016/j.biomaterials.2012.11.023] [Citation(s) in RCA: 10] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/10/2012] [Accepted: 11/15/2012] [Indexed: 10/27/2022]
|
37
|
Atomic force microscopy as a tool applied to nano/biosensors. SENSORS 2012; 12:8278-300. [PMID: 22969400 PMCID: PMC3436029 DOI: 10.3390/s120608278] [Citation(s) in RCA: 29] [Impact Index Per Article: 2.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 04/05/2012] [Revised: 06/01/2012] [Accepted: 06/05/2012] [Indexed: 11/17/2022]
Abstract
This review article discusses and documents the basic concepts and principles of nano/biosensors. More specifically, we comment on the use of Chemical Force Microscopy (CFM) to study various aspects of architectural and chemical design details of specific molecules and polymers and its influence on the control of chemical interactions between the Atomic Force Microscopy (AFM) tip and the sample. This technique is based on the fabrication of nanomechanical cantilever sensors (NCS) and microcantilever-based biosensors (MC-B), which can provide, depending on the application, rapid, sensitive, simple and low-cost in situ detection. Besides, it can provide high repeatability and reproducibility. Here, we review the applications of CFM through some application examples which should function as methodological questions to understand and transform this tool into a reliable source of data. This section is followed by a description of the theoretical principle and usage of the functionalized NCS and MC-B technique in several fields, such as agriculture, biotechnology and immunoassay. Finally, we hope this review will help the reader to appreciate how important the tools CFM, NCS and MC-B are for characterization and understanding of systems on the atomic scale.
Collapse
|
38
|
|
39
|
SEENA V, FERNANDES AVIL, MUKHERJI SOUMYO, RAO VRAMGOPAL. PHOTOPLASTIC MICROCANTILEVER SENSOR PLATFORM FOR EXPLOSIVE DETECTION. INTERNATIONAL JOURNAL OF NANOSCIENCE 2012. [DOI: 10.1142/s0219581x11008861] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/18/2022]
Abstract
We present an ultrasensitive and cost effective polymeric microcantilever sensor platform for explosive vapor detection. These sensors were fabricated using SU-8 polymer composite materials with two transduction approaches namely (i) optical and (ii) electrical detection. The cantilevers have been characterized for their electrical and mechanical properties. The functionalization of these microcantilevers has been carried out using selective chemicals for most popular explosives such as TNT and RDX. Optical and electrical responses of respective microcantilevers to TNT and RDX vapors are also presented here.
Collapse
Affiliation(s)
- V. SEENA
- Centre for Excellence in Nanoelectronics, Department of Electrical Engineering, Mumbai, Maharashtra, India
| | - AVIL FERNANDES
- Centre for Excellence in Nanoelectronics, Department of Electrical Engineering, Mumbai, Maharashtra, India
| | - SOUMYO MUKHERJI
- Department of Biosceiences and Bio-engineering, Indian Institute of Technology Bombay, Mumbai, Maharashtra, India
| | - V. RAMGOPAL RAO
- Centre for Excellence in Nanoelectronics, Department of Electrical Engineering, Mumbai, Maharashtra, India
| |
Collapse
|
40
|
Spitzer D, Cottineau T, Piazzon N, Josset S, Schnell F, Pronkin SN, Savinova ER, Keller V. Bio-Inspired Nanostructured Sensor for the Detection of Ultralow Concentrations of Explosives. Angew Chem Int Ed Engl 2012; 51:5334-8. [DOI: 10.1002/anie.201108251] [Citation(s) in RCA: 70] [Impact Index Per Article: 5.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/23/2011] [Revised: 03/15/2011] [Indexed: 11/09/2022]
|
41
|
Spitzer D, Cottineau T, Piazzon N, Josset S, Schnell F, Pronkin SN, Savinova ER, Keller V. Ein bioinspirierter nanostrukturierter Sensor für die Detektion von sehr niedrigen Sprengstoffkonzentrationen. Angew Chem Int Ed Engl 2012. [DOI: 10.1002/ange.201108251] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/07/2022]
|
42
|
Punzet M, Baurecht D, Varga F, Karlic H, Heitzinger C. Determination of surface concentrations of individual molecule-layers used in nanoscale biosensors by in situ ATR-FTIR spectroscopy. NANOSCALE 2012; 4:2431-8. [PMID: 22399200 DOI: 10.1039/c2nr12038k] [Citation(s) in RCA: 10] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/26/2023]
Abstract
For the development of nanowire sensors for chemical and medical detection purposes, the optimal functionalization of the surface is a mandatory component. Quantitative ATR-FTIR spectroscopy was used in situ to investigate the step-by-step layer formation of typical functionalization protocols and to determine the respective molecule surface concentrations. BSA, anti-TNF-α and anti-PSA antibodies were bound via 3-(trimethoxy)butylsilyl aldehyde linkers to silicon-oxide surfaces in order to investigate surface functionalization of nanowires. Maximum determined surface concentrations were 7.17 × 10(-13) mol cm(-2) for BSA, 1.7 × 10(-13) mol cm(-2) for anti-TNF-α antibody, 6.1 × 10(-13) mol cm(-2) for anti-PSA antibody, 3.88 × 10(-13) mol cm(-2) for TNF-α and 7.0 × 10(-13) mol cm(-2) for PSA. Furthermore we performed antibody-antigen binding experiments and determined the specific binding ratios. The maximum possible ratio of 2 was obtained at bulk concentrations of the antigen in the μg ml(-1) range for TNF-α and PSA.
Collapse
Affiliation(s)
- Manuel Punzet
- Institute of Biophysical Chemistry, University of Vienna, Althanstrasse 14, A-1090 Vienna, Austria
| | | | | | | | | |
Collapse
|
43
|
Eom K, Jung H, Lee G, Park J, Nam K, Lee SW, Yoon DS, Yang J, Kwon T. Nanomechanical actuation driven by light-induced DNA fuel. Chem Commun (Camb) 2012; 48:955-7. [DOI: 10.1039/c1cc12893k] [Citation(s) in RCA: 16] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/13/2023]
|
44
|
|
45
|
Wu Z, Choudhury K, Griffiths HR, Xu J, Ma X. A novel silicon membrane-based biosensing platform using distributive sensing strategy and artificial neural networks for feature analysis. Biomed Microdevices 2011; 14:83-93. [PMID: 21915644 DOI: 10.1007/s10544-011-9587-6] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/17/2022]
Abstract
A novel biosensing system based on a micromachined rectangular silicon membrane is proposed and investigated in this paper. A distributive sensing scheme is designed to monitor the dynamics of the sensing structure. An artificial neural network is used to process the measured data and to identify cell presence and density. Without specifying any particular bio-application, the investigation is mainly concentrated on the performance testing of this kind of biosensor as a general biosensing platform. The biosensing experiments on the microfabricated membranes involve seeding different cell densities onto the sensing surface of membrane, and measuring the corresponding dynamics information of each tested silicon membrane in the form of a series of frequency response functions (FRFs). All of those experiments are carried out in cell culture medium to simulate a practical working environment. The EA.hy 926 endothelial cell lines are chosen in this paper for the bio-experiments. The EA.hy 926 endothelial cell lines represent a particular class of biological particles that have irregular shapes, non-uniform density and uncertain growth behaviour, which are difficult to monitor using the traditional biosensors. The final predicted results reveal that the methodology of a neural-network based algorithm to perform the feature identification of cells from distributive sensory measurement has great potential in biosensing applications.
Collapse
Affiliation(s)
- Zhangming Wu
- School of Engineering and Applied Science, Aston University, Birmingham, B4 7ET, UK
| | | | | | | | | |
Collapse
|
46
|
Seena V, Fernandes A, Pant P, Mukherji S, Rao VR. Polymer nanocomposite nanomechanical cantilever sensors: material characterization, device development and application in explosive vapour detection. NANOTECHNOLOGY 2011; 22:295501. [PMID: 21673380 DOI: 10.1088/0957-4484/22/29/295501] [Citation(s) in RCA: 15] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/30/2023]
Abstract
This paper reports an optimized and highly sensitive piezoresistive SU-8 nanocomposite microcantilever sensor and its application for detection of explosives in vapour phase. The optimization has been in improving its electrical, mechanical and transduction characteristics. We have achieved a better dispersion of carbon black (CB) in the SU-8/CB nanocomposite piezoresistor and arrived at an optimal range of 8-9 vol% CB concentration by performing a systematic mechanical and electrical characterization of polymer nanocomposites. Mechanical characterization of SU-8/CB nanocomposite thin films was performed using the nanoindentation technique with an appropriate substrate effect analysis. Piezoresistive microcantilevers having an optimum carbon black concentration were fabricated using a design aimed at surface stress measurements with reduced fabrication process complexity. The optimal range of 8-9 vol% CB concentration has resulted in an improved sensitivity, low device variability and low noise level. The resonant frequency and spring constant of the microcantilever were found to be 22 kHz and 0.4 N m(-1) respectively. The devices exhibited a surface stress sensitivity of 7.6 ppm (mN m(-1))(-1) and the noise characterization results support their suitability for biochemical sensing applications. This paper also reports the ability of the sensor in detecting TNT vapour concentration down to less than six parts per billion with a sensitivity of 1 mV/ppb.
Collapse
Affiliation(s)
- V Seena
- Centre for Excellence in Nanoelectronics, Department of Electrical Engineering, Indian Institute of Technology Bombay, Mumbai, Maharashtra, India.
| | | | | | | | | |
Collapse
|
47
|
D'Orazio P. Biosensors in clinical chemistry - 2011 update. Clin Chim Acta 2011; 412:1749-61. [PMID: 21729694 PMCID: PMC7094392 DOI: 10.1016/j.cca.2011.06.025] [Citation(s) in RCA: 131] [Impact Index Per Article: 9.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/11/2011] [Revised: 06/20/2011] [Accepted: 06/21/2011] [Indexed: 12/19/2022]
Abstract
Research activity and applications of biosensors for measurement of analytes of clinical interest over the last eight years are reviewed. Nanotechnology has been applied to improve performance of biosensors using electrochemical, optical, mechanical and physical modes of transduction, and to allow arrays of biosensors to be constructed for parallel sensing. Biosensors have been proposed for measurement of cancer biomarkers, cardiac biomarkers as well as biomarkers for autoimmune disease, infectious disease and for DNA analysis. Novel applications of biosensors include measurements in alternate sample types, such as saliva. Biosensors based on immobilized whole cells have found new applications, for example to detect the presence of cancer and to monitor the response of cancer cells to chemotherapeutic agents. The number of research reports describing new biosensors for analytes of clinical interest continues to increase; however, movement of biosensors from the research laboratory to the clinical laboratory has been slow. The greatest impact of biosensors will be felt at point-of-care testing locations without laboratory support. Integration of biosensors into reliable, easy-to-use and rugged instrumentation will be required to assure success of biosensor-based systems at the point-of-care.
Collapse
Affiliation(s)
- Paul D'Orazio
- Instrumentation Laboratory, Bedford, MA 01730, United States.
| |
Collapse
|
48
|
Pan H, Xu Y, Wu S, Zhang B, Tang J. Molecular interactions in self-assembly monolayers on gold-coated microcantilever electrodes. NANOTECHNOLOGY 2011; 22:225503. [PMID: 21454929 DOI: 10.1088/0957-4484/22/22/225503] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/30/2023]
Abstract
An electrochemical microcantilever (EMC) was used to study the intermolecular interaction of self-assembly monolayers (SAMs) with different n-alkanethiols chain lengths (n = 0, 4, 6, 8, 12, 16) on a Au-coated microcantilever surface. Comparing potential cycling and steps in NaClO(4) solution within the same potential range, the deflection rate of bare microcantilevers is much smaller for the former which revealed that potential excitation, i.e. the surface charge, played the dominant role in driving the instant and large deflection of the bare microcantilever, while the smaller deflection amplitude of the former implied that adsorption of ClO(4)( - ) had an adverse effect on the potential-induced stress. Upon adsorption of SAMs, the deflection amplitude of the microcantilever under the potential step was much smaller than that of a bare microcantilever, and linearly decreased with the chain length increasing for n ≤ 8 (the linear correlation coefficient and the slope are 0.98 and about - 10.4 nm per CH(2) unit, respectively), following a transition (8 ≤ n ≤ 12) to a stable state (n ≥ 12). The decrease of deflection amplitude and faster decay of deflection rate of the SAMs modified microcantilever under the potential step implyed increasing compactness of the SAMs with longer chains.
Collapse
Affiliation(s)
- Hongqing Pan
- State Key Laboratory of Electroanalytical Chemistry, Changchun Institute of Applied Chemistry and Graduate School of Chinese Academy of Sciences, Chinese Academy of Sciences, Changchun, People's Republic of China
| | | | | | | | | |
Collapse
|
49
|
Sriram R, Yadav AR, Mace CR, Miller BL. Validation of arrayed imaging reflectometry biosensor response for protein-antibody interactions: cross-correlation of theory, experiment, and complementary techniques. Anal Chem 2011; 83:3750-7. [PMID: 21517019 PMCID: PMC3102246 DOI: 10.1021/ac2001302] [Citation(s) in RCA: 18] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/29/2022]
Abstract
One of the critical steps in the development of an analytical technique is to confirm that its experimental response correlates with predictions derived from the theoretical framework on which it is based. This validates the technique quantitatively and, in the case of a biosensor, facilitates a correlation of the sensor's output signal to the concentration of the analyte being tested. Herein we report studies demonstrating that the quantitative response of arrayed imaging reflectometry (AIR), a highly sensitive label-free biosensing method, is a predictable function of the probe and analyte properties. We first incorporated a standard one-site Langmuir binding model describing probe-analyte interactions at the surface into the theoretical model for thickness-dependent reflectance in AIR. This established a hypothetical correlation between the analyte concentration and the AIR response. Spectroscopic ellipsometry, surface plasmon resonance, and AIR were then used to validate this model for two biomedically important proteins, fibroblast growth factor-2 and vascular endothelial growth factor. While our studies demonstrated that the 1:1 one-site Langmuir model accurately described the observed response of macrospot AIR arrays, either a two-site Langmuir model or a Sips isotherm better described the behavior of AIR microarrays. These studies confirmed the quantitative performance of AIR across a range of probe-analyte affinities. Furthermore, the methodology developed here can be extended to other label-free biosensing platforms, thus facilitating a more accurate and quantitative interpretation of the sensor response.
Collapse
|
50
|
Sahoo DR, Sebastian A, Häberle W, Pozidis H, Eleftheriou E. Scanning probe microscopy based on magnetoresistive sensing. NANOTECHNOLOGY 2011; 22:145501. [PMID: 21346303 DOI: 10.1088/0957-4484/22/14/145501] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/24/2023]
Abstract
Integrated sensors are essential for scanning probe microscopy (SPM) based systems that employ arrays of microcantilevers for high throughput. Common integrated sensors, such as piezoresistive, piezoelectric, capacitive and thermoelectric sensors, suffer from low bandwidth and/or low resolution. In this paper, a novel magnetoresistive-sensor-based scanning probe microscopy (MR-SPM) technique is presented. The principle of MR-SPM is first demonstrated using experiments with magnetic cantilevers and commercial MR sensors. A new cantilever design tailored to MR-SPM is then presented and micromagnetic simulations are employed to evaluate the achievable resolution. A remarkable resolution of 0.84 Å over a bandwidth of 1 MHz is estimated, which would significantly outperform state-of-the-art optical deflection sensors. Due to its combination of high resolution at high bandwidth, and its amenability to integration in probe arrays, MR-SPM holds great promise for low-cost, high-throughput SPM.
Collapse
Affiliation(s)
- Deepak R Sahoo
- IBM Research-Zurich, Säumerstrasse 4, 8803 Rüschlikon, Switzerland
| | | | | | | | | |
Collapse
|