1
|
Cárdenas-Escudero J, Galán-Madruga D, Cáceres JO. Laser-Induced Breakdown Spectroscopy as an Accurate Forensic Tool for Bone Classification and Individual Reassignment. APPLIED SPECTROSCOPY 2025; 79:241-259. [PMID: 39360518 DOI: 10.1177/00037028241277897] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 10/04/2024]
Abstract
This article provides a detailed discussion of the evidence available to date on the application of laser-induced breakdown spectroscopy (LIBS) and supervised classification methods for the individual reassignment of commingled bone remains. Specialized bone chemistry studies have demonstrated the suitability of bone elemental composition as a distinct individual identifier. Given the widely documented ability of the LIBS technique to provide elemental emission spectra that are considered elemental fingerprints of the samples analyzed, the analytical potential of this technique has been assessed for the investigation of the contexts of commingled bone remains for their individual reassignment. The LIBS bone analysis consists of the direct ablation of micrometric portions of bone samples, either on their surface or within their internal structure. To produce reliable, accurate, and robust bone classifications, however, the available evidence suggests that LIBS spectral information must be processed by appropriate methods. When comparing the performance of seven different supervised classification methods using spectrochemical LIBS data for individual reassociation, those employing artificial intelligence-based algorithms produce analytically conclusive results, concretely individual reassociations with 100% accuracy, sensitivity, and robustness. Compared to LIBS, other techniques used for the purpose of interest exhibit limited performance in terms of robustness, sensitivity, and accuracy, as well as variations in these results depending on the type of bones used in the classification. The available literature supports the suitability of the LIBS technique for reliable individual reassociation of bone remains in a fast, simple, and cost-effective manner without the need for complicated sample processing.
Collapse
Affiliation(s)
- Jafet Cárdenas-Escudero
- Laser Chemistry Research Group, Department of Analytical Chemistry, Faculty of Chemistry, Complutense University of Madrid, 28040 Madrid, Spain
- Analytical Chemistry Department, FCNET, Universidad de Panamá, Ciudad Universitaria, Estafeta Universitaria, 3366, Panama City, Panama
| | - David Galán-Madruga
- National Centre for Environmental Health, Carlos III Health Institute, 28220 Majadahonda, Madrid, Spain
| | - Jorge O Cáceres
- Laser Chemistry Research Group, Department of Analytical Chemistry, Faculty of Chemistry, Complutense University of Madrid, 28040 Madrid, Spain
| |
Collapse
|
2
|
Kakuda P, de Souza ID, Covari LF, Tumas V, Queiroz MEC. Cortisol and cortisone determination by disposable pipette extraction (DPX) and ultra-efficient liquid chromatography tandem mass spectrometry (UHPLC-MS/MS) in urine and saliva samples from patients with Parkinson's disease. Anal Bioanal Chem 2024; 416:6589-6600. [PMID: 39327306 DOI: 10.1007/s00216-024-05557-6] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/26/2024] [Revised: 09/12/2024] [Accepted: 09/17/2024] [Indexed: 09/28/2024]
Abstract
Higher serum cortisol levels appear to be associated with stress that can overlap or manifest anxiety, fatigue, depression, and sleep dysfunction. These are common and intrusive non-motor symptoms of Parkinson's disease (PD). Thus, stress has been proposed to mediate Parkinson's disease development, and cortisol has been suggested as a biomarker for the generation of stress-related symptoms in Parkinson's disease. This study describes sensitive and robust disposable pipette extraction (DPX) and ultra-efficient liquid chromatography tandem mass spectrometry (UHPLC-MS/MS) method to determine cortisol and cortisone (as potential endocrine biomarkers for Parkinson's disease) in 24-h urine and saliva samples obtained from Parkinson's disease patients. Important parameters on DPX extraction were optimized to achieve the best extraction recovery and cleanup efficiency. The proposed method was linear from 0.5 (lower limit of quantification) to 500 ng mL-1 for cortisol and from 3.0 (lower limit of quantification) to 500 ng mL-1 for cortisone. To determine whether urinary cortisol and urinary cortisone are adequate as biomarkers to evaluate the level of anxiety in patients suffering from Parkinson's disease, twenty-nine Parkinson's disease patients (18 with anxiety and 11 without anxiety) were selected for urine analysis. Based on the obtained results, 24-h urine samples obtained from Parkinson's disease patients with anxiety had higher cortisone levels than samples obtained from healthy controls. Receiving operating curves (ROC) analysis, which presented the area under the ROC curve (AUC = 0.733), showed that urinary cortisone levels (µg/24-h urine) were sensitive (56.3%) and specific (93.3%) for distinguishing Parkinson's disease patients with anxiety from healthy controls. In terms of salivary results, PD patients' samples taken 30 min after waking up had higher cortisol and cortisone levels than healthy controls, while their samples taken at night had lower cortisol and cortisone levels.
Collapse
Affiliation(s)
- Priscila Kakuda
- Department of Pharmaceutical Sciences, School of Pharmaceutical Sciences of Ribeirão Preto, University of São Paulo, Ribeirão Preto, Brazil
| | - Israel Donizeti de Souza
- Departamento de Química, Faculdade de Filosofia Ciências E Letras de Ribeirão Preto, Universidade de São Paulo, Ribeirão Preto, Brazil
| | - Larissa Fritz Covari
- Departamento de Química, Faculdade de Filosofia Ciências E Letras de Ribeirão Preto, Universidade de São Paulo, Ribeirão Preto, Brazil
| | - Vitor Tumas
- Department of Neuroscience and Behavior, Ribeirão Preto Medical School, University of São Paulo, Ribeirão Preto, Brazil
| | - Maria Eugênia Costa Queiroz
- Department of Pharmaceutical Sciences, School of Pharmaceutical Sciences of Ribeirão Preto, University of São Paulo, Ribeirão Preto, Brazil.
- Departamento de Química, Faculdade de Filosofia Ciências E Letras de Ribeirão Preto, Universidade de São Paulo, Ribeirão Preto, Brazil.
| |
Collapse
|
3
|
Ar-Sanork K, Muekhunthod A, Surapanich N, Chaisuwan P. Simple surface modification of polypropylene pipette tips for anchoring of organic monolithic-based materials for micro-solid-phase extraction. Talanta 2024; 276:126294. [PMID: 38781917 DOI: 10.1016/j.talanta.2024.126294] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/17/2024] [Revised: 05/16/2024] [Accepted: 05/19/2024] [Indexed: 05/25/2024]
Abstract
This paper presents a simple method for the surface modification of polypropylene pipette tips by adsorbing a photo-initiator, 2,2-dimethoxy-2-phenylacetophenone (DMPAP), to create reactive sites for the formation of a layer of ethylene dimethacrylate (EDMA) and subsequent monolith polymerization. The types of monomers and the degree of crosslinking dramatically affected the monolith shrinkage and detachment in unmodified tips. Effective surface modification for anchoring monolithic materials to pipette tips was achieved using 15 wt% DMPAP and 10 wt% EDMA in methanol with UV irradiation at 365 nm. The extraction of 5-hydroxyindoleacetic acid, serotonin, and bisphenol A (BPA) using methacrylate and activated charcoal composite monoliths was investigated in terms of breakthrough capacity. The application of monolithic pipette tip micro-solid-phase extraction followed by HPLC-UV was demonstrated for determining BPA leaching from baby-feeding bottles and canned foods. Wide linearity ranging from 0.1 to 100 ng mL-1 (R2 = 0.9998) with good repeatability (% RSD = 3.9 %) and accuracy (% recovery = 93-106 %) was obtained. The limit of detection and limit of quantification were 0.084 and 0.280 ng mL-1, respectively. By varying the sample loading volume from 0.50 to 10.00 mL with eluting volume of 150 μL, a 2-to-52-fold pre-concentration factor was observed.
Collapse
Affiliation(s)
- Kesara Ar-Sanork
- School of Chemistry, Institute of Science, Suranaree University of Technology, 111 University Avenue, Muang District, Nakhon Ratchasima, 30000, Thailand
| | - Apiwat Muekhunthod
- School of Chemistry, Institute of Science, Suranaree University of Technology, 111 University Avenue, Muang District, Nakhon Ratchasima, 30000, Thailand
| | - Nakin Surapanich
- Department of Chemistry, Faculty of Science and Technology, Rajanagarindra Rajabhat University, 22 Maruphong Road, Tambon Na Mueang, Muang, Chachoengsao, 24000, Thailand
| | - Patcharin Chaisuwan
- School of Chemistry, Institute of Science, Suranaree University of Technology, 111 University Avenue, Muang District, Nakhon Ratchasima, 30000, Thailand.
| |
Collapse
|
4
|
Pour PH, Suzaei FM, Daryanavard SM. Greenness assessment of microextraction techniques in therapeutic drug monitoring. Bioanalysis 2024; 16:249-278. [PMID: 38466891 PMCID: PMC11216521 DOI: 10.4155/bio-2023-0266] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/21/2023] [Accepted: 02/08/2024] [Indexed: 03/13/2024] Open
Abstract
Aim: In this study, we evaluated the greenness and whiteness scores for microextraction techniques used in therapeutic drug monitoring. Additionally, the cons and pros of each evaluated method and their impacts on the provided scores are also discussed. Materials & methods: The Analytical Greenness Sample Preparation metric tool and white analytical chemistry principles are used for related published works (2007-2023). Results & conclusion: This study provided valuable insights for developing methods based on microextraction techniques with a balance in greenness and whiteness areas. Some methods based on a specific technique recorded higher scores, making them suitable candidates as green analytical approaches, and some others achieved high scores both in green and white areas with a satisfactory balance between principles.
Collapse
Affiliation(s)
- Parastoo Hosseini Pour
- Department of Chemistry, Faculty of Science, University of Hormozgan, Bandar-Abbas, 79177, Iran
| | - Foad Mashayekhi Suzaei
- Toxicology Laboratories, Monitoring the Human Hygiene Condition and Standard of Qeshm (MHCS Company), Qeshm Island, 79511, Iran
| | | |
Collapse
|
5
|
Samadifar M, Yamini Y, Khataei MM, Shirani M. Automated and semi-automated packed sorbent solid phase (micro) extraction methods for extraction of organic and inorganic pollutants. J Chromatogr A 2023; 1706:464227. [PMID: 37506462 DOI: 10.1016/j.chroma.2023.464227] [Citation(s) in RCA: 6] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/04/2023] [Revised: 07/06/2023] [Accepted: 07/19/2023] [Indexed: 07/30/2023]
Abstract
In this study, the packed sorbent solid phase (micro) extraction methods from manual to automated modes are reviewed. The automatic methods have several remarkable advantages such as high sample throughput, reproducibility, sensitivity, and extraction efficiency. These methods include solid-phase extraction, pipette tip micro-solid phase extraction, microextraction by packed sorbent, in-tip solid phase microextraction, in-tube solid phase microextraction, lab-on-a-chip, and lab-on-a-valve. The recent application of these methods for the extraction of organic and inorganic compounds are discussed. Also, the combination of novel technologies (3D printing and robotic platforms) with the (semi)automated methods are investigated as the future trend.
Collapse
Affiliation(s)
- Mahsa Samadifar
- Department of Chemistry, Faculty of Sciences, Tarbiat Modares University, Tehran, Iran
| | - Yadollah Yamini
- Department of Chemistry, Faculty of Sciences, Tarbiat Modares University, Tehran, Iran.
| | | | - Mahboue Shirani
- Department of Chemistry, Faculty of Sciences, University of Jiroft, Jiroft, Iran
| |
Collapse
|
6
|
Gurrani S, Prakasham K, Huang PC, Wu MT, Wu CF, Lin YC, Tsai B, Krishnan A, Tsai PC, Ponnusamy VK. Simultaneous biomonitoring of volatile organic compounds' metabolites in human urine samples using a novel in-syringe based fast urinary metabolites extraction (FaUMEx) technique coupled with UHPLC-MS/MS analysis. CHEMOSPHERE 2023; 329:138667. [PMID: 37059207 DOI: 10.1016/j.chemosphere.2023.138667] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 02/04/2023] [Revised: 03/31/2023] [Accepted: 04/10/2023] [Indexed: 05/03/2023]
Abstract
Assessing the impact of human exposure to environmental toxicants is often crucial to biomonitoring the exposed dose. In this work, we report a novel fast urinary metabolites extraction (FaUMEx) technique coupled with UHPLC-MS/MS analysis for the highly sensitive and simultaneous biomonitoring of the five major urinary metabolites (thiodiglycolic acid, s-phenylmercapturic acid, t,t-muconic acid, mandelic acid, and phenyl glyoxylic acid) of common volatile organic compounds' (VOCs) exposure (vinyl chloride, benzene, styrene, and ethylbenzene) in human. FaUMEx technique comprises of two-steps, liquid-liquid microextraction was performed first in an extraction syringe using 1 mL of methanol (pH 3) as an extraction solvent and then, the extractant was passed through a clean-up syringe (pre-packed-with various sorbents including 500 mg anhydrous MgSO4, 50 mg C18, and 50 mg SiO2) to obtain the high order of matrice clean-up and preconcentration efficiency. The developed method displayed excellent linearity, and the correlation coefficients were >0.998 for all the target metabolites with detection and quantification limits of 0.02-0.24 ng mL-1 and 0.05-0.72 ng mL-1, respectively. Furthermore, the matrix effects were < ±5%, and inter and intra-day precision were <9%. Moreover, the presented method was applied and validated to real sample analysis for biomonitoring of VOC's exposure levels. The results showed that the developed FaUMEx-UHPLC-MS/MS method is fast, simple, low-cost, low-solvent consumption, high sensitivity with good accuracy and precision for five targeted urinary VOCs' metabolites. Therefore, the presented dual-syringe mode FaUMEx strategy with UHPLC-MS/MS technique can be applied to biomonitoring of various urinary metabolites to assess human exposure to environmental toxicants.
Collapse
Affiliation(s)
- Swapnil Gurrani
- PhD Program in Environmental and Occupational Medicine, College of Medicine, Kaohsiung Medical University (KMU), Kaohsiung City, 807, Taiwan
| | - Karthikeyan Prakasham
- PhD Program in Environmental and Occupational Medicine, College of Medicine, Kaohsiung Medical University (KMU), Kaohsiung City, 807, Taiwan
| | - Po-Chin Huang
- National Institute of Environmental Health Sciences, National Health Research Institutes (NHRI), Miaoli County, 35053, Taiwan; Department of Medical Research, China Medical University Hospital, China Medical University, Taichung City, Taiwan; Research Center for Precision Environmental Medicine, Kaohsiung Medical University (KMU), Kaohsiung City, 807, Taiwan
| | - Ming-Tsang Wu
- Research Center for Precision Environmental Medicine, Kaohsiung Medical University (KMU), Kaohsiung City, 807, Taiwan; Department of Public Health, Kaohsiung Medical University, Kaohsiung City, Taiwan
| | - Chia-Fang Wu
- Research Center for Precision Environmental Medicine, Kaohsiung Medical University (KMU), Kaohsiung City, 807, Taiwan; International Master Program of Translational Medicine, College of Engineering and Science, National United University, Miaoli, Taiwan
| | - Yu-Chia Lin
- Research and Development Division, Great Engineering Technology (GETECH) Corporation, No.392, Yucheng Rd., Zuoying District., Kaohsiung City, 813, Taiwan
| | - Bongee Tsai
- Research and Development Division, Great Engineering Technology (GETECH) Corporation, No.392, Yucheng Rd., Zuoying District., Kaohsiung City, 813, Taiwan
| | - Anbarasu Krishnan
- Department of Computational Biology, Institute of Bioinformatics, Saveetha School of Engineering, Saveetha Institute of Medical and Technical Sciences, Saveetha University, Chennai, 602105, India
| | - Pei-Chien Tsai
- Department of Computational Biology, Institute of Bioinformatics, Saveetha School of Engineering, Saveetha Institute of Medical and Technical Sciences, Saveetha University, Chennai, 602105, India; Department of Medicinal and Applied Chemistry, Kaohsiung Medical University (KMU), Kaohsiung City, 807, Taiwan
| | - Vinoth Kumar Ponnusamy
- PhD Program in Environmental and Occupational Medicine, College of Medicine, Kaohsiung Medical University (KMU), Kaohsiung City, 807, Taiwan; Research Center for Precision Environmental Medicine, Kaohsiung Medical University (KMU), Kaohsiung City, 807, Taiwan; Department of Medicinal and Applied Chemistry, Kaohsiung Medical University (KMU), Kaohsiung City, 807, Taiwan; Department of Medical Research, Kaohsiung Medical University Hospital (KMUH), Kaohsiung City, 807, Taiwan.
| |
Collapse
|
7
|
Suwanvecho C, Krčmová LK, Švec F. Effective, convenient, and green sample preparation for the determination of retinol and retinol acetate in human serum using pipette tip microextraction. Talanta 2023; 262:124689. [PMID: 37220691 DOI: 10.1016/j.talanta.2023.124689] [Citation(s) in RCA: 6] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/06/2023] [Revised: 05/04/2023] [Accepted: 05/17/2023] [Indexed: 05/25/2023]
Abstract
An efficient sample preparation based on pipette tip microextraction that can be used for the analysis of retinol in human serum has been developed. Altogether, nine commercial pipette tips were compared based on recovery, sample volume, use of organic solvent, handling difficulty, duration of the preparation process, price, and greenness of the method. Retinol acetate was used as the internal standard. The extraction efficiency for both compounds was evaluated to optimize and select the best pipette tip for sample preparation, which was the WAX-S XTR pipette tip containing an ion exchanger and salt. This tip combined solid phase extraction and salting-out assisted liquid‒liquid extraction. Satisfying recoveries of 100 and 80% for retinol and retinol acetate, respectively, and good repeatability were demonstrated. The action of this pipette tip was based on the clean-up workflow in which the interferences were retained on the sorbent. The presence of residual interferences in the extracted samples did not affect the HPLC separation of compounds of interest. The simplicity of the clean-up workflow reduced the time of the sample preparation compared to the bind-wash-elute counterpart workflow. The advantages of our technique are its environmental friendliness and cost effectiveness. The selected pipette tip with an excellent microextraction efficiency enables sample preparation in both clinical research and practice.
Collapse
Affiliation(s)
- Chaweewan Suwanvecho
- The Department of Analytical Chemistry, Faculty of Pharmacy in Hradec Králové, Charles University, Akademika Heyrovského 1203, 500 05, Hradec Králové, Czech Republic; The Department of Clinical Biochemistry and Diagnostics, University Hospital Hradec Králové, Sokolská 581, 500 05, Hradec Králové, Czech Republic
| | - Lenka Kujovská Krčmová
- The Department of Analytical Chemistry, Faculty of Pharmacy in Hradec Králové, Charles University, Akademika Heyrovského 1203, 500 05, Hradec Králové, Czech Republic; The Department of Clinical Biochemistry and Diagnostics, University Hospital Hradec Králové, Sokolská 581, 500 05, Hradec Králové, Czech Republic.
| | - František Švec
- The Department of Analytical Chemistry, Faculty of Pharmacy in Hradec Králové, Charles University, Akademika Heyrovského 1203, 500 05, Hradec Králové, Czech Republic
| |
Collapse
|
8
|
Yamamoto S, Kato N, Wada M, Kinoshita M. A rapid and convenient enzyme digestion method for the analysis of N-glycans using exoglycosidase-impregnated polyacrylamide gels fabricated in an automatic pipette tip. ANAL SCI 2023:10.1007/s44211-023-00314-8. [PMID: 36917436 DOI: 10.1007/s44211-023-00314-8] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/03/2023] [Accepted: 03/01/2023] [Indexed: 03/16/2023]
Abstract
Efficient enzymatic digestion methods are critical for the characterization and identification of glycans. Glycan hydrolysis enzymes are widely utilized for the identification of glycoprotein or glycolipid glycans. The commonly utilized in solution glycan hydrolysis methods require several hours of incubation with enzymes for complete removal of their target monosaccharides. To develop an efficient and simple method for the rapid release of monosaccharides from glycoprotein glycans, we fabricated exoglycosidase-impregnated acrylamide gels in an automatic pipette tip. Our automated enzymatic reactors are based on the simple photochemical copolymerization of monomers comprising acrylamide and methylene-bis-acrylamide-containing enzymes with an azobis compound functioning as the photocatalytic initiator. After filling the tip of the automatic pipette with these acrylamide solutions, polymerization of the acrylamide gel solution was performed by irradiation with a LED. The immobilized enzymes maintained their activities in the pipette tips and their action was completed by fully automatic pipetting for 10 to 30 min. We utilized 8-aminopyrene-1, 3, 6-trisulfonic acid (APTS)-labeled glycans as a substrate and measured by capillary electrophoresis (CE) before and after enzymatic digestion. We demonstrated that this method exhibited quantitative enzymatic and specific cleavage of monosaccharides from glycoprotein glycans.
Collapse
Affiliation(s)
- Sachio Yamamoto
- Faculty of Pharmaceutical Sciences, Kindai University, 3-4-1, Kowakae, Higashi-osaka, Osaka, 577-8502, Japan.
| | - Naho Kato
- Faculty of Pharmaceutical Sciences, Kindai University, 3-4-1, Kowakae, Higashi-osaka, Osaka, 577-8502, Japan
| | - Miki Wada
- Faculty of Pharmaceutical Sciences, Kindai University, 3-4-1, Kowakae, Higashi-osaka, Osaka, 577-8502, Japan
| | - Mitsuhiro Kinoshita
- Faculty of Pharmaceutical Sciences, Kindai University, 3-4-1, Kowakae, Higashi-osaka, Osaka, 577-8502, Japan.,Antiaging Center, Kindai University, 3-4-1, Kowakae, Higashi-osaka, Osaka, 577-8502, Japan
| |
Collapse
|
9
|
Ullah N, Tuzen M. A New Trend and Future Perspectives of the Miniaturization of Conventional Extraction Methods for Elemental Analysis in Different Real Samples: A Review. Crit Rev Anal Chem 2022; 54:1729-1747. [PMID: 36197714 DOI: 10.1080/10408347.2022.2128635] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/10/2022]
Abstract
Sample preparation is one of the viable procedures to be used before analysis to enhance sensitivity and reduce the matrix effect. The current review is mainly emphasized the latest outcome and applications of microextraction techniques based on the miniaturization of the classical conventional methods based on liquid-phase and solid-phase extraction for the quantitative elemental analysis in different real samples. The limitation of the conventional sample preparation methods (liquid and solid phase extraction) has been overcome by developing a new way of reducing size as compared with the conventional system through the miniaturization approach. Miniaturization of the sample preparation techniques has received extensive attention due to its extraction at microlevels, speedy, economical, eco-friendly, and high extraction capability. The growing demand for speedy, economically feasible, and environmentally sound analytical approaches is the main intention to upgrade the conventional procedures apply for sample preparation in environmental investigation. A growing trend of research has been perceived to quantify the trace for elemental analysis in different natures of real samples. This review also recapitulates the current futuristic scenarios for the green and economically viable procedure with special overemphasis and concentrates on eco-friendly miniaturized sample-preparation techniques such as liquid-phase microextraction (LPME) and solid-phase microextraction (SPME). This review also emphasizes the latest progress and applications of the LPME and SPME approach and their future perspective.
Collapse
Affiliation(s)
- Naeem Ullah
- Faculty of Science and Arts, Chemistry Department, Tokat Gaziosmanpaşa University, Tokat, Turkey
- Department of Chemistry, University of Turbat, Balochistan, Pakistan
| | - Mustafa Tuzen
- Faculty of Science and Arts, Chemistry Department, Tokat Gaziosmanpaşa University, Tokat, Turkey
- Research Institute, Center for Environment and Marine Studies, King Fahd University of Petroleum and Minerals, Dhahran, Saudi Arabia
| |
Collapse
|
10
|
Homemade Pipette Tip Solid-Phase Extraction for the Simultaneous Determination of 40 Drugs of Abuse in Urine by Liquid Chromatography–Tandem Mass Spectrometry. SEPARATIONS 2022. [DOI: 10.3390/separations9090233] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/16/2022] Open
Abstract
Pipette tip solid-phase extraction facilitates the handling of low-volume samples and organic solvents in order to achieve more environmentally friendly pre-treatment sample techniques. The use of pipette tip extraction was examined for the quick and simple determination of a heterogeneous group of 40 drugs of abuse and some of their metabolites in urine by liquid chromatography coupled to tandem mass spectrometry. Several parameters were studied and optimized, including those which can affect extraction efficiencies, such as the amount of sorbent and the volumes and number of aspirating/dispensing cycles of the sample and organic solvents. The linear range of this method was between the quantification limit and 75 or 100 ng mL−1. Detection limits between 0.025 and 0.500 ng mL−1 and quantification limits from 0.100 to 1.500 ng mL−1 were achieved, which are adequate to determine the studied compounds in urine from drug users. Finally, in order to prove its suitability in toxicological and forensic analyses, the method was successfully applied to 22 urine specimens from women who were starting a detoxification program. Cocaine was the most frequently detected substance, as its presence or the presence of its main metabolite was found in 86% of the analyzed samples.
Collapse
|
11
|
Wang Q, Wang T, Zhang Y, Ma J, Tuo Y. Preparation and evaluation of a chitosan modified biochar as an efficient adsorbent for pipette tip-solid phase extraction of triazine herbicides from rice. Food Chem 2022; 396:133716. [PMID: 35870243 DOI: 10.1016/j.foodchem.2022.133716] [Citation(s) in RCA: 11] [Impact Index Per Article: 3.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/21/2022] [Revised: 06/19/2022] [Accepted: 07/13/2022] [Indexed: 02/06/2023]
Abstract
The low allowable limit of triazine herbicides (THs) in rice makes it imperative to develop novel sample pretreatment methods for extraction and preconcentration of THs. Herein, a phosphoric acid activated biochar (PBC) was prepared and modified by chitosan (CS). For THs with different polarities, CS-PBC with multiple interaction sites exhibited satisfactory chemisorption. On this basis, a CS-PBC-based pipette tip-solid phase extraction (PT-SPE) was developed combined with HPLC to extract THs from rice. Low limits of detection (1.41-3.35 ng g-1), satisfactory linearity (0.01-2.00 μg g-1, R2 > 0.9974) and recoveries (96.13-116.25 %) were obtained with acceptable inter-day and intra-day precision (RSD ≤ 13.60 %). CS-PBC showed superior performance to three commercial single-mode adsorbents and comparable results to a hydrophilic-lipophilic balance adsorbent. The study explored the feasibility of PT-SPE for extracting THs from rice and broadened the application of plant biochar as an environmentally-friendly matrix in food sample pretreatment.
Collapse
Affiliation(s)
- Qing Wang
- College of Biotechnology and Food Science, Tianjin University of Commerce, Tianjin 300134, China; Tianjin Key Laboratory of Food Biotechnology, Tianjin 300134, China.
| | - Tingting Wang
- College of Biotechnology and Food Science, Tianjin University of Commerce, Tianjin 300134, China
| | - Yanqing Zhang
- College of Biotechnology and Food Science, Tianjin University of Commerce, Tianjin 300134, China; Tianjin Key Laboratory of Food Biotechnology, Tianjin 300134, China.
| | - Jiaxing Ma
- College of Biotechnology and Food Science, Tianjin University of Commerce, Tianjin 300134, China
| | - Yiqian Tuo
- College of Biotechnology and Food Science, Tianjin University of Commerce, Tianjin 300134, China
| |
Collapse
|
12
|
Salt-Induced Homogeneous Liquid–Liquid Microextraction of Piroxicam and Meloxicam from Human Urine Prior to Their Determination by HPLC-DAD. APPLIED SCIENCES-BASEL 2022. [DOI: 10.3390/app12136658] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/17/2022]
Abstract
A salt-induced homogeneous liquid–liquid microextraction (SI-HLLME) protocol combined with high-performance liquid chromatography–diode array detection is presented for the first time for the determination of piroxicam and meloxicam in human urine. The main parameters affecting the performance of the sample preparation protocol were optimized by means of a two-step experimental design (i.e., 2-level fractional factorial design and Box–Behnken design). Following its optimization, the proposed method was thoroughly validated in terms of the total error concept in order to take into consideration the random and systematic errors. For the target analytes, accuracy profiles were constructed, and they were used as graphical decision-making tools. In all cases, the β-expectation tolerance intervals complied with the acceptance criteria of ±15%, proving that 95% of future results will fall within the defined bias limits. The limits of detection were 0.02 μg mL−1 and 0.03 μg mL−1 for piroxicam and meloxicam, respectively. The relative standard deviations were lower than 4.4% in all cases, and the mean relative biases ranged between −5.7 and 3.4% for both drugs. The proposed scheme is simple and rapid, while it is characterized by high sample throughput. Moreover, SI-HLLME requires reduced sample and reagent consumption, according to the requirements of Green Analytical Chemistry.
Collapse
|
13
|
Development of sol-gel silica-based mixed-mode zwitterionic sorbents for determining drugs in environmental water samples. J Chromatogr A 2022; 1676:463237. [PMID: 35752147 DOI: 10.1016/j.chroma.2022.463237] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/31/2022] [Revised: 06/10/2022] [Accepted: 06/10/2022] [Indexed: 11/23/2022]
Abstract
Four novel mixed-mode zwitterionic silica-based functionalized with strong moieties sorbents were synthesized and evaluated through solid-phase extraction (SPE) to determine acidic and basic drugs in environmental water samples. All sorbents had the same functionalization: quaternary amine and sulfonic groups and C18 chains so that hydrophobic and strong cationic exchange (SCX) and strong anionic exchange (SAX) interactions could be exploited, in addition, two of them had carbon microparticles embedded. All sorbents retained both acidic and basic compounds in the preliminary assays but only the basic compounds were retained selectively through ionic exchange interactions when a clean-up step was introduced. The SPE method was therefore optimized to promote the selective retention of the basic compounds, initially with the two best-performing sorbents. After optimization of the SPE protocol, these sorbents were evaluated for the analysis of environmental water samples using liquid chromatography-tandem mass spectrometry (LC-MS/MS). The method with the best-performing sorbent was then validated with 100 mL of river samples and 50 mL of effluent wastewater samples in terms of apparent recoveries (%Rapp) spiking samples at 50 ng/L (river) and 200 ng/L (river and effluent), matrix effect, linear range, method quantification and detection limits, repeatability, and reproducibility. It should be highlighted that %Rapp ranged from 40 to 85% and matrix effects ranged from -17 to -4% for spiked river samples. When the method was applied to river and effluent wastewater samples, most compounds were found in the range from 24 to 1233 ng/L with detection limits from 1 to 5 ng/L.
Collapse
|
14
|
Tamandani M, Hashemi SH, Kaykhaii M, Jamali Keikha A, Nasiriyan A. Determination of profenofos in seawater and foodstuff samples after its molecularly imprinted polymer pipette-tip micro solid phase extraction optimized by response surface methodology. BMC Chem 2022; 16:12. [PMID: 35292077 PMCID: PMC8922791 DOI: 10.1186/s13065-022-00807-z] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/27/2021] [Accepted: 03/07/2022] [Indexed: 11/20/2022] Open
Abstract
Background In this research, a molecularly imprinted polymer (MIP) was synthesized and employed as a sorbent for pipette-tip micro solid phase extraction of profenofos insecticide in seawater, rice, and fish samples. The instrument employed for quantitation was spectrophotometry. Results Various factors affecting the microextraction protocol, including type and volume of the elution solvent, weight of MIP, pH and volume of sample solution, and number of cycles of loading and desorption were considered and optimized using one-factor-at-a-time, central composite design and Box-Behnken design. Factors optimized at: pH 4.0, amount of sorbent 2.5 mg, volume of methanol:acetic (9:1) acid as eluent 250 µL, both the number of extraction and elution cycles 5, and volume of sample 8.0 mL. At optimized conditions, an enrichment factor of 31 was achieved and the linearity range of the method was between 1.0 and 1000.0 µg/L. A good detection limit of 0.33 µg/L with a reproducibility better than 5.6% (as RSD) was observed. Conclusion The technique showed good analytical features for determination of profenofos in seawater, rice, and fish samples. Simplicity of operation of spectrophotometry and lack of using expensive HPLC grade solvents are other points of strengths of this method. The total analysis time was about 10 min, which is far less than techniques such as HPLC. Comparison between optimization with central composite design and Box–Behnken design showed better performance of the former. Supplementary Information The online version contains supplementary material available at 10.1186/s13065-022-00807-z.
Collapse
Affiliation(s)
- Mahsa Tamandani
- Department of Marine Chemistry, Faculty of Marine Science, Chabahar Maritime University, Chabahar, Iran
| | - Sayyed Hossein Hashemi
- Department of Marine Chemistry, Faculty of Marine Science, Chabahar Maritime University, Chabahar, Iran
| | - Massoud Kaykhaii
- Department of Process Engineering and Chemical Technology, Faculty of Chemistry, Gdansk University of Technology, G. Narutowicza St. 11/12, 80-233, Gdansk, Poland.
| | - Ahmad Jamali Keikha
- Department of Mechanical Engineering, Faculty of Marine Engineering, Chabahar Maritime University, Chabahar, Iran
| | - Ali Nasiriyan
- Mechanical Engineering Department, Faculty of Engineering, University of Sistan and Baluchestan, Zahedan, Iran
| |
Collapse
|
15
|
Carasek E, Morés L, Huelsmann RD. Disposable pipette extraction: A critical review of concepts, applications, and directions. Anal Chim Acta 2022; 1192:339383. [DOI: 10.1016/j.aca.2021.339383] [Citation(s) in RCA: 6] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/01/2021] [Revised: 12/15/2021] [Accepted: 12/16/2021] [Indexed: 01/14/2023]
|