1
|
Di Lena D, Sisti E, Brass E, Belforte E, Marini B, Porchetta A, Squarcia L, Da Pozzo E, Bertucci A, Ippodrino R. Rapid, Single-Step Monitoring of Monoclonal Antibody Bioavailability by Using a TNF-α-Based Multiepitope DNA Nanoswitch. Anal Chem 2025; 97:8195-8201. [PMID: 40198205 PMCID: PMC12019779 DOI: 10.1021/acs.analchem.5c01239] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/27/2025] [Revised: 03/25/2025] [Accepted: 03/27/2025] [Indexed: 04/10/2025]
Abstract
Therapeutic drug monitoring (TDM) is increasingly valuable for tailoring personalized therapy, particularly in managing chronic inflammatory diseases where overtreatment can cause significant side effects. Monoclonal antibodies (mAbs), a primary therapeutic approach for these conditions, face challenges from antidrug antibodies (ADAs), which can reduce mAb bioavailability and efficacy. To address these issues, we utilized Tumor Necrosis Factor α (TNF-α) as a binding moiety in a fluorescence-based programmable nanosensor within the NanoHYBRID (NH) platform developed by Ulisse Biomed S.p.A. By directly conjugating TNF-α to DNA probes, we developed a rapid, homogeneous, affinity-based assay capable of detecting multiple mAbs targeting distinct epitopes on the same protein. This NH platform effectively detected therapeutic concentrations of clinically relevant mAbs, such as Infliximab, Adalimumab, and Golimumab, in blood serum samples in a one-step process, bypassing the need for time-intensive washing steps. Moreover, the NH sensor exhibited heightened sensitivity to the presence of ADA, which impacted drug quantification, indicating its utility for monitoring bioavailable mAb levels. Compared to ELISA, the NH platform demonstrated superior sensitivity to ADAs, suggesting its potential as a highly specific, modular solution for TDM. This modular design allows the NH platform to create multiepitope nanosensors capable of measuring bioavailable mAbs in a single step.
Collapse
Affiliation(s)
- Denise Di Lena
- Ulisse
BioMed Laboratories, Area Science Park, 34149 Trieste, Italy
- Department
of Chemistry, Life Sciences and Environmental Sustainability, University of Parma, Parco Area delle Scienze 17/a, 43124 Parma, Italy
| | - Edoardo Sisti
- Ulisse
BioMed Laboratories, Area Science Park, 34149 Trieste, Italy
- Department
of Pharmacy, University of Pisa, via Bonanno 6, 56126 Pisa, Italy
| | - Erik Brass
- Ulisse
BioMed Laboratories, Area Science Park, 34149 Trieste, Italy
| | - Erica Belforte
- Department
of Chemistry, University of Rome, Tor Vergata, Via della Ricerca Scientifica, 00133 Rome, Italy
| | - Bruna Marini
- Ulisse
BioMed Laboratories, Area Science Park, 34149 Trieste, Italy
| | - Alessandro Porchetta
- Department
of Chemistry, University of Rome, Tor Vergata, Via della Ricerca Scientifica, 00133 Rome, Italy
| | - Laura Squarcia
- Ulisse
BioMed Laboratories, Area Science Park, 34149 Trieste, Italy
| | - Eleonora Da Pozzo
- Department
of Pharmacy, University of Pisa, via Bonanno 6, 56126 Pisa, Italy
- CISUP, Center
for Instrumentation Sharing of the University
of Pisa, Lungarno Pacinotti
43/44, 56126 Pisa, Italy
| | - Alessandro Bertucci
- Department
of Chemistry, Life Sciences and Environmental Sustainability, University of Parma, Parco Area delle Scienze 17/a, 43124 Parma, Italy
| | - Rudy Ippodrino
- Ulisse
BioMed Laboratories, Area Science Park, 34149 Trieste, Italy
| |
Collapse
|
2
|
Wei X, Luo QY, Li Y, Yuan J, Deng M, Liu X, Zhong P, Ouyang H, Li Y, Huang J, Quan H, Chu J, Yu X, Zhou W, Jin Z. Flexible Site-Specific Labeling-Mediated Self-Assembly Sensor Based on Quantum Dots and LUMinescent AntiBody Sensor for Duplexed Detection of Antibodies. ACS Sens 2025; 10:301-309. [PMID: 39791864 DOI: 10.1021/acssensors.4c02509] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/12/2025]
Abstract
Over recent years, the LUMinescent AntiBody Sensor (LUMABS) system, utilizing bioluminescence resonance energy transfer (BRET), has emerged as a highly effective method for antibody detection. This system incorporates NanoLuc (Nluc) as the donor and fluorescent protein (FP) as the acceptor. However, the limited Stokes shift of FP poses a challenge, as it leads to significant spectral cross-talk between the excitation and emission spectra. This issue complicates the implementation of multiplexed detection. To address this challenge, we present an innovative enhancement to the LUMABS sensor with quantum dots (QDs) as the acceptor instead of FP. The use of QDs offers several advantages over those of traditional FP-based sensors. The biotin-avidin system facilitates the flexible interchangeability of QDs, allowing for a more convenient multicolor sensor construct. The new QD-LUMABS system overcomes the limitations of spectral cross-talk and provides better spectral separation. This breakthrough enables the successful implementation of multiplexed detection for multiple targets simultaneously. Results demonstrated that the wavelength-tunable QD-LUMABS sensors achieved picomolar-level detection limits for antibodies and that this sensor-construction strategy was generally applicable among various epitopes and their antibodies. Furthermore, this sensor displayed excellent duplexing capabilities. These features underscore its potential for future clinical disease diagnosis applications.
Collapse
Affiliation(s)
- Xiaoyuan Wei
- Materials Interfaces Center, Shenzhen Institutes of Advanced Technology, Chinese Academy of Sciences, Shenzhen 518055, P. R. China
- College of Chemistry, Huazhong Agricultural University, Wuhan 430070, P. R. China
| | - Qing-Ying Luo
- Materials Interfaces Center, Shenzhen Institutes of Advanced Technology, Chinese Academy of Sciences, Shenzhen 518055, P. R. China
- School of Food and Drug, Shenzhen Polytechnic University, Shenzhen 518055, P. R. China
| | - Yeqing Li
- Materials Interfaces Center, Shenzhen Institutes of Advanced Technology, Chinese Academy of Sciences, Shenzhen 518055, P. R. China
| | - Jing Yuan
- Shenzhen Bay Laboratory, Institute of Systems and Physical Biology, Shenzhen 518132, P. R. China
| | - Mengying Deng
- Guangdong Provincial Key Laboratory of Biomedical Optical Imaging Technology & Center for Biomedical Optics and Molecular Imaging & CAS Key Laboratory of Health Informatics, Shenzhen Institute of Advanced Technology, Chinese Academy of Sciences, Shenzhen 518055, P. R. China
| | - Xinyu Liu
- Materials Interfaces Center, Shenzhen Institutes of Advanced Technology, Chinese Academy of Sciences, Shenzhen 518055, P. R. China
| | - Peiluan Zhong
- Materials Interfaces Center, Shenzhen Institutes of Advanced Technology, Chinese Academy of Sciences, Shenzhen 518055, P. R. China
| | | | - Yanfei Li
- HeavyBio, Inc., Shenzhen 518102, P. R. China
| | | | | | - Jun Chu
- Guangdong Provincial Key Laboratory of Biomedical Optical Imaging Technology & Center for Biomedical Optics and Molecular Imaging & CAS Key Laboratory of Health Informatics, Shenzhen Institute of Advanced Technology, Chinese Academy of Sciences, Shenzhen 518055, P. R. China
| | - Xuefeng Yu
- Materials Interfaces Center, Shenzhen Institutes of Advanced Technology, Chinese Academy of Sciences, Shenzhen 518055, P. R. China
| | - Wenhua Zhou
- Materials Interfaces Center, Shenzhen Institutes of Advanced Technology, Chinese Academy of Sciences, Shenzhen 518055, P. R. China
| | - Zongwen Jin
- Materials Interfaces Center, Shenzhen Institutes of Advanced Technology, Chinese Academy of Sciences, Shenzhen 518055, P. R. China
| |
Collapse
|
3
|
Zhao S, Xiong Y, Sunnapu R, Zhang Y, Tian X, Ai HW. Bioluminescence Imaging of Potassium Ion Using a Sensory Luciferin and an Engineered Luciferase. J Am Chem Soc 2024; 146:13406-13416. [PMID: 38698549 PMCID: PMC11100015 DOI: 10.1021/jacs.4c02473] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/19/2024] [Revised: 04/22/2024] [Accepted: 04/23/2024] [Indexed: 05/05/2024]
Abstract
Bioluminescent indicators are power tools for studying dynamic biological processes. In this study, we present the generation of novel bioluminescent indicators by modifying the luciferin molecule with an analyte-binding moiety. Specifically, we have successfully developed the first bioluminescent indicator for potassium ions (K+), which are critical electrolytes in biological systems. Our approach involved the design and synthesis of a K+-binding luciferin named potassiorin. Additionally, we engineered a luciferase enzyme called BRIPO (bioluminescent red indicator for potassium) to work synergistically with potassiorin, resulting in optimized K+-dependent bioluminescence responses. Through extensive validation in cell lines, primary neurons, and live mice, we demonstrated the efficacy of this new tool for detecting K+. Our research demonstrates an innovative concept of incorporating sensory moieties into luciferins to modulate luciferase activity. This approach has great potential for developing a wide range of bioluminescent indicators, advancing bioluminescence imaging (BLI), and enabling the study of various analytes in biological systems.
Collapse
Affiliation(s)
- Shengyu Zhao
- Department
of Molecular Physiology and Biological Physics, University of Virginia School of Medicine, Charlottesville, Virginia 22908, United States
- Center
for Membrane and Cell Physiology, University
of Virginia School of Medicine, Charlottesville, Virginia 22908, United States
- Department
of Chemistry, University of Virginia, Charlottesville, Virginia 22904, United States
| | - Ying Xiong
- Department
of Molecular Physiology and Biological Physics, University of Virginia School of Medicine, Charlottesville, Virginia 22908, United States
- Center
for Membrane and Cell Physiology, University
of Virginia School of Medicine, Charlottesville, Virginia 22908, United States
| | - Ranganayakulu Sunnapu
- Department
of Molecular Physiology and Biological Physics, University of Virginia School of Medicine, Charlottesville, Virginia 22908, United States
- Center
for Membrane and Cell Physiology, University
of Virginia School of Medicine, Charlottesville, Virginia 22908, United States
| | - Yiyu Zhang
- Department
of Molecular Physiology and Biological Physics, University of Virginia School of Medicine, Charlottesville, Virginia 22908, United States
- Center
for Membrane and Cell Physiology, University
of Virginia School of Medicine, Charlottesville, Virginia 22908, United States
| | - Xiaodong Tian
- Department
of Molecular Physiology and Biological Physics, University of Virginia School of Medicine, Charlottesville, Virginia 22908, United States
- Center
for Membrane and Cell Physiology, University
of Virginia School of Medicine, Charlottesville, Virginia 22908, United States
| | - Hui-wang Ai
- Department
of Molecular Physiology and Biological Physics, University of Virginia School of Medicine, Charlottesville, Virginia 22908, United States
- Center
for Membrane and Cell Physiology, University
of Virginia School of Medicine, Charlottesville, Virginia 22908, United States
- Department
of Chemistry, University of Virginia, Charlottesville, Virginia 22904, United States
- The
UVA Comprehensive Cancer Center, University
of Virginia, Charlottesville, Virginia 22908, United States
| |
Collapse
|
4
|
van Aalen EA, Lurvink JJJ, Vermeulen L, van Gerven B, Ni Y, Arts R, Merkx M. Turning Antibodies into Ratiometric Bioluminescent Sensors for Competition-Based Homogeneous Immunoassays. ACS Sens 2024; 9:1401-1409. [PMID: 38380622 PMCID: PMC10964239 DOI: 10.1021/acssensors.3c02478] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/20/2023] [Revised: 02/02/2024] [Accepted: 02/08/2024] [Indexed: 02/22/2024]
Abstract
Here we present LUCOS (Luminescent Competition Sensor), a modular and broadly applicable bioluminescent diagnostic platform enabling the detection of both small molecules and protein biomarkers. The construction of LUCOS sensors entails the covalent and site-specific coupling of a bioluminescent sensor component to an analyte-specific antibody via protein G-mediated photoconjugation. Target detection is accomplished through intramolecular competition with a tethered analyte competitor for antibody binding. We established two variants of LUCOS: an inherent ratiometric LUCOSR variant and an intensiometric LUCOSI version, which can be used for ratiometric detection upon the addition of a split calibrator luciferase. To demonstrate the versatility of the LUCOS platform, sensors were developed for the detection of the small molecule cortisol and the protein biomarker NT-proBNP. Sensors for both targets displayed analyte-dependent changes in the emission ratio and enabled detection in the micromolar concentration range (KD,app = 16-92 μM). Furthermore, we showed that the response range of the LUCOS sensor can be adjusted by attenuating the affinity of the tethered NT-proBNP competitor, which enabled detection in the nanomolar concentration range (KD,app = 317 ± 26 nM). Overall, the LUCOS platform offers a highly versatile and easy method to convert commercially available monoclonal antibodies into bioluminescent biosensors that provide a homogeneous alternative for the competitive immunoassay.
Collapse
Affiliation(s)
- Eva A. van Aalen
- Laboratory
of Chemical Biology, Department of Biomedical Engineering, Eindhoven University of Technology, P.O. Box 513, Eindhoven 5600 MB, The
Netherlands
- Institute
for Complex Molecular Systems, Eindhoven
University of Technology, P.O. Box 513, Eindhoven 5600 MB, The Netherlands
| | - Joep J. J. Lurvink
- Laboratory
of Chemical Biology, Department of Biomedical Engineering, Eindhoven University of Technology, P.O. Box 513, Eindhoven 5600 MB, The
Netherlands
- Institute
for Complex Molecular Systems, Eindhoven
University of Technology, P.O. Box 513, Eindhoven 5600 MB, The Netherlands
| | - Leandra Vermeulen
- Laboratory
of Chemical Biology, Department of Biomedical Engineering, Eindhoven University of Technology, P.O. Box 513, Eindhoven 5600 MB, The
Netherlands
- Institute
for Complex Molecular Systems, Eindhoven
University of Technology, P.O. Box 513, Eindhoven 5600 MB, The Netherlands
| | - Benice van Gerven
- Laboratory
of Chemical Biology, Department of Biomedical Engineering, Eindhoven University of Technology, P.O. Box 513, Eindhoven 5600 MB, The
Netherlands
- Institute
for Complex Molecular Systems, Eindhoven
University of Technology, P.O. Box 513, Eindhoven 5600 MB, The Netherlands
| | - Yan Ni
- Laboratory
of Chemical Biology, Department of Biomedical Engineering, Eindhoven University of Technology, P.O. Box 513, Eindhoven 5600 MB, The
Netherlands
- Institute
for Complex Molecular Systems, Eindhoven
University of Technology, P.O. Box 513, Eindhoven 5600 MB, The Netherlands
| | - Remco Arts
- Laboratory
of Chemical Biology, Department of Biomedical Engineering, Eindhoven University of Technology, P.O. Box 513, Eindhoven 5600 MB, The
Netherlands
- Institute
for Complex Molecular Systems, Eindhoven
University of Technology, P.O. Box 513, Eindhoven 5600 MB, The Netherlands
| | - Maarten Merkx
- Laboratory
of Chemical Biology, Department of Biomedical Engineering, Eindhoven University of Technology, P.O. Box 513, Eindhoven 5600 MB, The
Netherlands
- Institute
for Complex Molecular Systems, Eindhoven
University of Technology, P.O. Box 513, Eindhoven 5600 MB, The Netherlands
| |
Collapse
|
5
|
Zhao S, Xiong Y, Sunnapu R, Zhang Y, Tian X, Ai HW. Bioluminescence Imaging of Potassium Ion Using a Sensory Luciferin and an Engineered Luciferase. BIORXIV : THE PREPRINT SERVER FOR BIOLOGY 2024:2024.03.13.581057. [PMID: 38559024 PMCID: PMC10980066 DOI: 10.1101/2024.03.13.581057] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 04/04/2024]
Abstract
Bioluminescent indicators are power tools for studying dynamic biological processes. In this study, we present the generation of novel bioluminescent indicators by modifying the luciferin molecule with an analyte-binding moiety. Specifically, we have successfully developed the first bioluminescent indicator for potassium ions (K+), which are critical electrolytes in biological systems. Our approach involved the design and synthesis of a K+-binding luciferin named potassiorin. Additionally, we engineered a luciferase enzyme called BRIPO (bioluminescent red indicator for potassium) to work synergistically with potassiorin, resulting in optimized K+-dependent bioluminescence responses. Through extensive validation in cell lines, primary neurons, and live mice, we demonstrated the efficacy of this new tool for detecting K+. Our research demonstrates an innovative concept of incorporating sensory moieties into luciferins to modulate luciferase activity. This approach has great potential for developing a wide range of bioluminescent indicators, advancing bioluminescence imaging (BLI), and enabling the study of various analytes in biological systems.
Collapse
Affiliation(s)
- Shengyu Zhao
- Department of Molecular Physiology and Biological Physics, University of Virginia School of Medicine, Charlottesville, Virginia 22908, USA
- Center for Membrane and Cell Physiology, University of Virginia School of Medicine, Charlottesville, Virginia 22908, USA
- Department of Chemistry, University of Virginia, Charlottesville, Virginia 22904, USA
| | - Ying Xiong
- Department of Molecular Physiology and Biological Physics, University of Virginia School of Medicine, Charlottesville, Virginia 22908, USA
- Center for Membrane and Cell Physiology, University of Virginia School of Medicine, Charlottesville, Virginia 22908, USA
| | - Ranganayakulu Sunnapu
- Department of Molecular Physiology and Biological Physics, University of Virginia School of Medicine, Charlottesville, Virginia 22908, USA
- Center for Membrane and Cell Physiology, University of Virginia School of Medicine, Charlottesville, Virginia 22908, USA
| | - Yiyu Zhang
- Department of Molecular Physiology and Biological Physics, University of Virginia School of Medicine, Charlottesville, Virginia 22908, USA
- Center for Membrane and Cell Physiology, University of Virginia School of Medicine, Charlottesville, Virginia 22908, USA
| | - Xiaodong Tian
- Department of Molecular Physiology and Biological Physics, University of Virginia School of Medicine, Charlottesville, Virginia 22908, USA
- Center for Membrane and Cell Physiology, University of Virginia School of Medicine, Charlottesville, Virginia 22908, USA
| | - Hui-Wang Ai
- Department of Molecular Physiology and Biological Physics, University of Virginia School of Medicine, Charlottesville, Virginia 22908, USA
- Center for Membrane and Cell Physiology, University of Virginia School of Medicine, Charlottesville, Virginia 22908, USA
- Department of Chemistry, University of Virginia, Charlottesville, Virginia 22904, USA
- The UVA Comprehensive Cancer Center, University of Virginia, Charlottesville, Virginia 22908, USA
| |
Collapse
|
6
|
Zhao Y, Yu X, Liu X, Zhang D, Li H, Zhou H, Kong W, Qu F. ClO - Induced Dual-Excitation Fluorescent Probes Responding to Diverse Testing Modes with Ratio Methodology. Anal Chem 2023; 95:7170-7177. [PMID: 37114482 DOI: 10.1021/acs.analchem.2c05532] [Citation(s) in RCA: 4] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 04/29/2023]
Abstract
Single-excitation ratio fluorescent probes have enabled the output signal with high signal-to-noise ratio, but are still plagued with technique challenges, including signal distortion and limited application scenario. Herein, a dual-excitation near-infrared (NIR) fluorescent probe P1 of coumarin derivatives is constructed, showing high signal output ability in the visible region and high tissue penetration depth ability in the NIR region. As NIR probe P1 selectively recognizes ClO-, the emission signal in the visible region (480 nm) of P1 is enhanced during the recognition process. Meanwhile, the NIR emission (830 nm) of the conjugated system is weakened, finally realizing that ClO- triggered the dual-excitation (720/400 nm) ratio fluorescence signal detection and monitoring. The signal of detection in vitro has high responsiveness. Meanwhile, in the process of NIR monitoring in vivo, positive contrast imaging of fluorescence is constructed, which can accurately monitor ClO- changes over time. The current dual-excitation fluorescence-based data calibration and/or comparison method improves the application of the traditional single-excitation ratio fluorescence strategy and provide innovative detection tools for accurate measurement of fluorescence detection, with detection/monitoring modes suitable for different physiological environments.
Collapse
Affiliation(s)
- Yan Zhao
- College of Chemistry and Chemical Engineering, Qufu Normal University, Qufu, Shandong 273165, China
| | - Xinquan Yu
- Department of Pathology, Cancer Hospital of Zhejiang Province, Hangzhou Institute of Medicine, Chinese Academy of Sciences, Hangzhou, Zhejiang 310022, China
| | - Xiao Liu
- College of Chemistry and Chemical Engineering, Qufu Normal University, Qufu, Shandong 273165, China
- Department of Pathology, Cancer Hospital of Zhejiang Province, Hangzhou Institute of Medicine, Chinese Academy of Sciences, Hangzhou, Zhejiang 310022, China
| | - Dailiang Zhang
- Department of Pathology, Cancer Hospital of Zhejiang Province, Hangzhou Institute of Medicine, Chinese Academy of Sciences, Hangzhou, Zhejiang 310022, China
| | - He Li
- College of Chemistry and Chemical Engineering, Qufu Normal University, Qufu, Shandong 273165, China
| | - Hanlin Zhou
- College of Chemistry and Chemical Engineering, Qufu Normal University, Qufu, Shandong 273165, China
| | - Weiheng Kong
- College of Chemistry and Chemical Engineering, Qufu Normal University, Qufu, Shandong 273165, China
| | - Fengli Qu
- College of Chemistry and Chemical Engineering, Qufu Normal University, Qufu, Shandong 273165, China
- Department of Pathology, Cancer Hospital of Zhejiang Province, Hangzhou Institute of Medicine, Chinese Academy of Sciences, Hangzhou, Zhejiang 310022, China
| |
Collapse
|
7
|
Torio EA, Ressler VT, Kincaid VA, Hurst R, Hall MP, Encell LP, Zimmerman K, Forsyth SK, Rehrauer WM, Accola MA, Hsu CC, Machleidt T, Dart ML. Development of a rapid, simple, and sensitive point-of-care technology platform utilizing ternary NanoLuc. Front Microbiol 2022; 13:970233. [PMID: 36386626 PMCID: PMC9643700 DOI: 10.3389/fmicb.2022.970233] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/27/2022] [Accepted: 10/06/2022] [Indexed: 12/02/2022] Open
Abstract
Point-of-care tests are highly valuable in providing fast results for medical decisions for greater flexibility in patient care. Many diagnostic tests, such as ELISAs, that are commonly used within clinical laboratory settings require trained technicians, laborious workflows, and complex instrumentation hindering their translation into point-of-care applications. Herein, we demonstrate the use of a homogeneous, bioluminescent-based, split reporter platform that enables a simple, sensitive, and rapid method for analyte detection in clinical samples. We developed this point-of-care application using an optimized ternary, split-NanoLuc luciferase reporter system that consists of two small reporter peptides added as appendages to analyte-specific affinity reagents. A bright, stable bioluminescent signal is generated as the affinity reagents bind to the analyte, allowing for proximity-induced complementation between the two reporter peptides and the polypeptide protein, in addition to the furimazine substrate. Through lyophilization of the stabilized reporter system with the formulated substrate, we demonstrate a shelf-stable, all-in-one, add-and-read analyte-detection system for use in complex sample matrices at the point-of-care. We highlight the modularity of this platform using two distinct SARS-CoV-2 model systems: SARS-CoV-2 N-antigen detection for active infections and anti-SARS-CoV-2 antibodies for immunity status detection using chemically conjugated or genetically fused affinity reagents, respectively. This technology provides a simple and standardized method to develop rapid, robust, and sensitive analyte-detection assays with flexible assay formatting making this an ideal platform for research, clinical laboratory, as well as point-of-care applications utilizing a simple handheld luminometer.
Collapse
Affiliation(s)
| | | | | | - Robin Hurst
- Promega Corporation, Madison, WI, United States
| | - Mary P Hall
- Promega Corporation, Madison, WI, United States
| | | | | | | | - William M Rehrauer
- Department of Pathology and Laboratory Medicine, School of Medicine and Public Health, University of Wisconsin-Madison, Madison, WI, United States
- University of Wisconsin Hospital and Clinics, Clinical Laboratories, Madison, WI, United States
| | - Molly A Accola
- University of Wisconsin Hospital and Clinics, Clinical Laboratories, Madison, WI, United States
| | | | | | | |
Collapse
|
8
|
Wu Y, Jiang T. Developments in FRET- and BRET-Based Biosensors. MICROMACHINES 2022; 13:mi13101789. [PMID: 36296141 PMCID: PMC9610962 DOI: 10.3390/mi13101789] [Citation(s) in RCA: 18] [Impact Index Per Article: 6.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 09/13/2022] [Revised: 10/14/2022] [Accepted: 10/17/2022] [Indexed: 05/25/2023]
Abstract
Resonance energy transfer technologies have achieved great success in the field of analysis. Particularly, fluorescence resonance energy transfer (FRET) and bioluminescence resonance energy transfer (BRET) provide strategies to design tools for sensing molecules and monitoring biological processes, which promote the development of biosensors. Here, we provide an overview of recent progress on FRET- and BRET-based biosensors and their roles in biomedicine, environmental applications, and synthetic biology. This review highlights FRET- and BRET-based biosensors and gives examples of their applications with their design strategies. The limitations of their applications and the future directions of their development are also discussed.
Collapse
Affiliation(s)
- Yuexin Wu
- School of Life Sciences, Peking University, Beijing 100871, China
| | - Tianyu Jiang
- Shenzhen Research Institute of Shandong University, Shenzhen 518000, China
- State Key Laboratory of Microbial Technology, Institute of Microbial Technology, Helmholtz International Lab for Anti-Infectives, Shandong University-Helmholtz Institute of Biotechnology, Shandong University, Qingdao 266237, China
| |
Collapse
|
9
|
Liquid Crystal Droplet-Based Biosensors: Promising for Point-of-Care Testing. BIOSENSORS 2022; 12:bios12090758. [PMID: 36140143 PMCID: PMC9496589 DOI: 10.3390/bios12090758] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 08/01/2022] [Revised: 09/04/2022] [Accepted: 09/09/2022] [Indexed: 01/07/2023]
Abstract
The development of biosensing platforms has been impressively accelerated by advancements in liquid crystal (LC) technology. High response rate, easy operation, and good stability of the LC droplet-based biosensors are all benefits of the long-range order of LC molecules. Bioprobes emerged when LC droplets were combined with biotechnology, and these bioprobes are used extensively for disease diagnosis, food safety, and environmental monitoring. The LC droplet biosensors have high sensitivity and excellent selectivity, making them an attractive tool for the label-free, economical, and real-time detection of different targets. Portable devices work well as the accessory kits for LC droplet-based biosensors to make them easier to use by anyone for on-site monitoring of targets. Herein, we offer a review of the latest developments in the design of LC droplet-based biosensors for qualitative target monitoring and quantitative target analysis.
Collapse
|
10
|
Li J, Wang JL, Zhang WL, Tu Z, Cai XF, Wang YW, Gan CY, Deng HJ, Cui J, Shu ZC, Long QX, Chen J, Tang N, Hu X, Huang AL, Hu JL. Protein sensors combining both on-and-off model for antibody homogeneous assay. Biosens Bioelectron 2022; 209:114226. [PMID: 35413624 PMCID: PMC8968183 DOI: 10.1016/j.bios.2022.114226] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/30/2021] [Revised: 03/14/2022] [Accepted: 03/25/2022] [Indexed: 01/03/2023]
Abstract
Protein sensors based on allosteric enzymes responding to target binding with rapid changes in enzymatic activity are potential tools for homogeneous assays. However, a high signal-to-noise ratio (S/N) is difficult to achieve in their construction. A high S/N is critical to discriminate signals from the background, a phenomenon that might largely vary among serum samples from different individuals. Herein, based on the modularized luciferase NanoLuc, we designed a novel biosensor called NanoSwitch. This sensor allows direct detection of antibodies in 1 μl serum in 45 min without washing steps. In the detection of Flag and HA antibodies, NanoSwitches respond to antibodies with S/N ratios of 33-fold and 42-fold, respectively. Further, we constructed a NanoSwitch for detecting SARS-CoV-2-specific antibodies, which showed over 200-fold S/N in serum samples. High S/N was achieved by a new working model, combining the turn-off of the sensor with human serum albumin and turn-on with a specific antibody. Also, we constructed NanoSwitches for detecting antibodies against the core protein of hepatitis C virus (HCV) and gp41 of the human immunodeficiency virus (HIV). Interestingly, these sensors demonstrated a high S/N and good performance in the assays of clinical samples; this was partly attributed to the combination of off-and-on models. In summary, we provide a novel type of protein sensor and a working model that potentially guides new sensor design with better performance.
Collapse
|
11
|
Kinnamon DS, Heggestad JT, Liu J, Chilkoti A. Technologies for Frugal and Sensitive Point-of-Care Immunoassays. ANNUAL REVIEW OF ANALYTICAL CHEMISTRY (PALO ALTO, CALIF.) 2022; 15:123-149. [PMID: 35216530 PMCID: PMC10024863 DOI: 10.1146/annurev-anchem-061020-123817] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/14/2023]
Abstract
Immunoassays are a powerful tool for sensitive and quantitative analysis of a wide range of biomolecular analytes in the clinic and in research laboratories. However, enzyme-linked immunosorbent assay (ELISA)-the gold-standard assay-requires significant user intervention, time, and clinical resources, making its deployment at the point-of-care (POC) impractical. Researchers have made great strides toward democratizing access to clinical quality immunoassays at the POC and at an affordable price. In this review, we first summarize the commercially available options that offer high performance, albeit at high cost. Next, we describe strategies for the development of frugal POC assays that repurpose consumer electronics and smartphones for the quantitative detection of analytes. Finally, we discuss innovative assay formats that enable highly sensitive analysis in the field with simple instrumentation.
Collapse
Affiliation(s)
- David S Kinnamon
- Department of Biomedical Engineering, Pratt School of Engineering, Duke University, Durham, North Carolina, USA;
| | - Jacob T Heggestad
- Department of Biomedical Engineering, Pratt School of Engineering, Duke University, Durham, North Carolina, USA;
| | - Jason Liu
- Department of Biomedical Engineering, Pratt School of Engineering, Duke University, Durham, North Carolina, USA;
| | - Ashutosh Chilkoti
- Department of Biomedical Engineering, Pratt School of Engineering, Duke University, Durham, North Carolina, USA;
| |
Collapse
|
12
|
A plug-and-play platform of ratiometric bioluminescent sensors for homogeneous immunoassays. Nat Commun 2021; 12:4586. [PMID: 34321486 PMCID: PMC8319308 DOI: 10.1038/s41467-021-24874-3] [Citation(s) in RCA: 43] [Impact Index Per Article: 10.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/09/2020] [Accepted: 07/08/2021] [Indexed: 01/07/2023] Open
Abstract
Heterogeneous immunoassays such as ELISA have become indispensable in modern bioanalysis, yet translation into point-of-care assays is hindered by their dependence on external calibration and multiple washing and incubation steps. Here, we introduce RAPPID (Ratiometric Plug-and-Play Immunodiagnostics), a mix-and-measure homogeneous immunoassay platform that combines highly specific antibody-based detection with a ratiometric bioluminescent readout. The concept entails analyte-induced complementation of split NanoLuc luciferase fragments, photoconjugated to an antibody sandwich pair via protein G adapters. Introduction of a calibrator luciferase provides a robust ratiometric signal that allows direct in-sample calibration and quantitative measurements in complex media such as blood plasma. We developed RAPPID sensors that allow low-picomolar detection of several protein biomarkers, anti-drug antibodies, therapeutic antibodies, and both SARS-CoV-2 spike protein and anti-SARS-CoV-2 antibodies. With its easy-to-implement standardized workflow, RAPPID provides an attractive, fast, and low-cost alternative to traditional immunoassays, in an academic setting, in clinical laboratories, and for point-of-care applications. Many current immunoassays require multiple washing, incubation and optimization steps. Here the authors present Ratiometric Plug-and-Play Immunodiagnostics (RAPPID), a generic assay platform that uses ratiometric bioluminescent detection to allow sandwich immunoassays to be performed directly in solution.
Collapse
|
13
|
Fairbanks BD, Macdougall LJ, Mavila S, Sinha J, Kirkpatrick BE, Anseth KS, Bowman CN. Photoclick Chemistry: A Bright Idea. Chem Rev 2021; 121:6915-6990. [PMID: 33835796 PMCID: PMC9883840 DOI: 10.1021/acs.chemrev.0c01212] [Citation(s) in RCA: 118] [Impact Index Per Article: 29.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/08/2023]
Abstract
At its basic conceptualization, photoclick chemistry embodies a collection of click reactions that are performed via the application of light. The emergence of this concept has had diverse impact over a broad range of chemical and biological research due to the spatiotemporal control, high selectivity, and excellent product yields afforded by the combination of light and click chemistry. While the reactions designated as "photoclick" have many important features in common, each has its own particular combination of advantages and shortcomings. A more extensive realization of the potential of this chemistry requires a broader understanding of the physical and chemical characteristics of the specific reactions. This review discusses the features of the most frequently employed photoclick reactions reported in the literature: photomediated azide-alkyne cycloadditions, other 1,3-dipolarcycloadditions, Diels-Alder and inverse electron demand Diels-Alder additions, radical alternating addition chain transfer additions, and nucleophilic additions. Applications of these reactions in a variety of chemical syntheses, materials chemistry, and biological contexts are surveyed, with particular attention paid to the respective strengths and limitations of each reaction and how that reaction benefits from its combination with light. Finally, challenges to broader employment of these reactions are discussed, along with strategies and opportunities to mitigate such obstacles.
Collapse
Affiliation(s)
- Benjamin D Fairbanks
- Department of Chemical and Biological Engineering, University of Colorado, Boulder, Colorado 80303, United States
| | - Laura J Macdougall
- Department of Chemical and Biological Engineering, University of Colorado, Boulder, Colorado 80303, United States
| | - Sudheendran Mavila
- Department of Chemical and Biological Engineering, University of Colorado, Boulder, Colorado 80303, United States
| | - Jasmine Sinha
- Department of Chemical and Biological Engineering, University of Colorado, Boulder, Colorado 80303, United States
| | - Bruce E Kirkpatrick
- Department of Chemical and Biological Engineering, University of Colorado, Boulder, Colorado 80303, United States
- The BioFrontiers Institute, University of Colorado, Boulder, Colorado 80303, United States
- Medical Scientist Training Program, School of Medicine, University of Colorado, Aurora, Coorado 80045, United States
| | - Kristi S Anseth
- Department of Chemical and Biological Engineering, University of Colorado, Boulder, Colorado 80303, United States
- The BioFrontiers Institute, University of Colorado, Boulder, Colorado 80303, United States
| | - Christopher N Bowman
- Department of Chemical and Biological Engineering, University of Colorado, Boulder, Colorado 80303, United States
- Materials Science and Engineering Program, University of Colorado, Boulder, Colorado 80303, United States
| |
Collapse
|
14
|
Farag N, Mattossovich R, Merlo R, Nierzwicki Ł, Palermo G, Porchetta A, Perugino G, Ricci F. Folding-upon-Repair DNA Nanoswitches for Monitoring the Activity of DNA Repair Enzymes. Angew Chem Int Ed Engl 2021; 60:7283-7289. [PMID: 33415794 PMCID: PMC8783695 DOI: 10.1002/anie.202016223] [Citation(s) in RCA: 29] [Impact Index Per Article: 7.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/07/2020] [Indexed: 09/28/2023]
Abstract
We present a new class of DNA-based nanoswitches that, upon enzymatic repair, could undergo a conformational change mechanism leading to a change in fluorescent signal. Such folding-upon-repair DNA nanoswitches are synthetic DNA sequences containing O6 -methyl-guanine (O6 -MeG) nucleobases and labelled with a fluorophore/quencher optical pair. The nanoswitches are rationally designed so that only upon enzymatic demethylation of the O6 -MeG nucleobases they can form stable intramolecular Hoogsteen interactions and fold into an optically active triplex DNA structure. We have first characterized the folding mechanism induced by the enzymatic repair activity through fluorescent experiments and Molecular Dynamics simulations. We then demonstrated that the folding-upon-repair DNA nanoswitches are suitable and specific substrates for different methyltransferase enzymes including the human homologue (hMGMT) and they allow the screening of novel potential methyltransferase inhibitors.
Collapse
Affiliation(s)
- Nada Farag
- Department of Chemistry, University of Rome Tor Vergata, Via della Ricerca Scientifica, 00133, Rome, Italy
| | - Rosanna Mattossovich
- Institute of Biosciences and BioResources, National Research Council of Italy, Via Pietro Castellino 111, 80131, Naples, Italy
| | - Rosa Merlo
- Institute of Biosciences and BioResources, National Research Council of Italy, Via Pietro Castellino 111, 80131, Naples, Italy
| | - Łukasz Nierzwicki
- Department of Bioengineering, University of California Riverside, 900 University Avenue, Riverside, CA, 52512, USA
| | - Giulia Palermo
- Department of Bioengineering, University of California Riverside, 900 University Avenue, Riverside, CA, 52512, USA
- Department of Chemistry, University of California Riverside, 900 University Avenue, Riverside, CA, 52512, USA
| | - Alessandro Porchetta
- Department of Chemistry, University of Rome Tor Vergata, Via della Ricerca Scientifica, 00133, Rome, Italy
| | - Giuseppe Perugino
- Institute of Biosciences and BioResources, National Research Council of Italy, Via Pietro Castellino 111, 80131, Naples, Italy
| | - Francesco Ricci
- Department of Chemistry, University of Rome Tor Vergata, Via della Ricerca Scientifica, 00133, Rome, Italy
| |
Collapse
|
15
|
Quijano-Rubio A, Yeh HW, Park J, Lee H, Langan RA, Boyken SE, Lajoie MJ, Cao L, Chow CM, Miranda MC, Wi J, Hong HJ, Stewart L, Oh BH, Baker D. De novo design of modular and tunable protein biosensors. Nature 2021; 591:482-487. [PMID: 33503651 PMCID: PMC8074680 DOI: 10.1038/s41586-021-03258-z] [Citation(s) in RCA: 148] [Impact Index Per Article: 37.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/13/2020] [Accepted: 01/19/2021] [Indexed: 01/30/2023]
Abstract
Naturally occurring protein switches have been repurposed for the development of biosensors and reporters for cellular and clinical applications1. However, the number of such switches is limited, and reengineering them is challenging. Here we show that a general class of protein-based biosensors can be created by inverting the flow of information through de novo designed protein switches in which the binding of a peptide key triggers biological outputs of interest2. The designed sensors are modular molecular devices with a closed dark state and an open luminescent state; analyte binding drives the switch from the closed to the open state. Because the sensor is based on the thermodynamic coupling of analyte binding to sensor activation, only one target binding domain is required, which simplifies sensor design and allows direct readout in solution. We create biosensors that can sensitively detect the anti-apoptosis protein BCL-2, the IgG1 Fc domain, the HER2 receptor, and Botulinum neurotoxin B, as well as biosensors for cardiac troponin I and an anti-hepatitis B virus antibody with the high sensitivity required to detect these molecules clinically. Given the need for diagnostic tools to track the severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2)3, we used the approach to design sensors for the SARS-CoV-2 spike protein and antibodies against the membrane and nucleocapsid proteins. The former, which incorporates a de novo designed spike receptor binding domain (RBD) binder4, has a limit of detection of 15 pM and a luminescence signal 50-fold higher than the background level. The modularity and sensitivity of the platform should enable the rapid construction of sensors for a wide range of analytes, and highlights the power of de novo protein design to create multi-state protein systems with new and useful functions.
Collapse
Affiliation(s)
- Alfredo Quijano-Rubio
- Department of Biochemistry and Institute for Protein Design, University of Washington, Seattle, Washington 98195, USA,Department of Bioengineering, University of Washington, Seattle, Washington 98195, USA
| | - Hsien-Wei Yeh
- Department of Biochemistry and Institute for Protein Design, University of Washington, Seattle, Washington 98195, USA
| | - Jooyoung Park
- Department of Biochemistry and Institute for Protein Design, University of Washington, Seattle, Washington 98195, USA
| | - Hansol Lee
- Department of Biological Sciences, KAIST Institute for the Biocentury, Korea Advanced Institute of Science and Technology, Daejeon 34141, Republic of Korea
| | - Robert A. Langan
- Department of Biochemistry and Institute for Protein Design, University of Washington, Seattle, Washington 98195, USA
| | - Scott E. Boyken
- Department of Biochemistry and Institute for Protein Design, University of Washington, Seattle, Washington 98195, USA
| | - Marc J. Lajoie
- Department of Biochemistry and Institute for Protein Design, University of Washington, Seattle, Washington 98195, USA
| | - Longxing Cao
- Department of Biochemistry and Institute for Protein Design, University of Washington, Seattle, Washington 98195, USA
| | - Cameron M. Chow
- Department of Biochemistry and Institute for Protein Design, University of Washington, Seattle, Washington 98195, USA
| | - Marcos C. Miranda
- Department of Biochemistry and Institute for Protein Design, University of Washington, Seattle, Washington 98195, USA
| | - Jimin Wi
- Department of Systems Immunology, College of Biomedical Science, Kangwon National University, Chuncheon 200-701, Republic of Korea
| | - Hyo Jeong Hong
- Department of Systems Immunology, College of Biomedical Science, Kangwon National University, Chuncheon 200-701, Republic of Korea
| | - Lance Stewart
- Department of Biochemistry and Institute for Protein Design, University of Washington, Seattle, Washington 98195, USA
| | - Byung-Ha Oh
- Department of Biochemistry and Institute for Protein Design, University of Washington, Seattle, Washington 98195, USA,Department of Biological Sciences, KAIST Institute for the Biocentury, Korea Advanced Institute of Science and Technology, Daejeon 34141, Republic of Korea,Correspondence and requests for materials should be addressed to D.B. or B.-H.O
| | - David Baker
- Department of Biochemistry and Institute for Protein Design, University of Washington, Seattle, Washington 98195, USA,Howard Hughes Medical Institute, University of Washington, Seattle, Washington 98195, USA,Correspondence and requests for materials should be addressed to D.B. or B.-H.O
| |
Collapse
|
16
|
Farag N, Mattossovich R, Merlo R, Nierzwicki Ł, Palermo G, Porchetta A, Perugino G, Ricci F. Folding‐upon‐Repair DNA Nanoswitches for Monitoring the Activity of DNA Repair Enzymes. Angew Chem Int Ed Engl 2021. [DOI: 10.1002/ange.202016223] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/06/2023]
Affiliation(s)
- Nada Farag
- Department of Chemistry University of Rome Tor Vergata Via della Ricerca Scientifica 00133 Rome Italy
| | - Rosanna Mattossovich
- Institute of Biosciences and BioResources National Research Council of Italy Via Pietro Castellino 111 80131 Naples Italy
| | - Rosa Merlo
- Institute of Biosciences and BioResources National Research Council of Italy Via Pietro Castellino 111 80131 Naples Italy
| | - Łukasz Nierzwicki
- Department of Bioengineering University of California Riverside 900 University Avenue Riverside CA 52512 USA
| | - Giulia Palermo
- Department of Bioengineering University of California Riverside 900 University Avenue Riverside CA 52512 USA
- Department of Chemistry University of California Riverside 900 University Avenue Riverside CA 52512 USA
| | - Alessandro Porchetta
- Department of Chemistry University of Rome Tor Vergata Via della Ricerca Scientifica 00133 Rome Italy
| | - Giuseppe Perugino
- Institute of Biosciences and BioResources National Research Council of Italy Via Pietro Castellino 111 80131 Naples Italy
| | - Francesco Ricci
- Department of Chemistry University of Rome Tor Vergata Via della Ricerca Scientifica 00133 Rome Italy
| |
Collapse
|
17
|
Weihs F, Anderson A, Trowell S, Caron K. Resonance Energy Transfer-Based Biosensors for Point-of-Need Diagnosis-Progress and Perspectives. SENSORS (BASEL, SWITZERLAND) 2021; 21:660. [PMID: 33477883 PMCID: PMC7833371 DOI: 10.3390/s21020660] [Citation(s) in RCA: 14] [Impact Index Per Article: 3.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 12/17/2020] [Revised: 01/08/2021] [Accepted: 01/15/2021] [Indexed: 02/06/2023]
Abstract
The demand for point-of-need (PON) diagnostics for clinical and other applications is continuing to grow. Much of this demand is currently serviced by biosensors, which combine a bioanalytical sensing element with a transducing device that reports results to the user. Ideally, such devices are easy to use and do not require special skills of the end user. Application-dependent, PON devices may need to be capable of measuring low levels of analytes very rapidly, and it is often helpful if they are also portable. To date, only two transduction modalities, colorimetric lateral flow immunoassays (LFIs) and electrochemical assays, fully meet these requirements and have been widely adopted at the point-of-need. These modalities are either non-quantitative (LFIs) or highly analyte-specific (electrochemical glucose meters), therefore requiring considerable modification if they are to be co-opted for measuring other biomarkers. Förster Resonance Energy Transfer (RET)-based biosensors incorporate a quantitative and highly versatile transduction modality that has been extensively used in biomedical research laboratories. RET-biosensors have not yet been applied at the point-of-need despite its advantages over other established techniques. In this review, we explore and discuss recent developments in the translation of RET-biosensors for PON diagnoses, including their potential benefits and drawbacks.
Collapse
Affiliation(s)
- Felix Weihs
- CSIRO Health & Biosecurity, Parkville, 343 Royal Parade, Melbourne, VIC 3030, Australia;
| | - Alisha Anderson
- CSIRO Health & Biosecurity, Black Mountain, Canberra, ACT 2600, Australia;
| | - Stephen Trowell
- PPB Technology Pty Ltd., Centre for Entrepreneurial Agri-Technology, Australian National University, Canberra, ACT 2601, Australia;
| | - Karine Caron
- CSIRO Health & Biosecurity, Black Mountain, Canberra, ACT 2600, Australia;
| |
Collapse
|
18
|
Intracellular Ionic Strength Sensing Using NanoLuc. Int J Mol Sci 2021; 22:ijms22020677. [PMID: 33445497 PMCID: PMC7826950 DOI: 10.3390/ijms22020677] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Key Words] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/23/2020] [Revised: 12/28/2020] [Accepted: 12/29/2020] [Indexed: 12/20/2022] Open
Abstract
Intracellular ionic strength regulates myriad cellular processes that are fundamental to cellular survival and proliferation, including protein activity, aggregation, phase separation, and cell volume. It could be altered by changes in the activity of cellular signaling pathways, such as those that impact the activity of membrane-localized ion channels or by alterations in the microenvironmental osmolarity. Therefore, there is a demand for the development of sensitive tools for real-time monitoring of intracellular ionic strength. Here, we developed a bioluminescence-based intracellular ionic strength sensing strategy using the Nano Luciferase (NanoLuc) protein that has gained tremendous utility due to its high, long-lived bioluminescence output and thermal stability. Biochemical experiments using a recombinantly purified protein showed that NanoLuc bioluminescence is dependent on the ionic strength of the reaction buffer for a wide range of ionic strength conditions. Importantly, the decrease in the NanoLuc activity observed at higher ionic strengths could be reversed by decreasing the ionic strength of the reaction, thus making it suitable for sensing intracellular ionic strength alterations. Finally, we used an mNeonGreen–NanoLuc fusion protein to successfully monitor ionic strength alterations in a ratiometric manner through independent fluorescence and bioluminescence measurements in cell lysates and live cells. We envisage that the biosensing strategy developed here for detecting alterations in intracellular ionic strength will be applicable in a wide range of experiments, including high throughput cellular signaling, ion channel functional genomics, and drug discovery.
Collapse
|
19
|
Syed AJ, Anderson JC. Applications of bioluminescence in biotechnology and beyond. Chem Soc Rev 2021; 50:5668-5705. [DOI: 10.1039/d0cs01492c] [Citation(s) in RCA: 51] [Impact Index Per Article: 12.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/30/2022]
Abstract
Bioluminescent probes have hugely benefited from the input of synthetic chemistry and protein engineering. Here we review the latest applications of these probes in biotechnology and beyond, with an eye on current limitations and future directions.
Collapse
Affiliation(s)
- Aisha J. Syed
- Department of Chemistry
- University College London
- London
- UK
| | | |
Collapse
|
20
|
Abstract
Biological signaling pathways are underpinned by protein switches that sense and respond to molecular inputs. Inspired by nature, engineered protein switches have been designed to directly transduce analyte binding into a quantitative signal in a simple, wash-free, homogeneous assay format. As such, they offer great potential to underpin point-of-need diagnostics that are needed across broad sectors to improve access, costs, and speed compared to laboratory assays. Despite this, protein switch assays are not yet in routine diagnostic use, and a number of barriers to uptake must be overcome to realize this potential. Here, we review the opportunities and challenges in engineering protein switches for rapid diagnostic tests. We evaluate how their design, comprising a recognition element, reporter, and switching mechanism, relates to performance and identify areas for improvement to guide further optimization. Recent modular switches that enable new analytes to be targeted without redesign are crucial to ensure robust and efficient development processes. The importance of translational steps toward practical implementation, including integration into a user-friendly device and thorough assay validation, is also discussed.
Collapse
Affiliation(s)
- Hope Adamson
- School of Biomedical Sciences, University of Leeds, Leeds LS2 9JT, United Kingdom
| | - Lars J. C. Jeuken
- School of Biomedical Sciences, University of Leeds, Leeds LS2 9JT, United Kingdom
| |
Collapse
|
21
|
Krasitskaya VV, Bashmakova EE, Frank LA. Coelenterazine-Dependent Luciferases as a Powerful Analytical Tool for Research and Biomedical Applications. Int J Mol Sci 2020; 21:E7465. [PMID: 33050422 PMCID: PMC7590018 DOI: 10.3390/ijms21207465] [Citation(s) in RCA: 24] [Impact Index Per Article: 4.8] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/28/2020] [Revised: 10/05/2020] [Accepted: 10/07/2020] [Indexed: 12/19/2022] Open
Abstract
: The functioning of bioluminescent systems in most of the known marine organisms is based on the oxidation reaction of the same substrate-coelenterazine (CTZ), catalyzed by luciferase. Despite the diversity in structures and the functioning mechanisms, these enzymes can be united into a common group called CTZ-dependent luciferases. Among these, there are two sharply different types of the system organization-Ca2+-regulated photoproteins and luciferases themselves that function in accordance with the classical enzyme-substrate kinetics. Along with deep and comprehensive fundamental research on these systems, approaches and methods of their practical use as highly sensitive reporters in analytics have been developed. The research aiming at the creation of artificial luciferases and synthetic CTZ analogues with new unique properties has led to the development of new experimental analytical methods based on them. The commercial availability of many ready-to-use assay systems based on CTZ-dependent luciferases is also important when choosing them by first-time-users. The development of analytical methods based on these bioluminescent systems is currently booming. The bioluminescent systems under consideration were successfully applied in various biological research areas, which confirms them to be a powerful analytical tool. In this review, we consider the main directions, results, and achievements in research involving these luciferases.
Collapse
Affiliation(s)
- Vasilisa V. Krasitskaya
- Institute of Biophysics SB RAS, Federal Research Center “Krasnoyarsk Science Center SB RAS”, 660036 Krasnoyarsk, Russia; (V.V.K.); (E.E.B.)
| | - Eugenia E. Bashmakova
- Institute of Biophysics SB RAS, Federal Research Center “Krasnoyarsk Science Center SB RAS”, 660036 Krasnoyarsk, Russia; (V.V.K.); (E.E.B.)
| | - Ludmila A. Frank
- Institute of Biophysics SB RAS, Federal Research Center “Krasnoyarsk Science Center SB RAS”, 660036 Krasnoyarsk, Russia; (V.V.K.); (E.E.B.)
- School of Fundamental Biology and Biotechnology, Siberian Federal University, 660041 Krasnoyarsk, Russia
| |
Collapse
|
22
|
Quijano-Rubio A, Yeh HW, Park J, Lee H, Langan RA, Boyken SE, Lajoie MJ, Cao L, Chow CM, Miranda MC, Wi J, Hong HJ, Stewart L, Oh BH, Baker D. De novo design of modular and tunable allosteric biosensors. BIORXIV : THE PREPRINT SERVER FOR BIOLOGY 2020. [PMID: 32743576 DOI: 10.1101/2020.07.18.206946] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 02/07/2023]
Abstract
Naturally occurring allosteric protein switches have been repurposed for developing novel biosensors and reporters for cellular and clinical applications 1 , but the number of such switches is limited, and engineering them is often challenging as each is different. Here, we show that a very general class of allosteric protein-based biosensors can be created by inverting the flow of information through de novo designed protein switches in which binding of a peptide key triggers biological outputs of interest 2 . Using broadly applicable design principles, we allosterically couple binding of protein analytes of interest to the reconstitution of luciferase activity and a bioluminescent readout through the association of designed lock and key proteins. Because the sensor is based purely on thermodynamic coupling of analyte binding to switch activation, only one target binding domain is required, which simplifies sensor design and allows direct readout in solution. We demonstrate the modularity of this platform by creating biosensors that, with little optimization, sensitively detect the anti-apoptosis protein Bcl-2, the hIgG1 Fc domain, the Her2 receptor, and Botulinum neurotoxin B, as well as biosensors for cardiac Troponin I and an anti-Hepatitis B virus (HBV) antibody that achieve the sub-nanomolar sensitivity necessary to detect clinically relevant concentrations of these molecules. Given the current need for diagnostic tools for tracking COVID-19 3 , we use the approach to design sensors of antibodies against SARS-CoV-2 protein epitopes and of the receptor-binding domain (RBD) of the SARS-CoV-2 Spike protein. The latter, which incorporates a de novo designed RBD binder, has a limit of detection of 15pM with an up to seventeen fold increase in luminescence upon addition of RBD. The modularity and sensitivity of the platform should enable the rapid construction of sensors for a wide range of analytes and highlights the power of de novo protein design to create multi-state protein systems with new and useful functions.
Collapse
|
23
|
Tomimuro K, Tenda K, Ni Y, Hiruta Y, Merkx M, Citterio D. Thread-Based Bioluminescent Sensor for Detecting Multiple Antibodies in a Single Drop of Whole Blood. ACS Sens 2020; 5:1786-1794. [PMID: 32441095 DOI: 10.1021/acssensors.0c00564] [Citation(s) in RCA: 41] [Impact Index Per Article: 8.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/20/2022]
Abstract
Antibodies are important biomarkers in clinical diagnostics in addition to being increasingly used for therapeutic purposes. Although numerous methods for their detection and quantification exist, they predominantly require benchtop instruments operated by specialists. To enable the detection of antibodies at point-of-care (POC), the development of simple and rapid assay methods independent of laboratory equipment is of high relevance. In this study, we demonstrate microfluidic thread-based analytical devices (μTADs) as a new platform for antibody detection by means of bioluminescence resonance energy-transfer (BRET) switching sensor proteins. The devices consist of vertically assembled layers including a blood separation membrane and a plastic film with a sewn-in cotton thread, onto which the BRET sensor proteins together with the substrate furimazine have been predeposited. In contrast to intensity-based signaling, the BRET mechanism enables time-independent, ratiometric readout of bioluminescence signals with a digital camera in a darkroom or a smartphone camera with a 3D-printed lens adapter. The device design allows spatially separated deposition of multiple bioluminescent proteins on a single sewn thread, enabling quantification of multiple antibodies in 5 μL of whole blood within 5 min. The bioluminescence response is independent of the applied sample volume within the range of 5-15 μL. Therefore, μTADs in combination with BRET-based sensor proteins represent user-friendly analytical tools for POC quantification of antibodies without any laboratory equipment in a finger prick (5 μL) of whole blood.
Collapse
Affiliation(s)
- Kosuke Tomimuro
- Department of Applied Chemistry, Keio University, 3-14-1 Hiyoshi,
Kohoku-ku, 223-8522 Yokohama, Japan
| | - Keisuke Tenda
- Department of Applied Chemistry, Keio University, 3-14-1 Hiyoshi,
Kohoku-ku, 223-8522 Yokohama, Japan
| | - Yan Ni
- Laboratory of Chemical Biology and Institute for Complex Molecular Systems, Department of Biomedical Engineering, Eindhoven University of Technology, P.O. Box 513, 5600 MB Eindhoven, The Netherlands
| | - Yuki Hiruta
- Department of Applied Chemistry, Keio University, 3-14-1 Hiyoshi,
Kohoku-ku, 223-8522 Yokohama, Japan
| | - Maarten Merkx
- Department of Applied Chemistry, Keio University, 3-14-1 Hiyoshi,
Kohoku-ku, 223-8522 Yokohama, Japan
- Laboratory of Chemical Biology and Institute for Complex Molecular Systems, Department of Biomedical Engineering, Eindhoven University of Technology, P.O. Box 513, 5600 MB Eindhoven, The Netherlands
| | - Daniel Citterio
- Department of Applied Chemistry, Keio University, 3-14-1 Hiyoshi,
Kohoku-ku, 223-8522 Yokohama, Japan
| |
Collapse
|
24
|
Yan J, van Smeden L, Merkx M, Zijlstra P, Prins MWJ. Continuous Small-Molecule Monitoring with a Digital Single-Particle Switch. ACS Sens 2020; 5:1168-1176. [PMID: 32189498 PMCID: PMC8177406 DOI: 10.1021/acssensors.0c00220] [Citation(s) in RCA: 14] [Impact Index Per Article: 2.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/30/2022]
Abstract
![]()
The
ability to continuously measure concentrations of small molecules
is important for biomedical, environmental, and industrial monitoring.
However, because of their low molecular mass, it is difficult to quantify
concentrations of such molecules, particularly at low concentrations.
Here, we describe a small-molecule sensor that is generalizable, sensitive,
specific, reversible, and suited for continuous monitoring over long
durations. The sensor consists of particles attached to a sensing
surface via a double-stranded DNA tether. The particles transiently
bind to the sensing surface via single-molecular affinity interactions,
and the transient binding is optically detected as digital binding
events via the Brownian motion of the particles. The rate of binding
events decreases with increasing analyte concentration because analyte
molecules inhibit binding of the tethered particle to the surface.
The sensor enables continuous measurements of analyte concentrations
because of the reversibility of the intermolecular bonds and digital
read-out of particle motion. We show results for the monitoring of
short single-stranded DNA sequences and creatinine, a small-molecule
biomarker (113 Da) for kidney function, demonstrating a temporal resolution
of a few minutes. The precision of the sensor is determined by the
statistics of the digital switching events, which means that the precision
is tunable by the number of particles and the measurement time.
Collapse
Affiliation(s)
- Junhong Yan
- Department of Biomedical Engineering, Eindhoven University of Technology, Eindhoven 5612 AZ, The Netherlands
- Institute for Complex Molecular Systems (ICMS), Eindhoven University of Technology, Eindhoven 5612 AZ, The Netherlands
| | - Laura van Smeden
- Department of Biomedical Engineering, Eindhoven University of Technology, Eindhoven 5612 AZ, The Netherlands
- Institute for Complex Molecular Systems (ICMS), Eindhoven University of Technology, Eindhoven 5612 AZ, The Netherlands
| | - Maarten Merkx
- Department of Biomedical Engineering, Eindhoven University of Technology, Eindhoven 5612 AZ, The Netherlands
- Institute for Complex Molecular Systems (ICMS), Eindhoven University of Technology, Eindhoven 5612 AZ, The Netherlands
| | - Peter Zijlstra
- Department of Applied Physics, Eindhoven University of Technology, Eindhoven 5612 AZ, The Netherlands
- Institute for Complex Molecular Systems (ICMS), Eindhoven University of Technology, Eindhoven 5612 AZ, The Netherlands
| | - Menno W. J. Prins
- Department of Biomedical Engineering, Eindhoven University of Technology, Eindhoven 5612 AZ, The Netherlands
- Department of Applied Physics, Eindhoven University of Technology, Eindhoven 5612 AZ, The Netherlands
- Institute for Complex Molecular Systems (ICMS), Eindhoven University of Technology, Eindhoven 5612 AZ, The Netherlands
| |
Collapse
|
25
|
Pirzada M, Altintas Z. Recent Progress in Optical Sensors for Biomedical Diagnostics. MICROMACHINES 2020; 11:E356. [PMID: 32235546 PMCID: PMC7231100 DOI: 10.3390/mi11040356] [Citation(s) in RCA: 52] [Impact Index Per Article: 10.4] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 03/01/2020] [Revised: 03/25/2020] [Accepted: 03/28/2020] [Indexed: 12/12/2022]
Abstract
In recent years, several types of optical sensors have been probed for their aptitude in healthcare biosensing, making their applications in biomedical diagnostics a rapidly evolving subject. Optical sensors show versatility amongst different receptor types and even permit the integration of different detection mechanisms. Such conjugated sensing platforms facilitate the exploitation of their neoteric synergistic characteristics for sensor fabrication. This paper covers nearly 250 research articles since 2016 representing the emerging interest in rapid, reproducible and ultrasensitive assays in clinical analysis. Therefore, we present an elaborate review of biomedical diagnostics with the help of optical sensors working on varied principles such as surface plasmon resonance, localised surface plasmon resonance, evanescent wave fluorescence, bioluminescence and several others. These sensors are capable of investigating toxins, proteins, pathogens, disease biomarkers and whole cells in varied sensing media ranging from water to buffer to more complex environments such as serum, blood or urine. Hence, the recent trends discussed in this review hold enormous potential for the widespread use of optical sensors in early-stage disease prediction and point-of-care testing devices.
Collapse
Affiliation(s)
| | - Zeynep Altintas
- Institute of Chemistry, Technical University of Berlin, Straße des 17. Juni 124, 10623 Berlin, Germany;
| |
Collapse
|
26
|
Adamson H, Ajayi MO, Campbell E, Brachi E, Tiede C, Tang AA, Adams TL, Ford R, Davidson A, Johnson M, McPherson MJ, Tomlinson DC, Jeuken LJC. Affimer-Enzyme-Inhibitor Switch Sensor for Rapid Wash-free Assays of Multimeric Proteins. ACS Sens 2019; 4:3014-3022. [PMID: 31578863 DOI: 10.1021/acssensors.9b01574] [Citation(s) in RCA: 18] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/07/2023]
Abstract
Robust technology is required to underpin rapid point-of-care and in-field diagnostics to improve timely decision making across broad sectors. An attractive strategy combines target recognition and signal generating elements into an "active" enzyme-switch that directly transduces target-binding into a signal. However, approaches that are broadly applicable to diverse targets remain elusive. Here, an enzyme-inhibitor switch sensor was developed by insertion of non-immunoglobulin Affimer binding proteins, between TEM1-β-lactamase and its inhibitor protein, such that target binding disrupts the enzyme-inhibitor complex. Design principles for a successful switch architecture are illustrated by the rapid (min), simple (wash-free), and sensitive (pM) quantification of multimeric target analytes in biological samples (serum, plasma, leaf extracts), across three application areas. A therapeutic antibody (Herceptin), protein biomarker (human C-reactive protein), and plant virus (cow pea mosaic virus) were targeted, demonstrating assays for therapeutic drug monitoring, health diagnostics, and plant pathogen detection, respectively. Batch-to-batch reproducibility, shelf-life stability, and consistency with validated enzyme-linked immunosorbent assay analysis confirm that the principle of an Affimer-enzyme-inhibitor switch provides a platform for point-of-care and in-field diagnostics.
Collapse
Affiliation(s)
| | | | | | | | | | | | | | - Robert Ford
- Avacta Life Sciences Limited, Unit 20, Ash Way, Thorp Arch Estate, Wetherby LS23 7FA, U.K
| | - Alex Davidson
- Avacta Life Sciences Limited, Unit 20, Ash Way, Thorp Arch Estate, Wetherby LS23 7FA, U.K
| | - Matt Johnson
- Avacta Life Sciences Limited, Unit 20, Ash Way, Thorp Arch Estate, Wetherby LS23 7FA, U.K
| | | | | | | |
Collapse
|
27
|
Yeh HW, Ai HW. Development and Applications of Bioluminescent and Chemiluminescent Reporters and Biosensors. ANNUAL REVIEW OF ANALYTICAL CHEMISTRY (PALO ALTO, CALIF.) 2019; 12:129-150. [PMID: 30786216 PMCID: PMC6565457 DOI: 10.1146/annurev-anchem-061318-115027] [Citation(s) in RCA: 129] [Impact Index Per Article: 21.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/08/2023]
Abstract
Although fluorescent reporters and biosensors have become indispensable tools in biological and biomedical fields, fluorescence measurements require external excitation light, thereby limiting their use in thick tissues and live animals. Bioluminescent reporters and biosensors may potentially overcome this hurdle because they use enzyme-catalyzed exothermic biochemical reactions to generate excited-state emitters. This review first introduces the development of bioluminescent reporters, and next, their applications in sensing biological changes in vitro and in vivo as biosensors. Lastly, we discuss chemiluminescent sensors that produce photons in the absence of luciferases. This review aims to explore fundamentals and experimental insights and to emphasize the yet-to-be-reached potential of next-generation luminescent reporters and biosensors.
Collapse
Affiliation(s)
- Hsien-Wei Yeh
- Center for Membrane and Cell Physiology, Department of Molecular Physiology and Biological Physics, and Department of Chemistry, University of Virginia, Charlottesville, Virginia 22908, USA;
| | - Hui-Wang Ai
- Center for Membrane and Cell Physiology, Department of Molecular Physiology and Biological Physics, and Department of Chemistry, University of Virginia, Charlottesville, Virginia 22908, USA;
| |
Collapse
|
28
|
Recent advances in homogenous immunoassays based on resonance energy transfer. Curr Opin Biotechnol 2019; 55:16-22. [DOI: 10.1016/j.copbio.2018.07.003] [Citation(s) in RCA: 25] [Impact Index Per Article: 4.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/30/2018] [Revised: 07/13/2018] [Accepted: 07/17/2018] [Indexed: 01/01/2023]
|
29
|
Ni Y, Arts R, Merkx M. Ratiometric Bioluminescent Sensor Proteins Based on Intramolecular Split Luciferase Complementation. ACS Sens 2019; 4:20-25. [PMID: 30525479 PMCID: PMC6350203 DOI: 10.1021/acssensors.8b01381] [Citation(s) in RCA: 43] [Impact Index Per Article: 7.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/30/2023]
Abstract
Bioluminescent sensor proteins provide attractive tools for applications ranging from in vivo imaging to point-of-care testing. Here we introduce a new class of ratiometric bioluminescent sensor proteins that do not rely on direct modulation of BRET efficiency, but are based on competitive intramolecular complementation of split NanoLuc luciferase. Proof of concept for the feasibility of this sensor principle was provided by developing a blue-red light emitting sensor protein for the detection of anti-HIV1-p17 antibodies with a 500% change in emission ratio and a Kd of 10 pM. The new sensor design also improved the dynamic response of a sensor for the therapeutic antibody cetuximab 4-fold, allowing the direct quantification of this anti-EGFR antibody in undiluted blood plasma. The modular sensor architecture allows easy and systematic tuning of a sensor's dynamic range and should be generally applicable to allow rational engineering of bioluminescent sensor proteins.
Collapse
Affiliation(s)
- Yan Ni
- Laboratory of Chemical Biology and Institute for Complex Molecular Systems, Department of Biomedical Engineering, Eindhoven University of Technology, Den Dolech 2, 5612 AZ Eindhoven, The Netherlands
| | - Remco Arts
- Laboratory of Chemical Biology and Institute for Complex Molecular Systems, Department of Biomedical Engineering, Eindhoven University of Technology, Den Dolech 2, 5612 AZ Eindhoven, The Netherlands
| | - Maarten Merkx
- Laboratory of Chemical Biology and Institute for Complex Molecular Systems, Department of Biomedical Engineering, Eindhoven University of Technology, Den Dolech 2, 5612 AZ Eindhoven, The Netherlands
| |
Collapse
|
30
|
Affiliation(s)
- Simona Ranallo
- Department of Chemical Sciences and Technologies , University of Rome Tor Vergata , Via della Ricerca Scientifica 1 , 00133 Rome , Italy
| | - Alessandro Porchetta
- Department of Chemical Sciences and Technologies , University of Rome Tor Vergata , Via della Ricerca Scientifica 1 , 00133 Rome , Italy
| | - Francesco Ricci
- Department of Chemical Sciences and Technologies , University of Rome Tor Vergata , Via della Ricerca Scientifica 1 , 00133 Rome , Italy
| |
Collapse
|
31
|
Tenda K, van Gerven B, Arts R, Hiruta Y, Merkx M, Citterio D. Paper‐Based Antibody Detection Devices Using Bioluminescent BRET‐Switching Sensor Proteins. Angew Chem Int Ed Engl 2018. [DOI: 10.1002/ange.201808070] [Citation(s) in RCA: 16] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/22/2023]
Affiliation(s)
- Keisuke Tenda
- Department of Applied ChemistryKeio University 3-14-1 Hiyoshi Kohoku-ku 223-8522 Yokohama Japan
| | - Benice van Gerven
- Department of Biomedical Engineering and Institute for Complex Molecular Systems (ICMS)Eindhoven University of Technology P.O. Box 513, 5600 MB Eindhoven The Netherlands
| | - Remco Arts
- Department of Biomedical Engineering and Institute for Complex Molecular Systems (ICMS)Eindhoven University of Technology P.O. Box 513, 5600 MB Eindhoven The Netherlands
| | - Yuki Hiruta
- Department of Applied ChemistryKeio University 3-14-1 Hiyoshi Kohoku-ku 223-8522 Yokohama Japan
| | - Maarten Merkx
- Department of Biomedical Engineering and Institute for Complex Molecular Systems (ICMS)Eindhoven University of Technology P.O. Box 513, 5600 MB Eindhoven The Netherlands
| | - Daniel Citterio
- Department of Applied ChemistryKeio University 3-14-1 Hiyoshi Kohoku-ku 223-8522 Yokohama Japan
| |
Collapse
|
32
|
Tenda K, van Gerven B, Arts R, Hiruta Y, Merkx M, Citterio D. Paper-Based Antibody Detection Devices Using Bioluminescent BRET-Switching Sensor Proteins. Angew Chem Int Ed Engl 2018; 57:15369-15373. [PMID: 30168634 PMCID: PMC6282528 DOI: 10.1002/anie.201808070] [Citation(s) in RCA: 98] [Impact Index Per Article: 14.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/15/2018] [Indexed: 12/04/2022]
Abstract
This work reports on fully integrated “sample‐in‐signal‐out” microfluidic paper‐based analytical devices (μPADs) relying on bioluminescence resonance energy transfer (BRET) switches for analyte recognition and colorimetric signal generation. The devices use BRET‐based antibody sensing proteins integrated into vertically assembled layers of functionalized paper, and their design enables sample volume‐independent and fully reagent‐free operation, including on‐device blood plasma separation. User operation is limited to the application of a single drop (20–30 μL) of sample (serum, whole blood) and the acquisition of a photograph 20 min after sample introduction, with no requirement for precise pipetting, liquid handling, or analytical equipment except for a camera. Simultaneous detection of three different antibodies (anti‐HIV1, anti‐HA, and anti‐DEN1) in whole blood was achieved. Given its simplicity, this type of device is ideally suited for user‐friendly point‐of‐care testing in low‐resource environments.
Collapse
Affiliation(s)
- Keisuke Tenda
- Department of Applied Chemistry, Keio University, 3-14-1 Hiyoshi, Kohoku-ku, 223-8522, Yokohama, Japan
| | - Benice van Gerven
- Department of Biomedical Engineering and Institute for Complex Molecular Systems (ICMS), Eindhoven University of Technology, P.O. Box 513, 5600, MB, Eindhoven, The Netherlands
| | - Remco Arts
- Department of Biomedical Engineering and Institute for Complex Molecular Systems (ICMS), Eindhoven University of Technology, P.O. Box 513, 5600, MB, Eindhoven, The Netherlands
| | - Yuki Hiruta
- Department of Applied Chemistry, Keio University, 3-14-1 Hiyoshi, Kohoku-ku, 223-8522, Yokohama, Japan
| | - Maarten Merkx
- Department of Biomedical Engineering and Institute for Complex Molecular Systems (ICMS), Eindhoven University of Technology, P.O. Box 513, 5600, MB, Eindhoven, The Netherlands
| | - Daniel Citterio
- Department of Applied Chemistry, Keio University, 3-14-1 Hiyoshi, Kohoku-ku, 223-8522, Yokohama, Japan
| |
Collapse
|
33
|
Li Y, Yang P, Lei N, Ma Y, Ji Y, Zhu C, Wu Y. Assembly of DNA-Templated Bioluminescent Modules for Amplified Detection of Protein Biomarkers. Anal Chem 2018; 90:11495-11502. [DOI: 10.1021/acs.analchem.8b02734] [Citation(s) in RCA: 12] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/03/2023]
Affiliation(s)
| | | | | | | | - Yaoting Ji
- Key Lab for Oral Biomedical Engineering of Ministry of Education, School and Hospital of Stomatology, Wuhan University, Wuhan, 430079, P. R. China
| | | | | |
Collapse
|
34
|
Yan X, Le XC, Zhang H. Antibody-Bridged Beacon for Homogeneous Detection of Small Molecules. Anal Chem 2018; 90:9667-9672. [DOI: 10.1021/acs.analchem.8b02510] [Citation(s) in RCA: 14] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/16/2022]
Affiliation(s)
- Xiaowen Yan
- Division of Analytical and Environmental Toxicology, Department of Laboratory Medicine and Pathology, University of Alberta, Edmonton, Alberta T6G 2G3, Canada
| | - X. Chris Le
- Division of Analytical and Environmental Toxicology, Department of Laboratory Medicine and Pathology, University of Alberta, Edmonton, Alberta T6G 2G3, Canada
| | - Hongquan Zhang
- Division of Analytical and Environmental Toxicology, Department of Laboratory Medicine and Pathology, University of Alberta, Edmonton, Alberta T6G 2G3, Canada
| |
Collapse
|
35
|
van Rosmalen M, Ni Y, Vervoort DFM, Arts R, Ludwig SKJ, Merkx M. Dual-Color Bioluminescent Sensor Proteins for Therapeutic Drug Monitoring of Antitumor Antibodies. Anal Chem 2018; 90:3592-3599. [PMID: 29443503 PMCID: PMC5843950 DOI: 10.1021/acs.analchem.8b00041] [Citation(s) in RCA: 39] [Impact Index Per Article: 5.6] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/21/2022]
Abstract
Monitoring the levels of therapeutic antibodies in individual patients would allow patient-specific dose optimization, with the potential for major therapeutic and financial benefits. Our group recently developed a new platform of bioluminescent sensor proteins (LUMABS; LUMinescent AntiBody Sensor) that allow antibody detection directly in blood plasma. In this study, we targeted four clinically important therapeutic antibodies, the Her2-receptor targeting trastuzumab, the anti-CD20 antibodies rituximab and obinutuzumab, and the EGFR-blocking cetuximab. A strong correlation was found between the affinity of the antibody binding peptide and sensor performance. LUMABS sensors with physiologically relevant affinities and decent sensor responses were obtained for trastuzumab and cetuximab using mimotope and meditope peptides, respectively, with affinities in the 10-7 M range. The lower affinity of the CD20-derived cyclic peptide employed in the anti-CD20 LUMABS sensor ( Kd = 10-5 M), translated in a LUMABS sensor with a strongly attenuated sensor response. The trastuzumab and cetuximab sensors were further characterized with respect to binding kinetics and their performance in undiluted blood plasma. For both antibodies, LUMABS-based detection directly in plasma compared well to the analytical performance of commercial ELISA kits. Besides identifying important design parameters for the development of new LUMABS sensors, this work demonstrates the potential of the LUMABS platform for point-of-care detection of therapeutic antibodies.
Collapse
Affiliation(s)
- Martijn van Rosmalen
- Laboratory of Chemical Biology and Institute for Complex Molecular Systems (ICMS), Department of Biomedical Engineering , Eindhoven University of Technology , P.O. Box 513, 5600 MB Eindhoven , The Netherlands
| | - Yan Ni
- Laboratory of Chemical Biology and Institute for Complex Molecular Systems (ICMS), Department of Biomedical Engineering , Eindhoven University of Technology , P.O. Box 513, 5600 MB Eindhoven , The Netherlands
| | - Daan F M Vervoort
- Laboratory of Chemical Biology and Institute for Complex Molecular Systems (ICMS), Department of Biomedical Engineering , Eindhoven University of Technology , P.O. Box 513, 5600 MB Eindhoven , The Netherlands
| | - Remco Arts
- Laboratory of Chemical Biology and Institute for Complex Molecular Systems (ICMS), Department of Biomedical Engineering , Eindhoven University of Technology , P.O. Box 513, 5600 MB Eindhoven , The Netherlands
| | - Susann K J Ludwig
- Laboratory of Chemical Biology and Institute for Complex Molecular Systems (ICMS), Department of Biomedical Engineering , Eindhoven University of Technology , P.O. Box 513, 5600 MB Eindhoven , The Netherlands
| | - Maarten Merkx
- Laboratory of Chemical Biology and Institute for Complex Molecular Systems (ICMS), Department of Biomedical Engineering , Eindhoven University of Technology , P.O. Box 513, 5600 MB Eindhoven , The Netherlands
| |
Collapse
|