1
|
Burnet JB, Demeter K, Dorner S, Farnleitner AH, Hammes F, Pinto AJ, Prest EI, Prévost M, Stott R, van Bel N. Automation of on-site microbial water quality monitoring from source to tap: Challenges and perspectives. WATER RESEARCH 2025; 274:123121. [PMID: 39827517 DOI: 10.1016/j.watres.2025.123121] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 09/05/2024] [Revised: 01/01/2025] [Accepted: 01/08/2025] [Indexed: 01/22/2025]
Abstract
Ensuring the provision of safe drinking water necessitates thorough monitoring of microbial water quality. While traditional culture-based enumeration of bacterial indicators has served as the gold standard in compliance monitoring since the late 19th century, recent advancements in microbial sensor technology, driven by automation and digitalization, are revolutionizing on-site monitoring capabilities. These innovations offer unparalleled potential for automated, high temporal frequency monitoring with remote, real-time data transmission. With regulatory frameworks increasingly favouring risk-based approaches to microbial risk management throughout the drinking water supply chain, we are witnessing a paradigm shift towards the adoption of microbial sensors. This review offers a comprehensive examination of the latest developments and accomplishments in automated on-site monitoring of microbial water quality. Beginning with an elucidation of key terminology and an overview of available sensor technologies, we explore how these cutting-edge tools can enhance our understanding of microbial dynamics in the sourcing, treatment, and distribution of drinking water, and how this knowledge can be translated into operational management. Despite the promise of microbial sensors, significant challenges remain. Drawing from insights gathered from an international online survey targeting drinking water utilities, we discuss the analytical, economic, and legal barriers that must be overcome for the implementation of automated on-site monitoring of microbial water quality. This review serves as a vital resource for researchers, utilities, and policymakers operating in water microbiology and sensor technology. While it is addressing drinking water more specifically, the presented concepts and tools can be extrapolated to recreational waters or wastewater management, with the shared goal to ensure sustainable management of water resources and protection of public health.
Collapse
Affiliation(s)
- J B Burnet
- Polytechnique Montreal, Department of Civil, Geological, and Mining Engineering, Polytechnique Montreal, Montreal, Quebec H3C 3A7, Canada; Environmental Research, and Innovation Department, Luxembourg Institute of Science and Technology, Belvaux L-4422, Luxembourg.
| | - K Demeter
- TU Wien, Research Centre ICC Water & Health E057-08 and Research Group Microbiology and Molecular Diagnostics, Vienna 166/5/3, Austria
| | - S Dorner
- Polytechnique Montreal, Department of Civil, Geological, and Mining Engineering, Polytechnique Montreal, Montreal, Quebec H3C 3A7, Canada
| | - A H Farnleitner
- Department Pharmacology, Physiology and Microbiology, Research Division Water Quality and Health, Karl Landsteiner University for Health Sciences, Krems 3500, Austria; TU Wien, Research Centre ICC Water & Health E057-08 and Research Group Microbiology and Molecular Diagnostics, Vienna 166/5/3, Austria
| | - F Hammes
- Department of Environmental Microbiology, Swiss Federal Institute of Aquatic Science and Technology (Eawag), Überland Str. 133, Dübendorf 8600, Switzerland
| | - A J Pinto
- Georgia Institute of Technology, School of Civil and Environmental Engineering, 790, Atlantic Drive, Atlanta, GA, USA
| | - E I Prest
- PWNT, Nieuwe Hemweg 2, Amsterdam, BG 1013, the Netherlands
| | - M Prévost
- Polytechnique Montreal, Department of Civil, Geological, and Mining Engineering, Polytechnique Montreal, Montreal, Quebec H3C 3A7, Canada
| | - R Stott
- National Institute of Water and Atmospheric Research (NIWA) PO Box 11115, Hillcrest, Hamilton 3251, New Zealand
| | - N van Bel
- KWR Water Research Institute, Groningenhaven 7, 3433 PE, Nieuwegein, the Netherlands
| |
Collapse
|
2
|
Shao S, Gao S, Li Y, Lv Y. Rapid Screening and Synthesis of Abiotic Synthetic Receptors for Selective Bacterial Recognition. ACS APPLIED MATERIALS & INTERFACES 2023; 15:16408-16419. [PMID: 36951486 DOI: 10.1021/acsami.2c22438] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/18/2023]
Abstract
The major challenges that impede the preparation of abiotic synthetic receptors designed to feature selective bacterial recognition properties are the complexity, nonrobustness, and environmental adaptability of live microbes. Here, we describe a new rapid screening strategy to determine the optimal polymer formulation on 96-well plates and then produce abiotic synthetic receptors by imprinting the surface marker lipopolysaccharide (LPS) of Gram-negative bacteria. The resulting LPS-imprinted nanoparticles reveal remarkable affinity toward LPS with an equilibrium dissociation constant (KD) value of 10-12 M and can distinguish and selectively recognize specific bacteria in whole blood at concentrations down to 10 cells/mL. The incorporation of gold nanorods into imprinted nanoparticles allows selective microbial inactivation based on photothermal treatment. We have also demonstrated that the imprinted nanoparticles with high affinity for bacteria could induce bacteria clustering, drive the expression of quorum-sensing-controlled signal molecules, and eventually enhance the productivity of the cell factory.
Collapse
Affiliation(s)
- Shengnan Shao
- State Key Laboratory of Organic-Inorganic Composites, National Energy Research and Development Center for Biorefinery, Beijing Key Laboratory of Bioprocess, College of Life Science and Technology, Beijing University of Chemical Technology, Beijing 100029, China
| | - Shuang Gao
- State Key Laboratory of Organic-Inorganic Composites, National Energy Research and Development Center for Biorefinery, Beijing Key Laboratory of Bioprocess, College of Life Science and Technology, Beijing University of Chemical Technology, Beijing 100029, China
| | - Yuan Li
- State Key Laboratory of Organic-Inorganic Composites, National Energy Research and Development Center for Biorefinery, Beijing Key Laboratory of Bioprocess, College of Life Science and Technology, Beijing University of Chemical Technology, Beijing 100029, China
| | - Yongqin Lv
- State Key Laboratory of Organic-Inorganic Composites, National Energy Research and Development Center for Biorefinery, Beijing Key Laboratory of Bioprocess, College of Life Science and Technology, Beijing University of Chemical Technology, Beijing 100029, China
| |
Collapse
|
3
|
Ngashangva L, Hemdan BA, El-Liethy MA, Bachu V, Minteer SD, Goswami P. Emerging Bioanalytical Devices and Platforms for Rapid Detection of Pathogens in Environmental Samples. MICROMACHINES 2022; 13:1083. [PMID: 35888900 PMCID: PMC9321031 DOI: 10.3390/mi13071083] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 06/18/2022] [Revised: 07/04/2022] [Accepted: 07/05/2022] [Indexed: 02/05/2023]
Abstract
The development of robust bioanalytical devices and biosensors for infectious pathogens is progressing well with the advent of new materials, concepts, and technology. The progress is also stepping towards developing high throughput screening technologies that can quickly identify, differentiate, and determine the concentration of harmful pathogens, facilitating the decision-making process for their elimination and therapeutic interventions in large-scale operations. Recently, much effort has been focused on upgrading these analytical devices to an intelligent technological platform by integrating them with modern communication systems, such as the internet of things (IoT) and machine learning (ML), to expand their application horizon. This review outlines the recent development and applications of bioanalytical devices and biosensors to detect pathogenic microbes in environmental samples. First, the nature of the recent outbreaks of pathogenic microbes such as foodborne, waterborne, and airborne pathogens and microbial toxins are discussed to understand the severity of the problems. Next, the discussion focuses on the detection systems chronologically, starting with the conventional methods, advanced techniques, and emerging technologies, such as biosensors and other portable devices and detection platforms for pathogens. Finally, the progress on multiplex assays, wearable devices, and integration of smartphone technologies to facilitate pathogen detection systems for wider applications are highlighted.
Collapse
Affiliation(s)
- Lightson Ngashangva
- Transdisciplinary Biology, Rajiv Gandhi Centre for Biotechnology (RGCB), Thiruvanthapuram, Kerala 695014, India;
| | - Bahaa A. Hemdan
- Department of Biosciences and Bioengineering, Indian Institute of Technology Guwahati, Guwahati, Assam 781039, India; (B.A.H.); (V.B.)
- Water Pollution Research Department, Environmental and Climate Change Research Institute, National Research Centre, 33 El Buhouth Street, Cairo P.O. Box 12622, Egypt;
| | - Mohamed Azab El-Liethy
- Water Pollution Research Department, Environmental and Climate Change Research Institute, National Research Centre, 33 El Buhouth Street, Cairo P.O. Box 12622, Egypt;
| | - Vinay Bachu
- Department of Biosciences and Bioengineering, Indian Institute of Technology Guwahati, Guwahati, Assam 781039, India; (B.A.H.); (V.B.)
| | - Shelley D. Minteer
- Department of Chemistry, University of Utah, 315 South 1400 East, RM 2020, Salt Lake City, UT 84112, USA
| | - Pranab Goswami
- Department of Biosciences and Bioengineering, Indian Institute of Technology Guwahati, Guwahati, Assam 781039, India; (B.A.H.); (V.B.)
| |
Collapse
|
4
|
Liu YS, Deng Y, Chen CK, Khoo BL, Chua SL. Rapid detection of microorganisms in a fish infection microfluidics platform. JOURNAL OF HAZARDOUS MATERIALS 2022; 431:128572. [PMID: 35278965 DOI: 10.1016/j.jhazmat.2022.128572] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 11/24/2021] [Revised: 02/14/2022] [Accepted: 02/23/2022] [Indexed: 06/14/2023]
Abstract
Inadequate access to clean water is detrimental to human health and aquatic industries. Waterborne pathogens can survive prolonged periods in aquatic bodies, infect commercially important seafood, and resist water disinfection, resulting in human infections. Environmental agencies and research laboratories require a relevant, portable, and cost-effective platform to monitor microbial pathogens and assess their risk of infection on a large scale. Advances in microfluidics enable better control and higher precision than traditional culture-based pathogen monitoring approaches. We demonstrated a rapid, high-throughput fish-based teleost (fish)-microbe (TelM) microfluidic-based device that simultaneously monitors waterborne pathogens in contaminated waters and assesses their infection potential under well-defined settings. A chamber-associated port allows direct access to the animal, while the transparency of the TelM platform enables clear observation of sensor readouts. As proof-of-concept, we established a wound infection model using Pseudomonas aeruginosa-contaminated water in the TelM platform, where bacteria formed biofilms on the wound and secreted a biofilm metabolite, pyoverdine. Pyoverdine was used as fluorescent sensor to correlate P. aeruginosa contamination to infection. The TelM platform was validated with environmental waterborne microbes from marine samples. Overall, the TelM platform can be readily applied to assess microbial and chemical risk in aquatic bodies in resource-constrained settings.
Collapse
Affiliation(s)
- Yang Sylvia Liu
- Department of Applied Biology and Chemical Technology, The Hong Kong Polytechnic University, Kowloon, Hong Kong, China
| | - Yanlin Deng
- Department of Biomedical Engineering, City University of Hong Kong, Kowloon, Hong Kong, China
| | - Chun Kwan Chen
- Department of Biomedical Engineering, City University of Hong Kong, Kowloon, Hong Kong, China
| | - Bee Luan Khoo
- Department of Biomedical Engineering, City University of Hong Kong, Kowloon, Hong Kong, China; Hong Kong Center for Cerebro-Cardiovascular Health Engineering (COCHE), Hong Kong, China; City University of Hong Kong - Futian Shenzhen Research Institute, China.
| | - Song Lin Chua
- Department of Applied Biology and Chemical Technology, The Hong Kong Polytechnic University, Kowloon, Hong Kong, China; State Key Laboratory of Chemical Biology and Drug Discovery, The Hong Kong Polytechnic University, Kowloon, Hong Kong, China; Research Centre for Deep Space Explorations, The Hong Kong Polytechnic University, Kowloon, Hong Kong, China; Shenzhen Key Laboratory of Food Biological Safety Control, China.
| |
Collapse
|
5
|
Ewuzie U, Aku NO, Nwankpa SU. An appraisal of data collection, analysis, and reporting adopted for water quality assessment: A case of Nigeria water quality research. Heliyon 2021; 7:e07950. [PMID: 34585001 PMCID: PMC8450204 DOI: 10.1016/j.heliyon.2021.e07950] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/18/2021] [Revised: 08/25/2021] [Accepted: 09/03/2021] [Indexed: 12/27/2022] Open
Abstract
The appropriate acquisition and processing of water quality data are crucial for water resource management. As such, published articles on water quality monitoring and assessment are meant to convey essential and reliable information to water quality experts, decision-makers, researchers, students, and the public. The implication is that such information must emanate from data obtained and analysed in an up-to-date, scientifically sound manner. Thus, inappropriate data analysis and reporting techniques could yield misleading results and mar the endeavours of achieving error-free conclusions. This study utilises the findings on water quality assessment in Nigeria over the last 20 years to reveal the likely trends in water quality research regarding data collection, data analysis, and reporting for physicochemical, bacteriological parameters, and trace organics. A total of 123 Web of Science and quartile ranked (Q1-Q4) published articles involving water quality assessment in Nigeria were analysed. Results indicated shortcomings in various aspects of data analysis and reporting. Consequently, we use simulated heatmaps and graphs to illustrate preferred ways of analysing, reporting, and visualising some regularly used descriptive and inferential statistics of water quality variables. Finally, we highlight alternative approaches to the customarily applied water quality assessment methods in Nigeria and emphasise other areas of deficiency that need attention for improved water quality research.
Collapse
Affiliation(s)
- Ugochukwu Ewuzie
- Analytical/Environmental Unit, Department of Pure and Industrial Chemistry, Abia State University, Nigeria
| | - Nnaemeka O Aku
- Medical Microbiology Unit, Department of Microbiology, University of Nigeria, Nsukka, Nigeria.,Public Health Unit, Department of Community Medicine, University of Nigeria, Enugu Campus, Nigeria
| | - Stephen U Nwankpa
- College of Pharmacy, Roseman University of Health Sciences, South Jordan UT, USA
| |
Collapse
|
6
|
Dar KK, Shao S, Tan T, Lv Y. Molecularly imprinted polymers for the selective recognition of microorganisms. Biotechnol Adv 2020; 45:107640. [DOI: 10.1016/j.biotechadv.2020.107640] [Citation(s) in RCA: 32] [Impact Index Per Article: 6.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/18/2020] [Revised: 09/18/2020] [Accepted: 10/01/2020] [Indexed: 12/20/2022]
|
7
|
Gnaim R, Golberg A, Sheviryov J, Rubinsky B, González CA. Detection and differentiation of bacteria by electrical bioimpedance spectroscopy. Biotechniques 2020; 69:384-394. [PMID: 32486835 DOI: 10.2144/btn-2019-0080] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/23/2022] Open
Abstract
Detecting bacteria in samples and differentiating between Gram-negative and Gram-positive species is an important challenge, and the most common method, Gram staining, is very time consuming. The aim of this study was to evaluate the electrical bioimpedance spectroscopy (EBIS) technique as an inexpensive and practical tool for real-time detection of bacteria and differentiation between Gram-positive and Gram-negative species. The relevant sensitivity for differentiating between species was found in the magnitude and phase at frequencies of 158,489 and 5248 Hz, respectively, at a bacterial concentration of 1 μg/μl. Subsequently, the sensitivity was estimated as a function of bacterial concentration. Our results demonstrated that EBIS can potentially distinguish between presence and absence of bacteria as well as between different types of bacteria.
Collapse
Affiliation(s)
- Rima Gnaim
- Porter School of Environment & Earth Sciences, Tel Aviv University. Tel Aviv-Yafo, Israel.,The Triangle Regional Research & Development Center, Kfar Qari' 30075, Israel
| | - Alexander Golberg
- Porter School of Environment & Earth Sciences, Tel Aviv University. Tel Aviv-Yafo, Israel
| | - Julia Sheviryov
- Porter School of Environment & Earth Sciences, Tel Aviv University. Tel Aviv-Yafo, Israel
| | - Boris Rubinsky
- Mechanical Engineering Department, University of California-Berkeley, CA, USA
| | - César A González
- Porter School of Environment & Earth Sciences, Tel Aviv University. Tel Aviv-Yafo, Israel.,Escuela Superior de Medicina-Instituto Politécnico Nacional, Mexico City, Mexico
| |
Collapse
|
8
|
Setty K, Loret JF, Courtois S, Hammer CC, Hartemann P, Lafforgue M, Litrico X, Manasfi T, Medema G, Shaheen M, Tesson V, Bartram J. Faster and safer: Research priorities in water and health. Int J Hyg Environ Health 2019; 222:593-606. [PMID: 30910612 PMCID: PMC6545151 DOI: 10.1016/j.ijheh.2019.03.003] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/26/2018] [Revised: 03/08/2019] [Accepted: 03/11/2019] [Indexed: 11/22/2022]
Abstract
The United Nations' Sustainable Development Goals initiated in 2016 reiterated the need for safe water and healthy lives across the globe. The tenth anniversary meeting of the International Water and Health Seminar in 2018 brought together experts, students, and practitioners, setting the stage for development of an inclusive and evidence-based research agenda on water and health. Data collection relied on a nominal group technique gathering perceived research priorities as well as underlying drivers and adaptation needs. Under a common driver of public health protection, primary research priorities included the socioeconomy of water, risk assessment and management, and improved monitoring methods and intelligence. Adaptations stemming from these drivers included translating existing knowledge to providing safe and timely services to support the diversity of human water needs. Our findings present a comprehensive agenda of topics at the forefront of water and health research. This information can frame and inform collective efforts of water and health researchers over the coming decades, contributing to improved water services, public health, and socioeconomic outcomes.
Collapse
Affiliation(s)
- Karen Setty
- The Water Institute at University of North Carolina at Chapel Hill, Department of Environmental Sciences and Engineering, 166 Rosenau Hall, CB #7431, Chapel Hill, NC, 27599-7431, USA.
| | - Jean-Francois Loret
- Suez, Centre International de Recherche sur l'Eau et l'Environnement (CIRSEE), 38 rue du President Wilson, 78230, Le Pecq, France.
| | - Sophie Courtois
- Suez, Centre International de Recherche sur l'Eau et l'Environnement (CIRSEE), 38 rue du President Wilson, 78230, Le Pecq, France.
| | - Charlotte Christiane Hammer
- Norwich Medical School, University of East Anglia Faculty of Medicine and Health Sciences, Norwich, NR4 7TJ, UK.
| | - Philippe Hartemann
- Université de Lorraine, Faculté de Médecine, EA 7298, ERAMBO, DESP, Vandœuvre-lès-Nancy, France.
| | - Michel Lafforgue
- Suez Consulting, Le Bruyère 2000 - Bâtiment 1, Zone du Millénaire, 650 Rue Henri Becquerel, CS79542, 34961, Montpellier Cedex 2, France.
| | - Xavier Litrico
- Suez, Tour CB21, 16 Place de l'Iris, 92040, Paris La Defense Cedex, France.
| | - Tarek Manasfi
- Eawag, Swiss Federal Institute of Aquatic Science and Technology, 8600, Dübendorf, Switzerland.
| | - Gertjan Medema
- KWR Watercycle Research Institute, Groningenhaven 7, 3433, PE, Nieuwegein, the Netherlands; Delft University of Technology, Stevinweg 1, 2628 CN, Delft, the Netherlands.
| | - Mohamed Shaheen
- School of Public Health, University of Alberta, 3-300 Edmonton Clinic Health Academy, 11405 - 87 Ave, Edmonton, AB T6G 1C9, Canada.
| | - Vincent Tesson
- French National Institute for Agricultural Research (INRA), UMR 1114 EMMAH, 228 route de l'Aérodrome, CS 40 509, 84914, Avignon Cedex 9, France.
| | - Jamie Bartram
- The Water Institute at University of North Carolina at Chapel Hill, Department of Environmental Sciences and Engineering, 166 Rosenau Hall, CB #7431, Chapel Hill, NC, 27599-7431, USA.
| |
Collapse
|
9
|
Oehler C, Janett F, Schmitt S, Malama E, Bollwein H. Development of a flow cytometric assay to assess the bacterial count in boar semen. Theriogenology 2019; 133:125-134. [PMID: 31091483 DOI: 10.1016/j.theriogenology.2019.04.036] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/23/2018] [Revised: 04/25/2019] [Accepted: 04/30/2019] [Indexed: 01/26/2023]
Abstract
The aim of the study was to develop a new flow cytometric assay for the determination of the bacterial count in commercially processed boar semen. In total 224 fresh boar semen samples collected at an AI-station were analyzed. The number of total viable counts (TVC) was determined by using flow cytometry after staining with SYBR Green I and Propidium Iodide (PI). In the first part of the study 111 fresh boar semen samples were spiked with pure cultures of defined numbers of bacteria commonly detected in boar ejaculates and analyzed by flow cytometry. In the second part, 113 fresh semen samples were assessed on the day of collection through flow cytometry and the Most Probable Number (MPN) method, as the standard bacteriological method. The first part of the study showed a strong correlation between the detected and expected numbers (r = 0.96; P < 0.001), while in the second part of the study the TVC determined by flow cytometry and by the MPN method correlated only moderately (r = 0.28; P < 0.01; median MPN: 24,000 ± MAD 21,600 bacteria/mL; median flow cytometry: 24,426 ± MAD 15,610 bacteria/mL). In summary flow cytometry is a fast alternative to the classical culture technique to determine highly contaminated boar ejaculates. The developed flow cytometric protocol enables one to enumerate the viable bacteria within fresh boar ejaculates without requiring numerous treatment steps, and thus offering the possibility of an on-line use in AI-centers.
Collapse
Affiliation(s)
- Christin Oehler
- Clinic of Reproductive Medicine, Vetsuisse Faculty, University of Zurich, Zurich, Switzerland.
| | - Fredi Janett
- Clinic of Reproductive Medicine, Vetsuisse Faculty, University of Zurich, Zurich, Switzerland
| | - Sarah Schmitt
- Institute of Veterinary Bacteriology, Vetsuisse Faculty, University of Zurich, Zurich, Switzerland
| | - Eleni Malama
- Clinic of Reproductive Medicine, Vetsuisse Faculty, University of Zurich, Zurich, Switzerland
| | - Heinrich Bollwein
- Clinic of Reproductive Medicine, Vetsuisse Faculty, University of Zurich, Zurich, Switzerland
| |
Collapse
|
10
|
Khan BK, Fortunato L, Leiknes T. Early biofouling detection using fluorescence-based extracellular enzyme activity. Enzyme Microb Technol 2019; 120:43-51. [DOI: 10.1016/j.enzmictec.2018.10.001] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/03/2017] [Revised: 09/30/2018] [Accepted: 10/03/2018] [Indexed: 11/28/2022]
|
11
|
Amalfitano S, Levantesi C, Garrelly L, Giacosa D, Bersani F, Rossetti S. Water Quality and Total Microbial Load: A Double-Threshold Identification Procedure Intended for Space Applications. Front Microbiol 2018; 9:2903. [PMID: 30574126 PMCID: PMC6291452 DOI: 10.3389/fmicb.2018.02903] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/06/2018] [Accepted: 11/13/2018] [Indexed: 11/13/2022] Open
Abstract
During longer-lasting future space missions, water renewal by ground-loaded supplies will become increasingly expensive and unmanageable for months. Space exploration by self-sufficient spacecrafts is thus demanding the development of culture-independent microbiological methods for in-flight water monitoring to counteract possible contamination risks. In this study, we aimed at evaluating total microbial load data assessed by selected early-warning techniques with current or promising perspectives for space applications (i.e., HPC, ATP-metry, qPCR, flow cytometry), through the analysis of water sources with constitutively different contamination levels (i.e., chlorinated and unchlorinated tap waters, groundwaters, river waters, wastewaters). Using a data-driven double-threshold identification procedure, we presented new reference values of water quality based on the assessment of the total microbial load. Our approach is suitable to provide an immediate alert of microbial load peaks, thus enhancing the crew responsiveness in case of unexpected events due to water contamination and treatment failure. Finally, the backbone dataset could help in managing water quality and monitoring issues for both space and Earth-based applications.
Collapse
Affiliation(s)
- Stefano Amalfitano
- Water Research Institute – National Research Council of Italy, Monterotondo, Italy
| | - Caterina Levantesi
- Water Research Institute – National Research Council of Italy, Monterotondo, Italy
| | | | - Donatella Giacosa
- Centro Ricerche SMAT, Società Metropolitana Acque Torino S.p.A., Turin, Italy
| | - Francesca Bersani
- Centro Ricerche SMAT, Società Metropolitana Acque Torino S.p.A., Turin, Italy
| | - Simona Rossetti
- Water Research Institute – National Research Council of Italy, Monterotondo, Italy
| |
Collapse
|
12
|
Angelescu D, Huynh V, Hausot A, Yalkin G, Plet V, Mouchel JM, Guérin-Rechdaoui S, Azimi S, Rocher V. Autonomous system for rapid field quantification of Escherichia coli
in surface waters. J Appl Microbiol 2018; 126:332-343. [DOI: 10.1111/jam.14066] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/24/2018] [Revised: 07/15/2018] [Accepted: 08/02/2018] [Indexed: 11/30/2022]
Affiliation(s)
| | - V. Huynh
- Fluidion SAS, R&D Division; Paris France
| | - A. Hausot
- Fluidion SAS, R&D Division; Paris France
| | - G. Yalkin
- Fluidion SAS, R&D Division; Paris France
| | - V. Plet
- Fluidion SAS, R&D Division; Paris France
| | - J.-M. Mouchel
- CNRS, EPHE, UMR 7619 Metis; Sorbonne Université; Paris France
| | | | - S. Azimi
- Direction Innovation Environnement; SIAAP; Colombes France
| | - V. Rocher
- Direction Innovation Environnement; SIAAP; Colombes France
| |
Collapse
|
13
|
Bacteria Detection and Differentiation Using Impedance Flow Cytometry. SENSORS 2018; 18:s18103496. [PMID: 30336557 PMCID: PMC6210208 DOI: 10.3390/s18103496] [Citation(s) in RCA: 55] [Impact Index Per Article: 7.9] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 09/20/2018] [Revised: 10/11/2018] [Accepted: 10/15/2018] [Indexed: 12/01/2022]
Abstract
Monitoring of bacteria concentrations is of great importance in drinking water management. Continuous real-time monitoring enables better microbiological control of the water and helps prevent contaminated water from reaching the households. We have developed a microfluidic sensor with the potential to accurately assess bacteria levels in drinking water in real-time. Multi frequency electrical impedance spectroscopy is used to monitor a liquid sample, while it is continuously passed through the sensor. We investigate three aspects of this sensor: First we show that the sensor is able to differentiate Escherichia coli (Gram-negative) bacteria from solid particles (polystyrene beads) based on an electrical response in the high frequency phase and individually enumerate the two samples. Next, we demonstrate the sensor’s ability to measure the bacteria concentration by comparing the results to those obtained by the traditional CFU counting method. Last, we show the sensor’s potential to distinguish between different bacteria types by detecting different signatures for S. aureus and E. coli mixed in the same sample. Our investigations show that the sensor has the potential to be extremely effective at detecting sudden bacterial contaminations found in drinking water, and eventually also identify them.
Collapse
|
14
|
Jia M, Zhang Z, Li J, Ma X, Chen L, Yang X. Molecular imprinting technology for microorganism analysis. Trends Analyt Chem 2018. [DOI: 10.1016/j.trac.2018.07.011] [Citation(s) in RCA: 89] [Impact Index Per Article: 12.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/09/2023]
|
15
|
Pitkäaho T, Pitkäkangas V, Niemelä M, Rajput SK, Nishchal NK, Naughton TJ. Space-variant video compression and processing in digital holographic microscopy sensor networks with application to potable water monitoring. APPLIED OPTICS 2018; 57:E190-E198. [PMID: 30117884 DOI: 10.1364/ao.57.00e190] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 04/03/2018] [Accepted: 07/04/2018] [Indexed: 06/08/2023]
Abstract
Water-related diseases affect societies in all parts of the world. Online sensors are considered a solution to the problems associated with laboratory testing in potable water. One of the most active research areas of such online sensors has been within optics. Digital holographic microscopy (DHM) has the potential to rival state-of-the-art techniques such as advanced turbidity measurement. However, its use as an online sensor is limited by the large data requirements typical for digital holographic video. In this paper, we provide a solution that permits DHM to be applied to a whole class of online remote sensor networks, of which potable water analysis is one example. The designed sensors incorporate a novel space-variant quantization algorithm to preprocess each frame of a video sequence before transmission over a network. The system satisfies the generally accepted requirements of an online system: automated, near real-time, and operating in a real environment. To verify the effectiveness of the design, we implemented and evaluated it in an active potable water facility.
Collapse
|
16
|
Sorensen JPR, Baker A, Cumberland SA, Lapworth DJ, MacDonald AM, Pedley S, Taylor RG, Ward JST. Real-time detection of faecally contaminated drinking water with tryptophan-like fluorescence: defining threshold values. THE SCIENCE OF THE TOTAL ENVIRONMENT 2018; 622-623:1250-1257. [PMID: 29890592 DOI: 10.1016/j.scitotenv.2017.11.162] [Citation(s) in RCA: 40] [Impact Index Per Article: 5.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 10/19/2017] [Revised: 11/14/2017] [Accepted: 11/15/2017] [Indexed: 06/08/2023]
Abstract
We assess the use of fluorescent dissolved organic matter at excitation-emission wavelengths of 280nm and 360nm, termed tryptophan-like fluorescence (TLF), as an indicator of faecally contaminated drinking water. A significant logistic regression model was developed using TLF as a predictor of thermotolerant coliforms (TTCs) using data from groundwater- and surface water-derived drinking water sources in India, Malawi, South Africa and Zambia. A TLF threshold of 1.3ppb dissolved tryptophan was selected to classify TTC contamination. Validation of the TLF threshold indicated a false-negative error rate of 15% and a false-positive error rate of 18%. The threshold was unsuccessful at classifying contaminated sources containing <10 TTC cfu per 100mL, which we consider the current limit of detection. If only sources above this limit were classified, the false-negative error rate was very low at 4%. TLF intensity was very strongly correlated with TTC concentration (ρs=0.80). A higher threshold of 6.9ppb dissolved tryptophan is proposed to indicate heavily contaminated sources (≥100 TTC cfu per 100mL). Current commercially available fluorimeters are easy-to-use, suitable for use online and in remote environments, require neither reagents nor consumables, and crucially provide an instantaneous reading. TLF measurements are not appreciably impaired by common intereferents, such as pH, turbidity and temperature, within typical natural ranges. The technology is a viable option for the real-time screening of faecally contaminated drinking water globally.
Collapse
Affiliation(s)
| | - Andy Baker
- Connected Waters Initiative Research Centre, UNSW Australia, Sydney, New South Wales 2052, Australia
| | | | - Dan J Lapworth
- British Geological Survey, Maclean Building, Wallingford, OX10 8BB, UK
| | | | - Steve Pedley
- Department of Civil and Environmental Engineering, University of Surrey, Guildford GU2 7XH, UK
| | - Richard G Taylor
- Department of Geography, University College London, London WC1E 6BT, UK
| | - Jade S T Ward
- British Geological Survey, Maclean Building, Wallingford, OX10 8BB, UK; Department of Civil and Environmental Engineering, University of Surrey, Guildford GU2 7XH, UK
| |
Collapse
|
17
|
Savio D, Stadler P, Reischer GH, Kirschner AK, Demeter K, Linke R, Blaschke AP, Sommer R, Szewzyk U, Wilhartitz IC, Mach RL, Stadler H, Farnleitner AH. Opening the black box of spring water microbiology from alpine karst aquifers to support proactive drinking water resource management. WIRES. WATER 2018; 5:e1282. [PMID: 29780584 PMCID: PMC5947618 DOI: 10.1002/wat2.1282] [Citation(s) in RCA: 18] [Impact Index Per Article: 2.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 04/25/2017] [Revised: 01/25/2018] [Accepted: 01/26/2018] [Indexed: 06/08/2023]
Abstract
Over the past 15 years, pioneering interdisciplinary research has been performed on the microbiology of hydrogeologically well-defined alpine karst springs located in the Northern Calcareous Alps (NCA) of Austria. This article gives an overview on these activities and links them to other relevant research. Results from the NCA springs and comparable sites revealed that spring water harbors abundant natural microbial communities even in aquifers with high water residence times and the absence of immediate surface influence. Apparently, hydrogeology has a strong impact on the concentration and size of the observed microbes, and total cell counts (TCC) were suggested as a useful means for spring type classification. Measurement of microbial activities at the NCA springs revealed extremely low microbial growth rates in the base flow component of the studied spring waters and indicated the importance of biofilm-associated microbial activities in sediments and on rock surfaces. Based on genetic analysis, the autochthonous microbial endokarst community (AMEC) versus transient microbial endokarst community (TMEC) concept was proposed for the NCA springs, and further details within this overview article are given to prompt its future evaluation. In this regard, it is well known that during high-discharge situations, surface-associated microbes and nutrients such as from soil habitats or human settlements-potentially containing fecal-associated pathogens as the most critical water-quality hazard-may be rapidly flushed into vulnerable karst aquifers. In this context, a framework for the comprehensive analysis of microbial pollution has been proposed for the NCA springs to support the sustainable management of drinking water safety in accordance with recent World Health Organization guidelines. Near-real-time online water quality monitoring, microbial source tracking (MST) and MST-guided quantitative microbial-risk assessment (QMRA) are examples of the proposed analytical tools. In this context, this overview article also provides a short introduction to recently emerging methodologies in microbiological diagnostics to support reading for the practitioner. Finally, the article highlights future research and development needs. This article is categorized under: 1Engineering Water > Water, Health, and Sanitation2Science of Water > Water Extremes3Water and Life > Nature of Freshwater Ecosystems.
Collapse
Affiliation(s)
- Domenico Savio
- Division Water Quality and HealthDepartment Pharmacology, Physiology and Microbiology, Karl Landsteiner University of Health SciencesKrems a. d. DonauAustria
- Centre for Water Resource SystemsTechnische Universität WienViennaAustria
| | - Philipp Stadler
- Centre for Water Resource SystemsTechnische Universität WienViennaAustria
- Institute for Water Quality, Resource and Waste ManagementTechnische Universität WienViennaAustria
| | - Georg H. Reischer
- Institute of Chemical, Environmental & Bioscience Engineering, Research Group Environmental Microbiology and Molecular Diagnostics166/5/3, Technische Universität WienViennaAustria
- Interuniversity Cooperation Centre for Water and Health, www.waterandhealth.at
| | - Alexander K.T. Kirschner
- Interuniversity Cooperation Centre for Water and Health, www.waterandhealth.at
- Unit Water Hygiene, Institute for Hygiene and Applied ImmunologyMedical University of ViennaViennaAustria
| | - Katalin Demeter
- Centre for Water Resource SystemsTechnische Universität WienViennaAustria
- Institute of Chemical, Environmental & Bioscience Engineering, Research Group Environmental Microbiology and Molecular Diagnostics166/5/3, Technische Universität WienViennaAustria
| | - Rita Linke
- Institute of Chemical, Environmental & Bioscience Engineering, Research Group Environmental Microbiology and Molecular Diagnostics166/5/3, Technische Universität WienViennaAustria
- Interuniversity Cooperation Centre for Water and Health, www.waterandhealth.at
| | - Alfred P. Blaschke
- Centre for Water Resource SystemsTechnische Universität WienViennaAustria
- Interuniversity Cooperation Centre for Water and Health, www.waterandhealth.at
- Institute of Hydraulic Engineering and Water Resources ManagementTechnische Universität WienViennaAustria
| | - Regina Sommer
- Interuniversity Cooperation Centre for Water and Health, www.waterandhealth.at
- Unit Water Hygiene, Institute for Hygiene and Applied ImmunologyMedical University of ViennaViennaAustria
| | - Ulrich Szewzyk
- Department of Environmental TechnologyTechnical University of BerlinBerlinGermany
| | - Inés C. Wilhartitz
- Department of Environmental MicrobiologyEawag, Swiss Federal Institute of Aquatic Science and TechnologyDübendorfSwitzerland
| | - Robert L. Mach
- Institute of Chemical, Environmental & Bioscience Engineering, Research Group Environmental Microbiology and Molecular Diagnostics166/5/3, Technische Universität WienViennaAustria
| | - Hermann Stadler
- Department for Water Resources Management and Environmental AnalyticsInstitute for Water, Energy and Sustainability, Joanneum Research, GrazAustria
| | - Andreas H. Farnleitner
- Division Water Quality and HealthDepartment Pharmacology, Physiology and Microbiology, Karl Landsteiner University of Health SciencesKrems a. d. DonauAustria
- Institute of Chemical, Environmental & Bioscience Engineering, Research Group Environmental Microbiology and Molecular Diagnostics166/5/3, Technische Universität WienViennaAustria
- Interuniversity Cooperation Centre for Water and Health, www.waterandhealth.at
| |
Collapse
|
18
|
Besmer MD, Sigrist JA, Props R, Buysschaert B, Mao G, Boon N, Hammes F. Laboratory-Scale Simulation and Real-Time Tracking of a Microbial Contamination Event and Subsequent Shock-Chlorination in Drinking Water. Front Microbiol 2017; 8:1900. [PMID: 29085343 PMCID: PMC5649192 DOI: 10.3389/fmicb.2017.01900] [Citation(s) in RCA: 18] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/09/2017] [Accepted: 09/15/2017] [Indexed: 12/14/2022] Open
Abstract
Rapid contamination of drinking water in distribution and storage systems can occur due to pressure drop, backflow, cross-connections, accidents, and bio-terrorism. Small volumes of a concentrated contaminant (e.g., wastewater) can contaminate large volumes of water in a very short time with potentially severe negative health impacts. The technical limitations of conventional, cultivation-based microbial detection methods neither allow for timely detection of such contaminations, nor for the real-time monitoring of subsequent emergency remediation measures (e.g., shock-chlorination). Here we applied a newly developed continuous, ultra high-frequency flow cytometry approach to track a rapid pollution event and subsequent disinfection of drinking water in an 80-min laboratory scale simulation. We quantified total (TCC) and intact (ICC) cell concentrations as well as flow cytometric fingerprints in parallel in real-time with two different staining methods. The ingress of wastewater was detectable almost immediately (i.e., after 0.6% volume change), significantly changing TCC, ICC, and the flow cytometric fingerprint. Shock chlorination was rapid and detected in real time, causing membrane damage in the vast majority of bacteria (i.e., drop of ICC from more than 380 cells μl-1 to less than 30 cells μl-1 within 4 min). Both of these effects as well as the final wash-in of fresh tap water followed calculated predictions well. Detailed and highly quantitative tracking of microbial dynamics at very short time scales and for different characteristics (e.g., concentration, membrane integrity) is feasible. This opens up multiple possibilities for targeted investigation of a myriad of bacterial short-term dynamics (e.g., disinfection, growth, detachment, operational changes) both in laboratory-scale research and full-scale system investigations in practice.
Collapse
Affiliation(s)
- Michael D Besmer
- Drinking Water Microbiology Group, Department of Environmental Microbiology, Eawag, Swiss Federal Institute of Aquatic Science and Technology, Dübendorf, Switzerland.,Department of Environmental Systems Science, Institute of Biogeochemistry and Pollutant Dynamics, Zürich, Switzerland
| | - Jürg A Sigrist
- Drinking Water Microbiology Group, Department of Environmental Microbiology, Eawag, Swiss Federal Institute of Aquatic Science and Technology, Dübendorf, Switzerland
| | - Ruben Props
- Center for Microbial Ecology and Technology, Ghent University, Ghent, Belgium
| | | | - Guannan Mao
- Drinking Water Microbiology Group, Department of Environmental Microbiology, Eawag, Swiss Federal Institute of Aquatic Science and Technology, Dübendorf, Switzerland.,Key Laboratory of Pollution Processes and Environmental Criteria (Ministry of Education), Tianjin Key Laboratory of Environmental Remediation and Pollution Control, College of Environmental Science and Engineering, Nankai University, Tianjin, China
| | - Nico Boon
- Center for Microbial Ecology and Technology, Ghent University, Ghent, Belgium
| | - Frederik Hammes
- Drinking Water Microbiology Group, Department of Environmental Microbiology, Eawag, Swiss Federal Institute of Aquatic Science and Technology, Dübendorf, Switzerland
| |
Collapse
|
19
|
Van Nevel S, Koetzsch S, Proctor CR, Besmer MD, Prest EI, Vrouwenvelder JS, Knezev A, Boon N, Hammes F. Flow cytometric bacterial cell counts challenge conventional heterotrophic plate counts for routine microbiological drinking water monitoring. WATER RESEARCH 2017; 113:191-206. [PMID: 28214393 DOI: 10.1016/j.watres.2017.01.065] [Citation(s) in RCA: 118] [Impact Index Per Article: 14.8] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 08/01/2016] [Revised: 01/30/2017] [Accepted: 01/31/2017] [Indexed: 06/06/2023]
Abstract
Drinking water utilities and researchers continue to rely on the century-old heterotrophic plate counts (HPC) method for routine assessment of general microbiological water quality. Bacterial cell counting with flow cytometry (FCM) is one of a number of alternative methods that challenge this status quo and provide an opportunity for improved water quality monitoring. After more than a decade of application in drinking water research, FCM methodology is optimised and established for routine application, supported by a considerable amount of data from multiple full-scale studies. Bacterial cell concentrations obtained by FCM enable quantification of the entire bacterial community instead of the minute fraction of cultivable bacteria detected with HPC (typically < 1% of all bacteria). FCM measurements are reproducible with relative standard deviations below 3% and can be available within 15 min of samples arriving in the laboratory. High throughput sample processing and complete automation are feasible and FCM analysis is arguably less expensive than HPC when measuring more than 15 water samples per day, depending on the laboratory and selected staining procedure(s). Moreover, many studies have shown FCM total (TCC) and intact (ICC) cell concentrations to be reliable and robust process variables, responsive to changes in the bacterial abundance and relevant for characterising and monitoring drinking water treatment and distribution systems. The purpose of this critical review is to initiate a constructive discussion on whether FCM could replace HPC in routine water quality monitoring. We argue that FCM provides a faster, more descriptive and more representative quantification of bacterial abundance in drinking water.
Collapse
Affiliation(s)
- S Van Nevel
- Center for Microbial Ecology and Technology (CMET), Ghent University, Coupure Links 653, B-9000, Gent, Belgium
| | - S Koetzsch
- Eawag, Swiss Federal Institute of Aquatic Science and Technology, Überlandstrasse 133, CH-8600, Dübendorf, Switzerland
| | - C R Proctor
- Eawag, Swiss Federal Institute of Aquatic Science and Technology, Überlandstrasse 133, CH-8600, Dübendorf, Switzerland; Department of Environmental Systems Science, Institute of Biogeochemistry and Pollutant Dynamics, ETH Zürich, Zürich, Switzerland
| | - M D Besmer
- Eawag, Swiss Federal Institute of Aquatic Science and Technology, Überlandstrasse 133, CH-8600, Dübendorf, Switzerland
| | - E I Prest
- Department of Biotechnology, Faculty of Applied Sciences, Delft University of Technology, Van der Maasweg 9, 2629 HZ, Delft, The Netherlands
| | - J S Vrouwenvelder
- Department of Biotechnology, Faculty of Applied Sciences, Delft University of Technology, Van der Maasweg 9, 2629 HZ, Delft, The Netherlands; Wetsus, Centre of Excellence for Sustainable Water Technology, Oostergoweg 9, 8911 MA, Leeuwarden, The Netherlands; King Abdullah University of Science and Technology (KAUST), Water Desalination and Reuse Center (WDRC), Division of Biological and Environmental Science and Engineering (BESE), Thuwal, 23955-6900, Saudi Arabia
| | - A Knezev
- Het Waterlaboratorium, J.W. Lucasweg 2, 2031 BE, Haarlem, The Netherlands
| | - N Boon
- Center for Microbial Ecology and Technology (CMET), Ghent University, Coupure Links 653, B-9000, Gent, Belgium
| | - F Hammes
- Eawag, Swiss Federal Institute of Aquatic Science and Technology, Überlandstrasse 133, CH-8600, Dübendorf, Switzerland.
| |
Collapse
|
20
|
Electrochemical bacterial detection using poly(3-aminophenylboronic acid)-based imprinted polymer. Biosens Bioelectron 2016; 93:87-93. [PMID: 27751788 DOI: 10.1016/j.bios.2016.09.088] [Citation(s) in RCA: 87] [Impact Index Per Article: 9.7] [Reference Citation Analysis] [Abstract] [Key Words] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/01/2016] [Revised: 09/20/2016] [Accepted: 09/24/2016] [Indexed: 01/10/2023]
Abstract
Biosensors can deliver the rapid bacterial detection that is needed in many fields including food safety, clinical diagnostics, biosafety and biosecurity. Whole-cell imprinted polymers have the potential to be applied as recognition elements in biosensors for selective bacterial detection. In this paper, we report on the use of 3-aminophenylboronic acid (3-APBA) for the electrochemical fabrication of a cell-imprinted polymer (CIP). The use of a monomer bearing a boronic acid group, with its ability to specifically interact with cis-diol, allowed the formation of a polymeric network presenting both morphological and chemical recognition abilities. A particularly beneficial feature of the proposed approach is the reversibility of the cis-diol-boronic group complex, which facilitates easy release of the captured bacterial cells and subsequent regeneration of the CIP. Staphylococcus epidermidis was used as the model target bacteria for the CIP and electrochemical impedance spectroscopy (EIS) was explored for the label-free detection of the target bacteria. The modified electrodes showed a linear response over the range of 103-107cfu/mL. A selectivity study also showed that the CIP could discriminate its target from non-target bacteria having similar shape. The CIPs had high affinity and specificity for bacterial detection and provided a switchable interface for easy removal of bacterial cell.
Collapse
|
21
|
Dandapat K, Tripathi SM, Chinifooroshan Y, Bock WJ, Mikulic P. Compact and cost-effective temperature-insensitive bio-sensor based on long-period fiber gratings for accurate detection of E. coli bacteria in water. OPTICS LETTERS 2016; 41:4198-4201. [PMID: 27628356 DOI: 10.1364/ol.41.004198] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/06/2023]
Abstract
We propose and demonstrate a novel temperature-insensitive bio-sensor for accurate and quantitative detection of Escherichia coli (E. coli) bacteria in water. Surface sensitivity is maximized by operating the long-period fiber grating (LPFG) closest to its turnaround wavelength, and the temperature insensitivity is achieved by selectively exciting a pair of cladding modes with opposite dispersion characteristics. Our sensor shows a nominal temperature sensitivity of ∼1.25 pm/°C, which can be further reduced by properly adjusting the LPFG lengths, while maintaining a high refractive index sensitivity of 1929 nm/RIU. The overall length of the sensor is ∼3.6 cm, making it ideally suitable for bio-sensing applications. As an example, we also show the sensor's capability for reliable, quantitative detection of E. coli bacteria in water over a temperature fluctuation of room temperature to 40°C.
Collapse
|
22
|
A novel, optical, on-line bacteria sensor for monitoring drinking water quality. Sci Rep 2016; 6:23935. [PMID: 27040142 PMCID: PMC4819223 DOI: 10.1038/srep23935] [Citation(s) in RCA: 64] [Impact Index Per Article: 7.1] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/01/2015] [Accepted: 03/16/2016] [Indexed: 11/25/2022] Open
Abstract
Today, microbial drinking water quality is monitored through either time-consuming laboratory methods or indirect on-line measurements. Results are thus either delayed or insufficient to support proactive action. A novel, optical, on-line bacteria sensor with a 10-minute time resolution has been developed. The sensor is based on 3D image recognition, and the obtained pictures are analyzed with algorithms considering 59 quantified image parameters. The sensor counts individual suspended particles and classifies them as either bacteria or abiotic particles. The technology is capable of distinguishing and quantifying bacteria and particles in pure and mixed suspensions, and the quantification correlates with total bacterial counts. Several field applications have demonstrated that the technology can monitor changes in the concentration of bacteria, and is thus well suited for rapid detection of critical conditions such as pollution events in drinking water.
Collapse
|
23
|
Mendes Silva D, Domingues L. On the track for an efficient detection of Escherichia coli in water: A review on PCR-based methods. ECOTOXICOLOGY AND ENVIRONMENTAL SAFETY 2015; 113:400-11. [PMID: 25540852 DOI: 10.1016/j.ecoenv.2014.12.015] [Citation(s) in RCA: 57] [Impact Index Per Article: 5.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 07/29/2014] [Revised: 12/03/2014] [Accepted: 12/08/2014] [Indexed: 05/11/2023]
Abstract
Ensuring water safety is an ongoing challenge to public health providers. Assessing the presence of fecal contamination indicators in water is essential to protect public health from diseases caused by waterborne pathogens. For this purpose, the bacteria Escherichia coli has been used as the most reliable indicator of fecal contamination in water. The methods currently in use for monitoring the microbiological safety of water are based on culturing the microorganisms. However, these methods are not the desirable solution to prevent outbreaks as they provide the results with a considerable delay, lacking on specificity and sensitivity. Moreover, viable but non-culturable microorganisms, which may be present as a result of environmental stress or water treatment processes, are not detected by culture-based methods and, thus, may result in false-negative assessments of E. coli in water samples. These limitations may place public health at significant risk, leading to substantial monetary losses in health care and, additionally, in costs related with a reduced productivity in the area affected by the outbreak, and in costs supported by the water quality control departments involved. Molecular methods, particularly polymerase chain reaction-based methods, have been studied as an alternative technology to overcome the current limitations, as they offer the possibility to reduce the assay time, to improve the detection sensitivity and specificity, and to identify multiple targets and pathogens, including new or emerging strains. The variety of techniques and applications available for PCR-based methods has increased considerably and the costs involved have been substantially reduced, which together have contributed to the potential standardization of these techniques. However, they still require further refinement in order to be standardized and applied to the variety of environmental waters and their specific characteristics. The PCR-based methods under development for monitoring the presence of E. coli in water are here discussed. Special emphasis is given to methodologies that avoid pre-enrichment during the water sample preparation process so that the assay time is reduced and the required legislated sensitivity is achieved. The advantages and limitations of these methods are also reviewed, contributing to a more comprehensive overview toward a more conscious research in identifying E. coli in water.
Collapse
Affiliation(s)
- Diana Mendes Silva
- CEB-Centre of Biological Engineering, University of Minho, 4710-057 Braga, Portugal.
| | - Lucília Domingues
- CEB-Centre of Biological Engineering, University of Minho, 4710-057 Braga, Portugal.
| |
Collapse
|
24
|
Liu PY, Chin LK, Ser W, Ayi TC, Yap PH, Bourouina T, Leprince-Wang Y. An optofluidic imaging system to measure the biophysical signature of single waterborne bacteria. LAB ON A CHIP 2014; 14:4237-4243. [PMID: 25205636 DOI: 10.1039/c4lc00783b] [Citation(s) in RCA: 30] [Impact Index Per Article: 2.7] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/03/2023]
Abstract
In this paper, for the first time, an on-chip optofluidic imaging system is innovated to measure the biophysical signatures of single waterborne bacteria, including both their refractive indices and morphologies (size and shape), based on immersion refractometry. The key features of the proposed optofluidic imaging platform include (1) multiple sites for single-bacterium trapping, which enable parallel measurements to achieve higher throughput, and (2) a chaotic micromixer, which enables efficient refractive index variation of the surrounding medium. In the experiments, the distinctive refractive index of Echerichia coli, Shigella flexneri and Vibrio cholera are measured with a high precision of 5 × 10(-3) RIU. The developed optofluidic imaging system has high potential not only for building up a database of biophysical signatures of waterborne bacteria, but also for developing single-bacterium detection in treated water that is in real-time, label-free and low cost.
Collapse
Affiliation(s)
- P Y Liu
- Université Paris-Est, UPEM, F-77454 Marne-la-Vallée, France
| | | | | | | | | | | | | |
Collapse
|
25
|
Wei X, Jie D, Cuello JJ, Johnson DJ, Qiu Z, He Y. Microalgal detection by Raman microspectroscopy. Trends Analyt Chem 2014. [DOI: 10.1016/j.trac.2013.09.012] [Citation(s) in RCA: 20] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/31/2022]
|
26
|
Liu P, Chin L, Ser W, Ayi T, Yap P, Bourouina T, Leprince-Wang Y. Real-time Measurement of Single Bacterium's Refractive Index Using Optofluidic Immersion Refractometry. ACTA ACUST UNITED AC 2014. [DOI: 10.1016/j.proeng.2014.11.743] [Citation(s) in RCA: 30] [Impact Index Per Article: 2.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/26/2022]
|
27
|
Suitability of optical, physical and chemical measurements for detection of changes in bacterial drinking water quality. INTERNATIONAL JOURNAL OF ENVIRONMENTAL RESEARCH AND PUBLIC HEALTH 2013; 10:5349-63. [PMID: 24284353 PMCID: PMC3863849 DOI: 10.3390/ijerph10115349] [Citation(s) in RCA: 15] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 08/28/2013] [Revised: 10/10/2013] [Accepted: 10/13/2013] [Indexed: 11/16/2022]
Abstract
In this study, different optical, physical and chemical measurements were tested for their capacity to detect changes in water quality. The tests included UV-absorbance at 254 nm, absorbance at 420 nm, turbidity, particle counting, temperature, pH, electric conductivity (EC), free chlorine concentration and ATP concentration measurements. Special emphasis was given to investigating the potential for measurement tools to detect changes in bacterial concentrations in drinking water. Bacterial colony counts (CFU) and total bacterial cell counts (TBC) were used as reference methods for assessing the bacterial water quality. The study consists of a series of laboratory scale experiments: monitoring of regrowth of Pseudomonas fluorescens, estimation of the detection limits for optical measurements using Escherichia coli dilutions, verification of the relationships by analysing grab water samples from various distribution systems and utilisation of the measurements in the case of an accidentally contaminated distribution network. We found significant correlations between the tested measurements and the bacterial water quality. As the bacterial contamination of water often co-occurs with the intrusion of matrixes containing mainly non-bacterial components, the tested measurement tools can be considered to have the potential to rapidly detect any major changes in drinking water quality.
Collapse
|