1
|
Lee Y, Lee D, Lee H, Choe HS, Kim JH, Choi Y, Ahn J. Removal Efficiency of Bottom Ash and Sand Mixtures as Filter Layers for Fine Particulate Matter. MATERIALS (BASEL, SWITZERLAND) 2024; 17:2749. [PMID: 38894014 PMCID: PMC11173686 DOI: 10.3390/ma17112749] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 04/18/2024] [Revised: 05/23/2024] [Accepted: 05/28/2024] [Indexed: 06/21/2024]
Abstract
Permeable pavement is a technology that allows rainwater to infiltrate into the pavement. Permeable pavements not only help reduce surface runoff by allowing rainwater to infiltrate into the pavement, but also improve water quality with the filter layer that removes particulate matter pollutants. This study evaluated the particulate matter removal efficiency of bottom ash-sand mixtures as filter layers for removing fine (≤10 μm) or ultrafine (≤2.5 μm) particulate matter in the laboratory. Five filter media were tested: silica sand, bottom ash, and bottom ash-sand mixtures with 30:70, 50:50, and 70:30 ratios. The mixed filters exhibited more consistent and stable particulate matter removal efficiency over time than either the uniform sand or bottom ash filter. The 50:50 bottom ash-sand mixture demonstrated removal rates of 58.05% for 1.8 μm particles, 93.92% for 10 μm particles, and 92.45% for 60 μm particles. These findings highlight the potential of bottom ash-sand mixtures as effective filter media for removing PM10 road dust, although field validation with actual pavement systems is necessary.
Collapse
Affiliation(s)
- Yunje Lee
- Department of Civil and Environmental Engineering, Pusan National University, Busan 46241, Republic of Korea; (Y.L.); (H.-S.C.); (J.-H.K.)
| | - Donghyun Lee
- Global Business Energy Infra Team, HanmiGlobal Co., Ltd., Seoul 06164, Republic of Korea;
| | - Hongkyoung Lee
- Construction Division, NEODNC Co., Ltd., Busan 48106, Republic of Korea;
| | - Hyun-Seok Choe
- Department of Civil and Environmental Engineering, Pusan National University, Busan 46241, Republic of Korea; (Y.L.); (H.-S.C.); (J.-H.K.)
| | - Jae-Hyuk Kim
- Department of Civil and Environmental Engineering, Pusan National University, Busan 46241, Republic of Korea; (Y.L.); (H.-S.C.); (J.-H.K.)
| | - Yongjin Choi
- Maseeh Department of Civil Architectural and Environmental Engineering Austin, The University of Texas at Austin, Austin, TX 78712, USA
| | - Jaehun Ahn
- Department of Civil and Environmental Engineering, Pusan National University, Busan 46241, Republic of Korea; (Y.L.); (H.-S.C.); (J.-H.K.)
| |
Collapse
|
2
|
Raoelison OD, Das TK, Guyett K, Merrifield R, Visweswaran A, Indiresan S, Lin Yang K, Pierce G, Mohanty SK. Resilience of stormwater biofilters following the deposition of wildfire residues: Implication on downstream water quality management in wildfire-prone regions. JOURNAL OF HAZARDOUS MATERIALS 2024; 465:132989. [PMID: 38000283 DOI: 10.1016/j.jhazmat.2023.132989] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 09/20/2023] [Revised: 11/06/2023] [Accepted: 11/09/2023] [Indexed: 11/26/2023]
Abstract
Stormwater treatment systems such as biofilters could intercept and remove pollutants from contaminated runoff in wildfire-affected areas, ensuring the protection of water quality downstream. However, the deposition of wildfire residues such as ash and black carbon onto biofilters could potentially impair their stormwater treatment functions. Yet, whether and how wildfire residue deposition could affect biofilter functions is unknown. This study examines the impact of wildfire residue deposition on biofilter infiltration and pollutant removal capacities. Exposure to wildfire residues decreased the infiltration capacity based on the amount of wildfire deposited. Wildfire residues accumulated at the top layer of the biofilter, forming a cake layer, but scraping this layer restored the infiltration capacity. While the deposition of wildfire residues slightly changed the pore water geochemistry, it did not significantly alter the removal of metals and E. coli. Although wildfire residues leached some metals into pore water within the simulated root zone, the leached metals were effectively removed by the compost present in the filter media. Collectively, these results indicate that biofilters downstream of wildfire-prone areas could remain resilient or functional and protect downstream water quality if deposited ash is periodically scraped to restore any loss of infiltration capacity following wildfire residue deposition.
Collapse
Affiliation(s)
- Onja D Raoelison
- Civil and Environmental Engineering, The University of California Los Angeles, Los Angeles 90095, USA.
| | - Tonoy K Das
- Civil and Environmental Engineering, The University of California Los Angeles, Los Angeles 90095, USA
| | - Keegan Guyett
- Chemistry & Biochemistry, The University of California Los Angeles, Los Angeles 90095, USA
| | - Rachel Merrifield
- Civil and Environmental Engineering, The University of California Los Angeles, Los Angeles 90095, USA
| | - Ananya Visweswaran
- Civil and Environmental Engineering, The University of California Los Angeles, Los Angeles 90095, USA
| | - Shruti Indiresan
- Civil and Environmental Engineering, The University of California Los Angeles, Los Angeles 90095, USA
| | - Kevin Lin Yang
- Civil and Environmental Engineering, The University of California Los Angeles, Los Angeles 90095, USA
| | - Gregory Pierce
- Luskin Center for Innovation, Luskin School of Public Affairs, University of California, Los Angeles, CA 90095, USA
| | - Sanjay K Mohanty
- Civil and Environmental Engineering, The University of California Los Angeles, Los Angeles 90095, USA.
| |
Collapse
|
3
|
Yang J, Ren WX, Kang B, Tao Y. Experimental investigation on chemical clogging mechanism of loose porous media in recharge process of groundwater heat pump. ENVIRONMENTAL TECHNOLOGY 2023; 44:2357-2373. [PMID: 34962183 DOI: 10.1080/09593330.2021.2024275] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 09/22/2021] [Accepted: 12/23/2021] [Indexed: 06/08/2023]
Abstract
Groundwater heat pumps (GWHP) are an efficient utilisation of shallow geothermal energy technology and of great significance in terms of promoting energy conservation and reducing emissions. However, recharge clogging has been a key problem restricting the continuous operation of GWHP. In this study, a simulation test device for sand column was designed with the aim of addressing chemical clogging induced by heat pump reinjection in a porous saline aquifer in the Huaibei Plain, China. The trend in the variation of the permeability coefficient was studied based on the detection of the sand sample composition, recharge water quality, and sand layer temperature, and the cause of formation was analysed using the saturation index (SI) and ion ratio method. The results indicated that the permeability coefficient in the sand column decreased exponentially, with a maximum and minimum decrease of 8.14% and 71.65% of the original coefficient, respectively, found in sections P2-P3 and P8-P9. Therefore, the clogging effect of the aquifer at approximately 200-400 mm from the recharge well was significant. Water-rock interactions predominantly involved the dissolution of halite, albite, chlorite, anhydrite, and dolomite and the precipitation of calcite, as well as the exchange adsorption of Ca2+ and Mg2+ to Na+, which were the key sources of ions during the water chemical evolution process. Finally, quartz was formed by the weathering and dissolution of aluminosilicate minerals such as albite, and particle migration and precipitation during the hydrodynamic disturbance were the primary causes of the front-end blockage of the column.
Collapse
Affiliation(s)
- Jie Yang
- College of Civil Engineering, Hefei University of Technology, Hefei, People's Republic of China
- School of Architecture and Civil Engineering, West Anhui University, Lu'an, People's Republic of China
| | - Wei-Xin Ren
- College of Civil and Transportation Engineering, Shenzhen University, Shenzhen, People's Republic of China
| | - Bo Kang
- School of Resources and Environmental Engineering, Hefei University of Technology, Hefei, People's Republic of China
| | - Yuezan Tao
- College of Civil Engineering, Hefei University of Technology, Hefei, People's Republic of China
| |
Collapse
|
4
|
Marazuela MÁ, García-Gil A, Santamarta JC, Gasco-Cavero S, Cruz-Pérez N, Hofmann T. Stormwater management in urban areas using dry gallery infiltration systems. THE SCIENCE OF THE TOTAL ENVIRONMENT 2022; 823:153705. [PMID: 35134423 DOI: 10.1016/j.scitotenv.2022.153705] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 12/20/2021] [Revised: 02/02/2022] [Accepted: 02/02/2022] [Indexed: 06/14/2023]
Abstract
The increase in the frequency of extreme precipitation events due to climate change, together with the continuous development of cities and surface sealing that hinder water infiltration into the subsoil, is accelerating the search for new facilities to manage stormwater. The Canary Islands (Spain) are taking advantage of the knowledge acquired in the construction of water mines to exploit a novel stormwater management facility, which we have defined as a dry gallery. Dry galleries are constituted by a vertical well connected to a horizontal gallery dug into highly permeable volcanic layers of the vadose zone, from where infiltration takes place. However, the lack of scientific knowledge about these facilities prevents them from being properly dimensioned and managed. In this work, we simulate for the first time the infiltration process and the wetting front propagation from dry galleries based on a 3D unsaturated flow model and provide some recommendations for the installation and sizing of these facilities. The fastest advance of the wetting front takes place during the earliest times of infiltration (<2 h), with plausible propagation velocities and infiltration rates higher than 1000 m∙d-1 and 2 m3∙s-1. As time progresses, the propagation velocity and infiltration rate decrease as a consequence of the hydraulic gradient attenuation between the gallery and the aquifer. Therefore, stormwater infiltration is a highly transient process in which a sizing underestimation of 100% may be committed if unsaturated conditions or geological configuration are neglected.
Collapse
Affiliation(s)
- Miguel Ángel Marazuela
- Centre for Microbiology and Environmental Systems Science, Department of Environmental Geosciences, University of Vienna, Althanstrasse 14 UZAII, 1090 Vienna, Austria.
| | | | - Juan C Santamarta
- Agriculture, Nautical, Civil and Maritime Engineering Department. University of La Laguna (ULL), Ctra. Geneto, 2, La Laguna, 38200 Tenerife, Canary Islands, Spain
| | | | - Noelia Cruz-Pérez
- Agriculture, Nautical, Civil and Maritime Engineering Department. University of La Laguna (ULL), Ctra. Geneto, 2, La Laguna, 38200 Tenerife, Canary Islands, Spain
| | - Thilo Hofmann
- Centre for Microbiology and Environmental Systems Science, Department of Environmental Geosciences, University of Vienna, Althanstrasse 14 UZAII, 1090 Vienna, Austria
| |
Collapse
|
5
|
Design of Constructed Wetland Treatment Measures for Highway Runoff in a Water Source Protection Area. SUSTAINABILITY 2022. [DOI: 10.3390/su14105951] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 02/05/2023]
Abstract
Road runoff contains high levels of pollutants, such as heavy metals and hydrocarbons. If they are directly discharged into sensitive water bodies, they will cause irreversible pollution and damage to the water environment. Furthermore, the leakage of hazardous chemicals into sensitive waters will lead to serious consequences, so determining how to deal with road surface runoff has become an urgent problem. This research adopts a scheme for collecting and processing road runoff in a water source protection area using artificial wetlands. After optimizing and improving the general vertical flow of the wetland structure, a composite wetland structure and a relatively novel tandem wetland structure are proposed. An indoor model is established for experiments on various main wetland structure schemes. The results show that the two newly proposed wetland structures improve the possibility of water level control in general vertical flow structures. At the same time, the movement distance of the water flow in the wetland structure is changed to improve the treatment effect of runoff. The removal effect of composite and tandem wetland structures for heavy metals, petroleum substances, and COD (chemical oxygen demand) is significantly better than that of general vertical flow structures. Among them, the composite structure is better than the tandem structure at removing heavy metals, petroleum substances, and COD. However, due to the water discharge method of the structures, the latter has a better effect than the former in the treatment of suspended substances.
Collapse
|
6
|
Stricker M, Littfinski T, Heinz E, Pecher KH, Lübken M, Grüning H, Wichern M. Design-oriented evaluation of the hydrodynamics in a full-scale combined filter-lamella separator for urban stormwater treatment. WATER SCIENCE AND TECHNOLOGY : A JOURNAL OF THE INTERNATIONAL ASSOCIATION ON WATER POLLUTION RESEARCH 2022; 85:2854-2868. [PMID: 35638792 DOI: 10.2166/wst.2022.135] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/15/2023]
Abstract
The development of compact treatment devices with high removal efficiencies and low space requirements is a key objective of urban stormwater treatment. Thus, many devices utilize a combination of sedimentation and upward flow filtration in a single system. This study, for the first time, evaluates the flow field inside a combined filter-lamella separator via computational fluid dynamics. Herein, three objectives are investigated: (i) the flow field for different structural configurations, (ii) the distribution of particulate matter along the filter bed and (iii) the dynamic clogging in discrete filter zones, which is addressed by a clogging model derived from literature data. The results indicate that a direct combination of a filtration stage with a lamella separator promotes a uniform flow distribution. The distribution of particulate matter along the filter bed varies with configuration and particle size. Clogging, induced by particles in the spectrum <63 μm, creates gradients of hydraulic conductivity along the filter bed. After treating about half of Germany's annual runoff-efficient precipitation at a rainfall intensity of 5 L/(s·ha), the filtration rates increase in the front of the filter bed by +10%. Thus, long-term operating behavior is sensitive to efficient filter utilization in compact treatment devices.
Collapse
Affiliation(s)
- Max Stricker
- Department of Civil and Environmental Engineering, Institute of Urban Water Management and Environmental Engineering, Ruhr-Universität Bochum, Universitätsstraße 150, Bochum 44801, Germany E-mail:
| | - Tobias Littfinski
- Department of Civil and Environmental Engineering, Institute of Urban Water Management and Environmental Engineering, Ruhr-Universität Bochum, Universitätsstraße 150, Bochum 44801, Germany E-mail:
| | - Eva Heinz
- Department of Civil and Environmental Engineering, Institute of Urban Water Management and Environmental Engineering, Ruhr-Universität Bochum, Universitätsstraße 150, Bochum 44801, Germany E-mail:
| | | | - Manfred Lübken
- Department of Civil and Environmental Engineering, Institute of Urban Water Management and Environmental Engineering, Ruhr-Universität Bochum, Universitätsstraße 150, Bochum 44801, Germany E-mail:
| | - Helmut Grüning
- Faculty of Energy, Building Services, Environmental Engineering, University of Applied Sciences Münster, Stegerwaldstraße 39, Steinfurt 48565, Germany
| | - Marc Wichern
- Department of Civil and Environmental Engineering, Institute of Urban Water Management and Environmental Engineering, Ruhr-Universität Bochum, Universitätsstraße 150, Bochum 44801, Germany E-mail:
| |
Collapse
|
7
|
Hermawan AA, Teh KL, Talei A, Chua LHC. Accumulation of heavy metals in stormwater biofiltration systems augmented with zeolite and fly ash. JOURNAL OF ENVIRONMENTAL MANAGEMENT 2021; 297:113298. [PMID: 34280854 DOI: 10.1016/j.jenvman.2021.113298] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 04/12/2021] [Revised: 06/19/2021] [Accepted: 07/13/2021] [Indexed: 06/13/2023]
Abstract
The discharge of high levels of heavy metals into the environment is of concern due to its toxicity to aquatic life and potential human health impacts. Biofiltration systems have been used in urban environments to address nutrient contamination, but there is also evidence that such systems can be effective in reducing heavy metals concentration in stormwater. However, the accumulation pattern of heavy metals and lifespan of such systems, which are important in engineering design, have not been thoroughly explored. This study investigated the accumulation patterns of lead (Pb), copper (Cu), zinc (Zn), manganese (Mn), and iron (Fe), which are common in urban runoff, in non-vegetated filtration columns using three different types of filter media, namely sand (S), and mixtures of sand with fly ash (sand-fly ash mix, SF), and with zeolite (sand-zeolite mix, SZ). The columns were assessed in terms of infiltration rate, the mass of heavy metals accumulation at different depths, and formation of crust layer (schmutzdecke) at the surface. The results show that most of the heavy metals accumulated at the top 5-10 cm of the filter media. However, Zn was found adsorbed to a depth of 15 cm in S and SZ columns, while Mn and Fe were present in column S throughout the entire 30 cm depth of the filter media. The presence especially of Zn, Mn, and Fe in the deeper portions of the filter media before the top 5 cm layer reached its maximum adsorption capacity, hints that transport to the deeper layers is not necessarily dependent on saturation of the upper layers for these heavy metals. SF accumulated heavy metals most at the top 5 cm of the filter media layer, and retained twice the mass of heavy metals in the crust layer, compared to S and SZ columns. SF also yielded the lowest value of infiltration rate of 31 mm/h. Considering both metals accumulation and clogging potential of the filter media, the periodic maintenance of these systems is suggested to be approximately between 1.5 and 3 years.
Collapse
Affiliation(s)
- Andreas Aditya Hermawan
- Discipline of Civil Engineering, School of Engineering, Monash University Malaysia, Jalan Lagoon Selatan, Bandar Sunway, Selangor, 47500, Malaysia
| | - Kok Leong Teh
- Discipline of Civil Engineering, School of Engineering, Monash University Malaysia, Jalan Lagoon Selatan, Bandar Sunway, Selangor, 47500, Malaysia
| | - Amin Talei
- Discipline of Civil Engineering, School of Engineering, Monash University Malaysia, Jalan Lagoon Selatan, Bandar Sunway, Selangor, 47500, Malaysia.
| | - Lloyd H C Chua
- School of Engineering, Deakin University, 75 Pigdons Road, Waurn Ponds, VIC, 3220, Australia
| |
Collapse
|
8
|
Modeling of the Suspended Solid Removal of a Granular Media Layer in an Upflow Stormwater Runoff Filtration System. APPLIED SCIENCES-BASEL 2021. [DOI: 10.3390/app11136202] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/17/2022]
Abstract
Upflow granular media filtration devices are widely used for stormwater runoff treatment. However, the system performance is not well characterized due to the irregular removal of suspended solid (SS) in the pretreatment (sedimentation) chamber and, hence, its irregular input to the media layer. In this regard, the performance of the granular media layer of an upflow filtration system is investigated herein by the use of various models. Due to the significant variation in the SS concentration of the influent and effluent to and from the media layer, the deep bed filtration model, the k-C* model, and the porous media capture model provide limited descriptions of the system performance. By contrast, the performance is well described using the kinetic model, the modified k-C* model using a specific deposit, and the modified porous media capture model using a specific deposit. The parameters of the latter models are shown to be in good correlation with the filtration velocity, SS removal, and specific deposit. The results suggest that modeling using a specific SS deposit can provide an accurate description of the granular media layer performance under a highly variable influent SS concentration.
Collapse
|
9
|
Pilot and Field Studies of Modular Bioretention Tree System with Talipariti tiliaceum and Engineered Soil Filter Media in the Tropics. WATER 2021. [DOI: 10.3390/w13131817] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/16/2022]
Abstract
Stormwater runoff management is challenging in a highly urbanised tropical environment due to the unique space constraints and tropical climate conditions. A modular bioretention tree (MBT) with a small footprint and a reduced on-site installation time was explored for application in a tropical environment. Tree species used in the pilot studies were Talipariti tiliaceum (TT1) and Sterculia macrophylla (TT2). Both of the MBTs could effectively remove total suspended solids (TSS), total phosphorus (TP), zinc, copper, cadmium, and lead with removal efficiencies of greater than 90%. Total nitrogen (TN) removal was noted to be significantly higher in the wet period compared to the dry period (p < 0.05). Variation in TN removal between TT1 and TT2 were attributed to the nitrogen uptake and the root formation of the trees species. A field study MBT using Talipariti tiliaceum had a very clean effluent quality, with average TSS, TP, and TN effluent EMC of 4.8 mg/L, 0.04 mg/L, and 0.27 mg/L, respectively. Key environmental factors were also investigated to study their impact on the performance of BMT. It was found that the initial pollutant concentration, the dissolved fraction of influent pollutants, and soil moisture affect the performance of the MBT. Based on the results from this study, the MBT demonstrates good capability in the improvement of stormwater runoff quality.
Collapse
|
10
|
Hwang Y, Seo Y, Kim H, Roh K, Kim D. Evaluation of solids removal and optimisation of backwashing for an upflow stormwater filtration system utilising novel floating fibrous media. ENVIRONMENTAL TECHNOLOGY 2021; 42:2132-2144. [PMID: 31725366 DOI: 10.1080/09593330.2019.1694080] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 03/15/2019] [Accepted: 11/10/2019] [Indexed: 06/10/2023]
Abstract
Although filtration devices are already widely used for stormwater runoff treatment, there are much to be improved to ensure the required performance. Additionally, the performance of a device should be verified before on-site installation. In this context, an upflow filtration system using novel high porosity floating fibrous media formed into spherical shape was proposed and evaluated for solid capture and backwashing. At filtration velocities of 20-40 m/h, the maximum head loss was about 2 cm even under a solid load of 30 kg/m2, and suspended solid (SS) removal efficiency was >96% throughout 300 min. A considerable amount of SS was removed in the pretreatment chamber, so the load on the media was reduced. Several models were tried to describe the solid capture in the media. The coefficients of solid attachment/detachment showed good correlations with filtration velocity. Other parameters indicated a variation of solid capture and permeability, which is unique to the media in this study. The backwashing with air and water for 1-2 min each showed good head loss recovery under the SS load up to 550-600 kg/m2, and the SS discharge was more efficient when the stagnant water was drained before water backwashing. The results in this study suggest the high potential of the combination of fibrous media and upflow filtration system for the efficient control of the nonpoint source pollutants in stormwater runoff.
Collapse
Affiliation(s)
- Yuhoon Hwang
- Department of Environmental Engineering, Seoul National University of Science and Technology, Seoul, Republic of Korea
| | - Younggyo Seo
- Department of Environmental Engineering, Seoul National University of Science and Technology, Seoul, Republic of Korea
| | - Hyowon Kim
- Department of Environmental Engineering, Seoul National University of Science and Technology, Seoul, Republic of Korea
| | | | - Dogun Kim
- Department of Civil Engineering, Kyung Hee University, Yongin-si, Republic of Korea
| |
Collapse
|
11
|
Abstract
Urbanization has replaced natural permeable surfaces with roofs, roads, and other sealed surfaces, which convert rainfall into runoff that finally is carried away by the local sewage system. High intensity rainfall can cause flooding when the city sewer system fails to carry the amounts of runoff offsite. Although projects, such as low-impact development and water-sensitive urban design, have been proposed to retain, detain, infiltrate, harvest, evaporate, transpire, or re-use rainwater on-site, urban flooding is still a serious, unresolved problem. This review sequentially discusses runoff reduction facilities installed above the ground, at the ground surface, and underground. Mainstream techniques include green roofs, non-vegetated roofs, permeable pavements, water-retaining pavements, infiltration trenches, trees, rainwater harvest, rain garden, vegetated filter strip, swale, and soakaways. While these techniques function differently, they share a common characteristic; that is, they can effectively reduce runoff for small rainfalls but lead to overflow in the case of heavy rainfalls. In addition, most of these techniques require sizable land areas for construction. The end of this review highlights the necessity of developing novel, discharge-controllable facilities that can attenuate the peak flow of urban runoff by extending the duration of the runoff discharge.
Collapse
|
12
|
Hong J, Ko D, Hwang Y. Disulfide polymer grafted polypropylene/polyethylene filter media for selective cadmium removal. JOURNAL OF HAZARDOUS MATERIALS 2020; 399:123060. [PMID: 32937714 DOI: 10.1016/j.jhazmat.2020.123060] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 02/25/2020] [Revised: 05/20/2020] [Accepted: 05/25/2020] [Indexed: 06/11/2023]
Abstract
Heavy metal pollution caused by stormwater runoff has triggered a demand for effective heavy metal sorbents. Effective heavy metal removal using conventional stormwater runoff treatment processes that employ filtration mechanisms as primary removal mechanisms is difficult. Therefore, we attempt to improve cadmium removal performance by attaching disulfide polymer (DiS-COP) containing soft bases, thiols, onto the surface of polypropylene/polyethylene (PP/PE) fiber media, which is widely used for stormwater runoff treatment. Material characterization demonstrated that DiS-COP was successfully grafted and grown on the surface of PP/PE (Dis-PP/PE). The batch and continuous flow adsorption capacities of Dis-PP/PE were 81.1 mg/g and 2.33 mg/g, respectively, which is 40 times higher than those of pristine PP/PE. Applicability of DiS-PP/PE at pH 6-8 was demonstrated, and effects of calcium and humic acid on cadmium adsorption were investigated. Calcium marginally affected cadmium adsorption, which can be explained using the Hard and soft (Lewis) acids and bases theory (HSAB), but cadmium removal efficiency decreased owing to humic acid (HA)-Cd complex formation and agglomeration in the presence of organic material. In a breakthrough test, the adsorption column exhibited complete cadmium uptake over 24 h until it reached the breakthrough point. Therefore, heavy metal adsorption performance of PP/PE was successfully enhanced by grafting DiS-COP on its surface.
Collapse
Affiliation(s)
- Jeongmin Hong
- Department of Environmental Engineering, Seoul National University of Science and Technology, Seoul 01811, Republic of Korea
| | - Dongah Ko
- Innovation Centre Denmark, Seoul 04637, Republic of Korea
| | - Yuhoon Hwang
- Department of Environmental Engineering, Seoul National University of Science and Technology, Seoul 01811, Republic of Korea.
| |
Collapse
|
13
|
Le H, Valenca R, Ravi S, Stenstrom MK, Mohanty SK. Size-dependent biochar breaking under compaction: Implications on clogging and pathogen removal in biofilters. ENVIRONMENTAL POLLUTION (BARKING, ESSEX : 1987) 2020; 266:115195. [PMID: 32683234 DOI: 10.1016/j.envpol.2020.115195] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 05/23/2020] [Revised: 07/02/2020] [Accepted: 07/05/2020] [Indexed: 06/11/2023]
Abstract
Breaking of biochar during compaction of amended soil in roadside biofilters or landfill cover can affect infiltration and pollutant removal capacity. It is unknown how the initial biochar size affects the biochar breaking, clogging potential, and contaminant removal capacity of the biochar-amended soil. We compacted a mixture of coarse sand and biochar with sizes smaller than, similar to, or larger than the sand in columns and applied stormwater contaminated with E. coli. Packing columns with biochar pre-coated with a dye and analyzing the dye concentration in the broken biochar particles eluted from the columns, we proved that biochar predominantly breaks under compaction by disintegration or splitting, not by abrasion. Increases in biochar size decrease the likelihood of biochar breaking. We attribute this result to the effective dissipation of compaction energy through a greater number of contact points between a large biochar particle and the adjacent particles. Most of the broken biochar particles are deposited in the pore spaces of the background geomedia, resulting in an exponential decrease in hydraulic conductivity of amended sand with an increase in suspended sediment loading. The clogging rate was higher in the columns with small biochar. The columns with small biochar also exhibited high E. coli removal capacity, partly because of an increase in bacterial straining at reduced pore size after compaction. These results are useful in selecting appropriate biochar size for its application in soils and roadside biofilters for stormwater treatment.
Collapse
Affiliation(s)
- Huong Le
- Department of Civil and Environmental Engineering, University of California, Los Angeles, USA
| | - Renan Valenca
- Department of Civil and Environmental Engineering, University of California, Los Angeles, USA
| | - Sujith Ravi
- Department of Earth and Environmental Science, Temple University, Philadelphia, USA
| | - Michael K Stenstrom
- Department of Civil and Environmental Engineering, University of California, Los Angeles, USA
| | - Sanjay K Mohanty
- Department of Civil and Environmental Engineering, University of California, Los Angeles, USA.
| |
Collapse
|
14
|
Zaidi M, Ahfir ND, Alem A, El Mansouri B, Wang H, Taibi S, Duchemin B, Merzouk A. Assessment of clogging of managed aquifer recharge in a semi-arid region. THE SCIENCE OF THE TOTAL ENVIRONMENT 2020; 730:139107. [PMID: 32402970 DOI: 10.1016/j.scitotenv.2020.139107] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 03/05/2020] [Revised: 04/06/2020] [Accepted: 04/27/2020] [Indexed: 06/11/2023]
Abstract
To overcome water scarcity issues in arid and semi-arid regions, Managed Aquifer Recharge (MAR) remains a viable and suitable solution to manage and restore aquifers. However, clogging represents a major issue that can affect the durability and efficiency of MAR structures. The aim of this study was to evaluate the extent of clogging in MAR sites (Berrechid, Morocco). To achieve this objective, two field-based studies were undertaken: the first one consists of implantation of sand-filled columns in the recharge sites to evaluate the surface and subsurface clogging. The second one consists of the implantation of pickets over a 750 m2 area in each recharge site to measure the extent of deposit thickness on the surface of the wadi bed. Results show that, despite the low rainfall (<1.4 mm/day) and the short period (91 days) of the study, the deposits thickness exceeds 3 cm in a large part of the MAR. The suspended solids concentrations measured in recharge sites ranged from 1.1 to 1.4 g/L. Due to the particles retention, the estimation of the saturated hydraulic conductivity (k) of the sand declines over 90% in the immediate entrance of the columns. The k values measured in situ during the drying period ranged from 10-5 to 10-6 m/s. The k values of the cake formed, without cracks, was about 10-8 m/s. The presence of cracks drives the entire infiltration. However, due to the high plasticity index of the MAR soil, a slight reduction of cracks opening during wetting cycles is observed. In addition, particles deposited in these cracks, would contribute actively to the reduction of infiltration. The results of this study clearly showed the MAR sites vulnerability in semi-arid regions due to physical clogging.
Collapse
Affiliation(s)
- Mohammed Zaidi
- Normandie Univ., UNIHAVRE, UMR 6294 CNRS, LOMC, 76600 Le Havre, France; Laboratory of Geosciences of Natural Resources, Hydroinformatic section, Faculty of Sciences, Ibn Tofail University, Maamora Campus, BP.133, 14000 Kénitra, Morocco
| | - Nasre-Dine Ahfir
- Normandie Univ., UNIHAVRE, UMR 6294 CNRS, LOMC, 76600 Le Havre, France.
| | - Abdellah Alem
- Normandie Univ., UNIHAVRE, UMR 6294 CNRS, LOMC, 76600 Le Havre, France
| | - Bouabid El Mansouri
- Laboratory of Geosciences of Natural Resources, Hydroinformatic section, Faculty of Sciences, Ibn Tofail University, Maamora Campus, BP.133, 14000 Kénitra, Morocco
| | - Huaqing Wang
- Normandie Univ., UNIHAVRE, UMR 6294 CNRS, LOMC, 76600 Le Havre, France
| | - Said Taibi
- Normandie Univ., UNIHAVRE, UMR 6294 CNRS, LOMC, 76600 Le Havre, France
| | - Benoît Duchemin
- Normandie Univ., UNIHAVRE, UMR 6294 CNRS, LOMC, 76600 Le Havre, France
| | - Abdesselam Merzouk
- Laboratory of Geosciences of Natural Resources, Hydroinformatic section, Faculty of Sciences, Ibn Tofail University, Maamora Campus, BP.133, 14000 Kénitra, Morocco
| |
Collapse
|
15
|
Preparation and Component Optimization of Resin-Based Permeable Brick. MATERIALS 2020; 13:ma13122701. [PMID: 32545752 PMCID: PMC7345620 DOI: 10.3390/ma13122701] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 05/22/2020] [Revised: 06/07/2020] [Accepted: 06/10/2020] [Indexed: 11/29/2022]
Abstract
The present study aims to prepare resin-based permeable bricks with micron-sized pores using fine aggregate with a particle diameter of 0.08–0.6 mm and bisphenol-A epoxy resin, a polymer binder. The properties of the binder, the characteristic parameters of the aggregate, and the micro pore structure of the brick were studied in order to break through the limitations of traditional porous permeable materials. The dynamic mechanical properties of resin were analyzed by dynamic mechanical analysis (DMA). The frequency parameter of particle size of 10 kinds of aggregate from different regions were obtained by digital image processing, and the characteristic parameter (aggregate distribution coefficient α) was obtained by modified Gaussian distribution. The microstructure of porous brick was analyzed by scanning electron microscopy-energy-dispersive X-ray spectroscopy (SEM-EDS). The test results show: (1) the glass transition temperature (Tg) of the resin is 61 °C; (2) the parameters of aggregate particle group will affect the performance of porous permeable materials; (3) the minimum effective pore diameter of the permeable brick is 30 μm, the maximum permeable rate is 6.22×10−2 cm/s and the compressive strength is 41.08 MPa. The conclusions of this study will provide an important reference for permeable materials in the micron-scale pore range and the selection of binder and aggregate materials.
Collapse
|
16
|
Conley G, Beck N, Riihimaki CA, Tanner M. Quantifying clogging patterns of infiltration systems to improve urban stormwater pollution reduction estimates. WATER RESEARCH X 2020; 7:100049. [PMID: 32211601 PMCID: PMC7082631 DOI: 10.1016/j.wroa.2020.100049] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 12/23/2019] [Revised: 03/07/2020] [Accepted: 03/07/2020] [Indexed: 06/04/2023]
Abstract
Infiltration systems are among the most commonly implemented practices to control urban stormwater and to attenuate pollutant delivery to receiving waters, because they are relatively cheap to build and amenable to space constraints in urbanized areas. However, infiltration systems tend to clog with sediments, which can rapidly reduce their performance. While clogging has been consistently identified as a significant determinant on infiltration BMP (best management practice) performance and lifespan, there have been few methods reported to predict rates of clogging or incorporate insights to urban catchment water quality modeling. We ran a series of laboratory and field experiments to identify clogging mechanisms and quantify infiltration performance declines as a function of sediment loading. The results show rapid initial declines of infiltration rate, primarily due to accumulation of material at the bottom of the infiltration BMP. The performance decline trajectories were sensitive to BMP geometry, with BMPs that had greater lateral infiltration surface area declining less quickly. We integrated these experimental results to a spatially distributed stormwater model to illustrate how they can be used to predict BMP performance declines over time and assess cost trade-offs. Results will be used to adapt algorithms in a cloud-based stormwater management platform to better inform maintenance needs for cities and improve the accuracy of urban stormwater pollutant load reduction estimates that support regulatory compliance tracking.
Collapse
Affiliation(s)
- Gary Conley
- 2NDNATURE, 500 Seabright Avenue, Santa Cruz, CA, 95062, USA
| | - Nicole Beck
- 2NDNATURE, 500 Seabright Avenue, Santa Cruz, CA, 95062, USA
| | - Catherine A. Riihimaki
- Princeton University, Council on Science and Technology, 234 Lewis Library, Princeton, NJ, 08544, USA
| | | |
Collapse
|
17
|
Application of Bottom Ash as Filter Media for Construction Site Runoff Control. WATER 2020. [DOI: 10.3390/w12040990] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/16/2022]
Abstract
The potential application of bottom ash (BA) for construction site runoff control as an alternative filter media with high removal efficiency of total suspended solids (TSS) and longer operation period were evaluated. Both lab-scale single-layer and pilot-scale multi-layer filtration experiments were performed using BA filter media with different particle sizes and various volumetric flow rates. Due to the mesoporous, irregular, and spherical shape of gravel-size BA filter media used in this study, relatively low surface area, negligible pore volume, and greater pore size were observed. Both TSS removal efficiencies and clogging of BA filter media were a complex function of particle size of BA filter media and loading rate of TSS. Incoming TSS particles did not significantly penetrate beyond 46-cm BA filter media depth, accumulating on the upper layers and gradually forming a clogging layer to critical thickness, and finally the clogging filtration mechanism dominated the overall removal efficiency of TSS. Accumulation of TSS on BA filter media can be explained by the lumped sigmoidal empirical model, and an exponential decline in accumulation of TSS with depth results in minimal accumulation beneath the clogging layer. As practical implications, BA filter media depth of less than 46 cm is recommended with dual- or multi-media filters using mixtures of gravel-size BA and silt-size fine media, and a combination of detention basins can reduce frequent periodic de-clogging operation and management.
Collapse
|
18
|
Jiang C, Li J, Li H, Li Y. Remediation and accumulation characteristics of dissolved pollutants for stormwater in improved bioretention basins. THE SCIENCE OF THE TOTAL ENVIRONMENT 2019; 685:763-771. [PMID: 31234138 DOI: 10.1016/j.scitotenv.2019.06.246] [Citation(s) in RCA: 14] [Impact Index Per Article: 2.8] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 02/28/2019] [Revised: 05/27/2019] [Accepted: 06/16/2019] [Indexed: 06/09/2023]
Abstract
Dissolved pollutants in stormwater are more mobile/bioavailable, and are captured via different mechanisms than particles. Column-scale bioretention basins are constructed by filling different media, which is used to study the remediation and accumulation characteristics of dissolved pollutants by improved bioretention basins (increased infiltration and adsorption capacity of the media). The media factor (ratio of specific surface area to cubic of porosity) is used to characterize the basic properties of different media, while considering the key factors: infiltration capacity, inflow concentration, recurrence interval, discharge ratio, antecedent dry period, and rainfall duration. The results showed that stormwater pollutants load reduction rate decreased with the increase of recurrence interval and discharge ratio, and increased with the increase of inflow concentration. Based on response surface methodology (RSM), a quantitative relationship model between major pollutants and influencing factors were established (R2 > 0.715), which can be used to estimate the design and operation of the media. By detecting changes in media carbon, nitrogen and phosphorus contents, the results showed that partial pollutants leaching were greater than their accumulation in the initial stage of system operation, and their contents in the media reduced during simulated rainfall. After the pollution contents tend to stabilize, the accumulated pollutants were greater than the leaching, and media pollution contents showed the trend of upper > middle > lower (corresponding to the 10, 35, and 60 cm sections of the media from top to bottom). Six enzymes closely related to the accumulation and migration of nitrogen, phosphorus and organic matter in the media were selected. Pearson correlation analysis found that: the significant correlations between the selected enzyme activity and pollutants were not consistent in bioretention system. For example, catalase was significantly correlated with all the pollutants (P < 0.01), whereas acid phosphatase was not significantly correlated with all the pollutants.
Collapse
Affiliation(s)
- Chunbo Jiang
- State Key Laboratory of Eco-hydraulics in Northwest Arid Region of China, Xi'an University of Technology, Xi'an 710048, China
| | - Jiake Li
- State Key Laboratory of Eco-hydraulics in Northwest Arid Region of China, Xi'an University of Technology, Xi'an 710048, China.
| | - Huaien Li
- State Key Laboratory of Eco-hydraulics in Northwest Arid Region of China, Xi'an University of Technology, Xi'an 710048, China
| | - Yajiao Li
- School of Architecture and Civil Engineering, Xi'an University of Science and Technology, Xi'an 710054, China
| |
Collapse
|
19
|
Yang Q, Beecham S, Liu J, Pezzaniti D. The influence of rainfall intensity and duration on sediment pathways and subsequent clogging in permeable pavements. JOURNAL OF ENVIRONMENTAL MANAGEMENT 2019; 246:730-736. [PMID: 31220733 DOI: 10.1016/j.jenvman.2019.05.151] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 03/12/2019] [Revised: 05/30/2019] [Accepted: 05/30/2019] [Indexed: 06/09/2023]
Abstract
The trapping of sediments within permeable pavements during infiltration is an important process that contributes to their water quality treatment performance. However, this process also leads to clogging, which decreases the infiltration capacity of the pavement. With different rainfall intensities and durations, this study investigates the amount and size of sediment passing through a porous paver, as well as through the gravel-filled gaps that separate adjacent pavers. One of the major challenges in this study was to design an experiment where the characteristics of the sediment particles that are trapped while passing through these two different infiltration pathways are assessed. This was overcome by developing a new type of rainfall application device in combination with a two-tiered sediment capturing system. A better understanding of the infiltration pathways of sediment and the associated clogging processes should help designers improve the effective life of permeable pavements. Overall, it was found that while the porosity of porous pavers serves a useful function in terms of removing excess surface water during and after a rainfall event, it serves little purpose in removing sediment from stormwater.
Collapse
Affiliation(s)
- Qiuxia Yang
- (a)Xi'an University of Architecture and Technology, Australia.
| | | | - Jixue Liu
- University of South Australia, Australia.
| | | |
Collapse
|
20
|
Physical Experiment and Modeling of the Transport and Deposition of Polydisperse Particles in Stormwater: Effects of a Depth-Dependent Initial Filter Coefficient. WATER 2019. [DOI: 10.3390/w11091885] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/17/2022]
Abstract
The artificial recharge of stormwater is an effective approach for replenishing aquifer and reduce urban waterlogging, but prone to clogging by suspended particles (SP) that are highly heterogeneously sized. In this paper, the transport and deposition of SP in a sand column were investigated under a constant flow condition, for five stormwater concentrations. A depth-dependent initial filter coefficient is incorporated into the conventional filtration model. This modified model considers the heterogeneity of the particle population by lumping the capture of heterogeneous SP into a capture probability. The good agreement between the results of the modified model and the experimental results of measured outlet concentration and average specific deposit validated the modified model. The experiment data and the simulation results both indicate that the highly hyper-exponential retention profiles are caused by non-uniform deposition of heterogeneous SP; and, the conventional model was found to homogenize the spatial distribution of SP retention and overestimate retention of the porous medium. Local and overall permeability reductions were assessed by an empirical relationship and the Kozeny-Carman model, respectively. It is shown that consideration of polydisperse suspended particles is of primary importance. This study highlights the effects of polydisperse particles on SP deposition in a saturated porous medium.
Collapse
|
21
|
Ye X, Cui R, Du X, Ma S, Zhao J, Lu Y, Wan Y. Mechanism of Suspended Kaolinite Particle Clogging in Porous Media During Managed Aquifer Recharge. GROUND WATER 2019; 57:764-771. [PMID: 30802943 DOI: 10.1111/gwat.12872] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 10/09/2018] [Revised: 02/14/2019] [Accepted: 02/22/2019] [Indexed: 06/09/2023]
Abstract
Managed aquifer recharge is an effective strategy for urban stormwater management. Chemical ions are normally retained in stormwater and groundwater and may accelerate clogging during the recharge process. However, the effect of water chemistry on physical clogging has not previously been investigated. In this study, we investigated the hydrogeochemical mechanism of saturated porous media clogging in a series of column experiments. The column was packed with river sand and added suspensions of kaolinite particles. Calcium chloride and sodium chloride are used as representative ions to study chemical effects. We found that an increase in ionic strength resulted in retention of kaolinite solids in the column, with a breakthrough peak of C/C0 value of 1 to 0.2. The corresponding hydraulic conductivity decreased with increased solids clogging. Divalent cations were also found to have a greater influence on kaolinite particle clogging than monovalent cations. The enhanced hydrochemical-related clogging was caused by kaolinite solids flocculating and increasing the deposition rate coefficient by 1 to 2 times in high ionic strength conditions. Three clogging mechanisms of kaolinite solids are proposed: surface filtration, inner blocking, and attachment. This study further deepens the understanding of the mechanisms of solids clogging during aquifer recharge and demonstrates the significance of ionic strength on recharge clogging risk assessments.
Collapse
Affiliation(s)
- Xueyan Ye
- Key Laboratory of Groundwater Resources and Environment, Ministry of Education, Jilin University, Changchun 130021, China
- Jilin Provincial Key Laboratory of Water Resources and Environment, Jilin University, Changchun 130021, China
- College of New Energy and Environment, Jilin University, Changchun 130021, China
| | - Ruijuan Cui
- Key Laboratory of Groundwater Resources and Environment, Ministry of Education, Jilin University, Changchun 130021, China
- Jilin Provincial Key Laboratory of Water Resources and Environment, Jilin University, Changchun 130021, China
- College of New Energy and Environment, Jilin University, Changchun 130021, China
| | - Xinqiang Du
- Jilin Provincial Key Laboratory of Water Resources and Environment, Jilin University, Changchun 130021, China
- College of New Energy and Environment, Jilin University, Changchun 130021, China
| | - Sijia Ma
- College of New Energy and Environment, Jilin University, Changchun 130021, China
| | - Jingtong Zhao
- College of New Energy and Environment, Jilin University, Changchun 130021, China
| | - Ying Lu
- Key Laboratory of Groundwater Resources and Environment, Ministry of Education, Jilin University, Changchun 130021, China
- Jilin Provincial Key Laboratory of Water Resources and Environment, Jilin University, Changchun 130021, China
- College of New Energy and Environment, Jilin University, Changchun 130021, China
| | - Yuyu Wan
- Key Laboratory of Groundwater Resources and Environment, Ministry of Education, Jilin University, Changchun 130021, China
- Jilin Provincial Key Laboratory of Water Resources and Environment, Jilin University, Changchun 130021, China
- College of New Energy and Environment, Jilin University, Changchun 130021, China
| |
Collapse
|
22
|
Clogging of Infiltration Basin and Its Impact on Suspended Particles Transport in Unconfined Sand Aquifer: Insights from a Laboratory Study. WATER 2019. [DOI: 10.3390/w11051083] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/16/2022]
Abstract
A laboratory study was undertaken to investigate the physical clogging of a sand medium by injecting suspended particles (SP), with diameters ranging from 0.03 to 63.41 μm, into an infiltration basin, which was installed in a sand tank under the condition of constant head. The hydraulic conductivity (K) of the saturated porous medium was found to have decreased by 27% because of re-arrangement over the seven days of self-filtration. A clogging layer was observed on the infiltration basin bottom, probably due to straining over the stormwater infiltration stage. Particle-size analyses also indicate that retention of bigger SP led to faster straining of smaller SP, despite the small fraction of bigger SP. The clogging layer weakened the hydraulic connection between the water level in the basin and the water table of the unconfined aquifer until nearly no water could infiltrate into the aquifer. The deposition of finer SP that entered into the aquifer are governed by the hydrodynamic forces. These finer SP caused non-uniform permeability reduction of the porous medium, with an estimated 35% of permeability reduction occurring beneath the infiltration basin. However, the reduction appears to be reversible, as the fine SP deposited on the pore surfaces of the porous medium can be released or detached by the continuous horizontal hydraulic gradient. Extended tailing of the outlet breakthrough curve (BTC) also strongly supported the detachment of SP. This study focused on the effects of particles’ polydispersity and hydrodynamic forces on the hydraulic characteristics of the porous medium.
Collapse
|
23
|
Performance Assessment of a Laboratory Scale Prototype Biofiltration System in Tropical Region. SUSTAINABILITY 2019. [DOI: 10.3390/su11071947] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/16/2022]
Abstract
Biofiltration systems, as one of the best management practices, have good potentials to improve stormwater quality and hydrology of urban catchments. While biofiltration systems are well-studied in developed countries, the majority of those studies are conducted for temperate climate and there is a lack of lab-scale and field-scale studies on such systems under tropical conditions. This paper focuses on the performance of a lab-scale prototype biofiltration systems in stormwater retention efficiency as well as pollutants removal (including heavy metals and nutrients) from synthetic stormwater reproducing tropical rainfall events. A three-layer sand-based filter media with two different native plants including Pedilanthus tithymaloides and Cyperus alternifolius was selected for this study. Results showed that the system with Cyperus has a better stormwater retention capacity compared to the one with Pedilanthus. In addition, the observed infiltration rate in Cyperus and Pedilanthus were 338 mm/h and 267 mm/h, respectively. The better hydraulic performance in the system with Cyperus was attributed to the deeper and more extensive root penetration of this plant (as deep as 800 mm) compared to Pedilanthus (as deep as 250 mm). While both systems failed to perform well in removing total nitrogen, they performed significantly better in removing total phosphorus (Cyperus and Pedilanthus removed 67.3% and 62.5% of total phosphorus, respectively). The statistical analysis of results showed that the top 100 mm layer of filter media is the main contributor to total phosphorus removal. However, no major differences were observed between the two systems in phosphorus removal. Moreover, both systems were also capable of removing the available heavy metals (i.e., Fe, Cu, Mn, Ni, Pb, and Zn) as the removal efficiencies exceeded 90%, except for Fe (76%). Similar to phosphorus, it was concluded that the top layer is the major contributor to the heavy metals removal. Overall, the biofiltration system using Cyperus was found to be a successful system for operating under tropical conditions.
Collapse
|
24
|
Kim DG, Kang HM, Ko SO. Reduction of non-point source contaminants associated with road-deposited sediments by sweeping. ENVIRONMENTAL SCIENCE AND POLLUTION RESEARCH INTERNATIONAL 2019; 26:1192-1207. [PMID: 28929414 DOI: 10.1007/s11356-017-0192-y] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 12/15/2016] [Accepted: 09/12/2017] [Indexed: 06/07/2023]
Abstract
Road-deposited sediments (RDS) on an expressway, residual RDS collected after sweeping, and RDS removed by means of sweeping were analyzed to evaluate the degree to which sweeping removed various non-point source contaminants. The total RDS load was 393.1 ± 80.3 kg/km and the RDS, residual RDS, and swept RDS were all highly polluted with organics, nutrients, and metals. Among the metals studied, Cu, Zn, Pb, Ni, Ca, and Fe were significantly enriched, and most of the contaminants were associated with particles within the size range from 63 μm to 2 mm. Sweeping reduced RDS and its associated contaminants by 33.3-49.1% on average. We also measured the biological oxygen demand (BOD) of RDS in the present work, representing to our knowledge the first time that this has been done; we found that RDS contains a significant amount of biodegradable organics and that the reduction of BOD by sweeping was higher than that of other contaminants. Significant correlations were found between the contaminants measured, indicating that the organics and the metals originated from both exhaust and non-exhaust particles. Meanwhile, the concentrations of Cu and Ni were higher in 63 μm-2 mm particles than in smaller particles, suggesting that some metals in RDS likely exist intrinsically in particles, rather than only as adsorbates on particle surfaces. Overall, the results in this study showed that sweeping to collect RDS can be a good alternative for reduction of contaminants in runoff.
Collapse
Affiliation(s)
- Do-Gun Kim
- Department of Civil Engineering, Kyung Hee University, Yongin, Korea
| | - Hee-Man Kang
- Construction and Environment Research Division, Expressway and Transportation Research Institute, Korea Expressway Corporation, Hwaseong, Korea
| | - Seok-Oh Ko
- Department of Civil Engineering, Kyung Hee University, Yongin, Korea.
| |
Collapse
|
25
|
Assessing the Feasibility of Soil Infiltration Trenches for Highway Runoff Control on the Island of Oahu, Hawaii. WATER 2018. [DOI: 10.3390/w10121832] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/17/2022]
Abstract
The coastal waters of Hawaii are extremely important for recreation as well as for the health of the marine environment. Non-point source pollution from storm runoff poses a great threat to surface water quality in Hawaii. The State of Hawaii Department of Transportation (HDOT) includes infiltration trenches as a best management practice (BMP) option to reduce pollution caused by stormwater runoff. HDOT guidelines state that the implementation of BMPs is needed to reduce sediment and pollutant loads to streams and the ocean. In this study, the suitability of soils adjacent to highways on Oahu for the siting of infiltration trenches was examined. In addition to field surveys and in-situ tests, laboratory investigations on soil properties, infiltration experiments on undisturbed soil columns, and mathematical modeling of hydraulic functioning of the infiltration trench were conducted. Dissolved metal concentrations in highway stormwater runoff were observed to exceed the groundwater environmental action levels for all heavy metals tested, but the soils had high sorption capacity for these metals. The results of the simulations indicated that all the sampled Oahu soils, with one exception, would require less than two hours to drain a filled hypothetical trench. Therefore, these soils are suitable for construction of infiltration trenches as a possible BMP, even when clogging of soil is considered in the simulation.
Collapse
|
26
|
Reconstruction of Water Infiltration Rate Reducibility in Response to Suspended Solid Characteristics Using Singular Spectrum Analysis: An Application to the Caspian Sea Coast of Nur, Iran. HYDROLOGY 2018. [DOI: 10.3390/hydrology5040059] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/16/2022]
Abstract
Drawing a distinction between the suspended solid size and concentration impacts on physical clogging process in the Managed Aquifer Recharge (MAR) systems has been fraught with difficulties. Therefore, the current study was then aimed to statistically investigate and differentiate the impacts of clay-, silt- and sand-sized suspended solids at three concentration levels including 2, 5 and 10 g/L, compared with the clean water (0 g/L), on infiltration rate reducibility. The treatments were compared by virtue of Cohen’s d effect size measure. Furthermore, the competency of Singular Spectrum Analysis (SSA) was evaluated in reconstruction of infiltration rate. Results showed that clay-sized suspended solids were found to be the most important determining factor in physical clogging occurrence. The effect size measure highlighted that a lower concentration level of clay-sized suspended solids, that is, 2 g/L could be more important in trigging the physical clogging than a higher concentration level of silt-sized suspended solids namely 5 g/L. Also, we recognized that concentration level of clay-sized suspended sediments could non-linearly decrease the infiltrability. Also, findings revealed that SSA represented a high level of competency in reconstruction of the infiltration rate under all treatments. Hence, SSA can be quite beneficial to MAR systems for forecasting applications.
Collapse
|
27
|
Cui X, Chen C, Sun S, Zhou D, Ndayisenga F, Huo M, Zhu S, Zhang L, Crittenden JC. Acceleration of saturated porous media clogging and silicon dissolution due to low concentrations of Al(III) in the recharge of reclaimed water. WATER RESEARCH 2018; 143:136-145. [PMID: 29945029 DOI: 10.1016/j.watres.2018.06.043] [Citation(s) in RCA: 12] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 02/05/2018] [Revised: 05/10/2018] [Accepted: 06/18/2018] [Indexed: 06/08/2023]
Abstract
The recharge of reclaimed water is an effective strategy for addressing the issues of water quality deterioration and groundwater level decline simultaneously. Residual Al coagulants are normally remained in the recovered water at low concentrations, and may induce clogging problems during the recharging process. However, this issue has been ignored in the past. In this study, we investigated the mechanisms of Al(III)-induced aquifer bio-clogging, the role of Al(III) in quartz sand media (SiO2) dissolution and re-precipitation in the series of aquifer columns. We determined that Al(III) resulted in serious clogging in ∼140 h at low concentrations that satisfied the national drinking water standard of China. The corresponding hydraulic conductivity decreased by more than ∼90% in the bacteria-containing aquifer, which was ∼30% greater than that for the bacteria-free trials. The enhanced Al(III)-related clogging was caused by modifying quartz sand to form Si-O-Al(OH)n and improving microbes attachment. Microbes retention kinetic coefficients (k) of the Al recharged simulated aquifer could increase by 3.0-8.3 times. The Al(III) also enhanced biomass production and clogging by binding to microbial extracellular polymeric substances. In turn, the greater amount of biomass accelerated the Si dissolution and re-precipitation, this may potentially damage the stability of aquifer structure. The results showed that reclaimed water treated with Al coagulation should be employed with caution for recharging.
Collapse
Affiliation(s)
- Xiaochun Cui
- School of Environment, Northeast Normal University, Changchun 130117, China; Jilin Engineering Lab for Water Pollution Control and Resources Recovery, Northeast Normal University, Changchun 130117, China
| | - Congli Chen
- School of Environment, Northeast Normal University, Changchun 130117, China
| | - Shu Sun
- School of Environment, Northeast Normal University, Changchun 130117, China
| | - Dandan Zhou
- School of Environment, Northeast Normal University, Changchun 130117, China; Jilin Engineering Lab for Water Pollution Control and Resources Recovery, Northeast Normal University, Changchun 130117, China.
| | - Fabrice Ndayisenga
- School of Environment, Northeast Normal University, Changchun 130117, China
| | - Mingxin Huo
- School of Environment, Northeast Normal University, Changchun 130117, China
| | - Suiyi Zhu
- School of Environment, Northeast Normal University, Changchun 130117, China; Jilin Engineering Lab for Water Pollution Control and Resources Recovery, Northeast Normal University, Changchun 130117, China.
| | - Leilei Zhang
- School of Environment, Northeast Normal University, Changchun 130117, China
| | - John C Crittenden
- Brook Byers Institute for Sustainable Systems, Georgia Institute of Technology, Atlanta, GA 30332, USA; School of Civil & Environmental Engineering, Georgia Institute of Technology, Atlanta, GA 30332, USA
| |
Collapse
|
28
|
Quantitative Detection of Clogging in Horizontal Subsurface Flow Constructed Wetland Using the Resistivity Method. WATER 2018. [DOI: 10.3390/w10101334] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/16/2022]
Abstract
Substrate clogging seriously affects the lifetime and treatment performance of subsurface flow constructed wetlands (SSF CWs), and the quantitative detection of clogging is the key challenge in the management of substrate clogging. This paper explores the feasibility of the resistivity method to detect the clogging degree of an SSF CW. The clogged substrate was found to have a high water-holding capacity, which led to low apparent resistivity in the draining phase. On the basis of the resistivity characteristics, clogging quantification was performed with a standard laboratory procedure, i.e., the Wenner method used in a Miller Soil Box. The apparent resistivity to sediment fraction (v/v) (ARSF) model was established to evaluate the degree of clogging from the apparent resistivity. The results showed that the ARSF model fit well with the actual values (linear slope = 0.986; R-squared = 0.98). The methods for in situ resistivity detection were applied in a lab-scale horizontal subsurface flow constructed wetland (HSSF CW). Combined with the ARSF model, the two-probe method demonstrated high accuracy for clogging quantification (relative error less than 9%). These results suggest that the resistivity method is a reliable and feasible technique for in situ detection of clogging in SSF CWs.
Collapse
|
29
|
Engineering Analysis of Plant and Fungal Contributions to Bioretention Performance. WATER 2018. [DOI: 10.3390/w10091226] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/16/2022]
Abstract
While the use of bioretention for stormwater management is widespread, data about the impacts of plants and microorganisms on long-term treatment efficacy remain region-specific. To help address this knowledge gap for the Pacific Northwest region of the United States, we installed twelve under-drained bioretention mesocosms built to Washington State Department of Ecology stormwater management standards in an urban watershed in Seattle, WA that included a busy portion of Interstate 5. Six mesocosms were planted with Pacific ninebark (Physocarpus capitatus) and six were inoculated with the wine cap mushroom (Stropharia rugoso-annulata) resulting in four replicated factorial treatments. Because region-specific studies must be mindful of the prevailing regulatory framework, all mesocosms used the Washington State Department of Ecology design standard soil: a blend of 60% sand and 40% compost by volume, despite the known leaching problems with high compost volume fraction soils. Five water quality sampling events over 15 months of continuous stormwater loading were analyzed for dozens of water quality parameters. Multiple linear regression analyses of treatment differences over the 400-day loading period illustrate that incorporating fungi into the wood mulch slowed the release of total and ortho-phosphorus from the bioretention soil; however net export of phosphorus from this compost rich media continued through 400 days of loading for all treatments. Multivariate ordination methods illustrate that time and temperature dramatically affect performance of this media, but the impact of planting and fungal inoculation had marginal detectible effects on overall water quality during the study timeframe. These results demonstrate that future studies of this media blend must plan for at least one year of nutrient and metal leaching before the time-dependent heterogenous variance introduced by these exports will no longer pose an obstacle to analysis of other performance changing factors. The results highlight important physical and chemical considerations for this media blend, and the opportunity for continued research on the use of fungal inoculated mulch application as a new ecological engineering tool for reducing phosphorus leaching from soils.
Collapse
|
30
|
Clogging Impacts on Distribution Pipe Delivery of Street Runoff to an Infiltration Bed. WATER 2018. [DOI: 10.3390/w10081045] [Citation(s) in RCA: 14] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/17/2022]
Abstract
The performance of flow through orifices on a perforated distribution pipe between periods with and without partial clogging (submersion of part of the distribution pipe) was compared. The distribution pipe receives runoff and delivers it to an underground infiltration bed. Clogging appeared in winter but was reduced in summer. Performance of flow delivery was found to be defined by the effective pipe length and the pressure head. ANCOVA (ANalysis of COVAriance) was used to examine the clogging effect with flow rate plotted against the effective pipe length times the square root of the mean pressure head, and found that it was significant during low or no rainfall. During larger storms, clogging had little effect on pipe performance. Clogging might be caused by leaves and other trash accumulating in the lower section of the pipe in winter and its effect was insignificant when the water level rose in the pipe, utilizing significantly more orifices on the distribution pipe. Larger storms might also move the debris, thus exposing the orifices. The current maintenance schedule was sufficient to keep the distribution pipe at a satisfactory performance even though partial clogging can exist.
Collapse
|
31
|
Zhao Y, Huang L, Chen Y. Nitrogen and phosphorus removed from a subsurface flow multi-stage filtration system purifying agricultural runoff. ENVIRONMENTAL TECHNOLOGY 2018; 39:1715-1720. [PMID: 28562188 DOI: 10.1080/09593330.2017.1337233] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 11/07/2016] [Accepted: 05/26/2017] [Indexed: 06/07/2023]
Abstract
UNLABELLED Agricultural nonpoint source pollution has been increasingly serious in China since the 1990s. The main causes were excessive inputs of nitrogen fertilizer and pesticides. A multi-stage filtration system was built to test the purification efficiencies and removal characteristics of nitrogen and phosphorus when treating agricultural runoff. Simulated runoff pollution was prepared by using river water as source water based on the monitoring of local agricultural runoff. Experimental study had been performed from September to November 2013, adopting 12 h for flooding and 12 h for drying. The results showed that the system was made adaptive to variation of inflow quality and quantity, and had good removal for dissolved total nitrogen, total nitrogen, dissolved total phosphorus (DTP), and total phosphorus, and the average removal rate was 27%, 36%, 32%, and 48%, respectively. Except nitrate ([Formula: see text]), other forms of nitrogen and phosphorus all decreased with the increase of stages. Nitrogen was removed mainly in particle form the first stage, and mostly removed in dissolved form the second and third stage. Phosphorus was removed mainly in particulate during the first two stages, but the removal of particulate phosphorus and DTP were almost the same in the last stage. An approximate logarithmic relationship between removal loading and influent loading to nitrogen and phosphorus was noted in the experimental system, and the correlation coefficient was 0.78-0.94. ABBREVIATIONS [Formula: see text]: ammonium; [Formula: see text]: nitrite; [Formula: see text]: nitrate; DTN: dissolved total nitrogen; TN: total nitrogen; DTP: dissolved total phosphorus; TP: total phosphorus; PN: particulate nitrogen; PP: particulate phosphorus.
Collapse
Affiliation(s)
- Yaqi Zhao
- a Key Laboratory of the Three Gorges Reservoir Region's Eco-Environment (Ministry of Education), College of Resource and Environment , Southwest University , Chongqing , People's Republic of China
- b Chongqing Key Laboratory of Agricultural Resources and Environment , Chongqing , People's Republic of China
| | - Lei Huang
- a Key Laboratory of the Three Gorges Reservoir Region's Eco-Environment (Ministry of Education), College of Resource and Environment , Southwest University , Chongqing , People's Republic of China
- b Chongqing Key Laboratory of Agricultural Resources and Environment , Chongqing , People's Republic of China
| | - Yucheng Chen
- a Key Laboratory of the Three Gorges Reservoir Region's Eco-Environment (Ministry of Education), College of Resource and Environment , Southwest University , Chongqing , People's Republic of China
- b Chongqing Key Laboratory of Agricultural Resources and Environment , Chongqing , People's Republic of China
| |
Collapse
|
32
|
Alam MZ, Anwar AHMF, Heitz A. Stormwater solids removal characteristics of a catch basin insert using geotextile. THE SCIENCE OF THE TOTAL ENVIRONMENT 2018; 618:1054-1063. [PMID: 29108695 DOI: 10.1016/j.scitotenv.2017.09.091] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 07/07/2017] [Revised: 09/08/2017] [Accepted: 09/10/2017] [Indexed: 06/07/2023]
Abstract
Suspended solids in urban runoff have multiple adverse environmental impacts and create a wide range of water quality problems in receiving water bodies. Geotextile filtration systems inserted within catch basins have the potential to mitigate these effects, through flow attenuation and pollutant removal. This study modelled a catch basin in a column and assessed the hydraulic and solids removal characteristics of a new type of non-woven geotextile (NWG1) in the capture of solids from stormwater runoff. The new geotextile was compared with two others readily available on the market (NWG2, NWG3). Synthetic stormwater containing TSS (200mg/L) was used with two particle size distributions of 0-180μm (P1; D50:106μm) and 0-300μm (P2; D50:150μm). The results revealed that the desired stormwater TSS concentration (<30mg/L; ANZECC, 2000) could be achieved with a short ripening process (e.g., 1-2kg/m2 of suspended solids loading) for trials using the larger particle size distribution (P2). In addition, 36% more suspended solids were captured in trials using the soil with the larger range of particle sizes (P2) than for the soil with smaller particle sizes (P1). Geotextile fibre pattern appeared to have a significant influence on the TSS removal capacity. The NWG1 has higher permittivity than NWG3 but similar to NWG2. NWG1 could capture overall more TSS (which also resulted in earlier clogging) than NWG2 and NWG3 because of the special fibre structure of NWG1. The experimental data shows that these geotextiles may start to clog when the hydraulic conductivity reaches below 1.36×10-5m/s. The overall hydraulic performances of geotextiles showed that the NWG1 has better potential for use in CBIs because of its higher strength and multiple reuse capability.
Collapse
Affiliation(s)
- Md Zahanggir Alam
- Department of Civil Engineering, Curtin University, GPO Box U1987, Perth, WA 6845, Australia.
| | - A H M Faisal Anwar
- Department of Civil Engineering, Curtin University, GPO Box U1987, Perth, WA 6845, Australia
| | - Anna Heitz
- Department of Civil Engineering, Curtin University, GPO Box U1987, Perth, WA 6845, Australia
| |
Collapse
|
33
|
Sihag P, Jain P, Kumar M. Modelling of impact of water quality on recharging rate of storm water filter system using various kernel function based regression. ACTA ACUST UNITED AC 2018. [DOI: 10.1007/s40808-017-0410-0] [Citation(s) in RCA: 49] [Impact Index Per Article: 8.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/18/2022]
|
34
|
Fetzer J, Holzner M, Plötze M, Furrer G. Clogging of an Alpine streambed by silt-sized particles - Insights from laboratory and field experiments. WATER RESEARCH 2017; 126:60-69. [PMID: 28918079 DOI: 10.1016/j.watres.2017.09.015] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 03/27/2017] [Revised: 08/24/2017] [Accepted: 09/04/2017] [Indexed: 06/07/2023]
Abstract
Clogging of streambeds by suspended particles (SP) can cause environmental problems, as it can negatively influence, e.g., habitats for macrozoobenthos, fish reproduction and groundwater recharge. This especially applies in the case of silt-sized SP. Until now, most research has dealt with coarse SP and was carried out in laboratory systems. The aims of this study are to examine (1) whether physical clogging by silt-sized SP exhibits the same dynamics and patterns as by sand-sized SP, and (2) the comparability of results between laboratory and field experiments. We carried out vertical column experiments with sand-sized bed material and silt-sized SP, which are rich in mica minerals. In laboratory experiments, we investigated the degree of clogging quantified by the reduction of porosity and hydraulic conductivity and the maximum clogging depth as a function of size and shape of bed material, size of SP, pore water flow velocity, and concentration of calcium cations. The SP were collected from an Alpine sedimentation basin, where our field experiments were carried out. To investigate the clogging process in the field, we buried columns filled with sand-sized quartz in the stream bed. We found that the maximal bed-to-grain ratio where clogging still occurs is larger for silt-sized SP than for sand-sized SP. The observed clogging depths and the reduction of flow rate through the column from our laboratory experiments were comparable to those from the field. However, our field results showed that the extent of clogging strongly depends on the naturally-occurring hydrological dynamics. The field location was characterized by a more polydisperse suspension, a strongly fluctuating water regime, and high SP concentrations at times, leading to more heterogeneous and more pronounced clogging when compared to laboratory results.
Collapse
Affiliation(s)
- Jasmin Fetzer
- ETH Zurich, Institute of Biogeochemistry and Pollutant Dynamics, 8092 Zürich, Switzerland.
| | - Markus Holzner
- ETH Zurich, Institute of Environmental Engineering, 8093 Zürich, Switzerland.
| | - Michael Plötze
- ETH Zurich, Institute for Geotechnical Engineering, 8093 Zürich, Switzerland.
| | - Gerhard Furrer
- ETH Zurich, Institute of Biogeochemistry and Pollutant Dynamics, 8092 Zürich, Switzerland.
| |
Collapse
|
35
|
A Laboratory Study on the Filtration and Clogging of the Sand-Bottom Ash Mixture for Stormwater Infiltration Filter Media. WATER 2017. [DOI: 10.3390/w9010032] [Citation(s) in RCA: 20] [Impact Index Per Article: 2.9] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/16/2022]
|
36
|
Adugna D, Larsen L, Lemma B, Sahilu G. Low-Cost Stormwater Filtration System to Improve Urban Water Quality: The Case of Addis Ababa, Ethiopia. ACTA ACUST UNITED AC 2017. [DOI: 10.4236/jwarp.2017.96046] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/20/2022]
|
37
|
Segismundo EQ, Lee BS, Kim LH, Koo BH. Evaluation of the Impact of Filter Media Depth on Filtration Performance and Clogging Formation of a Stormwater Sand Filter. ACTA ACUST UNITED AC 2016. [DOI: 10.15681/kswe.2016.32.1.36] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/12/2022]
|
38
|
Subramaniam DN, Mather PB. Preliminary stabilisation of stormwater biofilters and loss of filter material. WATER SCIENCE AND TECHNOLOGY : A JOURNAL OF THE INTERNATIONAL ASSOCIATION ON WATER POLLUTION RESEARCH 2016; 74:787-795. [PMID: 27533853 DOI: 10.2166/wst.2016.256] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/06/2023]
Abstract
Stabilisation affects performance of stormwater biofilters operating under intermittent wetting and drying, mainly due to wash-off of filter material. Understanding the dynamics of solids wash-off is crucial in designing stormwater biofilters. The current study analysed the dynamics of solids wash-off in stormwater biofilters and quantified the loss of solids from the filter. Four Perspex™ bioretention columns (94 mm internal diameter) were fabricated with a filter layer that contained 8% organic material and were fed with tap water with different numbers of antecedent dry days (0-40 day) at 100 mL/min. Samples were collected from the outflow and tested for particle size distribution and total solids and turbidity. Solids of particle size less than 50 microns were washed off from the filter during the stabilisation period, indicating that no sand particles were washed off. The very first event after commissioning the filter resulted in the highest wash-off of solids (approximately 75 g of fines) while a significant drop in wash-off followed from the second event. An empirical model fitted to the data showed that preliminary stabilisation of a filter occurs in the first three events, during which almost 25% of fines are lost from the filter.
Collapse
Affiliation(s)
- D N Subramaniam
- Faculty of Engineering, University of Jaffna, Ariviyal Nagar, Kilinochchi, Sri Lanka E-mail:
| | - P B Mather
- Queensland University of Technology, Brisbane, Australia
| |
Collapse
|
39
|
Kim DG, Kim HS, Kang HM, Ko SO. Pollutant characteristics of road deposited sediments collected by road sweeping. WATER SCIENCE AND TECHNOLOGY : A JOURNAL OF THE INTERNATIONAL ASSOCIATION ON WATER POLLUTION RESEARCH 2016; 74:194-202. [PMID: 27386997 DOI: 10.2166/wst.2016.198] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/06/2023]
Abstract
Road deposited sediments (RDS) swept from highways in South Korea were characterized to quantitatively evaluate the reduction in non-point source pollutants by sweeping. The swept RDS consisted primarily of sand (63 μm to 2 mm) particles (80.34 ± 8.33% of total weight) highly contaminated by organics, nutrients and heavy metals. The average concentrations of total organic carbon (TOC), biochemical oxygen demand (BOD), volatile solids (VS), total nitrogen (T-N), and total phosphorus (T-P) were 20.17 ± 9.13, 1.04 ± 0.62, 39.92 ± 16.55, 1.99 ± 0.96, and 0.54 ± 0.19 g kg(-1) (±one standard deviation), respectively, for 63 μm to 2 mm RDS. The concentrations of the pollutants were high for RDS smaller than 63 μm, but most of the mass was associated with the 63 μm to 2 mm RDS. The results suggest that the pollutants associated with RDS swept from highways originated mainly from engine wear, exhaust emissions, and tire wear. These results were different from the RDS on roads in residential and commercial areas, where natural particles and brake wear contribute significantly to RDS. In addition, the reductions in TOC, BOD, VS, T-N, T-P, Cu, Pb, Zn, Fe, and As based on the swept RDS measurements were calculated to be 3,355.3, 175.1, 6,621.4, 323.0, 88.3, 30.3, 13.7, 1.0, 303.4, 11,198.7, and 0.4 g km(-1), respectively.
Collapse
Affiliation(s)
- Do-Gun Kim
- Department of Civil Engineering, Kyung Hee University, Yongin, Korea E-mail:
| | - Hyun-Seop Kim
- Department of Civil Engineering, Kyung Hee University, Yongin, Korea E-mail:
| | - Hee-Man Kang
- Construction and Environment Research Division, Expressway & Transportation Research Institute, Hwaseong, Korea
| | - Seok-Oh Ko
- Department of Civil Engineering, Kyung Hee University, Yongin, Korea E-mail:
| |
Collapse
|
40
|
Sønderup MJ, Egemose S, Bochdam T, Flindt MR. Treatment efficiency of a wet detention pond combined with filters of crushed concrete and sand: a Danish full-scale study of stormwater. ENVIRONMENTAL MONITORING AND ASSESSMENT 2015; 187:758. [PMID: 26577218 DOI: 10.1007/s10661-015-4975-7] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 12/17/2014] [Accepted: 11/09/2015] [Indexed: 06/05/2023]
Abstract
Traditional wet detention ponds and sand filters remove particles efficiently, whereas only a minor part of the dissolved and bioavailable load is removed. To improve the retention of dissolved substances, we tested crushed concrete as a filter material simultaneously with a traditional sand filter placed after an existing wet pond. The particulate fractions (particles, organic matter, phosphorus, and heavy metals) were removed efficiently in the pond and both filter materials, with the concrete filter often being best seen over a year. Dissolved heavy metals (lead (Pb), nickel (Ni), copper (Cu), chromium (Cr), and cadmium (Cd)) were largely retained, though a washout was observed from the pond (Ni and Cu), concrete filter (Cr), and sand filter (Ni) during the first month. The pond only retained total dissolved phosphorus (TDP) during summer. Crushed concrete and sand had a high (>70%) retention of TDP within the first months of operation, but the retention dropped in both filters due to a large oil load into the system (4 kg impermeable ha(-1) in 1 month). The poor retention might to some degree be due to mineralization processes turning particulate phosphorus (PP) into TDP. The massive oil load was retained efficiently (99.3%) in the pond and both filters, clearly illustrating that both filter materials were able to retain either oil or TDP. An additional pilot study showed that at residence times of 1 h, crushed concrete bound 90% TDP whereas sand only bound 22% TDP. Retention of TDP and PP decreased with shorter residence time in both materials, but fastest in sand.
Collapse
Affiliation(s)
- Melanie J Sønderup
- Department of Biology, University of Southern Denmark, Campusvej 55, 5230, Odense M, Denmark.
- Arwos A/S, Forsyningsvejen 2, 6200, Aabenraa, Denmark.
| | - Sara Egemose
- Department of Biology, University of Southern Denmark, Campusvej 55, 5230, Odense M, Denmark
| | - Timm Bochdam
- Arwos A/S, Forsyningsvejen 2, 6200, Aabenraa, Denmark
| | - Mogens R Flindt
- Department of Biology, University of Southern Denmark, Campusvej 55, 5230, Odense M, Denmark
| |
Collapse
|
41
|
Mermillod-Blondin F, Simon L, Maazouzi C, Foulquier A, Delolme C, Marmonier P. Dynamics of dissolved organic carbon (DOC) through stormwater basins designed for groundwater recharge in urban area: Assessment of retention efficiency. WATER RESEARCH 2015; 81:27-37. [PMID: 26024961 DOI: 10.1016/j.watres.2015.05.031] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 12/08/2014] [Revised: 04/24/2015] [Accepted: 05/04/2015] [Indexed: 06/04/2023]
Abstract
Managed aquifer recharge (MAR) has been developed in many countries to limit the risk of urban flooding and compensate for reduced groundwater recharge in urban areas. The environmental performances of MAR systems like infiltration basins depend on the efficiency of soil and vadose zone to retain stormwater-derived contaminants. However, these performances need to be finely evaluated for stormwater-derived dissolved organic matter (DOM) that can affect groundwater quality. Therefore, this study examined the performance of MAR systems to process DOM during its transfer from infiltration basins to an urban aquifer. DOM characteristics (fluorescent spectroscopic properties, biodegradable and refractory fractions of dissolved organic carbon -DOC-, consumption by micro-organisms during incubation in slow filtration sediment columns) were measured in stormwater during its transfer through three infiltration basins during a stormwater event. DOC concentrations sharply decreased from surface to the aquifer for the three MAR sites. This pattern was largely due to the retention of biodegradable DOC which was more than 75% for the three MAR sites, whereas the retention of refractory DOC was more variable and globally less important (from 18% to 61% depending on MAR site). Slow filtration column experiments also showed that DOC retention during stormwater infiltration through soil and vadose zone was mainly due to aerobic microbial consumption of the biodegradable fraction of DOC. In parallel, measurements of DOM characteristics from groundwaters influenced or not by MAR demonstrated that stormwater infiltration increased DOC quantity without affecting its quality (% of biodegradable DOC and relative aromatic carbon content -estimated by SUVA254-). The present study demonstrated that processes occurring in soil and vadose zone of MAR sites were enough efficient to limit DOC fluxes to the aquifer. Nevertheless, the enrichments of DOC concentrations measured in groundwater below infiltration basins need to be considered in future studies to especially assess their impact on groundwater quality.
Collapse
Affiliation(s)
- Florian Mermillod-Blondin
- Université de Lyon, UMR 5023 Ecologie des Hydrosystèmes Naturels et Anthropisés, Université Lyon 1, CNRS, ENTPE, 6 Rue Raphaël Dubois, 69622 Villeurbanne, France.
| | - Laurent Simon
- Université de Lyon, UMR 5023 Ecologie des Hydrosystèmes Naturels et Anthropisés, Université Lyon 1, CNRS, ENTPE, 6 Rue Raphaël Dubois, 69622 Villeurbanne, France
| | - Chafik Maazouzi
- Université de Lyon, UMR 5023 Ecologie des Hydrosystèmes Naturels et Anthropisés, Université Lyon 1, CNRS, ENTPE, 6 Rue Raphaël Dubois, 69622 Villeurbanne, France
| | - Arnaud Foulquier
- Irstea, Groupement de Lyon, UR MALY, 5 rue de la Doua, 69626 Villeurbanne, France; Laboratoire d'Ecologie Alpine, UMR 5553, Université Grenoble Alpes, BP 53, 38041 Grenoble, France
| | - Cécile Delolme
- Université de Lyon, UMR 5023 Ecologie des Hydrosystèmes Naturels et Anthropisés, Université Lyon 1, CNRS, ENTPE, 6 Rue Raphaël Dubois, 69622 Villeurbanne, France
| | - Pierre Marmonier
- Université de Lyon, UMR 5023 Ecologie des Hydrosystèmes Naturels et Anthropisés, Université Lyon 1, CNRS, ENTPE, 6 Rue Raphaël Dubois, 69622 Villeurbanne, France
| |
Collapse
|
42
|
Binet S, Bru K, Klinka T, Touzé S, Motelica-Heino M. Water and acrylamide monomer transfer rates from a settling basin to groundwaters. ENVIRONMENTAL SCIENCE AND POLLUTION RESEARCH INTERNATIONAL 2015; 22:6431-6439. [PMID: 24903251 DOI: 10.1007/s11356-014-3106-2] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 02/28/2014] [Accepted: 05/26/2014] [Indexed: 06/03/2023]
Abstract
The aim of this paper was to estimate the potential leakage of acrylamide monomer, used for flocculation in a settling basin, towards the groundwaters. Surface-groundwater interactions were conceptualized with a groundwater transport model, using a transfer rate to describe the clogged properties of the interface. The change in the transfer rate as a function of the spreading of the clogged layer in the settling basin was characterized with respect to time. It is shown that the water and the Acrylamide transfer rate are not controlled by the spreading of the clogged layer until this layer fully covers the interface. When the clogged layer spreads out, the transfer rate remains in the same order of magnitude until the area covered reaches 80 %. The main flux takes place through bank seepage. In these early stage conditions of a working settling basin, the acrylamide flux towards groundwaters remains constant, at close to 10 g/year (±5).
Collapse
Affiliation(s)
- Stéphane Binet
- CNRS; UPS; INP; UMR 5245; Laboratoire Ecologie Fonctionnelle et Environnement (EcoLab), Université de Toulouse, ENSAT, Avenue de l'Agrobiopole, 31326, Castanet Tolosan, France,
| | | | | | | | | |
Collapse
|
43
|
Lim HS, Lim W, Hu JY, Ziegler A, Ong SL. Comparison of filter media materials for heavy metal removal from urban stormwater runoff using biofiltration systems. JOURNAL OF ENVIRONMENTAL MANAGEMENT 2015; 147:24-33. [PMID: 25261749 DOI: 10.1016/j.jenvman.2014.04.042] [Citation(s) in RCA: 20] [Impact Index Per Article: 2.2] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 12/28/2013] [Revised: 04/16/2014] [Accepted: 04/22/2014] [Indexed: 06/03/2023]
Abstract
The filter media in biofiltration systems play an important role in removing potentially harmful pollutants from urban stormwater runoff. This study compares the heavy metal removal potential (Cu, Zn, Cd, Pb) of five materials (potting soil, compost, coconut coir, sludge and a commercial mix) using laboratory columns. Total/dissolved organic carbon (TOC/DOC) was also analysed because some of the test materials had high carbon content which affects heavy metal uptake/release. Potting soil and the commercial mix offered the best metal uptake when dosed with low (Cu: 44.78 μg/L, Zn: 436.4 μg/L, Cd, 1.82 μg/L, Pb: 51.32 μg/L) and high concentrations of heavy metals (Cu: 241 μg/L, Zn: 1127 μg/L, Cd: 4.57 μg/L, Pb: 90.25 μg/L). Compost and sludge also had high removal efficiencies (>90%). Heavy metal leaching from these materials was negligible. A one-month dry period between dosing experiments did not affect metal removal efficiencies. TOC concentrations from all materials increased after the dry period. Heavy metal removal was not affected by filter media depth (600 mm vs. 300 mm). Heavy metals tended to accumulate at the upper 5 cm of the filter media although potting soil showed bottom-enriched concentrations. We recommend using potting soil as the principal media mixed with compost or sludge since these materials perform well and are readily available. The use of renewable materials commonly found in Singapore supports a sustainable approach to urban water management.
Collapse
Affiliation(s)
- H S Lim
- Department of Geography, National University of Singapore, 117570 Singapore, Singapore.
| | - W Lim
- Department of Civil & Environmental Engineering, National University of Singapore, 117576 Singapore, Singapore
| | - J Y Hu
- Department of Civil & Environmental Engineering, National University of Singapore, 117576 Singapore, Singapore; NUS Environmental Research Institute, National University of Singapore, 117411 Singapore, Singapore
| | - A Ziegler
- Department of Geography, National University of Singapore, 117570 Singapore, Singapore
| | - S L Ong
- Department of Civil & Environmental Engineering, National University of Singapore, 117576 Singapore, Singapore; NUS Environmental Research Institute, National University of Singapore, 117411 Singapore, Singapore
| |
Collapse
|
44
|
Vesting A, Heinz E, Helmreich B, Wichern M. Removal of hydrocarbons from synthetic road runoff through adsorptive filters. WATER SCIENCE AND TECHNOLOGY : A JOURNAL OF THE INTERNATIONAL ASSOCIATION ON WATER POLLUTION RESEARCH 2015; 72:802-809. [PMID: 26287840 DOI: 10.2166/wst.2015.285] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/04/2023]
Abstract
Compact filter systems, which are installed to significantly reduce the load of pollutants from road runoff, are very promising treatments for urban runoff. The objective of this research was to evaluate the effectiveness of activated carbon, activated lignite, zero valent iron, exfoliated graphite, amorphous ferric hydroxide, and activated alumina at removing petrol hydrocarbons from synthetic road runoff. Therefore, the kinetics and the equilibrium adsorption of petrol hydrocarbons onto these adsorbents were investigated using column adsorption experiments at levels ranging from 100 to 42 g L(-1). Of the tested adsorbents, exfoliated graphite is the most effective with a maximum adsorption capacity for petrol hydrocarbons of 3,850 mg g(-1). The experimental equilibrium data are fitted to the Freundlich and Langmuir models.
Collapse
Affiliation(s)
- Andreas Vesting
- Institute of Urban Water Management and Environmental Engineering, Ruhr-Universität Bochum, Universitätsstraße 150, 44780 Bochum, Germany E-mail:
| | - Eva Heinz
- Institute of Urban Water Management and Environmental Engineering, Ruhr-Universität Bochum, Universitätsstraße 150, 44780 Bochum, Germany E-mail:
| | - Brigitte Helmreich
- Chair of Urban Water Systems Engineering, Technische Universität München, Am Coulombwall 8, 85748 Garching, Germany
| | - Marc Wichern
- Institute of Urban Water Management and Environmental Engineering, Ruhr-Universität Bochum, Universitätsstraße 150, 44780 Bochum, Germany E-mail:
| |
Collapse
|
45
|
Using Drainage Slots in Permeable Paving Blocks to Delay the Effects of Clogging: Proof of Concept Study. WATER 2014. [DOI: 10.3390/w6092660] [Citation(s) in RCA: 10] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/17/2022]
|
46
|
Kim DG, Jeong K, Ko SO. Removal of road deposited sediments by sweeping and its contribution to highway runoff quality in Korea. ENVIRONMENTAL TECHNOLOGY 2014; 35:2546-55. [PMID: 25145210 DOI: 10.1080/09593330.2014.911777] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/22/2023]
Abstract
Highway runoff is known to be an important non-point source (NPS), increasing the load of pollutants in receiving water. For reducing NPS pollutants in runoff, removal of road deposited sediment (RDS) by sweeping is considered effective. However, the contribution of sweeping to the improvement of runoff quality has not been clearly and quantitatively demonstrated so far. In this study, a field test was carried out on a section of operating highway in Korea to investigate the effectiveness of sweeping on improving the quality of highway runoff. Results showed that the average reduction in the load of RDS by sweeping was 61.10% with a standard deviation of 1.74%. RDS removal efficiency decreased when the sweeping speed increased from 4-8 to 20 km h(-1), the load decreased from 12.5 to 1.25 g m(-2) and particle size decreased from sand to silt/clay size ranges. Runoff was induced by applying a 15 mm h(-1) artificial rainfall to both swept and non-swept sections. Analysis of runoff quality showed that the event mean concentrations of total suspended solid, biological oxygen demand, chemical oxygen demand, nutrients and most of the heavy metals were reduced by 31-87% after sweeping. In addition, field tests for RDS build-up indicated a sweeping frequency of once every four or five days to prevent re-suspension of RDS. The results of this study suggest that sweeping can be the best management practice for effectively reducing RDS on highways and improving the quality of highway runoff.
Collapse
|
47
|
The Prediction Methods for Potential Suspended Solids Clogging Types during Managed Aquifer Recharge. WATER 2014. [DOI: 10.3390/w6040961] [Citation(s) in RCA: 23] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/17/2022]
|
48
|
Singh RP, Fu D, Fu D, Juan H. Pollutant Removal Efficiency of Vertical Sub-surface Upward Flow Constructed Wetlands for Highway Runoff Treatment. ARABIAN JOURNAL FOR SCIENCE AND ENGINEERING 2014. [DOI: 10.1007/s13369-014-1029-3] [Citation(s) in RCA: 13] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/29/2022]
|
49
|
Coleri E, Kayhanian M, Harvey JT, Yang K, Boone JM. Clogging evaluation of open graded friction course pavements tested under rainfall and heavy vehicle simulators. JOURNAL OF ENVIRONMENTAL MANAGEMENT 2013; 129:164-172. [PMID: 23920417 DOI: 10.1016/j.jenvman.2013.07.005] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 03/14/2013] [Revised: 07/02/2013] [Accepted: 07/07/2013] [Indexed: 06/02/2023]
Abstract
In this study a new procedure is developed to obtain core samples from field sections to assess clogging mechanisms of open graded friction course (OGFC) pavements using X-ray computed tomography (CT) imaging. The approach compared X-ray computed tomography (CT) images taken before and after: (1) rainfall simulations without trafficking to investigate particle-related clogging and (2) full-scale accelerated pavement rutting tests (APT) to investigate deformation related clogging of OGFC layers. Rainfall simulations were performed with runoff water of known total suspended solids (TSS) and particle size distributions (PSDs). Full-scale accelerated rutting tests were performed under controlled temperature and loads. Both investigations were performed for three different OGFC pavements with different layer thicknesses and mix types. The clogging of rutting test sections were also evaluated by comparing the surface permeability measurements performed before and after APT testing. The results of X-ray CT image processing revealed a significant reduction in air-void content of core samples after APT rutting tests. The highest air-void reduction was concentrated at the bottom of the OGFC layers. Permeability measurements also showed a 40%-90% reduction in permeability after APT trafficking. X-ray CT image processing of core samples tested under simulated rainfall showed that air void content reduction is concentrated in the lower part (2-6 mm from the bottom) of the OGFC layers as a result of particle accumulation. Small changes in air void contents were observed in the upper part of the OGFC layers (10-15 mm) while these reductions in air void contents were not significant to cause surface overflow and hence it is expected that the tested OGFC pavements will have sufficient permeability to infiltrate water during most average storm events.
Collapse
Affiliation(s)
- Erdem Coleri
- University of California Pavement Research Center, Department of Civil and Environmental Engineering, One Shields Avenue, Ghausi Hall, University of California, Davis, CA 95616, USA.
| | | | | | | | | |
Collapse
|
50
|
Hilliges R, Schriewer A, Helmreich B. A three-stage treatment system for highly polluted urban road runoff. JOURNAL OF ENVIRONMENTAL MANAGEMENT 2013; 128:306-312. [PMID: 23770438 DOI: 10.1016/j.jenvman.2013.05.024] [Citation(s) in RCA: 23] [Impact Index Per Article: 2.1] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 10/15/2012] [Revised: 03/01/2013] [Accepted: 05/08/2013] [Indexed: 06/02/2023]
Abstract
A three-stage treatment device for polluted urban road runoff was installed and tested at a highly trafficked urban road over a period of one year. In the first stage coarse material and particles from the runoff are removed by a special gutter system. The second stage eliminates particles using a hydrodynamic separator. In the third stage dissolved pollutants are adsorbed in a filter unit with lignite as filter material. Twenty-four rain events were sampled over the one year period and analyzed for dissolved and particulate copper (Cu), zinc (Zn), lead (Pb), suspended solids (SS), total organic carbon (TOC), sodium (Na), and pH value. The treatment system was able to safely retain all relevant pollutants during the investigated period, except Na. In the effluent of the treatment device Pb could never be detected, values measured for Zn were in the range of the detection limit. Cu, the element most frequently detected in the effluent, never exceeded the critical value of 50 μg/L set by the German Federal Soil Protection Act and Ordinance. The median Cu concentration in the effluent of the treatment system was 8.13 μg/L. The treatment system proved to be very effective. Highly polluted road runoff can be purified by the system to an extent that no contamination risk for soil and groundwater remains when infiltrated into the soil.
Collapse
Affiliation(s)
- Rita Hilliges
- University of Applied Science Augsburg, An der Hochschule 1, 86161 Augsburg, Germany
| | | | | |
Collapse
|