1
|
He H, Huo L, Oosthuizen-Vosloo S, Pieper KJ, Stubbins A, Yoon B, Pinto AJ. Building plumbing influences the microdiversity and community assembly of the drinking water microbiome. WATER RESEARCH 2025; 276:123244. [PMID: 39933292 DOI: 10.1016/j.watres.2025.123244] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 09/23/2024] [Revised: 01/16/2025] [Accepted: 02/03/2025] [Indexed: 02/13/2025]
Abstract
Building plumbing microbial communities can significantly influence water quality at the point of use, particularly during periods of stagnation. Thus, a fine-scale understanding of factors governing community membership and structure, as well as environmental and ecological factors shaping building plumbing microbial communities is critical. In this study, we utilized full-length 16S ribosomal RNA (rRNA) gene sequencing to investigate the microdiversity and spatial-temporal dynamics of microbial communities in institutional and residential building plumbing systems. Bacterial operational taxonomic units (OTUs) within institutional buildings exhibited much lower microdiversity relative to the same OTUs in residential buildings. Higher microdiversity was associated with higher persistence and relative abundance of OTUs. Interestingly, amplicon sequencing variants within the same OTUs exhibited habitat preferences based on the building type while also demonstrating varying temporal turnover patterns. Dispersal limitation disproportionately governed community assembly in institutional buildings, whereas heterogeneous selection was the dominant ecological mechanism shaping the microbial community in residential buildings. Dispersal limitation in institutional buildings is consistent with larger building sizes and greater periods of water stagnation. Interestingly, the inability to explain the extent of heterogeneous selection-driven community assembly in residential locations using measured water chemistry may suggest a disproportionately large effect of fine-scale variation in plumbing characteristics on community assembly in residential locations.
Collapse
Affiliation(s)
- Huanqi He
- School of Civil and Environmental Engineering, Georgia Institute of Technology, Atlanta, GA 30332, USA
| | - Linxuan Huo
- School of Civil and Environmental Engineering, Georgia Institute of Technology, Atlanta, GA 30332, USA
| | - Solize Oosthuizen-Vosloo
- Institute for Cellular and Molecular Medicine, Department of Immunology, Faculty of Health Sciences, University of Pretoria, Pretoria 0084, South Africa
| | - Kelsey J Pieper
- Department of Civil and Environmental Engineering, Northeastern University, Boston, MA, USA
| | - Aron Stubbins
- Department of Civil and Environmental Engineering, Northeastern University, Boston, MA, USA
| | - Byungman Yoon
- School of Engineering and Applied Science, Harvard University, Cambridge, MA, USA
| | - Ameet J Pinto
- School of Civil and Environmental Engineering, Georgia Institute of Technology, Atlanta, GA 30332, USA; School of Earth and Atmospheric Sciences, Georgia Institute of Technology, Atlanta, GA 30332, USA.
| |
Collapse
|
2
|
Cholet F, Vignola M, Quinn D, Ijaz UZ, Sloan WT, Smith CJ. Microbial ecology of drinking water biofiltration based on 16S rRNA sequencing: A meta-analysis. WATER RESEARCH 2025; 281:123684. [PMID: 40280003 DOI: 10.1016/j.watres.2025.123684] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 12/16/2024] [Revised: 04/15/2025] [Accepted: 04/18/2025] [Indexed: 04/29/2025]
Abstract
Biofiltration, a sustainable water treatment technology relying on microbial processes to remove contaminants, offers a promising approach to achieving the United Nations Sustainable Goal 6 of universal access to clean water and sanitation by 2030. However, a key barrier to optimising biofiltration is the incomplete understanding of the biological mechanisms governing its performance. Despite numerous studies examining how engineering decisions impact biofilter performance and the associated microbiome, the significant influence of geographical location on microbial communities raises the question of whether these findings are universally applicable or location-specific. To address this, we conducted a meta-analysis of 15 biofilter microbiomes using 16S rRNA high-throughput sequencing (HTS) data, mainly originating from rapid gravity and/or granular activated carbon (GAC) filters. Despite different types and scales, results highlight geographical location as the major contributor to microbiome dissimilarity in biofilter samples (Top and Bottom) (R2∼ 0.5; p-value<0.001). The same was observed for influent waters (PERMANOVA R2= 0.76; p-value<0.001), indicating location-specific microbiomes as opposed to differences driven by different biofilter operating parameters. Irrespective of location, the higher percentage of the microbiome was assembled through deterministic processes (∼55 %) compared to stochastic processes (∼45 %). Finally, our findings suggest that the depth stratification of biofilter microbiomes may be associated with the enrichment of taxa capable of metabolising more complex organic carbon in deeper filter layers (10 enriched pathways in biofilter Bottom layers compared to 3 at the Top). These insights provide a broader understanding of biofiltration microbiomes and offer possible research avenues for targeted and effective biofilter design strategies.
Collapse
Affiliation(s)
- Fabien Cholet
- Advanced Research Centre, Infrastructure and Environment, James Watt School of Engineering, University of Glasgow, 11 Chapel Lane, Glasgow G11 6EW, United Kingdom.
| | - Marta Vignola
- Advanced Research Centre, Infrastructure and Environment, James Watt School of Engineering, University of Glasgow, 11 Chapel Lane, Glasgow G11 6EW, United Kingdom
| | - Dominic Quinn
- Advanced Research Centre, Infrastructure and Environment, James Watt School of Engineering, University of Glasgow, 11 Chapel Lane, Glasgow G11 6EW, United Kingdom
| | - Umer Z Ijaz
- Advanced Research Centre, Infrastructure and Environment, James Watt School of Engineering, University of Glasgow, 11 Chapel Lane, Glasgow G11 6EW, United Kingdom
| | - William T Sloan
- Advanced Research Centre, Infrastructure and Environment, James Watt School of Engineering, University of Glasgow, 11 Chapel Lane, Glasgow G11 6EW, United Kingdom
| | - Cindy J Smith
- Advanced Research Centre, Infrastructure and Environment, James Watt School of Engineering, University of Glasgow, 11 Chapel Lane, Glasgow G11 6EW, United Kingdom
| |
Collapse
|
3
|
Hayward C, Ross KE, Brown MH, Nisar MA, Hinds J, Jamieson T, Leterme SC, Whiley H. Handwashing basins and healthcare associated infections: Bacterial diversity in biofilms on faucets and drains. THE SCIENCE OF THE TOTAL ENVIRONMENT 2024; 949:175194. [PMID: 39094661 DOI: 10.1016/j.scitotenv.2024.175194] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 06/02/2024] [Revised: 07/12/2024] [Accepted: 07/30/2024] [Indexed: 08/04/2024]
Abstract
BACKGROUND Increasingly, hospital handwashing basins have been identified as a source of healthcare-associated infections. Biofilms formed on the faucet and drains of handbasins can potentially harbour pathogenic microbes and promote the dissemination of antimicrobial resistance. However, little is known about the diversity of these biofilm communities and the routes of contamination. AIM The aim of this paper was to use 16S rRNA gene amplicon sequencing to investigate the diversity of prokaryote communities present in faucet and drain biofilm samples taken from hospital and residential handbasins. FINDINGS The biofilm prokaryotes communities were diverse, with high abundances of potentially corrosive, biofilm forming and pathogenic genera, including those that are not typically waterborne. The β-diversity showed statistically significant differences in the variation of bacterial communities on the basis on building type (hospital vs residential p = 0.0415). However, there was no statistically significant clustering based on sampling site (faucet vs drain p = 0.46). When examining the β-diversity between individual factors, there was a significant difference between drain biofilms of different buildings (hospital drain vs residential drain p = 0.0338). CONCLUSION This study demonstrated that biofilms from hospital and residential handbasins contain complex and diverse microbial communities that differ significantly by building type. It also showed biofilms formed on the faucet and drain of a hospital's handbasins were not significantly different. Future research is needed to understand the potential mechanisms of transfer between drains and faucets of hospital handbasins. This information will inform improved infection control guidelines to control this underrecognized source of infections.
Collapse
Affiliation(s)
- Claire Hayward
- Environmental Health, College of Science and Engineering, Flinders University, Bedford Park 5042, South Australia, Australia.
| | - Kirstin E Ross
- Environmental Health, College of Science and Engineering, Flinders University, Bedford Park 5042, South Australia, Australia
| | - Melissa H Brown
- College of Science and Engineering, Flinders University, Bedford Park 5042, South Australia, Australia; Flinders Institute for NanoScale Science and Technology, College of Science and Engineering, Flinders University, Bedford Park 5042, South Australia, Australia
| | - Muhammad Atif Nisar
- Environmental Health, College of Science and Engineering, Flinders University, Bedford Park 5042, South Australia, Australia
| | - Jason Hinds
- Enware Australia Pty Ltd., 11 Endeavour Road, Caringbah 2229, New South Wales, Australia; ARC Training Centre for Biofilm Research and Innovation, Flinders University, Bedford Park 5042, South Australia, Australia
| | - Tamar Jamieson
- ARC Training Centre for Biofilm Research and Innovation, Flinders University, Bedford Park 5042, South Australia, Australia; Flinders Institute for NanoScale Science and Technology, College of Science and Engineering, Flinders University, Bedford Park 5042, South Australia, Australia
| | - Sophie C Leterme
- ARC Training Centre for Biofilm Research and Innovation, Flinders University, Bedford Park 5042, South Australia, Australia; Flinders Institute for NanoScale Science and Technology, College of Science and Engineering, Flinders University, Bedford Park 5042, South Australia, Australia
| | - Harriet Whiley
- Environmental Health, College of Science and Engineering, Flinders University, Bedford Park 5042, South Australia, Australia; Flinders Institute for NanoScale Science and Technology, College of Science and Engineering, Flinders University, Bedford Park 5042, South Australia, Australia
| |
Collapse
|
4
|
Sudarshan AS, Dai Z, Gabrielli M, Oosthuizen-Vosloo S, Konstantinidis KT, Pinto AJ. New Drinking Water Genome Catalog Identifies a Globally Distributed Bacterial Genus Adapted to Disinfected Drinking Water Systems. ENVIRONMENTAL SCIENCE & TECHNOLOGY 2024; 58:16475-16487. [PMID: 39235268 PMCID: PMC11411728 DOI: 10.1021/acs.est.4c05086] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 09/06/2024]
Abstract
Genome-resolved insights into the structure and function of the drinking water microbiome can advance the effective management of drinking water quality. To enable this, we constructed and curated thousands of metagenome-assembled and isolate genomes from drinking water distribution systems globally to develop a Drinking Water Genome Catalog (DWGC). The current DWGC disproportionately represents disinfected drinking water systems due to a paucity of metagenomes from nondisinfected systems. Using the DWGC, we identify core genera of the drinking water microbiome including a genus (UBA4765) within the order Rhizobiales that is frequently detected and highly abundant in disinfected drinking water systems. We demonstrate that this genus has been widely detected but incorrectly classified in previous amplicon sequencing-based investigations of the drinking water microbiome. Further, we show that a single genome variant (genomovar) within this genus is detected in 75% of drinking water systems included in this study. We propose a name for this uncultured bacterium as "Raskinella chloraquaticus" and describe the genus as "Raskinella" (endorsed by SeqCode). Metabolic annotation and modeling-based predictions indicate that this bacterium is capable of necrotrophic growth, is able to metabolize halogenated compounds, proliferates in a biofilm-based environment, and shows clear indications of disinfection-mediated selection.
Collapse
Affiliation(s)
- Ashwin S Sudarshan
- School of Civil and Environmental Engineering, Georgia Institute of Technology, Atlanta, Georgia 30332, United States
| | - Zihan Dai
- School of Civil and Environmental Engineering, Georgia Institute of Technology, Atlanta, Georgia 30332, United States
| | - Marco Gabrielli
- Department of Environmental Microbiology, Eawag, Swiss Federal Institute of Aquatic Science and Technology, Dubendorf CH-8600, Switzerland
| | - Solize Oosthuizen-Vosloo
- Institute for Cellular and Molecular Medicine, Department of Immunology, Faculty of Health Sciences, University of Pretoria, Pretoria 0084, South Africa
| | - Konstantinos T Konstantinidis
- School of Civil and Environmental Engineering, Georgia Institute of Technology, Atlanta, Georgia 30332, United States
| | - Ameet J Pinto
- School of Civil and Environmental Engineering, Georgia Institute of Technology, Atlanta, Georgia 30332, United States
- School of Earth and Atmospheric Sciences, Georgia Institute of Technology, Atlanta, Georgia 30332, United States
| |
Collapse
|
5
|
Taylor W, Devane ML, Russell K, Lin S, Roxburgh C, Williamson J, Gilpin BJ. Metagenomic evaluation of bacteria in drinking water using full-length 16S rRNA amplicons. JOURNAL OF WATER AND HEALTH 2024; 22:1429-1443. [PMID: 39212280 DOI: 10.2166/wh.2024.090] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 02/20/2024] [Accepted: 07/15/2024] [Indexed: 09/04/2024]
Abstract
Escherichia coli and total coliforms are important tools for identifying potential faecal contamination in drinking water. However, metagenomics offers a powerful approach for delving deeper into a bacterial community when E. coli or total coliforms are detected. Metagenomics can identify microbes native to water systems, track community changes and potential pathogens introduced by contamination events, and evaluate the effectiveness of treatment processes. Here, we demonstrate how the dual application of traditional monitoring practices and metagenomics can improve monitoring and surveillance for water resource management. The robustness of long-read metagenomics across replicates is demonstrated by the effect and interaction between manganese filters and bacterial communities, as well as the impact of chlorination after coliform detection. These examples reveal how metagenomics can identify the complex bacterial communities in the distribution system and the source waters used to supply drinking water treatment plants (DWTPs). The knowledge gained increases confidence in identified causes and mitigations of potential contamination events. By exploring bacterial communities, we can gain additional insights into the impact of faecal contamination events and treatment processes. This insight enables more precise remediation actions and enhances confidence in communicating health risks to drinking water operators and the public.
Collapse
Affiliation(s)
- William Taylor
- Environmental Science Research Institute, Christchurch, New Zealand
| | | | - Kathryn Russell
- Environmental Science Research Institute, Christchurch, New Zealand
| | - Susan Lin
- Environmental Science Research Institute, Christchurch, New Zealand
| | - Colin Roxburgh
- 3 Waters, Waimakariri District Council, Canterbury, New Zealand
| | - Judy Williamson
- 3 Waters, Christchurch City Council, Canterbury, New Zealand
| | | |
Collapse
|
6
|
Maranha A, Alarico S, Nunes-Costa D, Melo-Marques I, Roxo I, Castanheira P, Caramelo O, Empadinhas N. Drinking Water Microbiota, Entero-Mammary Pathways, and Breast Cancer: Focus on Nontuberculous Mycobacteria. Microorganisms 2024; 12:1425. [PMID: 39065193 PMCID: PMC11279143 DOI: 10.3390/microorganisms12071425] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/29/2024] [Revised: 07/03/2024] [Accepted: 07/09/2024] [Indexed: 07/28/2024] Open
Abstract
The prospect of drinking water serving as a conduit for gut bacteria, artificially selected by disinfection strategies and a lack of monitoring at the point of use, is concerning. Certain opportunistic pathogens, notably some nontuberculous mycobacteria (NTM), often exceed coliform bacteria levels in drinking water, posing safety risks. NTM and other microbiota resist chlorination and thrive in plumbing systems. When inhaled, opportunistic NTM can infect the lungs of immunocompromised or chronically ill patients and the elderly, primarily postmenopausal women. When ingested with drinking water, NTM often survive stomach acidity, reach the intestines, and migrate to other organs using immune cells as vehicles, potentially colonizing tumor tissue, including in breast cancer. The link between the microbiome and cancer is not new, yet the recognition of intratumoral microbiomes is a recent development. Breast cancer risk rises with age, and NTM infections have emerged as a concern among breast cancer patients. In addition to studies hinting at a potential association between chronic NTM infections and lung cancer, NTM have also been detected in breast tumors at levels higher than normal adjacent tissue. Evaluating the risks of continued ingestion of contaminated drinking water is paramount, especially given the ability of various bacteria to migrate from the gut to breast tissue via entero-mammary pathways. This underscores a pressing need to revise water safety monitoring guidelines and delve into hormonal factors, including addressing the disproportionate impact of NTM infections and breast cancer on women and examining the potential health risks posed by the cryptic and unchecked microbiota from drinking water.
Collapse
Affiliation(s)
- Ana Maranha
- Center for Neuroscience and Cell Biology (CNC-UC), University of Coimbra, 3004-504 Coimbra, Portugal; (A.M.); (S.A.); (D.N.-C.); (I.M.-M.); (I.R.)
- Centre for Innovative Biomedicine & Biotechnology (CIBB), University of Coimbra, 3004-504 Coimbra, Portugal
| | - Susana Alarico
- Center for Neuroscience and Cell Biology (CNC-UC), University of Coimbra, 3004-504 Coimbra, Portugal; (A.M.); (S.A.); (D.N.-C.); (I.M.-M.); (I.R.)
- Centre for Innovative Biomedicine & Biotechnology (CIBB), University of Coimbra, 3004-504 Coimbra, Portugal
| | - Daniela Nunes-Costa
- Center for Neuroscience and Cell Biology (CNC-UC), University of Coimbra, 3004-504 Coimbra, Portugal; (A.M.); (S.A.); (D.N.-C.); (I.M.-M.); (I.R.)
- Centre for Innovative Biomedicine & Biotechnology (CIBB), University of Coimbra, 3004-504 Coimbra, Portugal
| | - Inês Melo-Marques
- Center for Neuroscience and Cell Biology (CNC-UC), University of Coimbra, 3004-504 Coimbra, Portugal; (A.M.); (S.A.); (D.N.-C.); (I.M.-M.); (I.R.)
- Centre for Innovative Biomedicine & Biotechnology (CIBB), University of Coimbra, 3004-504 Coimbra, Portugal
| | - Inês Roxo
- Center for Neuroscience and Cell Biology (CNC-UC), University of Coimbra, 3004-504 Coimbra, Portugal; (A.M.); (S.A.); (D.N.-C.); (I.M.-M.); (I.R.)
- Centre for Innovative Biomedicine & Biotechnology (CIBB), University of Coimbra, 3004-504 Coimbra, Portugal
- Ph.D. Programme in Biomedicine and Experimental Biology (PDBEB), Institute for Interdisciplinary Research, University of Coimbra, 3004-504 Coimbra, Portugal
| | | | - Olga Caramelo
- Gynecology Department, Coimbra Hospital and University Centre (CHUC), 3004-561 Coimbra, Portugal;
| | - Nuno Empadinhas
- Center for Neuroscience and Cell Biology (CNC-UC), University of Coimbra, 3004-504 Coimbra, Portugal; (A.M.); (S.A.); (D.N.-C.); (I.M.-M.); (I.R.)
- Centre for Innovative Biomedicine & Biotechnology (CIBB), University of Coimbra, 3004-504 Coimbra, Portugal
| |
Collapse
|
7
|
Dowdell KS, Olsen K, Martinez Paz EF, Sun A, Keown J, Lahr R, Steglitz B, Busch A, LiPuma JJ, Olson T, Raskin L. Investigating the suitability of online flow cytometry for monitoring full-scale drinking water ozone system disinfection effectiveness. WATER RESEARCH 2024; 257:121702. [PMID: 38749337 DOI: 10.1016/j.watres.2024.121702] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 12/28/2023] [Revised: 04/02/2024] [Accepted: 04/29/2024] [Indexed: 05/29/2024]
Abstract
While online monitoring of physicochemical parameters has widely been incorporated into drinking water treatment systems, online microbial monitoring has lagged behind, resulting in the use of surrogate parameters (disinfectant residual, applied dose, concentration × time, CT) to assess disinfection system performance. Online flow cytometry (online FCM) allows for automated quantification of total and intact microbial cells. This study sought to investigate the feasibility of online FCM for full-scale drinking water ozone disinfection system performance monitoring. A water treatment plant with high lime solids turbidity in the ozone contactor influent was selected to evaluate the online FCM in challenging conditions. Total and intact cell counts were monitored for 40 days and compared to surrogate parameters (ozone residual, ozone dose, and CT) and grab sample assay results for cellular adenosine triphosphate (cATP), heterotrophic plate counts (HPC), impedance flow cytometry, and 16S rRNA gene sequencing. Online FCM provided insight into the dynamics of the full-scale ozone system, including offering early warning of increased contactor effluent cell concentrations, which was not observed using surrogate measures. Positive correlations were observed between online FCM intact cell counts and cATP levels (Kendall's tau=0.40), HPC (Kendall's tau=0.20), and impedance flow cytometry results (Kendall's tau=0.30). Though a strong correlation between log intact cell removal and CT was not observed, 16S rRNA gene sequencing results showed that passage through the ozone contactor significantly changed the microbial community (p < 0.05). Potential causes of the low overall cell inactivation in the contactor and the significant changes in the microbial community after ozonation include regrowth in the later chambers of the contactor and varied ozone resistance of drinking water microorganisms. This study demonstrates the suitability of direct, online microbial analysis for monitoring full-scale disinfection systems.
Collapse
Affiliation(s)
- Katherine S Dowdell
- Department of Civil and Environmental Engineering, University of Michigan, 1353 Beal Ave., Ann Arbor, MI 48109, USA
| | - Kirk Olsen
- Department of Civil and Environmental Engineering, University of Michigan, 1353 Beal Ave., Ann Arbor, MI 48109, USA
| | - Ernesto F Martinez Paz
- Department of Civil and Environmental Engineering, University of Michigan, 1353 Beal Ave., Ann Arbor, MI 48109, USA
| | - Aini Sun
- Department of Civil and Environmental Engineering, University of Michigan, 1353 Beal Ave., Ann Arbor, MI 48109, USA
| | - Jeff Keown
- Ann Arbor Water Treatment Plant, City of Ann Arbor, 919 Sunset Rd., Ann Arbor, MI 48103, USA
| | - Rebecca Lahr
- Ann Arbor Water Treatment Plant, City of Ann Arbor, 919 Sunset Rd., Ann Arbor, MI 48103, USA
| | - Brian Steglitz
- Ann Arbor Water Treatment Plant, City of Ann Arbor, 919 Sunset Rd., Ann Arbor, MI 48103, USA
| | - Andrea Busch
- Great Lakes Water Authority, 9300W. Jefferson Ave, Detroit, MI 48209, USA
| | - John J LiPuma
- Department of Pediatrics, University of Michigan Medical School, 8323 MSRB III, SPC5646, 1150W. Med Cntr Dr., Ann Arbor, MI 48109, USA
| | - Terese Olson
- Department of Civil and Environmental Engineering, University of Michigan, 1353 Beal Ave., Ann Arbor, MI 48109, USA
| | - Lutgarde Raskin
- Department of Civil and Environmental Engineering, University of Michigan, 1353 Beal Ave., Ann Arbor, MI 48109, USA.
| |
Collapse
|
8
|
Waegenaar F, García-Timermans C, Van Landuyt J, De Gusseme B, Boon N. Impact of operational conditions on drinking water biofilm dynamics and coliform invasion potential. Appl Environ Microbiol 2024; 90:e0004224. [PMID: 38647288 PMCID: PMC11107155 DOI: 10.1128/aem.00042-24] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/17/2024] [Accepted: 03/27/2024] [Indexed: 04/25/2024] Open
Abstract
Biofilms within drinking water distribution systems serve as a habitat for drinking water microorganisms. However, biofilms can negatively impact drinking water quality by causing water discoloration and deterioration and can be a reservoir for unwanted microorganisms. In this study, we investigated whether indicator organisms for drinking water quality, such as coliforms, can settle in mature drinking water biofilms. Therefore, a biofilm monitor consisting of glass rings was used to grow and sample drinking water biofilms. Two mature drinking water biofilms were characterized by flow cytometry, ATP measurements, confocal laser scanning microscopy, and 16S rRNA sequencing. Biofilms developed under treated chlorinated surface water supply exhibited lower cell densities in comparison with biofilms resulting from treated groundwater. Overall, the phenotypic as well as the genotypic characteristics were significantly different between both biofilms. In addition, the response of the biofilm microbiome and possible biofilm detachment after minor water quality changes were investigated. Limited changes in pH and free chlorine addition, to simulate operational changes that are relevant for practice, were evaluated. It was shown that both biofilms remained resilient. Finally, mature biofilms were prone to invasion of the coliform, Serratia fonticola. After spiking low concentrations (i.e., ±100 cells/100 mL) of the coliform to the corresponding bulk water samples, the coliforms were able to attach and get established within the mature biofilms. These outcomes emphasize the need for continued research on biofilm detachment and its implications for water contamination in distribution networks. IMPORTANCE The revelation that even low concentrations of coliforms can infiltrate into mature drinking water biofilms highlights a potential public health concern. Nowadays, the measurement of coliform bacteria is used as an indicator for fecal contamination and to control the effectiveness of disinfection processes and the cleanliness and integrity of distribution systems. In Flanders (Belgium), 533 out of 18,840 measurements exceeded the established norm for the coliform indicator parameter in 2021; however, the source of microbial contamination is mostly unknown. Here, we showed that mature biofilms, are susceptible to invasion of Serratia fonticola. These findings emphasize the importance of understanding and managing biofilms in drinking water distribution systems, not only for their potential to influence water quality, but also for their role in harboring and potentially disseminating pathogens. Further research into biofilm detachment, long-term responses to operational changes, and pathogen persistence within biofilms is crucial to inform strategies for safeguarding drinking water quality.
Collapse
Affiliation(s)
- Fien Waegenaar
- Department of Biotechnology, Center for Microbial Ecology and Technology (CMET), Ghent University, Ghent, Belgium
- Center for Advanced Process Technology for Urban Resource Recovery (CAPTURE), Ghent, Belgium
| | - Cristina García-Timermans
- Department of Biotechnology, Center for Microbial Ecology and Technology (CMET), Ghent University, Ghent, Belgium
- Center for Advanced Process Technology for Urban Resource Recovery (CAPTURE), Ghent, Belgium
| | - Josefien Van Landuyt
- Department of Biotechnology, Center for Microbial Ecology and Technology (CMET), Ghent University, Ghent, Belgium
- Center for Advanced Process Technology for Urban Resource Recovery (CAPTURE), Ghent, Belgium
| | - Bart De Gusseme
- Department of Biotechnology, Center for Microbial Ecology and Technology (CMET), Ghent University, Ghent, Belgium
- Center for Advanced Process Technology for Urban Resource Recovery (CAPTURE), Ghent, Belgium
- Farys, Department R&D – Innovation Water, Ghent, Belgium
| | - Nico Boon
- Department of Biotechnology, Center for Microbial Ecology and Technology (CMET), Ghent University, Ghent, Belgium
- Center for Advanced Process Technology for Urban Resource Recovery (CAPTURE), Ghent, Belgium
| |
Collapse
|
9
|
Wei Y, Wu H, Zhang X, Liang Y, Shi D, Wang L, Li H, Yu H, Yang D, Zhou S, Chen T, Yang Z, Li J, Jin M. Comparative analysis of chlorine-resistant bacteria after chlorination and chloramination in drinking water treatment plants. JOURNAL OF HAZARDOUS MATERIALS 2024; 469:134075. [PMID: 38508114 DOI: 10.1016/j.jhazmat.2024.134075] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 08/13/2023] [Revised: 02/04/2024] [Accepted: 03/17/2024] [Indexed: 03/22/2024]
Abstract
Chlorine-resistant bacteria (CRB) in drinking water treatment plants (DWTPs) jeopardize water quality and pose a potential risk to human health. However, the specific response of CRB to chlorination and chloramination remains uncharacterized. Therefore, we analyzed 16 S rRNA sequencing data from water samples before and after chlorination and chloramination taken between January and December 2020. Proteobacteria and Firmicutes dominated all finished water samples. After chloramination, Acinetobacter, Pseudomonas, Methylobacterium, Ralstonia, and Sphingomonas were the dominant CRB, whereas Ralstonia, Bacillus, Acinetobacter, Pseudomonas, and Enterococcus were prevalent after chlorination. Over 75% of the CRB e.g. Acinetobacter, Pseudomonas, Bacillus, and Enterococcus were shared between the chlorination and chloramination, involving potentially pathogens, such as Acinetobacter baumannii and Pseudomonas aeruginosa. Notably, certain genera such as Faecalibacterium, Geobacter, and Megasphaera were enriched as strong CRB after chloramination, whereas Vogesella, Flavobacterium, Thalassolituus, Pseudoalteromonas, and others were enriched after chlorination according to LEfSe analysis. The shared CRB correlated with temperature, pH, and turbidity, displaying a seasonal pattern with varying sensitivity to chlorination and chloramination in cold and warm seasons. These findings enhance our knowledge of the drinking water microbiome and microbial health risks, thus enabling better infectious disease control through enhanced disinfection strategies in DWTPs.
Collapse
Affiliation(s)
- Yijun Wei
- Department of Environment and Health, Tianjin Institute of Environmental & Operational Medicine, Key Laboratory of Risk Assessment and Control for Environment & Food Safety, Tianjin 300050, China
| | - Haiyan Wu
- Department of Environment and Health, Tianjin Institute of Environmental & Operational Medicine, Key Laboratory of Risk Assessment and Control for Environment & Food Safety, Tianjin 300050, China
| | - Xudong Zhang
- Water Quality Monitoring Center of Tianjin Water Group Co. Ltd, Tianjin 300240, China
| | - Yongbing Liang
- Department of Environment and Health, Tianjin Institute of Environmental & Operational Medicine, Key Laboratory of Risk Assessment and Control for Environment & Food Safety, Tianjin 300050, China
| | - Danyang Shi
- Department of Environment and Health, Tianjin Institute of Environmental & Operational Medicine, Key Laboratory of Risk Assessment and Control for Environment & Food Safety, Tianjin 300050, China
| | - Lin Wang
- Water Quality Monitoring Center of Tianjin Water Group Co. Ltd, Tianjin 300240, China
| | - Haibei Li
- Department of Environment and Health, Tianjin Institute of Environmental & Operational Medicine, Key Laboratory of Risk Assessment and Control for Environment & Food Safety, Tianjin 300050, China
| | - Hongling Yu
- Water Quality Monitoring Center of Tianjin Water Group Co. Ltd, Tianjin 300240, China
| | - Dong Yang
- Department of Environment and Health, Tianjin Institute of Environmental & Operational Medicine, Key Laboratory of Risk Assessment and Control for Environment & Food Safety, Tianjin 300050, China
| | - Shuqing Zhou
- Department of Environment and Health, Tianjin Institute of Environmental & Operational Medicine, Key Laboratory of Risk Assessment and Control for Environment & Food Safety, Tianjin 300050, China
| | - Tianjiao Chen
- Department of Environment and Health, Tianjin Institute of Environmental & Operational Medicine, Key Laboratory of Risk Assessment and Control for Environment & Food Safety, Tianjin 300050, China
| | - Zhongwei Yang
- Department of Environment and Health, Tianjin Institute of Environmental & Operational Medicine, Key Laboratory of Risk Assessment and Control for Environment & Food Safety, Tianjin 300050, China
| | - Junwen Li
- Department of Environment and Health, Tianjin Institute of Environmental & Operational Medicine, Key Laboratory of Risk Assessment and Control for Environment & Food Safety, Tianjin 300050, China
| | - Min Jin
- Department of Environment and Health, Tianjin Institute of Environmental & Operational Medicine, Key Laboratory of Risk Assessment and Control for Environment & Food Safety, Tianjin 300050, China.
| |
Collapse
|
10
|
Kalu CM, Mudau KL, Masindi V, Ijoma GN, Tekere M. Occurrences and implications of pathogenic and antibiotic-resistant bacteria in different stages of drinking water treatment plants and distribution systems. Heliyon 2024; 10:e26380. [PMID: 38434035 PMCID: PMC10906316 DOI: 10.1016/j.heliyon.2024.e26380] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/01/2023] [Revised: 12/05/2023] [Accepted: 02/12/2024] [Indexed: 03/05/2024] Open
Abstract
Different stages of drinking water treatment plants (DWTPs) play specific roles in diverse contaminants' removal present in natural water sources. Although the stages are recorded to promote adequate treatment of water, the occurrence of pathogenic bacteria (PB) and antibiotic-resistant bacteria (ARB) in the treated water and the changes in their diversity and abundance as it passed down to the end users through the drinking water distribution systems (DWDSs), is a great concern, especially to human health. This could imply that the different stages and the distribution system provide a good microenvironment for their growth. Hence, it becomes pertinent to constantly monitor and document the diversity of PB and ARB present at each stage of the treatment and distribution system. This review aimed at documenting the occurrence of PB and ARB at different stages of treatment and distribution systems as well as the implication of their occurrence globally. An exhaustive literature search from Web of Science, Science-Direct database, Google Scholar, Academic Research Databases like the National Center for Biotechnology Information, Scopus, and SpringerLink was done. The obtained information showed that the different treatment stages and distribution systems influence the PB and ARB that proliferate. To minimize the human health risks associated with the occurrence of these PB, the present review, suggests the development of advanced technologies that can promote quick monitoring of PB/ARB at each treatment stage and distribution system as well as reduction of the cost of environomics analysis to promote better microbial analysis.
Collapse
Affiliation(s)
- Chimdi M. Kalu
- Department of Environmental Science, College of Agriculture and Environmental Sciences, University of South Africa, Florida, 1710, South Africa
| | - Khuthadzo L. Mudau
- Department of Environmental Science, College of Agriculture and Environmental Sciences, University of South Africa, Florida, 1710, South Africa
| | - Vhahangwele Masindi
- Department of Environmental Science, College of Agriculture and Environmental Sciences, University of South Africa, Florida, 1710, South Africa
- Magalies Water, Scientific Services, Research & Development Division, Brits, South Africa
| | - Grace N. Ijoma
- Department of Environmental Science, College of Agriculture and Environmental Sciences, University of South Africa, Florida, 1710, South Africa
| | - Memory Tekere
- Department of Environmental Science, College of Agriculture and Environmental Sciences, University of South Africa, Florida, 1710, South Africa
| |
Collapse
|
11
|
Hawer H, Burmester R, Sonnenberg N, Weiß K. Detection of endotoxins from selected drinking water microbiota using an LAL-based assay and its implications for human health. JOURNAL OF WATER AND HEALTH 2024; 22:290-295. [PMID: 38421623 PMCID: wh_2024_207 DOI: 10.2166/wh.2024.207] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 03/02/2024]
Abstract
Endotoxins are pyrogenic lipopolysaccharides from Gram-negative bacteria that are known to induce fever, septic shock, and multiple organ failure, posing a substantial risk to human health. Drinking water systems are especially prone to home microbiomes containing a large variety of Gram-negative bacteria. Consumption of water from these systems in developed countries is generally regarded as non-hazardous to humans due to the low number of non-pathogenic bacterial cells per milliliter and oral admission. To assess potential risks posed by endotoxins in drinking water systems, we conducted a conventional microbiological investigation on a local community water system in the north of Germany and mined the resulting data to investigate the endotoxin contents of some of the most abundant microbiota found during these analyses. Using a Limulus amoebocyte lysate (LAL) -based endotoxin detection method, average normalized endotoxin content was determined. Although the average culturable amounts of microbiota in the drinking water system were insufficient to exert endotoxin levels critical to human health, peaks and acute contaminations may pose substantial health risks.
Collapse
Affiliation(s)
- Harmen Hawer
- Panpharma GmbH, Bunsenstraße 4, 22946, Trittau, Germany E-mail:
| | | | | | - Katja Weiß
- Panpharma GmbH, Bunsenstraße 4, 22946, Trittau, Germany
| |
Collapse
|
12
|
Kamal MA, Alhotan RA, Al Sulaiman AR, Hussein EO, Galik B, Saleh AA. From source to house: unraveling the seasonal effect of water distribution system on drinking water quality of poultry farms under Egyptian environmental condition. ENVIRONMENTAL SCIENCE AND POLLUTION RESEARCH INTERNATIONAL 2024; 31:12966-12977. [PMID: 38236566 DOI: 10.1007/s11356-024-31911-3] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 09/19/2023] [Accepted: 01/03/2024] [Indexed: 01/19/2024]
Abstract
Improvements in drinking water quality (DWQ) can lead, according to some estimates, to a 10% reduction of the world's disease load. The drinking water distribution system (DWDS) plays a crucial role in influencing DWQ and can contribute to the emergence of poultry-related epidemics. This study aims to monitor the variations in DWQ throughout the seasons within the DWDS of Egyptian poultry farms experiencing epidemics. The study assessed DWQ at four different points along the DWDS, including the water source (WS), water tank (WT), broiler drinker (BD), and layer drinker (LD), across 86 farms. Statistical analysis was employed to establish correlations between DWQ and the sampling points within the DWDS, as well as between water temperature (Tw.C°), ambient temperature (Ta.C°), and microbial DWQ. The survey revealed significant differences between Tw.C° and Ta.C°, with notable effect sizes (d = 0.89-1). Additionally, the results revealed significant differences in physicochemical DWQ between WS and house drinkers (HD), with medium to large effect sizes (d = 0.56-0.85). Furthermore, significant differences were identified in microbial DWQ between winter and summer, with a small to large effect size (d = 0.40-0.87). Notably, we recorded significant differences in microbial DWQ between WS and WT, with a small to medium effect size (d = 0.40-0.61), and between WT and BD, with a small to medium effect size (d = 0.48-0.53). Additionally, we found significant differences in microbial DWQ between WS and LD, with a medium effect size (d = 0.59-0.68). In conclusion, Tw.C° is influenced by seasonal variations in Ta.C°. While the physicochemical DWQ was unaffected by seasonal temperature variations, it was significantly impacted by the DWDS from WS to HD. In contrast, the microbial DWQ was strongly influenced by both seasonal temperature changes and DWDS.
Collapse
Affiliation(s)
- Mohammed Abdelhameed Kamal
- Department of Veterinary Hygiene and Management, Faculty of Veterinary Medicine, Cairo University, Giza, 11221, Egypt
| | - Rashed A Alhotan
- Department of Animal Production, College of Food & Agriculture Sciences, King Saud University, P. O. Box 2460, 11451, Riyadh, Saudi Arabia
| | - Ali R Al Sulaiman
- Department of Animal Production, College of Food & Agriculture Sciences, King Saud University, P. O. Box 2460, 11451, Riyadh, Saudi Arabia
| | - Elsayed Osman Hussein
- AlKhumasia for Feed and Animal, Products Riyadh - Olaya - Al Aqareyah 2 - Office 705, PO 8344, 11982, Riyadh, Saudi Arabia
| | - Branislav Galik
- Institute of Nutrition and Genomics, Slovak University of Agriculture in Nitra, Trieda A. Hlinku 2, 94976, Nitra, Slovakia
| | - Ahmed Ali Saleh
- Department of Poultry Production, Faculty of Agriculture, Kafrelsheikh University, Kafr El-Sheikh, 333516, Egypt.
| |
Collapse
|
13
|
Ke Y, Sun W, Xue Y, Zhu Y, Yan S, Xie S. Effects of treatments and distribution on microbiome and antibiotic resistome from source to tap water in three Chinese geographical regions based on metagenome assembly. WATER RESEARCH 2024; 249:120894. [PMID: 38016224 DOI: 10.1016/j.watres.2023.120894] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 04/28/2023] [Revised: 10/23/2023] [Accepted: 11/17/2023] [Indexed: 11/30/2023]
Abstract
Antibiotic resistance genes (ARGs) represent emerging environmental pollutants that present health risks. Drinking water supply systems (DWSSs), including sources to tap water, play crucial roles in the dissemination and propagation of ARGs. However, there was a paucity of knowledge on the relative abundance, diversity, mobility, and pathogenic hosts of ARGs in DWSSs from source to tap. Therefore, the effects of treatments and distributions on the microbial community and ARGs from three geographical regions (downstream areas of the Yellow, Yangtze, and Pearl Rivers) were elucidated in the present study. Treatment processes lowered the complexity of the microbial community network, whereas transportation increased it. The assembly mechanisms of the microbial community and antibiotic resistome were primarily driven by stochastic processes. Distribution greatly increased the contribution of stochastic processes. Multidrug ARGs (for example, multidrug transporter and adeJ) and bacitracin ARG (bacA) were the primary mobile ARGs in drinking water, as identified by the metagenomic assembly. Achromobacter xylosoxidans, Acinetobacter calcoaceticus, and Acinetobacter junii harbored diverse multidrug ARGs and mobile genetic elements (MGEs) (recombinases, integrases, and transposases) as potential pathogens and were abundant in the disinfected water. Environmental factors, including pH, chlorine, latitude, longitude, and temperature, influenced the ARG abundance by directly regulating the MGEs and microbial community diversity. This study provides critical information on the fate, mobility, host pathogenicity, and driving factors of ARGs in drinking water, which is conducive to ARG risk assessment and management to provide high-quality drinking water to consumers.
Collapse
Affiliation(s)
- Yanchu Ke
- School of Environment, Tsinghua University, Beijing 100084, China; State Key Joint Laboratory of Environmental Simulation and Pollution Control, College of Environmental Sciences and Engineering, Peking University, Beijing 100871, China
| | - Wenjun Sun
- School of Environment, Tsinghua University, Beijing 100084, China; Research Institute for Environmental Innovation (Suzhou) Tsinghua, Suzhou 215163, China.
| | - Yanei Xue
- School of Environment, Tsinghua University, Beijing 100084, China
| | - Ying Zhu
- State Key Joint Laboratory of Environmental Simulation and Pollution Control, College of Environmental Sciences and Engineering, Peking University, Beijing 100871, China
| | - Shuang Yan
- State Key Joint Laboratory of Environmental Simulation and Pollution Control, College of Environmental Sciences and Engineering, Peking University, Beijing 100871, China
| | - Shuguang Xie
- State Key Joint Laboratory of Environmental Simulation and Pollution Control, College of Environmental Sciences and Engineering, Peking University, Beijing 100871, China.
| |
Collapse
|
14
|
Yang J, Hu Y, Zhang Y, Zhou S, Meng D, Xia S, Wang H. Deciphering the diversity and assemblage mechanisms of nontuberculous mycobacteria community in four drinking water distribution systems with different disinfectants. THE SCIENCE OF THE TOTAL ENVIRONMENT 2024; 907:168176. [PMID: 37907107 DOI: 10.1016/j.scitotenv.2023.168176] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 09/04/2023] [Revised: 10/25/2023] [Accepted: 10/26/2023] [Indexed: 11/02/2023]
Abstract
Nontuberculous mycobacteria (NTM) represent an emerging health concern due to their escalating infections worldwide. Although drinking water distribution systems (DWDSs) have been considered as NTM reservoirs and a potential infection route, NTM community at the species level remain largely elusive in DWDSs. This study employed high-throughput sequencing coupled with qPCR to profile NTM community and estimate their abundances at the species level in water and biofilm samples in four DWDSs using three different disinfectants (i.e. free chlorine, chloramine and chlorine dioxide). Results demonstrated the dominance of Mycobacterium paragordonae and Mycobacterium mucogenicum in both biofilm and water across four DWDSs, whereas Mycobacterium abscessus and Mycobacterium chelonae, the two clinically significant species, exhibited low abundance but high prevalence. Comparable NTM community was observed in biofilm across these four DWDSs. Distinct separation of NTM community between SH-chloramine DWDSs water and other DWDSs highlighted the selective pressure of chloramine on NTM community. Furthermore, the research revealed that biofilm and water exhibited distinct NTM community structures, with biofilm harboring more diverse NTM community. Certain NTM species displayed a preference for biofilm, such as Mycobacterium gordonae, while others, like Mycobacterium mucogenicum, were more abundant in water samples (P < 0.05). In terms of NTM community assembly, stochastic processes dominated biofilm, while comparable role of stochastic and deterministic processes was observed in water. In conclusion, this study offers a pioneering and comprehensive insight into the dynamics and assembly mechanisms of NTM community within four DWDSs treated with three distinct disinfectants. These findings serve as a critical foundation for assessing NTM exposure risks and devising effective management strategies within DWDSs.
Collapse
Affiliation(s)
- Jinhao Yang
- State Key Laboratory of Pollution Control and Resources Reuse, College of Environmental Science and Engineering, Tongji University, Shanghai 200092, China; Shanghai Institute of Pollution Control and Ecological Security, Shanghai 200092, China
| | - Yuxing Hu
- State Key Laboratory of Pollution Control and Resources Reuse, College of Environmental Science and Engineering, Tongji University, Shanghai 200092, China; Shanghai Institute of Pollution Control and Ecological Security, Shanghai 200092, China
| | - Yue Zhang
- State Key Laboratory of Pollution Control and Resources Reuse, College of Environmental Science and Engineering, Tongji University, Shanghai 200092, China; Shanghai Institute of Pollution Control and Ecological Security, Shanghai 200092, China
| | - Shuang Zhou
- School of Medicine, Tongji University, Shanghai 200092, China
| | - Die Meng
- Shanghai Pulmonary Hospital, Tongji University, Shanghai 200433, China
| | - Siqing Xia
- State Key Laboratory of Pollution Control and Resources Reuse, College of Environmental Science and Engineering, Tongji University, Shanghai 200092, China
| | - Hong Wang
- State Key Laboratory of Pollution Control and Resources Reuse, College of Environmental Science and Engineering, Tongji University, Shanghai 200092, China; Shanghai Institute of Pollution Control and Ecological Security, Shanghai 200092, China.
| |
Collapse
|
15
|
Yuan W, She J, Liu J, Zhang Q, Wei X, Huang L, Zeng X, Wang J. Insight into microbial functional genes' role in geochemical distribution and cycling of uranium: The evidence from covering soils of uranium tailings dam. JOURNAL OF HAZARDOUS MATERIALS 2024; 461:132630. [PMID: 37774604 DOI: 10.1016/j.jhazmat.2023.132630] [Citation(s) in RCA: 7] [Impact Index Per Article: 7.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 07/31/2023] [Revised: 08/26/2023] [Accepted: 09/23/2023] [Indexed: 10/01/2023]
Abstract
There exists a research gap on microbial functional genes' role in U geochemical behavior and cycling in U contaminated soils, which has been poorly understood. Herein, 16S rRNA sequencing gene amplifiers and metagenome analysis were applied to probe microbial community structure and functional metabolism of different depth layers of covering soils in U tailings dam. Results showed that the soils were highly enriched with U (47.5-123.3 mg/kg) and a remarkable portion of 35-70% was associated with the labile fractions. It was found that U geochemical distribution was notably interacted with functional genes from N, S, Fe and P related microbes. Importantly, diminution in gene NirK and amplification in nrfH involving in nitrate reduction could induce microbial tolerance to U. Moreover, gene Sat in microbial sulfate reduction, NosZ and NorB in nitrate reduction, phnD, upgA and upgC in P transportation and phnI, phnK, phoA and opd in microbial organic P mineralization, were all closely linked to U geochemical distribution, species and cycling. All these findings disclose the functional genes that may control the transfer and transformation behavior of U in soil environment, which provides important and novel indications for the bio-remediation strategies towards U polluted sites.
Collapse
Affiliation(s)
- Wenhuan Yuan
- Guangdong Provincial Key Laboratory of Radionuclides Pollution Control and Resources, School of Environmental Science and Engineering, Guangzhou University, Guangzhou, China
| | - Jingye She
- Guangdong Provincial Key Laboratory of Radionuclides Pollution Control and Resources, School of Environmental Science and Engineering, Guangzhou University, Guangzhou, China
| | - Juan Liu
- Guangdong Provincial Key Laboratory of Radionuclides Pollution Control and Resources, School of Environmental Science and Engineering, Guangzhou University, Guangzhou, China
| | - Qiong Zhang
- Department of Ocean Science, The Hong Kong University of Science and Technology, Hong Kong, China
| | - Xudong Wei
- Guangdong Provincial Key Laboratory of Radionuclides Pollution Control and Resources, School of Environmental Science and Engineering, Guangzhou University, Guangzhou, China
| | - Liting Huang
- Guangdong Provincial Key Laboratory of Radionuclides Pollution Control and Resources, School of Environmental Science and Engineering, Guangzhou University, Guangzhou, China
| | - Xuan Zeng
- Guangdong Provincial Key Laboratory of Radionuclides Pollution Control and Resources, School of Environmental Science and Engineering, Guangzhou University, Guangzhou, China
| | - Jin Wang
- Guangdong Provincial Key Laboratory of Radionuclides Pollution Control and Resources, School of Environmental Science and Engineering, Guangzhou University, Guangzhou, China.
| |
Collapse
|
16
|
Spencer-Williams I, Meyer M, DePas W, Elliott E, Haig SJ. Assessing the Impacts of Lead Corrosion Control on the Microbial Ecology and Abundance of Drinking-Water-Associated Pathogens in a Full-Scale Drinking Water Distribution System. ENVIRONMENTAL SCIENCE & TECHNOLOGY 2023; 57:20360-20369. [PMID: 37970641 DOI: 10.1021/acs.est.3c05272] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/17/2023]
Abstract
Increases in phosphate availability in drinking water distribution systems (DWDSs) from the use of phosphate-based corrosion control strategies may result in nutrient and microbial community composition shifts in the DWDS. This study assessed the year-long impacts of full-scale DWDS orthophosphate addition on both the microbial ecology and density of drinking-water-associated pathogens that infect the immunocompromised (DWPIs). Using 16S rRNA gene amplicon sequencing and droplet digital PCR, drinking water microbial community composition and DWPI density were examined. Microbial community composition analysis suggested significant compositional changes after the orthophosphate addition. Significant increases in total bacterial density were observed after orthophosphate addition, likely driven by a 2 log 10 increase in nontuberculous mycobacteria (NTM). Linear effect models confirmed the importance of phosphate addition with phosphorus concentration explaining 17% and 12% of the variance in NTM and L. pneumophila density, respectively. To elucidate the impact of phosphate on NTM aggregation, a comparison of planktonic and aggregate fractions of NTM cultures grown at varying phosphate concentrations was conducted. Aggregation assay results suggested that higher phosphate concentrations cause more disaggregation, and the interaction between phosphate and NTM is species specific. This work reveals new insight into the consequences of orthophosphate application on the DWDS microbiome and highlights the importance of proactively monitoring the DWDS for DWPIs.
Collapse
Affiliation(s)
- Isaiah Spencer-Williams
- Department of Civil and Environmental Engineering, University of Pittsburgh, Pittsburgh, Pennsylvania 15261, United States
| | - Mitchell Meyer
- Department of Pediatrics, University of Pittsburgh School of Medicine, Pittsburgh, Pennsylvania 15261, United States
| | - William DePas
- Department of Pediatrics, University of Pittsburgh School of Medicine, Pittsburgh, Pennsylvania 15261, United States
| | - Emily Elliott
- Department of Civil and Environmental Engineering, University of Pittsburgh, Pittsburgh, Pennsylvania 15261, United States
- Department of Geology and Environmental Science, University of Pittsburgh, Pittsburgh, Pennsylvania 15260, United States
| | - Sarah-Jane Haig
- Department of Civil and Environmental Engineering, University of Pittsburgh, Pittsburgh, Pennsylvania 15261, United States
- Department of Environmental & Occupational Health, School of Public Health, University of Pittsburgh, Pittsburgh, Pennsylvania 15261, United States
| |
Collapse
|
17
|
Cambronne ED, Ayres C, Dowdell KS, Lawler DF, Saleh NB, Kirisits MJ. Protozoan-Priming and Magnesium Conditioning Enhance Legionella pneumophila Dissemination and Monochloramine Resistance. ENVIRONMENTAL SCIENCE & TECHNOLOGY 2023; 57:14871-14880. [PMID: 37756220 DOI: 10.1021/acs.est.3c04013] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 09/29/2023]
Abstract
Opportunistic pathogens (OPs) are of concern in drinking water distribution systems because they persist despite disinfectant residuals. While many OPs garner protection from disinfectants via a biofilm lifestyle, Legionella pneumophila (Lp) also gains disinfection resistance by being harbored within free-living amoebae (FLA). It has been long established, but poorly understood, that Lp grown within FLA show increased infectivity toward subsequent FLA or human cells (i.e., macrophage), via a process we previously coined "protozoan-priming". The objectives of this study are (i) to identify in Lp a key genetic determinant of how protozoan-priming increases its infectivity, (ii) to determine the chemical stimulus within FLA to which Lp responds during protozoan-priming, and (iii) to determine if more infectious forms of Lp also exhibit enhanced disinfectant resistance. Using Acanthamoeba castellanii as a FLA host, the priming effect was isolated to Lp's sidGV locus, which is activated upon sensing elevated magnesium concentrations. Supplementing growth medium with 8 mM magnesium is sufficient to produce Lp grown in vitro with an infectivity equivalent to that of Lp grown via the protozoan-primed route. Both Lp forms with increased infectivity (FLA-grown and Mg2+-supplemented) exhibit greater monochloramine resistance than Lp grown in standard media, indicating that passage through FLA not only increases Lp's infectivity but also enhances its monochloramine resistance. Therefore, laboratory-based testing of disinfection strategies should employ conditions that simulate or replicate intracellular growth to accurately assess disinfectant resistance.
Collapse
Affiliation(s)
- Eric D Cambronne
- Department of Molecular Biosciences, The University of Texas at Austin, Austin, Texas 78712, United States
| | - Craig Ayres
- Department of Civil, Architectural and Environmental Engineering, The University of Texas at Austin, Austin, Texas 78712, United States
| | - Katherine S Dowdell
- Department of Civil, Architectural and Environmental Engineering, The University of Texas at Austin, Austin, Texas 78712, United States
| | - Desmond F Lawler
- Department of Civil, Architectural and Environmental Engineering, The University of Texas at Austin, Austin, Texas 78712, United States
| | - Navid B Saleh
- Department of Civil, Architectural and Environmental Engineering, The University of Texas at Austin, Austin, Texas 78712, United States
| | - Mary Jo Kirisits
- Department of Civil, Architectural and Environmental Engineering, The University of Texas at Austin, Austin, Texas 78712, United States
| |
Collapse
|
18
|
Ke Y, Sun W, Chen X, Zhu Y, Guo X, Yan W, Xie S. Seasonality Determines the Variations of Biofilm Microbiome and Antibiotic Resistome in a Pilot-Scale Chlorinated Drinking Water Distribution System Deciphered by Metagenome Assembly. ENVIRONMENTAL SCIENCE & TECHNOLOGY 2023; 57:11430-11441. [PMID: 37478472 DOI: 10.1021/acs.est.3c01980] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 07/23/2023]
Abstract
Understanding the biofilm microbiome and antibiotic resistome evolution in drinking water distribution systems (DWDSs) is crucial to ensure the safety of drinking water. We explored the 10 month evolution of the microbial community, antibiotic resistance genes (ARGs), mobile gene elements (MGEs) co-existing with ARGs and pathogenic ARG hosts, and the ARG driving factors in DWDS biofilms using metagenomics assembly. Sampling season was critical in determining the microbial community and antibiotic resistome shift. Pseudomonas was the primary biofilm colonizer, and biofilms diversified more as the formation time increased. Most genera tended to cooperate to adapt to an oligotrophic environment with disinfectant stress. Biofilm microbial community and antibiotic resistome assembly were mainly determined by stochastic processes and changed with season. Metagenome assembly provided the occurrence and fates of MGEs co-existing with ARGs and ARG hosts in DWDS biofilms. The abundance of ARG- and MGE-carrying pathogen Stenotrophomonas maltophilia was high in summer. It primarily harbored the aph(3)-IIb, multidrug transporter, smeD, and metallo-beta-lactamase ARGs, which were transferred via recombination. The microbial community was the most crucial factor driving the antibiotic resistance shift. We provide novel insights about the evolution of pathogens and ARGs and their correlations in DWDS biofilms to ensure the safety of drinking water.
Collapse
Affiliation(s)
- Yanchu Ke
- School of Environment, Tsinghua University, Beijing 100084, China
- State Key Joint Laboratory of Environmental Simulation and Pollution Control, College of Environmental Sciences and Engineering, Peking University, Beijing 100871, China
| | - Wenjun Sun
- School of Environment, Tsinghua University, Beijing 100084, China
- Research Institute for Environmental Innovation (Suzhou) Tsinghua, Suzhou 215163, China
| | - Xiuli Chen
- State Key Joint Laboratory of Environmental Simulation and Pollution Control, College of Environmental Sciences and Engineering, Peking University, Beijing 100871, China
| | - Ying Zhu
- State Key Joint Laboratory of Environmental Simulation and Pollution Control, College of Environmental Sciences and Engineering, Peking University, Beijing 100871, China
| | - Xu Guo
- Fangshan District Water Bureau, Beijing 102445, China
| | - Weixin Yan
- Beijing BiSheng United Water Company, Beijing 102400, China
| | - Shuguang Xie
- State Key Joint Laboratory of Environmental Simulation and Pollution Control, College of Environmental Sciences and Engineering, Peking University, Beijing 100871, China
| |
Collapse
|
19
|
Fang J, Dai Z, Li X, van der Hoek JP, Savic D, Medema G, van der Meer W, Liu G. Service-lines as major contributor to water quality deterioration at customer ends. WATER RESEARCH 2023; 241:120143. [PMID: 37276656 DOI: 10.1016/j.watres.2023.120143] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 03/17/2023] [Revised: 05/16/2023] [Accepted: 05/28/2023] [Indexed: 06/07/2023]
Abstract
Biofilm detachment contributes to water quality deterioration. However, the contributions of biofilm detachment from different pipes have not been quantified or compared. Following the introduction of partial reverse osmosis (RO) in drinking water production, this study analyzed particles at customers' ends and tracked their origins to water distribution mains and service lines. For doing so, filter bags were installed in front of water meters to capture upstream detached particles, while biofilm from water main and service line were sampled by cutting pipe specimens. The results showed that elemental concentrations of the biofilm in mains were higher than those of service lines (54.3-268.5 vs. 27.1-44.4 μg/cm2), both dominated by Ca. Differently, filter bags were dominated by Fe/Mn (77.5-98.1%). After introducing RO, Ca significantly decreased in biofilms of mains but not service lines, but the released Fe/Mn rather than Ca arrived at customers' ends. The ATP concentrations of service lines were higher than mains, which decreased on mains but increased in service lines after introducing RO. For the core ASVs, 13/24 were shared by service lines (17), mains (21), and filter bags (17), which were assigned mainly to Nitrospira spp., Methylomagnum spp., Methylocytis spp., and IheB2-23 spp. According to source tracking results, service lines contributed more than mains to the particulate material collected by filter bags (57.6 ± 13.2% vs. 13.0 ± 11.6%). To the best of our knowledge, the present study provides the first evidence of service lines' direct and quantitative contributions to potential water quality deterioration at customers' ends. This highlights the need for the appropriate management of long-neglected service line pipes, e.g., regarding material selection, length optimization, and proper regulation.
Collapse
Affiliation(s)
- Jiaxing Fang
- Key Lab of Drinking Water Science and Technology, Research Center for Eco-Environmental Sciences, Chinese Academy of Sciences, 100085, Beijing, PR China; Membrane Science and Technology, Faculty of Science and Technology, University of Twente, P.O. Box 217, 7500, AE, Enschede, the Netherlands; Sanitary Engineering, Department of Water Management, Faculty of Civil Engineering and Geosciences, Delft University of Technology, P.O. Box 5048, 2600, GA, Delft, the Netherlands
| | - Zihan Dai
- Key Lab of Drinking Water Science and Technology, Research Center for Eco-Environmental Sciences, Chinese Academy of Sciences, 100085, Beijing, PR China
| | - Xiaoming Li
- Key Lab of Drinking Water Science and Technology, Research Center for Eco-Environmental Sciences, Chinese Academy of Sciences, 100085, Beijing, PR China
| | - Jan Peter van der Hoek
- Sanitary Engineering, Department of Water Management, Faculty of Civil Engineering and Geosciences, Delft University of Technology, P.O. Box 5048, 2600, GA, Delft, the Netherlands; Waternet, P.O. Box 94370, 1090, GJ Amsterdam, the Netherlands
| | - Dragan Savic
- KWR Water Research Institute, P.O. Box 1072, 3430, BB, Nieuwegein, the Netherlands; Centre for Water Systems, University of Exeter, Exeter EX4 4QF, United Kingdom; University of Belgrade, Faculty of Civil Engineering, Department for Hydraulic and environmental engineering, Bulevar kralja Aleksandra 73, Belgrade, Serbia
| | - Gertjan Medema
- Sanitary Engineering, Department of Water Management, Faculty of Civil Engineering and Geosciences, Delft University of Technology, P.O. Box 5048, 2600, GA, Delft, the Netherlands; KWR Water Research Institute, P.O. Box 1072, 3430, BB, Nieuwegein, the Netherlands; Department of Fisheries and Wildlife, Michigan State University, East Lansing, MI, 48823, USA
| | - Walter van der Meer
- Membrane Science and Technology, Faculty of Science and Technology, University of Twente, P.O. Box 217, 7500, AE, Enschede, the Netherlands; Oasen Water Company, PO BOX 122, 2800, AC, Gouda, the Netherlands
| | - Gang Liu
- Key Lab of Drinking Water Science and Technology, Research Center for Eco-Environmental Sciences, Chinese Academy of Sciences, 100085, Beijing, PR China; Sanitary Engineering, Department of Water Management, Faculty of Civil Engineering and Geosciences, Delft University of Technology, P.O. Box 5048, 2600, GA, Delft, the Netherlands.
| |
Collapse
|
20
|
Singh S, Keating C, Ijaz UZ, Hassard F. Molecular insights informing factors affecting low temperature anaerobic applications: Diversity, collated core microbiomes and complexity stability relationships in LCFA-fed systems. THE SCIENCE OF THE TOTAL ENVIRONMENT 2023; 874:162420. [PMID: 36842571 DOI: 10.1016/j.scitotenv.2023.162420] [Citation(s) in RCA: 9] [Impact Index Per Article: 4.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 11/30/2022] [Revised: 01/31/2023] [Accepted: 02/19/2023] [Indexed: 06/18/2023]
Abstract
Fats, oil and grease, and their hydrolyzed counterparts-long chain fatty acids (LCFA) make up a large fraction of numerous wastewaters and are challenging to degrade anaerobically, more so, in low temperature anaerobic digestion (LtAD) systems. Herein, we perform a comparative analysis of publicly available Illumina 16S rRNA datasets generated from LCFA-degrading anaerobic microbiomes at low temperatures (10 and 20 °C) to comprehend the factors affecting microbial community dynamics. The various factors considered were the inoculum, substrate and operational characteristics, the reactor operation mode and reactor configuration, and the type of nucleic acid sequenced. We found that LCFA-degrading anaerobic microbiomes were differentiated primarily by inoculum characteristics (inoculum source and morphology) in comparison to the other factors tested. Inoculum characteristics prominently shaped the species richness, species evenness and beta-diversity patterns in the microbiomes even after long term operation of continuous reactors up to 150 days, implying the choice of inoculum needs careful consideration. The generalised additive models represented through beta diversity contour plots revealed that psychrophilic bacteria RBG-13-54-9 from family Anaerolineae, and taxa WCHB1-41 and Williamwhitmania were highly abundant in LCFA-fed microbial niches, suggesting their role in anaerobic treatment of LCFAs at low temperatures of 10-20 °C. Overall, we showed that the following bacterial genera: uncultured Propionibacteriaceae, Longilinea, Christensenellaceae R7 group, Lactivibrio, candidatus Caldatribacterium, Aminicenantales, Syntrophus, Syntrophomonas, Smithella, RBG-13-54-9, WCHB1-41, Trichococcus, Proteiniclasticum, SBR1031, Lutibacter and Lentimicrobium have prominent roles in LtAD of LCFA-rich wastewaters at 10-20 °C. This study provides molecular insights of anaerobic LCFA degradation under low temperatures from collated datasets and will aid in improving LtAD systems for treating LCFA-rich wastewaters.
Collapse
Affiliation(s)
- Suniti Singh
- Cranfield Water Science Institute, Cranfield University, College Way, Bedfordshire MK43 0AL, UK.
| | - Ciara Keating
- School of Biodiversity, One Health and Veterinary Medicine, College of Medical, Veterinary and Life Sciences, University of Glasgow, UK.
| | - Umer Zeeshan Ijaz
- Infrastructure and Environment Research Division, James Watt School of Engineering, University of Glasgow, UK; Department of Molecular and Clinical Cancer Medicine, University of Liverpool, UK; College of Science and Engineering, NUI Galway, Ireland.
| | - Francis Hassard
- Cranfield Water Science Institute, Cranfield University, College Way, Bedfordshire MK43 0AL, UK; Institute for Nanotechnology and Water Sustainability, University of South Africa, UNISA Science Campus, 1710 Roodepoort, Johannesburg, South Africa.
| |
Collapse
|
21
|
Shim KY, Shin H, Yeo IC, Kim KR, Kwak IS, Jeong CB. Environmental DNA surveillance of biocontamination in a drinking water treatment plant. JOURNAL OF HAZARDOUS MATERIALS 2023; 456:131656. [PMID: 37236104 DOI: 10.1016/j.jhazmat.2023.131656] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 04/25/2023] [Revised: 05/15/2023] [Accepted: 05/16/2023] [Indexed: 05/28/2023]
Abstract
A clean and adequate supply of drinking water is essential to life and good health. However, despite the risk of biologically derived contamination of drinking water, monitoring of invertebrate outbreaks has relied primarily on naked-eye inspections that are prone to errors. In this study, we applied environmental DNA (eDNA) metabarcoding as a biomonitoring tool at seven different stages of drinking water treatment, from prefiltration to release from household faucets. While the composition of invertebrate eDNA communities reflected the communities of the source water in earlier stages of the treatment, several predominant invertebrate taxa (e.g., rotifer) were shown to be introduced during purification, but most were eliminated in later treatment stages. In addition, the limit of detection/quantification of PCR assay and read capacity of high-throughput sequencing was assessed with further microcosm experiments to estimate the applicability eDNA metabarcoding to the biocontamination surveillance in drinking water treatment plants (DWTPs). Here we propose a novel eDNA-based approach for sensitive and efficient surveillance of invertebrate outbreaks in DWTPs.
Collapse
Affiliation(s)
- Kyu-Young Shim
- Department of Marine Science, College of Natural Sciences, Incheon National University, Incheon 22012, Republic of Korea
| | - Heesang Shin
- Department of Marine Science, College of Natural Sciences, Incheon National University, Incheon 22012, Republic of Korea
| | - In-Cheol Yeo
- Department of Marine Science, College of Natural Sciences, Incheon National University, Incheon 22012, Republic of Korea
| | - Kyu Ri Kim
- Hoseo Toxicology Research Center, Hoseo University, Asan 31499, Republic of Korea
| | - Ihn-Sil Kwak
- Department of Ocean Integrated Science, Chonnam National University, Yeosu 59626, Republic of Korea
| | - Chang-Bum Jeong
- Department of Marine Science, College of Natural Sciences, Incheon National University, Incheon 22012, Republic of Korea.
| |
Collapse
|
22
|
Ke Y, Sun W, Jing Z, Zhao Z, Xie S. Seasonal variations of microbial community and antibiotic resistome in a suburb drinking water distribution system in a northern Chinese city. J Environ Sci (China) 2023; 127:714-725. [PMID: 36522100 DOI: 10.1016/j.jes.2022.07.001] [Citation(s) in RCA: 23] [Impact Index Per Article: 11.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/28/2022] [Revised: 06/13/2022] [Accepted: 07/03/2022] [Indexed: 06/17/2023]
Abstract
Antibiotic resistance genes (ARGs) are an emerging issue for drinking water safety. However, the seasonal variation of ARGs in drinking water distribution systems (DWDS) is still unclear. This work revealed the tempo-spatial changes of microbial community, ARGs, mobile genetic elements (MGEs) co-occurring with ARGs, ARG hosts in DWDS bulk water by means of metagenome assembly. The microbial community and antibiotic resistome varied with sampling season and site. Temperature, ammonia, chlorite and total plate count (TPC) drove the variations of microbial community structure. Moreover, environmental parameters (total organic carbon (TOC), chlorite, TPC and hardness) shifted antibiotic resistome. ARGs and MGEs co-occurring with ARGs showed higher relative abundance in summer and autumn, which might be attributed to detached pipe biofilm. In particular, ARG-bacitracin and plasmid were the predominant ARG and MGE, respectively. ARG hosts changed with season and site and were more diverse in summer and autumn. In winter and spring, Limnohabitans and Mycobacterium were the major ARG hosts as well as the dominant genera in microbial community. In addition, in summer and autumn, high relative abundance of Achromobacter and Stenotrophomonas were the hosts harboring many kinds of ARGs and MGEs at site in a residential zone (0.4 km from the water treatment plant). Compared with MGEs, microbial community had a greater contribution to the variation of antibiotic resistome. This work gives new insights into the dynamics of ARGs in full-scale DWDS and the underlying factors.
Collapse
Affiliation(s)
- Yanchu Ke
- State Key Joint Laboratory of Environmental Simulation and Pollution Control, College of Environmental Sciences and Engineering, Peking University, Beijing 100871, China; School of Environment, Tsinghua University, Beijing 100084, China
| | - Wenjun Sun
- School of Environment, Tsinghua University, Beijing 100084, China; Research Institute for Environmental Innovation (Suzhou) Tsinghua, Suzhou 215163, China.
| | - Zibo Jing
- School of Environment, Tsinghua University, Beijing 100084, China
| | - Zhinan Zhao
- School of Environment, Tsinghua University, Beijing 100084, China
| | - Shuguang Xie
- State Key Joint Laboratory of Environmental Simulation and Pollution Control, College of Environmental Sciences and Engineering, Peking University, Beijing 100871, China.
| |
Collapse
|
23
|
Ke Y, Sun W, Jing Z, Zhu Y, Zhao Z, Xie S. Antibiotic resistome alteration along a full-scale drinking water supply system deciphered by metagenome assembly: Regulated by seasonality, mobile gene elements and antibiotic resistant gene hosts. THE SCIENCE OF THE TOTAL ENVIRONMENT 2023; 862:160887. [PMID: 36521611 DOI: 10.1016/j.scitotenv.2022.160887] [Citation(s) in RCA: 20] [Impact Index Per Article: 10.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 10/03/2022] [Revised: 12/07/2022] [Accepted: 12/08/2022] [Indexed: 06/17/2023]
Abstract
Both drinking water treatment processes and distribution can lead to antibiotic resistome variation, yet the variation of antibiotic resistome in the whole drinking water supply system (DWSS) combined with seasonality remains unknown. In this study, microbial community, antibiotic resistome, mobile genetic elements (MGEs) co-existing with antibiotic resistance genes (ARGs) and ARG hosts would be explored along a DWSS for four seasons with metagenome assembly. Multidrug and bacitracin ARGs were dominant ARGs in DWSS. Integrase, plasmids, recombinase and transposase were major MGEs co-existing with ARGs. Filtration and disinfection treatments could alter the ARG relative abundance, mainly via changing the abundance of ARG hosts (Limnohabitans and Polynucleobacter), which was influenced by water total organic carbon (TOC) content. When TOC was relatively high, filtration could proliferate ARGs via promoting antibiotic resistance bacteria (ARB) but chlorine dioxide could decrease ARGs via killing ARB. Filtration played an important role in controlling ARGs by reducing ARB when TOC was relatively low. The stimulation effect of disinfection on ARGs existed in more oligotrophic environment. Distribution could enrich ARGs in higher temperature by increasing MGEs co-occurring with ARGs and diversifying ARG hosts. MGEs co-occurring with ARGs became more abundant and diverse in disinfected water in warmer seasons. Microbial community was the most important factor determining the antibiotic resistome along a DWSS. These findings extend the knowledge about how and why water treatment processes and pipe distribution shape drinking water antibiotic resistome in different seasons.
Collapse
Affiliation(s)
- Yanchu Ke
- State Key Joint Laboratory of Environmental Simulation and Pollution Control, College of Environmental Sciences and Engineering, Peking University, Beijing 100871, China; School of Environment, Tsinghua University, Beijing 100084, China
| | - Wenjun Sun
- School of Environment, Tsinghua University, Beijing 100084, China; Research Institute for Environmental Innovation (Suzhou) Tsinghua, Suzhou 215163, China.
| | - Zibo Jing
- School of Environment, Tsinghua University, Beijing 100084, China
| | - Yin Zhu
- State Key Joint Laboratory of Environmental Simulation and Pollution Control, College of Environmental Sciences and Engineering, Peking University, Beijing 100871, China
| | - Zhinan Zhao
- School of Environment, Tsinghua University, Beijing 100084, China
| | - Shuguang Xie
- State Key Joint Laboratory of Environmental Simulation and Pollution Control, College of Environmental Sciences and Engineering, Peking University, Beijing 100871, China.
| |
Collapse
|
24
|
Zeng H, Shen S, Cai A, Sun Q, Wang L, Zhu S, Li X, Deng J. Degradation of tetracycline by UV/Fe 3+/persulfate process: Kinetics, mechanism, DBPs yield, toxicity evaluation and bacterial community analysis. CHEMOSPHERE 2022; 307:136072. [PMID: 35988766 DOI: 10.1016/j.chemosphere.2022.136072] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 06/03/2022] [Revised: 07/21/2022] [Accepted: 08/11/2022] [Indexed: 06/15/2023]
Abstract
As a widely produced and used antibiotic, tetracycline (TC) has been frequently found in rivers, soil and drinking water. In this study, the degradation of TC was investigated by UV/Fe3+/persulfate (PS) coupled process. The degradation behavior was well fitted with pseudo-first-order model. Hydroxyl radicals (·OH), sulfate radicals (SO4-·) and superoxide radical (O2-·) were identified as the primary reactive oxygen species (ROS) in UV/Fe3+/PS process, the contribution to TC degradation were found to be 41.94%, 33.94% and 17.44% at pH 3.0, respectively. Fe(IV) generated from the system also played a crucial role in TC removal. The effects of process parameters (PS/Fe3+ dosages, pH, humic acid, Cl-, HCO3-, NO3- and CO32-) on degradation were investigated. It was found that the degradation of TC was highly pH-dependent, and the optimal performance was obtained at pH 3.0. Except for Cl-, the presence of HA, HCO3-, NO3- and CO32- inhibited TC degradation. The possible transformation pathway involving the hydroxylation, N-demethylation, hydrogenation and dehydroxylation was proposed. Furthermore, the toxicity and mutagenicity of TC and transformation products (TPs) were estimated using ECOSAR and TEST softwares, demonstrating that the toxicity level of most TPs was lower/equal to their precursors. The evaluation of DBPs showed that UV/Fe3+/PS process could reduce the potential of DBPs formation, especially for TCAA and TCM. Microbial community composition was analyzed by 16 S rDNA sequencing, and the relative abundance of ARG-carrying opportunistic pathogens was significantly declined after UV/Fe3+/PS treatment. In general, this study provides an economical, efficient and safe strategy for TC removal.
Collapse
Affiliation(s)
- Hanxuan Zeng
- College of Civil Engineering, Zhejiang University of Technology, Hangzhou, 310023, China
| | - Shuwen Shen
- College of Civil Engineering, Zhejiang University of Technology, Hangzhou, 310023, China
| | - Anhong Cai
- College of Civil Engineering, Zhejiang University of Technology, Hangzhou, 310023, China
| | - Qian Sun
- Afflicated Zhejiang Hospital, Zhejiang University School of Medicine, Hangzhou, 310013, China
| | - Lei Wang
- College of Civil Engineering, Zhejiang University of Technology, Hangzhou, 310023, China
| | - Shijun Zhu
- College of Civil Engineering, Zhejiang University of Technology, Hangzhou, 310023, China
| | - Xueyan Li
- School of Environmental Science and Engineering, Suzhou University of Science and Technology, Suzhou, 215009, China
| | - Jing Deng
- College of Civil Engineering, Zhejiang University of Technology, Hangzhou, 310023, China.
| |
Collapse
|
25
|
Trego A, Keating C, Nzeteu C, Graham A, O’Flaherty V, Ijaz UZ. Beyond Basic Diversity Estimates-Analytical Tools for Mechanistic Interpretations of Amplicon Sequencing Data. Microorganisms 2022; 10:1961. [PMID: 36296237 PMCID: PMC9609705 DOI: 10.3390/microorganisms10101961] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/17/2022] [Revised: 09/29/2022] [Accepted: 09/30/2022] [Indexed: 11/07/2022] Open
Abstract
Understanding microbial ecology through amplifying short read regions, typically 16S rRNA for prokaryotic species or 18S rRNA for eukaryotic species, remains a popular, economical choice. These methods provide relative abundances of key microbial taxa, which, depending on the experimental design, can be used to infer mechanistic ecological underpinnings. In this review, we discuss recent advancements in in situ analytical tools that have the power to elucidate ecological phenomena, unveil the metabolic potential of microbial communities, identify complex multidimensional interactions between species, and compare stability and complexity under different conditions. Additionally, we highlight methods that incorporate various modalities and additional information, which in combination with abundance data, can help us understand how microbial communities respond to change in a typical ecosystem. Whilst the field of microbial informatics continues to progress substantially, our emphasis is on popular methods that are applicable to a broad range of study designs. The application of these methods can increase our mechanistic understanding of the ongoing dynamics of complex microbial communities.
Collapse
Affiliation(s)
- Anna Trego
- Microbial Ecology Laboratory, School of Biological and Chemical Sciences and the Ryan Institute, University of Galway, University Road, H91 TK33 Galway, Ireland
| | - Ciara Keating
- Institute of Biodiversity, Animal Health & Comparative Medicine, The University of Glasgow, Oakfield Avenue, Glasgow G12 8LT, UK
| | - Corine Nzeteu
- Microbial Ecology Laboratory, School of Biological and Chemical Sciences and the Ryan Institute, University of Galway, University Road, H91 TK33 Galway, Ireland
| | - Alison Graham
- Microbial Ecology Laboratory, School of Biological and Chemical Sciences and the Ryan Institute, University of Galway, University Road, H91 TK33 Galway, Ireland
| | - Vincent O’Flaherty
- Microbial Ecology Laboratory, School of Biological and Chemical Sciences and the Ryan Institute, University of Galway, University Road, H91 TK33 Galway, Ireland
| | - Umer Zeeshan Ijaz
- Water Engineering Group, School of Engineering, The University of Glasgow, Oakfield Avenue, Glasgow G12 8LT, UK
| |
Collapse
|
26
|
A meta-analysis of acetogenic and methanogenic microbiomes in microbial electrosynthesis. NPJ Biofilms Microbiomes 2022; 8:73. [PMID: 36138044 PMCID: PMC9500080 DOI: 10.1038/s41522-022-00337-5] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/07/2021] [Accepted: 09/09/2022] [Indexed: 11/24/2022] Open
Abstract
A meta-analysis approach was used, to study the microbiomes of biofilms and planktonic communities underpinning microbial electrosynthesis (MES) cells. High-throughput DNA sequencing of 16S rRNA gene amplicons has been increasingly applied to understand MES systems. In this meta-analysis of 22 studies, we find that acetogenic and methanogenic MES cells share 80% of a cathodic core microbiome, and that different inoculum pre-treatments strongly affect community composition. Oxygen scavengers were more abundant in planktonic communities, and several key organisms were associated with operating parameters and good cell performance. We suggest Desulfovibrio sp. play a role in initiating early biofilm development and shaping microbial communities by catalysing H2 production, to sustain either Acetobacterium sp. or Methanobacterium sp. Microbial community assembly became more stochastic over time, causing diversification of the biofilm (cathodic) community in acetogenic cells and leading to re-establishment of methanogens, despite inoculum pre-treatments. This suggests that repeated interventions may be required to suppress methanogenesis.
Collapse
|
27
|
Ecological Observations Based on Functional Gene Sequencing Are Sensitive to the Amplicon Processing Method. mSphere 2022; 7:e0032422. [PMID: 35938727 PMCID: PMC9429940 DOI: 10.1128/msphere.00324-22] [Citation(s) in RCA: 7] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/04/2023] Open
Abstract
Until recently, the de facto method for short-read-based amplicon reconstruction was a sequence similarity threshold approach (operational taxonomic units [OTUs]). This has changed with the amplicon sequence variant (ASV) method where distributions are fitted to abundance profiles of individual genes using a noise-error model. While OTU-based approaches are still useful for 16S rRNA/18S rRNA genes, where thresholds of 97% to 99% are used, their use for functional genes is still debatable as there is no consensus on clustering thresholds. Here, we compare OTU- and ASV-based reconstruction approaches and taxonomy assignment methods, the naive Bayesian classifier (NBC) and Bayesian lowest common ancestor (BLCA) algorithm, using a functional gene data set from the microbial nitrogen-cycling community in the Brouage mudflat (France). A range of OTU similarity thresholds and ASVs were used to compare amoA (ammonia-oxidizing archaea [AOA] and ammonia-oxidizing bacteria [AOB]), nxrB, nirS, nirK, and nrfA communities between differing sedimentary structures. Significant effects of the sedimentary structure on weighted UniFrac (WUniFrac) distances were observed for AOA amoA when using ASVs, an OTU at a threshold of 97% sequence identity (OTU-97%), and OTU-85%; AOB amoA when using OTU-85%; and nirS when using ASV, OTU-90%, and OTU-85%. For AOB amoA, significant effects of the sedimentary structures on UniFrac distances were observed when using OTU-97% but not ASVs, and the inverse was found for nrfA. Interestingly, conclusions drawn for nirK and nxrB were consistent between amplicon reconstruction methods. We also show that when the sequences in the reference database are related to the environment in question, the BLCA algorithm leads to more phylogenetically relevant classifications. However, when the reference database contains sequences more dissimilar to the ones retrieved, the NBC obtains more information. IMPORTANCE Several analysis pipelines are available to microbial ecologists to process amplicon sequencing data, yet to date, there is no consensus as to the most appropriate method, and it becomes more difficult for genes that encode a specific function (functional genes). Standardized approaches need to be adopted to increase the reliability and reproducibility of environmental amplicon-sequencing-based data sets. In this paper, we argue that the recently developed ASV approach offers a better opportunity to achieve such standardization than OTUs for functional genes. We also propose a comprehensive framework for quality filtering of the sequencing reads based on protein sequence verification.
Collapse
|
28
|
Bruno A, Agostinetto G, Fumagalli S, Ghisleni G, Sandionigi A. It’s a Long Way to the Tap: Microbiome and DNA-Based Omics at the Core of Drinking Water Quality. INTERNATIONAL JOURNAL OF ENVIRONMENTAL RESEARCH AND PUBLIC HEALTH 2022; 19:ijerph19137940. [PMID: 35805598 PMCID: PMC9266242 DOI: 10.3390/ijerph19137940] [Citation(s) in RCA: 9] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 04/30/2022] [Revised: 06/17/2022] [Accepted: 06/24/2022] [Indexed: 11/16/2022]
Abstract
Microbial communities interact with us and affect our health in ways that are only beginning to be understood. Microorganisms have been detected in every ecosystem on Earth, as well as in any built environment that has been investigated. Drinking water sources, drinking water treatment plants and distribution systems provide peculiar microbial ecological niches, dismantling the belief of the “biological simplicity” of drinking water. Nevertheless, drinking water microbiomes are understudied compared to other microbiomes. Recent DNA sequencing and meta-omics advancements allow a deeper understanding of drinking water microbiota. Thus, moving beyond the limits of day-to-day testing for specific pathogenic microbes, new approaches aim at predicting microbiome changes driven by disturbances at the macro-scale and overtime. This will foster an effective and proactive management of water sources, improving the drinking water supply system and the monitoring activities to lower public health risk. Here, we want to give a new angle on drinking water microbiome research. Starting from a selection of 231 scientific publications on this topic, we emphasize the value of biodiversity in drinking water ecosystems and how it can be related with industrialization. We then discuss how microbiome research can support sustainable drinking water management, encouraging collaborations across sectors and involving the society through responsible research and innovation.
Collapse
Affiliation(s)
- Antonia Bruno
- Biotechnology and Biosciences Department, University of Milano-Bicocca, 20126 Milan, Italy; (G.A.); (S.F.); (G.G.)
- Correspondence:
| | - Giulia Agostinetto
- Biotechnology and Biosciences Department, University of Milano-Bicocca, 20126 Milan, Italy; (G.A.); (S.F.); (G.G.)
| | - Sara Fumagalli
- Biotechnology and Biosciences Department, University of Milano-Bicocca, 20126 Milan, Italy; (G.A.); (S.F.); (G.G.)
| | - Giulia Ghisleni
- Biotechnology and Biosciences Department, University of Milano-Bicocca, 20126 Milan, Italy; (G.A.); (S.F.); (G.G.)
- Institut Jacques Monod, Université Paris Cité, CNRS, 75013 Paris, France
| | | |
Collapse
|