1
|
Liu C, Hu Y, Chen Y, Fang J, Liu R, Bi L, Tan X, Sheng B, Wu Q. Improvements to a GLCM-based machine-learning approach for quantifying posterior capsule opacification. J Appl Clin Med Phys 2024; 25:e14268. [PMID: 38259111 PMCID: PMC10860560 DOI: 10.1002/acm2.14268] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/08/2023] [Revised: 12/26/2023] [Accepted: 01/02/2024] [Indexed: 01/24/2024] Open
Abstract
BACKGROUND Posterior capsular opacification (PCO) is a common complication following cataract surgery that leads to visual disturbances and decreased quality of vision. The aim of our study was to employ a machine-learning methodology to characterize and validate enhancements applied to the grey-level co-occurrence matrix (GLCM) while assessing its validity in comparison to clinical evaluations for evaluating PCO. METHODS One hundred patients diagnosed with age-related cataracts who were scheduled for phacoemulsification surgery were included in the study. Following mydriasis, anterior segment photographs were captured using a high-resolution photographic system. The GLCM was utilized as the feature extractor, and a supported vector machine as the regressor. Three variations, namely, GLCM, GLCM+C (+axial information), and GLCM+V (+regional voting), were analyzed. The reference value for regression was determined by averaging clinical scores obtained through subjective analysis. The relationships between the predicted PCO outcome scores and the ground truth were assessed using Pearson correlation analysis and a Bland-Altman plot, while agreement between them was assessed through the Bland-Altman plot. RESULTS Relative to the ground truth, the GLCM, GLCM+C, and GLCM+V methods exhibited correlation coefficients of 0.706, 0.768, and 0.829, respectively. The relationship between the PCO score predicted by the GLCM+V method and the ground truth was statistically significant (p < 0.001). Furthermore, the GLCM+V method demonstrated competitive performance comparable to that of two experienced clinicians (r = 0.825, 0.843) and superior to that of two junior clinicians (r = 0.786, 0.756). Notably, a high level of agreement was observed between predictions and the ground truth, without significant evidence of proportional bias (p > 0.05). CONCLUSIONS Overall, our findings suggest that a machine-learning approach incorporating the GLCM, specifically the GLCM+V method, holds promise as an objective and reliable tool for assessing PCO progression. Further studies in larger patient cohorts are warranted to validate these findings and explore their potential clinical applications.
Collapse
Affiliation(s)
- Chang Liu
- Department of Ophthalmology, Shanghai Sixth People's Hospital Affiliated to Shanghai Jiao Tong University School of Medicine, Shanghai, China
| | - Ying Hu
- Department of Ophthalmology, Shanghai Sixth People's Hospital Affiliated to Shanghai Jiao Tong University School of Medicine, Shanghai, China
| | - Yan Chen
- Department of Ophthalmology, Shanghai Sixth People's Hospital Affiliated to Shanghai Jiao Tong University School of Medicine, Shanghai, China
| | - Jian Fang
- Department of Ophthalmology, Shanghai Sixth People's Hospital Affiliated to Shanghai Jiao Tong University School of Medicine, Shanghai, China
| | - Ruhan Liu
- Furong Laboratory, Central South University, Changsha, Hunan, China
| | - Lei Bi
- Institute of Translational Medicine, Shanghai Jiao Tong University, Shanghai, China
| | - Xunan Tan
- Shanghai University of Sport School of Exercise and Health, Shanghai, China
| | - Bin Sheng
- Department of Computer Science and Engineering, Shanghai Jiao Tong University, Shanghai, China
| | - Qiang Wu
- Department of Ophthalmology, Shanghai Sixth People's Hospital Affiliated to Shanghai Jiao Tong University School of Medicine, Shanghai, China
| |
Collapse
|
2
|
Application of Spectral Domain Optical Coherence Tomography to Objectively Evaluate Posterior Capsular Opacity In Vivo. J Ophthalmol 2019; 2018:5461784. [PMID: 30671258 PMCID: PMC6323435 DOI: 10.1155/2018/5461784] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/30/2018] [Revised: 09/19/2018] [Accepted: 11/11/2018] [Indexed: 01/19/2023] Open
Abstract
Objectives To objectively evaluate posterior capsular opacification (PCO) with RTVue-100 spectral domain-OCT and assess the agreement with the Pentacam system. Methods Sixty-seven eyes diagnosed with PCO were included. RTVue-100 SD-OCT was used to scan the IOL outline and PCO at horizontal and vertical meridians. PCO was also imaged with a Pentacam and slit-lamp photography system. With RTVue-100 SD-OCT, the PCO area, thickness, density, and objective scores were recorded and used to evaluate the severity of PCO at 3 mm and 5 mm diameter ranges of the IOL optic region. We assessed the correlation of visual acuity, PCO characteristics, and PCO scores. PCO scores acquired from RTVue-100 SD-OCT images were also compared with those from the Pentacam. Differences between pear-type and fibrosis-type PCOs were also compared using RTVue-100 SD-OCT cross-sectional images. Results The cross-sectional images of PCO acquired with RTVue-100 SD-OCT corresponded well to Pentacam and slit-lamp retroillumination images. IOL-posterior capsular space, area, thickness, and density of the proliferated and accumulated LECs could be clearly visualized and quantified with RTVue-100 SD-OCT. PCO scores were correlated with decreased visual acuity, which was in line with the outcomes using the Pentacam. Differences between the pear-type and fibrosis-type PCO were statistically significant; pear-type PCOs showed a wider and thicker opacification region with lower density compared with fibrosis-type PCOs. Conclusion RTVue-100 SD-OCT could be a powerful tool in PCO objective evaluation and classification. OCT could be used to visualize the morphology and outline of PCO. Thus, it could discriminate and quantify differences between different types of PCO. PCO scores seem to be a useful factor that could reliably reflect PCO severity.
Collapse
|
3
|
Alberdi T, Mendicute J, Bascarán L, Barandika O, Ruiz-Ederra J. Anterior and posterior capsule densitometry levels after femtosecond laser-assisted cataract surgery. Int J Ophthalmol 2018; 11:623-628. [PMID: 29675381 DOI: 10.18240/ijo.2018.04.14] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/03/2017] [Accepted: 12/12/2017] [Indexed: 11/23/2022] Open
Abstract
AIM To analyze and compare five different variables over one year follow-up (1wk, 1, 3, 6 and 12mo): anterior capsule (AC), and posterior capsule (PC) area densitometry values, AC and PC linear densitometry values, and AC opening area reduction ratio after femtosecond laser-assisted cataract surgery. METHODS This was a prospective comparative study. Seventy-one patients underwent femtosecond laser-assisted cataract surgery on single eye between June 2014 and December 2015. A 5.0 mm diameter laser assisted anterior capsulotomy was performed on all eyes. In every post-surgery evaluation, AC opacificaction (ACO) and PC opacification (PCO) density levels were provided by Oculus Pentacam®HR using area and linear densitometry methods. Digital images were captured with a slit-lamp Topcon photographic camera and IMAGEnet® 5 software. The AC opening area on the digital images was measured using the Sketchandcalc area calculator and converted to reduction ratio levels. RESULTS Using Pearson correlation coefficient (PCC), we found no correlation (r=-0.091, P=0.46) in the twelfth month assessment between the evolution of ACO area densitometry values and PCO area densitometry values considered as independent variables. We found no correlation, using PCC (r=-0.096, P=0.43) between the evolution of ACO linear densitometry values and PCO linear densitometry values, in the twelfth month visit, working both as independent variables. AC linear densitometry levels and AC area densitometry levels continued to grow strongly from sixth to twelfth months. Analysis of the values of AC opening area reduction ratio (1wk, 1, 3, 6, 12mo) revealed statistically significant differences between the values of successive examinations but the magnitude of the change decreased. In the final period of monitoring between six and twelve months the magnitude of change was low. CONCLUSION Our results show strong increases of Scheimpflug ACO densitometry values from the sixth to the twelfth month while capsulorhexis area reduction ratio levels displayed a considerable decrease. We found no correlation between ACO area and linear densitometry values and PCO area and linear densitometry values, in the twelfth month examination, working as independent variables.
Collapse
Affiliation(s)
- Txomin Alberdi
- Department of Ophthalmology, Donostia University Hospital, Donostia-San Sebastian 20014, Spain
| | - Javier Mendicute
- Department of Ophthalmology, Donostia University Hospital, Donostia-San Sebastian 20014, Spain
| | - Lucía Bascarán
- Department of Ophthalmology, Donostia University Hospital, Donostia-San Sebastian 20014, Spain
| | - Olatz Barandika
- Biodonostia Health Research Institute, Donostia-San Sebastian 20014, Spain
| | - Javier Ruiz-Ederra
- Biodonostia Health Research Institute, Donostia-San Sebastian 20014, Spain
| |
Collapse
|
4
|
Alberdi T, Mendicute J, Bascarán L, Goñi N, Barandika O, Ruiz-Ederra J. Anterior capsule opacification after femtosecond laser-assisted cataract surgery: Clinical classification versus Scheimpflug device densitometry values. J Cataract Refract Surg 2016; 42:826-32. [PMID: 27373388 DOI: 10.1016/j.jcrs.2016.03.037] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/11/2016] [Revised: 02/26/2016] [Accepted: 03/02/2016] [Indexed: 11/18/2022]
Abstract
PURPOSE To compare the clinical classification of anterior capsule opacification (ACO) after femtosecond laser-assisted cataract surgery with the mean density values of ACO provided by rotating Scheimpflug device (Pentacam HR) densitometry software and to determine which densitometry method correlates best with the clinical classification. SETTING Ophthalmology Department, Donostia University Hospital, Donostia-San Sebastian, Spain. DESIGN Prospective comparative study. METHODS Femtosecond laser-assisted cataract surgery was performed using the Victus platform between June 2014 and March 2015. Inclusion criteria were age between 55 years and 85 years, a pupil diameter larger than 6.0 mm in full mydriasis, no intraoperative complications, a curvilinear anterior capsulotomy without tears, and an intraocular lens in the correct intracapsular position at the end surgery. The ACO was measured by a clinical classification ranging from 0 to 4. In addition, ACO density was measured with the Scheimpflug device using 3 densitometry methods (area, linear, and peak). RESULTS The study comprised 32 eyes of 32 patients. Area and linear densitometry values provided by the Scheimpflug device had a strong correlation with the values obtained by clinical classification, whereas peak densitometry values had a very weak correlation at 6 months (area densitometry: Spearman ρ = 0.78; P < .0005; linear densitometry: ρ = 0.73; P < .0005; peak densitometry ρ = 0.21; P = .2). CONCLUSION The Scheimpflug device provided an objective measurement of ACO after cataract surgery. FINANCIAL DISCLOSURE None of the authors has a financial or proprietary interest in any material or method mentioned.
Collapse
Affiliation(s)
- Txomin Alberdi
- From the Ophthalmology Department (Alberdi, Mendicute, Bascarán, Goñi), Donostia Universitary Hospital, and the Biodonostia Health Research Institute (Barandika, Ruiz Ederra), Donostia-San Sebastian, Spain.
| | - Javier Mendicute
- From the Ophthalmology Department (Alberdi, Mendicute, Bascarán, Goñi), Donostia Universitary Hospital, and the Biodonostia Health Research Institute (Barandika, Ruiz Ederra), Donostia-San Sebastian, Spain
| | - Lucía Bascarán
- From the Ophthalmology Department (Alberdi, Mendicute, Bascarán, Goñi), Donostia Universitary Hospital, and the Biodonostia Health Research Institute (Barandika, Ruiz Ederra), Donostia-San Sebastian, Spain
| | - Nahia Goñi
- From the Ophthalmology Department (Alberdi, Mendicute, Bascarán, Goñi), Donostia Universitary Hospital, and the Biodonostia Health Research Institute (Barandika, Ruiz Ederra), Donostia-San Sebastian, Spain
| | - Olatz Barandika
- From the Ophthalmology Department (Alberdi, Mendicute, Bascarán, Goñi), Donostia Universitary Hospital, and the Biodonostia Health Research Institute (Barandika, Ruiz Ederra), Donostia-San Sebastian, Spain
| | - Javier Ruiz-Ederra
- From the Ophthalmology Department (Alberdi, Mendicute, Bascarán, Goñi), Donostia Universitary Hospital, and the Biodonostia Health Research Institute (Barandika, Ruiz Ederra), Donostia-San Sebastian, Spain
| |
Collapse
|
5
|
Tan X, Lin H, Lin Z, Chen J, Tang X, Luo L, Chen W, Liu Y. Capsular Outcomes After Pediatric Cataract Surgery Without Intraocular Lens Implantation: Qualitative Classification and Quantitative Measurement. Medicine (Baltimore) 2016; 95:e2993. [PMID: 26962807 PMCID: PMC4998888 DOI: 10.1097/md.0000000000002993] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 12/29/2022] Open
Abstract
The objective of this study was to investigate capsular outcomes 12 months after pediatric cataract surgery without intraocular lens implantation via qualitative classification and quantitative measurement.This study is a cross-sectional study that was approved by the institutional review board of Zhongshan Ophthalmic Center of Sun Yat-sen University in Guangzhou, China.Digital coaxial retro-illumination photographs of 329 aphakic pediatric eyes were obtained 12 months after pediatric cataract surgery without intraocular lens implantation. Capsule digital coaxial retro-illumination photographs were divided as follows: anterior capsule opening area (ACOA), posterior capsule opening area (PCOA), and posterior capsule opening opacity (PCOO). Capsular outcomes were qualitatively classified into 3 types based on the PCOO: Type I-capsule with mild opacification but no invasion into the capsule opening; Type II-capsule with moderate opacification accompanied by contraction of the ACOA and invasion to the occluding part of the PCOA; and Type III-capsule with severe opacification accompanied by total occlusion of the PCOA. Software was developed to quantitatively measure the ACOA, PCOA, and PCOO using standardized DCRPs. The relationships between the accurate intraoperative anterior and posterior capsulorhexis sizes and the qualitative capsular types were statistically analyzed.The DCRPs of 315 aphakic eyes (95.8%) of 191 children were included. Capsular outcomes were classified into 3 types: Type I-120 eyes (38.1%); Type II-157 eyes (49.8%); Type III-38 eyes (12.1%). The scores of the capsular outcomes were negatively correlated with intraoperative anterior capsulorhexis size (R = -0.572, P < 0.001), but no significant correlation with intraoperative posterior capsulorhexis size (R = -0.16, P = 0.122) was observed. The ACOA significantly decreased from Type I to Type II to Type III, the PCOA increased in size from Type I to Type II, and the PCOO increased from Type II to Type III (all P < 0.05).Capsular outcomes after pediatric cataract surgery can be qualitatively classified and quantitatively measured by acquisition, division, definition, and user-friendly software analyses of high-quality digital coaxial retro-illumination photographs.
Collapse
Affiliation(s)
- Xuhua Tan
- From the State Key Laboratory of Ophthalmology, Zhongshan Ophthalmic Center, Sun Yat-sen University, Guangzhou, China
| | | | | | | | | | | | | | | |
Collapse
|
6
|
Miyata K, Kataoka Y, Matsunaga J, Honbo M, Minami K. Prospective Comparison of One-Piece and Three-Piece Tecnis Aspheric Intraocular Lenses: 1-year Stability and its Effect on Visual Function. Curr Eye Res 2014; 40:930-5. [PMID: 25310136 DOI: 10.3109/02713683.2014.968936] [Citation(s) in RCA: 16] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/13/2022]
Abstract
PURPOSE To compare the stability and visual function of one-piece hydrophobic intraocular lens (IOL) (ZCB00, Abbot Medical Optics) and a three-piece hydrophobic IOL (ZA9003, Abbot Medical Optics) after cataract surgery. MATERIALS AND METHODS Eighteen eyes of 18 patients with the one-piece IOL and 20 eyes of 20 patients with the three-piece IOL who underwent cataract surgery were evaluated prospectively on best corrected distance visual acuity, postoperative refractive error, IOL decentration and tilt, anterior chamber depth (ACD), spherical aberration and contrast sensitivity. Measurements were performed 1 week and 1, 3, 6 and 12 months postoperatively. The postoperative outcomes were compared between the two groups. RESULTS In the one-piece group, a hyperopic refractive error (p < 0.002) and deeper ACDs during 1-year post-operatively were observed compared with the three-piece group. There were no significant differences in BCVA, IOL tilt, spherical aberration or contrast sensitivity. CONCLUSIONS The stability of the one-piece IOL was greater than that of the three-piece IOL. The postoperative ACD and refractive error demonstrated that an anteriorly offset haptic in the one-piece IOL allowed incremental fixation to the posterior capsule.
Collapse
|
7
|
Minami K, Maruyama Y, Honbo M, Matsunaga J, Miyata K. In vitro examination of surface light scattering in hydrophobic acrylic intraocular lenses. J Cataract Refract Surg 2014; 40:652-6. [DOI: 10.1016/j.jcrs.2013.10.034] [Citation(s) in RCA: 9] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/17/2013] [Revised: 09/28/2013] [Accepted: 10/20/2013] [Indexed: 11/27/2022]
|
8
|
Miyata K, Honbo M, Otani S, Nejima R, Minami K. Effect on visual acuity of increased surface light scattering in intraocular lenses. J Cataract Refract Surg 2012; 38:221-6. [PMID: 22322162 DOI: 10.1016/j.jcrs.2011.08.042] [Citation(s) in RCA: 34] [Impact Index Per Article: 2.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/05/2011] [Revised: 08/02/2011] [Accepted: 08/18/2011] [Indexed: 10/14/2022]
Abstract
PURPOSE To assess the long-term increase in surface light scattering of foldable hydrophobic acrylic intraocular lenses (IOLs) and to evaluate its effect on visual acuity. SETTING Miyata Eye Hospital, Miyazaki, Japan. DESIGN Cross-sectional study. METHODS The clinical records of patients who received an Acrysof IOL (study group) or a Sensar AR40 or AR40e IOL (control group) were reviewed retrospectively. Surface light scattering of IOLs was measured 1 year postoperatively or later. The corrected distance visual acuity (CDVA) at the surface-light-scattering examination was compared with the CDVA 1 month after IOL implantation. The changes in CDVA over time were compared with the increase in surface light scattering. RESULTS The study evaluated 466 eyes of 337 patients. Surface light scattering in the study group continued to increase up to 15 years postoperatively. The light scattering was higher on the anterior IOL surface after 4.5 years. Increased surface light scattering had no significant impact on CDVA; however, there were more cases with decreased CDVA when the surface light scattering exceeded 50 computer-compatible tape steps. CONCLUSION Surface light scattering with the implanted foldable hydrophobic acrylic IOL continuously increased during the postoperative years and was a risk for decreased visual acuity.
Collapse
|
9
|
Wakamatsu TH, Yamaguchi T, Negishi K, Kaido M, Matsumoto Y, Ishida R, Kojima T, Ibrahim OMA, Saiki M, Dogru M, Tsubota K. Functional visual acuity after neodymium:YAG laser capsulotomy in patients with posterior capsule opacification and good visual acuity preoperatively. J Cataract Refract Surg 2011; 37:258-64. [DOI: 10.1016/j.jcrs.2010.08.048] [Citation(s) in RCA: 20] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/07/2010] [Revised: 08/19/2010] [Accepted: 08/22/2010] [Indexed: 10/18/2022]
|
10
|
Werghi N, Sammouda R, AlKirbi F. An unsupervised learning approach based on a Hopfield-like network for assessing posterior capsule opacification. Pattern Anal Appl 2010. [DOI: 10.1007/s10044-010-0181-y] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/19/2022]
|
11
|
Ohtani S, Gekka S, Honbou M, Kataoka Y, Minami K, Miyata K, Oshika T. One-year prospective intrapatient comparison of aspherical and spherical intraocular lenses in patients with bilateral cataract. Am J Ophthalmol 2009; 147:984-9, 989.e1. [PMID: 19285656 DOI: 10.1016/j.ajo.2008.12.037] [Citation(s) in RCA: 21] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/27/2008] [Revised: 12/30/2008] [Accepted: 12/31/2008] [Indexed: 11/27/2022]
Abstract
PURPOSE To conduct longitudinal, intrapatient comparisons of aspherical and spherical silicone intraocular lenses (IOL) of the same material and platform in patients undergoing bilateral cataract surgery. DESIGN Prospective, randomized study. METHODS Sixty-two eyes of 31 patients were randomized to receive a silicone aspherical IOL (Tecnis Z9000; AMO Inc, Santa Ana, California, USA) in 1 eye and a silicone spherical IOL (CeeOn 911A; AMO Inc) in the other eye. Best spectacle-corrected visual acuity (BSCVA); corneal and ocular wavefront aberrations; contrast sensitivity under photopic (180 lux), intermediate (75 lux), and scotopic (15 lux) illumination; amount of IOL decentration and tilt; and degree of posterior capsular opacification were measured at 1, 3, 6, and 12 months after surgery. All-distance visual acuity (VA) was measured 3 months after surgery. RESULTS There were no significant differences between IOLs with regard to BSCVA, amount of IOL decentration and tilt, degree of posterior capsule opacification, and all-distance VA at any point after surgery. Regarding corneal wavefront aberrations, there was no difference in third- and fourth-order root mean square (RMS). In ocular wavefront aberrations, aspherical IOLs showed significantly lower fourth-order RMS (P < .001) than spherical IOLs throughout the study, but not in third-order RMS. Contrast sensitivity under photopic and mesopic conditions was not different between IOLs, but contrast sensitivity under scotopic conditions was significantly better with aspherical IOLs than with spherical IOLs (P < .01) at all measurement points. CONCLUSIONS The silicone aspherical IOL (Tecnis Z9000; AMO Inc) significantly reduced ocular spherical aberration and improved scotopic contrast sensitivity, and these results were consistent through the 1-year follow-up.
Collapse
|
12
|
Intraindividual Comparison of Aspherical and Spherical Intraocular Lenses of Same Material and Platform. Ophthalmology 2009; 116:896-901. [DOI: 10.1016/j.ophtha.2008.11.022] [Citation(s) in RCA: 34] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/27/2008] [Revised: 11/20/2008] [Accepted: 11/24/2008] [Indexed: 11/22/2022] Open
|
13
|
|
14
|
Menapace R. [After-cataract following intraocular lens implantation. Part I. Genesis and prevention by optimizing conventional lens implants and surgical techniques]. Ophthalmologe 2007; 104:253-62; quiz 263-4. [PMID: 17323043 DOI: 10.1007/s00347-007-1492-2] [Citation(s) in RCA: 8] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/23/2022]
Abstract
After-cataract is the most common complication in cataract surgery. Implementing a sharp posterior optic edge has, together with improved cortical aspiration, drastically reduced its rate. The impact of optic design and material has been systematically studied in detail in Vienna in a series of prospectively randomized intra-individual comparison studies using objective evaluation methods. Circular rhexis-optic overlap is essential for the durability of the posterior sharp optic edge barrier effect. Using haptics with a capsular bag design and a slim junction to the optic enhanced it further. The use of fibrosis-inducing optic materials has been shown to prolong the barrier effect, which was decreased after anterior capsule polishing. Although the incidence of clinically significant after-cataract has been significantly reduced by these conventional measures, it still cannot be completely avoided.
Collapse
Affiliation(s)
- R Menapace
- Universitätsklinik für Augenheilkunde und Optometrie, AKH-Wien, Währinger Gürtel 18-20, 1090 Wien, Osterreich.
| |
Collapse
|
15
|
Miyata K, Kato S, Nejima R, Miyai T, Honbo M, Ohtani S. Influences of optic edge design on posterior capsule opacification and anterior capsule contraction. ACTA ACUST UNITED AC 2006; 85:99-102. [PMID: 17244219 DOI: 10.1111/j.1600-0420.2006.00758.x] [Citation(s) in RCA: 10] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/27/2022]
Abstract
PURPOSE To investigate the influence of optic edge design on posterior capsule opacification (PCO) and anterior capsule contraction (ACC). METHODS A total of 43 eyes of 43 patients scheduled to undergo cataract surgery were included in this study. Patients received either a Sensor AR40 intraocular lens (IOL) or a Sensor AR40e IOL. The area of the anterior capsule opening (ACO) was determined by diaphanoscopy using the anterior eye segment analysis system EAS-1000 at 1 day, 1 week and 1, 3, 6 and 12 months postoperatively. Posterior capsule opacification was evaluated objectively in two ways, using either the EAS-1000 or POCOman. RESULTS There was no significant difference between the two groups in either ACO area or percentage reduction of ACO area at any time-point after surgery. The difference in the degree of PCO 1 year after surgery was not significant when measured by either the EAS-1000 or POCOman. CONCLUSIONS A sharp IOL edge is required to prevent PCO. Sharp-edged IOLs do not appear to be a risk factor for ACC.
Collapse
|
16
|
Ebihara Y, Kato S, Oshika T, Yoshizaki M, Sugita G. Posterior capsule opacification after cataract surgery in patients with diabetes mellitus. J Cataract Refract Surg 2006; 32:1184-7. [PMID: 16857507 DOI: 10.1016/j.jcrs.2006.01.100] [Citation(s) in RCA: 50] [Impact Index Per Article: 2.8] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/27/2005] [Accepted: 01/17/2006] [Indexed: 11/21/2022]
Abstract
PURPOSE To prospectively compare the degree of posterior capsule opacification (PCO) after cataract surgery in patients with and without diabetes mellitus. SETTING Sugita Eye Hospital, Nagoya, Japan. METHODS Forty-two eyes of 42 consecutive diabetes mellitus patients (DM group) and 42 eyes of 42 non-DM patients (control group) scheduled to have cataract surgery were enrolled. The PCO value was determined using the posterior capsule opacification (POCO) system 3, 6, and 12 months after surgery. RESULTS Posterior capsule opacification values 3 months after surgery did not differ significantly between the 2 groups (P>.05). At 6 and 12 months, the PCO values of the DM group were significantly higher than those of the control group (P = .002 and P = .03, respectively). CONCLUSION Diabetic patients had significantly more severe PCO after cataract surgery than nondiabetic patients.
Collapse
Affiliation(s)
- Yoko Ebihara
- Department of Ophthalmology, Shiga Medical College, Ohtsu, Japan
| | | | | | | | | |
Collapse
|
17
|
Fan DSP, Yip WWK, Yu CBO, Rao SK, Lam DSC. Updates on the Surgical Management of Paediatric Cataract with Primary Intraocular Lens Implantation. ANNALS OF THE ACADEMY OF MEDICINE, SINGAPORE 2006. [DOI: 10.47102/annals-acadmedsg.v35n8p564] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 03/09/2023]
Abstract
With the advent of modern surgical techniques, paediatric cataract has become much more manageable. Intraocular lens (IOL) implantation is the standard of care for patients over the age of 2 years. The use of IOL in young infants is still controversial. In addition, there are still unresolved issues, such as the minimum age at which IOL can be safely implanted, IOL power selection and IOL power calculation. The current trends in the management of the above challenges are discussed. Although numerous reports on the prevention and management of posterior capsule opacification have been published, there are ongoing intensive debates and research. Long-term postoperative complications like glaucoma and rhegmatogenous retinal detachment are problems that cannot be overemphasised and these issues are also reviewed.
Key words: Congenital cataract, Intraocular lens, Posterior capsule opacification
Collapse
Affiliation(s)
| | - Wilson WK Yip
- The Chinese University of Hong Kong, Kowloon, Hong Kong
| | | | | | - Dennis SC Lam
- The Chinese University of Hong Kong, Kowloon, Hong Kong
| |
Collapse
|
18
|
Pahor D, Gracner B, Gracner T, Pahor A. [Posterior capsule opacification after phacoemulsification in patients with rheumatoid arthritis]. Wien Klin Wochenschr 2006; 118 Suppl 2:38-42. [PMID: 16817042 DOI: 10.1007/s00508-006-0545-x] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/24/2022]
Abstract
PURPOSE To assess the posterior capsule opacification (PCO) rate after phacoemulsification with polyacrylic intraocular lens (IOL) implantation in patients with rheumatoid arthritis (RA) compared with the controls, and to assess whether preoperative activity of RA is associated with a higher incidence of PCO. METHODS 24 eyes of 20 RA patients operated in a period of 4 years were included in our study. A control group of 20 eyes from 20 health subjects were also included in our study. All procedures were performed by a single surgeon with the same surgical technique and postoperative medication. RESULTS One year postoperatively in two eyes (8.3%) of RA-patients lens epithelial cells (LEC) migration of grade 1 was observed, in controls also in two eyes (10%). No correlation was observed between age, duration of RA or preoperative activity of RA and the PCO rate. CONCLUSION Following acrylic IOL implantation, the PCO rate one year after surgery was 8.3% in RA patients and 10% in controls. RA patients present no higher risk for PCO development than controls.
Collapse
Affiliation(s)
- Dusica Pahor
- Augenabteilung, Lehrkrankenhaus Maribor, Ljubljanska ulica 5, 2000 Maribor, Slovenia.
| | | | | | | |
Collapse
|
19
|
Nejima R, Miyai T, Kataoka Y, Miyata K, Honbou M, Tokunaga T, Kawana K, Kiuchi T, Oshika T. Prospective Intrapatient Comparison of 6.0-Millimeter Optic Single-Piece and 3-Piece Hydrophobic Acrylic Foldable Intraocular Lenses. Ophthalmology 2006; 113:585-90. [PMID: 16581420 DOI: 10.1016/j.ophtha.2005.10.064] [Citation(s) in RCA: 72] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/27/2005] [Revised: 10/26/2005] [Accepted: 10/27/2005] [Indexed: 11/29/2022] Open
Abstract
PURPOSE To compare postoperative performance and stability of 6.0-mm optic single- and 3-piece acrylic foldable intraocular lenses (IOLs). DESIGN Prospective, randomized, self-controlled trial. PARTICIPANTS Eighty eyes of 40 patients with bilateral senile cataracts. INTERVENTION Phacoemulsification and IOL implantation were performed. One eye of a patient was randomly assigned to the SA60AT single-piece IOL, and the contralateral eye was allocated to the MA60AC 3-piece IOL. MAIN OUTCOME MEASURES Best-corrected visual acuity (BCVA), spherical equivalent, aqueous flare intensity, anterior chamber depth, amount of IOL decentration and tilt, area of anterior capsule opening, and degree of posterior capsule opacification (PCO) were measured 2 days, 1 week, and 1, 3, 6, and 12 months after surgery. Specular microscopy was performed at 12 months postoperatively. RESULTS In the SA60AT group, the anterior chamber depth did not show significant changes after surgery (P>0.05; paired t test), and the refraction remained highly stable throughout the 1-year study period. The MA60AC group showed significant shallowing of the anterior chamber (P<0.05) and a myopic shift (P<0.05) up to 1 month after surgery. There were no significant differences between the 2 groups (P>0.05) in BCVA, aqueous flare intensity, the amount of IOL decentration, IOL tilt, area of anterior capsule opening, and degree of PCO throughout the 12-month follow-up period. CONCLUSIONS Both the SA60AT single-piece and MA60AC 3-piece lenses showed a minimum amount of decentration, tilt, anterior capsule contraction, and PCO. Although the MA60AC showed significant forward shift and myopic refractive changes after surgery, the SA60AT displayed little axial movement associated with highly stable refraction after surgery. This feature of the SA60AT should facilitate earlier spectacle prescription and quicker visual/social rehabilitation of patients after cataract surgery.
Collapse
Affiliation(s)
- Ryohei Nejima
- Meiwakai Medical Foundation, Miyata Eye Hospital, Miyazaki, Japan
| | | | | | | | | | | | | | | | | |
Collapse
|
20
|
Buehl W, Sacu S, Findl O. Association between intensity of posterior capsule opacification and contrast sensitivity. Am J Ophthalmol 2005; 140:927-30. [PMID: 16310479 DOI: 10.1016/j.ajo.2005.05.022] [Citation(s) in RCA: 34] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/04/2005] [Revised: 05/09/2005] [Accepted: 05/09/2005] [Indexed: 11/28/2022]
Abstract
PURPOSE To investigate the correlation between change in contrast sensitivity (CS) and difference in objective posterior capsule opacification (PCO) score before and after Nd:YAG laser capsulotomy. DESIGN Prospective interventional case series. METHODS CS (Functional Acuity Contrast Test, or FACT, chart), distance visual acuity (Early Treatment Diabetic Retinopathy Study [ETDRS] chart), and pupil size of 30 pseudophakic eyes with PCO of varying intensity were measured before and after capsulotomy. Digital retroillumination images were taken, and the area corresponding to the pupil size was evaluated with an automated PCO analysis program known as AQUA. RESULTS The correlation between change in PCO score and change in CS was highest (r = 0.85) for row B on the FACT chart and lowest (r = 0.09) for row E. The correlation with change in ETDRS visual acuity was 0.57. CONCLUSIONS Objective PCO assessment by an automated image analysis system correlates well with PCO-induced loss of CS and is therefore an appropriate method for clinical studies on the development and prevention of PCO.
Collapse
Affiliation(s)
- Wolf Buehl
- Department of Ophthalmology, Medical University of Vienna, Vienna, Austria
| | | | | |
Collapse
|
21
|
Sawa M, Ohji M, Kusaka S, Sakaguchi H, Gomi F, Saito Y, Tano Y. Nonvitrectomizing vitreous surgery for epiretinal membrane long-term follow-up. Ophthalmology 2005; 112:1402-8. [PMID: 15953642 DOI: 10.1016/j.ophtha.2005.02.014] [Citation(s) in RCA: 47] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/07/2005] [Accepted: 02/12/2005] [Indexed: 11/15/2022] Open
Abstract
PURPOSE To report the long-term follow-up results of nonvitrectomizing vitreous surgery for idiopathic epiretinal membrane (ERM). DESIGN Nonrandomized comparative case series. PARTICIPANTS Thirty patients were followed up for at least 5 years after nonvitrectomizing vitreous surgery. INTERVENTION Epiretinal membranes were peeled without infusion of balanced salt solution and removal of the vitreous. The data from the fellow eye was the control data. MAIN OUTCOME MEASURES We examined the visual acuities (VAs), objective refractions, and slit-lamp and Scheimpflug photographs from the preoperative and the final examinations of both eyes. Quantitative assessment of the progression of nuclear sclerosis was performed by densitometry analysis using Scheimpflug photography. The recurrence rate of ERM was determined. RESULTS The follow-up periods ranged from 60 to 102 months (mean+/-standard deviation, 72.2+/-11.0 months). The patient ages ranged from 52 to 76 years (68.8+/-6.3 years). The final VA improved or stabilized within 2 lines in 29 of 30 eyes (96.7%). No unilateral progression of nuclear sclerosis occurred in any cases. The mean preoperative and postoperative refractions without additional surgery were -0.4+/-2.9 diopters (D) and -0.2+/-3.0 D in the operated eyes, respectively, and -0.2+/-2.5 D and 0.1+/-2.4 D, respectively, in the unoperated fellow eyes. The mean differences in the refractive error between both eyes (operated eye data minus fellow eye data) were -0.2+/-0.7 D before surgery and -0.3+/-0.8 D after surgery (P = 0.319, paired t test). The mean preoperative and postoperative nuclear densities in 16 patients were 69+/-14 nuclear density units (NDUs) and 76+/-12 NDUs in the operated eyes and 71+/-14 NDUs and 78+/-14 NDUs in the fellow eyes, respectively. The mean preoperative and postoperative differences in nuclear densities in both eyes were -2+/-2 NDUs and -2+/-5 NDUs, respectively (P = 0.836, paired t test). The ERM recurred in 10 eyes (33%), and 3 eyes underwent conventional vitrectomy combined with cataract surgery. CONCLUSIONS Unilateral nuclear sclerosis did not progress for at least 5 years after nonvitrectomizing vitreous surgery. The recurrence rate of ERM appeared to be higher than that after conventional vitreous surgery.
Collapse
Affiliation(s)
- Miki Sawa
- Department of Ophthalmology, Osaka University Medical School, Suita, Osaka, Japan.
| | | | | | | | | | | | | |
Collapse
|
22
|
Buehl W, Sacu S, Findl O. Association between intensity of posterior capsule opacification and visual acuity. J Cataract Refract Surg 2005; 31:543-7. [PMID: 15811742 DOI: 10.1016/j.jcrs.2004.05.060] [Citation(s) in RCA: 21] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Accepted: 05/07/2004] [Indexed: 10/25/2022]
Abstract
PURPOSE To investigate the correlation between the change in visual acuity and the difference in objective posterior capsule opacification (PCO) scores before and after neodymium:YAG (Nd:YAG) laser capsulotomy. SETTING Department of Ophthalmology, Medical University of Vienna, Vienna, Austria. METHODS Forty pseudophakic eyes of 35 patients with PCO of varying intensity were examined before and after Nd:YAG laser capsulotomy. Visual acuity was determined using the Early Treatment Diabetic Retinopathy Study (ETDRS) chart at 4 m and the Holladay reading chart at 40 cm. The pupil diameter under reading conditions was measured each time. Digital retroillumination images of the posterior capsule were taken, and the corresponding area inside the pupil was evaluated using the Automated Quantification of After-Cataract (AQUA) automated PCO analysis program. The change in visual acuity and difference between PCO scores before and after Nd:YAG laser capsulotomy were calculated for all eyes. RESULTS The mean AQUA score (scale 0 to 10) was 3.56 before and 0.13 after Nd:YAG laser capsulotomy. The mean ETDRS visual acuity score (logMAR scale) was 0.28 and -0.07, respectively. The correlation coefficient between the differences in PCO score and distance visual acuity was 0.61 and near visual acuity, 0.62. CONCLUSIONS The objective PCO score obtained by an automated image-analysis program correlates well with the PCO-induced decrease in visual acuity when the central area (inside the pupillary aperture) of the posterior lens capsule was evaluated. Objective PCO assessment by automated image-analysis systems is, therefore, a valuable and clinically relevant method for clinical studies of the development and prevention of PCO.
Collapse
Affiliation(s)
- Wolf Buehl
- Department of Ophthalmology, Medical University of Vienna, Austria
| | | | | |
Collapse
|
23
|
Sacu S, Findl O, Linnola RJ. Optical coherence tomography assessment of capsule closure after cataract surgery. J Cataract Refract Surg 2005; 31:330-6. [PMID: 15767154 DOI: 10.1016/j.jcrs.2004.04.057] [Citation(s) in RCA: 24] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Accepted: 04/29/2004] [Indexed: 10/25/2022]
Abstract
PURPOSE To develop a technique for documenting and quantifying capsule bend formation in pseudophakic eyes, evaluate when the anterior and posterior lens capsules become completely apposed to the optic, and determine how soon a capsule bend is created at the optic edge of an intraocular lens (IOL) after cataract surgery. SETTING Medical University of Vienna, Department of Ophthalmology, Vienna, Austria. METHODS This prospective study comprised 33 eyes of 33 patients with age-related cataract who were scheduled to have cataract surgery. All eyes had phacoemulsification with implantation of 1 of 3 types of open-loop IOLs: 1-piece acrylic (SA60AT, Alcon), 3-piece acrylic (AcrySof MA60BM, Alcon), or 3-piece silicone (911A, AMO). Each group included 11 eyes. One and 3 days and 1, 2, 3, and 4 weeks after surgery, contact between the lens capsule and IOL optic as well as capsule bend formation were evaluated using optical coherence tomography (OCT). The postoperative times at which the capsule came into contact with the IOL optic and when the capsule bend formed were determined. RESULTS One day postoperatively, the mean distance between the anterior capsule and the IOL was 197 microm in the 1-piece acrylic IOL group, 161 microm in the 3-piece acrylic IOL group, and 220 microm in the 3-piece silicone IOL group. The posterior capsule was in contact with the IOL on the same day or earlier than the anterior capsule in 28 patients (85%). Postoperatively, the capsule bend formed at a mean of 10 days in the 1-piece acrylic group, 13 days in the 3-piece acrylic group, and 15 days in the 3-piece silicone group. The short-term reproducibility of the OCT technique was excellent (r = 0.99). CONCLUSIONS Optical coherence tomography produced cross-sectional tomograms of capsule-IOL contact in the early postoperative period. There was no significant difference in the time to capsule bend formation between the 3 IOLs. However, capsule bend formation at the optic edge occurred earlier with the 1-piece acrylic IOL than with the 3-piece silicone IOL.
Collapse
Affiliation(s)
- Stefan Sacu
- Department of Ophthalmology, Medical University of Vienna, Vienna, Austria
| | | | | |
Collapse
|
24
|
Hayashi K, Hayashi H. Limitation of Scheimpflug videophotography system in quantifying posterior capsule opacification after intraocular lens implantation. Am J Ophthalmol 2004; 138:696; author reply 696-7. [PMID: 15488836 DOI: 10.1016/j.ajo.2004.06.004] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/26/2022]
|
25
|
Bender L, Spalton DJ, Uyanonvara B, Boyce J, Heatley C, Jose R, Khan J. POCOman. J Cataract Refract Surg 2004; 30:2058-63. [PMID: 15474814 DOI: 10.1016/j.jcrs.2004.05.010] [Citation(s) in RCA: 55] [Impact Index Per Article: 2.8] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Accepted: 02/17/2004] [Indexed: 11/18/2022]
Abstract
PURPOSE To describe a new method of measuring posterior capsule opacification (PCO) and intraocular lens (IOL) rotation and report the validation of the method. SETTING Ophthalmology Department, St. Thomas' Hospital, and Medical Imaging, Department of Physics, King's College, London, United Kingdom. METHOD A new interactive software program, POCOman, was developed for the semiobjective assessment of PCO. Digital images of the posterior capsule, which can be acquired by any technique, are analyzed by the observer to determine the percentage area of PCO and assign a severity score. The system was validated by comparing it to clinical slitlamp evaluation of PCO and automated POCO system analysis using a library of 100 images taken from archives. The software also measures sequential IOL rotation for the evaluation of toric IOLs. RESULTS An image could be analyzed in approximately 2 minutes. The results of the POCOman system correlated well with the results of the automated POCO system and clinical evaluation. CONCLUSIONS The POCOman is an effective, user-friendly system for quantifying PCO. It can be obtained for free and has advantages over other methods.
Collapse
Affiliation(s)
- Lloyd Bender
- Department of Ophthalmology, St. Thomas' Hospital, London, United Kingdom.
| | | | | | | | | | | | | |
Collapse
|
26
|
Hayashi Y, Kato S, Fukushima H, Numaga J, Kaiya T, Tamaki Y, Oshika T. Relationship between anterior capsule contraction and posterior capsule opacification after cataract surgery in patients with diabetes mellitus. J Cataract Refract Surg 2004; 30:1517-20. [PMID: 15210231 DOI: 10.1016/j.jcrs.2003.11.045] [Citation(s) in RCA: 18] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Accepted: 11/25/2003] [Indexed: 01/10/2023]
Abstract
PURPOSE To prospectively assess the relationship between contraction of the anterior capsule opening and posterior capsule opacification (PCO) after cataract surgery in patients with diabetes mellitus. SETTING Department of Ophthalmology, University of Tokyo School of Medicine, Tokyo, Kaiya Eye Clinic, Hamamatsu, and Department of Ophthalmology, Institute of Clinical Medicine, University of Tsukuba, Ibaragi, Japan. METHODS This study comprised 45 patients (45 eyes) with diabetes mellitus who had cataract surgery. In all eyes, the anterior capsule opening area and degree of PCO were determined by diaphanoscopy using an anterior eye segment analysis system (EAS-100, Nidek, Inc.) 1 day and 1 year postoperatively. RESULTS There was no correlation between the size of the anterior capsule opening area 1 day after surgery and the degree of PCO 1 year after surgery (Pearson correlation coefficient [r] = 0.041; P =.79). The percentage reduction in the anterior capsule opening area from 1 day to 1 year after surgery did not correlate with the degree of PCO 1 year after surgery (r = -0.08; P =.60). CONCLUSION Contraction of the anterior capsule opening and PCO after cataract surgery cannot be explained by a common mechanism.
Collapse
Affiliation(s)
- Yoshie Hayashi
- Department of Ophthalmology, University of Tokyo School of Medicine, 7-3-1 Hongo, Bunkyo-ku, Tokyo 113-0033, Japan
| | | | | | | | | | | | | |
Collapse
|
27
|
Nejima R, Miyata K, Honbou M, Tokunaga T, Tanabe T, Sato M, Oshika T. A prospective, randomised comparison of single and three piece acrylic foldable intraocular lenses. Br J Ophthalmol 2004; 88:746-9. [PMID: 15148204 PMCID: PMC1772204 DOI: 10.1136/bjo.2003.037663] [Citation(s) in RCA: 44] [Impact Index Per Article: 2.2] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/04/2022]
Abstract
AIMS To compare the postoperative performance of single and three piece acrylic foldable intraocular lenses (IOLs). METHODS 20 patients underwent bilateral cataract surgery with a single piece SA30AL IOL in one eye and a three piece MA30BA IOL in the other eye. The eyes were randomly assigned to either a single or three piece lens. The amount of IOL decentration and tilt, area of anterior capsule opening, and degree of posterior capsule opacification were measured using the Scheimpflug anterior segment analysis system (Nidek EAS-1000). Visual acuity and contrast sensitivity were examined. Measurements were performed by masked examiners before and 1 day, 1 week, 1, 3, 6, and 18 months after surgery. RESULTS There were no significant differences between the two groups (p>0.05, paired t test) in the amount of IOL decentration, IOL tilt, area of anterior capsule opening, degree of posterior capsule opacification, best corrected visual acuity, and contrast sensitivity throughout the 18 month follow up period. CONCLUSION The single and three piece acrylic foldable IOLs are equally stable in the eye after surgery.
Collapse
Affiliation(s)
- R Nejima
- Miyata Eye Hospital, Miyazaki, Japan
| | | | | | | | | | | | | |
Collapse
|
28
|
Saika S. Relationship between posterior capsule opacification and intraocular lens biocompatibility. Prog Retin Eye Res 2004; 23:283-305. [PMID: 15177204 DOI: 10.1016/j.preteyeres.2004.02.004] [Citation(s) in RCA: 69] [Impact Index Per Article: 3.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/06/2023]
Abstract
The type of healing process that occurs in response to cataract surgery and intraocular lens (IOL) implantation is dependent on a complex set of variables. Their interactions determine whether or not optical clarity is restored as a result of this procedure. In this process, wound healing entails cells undergoing either epithelial-mesenchymal transition, resulting in the generation of fibroblastic cells and accumulation of extracellular matrix, or lenticular structure formation. Such desperate cellular behaviors are regulated by the localized release of different cytokines, including transforming growth factor beta and fibroblast growth factors, which can result in post-operative capsular opacification. Other factors affecting the biological and mechanical outcome of IOL implantation are its composition, surface properties and shape.
Collapse
Affiliation(s)
- Shizuya Saika
- Department of Ophthalmology, Wakayama Medical University, 811-1 Kimiidera, Wakayama 641-0012, Japan.
| |
Collapse
|
29
|
Tanaka Y, Kato S, Miyata K, Honbo M, Nejima R, Kitano S, Amano S, Oshika T. Limitation of Scheimpflug videophotography system in quantifying posterior capsule opacification after intraocular lens implantation. Am J Ophthalmol 2004; 137:732-5. [PMID: 15059713 DOI: 10.1016/j.ajo.2003.11.011] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Accepted: 11/03/2003] [Indexed: 11/22/2022]
Abstract
PURPOSE To assess the applicability of Scheimpflug videophotography system for the quantitative comparison of posterior capsule opacification after intraocular lens (IOL) implantation of different materials. DESIGN Retrospective, nonrandomized, interventional case series. METHODS Three groups (n = 15 eyes, each) underwent cataract surgery with implantation of acrylic, silicone, or hydrogel IOL. One year after surgery, the scatter light density at the anterior IOL surface level was measured using EAS-1000. Another three groups (n = 32 eyes, each) received acrylic, silicone, or hydrogel lens. One week after surgery, the scatter light density at the posterior capsule was measured. RESULTS Scatter light density at the anterior IOL surface 1 year after implantation was 7.5 +/- 3.0 computer-compatible tape (CCT) steps in the acrylic group, 6.0 +/- 2.3 CCT steps in the silicone group, and 5.0 +/- 3.2 CCT steps in the hydrogel group; the density in the acrylic group was significantly greater than that in the hydrogel group (P =.026). Scatter light density at the posterior capsule level 1 week after surgery was 28.3 +/- 8.9 CCT steps in the acrylic group, 22.2 +/- 2.0 CCT steps in the silicone group, and 26.7 +/- 6.7 CCT steps in the hydrogel group; there was a significant difference between the acrylic and silicone groups (P =.0005) and between the silicone and hydrogel groups (P =.008). CONCLUSIONS The IOL material significantly influences the scatter light density measurements of Scheimpflug videophotography system, and thus the intensity of posterior capsule opacification quantified by this system cannot be directly compared with different optic materials.
Collapse
Affiliation(s)
- Yoshikazu Tanaka
- Department of Ophthalmology, Diabetes Center, Tokyo Women's Medical University, Tokyo, Japan
| | | | | | | | | | | | | | | |
Collapse
|
30
|
Abstract
Surgery for cataract removal has become successively refined such that posterior capsular opacification is the most common problem presenting after modern cataract extraction. Various techniques and treatments exist to manage patients with posterior capsular opacification using Nd:YAG capsulotomy. There are many possible variations in initial assessment, pre-laser treatments, laser techniques, and follow-up routines. The literature on the use of Nd:YAG laser for capsulotomy was reviewed and interpreted. This article presents the currently available knowledge in a format that allows the practitioner to tailor an evidence-based protocol for treating patients with symptomatic posterior capsule opacification.
Collapse
|
31
|
Stordahl PB, Drolsum L. A comparison of Nd:YAG capsulotomy rate in two different intraocular lenses: AcrySof and Stabibag. ACTA OPHTHALMOLOGICA SCANDINAVICA 2003; 81:326-30. [PMID: 12859257 DOI: 10.1034/j.1600-0420.2003.00091.x] [Citation(s) in RCA: 16] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/23/2022]
Abstract
PURPOSE To evaluate the incidence of posterior capsule opacification after implantation of two different intraocular lenses (IOLs), AcrySof and Stabibag, by comparing the neodymium:YAG (Nd:YAG) laser capsulotomy rates. METHODS The medical records of 596 patients (705 eyes) who underwent phacoemulsification and posterior chamber IOL implantation using either AcrySof (n = 335) or Stabibag (n = 370) IOLs during a 1-year (1999) period were reviewed. Eyes with secondary cataract, combined procedures or operative complications, such as capsule tears, were excluded from the study. The subjects' age, sex, surgeon (two surgeons), and time for Nd:YAG laser capsulotomy were recorded. RESULTS The mean follow-up was 23 months in both IOL groups. There were no statistically significant differences within the two IOL groups regarding sex distribution or surgeon. The mean age in the AcrySof group was 77.0 years compared to 79.2 years in the Stabibag group (p = 0.001). Nd:YAG laser capsulotomy was performed in 7.6% of patients in the Stabibag group compared to 2.7% in the AcrySof group (i.e. at a significantly higher rate) (p = 0.004). Survival analyses demonstrated that age and type of IOL were the only independent predictors of the incidence of capsulotomy. CONCLUSIONS This study shows that the frequency of eyes with posterior capsule opacification needing capsulotomy was significantly higher in eyes with Stabibag IOLs compared to eyes with AcrySof IOLs.
Collapse
Affiliation(s)
- Per Bjørn Stordahl
- Department of Ophthalmology, Sykehuset Vestfold HF, Half.Wilhelmsens alle 17, 3116 Tønsberg, Norway.
| | | |
Collapse
|
32
|
Nishihara H, Yaguchi S, Onishi T, Chida M, Ayaki M. Surface scattering in implanted hydrophobic intraocular lenses. J Cataract Refract Surg 2003; 29:1385-8. [PMID: 12900250 DOI: 10.1016/s0886-3350(02)01994-6] [Citation(s) in RCA: 59] [Impact Index Per Article: 2.8] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/27/2022]
Abstract
PURPOSE To describe surface scattering, a new phenomenon in polyacrylic intraocular lenses (IOLs), and discuss the possible cause of this finding. SETTING Showa University, Fujigaoka Hospital, Yokohama, Kanagawa, Japan. METHODS This observational case series involved 40 patients who received the AcrySof(R) IOL (Alcon Laboratories, Inc.) as part of a clinical trial in 1991. Four patients (5 eyes) were evaluated. Thirty-three patients had the same surgery in 1999, and the findings in these patients were compared with those in the earlier patients. Lens surface scattering was evaluated by area densitometry using Scheimpflug photography. No statistical analysis was done because of the small sample size. RESULTS The 5 IOLs implanted in 1991 showed various degrees of surface scattering. The degree of scattering was greater than that in the 1999 group. There was no degradation in visual performance and no manifestation of intraocular inflammation or other adverse effect from the IOLs in either group. Attempts to remove foreign material on the IOL using the neodymium:YAG (Nd:YAG) laser were unsuccessful. CONCLUSIONS The surface scattering did not appear to be due to deposition of foreign material on the IOL surface. Densitometry and the results of Nd:YAG laser treatment suggest that the changes occurred in the near-surface layer. Phase separation of water near the IOL surface in the inherently hydrophobic material may explain the phenomenon. Newer AcrySof IOLs appear to have less surface scattering.
Collapse
Affiliation(s)
- Hitoshi Nishihara
- Department of Ophthalmology, Showa University Fujigaoka Hospital, Yokohama, Kanagawa, Japan.
| | | | | | | | | |
Collapse
|
33
|
Tsuchiya T, Ayaki M, Onishi T, Kageyama T, Yaguchi S. Three-year prospective randomized study of incidence of posterior capsule opacification in eyes treated with topical diclofenac and betamethasone. Ophthalmic Res 2003; 35:67-70. [PMID: 12646745 DOI: 10.1159/000069127] [Citation(s) in RCA: 17] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/29/2002] [Indexed: 11/19/2022]
Abstract
PURPOSE To investigate the incidence of posterior capsule opacification (PCO) in eyes treated with diclofenac sodium (DFNa) and betamethasone phosphate (BMS) ophthalmic solutions. METHODS A total of 200 eyes with silicone intraocular lens implantation were treated with topical agents for 3 months postoperatively. Twenty-six cases of the DFNa group and 34 of the BMS group met the criteria, and the severity of PCO was evaluated after 3 years. RESULTS The results of axial densitometry by Scheimpflug photography were 27.8 computer-compatible tapes (CCT) in the DFNa-treated group and 32.6 CCT in the BMS-treated group (p = 0.1539). Posterior capsulotomy was performed in 11.5% of the DFNa group and 17.6% of the BMS group (p = 0.8375). The photographic grading of PCO showed no difference. CONCLUSION The incidence of PCO in eyes treated with DFNa appears to be equal to that after BMS treatment.
Collapse
Affiliation(s)
- Tadaharu Tsuchiya
- Department of Ophthalmology, Fujigaoka Hospital, Showa University School of Medicine, Yokohama, Japan
| | | | | | | | | |
Collapse
|
34
|
Aslam TM, Dhillon B, Werghi N, Taguri A, Wadood A. Systems of analysis of posterior capsule opacification. Br J Ophthalmol 2002; 86:1181-6. [PMID: 12234903 PMCID: PMC1771330 DOI: 10.1136/bjo.86.10.1181] [Citation(s) in RCA: 23] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/03/2022]
Abstract
This paper demonstrates the wide variety of systems for the analysis of posterior capsular opacification (PCO). No single system has been proved to be a gold standard and it is difficult to comment on the advantages of one system over another with the limited current knowledge on the effects of PCO on vision. There are few studies that actually compare the different systems of analysis. Researchers must ensure that the systems they use for PCO analysis are objective and must give maximum consideration to ensuring potential systematic errors are reduced to a minimum. Further research is required into how the various types and locations of PCO affect vision and how well different systems of analysis perform.
Collapse
Affiliation(s)
- T M Aslam
- Eye Pavilion, Edinburgh, UK Department of Computing, Glasgow University, UK.
| | | | | | | | | |
Collapse
|
35
|
Schmidbauer JM, Vargas LG, Apple DJ, Escobar-Gomez M, Izak A, Arthur SN, Golescu A, Peng Q. Evaluation of neodymium:yttrium-aluminum-garnet capsulotomies in eyes implanted with AcrySof intraocular lenses. Ophthalmology 2002; 109:1421-6. [PMID: 12153790 DOI: 10.1016/s0161-6420(02)01116-8] [Citation(s) in RCA: 44] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/28/2022] Open
Abstract
PURPOSE As of December 31, 2000, the neodymium:yttrium-aluminum-garnet (Nd:YAG) laser posterior capsulotomy rate for the Alcon AcrySof intraocular lens (IOL) as measured in our database was 3.3%. This was the lowest of any IOL model used in the United States. Only 12 of 361 cases required treatment. We analyzed possible surgical reasons that may have been responsible for the posterior capsule opacification (PCO) in this small group. Special attention was given to the three surgical factors that we had previously identified as being important for PCO reduction: (1) quality of cortical clean up, (2) type of haptic fixation, and (3) continuous curvilinear capsulorhexis (CCC) size and shape. DESIGN Comparative autopsy tissue analysis. PARTICIPANTS Three hundred sixty-one human eyes obtained postmortem with Alcon AcrySof IOLs, accessioned between January 1995 and December 2000 from Lions Eye Banks. METHODS The eyes were evaluated by the Miyake-Apple posterior photographic technique. MAIN OUTCOME MEASURES The area and intensity of Soemmering's ring and type of fixation were studied in 361 eyes. The size and shape of the CCC and relation of the CCC edge to the IOL's optic rim were analyzed in 168 eyes. RESULTS The amount of Soemmering's ring formation was significantly larger in the group of IOLs requiring Nd:YAG capsulotomy (Nd:YAG group). The not in-the-bag fixated IOLs required more Nd:YAG capsulotomies. Although the trend was clear, the number of specimens was not large enough to acquire statistical significance. The Nd:YAG group showed a highly significant difference compared with the No Nd:YAG group with regard to the amount of clock hours of the CCC edge on the optic rim's surface (P < 0.001). Mean CCC diameters were significantly larger in the Nd:YAG group (P < 0.05). CONCLUSIONS The amount of Soemmering's ring correlates with the quality of cortical clean up. Cells within the Soemmering's ring are the direct precursors of PCO. This study confirms our previous laboratory studies and the clinical assumption that the incidence of PCO and thus the need for Nd:YAG capsulotomy is correlated with the cortical clean up. A second clinical assumption, that poor IOL fixation increases the risk of PCO, is also strongly suggested in this study. This study also verifies the relation of the CCC to PCO and the Nd:YAG laser, namely that a relatively small CCC without tears is best to prevent this complication. Use of a high-quality IOL combined with diligent attention to these three surgical factors should lower further the incidence of PCO.
Collapse
Affiliation(s)
- Josef M Schmidbauer
- Center for Research on Ocular Therapeutics and Biodevices, Storm Eye Institute, Department of Ophthalmology, Medical University of South Carolina, Charleston 29425-5536, USA
| | | | | | | | | | | | | | | |
Collapse
|
36
|
Hayashi K, Hayashi H, Nakao F, Hayashi F. Posterior capsule opacification after cataract surgery in patients with diabetes mellitus. Am J Ophthalmol 2002; 134:10-6. [PMID: 12095802 DOI: 10.1016/s0002-9394(02)01461-7] [Citation(s) in RCA: 57] [Impact Index Per Article: 2.6] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/22/2022]
Abstract
PURPOSE To examine the degree of posterior capsule opacification (PCO) after cataract surgery in patients with diabetes and in nondiabetic age-matched control patients. DESIGN Case-control study. METHODS The PCO density value in 100 consecutive diabetic patients and in 100 nondiabetic age-matched control patients who underwent cataract surgery was measured using a Scheimpflug videophotography system at 1 week and at 3, 6, 12, 18, 24, 30, and 36 months after surgery. The incidence of neodymium:yttrium-aluminum-garnet (Nd:YAG) laser posterior capsulotomy was also evaluated. Furthermore, the stage of diabetic retinopathy and systemic condition of the diabetes were correlated with the degree of PCO. RESULTS No significant difference between the two groups was observed in the mean value of the PCO for up to 12 months after cataract surgery. However, at 18 months and later, the PCO value in the diabetic group increased significantly and was significantly greater than in the control group. Kaplan-Meier survival curves showed that diabetic patients were significantly more likely to require Nd:YAG capsulotomy than control patients (P =.0139, Mantel-Cox log rank test). Among the diabetic patients, there was no significant correlation of PCO value with the stage of retinopathy. Furthermore, type of treatment, duration of diabetes, and hemoglobin A(1C) did not correlate with the PCO value. CONCLUSIONS Diabetic patients developed significantly greater PCO after cataract surgery than did nondiabetic patients, but among the diabetics, the stage of diabetic retinopathy and systemic status of the diabetes did not correlate with the degree of PCO.
Collapse
|
37
|
Aasuri MK, Shah U, Veenashree MP, Deshpande P. Performance of a truncated-edged silicone foldable intraocular lens in Indian eyes. J Cataract Refract Surg 2002; 28:1135-40. [PMID: 12106721 DOI: 10.1016/s0886-3350(01)01254-8] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/23/2022]
Abstract
PURPOSE To study the role of truncated-edged silicone foldable intraocular lenses (IOLs) in preventing posterior capsule opacification (PCO) in Indian eyes. SETTING Cornea and Anterior Segment Service, L.V. Prasad Eye Institute, Hyderabad, India. METHODS This prospective study evaluated 39 Indian patients (39 eyes) with a mean age of 55.4 years who had uneventful implantation of the CeeOn Edge 911A IOL (Pharmacia). All IOLs were placed in the bag. Except in 4 patients, the capsulorhexis margin overlapped 360 degrees on the IOL optic periphery. The mean follow-up was 10.9 months (range 6.5 to 13.0 months); 32 patients were followed for 1 year. RESULTS Intraoperatively, posterior capsule fibrosis was noted in 7 patients. Diffuse haze was noted in the IOL optic in 1 patient. Clinically significant PCO did not occur in any case. One patient had clinically nonsignificant (grade 1) PCO at the 6- and 12-month follow-up visits. Although epithelial pearl accumulation (Soemmering's ring) was seen beyond the edge of the IOL in the 32 patients followed for 1 year, the epithelial pearls were central only in the patient with grade 1 PCO. Significant cell deposits were noted in 1 patient who had fibrinous uveitis at the 1-week postoperative visit; both resolved by 1 month. All eyes achieved a best corrected visual acuity of 20/30 or better. CONCLUSIONS The CeeOn Edge 911A IOL was well tolerated in Indian eyes, and the posterior capsule remained clear. Larger patient groups with a longer follow-up will provide more useful information.
Collapse
Affiliation(s)
- Murali K Aasuri
- Cornea and Anterior Segment Service, L.V. Prasad Eye Institute, Hyderabad, India.
| | | | | | | |
Collapse
|
38
|
Buehl W, Findl O, Menapace R, Georgopoulos M, Rainer G, Wirtitsch M, Siegl H, Pinz A. Reproducibility of standardized retroillumination photography for quantification of posterior capsule opacification. J Cataract Refract Surg 2002; 28:265-70. [PMID: 11821208 DOI: 10.1016/s0886-3350(01)01228-7] [Citation(s) in RCA: 61] [Impact Index Per Article: 2.8] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/17/2022]
Abstract
PURPOSE To determine the short-term reproducibility of standardized digital retroillumination images of regeneratory posterior capsule opacification (PCO) using the photographic setup at 1 institution. SETTING Department of Ophthalmology, University of Vienna, Vienna, Austria. METHODS In this prospective study, 60 retroillumination images of 30 eyes with varying degrees of PCO and different types of intraocular lenses were acquired with a standardized digital coaxial retroillumination system. Two images were taken per eye with a 1-minute interval between images. Ten other eyes were photographed in the same way but with a 5-day interval between the 2 images. All images were evaluated with a fully automated, objective PCO analysis software in which the PCO score was from 0 to 100. The 2 results (A, B) in each eye were compared, and the differences were calculated. RESULTS There was a high correlation between the A and B results (r = 0.99). The mean absolute difference was 3.7%. The repeatability coefficient was 8.8%. CONCLUSION Digital coaxial retroillumination photography provided quick acquisition of regeneratory PCO images. It provided excellent image quality and high reproducibility. The technique forms a good basis for automated quantification of PCO with new software systems.
Collapse
Affiliation(s)
- Wolf Buehl
- Department of Ophthalmology, University of Vienna, Vienna, Austria
| | | | | | | | | | | | | | | |
Collapse
|
39
|
Kurosaka D, Obasawa M, Kurosaka H, Nakamura K. Inhibition of lens epithelial cell migration by an acrylic intraocular lens in vitro. Ophthalmic Res 2002; 34:29-37. [PMID: 11834882 DOI: 10.1159/000048322] [Citation(s) in RCA: 15] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/19/2022]
Abstract
We developed a new in vitro system to evaluate the effect of intraocular lenses (IOLs) on the migration of lens epithelial cells (LECs) and determined how acrylic and other IOLs influence LEC migration using this model. In an in vitro system, porcine LECs were cultured in a cell culture chamber insert, containing a collagen membrane, for 10 days with no IOL or with various types of IOLs. Migration of LECs beneath each IOL optic was observed with an inverted-phase microscope. The cell-free areas under the IOL optic, where the LECs had not migrated, were measured. Without IOL, LECs completely covered the collagen membrane within 5 days after plating (5.0 +/- 0.0 days). Complete coverage was slowed by a silicone IOL (6.7 +/- 1.2 days, p = 0.0305). LECs cultured with acrylic or with round- or sharp-edged polymethylmethacrylate (PMMA) IOLs did not completely cover the area. Ten days after initiating cultures, the cell-free areas under IOLs with sharp edges (acrylic, 41.1 +/- 8.0%; sharp-edged PMMA, 60.9 +/- 39.0%) were significantly larger than under IOLs with round edges (silicone, 0.0 +/- 0.0%; round-edged PMMA, 1.5 +/- 1.2%). A sharp edge may act as a barrier to LEC migration. Moreover, LEC migration under the acrylic IOL slowed after the LECs had crossed the barrier of the optic edge, perhaps due to acrylic adhesive properties. Only a few LECs reached the collagen membrane beneath the central 3 mm of the acrylic IOL. This new in vitro model was useful in evaluating the effect of various IOLs on LEC migration. Acrylic IOLs inhibited LEC migration by not only a sharp edge but also other factors, such as adhesive properties.
Collapse
Affiliation(s)
- Daijiro Kurosaka
- Department of Ophthalmology, Keio University School of Medicine, Tokyo, Japan.
| | | | | | | |
Collapse
|
40
|
Sawa M, Saito Y, Hayashi A, Kusaka S, Ohji M, Tano Y. Assessment of nuclear sclerosis after nonvitrectomizing vitreous surgery. Am J Ophthalmol 2001; 132:356-62. [PMID: 11530048 DOI: 10.1016/s0002-9394(01)01025-x] [Citation(s) in RCA: 34] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/18/2022]
Abstract
PURPOSE Nuclear sclerosis develops frequently after successful pars plana vitrectomy. We evaluated changes in the degree of nuclear sclerosis after nonvitrectomizing vitreous surgery for idiopathic epimacular proliferation. METHODS Forty-one consecutive patients (41 eyes) underwent removal of idiopathic epimacular proliferation by nonvitrectomizing vitreous surgery and were followed postoperatively for at least 12 months. Visual acuity, refractive error, slit-lamp biomicroscopy, and Scheimpflug photographs were assessed preoperatively and postoperatively to evaluate changes in the degree of lenticular opacification. Quantitative analysis of the nuclear sclerosis was performed by densitometry with Scheimpflug photographs performed on only the last 21 patients. We evaluated these measurements by comparing statistically the preoperative and postoperative difference between both eyes (operative eye minus nonoperative ocular data). RESULTS There was no significant difference in the progression of nuclear sclerosis or degree of myopic shift between the operated and fellow eyes during postoperative follow-up (mean +/- SD, 22 +/- 8 months; median, 22 months; range, 12 to 48 months). The average preoperative and postoperative refractive errors in operated eyes were 0.0 +/- 2.4 diopters and 0.1 +/- 2.5 diopters, respectively; the average difference in the refractive errors between both eyes was -0.2 +/- 0.7 diopter preoperatively and -0.2 +/- 0.9 diopter postoperatively (P =.961, paired t test). The average preoperative and postoperative nuclear density values by Scheimpflug photography in 21 operated eyes were, respectively, 72 +/- 18 nuclear density units and 75 +/- 17 nuclear density units; the average difference in nuclear density values between both eyes was -1 +/- 4 nuclear density units preoperatively and 0 +/- 6 nuclear density units postoperatively (P =.631, paired t test). CONCLUSION Progression of nuclear sclerotic cataract based on changes in refractive error and Scheimpflug photography was not observed after nonvitrectomizing vitreous surgery.
Collapse
Affiliation(s)
- M Sawa
- Department of Ophthalmology, Osaka University Medical School, 2-2 Yamadaoka, Suita, Osaka 565-0871, Japan.
| | | | | | | | | | | |
Collapse
|
41
|
Ram J, Kaushik S, Brar GS, Gupta A. Neodymium: YAG Capsulotomy Rates Following Phacoemulsification With Implantation of PMMA, Silicone, and Acrylic Intraocular Lenses. Ophthalmic Surg Lasers Imaging Retina 2001. [DOI: 10.3928/1542-8877-20010901-05] [Citation(s) in RCA: 26] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/20/2022]
|
42
|
Saika S, Miyamoto T, Ishida I, Tanaka T, Okada Y, Nagane Y, Shirai K, Ohnishi Y. Comparison of Scheimpflug images of posterior capsule opacification and histological findings in rabbits and humans. J Cataract Refract Surg 2001; 27:1088-92. [PMID: 11489581 DOI: 10.1016/s0886-3350(00)00860-9] [Citation(s) in RCA: 9] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/28/2022]
Abstract
PURPOSE To compare the posterior capsule opacification in Scheimpflug photographic images produced by an electronic anterior eye segment analysis system with the histopathological findings in rabbits and humans. SETTING Department of Ophthalmology, Wakayama Medical College, Japan. METHODS Opacified posterior capsules were photographed using the EAS-1000 system (Nidek) and were then extracted during vitreous surgery for proliferative diabetic retinopathy or proliferative vitreoretinopathy in 2 patients. In rabbits, phacoemulsification and aspiration (PEA) with intraocular lens (IOL) implantation was performed. The IOL was implanted in the bag or in the sulcus. After intervals of healing, the posterior capsule was photographed with the EAS-1000 and the animals were then killed. In both clinical and experimental specimens, the posterior capsule was processed for light microscopic histology and immunohistochemistry. RESULTS Opacified human capsules were well imaged by the EAS-1000. Histology showed that lens epithelial cells proliferated with and without an accumulation of extracellular matrix. Details such as rolling of the capsulotomy edge were seen well. Regenerated lens fibers of Soemmering's ring were seen as a mass within the capsule. In the rabbit model, Scheimpflug images accurately represented the capsules as they appeared histologically. CONCLUSION The EAS-1000 system provided faithful, relatively high-resolution images that corresponded to the histologic findings in the posterior capsules after PEA-IOL surgery in humans and rabbits.
Collapse
Affiliation(s)
- S Saika
- Department of Ophthalmology, Wakayama Medical College, 811-1 Kimiidera, Wakayama, 641-8509, Japan.
| | | | | | | | | | | | | | | |
Collapse
|
43
|
Cheng CY, Yen MY, Chen SJ, Kao SC, Hsu WM, Liu JH. Visual acuity and contrast sensitivity in different types of posterior capsule opacification. J Cataract Refract Surg 2001; 27:1055-60. [PMID: 11489575 DOI: 10.1016/s0886-3350(00)00867-1] [Citation(s) in RCA: 32] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/19/2022]
Abstract
PURPOSE To compare the visual acuity (VA) and contrast sensitivity in 2 types of posterior capsule opacification (PCO) in pseudophakic eyes before and after neodymium:YAG (Nd:YAG) capsulotomy and to evaluate vision test results after Nd:YAG capsulotomy. SETTING Department of Ophthalmology, Taipei Veterans General Hospital, National Yang-Ming University, Taipei, Taiwan. METHODS Fourteen eyes with fibrosis-type PCO and 15 eyes with Elschnig-pearl-type PCO were enrolled prospectively. Before and 1 week after Nd:YAG capsulotomy, VA and contrast sensitivity were assessed using the illiterate E version of the Bailey-Lovie chart and the Vistech VCTS 6000 chart, respectively. RESULTS Before capsulotomy, the mean logMAR acuity in the group with Elschnig-pearl-type PCO was 0.47 +/- 0.32 (SD) and in the group with fibrosis-type PCO, 0.17 +/- 0.07. The difference between the 2 groups was significant (P =.002). After capsulotomy, there was no significant between-group difference (P >.05). Before capsulotomy, the contrast sensitivity was significantly worse (P <.01) at all spatial frequencies in the group with pearl-type PCO, especially at 6 cycles per degree. After capsulotomy, there was no significant between-group difference (P >.05) at any spatial frequency. CONCLUSIONS After cataract surgery, patients with pearl-type PCO had lower VA and contrast sensitivity than those with fibrosis-type PCO. An Nd:YAG capsulotomy improved the VA and contrast sensitivity in patients with both types of PCO.
Collapse
Affiliation(s)
- C Y Cheng
- Department of Ophthalmology, Taipei Veterans General Hospital, National Yang-Ming University, 201 Sec. Shih-Pai Road, Taipei 11217, Taiwan
| | | | | | | | | | | |
Collapse
|
44
|
Hayashi K, Hayashi H, Nakao F, Hayashi F. Changes in posterior capsule opacification after poly(methyl methacrylate), silicone, and acrylic intraocular lens implantation. J Cataract Refract Surg 2001; 27:817-24. [PMID: 11408125 DOI: 10.1016/s0886-3350(01)00787-8] [Citation(s) in RCA: 82] [Impact Index Per Article: 3.6] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/15/2022]
Abstract
PURPOSE To prospectively evaluate the progression of posterior capsule opacification (PCO) after poly(methyl methacrylate) (PMMA), silicone, and acrylic intraocular lens (IOL) implantation. SETTING Hayashi Eye Hospital, Fukuoka, Japan. METHODS Three hundred eyes of 300 patients scheduled to have IOL implantation were initially randomized into 3 groups based on IOL type: PMMA, silicone, or acrylic. Of the 300 eyes, 269 completed the follow-up. The PCO density in these eyes was measured 1 week and 3, 6, 12, 18, and 24 months postoperatively using special computer software developed for the Scheimpflug videophotography system. Visual acuity and the incidence of neodymium:YAG (Nd:YAG) laser capsulotomy were also examined. RESULTS Three months postoperatively and later, the mean PCO value in the PMMA group increased significantly (P <.0001); the increase in the silicone and acrylic groups was not significant. The PCO value in the PMMA group was significantly greater than in the silicone or acrylic group (P <.0001). The PCO value in the acrylic group was slightly less than in the silicone group at 18 and 24 months, but the difference was marginal. The survival rate not requiring Nd:YAG capsulotomy was least in the PMMA group, followed by the silicone and acrylic groups in that order (P <.0001). The mean logMAR visual acuity in the PMMA group increased postoperatively and was worse than in the silicone or acrylic group. CONCLUSIONS The degree of PCO after PMMA IOL implantation progressed significantly with time, while the progression after silicone and acrylic IOL implantation was slight. Therefore, PCO in eyes with a PMMA IOL was significantly more extensive than in those with a silicone or acrylic IOL and resulted in marked impairment of visual acuity.
Collapse
Affiliation(s)
- K Hayashi
- Hayashi Eye Hospital, Fukuoka, Japan.
| | | | | | | |
Collapse
|
45
|
Apple DJ, Peng Q, Visessook N, Werner L, Pandey SK, Escobar-Gomez M, Ram J, Auffarth GU. Eradication of posterior capsule opacification: documentation of a marked decrease in Nd:YAG laser posterior capsulotomy rates noted in an analysis of 5416 pseudophakic human eyes obtained postmortem. Ophthalmology 2001; 108:505-18. [PMID: 11237905 DOI: 10.1016/s0161-6420(00)00589-3] [Citation(s) in RCA: 209] [Impact Index Per Article: 9.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/18/2023] Open
Abstract
OBJECTIVE (1) To report the neodymium:yttrium-aluminum-garnet (Nd:YAG) laser posterior capsulotomy rate (%) of eight rigid and foldable intraocular lens (IOL) designs in a series of 5416 pseudophakic human eyes obtained postmortem, accessioned in our center between January 1988 and January 2000. (2) To identify factors that are instrumental in reducing the incidence of posterior capsule opacification, (PCO, secondary cataract) and hence the need for Nd:YAG laser posterior capsulotomy. DESIGN Comparative autopsy tissue analysis. PARTICIPANTS A total of 5416 globes with posterior chamber intraocular lens (PC-IOLs) obtained postmortem received from Lions Eye Banks between 1988 and 2000. METHODS Miyake-Apple posterior photographic technique. Special reference was given to the presence or absence of Nd:YAG laser posterior capsulotomy orifice on the posterior capsule of each eye. MAIN OUTCOME MEASURES The Nd:YAG laser posterior capsulotomy rate (%) as of January 2000 was documented. In addition, the Nd:YAG laser posterior capsulotomy rate for each lens was plotted on a monthly basis for the same period, creating a computerized trend or "timeline" for each IOL style. RESULTS Relatively high Nd:YAG laser posterior capsulotomy rates ranging from 20.3% to 33.4% were noted with four relatively older designs (high incidence of implantation between 1988 and the early 1990s). Four modern foldable IOLs manufactured from silicone and acrylic materials had significantly lower Nd:YAG laser posterior capsulotomy rates ranging from 0.9% (Alcon Acrysof) to 17.1%. The difference in Nd:YAG rates among the eight IOL designs was found to be significant (P < 0.0001, chi-square test). Comparing foldable versus rigid designs, the foldable IOLs were associated with a much lower Nd:YAG laser posterior capsulotomy rate (14.1% vs. 31.1%). CONCLUSIONS By use of the six factors regarding surgical technique and IOL choice described in this article, we strongly believe that the overall incidence of PCO and hence the incidence of Nd:YAG laser posterior capsulotomy is now rapidly decreasing from rates as high as 50% in the 1980s to early 1990s. Surgical tools and IOLs are now available to bring these rates down to single digits. Careful application and use of these tools by surgeons can genuinely lead in the direction of virtual eradication of secondary cataract, the second most common cause of visual loss worldwide.
Collapse
Affiliation(s)
- D J Apple
- Center for Research on Ocular Therapeutic and Biodevices, Storm Eye Institute, Department of Ophthalmology, Medical University of South Carolina, Charleston, South Carolina 29425-2236, USA
| | | | | | | | | | | | | | | |
Collapse
|
46
|
Abstract
Posterior capsule opacification (PCO) is still the most frequent complication of cataract surgery. A variety of studies has led to a better understanding of the pathogenesis of PCO, and strategies of molecular biology have produced new therapeutic options, such as immunological techniques or gene therapeutic approaches. Surgical strategies and intra-ocular lens-dependent factors also are capable to reduce the rate of PCO. In-the-bag implantation of intra-ocular lenses with a sharp optic edge seems to be effective in inhibiting equatorial lens epithelial cell migration to the center of the posterior capsule. Several PCO documentation systems have been developed that will lead to more exact and better comparable recording of PCO rates. In the year 2000, PCO or secondary cataract is still the most frequent complication after extracapsular cataract surgery. In a 1998 meta-analysis, PCO rates of 11.8% 1 year after extracapsular cataract surgery with intraocular lens implantation, 20.7% after 3 years, and 28.4 % after 5 years have been reported. For the United States, it has been estimated that the overall expenses for treatment of PCO are only exceeded by the costs for cataract treatment itself. In the past decade, a lot of experimental and clinical studies have been performed on this topic. They have led to 1) to a better understanding of the pathogenesis of the development of anterior and posterior capsule opacification; 2) more objective and better comparable systems of documentation and analysis of PCO; and a number of 3) surgical and 4) pharmaceutical strategies to prevent PCO.
Collapse
Affiliation(s)
- E Bertelmann
- Eye Department, Charité Campus Virchow Hospital, Humboldt University Berlin, Berlin, Germany.
| | | |
Collapse
|
47
|
|
48
|
Abstract
Posterior capsule opacification (PCO) is the most common complication following primary cataract surgery. Advances in intraocular lens (IOL) designs that have reduced the amount of PCO following surgery have been made. The understanding of how the IOL design effects PCO has also advanced. Lenses that provide a mechanical barrier between it and the posterior lens capsule seem to inhibit PCO to a greater degree. Intracapsular rings are now being explored to test and enhance this barrier effect. Major advances in the elimination of lens epithelial cells at the time of surgery especially by pharmacologic means have also been made. An immunotoxin specific for human lens epithelial cells shows promise and is under latter phase clinical development.
Collapse
Affiliation(s)
- D S Clark
- Medarex, Annandale, NJ 08801-0953, USA
| |
Collapse
|
49
|
Apple DJ, Peng Q, Visessook N, Werner L, Pandey SK, Escobar-Gomez M, Ram J, Whiteside SB, Schoderbeck R, Ready EL, Guindi A. Surgical prevention of posterior capsule opacification. Part 1: Progress in eliminating this complication of cataract surgery. J Cataract Refract Surg 2000; 26:180-7. [PMID: 10683785 DOI: 10.1016/s0886-3350(99)00353-3] [Citation(s) in RCA: 120] [Impact Index Per Article: 5.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/25/2022]
Abstract
PURPOSE To evaluate over almost 2 decades the success of a component of cataract surgery that represents a critical step in reducing the incidence of posterior capsule opacification (PCO); namely, the efficacy of cortical cleanup. SETTING Center for Research on Ocular Therapeutics and Biodevices, Storm Eye Institute, Department of Ophthalmology, Medical University of South Carolina, Charleston, South Carolina, USA. METHODS Accessioned from the early 1980s to 1997, 3320 eyes obtained postmortem with posterior chamber intraocular lenses were analyzed with respect to formation of a postoperative Soemmering's ring. This anatomic lesion, the precursor of clinical PCO, represents an important and measurable indication of the quality of cortical cleanup. Its formation was documented using Miyake-Apple posterior photographic analysis. RESULTS The quality and thoroughness of cortical cleanup and overall effectiveness in eliminating retained and/or regenerating cortical cells, as measured by scoring of Soemmering's rings, showed virtually no net change since the early 1980s. The intensity of Soemmering's ring was higher in the most recent specimens than in those in the early 1980s. CONCLUSION The results indicate that renewed attention to cortical cleanup in cataract surgery is warranted for significant reduction in incidence or the elimination of PCO. More attention to the hydrodissection (cortical cleaving hydrodissection) step of the procedure is likely a practical, immediately implementable, and inexpensive remedy.
Collapse
Affiliation(s)
- D J Apple
- Department of Ophthalmology, Medical University of South Carolina, Charleston 29425-2236, USA
| | | | | | | | | | | | | | | | | | | | | |
Collapse
|
50
|
Wang MC, Woung LC. Digital retroilluminated photography to analyze posterior capsule opacification in eyes with intraocular lenses. J Cataract Refract Surg 2000; 26:56-61. [PMID: 10646147 DOI: 10.1016/s0886-3350(99)00332-6] [Citation(s) in RCA: 25] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/17/2022]
Abstract
PURPOSE To compare the formation and rates of posterior capsule opacification (PCO) in eyes with poly(methyl methacrylate) (PMMA) versus silicone intraocular lenses (IOLs) using an in vivo objective method. SETTING Taipei Municipal Yang-Ming Hospital, Taipei, Taiwan, Republic of China. METHODS This prospective study comprised 40 eyes with senile cataract receiving phacoemulsification with capsular implantation of an IOL from March to April 1997. The uneventful surgeries were performed using the stop and chop method by the same surgeon. Twenty eyes received a PMMA IOL (Pharmacia 812A) and 20, a silicone IOL (AMO SI-30NB). One year later, digital retroillumination images taken with the EAS-1000 anterior segment analysis system (Nidek) were used to analyze posterior capsule transparency over the central 3.0 and 5.0 mm optic zones and evaluate the degree of PCO over the central and peripheral zones. RESULTS Over the central 5.0 mm optic zone, mean transparency of the capsule was 87.71% +/- 11.35% (SD) in the silicone group and 79.22% +/- 21.10% in the PMMA group (P = .17). Over the central 3.0 mm optic zone, the means were 97.17% +/- 5.96% and 86.32% +/- 19.60%, respectively (P = .048). Mean opacity in the central zone was 75.18 +/- 13.22 digital opacity units (OUs) in the silicone group and 80.24 +/- 7.93 OUs in the PMMA group (P = .18). The means in the peripheral zone were 88.49 +/- 18.47 OUs and 90.35 +/- 9.98 OUs, respectively (P = .71). CONCLUSION The posterior capsule in the silicone IOL group was more transparent than in the PMMA IOL group over the central 3.0 mm optic zone after 1 year follow-up.
Collapse
Affiliation(s)
- M C Wang
- Department of Ophthalmology, Taipei Municipal Yang-Ming Hospital, Taiwan, Republic of China
| | | |
Collapse
|