1
|
Saveleva MS, Verkhovskii RA, Demina PA, Surkov YI, Anisimov RA, Prikhozhdenko ES, Pidenko PS, Serebryakova IA, Zaytsev SM, Tuchin VV, Svenskaya YI. Biodegradable calcium carbonate carriers for the topical delivery of clobetasol propionate. J Mater Chem B 2024; 12:4867-4881. [PMID: 38666451 DOI: 10.1039/d4tb00303a] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 05/23/2024]
Abstract
Inflammatory dermatoses represent a global problem with increasing prevalence and recurrence among the world population. Topical glucocorticoids (GCs) are the most commonly used anti-inflammatory drugs in dermatology due to a wide range of their therapeutic actions, which, however, have numerous local and systemic side effects. Hence, there is a growing need to create new delivery systems for GCs, ensuring the drug localization in the pathological site, thus increasing the effectiveness of therapy and lowering the risk of side effects. Here, we propose a novel topical particulate formulation for the GC clobetasol propionate (CP), based on the use of porous calcium carbonate (CaCO3) carriers in the vaterite crystalline form. The designed carriers contain a substantially higher CP amount than conventional dosage forms used in clinics (4.5% w/w vs. 0.05% w/w) and displayed a good biocompatibility and effective cellular uptake when studied in fibroblasts in vitro. Hair follicles represent an important reservoir for the GC accumulation in skin and house the targets for its action. In this study, we demonstrated successful delivery of the CP-loaded carriers (CP-CaCO3) into the hair follicles of rats in vivo using optical coherent tomography (OCT). Importantly, the OCT monitoring revealed the gradual intrafollicular degradation of the carriers within 168 h with the most abundant follicle filling occurring within the first 48 h. Biodegradability makes the proposed system especially promising when searching for new CP formulations with improved safety and release profile. Our findings evidenced the great potential of the CaCO3 carriers in improving the dermal bioavailability of this poorly water-soluble GC.
Collapse
Affiliation(s)
- Mariia S Saveleva
- Science Medical Center, Saratov State University, 410012 Saratov, Russia.
| | | | - Polina A Demina
- Science Medical Center, Saratov State University, 410012 Saratov, Russia.
| | - Yury I Surkov
- Science Medical Center, Saratov State University, 410012 Saratov, Russia.
- Institute of Physics, Saratov State University, 410012 Saratov, Russia
| | - Roman A Anisimov
- Science Medical Center, Saratov State University, 410012 Saratov, Russia.
- Institute of Physics, Saratov State University, 410012 Saratov, Russia
| | - Ekaterina S Prikhozhdenko
- Science Medical Center, Saratov State University, 410012 Saratov, Russia.
- Institute of Physics, Saratov State University, 410012 Saratov, Russia
| | - Pavel S Pidenko
- Institute of Chemistry, Saratov State University, 410012 Saratov, Russia
| | | | - Sergey M Zaytsev
- Institute of Physics, Saratov State University, 410012 Saratov, Russia
| | - Valery V Tuchin
- Science Medical Center, Saratov State University, 410012 Saratov, Russia.
- Institute of Physics, Saratov State University, 410012 Saratov, Russia
| | - Yulia I Svenskaya
- Science Medical Center, Saratov State University, 410012 Saratov, Russia.
| |
Collapse
|
2
|
Lee DH, Lim S, Kwak SS, Kim J. Advancements in Skin-Mediated Drug Delivery: Mechanisms, Techniques, and Applications. Adv Healthc Mater 2024; 13:e2302375. [PMID: 38009520 DOI: 10.1002/adhm.202302375] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/25/2023] [Revised: 10/11/2023] [Indexed: 11/29/2023]
Abstract
Skin-mediated drug delivery methods currently are receiving significant attention as a promising approach for the enhanced delivery of drugs through the skin. Skin-mediated drug delivery offers the potential to overcome the limitations of traditional drug delivery methods, including oral administration and intravenous injection. The challenges associated with drug permeation through layers of skin, which act as a major barrier, are explored, and strategies to overcome these limitations are discussed in detail. This review categorizes skin-mediated drug delivery methods based on the means of increasing drug permeation, and it provides a comprehensive overview of the mechanisms and techniques associated with these methods. In addition, recent advancements in the application of skin-mediated drug delivery are presented. The review also outlines the limitations of ongoing research and suggests future perspectives of studies regarding the skin-mediated delivery of drugs.
Collapse
Affiliation(s)
- Dong Ha Lee
- Center for Bionics of Biomedical Research Division, Korea Institute of Science and Technology, Seoul, 02792, Republic of Korea
- Department of Materials Science and Engineering, Yonsei University, Seoul, 03722, Republic of Korea
| | - Sunyoung Lim
- Center for Bionics of Biomedical Research Division, Korea Institute of Science and Technology, Seoul, 02792, Republic of Korea
- School of Biomedical Engineering, Korea University, Seoul, 02841, Republic of Korea
| | - Sung Soo Kwak
- Center for Bionics of Biomedical Research Division, Korea Institute of Science and Technology, Seoul, 02792, Republic of Korea
| | - Joohee Kim
- Center for Bionics of Biomedical Research Division, Korea Institute of Science and Technology, Seoul, 02792, Republic of Korea
| |
Collapse
|
3
|
Mahran HG. Shockwave versus ultrasound therapy in the enhancement of Aloe vera in cutaneous wound healing. J Wound Care 2023; 32:cxxxix-cxlv. [PMID: 37405969 DOI: 10.12968/jowc.2023.32.sup7a.cxxxix] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 07/07/2023]
Abstract
OBJECTIVE To investigate the healing efficacy of topical Aloe vera enhanced by shockwave or ultrasound therapy on wounds in rats and compare both effects. METHOD A total of 75 male albino rats were randomly divided into equal groups A, B, C, D and E. Under anaesthesia, a wound (6cm2) was created on the back of each rat. Group A received topical Aloe vera under occlusive dressing followed by shockwave therapy with the following parameters: 600 shocks, four pulses/second and 0.11mJ/mm2. Group B received topical Aloe vera under occlusive dressing followed by therapeutic ultrasound with the following parameters: pulsed mode, 2:8 duty cycle, 1MHz and 0.5 W/cm2. Group C received the same treatment as group A but in a reversed sequence-the shockwave therapy followed by the Aloe vera gel. Group D received the same treatment as group B but in a reversed sequence-therapeutic ultrasound followed by the Aloe vera gel. And control group E only received topical Aloe vera under occlusive dressing. Each group received three sessions per week, for two weeks. Wound extent and shrinkage rates were measured at study initiation and at the end of each week. RESULTS There were significant wound reductions in groups A and B compared to C and D, respectively, and in group A compared to group B. CONCLUSION Shockwaves and ultrasound were found to amplify the effect of the Aloe vera on the wound, and there was improved wound healing in the shockwave group A compared to the ultrasound group B.
Collapse
Affiliation(s)
- Hesham Galal Mahran
- Department of Physical Therapy for Surgery, Faculty of Physical Therapy, Cairo University, Giza, Egypt
| |
Collapse
|
4
|
Xu J, Cai H, Wu Z, Li X, Tian C, Ao Z, Niu VC, Xiao X, Jiang L, Khodoun M, Rothenberg M, Mackie K, Chen J, Lee LP, Guo F. Acoustic metamaterials-driven transdermal drug delivery for rapid and on-demand management of acute disease. Nat Commun 2023; 14:869. [PMID: 36797284 PMCID: PMC9935629 DOI: 10.1038/s41467-023-36581-2] [Citation(s) in RCA: 12] [Impact Index Per Article: 12.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/28/2022] [Accepted: 02/06/2023] [Indexed: 02/18/2023] Open
Abstract
Transdermal drug delivery provides convenient and pain-free self-administration for personalized therapy. However, challenges remain in treating acute diseases mainly due to their inability to timely administrate therapeutics and precisely regulate pharmacokinetics within a short time window. Here we report the development of active acoustic metamaterials-driven transdermal drug delivery for rapid and on-demand acute disease management. Through the integration of active acoustic metamaterials, a compact therapeutic patch is integrated for penetration of skin stratum corneum and active percutaneous transport of therapeutics with precise control of dose and rate over time. Moreover, the patch device quantitatively regulates the dosage and release kinetics of therapeutics and achieves better delivery performance in vivo than through subcutaneous injection. As a proof-of-concept application, we show our method can reverse life-threatening acute allergic reactions in a female mouse model of anaphylaxis via a multi-burst delivery of epinephrine, showing better efficacy than a fixed dosage injection of epinephrine, which is the current gold standard 'self-injectable epinephrine' strategy. This innovative method may provide a promising means to manage acute disease for personalized medicine.
Collapse
Affiliation(s)
- Junhua Xu
- Department of Intelligent Systems Engineering, Indiana University, Bloomington, IN, 47405, USA
- Biopharmaceutical Research Institute, West China Hospital, Sichuan University, Chengdu, 610041, Sichuan, China
| | - Hongwei Cai
- Department of Intelligent Systems Engineering, Indiana University, Bloomington, IN, 47405, USA
| | - Zhuhao Wu
- Department of Intelligent Systems Engineering, Indiana University, Bloomington, IN, 47405, USA
| | - Xiang Li
- Department of Intelligent Systems Engineering, Indiana University, Bloomington, IN, 47405, USA
| | - Chunhui Tian
- Department of Intelligent Systems Engineering, Indiana University, Bloomington, IN, 47405, USA
| | - Zheng Ao
- Department of Intelligent Systems Engineering, Indiana University, Bloomington, IN, 47405, USA
| | - Vivian C Niu
- Department of Intelligent Systems Engineering, Indiana University, Bloomington, IN, 47405, USA
- Bloomington High School South, Bloomington, IN, 47401, USA
| | - Xiao Xiao
- Department of Bioengineering, University of California, Los Angeles, Los Angeles, CA, 90095, USA
| | - Lei Jiang
- Department of Intelligent Systems Engineering, Indiana University, Bloomington, IN, 47405, USA
| | - Marat Khodoun
- Division of Allergy and Immunology, Cincinnati Children's Hospital Medical Center, University of Cincinnati, Cincinnati, OH, 45229, USA
| | - Marc Rothenberg
- Division of Allergy and Immunology, Cincinnati Children's Hospital Medical Center, University of Cincinnati, Cincinnati, OH, 45229, USA
| | - Ken Mackie
- Gill Center for Biomolecular Science, and Department of Psychological and Brain Sciences, Indiana University, Bloomington, IN, 47405, USA
| | - Jun Chen
- Department of Bioengineering, University of California, Los Angeles, Los Angeles, CA, 90095, USA.
| | - Luke P Lee
- Department of Medicine, Brigham and Women's Hospital, Harvard Medical School, Boston, MA, 02115, USA.
- Department of Bioengineering, Department of Electrical Engineering and Computer Science, University of California at Berkeley, Berkeley, CA, 94720, USA.
- Institute of Quantum Biophysics, Department of Biophysics, Sungkyunkwan University, Suwon, Korea.
| | - Feng Guo
- Department of Intelligent Systems Engineering, Indiana University, Bloomington, IN, 47405, USA.
| |
Collapse
|
5
|
Liao AH, Chen YC, Chen CY, Chang SC, Chuang HC, Lin DL, Chiang CP, Wang CH, Wang JK. Mechanisms of ultrasound-microbubble cavitation for inducing the permeability of human skin. J Control Release 2022; 349:388-400. [PMID: 35787912 DOI: 10.1016/j.jconrel.2022.06.056] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/16/2022] [Revised: 06/25/2022] [Accepted: 06/28/2022] [Indexed: 12/13/2022]
Abstract
We have previously reported that ultrasound (US)-mediated microbubble (MB) cavitation (US-MB) changed the permeability of the skin and significantly enhanced transdermal drug delivery (TDD) without changing the structure of the skin. In this study we found that US-MB enhanced TDD via disruption of epidermal cell-cell junctions and increased matriptase activity. Matriptase is a membrane-bound serine protease regulated by its inhibitor hepatocyte growth factor activator inhibitor-1 (HAI-1), and it is expressed in most epithelial tissues under physiologic conditions. Matriptase is expressed in mice after chronic exposure to UV radiation. This study found that US-MB can be used to monitor active matriptase, which rapidly formed the canonical 120-kDa matriptase-HAI-1 complex. These processes were observed in HaCaT human keratinocytes when matriptase activation was induced by US-MB. The results of immunoblot analysis indicated that the matriptase-HAI-1 complex can be detected from 10 min to 3 h after US-MB. Immunohistochemistry (IHC) of human skin revealed that US-MB rapidly increased the activated matriptase, which was observed in the basal layer, with this elevation lasting 3 h. After 3 h, the activated matriptase extended from the basal layer to the granular layer, and then gradually decayed from 6 to 12 h. Moreover, prostasin expression was observed in the epidermal granular layer to the spinous layer, and became more obvious in the granular layer after 3 h. Prostasin was also detected in the cytoplasm or on the cell membrane after 6 h. These results suggest that matriptase plays an important role in recovering from US-MB-induced epidermal cell-cell junction disruption within 6 h. US-MB is therefore a potentially effective method for noninvasive TDD in humans.
Collapse
Affiliation(s)
- Ai-Ho Liao
- Graduate Institute of Biomedical Engineering, National Taiwan University of Science and Technology, Taipei 10607, Taiwan; Department of Biomedical Engineering, National Defense Medical Center, Taipei 11490, Taiwan
| | - Yu-Chen Chen
- Graduate Institute of Biomedical Engineering, National Taiwan University of Science and Technology, Taipei 10607, Taiwan
| | - Chia-Yu Chen
- Graduate Institute of Biomedical Engineering, National Taiwan University of Science and Technology, Taipei 10607, Taiwan
| | - Shun-Cheng Chang
- Division of Plastic Surgery, Integrated Burn and Wound Care Center, Department of Surgery, Shuang-Ho Hospital, New Taipei City 235, Taiwan; Department of Surgery, School of Medicine, College of Medicine, Taipei Medical University, Taipei 11031, Taiwan
| | - Ho-Chiao Chuang
- Department of Mechanical Engineering, National Taipei University of Technology, Taipei 106344, Taiwan
| | - Dao-Lung Lin
- Spirit Scientific Co., Ltd. Taiwan Branch (Cayman), 12F-8, No. 99, Sec. 1, Xintai 5th Rd., Xizhi Dist., New Taipei City 221416, Taiwan
| | - Chien-Ping Chiang
- Department of Dermatology, Tri-Service General Hospital, National Defense Medical Center, Taipei 11490, Taiwan; Department of Biochemistry, National Defense Medical Center, Taipei 11490, Taiwan
| | - Chih-Hung Wang
- Graduate Institute of Medical Sciences, National Defense Medical Center, Taipei 11490, Taiwan; Department of Otolaryngology-Head and Neck Surgery, Tri-Service General Hospital, National Defense Medical Center, Taipei 11490, Taiwan.
| | - Jehng-Kang Wang
- Department of Biochemistry, National Defense Medical Center, Taipei 11490, Taiwan.
| |
Collapse
|
6
|
Mahendra Raj R, Saravanan T, Preethi P, Ezhilarasi I. Comparative evaluation of efficacy of therapeutic ultrasound and phonophoresis in myofascial pain dysfunction syndrome. JOURNAL OF INDIAN ACADEMY OF ORAL MEDICINE AND RADIOLOGY 2022. [DOI: 10.4103/jiaomr.jiaomr_100_22] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/04/2022] Open
|
7
|
ANTONESCU OR, SILISTEANU AE, RACHERIU M, SZAKÁCS J. Emotionality and Quality of Life in Patients with Musculoskeletal Disorders. BALNEO AND PRM RESEARCH JOURNAL 2021. [DOI: 10.12680/balneo.2021.448] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/16/2022] Open
Abstract
Introduction: It is well-known that musculoskeletal conditions are related with pain and anxiety. Anxiety is a complex concept that involves a transient state caused by different factors, as well as a persistent mood.
Aim: The aim of the study is to reveal the associations between the discomfort caused by some musculoskeletal disorders and the emotionality (anxiety as a trait or a state) on the one hand and, on the other hand, the level of quality of life.
Material and method: The study was cross-sectional and was performed in a period of 6 months on an outpatient basis of 174 patients with musculoskeletal disorders. Thus, we have taken into consideration 5 groups of patients, according to the presented medical condition: low back pain, law back osteoporosis, hand osteoarthritis, knee osteoarthritis, coxarthrosis. We have administered two scales to all the patients: The State Trait Anxiety Inventory (STAI) form X1 (anxiety a s a state) and form X2 (anxiety as a trait) and the Quality of Life (QOL)
Results: For patients who were diagnosed with low back pain, quality of life was 60.71% of the maximum value. Anxiety by using the S.T.A.I. form X1 at an average value was 46.5, anxiety assessed by the STAI form X2 scale, indicates an average value of 39. In the case of osteoporosis, the value of their quality of life was 90.18%. Anxiety (form X1) was 36, and anxiety (form X2) was 52. For the patients diagnosed with hip osteoarthritis, respectively with knee osteoarthritis, the quality of life were 87.5% and 77.67%, anxiety (form X1) were 41 and 48, anxiety (form X2) were 47 and 61. For patients diagnosed with hand disorders, the quality of life was 81.25%, anxiety (form X1) was 62 and anxiety (form X2) was 47.
Conclusions: It was found that in the case of the low back pain, the quality of life had the lowest value (60.71% of the maximum value). In knee osteoarthritis it was found the highest value of anxiety as a trait was 61, and the highest value of anxiety as a condition was found in osteoarthritis of the hand as 62.
Keywords: anxiety, quality of life, musculoskeletal disorders,
Collapse
Affiliation(s)
| | | | - Mihaela RACHERIU
- County Clinical Emergency Hospital, Sibiu, Romania, George Emil Palade University of Medicine, Pharmacy, Science, and Technology of Targu Mures, Faculty of Medicine, Department of Biophysics, Targu Mureș, Romania
| | - Juliánna SZAKÁCS
- George Emil Palade University of Medicine, Pharmacy, Science, and Technology of Targu Mures, Faculty of Medicine, Department of Biophysics, Targu Mureș, Romania
| |
Collapse
|
8
|
SZAKÁCS J, DUICA LC, RACHERIU M. Quality of Life and Negative Affectivity at the Patients with Stroke and Musculoskeletal Disorders. BALNEO AND PRM RESEARCH JOURNAL 2021. [DOI: 10.12680/balneo.2021.449] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/16/2022] Open
Abstract
Introduction. Stroke can be a severe debilitating medical condition due to its medical consequences. When it occurs at an individual with pre-existent musculoskeletal disorders, the medical recovery becomes more problematic. Some consequences, like negative affectivity and a reduced quality of life intervene to varying degrees.
Material and method. Our study included 150 outpatients who were diagnosed with stroke and one of five types of musculoskeletal disorders (low back pain, osteoporosis, hand disorders, hip osteoarthritis, knee osteoarthritis). We divided all the patients in five sub-groups. To assess the negative affectivity (anxiety) and quality of life we administered to the patients two scales: the State Trait Anxiety Inventory (STAI) form X1 (anxiety a s a state) and form X2 (anxiety as a trait) and The Quality of Life (QOL).
Results. In patients diagnosed with stroke and osteoporosis, the quality of life was 83.92% of the maximum value. Anxiety as a state rated at an average of 50.5 and anxiety as a trait rated at an average of 45. In the case of stroke and degenerative diseases at the lower limbs, we registered the quality of life of 77.68% in knee osteoarthritis and 75.89% in hip osteoarthritis; anxiety as a condition had an average value of 65 and, as a trait, a value of 63 in knee osteoarthritis, while in hip osteoarthritis the anxiety as a condition, and, in the same time, as a trait, rated both at 49.5. Low back pain in stroke patients had a quality of life of 77.86% of the maximum value; anxiety as a condition was 48 and the anxiety trait has the value of 47. For the patients with stroke and hand disease, the quality of life was assessed at 88.83%. Anxiety as a condition recorded an average value of 48 and the average value of 51 for anxiety as a trait recorded an average value of 51.
Conclusions. The lowest score of quality of life is recorded in the patient diagnosed with stroke and hip osteoarthritis (75.89% of the maximum value). This association converges with body dynamics, as the overlap of these two medical conditions may explain reduced functionality. The value of anxiety as a condition and also as a trait was higher in patients with stroke and osteoarthritis of the knee (65 and 63, respectively). The latter result is understandable, as intense pain and, therefore, discomfort related to osteoarthritis of the knee is well known.
Keywords: stroke, anxiety, quality of life, musculoskeletal conditions,
Collapse
Affiliation(s)
- Juliánna SZAKÁCS
- George Emil Palade University of Medicine, Pharmacy, Science, and Technology of Targu Mures, Faculty of Medicine, Department of Biophysics, Targu Mureș, Romania
| | - Lavinia-Corina DUICA
- Lucian Blaga University of Sibiu, Faculty of Medicine, Sibiu, Romania 3Hospital of Psychiatry „Doctor Gheorghe Preda” Sibiu, România
| | - Mihaela RACHERIU
- Lucian Blaga University of Sibiu, Faculty of Medicine, Sibiu, Romania, County Clinical Emergency Hospital, Sibiu, Romania
| |
Collapse
|
9
|
Zhang D, Chen B, Mu Q, Wang W, Liang K, Wang L, Wang Q. Topical delivery of gambogic acid assisted by the combination of low-frequency ultrasound and chemical enhancers for chemotherapy of cutaneous melanoma. Eur J Pharm Sci 2021; 166:105975. [PMID: 34391880 DOI: 10.1016/j.ejps.2021.105975] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/07/2021] [Revised: 07/30/2021] [Accepted: 08/10/2021] [Indexed: 10/20/2022]
Abstract
Anti-cutaneous melanoma activity of the skin-delivered gambogic acid (GA) has been reported in our previous study. However, it is difficult for GA to diffuse passively through intact skin without any enhancement means. In this study, a combination of chemical enhancers (EN: azone and propylene glycol) and physical ultrasound (US) was used to improve the percutaneous permeation of GA and enhance the anti-melanoma activity. The enhancement effect of the combination of EN and US (EN-US) on GA in vitro and in vivo was studied, and the enhancement mechanism and skin irritation were also evaluated. We showed that the parameters of US application at a constant frequency (30 kHz) with a duty cycle of 100% and intensity of 1.75 W/cm2 for 20 min were optimal. In vitro, EN-US showed a considerable enhancement of the permeation of GA, and the enhancement effect was stronger than that with the use of EN or US alone. In vivo antitumor study showed that the tumor growth was significantly inhibited after percutaneous administration of GA by EN-US, more than in the intravenous injection group. The penetration enhancement mechanism revealed that EN-US not only altered the structure of lipid bilayers and keratins to reduce the barrier effect of the stratum corneum but also produced diffusion channels in the skin under the cavitation effect of US, thereby promoting the skin penetration of GA. In addition, there was no observable skin irritation in mice after treatment with EN-US. Our study demonstrated that the combination of EN and US improved the skin permeation and retention of GA to enhance the anti-melanoma activity. This method also provides technical guidance for the future development of topical and transdermal therapeutic system of GA.
Collapse
Affiliation(s)
- Ding Zhang
- State Key Laboratory of Fine Chemicals, Department of Pharmaceutical Sciences, School of Chemical Engineering, Dalian University of Technology, No. 2 Linggong Road, Ganjingzi District, Dalian, Liaoning 116024, China
| | - Boqi Chen
- State Key Laboratory of Fine Chemicals, Department of Pharmaceutical Sciences, School of Chemical Engineering, Dalian University of Technology, No. 2 Linggong Road, Ganjingzi District, Dalian, Liaoning 116024, China
| | - Qingke Mu
- School of Bioengineering, Dalian University of Technology, Dalian, Liaoning 116024, China
| | - Wei Wang
- State Key Laboratory of Fine Chemicals, Department of Pharmaceutical Sciences, School of Chemical Engineering, Dalian University of Technology, No. 2 Linggong Road, Ganjingzi District, Dalian, Liaoning 116024, China
| | - Kaili Liang
- State Key Laboratory of Fine Chemicals, Department of Pharmaceutical Sciences, School of Chemical Engineering, Dalian University of Technology, No. 2 Linggong Road, Ganjingzi District, Dalian, Liaoning 116024, China
| | - Liyan Wang
- State Key Laboratory of Fine Chemicals, Department of Pharmaceutical Sciences, School of Chemical Engineering, Dalian University of Technology, No. 2 Linggong Road, Ganjingzi District, Dalian, Liaoning 116024, China
| | - Qing Wang
- State Key Laboratory of Fine Chemicals, Department of Pharmaceutical Sciences, School of Chemical Engineering, Dalian University of Technology, No. 2 Linggong Road, Ganjingzi District, Dalian, Liaoning 116024, China.
| |
Collapse
|
10
|
Martínez-Segoviano IDJ, Ganem-Rondero A. Enhancement of the transdermal delivery of zidovudine by pretreating the skin with two physical enhancers: microneedles and sonophoresis. ACTA ACUST UNITED AC 2021; 29:279-290. [PMID: 34216369 DOI: 10.1007/s40199-021-00402-y] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/17/2020] [Accepted: 05/25/2021] [Indexed: 11/28/2022]
Abstract
BACKGROUND Zidovudine (AZT) has been the most widely used drug for antiretroviral therapy. In order to improve the therapy with this drug, different alternatives have been proposed, such as the transdermal administration. The use of permeation enhancers is necessary to favor the passage of this drug through the skin, due to its physicochemical properties and to the natural permeation barrier imposed by the skin. OBJECTIVES To evaluate the effect of two permeation enhancers, sonophoresis and microneedles, on the permeability of AZT through the skin. METHODS Permeation studies with an AZT solution were performed using pigskin clamped in Franz-type cells. Sonophoresis was applied under different conditions (i.e., amplitude, duty cycle and application time), selected according to an experimental design, where the response variables were the increase in temperature of the skin surface and the increase in transepidermal water loss. ATR-FTIR was also used to demonstrate the effect of enhancers on membrane components. RESULTS The permeability of AZT through intact skin was very poor, with a very long lag time. Pretreatment of the skin with sonophoresis increased AZT transport significantly, reducing the lag time. The maximum flux (27.52 µgcm-2 h-1) and the highest total amount permeated (about 624 µg/cm2) were obtained when applying sonophoresis in continuous mode, with an amplitude of 20%, and an application time of 2 min. Sonophoresis appears to have an impact on stratum corneum proteins. The use of microneedles further increased the flux (30.41 µgcm-2 h-1) and the total amount permeated (about 916 µg/cm2), relative to sonophoresis. CONCLUSION The results are encouraging in terms of promoting AZT transport through the skin using sonophoresis or microneedles as permeation enhancers.
Collapse
Affiliation(s)
- Irene de Jesús Martínez-Segoviano
- División de Estudios de Posgrado (Tecnología Farmacéutica), Facultad de Estudios Superiores Cuautitlán, Universidad Nacional Autónoma de México, Av. 1o de Mayo s/n, 54740, Cuautitlán Izcalli, Estado de México, Mexico
| | - Adriana Ganem-Rondero
- División de Estudios de Posgrado (Tecnología Farmacéutica), Facultad de Estudios Superiores Cuautitlán, Universidad Nacional Autónoma de México, Av. 1o de Mayo s/n, 54740, Cuautitlán Izcalli, Estado de México, Mexico.
| |
Collapse
|
11
|
Uddin SMZ, Komatsu DE, Motyka T, Petterson S. Low-Intensity Continuous Ultrasound Therapies—A Systematic Review of Current State-of-the-Art and Future Perspectives. J Clin Med 2021; 10:2698. [PMID: 34207333 PMCID: PMC8235587 DOI: 10.3390/jcm10122698] [Citation(s) in RCA: 20] [Impact Index Per Article: 6.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/30/2021] [Revised: 06/10/2021] [Accepted: 06/14/2021] [Indexed: 01/02/2023] Open
Abstract
Therapeutic ultrasound has been studied for over seven decades for different medical applications. The versatility of ultrasound applications are highly dependent on the frequency, intensity, duration, duty cycle, power, wavelength, and form. In this review article, we will focus on low-intensity continuous ultrasound (LICUS). LICUS has been well-studied for numerous clinical disorders, including tissue regeneration, pain management, neuromodulation, thrombosis, and cancer treatment. PubMed and Google Scholar databases were used to conduct a comprehensive review of all research studying the application of LICUS in pre-clinical and clinical studies. The review includes articles that specify intensity and duty cycle (continuous). Any studies that did not identify these parameters or used high-intensity and pulsed ultrasound were not included in the review. The literature review shows the vast implication of LICUS in many medical fields at the pre-clinical and clinical levels. Its applications depend on variables such as frequency, intensity, duration, and type of medical disorder. Overall, these studies show that LICUS has significant promise, but conflicting data remain regarding the parameters used, and further studies are required to fully realize the potential benefits of LICUS.
Collapse
Affiliation(s)
- Sardar M. Z. Uddin
- Department of Orthopaedics and Rehabilitation, Stony Brook University, Stony Brook, NY 11794, USA;
| | - David E. Komatsu
- Department of Orthopaedics and Rehabilitation, Stony Brook University, Stony Brook, NY 11794, USA;
| | - Thomas Motyka
- Department of Osteopathic Manipulative Medicine, Campbell University, Buies Creek, NC 27506, USA;
| | | |
Collapse
|
12
|
Transdermal drug delivery systems for fighting common viral infectious diseases. Drug Deliv Transl Res 2021; 11:1498-1508. [PMID: 34024014 PMCID: PMC8140753 DOI: 10.1007/s13346-021-01004-6] [Citation(s) in RCA: 19] [Impact Index Per Article: 6.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Accepted: 05/14/2021] [Indexed: 02/08/2023]
Abstract
Transdermal drug delivery systems (TDDS) have many advantages and represent an excellent alternative to oral delivery and hypodermic injections. TDDS are more convenient and less invasive tools for disease and viral infection treatment, prevention, detection, and surveillance. The emerging development of microneedles for TDDS has facilitated improved skin barrier penetration for the delivery of macromolecules or hydrophilic drugs. Microneedle TDDS patches can be fabricated to deliver virus vaccines and potentially provide a viable alternative vaccine modality that offers improved immunogenicity, thermostability, simplicity, safety, and compliance as well as sharp-waste reduction, increased cost-effectiveness, and the capacity for self-administration, which could improve vaccine distribution. These advantages make TDDS-based vaccine delivery an especially well-suited option for treatment of widespread viral infectious diseases including pandemics. Because microneedle-based bioassays employ transdermal extraction of interstitial fluid or blood, they can be used as a minimally invasive approach for surveying disease markers and providing point-of-care (POC) diagnostics. For cutaneous viral infections, TDDS can provide localized treatment with high specificity and less systemic toxicity. In summary, TDDS, especially those that employ microneedles, possess special attributes that can be leveraged to reduce morbidity and mortality from viral infectious diseases. In this regard, they may have considerable positive impact as a modality for improving global health. In this article, we introduce the possible role and summarize the current literature regarding TDDS applications for fighting common cutaneous or systemic viral infectious diseases, including herpes simplex, varicella or herpes zoster, warts, influenza, measles, and COVID-19.
Collapse
|
13
|
Taheri P, Naderi M, Khosravi S. Extracorporeal Shock Wave Therapy Versus Phonophoresis Therapy for Neck Myofascial Pain Syndrome: A Randomized Clinical Trial. Anesth Pain Med 2021; 11:e112592. [PMID: 34336620 PMCID: PMC8314093 DOI: 10.5812/aapm.112592] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/29/2020] [Revised: 03/06/2021] [Accepted: 03/12/2021] [Indexed: 11/16/2022] Open
Abstract
OBJECTIVES This study aimed to assess the effects of using Extracorporeal Shock Wave Therapy (ECSWT) and phonophoresis therapy on pain and neck disability in patients with neck myofascial pain syndrome (MPS). METHODS Forty eligible patients were randomly divided into two groups of ECSWT (received three sessions of ECSWT, once a week for three weeks) and phonophoresis (received ultrasound using hydrocortisone gel 1% over the trigger point on trapezius muscle, three times a week for three weeks). Patients in both groups received the same stretching exercise program and drug regimen during the intervention. RESULTS Pain and NDI scores in both groups were significantly improved at the end of the treatment and four weeks later. At the end of the treatment, the pain score was similar between the groups. Four weeks after the treatment, the pain score in the ECSWT group was significantly lower than in the phonophoresis group (P-value = 0.030). The NDI score was not significantly different between the groups at the end of the treatment. However, four weeks after the treatment, the NDI score was significantly lower in the ECSWT group than in the phonophoresis group (P-value=0.032). The trend of changes in the pain and NDI scores was not significantly different between the groups. CONCLUSIONS Both phonophoresis and ECSWT groups effectively decreased pain and neck disability in patients with MPS, with the superiority of ECSWT with a more lasting effect for a month after the end of the treatment.
Collapse
Affiliation(s)
- Parisa Taheri
- Department of Physical Medicine and Rehabilitation, School of Medicine, Isfahan University of Medical Sciences, Isfahan, Iran
| | - Marzie Naderi
- Department of Physical Medicine and Rehabilitation, School of Medicine, Isfahan University of Medical Sciences, Isfahan, Iran
| | - Saeid Khosravi
- Department of Physical Medicine and Rehabilitation, School of Medicine, Isfahan University of Medical Sciences, Isfahan, Iran
| |
Collapse
|
14
|
Enhancement strategies for transdermal drug delivery systems: current trends and applications. Drug Deliv Transl Res 2021; 12:758-791. [PMID: 33474709 PMCID: PMC7817074 DOI: 10.1007/s13346-021-00909-6] [Citation(s) in RCA: 124] [Impact Index Per Article: 41.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Accepted: 01/13/2021] [Indexed: 12/11/2022]
Abstract
Transdermal drug delivery systems have become an intriguing research topic in pharmaceutical technology area and one of the most frequently developed pharmaceutical products in global market. The use of these systems can overcome associated drawbacks of other delivery routes, such as oral and parenteral. The authors will review current trends, and future applications of transdermal technologies, with specific focus on providing a comprehensive understanding of transdermal drug delivery systems and enhancement strategies. This article will initially discuss each transdermal enhancement method used in the development of first-generation transdermal products. These methods include drug/vehicle interactions, vesicles and particles, stratum corneum modification, energy-driven methods and stratum corneum bypassing techniques. Through suitable design and implementation of active stratum corneum bypassing methods, notably microneedle technology, transdermal delivery systems have been shown to deliver both low and high molecular weight drugs. Microneedle technology platforms have proven themselves to be more versatile than other transdermal systems with opportunities for intradermal delivery of drugs/biotherapeutics and therapeutic drug monitoring. These have shown that microneedles have been a prospective strategy for improving transdermal delivery systems.
Collapse
|
15
|
Dorji K, Graham N, Macedo L, Gravesande J, Goldsmith CH, Gelley G, Rice M, Solomon P. The effect of ultrasound or phonophoresis as an adjuvant treatment for non-specific neck pain: systematic review of randomised controlled trials. Disabil Rehabil 2020; 44:2968-2974. [PMID: 33253599 DOI: 10.1080/09638288.2020.1851785] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/22/2022]
Abstract
OBJECTIVE To determine the effectiveness of ultrasound/phonophoresis as an adjuvant to exercise or manual therapy for the improvement of patient-centred outcomes in adults with non-specific neck pain (NSNP). METHODS Seven electronic databases were systematically searched up to September 2020. The Grading of Recommendations, Assessment, Development and Evaluation (GRADE) approach was used to judge the Quality of Evidence (QoE). RESULTS Six studies involving 249 participants were included. The QoE was very low GRADE. Phonophoresis with capsaicin plus exercise improved pain at immediate post-treatment (MD: -3.30 [-4.05, -2.55]) but not with diclofenac sodium plus exercise as compared to exercise. Continuous ultrasound (CUS) plus exercise improved pain and pressure pain threshold (PPT) at immediate post-treatment (pain: MD: -3.42 [-4.08, -2.7]); (PPT: MD: 0.91 [0.68, 1.14]) and at intermediate-term as compared to exercise. CUS or high power pain threshold (HPPT) ultrasound plus manual therapy and exercise showed no benefit for pain reduction (MD: -0.75 [-2.08, 0.58]) did not improve function/disability (MD: -1.05 [-4.27, 2.17]) at immediate or short-term as compared to manual therapy and exercise. CONCLUSIONS Due to high risk of bias, inconsistency, and indirectness the QoE is very low in support of benefit of ultrasound/phonophoresis as an adjuvant treatment for NSNP.Implication for rehabilitationDue to high risk of bias, inconsistency, and indirectness the quality of evidence (QoE) is very low in support of benefit of adding ultrasound or phonophoresis to exercise or manual therapy for pain reduction or improvement in function/disability for those with sub-acute and chronic myofascial associated neck pain. However, our confidence in the findings is very low and conclusions are likely to change as more evidences emerges.Clinicians using ultrasound therapy as an adjuvant intervention for management of chronic myofascial associated neck pain should carefully consider the available evidence on ultrasound, including the benefits and costs involved.
Collapse
Affiliation(s)
- Kinley Dorji
- School of Rehabilitation Science, McMaster University, Hamilton, Canada
| | - Nadine Graham
- School of Rehabilitation Science, McMaster University, Hamilton, Canada
| | - Luciana Macedo
- School of Rehabilitation Science, McMaster University, Hamilton, Canada
| | | | - Charles H Goldsmith
- Department of Health Research Methods, Evidence and Impact, McMaster University, Hamilton, Canada.,Department of Health Research Methods, Faculty of Health Sciences, Simon Fraser University, Burnaby, Canada.,Department of Occupational Science and Occupational Therapy, Faculty of Medicine, The University of British Columbia, Vancouver, Canada
| | - Geoffrey Gelley
- College of Rehabilitation Sciences, Rady Faculty of Health Sciences, University of Manitoba, Winnipeg, Canada
| | - Maureen Rice
- Department of Health Research Methods, Evidence and Impact, McMaster University, Hamilton, Canada
| | - Patricia Solomon
- School of Rehabilitation Science, McMaster University, Hamilton, Canada
| |
Collapse
|
16
|
Chowdhury SM, Abou-Elkacem L, Lee T, Dahl J, Lutz AM. Ultrasound and microbubble mediated therapeutic delivery: Underlying mechanisms and future outlook. J Control Release 2020; 326:75-90. [PMID: 32554041 DOI: 10.1016/j.jconrel.2020.06.008] [Citation(s) in RCA: 108] [Impact Index Per Article: 27.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/21/2020] [Revised: 06/06/2020] [Accepted: 06/09/2020] [Indexed: 12/20/2022]
Abstract
Beyond the emerging field of oncological ultrasound molecular imaging, the recent significant advancements in ultrasound and contrast agent technology have paved the way for therapeutic ultrasound mediated microbubble oscillation and has shown that this approach is capable of increasing the permeability of microvessel walls while also initiating enhanced extravasation and drug delivery into target tissues. In addition, a large number of preclinical studies have demonstrated that ultrasound alone or combined with microbubbles can efficiently increase cell membrane permeability resulting in enhanced tissue distribution and intracellular drug delivery of molecules, nanoparticles, and other therapeutic agents. The mechanism behind the enhanced permeability is the temporary creation of pores in cell membranes through a phenomenon called sonoporation by high-intensity ultrasound and microbubbles or cavitation agents. At low ultrasound intensities (0.3-3 W/cm2), sonoporation may be caused by microbubbles oscillating in a stable motion, also known as stable cavitation. In contrast, at higher ultrasound intensities (greater than 3 W/cm2), sonoporation usually occurs through inertial cavitation that accompanies explosive growth and collapse of the microbubbles. Sonoporation has been shown to be a highly effective method to improve drug uptake through microbubble potentiated enhancement of microvascular permeability. In this review, the therapeutic strategy of using ultrasound for improved drug delivery are summarized with the special focus on cancer therapy. Additionally, we discuss the progress, challenges, and future of ultrasound-mediated drug delivery towards clinical translation.
Collapse
Affiliation(s)
- Sayan Mullick Chowdhury
- Department of Radiology, Molecular Imaging Program at Stanford, Stanford University School of Medicine, Stanford, CA, USA
| | - Lotfi Abou-Elkacem
- Department of Radiology, Molecular Imaging Program at Stanford, Stanford University School of Medicine, Stanford, CA, USA
| | - Taehwa Lee
- Department of Radiology, Molecular Imaging Program at Stanford, Stanford University School of Medicine, Stanford, CA, USA
| | - Jeremy Dahl
- Department of Radiology, Molecular Imaging Program at Stanford, Stanford University School of Medicine, Stanford, CA, USA
| | - Amelie M Lutz
- Department of Radiology, Molecular Imaging Program at Stanford, Stanford University School of Medicine, Stanford, CA, USA.
| |
Collapse
|
17
|
Daftardar S, Bahl D, Boddu SHS, Altorok N, Kahaleh B. Ultrasound-mediated topical delivery of econazole nitrate with potential for treating Raynaud's phenomenon. Int J Pharm 2020; 580:119229. [PMID: 32184178 DOI: 10.1016/j.ijpharm.2020.119229] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/08/2020] [Revised: 03/10/2020] [Accepted: 03/13/2020] [Indexed: 01/09/2023]
Abstract
The study aims to assess the ultrasound-assisted econazole nitrate (EN) permeation from topically applied formulations with potential for treating Raynaud's phenomenon. Optimization of ultrasound parameters such as the distance of the horn, application time and amplitude were performed. In vitro percutaneous absorption studies were performed using econazole formulations (F2_HPMC dispersion, F4_Lipoderm® Activemax™ Cream) across the ultrasound-treated porcine skin and were compared with the control group (skin samples without ultrasound). Histology and ATR-FTIR studies were performed on treated skin samples. A constant frequency (20 kHz) ultrasound application with 40% amplitude, 0.5 cm distance between ultrasound horn and the skin surface for 2 min was optimized. The permeation of EN was found to be higher from ultrasound-treated skin samples than the control group. Drug permeation from F2_HPMC dispersion was found to be higher as compared to the other formulations and the marketed EN cream. Histological evaluation confirmed that F2_HPMC dispersion showed no signs of toxicity. ATR-FTIR studies revealed a slight increase in the CH2 stretching vibrations (~2920 cm-1 and 2850 cm-1) in ultrasound-treated skin samples as compared with the control. In conclusion, the ultrasound-assisted transdermal delivery of F2_HPMC dispersion could be further studied as a new therapy for Raynaud's phenomenon.
Collapse
Affiliation(s)
- Saloni Daftardar
- College of Pharmacy and Pharmaceutical Sciences, The University of Toledo Health Science Campus, The University of Toledo, Toledo, OH 43614, USA
| | - Dherya Bahl
- College of Pharmacy and Pharmaceutical Sciences, The University of Toledo Health Science Campus, The University of Toledo, Toledo, OH 43614, USA
| | - Sai H S Boddu
- College of Pharmacy and Pharmaceutical Sciences, The University of Toledo Health Science Campus, The University of Toledo, Toledo, OH 43614, USA; Department of Pharmaceutical Sciences, College of Pharmacy and Health Sciences, Ajman University, Ajman, United Arab Emirates.
| | - Nezam Altorok
- Department of Medicine, Division of Rheumatology, University of Toledo, Toledo, USA
| | - Bashar Kahaleh
- Department of Medicine, Division of Rheumatology, University of Toledo, Toledo, USA
| |
Collapse
|
18
|
Wu Y, Zhu S, Lv Z, Kan S, Wu Q, Song W, Ning G, Feng S. Effects of therapeutic ultrasound for knee osteoarthritis: a systematic review and meta-analysis. Clin Rehabil 2019; 33:1863-1875. [PMID: 31382781 DOI: 10.1177/0269215519866494] [Citation(s) in RCA: 33] [Impact Index Per Article: 6.6] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/23/2022]
Abstract
Objective: To assess the effectiveness and safety of therapeutic ultrasound with sham ultrasound on pain relief and functional improvement in knee osteoarthritis patients. As phonophoresis is a unique therapeutic ultrasound, we also compared the effects of phonophoresis with conventional non-drug ultrasound. Data sources: PubMed, EMBASE, and the Cochrane Library were systematically searched for randomized controlled trials from inception up to June 2019. Review methods: Randomized controlled trials comparing therapeutic ultrasound with sham ultrasound in knee osteoarthritis patients were included. Phonophoresis in the experimental and control groups were compared through conventional ultrasound, and corresponding trials were also included. Two reviewers independently identified eligible studies and extracted data. Risk of bias assessments and therapeutic ultrasound safety assessments were also performed. Results: Fifteen studies including three phonophoresis-related studies with 1074 patients were included. Meta-analyses demonstrated that therapeutic ultrasound significantly relieved pain ( P < 0.00001) and reduced the Western Ontario and McMaster Universities (WOMAC) physical function score ( P = 0.03). In addition, therapeutic ultrasound increased the active range of motion ( P < 0.00001) and reduced the Lequesne index ( P < 0.00001). Subgroup analysis of phonophoresis ultrasound illustrated significant differences on the visual analogue scale ( P = 0.009), but no significant differences on WOMAC pain subscales ( P = 0.10), and total WOMAC scores were observed ( P = 0.30). There was no evidence to suggest that ultrasound was unsafe treatment. Conclusions: Therapeutic ultrasound is a safe treatment to relieve pain and improve physical function in patients with knee osteoarthritis. However, phonophoresis does not produce additional benefits to functional improvement, but may relieve pain compared to conventional non-drug ultrasound.
Collapse
Affiliation(s)
- Yu Wu
- Department of Orthopaedics, Tianjin Medical University General Hospital, Tianjin, P.R. China
- Tianjin Neurological Institute, Key Laboratory of Post-Neuroinjury Neuro-repair and Regeneration in Central Nervous System, Ministry of Education and Tianjin City, Tianjin, P.R. China
| | - Shibo Zhu
- Department of Orthopaedics, Tianjin Medical University General Hospital, Tianjin, P.R. China
- Tianjin Neurological Institute, Key Laboratory of Post-Neuroinjury Neuro-repair and Regeneration in Central Nervous System, Ministry of Education and Tianjin City, Tianjin, P.R. China
| | - Zenghui Lv
- Department of Orthopaedics, Tianjin Medical University General Hospital, Tianjin, P.R. China
- Tianjin Neurological Institute, Key Laboratory of Post-Neuroinjury Neuro-repair and Regeneration in Central Nervous System, Ministry of Education and Tianjin City, Tianjin, P.R. China
| | - Shunli Kan
- Department of Spine Surgery, Tianjin Union Medical Center, Tianjin, P.R. China
| | - Qiuli Wu
- Department of Orthopaedics, Tianjin Medical University General Hospital, Tianjin, P.R. China
- Tianjin Neurological Institute, Key Laboratory of Post-Neuroinjury Neuro-repair and Regeneration in Central Nervous System, Ministry of Education and Tianjin City, Tianjin, P.R. China
| | - Wenye Song
- Department of Orthopaedics, Tianjin Medical University General Hospital, Tianjin, P.R. China
- Tianjin Neurological Institute, Key Laboratory of Post-Neuroinjury Neuro-repair and Regeneration in Central Nervous System, Ministry of Education and Tianjin City, Tianjin, P.R. China
| | - Guangzhi Ning
- Department of Orthopaedics, Tianjin Medical University General Hospital, Tianjin, P.R. China
- Tianjin Neurological Institute, Key Laboratory of Post-Neuroinjury Neuro-repair and Regeneration in Central Nervous System, Ministry of Education and Tianjin City, Tianjin, P.R. China
| | - Shiqing Feng
- Department of Orthopaedics, Tianjin Medical University General Hospital, Tianjin, P.R. China
- Tianjin Neurological Institute, Key Laboratory of Post-Neuroinjury Neuro-repair and Regeneration in Central Nervous System, Ministry of Education and Tianjin City, Tianjin, P.R. China
| |
Collapse
|
19
|
Manikkath J, Shenoy GG, Pandey S, Mutalik S. Response Surface Methodology for Optimization of Ultrasound-Assisted Transdermal Delivery and Skin Retention of Asenapine Maleate. J Pharm Innov 2019. [DOI: 10.1007/s12247-019-09386-4] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/17/2022]
|
20
|
Immediate Effects of Simultaneous Application of Transcutaneous Electrical Nerve Stimulation and Ultrasound Phonophoresis on Active Myofascial Trigger Points: A Randomized Controlled Trial. Am J Phys Med Rehabil 2019; 97:332-338. [PMID: 29206666 DOI: 10.1097/phm.0000000000000876] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/26/2022]
Abstract
OBJECTIVE The aim of the study was to investigate the efficacy of phonophoresis with combined therapy on active myofascial trigger points. PARTICIPANTS One hundred participants with acute mechanical neck pain and at least one active myofascial trigger point in the upper trapezius were randomly assigned into four equal groups. INTERVENTION Groups consisted of diclofenac phonophoresis with combined therapy, diclofenac phonophoresis, ultrasound (US) with coupling gel, and sham US and applied for 10 mins over myofascial trigger points. MEASUREMENTS Measurements included pressure pain threshold and active cervical lateral flexion. RESULTS There were statistically significant improvements in postintervention pressure pain threshold and range of motion values in treatment groups (P < 0.0001). As for the sham US, no significant difference was found between the preintervention and postintervention values (P > 0.05). Bonferroni correction test revealed that there was a significant difference between all the four groups in pressure pain threshold values (P < 0.0001); however, it was nonsignificant (P > 0.05) for range of motion. CONCLUSIONS Diclofenac phonophoresis with combined therapy, phonophoresis, and US were all effective in increasing pressure pain threshold values and range of motion. In addition, phonophoresis with combined therapy was shown to be superior over phonophoresis, and phonophoresis was superior over US in terms of reducing pain sensitivity. However, none of the treatment groups were found to be superior over the other in increasing range of motion.
Collapse
|
21
|
Cardoso LCP, Pinto NB, Nobre MEP, Silva MR, Pires GM, Lopes MJP, Viana GSB, Rodrigues LMR. Anti-inflammatory and antinociceptive effects of phonophoresis in animal models: a randomized experimental study. ACTA ACUST UNITED AC 2019; 52:e7773. [PMID: 30698227 PMCID: PMC6345359 DOI: 10.1590/1414-431x20187773] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/26/2018] [Accepted: 10/30/2018] [Indexed: 11/21/2022]
Abstract
The aim of this study was to evaluate the therapeutic effects of ultrasound (US)-mediated phonophoresis alone or in association with diclofenac diethylammonium (DCF) administered topically in animal models of inflammation. A pre-clinical, prospective, and randomized experimental study of quantitative and qualitative nature was carried out. Phonophoresis was performed using a therapeutic ultrasound apparatus in two distinct models of acute inflammation. Edema was induced by an intraplantar injection of carrageenan and measured by plethysmography. The Hargreaves test was used to evaluate the antinociceptive activity and investigate the action of phonophoresis on tumor necrosis factor (TNF)-α production. A histological analysis with hematoxylin-eosin was used to evaluate tissue repair, and the expression of COX-2 was determined by immunohistochemical analysis. At the peak of inflammatory activity (3 h), treatment with US, US+DCF, and DCF significantly reduced edema formation compared to the control group. Treatment with US+DCF was more effective than treatment with US alone at both analyzed times. In the analysis of the antinociceptive activity, the treatments significantly increased the latency time in response to the thermal stimulus. Histopathological analysis revealed a reduction of the inflammatory infiltrates and immunohistochemistry demonstrated that the association was effective in reducing COX-2 expression compared to the control group. The association of DCF with US produced anti-inflammatory and antinociceptive effects in rat models of inflammation, which may be associated with inhibition of COX-2 and TNF-α production.
Collapse
Affiliation(s)
- L C P Cardoso
- Programa de Pós-Graduação Stricto Sensu em Ciências da Saúde, Faculdade de Medicina do ABC, Santo André, SP, Brasil
| | - N B Pinto
- Unidade Acadêmica Ciências da Vida, Universidade Federal de Campina Grande, Cajazeiras, PB, Brasil
| | - M E P Nobre
- Faculdade de Medicina, Universidade Federal de Cariri, Barbalha, CE, Brasil
| | - M R Silva
- Departamento de Farmacologia, Universidade Federal do Ceará, Fortaleza, CE, Brasil
| | - G M Pires
- Departamento de Ciências da Computação, Inteligência e Processamento de Imagens, Universidade Federal Rural de Pernambuco, Serra Talhada, PE, Brasil
| | - M J P Lopes
- Laboratório de Fisiologia, Faculdade de Medicina Estácio de Juazeiro do Norte, Juazeiro do Norte, CE, Brasil
| | - G S B Viana
- Departamento de Farmacologia, Universidade Federal do Ceará, Fortaleza, CE, Brasil
| | - L M R Rodrigues
- Programa de Pós-Graduação Stricto Sensu em Ciências da Saúde, Faculdade de Medicina do ABC, Santo André, SP, Brasil
| |
Collapse
|
22
|
Altan L, Kasapoğlu Aksoy M, Kösegil Öztürk E. Efficacy of diclofenac & thiocolchioside gel phonophoresis comparison with ultrasound therapy on acute low back pain; a prospective, double-blind, randomized clinical study. ULTRASONICS 2019; 91:201-205. [PMID: 30139568 DOI: 10.1016/j.ultras.2018.08.008] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 11/28/2017] [Revised: 06/29/2018] [Accepted: 08/12/2018] [Indexed: 06/08/2023]
Abstract
PURPOSE To investigate the effect of Phonophoresis (PP) with the combination of nonsteroidal anti-inflammatory drugs (NSAID's) and myorelaxant versus routine Ultrasound (US) treatment with non-therapeutic gel on the patients with acute low back pain (ABP). METHODS Sixty patients with ABP were randomly assigned into 2 groups. In Group 1 (n = 30) US was applied using diclofenac + Thiocolchicoside gel for 10 min and for a total of 10 sessions. In Group 2 (n = 30) the same US protocol was applied with the same setting and timing with Group 1 using US gel that does not contain any pharmaceutical ingredient. Evaluation parameters were Visual numeric scale (VNS), Oswestry Disability Index (ODI), and Shober test. RESULTS Comparison of the results obtained from the two groups before treatment and at second (W2) and sixth weeks (W6) posttreatment showed significant improvement in all parameters in both groups (p < 0.05). Comparison of the groups showed significantly superior improvement in Group 1 for ODI while there was no difference in other parameters at W2. At W6, there was significantly superior improvement in all parameters (p < 0.05) except for Shober test in Group1. CONCLUSION Our results showed that PP treatment is superior than conventional US therapy at short term in ABP patients.
Collapse
Affiliation(s)
- L Altan
- Uludağ University Medicine Faculty, Department of Physical Medicine and Rehabilitation, Turkey; University of Health Sciences Bursa Yüksek Ihtisas Training and Research Hospital, Department of Physical Medicine and Rehabilitation, Turkey
| | - M Kasapoğlu Aksoy
- University of Health Sciences Bursa Yüksek Ihtisas Training and Research Hospital, Department of Physical Medicine and Rehabilitation, Turkey.
| | - E Kösegil Öztürk
- University of Health Sciences Bursa Yüksek Ihtisas Training and Research Hospital, Department of Physical Medicine and Rehabilitation, Turkey
| |
Collapse
|
23
|
Abstract
Over the past few decades, applications of ultrasound (US) in drug delivery have been documented widely for local and site-specific release of bioactives in a controlled manner, after acceptable use in mild physical therapy for tendinitis and bursitis, and for high-energy applications in fibroid ablation, cataract removal, bone fracture healing, etc. US is a non-invasive, efficient, targetable and controllable technique. Drug delivery can be enhanced by applying directed US in terms of targeting and intracellular uptake. US cannot only provide local hyperthermia but can also enhance local extravasations and permeability of the cell membrane for delivery of cell-impermeable and poorly permeable drugs. It is also found to increase the anticancer efficacy of drug against solid tumors by facilitating uniform drug delivery throughout the tumor mass. This review summarizes the mechanism of US; various drug delivery systems like microbubbles, liposomes, and micelles; and biological manifestations employed for improving treatment of cancer, i.e., hyperthermia and enhanced extravasation. Safety issues are also discussed for better therapeutic outcomes of US-assisted drug delivery to tumors. This review can be a beneficial asset to the scientists looking at non-invasive techniques (externally guided) for improving the anticancer potential of drug delivery systems.
Collapse
|
24
|
Maresca D, Lakshmanan A, Abedi M, Bar-Zion A, Farhadi A, Lu GJ, Szablowski JO, Wu D, Yoo S, Shapiro MG. Biomolecular Ultrasound and Sonogenetics. Annu Rev Chem Biomol Eng 2018; 9:229-252. [PMID: 29579400 PMCID: PMC6086606 DOI: 10.1146/annurev-chembioeng-060817-084034] [Citation(s) in RCA: 82] [Impact Index Per Article: 13.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/01/2023]
Abstract
Visualizing and modulating molecular and cellular processes occurring deep within living organisms is fundamental to our study of basic biology and disease. Currently, the most sophisticated tools available to dynamically monitor and control cellular events rely on light-responsive proteins, which are difficult to use outside of optically transparent model systems, cultured cells, or surgically accessed regions owing to strong scattering of light by biological tissue. In contrast, ultrasound is a widely used medical imaging and therapeutic modality that enables the observation and perturbation of internal anatomy and physiology but has historically had limited ability to monitor and control specific cellular processes. Recent advances are beginning to address this limitation through the development of biomolecular tools that allow ultrasound to connect directly to cellular functions such as gene expression. Driven by the discovery and engineering of new contrast agents, reporter genes, and bioswitches, the nascent field of biomolecular ultrasound carries a wave of exciting opportunities.
Collapse
Affiliation(s)
- David Maresca
- Division of Chemistry and Chemical Engineering, California Institute of Technology, Pasadena, California 91125, USA;
| | - Anupama Lakshmanan
- Division of Biology and Biological Engineering, California Institute of Technology, Pasadena, California 91125, USA
| | - Mohamad Abedi
- Division of Biology and Biological Engineering, California Institute of Technology, Pasadena, California 91125, USA
| | - Avinoam Bar-Zion
- Division of Chemistry and Chemical Engineering, California Institute of Technology, Pasadena, California 91125, USA;
| | - Arash Farhadi
- Division of Biology and Biological Engineering, California Institute of Technology, Pasadena, California 91125, USA
| | - George J Lu
- Division of Chemistry and Chemical Engineering, California Institute of Technology, Pasadena, California 91125, USA;
| | - Jerzy O Szablowski
- Division of Chemistry and Chemical Engineering, California Institute of Technology, Pasadena, California 91125, USA;
| | - Di Wu
- Division of Engineering and Applied Sciences, California Institute of Technology, Pasadena, California 91125, USA
| | - Sangjin Yoo
- Division of Chemistry and Chemical Engineering, California Institute of Technology, Pasadena, California 91125, USA;
| | - Mikhail G Shapiro
- Division of Chemistry and Chemical Engineering, California Institute of Technology, Pasadena, California 91125, USA;
| |
Collapse
|
25
|
Pompilio da Silva M, Tamaoki MJS, Blumetti FC, Belloti JC, Smidt N, Buchbinder R. Electrotherapy modalities for lateral elbow pain. Hippokratia 2018. [DOI: 10.1002/14651858.cd013041] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/11/2022]
Affiliation(s)
- Milla Pompilio da Silva
- Universidade Federal de São Paulo; Department of Orthopaedics and Traumatology; R. Borges Lagoa, 783 - 5º Andar ? Vila Clementino São Paulo Brazil 04032-038
| | - Marcel JS Tamaoki
- Universidade Federal de São Paulo; Department of Orthopaedics and Traumatology; R. Borges Lagoa, 783 - 5º Andar ? Vila Clementino São Paulo Brazil 04032-038
| | - Francesco C Blumetti
- Universidade Federal de São Paulo; Department of Orthopaedics and Traumatology; R. Borges Lagoa, 783 - 5º Andar ? Vila Clementino São Paulo Brazil 04032-038
| | - João Carlos Belloti
- Universidade Federal de São Paulo; Department of Orthopaedics and Traumatology; R. Borges Lagoa, 783 - 5º Andar ? Vila Clementino São Paulo Brazil 04032-038
- Escola Paulista de Medicina; São Paulo Brazil
| | - Nynke Smidt
- University Medical Center Groningen, University of Groningen; Department of Epidemiology; Hanzeplein (Entrance 24) Groningen Groningen Netherlands PO Box 30.001, 9700 RB
| | - Rachelle Buchbinder
- Department of Epidemiology and Preventive Medicine, School of Public Health and Preventive Medicine, Monash University; Monash Department of Clinical Epidemiology, Cabrini Institute; 4 Drysdale Street Malvern Victoria Australia 3144
| |
Collapse
|
26
|
Canavese G, Ancona A, Racca L, Canta M, Dumontel B, Barbaresco F, Limongi T, Cauda V. Nanoparticle-assisted ultrasound: A special focus on sonodynamic therapy against cancer. CHEMICAL ENGINEERING JOURNAL (LAUSANNE, SWITZERLAND : 1996) 2018; 340:155-172. [PMID: 30881202 PMCID: PMC6420022 DOI: 10.1016/j.cej.2018.01.060] [Citation(s) in RCA: 226] [Impact Index Per Article: 37.7] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/06/2023]
Abstract
At present, ultrasound radiation is broadly employed in medicine for both diagnostic and therapeutic purposes at various frequencies and intensities. In this review article, we focus on therapeutically-active nanoparticles (NPs) when stimulated by ultrasound. We first introduce the different ultrasound-based therapies with special attention to the techniques involved in the oncological field, then we summarize the different NPs used, ranging from soft materials, like liposomes or micro/nano-bubbles, to metal and metal oxide NPs. We therefore focus on the sonodynamic therapy and on the possible working mechanisms under debate of NPs-assisted sonodynamic treatments. We support the idea that various, complex and synergistics physical-chemical processes take place during acoustic cavitation and NP activation. Different mechanisms are therefore responsible for the final cancer cell death and strongly depends not only on the type and structure of NPs or nanocarriers, but also on the way they interact with the ultrasonic pressure waves. We conclude with a brief overview of the clinical applications of the various ultrasound therapies and the related use of NPs-assisted ultrasound in clinics, showing that this very innovative and promising approach is however still at its infancy in the clinical cancer treatment.
Collapse
Affiliation(s)
- Giancarlo Canavese
- Department of Applied Science and Technology, Politecnico di Torino, Corso Duca degli Abruzzi 24, 10129 Turin, Italy
- Center for Sustainable Future Technologies CSFT@Polito, Istituto Italiano di Tecnologia, Corso Trento 21, 10129, Turin, Italy
| | - Andrea Ancona
- Department of Applied Science and Technology, Politecnico di Torino, Corso Duca degli Abruzzi 24, 10129 Turin, Italy
| | - Luisa Racca
- Department of Applied Science and Technology, Politecnico di Torino, Corso Duca degli Abruzzi 24, 10129 Turin, Italy
| | - Marta Canta
- Department of Applied Science and Technology, Politecnico di Torino, Corso Duca degli Abruzzi 24, 10129 Turin, Italy
| | - Bianca Dumontel
- Department of Applied Science and Technology, Politecnico di Torino, Corso Duca degli Abruzzi 24, 10129 Turin, Italy
| | - Federica Barbaresco
- Department of Applied Science and Technology, Politecnico di Torino, Corso Duca degli Abruzzi 24, 10129 Turin, Italy
| | - Tania Limongi
- Department of Applied Science and Technology, Politecnico di Torino, Corso Duca degli Abruzzi 24, 10129 Turin, Italy
| | - Valentina Cauda
- Department of Applied Science and Technology, Politecnico di Torino, Corso Duca degli Abruzzi 24, 10129 Turin, Italy
- Center for Sustainable Future Technologies CSFT@Polito, Istituto Italiano di Tecnologia, Corso Trento 21, 10129, Turin, Italy
- Corresponding author at: Department of Applied Science and Technology, Politecnico di Torino, Corso Duca degli Abruzzi 24, 10129 Turin, Italy. (V. Cauda)
| |
Collapse
|
27
|
Vahdatpour B, Mokhtarian A, Raeissadat SA, Dehghan F, Nasr N, Mazaheri M. Enhancement of the Effectiveness of Extracorporeal Shock Wave Therapy with Topical Corticosteroid in Treatment of Chronic Plantar Fasciitis: A Randomized Control Clinical Trial. Adv Biomed Res 2018; 7:62. [PMID: 29862211 PMCID: PMC5952528 DOI: 10.4103/abr.abr_40_17] [Citation(s) in RCA: 10] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/31/2022] Open
Abstract
BACKGROUND Chronic recalcitrant plantar fasciitis is a disabling condition. We presumed if shock wave could increase the permeability of skin and facilitate penetration of topical corticosteroid through the skin; the combinational therapeutic effect would be stronger than using shock wave alone. The study purpose was to utilize the synergistic effect of shock wave and topical corticosteroid in treatment of plantar fasciitis. MATERIALS AND METHODS Patients in both groups (n = 40) received four sessions of shock wave with the same protocol at weekly intervals. At 30 min before each session, we used an occlusive dressing of topical clobetasol for the intervention group and Vaseline oil for the control group. Pain severity was assessed with visual analog scale (VAS) and modified Roles and Maudsley score (RMS) at baseline and 1 month and 3 months after intervention. Plantar fascia (PF) thickness was measured with ultrasonography at baseline and 3 months after intervention. RESULTS One month after intervention, VAS morning showed significant improvement in intervention group (P = 0.006) and RMS showed better improvement in intervention group (P = 0.026). There was no significant difference between the two groups after 3 months in RMS or VAS score. PF thickness was decreased significantly in both groups, but it was not significant between the two groups (P = 0.292). CONCLUSIONS This combinational therapy yielded earlier pain reduction and functional improvement than using shock wave alone; topical corticosteroid could enhance the effectiveness of shockwave in short-term in the treatment of recalcitrant plantar fasciitis.
Collapse
Affiliation(s)
- Babak Vahdatpour
- From the Department of Physical Medicine and Rehabilitation, Alzahra Hospital, Isfahan University of Medical Sciences, Isfahan, Iran
| | - Arghavan Mokhtarian
- From the Department of Physical Medicine and Rehabilitation, Alzahra Hospital, Isfahan University of Medical Sciences, Isfahan, Iran
| | - Seyed Ahmad Raeissadat
- Physical Medicine and Rehabilitation Research Center, School of Medicine, Shahid Modarres Hospital, Shahid Beheshti University of Medical Sciences, Tehran, Iran
| | - Farnaz Dehghan
- From the Department of Physical Medicine and Rehabilitation, Alzahra Hospital, Isfahan University of Medical Sciences, Isfahan, Iran
| | - Nafiseh Nasr
- Department of Radiology, Alzahra Hospital, Isfahan University of Medical Sciences, Isfahan, Iran
| | - Mahsa Mazaheri
- From the Department of Physical Medicine and Rehabilitation, Alzahra Hospital, Isfahan University of Medical Sciences, Isfahan, Iran
| |
Collapse
|
28
|
Kim WJ, Koo JH, Cho HJ, Lee JU, Kim JY, Lee HG, Lee S, Kim JH, Oh MS, Suh M, Shin EC, Ko JY, Sohn MH, Choi JM. Protein tyrosine phosphatase conjugated with a novel transdermal delivery peptide, astrotactin 1-derived peptide recombinant protein tyrosine phosphatase (AP-rPTP), alleviates both atopic dermatitis-like and psoriasis-like dermatitis. J Allergy Clin Immunol 2017; 141:137-151. [PMID: 28456618 DOI: 10.1016/j.jaci.2017.04.007] [Citation(s) in RCA: 14] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/20/2016] [Revised: 03/20/2017] [Accepted: 04/04/2017] [Indexed: 11/27/2022]
Abstract
BACKGROUND Atopic dermatitis (AD) and psoriasis are the 2 most common chronic inflammatory skin diseases. There is an unmet medical need to overcome limitations for transcutaneous drug development posed by the skin barrier. OBJECTIVE We aimed to identify a novel transdermal delivery peptide and to develop a transcutaneously applicable immunomodulatory protein for treating AD and psoriasis. METHODS We identified and generated reporter proteins conjugated to astrotactin 1-derived peptide (AP), a novel transdermal delivery peptide of human origin, and analyzed the intracellular delivery efficiency of these proteins in mouse and human skin cells and tissues using multiphoton confocal microscopy. We also generated a recombinant therapeutic protein, AP-recombinant protein tyrosine phosphatase (rPTP), consisting of the phosphatase domain of the T-cell protein tyrosine phosphatase conjugated to AP. The immunomodulatory function of AP-rPTP was confirmed in splenocytes on cytokine stimulation and T-cell receptor stimulation. Finally, we confirmed the in vivo efficacy of AP-rPTP transdermal delivery in patients with oxazolone-induced contact hypersensitivity, ovalbumin-induced AD-like, and imiquimod-induced psoriasis-like skin inflammation models. RESULTS AP-conjugated reporter proteins exhibited significant intracellular transduction efficacy in keratinocytes, fibroblasts, and immune cells. In addition, transcutaneous administration of AP-dTomato resulted in significant localization into the dermis and epidermis in both mouse and human skin. AP-rPTP inhibited phosphorylated signal transducer and activator of transcription (STAT) 1, STAT3, and STAT6 in splenocytes and also regulated T-cell activation and proliferation. Transcutaneous administration of AP-rPTP through the paper-patch technique significantly ameliorated skin tissue thickening, inflammation, and cytokine expression in both AD-like and psoriasis-like dermatitis models. CONCLUSION We identified a 9-amino-acid novel transdermal delivery peptide, AP, and demonstrated its feasibility for transcutaneous biologic drug development. Moreover, AP-rPTP is a novel immunomodulatory drug candidate for human dermatitis.
Collapse
Affiliation(s)
- Won-Ju Kim
- Department of Life Science, College of Natural Sciences, Hanyang University, Seoul, Korea; Research Institute for Natural Sciences, Hanyang University, Seoul, Korea
| | - Ja-Hyun Koo
- Department of Life Science, College of Natural Sciences, Hanyang University, Seoul, Korea; Research Institute for Natural Sciences, Hanyang University, Seoul, Korea
| | - Hyun-Jung Cho
- Department of Life Science, College of Natural Sciences, Hanyang University, Seoul, Korea; Research Institute for Natural Sciences, Hanyang University, Seoul, Korea
| | - Jae-Ung Lee
- Department of Life Science, College of Natural Sciences, Hanyang University, Seoul, Korea; Research Institute for Natural Sciences, Hanyang University, Seoul, Korea
| | - Ji Yun Kim
- Department of Life Science, College of Natural Sciences, Hanyang University, Seoul, Korea; Research Institute for Natural Sciences, Hanyang University, Seoul, Korea
| | - Hong-Gyun Lee
- Department of Life Science, College of Natural Sciences, Hanyang University, Seoul, Korea; Research Institute for Natural Sciences, Hanyang University, Seoul, Korea
| | - Sohee Lee
- Center for Neuroscience Imaging Research (CNIR), Institute for Basic Science (IBS), Suwon, Korea
| | - Jong Hoon Kim
- Laboratory of Immunology and Infectious Diseases, Graduate School of Medical Science and Engineering, Korea Advanced Institute of Science and Technology, Daejeon, Korea
| | - Mi Seon Oh
- Department of Pediatrics, Severance Hospital, Institute of Allergy, Brain Korea 21 PLUS Project for Medical Science, Yonsei University College of Medicine, Seoul, Korea
| | - Minah Suh
- Center for Neuroscience Imaging Research (CNIR), Institute for Basic Science (IBS), Suwon, Korea; Department of Biomedical Engineering, Sungkyunkwan University, Suwon, Korea; Samsung Advanced Institute for Health Sciences & Technology (SAIHST), Seoul, Korea
| | - Eui-Cheol Shin
- Laboratory of Immunology and Infectious Diseases, Graduate School of Medical Science and Engineering, Korea Advanced Institute of Science and Technology, Daejeon, Korea
| | - Joo Yeon Ko
- Department of Dermatology, College of Medicine, Hanyang University, Seoul, Korea
| | - Myung Hyun Sohn
- Department of Pediatrics, Severance Hospital, Institute of Allergy, Brain Korea 21 PLUS Project for Medical Science, Yonsei University College of Medicine, Seoul, Korea
| | - Je-Min Choi
- Department of Life Science, College of Natural Sciences, Hanyang University, Seoul, Korea; Research Institute for Natural Sciences, Hanyang University, Seoul, Korea; Center for Neuroscience Imaging Research (CNIR), Institute for Basic Science (IBS), Suwon, Korea.
| |
Collapse
|
29
|
Leelarungrayub J, Manorsoi J, Manorsoi A. Anti-inflammatory activity of niosomes entrapped with Plai oil ( Zingiber cassumunar Roxb.) by therapeutic ultrasound in a rat model. Int J Nanomedicine 2017; 12:2469-2476. [PMID: 28408818 PMCID: PMC5383072 DOI: 10.2147/ijn.s129131] [Citation(s) in RCA: 25] [Impact Index Per Article: 3.6] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/23/2022] Open
Abstract
OBJECTIVE The aim of this study was to evaluate the antioxidant and anti-inflammatory activities of Plai oil-encapsulated niosomes (Zingiber cassumunar Roxb.) on inflamed subcutaneous Wistar rat skin by therapeutic ultrasound. METHODS Pure oil from Plai rhizomes was extracted by steam distillation, and antioxidant activities were determined by 2,2-diphenyl-1-picrylhydrazyl radical scavenging assay. Bioactive compounds were analyzed by gas chromatography-mass spectrometry. Niosome particles containing Plai oil were prepared by chloroform film method with sonication before testing for anti-inflammatory activity on locally inflamed subcutaneous rat skin after inducement from lipopolysaccharide with ultrasound once a day for 3 days. Skin temperatures and blood flow were evaluated. RESULTS Plai oil presented antioxidant activity that inhibited 2,2-diphenyl-1-picrylhydrazyl radicals. Four active compounds found in the essential oil were sabinene, γ-terpinene, terpinene-4-ol, and (E)-1-(3,4-dimethyoxy phenyl) butadiene. Application of ultrasound (0.2 W/cm2, 20%, 3 min) with gel containing Plai oil-encapsulated niosomes decreased skin temperature and blood flow to the lowest level compared to the application of neurofen drug or gel-based control. CONCLUSION Plai oil, which consists of four main bioactive compounds and possesses antioxidant and anti-inflammatory activities, can be applied against local subcutaneous inflammation when used with therapeutic ultrasound via entrapped niosomes.
Collapse
Affiliation(s)
- Jirakrit Leelarungrayub
- Department of Physical Therapy, Faculty of Associated Medical Sciences, Chiang Mai University
| | - Jiradej Manorsoi
- Manose Health and Beauty Research Center, Mueng
- Division of Cosmetic Technology, Faculty of Science and Technology, North Chiang Mai University, Chiang Mai, Thailand
| | - Aranya Manorsoi
- Manose Health and Beauty Research Center, Mueng
- Division of Cosmetic Technology, Faculty of Science and Technology, North Chiang Mai University, Chiang Mai, Thailand
| |
Collapse
|
30
|
ÜNAL M, Durmus D. Diz Osteoartritinde Kapsaisin Fonoforezin Etkisi ve Birinci Basamakta Erken Kullanılabilirliği: Randomize Kontrollü Bir Çalısma. KONURALP TIP DERGISI 2016. [DOI: 10.18521/ktd.284442] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/04/2022]
|
31
|
Chan KOW, Tong HHY, Ng GYF. Topical Fish Oil Application Coupling with Therapeutic Ultrasound Improves Tendon Healing. ULTRASOUND IN MEDICINE & BIOLOGY 2016; 42:2983-2989. [PMID: 27692307 DOI: 10.1016/j.ultrasmedbio.2016.08.018] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 01/19/2016] [Revised: 08/10/2016] [Accepted: 08/12/2016] [Indexed: 06/06/2023]
Abstract
Fish oil has been shown to promote collagen synthesis, and hence, connective tissue healing. Therapeutic ultrasound is commonly used to treat soft tissue injuries. This study aimed to investigate the therapeutic effect of topical fish oil on the management of Achilles tendon rupture, comparing normal therapeutic ultrasound with a combination of ultrasound and fish oil. Eighty-five Sprague-Dawley rats underwent surgical hemitenotomy of the right medial Achilles tendon. The rats received daily treatment of either topical placebo ointment (control group [CON]), topical fish oil (FO), therapeutic ultrasound (US) or ultrasound with fish oil as the coupling medium (FU). The treatment started on post-surgical day 2 over a 2-wk or 4-wk period. On days 15 and 29, the rats were sacrificed and their Achilles tendons were tested for structural stiffness, ultimate tensile strength (UTS) and energy absorption capacity. At 2 wk, only US showed higher normalized UTS compared with CON (p < 0.05). At 4 wk, both US and FU demonstrated better UTS (p < 0.05), while both FO and FU had improved in structural stiffness (p < 0.05). Four wk of treatment with ultrasound using fish oil as coupling medium showed improvement in both structural stiffness and UTS (p < 0.05).
Collapse
Affiliation(s)
- Karly O W Chan
- Department of Rehabilitation Sciences, The Hong Kong Polytechnic University, Hong Kong SAR, China.
| | - Henry H Y Tong
- School of Health Sciences, Macao Polytechnic Institute, Macau SAR, China
| | - Gabriel Y F Ng
- Department of Rehabilitation Sciences, The Hong Kong Polytechnic University, Hong Kong SAR, China
| |
Collapse
|
32
|
Guirro ECDO, Angelis DDFD, Sousa NTAD, Guirro RRDJ. Combination of therapeutic ultrasound with antibiotics interfere with the growth of bacterial culture that colonizes skin ulcers: An in-vitro study. ULTRASONICS SONOCHEMISTRY 2016; 32:284-289. [PMID: 27150772 DOI: 10.1016/j.ultsonch.2016.03.024] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 04/14/2015] [Revised: 03/22/2016] [Accepted: 03/23/2016] [Indexed: 06/05/2023]
Abstract
Staphylococcus aureus and Escherichia coli are among the major bacterial species that colonize skin ulcers. Therapeutic ultrasound (TUS) produces biophysical effects that are relevant to wound healing; however, its application over a contaminated injury is not evidence-based. The objective of this research was to analyze the effect of TUS on in vitro-isolated S. aureus and E. coli, including the combination of ultrasound and antibiotics, in order to assess their antibiotic action on bacterial susceptibility. For the experiments, the bacterial strains were suspended in saline, then diluted (10(4)CFU/mL) for irradiation (at 1 and 3MHz, 0.5 and 0.8W/cm(2) for 0 and 15min) and the combination treatment of ultrasonication and antibiotics was administered by adding nalidixic acid (S. aureus) and tetracycline (E. coli) at concentrations equivalent to 50% of the minimum inhibitory concentration (MIC). The experiments were carried out in duplicate with six repetitions. The suspensions were inoculated on to Petri plates and incubated at 37°C and the colony forming units (CFUs) were counted after 24h. The results were subjected to the Shapiro-Wilk normality test, followed by parametric ANOVA and Tukey's post hoc test at a significance level of 1%. The results demonstrated that the action of TUS at 1MHz inhibited bacterial growth while at 3MHz, bacterial growth was observed in both species. However, the synergistic combination of ultrasound and antibiotics was able to inhibit the growth of both bacteria completely after 15min of ultrasonication. The results suggest that the action of ultrasound on S. aureus and E. coli are dependent on the oscillation frequency as well as the intensity and time of application. The combination of ultrasound with antibiotics was able to inhibit bacterial growth fully at all frequencies and doses in both species.
Collapse
Affiliation(s)
- Elaine Caldeira de Oliveira Guirro
- Department of Biomechanics, Medicine and Rehabilitation of the Locomotor System, Laboratory of Physiotherapeutic Resources, Ribeirão Preto Medical School of University of São Paulo, Ribeirão Preto, SP, Brazil.
| | - Dejanira de Franceschi de Angelis
- Department of Biochemistry and Microbiology, Institute of Biosciences of Rio Claro of Paulista State University, Rio Claro, SP, Brazil
| | - Natanael Teixeira Alves de Sousa
- Post-Graduation Program in Rehabilitation and Performance Functional, Ribeirão Preto Medical School of University of São Paulo, Ribeirão Preto, SP, Brazil
| | - Rinaldo Roberto de Jesus Guirro
- Department of Biomechanics, Medicine and Rehabilitation of the Locomotor System, Laboratory of Physiotherapeutic Resources, Ribeirão Preto Medical School of University of São Paulo, Ribeirão Preto, SP, Brazil
| |
Collapse
|
33
|
Van Der Bijl P, Basson E, Van Eyk A, Seifart H. Effect of Ultrasound on Transdermal Permeation of Diclofenac. EUR J INFLAMM 2016. [DOI: 10.1177/1721727x0600400205] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/16/2022] Open
Abstract
During the last two decades the effects of ultrasound on the transdermal permeability to a wide variety of drugs have been extensively investigated. There is still some uncertainty regarding the mechanisms involved in ultrasonic permeation enhancement, thus we investigated the effect of ultrasonic treatment on the transdermal permeation of the NSAID, diclofenac. Experiments were conducted over two phases, consisting of different time periods, using a continuous flow-through diffusion system. It is clear from the present study that ultrasound enhanced the permeability of human skin to diclofenac released from a commercially available gel. These results were in contrast to those obtained for ibuprofen in an in vitro study across human skin, but in agreement with those obtained in two in vivo studies of the latter NSAID. Steady state flux values of diclofenac remained approximately 1.26 times higher than those of controls during the 24 h of the experiment. These observations concurred with those made in two previous in vivo studies. It was concluded that the enhancement of diclofenac permeation by sonication could not be adequately explained primarily on a thermal basis. Furthermore, the in vitro flow-through diffusion model was shown to have predictive value as an in vivo method for sonophoresis.
Collapse
Affiliation(s)
- P. Van Der Bijl
- Department of Pharmacology, Faculty of Health Sciences, Stellenbosch University, Tygerberg, South Africa
| | - E. Basson
- Department of Pharmacology, Faculty of Health Sciences, Stellenbosch University, Tygerberg, South Africa
| | - A.D. Van Eyk
- Department of Pharmacology, Faculty of Health Sciences, Stellenbosch University, Tygerberg, South Africa
| | - H.I. Seifart
- Department of Pharmacology, Faculty of Health Sciences, Stellenbosch University, Tygerberg, South Africa
| |
Collapse
|
34
|
Page MJ, Green S, Mrocki MA, Surace SJ, Deitch J, McBain B, Lyttle N, Buchbinder R. Electrotherapy modalities for rotator cuff disease. Cochrane Database Syst Rev 2016; 2016:CD012225. [PMID: 27283591 PMCID: PMC8570637 DOI: 10.1002/14651858.cd012225] [Citation(s) in RCA: 42] [Impact Index Per Article: 5.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/08/2022]
Abstract
BACKGROUND Management of rotator cuff disease may include use of electrotherapy modalities (also known as electrophysical agents), which aim to reduce pain and improve function via an increase in energy (electrical, sound, light, or thermal) into the body. Examples include therapeutic ultrasound, low-level laser therapy (LLLT), transcutaneous electrical nerve stimulation (TENS), and pulsed electromagnetic field therapy (PEMF). These modalities are usually delivered as components of a physical therapy intervention. This review is one of a series of reviews that form an update of the Cochrane review, 'Physiotherapy interventions for shoulder pain'. OBJECTIVES To synthesise available evidence regarding the benefits and harms of electrotherapy modalities for the treatment of people with rotator cuff disease. SEARCH METHODS We searched the Cochrane Central Register of Controlled Trials (CENTRAL; 2015, Issue 3), Ovid MEDLINE (January 1966 to March 2015), Ovid EMBASE (January 1980 to March 2015), CINAHL Plus (EBSCOhost, January 1937 to March 2015), ClinicalTrials.gov and the WHO ICTRP clinical trials registries up to March 2015, unrestricted by language, and reviewed the reference lists of review articles and retrieved trials, to identify potentially relevant trials. SELECTION CRITERIA We included randomised controlled trials (RCTs) and quasi-randomised trials, including adults with rotator cuff disease (e.g. subacromial impingement syndrome, rotator cuff tendinitis, calcific tendinitis), and comparing any electrotherapy modality with placebo, no intervention, a different electrotherapy modality or any other intervention (e.g. glucocorticoid injection). Trials investigating whether electrotherapy modalities were more effective than placebo or no treatment, or were an effective addition to another physical therapy intervention (e.g. manual therapy or exercise) were the main comparisons of interest. Main outcomes of interest were overall pain, function, pain on motion, patient-reported global assessment of treatment success, quality of life and the number of participants experiencing adverse events. DATA COLLECTION AND ANALYSIS Two review authors independently selected trials for inclusion, extracted the data, performed a risk of bias assessment and assessed the quality of the body of evidence for the main outcomes using the GRADE approach. MAIN RESULTS We included 47 trials (2388 participants). Most trials (n = 43) included participants with rotator cuff disease without calcification (four trials included people with calcific tendinitis). Sixteen (34%) trials investigated the effect of an electrotherapy modality delivered in isolation. Only 23% were rated at low risk of allocation bias, and 49% were rated at low risk of both performance and detection bias (for self-reported outcomes). The trials were heterogeneous in terms of population, intervention and comparator, so none of the data could be combined in a meta-analysis.In one trial (61 participants; low quality evidence), pulsed therapeutic ultrasound (three to five times a week for six weeks) was compared with placebo (inactive ultrasound therapy) for calcific tendinitis. At six weeks, the mean reduction in overall pain with placebo was -6.3 points on a 52-point scale, and -14.9 points with ultrasound (MD -8.60 points, 95% CI -13.48 to -3.72 points; absolute risk difference 17%, 7% to 26% more). Mean improvement in function with placebo was 3.7 points on a 100-point scale, and 17.8 points with ultrasound (mean difference (MD) 14.10 points, 95% confidence interval (CI) 5.39 to 22.81 points; absolute risk difference 14%, 5% to 23% more). Ninety-one per cent (29/32) of participants reported treatment success with ultrasound compared with 52% (15/29) of participants receiving placebo (risk ratio (RR) 1.75, 95% CI 1.21 to 2.53; absolute risk difference 39%, 18% to 60% more). Mean improvement in quality of life with placebo was 0.40 points on a 10-point scale, and 2.60 points with ultrasound (MD 2.20 points, 95% CI 0.91 points to 3.49 points; absolute risk difference 22%, 9% to 35% more). Between-group differences were not important at nine months. No participant reported adverse events.Therapeutic ultrasound produced no clinically important additional benefits when combined with other physical therapy interventions (eight clinically heterogeneous trials, low quality evidence). We are uncertain whether there are differences in patient-important outcomes between ultrasound and other active interventions (manual therapy, acupuncture, glucocorticoid injection, glucocorticoid injection plus oral tolmetin sodium, or exercise) because the quality of evidence is very low. Two placebo-controlled trials reported results favouring LLLT up to three weeks (low quality evidence), however combining LLLT with other physical therapy interventions produced few additional benefits (10 clinically heterogeneous trials, low quality evidence). We are uncertain whether transcutaneous electrical nerve stimulation (TENS) is more or less effective than glucocorticoid injection with respect to pain, function, global treatment success and active range of motion because of the very low quality evidence from a single trial. In other single, small trials, no clinically important benefits of pulsed electromagnetic field therapy (PEMF), microcurrent electrical stimulation (MENS), acetic acid iontophoresis and microwave diathermy were observed (low or very low quality evidence).No adverse events of therapeutic ultrasound, LLLT, TENS or microwave diathermy were reported by any participants. Adverse events were not measured in any trials investigating the effects of PEMF, MENS or acetic acid iontophoresis. AUTHORS' CONCLUSIONS Based on low quality evidence, therapeutic ultrasound may have short-term benefits over placebo in people with calcific tendinitis, and LLLT may have short-term benefits over placebo in people with rotator cuff disease. Further high quality placebo-controlled trials are needed to confirm these results. In contrast, based on low quality evidence, PEMF may not provide clinically relevant benefits over placebo, and therapeutic ultrasound, LLLT and PEMF may not provide additional benefits when combined with other physical therapy interventions. We are uncertain whether TENS is superior to placebo, and whether any electrotherapy modality provides benefits over other active interventions (e.g. glucocorticoid injection) because of the very low quality of the evidence. Practitioners should communicate the uncertainty of these effects and consider other approaches or combinations of treatment. Further trials of electrotherapy modalities for rotator cuff disease should be based upon a strong rationale and consideration of whether or not they would alter the conclusions of this review.
Collapse
Affiliation(s)
- Matthew J Page
- Monash UniversitySchool of Public Health & Preventive MedicineLevel 1, 549 St Kilda RoadMelbourneVictoriaAustralia3004
| | - Sally Green
- School of Public Health & Preventive Medicine, Monash UniversityAustralasian Cochrane CentreLevel 1, 549 St Kilda RoadMelbourneVictoriaAustralia3004
| | - Marshall A Mrocki
- Department of Epidemiology and Preventive Medicine, School of Public Health and Preventive Medicine, Monash UniversityMonash Department of Clinical Epidemiology, Cabrini HospitalSuite 41, Cabrini Medical Centre183 Wattletree RoadMalvernVictoriaAustralia3144
| | | | | | - Brodwen McBain
- Melbourne Hand RehabSuite 3, 20 Commercial RoadMelbourneVictoriaAustralia3000
| | - Nicolette Lyttle
- Department of Epidemiology and Preventive Medicine, School of Public Health and Preventive Medicine, Monash UniversityMonash Department of Clinical Epidemiology, Cabrini HospitalSuite 41, Cabrini Medical Centre183 Wattletree RoadMalvernVictoriaAustralia3144
| | - Rachelle Buchbinder
- Department of Epidemiology and Preventive Medicine, School of Public Health and Preventive Medicine, Monash UniversityMonash Department of Clinical Epidemiology, Cabrini HospitalSuite 41, Cabrini Medical Centre183 Wattletree RoadMalvernVictoriaAustralia3144
| | | |
Collapse
|
35
|
Aghazadeh-Habashi A, Yang Y, Tang K, Lőbenberg R, Doschak MR. Transdermal drug delivery: feasibility for treatment of superficial bone stress fractures. Drug Deliv Transl Res 2015; 5:540-51. [DOI: 10.1007/s13346-015-0257-8] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/30/2023]
|
36
|
Ultrasound-enhanced transdermal delivery: recent advances and future challenges. Ther Deliv 2015; 5:843-57. [PMID: 25287389 DOI: 10.4155/tde.14.32] [Citation(s) in RCA: 47] [Impact Index Per Article: 5.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/17/2022] Open
Abstract
The skin is a formidable diffusion barrier that restricts passive diffusion to small (<500 Da) lipophilic molecules. Methods used to permeabilize this barrier for the purpose of drug delivery are maturing as an alternative to oral drug delivery and hypodermic injections. Ultrasound can reversibly and non-invasively permeabilize the diffusion barrier posed by the skin. This review discusses the mechanisms of ultrasound-permeability enhancement, and presents technological innovations in equipment miniaturization and recent advances in permeabilization capabilities. Additionally, potentially exciting applications, including protein delivery, vaccination, gene therapy and sensing of blood analytes, are discussed. Finally, the future challenges and opportunities associated with the use of ultrasound are discussed. It is stressed that developing ultrasound for suitable applications is key to ensure commercial success.
Collapse
|
37
|
Lee KL, Zhou Y. Quantitative evaluation of sonophoresis efficiency and its dependence on sonication parameters and particle size. JOURNAL OF ULTRASOUND IN MEDICINE : OFFICIAL JOURNAL OF THE AMERICAN INSTITUTE OF ULTRASOUND IN MEDICINE 2015; 34:519-526. [PMID: 25715372 DOI: 10.7863/ultra.34.3.519] [Citation(s) in RCA: 10] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/04/2023]
Abstract
Transdermal drug delivery makes a critical contribution to medical practice and some advantages over conventional oral administration and hypodermic injection. Enhancement of percutaneous absorption or penetration of therapeutic agents (ie, drugs and macromolecules) by ultrasound, termed sonophoresis, has been applied and studied for decades. In this study, the penetration percentage through porcine ear skin specimens was determined quantitatively by measuring the fluorescence from nanoparticles of 60, 220, and 840 nm in size in a receptor chamber at different sonication parameters (ie, duty cycle, 20%-100%; acoustic intensity, 0.3-1.0 W/cm(2); duration, 7-30 minutes; and frequency, 1 MHz). In general, the sonophoresis efficiency increased with the acoustic intensity, duty cycle, and sonication duration but decreased with the particle size (mean ± SD, 62.6% ± 5.4% for 60-nm versus 11.9% ± 1.1% for 840-nm polystyrene nanospheres after 30 minutes of sonication at 0.5 W/cm(2) and a 100% duty cycle; P < .05). On scanning electron microscopy the pore size remained the same (≈100 μm), but more flakes were observed with the progress of sonication. In summary, sonophoresis efficiency is dependent on the ultrasound parameters and particle size. Sufficient sonication would lead to satisfactory penetration of even submicrometer objects through the pores.
Collapse
Affiliation(s)
- Kun Loong Lee
- Division of Engineering Mechanics, School of Mechanical and Aerospace Engineering, Nanyang Technological University, Singapore (K.L.L., Y.Z.); and Key Laboratory of Modern Acoustics, Nanjing University, Nanjing, China (Y.Z.)
| | - Yufeng Zhou
- Division of Engineering Mechanics, School of Mechanical and Aerospace Engineering, Nanyang Technological University, Singapore (K.L.L., Y.Z.); and Key Laboratory of Modern Acoustics, Nanjing University, Nanjing, China (Y.Z.).
| |
Collapse
|
38
|
Duscher D, Neofytou E, Wong VW, Maan ZN, Rennert RC, Inayathullah M, Januszyk M, Rodrigues M, Malkovskiy AV, Whitmore AJ, Walmsley GG, Galvez MG, Whittam AJ, Brownlee M, Rajadas J, Gurtner GC. Transdermal deferoxamine prevents pressure-induced diabetic ulcers. Proc Natl Acad Sci U S A 2015; 112:94-9. [PMID: 25535360 PMCID: PMC4291638 DOI: 10.1073/pnas.1413445112] [Citation(s) in RCA: 132] [Impact Index Per Article: 14.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/13/2022] Open
Abstract
There is a high mortality in patients with diabetes and severe pressure ulcers. For example, chronic pressure sores of the heels often lead to limb loss in diabetic patients. A major factor underlying this is reduced neovascularization caused by impaired activity of the transcription factor hypoxia inducible factor-1 alpha (HIF-1α). In diabetes, HIF-1α function is compromised by a high glucose-induced and reactive oxygen species-mediated modification of its coactivator p300, leading to impaired HIF-1α transactivation. We examined whether local enhancement of HIF-1α activity would improve diabetic wound healing and minimize the severity of diabetic ulcers. To improve HIF-1α activity we designed a transdermal drug delivery system (TDDS) containing the FDA-approved small molecule deferoxamine (DFO), an iron chelator that increases HIF-1α transactivation in diabetes by preventing iron-catalyzed reactive oxygen stress. Applying this TDDS to a pressure-induced ulcer model in diabetic mice, we found that transdermal delivery of DFO significantly improved wound healing. Unexpectedly, prophylactic application of this transdermal delivery system also prevented diabetic ulcer formation. DFO-treated wounds demonstrated increased collagen density, improved neovascularization, and reduction of free radical formation, leading to decreased cell death. These findings suggest that transdermal delivery of DFO provides a targeted means to both prevent ulcer formation and accelerate diabetic wound healing with the potential for rapid clinical translation.
Collapse
Affiliation(s)
- Dominik Duscher
- Hagey Laboratory for Pediatric Regenerative Medicine, Division of Plastic and Reconstructive Surgery, Department of Surgery, Stanford University School of Medicine, Stanford, CA 94305
| | - Evgenios Neofytou
- Hagey Laboratory for Pediatric Regenerative Medicine, Division of Plastic and Reconstructive Surgery, Department of Surgery, Stanford University School of Medicine, Stanford, CA 94305
| | - Victor W Wong
- Department of Plastic Surgery, Johns Hopkins University School of Medicine, Baltimore, MD 21201
| | - Zeshaan N Maan
- Hagey Laboratory for Pediatric Regenerative Medicine, Division of Plastic and Reconstructive Surgery, Department of Surgery, Stanford University School of Medicine, Stanford, CA 94305
| | - Robert C Rennert
- Hagey Laboratory for Pediatric Regenerative Medicine, Division of Plastic and Reconstructive Surgery, Department of Surgery, Stanford University School of Medicine, Stanford, CA 94305
| | - Mohammed Inayathullah
- Biomaterials and Advanced Drug Delivery Center, Stanford University School of Medicine, Stanford, CA 94305; and
| | - Michael Januszyk
- Hagey Laboratory for Pediatric Regenerative Medicine, Division of Plastic and Reconstructive Surgery, Department of Surgery, Stanford University School of Medicine, Stanford, CA 94305
| | - Melanie Rodrigues
- Hagey Laboratory for Pediatric Regenerative Medicine, Division of Plastic and Reconstructive Surgery, Department of Surgery, Stanford University School of Medicine, Stanford, CA 94305
| | - Andrey V Malkovskiy
- Biomaterials and Advanced Drug Delivery Center, Stanford University School of Medicine, Stanford, CA 94305; and
| | - Arnetha J Whitmore
- Hagey Laboratory for Pediatric Regenerative Medicine, Division of Plastic and Reconstructive Surgery, Department of Surgery, Stanford University School of Medicine, Stanford, CA 94305
| | - Graham G Walmsley
- Hagey Laboratory for Pediatric Regenerative Medicine, Division of Plastic and Reconstructive Surgery, Department of Surgery, Stanford University School of Medicine, Stanford, CA 94305
| | - Michael G Galvez
- Hagey Laboratory for Pediatric Regenerative Medicine, Division of Plastic and Reconstructive Surgery, Department of Surgery, Stanford University School of Medicine, Stanford, CA 94305
| | - Alexander J Whittam
- Hagey Laboratory for Pediatric Regenerative Medicine, Division of Plastic and Reconstructive Surgery, Department of Surgery, Stanford University School of Medicine, Stanford, CA 94305
| | - Michael Brownlee
- Diabetes Research Center, Albert Einstein College of Medicine, New York, NY 10461
| | - Jayakumar Rajadas
- Biomaterials and Advanced Drug Delivery Center, Stanford University School of Medicine, Stanford, CA 94305; and
| | - Geoffrey C Gurtner
- Hagey Laboratory for Pediatric Regenerative Medicine, Division of Plastic and Reconstructive Surgery, Department of Surgery, Stanford University School of Medicine, Stanford, CA 94305;
| |
Collapse
|
39
|
Page MJ, Green S, Kramer S, Johnston RV, McBain B, Buchbinder R. Electrotherapy modalities for adhesive capsulitis (frozen shoulder). Cochrane Database Syst Rev 2014; 2014:CD011324. [PMID: 25271097 PMCID: PMC10898218 DOI: 10.1002/14651858.cd011324] [Citation(s) in RCA: 46] [Impact Index Per Article: 4.6] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 12/31/2022]
Abstract
BACKGROUND Adhesive capsulitis (also termed frozen shoulder) is a common condition characterised by spontaneous onset of pain, progressive restriction of movement of the shoulder and disability that restricts activities of daily living, work and leisure. Electrotherapy modalities, which aim to reduce pain and improve function via an increase in energy (electrical, sound, light, thermal) into the body, are often delivered as components of a physical therapy intervention. This review is one in a series of reviews which form an update of the Cochrane review 'Physiotherapy interventions for shoulder pain'. OBJECTIVES To synthesise the available evidence regarding the benefits and harms of electrotherapy modalities, delivered alone or in combination with other interventions, for the treatment of adhesive capsulitis. SEARCH METHODS We searched CENTRAL, MEDLINE, EMBASE, CINAHL Plus and the ClinicalTrials.gov and World Health Organization (WHO) International Clinical Trials Registry Platform (ICTRP) clinical trials registries up to May 2014, unrestricted by language, and reviewed the reference lists of review articles and retrieved trials to identify any other potentially relevant trials. SELECTION CRITERIA We included randomised controlled trials (RCTs) and controlled clinical trials using a quasi-randomised method of allocation that included adults with adhesive capsulitis and compared any electrotherapy modality to placebo, no treatment, a different electrotherapy modality, or any other intervention. The two main questions of the review focused on whether electrotherapy modalities are effective compared to placebo or no treatment, or if they are an effective adjunct to manual therapy or exercise (or both). The main outcomes of interest were participant-reported pain relief of 30% or greater, overall pain, function, global assessment of treatment success, active shoulder abduction, quality of life, and the number of participants experiencing any adverse event. DATA COLLECTION AND ANALYSIS Two review authors independently selected trials for inclusion, extracted the data, performed a risk of bias assessment, and assessed the quality of the body of evidence for the main outcomes using the GRADE approach. MAIN RESULTS Nineteen trials (1249 participants) were included in the review. Four trials reported using an adequate method of allocation concealment and six trials blinded participants and personnel. Only two electrotherapy modalities (low-level laser therapy (LLLT) and pulsed electromagnetic field therapy (PEMF)) have been compared to placebo. No trial has compared an electrotherapy modality plus manual therapy and exercise to manual therapy and exercise alone. The two main questions of the review were investigated in nine trials.Low quality evidence from one trial (40 participants) indicated that LLLT for six days may result in improvement at six days. Eighty per cent (16/20) of participants reported treatment success with LLLT compared with 10% (2/20) of participants receiving placebo (risk ratio (RR) 8.00, 95% confidence interval (CI) 2.11 to 30.34; absolute risk difference 70%, 95% CI 48% to 92%). No participants in either group reported adverse events.We were uncertain whether PEMF for two weeks improved pain or function more than placebo at two weeks because of the very low quality evidence from one trial (32 participants). Seventy-five per cent (15/20) of participants reported pain relief of 30% or more with PEMF compared with 0% (0/12) of participants receiving placebo (RR 19.19, 95% CI 1.25 to 294.21; absolute risk difference 75%, 95% CI 53% to 97%). Fifty-five per cent (11/20) of participants reported total recovery of joint function with PEMF compared with 0% (0/12) of participants receiving placebo (RR 14.24, 95% CI 0.91 to 221.75; absolute risk difference 55%, 95% CI 31 to 79).Moderate quality evidence from one trial (63 participants) indicated that LLLT plus exercise for eight weeks probably results in greater improvement when measured at the fourth week of treatment, but a similar number of adverse events, compared with placebo plus exercise. The mean pain score at four weeks was 51 points with placebo plus exercise, while with LLLT plus exercise the mean pain score was 32 points on a 100 point scale (mean difference (MD) 19 points, 95% CI 15 to 23; absolute risk difference 19%, 95% CI 15% to 23%). The mean function impairment score was 48 points with placebo plus exercise, while with LLLT plus exercise the mean function impairment score was 36 points on a 100 point scale (MD 12 points, 95% CI 6 to 18; absolute risk difference 12%, 95% CI 6 to 18). Mean active abduction was 70 degrees with placebo plus exercise, while with LLLT plus exercise mean active abduction was 79 degrees (MD 9 degrees, 95% CI 2 to 16; absolute risk difference 5%, 95% CI 1% to 9%). No participants in either group reported adverse events. LLLT's benefits on function were maintained at four months.Based on very low quality evidence from six trials, we were uncertain whether therapeutic ultrasound, PEMF, continuous short wave diathermy, Iodex phonophoresis, a combination of Iodex iontophoresis with continuous short wave diathermy, or a combination of therapeutic ultrasound with transcutaneous electrical nerve stimulation (TENS) were effective adjuncts to exercise. Based on low or very low quality evidence from 12 trials, we were uncertain whether a diverse range of electrotherapy modalities (delivered alone or in combination with manual therapy, exercise, or other active interventions) were more or less effective than other active interventions (for example glucocorticoid injection). AUTHORS' CONCLUSIONS Based upon low quality evidence from one trial, LLLT for six days may be more effective than placebo in terms of global treatment success at six days. Based upon moderate quality evidence from one trial, LLLT plus exercise for eight weeks may be more effective than exercise alone in terms of pain up to four weeks, and function up to four months. It is unclear whether PEMF is more or less effective than placebo, or whether other electrotherapy modalities are an effective adjunct to exercise. Further high quality randomised controlled trials are needed to establish the benefits and harms of physical therapy interventions (that comprise electrotherapy modalities, manual therapy and exercise, and are reflective of clinical practice) compared to interventions with evidence of benefit (for example glucocorticoid injection or arthrographic joint distension).
Collapse
Affiliation(s)
- Matthew J Page
- Monash UniversitySchool of Public Health & Preventive MedicineThe Alfred Centre99 Commercial RoadMelbourneVictoriaAustralia3004
| | - Sally Green
- Monash UniversitySchool of Public Health & Preventive MedicineThe Alfred Centre99 Commercial RoadMelbourneVictoriaAustralia3004
| | - Sharon Kramer
- Monash UniversitySchool of Public Health & Preventive MedicineThe Alfred Centre99 Commercial RoadMelbourneVictoriaAustralia3004
| | - Renea V Johnston
- Department of Epidemiology and Preventive Medicine, School of Public Health and Preventive Medicine, Monash UniversityMonash Department of Clinical Epidemiology, Cabrini Hospital154 Wattletree RoadMalvernVictoriaAustralia3144
| | - Brodwen McBain
- Melbourne Hand RehabSuite 3, 20 Commercial RoadMelbourneVictoriaAustralia3000
| | - Rachelle Buchbinder
- Department of Epidemiology and Preventive Medicine, School of Public Health and Preventive Medicine, Monash UniversityMonash Department of Clinical Epidemiology, Cabrini Hospital154 Wattletree RoadMalvernVictoriaAustralia3144
| | | |
Collapse
|
40
|
A randomized placebo-controlled clinical trial of phonophoresis for the treatment of chronic neck pain. Rheumatol Int 2013; 34:605-11. [DOI: 10.1007/s00296-013-2928-4] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/03/2013] [Accepted: 12/14/2013] [Indexed: 10/25/2022]
|
41
|
Souza J, Meira A, Volpato NM, Mayorga P, Gottfried C. Effect of phonophoresis on skin permeation of commercial anti-inflammatory gels: sodium diclofenac and ketoprofen. ULTRASOUND IN MEDICINE & BIOLOGY 2013; 39:1623-1630. [PMID: 23820249 DOI: 10.1016/j.ultrasmedbio.2013.02.009] [Citation(s) in RCA: 10] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 07/18/2012] [Revised: 02/15/2013] [Accepted: 02/16/2013] [Indexed: 06/02/2023]
Abstract
This study evaluated the use of ultrasound in combination with the commercial anti-inflammatory drugs ketoprofen and sodium diclofenac, according to the parameters used in physiotherapy. Ketoprofen and sodium diclofenac were used in the Franz diffusion cell model adapted to an ultrasound transducer in three conditions: no ultrasound, one application of ultrasound and two applications of ultrasound. High-performance liquid chromatography was used to quantify the total amount of drug permeating skin per unit area, as well as flux and latency. The results showed that for ketoprofen, the amount of drug permeating skin and flux increased with two ultrasound applications. Permeation of sodium diclofenac decreased in the presence of ultrasound. Ultrasound parameters and drug properties must be considered in the use of phonophoresis.
Collapse
Affiliation(s)
- Jaqueline Souza
- Department of Biochemistry, Institute of Health's Basic Science, Federal University of Rio Grande do Sul, Porto Alegre, RS, Brazil.
| | | | | | | | | |
Collapse
|
42
|
Durmus D, Alayli G, Goktepe AS, Taskaynatan MA, Bilgici A, Kuru O. Is phonophoresis effective in the treatment of chronic low back pain? A single-blind randomized controlled trial. Rheumatol Int 2013; 33:1737-44. [DOI: 10.1007/s00296-012-2634-7] [Citation(s) in RCA: 7] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/18/2012] [Accepted: 12/15/2012] [Indexed: 10/27/2022]
|
43
|
Lewis GK, Schulz ZR, Pannullo SC, Southard TL, Olbricht WL. Ultrasound-assisted convection-enhanced delivery to the brain in vivo with a novel transducer cannula assembly: laboratory investigation. J Neurosurg 2012; 117:1128-40. [PMID: 22998056 DOI: 10.3171/2012.7.jns11144] [Citation(s) in RCA: 17] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/06/2022]
Abstract
OBJECT In convection-enhanced delivery (CED), drugs are infused locally into tissue through a cannula inserted into the brain parenchyma to enhance drug penetration over diffusion strategies. The purpose of this study was to demonstrate the feasibility of ultrasound-assisted CED (UCED) in the rodent brain in vivo using a novel, low-profile transducer cannula assembly (TCA) and portable, pocket-sized ultrasound system. METHODS Forty Sprague-Dawley rats (350-450 g) were divided into 2 equal groups (Groups 1 and 2). Each group was divided again into 4 subgroups (n = 5 in each). The caudate of each rodent brain was infused with 0.25 wt% Evans blue dye (EBD) in phosphate-buffered saline at 2 different infusion rates of 0.25 μl/minute (Group 1), and 0.5 μl/minute (Group 2). The infusion rates were increased slowly over 10 minutes from 0.05 to 0.25 μl/minute (Group 1) and from 0.1 to 0.5 μl/minute (Group 2). The final flow rate was maintained for 20 minutes. Rodents in the 4 control subgroups were infused using the TCA without ultrasound and without and with microbubbles added to the infusate (CED and CED + MB, respectively). Rodents in the 4 UCED subgroups were infused without and with microbubbles added to the infusate (UCED and UCED + MB) using the TCA with continuous-wave 1.34-MHz low-intensity ultrasound at a total acoustic power of 0.11 ± 0.005 W and peak spatial intensity at the cannula tip of 49.7 mW/cm(2). An additional 4 Sprague-Dawley rats (350-450 g) received UCED at 4 different and higher ultrasound intensities at the cannula tip ranging from 62.0 to 155.0 mW/cm(2) for 30 minutes. The 3D infusion distribution was reconstructed using MATLAB analysis. Tissue damage and morphological changes to the brain were assessed using H & E. RESULTS The application of ultrasound during infusion (UCED and UCED + MB) improved the volumetric distribution of EBD in the brain by a factor of 2.24 to 3.25 when there were no microbubbles in the infusate and by a factor of 1.16 to 1.70 when microbubbles were added to the infusate (p < 0.001). On gross and histological examination, no damage to the brain tissue was found for any acoustic exposure applied to the brain. CONCLUSIONS The TCA and ultrasound device show promise to improve the distribution of infused compounds during CED. The results suggest further studies are required to optimize infusion and acoustic parameters for small compounds and for larger molecular weight compounds that are representative of promising antitumor agents. In addition, safe levels of ultrasound exposure in chronic experiments must be determined for practical clinical evaluation of UCED. Extension of these experiments to larger animal models is warranted to demonstrate efficacy of this technique.
Collapse
Affiliation(s)
- George K Lewis
- Department of Biomedical Engineering, Cornell University, Ithaca, New York, USA.
| | | | | | | | | |
Collapse
|
44
|
Miller DL, Smith NB, Bailey MR, Czarnota GJ, Hynynen K, Makin IRS. Overview of therapeutic ultrasound applications and safety considerations. JOURNAL OF ULTRASOUND IN MEDICINE : OFFICIAL JOURNAL OF THE AMERICAN INSTITUTE OF ULTRASOUND IN MEDICINE 2012; 31:623-34. [PMID: 22441920 PMCID: PMC3810427 DOI: 10.7863/jum.2012.31.4.623] [Citation(s) in RCA: 331] [Impact Index Per Article: 27.6] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/05/2023]
Abstract
Applications of ultrasound in medicine for therapeutic purposes have been accepted and beneficial uses of ultrasonic biological effects for many years. Low-power ultrasound of about 1 MHz has been widely applied since the 1950s for physical therapy in conditions such as tendinitis and bursitis. In the 1980s, high-pressure-amplitude shock waves came into use for mechanically resolving kidney stones, and "lithotripsy" rapidly replaced surgery as the most frequent treatment choice. The use of ultrasonic energy for therapy continues to expand, and approved applications now include uterine fibroid ablation, cataract removal (phacoemulsification), surgical tissue cutting and hemostasis, transdermal drug delivery, and bone fracture healing, among others. Undesirable bioeffects can occur, including burns from thermal-based therapies and severe hemorrhage from mechanical-based therapies (eg, lithotripsy). In all of these therapeutic applications of ultrasound bioeffects, standardization, ultrasound dosimetry, benefits assurance, and side-effect risk minimization must be carefully considered to ensure an optimal benefit to risk ratio for the patient. Therapeutic ultrasound typically has well-defined benefits and risks and therefore presents a manageable safety problem to the clinician. However, safety information can be scattered, confusing, or subject to commercial conflicts of interest. Of paramount importance for managing this problem is the communication of practical safety information by authoritative groups, such as the American Institute of Ultrasound in Medicine, to the medical ultrasound community. In this overview, the Bioeffects Committee of the American Institute of Ultrasound in Medicine outlines the wide range of therapeutic ultrasound methods, which are in clinical use or under study, and provides general guidance for ensuring therapeutic ultrasound safety.
Collapse
Affiliation(s)
- Douglas L Miller
- Department of Radiology, University of Michigan, 3240A Medical Science Building I, 1301 Catherine St, Ann Arbor, MI 48109-5667, USA.
| | | | | | | | | | | |
Collapse
|
45
|
Kim J, Jang JH, Lee JH, Choi JK, Park WR, Bae IH, Bae J, Park JW. Enhanced Topical Delivery of Small Hydrophilic or Lipophilic Active Agents and Epidermal Growth Factor by Fractional Radiofrequency Microporation. Pharm Res 2012; 29:2017-29. [DOI: 10.1007/s11095-012-0729-1] [Citation(s) in RCA: 11] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/08/2012] [Accepted: 02/29/2012] [Indexed: 01/23/2023]
|
46
|
Ebrahimi S, Abbasnia K, Motealleh A, Kooroshfard N, Kamali F, Ghaffarinezhad F. Effect of lidocaine phonophoresis on sensory blockade: pulsed or continuous mode of therapeutic ultrasound? Physiotherapy 2012; 98:57-63. [DOI: 10.1016/j.physio.2011.01.009] [Citation(s) in RCA: 10] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/18/2010] [Accepted: 01/16/2011] [Indexed: 10/17/2022]
|
47
|
Ahmadi F, McLoughlin IV, Chauhan S, ter-Haar G. Bio-effects and safety of low-intensity, low-frequency ultrasonic exposure. PROGRESS IN BIOPHYSICS AND MOLECULAR BIOLOGY 2012; 108:119-38. [PMID: 22402278 DOI: 10.1016/j.pbiomolbio.2012.01.004] [Citation(s) in RCA: 113] [Impact Index Per Article: 9.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 10/25/2011] [Accepted: 01/30/2012] [Indexed: 11/25/2022]
Abstract
Low-frequency (LF) ultrasound (20-100 kHz) has a diverse set of industrial and medical applications. In fact, high power industrial applications of ultrasound mainly occupy this frequency range. This range is also used for various therapeutic medical applications including sonophoresis (ultrasonic transdermal drug delivery), dentistry, eye surgery, body contouring, the breaking of kidney stones and eliminating blood clots. While emerging LF applications such as ultrasonic drug delivery continue to be developed and undergo translation for human use, significant gaps exist in the coverage of safety standards for this frequency range. Accordingly, the need to understand the biological effects of LF ultrasound is becoming more important. This paper presents a broad overview of bio-effects and safety of LF ultrasound as an aid to minimize and control the risk of these effects. Its particular focus is at low intensities where bio-effects are initially observed. To generate a clear perspective of hazards in LF exposure, the mechanisms of bio-effects and the main differences in action at low and high frequencies are investigated and a survey of harmful effects of LF ultrasound at low intensities is presented. Mechanical and thermal indices are widely used in high frequency diagnostic applications as a means of indicating safety of ultrasonic exposure. The direct application of these indices at low frequencies needs careful investigation. In this work, using numerical simulations based on the mathematical and physical rationale behind the indices at high frequencies, it is observed that while thermal index (TI) can be used directly in the LF range, mechanical index (MI) seems to become less reliable at lower frequencies. Accordingly, an improved formulation for the MI is proposed for frequencies below 500 kHz.
Collapse
Affiliation(s)
- Farzaneh Ahmadi
- School of Computer Engineering, Nanyang Technological University, N4-02b-52, Nanyang Avenue, Singapore 639798, Singapore
| | | | | | | |
Collapse
|
48
|
Yeo LY, Chang HC, Chan PPY, Friend JR. Microfluidic devices for bioapplications. SMALL (WEINHEIM AN DER BERGSTRASSE, GERMANY) 2011; 7:12-48. [PMID: 21072867 DOI: 10.1002/smll.201000946] [Citation(s) in RCA: 294] [Impact Index Per Article: 22.6] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/18/2023]
Abstract
Harnessing the ability to precisely and reproducibly actuate fluids and manipulate bioparticles such as DNA, cells, and molecules at the microscale, microfluidics is a powerful tool that is currently revolutionizing chemical and biological analysis by replicating laboratory bench-top technology on a miniature chip-scale device, thus allowing assays to be carried out at a fraction of the time and cost while affording portability and field-use capability. Emerging from a decade of research and development in microfluidic technology are a wide range of promising laboratory and consumer biotechnological applications from microscale genetic and proteomic analysis kits, cell culture and manipulation platforms, biosensors, and pathogen detection systems to point-of-care diagnostic devices, high-throughput combinatorial drug screening platforms, schemes for targeted drug delivery and advanced therapeutics, and novel biomaterials synthesis for tissue engineering. The developments associated with these technological advances along with their respective applications to date are reviewed from a broad perspective and possible future directions that could arise from the current state of the art are discussed.
Collapse
Affiliation(s)
- Leslie Y Yeo
- Micro/Nanophysics Research Laboratory, Department of Mechanical & Aerospace Engineering, Monash University, Clayton, VIC 3800, Australia
| | | | | | | |
Collapse
|
49
|
Time-reversal Techniques in Ultrasound-assisted Convection-enhanced Drug Delivery to the Brain: Technology Development and In Vivo Evaluation. PROCEEDINGS OF MEETINGS ON ACOUSTICS. ACOUSTICAL SOCIETY OF AMERICA 2011; 11:20005-20031. [PMID: 21881622 DOI: 10.1121/1.3616358] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/20/2022]
Abstract
We describe a drug delivery method that combines Time-Reversal Acoustics (TRA) with Convection-Enhanced Delivery (CED) to improve the delivery of therapeutics to the interstitium of the brain. The Ultrasound-assisted CED approach (UCED) circumvents the blood-brain barrier by infusing compounds through a cannula that is inserted into the brain while simultaneously delivering ultrasound to improve the penetration of pharmaceuticals. CED without ultrasound-assistance has been used to treat a variety of neural disorders, including glioblastoma multiforme, a malignancy that presents a very poor prognosis for patients. We describe a novel system that is used to infuse fluids into the brain parenchyma while simultaneously exposing the tissue to safe levels of 1-MHz, low intensity, ultrasound energy. The system includes a combined infusion needle-hydrophone, a 10-channel ultralow-output impedance amplifier, a broad-band ultrasound resonator, and MatLab®-based TRA control and user-interface. TRA allows easy coupling of ultrasound therapy through the skull without complex phase-correction and array design. The smart targeting UCED system has been tested in vivo and results show it provides 1.5-mm spatial resolution for UCED and improves tracer distribution in the brain over CED alone.
Collapse
|
50
|
Maia Filho ALM, Villaverde AB, Munin E, Aimbire F, Albertini R. Comparative study of the topical application of Aloe vera gel, therapeutic ultrasound and phonophoresis on the tissue repair in collagenase-induced rat tendinitis. ULTRASOUND IN MEDICINE & BIOLOGY 2010; 36:1682-1690. [PMID: 20800944 DOI: 10.1016/j.ultrasmedbio.2010.06.012] [Citation(s) in RCA: 23] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 10/14/2009] [Revised: 05/06/2010] [Accepted: 06/15/2010] [Indexed: 05/29/2023]
Abstract
The aim of our study was to compare topical use of Aloe vera gel, pulsed mode ultrasound (US) and Aloe vera phonophoresis on rat paw with collagenase-induced tendinitis. Edema size, tensile tendon strength, tendon elasticity, number of inflammatory cells and tissue histology were studied at 7 and 14 days after tendinitis induction. Pulse mode US parameters were: 1 MHz frequency, 100 Hz repetition rate, 10% duty cycle, and 0.5 W/cm(2) intensity, applied for 2 min each session. A 0.5 mL of Aloe vera gel at 2% concentration was applied for 2 min per session, topically and by phonophoresis. Topical application of Aloe vera gel did not show any statistically significant improvement in the inflammatory process, whereas phonophoresis enhanced the gel action reducing edema and number of inflammatory cells, promoting the rearrangement of collagen fibers and promoting also the recovery of the tensile strength and elasticity of the inflamed tendon to recover their normal pre-injury status. Results seem to indicate that Aloe vera phonophoresis is a promising technique for tendinitis treatment, without the adverse effect provoked by systemic anti-inflammatory drugs.
Collapse
|