Sturgill B, Hernandez-Reynoso AG, Druschel LN, Smith TJ, Boucher PE, Hoeferlin GF, Thai TTD, Jiang MS, Hess JL, Alam NN, Menendez DM, Duncan JL, Cogan SF, Pancrazio JJ, Capadona JR. Reactive Amine Functionalized Microelectrode Arrays Provide Short-Term Benefit but Long-Term Detriment to In Vivo Recording Performance. ACS APPLIED BIO MATERIALS 2024; 7:1052-1063. [PMID: 38290529 PMCID: PMC10880090 DOI: 10.1021/acsabm.3c01014] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/28/2023] [Revised: 01/08/2024] [Accepted: 01/10/2024] [Indexed: 02/01/2024]
Abstract
Intracortical microelectrode arrays (MEAs) are used for recording neural signals. However, indwelling devices result in chronic neuroinflammation, which leads to decreased recording performance through degradation of the device and surrounding tissue. Coating the MEAs with bioactive molecules is being explored to mitigate neuroinflammation. Such approaches often require an intermediate functionalization step such as (3-aminopropyl)triethoxysilane (APTES), which serves as a linker. However, the standalone effect of this intermediate step has not been previously characterized. Here, we investigated the effect of coating MEAs with APTES by comparing APTES-coated to uncoated controls in vivo and ex vivo. First, we measured water contact angles between silicon uncoated and APTES-coated substrates to verify the hydrophilic characteristics of the APTES coating. Next, we implanted MEAs in the motor cortex (M1) of Sprague-Dawley rats with uncoated or APTES-coated devices. We assessed changes in the electrochemical impedance and neural recording performance over a chronic implantation period of 16 weeks. Additionally, histology and bulk gene expression were analyzed to understand further the reactive tissue changes arising from the coating. Results showed that APTES increased the hydrophilicity of the devices and decreased electrochemical impedance at 1 kHz. APTES coatings proved detrimental to the recording performance, as shown by a constant decay up to 16 weeks postimplantation. Bulk gene analysis showed differential changes in gene expression between groups that were inconclusive with regard to the long-term effect on neuronal tissue. Together, these results suggest that APTES coatings are ultimately detrimental to chronic neural recordings. Furthermore, interpretations of studies using APTES as a functionalization step should consider the potential consequences if the final functionalization step is incomplete.
Collapse
Affiliation(s)
- Brandon
S. Sturgill
- Department
of Bioengineering, The University of Texas
at Dallas, 800 W. Campbell Road, Richardson, Texas 75080, United States
| | - Ana G. Hernandez-Reynoso
- Department
of Bioengineering, The University of Texas
at Dallas, 800 W. Campbell Road, Richardson, Texas 75080, United States
| | - Lindsey N. Druschel
- Department
of Biomedical Engineering, Case Western
Reserve University. 10900 Euclid Ave, Cleveland, Ohio 44106, United States
- Advanced
Platform Technology Center, Louis Stokes Cleveland Veterans Affairs
Medical Center, Cleveland, Ohio 44106, United States
| | - Thomas J. Smith
- School
of Behavioral and BrainSciences, The University
of Texas at Dallas, 800 W. Campbell Road, Richardson, Texas 75080, United States
| | - Pierce E. Boucher
- Department
of Biomedical Engineering, Case Western
Reserve University. 10900 Euclid Ave, Cleveland, Ohio 44106, United States
- Advanced
Platform Technology Center, Louis Stokes Cleveland Veterans Affairs
Medical Center, Cleveland, Ohio 44106, United States
| | - George F. Hoeferlin
- Department
of Biomedical Engineering, Case Western
Reserve University. 10900 Euclid Ave, Cleveland, Ohio 44106, United States
- Advanced
Platform Technology Center, Louis Stokes Cleveland Veterans Affairs
Medical Center, Cleveland, Ohio 44106, United States
| | - Teresa Thuc Doan Thai
- Department
of Bioengineering, The University of Texas
at Dallas, 800 W. Campbell Road, Richardson, Texas 75080, United States
| | - Madison S. Jiang
- School
of Behavioral and BrainSciences, The University
of Texas at Dallas, 800 W. Campbell Road, Richardson, Texas 75080, United States
| | - Jordan L. Hess
- School
of Behavioral and BrainSciences, The University
of Texas at Dallas, 800 W. Campbell Road, Richardson, Texas 75080, United States
| | - Neeha N. Alam
- Department
of Bioengineering, The University of Texas
at Dallas, 800 W. Campbell Road, Richardson, Texas 75080, United States
| | - Dhariyat M. Menendez
- Department
of Biomedical Engineering, Case Western
Reserve University. 10900 Euclid Ave, Cleveland, Ohio 44106, United States
- Advanced
Platform Technology Center, Louis Stokes Cleveland Veterans Affairs
Medical Center, Cleveland, Ohio 44106, United States
| | - Jonathan L. Duncan
- Department
of Biomedical Engineering, Case Western
Reserve University. 10900 Euclid Ave, Cleveland, Ohio 44106, United States
- Advanced
Platform Technology Center, Louis Stokes Cleveland Veterans Affairs
Medical Center, Cleveland, Ohio 44106, United States
| | - Stuart F. Cogan
- Department
of Bioengineering, The University of Texas
at Dallas, 800 W. Campbell Road, Richardson, Texas 75080, United States
| | - Joseph J. Pancrazio
- Department
of Bioengineering, The University of Texas
at Dallas, 800 W. Campbell Road, Richardson, Texas 75080, United States
| | - Jeffrey R. Capadona
- Department
of Biomedical Engineering, Case Western
Reserve University. 10900 Euclid Ave, Cleveland, Ohio 44106, United States
- Advanced
Platform Technology Center, Louis Stokes Cleveland Veterans Affairs
Medical Center, Cleveland, Ohio 44106, United States
| |
Collapse
|
2
|
Singh M, Teodorescu DL, Rowlett M, Wang SX, Balcells M, Park C, Bernardo B, McGarel S, Reeves C, Mehra MR, Zhao X, Yuk H, Roche ET. A Tunable Soft Silicone Bioadhesive for Secure Anchoring of Diverse Medical Devices to Wet Biological Tissue. ADVANCED MATERIALS (DEERFIELD BEACH, FLA.) 2024; 36:e2307288. [PMID: 37865838 DOI: 10.1002/adma.202307288] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 07/23/2023] [Revised: 09/21/2023] [Indexed: 10/23/2023]
Abstract
Silicone is utilized widely in medical devices for its compatibility with tissues and bodily fluids, making it a versatile material for implants and wearables. To effectively bond silicone devices to biological tissues, a reliable adhesive is required to create a long-lasting interface. BioAdheSil, a silicone-based bioadhesive designed to provide robust adhesion on both sides of the interface is introduced here, facilitating bonding between dissimilar substrates, namely silicone devices and tissues. The adhesive's design focuses on two key aspects: wet tissue adhesion capability and tissue-infiltration-based long-term integration. BioAdheSil is formulated by mixing soft silicone oligomers with siloxane coupling agents and absorbents for bonding the hydrophobic silicone device to hydrophilic tissues. Incorporation of biodegradable absorbents eliminates surface water and controls porosity, while silane crosslinkers provide interfacial strength. Over time, BioAdheSil transitions from nonpermeable to permeable through enzyme degradation, creating a porous structure that facilitates cell migration and tissue integration, potentially enabling long-lasting adhesion. Experimental results demonstrate that BioAdheSil outperforms commercial adhesives and elicits no adverse response in rats. BioAdheSil offers practical utility for adhering silicone devices to wet tissues, including long-term implants and transcutaneous devices. Here, its functionality is demonstrated through applications such as tracheal stents and left ventricular assist device lines.
Collapse
Affiliation(s)
- Manisha Singh
- Institute for Medical Engineering and Science, Massachusetts Institute of Technology, Cambridge, MA, 02139, USA
| | - Debbie L Teodorescu
- Department of Cardiology, Cedars-Sinai Smidt Heart Institute, Los Angeles, CA, 90048, USA
| | - Meagan Rowlett
- Department of Biological Engineering, Massachusetts Institute of Technology, Cambridge, MA, 02139, USA
| | - Sophie X Wang
- Institute for Medical Engineering and Science, Massachusetts Institute of Technology, Cambridge, MA, 02139, USA
- Department of Surgery, Beth Israel Deaconess Medical Center, Boston, MA, 02215, USA
| | - Mercedes Balcells
- Institute for Medical Engineering and Science, Massachusetts Institute of Technology, Cambridge, MA, 02139, USA
- Bioengineering Department, Institut Químic de Sarrià, Ramon Llull Univ, Barcelona, Spain, 08017
| | - Clara Park
- Institute for Medical Engineering and Science, Massachusetts Institute of Technology, Cambridge, MA, 02139, USA
- Department of Mechanical Engineering, Massachusetts Institute of Technology, Cambridge, MA, 02139, USA
| | - Bruno Bernardo
- Institute for Medical Engineering and Science, Massachusetts Institute of Technology, Cambridge, MA, 02139, USA
| | - Sian McGarel
- Institute for Medical Engineering and Science, Massachusetts Institute of Technology, Cambridge, MA, 02139, USA
| | - Charlotte Reeves
- Institute for Medical Engineering and Science, Massachusetts Institute of Technology, Cambridge, MA, 02139, USA
| | - Mandeep R Mehra
- Brigham and Women's Hospital and Harvard Medical School, Boston, MA, 02115, USA
| | - Xuanhe Zhao
- Department of Mechanical Engineering, Massachusetts Institute of Technology, Cambridge, MA, 02139, USA
| | - Hyunwoo Yuk
- Department of Mechanical Engineering, Massachusetts Institute of Technology, Cambridge, MA, 02139, USA
- SanaHeal, Inc, Cambridge, MA, 02139, USA
| | - Ellen T Roche
- Institute for Medical Engineering and Science, Massachusetts Institute of Technology, Cambridge, MA, 02139, USA
- Department of Mechanical Engineering, Massachusetts Institute of Technology, Cambridge, MA, 02139, USA
| |
Collapse
|
3
|
Cho W, Yoon SH, Chung TD. Streamlining the interface between electronics and neural systems for bidirectional electrochemical communication. Chem Sci 2023; 14:4463-4479. [PMID: 37152246 PMCID: PMC10155913 DOI: 10.1039/d3sc00338h] [Citation(s) in RCA: 3] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/19/2023] [Accepted: 04/13/2023] [Indexed: 05/09/2023] Open
Abstract
Seamless neural interfaces conjoining neurons and electrochemical devices hold great potential for highly efficient signal transmission across neural systems and the external world. Signal transmission through chemical sensing and stimulation via electrochemistry is remarkable because communication occurs through the same chemical language of neurons. Emerging strategies based on synaptic interfaces, iontronics-based neuromodulation, and improvements in selective neurosensing techniques have been explored to achieve seamless integration and efficient neuro-electronics communication. Synaptic interfaces can directly exchange signals to and from neurons, in a similar manner to that of chemical synapses. Hydrogel-based iontronic chemical delivery devices are operationally compatible with neural systems for improved neuromodulation. In this perspective, we explore developments to improve the interface between neurons and electrodes by targeting neurons or sub-neuronal regions including synapses. Furthermore, recent progress in electrochemical neurosensing and iontronics-based chemical delivery is examined.
Collapse
Affiliation(s)
- Wonkyung Cho
- Department of Chemistry, Seoul National University Seoul 08826 Republic of Korea
| | - Sun-Heui Yoon
- Department of Chemistry, Seoul National University Seoul 08826 Republic of Korea
| | - Taek Dong Chung
- Department of Chemistry, Seoul National University Seoul 08826 Republic of Korea
- Advanced Institutes of Convergence Technology Suwon-si 16229 Gyeonggi-do Republic of Korea
| |
Collapse
|
4
|
Wolf NR, Rai P, Glass M, Milos F, Maybeck V, Offenhäusser A, Wördenweber R. Mechanical and Electronic Cell-Chip Interaction of APTES-Functionalized Neuroelectronic Interfaces. ACS APPLIED BIO MATERIALS 2021; 4:6326-6337. [PMID: 35006867 DOI: 10.1021/acsabm.1c00576] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/28/2022]
Abstract
In this work, we analyze the impact of a chip coating with a self-assembled monolayer (SAM) of (3-aminopropyl)triethoxysilane (APTES) on the electronic and mechanical properties of neuroelectronic interfaces. We show that the large signal transfer, which has been observed for these interfaces, is most likely a consequence of the strong mechanical coupling between cells and substrate. On the one hand, we demonstrate that the impedance of the interface between Pt electrodes and an electrolyte is slightly reduced by the APTES SAM. However, this reduction of approximately 13% is definitely not sufficient to explain the large signal transfer of APTES coated electrodes demonstrated previously. On the other hand, the APTES coating leads to a stronger mechanical clamping of the cells, which is visible in microscopic images of the cell development of APTES-coated substrates. This stronger mechanical interaction is most likely caused by the positively charged amino functional group of the APTES SAM. It seems to lead to a smaller cleft between substrate and cells and, thus, to reduced losses of the cell's action potential signal at the electrode. The disadvantage of this tight binding of the cells to the rigid, planar substrate seems to be the short lifetime of the cells. In our case the density of living cells starts to decrease together with the visual deformation of the cells typically at DIV 9. Solutions for this problem might be the use of soft substrates and/or the replacement of the short APTES molecules with larger molecules or molecular multilayers.
Collapse
Affiliation(s)
- Nikolaus R Wolf
- Institute of Biological Information Processing - Bioelectronics (IBI-3), Forschungszentrum Jülich, 52425 Jülich, Germany
| | - Pratika Rai
- Institute of Biological Information Processing - Bioelectronics (IBI-3), Forschungszentrum Jülich, 52425 Jülich, Germany
| | - Manuel Glass
- Institute of Biological Information Processing - Bioelectronics (IBI-3), Forschungszentrum Jülich, 52425 Jülich, Germany
| | - Frano Milos
- Institute of Biological Information Processing - Bioelectronics (IBI-3), Forschungszentrum Jülich, 52425 Jülich, Germany
| | - Vanessa Maybeck
- Institute of Biological Information Processing - Bioelectronics (IBI-3), Forschungszentrum Jülich, 52425 Jülich, Germany
| | - Andreas Offenhäusser
- Institute of Biological Information Processing - Bioelectronics (IBI-3), Forschungszentrum Jülich, 52425 Jülich, Germany
| | - Roger Wördenweber
- Institute of Biological Information Processing - Bioelectronics (IBI-3), Forschungszentrum Jülich, 52425 Jülich, Germany
| |
Collapse
|