1
|
Zhao L, Guzman HP, Xagoraraki I. Comparative analyses of SARS-CoV-2 RNA concentrations in Detroit wastewater quantified with CDC N1, N2, and SC2 assays reveal optimal target for predicting COVID-19 cases. THE SCIENCE OF THE TOTAL ENVIRONMENT 2024; 945:174140. [PMID: 38906283 DOI: 10.1016/j.scitotenv.2024.174140] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 03/17/2024] [Revised: 06/10/2024] [Accepted: 06/17/2024] [Indexed: 06/23/2024]
Abstract
To monitor COVID-19 through wastewater surveillance, global researchers dedicated significant endeavors and resources to develop and implement diverse RT-qPCR or RT-ddPCR assays targeting different genes of SARS-CoV-2. Effective wastewater surveillance hinges on the appropriate selection of the most suitable assay, especially for resource-constrained regions where scant technical and socioeconomic resources restrict the options for testing with multiple assays. Further research is imperative to evaluate the existing assays through comprehensive comparative analyses. Such analyses are crucial for health agencies and wastewater surveillance practitioners in the selection of appropriate methods for monitoring COVID-19. In this study, untreated wastewater samples were collected weekly from the Detroit wastewater treatment plant, Michigan, USA, between January and December 2023. Polyethylene glycol precipitation (PEG) was applied to concentrate the samples followed by RNA extraction and RT-ddPCR. Three assays including N1, N2 (US CDC Real-Time Reverse Transcription PCR Panel for Detection of SARS-CoV-2), and SC2 assay (US CDC Influenza SARS-CoV-2 Multiplex Assay) were implemented to detect SARS-CoV-2 in wastewater. The limit of blank and limit of detection for the three assays were experimentally determined. SARS-CoV-2 RNA concentrations were evaluated and compared through three statistical approaches, including Pearson and Spearman's rank correlations, Dynamic Time Warping, and vector autoregressive models. N1 and N2 demonstrated the highest correlation and most similar time series patterns. Conversely, N2 and SC2 assay demonstrated the lowest correlation and least similar time series patterns. N2 was identified as the optimal target to predict COVID-19 cases. This study presents a rigorous effort in evaluating and comparing SARS-CoV-2 RNA concentrations quantified with N1, N2, and SC2 assays and their interrelations and correlations with clinical cases. This study provides valuable insights into identifying the optimal target for monitoring COVID-19 through wastewater surveillance.
Collapse
Affiliation(s)
- Liang Zhao
- Department of Civil and Environmental Engineering, Michigan State University, 1449 Engineering Research Ct., East Lansing, MI 48823, USA
| | - Heidy Peidro Guzman
- Department of Civil and Environmental Engineering, Michigan State University, 1449 Engineering Research Ct., East Lansing, MI 48823, USA
| | - Irene Xagoraraki
- Department of Civil and Environmental Engineering, Michigan State University, 1449 Engineering Research Ct., East Lansing, MI 48823, USA.
| |
Collapse
|
2
|
Bustin SA. RT-qPCR Testing and Performance Metrics in the COVID-19 Era. Int J Mol Sci 2024; 25:9326. [PMID: 39273275 PMCID: PMC11394961 DOI: 10.3390/ijms25179326] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/06/2024] [Revised: 08/23/2024] [Accepted: 08/26/2024] [Indexed: 09/15/2024] Open
Abstract
The COVID-19 pandemic highlighted the crucial role of diagnostic testing in managing infectious diseases, particularly through the use of reverse transcription-quantitative polymerase chain reaction (RT-qPCR) tests. RT-qPCR has been pivotal in detecting and quantifying viral RNA, enabling the identification and management of SARS-CoV-2 infections. However, despite its widespread use, there remains a notable gap in understanding fundamental diagnostic metrics such as sensitivity and specificity among many scientists and healthcare practitioners. This gap is not merely academic; it has profound implications for interpreting test results, making public health decisions, and affecting patient outcomes. This review aims to clarify the distinctions between laboratory- and field-based metrics in the context of RT-qPCR testing for SARS-CoV-2 and summarise the global efforts that led to the development and optimisation of these tests during the pandemic. It is intended to enhance the understanding of these fundamental concepts among scientists and healthcare professionals who may not be familiar with the nuances of diagnostic test evaluation. Such knowledge is crucial for accurately interpreting test results, making informed public health decisions, and ultimately managing infectious disease outbreaks more effectively.
Collapse
Affiliation(s)
- Stephen A Bustin
- Medical Technology Research Centre, Anglia Ruskin University, Chelmsford CM1 1SQ, UK
| |
Collapse
|
3
|
Länsivaara A, Lehto KM, Hyder R, Janhonen ES, Lipponen A, Heikinheimo A, Pitkänen T, Oikarinen S. Comparison of Different Reverse Transcriptase-Polymerase Chain Reaction-Based Methods for Wastewater Surveillance of SARS-CoV-2: Exploratory Study. JMIR Public Health Surveill 2024; 10:e53175. [PMID: 39158943 PMCID: PMC11369532 DOI: 10.2196/53175] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/28/2023] [Revised: 04/09/2024] [Accepted: 05/30/2024] [Indexed: 08/20/2024] Open
Abstract
BACKGROUND Many countries have applied the wastewater surveillance of the COVID-19 pandemic to their national public health monitoring measures. The most used methods for detecting SARS-CoV-2 in wastewater are quantitative reverse transcriptase-polymerase chain reaction (RT-qPCR) and reverse transcriptase-droplet digital polymerase chain reaction (RT-ddPCR). Previous comparison studies have produced conflicting results, thus more research on the subject is required. OBJECTIVE This study aims to compare RT-qPCR and RT-ddPCR for detecting SARS-CoV-2 in wastewater. It also aimed to investigate the effect of changes in the analytical pipeline, including the RNA extraction kit, RT-PCR kit, and target gene assay, on the results. Another aim was to find a detection method for low-resource settings. METHODS We compared 2 RT-qPCR kits, TaqMan RT-qPCR and QuantiTect RT-qPCR, and RT-ddPCR based on sensitivity, positivity rates, variability, and correlation of SARS-CoV-2 gene copy numbers in wastewater to the incidence of COVID-19. Furthermore, we compared 2 RNA extraction methods, column- and magnetic-bead-based. In addition, we assessed 2 target gene assays for RT-qPCR, N1 and N2, and 2 target gene assays for ddPCR N1 and E. Reverse transcription strand invasion-based amplification (RT-SIBA) was used to detect SARS-CoV-2 from wastewater qualitatively. RESULTS Our results indicated that the most sensitive method to detect SARS-CoV-2 in wastewater was RT-ddPCR. It had the highest positivity rate (26/30), and its limit of detection was the lowest (0.06 gene copies/µL). However, we obtained the best correlation between COVID-19 incidence and SARS-CoV-2 gene copy number in wastewater using TaqMan RT-qPCR (correlation coefficient [CC]=0.697, P<.001). We found a significant difference in sensitivity between the TaqMan RT-qPCR kit and the QuantiTect RT-qPCR kit, the first having a significantly lower limit of detection and a higher positivity rate than the latter. Furthermore, the N1 target gene assay was the most sensitive for both RT-qPCR kits, while no significant difference was found between the gene targets using RT-ddPCR. In addition, the use of different RNA extraction kits affected the result when the TaqMan RT-qPCR kit was used. RT-SIBA was able to detect SARS-CoV-2 RNA in wastewater. CONCLUSIONS As our study, as well as most of the previous studies, has shown RT-ddPCR to be more sensitive than RT-qPCR, its use in the wastewater surveillance of SARS-CoV-2 should be considered, especially if the amount of SARS-CoV-2 circulating in the population was low. All the analysis steps must be optimized for wastewater surveillance as our study showed that all the analysis steps including the compatibility of the RNA extraction, the RT-PCR kit, and the target gene assay influence the results. In addition, our study showed that RT-SIBA could be used to detect SARS-CoV-2 in wastewater if a qualitative result is sufficient.
Collapse
Affiliation(s)
- Annika Länsivaara
- Faculty of Medicine and Health Technology, Tampere University, Tampere, Finland
| | - Kirsi-Maarit Lehto
- Faculty of Medicine and Health Technology, Tampere University, Tampere, Finland
| | - Rafiqul Hyder
- Faculty of Medicine and Health Technology, Tampere University, Tampere, Finland
| | | | - Anssi Lipponen
- Expert Microbiology Unit, Finnish Institute for Health and Welfare, Kuopio, Finland
| | - Annamari Heikinheimo
- Department of Food Hygiene and Environmental Health, Faculty of Veterinary Medicine, University of Helsinki, Helsinki, Finland
- Finnish Food Authority - Ruokavirasto, Seinäjoki, Finland
| | - Tarja Pitkänen
- Expert Microbiology Unit, Finnish Institute for Health and Welfare, Kuopio, Finland
| | - Sami Oikarinen
- Faculty of Medicine and Health Technology, Tampere University, Tampere, Finland
| |
Collapse
|
4
|
Martínez de Alba ÁE, Morán-Diez ME, García-Prieto JC, García-Bernalt Diego J, Fernández-Soto P, Serrano León E, Monsalvo V, Casao M, Rubio MB, Hermosa R, Muro A, García-Roig M, Monte E. SARS-CoV-2 RNA Detection in Wastewater and Its Effective Correlation with Clinical Data during the Outbreak of COVID-19 in Salamanca. Int J Mol Sci 2024; 25:8071. [PMID: 39125640 PMCID: PMC11311535 DOI: 10.3390/ijms25158071] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/17/2024] [Revised: 07/16/2024] [Accepted: 07/20/2024] [Indexed: 08/12/2024] Open
Abstract
Wastewater treatment plants (WWTPs) are the final stage of the anthropogenic water cycle where a wide range of chemical and biological markers of human activity can be found. In COVID-19 disease contexts, wastewater surveillance has been used to infer community trends based on viral abundance and SARS-CoV-2 RNA variant composition, which has served to anticipate and establish appropriate protocols to prevent potential viral outbreaks. Numerous studies worldwide have provided reliable and robust tools to detect and quantify SARS-CoV-2 RNA in wastewater, although due to the high dilution and degradation rate of the viral RNA in such samples, the detection limit of the pathogen has been a bottleneck for the proposed protocols so far. The current work provides a comprehensive and systematic study of the different parameters that may affect the detection of SARS-CoV-2 RNA in wastewater and hinder its quantification. The results obtained using synthetic viral RNA as a template allow us to consider that 10 genome copies per µL is the minimum RNA concentration that provides reliable and consistent values for the quantification of SARS-CoV-2 RNA. RT-qPCR analysis of wastewater samples collected at the WWTP in Salamanca (western Spain) and at six pumping stations in the city showed that below this threshold, positive results must be confirmed by sequencing to identify the specific viral sequence. This allowed us to find correlations between the SARS-CoV-2 RNA levels found in wastewater and the COVID-19 clinical data reported by health authorities. The close match between environmental and clinical data from the Salamanca case study has been confirmed by similar experimental approaches in four other cities in the same region. The present methodological approach reinforces the usefulness of wastewater-based epidemiology (WBE) studies in the face of future pandemic outbreaks.
Collapse
Affiliation(s)
- Ángel Emilio Martínez de Alba
- Department of Microbiology and Genetics, Institute for Agribiotechnology Research (CIALE), University of Salamanca, 37185 Salamanca, Spain; (M.E.M.-D.); (M.B.R.); (R.H.); (E.M.)
| | - María Eugenia Morán-Diez
- Department of Microbiology and Genetics, Institute for Agribiotechnology Research (CIALE), University of Salamanca, 37185 Salamanca, Spain; (M.E.M.-D.); (M.B.R.); (R.H.); (E.M.)
| | - Juan Carlos García-Prieto
- Centre for Research and Technological Development of Water (CIDTA), University of Salamanca, 37080 Salamanca, Spain; (J.C.G.-P.); (M.G.-R.)
| | - Juan García-Bernalt Diego
- Infectious and Tropical Diseases Research Group (e-INTRO), Biomedical Research Institute of Salamanca-Research Centre for Tropical Diseases at the University of Salamanca (IBSAL-CIETUS), Faculty of Pharmacy, University of Salamanca, 37007 Salamanca, Spain; (J.G.-B.D.); (P.F.-S.); (A.M.)
| | - Pedro Fernández-Soto
- Infectious and Tropical Diseases Research Group (e-INTRO), Biomedical Research Institute of Salamanca-Research Centre for Tropical Diseases at the University of Salamanca (IBSAL-CIETUS), Faculty of Pharmacy, University of Salamanca, 37007 Salamanca, Spain; (J.G.-B.D.); (P.F.-S.); (A.M.)
| | | | | | - Marta Casao
- FCC Aqualia, 28050 Madrid, Spain; (E.S.L.); (V.M.); (M.C.)
| | - María Belén Rubio
- Department of Microbiology and Genetics, Institute for Agribiotechnology Research (CIALE), University of Salamanca, 37185 Salamanca, Spain; (M.E.M.-D.); (M.B.R.); (R.H.); (E.M.)
| | - Rosa Hermosa
- Department of Microbiology and Genetics, Institute for Agribiotechnology Research (CIALE), University of Salamanca, 37185 Salamanca, Spain; (M.E.M.-D.); (M.B.R.); (R.H.); (E.M.)
| | - Antonio Muro
- Infectious and Tropical Diseases Research Group (e-INTRO), Biomedical Research Institute of Salamanca-Research Centre for Tropical Diseases at the University of Salamanca (IBSAL-CIETUS), Faculty of Pharmacy, University of Salamanca, 37007 Salamanca, Spain; (J.G.-B.D.); (P.F.-S.); (A.M.)
| | - Manuel García-Roig
- Centre for Research and Technological Development of Water (CIDTA), University of Salamanca, 37080 Salamanca, Spain; (J.C.G.-P.); (M.G.-R.)
| | - Enrique Monte
- Department of Microbiology and Genetics, Institute for Agribiotechnology Research (CIALE), University of Salamanca, 37185 Salamanca, Spain; (M.E.M.-D.); (M.B.R.); (R.H.); (E.M.)
| |
Collapse
|
5
|
Paracchini V, Petrillo M, Arcot Rajashekar A, Robuch P, Vincent U, Corbisier P, Tavazzi S, Raffael B, Suffredini E, La Rosa G, Gawlik BM, Marchini A. EU surveys insights: analytical tools, future directions, and the essential requirement for reference materials in wastewater monitoring of SARS-CoV-2, antimicrobial resistance and beyond. Hum Genomics 2024; 18:72. [PMID: 38937848 PMCID: PMC11210120 DOI: 10.1186/s40246-024-00641-5] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/13/2024] [Accepted: 06/17/2024] [Indexed: 06/29/2024] Open
Abstract
BACKGROUND Wastewater surveillance (WWS) acts as a vigilant sentinel system for communities, analysing sewage to protect public health by detecting outbreaks and monitoring trends in pathogens and contaminants. To achieve a thorough comprehension of present and upcoming practices and to identify challenges and opportunities for standardisation and improvement in WWS methodologies, two EU surveys were conducted targeting over 750 WWS laboratories across Europe and other regions. The first survey explored a diverse range of activities currently undertaken or planned by laboratories. The second survey specifically targeted methods and quality controls utilised for SARS-CoV-2 surveillance. RESULTS The findings of the two surveys provide a comprehensive insight into the procedures and methodologies applied in WWS. In Europe, WWS primarily focuses on SARS-CoV-2 with 99% of the survey participants dedicated to this virus. However, the responses highlighted a lack of standardisation in the methodologies employed for monitoring SARS-CoV-2. The surveillance of other pathogens, including antimicrobial resistance, is currently fragmented and conducted by only a limited number of laboratories. Notably, these activities are anticipated to expand in the future. Survey replies emphasise the collective recognition of the need to enhance the accuracy of results in WWS practices, reflecting a shared commitment to advancing precision and effectiveness in WWS methodologies. CONCLUSIONS These surveys identified a lack of standardised common procedures in WWS practices and the need for quality standards and reference materials to enhance the accuracy and reliability of WWS methods in the future. In addition, it is important to broaden surveillance efforts beyond SARS-CoV-2 to include other emerging pathogens and antimicrobial resistance to ensure a comprehensive approach to protecting public health.
Collapse
Affiliation(s)
| | | | | | - Piotr Robuch
- European Commission, Joint Research Centre (JRC), Geel, Belgium
| | - Ursula Vincent
- European Commission, Joint Research Centre (JRC), Geel, Belgium
| | | | - Simona Tavazzi
- European Commission, Joint Research Centre (JRC), Ispra, Italy
| | - Barbara Raffael
- European Commission, Joint Research Centre (JRC), Ispra, Italy
| | - Elisabetta Suffredini
- Department of Food Safety, Nutrition and Veterinary Public Health, Istituto Superiore di Sanità (ISS), Rome, Italy
| | - Giuseppina La Rosa
- National Center for Water Safety (CeNSia), Istituto Superiore di Sanità (ISS), Rome, Italy
| | | | - Antonio Marchini
- European Commission, Joint Research Centre (JRC), Geel, Belgium.
| |
Collapse
|
6
|
Lehto KM, Länsivaara A, Hyder R, Luomala O, Lipponen A, Hokajärvi AM, Heikinheimo A, Pitkänen T, Oikarinen S. Wastewater-based surveillance is an efficient monitoring tool for tracking influenza A in the community. WATER RESEARCH 2024; 257:121650. [PMID: 38692254 DOI: 10.1016/j.watres.2024.121650] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 08/28/2023] [Revised: 04/18/2024] [Accepted: 04/19/2024] [Indexed: 05/03/2024]
Abstract
Around the world, influenza A virus has caused severe pandemics, and the risk of future pandemics remains high. Currently, influenza A virus surveillance is based on the clinical diagnosis and reporting of disease cases. In this study, we apply wastewater-based surveillance to monitor the amount of the influenza A virus RNA at the population level. We report the influenza A virus RNA levels in 10 wastewater treatment plant catchment areas covering 40 % of the Finnish population. Altogether, 251 monthly composite influent wastewater samples (collected between February 2021 and February 2023) were analysed from supernatant fraction using influenza A virus specific RT-qPCR method. During the study period, an influenza A virus epidemic occurred in three waves in Finland. This study shows that the influenza A virus RNA can be detected from the supernatant fraction of 24 h composite influent wastewater samples. The influenza A virus RNA gene copy number in wastewater correlated with the number of confirmed disease cases in the Finnish National Infectious Diseases Register. The median Kendall's τ correlation strength was 0.636 (min= 0.486 and max=0.804) and it was statistically significant in all 10 WTTPs. Wastewater-based surveillance of the influenza A virus RNA is an independent from individual testing method and cost-efficiently reflects the circulation of the virus in the entire population. Thus, wastewater monitoring complements the available, but often too sparse, information from individual testing and improves health care and public health preparedness for influenza A virus pandemics.
Collapse
Affiliation(s)
- Kirsi-Maarit Lehto
- Tampere University, Faculty of Medicine and Health Technology, Arvo Ylpön katu 34, Tampere 33520, Finland
| | - Annika Länsivaara
- Tampere University, Faculty of Medicine and Health Technology, Arvo Ylpön katu 34, Tampere 33520, Finland
| | - Rafiqul Hyder
- Tampere University, Faculty of Medicine and Health Technology, Arvo Ylpön katu 34, Tampere 33520, Finland
| | - Oskari Luomala
- Finnish Institute for Health and Welfare, THL, Department of Health Security, Neulaniementie 4, Kuopio 70210, Finland
| | - Anssi Lipponen
- Finnish Institute for Health and Welfare, THL, Department of Health Security, Neulaniementie 4, Kuopio 70210, Finland
| | - Anna-Maria Hokajärvi
- Finnish Institute for Health and Welfare, THL, Department of Health Security, Neulaniementie 4, Kuopio 70210, Finland
| | - Annamari Heikinheimo
- Department of Food Hygiene and Environmental Health, Faculty of Veterinary Medicine, University of Helsinki, Agnes Sjöbergin katu 2, FI00014, Finland; Finnish Food Authority, Ruokavirasto, Alvar Aallon katu 5, Seinäjoki 60100, Finland
| | - Tarja Pitkänen
- Finnish Institute for Health and Welfare, THL, Department of Health Security, Neulaniementie 4, Kuopio 70210, Finland; Department of Food Hygiene and Environmental Health, Faculty of Veterinary Medicine, University of Helsinki, Agnes Sjöbergin katu 2, FI00014, Finland
| | - Sami Oikarinen
- Tampere University, Faculty of Medicine and Health Technology, Arvo Ylpön katu 34, Tampere 33520, Finland.
| |
Collapse
|
7
|
Anastopoulou Z, Kotsiri Z, Chorti-Tripsa E, Fokas R, Vantarakis A. Urban Wastewater-Based Surveillance of SARS-CoV-2 Virus: A Two-Year Study Conducted in City of Patras, Greece. FOOD AND ENVIRONMENTAL VIROLOGY 2024:10.1007/s12560-024-09601-7. [PMID: 38829460 DOI: 10.1007/s12560-024-09601-7] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 01/14/2024] [Accepted: 04/30/2024] [Indexed: 06/05/2024]
Abstract
Wastewater-based epidemiology, during the COVID-19 pandemic years, has been applied as a complementary approach, worldwide, for tracking SARS-CoV-2 virus into the community and used as an early warning of the prevalence of COVID-19 infection. The present study presents the results of the 2-year surveillance project, in the city of Patras, Greece. The purpose of the study was to monitor SARS-CoV-2 and implement WBE as an early warning method of monitoring Public Health impact. The presence of SARS-CoV-2 was determined and quantified in 310 samples using RT-qPCR assays. For the years 2022 and 2023, 93.5% and 78.7% of samples were found positive, respectively. Comparison of detection methods have been conducted to select the method with the highest recovery of the viral load. A seasonal variation of the virus was recorded, showing a recession in summer months confirming the country's epidemiological data as indicated by positive correlation of wastewater viral load with registered cases of COVID-19 infections during these years (p < 0.05) and moreover sealed with a significant negative correlation observed with Daily Average (p < 0.01) and Daily Maximum Temperature (p < 0.01). More research was carried out to elucidate a possible association of physicochemical characteristics of wastewater with viral load showing positive correlation with Chlorides (p < 0.01) advocating possible increased use of chlorine-based disinfectants and Electrical Conductivity (p < 0.01) indicates that wastewater during periods of increased infections is more heavily loaded with ions from chemical and biological pollutants. No correlation found with rainfall and physicochemical indicators, such as COD, BOD5, Total Phosphorus, Total Nitrogen, and Total Suspended Solids. According to the findings, WBE represents a useful tool in the management of epidemics based on an environmental approach and it can also shed light on the interacting parameters that capture Public Health since any infections that may lead to epidemics lead to a parallel change in the use of pharmaceuticals, antimicrobials, disinfectants, and microbial load in urban wastewater.
Collapse
Affiliation(s)
- Zoi Anastopoulou
- Department of Medicine, Environmental Microbiology Unit, Department of Public Health, University of Patras, Patras, Greece.
| | - Zoi Kotsiri
- Department of Medicine, Environmental Microbiology Unit, Department of Public Health, University of Patras, Patras, Greece
| | - Eleftheria Chorti-Tripsa
- Department of Medicine, Laboratory of Hygiene and Environmental Protection, University of Thrace, Alexandroupoli, Greece
| | - Rafail Fokas
- Department of Medicine, Environmental Microbiology Unit, Department of Public Health, University of Patras, Patras, Greece
| | - Apostolos Vantarakis
- Department of Medicine, Environmental Microbiology Unit, Department of Public Health, University of Patras, Patras, Greece
| |
Collapse
|
8
|
Girón-Guzmán I, Cuevas-Ferrando E, Barranquero R, Díaz-Reolid A, Puchades-Colera P, Falcó I, Pérez-Cataluña A, Sánchez G. Urban wastewater-based epidemiology for multi-viral pathogen surveillance in the Valencian region, Spain. WATER RESEARCH 2024; 255:121463. [PMID: 38537489 DOI: 10.1016/j.watres.2024.121463] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 09/19/2023] [Revised: 02/28/2024] [Accepted: 03/12/2024] [Indexed: 04/24/2024]
Abstract
Wastewater-based epidemiology (WBE) has lately arised as a promising tool for monitoring and tracking viral pathogens in communities. In this study, we analysed WBE's role as a multi-pathogen surveillance strategy to detect the presence of several viral illness causative agents. Thus, an epidemiological study was conducted from October 2021 to February 2023 to estimate the weekly levels of Severe Acute Respiratory Syndrome Coronavirus 2 (SARS-CoV-2), Respiratory Syncytial virus (RSV), and Influenza A virus (IAV) in influent wastewater samples (n = 69). In parallel, a one-year study (October 2021 to October 2022) was performed to assess the presence of pathogenic human enteric viruses. Besides, monitoring of proposed viral fecal contamination indicators crAssphage and Pepper mild mottle virus (PMMoV) was also assessed, along with plaque counting of somatic coliphages. Genetic material of rotavirus (RV), human astrovirus (HAStV), and norovirus genogroup I (GI) and GII was found in almost all samples, while hepatitis A and E viruses (HAV and HEV) only tested positive in 3.77 % and 22.64 % of the samples, respectively. No seasonal patterns were overall found for enteric viruses, although RVs had a peak prevalence in the winter months. All samples tested positive for SARS-CoV-2 RNA, with a mean concentration of 5.43 log genome copies per liter (log GC/L). The tracking of the circulating SARS-CoV-2 variants of concern (VOCs) was performed by both duplex RT-qPCR and next generation sequencing (NGS). Both techniques reliably showed how the dominant VOC transitioned from Delta to Omicron during two weeks in Spain in December 2021. RSV and IAV viruses peaked in winter months with mean concentrations 6.40 and 4.10 log GC/L, respectively. Moreover, the three selected respiratory viruses strongly correlated with reported clinical data when normalised by wastewater physico-chemical parameters and presented weaker correlations when normalising sewage concentration levels with crAssphage or somatic coliphages titers. Finally, predictive models were generated for each respiratory virus, confirming high reliability on WBE data as an early-warning system and communities illness monitoring system. Overall, this study presents WBE as an optimal tool for multi-pathogen tracking reflecting viral circulation and diseases trends within a selected area, its value as a multi-pathogen early-warning tool stands out due to its public health interest.
Collapse
Affiliation(s)
- Inés Girón-Guzmán
- Institute of Agrochemistry and Food Technology, IATA-CSIC, Av. Agustín Escardino 7, Paterna, Valencia 46980, Spain
| | - Enric Cuevas-Ferrando
- Institute of Agrochemistry and Food Technology, IATA-CSIC, Av. Agustín Escardino 7, Paterna, Valencia 46980, Spain.
| | - Regino Barranquero
- Institute of Agrochemistry and Food Technology, IATA-CSIC, Av. Agustín Escardino 7, Paterna, Valencia 46980, Spain
| | - Azahara Díaz-Reolid
- Institute of Agrochemistry and Food Technology, IATA-CSIC, Av. Agustín Escardino 7, Paterna, Valencia 46980, Spain
| | - Pablo Puchades-Colera
- Institute of Agrochemistry and Food Technology, IATA-CSIC, Av. Agustín Escardino 7, Paterna, Valencia 46980, Spain
| | - Irene Falcó
- Institute of Agrochemistry and Food Technology, IATA-CSIC, Av. Agustín Escardino 7, Paterna, Valencia 46980, Spain; Department of Microbiology and Ecology, University of Valencia, Valencia, Spain
| | - Alba Pérez-Cataluña
- Institute of Agrochemistry and Food Technology, IATA-CSIC, Av. Agustín Escardino 7, Paterna, Valencia 46980, Spain
| | - Gloria Sánchez
- Institute of Agrochemistry and Food Technology, IATA-CSIC, Av. Agustín Escardino 7, Paterna, Valencia 46980, Spain.
| |
Collapse
|
9
|
Bustin SA. Improving the quality of quantitative polymerase chain reaction experiments: 15 years of MIQE. Mol Aspects Med 2024; 96:101249. [PMID: 38290180 DOI: 10.1016/j.mam.2024.101249] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/24/2023] [Revised: 01/02/2024] [Accepted: 01/15/2024] [Indexed: 02/01/2024]
Abstract
The quantitative polymerase chain reaction (qPCR) is fundamental to molecular biology. It is not just a laboratory technique, qPCR is a bridge between research and clinical practice. Its theoretical foundations guide the design of experiments, while its practical implications extend to diagnostics, treatment, and research advancements in the life sciences, human and veterinary medicine, agriculture, and forensics. However, the accuracy, reliability and reproducibility of qPCR data face challenges arising from various factors associated with experimental design, execution, data analysis and inadequate reporting details. Addressing these concerns, the Minimum Information for the Publication of Quantitative Real-Time PCR Experiments (MIQE) guidelines have emerged as a cohesive framework offering a standardised set of recommendations that describe the essential information required for assessing qPCR experiments. By emphasising the importance of methodological rigour, the MIQE guidelines have made a major contribution to improving the trustworthiness, consistency, and transparency of many published qPCR results. However, major challenges related to awareness, resources, and publication pressures continue to affect their consistent application.
Collapse
Affiliation(s)
- Stephen A Bustin
- Medical Technology Research Centre, Anglia Ruskin University, Chelmsford, Essex, CM1 1SQ, UK.
| |
Collapse
|
10
|
Ryon MG, Langan LM, Brennan C, O'Brien ME, Bain FL, Miller AE, Snow CC, Salinas V, Norman RS, Bojes HK, Brooks BW. Influences of 23 different equations used to calculate gene copies of SARS-CoV-2 during wastewater-based epidemiology. THE SCIENCE OF THE TOTAL ENVIRONMENT 2024; 917:170345. [PMID: 38272099 DOI: 10.1016/j.scitotenv.2024.170345] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 10/01/2023] [Revised: 12/01/2023] [Accepted: 01/19/2024] [Indexed: 01/27/2024]
Abstract
Following the emergence of severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) in late 2019, the use of wastewater-based surveillance (WBS) has increased dramatically along with associated infrastructure globally. However, due to the global nature of its application, and various workflow adaptations (e.g., sample collection, water concentration, RNA extraction kits), numerous methods for back-calculation of gene copies per volume (gc/L) of sewage have also emerged. Many studies have considered the comparability of processing methods (e.g., water concentration, RNA extraction); however, for equations used to calculate gene copies in a wastewater sample and subsequent influences on monitoring viral trends in a community and its association with epidemiological data, less is known. Due to limited information on how many formulas exist for the calculation of SARS-CoV-2 gene copies in wastewater, we initially attempted to quantify how many equations existed in the referred literature. We identified 23 unique equations, which were subsequently applied to an existing wastewater dataset. We observed a range of gene copies based on use of different equations, along with variability of AUC curve values, and results from correlation and regression analyses. Though a number of individual laboratories appear to have independently converged on a similar formula for back-calculation of viral load in wastewater, and share similar relationships with epidemiological data, differential influences of various equations were observed for variation in PCR volumes, RNA extraction volumes, or PCR assay parameters. Such observations highlight challenges when performing comparisons among WBS studies when numerous methodologies and back-calculation methods exist. To facilitate reproducibility among studies, the different gc/L equations were packaged as an R Shiny app, which provides end users the ability to investigate variability within their datasets and support comparisons among studies.
Collapse
Affiliation(s)
- Mia G Ryon
- Department of Environmental Science, Baylor University, One Bear Place #97266, Waco, TX 76798, USA; Center for Reservoir and Aquatic Systems Research, Baylor University, One Bear Place #97178, Waco, TX 76798, USA
| | - Laura M Langan
- Department of Environmental Science, Baylor University, One Bear Place #97266, Waco, TX 76798, USA; Center for Reservoir and Aquatic Systems Research, Baylor University, One Bear Place #97178, Waco, TX 76798, USA.
| | - Christopher Brennan
- Department of Entomology, Texas A&M University, TAMU 2475, College Station, TX 77843-2475, USA
| | - Megan E O'Brien
- Department of Environmental Science, Baylor University, One Bear Place #97266, Waco, TX 76798, USA; Center for Reservoir and Aquatic Systems Research, Baylor University, One Bear Place #97178, Waco, TX 76798, USA
| | - Fallon L Bain
- Department of Environmental Science, Baylor University, One Bear Place #97266, Waco, TX 76798, USA; Center for Reservoir and Aquatic Systems Research, Baylor University, One Bear Place #97178, Waco, TX 76798, USA
| | - Aubree E Miller
- Department of Environmental Science, Baylor University, One Bear Place #97266, Waco, TX 76798, USA; Center for Reservoir and Aquatic Systems Research, Baylor University, One Bear Place #97178, Waco, TX 76798, USA
| | - Christine C Snow
- Department of Environmental Science, Baylor University, One Bear Place #97266, Waco, TX 76798, USA; Center for Reservoir and Aquatic Systems Research, Baylor University, One Bear Place #97178, Waco, TX 76798, USA
| | - Victoria Salinas
- Environmental Epidemiology and Disease Registries, Texas Department of State Health Services, Austin, TX 78756, USA
| | - R Sean Norman
- Department of Environmental Health Sciences, Arnold School of Public Health, University of South Carolina, 921 Assembly St., Columbia, SC 28208, USA
| | - Heidi K Bojes
- Environmental Epidemiology and Disease Registries, Texas Department of State Health Services, Austin, TX 78756, USA
| | - Bryan W Brooks
- Department of Environmental Science, Baylor University, One Bear Place #97266, Waco, TX 76798, USA; Center for Reservoir and Aquatic Systems Research, Baylor University, One Bear Place #97178, Waco, TX 76798, USA; Department of Public Health, Baylor University, One Bear Place #97343, Waco, TX 76798, USA.
| |
Collapse
|
11
|
Parkins MD, Lee BE, Acosta N, Bautista M, Hubert CRJ, Hrudey SE, Frankowski K, Pang XL. Wastewater-based surveillance as a tool for public health action: SARS-CoV-2 and beyond. Clin Microbiol Rev 2024; 37:e0010322. [PMID: 38095438 PMCID: PMC10938902 DOI: 10.1128/cmr.00103-22] [Citation(s) in RCA: 1] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 03/16/2024] Open
Abstract
Wastewater-based surveillance (WBS) has undergone dramatic advancement in the context of the coronavirus disease 2019 (COVID-19) pandemic. The power and potential of this platform technology were rapidly realized when it became evident that not only did WBS-measured SARS-CoV-2 RNA correlate strongly with COVID-19 clinical disease within monitored populations but also, in fact, it functioned as a leading indicator. Teams from across the globe rapidly innovated novel approaches by which wastewater could be collected from diverse sewersheds ranging from wastewater treatment plants (enabling community-level surveillance) to more granular locations including individual neighborhoods and high-risk buildings such as long-term care facilities (LTCF). Efficient processes enabled SARS-CoV-2 RNA extraction and concentration from the highly dilute wastewater matrix. Molecular and genomic tools to identify, quantify, and characterize SARS-CoV-2 and its various variants were adapted from clinical programs and applied to these mixed environmental systems. Novel data-sharing tools allowed this information to be mobilized and made immediately available to public health and government decision-makers and even the public, enabling evidence-informed decision-making based on local disease dynamics. WBS has since been recognized as a tool of transformative potential, providing near-real-time cost-effective, objective, comprehensive, and inclusive data on the changing prevalence of measured analytes across space and time in populations. However, as a consequence of rapid innovation from hundreds of teams simultaneously, tremendous heterogeneity currently exists in the SARS-CoV-2 WBS literature. This manuscript provides a state-of-the-art review of WBS as established with SARS-CoV-2 and details the current work underway expanding its scope to other infectious disease targets.
Collapse
Affiliation(s)
- Michael D. Parkins
- Department of Microbiology, Immunology and Infectious Diseases, University of Calgary, Calgary, Alberta, Canada
- Department of Medicine, Cumming School of Medicine, University of Calgary, Calgary, Alberta, Canada
- O’Brien Institute of Public Health, Cumming School of Medicine, University of Calgary, Calgary, Alberta, Canada
| | - Bonita E. Lee
- Department of Pediatrics, Faculty of Medicine and Dentistry, University of Alberta, Edmonton, Alberta, Canada
| | - Nicole Acosta
- Department of Medicine, Cumming School of Medicine, University of Calgary, Calgary, Alberta, Canada
| | - Maria Bautista
- Department of Biological Sciences, Faculty of Science, University of Calgary, Calgary, Alberta, Canada
| | - Casey R. J. Hubert
- Department of Biological Sciences, Faculty of Science, University of Calgary, Calgary, Alberta, Canada
| | - Steve E. Hrudey
- Department of Laboratory Medicine and Pathology, University of Alberta, Edmonton, Alberta, Canada
| | - Kevin Frankowski
- Advancing Canadian Water Assets, University of Calgary, Calgary, Alberta, Canada
| | - Xiao-Li Pang
- Department of Laboratory Medicine and Pathology, University of Alberta, Edmonton, Alberta, Canada
- Provincial Health Laboratory, Alberta Health Services, Calgary, Alberta, Canada
| |
Collapse
|
12
|
Thakali O, Mercier É, Eid W, Wellman M, Brasset-Gorny J, Overton AK, Knapp JJ, Manuel D, Charles TC, Goodridge L, Arts EJ, Poon AFY, Brown RS, Graber TE, Delatolla R, DeGroot CT. Real-time evaluation of signal accuracy in wastewater surveillance of pathogens with high rates of mutation. Sci Rep 2024; 14:3728. [PMID: 38355869 PMCID: PMC10866965 DOI: 10.1038/s41598-024-54319-y] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/02/2023] [Accepted: 02/11/2024] [Indexed: 02/16/2024] Open
Abstract
Wastewater surveillance of coronavirus disease 2019 (COVID-19) commonly applies reverse transcription-quantitative polymerase chain reaction (RT-qPCR) to quantify severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) RNA concentrations in wastewater over time. In most applications worldwide, maximal sensitivity and specificity of RT-qPCR has been achieved, in part, by monitoring two or more genomic loci of SARS-CoV-2. In Ontario, Canada, the provincial Wastewater Surveillance Initiative reports the average copies of the CDC N1 and N2 loci normalized to the fecal biomarker pepper mild mottle virus. In November 2021, the emergence of the Omicron variant of concern, harboring a C28311T mutation within the CDC N1 probe region, challenged the accuracy of the consensus between the RT-qPCR measurements of the N1 and N2 loci of SARS-CoV-2. In this study, we developed and applied a novel real-time dual loci quality assurance and control framework based on the relative difference between the loci measurements to the City of Ottawa dataset to identify a loss of sensitivity of the N1 assay in the period from July 10, 2022 to January 31, 2023. Further analysis via sequencing and allele-specific RT-qPCR revealed a high proportion of mutations C28312T and A28330G during the study period, both in the City of Ottawa and across the province. It is hypothesized that nucleotide mutations in the probe region, especially A28330G, led to inefficient annealing, resulting in reduction in sensitivity and accuracy of the N1 assay. This study highlights the importance of implementing quality assurance and control criteria to continually evaluate, in near real-time, the accuracy of the signal produced in wastewater surveillance applications that rely on detection of pathogens whose genomes undergo high rates of mutation.
Collapse
Affiliation(s)
- Ocean Thakali
- Department of Civil Engineering, University of Ottawa, Ottawa, ON, K1N 6N5, Canada
| | - Élisabeth Mercier
- Department of Civil Engineering, University of Ottawa, Ottawa, ON, K1N 6N5, Canada
| | - Walaa Eid
- Children's Hospital of Eastern Ontario Research Institute, Ottawa, ON, K1H 8L1, Canada
| | - Martin Wellman
- The Ottawa Hospital Research Institute, 1053 Carling Ave, Ottawa, ON, K1Y 4E9, Canada
| | - Julia Brasset-Gorny
- Children's Hospital of Eastern Ontario Research Institute, Ottawa, ON, K1H 8L1, Canada
| | - Alyssa K Overton
- Department of Biology, University of Waterloo, 200 University Avenue West, Waterloo, ON, N2L 3G1, Canada
| | - Jennifer J Knapp
- Department of Biology, University of Waterloo, 200 University Avenue West, Waterloo, ON, N2L 3G1, Canada
| | - Douglas Manuel
- Children's Hospital of Eastern Ontario Research Institute, Ottawa, ON, K1H 8L1, Canada
- Department of Family Medicine, University of Ottawa, 75 Laurier Ave. E, Ottawa, ON, K1N 6N5, Canada
- School of Epidemiology and Public Health, University of Ottawa, 75 Laurier Ave. E, Ottawa, ON, K1N 6N5, Canada
| | - Trevor C Charles
- Department of Biology, University of Waterloo, 200 University Avenue West, Waterloo, ON, N2L 3G1, Canada
| | - Lawrence Goodridge
- Department of Food Science, Canadian Research Institute for Food Safety, University of Guelph, Guelph, ON, N1G 2W1, Canada
| | - Eric J Arts
- Department of Microbiology and Immunology, Western University, London, ON, N6A 3K7, Canada
| | - Art F Y Poon
- Department of Microbiology and Immunology, Western University, London, ON, N6A 3K7, Canada
| | - R Stephen Brown
- School of Environmental Studies and Department of Chemistry, Queen's University, Kingston, ON, Canada
| | - Tyson E Graber
- Children's Hospital of Eastern Ontario Research Institute, Ottawa, ON, K1H 8L1, Canada
| | - Robert Delatolla
- Department of Civil Engineering, University of Ottawa, Ottawa, ON, K1N 6N5, Canada
| | - Christopher T DeGroot
- Department of Mechanical and Materials Engineering, Western University, London, ON, N6A 5B9, Canada.
| |
Collapse
|
13
|
Armenta-Castro A, Núñez-Soto MT, Rodriguez-Aguillón KO, Aguayo-Acosta A, Oyervides-Muñoz MA, Snyder SA, Barceló D, Saththasivam J, Lawler J, Sosa-Hernández JE, Parra-Saldívar R. Urine biomarkers for Alzheimer's disease: A new opportunity for wastewater-based epidemiology? ENVIRONMENT INTERNATIONAL 2024; 184:108462. [PMID: 38335627 DOI: 10.1016/j.envint.2024.108462] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 10/08/2023] [Revised: 01/16/2024] [Accepted: 01/26/2024] [Indexed: 02/12/2024]
Abstract
While Alzheimer's disease (AD) diagnosis, management, and care have become priorities for healthcare providers and researcher's worldwide due to rapid population aging, epidemiologic surveillance efforts are currently limited by costly, invasive diagnostic procedures, particularly in low to middle income countries (LMIC). In recent years, wastewater-based epidemiology (WBE) has emerged as a promising tool for public health assessment through detection and quantification of specific biomarkers in wastewater, but applications for non-infectious diseases such as AD remain limited. This early review seeks to summarize AD-related biomarkers and urine and other peripheral biofluids and discuss their potential integration to WBE platforms to guide the first prospective efforts in the field. Promising results have been reported in clinical settings, indicating the potential of amyloid β, tau, neural thread protein, long non-coding RNAs, oxidative stress markers and other dysregulated metabolites for AD diagnosis, but questions regarding their concentration and stability in wastewater and the correlation between clinical levels and sewage circulation must be addressed in future studies before comprehensive WBE systems can be developed.
Collapse
Affiliation(s)
| | - Mónica T Núñez-Soto
- Tecnologico de Monterrey, School of Engineering and Sciences, Monterrey 64849, Mexico
| | - Kassandra O Rodriguez-Aguillón
- Tecnologico de Monterrey, School of Engineering and Sciences, Monterrey 64849, Mexico; Tecnologico de Monterrey, Institute of Advanced Materials for Sustainable Manufacturing, Monterrey 64849, Mexico
| | - Alberto Aguayo-Acosta
- Tecnologico de Monterrey, School of Engineering and Sciences, Monterrey 64849, Mexico; Tecnologico de Monterrey, Institute of Advanced Materials for Sustainable Manufacturing, Monterrey 64849, Mexico
| | - Mariel Araceli Oyervides-Muñoz
- Tecnologico de Monterrey, School of Engineering and Sciences, Monterrey 64849, Mexico; Tecnologico de Monterrey, Institute of Advanced Materials for Sustainable Manufacturing, Monterrey 64849, Mexico
| | - Shane A Snyder
- Nanyang Environment & Water Research Institute (NEWRI), Nanyang Technological University, Singapore
| | - Damià Barceló
- Department of Environmental Chemistry, Institute of Environmental Assessment and Water Research, IDAEA-CSIC, Jordi Girona, 18-26, 08034 Barcelona, Spain; Sustainability Cluster, School of Engineering at the UPES, Dehradun, Uttarakhand, India
| | - Jayaprakash Saththasivam
- Water Center, Qatar Environment & Energy Research Institute, Hamad Bin Khalifa University, Qatar Foundation, Qatar
| | - Jenny Lawler
- Water Center, Qatar Environment & Energy Research Institute, Hamad Bin Khalifa University, Qatar Foundation, Qatar
| | - Juan Eduardo Sosa-Hernández
- Tecnologico de Monterrey, School of Engineering and Sciences, Monterrey 64849, Mexico; Tecnologico de Monterrey, Institute of Advanced Materials for Sustainable Manufacturing, Monterrey 64849, Mexico.
| | - Roberto Parra-Saldívar
- Tecnologico de Monterrey, School of Engineering and Sciences, Monterrey 64849, Mexico; Tecnologico de Monterrey, Institute of Advanced Materials for Sustainable Manufacturing, Monterrey 64849, Mexico
| |
Collapse
|
14
|
Lowenthal MS, Antonishek AS, Phinney KW. Quantification of mRNA in Lipid Nanoparticles Using Mass Spectrometry. Anal Chem 2024; 96:1214-1222. [PMID: 38189247 PMCID: PMC10809213 DOI: 10.1021/acs.analchem.3c04406] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/29/2023] [Revised: 12/26/2023] [Accepted: 12/26/2023] [Indexed: 01/09/2024]
Abstract
Lipid nanoparticle-encapsulated mRNA (LNP-mRNA) holds great promise as a novel modality for treating a broad range of diseases. The ability to quantify mRNA accurately in therapeutic products helps to ensure consistency and safety. Here, we consider a central aspect of accuracy, measurement traceability, which establishes trueness in quantity. In this study, LNP-mRNA is measured in situ using a novel liquid chromatography-mass spectrometry (LC-MS) approach with traceable quantification. Previous works established that oligonucleotide quantification is possible through the accounting of an oligomer's fundamental nucleobases, with traceability established through common nucleobase calibrators. This sample preparation does not require mRNA extraction, detergents, or enzymes and can be achieved through direct acid hydrolysis of an LNP-mRNA product prior to an isotope dilution strategy. This results in an accurate quantitative analysis of mRNA, independent of time or place. Acid hydrolysis LC-MS is demonstrated to be amenable to measuring mRNA as both an active substance or a formulated mRNA drug product.
Collapse
Affiliation(s)
- Mark S. Lowenthal
- Biomolecular Measurement
Division, Material Measurement Lab, National
Institute of Standards and Technology (NIST), Gaithersburg, Maryland 20899, United States
| | - Abigail S. Antonishek
- Biomolecular Measurement
Division, Material Measurement Lab, National
Institute of Standards and Technology (NIST), Gaithersburg, Maryland 20899, United States
| | - Karen W. Phinney
- Biomolecular Measurement
Division, Material Measurement Lab, National
Institute of Standards and Technology (NIST), Gaithersburg, Maryland 20899, United States
| |
Collapse
|
15
|
Ding J, Xu X, Deng Y, Zheng X, Zhang T. Comparison of RT-ddPCR and RT-qPCR platforms for SARS-CoV-2 detection: Implications for future outbreaks of infectious diseases. ENVIRONMENT INTERNATIONAL 2024; 183:108438. [PMID: 38232505 DOI: 10.1016/j.envint.2024.108438] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 10/31/2023] [Revised: 01/08/2024] [Accepted: 01/09/2024] [Indexed: 01/19/2024]
Abstract
The increased frequency of human infectious disease outbreaks caused by RNA viruses worldwide in recent years calls for enhanced public health surveillance for better future preparedness. Wastewater-based epidemiology (WBE) is emerging as a valuable epidemiological tool for providing timely population-wide surveillance for disease prevention and response complementary to the current clinical surveillance system. Here, we compared the analytical performance and practical applications between predominant molecular detection methods of RT-qPCR and RT-ddPCR on SARS-CoV-2 detection in wastewater surveillance. When pure viral RNA was tested, RT-ddPCR exhibited superior quantification accuracy at higher concentration levels and achieved more sensitive detection with reduced variation at low concentration levels. Furthermore, RT-ddPCR consistently demonstrated more robust and accurate measurement either in the background of the wastewater matrix or with the presence of mismatches in the target regions of the consensus assay. Additionally, by detecting mock variant RNA samples, we found that RT-ddPCR outperformed RT-qPCR in virus genotyping by targeting specific loci with signature mutations in allele-specific (AS) assays, especially at low levels of allele frequencies and concentrations, which increased the possibility for sensitive low-prevalence variant detection in the population. Our study provides insights for detection method selection in the WBE applications for future infectious disease outbreaks.
Collapse
Affiliation(s)
- Jiahui Ding
- Environmental Microbiome Engineering and Biotechnology Laboratory, Center for Environmental Engineering Research, Department of Civil Engineering, The University of Hong Kong, Pokfulam Road, Hong Kong Special Administrative Region
| | - Xiaoqing Xu
- Environmental Microbiome Engineering and Biotechnology Laboratory, Center for Environmental Engineering Research, Department of Civil Engineering, The University of Hong Kong, Pokfulam Road, Hong Kong Special Administrative Region
| | - Yu Deng
- Environmental Microbiome Engineering and Biotechnology Laboratory, Center for Environmental Engineering Research, Department of Civil Engineering, The University of Hong Kong, Pokfulam Road, Hong Kong Special Administrative Region
| | - Xiawan Zheng
- Environmental Microbiome Engineering and Biotechnology Laboratory, Center for Environmental Engineering Research, Department of Civil Engineering, The University of Hong Kong, Pokfulam Road, Hong Kong Special Administrative Region
| | - Tong Zhang
- Environmental Microbiome Engineering and Biotechnology Laboratory, Center for Environmental Engineering Research, Department of Civil Engineering, The University of Hong Kong, Pokfulam Road, Hong Kong Special Administrative Region.
| |
Collapse
|
16
|
de la Cruz Barron M, Kneis D, Geissler M, Dumke R, Dalpke A, Berendonk TU. Evaluating the sensitivity of droplet digital PCR for the quantification of SARS-CoV-2 in wastewater. Front Public Health 2023; 11:1271594. [PMID: 38425410 PMCID: PMC10903512 DOI: 10.3389/fpubh.2023.1271594] [Citation(s) in RCA: 2] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/02/2023] [Accepted: 11/27/2023] [Indexed: 03/02/2024] Open
Abstract
Wastewater surveillance for SARS-CoV-2 has been demonstrated to be a valuable tool in monitoring community-level virus circulation and assessing new outbreaks. It may become a useful tool in the early detection and response to future pandemics, enabling public health authorities to implement timely interventions and mitigate the spread of infectious diseases with the fecal excretion of their agents. It also offers a chance for cost-effective surveillance. Reverse transcription-quantitative polymerase chain reaction (RTqPCR) is the most commonly used method for viral RNA detection in wastewater due to its sensitivity, reliability, and widespread availability. However, recent studies have indicated that reverse transcription droplet digital PCR (RTddPCR) has the potential to offer improved sensitivity and accuracy for quantifying SARS-CoV-2 RNA in wastewater samples. In this study, we compared the performance of RTqPCR and RTddPCR approaches for SARS-CoV-2 detection and quantification on wastewater samples collected during the third epidemic wave in Saxony, Germany, characterized by low-incidence infection periods. The determined limits of detection (LOD) and quantification (LOQ) were within the same order of magnitude, and no significant differences were observed between the PCR approaches with respect to the number of positive or quantifiable samples. Our results indicate that both RTqPCR and RTddPCR are highly sensitive methods for detecting SARS-CoV-2. Consequently, the actual gain in sensitivity associated with ddPCR lags behind theoretical expectations. Hence, the choice between the two PCR methods in further environmental surveillance programs is rather a matter of available resources and throughput requirements.
Collapse
Affiliation(s)
| | - David Kneis
- Institute of Hydrobiology, Technische Universität Dresden, Dresden, Germany
| | - Michael Geissler
- Institute of Medical Microbiology and Virology, University Hospital Carl Gustav Carus, Technische Universität Dresden, Dresden, Germany
| | - Roger Dumke
- Institute of Medical Microbiology and Virology, University Hospital Carl Gustav Carus, Technische Universität Dresden, Dresden, Germany
| | - Alexander Dalpke
- Institute of Medical Microbiology and Virology, University Hospital Carl Gustav Carus, Technische Universität Dresden, Dresden, Germany
- Department of Infectious Diseases, Medical Microbiology and Hygiene, University Heidelberg, Heidelberg, Germany
| | | |
Collapse
|
17
|
Nagelkerke E, Hetebrij WA, Koelewijn JM, Kooij J, van der Drift AMR, van der Beek RFHJ, de Jonge EF, Lodder WJ. PCR standard curve quantification in an extensive wastewater surveillance program: results from the Dutch SARS-CoV-2 wastewater surveillance. Front Public Health 2023; 11:1141494. [PMID: 38026384 PMCID: PMC10652756 DOI: 10.3389/fpubh.2023.1141494] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/10/2023] [Accepted: 09/22/2023] [Indexed: 12/01/2023] Open
Abstract
Since the start of the COVID-19 pandemic in 2020, wastewater surveillance programs were established, or upscaled, in many countries around the world and have proven to be a cost-effective way of monitoring infectious disease pathogens. Many of these programs use RT-qPCR, and quantify the viral concentrations in samples based on standard curves, by including preparations of a reference material with known nucleic acid or virus concentrations in the RT-qPCR analyses. In high-throughput monitoring programs it is possible to combine data from multiple previous runs, circumventing the need for duplication and resulting in decreased costs and prolonged periods during which the reference material is obtained from the same batch. However, over time, systematic shifts in standard curves are likely to occur. This would affect the reliability and usefulness of wastewater surveillance as a whole. We aim to find an optimal combination of standard curve data to compensate for run-to-run measurement variance while ensuring enough flexibility to capture systematic longitudinal shifts. Based on more than 4000 observations obtained with the CDC N1 and N2 assays, taken as a part of the National Sewage Surveillance program at the Dutch National Institute for Public Health and the Environment, we show that seasonal and long-term shifts in RT-qPCR efficiency and sensitivity occur. We find that in our setting, using five days of standard-curve data to quantify, results in the least error prone curve or best approximation. This results in differences up to 100% in quantified viral loads when averaged out over a nationwide program of >300 treatment plants. Results show that combining standard curves from a limited set of runs can be a valid approach to quantification without obscuring the trends in the viral load of interest.
Collapse
Affiliation(s)
- Erwin Nagelkerke
- Centre for Infectious Disease Control, National Institute for Public Health and the Environment (RIVM), Bilthoven, Netherlands
| | | | | | | | | | | | | | | |
Collapse
|
18
|
Bohrerova Z, Brinkman NE, Chakravarti R, Chattopadhyay S, Faith SA, Garland J, Herrin J, Hull N, Jahne M, Kang DW, Keely SP, Lee J, Lemeshow S, Lenhart J, Lytmer E, Malgave D, Miao L, Minard-Smith A, Mou X, Nagarkar M, Quintero A, Savona FDR, Senko J, Slonczewski JL, Spurbeck RR, Sovic MG, Taylor RT, Weavers LK, Weir M. Ohio Coronavirus Wastewater Monitoring Network: Implementation of Statewide Monitoring for Protecting Public Health. JOURNAL OF PUBLIC HEALTH MANAGEMENT AND PRACTICE 2023; 29:845-853. [PMID: 37738597 PMCID: PMC10539008 DOI: 10.1097/phh.0000000000001783] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 09/24/2023]
Abstract
CONTEXT Prior to the COVID-19 pandemic, wastewater influent monitoring for tracking disease burden in sewered communities was not performed in Ohio, and this field was only on the periphery of the state academic research community. PROGRAM Because of the urgency of the pandemic and extensive state-level support for this new technology to detect levels of community infection to aid in public health response, the Ohio Water Resources Center established relationships and support of various stakeholders. This enabled Ohio to develop a statewide wastewater SARS-CoV-2 (severe acute respiratory syndrome coronavirus 2) monitoring network in 2 months starting in July 2020. IMPLEMENTATION The current Ohio Coronavirus Wastewater Monitoring Network (OCWMN) monitors more than 70 unique locations twice per week, and publicly available data are updated weekly on the public dashboard. EVALUATION This article describes the process and decisions that were made during network initiation, the network progression, and data applications, which can inform ongoing and future pandemic response and wastewater monitoring. DISCUSSION Overall, the OCWMN established wastewater monitoring infrastructure and provided a useful tool for public health professionals responding to the pandemic.
Collapse
Affiliation(s)
- Zuzana Bohrerova
- Ohio Water Resources Center (Drs Bohrerova, Lenhart, and Weavers), Civil, Environmental and Geodetic Engineering (Drs Bohrerova, Hull, Lenhart, and Weavers), Infectious Diseases Institute (Drs Faith and Lee and Ms Savona), Sustainability Institute (Dr Hull), Department of Food Science & Technology (Dr Lee), and Center for Applied Plant Sciences (Dr Sovic), The Ohio State University, Columbus, Ohio; Office of Research and Development, US Environmental Protection Agency, Washington, District of Columbia (Drs Brinkman, Garland, Jahne, Keely, and Nagarkar); Departments of Physiology and Pharmacology (Dr Chakravarti) and Medical Microbiology and Immunology (Drs Chattopadhyay and Taylor), University of Toledo College of Medicine and Life Sciences, Toledo, Ohio; LuminUltra Technologies Inc, Hialeah, Florida (Mr Herrin and Dr Quintero); Department of Civil and Environmental Engineering, University of Toledo, Toledo, Ohio (Dr Kang); Divisions of Environmental Health Sciences (Drs Lee and Weir) and Biostatistics (Drs Lemeshow and Malgave and Ms Miao), The Ohio State University College of Public Health, Columbus, Ohio; Department of Biological Sciences, Bowling Green State University, Bowling Green, Ohio (Ms Lytmer); Health Outcomes and Biotechnology Solutions, Battelle Memorial Institute, Columbus, Ohio (Ms Minard-Smith and Dr Spurbeck); Department of Biological Sciences, Kent State University, Kent, Ohio (Dr Mou); Department of Geosciences and Department of Biology, The University of Akron, Akron, Ohio (Dr Senko); and Department of Biology, Kenyon College, Gambier, Ohio (Dr Slonczewski)
| | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | |
Collapse
|
19
|
Han X, Beck K, Bürgmann H, Frey B, Stierli B, Frossard A. Synthetic oligonucleotides as quantitative PCR standards for quantifying microbial genes. Front Microbiol 2023; 14:1279041. [PMID: 37942081 PMCID: PMC10627841 DOI: 10.3389/fmicb.2023.1279041] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/17/2023] [Accepted: 10/09/2023] [Indexed: 11/10/2023] Open
Abstract
Real-time quantitative PCR (qPCR) has been widely used to quantify gene copy numbers in microbial ecology. Despite its simplicity and straightforwardness, establishing qPCR assays is often impeded by the tedious process of producing qPCR standards by cloning the target DNA into plasmids. Here, we designed double-stranded synthetic DNA fragments from consensus sequences as qPCR standards by aligning microbial gene sequences (10-20 sequences per gene). Efficiency of standards from synthetic DNA was compared with plasmid standards by qPCR assays for different phylogenetic marker and functional genes involved in carbon (C) and nitrogen (N) cycling, tested with DNA extracted from a broad range of soils. Results showed that qPCR standard curves using synthetic DNA performed equally well to those from plasmids for all the genes tested. Furthermore, gene copy numbers from DNA extracted from soils obtained by using synthetic standards or plasmid standards were comparable. Our approach therefore demonstrates that a synthetic DNA fragment as qPCR standard provides comparable sensitivity and reliability to a traditional plasmid standard, while being more time- and cost-efficient.
Collapse
Affiliation(s)
- Xingguo Han
- Forest Soils and Biogeochemistry, Swiss Federal Institute for Forest, Snow and Landscape Research (WSL), Birmensdorf, Switzerland
| | - Karin Beck
- Eawag, Swiss Federal Institute of Aquatic Science and Technology, Kastanienbaum, Switzerland
| | - Helmut Bürgmann
- Eawag, Swiss Federal Institute of Aquatic Science and Technology, Kastanienbaum, Switzerland
| | - Beat Frey
- Forest Soils and Biogeochemistry, Swiss Federal Institute for Forest, Snow and Landscape Research (WSL), Birmensdorf, Switzerland
| | - Beat Stierli
- Forest Soils and Biogeochemistry, Swiss Federal Institute for Forest, Snow and Landscape Research (WSL), Birmensdorf, Switzerland
| | - Aline Frossard
- Forest Soils and Biogeochemistry, Swiss Federal Institute for Forest, Snow and Landscape Research (WSL), Birmensdorf, Switzerland
| |
Collapse
|
20
|
Thapar I, Langan LM, Davis H, Norman RS, Bojes HK, Brooks BW. Influence of storage conditions and multiple freeze-thaw cycles on N1 SARS-CoV-2, PMMoV, and BCoV signal. THE SCIENCE OF THE TOTAL ENVIRONMENT 2023; 896:165098. [PMID: 37392884 PMCID: PMC10307669 DOI: 10.1016/j.scitotenv.2023.165098] [Citation(s) in RCA: 3] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 03/28/2023] [Revised: 06/16/2023] [Accepted: 06/21/2023] [Indexed: 07/03/2023]
Abstract
Wastewater-based epidemiology/wastewater-based surveillance (WBE/WBS) continues to serve as an effective means of monitoring various diseases, including COVID-19 and the emergence of SARS-CoV-2 variants, at the population level. As the use of WBE expands, storage conditions of wastewater samples will play a critical role in ensuring the accuracy and reproducibility of results. In this study, the impacts of water concentration buffer (WCB), storage temperature, and freeze-thaw cycles on the detection of SARS-CoV-2 and other WBE-related gene targets were examined. Freeze-thawing of concentrated samples did not significantly affect (p > 0.05) crossing/cycle threshold (Ct) value for any of the gene targets studied (SARS-CoV-2 N1, PMMoV, and BCoV). However, use of WCB during concentration resulted in a significant (p < 0.05) decrease in Ct for all targets, and storage at -80 °C (in contrast to -20 °C) appeared preferable for wastewater storage signal stability based on decreased Ct values, although this was only significantly different (p < 0.05) for the BCoV target. Interestingly, when Ct values were converted to gene copies per influent sample, no significant differences (p > 0.05) were observed in any of the targets examined. Stability of RNA targets in concentrated wastewater against freeze-thaw degradation supports archiving of concentrated samples for use in retrospective examination of COVID-19 trends and tracing SARS-CoV-2 variants and potentially other viruses, and provides a starting point for establishing a consistent procedure for specimen collection and storage for the WBE/WBS community.
Collapse
Affiliation(s)
- Isha Thapar
- Department of Environmental Science, Baylor University, One Bear Place #97266, Waco, TX 76798, USA
| | - Laura M Langan
- Department of Environmental Science, Baylor University, One Bear Place #97266, Waco, TX 76798, USA; Center for Reservoir and Aquatic Systems Research, Baylor University, One Bear Place #97178, Waco, TX 76798, USA.
| | - Haley Davis
- Department of Environmental Science, Baylor University, One Bear Place #97266, Waco, TX 76798, USA; Harbor Branch Oceanographic Institute, Florida Atlantic University, 5600 US-1, Fort Pierce, FL 34946, USA
| | - R Sean Norman
- Department of Environmental Health Sciences, Arnold School of Public Health, South Carolina, 921 Assembly St., Columbia, SC 29208, USA
| | - Heidi K Bojes
- Environmental Epidemiology and Disease Registries Section, Texas Department of State Health Services, Austin, TX 78756, USA
| | - Bryan W Brooks
- Department of Environmental Science, Baylor University, One Bear Place #97266, Waco, TX 76798, USA; Center for Reservoir and Aquatic Systems Research, Baylor University, One Bear Place #97178, Waco, TX 76798, USA; Institute of Biomedical Studies, Baylor University, One Bear Place #97224, Waco, TX 76798, USA
| |
Collapse
|
21
|
Rusková M, Bučková M, Puškárová A, Cíchová M, Janská V, Achs A, Šubr Z, Kuchta T, Pangallo D. Comparison of ordinary reverse transcription real-time polymerase chain reaction (qRT-PCR) with a newly developed one-step single-tube nested real-time RT-PCR (OSN-qRT-PCR) for sensitive detection of SARS-CoV-2 in wastewater. ENVIRONMENTAL SCIENCE AND POLLUTION RESEARCH INTERNATIONAL 2023; 30:95579-95589. [PMID: 37553492 PMCID: PMC10482794 DOI: 10.1007/s11356-023-29123-2] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 01/26/2023] [Accepted: 07/29/2023] [Indexed: 08/10/2023]
Abstract
Wastewater monitoring has proven to be an important approach to detecting and controlling the development of the SARS-CoV-2 pandemic. Various tests based on reverse transcription real-time PCR (qRT-PCR) have been developed and used for the detection of SARS-CoV-2 in wastewater samples. In this study, we attempted to increase the sensitivity of qRT-PCR by developing a one-step single-tube nested qRT-PCR assay (OSN-qRT-PCR). Two variants were developed, oriented to nucleocapsid phosphoprotein gene (N) and to spike protein gene (S), respectively. The performance of conventional qRT-PCR assays oriented to these genes with two novel OSN-qRT-PCR assays were firstly optimized using wastewater artificially contaminated with two encapsidated RNA mimic systems harboring a portion either N or S gene (ENRM and ESRM, respectively). The assays were coupled to a polyethylene glycol-based RNA precipitation/extraction method and applied to detect SARS-CoV-2 in wastewater samples from four cities in Slovakia. Both novel OSN-qRT-PCR assays demonstrated higher detection rates than the ordinary qRT-PCR counterparts. The virus levels in the analyzed wastewater samples had a high or very high relation with the numbers of clinical cases in the monitored regions. In fact, correlation with a 3-, 4-, or 5-day temporal offset was revealed. The OSN-qRT-PCR assays demonstrated robustness, mainly in samples with low viral loads.
Collapse
Affiliation(s)
- Magdaléna Rusková
- Institute of Molecular Biology, Slovak Academy of Sciences, Dúbravská Cesta 21, 845 51, Bratislava, Slovakia
| | - Mária Bučková
- Institute of Molecular Biology, Slovak Academy of Sciences, Dúbravská Cesta 21, 845 51, Bratislava, Slovakia
| | - Andrea Puškárová
- Institute of Molecular Biology, Slovak Academy of Sciences, Dúbravská Cesta 21, 845 51, Bratislava, Slovakia
| | - Marianna Cíchová
- Water Research Institute, Nábrežie Arm. Gen. L. Svobodu 5, 812 49, Bratislava, Slovakia
| | - Veronika Janská
- Water Research Institute, Nábrežie Arm. Gen. L. Svobodu 5, 812 49, Bratislava, Slovakia
| | - Adam Achs
- Biomedical Research Center, Slovak Academy of Sciences, Institute of Virology, Dúbravská Cesta 9, 845 05, Bratislava, Slovakia
| | - Zdeno Šubr
- Biomedical Research Center, Slovak Academy of Sciences, Institute of Virology, Dúbravská Cesta 9, 845 05, Bratislava, Slovakia
| | - Tomáš Kuchta
- Department of Microbiology, Molecular Biology and Biotechnology, Food Research Institute, National Agricultural and Food Centre, Priemyselná 4, 824 75, Bratislava, Slovakia
| | - Domenico Pangallo
- Institute of Molecular Biology, Slovak Academy of Sciences, Dúbravská Cesta 21, 845 51, Bratislava, Slovakia.
- Caravella, s.r.o., Tupolevova 2, 851 01, Bratislava, Slovakia.
| |
Collapse
|
22
|
Fuzzen M, Harper NBJ, Dhiyebi HA, Srikanthan N, Hayat S, Bragg LM, Peterson SW, Yang I, Sun JX, Edwards EA, Giesy JP, Mangat CS, Graber TE, Delatolla R, Servos MR. An improved method for determining frequency of multiple variants of SARS-CoV-2 in wastewater using qPCR assays. THE SCIENCE OF THE TOTAL ENVIRONMENT 2023; 881:163292. [PMID: 37030387 PMCID: PMC10079313 DOI: 10.1016/j.scitotenv.2023.163292] [Citation(s) in RCA: 6] [Impact Index Per Article: 6.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 11/16/2022] [Revised: 03/17/2023] [Accepted: 03/31/2023] [Indexed: 06/01/2023]
Abstract
Wastewater-based surveillance has become an effective tool around the globe for indirect monitoring of COVID-19 in communities. Variants of Concern (VOCs) have been detected in wastewater by use of reverse transcription polymerase chain reaction (RT-PCR) or whole genome sequencing (WGS). Rapid, reliable RT-PCR assays continue to be needed to determine the relative frequencies of VOCs and sub-lineages in wastewater-based surveillance programs. The presence of multiple mutations in a single region of the N-gene allowed for the design of a single amplicon, multiple probe assay, that can distinguish among several VOCs in wastewater RNA extracts. This approach which multiplexes probes designed to target mutations associated with specific VOC's along with an intra-amplicon universal probe (non-mutated region) was validated in singleplex and multiplex. The prevalence of each mutation (i.e. VOC) is estimated by comparing the abundance of the targeted mutation with a non-mutated and highly conserved region within the same amplicon. This is advantageous for the accurate and rapid estimation of variant frequencies in wastewater. The N200 assay was applied to monitor frequencies of VOCs in wastewater extracts from several communities in Ontario, Canada in near real time from November 28, 2021 to January 4, 2022. This includes the period of the rapid replacement of the Delta variant with the introduction of the Omicron variant in these Ontario communities in early December 2021. The frequency estimates using this assay were highly reflective of clinical WGS estimates for the same communities. This style of qPCR assay, which simultaneously measures signal from a non-mutated comparator probe and multiple mutation-specific probes contained within a single qPCR amplicon, can be applied to future assay development for rapid and accurate estimations of variant frequencies.
Collapse
Affiliation(s)
- Meghan Fuzzen
- Department of Biology, University of Waterloo, Waterloo, ON N2L 3G1, Canada.
| | | | - Hadi A Dhiyebi
- Department of Biology, University of Waterloo, Waterloo, ON N2L 3G1, Canada
| | - Nivetha Srikanthan
- Department of Biology, University of Waterloo, Waterloo, ON N2L 3G1, Canada
| | - Samina Hayat
- Department of Biology, University of Waterloo, Waterloo, ON N2L 3G1, Canada
| | - Leslie M Bragg
- Department of Biology, University of Waterloo, Waterloo, ON N2L 3G1, Canada
| | - Shelley W Peterson
- One-Health Division, Wastewater Surveillance Unit, National Microbiology Laboratory, Public Health Agency of Canada, Winnipeg, MB R3E 3M4, Canada
| | - Ivy Yang
- Chemical Engineering and Applied Chemistry, University of Toronto, Toronto, ON M5S 3E5, Canada
| | - J X Sun
- Chemical Engineering and Applied Chemistry, University of Toronto, Toronto, ON M5S 3E5, Canada
| | - Elizabeth A Edwards
- Chemical Engineering and Applied Chemistry, University of Toronto, Toronto, ON M5S 3E5, Canada
| | - John P Giesy
- Department of Veterinary Biomedical Sciences and Toxicology Centre, University of Saskatchewan, Saskatoon, SK S7N 5B3, Canada; Department of Environmental Sciences, Baylor University, Waco, TX, USA; Department of Zoology and Center for Integrative Toxicology, Michigan State University, East Lansing, MI, USA
| | - Chand S Mangat
- One-Health Division, Wastewater Surveillance Unit, National Microbiology Laboratory, Public Health Agency of Canada, Winnipeg, MB R3E 3M4, Canada
| | - Tyson E Graber
- Children's Hospital of Eastern Ontario Research Institute, Ottawa, Ontario K1H 8L1, Canada
| | - Robert Delatolla
- Department of Civil Engineering, University of Ottawa, Ottawa, Ontario K1N 6N5, Canada
| | - Mark R Servos
- Department of Biology, University of Waterloo, Waterloo, ON N2L 3G1, Canada
| |
Collapse
|
23
|
Reyes-Calderón A, Mindreau-Ganoza E, Pardo-Figueroa B, Garcia-Luquillas KR, Yufra SP, Romero PE, Antonini C, Renom JM, Mota CR, Santa-Maria MC. Evaluation of low-cost SARS-CoV-2 RNA purification methods for viral quantification by RT-qPCR and next-generation sequencing analysis: Implications for wider wastewater-based epidemiology adoption. Heliyon 2023; 9:e16130. [PMID: 37228686 PMCID: PMC10188194 DOI: 10.1016/j.heliyon.2023.e16130] [Citation(s) in RCA: 1] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/12/2022] [Revised: 04/09/2023] [Accepted: 05/06/2023] [Indexed: 05/27/2023] Open
Abstract
Based Epidemiology (WBE) consists of quantifying biomarkers in sewerage systems to derive real-time information on the health and/or lifestyle of the contributing population. WBE usefulness was vastly demonstrated in the context of the COVID-19 pandemic. Many methods for SARS-CoV-2 RNA determination in wastewater were devised, which vary in cost, infrastructure requirements and sensitivity. For most developing countries, implementing WBE for viral outbreaks, such as that of SARS-CoV-2, proved challenging due to budget, reagent availability and infrastructure constraints. In this study, we assessed low-cost methods for SARS-CoV-2 RNA quantification by RT-qPCR, and performed variant identification by NGS in wastewater samples. Results showed that the effect of adjusting pH to 4 and/or adding MgCl2 (25 mM) was negligible when using the adsorption-elution method, as well as basal physicochemical parameters in the sample. In addition, results supported the standardized use of linear rather than plasmid DNA for a more accurate viral RT-qPCR estimation. The modified TRIzol-based purification method in this study yielded comparable RT-qPCR estimation to a column-based approach, but provided better NGS results, suggesting that column-based purification for viral analysis should be revised. Overall, this work provides evaluation of a robust, sensitive and cost-effective method for SARS-CoV-2 RNA analysis that could be implemented for other viruses, for a wider WEB adoption.
Collapse
Affiliation(s)
- Alonso Reyes-Calderón
- Centro de Investigación y Tecnología del Agua - CITA, Universidad de Ingenieria y Tecnologia – UTEC, Jr. Medrano Silva 165, Lima, 15063, Peru
| | - Elías Mindreau-Ganoza
- Facultad de Ciencias Biológicas, Universidad Nacional Mayor de San Marcos, Av. Germán Amézaga s/n, Lima, 15081, Peru
| | - Braulio Pardo-Figueroa
- Centro de Investigación y Tecnología del Agua - CITA, Universidad de Ingenieria y Tecnologia – UTEC, Jr. Medrano Silva 165, Lima, 15063, Peru
| | - Katherine R. Garcia-Luquillas
- Centro de Investigación y Tecnología del Agua - CITA, Universidad de Ingenieria y Tecnologia – UTEC, Jr. Medrano Silva 165, Lima, 15063, Peru
| | - Sonia P. Yufra
- Departamento de Ingeniería Metalúrgica e Ingeniería Ambiental, Universidad Nacional de San Agustín, Av. Independencia s/n, Arequipa, 04001, Peru
| | - Pedro E. Romero
- Facultad de Ciencias Biológicas, Universidad Nacional Mayor de San Marcos, Av. Germán Amézaga s/n, Lima, 15081, Peru
| | - Claudia Antonini
- Departamento de Ingeniería Industrial, Universidad de Ingenieria y Tecnologia - UTEC, Jr. Medrano Silva 165, Lima, 15063, Peru
| | - Jose-Miguel Renom
- Departamento de Ciencias, Universidad de Ingenieria y Tecnologia - UTEC, Jr. Medrano Silva 165, Lima, 15063, Peru
| | - Cesar R. Mota
- Departamento de Engenharia Sanitária e Ambiental, Escola de Engenharia, Universidade Federal de Minas Gerais (UFMG), Av. Antonio Carlos, Belo Horizonte, 6.627, 31270-901, Brazil
| | - Monica C. Santa-Maria
- Centro de Investigación y Tecnología del Agua - CITA, Universidad de Ingenieria y Tecnologia – UTEC, Jr. Medrano Silva 165, Lima, 15063, Peru
| |
Collapse
|
24
|
Tang L, Wu J, Liu R, Feng Z, Zhang Y, Zhao Y, Li Y, Yang K. Exploration on wastewater-based epidemiology of SARS-CoV-2: Mimic relative quantification with endogenous biomarkers as internal reference. Heliyon 2023; 9:e15705. [PMID: 37124340 PMCID: PMC10122556 DOI: 10.1016/j.heliyon.2023.e15705] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/01/2022] [Revised: 04/18/2023] [Accepted: 04/20/2023] [Indexed: 05/02/2023] Open
Abstract
Wastewater-based epidemiology has become a powerful surveillance tool for monitoring the pandemic of COVID-19. Although it is promising to quantitatively correlate the SARS-CoV-2 RNA concentration in wastewater with the incidence of community infection, there is still no consensus on whether the viral nucleic acid concentration in sewage should be normalized against the abundance of endogenous biomarkers and which biomarker should be used as a reference for the normalization. Here, several candidate endogenous reference biomarkers for normalization of SARS-CoV-2 signal in municipal sewage were evaluated. The human fecal indicator virus (crAssphage) is a promising candidate of endogenous reference biomarker for data normalization of both DNA and RNA viruses for its intrinsic viral nature and high and stable content in sewage. Without constructing standard curves, the relative quantification of sewage viral nucleic acid against the abundance of the reference biomarker can be used to correlate with community COVID-19 incidence, which was proved via mimic experiments by spiking pseudovirus of different concentrations in sewage samples. Dilution of pseudovirus-seeded wastewater did not affect the relative abundance of viral nucleic acid, demonstrating that relative quantification can overcome the sewage dilution effects caused by the greywater input, precipitation and/or groundwater infiltration. The process of concentration, recovery and detection of the endogenous biomarker was consistent with that of SARS-CoV-2 RNA. Thus, it is necessary to co-quantify the endogenous biomarker because it can be not only an internal reference for data normalization, but also a process control.
Collapse
Affiliation(s)
- Langjun Tang
- Department of Pharmaceutical & Biological Engineering, School of Chemical Engineering, Sichuan University, Chengdu 610065, China
| | - Jinyong Wu
- Department of Pharmaceutical & Biological Engineering, School of Chemical Engineering, Sichuan University, Chengdu 610065, China
| | - Rui Liu
- Department of Pharmaceutical & Biological Engineering, School of Chemical Engineering, Sichuan University, Chengdu 610065, China
| | - Zhongxi Feng
- Department of Pharmaceutical & Biological Engineering, School of Chemical Engineering, Sichuan University, Chengdu 610065, China
| | - Yanan Zhang
- Department of Pharmaceutical & Biological Engineering, School of Chemical Engineering, Sichuan University, Chengdu 610065, China
| | - Yingzhe Zhao
- Department of Pharmaceutical & Biological Engineering, School of Chemical Engineering, Sichuan University, Chengdu 610065, China
| | - Yonghong Li
- Department of Pharmaceutical & Biological Engineering, School of Chemical Engineering, Sichuan University, Chengdu 610065, China
| | - Kun Yang
- Department of Pharmaceutical & Biological Engineering, School of Chemical Engineering, Sichuan University, Chengdu 610065, China
| |
Collapse
|
25
|
Yang K, Guo J, Møhlenberg M, Zhou H. SARS-CoV-2 surveillance in medical and industrial wastewater-a global perspective: a narrative review. ENVIRONMENTAL SCIENCE AND POLLUTION RESEARCH INTERNATIONAL 2023; 30:63323-63334. [PMID: 36988799 PMCID: PMC10049894 DOI: 10.1007/s11356-023-26571-8] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 12/22/2022] [Accepted: 03/16/2023] [Indexed: 05/11/2023]
Abstract
The novel coronavirus SARS-CoV-2 has spread at an unprecedented rate since late 2019, leading to the global COVID-19 pandemic. During the pandemic, being able to detect SARS-CoV-2 in human populations with high coverage quickly is a huge challenge. As SARS-CoV-2 is excreted in human excreta and thus exposed to the aqueous environment through sewers, the goal is to develop an ideal, non-invasive, cost-effective epidemiological method for detecting SARS-CoV-2. Wastewater surveillance has gained widespread interest and is increasingly being investigated as an effective early warning tool for monitoring the spread and evolution of the virus. This review emphasizes important findings on SARS-CoV-2 wastewater-based epidemiology (WBE) in different continents and techniques used to detect SARS-CoV-2 in wastewater during the period 2020-2022. The results show that WBE is a valuable population-level method for monitoring SARS-CoV-2 and is a valuable early warning alert. It can assist policymakers in formulating relevant policies to avoid the negative impacts of early or delayed action. Such strategy can also help avoid unnecessary wastage of medical resources, rationalize vaccine distribution, assist early detection, and contain large-scale outbreaks.
Collapse
Affiliation(s)
- Kaiwen Yang
- College of Medical Technology, Chengdu University of Traditional Chinese Medicine, Liutai Road 1166, Wenjiang, Chengdu, 610000, China
| | - Jinlin Guo
- College of Medical Technology, Chengdu University of Traditional Chinese Medicine, Liutai Road 1166, Wenjiang, Chengdu, 610000, China
| | - Michelle Møhlenberg
- Department of Biomedicine, Høegh-Guldbergs Gade 10, Building 1115, DK-8000, Aarhus C, Denmark
| | - Hao Zhou
- College of Medical Technology, Chengdu University of Traditional Chinese Medicine, Liutai Road 1166, Wenjiang, Chengdu, 610000, China.
| |
Collapse
|
26
|
Dehghan Banadaki M, Torabi S, Strike WD, Noble A, Keck JW, Berry SM. Improving wastewater-based epidemiology performance through streamlined automation. JOURNAL OF ENVIRONMENTAL CHEMICAL ENGINEERING 2023; 11:109595. [PMID: 36875746 PMCID: PMC9970922 DOI: 10.1016/j.jece.2023.109595] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 11/01/2022] [Revised: 02/02/2023] [Accepted: 02/26/2023] [Indexed: 06/18/2023]
Abstract
Wastewater-based epidemiology (WBE) has enabled us to describe Severe Acute Respiratory Syndrome Coronavirus 2 (SARS-CoV-2) infections in populations. However, implementation of wastewater monitoring of SARS-CoV-2 is limited due to the need for expert staff, expensive equipment, and prolonged processing times. As WBE increases in scope (beyond SARS-CoV-2) and scale (beyond developed regions), there is a need to make WBE processes simpler, cheaper, and faster. We developed an automated workflow based on a simplified method termed exclusion-based sample preparation (ESP). Our automated workflow takes 40 min from raw wastewater to purified RNA, which is several times faster than conventional WBE methods. The total assay cost per sample/replicate is $6.50 which includes consumables and reagents for concentration, extraction, and RT-qPCR quantification. The assay complexity is reduced significantly, as extraction and concentration steps are integrated and automated. The high recovery efficiency of the automated assay (84.5 ± 25.4%) yielded an improved Limit of Detection (LoDAutomated=40 copies/mL) compared to the manual process (LoDManual=206 copies/mL), increasing analytical sensitivity. We validated the performance of the automated workflow by comparing it with the manual method using wastewater samples from several locations. The results from the two methods correlated strongly (r = 0.953), while the automated method was shown to be more precise. In 83% of the samples, the automated method showed lower variation between replicates, which is likely due to higher technical errors in the manual process e.g., pipetting. Our automated wastewater workflow can support the expansion of WBE in the fight against Coronavirus Disease of 2019 (COVID-19) and other epidemics.
Collapse
Affiliation(s)
| | - Soroosh Torabi
- Department of Mechanical Engineering, College of Engineering, University of Kentucky, United States
| | - William D Strike
- Department of Biomedical Engineering, College of Engineering, University of Kentucky, United States
| | - Ann Noble
- Department of Mechanical Engineering, College of Engineering, University of Kentucky, United States
| | - James W Keck
- Department of Family and Community Medicine, College of Medicine, University of Kentucky, United States
| | - Scott M Berry
- Department of Mechanical Engineering, College of Engineering, University of Kentucky, United States
- Department of Biomedical Engineering, College of Engineering, University of Kentucky, United States
| |
Collapse
|
27
|
Morón-López S, Riveira-Muñoz E, Urrea V, Gutiérrez-Chamorro L, Ávila-Nieto C, Noguera-Julian M, Carrillo J, Mitjà O, Mateu L, Massanella M, Ballana E, Martinez-Picado J. Comparison of Reverse Transcription (RT)-Quantitative PCR and RT-Droplet Digital PCR for Detection of Genomic and Subgenomic SARS-CoV-2 RNA. Microbiol Spectr 2023; 11:e0415922. [PMID: 36943067 PMCID: PMC10100669 DOI: 10.1128/spectrum.04159-22] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/25/2022] [Accepted: 02/24/2023] [Indexed: 03/23/2023] Open
Abstract
Most individuals acutely infected with severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) exhibit mild symptoms. However, 10 to 20% of those infected develop long-term symptoms, referred to as post-coronavirus disease 2019 (COVID-19) condition (PCC). One hypothesis is that PCC might be exacerbated by viral persistence in tissue sanctuaries. Therefore, the accurate detection and quantification of SARS-CoV-2 are not only necessary for viral load monitoring but also crucial for detecting long-term viral persistence and determining whether viral replication is occurring in tissue reservoirs. In this study, the sensitivity and robustness of reverse transcription (RT)-droplet digital PCR (ddPCR) and RT-quantitative PCR (qPCR) techniques have been compared for the detection and quantification of SARS-CoV-2 genomic and subgenomic RNAs from oropharyngeal swabs taken from confirmed SARS-CoV-2-positive, SARS-CoV-2-exposed, and nonexposed individuals as well as from samples from mice infected with SARS-CoV-2. Our data demonstrated that both techniques presented equivalent results in the mid- and high-viral-load ranges. Additionally, RT-ddPCR was more sensitive than RT-qPCR in the low-viral-load range, allowing the accurate detection of positive results in individuals exposed to the virus. Overall, these data suggest that RT-ddPCR might be an alternative to RT-qPCR for detecting low viral loads in samples and for assessing viral persistence in samples from individuals with PCC. IMPORTANCE We developed one-step reverse transcription (RT)-droplet digital PCR (ddPCR) protocols to detect SARS-CoV-2 RNA and compared them to the gold-standard RT-quantitative PCR (RT-qPCR) method. RT-ddPCR was more sensitive than RT-qPCR in the low-viral-load range, while both techniques were equivalent in the mid- and high-viral-load ranges. Overall, these results suggest that RT-ddPCR might be a viable alternative to RT-qPCR when it comes to detecting low viral loads in samples, which is a highly relevant issue for determining viral persistence in as-yet-unknown tissue reservoirs in individuals suffering from post-COVID conditions or long COVID.
Collapse
Affiliation(s)
- Sara Morón-López
- IrsiCaixa AIDS Research Institute, Badalona, Spain
- CIBER de Enfermedades Infecciosas, Madrid, Spain
| | | | - Victor Urrea
- IrsiCaixa AIDS Research Institute, Badalona, Spain
| | | | | | - Marc Noguera-Julian
- IrsiCaixa AIDS Research Institute, Badalona, Spain
- CIBER de Enfermedades Infecciosas, Madrid, Spain
| | - Jorge Carrillo
- IrsiCaixa AIDS Research Institute, Badalona, Spain
- CIBER de Enfermedades Infecciosas, Madrid, Spain
- Germans Trias i Pujol Research Institute (IGTP), Badalona, Spain
| | - Oriol Mitjà
- Fight Infections Foundation, Badalona, Spain
- Hospital Universitari Germans Trias i Pujol, Badalona, Spain
- University of Vic-Central University of Catalonia (UVic-UCC), Vic, Spain
- Lihir Medical Centre, International SOS, Londolovit, Lihir Island, Papua New Guinea
| | - Lourdes Mateu
- Fight Infections Foundation, Badalona, Spain
- Hospital Universitari Germans Trias i Pujol, Badalona, Spain
- University of Vic-Central University of Catalonia (UVic-UCC), Vic, Spain
- Autonomous University of Barcelona (UAB), Barcelona, Spain
| | - Marta Massanella
- IrsiCaixa AIDS Research Institute, Badalona, Spain
- CIBER de Enfermedades Infecciosas, Madrid, Spain
- University of Vic-Central University of Catalonia (UVic-UCC), Vic, Spain
| | - Ester Ballana
- IrsiCaixa AIDS Research Institute, Badalona, Spain
- Germans Trias i Pujol Research Institute (IGTP), Badalona, Spain
| | - Javier Martinez-Picado
- IrsiCaixa AIDS Research Institute, Badalona, Spain
- CIBER de Enfermedades Infecciosas, Madrid, Spain
- Germans Trias i Pujol Research Institute (IGTP), Badalona, Spain
- University of Vic-Central University of Catalonia (UVic-UCC), Vic, Spain
- Catalan Institution for Research and Advanced Studies (ICREA), Barcelona, Spain
| |
Collapse
|
28
|
Davis A, Keely SP, Brinkman NE, Bohrer Z, Ai Y, Mou X, Chattopadhyay S, Hershey O, Senko J, Hull N, Lytmer E, Quintero A, Lee J. Evaluation of intra- and inter-lab variability in quantifying SARS-CoV-2 in a state-wide wastewater monitoring network. ENVIRONMENTAL SCIENCE : WATER RESEARCH & TECHNOLOGY 2023; 9:1053-1068. [PMID: 37701755 PMCID: PMC10494892 DOI: 10.1039/d2ew00737a] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 09/14/2023]
Abstract
In December 2019, SARS-CoV-2, the virus that causes coronavirus disease 2019, was first reported and subsequently triggered a global pandemic. Wastewater monitoring, a strategy for quantifying viral gene concentrations from wastewater influents within a community, has served as an early warning and management tool for the spread of SARS-CoV-2 in a community. Ohio built a collaborative statewide wastewater monitoring network that is supported by eight labs (university, government, and commercial laboratories) with unique sample processing workflows. Consequently, we sought to characterize the variability in wastewater monitoring results for network labs. Across seven trials between October 2020 and November 2021, eight participating labs successfully quantified two SARS-CoV-2 RNA targets and human fecal indicator virus targets in wastewater sample aliquots with reproducible results, although recovery efficiencies of spiked surrogates ranged from 3 to 75%. When SARS-CoV-2 gene fragment concentrations were adjusted for recovery efficiency and flow, the proportion of variance between laboratories was minimized, serving as the best model to account for between-lab variance. Another adjustment factor (alone and in different combinations with the above factors) considered to account for sample and measurement variability includes fecal marker normalization. Genetic quantification variability can be attributed to many factors, including the methods, individual samples, and water quality parameters. In addition, statistically significant correlations were observed between SARS-CoV-2 RNA and COVID-19 case numbers, supporting the notion that wastewater surveillance continues to serve as an effective monitoring tool. This study serves as a real-time example of multi-laboratory collaboration for public health preparedness for infectious diseases.
Collapse
Affiliation(s)
- Angela Davis
- Division of Environmental Health Sciences, College of Public Health, The Ohio State University, 1841 Neil Avenue, Columbus, OH 43210, USA
| | - Scott P Keely
- United States Environmental Protection Agency, Office of Research and Development, USA
| | - Nichole E Brinkman
- United States Environmental Protection Agency, Office of Research and Development, USA
| | | | - Yuehan Ai
- Department of Food Science & Technology, The Ohio State University, USA
| | - Xiaozhen Mou
- Department of Biological Sciences, Kent State University, USA
| | - Saurabh Chattopadhyay
- Department of Medical Microbiology and Immunology, College of Medicine and Life Sciences, Department of Biology and Department of Geosciences, University of Toledo, USA
| | - Olivia Hershey
- Department of Geosciences and Biology, University of Akron, USA
| | - John Senko
- Department of Geosciences and Biology, University of Akron, USA
| | - Natalie Hull
- Department of Civil, Environmental and Geodetic Engineering and Sustainability Institute, The Ohio State University, USA
| | - Eva Lytmer
- Department of Biological Sciences, Bowling Green State University, USA
| | | | - Jiyoung Lee
- Division of Environmental Health Sciences, College of Public Health, The Ohio State University, 1841 Neil Avenue, Columbus, OH 43210, USA
- Department of Food Science & Technology, The Ohio State University, USA
- Infectious Diseases Institute, The Ohio State University, USA
| |
Collapse
|
29
|
Zahmatkesh S, Rezakhani Y, Chofreh AG, Karimian M, Wang C, Ghodrati I, Hasan M, Sillanpaa M, Panchal H, Khan R. SARS-CoV-2 removal by mix matrix membrane: A novel application of artificial neural network based simulation in MATLAB for evaluating wastewater reuse risks. CHEMOSPHERE 2023; 310:136837. [PMID: 36252897 PMCID: PMC9560862 DOI: 10.1016/j.chemosphere.2022.136837] [Citation(s) in RCA: 9] [Impact Index Per Article: 9.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 07/27/2022] [Revised: 09/20/2022] [Accepted: 10/07/2022] [Indexed: 05/09/2023]
Abstract
The COVID-19 outbreak led to the discovery of SARS-CoV-2 in sewage; thus, wastewater treatment plants (WWTPs) could have the virus in their effluent. However, whether SARS-CoV-2 is eradicated by sewage treatment is virtually unknown. Specifically, the objectives of this study include (i) determining whether a mixed matrixed membrane (MMM) is able to remove SARS-CoV-2 (polycarbonate (PC)-hydrous manganese oxide (HMO) and PC-silver nanoparticles (Ag-NP)), (ii) comparing filtration performance among different secondary treatment processes, and (iii) evaluating whether artificial neural networks (ANNs) can be employed as performance indicators to reduce SARS-CoV-2 in the treatment of sewage. At Shariati Hospital in Mashhad, Iran, secondary treatment effluent during the outbreak of COVID-19 was collected from a WWTP. There were two PC-Ag-NP and PC-HMO processes at the WWTP targeted. RT-qPCR was employed to detect the presence of SARS-CoV-2 in sewage fractions. For the purposes of determining SARS-CoV-2 prevalence rates in the treated effluent, 10 L of effluent specimens were collected in middle-risk and low-risk treatment MMMs. For PC-HMO, the log reduction value (LRV) for SARS-CoV-2 was 1.3-1 log10 for moderate risk and 0.96-1 log10 for low risk, whereas for PC-Ag-NP, the LRV was 0.99-1.3 log10 for moderate risk and 0.94-0.98 log10 for low risk. MMMs demonstrated the most robust absorption performance during the sampling period, with the least significant LRV recorded in PC-Ag-NP and PC-HMO at 0.94 log10 and 0.96 log10, respectively.
Collapse
Affiliation(s)
- Sasan Zahmatkesh
- Department of Chemical Engineering, University of Science and Technology of Mazandaran, P.O. Box 48518-78195, Behshahr, Iran; Tecnologico de Monterrey, Escuela de Ingenieríay Ciencias, Puebla, Mexico.
| | - Yousof Rezakhani
- Department of Civil Engineering, Pardis Branch, Islamic Azad University, Pardis, Iran
| | - Abdoulmohammad Gholamzadeh Chofreh
- Sustainable Process Integration Laboratory, SPIL, NETME Centre, Faculty of Mechanical Engineering, Brno University of Technology, VUT Brno, Technická 2896/2, 616 00, Brno, Czech Republic
| | - Melika Karimian
- Faculty of Civil Engineering, Architecture and Urban Planning, University of Eyvanekey, Iran
| | - Chongqing Wang
- School of Chemical Engineering, Zhengzhou University, Zhengzhou, 450001, China
| | - Iman Ghodrati
- Department of Computer Engineering, Bojnourd Branch, Islamic Azad University, Bojnourd, Iran
| | - Mudassir Hasan
- Department of Chemical Engineering, College of Engineering, King Khalid University, Abha, 61411, Saudi Arabia
| | - Mika Sillanpaa
- Faculty of Science and Technology, School of Applied Physics, University Kebangsaan Malaysia, 43600, Bangi, Selangor, Malaysia; International Research Centre of Nanotechnology for Himalayan Sustainability (IRCNHS), Shoolini University, Solan, 173212, Himachal Pradesh, India; Department of Chemical Engineering, School of Mining, Metallurgy and Chemical Engineering, University of Johannesburg, P. O. Box 17011, Doornfontein, 2028, South Africa
| | - Hitesh Panchal
- Mechanical Engineering Department, Government Engineering College, Patan, Gujarat, India
| | - Ramsha Khan
- Faculty of Civil Engineering, Institute of Technology, Shri Ramswaroop Memorial University, Barabanki, 225003, UP, India
| |
Collapse
|
30
|
McMinn BR, Korajkic A, Pemberton AC, Kelleher J, Ahmed W, Villegas EN, Oshima K. Assessment of two volumetrically different concentration approaches to improve sensitivities for SARS-CoV-2 detection during wastewater monitoring. J Virol Methods 2023; 311:114645. [PMID: 36332716 PMCID: PMC9624105 DOI: 10.1016/j.jviromet.2022.114645] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/13/2022] [Accepted: 10/31/2022] [Indexed: 11/06/2022]
Abstract
Wastewater monitoring for severe acute respiratory syndrome coronavirus type 2 (SARS-CoV-2), the virus responsible for the global coronavirus disease 2019 (COVID-19) pandemic, has highlighted the need for methodologies capable of assessing viral prevalence during periods of low population infection. To address this need, two volumetrically different, methodologically similar concentration approaches were compared for their abilities to detect viral nucleic acid and infectious SARS-CoV-2 signal from primary influent samples. For Method 1, 2 L of SARS-CoV-2 seeded wastewater was evaluated using a dead-end hollow fiber ultrafilter (D-HFUF) for primary concentration, followed by the CP Select™ for secondary concentration. For Method 2, 100 mL of SARS-CoV-2 seeded wastewater was evaluated using the CP Select™ procedure. Following D-HFUF concentration (Method 1), significantly lower levels of infectious SARS-CoV-2 were lost (P value range: 0.0398-0.0027) compared to viral gene copy (GC) levels detected by the US Centers for Disease Control (CDC) N1 and N2 reverse-transcriptase quantitative polymerase chain reaction (RT-qPCR) assays. Subsamples at different steps in the concentration process were also taken to better characterize the losses of SARS-CoV-2 during the concentration process. During the centrifugation step (prior to CP Select™ concentration), significantly higher losses (P value range: 0.0003 to <0.0001) occurred for SARS-CoV-2 GC levels compared to infectious virus for Method 1, while between the methods, significantly higher infectious viral losses were observed for Method 2 (P = 0.0002). When analyzing overall recovery of endogenous SARS-CoV-2 in wastewater samples, application of Method 1 improved assay sensitivities (P = <0.0001) compared with Method 2; this was especially evident during periods of lower COVID-19 case rates within the sewershed. This study describes a method which can successfully concentrate infectious SARS-CoV-2 and viral RNA from wastewater. Moreover, we demonstrated that large volume wastewater concentration provides additional sensitivity needed to improve SARS-CoV-2 detection, especially during low levels of community disease prevalence.
Collapse
Affiliation(s)
- Brian R. McMinn
- Office of Research and Development, United States Environmental Protection Agency, 26 West Martin Luther King Drive, Cincinnati, OH 45268 United States,Corresponding author
| | - Asja Korajkic
- Office of Research and Development, United States Environmental Protection Agency, 26 West Martin Luther King Drive, Cincinnati, OH 45268 United States
| | - Adin C. Pemberton
- Office of Research and Development, United States Environmental Protection Agency, 26 West Martin Luther King Drive, Cincinnati, OH 45268 United States
| | - Julie Kelleher
- Office of Research and Development, United States Environmental Protection Agency, 26 West Martin Luther King Drive, Cincinnati, OH 45268 United States
| | - Warish Ahmed
- CSIRO Land and Water, Ecosciences Precinct, 41 Boggo Road, QLD 4102, Australia
| | - Eric N. Villegas
- Office of Research and Development, United States Environmental Protection Agency, 26 West Martin Luther King Drive, Cincinnati, OH 45268 United States
| | - Kevin Oshima
- Office of Research and Development, United States Environmental Protection Agency, 26 West Martin Luther King Drive, Cincinnati, OH 45268 United States
| |
Collapse
|
31
|
D'Aoust PM, Tian X, Towhid ST, Xiao A, Mercier E, Hegazy N, Jia JJ, Wan S, Kabir MP, Fang W, Fuzzen M, Hasing M, Yang MI, Sun J, Plaza-Diaz J, Zhang Z, Cowan A, Eid W, Stephenson S, Servos MR, Wade MJ, MacKenzie AE, Peng H, Edwards EA, Pang XL, Alm EJ, Graber TE, Delatolla R. Wastewater to clinical case (WC) ratio of COVID-19 identifies insufficient clinical testing, onset of new variants of concern and population immunity in urban communities. THE SCIENCE OF THE TOTAL ENVIRONMENT 2022; 853:158547. [PMID: 36067855 PMCID: PMC9444156 DOI: 10.1016/j.scitotenv.2022.158547] [Citation(s) in RCA: 17] [Impact Index Per Article: 8.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 04/19/2022] [Revised: 07/10/2022] [Accepted: 09/01/2022] [Indexed: 05/14/2023]
Abstract
Clinical testing has been the cornerstone of public health monitoring and infection control efforts in communities throughout the COVID-19 pandemic. With the anticipated reduction of clinical testing as the disease moves into an endemic state, SARS-CoV-2 wastewater surveillance (WWS) will have greater value as an important diagnostic tool. An in-depth analysis and understanding of the metrics derived from WWS is required to interpret and utilize WWS-acquired data effectively (McClary-Gutierrez et al., 2021; O'Keeffe, 2021). In this study, the SARS-CoV-2 wastewater signal to clinical cases (WC) ratio was investigated across seven cities in Canada over periods ranging from 8 to 21 months. This work demonstrates that significant increases in the WC ratio occurred when clinical testing eligibility was modified to appointment-only testing, identifying a period of insufficient clinical testing (resulting in a reduction to testing access and a reduction in the number of daily tests) in these communities, despite increases in the wastewater signal. Furthermore, the WC ratio decreased significantly in 6 of the 7 studied locations, serving as a potential signal of the emergence of the Alpha variant of concern (VOC) in a relatively non-immunized community (40-60 % allelic proportion), while a more muted decrease in the WC ratio signaled the emergence of the Delta VOC in a relatively well-immunized community (40-60 % allelic proportion). Finally, a significant decrease in the WC ratio signaled the emergence of the Omicron VOC, likely because of the variant's greater effectiveness at evading immunity, leading to a significant number of new reported clinical cases, even when community immunity was high. The WC ratio, used as an additional monitoring metric, could complement clinical case counts and wastewater signals as individual metrics in its potential ability to identify important epidemiological occurrences, adding value to WWS as a diagnostic technology during the COVID-19 pandemic and likely for future pandemics.
Collapse
Affiliation(s)
- Patrick M D'Aoust
- Department of Civil Engineering, University of Ottawa, Ottawa, Canada
| | - Xin Tian
- Department of Civil Engineering, University of Ottawa, Ottawa, Canada
| | | | - Amy Xiao
- Department of Biological Engineering, Massachusetts Institute of Technology, Cambridge, MA, United States of America
| | - Elisabeth Mercier
- Department of Civil Engineering, University of Ottawa, Ottawa, Canada
| | - Nada Hegazy
- Department of Civil Engineering, University of Ottawa, Ottawa, Canada
| | - Jian-Jun Jia
- Department of Civil Engineering, University of Ottawa, Ottawa, Canada
| | - Shen Wan
- Department of Civil Engineering, University of Ottawa, Ottawa, Canada
| | - Md Pervez Kabir
- Department of Civil Engineering, University of Ottawa, Ottawa, Canada
| | - Wanting Fang
- Department of Civil Engineering, University of Ottawa, Ottawa, Canada
| | - Meghan Fuzzen
- Department of Biology, University of Waterloo, Waterloo, Canada
| | - Maria Hasing
- Department of Laboratory Medicine and Pathology, University of Alberta, Edmonton, Canada
| | - Minqing Ivy Yang
- Department of Chemical Engineering and Applied Chemistry, University of Toronto, Toronto, Canada
| | - Jianxian Sun
- Department of Chemistry, University of Toronto, Toronto, Canada
| | - Julio Plaza-Diaz
- Children's Hospital of Eastern Ontario Research Institute, Ottawa, Canada
| | - Zhihao Zhang
- Department of Civil Engineering, University of Ottawa, Ottawa, Canada
| | - Aaron Cowan
- Department of Civil Engineering, University of Ottawa, Ottawa, Canada
| | - Walaa Eid
- Children's Hospital of Eastern Ontario Research Institute, Ottawa, Canada
| | - Sean Stephenson
- Children's Hospital of Eastern Ontario Research Institute, Ottawa, Canada
| | - Mark R Servos
- Department of Biology, University of Waterloo, Waterloo, Canada
| | - Matthew J Wade
- Data, Analytics and Surveillance Group, UK Health Security Agency, London, United Kingdom
| | - Alex E MacKenzie
- Children's Hospital of Eastern Ontario Research Institute, Ottawa, Canada
| | - Hui Peng
- Department of Chemistry, University of Toronto, Toronto, Canada
| | - Elizabeth A Edwards
- Department of Chemical Engineering and Applied Chemistry, University of Toronto, Toronto, Canada
| | - Xiao-Li Pang
- Department of Laboratory Medicine and Pathology, University of Alberta, Edmonton, Canada
| | - Eric J Alm
- Department of Biological Engineering, Massachusetts Institute of Technology, Cambridge, MA, United States of America
| | - Tyson E Graber
- Children's Hospital of Eastern Ontario Research Institute, Ottawa, Canada
| | - Robert Delatolla
- Department of Civil Engineering, University of Ottawa, Ottawa, Canada.
| |
Collapse
|
32
|
Wurtzer S, Levert M, Dhenain E, Accrombessi H, Manco S, Fagour N, Goulet M, Boudaud N, Gaillard L, Bertrand I, Challant J, Masnada S, Azimi S, Gillon-Ritz M, Robin A, Mouchel JM, Sig O, Moulin L. From Alpha to Omicron BA.2: New digital RT-PCR approach and challenges for SARS-CoV-2 VOC monitoring and normalization of variant dynamics in wastewater. THE SCIENCE OF THE TOTAL ENVIRONMENT 2022; 848:157740. [PMID: 35917966 PMCID: PMC9338838 DOI: 10.1016/j.scitotenv.2022.157740] [Citation(s) in RCA: 10] [Impact Index Per Article: 5.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 04/03/2022] [Revised: 07/26/2022] [Accepted: 07/27/2022] [Indexed: 05/17/2023]
Abstract
Throughout the COVID-19 pandemic, new variants have continuously emerged and spread in populations. Among these, variants of concern (VOC) have been the main culprits of successive epidemic waves, due to their transmissibility, pathogenicity or ability to escape the immune response. Quantification of the SARS-CoV-2 genomes in raw wastewater is a reliable approach well-described and widely deployed worldwide to monitor the spread of SARS-CoV-2 in human populations connected to sewage systems. Discrimination of VOCs in wastewater is also a major issue and can be achieved by genome sequencing or by detection of specific mutations suggesting the presence of VOCs. This study aimed to date the emergence of these VOCs (from Alpha to Omicron BA.2) by monitoring wastewater from the greater Paris area, France, but also to model the propagation dynamics of these VOCs and to characterize the replacement kinetics of the prevalent populations. These dynamics were compared to various individual-centered public health data, such as regional incidence and the proportions of VOCs identified by sequencing of strains isolated from patient. The viral dynamics in wastewater highlighted the impact of the vaccination strategy on the viral circulation within human populations but also suggested its potential effect on the selection of variants most likely to be propagated in immunized populations. Normalization of concentrations to capture population movements appeared statistically more reliable using variations in local drinking water consumption rather than using PMMoV concentrations because PMMoV fecal shedding was subject to variability and was not sufficiently relevant in this study. The dynamics of viral spread was observed earlier (about 13 days on the wave related to Omicron VOC) in raw wastewater than the regional incidence alerting to a possible risk of decorrelation between incidence and actual virus circulation probably resulting from a lower severity of infection in vaccinated populations.
Collapse
Affiliation(s)
- Sebastien Wurtzer
- Eau de Paris, Research & Development, 33 avenue Jean Jaures, FR-94200 Ivry sur Seine, France.
| | - Morgane Levert
- Sorbonne Universite, CNRS, EPHE, UMR 7619 Metis, e-LTER Zone Atelier Seine, F-75005 Paris, France
| | - Eloïse Dhenain
- Sorbonne Universite, CNRS, EPHE, UMR 7619 Metis, e-LTER Zone Atelier Seine, F-75005 Paris, France
| | - Heberte Accrombessi
- Eau de Paris, Research & Development, 33 avenue Jean Jaures, FR-94200 Ivry sur Seine, France
| | - Sandra Manco
- Eau de Paris, Research & Development, 33 avenue Jean Jaures, FR-94200 Ivry sur Seine, France
| | - Nathalie Fagour
- Eau de Paris, Research & Development, 33 avenue Jean Jaures, FR-94200 Ivry sur Seine, France
| | - Marion Goulet
- Eau de Paris, Research & Development, 33 avenue Jean Jaures, FR-94200 Ivry sur Seine, France
| | | | - Lucie Gaillard
- ACTALIA, Food Safety Department, F-50000 Saint-Lô, France
| | | | - Julie Challant
- University of Lorraine, CNRS, LCPME, F-54000 Nancy, France
| | - Sophie Masnada
- SIAM - STV, Avenue de la courtiere, FR-77400 Saint Thibault des vignes, France
| | - Sam Azimi
- SIAAP, Innovation Department, 82 Avenue Kléber, FR-92700 Colombes, France
| | - Miguel Gillon-Ritz
- Direction de la Proprete et de l'Eau - Service Technique de l'Eau et de l'Assainissement, Rue du Commandeur, FR-75014 Paris, France
| | - Alban Robin
- Eau de Paris, Research & Development, 33 avenue Jean Jaures, FR-94200 Ivry sur Seine, France
| | - Jean-Marie Mouchel
- Sorbonne Universite, CNRS, EPHE, UMR 7619 Metis, e-LTER Zone Atelier Seine, F-75005 Paris, France
| | - Obepine Sig
- Sorbonne Universite, CNRS, EPHE, UMR 7619 Metis, e-LTER Zone Atelier Seine, F-75005 Paris, France
| | - Laurent Moulin
- Eau de Paris, Research & Development, 33 avenue Jean Jaures, FR-94200 Ivry sur Seine, France
| |
Collapse
|
33
|
Ahmed W, Smith WJM, Metcalfe S, Jackson G, Choi PM, Morrison M, Field D, Gyawali P, Bivins A, Bibby K, Simpson SL. Comparison of RT-qPCR and RT-dPCR Platforms for the Trace Detection of SARS-CoV-2 RNA in Wastewater. ACS ES&T WATER 2022; 2:1871-1880. [PMID: 36380768 PMCID: PMC8848507 DOI: 10.1021/acsestwater.1c00387] [Citation(s) in RCA: 46] [Impact Index Per Article: 23.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/02/2023]
Abstract
We compared reverse transcription-quantitative polymerase chain reaction (RT-qPCR) and RT digital PCR (RT-dPCR) platforms for the trace detection of SARS-CoV-2 RNA in low-prevalence COVID-19 locations in Queensland, Australia, using CDC N1 and CDC N2 assays. The assay limit of detection (ALOD), PCR inhibition rates, and performance characteristics of each assay, along with the positivity rates with the RT-qPCR and RT-dPCR platforms, were evaluated by seeding known concentrations of exogenous SARS-CoV-2 in wastewater. The ALODs using RT-dPCR were approximately 2-5 times lower than those using RT-qPCR. During sample processing, the endogenous (n = 96) and exogenous (n = 24) SARS-CoV-2 wastewater samples were separated, and RNA was extracted from both wastewater eluates and pellets (solids). The RT-dPCR platform demonstrated a detection rate significantly greater than that of RT-qPCR for the CDC N1 and CDC N2 assays in the eluate (N1, p = 0.0029; N2, p = 0.0003) and pellet (N1, p = 0.0015; N2, p = 0.0067) samples. The positivity results also indicated that for the analysis of SARS-CoV-2 RNA in wastewater, including the eluate and pellet samples may further increase the detection sensitivity using RT-dPCR.
Collapse
Affiliation(s)
- Warish Ahmed
- CSIRO
Land and Water, Ecosciences Precinct, 41 Boggo Road, Dutton Park, QLD 4102, Australia
| | - Wendy J. M. Smith
- CSIRO
Land and Water, Ecosciences Precinct, 41 Boggo Road, Dutton Park, QLD 4102, Australia
| | - Suzanne Metcalfe
- CSIRO
Land and Water, Ecosciences Precinct, 41 Boggo Road, Dutton Park, QLD 4102, Australia
| | - Greg Jackson
- Water
Unit, Health Protection Branch, Prevention Division, Queensland Health, Brisbane, QLD 4001, Australia
| | - Phil M. Choi
- Water
Unit, Health Protection Branch, Prevention Division, Queensland Health, Brisbane, QLD 4001, Australia
| | - Mary Morrison
- Water
Unit, Health Protection Branch, Prevention Division, Queensland Health, Brisbane, QLD 4001, Australia
| | - Daniel Field
- Water
Unit, Health Protection Branch, Prevention Division, Queensland Health, Brisbane, QLD 4001, Australia
| | - Pradip Gyawali
- Institute
of Environmental Science and Research Ltd. (ESR), Porirua 5240, New Zealand
| | - Aaron Bivins
- Department
of Civil and Environmental Engineering and Earth Sciences, University of Notre Dame, Notre Dame, Indiana 46556, United States
| | - Kyle Bibby
- Department
of Civil and Environmental Engineering and Earth Sciences, University of Notre Dame, Notre Dame, Indiana 46556, United States
| | | |
Collapse
|
34
|
Ma D, Straathof J, Liu Y, Hull NM. Monitoring SARS-CoV-2 RNA in Wastewater with RT-qPCR and Chip-Based RT-dPCR: Sewershed-Level Trends and Relationships to COVID-19. ACS ES&T WATER 2022; 2:2084-2093. [PMID: 37552751 PMCID: PMC9173673 DOI: 10.1021/acsestwater.2c00055] [Citation(s) in RCA: 5] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 01/31/2022] [Revised: 05/10/2022] [Accepted: 05/11/2022] [Indexed: 08/10/2023]
Abstract
We evaluated the performance of reverse transcription quantitative PCR (uniplex and duplex RT-qPCR) and chip-based digital PCR (duplex RT-dPCR) using CDC N1 and CDC N2 assays for longitudinal monitoring of SARS-CoV-2 RNA in influent wastewater samples (n = 281) from three wastewater plants in Ohio from January 2021 to January 2022. Human fecal virus (PMMoV) and wastewater flow rate were used to normalize SARS-CoV-2 concentrations. SARS-CoV-2 measurements and COVID-19 cases were strongly correlated, but normalization effects on correlations varied between sewersheds. SARS-CoV-2 measurements by RT-qPCR were strongly correlated with 7-day moving average COVID-19 cases (average Spearman's ρ = 0.58, p < 0.05). SARS-CoV-2 was detected more frequently in samples with duplex RT-dPCR than with duplex RT-qPCR during periods of low COVID-19 cases. Duplex and uniplex RT-qPCR N1 concentrations were more strongly correlated with cases (ρ = 0.62) than N2 (ρ = 0.52). RT-dPCR correlations (average ρ = 0.21) were weaker than those of RT-qPCR (average ρ = 0.58). We also share practical experience from establishing wastewater surveillance. Per sample, RT-qPCR had a lower cost ($6 vs $18) and sample turnaround time (3-4 h vs 7-9 h) than RT-dPCR. These findings reinforce selection and use of PCR-based wastewater surveillance tools.
Collapse
Affiliation(s)
- Daniel Ma
- Department of Civil, Environmental and Geodetic
Engineering, The Ohio State University, Columbus, Ohio 43210,
United States
| | - Judith Straathof
- Department of Civil, Environmental and Geodetic
Engineering, The Ohio State University, Columbus, Ohio 43210,
United States
| | - Yijing Liu
- Department of Civil, Environmental and Geodetic
Engineering, The Ohio State University, Columbus, Ohio 43210,
United States
| | - Natalie Marie Hull
- Department of Civil, Environmental and Geodetic
Engineering, The Ohio State University, Columbus, Ohio 43210,
United States
- The Sustainability Institute, The Ohio
State University, Columbus, Ohio 43210, United
States
| |
Collapse
|
35
|
Nguyen Quoc B, Saingam P, RedCorn R, Carter JA, Jain T, Candry P, Gattuso M, Huang MLW, Greninger AL, Meschke JS, Bryan A, Winkler MKH. Case Study: Impact of Diurnal Variations and Stormwater Dilution on SARS-CoV-2 RNA Signal Intensity at Neighborhood Scale Wastewater Pumping Stations. ACS ES&T WATER 2022; 2:1964-1975. [PMID: 37552740 PMCID: PMC9261832 DOI: 10.1021/acsestwater.2c00016] [Citation(s) in RCA: 5] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 01/12/2022] [Revised: 06/09/2022] [Accepted: 06/10/2022] [Indexed: 05/14/2023]
Abstract
Wastewater based epidemiology (WBE) has emerged as a tool to track the spread of SARS-CoV-2. However, sampling at wastewater treatment plants (WWTPs) cannot identify transmission hotspots within a city. Here, we sought to understand the diurnal variations (24 h) in SARS-CoV-2 RNA titers at the neighborhood level, using pump stations that serve vulnerable communities (e.g., essential workers, more diverse communities). Hourly composite samples were collected from wastewater pump stations located in (i) a residential area and (ii) a shopping district. In the residential area, SARS-CoV-2 RNA concentration (N1, N2, and E assays) varied by up to 42-fold within a 24 h period. The highest viral load was observed between 5 and 7 am, when viral RNA was not diluted by stormwater. Normalizing peak concentrations during this time window with nutrient concentrations (N and P) enabled correcting for rainfall to connect sewage to clinical cases reported in the sewershed. Data from the shopping district pump station were inconsistent, probably due to the fluctuation of customers shopping at the mall. This work indicates pump stations serving the residential area offer a narrow time period of high signal intensity that could improve the sensitivity of WBE, and tracer compounds (N, P concentration) can be used to normalize SARS-CoV-2 signals during rainfall.
Collapse
Affiliation(s)
- Bao Nguyen Quoc
- Department of Civil and Environmental Engineering,
University of Washington, Seattle, Washington 98105,
United States
| | - Prakit Saingam
- Department of Civil and Environmental Engineering,
University of Washington, Seattle, Washington 98105,
United States
| | - Raymond RedCorn
- Department of Civil and Environmental Engineering,
University of Washington, Seattle, Washington 98105,
United States
| | - John A. Carter
- Department of Civil and Environmental Engineering,
University of Washington, Seattle, Washington 98105,
United States
| | - Tanisha Jain
- Department of Civil and Environmental Engineering,
University of Washington, Seattle, Washington 98105,
United States
| | - Pieter Candry
- Department of Civil and Environmental Engineering,
University of Washington, Seattle, Washington 98105,
United States
| | - Meghan Gattuso
- Seattle Public Utilities,
Seattle, Washington 98124, United States
| | - Meei-Li W. Huang
- Dept of Laboratory Medicine and Pathology,
University of Washington, Seattle, Washington 98105,
United States
| | - Alexander L. Greninger
- Dept of Laboratory Medicine and Pathology,
University of Washington, Seattle, Washington 98105,
United States
| | - John Scott Meschke
- Department of Environmental & Occupational Health
Sciences, University of Washington, Seattle, Washington 98105,
United States
| | - Andrew Bryan
- Dept of Laboratory Medicine and Pathology,
University of Washington, Seattle, Washington 98105,
United States
| | - Mari K. H. Winkler
- Department of Civil and Environmental Engineering,
University of Washington, Seattle, Washington 98105,
United States
| |
Collapse
|
36
|
Langan LM, O’Brien M, Rundell ZC, Back JA, Ryan BJ, Chambliss CK, Norman RS, Brooks BW. Comparative Analysis of RNA-Extraction Approaches and Associated Influences on RT-qPCR of the SARS-CoV-2 RNA in a University Residence Hall and Quarantine Location. ACS ES&T WATER 2022; 2:1929-1943. [PMID: 37552714 PMCID: PMC9063990 DOI: 10.1021/acsestwater.1c00476] [Citation(s) in RCA: 8] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 12/13/2021] [Revised: 04/11/2022] [Accepted: 04/12/2022] [Indexed: 05/09/2023]
Abstract
Wastewater-based epidemiology (WBE) provides an early warning and trend analysis approach for determining the presence of COVID-19 in a community and complements clinical testing in assessing the population level, even as viral loads fluctuate. Here, we evaluate combinations of two wastewater concentration methods (i.e., ultrafiltration and composite supernatant-solid), four pre-RNA extraction modifications, and three nucleic acid extraction kits using two different wastewater sampling locations. These consisted of a quarantine facility containing clinically confirmed COVID-19-positive inhabitants and a university residence hall. Of the combinations examined, composite supernatant-solid with pre-RNA extraction consisting of water concentration and RNA/DNA shield performed the best in terms of speed and sensitivity. Further, of the three nucleic acid extraction kits examined, the most variability was associated with the Qiagen kit. Focusing on the quarantine facility, viral concentrations measured in wastewater were generally significantly related to positive clinical cases, with the relationship dependent on method, modification, kit, target, and normalization, although results were variable-dependent on individual time points (Kendall's Tau-b (τ) = 0.17 to 0.6) or cumulatively (Kendall's Tau-b (τ) = -0.048 to 1). These observations can support laboratories establishing protocols to perform wastewater surveillance and monitoring efforts for COVID-19.
Collapse
Affiliation(s)
- Laura M. Langan
- Department of Environmental Science,
Baylor University, One Bear Place #97266, Waco, Texas 76798,
United States
- Center for Reservoir and Aquatic Systems Research,
Baylor University, One Bear Place #97178, Waco, Texas 76798,
United States
| | - Megan O’Brien
- Center for Reservoir and Aquatic Systems Research,
Baylor University, One Bear Place #97178, Waco, Texas 76798,
United States
| | - Zach C. Rundell
- Center for Reservoir and Aquatic Systems Research,
Baylor University, One Bear Place #97178, Waco, Texas 76798,
United States
| | - Jeffrey A. Back
- Center for Reservoir and Aquatic Systems Research,
Baylor University, One Bear Place #97178, Waco, Texas 76798,
United States
| | - Benjamin J. Ryan
- Department of Environmental Science,
Baylor University, One Bear Place #97266, Waco, Texas 76798,
United States
| | - C. Kevin Chambliss
- Center for Reservoir and Aquatic Systems Research,
Baylor University, One Bear Place #97178, Waco, Texas 76798,
United States
- Department of Chemistry and Biochemistry,
Baylor University, One Bear Place #97348, Waco, Texas 76798,
United States
| | - R. Sean Norman
- Environmental Health Sciences, Arnold
School of Public Health, South Carolina, 921 Assembly Street, Columbia,
South Carolina 29208, United States
| | - Bryan W. Brooks
- Department of Environmental Science,
Baylor University, One Bear Place #97266, Waco, Texas 76798,
United States
- Center for Reservoir and Aquatic Systems Research,
Baylor University, One Bear Place #97178, Waco, Texas 76798,
United States
- Institute of Biomedical Studies, Baylor
University, One Bear Place #97224, Waco, Texas 76798, United
States
| |
Collapse
|
37
|
Safford H, Zuniga-Montanez RE, Kim M, Wu X, Wei L, Sharpnack J, Shapiro K, Bischel HN. Wastewater-Based Epidemiology for COVID-19: Handling qPCR Nondetects and Comparing Spatially Granular Wastewater and Clinical Data Trends. ACS ES&T WATER 2022; 2:2114-2124. [PMID: 37552742 PMCID: PMC9397567 DOI: 10.1021/acsestwater.2c00053] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 01/31/2022] [Revised: 07/19/2022] [Accepted: 07/20/2022] [Indexed: 05/28/2023]
Abstract
Wastewater-based epidemiology (WBE) is a useful complement to clinical testing for managing COVID-19. While community-scale wastewater and clinical data frequently correlate, less is known about subcommunity relationships between the two data types. Moreover, nondetects in qPCR wastewater data are typically handled through methods known to bias results, overlooking perhaps better alternatives. We address these knowledge gaps using data collected from September 2020-June 2021 in Davis, California (USA). We hypothesize that coupling the expectation maximization (EM) algorithm with the Markov Chain Monte Carlo (MCMC) method could improve estimation of "missing" values in wastewater qPCR data. We test this hypothesis by applying EM-MCMC to city wastewater treatment plant data and comparing output to more conventional nondetect handling methods. Dissimilarities in results (i) underscore the importance of specifying nondetect handling method in reporting and (ii) suggest that using EM-MCMC may yield better agreement between community-scale clinical and wastewater data. We also present a novel framework for spatially aligning clinical data with wastewater data collected upstream of a treatment plant (i.e., distributed across a sewershed). Applying the framework to data from Davis reveals reasonable agreement between wastewater and clinical data at highly granular spatial scales-further underscoring the public-health value of WBE.
Collapse
Affiliation(s)
- Hannah Safford
- Department of Civil and Environmental Engineering,
University of California Davis, 3109 Ghausi Hall, 480 Bainer
Hall Drive, Davis, California 95616, United States
| | - Rogelio E. Zuniga-Montanez
- Department of Civil and Environmental Engineering,
University of California Davis, 3109 Ghausi Hall, 480 Bainer
Hall Drive, Davis, California 95616, United States
| | - Minji Kim
- School of Veterinary Medicine, University
of California Davis, Davis, California 95616, United
States
| | - Xiaoliu Wu
- Department of Statistics, University of
California Davis, Davis, California 95616, United
States
| | - Lifeng Wei
- Department of Statistics, University of
California Davis, Davis, California 95616, United
States
| | - James Sharpnack
- Department of Statistics, University of
California Davis, Davis, California 95616, United
States
| | - Karen Shapiro
- School of Veterinary Medicine, University
of California Davis, Davis, California 95616, United
States
| | - Heather N. Bischel
- Department of Civil and Environmental Engineering,
University of California Davis, 3109 Ghausi Hall, 480 Bainer
Hall Drive, Davis, California 95616, United States
| |
Collapse
|
38
|
Zhao L, Zou Y, Li Y, Miyani B, Spooner M, Gentry Z, Jacobi S, David RE, Withington S, McFarlane S, Faust R, Sheets J, Kaye A, Broz J, Gosine A, Mobley P, Busch AWU, Norton J, Xagoraraki I. Five-week warning of COVID-19 peaks prior to the Omicron surge in Detroit, Michigan using wastewater surveillance. THE SCIENCE OF THE TOTAL ENVIRONMENT 2022; 844:157040. [PMID: 35779714 PMCID: PMC9239917 DOI: 10.1016/j.scitotenv.2022.157040] [Citation(s) in RCA: 26] [Impact Index Per Article: 13.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 05/13/2022] [Revised: 06/24/2022] [Accepted: 06/24/2022] [Indexed: 04/14/2023]
Abstract
Wastewater-based epidemiology (WBE) is useful in predicting temporal fluctuations of COVID-19 incidence in communities and providing early warnings of pending outbreaks. To investigate the relationship between SARS-CoV-2 concentrations in wastewater and COVID-19 incidence in communities, a 12-month study between September 1, 2020, and August 31, 2021, prior to the Omicron surge, was conducted. 407 untreated wastewater samples were collected from the Great Lakes Water Authority (GLWA) in southeastern Michigan. N1 and N2 genes of SARS-CoV-2 were quantified using RT-ddPCR. Daily confirmed COVID-19 cases for the City of Detroit, and Wayne, Macomb, Oakland counties between September 1, 2020, and October 4, 2021, were collected from a public data source. The total concentrations of N1 and N2 genes ranged from 714.85 to 7145.98 gc/L and 820.47 to 6219.05 gc/L, respectively, which were strongly correlated with the 7-day moving average of total daily COVID-19 cases in the associated areas, after 5 weeks of the viral measurement. The results indicate a potential 5-week lag time of wastewater surveillance preceding COVID-19 incidence for the Detroit metropolitan area. Four statistical models were established to analyze the relationship between SARS-CoV-2 concentrations in wastewater and COVID-19 incidence in the study areas. Under a 5-week lag time scenario with both N1 and N2 genes, the autoregression model with seasonal patterns and vector autoregression model were more effective in predicting COVID-19 cases during the study period. To investigate the impact of flow parameters on the correlation, the original N1 and N2 gene concentrations were normalized by wastewater flow parameters. The statistical results indicated the optimum models were consistent for both normalized and non-normalized data. In addition, we discussed parameters that explain the observed lag time. Furthermore, we evaluated the impact of the omicron surge that followed, and the impact of different sampling methods on the estimation of lag time.
Collapse
Affiliation(s)
- Liang Zhao
- Department of Civil and Environmental Engineering, Michigan State University, 1449 Engineering Research Ct, East Lansing, MI 48823, United States of America
| | - Yangyang Zou
- Department of Civil and Environmental Engineering, Michigan State University, 1449 Engineering Research Ct, East Lansing, MI 48823, United States of America
| | - Yabing Li
- Department of Civil and Environmental Engineering, Michigan State University, 1449 Engineering Research Ct, East Lansing, MI 48823, United States of America
| | - Brijen Miyani
- Department of Civil and Environmental Engineering, Michigan State University, 1449 Engineering Research Ct, East Lansing, MI 48823, United States of America
| | - Maddie Spooner
- Department of Civil and Environmental Engineering, Michigan State University, 1449 Engineering Research Ct, East Lansing, MI 48823, United States of America
| | - Zachary Gentry
- Department of Civil and Environmental Engineering, Michigan State University, 1449 Engineering Research Ct, East Lansing, MI 48823, United States of America
| | - Sydney Jacobi
- Department of Civil and Environmental Engineering, Michigan State University, 1449 Engineering Research Ct, East Lansing, MI 48823, United States of America
| | - Randy E David
- Detroit Health Department, 100 Mack Ave, Detroit, MI 48201, United States of America
| | - Scott Withington
- Detroit Health Department, 100 Mack Ave, Detroit, MI 48201, United States of America
| | - Stacey McFarlane
- Macomb County Health Division, 43525 Elizabeth Rd, Mount Clemens, MI 48043, United States of America
| | - Russell Faust
- Oakland County Health Division, 1200 Telegraph Rd, Pontiac, MI 48341, United States of America
| | - Johnathon Sheets
- CDM-Smith, 535 Griswold St, Detroit, MI 48226, United States of America
| | - Andrew Kaye
- CDM-Smith, 535 Griswold St, Detroit, MI 48226, United States of America
| | - James Broz
- CDM-Smith, 535 Griswold St, Detroit, MI 48226, United States of America
| | - Anil Gosine
- Detroit Water and Sewerage Department, 735 Randolph Street building, Detroit, MI 48226, United States of America
| | - Palencia Mobley
- Detroit Water and Sewerage Department, 735 Randolph Street building, Detroit, MI 48226, United States of America
| | - Andrea W U Busch
- Great Lakes Water Authority, 735 Randolph, Detroit, MI 48226, United States of America
| | - John Norton
- Great Lakes Water Authority, 735 Randolph, Detroit, MI 48226, United States of America
| | - Irene Xagoraraki
- Department of Civil and Environmental Engineering, Michigan State University, 1449 Engineering Research Ct, East Lansing, MI 48823, United States of America.
| |
Collapse
|
39
|
Zheng X, Li S, Deng Y, Xu X, Ding J, Lau FTK, In Yau C, Poon LLM, Tun HM, Zhang T. Quantification of SARS-CoV-2 RNA in wastewater treatment plants mirrors the pandemic trend in Hong Kong. THE SCIENCE OF THE TOTAL ENVIRONMENT 2022; 844:157121. [PMID: 35787900 PMCID: PMC9249664 DOI: 10.1016/j.scitotenv.2022.157121] [Citation(s) in RCA: 13] [Impact Index Per Article: 6.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 04/11/2022] [Revised: 06/12/2022] [Accepted: 06/28/2022] [Indexed: 05/09/2023]
Abstract
Wastewater-based epidemiology (WBE) for the SARS-CoV-2 virus in wastewater treatment plants (WWTPs) has emerged as a cost-effective and unbiased tool for population-level testing in the community. In the present study, we conducted a 6-month wastewater monitoring campaign from three WWTPs of different flow rates and catchment area characteristics, which serve 28 % (2.1 million people) of Hong Kong residents in total. Wastewater samples collected daily or every other day were concentrated using ultracentrifugation and the SARS-CoV-2 virus RNA in the supernatant was detected using the N1 and E primer sets. The results showed significant correlations between the virus concentration and the number of daily new cases in corresponding catchment areas of the three WWTPs when using 7-day moving average values (Kendall's tau-b value: 0.227-0.608, p < 0.001). SARS-CoV-2 virus concentration was normalized to a fecal indicator using PMMoV concentration and daily flow rates, but the normalization did not enhance the correlation. The key factors contributing to the correlation were also evaluated, including the sampling frequency, testing methods, and smoothing days. This study demonstrates the applicability of wastewater surveillance to monitor overall SARS-CoV-2 pandemic dynamics in a densely populated city like Hong Kong, and provides a large-scale longitudinal reference for the establishment of the long-term sentinel surveillance in WWTPs for WBE of pathogens which could be combined into a city-wide public health observatory.
Collapse
Affiliation(s)
- Xiawan Zheng
- Environmental Microbiome Engineering and Biotechnology Lab, Center for Environmental Engineering Research, Department of Civil Engineering, The University of Hong Kong, Pokfulam Road, Hong Kong, China
| | - Shuxian Li
- Environmental Microbiome Engineering and Biotechnology Lab, Center for Environmental Engineering Research, Department of Civil Engineering, The University of Hong Kong, Pokfulam Road, Hong Kong, China
| | - Yu Deng
- Environmental Microbiome Engineering and Biotechnology Lab, Center for Environmental Engineering Research, Department of Civil Engineering, The University of Hong Kong, Pokfulam Road, Hong Kong, China
| | - Xiaoqing Xu
- Environmental Microbiome Engineering and Biotechnology Lab, Center for Environmental Engineering Research, Department of Civil Engineering, The University of Hong Kong, Pokfulam Road, Hong Kong, China
| | - Jiahui Ding
- Environmental Microbiome Engineering and Biotechnology Lab, Center for Environmental Engineering Research, Department of Civil Engineering, The University of Hong Kong, Pokfulam Road, Hong Kong, China
| | - Frankie T K Lau
- Drainage Services Department, The Government of the Hong Kong Special Administrative Region of the People's Republic of China, Wanchai, Hong Kong, China
| | - Chung In Yau
- School of Public Health, Li Ka Shing Faculty of Medicine, The University of Hong Kong, Sassoon Road, Hong Kong, China
| | - Leo L M Poon
- School of Public Health, Li Ka Shing Faculty of Medicine, The University of Hong Kong, Sassoon Road, Hong Kong, China
| | - Hein M Tun
- School of Public Health, Li Ka Shing Faculty of Medicine, The University of Hong Kong, Sassoon Road, Hong Kong, China
| | - Tong Zhang
- Environmental Microbiome Engineering and Biotechnology Lab, Center for Environmental Engineering Research, Department of Civil Engineering, The University of Hong Kong, Pokfulam Road, Hong Kong, China.
| |
Collapse
|
40
|
Kolarević S, Micsinai A, Szántó-Egész R, Lukács A, Kračun-Kolarević M, Djordjevic A, Vojnović-Milutinović D, Marić JJ, Kirschner AKT, Farnleitner AAH, Linke R, Đukic A, Kostić-Vuković J, Paunović M. Wastewater-based epidemiology in countries with poor wastewater treatment - Epidemiological indicator function of SARS-CoV-2 RNA in surface waters. THE SCIENCE OF THE TOTAL ENVIRONMENT 2022; 843:156964. [PMID: 35764146 PMCID: PMC9232394 DOI: 10.1016/j.scitotenv.2022.156964] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 03/14/2022] [Revised: 06/21/2022] [Accepted: 06/21/2022] [Indexed: 06/09/2023]
Abstract
Wastewater-based epidemiology (WBE) surveillance of COVID-19 and other future outbreaks is a challenge for developing countries as most households are not connected to a sewerage system. In December 2019, SARS-CoV-2 RNA was detected in the Danube River at a site severely affected by wastewaters from Belgrade. Rivers are much more complex systems than wastewater systems, and efforts are needed to address all the factors influencing the adoption of WBE as an alternative to targeting raw wastewater. Our objective was to provide a more detailed insight into the potential of SARS-CoV-2 surveillance in Serbian surface waters for epidemiological purposes. Water samples were collected at 12 sites along the Sava and Danube rivers in Belgrade during the fourth COVID-19 wave in Serbia that started in late February 2021. RNA was concentrated using Amicon Ultra-15 centrifugal filters and quantified using RT-qPCR with primer sets targeting nucleocapsid (N1 and N2) and envelope (E) protein genes. Microbiological (faecal indicator bacteria and human and animal genetic faecal source tracking markers), epidemiological, physicochemical and hydromorphological parameters were analysed in parallel. From 44 samples, SARS-CoV-2 RNA was detected in 31, but only at 4 concentrations above the level of quantification (ranging from 8.47 × 103 to 2.07 × 104 gc/L). The results indicated that surveillance of SARS-CoV-2 RNA in surface waters as ultimate recipients could be used as an epidemiological early-warning tool in countries lacking wastewater treatment and proper sewerage infrastructure. The performance of the applied approach, including advanced sampling site characterization to trace and identify sites with significant raw sewage influence from human populations, could be further improved by adaptation of the methodology for processing higher volumes of samples and enrichment factors, which should provide the quantitative instead of qualitative data needed for WBE.
Collapse
Affiliation(s)
- Stoimir Kolarević
- University of Belgrade, Institute for Biological Research "Siniša Stanković", National Institute of the Republic of Serbia, Bulevar despota Stefana 142, 11060 Belgrade, Serbia.
| | - Adrienn Micsinai
- WESSLING Hungary Ltd., Anonymous str 6., H-1045 Budapest, Hungary
| | | | - Alena Lukács
- Biomi Ltd., Szent-Györgyi Albert str 4, H-2100 Gödöllő, Hungary
| | - Margareta Kračun-Kolarević
- University of Belgrade, Institute for Biological Research "Siniša Stanković", National Institute of the Republic of Serbia, Bulevar despota Stefana 142, 11060 Belgrade, Serbia
| | - Ana Djordjevic
- University of Belgrade, Institute for Biological Research "Siniša Stanković", National Institute of the Republic of Serbia, Bulevar despota Stefana 142, 11060 Belgrade, Serbia
| | - Danijela Vojnović-Milutinović
- University of Belgrade, Institute for Biological Research "Siniša Stanković", National Institute of the Republic of Serbia, Bulevar despota Stefana 142, 11060 Belgrade, Serbia
| | - Jovana Jovanović Marić
- University of Belgrade, Institute for Biological Research "Siniša Stanković", National Institute of the Republic of Serbia, Bulevar despota Stefana 142, 11060 Belgrade, Serbia
| | - Alexander K T Kirschner
- Medical University Vienna, Institute for Hygiene and Applied Immunology - Water Microbiology, Kinderspitalgasse 15, Vienna, Austria; Interuniversity Cooperation Center Water and Health (ICC), Austria; Karl Landsteiner University of Health Sciences, Division Water Quality & Health, Dr.-Karl-Dorrek-Straße 30, A-3500 Krems, Austria
| | - Andreas A H Farnleitner
- Interuniversity Cooperation Center Water and Health (ICC), Austria; Karl Landsteiner University of Health Sciences, Division Water Quality & Health, Dr.-Karl-Dorrek-Straße 30, A-3500 Krems, Austria; Technische Universität Wien, Institute of Chemical, Environmental and Bioscience Engineering, Research Group for Microbiology and Molecular Diagnostics 166/5/3, Gumpendorferstraße 1a, A-1060 Vienna, Austria
| | - Rita Linke
- Interuniversity Cooperation Center Water and Health (ICC), Austria; Technische Universität Wien, Institute of Chemical, Environmental and Bioscience Engineering, Research Group for Microbiology and Molecular Diagnostics 166/5/3, Gumpendorferstraße 1a, A-1060 Vienna, Austria
| | - Aleksandar Đukic
- University of Belgrade, Faculty of Civil Engineering, Bulevar kralja Aleksandra 73, 11000 Belgrade, Serbia
| | - Jovana Kostić-Vuković
- University of Belgrade, Institute for Multidisciplinary Research, Department of Biology and Inland Water Protection, Kneza Višeslava 1, 11000 Belgrade, Serbia
| | - Momir Paunović
- University of Belgrade, Institute for Biological Research "Siniša Stanković", National Institute of the Republic of Serbia, Bulevar despota Stefana 142, 11060 Belgrade, Serbia
| |
Collapse
|
41
|
de Freitas Bueno R, Claro ICM, Augusto MR, Duran AFA, Camillo LDMB, Cabral AD, Sodré FF, Brandão CCS, Vizzotto CS, Silveira R, de Melo Mendes G, Arruda AF, de Brito NN, Machado BAS, Duarte GRM, de Lourdes Aguiar-Oliveira M. Wastewater-based epidemiology: A Brazilian SARS-COV-2 surveillance experience. JOURNAL OF ENVIRONMENTAL CHEMICAL ENGINEERING 2022; 10:108298. [PMID: 35873721 PMCID: PMC9295330 DOI: 10.1016/j.jece.2022.108298] [Citation(s) in RCA: 11] [Impact Index Per Article: 5.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 03/09/2022] [Revised: 07/05/2022] [Accepted: 07/17/2022] [Indexed: 05/11/2023]
Abstract
Since 2020, developed countries have rapidly shared both publicly and academically relevant wastewater surveillance information. Data on SARS-CoV-2 circulation is pivotal for guiding public health policies and improving the COVID-19 pandemic response. Conversely, low- and middle-income countries, such as Latin America and the Caribbean, showed timid activities in the Wastewater-Based Epidemiology (WBE) context. In these countries, isolated groups perform viral wastewater monitoring, and the data are unevenly shared or accessible to health agencies and the scientific community. This manuscript aims to highlight the relevance of a multiparty effort involving research, public health, and governmental agencies to support usage of WBE methodology to its full potential during the COVID-19 pandemic as part of a joint One Health surveillance approach. Thus, in this study, we explored the results obtained from wastewater surveillance in different regions of Brazil as a part of the COVID-19 Wastewater Monitoring Network ANA (National Water Agency), MCTI (Ministry of Science, Technology, and Innovations) and MS (Ministry of Health). Over the epidemiological weeks of 2021 and early 2022, viral RNA concentrations in wastewater followed epidemiological trends and variations. The highest viral loads in wastewater samples were detected during the second Brazilian wave of COVID-19. Corroborating international reports, our experience demonstrated usefulness of the WBE approach in viral surveillance. Wastewater surveillance allows hotspot identification, and therefore, early public health interventions. In addition, this methodology allows tracking of asymptomatic and oligosymptomatic individuals, who are generally underreported, especially in emerging countries with limited clinical testing capacity. Therefore, WBE undoubtedly contributes to improving public health responses in the context of this pandemic, as well as other sanitary emergencies.
Collapse
Affiliation(s)
- Rodrigo de Freitas Bueno
- Federal University of ABC. Center of Engineering, Modelling and Applied Social Sciences (CECS), Santo Andre, São Paulo, Brazil
| | - Ieda Carolina Mantovani Claro
- Federal University of ABC. Center of Engineering, Modelling and Applied Social Sciences (CECS), Santo Andre, São Paulo, Brazil
| | - Matheus Ribeiro Augusto
- Federal University of ABC. Center of Engineering, Modelling and Applied Social Sciences (CECS), Santo Andre, São Paulo, Brazil
| | - Adriana Feliciano Alves Duran
- Federal University of ABC. Center of Engineering, Modelling and Applied Social Sciences (CECS), Santo Andre, São Paulo, Brazil
| | | | - Aline Diniz Cabral
- Federal University of ABC. Center of Engineering, Modelling and Applied Social Sciences (CECS), Santo Andre, São Paulo, Brazil
| | | | | | - Carla Simone Vizzotto
- University of Brasilia, Department of Civil and Environmental Engineering, Brasília, Federal District, Brazil
| | - Rafaella Silveira
- University of Brasilia. Institute of Chemistry, Brasília, Federal District, Brazil
- University of Brasilia, Department of Civil and Environmental Engineering, Brasília, Federal District, Brazil
| | | | | | | | - Bruna Aparecida Souza Machado
- University Center SENAI/CIMATEC. SENAI Institute of Innovation (ISI) in Health Advanced Systems (CIMATEC ISI SAS), Salvador, Bahia, Brazil
| | | | - Maria de Lourdes Aguiar-Oliveira
- Laboratory of Respiratory Viruses and Measles, National/MoH and International/WHO Reference Laboratory in COVID-19, Oswaldo Cruz Institute, Fiocruz, Rio de Janeiro, Brazil
| |
Collapse
|
42
|
Lee L, Valmond L, Thomas J, Kim A, Austin P, Foster M, Matthews J, Kim P, Newman J. Wastewater surveillance in smaller college communities may aid future public health initiatives. PLoS One 2022; 17:e0270385. [PMID: 36112629 PMCID: PMC9481015 DOI: 10.1371/journal.pone.0270385] [Citation(s) in RCA: 4] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/08/2022] [Accepted: 09/01/2022] [Indexed: 11/26/2022] Open
Abstract
To date, the COVID-19 pandemic has resulted in over 570 million cases and over 6 million deaths worldwide. Predominant clinical testing methods, though invaluable, may create an inaccurate depiction of COVID-19 prevalence due to inadequate access, testing, or most recently under-reporting because of at-home testing. These concerns have created a need for unbiased, community-level surveillance. Wastewater-based epidemiology has been used for previous public health threats, and more recently has been established as a complementary method of SARS-CoV-2 surveillance. Here we describe the application of wastewater surveillance for SARS-CoV-2 in two university campus communities located in rural Lincoln Parish, Louisiana. This cost-effective approach is especially well suited to rural areas where limited access to testing may worsen the spread of COVID-19 and quickly exhaust the capacity of local healthcare systems. Our work demonstrates that local universities can leverage scientific resources to advance public health equity in rural areas and enhance their community involvement.
Collapse
Affiliation(s)
- Laura Lee
- School of Biological Sciences, Louisiana Tech University, Ruston, Louisiana, United States of America
| | - Lescia Valmond
- Department of Biology, Grambling State University, Grambling, Louisiana, United States of America
| | - John Thomas
- Department of Biology, Grambling State University, Grambling, Louisiana, United States of America
| | - Audrey Kim
- Department of Biology, Grambling State University, Grambling, Louisiana, United States of America
| | - Paul Austin
- School of Biological Sciences, Louisiana Tech University, Ruston, Louisiana, United States of America
| | - Michael Foster
- School of Biological Sciences, Louisiana Tech University, Ruston, Louisiana, United States of America
| | - John Matthews
- Trenchless Technology Center, Louisiana Tech University, Ruston, LA, United States of America
| | - Paul Kim
- Department of Biology, Grambling State University, Grambling, Louisiana, United States of America
| | - Jamie Newman
- School of Biological Sciences, Louisiana Tech University, Ruston, Louisiana, United States of America
| |
Collapse
|
43
|
Robins K, Leonard AFC, Farkas K, Graham DW, Jones DL, Kasprzyk-Hordern B, Bunce JT, Grimsley JMS, Wade MJ, Zealand AM, McIntyre-Nolan S. Research needs for optimising wastewater-based epidemiology monitoring for public health protection. JOURNAL OF WATER AND HEALTH 2022; 20:1284-1313. [PMID: 36170187 DOI: 10.2166/wh.2022.026] [Citation(s) in RCA: 6] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/16/2023]
Abstract
Wastewater-based epidemiology (WBE) is an unobtrusive method used to observe patterns in illicit drug use, poliovirus, and severe acute respiratory syndrome coronavirus-2 (SARS-CoV-2). The pandemic and need for surveillance measures have led to the rapid acceleration of WBE research and development globally. With the infrastructure available to monitor SARS-CoV-2 from wastewater in 58 countries globally, there is potential to expand targets and applications for public health protection, such as other viral pathogens, antimicrobial resistance (AMR), pharmaceutical consumption, or exposure to chemical pollutants. Some applications have been explored in academic research but are not used to inform public health decision-making. We reflect on the current knowledge of WBE for these applications and identify barriers and opportunities for expanding beyond SARS-CoV-2. This paper critically reviews the applications of WBE for public health and identifies the important research gaps for WBE to be a useful tool in public health. It considers possible uses for pathogenic viruses, AMR, and chemicals. It summarises the current evidence on the following: (1) the presence of markers in stool and urine; (2) environmental factors influencing persistence of markers in wastewater; (3) methods for sample collection and storage; (4) prospective methods for detection and quantification; (5) reducing uncertainties; and (6) further considerations for public health use.
Collapse
Affiliation(s)
- Katie Robins
- Environmental Monitoring for Health Protection, UK Health Security Agency, Nobel House, London SW1P 3HX, UK E-mail: ; School of Engineering, Newcastle University, Cassie Building, Newcastle-upon-Tyne NE1 7RU, UK
| | - Anne F C Leonard
- Environmental Monitoring for Health Protection, UK Health Security Agency, Nobel House, London SW1P 3HX, UK E-mail: ; University of Exeter Medical School, European Centre for Environment and Human Health, University of Exeter, Cornwall TR10 9FE, UK
| | - Kata Farkas
- School of Natural Sciences, Bangor University, Bangor, Gwynedd LL57 2UW, UK
| | - David W Graham
- School of Engineering, Newcastle University, Cassie Building, Newcastle-upon-Tyne NE1 7RU, UK
| | - David L Jones
- School of Natural Sciences, Bangor University, Bangor, Gwynedd LL57 2UW, UK; SoilsWest, Centre for Sustainable Farming Systems, Food Futures Institute, Murdoch University, Murdoch, WA 6105, Australia
| | | | - Joshua T Bunce
- Environmental Monitoring for Health Protection, UK Health Security Agency, Nobel House, London SW1P 3HX, UK E-mail: ; School of Engineering, Newcastle University, Cassie Building, Newcastle-upon-Tyne NE1 7RU, UK
| | - Jasmine M S Grimsley
- Environmental Monitoring for Health Protection, UK Health Security Agency, Nobel House, London SW1P 3HX, UK E-mail:
| | - Matthew J Wade
- Environmental Monitoring for Health Protection, UK Health Security Agency, Nobel House, London SW1P 3HX, UK E-mail: ; School of Engineering, Newcastle University, Cassie Building, Newcastle-upon-Tyne NE1 7RU, UK
| | - Andrew M Zealand
- Environmental Monitoring for Health Protection, UK Health Security Agency, Nobel House, London SW1P 3HX, UK E-mail:
| | - Shannon McIntyre-Nolan
- Environmental Monitoring for Health Protection, UK Health Security Agency, Nobel House, London SW1P 3HX, UK E-mail: ; Her Majesty's Prison and Probation Service, Ministry of Justice, London, SW1H 9AJ, UK
| |
Collapse
|
44
|
Tiwari A, Ahmed W, Oikarinen S, Sherchan SP, Heikinheimo A, Jiang G, Simpson SL, Greaves J, Bivins A. Application of digital PCR for public health-related water quality monitoring. THE SCIENCE OF THE TOTAL ENVIRONMENT 2022; 837:155663. [PMID: 35523326 DOI: 10.1016/j.scitotenv.2022.155663] [Citation(s) in RCA: 38] [Impact Index Per Article: 19.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 03/22/2022] [Revised: 04/28/2022] [Accepted: 04/29/2022] [Indexed: 05/25/2023]
Abstract
Digital polymerase chain reaction (dPCR) is emerging as a reliable platform for quantifying microorganisms in the field of water microbiology. This paper reviews the fundamental principles of dPCR and its application for health-related water microbiology. The relevant literature indicates increasing adoption of dPCR for measuring fecal indicator bacteria, microbial source tracking marker genes, and pathogens in various aquatic environments. The adoption of dPCR has accelerated recently due to increasing use for wastewater surveillance of Severe Acute Respiratory Coronavirus 2 (SARS-CoV-2) - the virus that causes Coronavirus Disease 2019 (COVID-19). The collective experience in the scientific literature indicates that well-optimized dPCR assays can quantify genetic material from microorganisms without the need for a calibration curve and often with superior analytical performance (i.e., greater sensitivity, precision, and reproducibility) than quantitative polymerase chain reaction (qPCR). Nonetheless, dPCR should not be viewed as a panacea for the fundamental uncertainties and limitations associated with measuring microorganisms in water microbiology. With dPCR platforms, the sample analysis cost and processing time are typically greater than qPCR. However, if improved analytical performance (i.e., sensitivity and accuracy) is critical, dPCR can be an alternative option for quantifying microorganisms, including pathogens, in aquatic environments.
Collapse
Affiliation(s)
- Ananda Tiwari
- Department of Food Hygiene and Environmental Health, Faculty of Veterinary Medicine, University of Helsinki, Finland
| | - Warish Ahmed
- CSIRO Land and Water, Ecosciences Precinct, Queensland, Australia
| | - Sami Oikarinen
- Faculty of Medicine and Health Technology, Tampere University, Tampere, Finland
| | - Samendra P Sherchan
- Department of Environmental Health Sciences, Tulane University, New Orleans, LA, USA; Department of Biology, Morgan State University, Baltimore, MD 21251, USA; BioEnvironmental Science Program, Department of Biology, Morgan State University, Baltimore, MD 21251, USA
| | - Annamari Heikinheimo
- Department of Food Hygiene and Environmental Health, Faculty of Veterinary Medicine, University of Helsinki, Finland; Finnish Food Authority, Seinäjoki, Finland
| | - Guangming Jiang
- School of Civil, Mining and Environmental Engineering, University of Wollongong, Australia; Illawarra Health and Medical Research Institute (IHMRI), University of Wollongong, Wollongong, Australia
| | | | - Justin Greaves
- School of Environmental Sustainability, Loyola University Chicago, 6364 N. Sheridan Rd, Chicago, IL 60660, USA
| | - Aaron Bivins
- Department of Civil & Environmental Engineering, Louisiana State University, LA, USA.
| |
Collapse
|
45
|
Yaniv K, Ozer E, Shagan M, Paitan Y, Granek R, Kushmaro A. Managing an evolving pandemic: Cryptic circulation of the Delta variant during the Omicron rise. THE SCIENCE OF THE TOTAL ENVIRONMENT 2022; 836:155599. [PMID: 35504376 PMCID: PMC9055682 DOI: 10.1016/j.scitotenv.2022.155599] [Citation(s) in RCA: 16] [Impact Index Per Article: 8.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 02/10/2022] [Revised: 04/11/2022] [Accepted: 04/25/2022] [Indexed: 05/18/2023]
Abstract
SARS-CoV-2 continued circulation results in mutations and the emergence of various variants. Until now, whenever a new, dominant, variant appeared, it overpowered its predecessor after a short parallel period. The latest variant of concern, Omicron, is spreading swiftly around the world with record morbidity reports. Unlike the Delta variant, previously considered to be the main variant of concern in most countries, including Israel, the dynamics of the Omicron variant showed different characteristics. To enable quick assessment of the spread of this variant we developed an RT-qPCR primers-probe set for the direct detection of Omicron variant. Characterized as highly specific and sensitive, the new Omicron detection set was deployed on clinical and wastewater samples. In contrast to the expected dynamics whereupon the Delta variant diminishes as Omicron variant increases, representative results received from wastewater detection indicated a cryptic circulation of the Delta variant even with the increased levels of Omicron variant. Resulting wastewater data illustrated the very initial Delta-Omicron dynamics occurring in real time. Despite this, the future development and dynamics of the two variants side-by-side is still mainly unknown. Based on the initial results, a double susceptible-infected-recovered model was developed for the Delta and Omicron variants. According to the developed model, it can be expected that the Omicron levels will decrease until eliminated, while Delta variant will maintain its cryptic circulation. If this comes to pass, the mentioned cryptic circulation may result in the reemergence of a Delta morbidity wave or in the possible generation of a new threatening variant. In conclusion, the deployment of wastewater-based epidemiology is recommended as a convenient and representative tool for pandemic containment.
Collapse
Affiliation(s)
- Karin Yaniv
- Avram and Stella Goldstein-Goren Department of Biotechnology Engineering, Ben-Gurion University of the Negev, Beer-Sheva 84105, Israel
| | - Eden Ozer
- Department of Life Sciences, Ben-Gurion University of the Negev, Beer-Sheva 84105, Israel
| | - Marilou Shagan
- Avram and Stella Goldstein-Goren Department of Biotechnology Engineering, Ben-Gurion University of the Negev, Beer-Sheva 84105, Israel
| | - Yossi Paitan
- Ilex Labs, Ilex Medical Ltd, 7 Hatnufa St., Petach-Tikva 4951025, Israel
| | - Rony Granek
- Avram and Stella Goldstein-Goren Department of Biotechnology Engineering, Ben-Gurion University of the Negev, Beer-Sheva 84105, Israel; The Ilse Katz Center for Nanoscale Science and Technology, Ben-Gurion University of the Negev, Beer Sheva 84105, Israel
| | - Ariel Kushmaro
- Avram and Stella Goldstein-Goren Department of Biotechnology Engineering, Ben-Gurion University of the Negev, Beer-Sheva 84105, Israel; The Ilse Katz Center for Nanoscale Science and Technology, Ben-Gurion University of the Negev, Beer Sheva 84105, Israel; School of Sustainability and Climate Change, Ben-Gurion University of the Negev, Beer-Sheva 84105, Israel.
| |
Collapse
|
46
|
Rusková M, Bučková M, Achs A, Puškárová A, Wu JH, Kuchta T, Šubr Z, Pangallo D. Useful molecular tools for facing next pandemic events: Effective sample preparation and improved RT-PCR for highly sensitive detection of SARS-CoV-2 in wastewater environment. Int J Hyg Environ Health 2022; 245:114017. [PMID: 35939897 PMCID: PMC9346026 DOI: 10.1016/j.ijheh.2022.114017] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/14/2022] [Revised: 06/22/2022] [Accepted: 07/27/2022] [Indexed: 10/28/2022]
Abstract
Viral pandemics can be inevitable in the next future. Considering SARS-CoV-2 pandemics as an example, there seems to be a need to develop a surveillance system able to monitor the presence of potential pathogenic agents. The sewage and wastewater environments demonstrated to be suitable targets for such kind of analysis. In addition, it is important to have reliable molecular diagnostic tools and also to develop a robust detection strategy. In this study, an effective sample preparation procedure was selected from four options and combined with a newly developed improved RT-PCR. First, a model viral system was constructed, containing a fragment of the SARS-CoV-2 gene encoding for the Spike protein. The encapsidated S RNA mimic (ESRM) was based on the plum pox virus (PPV) genome with the inserted targeted gene fragment. ESRM was used for seeding wastewater samples in order to evaluate the viral recovery of four different viral RNA concentration/extraction methods. The efficiency of individual approaches was assessed by the use of a quantitative reverse transcription PCR (qRT-PCR) and by a one-step single-tube nested quantitative reverse transcription PCR (OSN-qRT-PCR). For the detection of viruses in wastewater samples with low viral loads, OSN-qRT-PCR assay produced the most satisfactory results and the highest sensitivity.
Collapse
Affiliation(s)
- Magdaléna Rusková
- Institute of Molecular Biology, Slovak Academy of Sciences, Dúbravská cesta 21, 845 51, Bratislava, Slovakia
| | - Mária Bučková
- Institute of Molecular Biology, Slovak Academy of Sciences, Dúbravská cesta 21, 845 51, Bratislava, Slovakia
| | - Adam Achs
- Biomedical Research Center, Slovak Academy of Sciences, Institute of Virology. Dúbravská cesta 9, 845 05, Bratislava, Slovakia
| | - Andrea Puškárová
- Institute of Molecular Biology, Slovak Academy of Sciences, Dúbravská cesta 21, 845 51, Bratislava, Slovakia
| | - Jer-Horng Wu
- National Cheng Kung University, Department of Environmental Engineering. University Road 1, East District, 701 01, Tainan City, Taiwan
| | - Tomáš Kuchta
- Department of Microbiology, Molecular Biology and Biotechnology, Food Research Institute, National Agricultural and Food Centre, Priemyselná 4, 824 75, Bratislava, Slovakia
| | - Zdeno Šubr
- Biomedical Research Center, Slovak Academy of Sciences, Institute of Virology. Dúbravská cesta 9, 845 05, Bratislava, Slovakia
| | - Domenico Pangallo
- Institute of Molecular Biology, Slovak Academy of Sciences, Dúbravská cesta 21, 845 51, Bratislava, Slovakia.
| |
Collapse
|
47
|
Ahmed W, Bivins A, Metcalfe S, Smith WJM, Ziels R, Korajkic A, McMinn B, Graber TE, Simpson SL. RT-qPCR and ATOPlex sequencing for the sensitive detection of SARS-CoV-2 RNA for wastewater surveillance. WATER RESEARCH 2022; 220:118621. [PMID: 35665675 PMCID: PMC9109001 DOI: 10.1016/j.watres.2022.118621] [Citation(s) in RCA: 2] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 01/15/2022] [Revised: 05/07/2022] [Accepted: 05/13/2022] [Indexed: 05/27/2023]
Abstract
During the coronavirus disease 2019 (COVID-19) pandemic, wastewater surveillance has become an important tool for monitoring the spread of severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) within communities. In particular, reverse transcription-quantitative PCR (RT-qPCR) has been used to detect and quantify SARS-CoV-2 RNA in wastewater, while monitoring viral genome mutations requires separate approaches such as deep sequencing. A high throughput sequencing platform (ATOPlex) that uses a multiplex tiled PCR-based enrichment technique has shown promise in detecting variants of concern (VOC) while also providing virus quantitation data. However, detection sensitivities of both RT-qPCR and sequencing can be impacted through losses occurring during sample handling, virus concentration, nucleic acid extraction, and RT-qPCR. Therefore, process limit of detection (PLOD) assessments are required to estimate the gene copies of target molecule to attain specific probability of detection. In this study, we compare the PLOD of four RT-qPCR assays (US CDC N1 and N2, China CDC N and ORF1ab) for detection of SARS-CoV-2 to that of ATOPlex sequencing by seeding known concentrations of gamma-irradiated SARS-CoV-2 into wastewater. Results suggest that among the RT-qPCR assays, US CDC N1 was the most sensitive, especially at lower SARS-CoV-2 seed levels. However, when results from all RT-qPCR assays were combined, it resulted in greater detection rates than individual assays, suggesting that application of multiple assays is better suited for the trace detection of SARS-CoV-2 from wastewater samples. Furthermore, while ATOPlex offers a promising approach to SARS-CoV-2 wastewater surveillance, this approach appears to be less sensitive compared to RT-qPCR under the experimental conditions of this study, and may require further refinements. Nonetheless, the combination of RT-qPCR and ATOPlex may be a powerful tool to simultaneously detect/quantify SARS-CoV-2 RNA and monitor emerging VOC in wastewater samples.
Collapse
Affiliation(s)
- Warish Ahmed
- CSIRO Land and Water, Ecosciences Precinct, 41 Boggo Road, Dutton Park, QLD 4102, Australia.
| | - Aaron Bivins
- Department of Civil & Environmental Engineering, Louisiana State University, LA, USA
| | - Suzanne Metcalfe
- CSIRO Land and Water, Ecosciences Precinct, 41 Boggo Road, Dutton Park, QLD 4102, Australia
| | - Wendy J M Smith
- CSIRO Land and Water, Ecosciences Precinct, 41 Boggo Road, Dutton Park, QLD 4102, Australia
| | - Ryan Ziels
- Department of Civil Engineering, University of British Columbia, Vancouver, Canada
| | - Asja Korajkic
- United States Environmental Protection Agency, 26 W Martin Luther King Jr. Drive, Cincinnati, OH 45268, USA
| | - Brian McMinn
- United States Environmental Protection Agency, 26 W Martin Luther King Jr. Drive, Cincinnati, OH 45268, USA
| | - Tyson E Graber
- Children's Hospital of Eastern Ontario Research Institute, Ottawa K1H 8L1, Canada
| | | |
Collapse
|
48
|
Padilla-Reyes DA, Álvarez MM, Mora A, Cervantes-Avilés PA, Kumar M, Loge FJ, Mahlknecht J. Acquired insights from the long-term surveillance of SARS-CoV-2 RNA for COVID-19 monitoring: The case of Monterrey Metropolitan Area (Mexico). ENVIRONMENTAL RESEARCH 2022; 210:112967. [PMID: 35189100 PMCID: PMC8853965 DOI: 10.1016/j.envres.2022.112967] [Citation(s) in RCA: 9] [Impact Index Per Article: 4.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 12/12/2021] [Revised: 02/12/2022] [Accepted: 02/14/2022] [Indexed: 05/08/2023]
Abstract
Wastewater-based epidemiology offers a time- and cost-effective way to monitor SARS-CoV-2 spread in communities and therefore represents a complement to clinical testing. WBE applicability has been demonstrated in a number of cases over short-term periods as a method for tracking the prevalence of SARS-CoV-2 and an early-warning tool for predicting outbreaks in the population. This study reports SARS-CoV-2 viral loads from wastewater treatment plants (WWTPs) and hospitals over a 6-month period (June to December 2020). Results show that the overall range of viral load in positive tested samples was between 1.2 × 103 and 3.5 × 106 gene copies/l, unveiling that secondary-treated wastewaters mirrored the viral load of influents. The interpretation suggests that the viral titers found in three out of four WWTPs were associated to clinical COVID-19 surveillance indicators preceding 2-7 days the rise of reported clinical cases. The median wastewater detection rate of SARS-CoV-2 was one out of 14,300 reported new cases. Preliminary model estimates of prevalence ranged from 0.02 to 4.6% for the studied period. This comprehensive statistical and epidemiological analysis demonstrates that the applied wastewater-based approach to COVID-19 surveillance is in general consistent and feasible, although there is room for improvements.
Collapse
Affiliation(s)
- Diego A Padilla-Reyes
- Escuela de Ingeniería y Ciencias, Tecnologico de Monterrey, Campus Monterrey, Eugenio Garza Sada 2501 Sur, Monterrey, 64849, Mexico
| | - Mario Moises Álvarez
- Escuela de Ingeniería y Ciencias, Tecnologico de Monterrey, Campus Monterrey, Eugenio Garza Sada 2501 Sur, Monterrey, 64849, Mexico
| | - Abrahan Mora
- Escuela de Ingeniería y Ciencias, Tecnológico de Monterrey, Campus Puebla, Atlixcáyotl 5718, Reserva Territorial Atlixcáyotl, Puebla, 72453, Mexico
| | - Pabel A Cervantes-Avilés
- Escuela de Ingeniería y Ciencias, Tecnológico de Monterrey, Campus Puebla, Atlixcáyotl 5718, Reserva Territorial Atlixcáyotl, Puebla, 72453, Mexico
| | - Manish Kumar
- Sustainability Cluster, School of Engineering, University of Petroleum and Energy Studies (UPES), Dehradun, 248007, India
| | - Frank J Loge
- Department of Civil and Environmental Engineering, University of California Davis, One Shields Avenue, Davis, CA, 95616, USA
| | - Jürgen Mahlknecht
- Escuela de Ingeniería y Ciencias, Tecnologico de Monterrey, Campus Monterrey, Eugenio Garza Sada 2501 Sur, Monterrey, 64849, Mexico.
| |
Collapse
|
49
|
Mondelli G, Silva ER, Claro ICM, Augusto MR, Duran AFA, Cabral AD, de Moraes Bomediano Camillo L, Dos Santos Oliveira LH, de Freitas Bueno R. First case of SARS-CoV-2 RNA detection in municipal solid waste leachate from Brazil. THE SCIENCE OF THE TOTAL ENVIRONMENT 2022; 824:153927. [PMID: 35182618 PMCID: PMC9365452 DOI: 10.1016/j.scitotenv.2022.153927] [Citation(s) in RCA: 4] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 10/07/2021] [Revised: 01/17/2022] [Accepted: 02/12/2022] [Indexed: 05/12/2023]
Abstract
This work presents the first case of SARS-CoV-2 RNA detection in leachate collected from a transfer station in the city of São Paulo, Brazil. After calibration of the viral detection method already used for wastewater samples with a pilot leachate sample and virus fragments in laboratory, twelve polyethylene glycol concentrated leachates samples were tested by RT-qPCR. The results confirmed the presence of N1 gene in 9 of the 12 analyzed samples between epidemiological weeks 33 and 38 of the year 2021 (08/15/2021 to 09/19/2021). The occurrence of the N2 gene was only observed in 5 of the 12 samples. The concentration values for N1 and N2 genes varied between 3.1 and 4.6 log10.GC·L-1, which are values close to those measured in sanitary wastewater. This method showed to be a promising procedure to verify the presence of viral RNA in municipal solid waste leachate, being especially useful where there is no treatment system and sanitation infrastructure, which makes the conventional wastewater surveillance unfeasible.
Collapse
Affiliation(s)
- Giulliana Mondelli
- Center for Engineering, Modeling and Applied Social Sciences, Federal University of ABC, Santo André, São Paulo, Brazil.
| | | | - Ieda Carolina Mantovani Claro
- Center for Engineering, Modeling and Applied Social Sciences, Federal University of ABC, Santo André, São Paulo, Brazil
| | - Matheus Ribeiro Augusto
- Center for Engineering, Modeling and Applied Social Sciences, Federal University of ABC, Santo André, São Paulo, Brazil
| | - Adriana Feliciano Alves Duran
- Center for Engineering, Modeling and Applied Social Sciences, Federal University of ABC, Santo André, São Paulo, Brazil
| | - Aline Diniz Cabral
- Center for Engineering, Modeling and Applied Social Sciences, Federal University of ABC, Santo André, São Paulo, Brazil
| | | | | | - Rodrigo de Freitas Bueno
- Coordinator of the COVID-19 Monitoring Network in Wastewater National Water and Basic Sanitation Agency, Ministry of Science, Technology and Innovation and Ministry of Health, Brazil; Center for Engineering, Modeling and Applied Social Sciences, Federal University of ABC, Santo André, São Paulo, Brazil
| |
Collapse
|
50
|
Augusto MR, Claro ICM, Siqueira AK, Sousa GS, Caldereiro CR, Duran AFA, de Miranda TB, Bomediano Camillo LDM, Cabral AD, de Freitas Bueno R. Sampling strategies for wastewater surveillance: Evaluating the variability of SARS-COV-2 RNA concentration in composite and grab samples. JOURNAL OF ENVIRONMENTAL CHEMICAL ENGINEERING 2022; 10:107478. [PMID: 35251931 PMCID: PMC8882035 DOI: 10.1016/j.jece.2022.107478] [Citation(s) in RCA: 27] [Impact Index Per Article: 13.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 11/29/2021] [Revised: 01/28/2022] [Accepted: 02/25/2022] [Indexed: 05/06/2023]
Abstract
The shedding of SARS-CoV-2 RNA titers by infected individuals, even asymptomatic and oligosymptomatic ones, allows the use of wastewater monitoring to track the COVID-19 spread in a community. This approach is interesting especially for emerging countries with limited clinical testing capabilities. However, there are still important methodological aspects that need validation so that wastewater monitoring data become more representative and useful for public health. This study evaluated the between-day and within-day variability of SARS-CoV-2 RNA concentrations in 24-hour composite and grab samples from three different sampling points, including two wastewater treatment plants (WTTP) and a sewer manhole. In the between-day evaluation (17 weeks of monitoring), a good agreement between the SARS-CoV-2 RNA concentration of each sampling method was observed. There were no significant differences between the mean concentrations of the grab and composite samples (p-value > 0.05), considering N1 and N2 gene assays. The strong relationship between composite and grab samples was proven by correlation coefficients: Pearson's r of 0.83 and Spearman's rho of 0.78 (p-value < 0.05). In within-day evaluation, 24-hour cycles were analyzed and low variability in hourly viral concentrations was observed for three sampling points. The coefficient of variation (CV) values ranged from 3.0% to 11.5%. Overall, 24-hour profiles showed that viral RNA concentrations had less variability and greater agreement with the mean values between 8 a.m. and 10 a.m, the recommended time for grab sampling. Therefore, this study provides important information on wastewater sampling techniques for COVID-19 surveillance. Wastewater monitoring information will only be useful to public health and decision-makers if we ensure data quality through best practices.
Collapse
Affiliation(s)
- Matheus Ribeiro Augusto
- Federal University of ABC (UFABC), Center of Engineering, Modelling and Applied Social Sciences (CECS), Santo Andre, São Paulo 09210-580, Brazil
| | - Ieda Carolina Mantovani Claro
- Federal University of ABC (UFABC), Center of Engineering, Modelling and Applied Social Sciences (CECS), Santo Andre, São Paulo 09210-580, Brazil
| | - Aline Kaori Siqueira
- Federal University of ABC (UFABC), Center of Engineering, Modelling and Applied Social Sciences (CECS), Santo Andre, São Paulo 09210-580, Brazil
| | - Guilherme Santos Sousa
- Federal University of ABC (UFABC), Center of Engineering, Modelling and Applied Social Sciences (CECS), Santo Andre, São Paulo 09210-580, Brazil
| | - Cláudio Roberto Caldereiro
- Federal University of ABC (UFABC), Center of Engineering, Modelling and Applied Social Sciences (CECS), Santo Andre, São Paulo 09210-580, Brazil
| | - Adriana Feliciano Alves Duran
- Federal University of ABC (UFABC), Center of Engineering, Modelling and Applied Social Sciences (CECS), Santo Andre, São Paulo 09210-580, Brazil
| | - Taís Browne de Miranda
- Federal University of ABC (UFABC), Center of Engineering, Modelling and Applied Social Sciences (CECS), Santo Andre, São Paulo 09210-580, Brazil
| | - Lívia de Moraes Bomediano Camillo
- Federal University of ABC (UFABC), Center of Engineering, Modelling and Applied Social Sciences (CECS), Santo Andre, São Paulo 09210-580, Brazil
| | - Aline Diniz Cabral
- Federal University of ABC (UFABC), Center of Engineering, Modelling and Applied Social Sciences (CECS), Santo Andre, São Paulo 09210-580, Brazil
- Federal University of Uberlândia (UFU), Faculty of Veterinary Medicine, Uberlândia, Minas Gerais 38402-018, Brazil
| | - Rodrigo de Freitas Bueno
- Federal University of ABC (UFABC), Center of Engineering, Modelling and Applied Social Sciences (CECS), Santo Andre, São Paulo 09210-580, Brazil
| |
Collapse
|