1
|
Bozza WP, Tolleson WH, Rivera Rosado LA, Zhang B. Ricin detection: Tracking active toxin. Biotechnol Adv 2015; 33:117-123. [DOI: 10.1016/j.biotechadv.2014.11.012] [Citation(s) in RCA: 66] [Impact Index Per Article: 7.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/02/2014] [Revised: 10/22/2014] [Accepted: 11/30/2014] [Indexed: 12/11/2022]
|
2
|
Balsam J, Rasooly R, Bruck HA, Rasooly A. Thousand-fold fluorescent signal amplification for mHealth diagnostics. Biosens Bioelectron 2014; 51:1-7. [PMID: 23928092 PMCID: PMC3795847 DOI: 10.1016/j.bios.2013.06.053] [Citation(s) in RCA: 21] [Impact Index Per Article: 2.1] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/19/2013] [Revised: 06/19/2013] [Accepted: 06/26/2013] [Indexed: 01/27/2023]
Abstract
The low sensitivity of Mobile Health (mHealth) optical detectors, such as those found on mobile phones, is a limiting factor for many mHealth clinical applications. To improve sensitivity, we have combined two approaches for optical signal amplification: (1) a computational approach based on an image stacking algorithm to decrease the image noise and enhance weak signals, and (2) an optical signal amplifier utilizing a capillary tube array. These approaches were used in a detection system which includes multi-wavelength LEDs capable of exciting many fluorophores in multiple wavelengths, a mobile phone or a webcam as a detector, and capillary tube array configured with 36 capillary tubes for signal enhancement. The capillary array enables a ~100× increase in signal sensitivity for fluorescein, reducing the limit of detection (LOD) for mobile phones and webcams from 1000 nM to 10nM. Computational image stacking enables another ~10× increase in signal sensitivity, further reducing the LOD for webcam from 10nM to 1 nM. To demonstrate the feasibility of the device for the detection of disease-related biomarkers, adenovirus DNA labeled with SYBR green or fluorescein was analyzed by both our capillary array and a commercial plate reader. The LOD for the capillary array was 5 ug/mL, and that of the plate reader was 1 ug/mL. Similar results were obtained using DNA stained with fluorescein. The combination of the two signal amplification approaches enables a ~1000× increase in LOD for the webcam platform. This brings it into the range of a conventional plate reader while using a smaller sample volume (10 ul) than the plate reader requires (100 ul). This suggests that such a device could be suitable for biosensing applications where up to 10 fold smaller sample sizes are needed. The simple optical configuration for mHealth described in this paper employing the combined capillary and image processing signal amplification is capable of measuring weak fluorescent signals without the need of dedicated laboratories. It has the potential to be used to increase sensitivity of other optically based mHealth technologies, and may increase mHealth's clinical utility, especially for telemedicine and for resource-poor settings and global health applications.
Collapse
Affiliation(s)
- Joshua Balsam
- Division of Biology, Office of Science and Engineering, FDA, Silver Spring, MD 20993, United States; University of Maryland, College Park, MD 20742, United States
| | | | | | | |
Collapse
|
3
|
Balsam J, Bruck HA, Rasooly A. Capillary Array Waveguide Amplified Fluorescence Detector for mHealth. SENSORS AND ACTUATORS. B, CHEMICAL 2013; 186:711-717. [PMID: 24039345 PMCID: PMC3769705 DOI: 10.1016/j.snb.2013.06.030] [Citation(s) in RCA: 13] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/02/2023]
Abstract
Mobile Health (mHealth) analytical technologies are potentially useful for carrying out modern medical diagnostics in resource-poor settings. Effective mHealth devices for underserved populations need to be simple, low cost, and portable. Although cell phone cameras have been used for biodetection, their sensitivity is a limiting factor because currently it is too low to be effective for many mHealth applications, which depend on detection of weak fluorescent signals. To improve the sensitivity of portable phones, a capillary tube array was developed to amplify fluorescence signals using their waveguide properties. An array configured with 36 capillary tubes was demonstrated to have a ~100X increase in sensitivity, lowering the limit of detection (LOD) of mobile phones from 1000 nM to 10 nM for fluorescein. To confirm that the amplification was due to waveguide behavior, we coated the external surfaces of the capillaries with silver. The silver coating interfered with the waveguide behavior and diminished the fluorescence signal, thereby proving that the waveguide behavior was the main mechanism for enhancing optical sensitivity. The optical configuration described here is novel in several ways. First, the use of capillaries waveguide properties to improve detection of weak florescence signal is new. Second we describe here a three dimensional illumination system, while conventional angular laser waveguide illumination is spot (or line), which is functionally one-dimensional illumination, can illuminate only a single capillary or a single column (when a line generator is used) of capillaries and thus inherently limits the multiplexing capability of detection. The planar illumination demonstrated in this work enables illumination of a two dimensional capillary array (e.g. x columns and y rows of capillaries). In addition, the waveguide light propagation via the capillary wall provides a third dimension for illumination along the axis of the capillaries. Such an array can potentially be used for sensitive analysis of multiple fluorescent detection assays simultaneously. The simple phone based capillary array approach presented in this paper is capable of amplifying weak fluorescent signals thereby improving the sensitivity of optical detectors based on mobile phones. This may allow sensitive biological assays to be measured with low sensitivity detectors and may make mHealth practical for many diagnostics applications, especially in resource-poor and global health settings.
Collapse
Affiliation(s)
- Joshua Balsam
- Division of Biology, Office of Science and Engineering, FDA, Silver Spring, MD 20993 ; University of Maryland, College Park, MD 20742
| | | | | |
Collapse
|
4
|
Yang X, Kirsch J, Simonian A. Campylobacter spp. detection in the 21st century: a review of the recent achievements in biosensor development. J Microbiol Methods 2013; 95:48-56. [PMID: 23830967 DOI: 10.1016/j.mimet.2013.06.023] [Citation(s) in RCA: 18] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/06/2012] [Revised: 04/18/2013] [Accepted: 06/10/2013] [Indexed: 10/26/2022]
Abstract
Campylobacter spp. are an important cause of acute bacterial diseases in humans worldwide. Many bacterial species in the Campylobacter genus are considered harmful and may cause several infectious diseases. Currently, there are no commercial biosensors available to detect Campylobacter spp. in food matrices, and little to no testing has been done in research laboratories with actual food matrices. Biosensors potentially provide a powerful means to detect Campylobacter spp. with the advantages of high sensitivity (low limits of detection with a high signal to noise ratio), high specificity (able to selectively detect the target among several similar targets), real time sensing, and in-site monitoring. This review summarizes the latest research in biosensing technologies for detection of Campylobacter spp. based on a variety of transducers and recognition elements. Finally, a comparison is made among all recently reported biosensors for the detection of Campylobacter spp.
Collapse
Affiliation(s)
- Xiaoyun Yang
- Department of Materials Engineering, Auburn University, AL 36849, USA
| | | | | |
Collapse
|
5
|
He F, Xiang M, Mi X. A New Bacteriophage-Modified Piezoelectric Sensor for Rapid and Specific detection of Mycobacterium. ANAL LETT 2012. [DOI: 10.1080/00032719.2012.673106] [Citation(s) in RCA: 7] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/28/2022]
|
6
|
Suresh S, Gupta M, Kumar GA, Rao VK, Kumar O, Ghosal P. Synergic effect of multi-walled carbon nanotubes and gold nanoparticles towards immunosensing of ricin with carbon nanotube–gold nanoparticles–chitosan modified screen printed electrode. Analyst 2012; 137:4086-92. [DOI: 10.1039/c2an35279f] [Citation(s) in RCA: 22] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/21/2022]
|
7
|
Detection of ricin using a carbon nanofiber based biosensor. Biosens Bioelectron 2011; 28:428-33. [DOI: 10.1016/j.bios.2011.07.061] [Citation(s) in RCA: 27] [Impact Index Per Article: 2.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/09/2011] [Revised: 07/11/2011] [Accepted: 07/25/2011] [Indexed: 11/20/2022]
|
8
|
Zhang Y, Wang H, Li J, Nie J, Zhang Y, Shen G, Yu R. Nitrocellulose strip array assembled on superhydrophobic surface: An aqueous solution diffusion-localized platform for multianalyte immunogold staining assays. Biosens Bioelectron 2011; 26:3272-7. [DOI: 10.1016/j.bios.2010.12.040] [Citation(s) in RCA: 10] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/07/2010] [Revised: 11/18/2010] [Accepted: 12/27/2010] [Indexed: 11/26/2022]
|
9
|
A digital microfluidic approach to heterogeneous immunoassays. Anal Bioanal Chem 2010; 399:337-45. [DOI: 10.1007/s00216-010-4368-2] [Citation(s) in RCA: 46] [Impact Index Per Article: 3.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/02/2010] [Revised: 10/14/2010] [Accepted: 10/19/2010] [Indexed: 10/18/2022]
|
10
|
Zhong Z, Fritzsche M, Pieper SB, Wood TK, Lear KL, Dandy DS, Reardon KF. Fiber optic monooxygenase biosensor for toluene concentration measurement in aqueous samples. Biosens Bioelectron 2010; 26:2407-12. [PMID: 21081273 DOI: 10.1016/j.bios.2010.10.021] [Citation(s) in RCA: 11] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/16/2010] [Revised: 10/07/2010] [Accepted: 10/11/2010] [Indexed: 11/19/2022]
Abstract
Measurements of pollutants such as toluene are critical for the characterization of contaminated sites and for the monitoring of remediation processes and wastewater treatment effluents. Fiber optic enzymatic biosensors have the potential to provide cost-effective, real time, continuous, in situ measurements. In this study, a fiber optic enzymatic biosensor was constructed and characterized for the measurement of toluene concentrations in aqueous solutions. The biological recognition element was toluene ortho-monooxygenase (TOM), expressed by Escherichia coli TG1 carrying pBS(Kan)TOM, while an optical fiber coated with an oxygen-sensitive ruthenium-based phosphorescent dye served as the transducer. Toluene was detected based on the enzymatic reaction catalyzed by TOM, which resulted in the consumption of oxygen and changes in the phosphorescence intensity. The biosensor was found to have a limit of detection of 3 μM, a linear signal range up to 100 μM, and a response time of 1 h. The performance was reproducible with different biosensors (RSD=7.4%, n=8). The biosensor activity declined with each measurement and with storage time, particularly at elevated temperatures. This activity loss could be partially reversed by exposure to formate, suggesting that NADH consumption was the primary factor limiting lifetime. This is the first report of an enzymatic toluene sensor and of an oxygenase-based biosensor. Since many oxygenases have been reported, the design concept of this oxygenase-based biosensor has the potential to broaden biosensor applications in environmental monitoring.
Collapse
Affiliation(s)
- Zhong Zhong
- Department of Chemical and Biological Engineering, Colorado State University, Fort Collins, CO 80523, USA
| | | | | | | | | | | | | |
Collapse
|
11
|
Padmanabhan S, Shinoj VK, Murukeshan VM, Padmanabhan P. Highly sensitive optical detection of specific protein in breast cancer cells using microstructured fiber in extremely low sample volume. JOURNAL OF BIOMEDICAL OPTICS 2010; 15:017005. [PMID: 20210479 DOI: 10.1117/1.3302810] [Citation(s) in RCA: 13] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/28/2023]
Abstract
A simple optical method using hollow-core photonic crystal fiber for protein detection has been described. In this study, estrogen receptor (ER) from a MCF-7 breast carcinoma cell lysates immobilized inside a hollow-core photonic crystal fiber was detected using anti-ER primary antibody with either Alexa Fluor 488 (green fluorescent dye) or 555 (red Fluorescent dye) labeled Goat anti-rabbit IgG as the secondary antibody. The fluorescence fingerprints of the ERalpha protein were observed under fluorescence microscope, and its optical characteristics were analyzed. The ERalpha protein detection by this proposed method is based on immuno binding from sample volume as low as 50 nL. This method is expected to offer great potential as a biosensor for medical diagnostics and therapeutics applications.
Collapse
Affiliation(s)
- Saraswathi Padmanabhan
- Nanyang Technological University, School of Mechanical and Aerospace Engineering, Singapore
| | | | | | | |
Collapse
|
12
|
Shabani A, Zourob M, Allain B, Marquette CA, Lawrence MF, Mandeville R. Bacteriophage-modified microarrays for the direct impedimetric detection of bacteria. Anal Chem 2009; 80:9475-82. [PMID: 19072262 DOI: 10.1021/ac801607w] [Citation(s) in RCA: 94] [Impact Index Per Article: 6.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/29/2022]
Abstract
A novel method is presented for the specific and direct detection of bacteria using bacteriophages as recognition receptors immobilized covalently onto functionalized screen-printed carbon electrode (SPE) microarrays. The SPE networks were functionalized through electrochemical oxidation in acidic media of 1-ethyl-3-(3-dimethylaminopropyl)carbodiimide (EDC) by applying a potential of +2.2 V to the working electrode. Immobilization of T4 bacteriophage onto the SPEs was achieved via EDC by formation of amide bonds between the protein coating of the phage and the electrochemically generated carboxylic groups at the carbon surface. The surface functionalization with EDC, and the binding of phages, was verified by time-of-flight secondary ion mass spectrometry. The immobilized T4 phages were then used to specifically detect E. coli bacteria. The presence of surface-bound bacteria was verified by scanning electron and fluorescence microscopies. Impedance measurements (Nyquist plots) show shifts of the order of 10(4) Omega due to the binding of E. coli bacteria to the T4 phages. No significant change in impedance was observed for control experiments using immobilized T4 phage in the presence of Salmonella. Impedance variations as a function of incubation time show a maximum shift after 20 min, indicating onset of lysis, as also confirmed by fluorescence microscopy. Concentration-response curves yield a detection limit of 10(4) cfu/mL for 50-microL samples.
Collapse
|
13
|
Kim JS, Anderson GP, Erickson JS, Golden JP, Nasir M, Ligler FS. Multiplexed detection of bacteria and toxins using a microflow cytometer. Anal Chem 2009; 81:5426-32. [PMID: 19496600 DOI: 10.1021/ac9005827] [Citation(s) in RCA: 93] [Impact Index Per Article: 6.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/28/2022]
Abstract
A microfabricated flow cytometer was used to demonstrate multiplexed detection of bacteria and toxins using fluorescent coded microspheres. Antibody-coated microspheres bound biothreat targets in a sandwich immunoassay format. The microfluidic cytometer focused the microspheres in three dimensions within the laser interrogation region using passive groove structures to surround the sample stream with sheath fluid. Optical analysis at four different wavelengths identified the coded microspheres and quantified target bound by the presence of phycoerythrin tracer. The multiplexed assays in the microflow cytometer had performance approaching that of a commercial benchtop flow cytometer. The respective limits of detection for bacteria (Escherichia coli, Listeria, and Salmonella) were found to be 10(3), 10(5), and 10(4) cfu/mL for the microflow cytometer and 10(3), 10(6), and 10(5) cfu/mL for the commercial system. Limits of detection for the toxins (cholera toxin, staphylococcal enterotoxin B, and ricin) were 1.6, 0.064, and 1.6 ng/mL for the microflow cytometer and 1.6, 0.064, and 8.0 ng/mL for the commercial system.
Collapse
Affiliation(s)
- Jason S Kim
- Center for Bio/Molecular Science and Engineering, Naval Research Laboratory, 4555 Overlook Avenue SW, Washington, DC 20375, USA
| | | | | | | | | | | |
Collapse
|
14
|
Abstract
Antibody-based microarrays are a new powerful proteomic technology that can be used to generate rapid and detailed expression profiles of defined sets of protein analytes in complex samples as well as high-resolution portraits of entire proteomes. Miniaturized micro- and nanoarrays can be printed with numerous antibodies carrying the desired specificities. Multiplexed and ultra-sensitive assays, specifically targeting several analytes in a single experiment, can be performed, while consuming only minute amounts of the sample. The array images generated can then be converted into protein expression profiles, or maps, revealing the detailed composition of the sample. This promising proteomic research tool will thus provide unique opportunities for e.g. disease proteomics, biomarker discovery, disease diagnostics, and patient stratification. This review describes the antibody-based microarray technology and applications thereof.
Collapse
|
15
|
Taitt CR, North SH, Kulagina NV. Antimicrobial peptide arrays for detection of inactivated biothreat agents. Methods Mol Biol 2009; 570:233-255. [PMID: 19649597 DOI: 10.1007/978-1-60327-394-7_11] [Citation(s) in RCA: 10] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 05/28/2023]
Abstract
Arrays of immobilized antimicrobial peptides are used to detect bacterial, viral, and rickettsial pathogens, including inactivated biothreat agents. These arrays differ from the many combinatorial peptide arrays described in the literature in that the peptides used here have naturally evolved to interact with and disrupt microbial membranes with high affinity but broad specificity. The interaction of these naturally occurring peptides with membranes of pathogens has been harnessed for the purpose of detection, with immobilized antimicrobial peptides acting as "capture" molecules in detection assays. Methods are presented for immobilizing the antimicrobial peptides in planar arrays, performing direct and sandwich assays, and detecting bound targets.
Collapse
|
16
|
Reusable optical bioassay platform with permeability-controlled hydrogel pads for selective saccharide detection. Anal Chim Acta 2008; 607:204-10. [DOI: 10.1016/j.aca.2007.11.046] [Citation(s) in RCA: 16] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/14/2007] [Revised: 11/23/2007] [Accepted: 11/27/2007] [Indexed: 11/23/2022]
|
17
|
Abstract
Toxic fungal metabolites - mycotoxins - cause poisonings after consumption of contaminated food commodities. The most probable intoxications are connected with eating poorly stored food or inhaling of moldy dust. One of the effective ways to protect people against mycotoxins is timely detection. Several methods such as affinity chromatography and enzyme-linked immunosorbent assay are commercially available for this purpose. Nevertheless, fast, sensitive, simple, portable, and low-cost devices are difficult to find. Application of biosensors appears to be a possible method to meet this need for mycotoxins assay.
Collapse
Affiliation(s)
- Miroslav Pohanka
- Centre of Biological Defense, Techonín, Central Military Institute of Health, Techonin, Czech Republic
| | | | | |
Collapse
|
18
|
Rodriguez-Mozaz S, Lopez de Alda MJ, Barceló D. Advantages and limitations of on-line solid phase extraction coupled to liquid chromatography–mass spectrometry technologies versus biosensors for monitoring of emerging contaminants in water. J Chromatogr A 2007; 1152:97-115. [PMID: 17275010 DOI: 10.1016/j.chroma.2007.01.046] [Citation(s) in RCA: 181] [Impact Index Per Article: 10.6] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/09/2006] [Revised: 12/22/2006] [Accepted: 01/12/2007] [Indexed: 11/29/2022]
Abstract
On-line solid phase extraction (SPE) coupled to liquid chromatography-mass spectrometry (LC-MS) and biosensors are advanced technologies that have found increasing application in the analysis of environmental contaminants although their application to the determination of emerging contaminants (previously unknown or unrecognized pollutants) has been still limited. This review covers the most recent advances occurred in the areas of on-line SPE-LC-MS and biosensors, discusses and compares the main strengths and limitations of the two approaches, and examines their most relevant applications to the analysis of emerging contaminants in environmental waters. So far, the on-line configuration most frequently used has been SPE coupled to liquid chromatography-(tandem) mass spectrometry. Sorbents used for on-line SPE have included both traditional (alkyl-bonded silicas and polymers) and novel (restricted access materials (RAMs), molecularly imprinted synthetic polymers (MIPs), and immobilized receptors or antibodies (immunosorbents) materials. The biosensor technologies most frequently applied have been based on the use of antibodies and, to a lesser extent, enzymes, bacteria, receptors and DNA as recognition elements, and the use of optical and electrochemical transducing elements. Emerging contaminants investigated by means of these two techniques have included pharmaceuticals, endocrine disrupting compounds such as estrogens, alkylphenols and bisphenol A, pesticides transformation products, disinfection by-products, and bacterial toxins and mycotoxins, among others. Both techniques offer advantageous, and frequently comparable, features such as high sensitivity and selectivity, minimum sample manipulation, and automation. Biosensors are, in addition, relatively cheap and fast, which make them ideally suited for routine testing and screening of samples; however, in most cases, they can not compete yet with on-line SPE procedures in terms of accuracy, reproducibility, reliability (confirmation) of results, and capacity for multi-analyte determination.
Collapse
Affiliation(s)
- Sara Rodriguez-Mozaz
- Department of Environmental Chemistry, IIQAB-CSIC, C/Jordi Girona 18-26, 08034 Barcelona, Spain
| | | | | |
Collapse
|
19
|
Mei Q, Fredrickson CK, Lian W, Jin S, Fan ZH. Ricin detection by biological signal amplification in a well-in-a-well device. Anal Chem 2007; 78:7659-64. [PMID: 17105156 DOI: 10.1021/ac0610006] [Citation(s) in RCA: 25] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/28/2022]
Abstract
This paper presents a ricin detection method based on ricin's inhibitory effects on protein synthesis. Biological synthesis (expression) of a protein includes the steps of gene transcription (DNA --> RNA) and protein translation (RNA --> proteins); these reactions can be coupled into a one-step operation and carried out in a cell-free medium. Ricin is known to inhibit protein synthesis by interacting with 28S ribosome RNA; the inhibitory effect is exploited as the sensing mechanism in this work. For each copy of DNA, thousands of copies of proteins can be produced. As a result, the inhibitory effects of ricin are amplified, leading to a significantly enhanced detection signal (the difference between the positive control and samples). An array of protein expression units is developed to accommodate positive/negative controls and multiple samples. The array device contains a solution without any reagent captured on a solid surface, offering flexibility without comprising the activities of biomolecules. The miniaturized well-in-a-well design possesses a mechanism to supply nutrients continuously and remove byproducts, leading to higher protein expression yields and thus larger detection signals (lower detection limit) when ricin is present. We demonstrate the production of green fluorescent protein and luciferase in the device. A calibration curve has been obtained between the luciferase expression yield and the ricin concentration, showing a detection limit of 0.01 nM (0.3 ng/mL) ricin. The nested-well device is also used for measuring the toxicity level of ricin after physical or chemical treatment.
Collapse
Affiliation(s)
- Qian Mei
- Department of Mechanical and Aerospace Engineering, University of Florida, P.O. Box 116250, Gainesville, Florida 32611, USA
| | | | | | | | | |
Collapse
|
20
|
Mauriz E, Calle A, Manclús JJ, Montoya A, Lechuga LM. Multi-analyte SPR immunoassays for environmental biosensing of pesticides. Anal Bioanal Chem 2006; 387:1449-58. [PMID: 17063364 DOI: 10.1007/s00216-006-0800-z] [Citation(s) in RCA: 67] [Impact Index Per Article: 3.7] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/02/2006] [Revised: 08/18/2006] [Accepted: 08/23/2006] [Indexed: 10/24/2022]
Abstract
Multi-analyte detection of environmentally relevant pesticides is performed by using a two-channelled surface plasmon resonance (SPR) biosensor. The special design of the SPR instrument allows the determination of several analytes (DDT, chlorpyrifos and carbaryl) via different immobilization formats. First, simultaneous pesticide monitoring is possible by flowing chlorpyrifos, carbaryl or DDT samples separately over each channel of the SPR system, wherein their corresponding recognition element was previously immobilized. The second approach is based on the multiple and combined immobilization of several analyte recognition elements on the sensing surface of one individual flow cell. In this format, the analysis time for all three pesticides varied from 40 to 60 min depending on the number of regeneration cycles. In most cases, similar detection limits were attained for the target analyte irrespective of the assay format, with sensitivity values at the nanogram per litre level (18-50 ng L(-1)). The assay reproducibility was proved through the repeated use of the same sensor surface for over more than 200 assay cycles, whereas the absence of biosensor response to non-related analytes showed the specificity and reliability of the analysis. The SPR instrument, including optics, electronics and microfluidics, is already commercialised by the company SENSIA, SL.
Collapse
Affiliation(s)
- E Mauriz
- Biosensors Group, Microelectronics National Centre, CSIC, Isaac Newton 8, 28760 Tres Cantos, Madrid, Spain.
| | | | | | | | | |
Collapse
|
21
|
Ler SG, Lee FK, Gopalakrishnakone P. Trends in detection of warfare agents. Detection methods for ricin, staphylococcal enterotoxin B and T-2 toxin. J Chromatogr A 2006; 1133:1-12. [PMID: 16996531 DOI: 10.1016/j.chroma.2006.08.078] [Citation(s) in RCA: 95] [Impact Index Per Article: 5.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/16/2006] [Revised: 08/21/2006] [Accepted: 08/28/2006] [Indexed: 10/24/2022]
Abstract
An overview of the different detection methods available for ricin, staphylococcal enterotoxin B (SEB) and T-2 toxin is presented here. These toxins are potential biological warfare agents (BWA). The aim of this review is not to cover all the papers that had been published but rather to give an overall picture of the trend in the detection methodologies for potential biological warfare agents as we do see the emerging threats from these three toxins. The advantages and disadvantages of each methodology as well as the detection limit will be reviewed. It seems that mass spectrometry has created a niche for analysis of proteinaceous toxins, ricin and SEB as well as molecular toxin, T-2 toxin given its high sensitivity, high selectivity, high specificity and capability to identify and quantify unknown agents simultaneously in a short time frame. But its main drawbacks are its sophisticated instrumentation and its high cost. Improvised immunoassay may be an alternative.
Collapse
Affiliation(s)
- Siok Ghee Ler
- Venom and Toxin Research Programme, Yong Loo Lin School of Medicine, National University of Singapore, 4 Medical Drive, Singapore 117597, Singapore
| | | | | |
Collapse
|
22
|
Rodriguez-Mozaz S, Lopez de Alda MJ, Barceló D. Biosensors as useful tools for environmental analysis and monitoring. Anal Bioanal Chem 2006; 386:1025-41. [PMID: 16807703 DOI: 10.1007/s00216-006-0574-3] [Citation(s) in RCA: 195] [Impact Index Per Article: 10.8] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/07/2006] [Revised: 04/23/2006] [Accepted: 05/22/2006] [Indexed: 10/24/2022]
Abstract
Recent advances in the development and application of biosensors for environmental analysis and monitoring are reviewed in this article. Several examples of biosensors developed for relevant environmental pollutants and parameters are briefly overviewed. Special attention is paid to the application of biosensors to real environmental samples, taking into consideration aspects such as sample pretreatment, matrix effects and validation of biosensor measurements. Current trends in biosensor development are also considered and commented on in this work. In this context, nanotechnology, miniaturisation, multi-sensor array development and, especially, biotechnology arise as fast-growing areas that will have a marked influence on the development of new biosensing strategies in the near future.
Collapse
Affiliation(s)
- Sara Rodriguez-Mozaz
- Department of Environmental Chemistry, IIQAB-CSIC, C/ Jordi Girona 18-26, 08034, Barcelona, Spain.
| | | | | |
Collapse
|
23
|
Ince R, Narayanaswamy R. Analysis of the performance of interferometry, surface plasmon resonance and luminescence as biosensors and chemosensors. Anal Chim Acta 2006. [DOI: 10.1016/j.aca.2006.03.058] [Citation(s) in RCA: 57] [Impact Index Per Article: 3.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/24/2022]
|
24
|
Chung JW, Bernhardt R, Pyun JC. Sequential analysis of multiple analytes using a surface plasmon resonance (SPR) biosensor. J Immunol Methods 2006; 311:178-88. [PMID: 16580012 DOI: 10.1016/j.jim.2006.02.003] [Citation(s) in RCA: 24] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/06/2005] [Revised: 01/06/2006] [Accepted: 02/08/2006] [Indexed: 11/23/2022]
Abstract
A sequential analysis method for the analysis of two analytes was developed using a surface plasmon resonance (SPR) biosensor. A sample with both analytes was introduced into the single sensing region and then each analyte was analyzed sequentially. Two detection models were devised for the samples with the following composition: (1) one target analyte resulting in a sensor response without any label and the other analyte with only additional label, (2) both target analytes requiring additional labels for detection. A standard curve for each model was prepared and applied for sequential analysis of anti-bovine serum albumin (anti-BSA) antibodies and horseradish peroxidase (HRP). The errors of the sequential analysis of Models 1 and 2 were found to be less than 6%, and this method was therefore acceptable for application. No cross-reaction arising from non-specific binding among the participating antigens and antibodies was shown to occur in Models 1 and 2. For optimization of the analyte binding capacity of immunoaffinity (IA), the concentration ratio of the molecular recognition element at the immobilization step was adjusted. Subsequently, from the measurement of the maximum sensor response (R(max)), optimization of the analyte binding capacity could be made. Using Model 2, the feasibility of sequential analysis was demonstrated by detecting levels of human chorionic gonadotropin (hCG) and human albumin (hA) in healthy human urine, since both proteins are known to be related to abortion and preterm delivery during early pregnancy.
Collapse
Affiliation(s)
- J W Chung
- Korea Institute for Science and Technology Europe (KIST Europe fGmbH), Stuhlsatzenhausweg 97, 66123 Saarbruecken, Germany
| | | | | |
Collapse
|
25
|
Bally M, Halter M, Vörös J, Grandin HM. Optical microarray biosensing techniques. SURF INTERFACE ANAL 2006. [DOI: 10.1002/sia.2375] [Citation(s) in RCA: 140] [Impact Index Per Article: 7.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/09/2022]
|
26
|
Golden J, Shriver-Lake L, Sapsford K, Ligler F. A “do-it-yourself” array biosensor. Methods 2005; 37:65-72. [PMID: 16202623 DOI: 10.1016/j.ymeth.2005.05.010] [Citation(s) in RCA: 27] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/01/2005] [Accepted: 05/01/2005] [Indexed: 11/18/2022] Open
Abstract
We have developed an array biosensor for the simultaneous detection of multiple targets in multiple samples within 15-30 min. The biosensor is based on a planar waveguide, a modified microscope slide, with a pattern of small (mm2) sensing regions. The waveguide is illuminated by launching the emission of a 635 nm diode laser into the proximal end of the slide via a line generator. The evanescent field excites fluorophores bound in the sensing region and the emitted fluorescence is measured using a Peltier-cooled CCD camera. Assays can be performed on the waveguide in multichannel flow chambers and then interrogated using the detection system described here. This biosensor can detect many different targets, including proteins, toxins, cells, virus, and explosives with detection limits rivaling those of the ELISA detection system.
Collapse
Affiliation(s)
- Joel Golden
- Naval Research Laboratory, Code 6900, SW, Washington, DC 20375-5348, USA.
| | | | | | | |
Collapse
|
27
|
Chase CJ, Ulrich MP, Wasieloski LP, Kondig JP, Garrison J, Lindler LE, Kulesh DA. Real-time PCR assays targeting a unique chromosomal sequence of Yersinia pestis. Clin Chem 2005; 51:1778-85. [PMID: 16099940 DOI: 10.1373/clinchem.2005.051839] [Citation(s) in RCA: 30] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/06/2022]
Abstract
BACKGROUND Yersinia pestis, the causative agent of the zoonotic infection plague, is a major concern as a potential bioweapon. Current real-time PCR assays used for Y. pestis detection are based on plasmid targets, some of which may generate false-positive results. METHODS Using the yp48 gene of Y. pestis, we designed and tested 2 real-time TaqMan minor groove binder (MGB) assays that allowed us to use chromosomal genes as both confirmatory and differential targets for Y. pestis. We also designed several additional assays using both Simple-Probe and MGB Eclipse probe technologies for the selective differentiation of Yersinia pseudotuberculosis from Y. pestis. These assays were designed around a 25-bp insertion site recently identified within the yp48 gene of Y. pseudotuberculosis. RESULTS The Y. pestis-specific assay distinguished this bacterium from other Yersinia species but had unacceptable low-level detection of Y. pseudotuberculosis, a closely related species. Simple-Probe and MGB Eclipse probes specific for the 25-bp insertion detected only Y. pseudotuberculosis DNA. Probes that spanned the deletion site detected both Y. pestis and Y. pseudotuberculosis DNA, and the 2 species were clearly differentiated by a post-PCR melting temperature (Tm) analysis. The Simple-Probe assay produced an almost 7 degrees C Tm difference and the MGB Eclipse probe a slightly more than 4 degrees C difference. CONCLUSIONS Our method clearly discriminates Y. pestis DNA from all other Yersinia species tested and from the closely related Y. pseudotuberculosis. These chromosomal assays are important both to verify the presence of Y. pestis based on a chromosomal target and to easily distinguish it from Y. pseudotuberculosis.
Collapse
Affiliation(s)
- Catherine J Chase
- Diagnostic Systems Division, The United States Army Medical Research Institute of Infectious Diseases, Fort Detrick, Frederick, MD 21702-5011, USA
| | | | | | | | | | | | | |
Collapse
|
28
|
Abstract
Botulism is a deadly disease caused by ingestion of the preformed neurotoxin produced from the anaerobic spore-forming bacteria Clostridium botulinum. Botulinum neurotoxins are the most poisonous toxins known and have been a concern in the food industry for a long time. Therefore, rapid identification of botulinum neurotoxin using molecular and biochemical techniques is an essential component in the establishment of coordinated laboratory response systems and is the focus of current research and development. Because of the extreme toxicity of botulinum neurotoxin, some confirmatory testing with the mouse bioassay is still necessary, but rapid methods capable of screening large numbers of samples are also needed. This review is focused on the development of several detection methods for botulinum neurotoxins in foods.
Collapse
Affiliation(s)
- Shashi K Sharma
- Center for Food Safety and Applied Nutrition, U.S. Food and Drug Administration, College Park, Maryland 20740-3835, USA.
| | | |
Collapse
|
29
|
Taitt CR, Anderson GP, Ligler FS. Evanescent wave fluorescence biosensors. Biosens Bioelectron 2005; 20:2470-87. [PMID: 15854820 DOI: 10.1016/j.bios.2004.10.026] [Citation(s) in RCA: 131] [Impact Index Per Article: 6.9] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/04/2004] [Revised: 10/24/2004] [Accepted: 10/28/2004] [Indexed: 10/26/2022]
Abstract
Since discovery and first use in the mid-1970s, evanescent wave fluorescence biosensors have developed into a diverse range of instruments, each designed to meet a particular detection need. In this review, we provide a brief synopsis of what evanescent wave fluorescence biosensors are, how they work, and how they are used. In addition, we have summarized the important patents that have impacted the evolution from laboratory curiosities to fully automated commercial products. Finally, we address the critical issues that evanescent wave fluorescence biosensors will face in the coming years.
Collapse
Affiliation(s)
- Chris Rowe Taitt
- Center for Bio/Molecular Science and Engineering, US Naval Research Laboratory, Washington, DC 20375-5348, USA
| | | | | |
Collapse
|
30
|
Stine R, Pishko MV, Schengrund CL. Comparison of Glycosphingolipids and Antibodies as Receptor Molecules for Ricin Detection. Anal Chem 2005; 77:2882-8. [PMID: 15859606 DOI: 10.1021/ac048126s] [Citation(s) in RCA: 28] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/30/2022]
Abstract
Glycosphingolipids (GSLs) have been shown to undergo strong interactions with a number of protein toxins, including potential bioterrorism agents such as ricin and botulinum neurotoxin. Characterization of this interaction in recent years has led to a number of studies where GSLs were used as the recognition molecules for biosensing applications. Here, we offer a comparison of quartz crystal microbalance (QCM) sensors for the detection of ricin using antibodies and the GSLs GM1 and asialoGM1, which have been shown to undergo strong interactions with ricin. The presence, orientation, and activity of the GSL and antibody films were confirmed using ellipsometry, Fourier transform infrared spectroscopy (FT-IR), and QCM. It was found that the GSLs offered more sensitive detection limits when directly compared with antibodies. Both GSLs had lower detection limits at 5 microg/mL, approximately 5 times lower than were found for antibodies (25 microg/mL), and their linear detection range extended to the highest concentrations tested (100 microg/mL), almost an order of magnitude beyond the saturation point for the antibody sensors. Potential sites for nonspecific adsorption were blocked using serum albumin without sacrificing toxin specificity.
Collapse
Affiliation(s)
- Rory Stine
- Department of Chemical Engineering, Pennsylvania State University, University Park, Pennsylvania 16802, USA
| | | | | |
Collapse
|
31
|
Zourob M, Mohr S, Treves Brown BJ, Fielden PR, McDonnell MB, Goddard NJ. An Integrated Metal Clad Leaky Waveguide Sensor for Detection of Bacteria. Anal Chem 2004; 77:232-42. [PMID: 15623301 DOI: 10.1021/ac049627g] [Citation(s) in RCA: 61] [Impact Index Per Article: 3.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/28/2022]
Abstract
An integrated optical metal clad leaky waveguide (MCLW) sensor device has been developed for the detection of bacteria. This is more sensitive than waveguide sensors currently in use. The MCLW device has been fabricated to extend the evanescent field to provide significant light intensity over the entire volume of the bacteria bound on the chip surface within this field. This in turn increases the interaction of the light with the entire volume of the bacteria. MCLW devices have been used for detecting refractive index changes, scattering, and fluorescence from bacterial spores captured on an immobilized antibody. The detection limit of Bacillus subtilis var. niger bacterial spores using refractive index detection was 8 x10(4) spores/mL. The scattering intensity of the BG spores was found to be three times greater than the scattering intensity generated using surface plasmon resonance. The extended light propagation along the direction of flow for a few millimeters provides an effective interrogation approach to increase the area of detection to detect low concentrations down to 1 x 10(4) spores/mL. The sensor was then optimized by studying the key factors affecting sensor performance including changing the pH of the medium, type of antibody immobilization matrix, sensor surface regeneration approaches, and longevity of the sensor.
Collapse
Affiliation(s)
- Mohammed Zourob
- Department of Instrumentation and Analytical Science, The University of Manchester, P.O. Box 88, Manchester M60 1QD, U.K
| | | | | | | | | | | |
Collapse
|
32
|
Tencza SB, Sipe MA. Detection and classi?cation of threat agents via high-content assays of mammalian cells. J Appl Toxicol 2004; 24:371-7. [PMID: 15478183 DOI: 10.1002/jat.1025] [Citation(s) in RCA: 14] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/08/2022]
Abstract
One property common to all chemical or biological threat agents is that they damage mammalian cells. A threat detection and classification method based on the effects of compounds on cells has been developed. This method employs high-content screening (HCS), a concept in drug discovery that enables those who practice cell-based assays to generate deeper biological information about the compounds they are testing. A commercial image-based cell screening platform comprising fluorescent reagents, automated image acquisition hardware, image analysis algorithms, data management and informatics was used to develop assays and detection/classification methods for threat agents. These assays measure a cell's response to a compound, which may include activation or inhibition of signal transduction pathways, morphological changes or cytotoxic effects. Data on cell responses to a library of compounds was collected and used as a training set. At the EILATox-Oregon Workshop, cellular responses following exposure to unknown samples were measured by conducting assays of p38 MAP kinase, NF-kappaB, extracellular-signal related kinase (ERK) MAP kinase, cyclic AMP-response element binding protein (CREB), cell permeability, lysosomal mass and nuclear morphology. Although the assays appeared to perform well, only four of the nine toxic samples were detected. However the system was specific, because no false positives were detected. Opportunities for improvement to the system were identified during the course of this enlightening workshop. Some of these improvements were applied in subsequent tests in the Cellomics laboratories, resulting in a higher level of detection. Thus, an HCS approach was shown to have potential in detecting threat agents, but additional work is necessary to make this a comprehensive detection and classification system.
Collapse
Affiliation(s)
- Sarah B Tencza
- Cellomics Inc., 100 Technology Drive, Pittsburgh, PA 15219, USA
| | | |
Collapse
|
33
|
Sapsford KE, Shubin YS, Delehanty JB, Golden JP, Taitt CR, Shriver-Lake LC, Ligler FS. Fluorescence-based array biosensors for detection of biohazards. J Appl Microbiol 2004; 96:47-58. [PMID: 14678158 DOI: 10.1046/j.1365-2672.2003.02115.x] [Citation(s) in RCA: 54] [Impact Index Per Article: 2.7] [Reference Citation Analysis] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/20/2022]
Affiliation(s)
- K E Sapsford
- Center for Bioresource Development, George Mason University, Fairfax, VA, USA
| | | | | | | | | | | | | |
Collapse
|
34
|
Rodriguez-Mozaz S, Reder S, de Alda ML, Gauglitz G, Barceló D. Simultaneous multi-analyte determination of estrone, isoproturon and atrazine in natural waters by the RIver ANAlyser (RIANA), an optical immunosensor. Biosens Bioelectron 2004; 19:633-40. [PMID: 14709380 DOI: 10.1016/s0956-5663(03)00255-0] [Citation(s) in RCA: 60] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/27/2022]
Abstract
In most medical and environmental applications of biosensors, only single analytes are determined. However, the monitoring of several analytes is obviously preferable in order to gather more information about the sample under analysis. In line with this, different technologies are being developed to obtain multi-analyte sensors. In this paper, an analytical method for the simultaneous determination of three different contaminants-atrazine, isoproturon, and estrone-in natural waters by using an optical immunosensor prototype, the so-called "RIver ANAlyser" (RIANA), is described. RIANA is based on a rapid solid-phase fluoroimmunoassay that takes place at an optical transducer chip. The transducer surface is chemically modified with three analytes derivatives placed in different discrete locations. The sensor surface can be regenerated thus allowing the performance of several measurements with the same transducer. Each test cycle, including one regeneration step, is accomplished in 15 min. Detection limits achieved were 0.155, 0.046, and 0.084 microg/l, for atrazine, isoproturon, and estrone, respectively. Satisfactory repetition, with relative standard deviations between 1.06 and 6.98%, was obtained. Excluding a minor non-specifical binding of the isoproturon antibodies, no cross-reactivity effects were observed. Matrix effects were significant only in the case of wastewater samples. Biosensor measurements were validated using conventional liquid chromatography-mass spectrometry. The results obtained with both techniques were in good agreement.
Collapse
Affiliation(s)
- S Rodriguez-Mozaz
- Department of Environmental Chemistry, IIQAB-CSIC, C/Jordi Girona Salgado 18-26, 08034 Barcelona, Spain.
| | | | | | | | | |
Collapse
|
35
|
Taitt CR, Shubin YS, Angel R, Ligler FS. Detection of Salmonella enterica serovar typhimurium by using a rapid, array-based immunosensor. Appl Environ Microbiol 2004; 70:152-8. [PMID: 14711637 PMCID: PMC321280 DOI: 10.1128/aem.70.1.152-158.2004] [Citation(s) in RCA: 72] [Impact Index Per Article: 3.6] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/08/2003] [Accepted: 10/16/2003] [Indexed: 11/20/2022] Open
Abstract
The multianalyte array biosensor (MAAB) is a rapid analysis instrument capable of detecting multiple analytes simultaneously. Rapid (15-min), single-analyte sandwich immunoassays were developed for the detection of Salmonella enterica serovar Typhimurium, with a detection limit of 8 x 10(4) CFU/ml; the limit of detection was improved 10-fold by lengthening the assay protocol to 1 h. S. enterica serovar Typhimurium was also detected in the following spiked foodstuffs, with minimal sample preparation: sausage, cantaloupe, whole liquid egg, alfalfa sprouts, and chicken carcass rinse. Cross-reactivity tests were performed with Escherichia coli and Campylobacter jejuni. To determine whether the MAAB has potential as a screening tool for the diagnosis of asymptomatic Salmonella infection of poultry, chicken excretal samples from a private, noncommercial farm and from university poultry facilities were tested. While the private farm excreta gave rise to signals significantly above the buffer blanks, none of the university samples tested positive for S. enterica serovar Typhimurium without spiking; dose-response curves of spiked excretal samples from university-raised poultry gave limits of detection of 8 x 10(3) CFU/g.
Collapse
Affiliation(s)
- Chris Rowe Taitt
- Center for Bio/Molecular Science and Engineering, Naval Research Laboratory, Washington, D.C. 20375, USA.
| | | | | | | |
Collapse
|
36
|
Abstract
We report on a novel technique to develop an optical immunosensor based on fluorescence resonance energy transfer (FRET). IgG antibodies were labeled with acceptor fluorophores while one of three carrier molecules (protein A, protein G, or F(ab')2 fragment) was labeled with donor fluorophores. The carrier molecule was incubated with the antibody to allow specific binding to the Fc portion. The labeled antibody-protein complex was then exposed to specific and nonspecific antigens, and experiments were designed to determine the 'in solution' response. The paper reports the results of three different donor-acceptor FRET pairs, fluorescein isothiocyanate/tetramethylrhodamine isothiocyanate, Texas Red/Cy5, and Alexa Fluor 546/Alexa Fluor 594. The effects of the fluorophore to protein conjugation ratio (F/P ratio) and acceptor to donor fluorophore ratios between the antibody and protein (A/D ratio) were examined. In the presence of specific antigens, the antibodies underwent a conformational change, resulting in an energy transfer from the donor to the acceptor fluorophore as measured by a change in fluorescence. The non-specific antigens elicited little or no changes. The Alexa Fluor FRET pair demonstrated the largest change in fluorescence, resulting in a 35% change. The F/P and A/D ratio will affect the efficiency of energy transfer, but there exists a suitable range of A/D and F/P ratios for the FRET pairs. The feasibility of the FRET immunosensor technique was established; however, it will be necessary to immobilize the complexes onto optical substrates so that consistent trends can be obtained that would allow calibration plots.
Collapse
Affiliation(s)
- Darcy J Lichlyter
- Department of Biological Engineering, University of Missouri-Columbia, 250 Ag. Engineering Building, Columbia, MO 65211, USA
| | | | | |
Collapse
|
37
|
Shriver-Lake LC, Shubin YS, Ligler FS. Detection of staphylococcal enterotoxin B in spiked food samples. J Food Prot 2003; 66:1851-6. [PMID: 14572223 DOI: 10.4315/0362-028x-66.10.1851] [Citation(s) in RCA: 52] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/11/2022]
Abstract
Contamination of food with infectious agents, intentional or not, is a global concern with far-reaching economic and social impact. Staphylococcal enterotoxins are a major cause of food poisoning, but most methods for the identification of these agents in food require extensive pretreatment or concentration of the sample prior to analysis. The array biosensor was developed as a portable device for the simultaneous analysis of multiple complex samples for multiple targets with minimal sample preparation. In this study, we use an array biosensor to expand and improve on a staphylococcal enterotoxin B (SEB) assay with the ultimate intent of incorporating testing for SEB into a battery of sensitive and convenient assays for food safety validation. In addition to buffer studies, six different types of food samples, including beverages, homogenates of fruit and meat, and carcass washings, were spiked with SEB, incubated for at least 2 h to permit antigen sequestration, and assayed. For all samples, there were differences in fluorescence intensity, but 0.5 ng of SEB per ml could be detected in <20 min with little if any pretreatment and no sample preconcentration.
Collapse
Affiliation(s)
- Lisa C Shriver-Lake
- Center for Bio/Molecular Science and Engineering, Naval Research Laboratory, 4555 Overlook Avenue SW, Washington, DC 20375-5348, USA.
| | | | | |
Collapse
|
38
|
Askari MDF, Miller GH, Vo-Dinh T. Simultaneous detection of the tumor suppressor FHIT gene and protein using the multi-functional biochip. CANCER DETECTION AND PREVENTION 2003; 26:331-42. [PMID: 12518863 DOI: 10.1016/s0361-090x(02)00091-0] [Citation(s) in RCA: 11] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/23/2022]
Abstract
The tumor suppressor gene, fragile histidine triad (FHIT), encompasses the most common human chromosomal fragile site, at 3pl4.2. Detection of FHIT gene is important in cancer diagnostics since its alterations have been associated with several human cancers. A unique multi-functional biochip for simultaneous detection of FHIT DNA and FHIT protein on the same platform was applied. The design of the biochip is based on miniaturization of photodiodes, where functioning of multiple optical sensing elements, amplifiers, discriminators, and logic circuitry are integrated on a single IC board. Performance of biochip is based on biomolecular recognition processes using both DNA and protein bioreceptors, Cy5-labeled probes and laser excitation. Application of biochip for concurrent detection of various immobilized target DNA and protein molecules and multiplex of DNA and protein on the same microarray was accomplished. Linearity of biochip for quantitative measurements was demonstrated. Results demonstrated utility of this multi-functional biochip as a useful detection technology with applications in biological and clinical laboratories.
Collapse
Affiliation(s)
- Minoo D F Askari
- Advanced Monitoring Development Group, Life Sciences Division, Graduate School of Biomedical Sciences, Oak Ridge National Laboratory & University of Tennessee/Oak Ridge, Oak Ridge, TN 37831-6101, USA.
| | | | | |
Collapse
|
39
|
McBride MT, Gammon S, Pitesky M, O'Brien TW, Smith T, Aldrich J, Langlois RG, Colston B, Venkateswaran KS. Multiplexed liquid arrays for simultaneous detection of simulants of biological warfare agents. Anal Chem 2003; 75:1924-30. [PMID: 12713052 DOI: 10.1021/ac026379k] [Citation(s) in RCA: 123] [Impact Index Per Article: 5.9] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/29/2022]
Abstract
Liquid array-based multiplexed immunoassays designed for rapid, sensitive, specific, and simultaneous detection of multiple simulants of biological warfare agents have been developed. In both blind and standard laboratory trials, we demonstrate the simultaneous detection of four simulant agents from a single sample. The challenge agents comprise broad classes of pathogens (virus, protein toxins, bacterial spores, vegetative cells). Assay performance of each analyte was optimized, and dose-response curves and the limits of detection (LODs) for individual analytes are presented. Assay performance, including dynamic range, sensitivity, and LODs for liquid arrays and enzyme-linked immunosorbant assay were compared and are shown to be similar. Maximum assay sensitivity is obtained in approximately 1 h, and good sensitivity is achieved in as little as 30 min. Although the sample matrixes are very complex, even for highly multiplexed assays the samples do not exhibit evidence of nonspecific binding, demonstrating that the assays also have high specificity.
Collapse
Affiliation(s)
- Mary T McBride
- Lawrence Livermore National Laboratory, 7000 East Avenue, P.O. Box 808, Livermore, California 94550, USA
| | | | | | | | | | | | | | | | | |
Collapse
|
40
|
Sheehan AD, Quinn J, Daly S, Dillon P, O'Kennedy R. The Development of Novel Miniaturized Immuno-sensing Devices: A Review of a Small Technology with a Large Future. ANAL LETT 2003. [DOI: 10.1081/al-120018234] [Citation(s) in RCA: 43] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/03/2022]
|
41
|
Xu J, Grant SA, Pastel RL. Laser-guided direct writing: a novel method to deposit biomolecules for biosensors arrays. IEEE Trans Biomed Eng 2003; 50:126-8. [PMID: 12617535 DOI: 10.1109/tbme.2002.805461] [Citation(s) in RCA: 9] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/08/2022]
Abstract
In this paper, we present a potential biomolecular patterning method, laser-guided direct writing guidance (LGDW), which may be utilized to deposit organic and bioactive particles for biosensor arrays. The instrumentation and operation of the LGDW system is introduced and the system settings used to achieve deposition are reported. The biomolecule, avidin, was deposited onto a substrate using LGDW to evaluate the possible damage from the laser on the biomolecules. The functionality of avidin after laser-based guidance was examined by exposing the deposited avidin molecules to its ligand, biotin. The results show some avidin retained its affinity to biotin after LGDW demonstrating little damage to the biomolecules.
Collapse
Affiliation(s)
- Juntao Xu
- Department of Biological Engineering, University of Missouri-Columbia, 250 Ag. Bldg., Columbia, MO 65211, USA
| | | | | |
Collapse
|
42
|
Abstract
An array biosensor has been developed which uses an actively-cooled, charge-coupled device (CCD) imager. In an effort to save money and space, a complementary metal-oxide semiconductor (CMOS) camera and photodiode were tested as replacements for the cooled CCD imager. Different concentrations of CY5 fluorescent dye in glycerol were imaged using the three different detection systems with the same imaging optics. Signal discrimination above noise was compared for each of the three systems.
Collapse
Affiliation(s)
- Joel P Golden
- Naval Research Laboratory, Center for Bio/Molecular Science and Engineering, Code 6900, Washington, DC 20375-5348, USA.
| | | |
Collapse
|
43
|
Liron Z, Tender LM, Golden JP, Ligler FS. Voltage-induced inhibition of antigen-antibody binding at conducting optical waveguides. Biosens Bioelectron 2002; 17:489-94. [PMID: 11959469 DOI: 10.1016/s0956-5663(01)00320-7] [Citation(s) in RCA: 26] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/27/2022]
Abstract
Optical waveguides coated with electrically conducting indium-tin oxide (ITO) are demonstrated here as a new class of substrate for fluorescent immunosensors. These waveguides combine electrochemical control with evanescent excitation and image-based detection. Presented here are preliminary results utilizing these waveguides that demonstrate influence of waveguide voltage on antigen binding. Specifically, waveguide surfaces were bisected into electrically addressable halves, anti-ovalbumin immobilized in patterns on their surfaces, and a 1.3 V bias applied between waveguide halves in the presence of Cy5-labeled ovalbumin in 10 mM phosphate buffer (pH 7.4) containing 150 mM NaCl and 0.05% Tween-20. Fluorescence imaging indicated that binding of the antigen to positively biased waveguide halves was inhibited nearly 10-fold compared with negatively biased waveguide halves and unbiased controls. Furthermore, it is shown that ovalbumin binding to positively biased waveguide regions is regenerated after removal of applied voltage. These results suggest that electrochemical control of immunosensor substrates can be used as a possible strategy toward minimizing cross-reactive binding and/or nonspecific adsorption, immunosensor regeneration, and controlled binding.
Collapse
Affiliation(s)
- Zvi Liron
- George Mason University, Arlington, VA, USA
| | | | | | | |
Collapse
|
44
|
Naimushin AN, Soelberg SD, Nguyen DK, Dunlap L, Bartholomew D, Elkind J, Melendez J, Furlong CE. Detection of Staphylococcus aureus enterotoxin B at femtomolar levels with a miniature integrated two-channel surface plasmon resonance (SPR) sensor. Biosens Bioelectron 2002; 17:573-84. [PMID: 11959480 DOI: 10.1016/s0956-5663(02)00014-3] [Citation(s) in RCA: 146] [Impact Index Per Article: 6.6] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/27/2022]
Abstract
Surface plasmon resonance (SPR) biosensors offer the capability for continuous real-time monitoring. The commercial instruments available have been large in size, expensive, and not amenable to field applications. We report here an SPR sensor system based on a prototype two-channel system similar to the single channel Spreeta devices. This system is an ideal candidate for field use. The two-channel design provides a reference channel to compensate for bulk refractive index (RI), non-specific binding and temperature variations. The SPR software includes a calibration function that normalizes the response from both channels, thus enabling accurate referencing. In addition, a temperature-controlled enclosure utilizing a thermo-electric module based on the Peltier effect provides the temperature stability necessary for accurate measurements of RI. The complete SPR sensor system can be powered by a 12V battery. Pre-functionalized, disposable, gold-coated thin glass slides provide easily renewable sensor elements for the system. Staphylococcus aureus enterotoxin B (SEB), a small protein toxin was directly detectable at sub-nanomolar levels and with amplification at femtomolar levels. A regeneration procedure for the sensor surface allowed for over 60 direct detection cycles in a 1-month period.
Collapse
Affiliation(s)
- Alexei N Naimushin
- Department of Medicine, University of Washington, Seattle, WA 98195. USA
| | | | | | | | | | | | | | | |
Collapse
|
45
|
Ligler FS, Breimer M, Golden JP, Nivens DA, Dodson JP, Green TM, Haders DP, Sadik OA. Integrating waveguide biosensor. Anal Chem 2002; 74:713-9. [PMID: 11838701 DOI: 10.1021/ac015607s] [Citation(s) in RCA: 75] [Impact Index Per Article: 3.4] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/28/2022]
Abstract
A capillary biosensor is demonstrated which uses the waveguiding properties of the capillary to integrate the signal over an increased surface area without simultaneously increasing the background noise from the detector. This biosensor achieves limits of detection of 30-50 pg/mL in immunoassays using a diode laser for excitation and a PMT for detection. This is approximately 2 orders of magnitude greater sensitivity than was achieved using the same immunoassay reagents in a fiber optic biosensor or a planar array biosensor. Two different approaches to using the capillaries as immunosensors are described, either of which could be adapted for multianalyte sensing.
Collapse
Affiliation(s)
- Frances S Ligler
- Center for Bio/Molecular Science & Engineering, Naval Research Laboratory, Washington, DC 20375-5348, USA.
| | | | | | | | | | | | | | | |
Collapse
|
46
|
Abstract
INTRODUCTION Immunosensors are affinity ligand-based biosensor solid-state devices in which the immunochemical reaction is coupled to a transducer. The fundamental basis of all immunosensors is the specificity of the molecular recognition of antigens by antibodies to form a stable complex. This is similar to the immunoassay methodology. Immunosensors can be categorized based on the detection principle applied. The main developments are electrochemical, optical, and microgravimetric immunosensors. In contrast to immunoassay, modern transducer technology enables the label-free detection and quantification of the immune complex. METHODS The analysis of trace substances in environmental science, pharmaceutical and food industries is a challenge since many of these applications demand a continuous monitoring mode. The use of immunosensors in these applications is most appropriate. Similarly, a series of clinical problems may be solved by continuous monitoring of certain analytes. CONCLUSIONS Clinical chemists should take advantage of immunosensors in clinical diagnostics. There are many recent developments in the immunosensor field which have potential impacts. The future role of this technique in intralaboratory, as well as bedside testing, will become even more important as the clinical laboratory is faced with increasing pressure to contain costs.
Collapse
Affiliation(s)
- P B Luppa
- Institute for Clinical Chemistry and Pathobiochemistry, Klinikum rechts der Isar der Technischen Universität München, Ismaninger Str. 22, D-81675 Munich, Germany.
| | | | | |
Collapse
|
47
|
Sapsford KE, Liron Z, Shubin YS, Ligler FS. Kinetics of antigen binding to arrays of antibodies in different sized spots. Anal Chem 2001; 73:5518-24. [PMID: 11816582 DOI: 10.1021/ac015554e] [Citation(s) in RCA: 76] [Impact Index Per Article: 3.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/29/2022]
Abstract
A fluorescence-based array biosensor has been developed which can measure the binding kinetics of an antigen to an immobilized antibody in real time. A patterned array of antibodies immobilized on the surface of a planar waveguide was used to capture a Cy5-labeled antigen present in a solution that was continuously flowed over the surface. The CCD image of the waveguide was monitored continuously for 25 min. The resulting exponential rise in fluorescence signal was determined by image analysis software and fitted to a reaction-limited kinetics model, giving a kf of 3.6 x 10(5) M(-1) s(-1). Different spot sizes were then patterned on the surface of the waveguide using either a PDMS flow cell or laser exposure, producing width sizes ranging from 80 to 1145 microm. It was demonstrated that under flow conditions, the reduction of spot size did not alter the association rate of the antigen with immobilized antibody; however, as the spot width decreased to < 200 nm, the signal intensity also decreased.
Collapse
Affiliation(s)
- K E Sapsford
- Center for Bioresource Development, George Mason University, Fairfax, Virginia 22030-4444, USA
| | | | | | | |
Collapse
|
48
|
Krafft AE, Kulesh DA. Applying Molecular Biological Techniques to Detecting Biological Agents. Clin Lab Med 2001. [DOI: 10.1016/s0272-2712(18)30026-x] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/28/2022]
|
49
|
Dodson JM, Feldstein MJ, Leatzow DM, Flack LK, Golden JP, Ligler FS. Fluidics cube for biosensor miniaturization. Anal Chem 2001; 73:3776-80. [PMID: 11510847 DOI: 10.1021/ac010168i] [Citation(s) in RCA: 17] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/29/2022]
Abstract
To create a small, portable, fully automated biosensor, a compact means of fluid handling is required. We designed, manufactured, and tested a "fluidics cube" for such a purpose. This cube, made of thermoplastic, contains reservoirs and channels for liquid samples and reagents and operates without the use of any internal valves or meters; it is a passive fluid circuit that relies on pressure relief vents to control fluid movement. We demonstrate the ability of pressure relief vents to control fluid movement and show how to simply manufacture or modify the cube. Combined with the planar array biosensor developed at the Naval Research Laboratory, it brings us one step closer to realizing our goal of a handheld biosensor capable of analyzing multiple samples for multiple analytes.
Collapse
Affiliation(s)
- J M Dodson
- Center for Bio/Molecular Science & Engineering, Naval Research Laboratory, Washington, DC 20375-5348, USA
| | | | | | | | | | | |
Collapse
|
50
|
|