1
|
Sadighi R, de Kleijne VH, Vido M, Zioga E, Wouters S, Lubbers K, Haselberg R, Gargano AFG, Somsen GW. Online multimethod platform for comprehensive characterization of monoclonal antibodies in cell culture fluid from injection of crude sample - Incorporation of middle-up and bottom-up workflows. Anal Chim Acta 2025; 1353:343943. [PMID: 40221213 DOI: 10.1016/j.aca.2025.343943] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/30/2024] [Revised: 02/16/2025] [Accepted: 03/13/2025] [Indexed: 04/14/2025]
Abstract
BACKGROUND Determination of critical quality attributes (CQAs) of pharmaceutical monoclonal antibodies (mAbs) is an essential part of quality control. Commonly, for each CQA, a separate analytical method and setup is required, making assessment of multiple CQAs time-consuming and labour-intensive. This typically involves offline purification and diverse protein digestion steps, in combination with multiple liquid-chromatographic modes. We developed an integrated, fully online multidimensional platform for direct analysis of mAbs in cell culture fluid (CCF) at an intact, subunit and peptide level from a single injection. RESULTS This paper focuses on the online middle-up and bottom-up workflows. The platform combines Protein A affinity chromatography (ProtA), immobilized enzyme reactors (IMERs), reversed-phase liquid chromatography (RPLC) and high-resolution mass spectrometry (MS) for characterization of mAbs. Online ProtA was used to isolate mAbs directly from CCF. Subsequent online digestion of isolated mAb was accomplished by IMERs featuring either the proteases IdeS or trypsin. Between ProtA and IMERs, buffer exchange and pH adjustment were achieved using a strong cation-exchange (SCX) trap column. RPLC-MS analysis of F(ab)'2 and Fc/2 fragments obtained after IdeS digestion provided information on mAb glycoform compositions and the potential presence of PTMs and subunit variants. RPLC-MS/MS analysis of trypsin-digested peptides provided over 95 % coverage of the mAb's amino acid sequence, but also identification and localization of modifications related to e.g. oxidation and deamidation. Comparisons with established offline methods were made. The overall capacity of the system to perform intact, middle-, and bottom-up analyses in parallel from a single injection is demonstrated for an industrially-relevant mAb in CCF. SIGNIFICANCE The developed multidimensional platform enables the simultaneous characterization of multiple fractions from a single ProtA-isolated mAb band at intact, middle-up, or bottom-up level using various LC modes at a substantially reduced analysis time.
Collapse
Affiliation(s)
- Raya Sadighi
- Division of Bioanalytical Chemistry, Department of Chemistry and Pharmaceutical Sciences, Amsterdam Institute of Molecular and Life Sciences, Vrije Universiteit Amsterdam, De Boelelaan 1085, 1081, HV Amsterdam, the Netherlands; Centre for Analytical Sciences Amsterdam (CASA), the Netherlands.
| | - Vera H de Kleijne
- Division of Bioanalytical Chemistry, Department of Chemistry and Pharmaceutical Sciences, Amsterdam Institute of Molecular and Life Sciences, Vrije Universiteit Amsterdam, De Boelelaan 1085, 1081, HV Amsterdam, the Netherlands; Centre for Analytical Sciences Amsterdam (CASA), the Netherlands
| | - Marek Vido
- Department of Chemistry, Faculty of Science, Masaryk University, Kamenice 5, 62500, Brno, Czech Republic
| | - Eirini Zioga
- Division of Bioanalytical Chemistry, Department of Chemistry and Pharmaceutical Sciences, Amsterdam Institute of Molecular and Life Sciences, Vrije Universiteit Amsterdam, De Boelelaan 1085, 1081, HV Amsterdam, the Netherlands; Centre for Analytical Sciences Amsterdam (CASA), the Netherlands
| | - Sam Wouters
- Agilent Technologies, R&D and Marketing GmbH, Hewlett-Packard-Strasse 8, 76337 Waldbronn, Germany
| | - Karin Lubbers
- Polpharma Biologics Utrecht B.V., Yalelaan 46, 3584, CM Utrecht, the Netherlands
| | - Rob Haselberg
- Division of Bioanalytical Chemistry, Department of Chemistry and Pharmaceutical Sciences, Amsterdam Institute of Molecular and Life Sciences, Vrije Universiteit Amsterdam, De Boelelaan 1085, 1081, HV Amsterdam, the Netherlands; Centre for Analytical Sciences Amsterdam (CASA), the Netherlands
| | - Andrea F G Gargano
- Centre for Analytical Sciences Amsterdam (CASA), the Netherlands; Analytical Chemistry Group, Van't Hoff Institute for Molecular Sciences, University of Amsterdam, PO Box 94720, 1090, GE Amsterdam, the Netherlands
| | - Govert W Somsen
- Division of Bioanalytical Chemistry, Department of Chemistry and Pharmaceutical Sciences, Amsterdam Institute of Molecular and Life Sciences, Vrije Universiteit Amsterdam, De Boelelaan 1085, 1081, HV Amsterdam, the Netherlands; Centre for Analytical Sciences Amsterdam (CASA), the Netherlands
| |
Collapse
|
2
|
Low KN, Kok YJ, Tate S, Bi X. Multilevel─Intact, Subunits, and Peptides─Characterization of Antibody-Based Therapeutics by a Single-Column LC-MS Setup. Anal Chem 2025; 97:5118-5125. [PMID: 39999080 DOI: 10.1021/acs.analchem.4c06350] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/27/2025]
Abstract
A comprehensive characterization of biotherapeutics, mandated by regulatory authorities, requires analyses of a protein drug at multiple structure levels. Such multilevel characterization can be performed by mass spectrometry (MS), with established conventional MS-based assays of product quality attributes (PQAs) comprising intact protein and subunit middle-up MS with analytes resolved on a C4 column, and bottom-up peptide mapping with analytes resolved on a C18 column. Recent advances in MS have facilitated the increasing use of middle-down analysis, expanding the qualitative analytical capability of MS for protein characterization. Recent studies using less-retentive reversed-phase LC in bottom-up MS also offer an opportunity for streamlining equipment configuration to a single-column LC-MS setup for multilevel characterization of therapeutic proteins. In this study, we developed a robust middle-down LC-MS method on a ZenoTOF 7600 and evaluated a C4 LC-MS setup for the characterization of NISTmAb, RG7221 bispecific antibody (bsAb), and Fc-fusion etanercept by intact protein, subunit middle-up/down, and bottom-up analyses. Successful multilevel characterization of the analytes using C4 LC-MS was demonstrated; notably, high sequence coverage and comprehensive post-translational modification profiling, including the mapping of all 13 O- and 3 N-glycosylation sites on etanercept in a single run, were obtained by bottom-up C4 LC-MS. This is also the first report on middle-down analysis of the major etanercept TNFR and Fc subunit glycoforms. A streamlined single-column LC-MS setup will enable more robust and efficient MS workflows for PQA assessment and simplify the integration of an LC-MS analyzer as a process analytical technology instrument for biopharma applications.
Collapse
Affiliation(s)
- Kia-Ngee Low
- Bioprocessing Technology Institute (BTI), Agency for Science, Technology and Research (A*STAR), 20 Biopolis Way, #06-01 Centros, Singapore 138668, Singapore
| | - Yee-Jiun Kok
- Bioprocessing Technology Institute (BTI), Agency for Science, Technology and Research (A*STAR), 20 Biopolis Way, #06-01 Centros, Singapore 138668, Singapore
| | | | - Xuezhi Bi
- Bioprocessing Technology Institute (BTI), Agency for Science, Technology and Research (A*STAR), 20 Biopolis Way, #06-01 Centros, Singapore 138668, Singapore
- Duke-NUS Medical School, Singapore 169857, Singapore
- Food, Chemical and Biotechnology Cluster, Singapore Institute of Technology, Singapore 138683, Singapore
| |
Collapse
|
3
|
Sarin D, Kumar S, Rathore AS. Offline Coupling of Hydrophobic Interaction Chromatography-Capillary Zone Electrophoresis for Monitoring Charge-Based Heterogeneity of Recombinant Monoclonal Antibodies. Electrophoresis 2024; 45:1927-1938. [PMID: 39402848 DOI: 10.1002/elps.202400158] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/15/2024] [Revised: 09/11/2024] [Accepted: 09/23/2024] [Indexed: 12/22/2024]
Abstract
A holistic understanding of the charge heterogeneity in monoclonal antibodies (mAbs) is paramount for ensuring acceptable product quality. Hence, biotherapeutic manufacturers are expected to thoroughly characterize their products via advanced analytical techniques. Recently, two-dimensional liquid chromatography (2DLC) methods have gained popularity for resolving complex charged species. Capillary electrophoresis (CE) is regarded as a sensitive and faster tool for charged species estimation in biotherapeutics. In this study, we aim to combine the separation power of chromatographic and electrophoretic tools (liquid chromatography [LC]-CE) so as to achieve maximum resolution of mAb charge variants. Hydrophobic interaction chromatography (HIC) has been used as the preferred LC mode with CE for achieving successful separation of both charge and hydrophobic variants for two of the mAbs (trastuzumab and rituximab). The standalone HIC and capillary zone electrophoresis (CZE) methods separated 4 hydrophobic variants and 7 charge variants for each mAb, whereas the 2DLC method separated 10 and 11 variants for mAbs A and B. On the other hand, the HIC-CZE-UV method resolved 29 variants in mAb A and 23 variants in mAb B. The reproducibility of the HIC-CZE-UV method was demonstrated by % change in values of retention time (RT) and peak area as <5% (mAb A), <3% (mAb B), and <12% (for both mAbs), respectively. Thus, the utility of the proposed LC-CE method for characterization of mAb charge variants has been displayed.
Collapse
Affiliation(s)
- Deepika Sarin
- Department of Chemical Engineering, Indian Institute of Technology Delhi, New Delhi, India
| | - Sunil Kumar
- Department of Chemical Engineering, Indian Institute of Technology Delhi, New Delhi, India
| | - Anurag S Rathore
- Department of Chemical Engineering, Indian Institute of Technology Delhi, New Delhi, India
| |
Collapse
|
4
|
Böttinger K, Regl C, Schäpertöns V, Rapp E, Wohlschlager T, Huber CG. "Small is beautiful" - Examining reliable determination of low-abundant therapeutic antibody glycovariants. J Pharm Anal 2024; 14:100982. [PMID: 39850237 PMCID: PMC11755342 DOI: 10.1016/j.jpha.2024.100982] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/09/2024] [Revised: 03/21/2024] [Accepted: 04/23/2024] [Indexed: 01/25/2025] Open
Abstract
Glycans associated with biopharmaceutical drugs play crucial roles in drug safety and efficacy, and therefore, their reliable detection and quantification is essential. Our study introduces a multi-level quantification approach for glycosylation analysis in monoclonal antibodies (mAbs), focusing on minor abundant glycovariants. Mass spectrometric data is evaluated mainly employing open-source software tools. Released N-glycan and glycopeptide data form the basis for integrating information across different structural levels up to intact glycoproteins. Comprehensive comparison showed that indeed, variations across structural levels were observed especially for minor abundant species. Utilizing modification finder (MoFi), a tool for annotating mass spectra of intact proteins, we quantify isobaric glycosylation variants at the intact protein level. Our workflow's utility is demonstrated on NISTmAb, rituximab and adalimumab, profiling their minor abundant variants for the first time across diverse structural levels. This study enhances understanding and accessibility in glycosylation analysis, spotlighting minor abundant glycovariants in therapeutic antibodies.
Collapse
Affiliation(s)
- Katharina Böttinger
- Department of Biosciences and Medical Biology, Bioanalytical Research Labs, University of Salzburg, Salzburg, 5020, Austria
| | - Christof Regl
- Department of Biosciences and Medical Biology, Bioanalytical Research Labs, University of Salzburg, Salzburg, 5020, Austria
- Center for Tumorbiology and Immunology (CTBI), University of Salzburg, Salzburg, 5020, Austria
| | - Veronika Schäpertöns
- Department of Biosciences and Medical Biology, Bioanalytical Research Labs, University of Salzburg, Salzburg, 5020, Austria
| | - Erdmann Rapp
- glyXera GmbH, Magdeburg, Sachsen-Anhalt, 39014, Germany
- Max Planck Institute for Dynamics of Complex Technical Systems, Magdeburg, 39106, Germany
| | - Therese Wohlschlager
- Department of Biosciences and Medical Biology, Bioanalytical Research Labs, University of Salzburg, Salzburg, 5020, Austria
| | - Christian G. Huber
- Department of Biosciences and Medical Biology, Bioanalytical Research Labs, University of Salzburg, Salzburg, 5020, Austria
- Center for Tumorbiology and Immunology (CTBI), University of Salzburg, Salzburg, 5020, Austria
| |
Collapse
|
5
|
Senini I, Tengattini S, Rinaldi F, Massolini G, Gstöttner C, Reusch D, Donini M, Marusic C, van Veelen PA, Domínguez-Vega E, Wuhrer M, Temporini C, Nicolardi S. Direct glycosylation analysis of intact monoclonal antibodies combining ESI MS of glycoforms and MALDI-in source decay MS of glycan fragments. Commun Chem 2024; 7:203. [PMID: 39261598 PMCID: PMC11390885 DOI: 10.1038/s42004-024-01297-x] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/19/2024] [Accepted: 09/03/2024] [Indexed: 09/13/2024] Open
Abstract
Monoclonal antibody (mAb) glycoengineering has the potential to improve the efficacy of biopharmaceuticals by fine-tuning specific biological properties. Glycosylation analysis is key to monitoring the glycoengineering process. Various mass spectrometry (MS)-based methods are available to characterize mAb glycosylation at different structural levels, but comprehensive analysis is typically time-consuming and costly. Here, we present an approach that combines conventional intact mass measurement of glycoforms by direct infusion ESI-MS with an advanced MALDI-in-source decay FT-ICR MS method for direct analysis of glycans in intact mAbs, without the need for enzymatic release and separation. Using a sodium-doped MALDI matrix, glycans were directly released as ISD fragment ions from the intact mAbs during the ionization process. Measurement of 0,2A fragment signals yielded reproducible glycan profiles that were consistent with conventional methods, yet was achieved with unprecedented speed, providing complementary information to that obtained through intact mass measurement. The methods were applied to standard and glycoengineered trastuzumab and rituximab, allowing rapid glycosylation profiling and structural analysis of glycans by tandem MS of selected ISD fragment ions. This fast approach can facilitate the early-phase development of glycoengineering processes by constraining further in-depth analyses. We envision a broader applicability in studies focused on glycosylation changes in mAbs.
Collapse
Affiliation(s)
- Isabella Senini
- University of Pavia, via Taramelli 12, Pavia, Italy
- Leiden University Medical Center, Albinusdreef 2, Leiden, The Netherlands
| | | | | | | | | | - Dietmar Reusch
- Pharma Technical Development Penzberg, Roche Diagnostics GmbH, Penzberg, Germany
| | - Marcello Donini
- Laboratory of Biotechnology, ENEA Casaccia Research Center, Via Anguillarese 301, Roma, Italy
| | - Carla Marusic
- Laboratory of Biotechnology, ENEA Casaccia Research Center, Via Anguillarese 301, Roma, Italy
| | - Peter A van Veelen
- Leiden University Medical Center, Albinusdreef 2, Leiden, The Netherlands
| | | | - Manfred Wuhrer
- Leiden University Medical Center, Albinusdreef 2, Leiden, The Netherlands
| | | | - Simone Nicolardi
- Leiden University Medical Center, Albinusdreef 2, Leiden, The Netherlands.
| |
Collapse
|
6
|
Sarin D, Kumar S, Rathore AS. Titer and charge-based heterogeneity multiattribute monitoring of mAbs in cell culture harvest using 2D ProA CEX MS. Talanta 2024; 276:126232. [PMID: 38749159 DOI: 10.1016/j.talanta.2024.126232] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/20/2024] [Revised: 04/24/2024] [Accepted: 05/07/2024] [Indexed: 06/14/2024]
Abstract
Robust monitoring of heterogeneity in biopharmaceutical development is crucial for producing safe and efficacious biotherapeutic products. Multiattribute monitoring (MAM) has emerged as an efficient tool for monitoring of mAb heterogeneities like deamidation, sialylation, glycosylation, and oxidation. Conventional biopharma analysis during mAb development relies on use of one-dimensional methods for monitoring titer and charge-based heterogeneity using non-volatile solvents without direct coupling with mass spectrometry (MS). This approach requires analysis of mAb harvest by ProA for titer estimation followed by separate cation exchange chromatography (CEX) analysis of the purified sample for estimating charge-based heterogeneity. This can take up to 60-90 min due to the required fraction collection and buffer exchange steps. In this work, a native two-dimensional liquid chromatography (2DLC) mass spectrometry method has been developed with Protein A chromatography in the first dimension for titer estimation and cation exchange chromatography (CEX) in the second dimension for charge variant analysis. The method uses volatile salts for both dimensions and enables easy coupling to MS. The proposed 2DLC method exhibits a charge variant profile that is similar to that observed via the traditional methods and takes only 15 min for mass identification of each variant. A total of six charge variants were separated by the CEX analysis after titer estimation, including linearity assessment from 5 μg to 160 μg of injected mAb sample. The proposed method successfully estimated charge variants for the mAb innovator and 4 of its biosimilars, showcasing its applicability for biosimilarity exercises. Hence, the 2D ProA CEX MS method allows direct titer and charge variant estimation of mAbs in a single workflow.
Collapse
Affiliation(s)
- Deepika Sarin
- Department of Chemical Engineering, Indian Institute of Technology, Delhi, Hauz Khas, New Delhi, 110016, India
| | - Sunil Kumar
- Department of Chemical Engineering, Indian Institute of Technology, Delhi, Hauz Khas, New Delhi, 110016, India
| | - Anurag S Rathore
- Department of Chemical Engineering, Indian Institute of Technology, Delhi, Hauz Khas, New Delhi, 110016, India.
| |
Collapse
|
7
|
Rauniyar N, Khetani J, Han X. Comparative analysis of Herceptin N-Linked glycosylation by HILIC-FLD and LC-MS/MS methods. J Pharm Biomed Anal 2024; 244:116123. [PMID: 38554555 DOI: 10.1016/j.jpba.2024.116123] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/20/2023] [Revised: 02/26/2024] [Accepted: 03/17/2024] [Indexed: 04/01/2024]
Abstract
Monoclonal antibodies like Herceptin play a pivotal role in modern therapeutics, with their glycosylation patterns significantly influencing their bioactivity. To characterize the N-glycan profile and their relative abundance in Herceptin, we employed two analytical methods: hydrophilic interaction chromatography with fluorescence detection (HILIC-FLD) for released glycans and liquid chromatography tandem mass spectrometry (LC-MS/MS) for glycopeptides. Our analysis included 21 European Union (EU)-Herceptin lots and 14 United States (US)-Herceptin lots. HILIC-FLD detected 25 glycan species, including positional isomers, revealing comparable chromatographic profiles for both EU and US lots. On the other hand, LC-MS/MS identified 26 glycoforms within the glycopeptide EEQYNSTYR. Both methods showed that a subset of glycans dominated the total abundance. Notably, EU-Herceptin lots with an expiration date of October 2022 exhibited increased levels of afucosylated and high mannose N-glycans. Our statistical comparisons showed that the difference in quantitative results between HILIC-FLD and LC-MS/MS is significant, indicating that the absolute quantitative values depend on the choice of the analytical method. However, despite these differences, both methods demonstrated a strong correlation in relative glycan proportions. This study contributes to the comprehensive analysis of Herceptin's glycosylation, offering insights into the influence of analytical methods on glycan quantification and providing valuable information for the biopharmaceutical industry.
Collapse
Affiliation(s)
- Navin Rauniyar
- Tanvex BioPharma USA, Inc, 10394 Pacific Center Ct, San Diego, CA 92121, USA.
| | - Joy Khetani
- Tanvex BioPharma USA, Inc, 10394 Pacific Center Ct, San Diego, CA 92121, USA
| | - Xuemei Han
- Tanvex BioPharma USA, Inc, 10394 Pacific Center Ct, San Diego, CA 92121, USA
| |
Collapse
|
8
|
Gupta S, Schöneich C, Rathore AS. Assessment of change in the basic variants composition of trastuzumab during dilution in saline for administration. Eur J Pharm Biopharm 2024; 199:114295. [PMID: 38636881 DOI: 10.1016/j.ejpb.2024.114295] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/26/2023] [Revised: 04/01/2024] [Accepted: 04/15/2024] [Indexed: 04/20/2024]
Abstract
Postproduction handling of drug products during preparation or clinical use may affect the structure and efficacy of the drug and perhaps remain unnoticed. Since chemical modifications can impact the product's structure, stability, and biological activity, this study investigates the impact of elevated temperature and subtle shift in pH on the drug product post-dilution in saline. The mAb sample diluted in saline for administration was stressed at elevated temperature and slightly acidic pH condition. Extended stability studies were performed and monitored for size and charge heterogeneity. Size heterogeneity shows no significant changes, whereas charge heterogeneity shows an increase in basic variants and a reduction in main species. Further, basic variants were isolated and characterized to identify the type and site of chemical modification. Intact mass analysis and peptide mapping identify that the basic variants were attributed mainly to the isomerization of HC Asp102 into iso-Asp or its succinimide intermediate. Four basic variants were found to exhibit similar structural properties as the main and control samples. However, basic variants showed reduced binding affinity to HER2 receptor, while there was no significant difference in FcRn binding. The results indicate that modification in the HC Asp102, which is present in the CDR, affects antigen binding and thus can influence the potency of the drug product. Hence, with the conventional stability studies required to license the drug product, including in-use or extended stability studies to mimic the postproduction handling would be desirable.
Collapse
Affiliation(s)
- Surbhi Gupta
- Department of Chemical Engineering, Indian Institute of Technology Delhi,New Delhi 110016, India
| | | | - Anurag S Rathore
- Department of Chemical Engineering, Indian Institute of Technology Delhi,New Delhi 110016, India.
| |
Collapse
|
9
|
Schairer J, Römer J, Lang D, Neusüß C. CE-MS/MS and CE-timsTOF to separate and characterize intramolecular disulfide bridges of monoclonal antibody subunits and their application for the assessment of subunit reduction protocols. Anal Bioanal Chem 2024; 416:1599-1612. [PMID: 38296860 PMCID: PMC10899284 DOI: 10.1007/s00216-024-05161-8] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/08/2023] [Revised: 01/15/2024] [Accepted: 01/17/2024] [Indexed: 02/02/2024]
Abstract
Characterization at the subunit level enables detailed mass spectrometric characterization of posttranslational modifications (PTMs) of monoclonal antibodies (mAbs). The implemented reduction often leaves the intramolecular disulfide bridges intact. Here, we present a capillary electrophoretic (CE) method based on a neutral-coated capillary for the separation of immunoglobulin G-degrading enzyme of Streptococcus pyogenes (IdeS) digested and reduced mAb subunits followed by mass spectrometry (MS), MS/MS identification, and trapped ion mobility mass spectrometry (timsTOF). Our CE approach enables the separation of (i) different subunit moieties, (ii) various reduction states, and (iii) positional isomers of these partly reduced subunit moieties. The location of the remaining disulfide bridges can be determined by middle-down electron transfer higher energy collisional dissociation (EThcD) experiments. All these CE-separated variants show differences in ion mobility in the timsTOF measurements. Applying the presented CE-MS/MS method, reduction parameters such as the use of chaotropic salts were studied. For the investigated antibodies, urea improved the subunit reduction significantly, whereas guanidine hydrochloride (GuHCl) leads to multiple signals of the same subunit in the CE separation. The presented CE-MS method is a powerful tool for the disulfide-variant characterization of mAbs on the subunit level. It enables understanding disulfide bridge reduction processes in antibodies and potentially other proteins.
Collapse
Affiliation(s)
- Jasmin Schairer
- Faculty of Chemistry, Aalen University, Aalen, Germany
- Faculty of Science, University of Tübingen, Tübingen, Germany
| | | | | | | |
Collapse
|
10
|
Helms A, Brodbelt JS. Mass Spectrometry Strategies for O-Glycoproteomics. Cells 2024; 13:394. [PMID: 38474358 PMCID: PMC10930906 DOI: 10.3390/cells13050394] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/23/2024] [Revised: 02/19/2024] [Accepted: 02/23/2024] [Indexed: 03/14/2024] Open
Abstract
Glycoproteomics has accelerated in recent decades owing to numerous innovations in the analytical workflow. In particular, new mass spectrometry strategies have contributed to inroads in O-glycoproteomics, a field that lags behind N-glycoproteomics due to several unique challenges associated with the complexity of O-glycosylation. This review will focus on progress in sample preparation, enrichment strategies, and MS/MS techniques for the identification and characterization of O-glycoproteins.
Collapse
Affiliation(s)
| | - Jennifer S. Brodbelt
- Department of Chemistry, The University of Texas at Austin, Austin, TX 78712, USA;
| |
Collapse
|
11
|
Lai YH, Wang YS. Advances in high-resolution mass spectrometry techniques for analysis of high mass-to-charge ions. MASS SPECTROMETRY REVIEWS 2023; 42:2426-2445. [PMID: 35686331 DOI: 10.1002/mas.21790] [Citation(s) in RCA: 8] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 09/06/2021] [Revised: 01/27/2022] [Accepted: 04/07/2022] [Indexed: 06/15/2023]
Abstract
A major challenge in modern mass spectrometry (MS) is achieving high mass resolving power and accuracy for precision analyses in high mass-to-charge (m/z) regions. To advance the capability of MS for increasingly demanding applications, understanding limitations of state-of-the-art techniques and their status in applied sciences is essential. This review summarizes important instruments in high-resolution mass spectrometry (HRMS) and related advances to extend their working range to high m/z regions. It starts with an overview of HRMS techniques that provide adequate performance for macromolecular analysis, including Fourier-transform, time-of-flight (TOF), quadrupole-TOF, and related data-processing techniques. Methodologies and applications of HRMS for characterizing macromolecules in biochemistry and material sciences are summarized, such as top-down proteomics, native MS, drug discovery, structural virology, and polymer analyses.
Collapse
Affiliation(s)
- Yin-Hung Lai
- Genomics Research Center, Academia Sinica, Taipei, Taiwan, R.O.C
- Department of Chemical Engineering, National United University, Miaoli, Taiwan, R.O.C
- Institute of Food Safety and Health Risk Assessment, National Yang Ming Chiao Tung University, Taipei, Taiwan, R.O.C
| | - Yi-Sheng Wang
- Genomics Research Center, Academia Sinica, Taipei, Taiwan, R.O.C
| |
Collapse
|
12
|
Révész Á, Hevér H, Steckel A, Schlosser G, Szabó D, Vékey K, Drahos L. Collision energies: Optimization strategies for bottom-up proteomics. MASS SPECTROMETRY REVIEWS 2023; 42:1261-1299. [PMID: 34859467 DOI: 10.1002/mas.21763] [Citation(s) in RCA: 20] [Impact Index Per Article: 10.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 06/11/2021] [Revised: 11/17/2021] [Accepted: 11/17/2021] [Indexed: 06/07/2023]
Abstract
Mass-spectrometry coupled to liquid chromatography is an indispensable tool in the field of proteomics. In the last decades, more and more complex and diverse biochemical and biomedical questions have arisen. Problems to be solved involve protein identification, quantitative analysis, screening of low abundance modifications, handling matrix effect, and concentrations differing by orders of magnitude. This led the development of more tailored protocols and problem centered proteomics workflows, including advanced choice of experimental parameters. In the most widespread bottom-up approach, the choice of collision energy in tandem mass spectrometric experiments has outstanding role. This review presents the collision energy optimization strategies in the field of proteomics which can help fully exploit the potential of MS based proteomics techniques. A systematic collection of use case studies is then presented to serve as a starting point for related further scientific work. Finally, this article discusses the issue of comparing results from different studies or obtained on different instruments, and it gives some hints on methodology transfer between laboratories based on measurement of reference species.
Collapse
Affiliation(s)
- Ágnes Révész
- MS Proteomics Research Group, Institute of Organic Chemistry, Research Centre for Natural Sciences, Budapest, Hungary
| | - Helga Hevér
- Chemical Works of Gedeon Richter Plc, Budapest, Hungary
| | - Arnold Steckel
- Department of Analytical Chemistry, MTA-ELTE Lendület Ion Mobility Mass Spectrometry Research Group, Institute of Chemistry, ELTE Eötvös Loránd University, Budapest, Hungary
| | - Gitta Schlosser
- Department of Analytical Chemistry, MTA-ELTE Lendület Ion Mobility Mass Spectrometry Research Group, Institute of Chemistry, ELTE Eötvös Loránd University, Budapest, Hungary
| | - Dániel Szabó
- MS Proteomics Research Group, Institute of Organic Chemistry, Research Centre for Natural Sciences, Budapest, Hungary
| | - Károly Vékey
- MS Proteomics Research Group, Institute of Organic Chemistry, Research Centre for Natural Sciences, Budapest, Hungary
| | - László Drahos
- MS Proteomics Research Group, Institute of Organic Chemistry, Research Centre for Natural Sciences, Budapest, Hungary
| |
Collapse
|
13
|
Kumar S, Savane TS, Rathore AS. Multiattribute Monitoring of Aggregates and Charge Variants of Monoclonal Antibody through Native 2D-SEC-MS-WCX-MS. JOURNAL OF THE AMERICAN SOCIETY FOR MASS SPECTROMETRY 2023. [PMID: 37327380 DOI: 10.1021/jasms.2c00325] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/18/2023]
Abstract
Monitoring of critical quality attributes such as size and charge-related heterogeneities is essential for biopharmaceutical manufacturers. Size-exclusion chromatography (SEC) is the preferred analytical technique for the quantification of aggregates and fragments in the product, whereas weak-cation exchange chromatography (WCX) is widely used for the characterization of charge variants of biotherapeutic products, in particular monoclonal antibodies (mAbs). Multiattribute monitoring offers the ability to monitor these attributes in a single run flow using two-dimensional liquid chromatography (2D-LC). Typically, in this approach, only the second-dimension samples are directly analyzed through mass spectrometry, as the first dimension has limitations concerning direct coupling with mass spectrometry. In the present study, a novel 2D-SEC-MS/WCX-MS workflow has been proposed, in which chromatography of both dimensions (D1 and D2) was directly coupled with mass spectrometry, through which size-related and charge-related variants of monoclonal antibody mAb A were analyzed simultaneously in their native form. In comparison to stand-alone SEC and WCX methods, this method enables simultaneous analysis of size and charge variants in a single workflow without manual intervention, allowing analysis of low abundant variants. Further, this method has 75% less sample requirement and a shorter analysis time (25 min vs 90 min) when size and charge variants were analyzed individually. The proposed native 2D-LC-MS workflow was used to analyze a stressed sample of mAb A, in which D1 analysis revealed the presence of aggregates (8-20%), which were primarily dimers, whereas D2 analysis showed an increment in acidic variants (9-21%).
Collapse
Affiliation(s)
- Sunil Kumar
- Department of Chemical Engineering, Indian Institute of Technology Delhi, Hauz Khas, New Delhi 110016, India
| | - Tushar Sharad Savane
- Department of Chemical Engineering, Indian Institute of Technology Delhi, Hauz Khas, New Delhi 110016, India
| | - Anurag S Rathore
- Department of Chemical Engineering, Indian Institute of Technology Delhi, Hauz Khas, New Delhi 110016, India
| |
Collapse
|
14
|
Gabant G, Stekovic M, Nemcic M, Pinêtre J, Cadene M. A sDOE (Simple Design-of-Experiment) Approach for Parameter Optimization in Mass Spectrometry. Part 1. Parameter Selection and Interference Effects in Top-Down ETD Fragmentation of Proteins in a UHR-QTOF Instrument. JOURNAL OF THE AMERICAN SOCIETY FOR MASS SPECTROMETRY 2023; 34:27-35. [PMID: 36479974 DOI: 10.1021/jasms.2c00215] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/17/2023]
Abstract
Design-of-experiment (DOE) approaches, originally conceived by Fischer, are widely applied in industry, particularly in the context of production for which they have been greatly expended. In a research and development context, DOE can be of great use for method development. Specifically, DOE can greatly speed up instrument parameter optimization by first identifying parameters that are critical to a given outcome, showing parameter interdependency where it occurs and accelerating optimization of said parameters using matrices of experimental conditions. While DOE approaches have been applied in mass spectrometry experiments, they have so far failed to gain widespread adoption. This could be attributed to the fact that DOE can get quite complex and daunting to the everyday user. Here we make the case that a subset of DOE tools, hereafter called SimpleDOE (sDOE), can make DOE accessible and useful to the Mass Spectrometry community at large. We illustrate the progressive gains from a purely manual approach to sDOE through a stepwise optimization of parameters affecting the efficiency of top-down ETD fragmentation of proteins on a high-resolution Q-TOF mass spectrometer, where the aim is to maximize sequence coverage of fragmentation events.
Collapse
Affiliation(s)
- Guillaume Gabant
- Centre de Biophysique Moléculaire, UPR4301, CNRS, affiliated to Université d'Orléans, Rue Charles Sadron, Orléans45071 Cedex 2, France
| | - Martin Stekovic
- Centre de Biophysique Moléculaire, UPR4301, CNRS, affiliated to Université d'Orléans, Rue Charles Sadron, Orléans45071 Cedex 2, France
| | - Matej Nemcic
- Centre de Biophysique Moléculaire, UPR4301, CNRS, affiliated to Université d'Orléans, Rue Charles Sadron, Orléans45071 Cedex 2, France
| | - Justine Pinêtre
- Centre de Biophysique Moléculaire, UPR4301, CNRS, affiliated to Université d'Orléans, Rue Charles Sadron, Orléans45071 Cedex 2, France
| | - Martine Cadene
- Centre de Biophysique Moléculaire, UPR4301, CNRS, affiliated to Université d'Orléans, Rue Charles Sadron, Orléans45071 Cedex 2, France
| |
Collapse
|
15
|
Sarin D, Kumar S, Rathore AS. Multiattribute Monitoring of Charge-Based Heterogeneity of Recombinant Monoclonal Antibodies Using 2D HIC-WCX-MS. Anal Chem 2022; 94:15018-15026. [PMID: 36260865 DOI: 10.1021/acs.analchem.2c02931] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/28/2022]
Abstract
Charged heterogeneity of monoclonal antibody (mAb) products is regarded as a critical quality attribute (CQA) depending on its impact on the safety and efficacy profile of the product. Hence, manufacturers are expected to perform a comprehensive characterization of the charge heterogeneity to ensure that the manufactured product meets its specifications. Further, monitoring is also expected during the product lifecycle to demonstrate consistency in product quality. However, conventional analytical methods for characterization of hydrophobic and charge variants are nonvolatile salt-based and require manual fraction collection and desalting steps before analysis through mass spectrometry can be performed. In the present study, a workflow of a two-dimensional liquid chromatography method using mass spectrometry (MS)-compatible buffers coupled with native mass spectrometry was performed to characterize hydrophobic variants in the first dimension and charge variants in the second dimension without any need for manual fractionation. This novel two-dimensional (2D) hydrophobic interaction chromatography (HIC)-weak cation-exchange chromatography (WCX)-MS workflow identified 10 variants in mAb A, out of which 2 variants are exclusive to the 2D orthogonal method. Similarly, for mAb B, a total of 11 variants are identified, including 5 variants exclusive to the 2D orthogonal workflow. When compared to stand-alone, HIC resolved only 4 variants for both mAbs and WCX resolved 7 variants for mAb A and 6 variants for mAb B. In addition, the proposed method allows direct characterization of hydrophobic/charge variant peaks through native mass spectrometry in a single-run workflow.
Collapse
Affiliation(s)
- Deepika Sarin
- Department of Chemical Engineering, IIT Delhi, Hauz Khas, New Delhi, Delhi 110016, India
| | - Sunil Kumar
- Department of Chemical Engineering, IIT Delhi, Hauz Khas, New Delhi, Delhi 110016, India
| | - Anurag S Rathore
- Department of Chemical Engineering, IIT Delhi, Hauz Khas, New Delhi, Delhi 110016, India
| |
Collapse
|
16
|
Li J, Zhang J, Xu M, Yang Z, Yue S, Zhou W, Gui C, Zhang H, Li S, Wang PG, Yang S. Advances in glycopeptide enrichment methods for the analysis of protein glycosylation over the past decade. J Sep Sci 2022; 45:3169-3186. [PMID: 35816156 DOI: 10.1002/jssc.202200292] [Citation(s) in RCA: 21] [Impact Index Per Article: 7.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/09/2022] [Revised: 06/16/2022] [Accepted: 07/01/2022] [Indexed: 11/12/2022]
Abstract
Advances in bioanalytical technology have accelerated the analysis of complex protein glycosylation, which is beneficial to understanding glycosylation in drug discovery and disease diagnosis. Due to its biological uniqueness in the course of disease occurrence and development, disease-specific glycosylation requires quantitative characterization of protein glycosylation. We provide a comprehensive review of recent advances in glycosylation analysis, including workflows for glycoprotein digestion, glycopeptide separation and enrichment, and mass-spectrometry sequencing. We specifically focus on different strategies for glycopeptide enrichment through physical interaction, chemical oxidation, or metabolic labeling of intact glycopeptides. The recent advances and challenges of O-glycosylation analysis are presented, and the development of improved enrichment methods combining different proteases to analyze O-glycosylation is also proposed. This article is protected by copyright. All rights reserved.
Collapse
Affiliation(s)
- Jiajia Li
- Center for Clinical Mass Spectrometry, College of Pharmaceutical Sciences, Soochow University, Jiangsu, 215123, China
| | - Jie Zhang
- Center for Clinical Mass Spectrometry, College of Pharmaceutical Sciences, Soochow University, Jiangsu, 215123, China
| | - Mingming Xu
- Center for Clinical Mass Spectrometry, College of Pharmaceutical Sciences, Soochow University, Jiangsu, 215123, China
| | - Zeren Yang
- AstraZeneca, Medimmune Ct, Frederick, MD, 21703, USA
| | - Shuang Yue
- Center for Clinical Mass Spectrometry, College of Pharmaceutical Sciences, Soochow University, Jiangsu, 215123, China
| | - Wanlong Zhou
- U.S. Food and Drug Administration, Forensic Chemistry Center, Cincinnati, OH, 45237, USA
| | - Chunshan Gui
- Department of Pharmaceutical Analysis, College of Pharmaceutical Sciences, Soochow University, Jiangsu, 215123, China
| | - Haiyang Zhang
- Department of Pharmaceutical Analysis, College of Pharmaceutical Sciences, Soochow University, Jiangsu, 215123, China
| | - Shuwei Li
- Nanjing Apollomics Biotech, Inc., Nanjing, Jiangsu, 210033, China
| | - Perry G Wang
- U.S. Food and Drug Administration, Center for Food Safety and Applied Nutrition, College Park, MD, 20740, USA
| | - Shuang Yang
- Center for Clinical Mass Spectrometry, College of Pharmaceutical Sciences, Soochow University, Jiangsu, 215123, China.,Department of Pharmaceutical Analysis, College of Pharmaceutical Sciences, Soochow University, Jiangsu, 215123, China
| |
Collapse
|
17
|
2021 White Paper on Recent Issues in Bioanalysis: Mass Spec of Proteins, Extracellular Vesicles, CRISPR, Chiral Assays, Oligos; Nanomedicines Bioanalysis; ICH M10 Section 7.1; Non-Liquid & Rare Matrices; Regulatory Inputs ( Part 1A - Recommendations on Endogenous Compounds, Small Molecules, Complex Methods, Regulated Mass Spec of Large Molecules, Small Molecule, PoC & Part 1B - Regulatory Agencies' Inputs on Bioanalysis, Biomarkers, Immunogenicity, Gene & Cell Therapy and Vaccine). Bioanalysis 2022; 14:505-580. [PMID: 35578993 DOI: 10.4155/bio-2022-0078] [Citation(s) in RCA: 17] [Impact Index Per Article: 5.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/13/2023] Open
Abstract
The 15th edition of the Workshop on Recent Issues in Bioanalysis (15th WRIB) was held on 27 September to 1 October 2021. Even with a last-minute move from in-person to virtual, an overwhelmingly high number of nearly 900 professionals representing pharma and biotech companies, contract research organizations (CROs), and multiple regulatory agencies still eagerly convened to actively discuss the most current topics of interest in bioanalysis. The 15th WRIB included 3 Main Workshops and 7 Specialized Workshops that together spanned 1 week in order to allow exhaustive and thorough coverage of all major issues in bioanalysis, biomarkers, immunogenicity, gene therapy, cell therapy and vaccines. Moreover, in-depth workshops on biomarker assay development and validation (BAV) (focused on clarifying the confusion created by the increased use of the term "Context of Use - COU"); mass spectrometry of proteins (therapeutic, biomarker and transgene); state-of-the-art cytometry innovation and validation; and, critical reagent and positive control generation were the special features of the 15th edition. This 2021 White Paper encompasses recommendations emerging from the extensive discussions held during the workshop, and is aimed to provide the bioanalytical community with key information and practical solutions on topics and issues addressed, in an effort to enable advances in scientific excellence, improved quality and better regulatory compliance. Due to its length, the 2021 edition of this comprehensive White Paper has been divided into three parts for editorial reasons. This publication (Part 1A) covers the recommendations on Endogenous Compounds, Small Molecules, Complex Methods, Regulated Mass Spec of Large Molecules, Small Molecule, PoC. Part 1B covers the Regulatory Agencies' Inputs on Bioanalysis, Biomarkers, Immunogenicity, Gene & Cell Therapy and Vaccine. Part 2 (ISR for Biomarkers, Liquid Biopsies, Spectral Cytometry, Inhalation/Oral & Multispecific Biotherapeutics, Accuracy/LLOQ for Flow Cytometry) and Part 3 (TAb/NAb, Viral Vector CDx, Shedding Assays; CRISPR/Cas9 & CAR-T Immunogenicity; PCR & Vaccine Assay Performance; ADA Assay Comparabil ity & Cut Point Appropriateness) are published in volume 14 of Bioanalysis, issues 10 and 11 (2022), respectively.
Collapse
|
18
|
Abstract
Native mass spectrometry (MS) is aimed at preserving and determining the native structure, composition, and stoichiometry of biomolecules and their complexes from solution after they are transferred into the gas phase. Major improvements in native MS instrumentation and experimental methods over the past few decades have led to a concomitant increase in the complexity and heterogeneity of samples that can be analyzed, including protein-ligand complexes, protein complexes with multiple coexisting stoichiometries, and membrane protein-lipid assemblies. Heterogeneous features of these biomolecular samples can be important for understanding structure and function. However, sample heterogeneity can make assignment of ion mass, charge, composition, and structure very challenging due to the overlap of tens or even hundreds of peaks in the mass spectrum. In this review, we cover data analysis, experimental, and instrumental advances and strategies aimed at solving this problem, with an in-depth discussion of theoretical and practical aspects of the use of available deconvolution algorithms and tools. We also reflect upon current challenges and provide a view of the future of this exciting field.
Collapse
Affiliation(s)
- Amber D. Rolland
- Department of Chemistry and Biochemistry, 1253 University of Oregon, Eugene, OR, USA 97403-1253
| | - James S. Prell
- Department of Chemistry and Biochemistry, 1253 University of Oregon, Eugene, OR, USA 97403-1253
- Materials Science Institute, 1252 University of Oregon, Eugene, OR, USA 97403-1252
| |
Collapse
|
19
|
Xu T, Han L, George Thompson AM, Sun L. An improved capillary isoelectric focusing-mass spectrometry method for high-resolution characterization of monoclonal antibody charge variants. ANALYTICAL METHODS : ADVANCING METHODS AND APPLICATIONS 2022; 14:383-393. [PMID: 34939625 DOI: 10.1039/d1ay01556g] [Citation(s) in RCA: 17] [Impact Index Per Article: 5.7] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/14/2023]
Abstract
Routine and high-resolution characterization of monoclonal antibody (mAb) charge variants is vital for controlling mAb quality as therapeutics. Capillary isoelectric focusing-mass spectrometry (cIEF-MS) has emerged as a powerful tool for characterizing mAb charge variants because it can achieve high-resolution separation and highly sensitive detection of proteins. It provides much better identification of charge variants than the traditionally used cIEF-UV method. However, further improvement of cIEF-MS regarding stability and separation resolution is needed. Here, we improved the stability and enhanced separation resolution of automated cIEF-MS by bettering the quality of capillary neutral coating, reducing catholyte pH to 10 for cIEF-MS for the first time, and systematically optimizing the cIEF separation conditions. The improved cIEF-MS method was applied to characterize charge variants of three previously well characterized mAbs (NISTmAb, cetuximab, trastuzumab) and one tool mAb (mAb1). The charge variants of the studied mAbs were well resolved, and the majority of post-translational modifications (PTMs) found in those mAbs agreed with the literature. cIEF-MS analyses of mAb1 were capable of discovering ten charge variants with various interesting PTMs, such as PGK amidation, incomplete C-terminal lysine clipping, glycosylation, and deamination. cIEF-MS was successfully used for accurately determining the isoelectric points (pIs) of mAb1 charge variants via analyzing the pI markers and spiking in a standard protein (cytochrome c) to samples for migration time normalization, which is beneficial for evaluating pI-related pharmacokinetic properties. Our cIEF-MS agreed with and, in some cases (i.e., cetuximab and mAb1), outperformed cIEF-UV for detecting mAb charge variants.
Collapse
Affiliation(s)
- Tian Xu
- Department of Chemistry, Michigan State University, 578 S Shaw Lane, East Lansing, MI 48824, USA.
| | - Linjie Han
- New Biological Entities (NBE), Analytical R&D, AbbVie Inc., 1 Waukegan Rd, North Chicago, IL, 60064, USA
| | - Alayna M George Thompson
- New Biological Entities (NBE), Analytical R&D, AbbVie Inc., 1 Waukegan Rd, North Chicago, IL, 60064, USA
| | - Liangliang Sun
- Department of Chemistry, Michigan State University, 578 S Shaw Lane, East Lansing, MI 48824, USA.
| |
Collapse
|
20
|
Naumann L, Schlossbauer P, Klingler F, Hesse F, Otte K, Neusüß C. High throughput glycosylation analysis of intact monoclonal antibodies by mass spectrometry coupled with capillary electrophoresis and liquid chromatography. J Sep Sci 2022; 45:2034-2044. [PMID: 35044720 DOI: 10.1002/jssc.202100865] [Citation(s) in RCA: 11] [Impact Index Per Article: 3.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/27/2021] [Revised: 01/05/2022] [Accepted: 01/08/2022] [Indexed: 11/07/2022]
Abstract
The analysis of monoclonal antibodies glycosylation is a crucial quality control attribute of biopharmaceutical drugs. High throughput screening approaches for antibody glycoform analysis are required in various stages of process optimization. Here, we present high throughput screening suitable mass spectrometry-based workflows for the analysis of intact antibody glycosylation out of cell supernatants. Capillary electrophoresis and liquid chromatography were coupled with quadrupole time-of-flight MS or Orbitrap MS. Both separation methods offer fast separation (10-15 min) and the capability to prevent the separated cell supernatant matrix to enter the MS by post-separation valving. Both MS instruments provide comparable results and both are sufficient to determine the glycosylation pattern of the five major glycoforms of the measured antibodies. However, the Orbitrap yields higher sensitivity of 25 μg/mL (CE-nanoCEasy-Orbitrap MS) and 5 μg/mL (LC-Orbitrap MS). Data processing was optimized for a faster processing and easier detection of low abundant glycoforms based on averaged charge-deconvoluted mass spectra. This approach combines a non-target glycoform analysis, while yielding the same glycosylation pattern as the traditional approach based on extracted ion traces. The presented methods enable the high throughput screening of the glycosylation pattern of antibodies down to low μg/mL-range out of cell supernatant without any sample preparation. This article is protected by copyright. All rights reserved.
Collapse
Affiliation(s)
- Lukas Naumann
- Department of Chemistry, Aalen University, Beethovenstraße 1, Aalen, 73430, Germany
| | - Patrick Schlossbauer
- Department of applied Biotechnology, Biberach University of Applied Sciences, Karlstraße 6-11, Biberach, 88400, Germany
| | - Florian Klingler
- Department of applied Biotechnology, Biberach University of Applied Sciences, Karlstraße 6-11, Biberach, 88400, Germany
| | - Friedemann Hesse
- Department of applied Biotechnology, Biberach University of Applied Sciences, Karlstraße 6-11, Biberach, 88400, Germany
| | - Kerstin Otte
- Department of applied Biotechnology, Biberach University of Applied Sciences, Karlstraße 6-11, Biberach, 88400, Germany
| | - Christian Neusüß
- Department of Chemistry, Aalen University, Beethovenstraße 1, Aalen, 73430, Germany
| |
Collapse
|