1
|
Su D, Ben W, Strobel BW, Qiang Z. Impacts of chlorine disinfection of municipal sewage effluent on receiving rivers: Changes in organic matter and microbial communities. JOURNAL OF HAZARDOUS MATERIALS 2025; 492:138232. [PMID: 40233458 DOI: 10.1016/j.jhazmat.2025.138232] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 01/24/2025] [Revised: 03/11/2025] [Accepted: 04/08/2025] [Indexed: 04/17/2025]
Abstract
Effluents from wastewater treatment plants (WWTPs) can impact various aspects of receiving aquatic ecosystems, yet the specific effects of chlorine disinfection of effluents on these ecosystems remain poorly understood. In this study, a simulated flow-through channel system was employed to evaluate the changes in water quality and microbial community in receiving rivers resulting from the discharge of WWTP effluent, with or without chlorination. Results showed that dissolved organic matter (DOM) in secondary effluent from WWTPs exhibited higher fluorescence intensity and elevated levels of biopolymers, humic acids, and low molecular weight compounds compared to river water. Microbial analysis revealed that the input of secondary effluent promoted the proliferation of diverse microbial communities in periphyton of the receiving water, while the chlorinated effluents selectively inhibited chlorine-sensitive taxa in periphyton and favored chlorine-tolerant ones. Chlorine disinfection effectively reduced most pathogens in effluents; however, certain genera, such as Neisseriaceae and Escherichia-Shigella, persisted. Moreover, exposure to chlorinated effluent significantly elevated the relative abundance of Pseudomonas in periphyton compared to other conditions, raising concerns about the persistence of chlorine-tolerant pathogens in aquatic environments. These findings highlight the critical need to further evaluate the impact of the disinfection process in WWTPs on the long-term health and stability of riverine ecosystems.
Collapse
Affiliation(s)
- Du Su
- Research Center for Marine Science, Hebei Normal University of Science and Technology, Qinhuangdao 066004, China; Hebei Key Laboratory of Ocean Dynamics, Resources and Environments, Qinhuangdao 066000, China; Research Center for Eco-Environmental Sciences, Chinese Academy of Sciences, 18 Shuang-qing Road, Beijing 100085, China
| | - Weiwei Ben
- Research Center for Eco-Environmental Sciences, Chinese Academy of Sciences, 18 Shuang-qing Road, Beijing 100085, China.
| | - Bjarne W Strobel
- Department of Plant and Environmental Sciences, University of Copenhagen, Thorvaldsensvej 40, Frederiksberg C DK-1871, Denmark
| | - Zhimin Qiang
- School of Environmental Science and Engineering, Shanghai Jiao Tong University, Shanghai 200240, China.
| |
Collapse
|
2
|
Wu G, Zhang H, Huang T, Song Y, Liu X, Liu X, Wang X, Pei T, Xu G, Wang Z. Hydraulic and thermal performance trigger the deterministic assembly of water microbiomes: From biogeographical homogenization to machine learning model. WATER RESEARCH 2025; 282:123626. [PMID: 40262432 DOI: 10.1016/j.watres.2025.123626] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 01/23/2025] [Revised: 04/03/2025] [Accepted: 04/09/2025] [Indexed: 04/24/2025]
Abstract
Water quality at the point of consumption has long been a health issue because of the potential for microbial ecology. However, research on water hydraulic performance remains in its infancy, and in particular, little is known about the effects of thermal performance during winter. This study explored the effects of stagnation and municipal heating on microbial communities in tap water, focusing on spatial and temporal variations in microbial community composition. The results revealed that stagnation significantly alters the microbial community, especially in heating areas, where the temperature exacerbates microbial growth. Furthermore, hydraulic and thermal performance drive deterministic assembly processes in microbial communities, as evidenced by the reductions in β-diversity, normalized stochasticity ratio (NST), and neutral community model (NCM) fit. Machine learning models revealed that stagnation time greater than 8 h results in increased community abundance because of longer exposure to organic matter and nutrients. The study finding illustrate the importance of environmental influences on microbial community dynamics, and provide valuable insights into the water microbial community, particularly in areas with prolonged stagnation.
Collapse
Affiliation(s)
- Guilin Wu
- Collaborative Innovation Center of Water Pollution Control and Water Quality Security Assurance of Shaanxi Province, Xi'an University of Architecture and Technology, Xi'an, China; Shaanxi Provincial Field Scientific Observation and Research Station of Water Quality in Qinling Mountain, Xi'an University of Architecture and Technology, Xi'an, China; Shaanxi Key Laboratory of Environmental Engineering, Xi'an University of Architecture and Technology, Xi'an, China
| | - Haihan Zhang
- Collaborative Innovation Center of Water Pollution Control and Water Quality Security Assurance of Shaanxi Province, Xi'an University of Architecture and Technology, Xi'an, China; Shaanxi Provincial Field Scientific Observation and Research Station of Water Quality in Qinling Mountain, Xi'an University of Architecture and Technology, Xi'an, China; Shaanxi Key Laboratory of Environmental Engineering, Xi'an University of Architecture and Technology, Xi'an, China.
| | - Tinglin Huang
- Collaborative Innovation Center of Water Pollution Control and Water Quality Security Assurance of Shaanxi Province, Xi'an University of Architecture and Technology, Xi'an, China; Shaanxi Provincial Field Scientific Observation and Research Station of Water Quality in Qinling Mountain, Xi'an University of Architecture and Technology, Xi'an, China; Shaanxi Key Laboratory of Environmental Engineering, Xi'an University of Architecture and Technology, Xi'an, China
| | - Yutong Song
- School of Future Technology, Xi'an University of Architecture and Technology, Xi'an, China
| | - Xiang Liu
- Collaborative Innovation Center of Water Pollution Control and Water Quality Security Assurance of Shaanxi Province, Xi'an University of Architecture and Technology, Xi'an, China; Shaanxi Provincial Field Scientific Observation and Research Station of Water Quality in Qinling Mountain, Xi'an University of Architecture and Technology, Xi'an, China; Shaanxi Key Laboratory of Environmental Engineering, Xi'an University of Architecture and Technology, Xi'an, China
| | - Xiaoyan Liu
- Collaborative Innovation Center of Water Pollution Control and Water Quality Security Assurance of Shaanxi Province, Xi'an University of Architecture and Technology, Xi'an, China; Shaanxi Provincial Field Scientific Observation and Research Station of Water Quality in Qinling Mountain, Xi'an University of Architecture and Technology, Xi'an, China; Shaanxi Key Laboratory of Environmental Engineering, Xi'an University of Architecture and Technology, Xi'an, China
| | - Xiaolong Wang
- Collaborative Innovation Center of Water Pollution Control and Water Quality Security Assurance of Shaanxi Province, Xi'an University of Architecture and Technology, Xi'an, China; Shaanxi Provincial Field Scientific Observation and Research Station of Water Quality in Qinling Mountain, Xi'an University of Architecture and Technology, Xi'an, China; Shaanxi Key Laboratory of Environmental Engineering, Xi'an University of Architecture and Technology, Xi'an, China
| | - Tingting Pei
- Collaborative Innovation Center of Water Pollution Control and Water Quality Security Assurance of Shaanxi Province, Xi'an University of Architecture and Technology, Xi'an, China; Shaanxi Provincial Field Scientific Observation and Research Station of Water Quality in Qinling Mountain, Xi'an University of Architecture and Technology, Xi'an, China; Shaanxi Key Laboratory of Environmental Engineering, Xi'an University of Architecture and Technology, Xi'an, China
| | - Guojia Xu
- Collaborative Innovation Center of Water Pollution Control and Water Quality Security Assurance of Shaanxi Province, Xi'an University of Architecture and Technology, Xi'an, China; Shaanxi Provincial Field Scientific Observation and Research Station of Water Quality in Qinling Mountain, Xi'an University of Architecture and Technology, Xi'an, China; Shaanxi Key Laboratory of Environmental Engineering, Xi'an University of Architecture and Technology, Xi'an, China
| | - Zhihan Wang
- Collaborative Innovation Center of Water Pollution Control and Water Quality Security Assurance of Shaanxi Province, Xi'an University of Architecture and Technology, Xi'an, China; Shaanxi Provincial Field Scientific Observation and Research Station of Water Quality in Qinling Mountain, Xi'an University of Architecture and Technology, Xi'an, China; Shaanxi Key Laboratory of Environmental Engineering, Xi'an University of Architecture and Technology, Xi'an, China
| |
Collapse
|
3
|
Yan J, Zhang X, Shi X, Wu J, Zhou Z, Tang Y, Bao Z, Luo N, Zhang D, Chen J, Zhang H. Metagenomic insights into the rapid recovery mechanisms of prokaryotic community and spread of antibiotic resistance genes after seawater disinfection. WATER RESEARCH 2025; 271:122887. [PMID: 39637691 DOI: 10.1016/j.watres.2024.122887] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 04/16/2024] [Revised: 10/26/2024] [Accepted: 11/28/2024] [Indexed: 12/07/2024]
Abstract
Disinfectants, such as bleaching powder, are widely employed in marine aquaculture worldwide to control the bacterial pathogens and eliminate antibiotic resistance genes (ARGs). Nevertheless, the rapid recovery of prokaryotic community compositions (PCCs) after disinfection may significantly influence the overall efficacy of disinfection. Presently, little is known about the rapid recovery mechanisms of PCCs and its impact on the removal of ARGs in seawater. In this study, 16S rRNA gene sequencing and metagenomic analysis were used to address the above concerns through simulating the disinfection process in aquaculture. The results showed that recovery of PCCs began within 16 h. The underlying mechanisms of the rapid recovery of PCCs were the synergistic interactions between microbes and the residues of disinfection-resistant bacteria (DRB). Disinfection resistance genes (DRGs) related to efflux pump serve as the primary molecular foundation providing DRB to resist disinfection. Among the 78 annotated ARGs, only 10 ARGs exhibited a significant decrease (P < 0.05) after 72 h, implying the ineffective removal of ARGs by bleaching powder. Furthermore, bacterial co-resistance to disinfectants and antibiotics was observed. Genome analysis of two highly resistant DRB from Pseudomonadaceae revealed that both DRB carried 16 DRGs, aiding the recovery of PCCs and the spread of ARGs. These findings provide novel insights in the mechanisms of the rapid recovery of PCCs and bacterial co-resistance to disinfectants and antibiotics, which can be crucial for the management of pathogens and antibiotic resistance in seawater.
Collapse
Affiliation(s)
- Jiaojiao Yan
- State Key Laboratory for Managing Biotic and Chemical Threats to the Quality and Safety of Agro-products, Ningbo University, Ningbo, 315211, China; Shanghai Treatgut Biotechnology Co., Ltd., Shanghai, 200441, China; Key Laboratory of Aquacultural Biotechnology, Ministry of Education, School of Marine Sciences, Ningbo University, Ningbo, 315211, China
| | - Xinxu Zhang
- Archaeal Biology Center, Synthetic Biology Research Center, Shenzhen Key Laboratory of Marine Microbiome Engineering, Key Laboratory of Marine Microbiome Engineering of Guangdong Higher Education Institutes, Institute for Advanced Study, Shenzhen University, Shenzhen, 518060, China; Key Laboratory of Aquacultural Biotechnology, Ministry of Education, School of Marine Sciences, Ningbo University, Ningbo, 315211, China
| | - Xinyong Shi
- State Key Laboratory for Managing Biotic and Chemical Threats to the Quality and Safety of Agro-products, Ningbo University, Ningbo, 315211, China; Key Laboratory of Aquacultural Biotechnology, Ministry of Education, School of Marine Sciences, Ningbo University, Ningbo, 315211, China
| | - Jialin Wu
- Ningbo Haiwei Ecological Technology Co., Ltd., Ningbo, 315141, China
| | - Ziang Zhou
- State Key Laboratory for Managing Biotic and Chemical Threats to the Quality and Safety of Agro-products, Ningbo University, Ningbo, 315211, China; Key Laboratory of Aquacultural Biotechnology, Ministry of Education, School of Marine Sciences, Ningbo University, Ningbo, 315211, China
| | - Yawen Tang
- State Key Laboratory for Managing Biotic and Chemical Threats to the Quality and Safety of Agro-products, Ningbo University, Ningbo, 315211, China; Key Laboratory of Aquacultural Biotechnology, Ministry of Education, School of Marine Sciences, Ningbo University, Ningbo, 315211, China
| | - Zhen Bao
- State Key Laboratory for Managing Biotic and Chemical Threats to the Quality and Safety of Agro-products, Ningbo University, Ningbo, 315211, China; Key Laboratory of Aquacultural Biotechnology, Ministry of Education, School of Marine Sciences, Ningbo University, Ningbo, 315211, China
| | - Nan Luo
- State Key Laboratory for Managing Biotic and Chemical Threats to the Quality and Safety of Agro-products, Ningbo University, Ningbo, 315211, China; Key Laboratory of Aquacultural Biotechnology, Ministry of Education, School of Marine Sciences, Ningbo University, Ningbo, 315211, China
| | - Demin Zhang
- State Key Laboratory for Managing Biotic and Chemical Threats to the Quality and Safety of Agro-products, Ningbo University, Ningbo, 315211, China; Key Laboratory of Aquacultural Biotechnology, Ministry of Education, School of Marine Sciences, Ningbo University, Ningbo, 315211, China.
| | - Jiong Chen
- State Key Laboratory for Managing Biotic and Chemical Threats to the Quality and Safety of Agro-products, Ningbo University, Ningbo, 315211, China; Key Laboratory of Aquacultural Biotechnology, Ministry of Education, School of Marine Sciences, Ningbo University, Ningbo, 315211, China
| | - Huajun Zhang
- State Key Laboratory for Managing Biotic and Chemical Threats to the Quality and Safety of Agro-products, Ningbo University, Ningbo, 315211, China; Marine Economic Research Center, Donghai Academy, Ningbo University, Ningbo, 315211, China; Key Laboratory of Aquacultural Biotechnology, Ministry of Education, School of Marine Sciences, Ningbo University, Ningbo, 315211, China.
| |
Collapse
|
4
|
Xue Z, He H, Han Y, Tian W, Li S, Guo J, Yu P, Qiao L, Zhang W. Relic DNA obscures bacterial diversity and interactions in ballast tank sediment. ENVIRONMENTAL RESEARCH 2025; 267:120715. [PMID: 39733986 DOI: 10.1016/j.envres.2024.120715] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 11/05/2024] [Revised: 12/24/2024] [Accepted: 12/27/2024] [Indexed: 12/31/2024]
Abstract
The dark and anoxic environment of ballast tank sediment (BTS) harbors substantial amounts of relic DNA, yet its impact on microbial diversity estimates in BTS management remains poorly understood. This study employed propidium monoazide (PMA) treatment to eliminate relic DNA and used 16S amplicon high-throughput sequencing to characterize both total and viable bacteria. Our findings revealed that relic DNA is abundant in BTS. When removed, it led to variable reductions in species richness, which fluctuated from a 3.15% increase to a 37.52% decrease. Additionally, 6.27%-15.79% of OTUs were absent in the PMA-treated samples. These findings indicate that relic DNA has diverse effects on microbial diversity estimates. Moreover, relic DNA removal altered the relative abundances of a wide range of taxa, thereby facilitating the detection of rare taxa. Furthermore, the absence of relic DNA resulted in an overestimation of co-occurrence network size, complexity, and competitiveness, which could lead to misinterpretations of community assembly processes. In conclusion, our findings indicate that relic DNA obscures microbial diversity estimates and risk assessments in BTS, highlighting the critical need for monitoring viable bacteria in ballast sediment management.
Collapse
Affiliation(s)
- Zhaozhao Xue
- Marine College, Shandong University, Weihai, China
| | - Haoze He
- Marine College, Shandong University, Weihai, China
| | - Yangchun Han
- Integrated Technical Service Center of Jiangyin Customs, Jiangyin, China
| | - Wen Tian
- Animal, Plant and Food Inspection Center of Nanjing Customs District, Nanjing, China
| | - Shengjie Li
- COSCO SHIPPING Heavy Industry Technology (Weihai) Co., Ltd, Weihai, China
| | - Jingfeng Guo
- Integrated Technical Service Center of Jiangyin Customs, Jiangyin, China
| | - Pei Yu
- Marine College, Shandong University, Weihai, China
| | - Lina Qiao
- Marine College, Shandong University, Weihai, China
| | - Wei Zhang
- Marine College, Shandong University, Weihai, China.
| |
Collapse
|
5
|
Ditommaso S, Garlasco J, Memoli G, Curtoni A, Bondi A, Ceccarelli A, Giacomuzzi M. Emergence of Mycobacterium gordonae in heater-cooler units: a five-year prospective surveillance of devices frequently subjected to chloramine-T booster disinfection. J Hosp Infect 2025; 155:9-16. [PMID: 39447649 DOI: 10.1016/j.jhin.2024.10.006] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/26/2024] [Revised: 09/13/2024] [Accepted: 10/04/2024] [Indexed: 10/26/2024]
Abstract
BACKGROUND Worldwide, the detection of Mycobacterium chimaera in LivaNova heater-cooler units (HCUs) has led to their replacement with other HCUs, although non-tuberculous mycobacteria (NTM) have been reported also for HCUs produced by other manufacturers. In almost all hospitals of our region, LivaNova HCUs have been replaced with Maquet HCU40s, regularly disinfected with chloramine-T. AIM To report the results of the surveillance over a 63-month operation period of the Maquet devices, and to provide a trend in NTM positivity over time. METHODS Twenty-nine Maquet devices (HCU40 and HU35) were monitored by two culture methods and propidium monoazide polymerase chain reaction (PMA-PCR) method. The trend in NTM positivity rate was evaluated through the Locally Estimated Scatterplot Smoothing regression and then modelled over time through segmented logistic regression. FINDINGS The data acquired during the study period demonstrate a remarkable increase in the positivity rate, especially after the third year (maximum slope change at 1280 days). Non-tuberculous mycobacteria were isolated in 150 water samples (37.2%); 100% and 62% of HCU40 and HU35 devices, respectively, were colonized with non-tuberculous mycobacteria. The most frequently detected species were Mycobacterium gordonae (73%) followed by Mycobacterium chelonae (41%) and Mycobacterium paragordonae (11%). CONCLUSION Preventive strategies by disinfection with chloramine-T did not effectively reduce non-tuberculous mycobacteria colonization of Maquet devices. Although, to date, no cases of postoperative invasive infections linked to Maquet devices have been reported, our microbiological results emphasize the need for (1) designing changes to increase safety of devices and (2) researching and developing new disinfection protocols including alternative molecules.
Collapse
Affiliation(s)
- S Ditommaso
- Department of Public Health and Pediatrics, University of Turin, Turin, Italy.
| | - J Garlasco
- Department of Public Health and Pediatrics, University of Turin, Turin, Italy
| | - G Memoli
- Department of Public Health and Pediatrics, University of Turin, Turin, Italy
| | - A Curtoni
- Department of Public Health and Pediatrics, University of Turin, Turin, Italy; Microbiology and Virology Unit, University Hospital Città della Salute e della Scienza di Torino, Turin, Italy
| | - A Bondi
- Department of Public Health and Pediatrics, University of Turin, Turin, Italy; Microbiology and Virology Unit, University Hospital Città della Salute e della Scienza di Torino, Turin, Italy
| | - A Ceccarelli
- Department of Clinical and Biological Sciences, University of Turin, S. Luigi Hospital, Orbassano, Italy
| | - M Giacomuzzi
- Department of Public Health and Pediatrics, University of Turin, Turin, Italy
| |
Collapse
|
6
|
Kim T, Zhao X, Hozalski RM, LaPara TM. Residual disinfectant effectively suppresses Legionella species in drinking water distribution systems supplied by surface water in Minnesota, USA. THE SCIENCE OF THE TOTAL ENVIRONMENT 2024; 940:173317. [PMID: 38788954 DOI: 10.1016/j.scitotenv.2024.173317] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 10/19/2023] [Revised: 05/10/2024] [Accepted: 05/15/2024] [Indexed: 05/26/2024]
Abstract
Seven public water systems in Minnesota, USA were analyzed from one to five times over a two-year period to assess temporal changes in the concentrations of total bacteria, Legionella spp., and Legionella pneumophila from source (i.e., raw water) through the water treatment process to the end water user. Bacterial biomass was collected by filtering large volumes of raw water (12 to 425 L, median: 38 L) or finished and tap water (27 to 1205 L, median: 448 L) using ultrafiltration membrane modules. Quantitative PCR (qPCR) was then used to enumerate all bacteria (16S rRNA gene fragments), all Legionella spp. (ssrA), and Legionella pneumophila (mip). Total coliforms, Escherichia coli, and L. pneumophila also were quantified in the water samples via cultivation. Median concentrations of total bacteria and Legionella spp. (ssrA) in raw water (8.5 and 4.3 log copies/L, respectively) decreased by about 2 log units during water treatment. The concentration of Legionella spp. (ssrA) in water collected from distribution systems inversely correlated with the total chlorine concentration for chloraminated systems significantly (p = 0.03). Although only 8 samples were collected from drinking water distribution systems using free chlorine as a residual disinfectant, these samples had significantly lower concentrations of Legionella spp. (ssrA) than samples collected from the chloraminated systems (p = 5 × 10-4). There was considerable incongruity between the results obtained via cultivation-independent (qPCR) and cultivation-dependent assays. Numerous samples were positive for L. pneumophila via cultivation, none of which tested positive for L. pneumophilia (mip) via qPCR. Conversely, a single sample tested positive for L. pneumophilia (mip) via qPCR, but this sample tested negative for L. pneumophilia via cultivation. Overall, the results suggest that conventional treatment is effective at reducing, but not eliminating, Legionella spp. from surface water supplies and that residual disinfection is effective at suppressing these organisms within drinking water distribution systems.
Collapse
Affiliation(s)
- Taegyu Kim
- Department of Civil, Environmental, and Geo-Engineering, University of Minnesota Twin-Cities, 500 Pillsbury Drive S.E., Minneapolis, MN, USA
| | - Xiaotian Zhao
- Department of Civil, Environmental, and Geo-Engineering, University of Minnesota Twin-Cities, 500 Pillsbury Drive S.E., Minneapolis, MN, USA
| | - Raymond M Hozalski
- Department of Civil, Environmental, and Geo-Engineering, University of Minnesota Twin-Cities, 500 Pillsbury Drive S.E., Minneapolis, MN, USA; Biotechnology Institute, University of Minnesota Twin Cities, 1479 Gortner Ave, St. Paul, MN, USA
| | - Timothy M LaPara
- Department of Civil, Environmental, and Geo-Engineering, University of Minnesota Twin-Cities, 500 Pillsbury Drive S.E., Minneapolis, MN, USA; Biotechnology Institute, University of Minnesota Twin Cities, 1479 Gortner Ave, St. Paul, MN, USA.
| |
Collapse
|
7
|
Liu J, Zhao R, Feng J, Fu W, Cao L, Zhang J, Lei Y, Liang J, Lin L, Li X, Li B. Bacterial assembly and succession patterns in conventional and advanced drinking water systems: From source to tap. JOURNAL OF HAZARDOUS MATERIALS 2024; 473:134613. [PMID: 38788571 DOI: 10.1016/j.jhazmat.2024.134613] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 01/22/2024] [Revised: 05/01/2024] [Accepted: 05/11/2024] [Indexed: 05/26/2024]
Abstract
Bacteria are pivotal to drinking water treatment and public health. However, the mechanisms of bacterial assembly and their impact on species coexistence remain largely unexplored. This study explored the assembly and succession of bacterial communities in two full-scale drinking water systems over one year. We observed a decline in bacterial biomass, diversity, and co-occurrence network complexity along the treatment processes, except for the biological activated carbon filtration stage. The conventional plant showed higher bacterial diversity than the advanced plant, despite similar bacterial concentrations and better removal efficiency. The biological activated carbon filter exhibited high phylogenetic diversity, indicating enhanced bacterial metabolic functionality for organic matter removal. Chlorination inactivated most bacteria but favored some chlorination-resistant and potentially pathogenic species, such as Burkholderia, Bosea, Brevundimonas, and Acinetobacter. Moreover, the spatiotemporal dynamics of the bacterial continuum were primarily driven by stochastic processes, explaining more than 78% of the relative importance. The advanced plant's bacterial community was less influenced by dispersal limitation and more by homogeneous selection. The stochastic process regulated bacterial diversity and influenced the complexity of the species co-occurrence network. These findings deepen our understanding of microbial ecological mechanisms and species interactions, offering insights for enhancing hygienic safety in drinking water systems.
Collapse
Affiliation(s)
- Jie Liu
- State Environmental Protection Key Laboratory of Microorganism Application and Risk Control, Tsinghua Shenzhen International Graduate School, Tsinghua University, Shenzhen, China; State Key Laboratory of Herbage Improvement and Grassland Agro-ecosystems, Center for Grassland Microbiome, College of Pastoral Agriculture Science and Technology, Lanzhou University, Lanzhou, China
| | - Renxin Zhao
- State Environmental Protection Key Laboratory of Microorganism Application and Risk Control, Tsinghua Shenzhen International Graduate School, Tsinghua University, Shenzhen, China; School of Ecology and Environment, Inner Mongolia University, Hohhot, China
| | - Jie Feng
- State Environmental Protection Key Laboratory of Microorganism Application and Risk Control, Tsinghua Shenzhen International Graduate School, Tsinghua University, Shenzhen, China
| | - Wenjie Fu
- State Environmental Protection Key Laboratory of Microorganism Application and Risk Control, Tsinghua Shenzhen International Graduate School, Tsinghua University, Shenzhen, China
| | - Lijia Cao
- State Environmental Protection Key Laboratory of Microorganism Application and Risk Control, Tsinghua Shenzhen International Graduate School, Tsinghua University, Shenzhen, China
| | - Jiayu Zhang
- State Environmental Protection Key Laboratory of Microorganism Application and Risk Control, Tsinghua Shenzhen International Graduate School, Tsinghua University, Shenzhen, China
| | - Yusha Lei
- State Environmental Protection Key Laboratory of Microorganism Application and Risk Control, Tsinghua Shenzhen International Graduate School, Tsinghua University, Shenzhen, China
| | - Jiajin Liang
- State Environmental Protection Key Laboratory of Microorganism Application and Risk Control, Tsinghua Shenzhen International Graduate School, Tsinghua University, Shenzhen, China
| | - Lin Lin
- State Environmental Protection Key Laboratory of Microorganism Application and Risk Control, Tsinghua Shenzhen International Graduate School, Tsinghua University, Shenzhen, China
| | - Xiaoyan Li
- State Environmental Protection Key Laboratory of Microorganism Application and Risk Control, Tsinghua Shenzhen International Graduate School, Tsinghua University, Shenzhen, China
| | - Bing Li
- State Environmental Protection Key Laboratory of Microorganism Application and Risk Control, Tsinghua Shenzhen International Graduate School, Tsinghua University, Shenzhen, China.
| |
Collapse
|
8
|
Maranha A, Alarico S, Nunes-Costa D, Melo-Marques I, Roxo I, Castanheira P, Caramelo O, Empadinhas N. Drinking Water Microbiota, Entero-Mammary Pathways, and Breast Cancer: Focus on Nontuberculous Mycobacteria. Microorganisms 2024; 12:1425. [PMID: 39065193 PMCID: PMC11279143 DOI: 10.3390/microorganisms12071425] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/29/2024] [Revised: 07/03/2024] [Accepted: 07/09/2024] [Indexed: 07/28/2024] Open
Abstract
The prospect of drinking water serving as a conduit for gut bacteria, artificially selected by disinfection strategies and a lack of monitoring at the point of use, is concerning. Certain opportunistic pathogens, notably some nontuberculous mycobacteria (NTM), often exceed coliform bacteria levels in drinking water, posing safety risks. NTM and other microbiota resist chlorination and thrive in plumbing systems. When inhaled, opportunistic NTM can infect the lungs of immunocompromised or chronically ill patients and the elderly, primarily postmenopausal women. When ingested with drinking water, NTM often survive stomach acidity, reach the intestines, and migrate to other organs using immune cells as vehicles, potentially colonizing tumor tissue, including in breast cancer. The link between the microbiome and cancer is not new, yet the recognition of intratumoral microbiomes is a recent development. Breast cancer risk rises with age, and NTM infections have emerged as a concern among breast cancer patients. In addition to studies hinting at a potential association between chronic NTM infections and lung cancer, NTM have also been detected in breast tumors at levels higher than normal adjacent tissue. Evaluating the risks of continued ingestion of contaminated drinking water is paramount, especially given the ability of various bacteria to migrate from the gut to breast tissue via entero-mammary pathways. This underscores a pressing need to revise water safety monitoring guidelines and delve into hormonal factors, including addressing the disproportionate impact of NTM infections and breast cancer on women and examining the potential health risks posed by the cryptic and unchecked microbiota from drinking water.
Collapse
Affiliation(s)
- Ana Maranha
- Center for Neuroscience and Cell Biology (CNC-UC), University of Coimbra, 3004-504 Coimbra, Portugal; (A.M.); (S.A.); (D.N.-C.); (I.M.-M.); (I.R.)
- Centre for Innovative Biomedicine & Biotechnology (CIBB), University of Coimbra, 3004-504 Coimbra, Portugal
| | - Susana Alarico
- Center for Neuroscience and Cell Biology (CNC-UC), University of Coimbra, 3004-504 Coimbra, Portugal; (A.M.); (S.A.); (D.N.-C.); (I.M.-M.); (I.R.)
- Centre for Innovative Biomedicine & Biotechnology (CIBB), University of Coimbra, 3004-504 Coimbra, Portugal
| | - Daniela Nunes-Costa
- Center for Neuroscience and Cell Biology (CNC-UC), University of Coimbra, 3004-504 Coimbra, Portugal; (A.M.); (S.A.); (D.N.-C.); (I.M.-M.); (I.R.)
- Centre for Innovative Biomedicine & Biotechnology (CIBB), University of Coimbra, 3004-504 Coimbra, Portugal
| | - Inês Melo-Marques
- Center for Neuroscience and Cell Biology (CNC-UC), University of Coimbra, 3004-504 Coimbra, Portugal; (A.M.); (S.A.); (D.N.-C.); (I.M.-M.); (I.R.)
- Centre for Innovative Biomedicine & Biotechnology (CIBB), University of Coimbra, 3004-504 Coimbra, Portugal
| | - Inês Roxo
- Center for Neuroscience and Cell Biology (CNC-UC), University of Coimbra, 3004-504 Coimbra, Portugal; (A.M.); (S.A.); (D.N.-C.); (I.M.-M.); (I.R.)
- Centre for Innovative Biomedicine & Biotechnology (CIBB), University of Coimbra, 3004-504 Coimbra, Portugal
- Ph.D. Programme in Biomedicine and Experimental Biology (PDBEB), Institute for Interdisciplinary Research, University of Coimbra, 3004-504 Coimbra, Portugal
| | | | - Olga Caramelo
- Gynecology Department, Coimbra Hospital and University Centre (CHUC), 3004-561 Coimbra, Portugal;
| | - Nuno Empadinhas
- Center for Neuroscience and Cell Biology (CNC-UC), University of Coimbra, 3004-504 Coimbra, Portugal; (A.M.); (S.A.); (D.N.-C.); (I.M.-M.); (I.R.)
- Centre for Innovative Biomedicine & Biotechnology (CIBB), University of Coimbra, 3004-504 Coimbra, Portugal
| |
Collapse
|
9
|
Kalu CM, Mudau KL, Masindi V, Ijoma GN, Tekere M. Occurrences and implications of pathogenic and antibiotic-resistant bacteria in different stages of drinking water treatment plants and distribution systems. Heliyon 2024; 10:e26380. [PMID: 38434035 PMCID: PMC10906316 DOI: 10.1016/j.heliyon.2024.e26380] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/01/2023] [Revised: 12/05/2023] [Accepted: 02/12/2024] [Indexed: 03/05/2024] Open
Abstract
Different stages of drinking water treatment plants (DWTPs) play specific roles in diverse contaminants' removal present in natural water sources. Although the stages are recorded to promote adequate treatment of water, the occurrence of pathogenic bacteria (PB) and antibiotic-resistant bacteria (ARB) in the treated water and the changes in their diversity and abundance as it passed down to the end users through the drinking water distribution systems (DWDSs), is a great concern, especially to human health. This could imply that the different stages and the distribution system provide a good microenvironment for their growth. Hence, it becomes pertinent to constantly monitor and document the diversity of PB and ARB present at each stage of the treatment and distribution system. This review aimed at documenting the occurrence of PB and ARB at different stages of treatment and distribution systems as well as the implication of their occurrence globally. An exhaustive literature search from Web of Science, Science-Direct database, Google Scholar, Academic Research Databases like the National Center for Biotechnology Information, Scopus, and SpringerLink was done. The obtained information showed that the different treatment stages and distribution systems influence the PB and ARB that proliferate. To minimize the human health risks associated with the occurrence of these PB, the present review, suggests the development of advanced technologies that can promote quick monitoring of PB/ARB at each treatment stage and distribution system as well as reduction of the cost of environomics analysis to promote better microbial analysis.
Collapse
Affiliation(s)
- Chimdi M. Kalu
- Department of Environmental Science, College of Agriculture and Environmental Sciences, University of South Africa, Florida, 1710, South Africa
| | - Khuthadzo L. Mudau
- Department of Environmental Science, College of Agriculture and Environmental Sciences, University of South Africa, Florida, 1710, South Africa
| | - Vhahangwele Masindi
- Department of Environmental Science, College of Agriculture and Environmental Sciences, University of South Africa, Florida, 1710, South Africa
- Magalies Water, Scientific Services, Research & Development Division, Brits, South Africa
| | - Grace N. Ijoma
- Department of Environmental Science, College of Agriculture and Environmental Sciences, University of South Africa, Florida, 1710, South Africa
| | - Memory Tekere
- Department of Environmental Science, College of Agriculture and Environmental Sciences, University of South Africa, Florida, 1710, South Africa
| |
Collapse
|
10
|
Lan W, Liu H, Weng R, Zeng Y, Lou J, Xu H, Yu Y, Jiang Y. Microbial community of municipal drinking water in Hangzhou using metagenomic sequencing. ENVIRONMENTAL POLLUTION (BARKING, ESSEX : 1987) 2024; 342:123066. [PMID: 38048871 DOI: 10.1016/j.envpol.2023.123066] [Citation(s) in RCA: 2] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 09/01/2023] [Revised: 11/01/2023] [Accepted: 11/27/2023] [Indexed: 12/06/2023]
Abstract
While traditional culture-dependent methods can effectively detect certain microorganisms, the comprehensive composition of the municipal drinking water (DW) microbiome, including bacteria, archaea, and viruses, remains unknown. Metagenomic sequencing has opened the door to accurately determine and analyze the entire microbial community of DW, providing a comprehensive understanding of DW species diversity, especially in the context of public health concerns during the COVID-19 era. In this study, we found that most of the culturable bacteria and some fecal indicator bacteria, such as Escherichia coli and Pseudomonas aeruginosa, were non-culturable using culture-dependent methods in all samples. However, metagenomic analysis showed that the predominant bacterial species in the DW samples belonged to the phyla Proteobacteria and Planctomycetes. Notably, the genus Methylobacterium was the most abundant in all water samples, followed by Sphingomonas, Gemmata, and Azospirilum. While low levels of virulence-associated factors, such as the Esx-5 type VII secretion system (T7SS) and DevR/S, were detected, only the erythromycin resistance gene erm(X), an rRNA methyltransferase, was identified at low abundance in one sample. Hosts corresponding to virulence and resistance genes were identified in some samples, including Mycobacterium spp. Archaeal DNA (Euryarchaeota, Crenarchaeota) was found in trace amounts in some DW samples. Viruses such as rotavirus, coxsackievirus, human enterovirus, and SARS-CoV-2 were negative in all DW samples using colloidal gold and real-time reverse transcription polymerase chain reaction (RT‒PCR) methods. However, DNA encoding a new order of reverse-transcribing viruses (Ortervirales) and Herpesvirales was found in some DW samples. The metabolic pathways of the entire microbial community involve cell‒cell communication and signal secretion, contributing to cooperation between different microbial populations in the water. This study provides insight into the microbial community and metabolic process of DW in Hangzhou, China, utilizing both culture-dependent methods and metagenomic sequencing combined with bioinformatics tools during the COVID-19 pandemic era.
Collapse
Affiliation(s)
- Wei Lan
- Department of Infectious Diseases, Sir Run Run Shaw Hospital, Zhejiang University School of Medicine, Hangzhou, 310016, China; Key Laboratory of Microbial Technology and Bioinformatics of Zhejiang Province, Hangzhou, 310016, China; Regional Medical Center for National Institute of Respiratory Diseases, Sir Run Run Shaw Hospital, Zhejiang University School of Medicine, Hangzhou, 310016, China
| | - Haiyang Liu
- Department of Infectious Diseases, Sir Run Run Shaw Hospital, Zhejiang University School of Medicine, Hangzhou, 310016, China; Key Laboratory of Microbial Technology and Bioinformatics of Zhejiang Province, Hangzhou, 310016, China; Regional Medical Center for National Institute of Respiratory Diseases, Sir Run Run Shaw Hospital, Zhejiang University School of Medicine, Hangzhou, 310016, China
| | - Rui Weng
- Department of Infectious Diseases, Sir Run Run Shaw Hospital, Zhejiang University School of Medicine, Hangzhou, 310016, China; Key Laboratory of Microbial Technology and Bioinformatics of Zhejiang Province, Hangzhou, 310016, China; Regional Medical Center for National Institute of Respiratory Diseases, Sir Run Run Shaw Hospital, Zhejiang University School of Medicine, Hangzhou, 310016, China
| | - Yaxiong Zeng
- College of Chemical and Biological Engineering, Zhejiang University, Hangzhou, 320013, China
| | - Jian Lou
- Yiwu Water Construction Group Co., Ltd., Yiwu, 322000, China
| | - Hongxin Xu
- Yiwu Water Construction Group Co., Ltd., Yiwu, 322000, China
| | - Yunsong Yu
- Department of Infectious Diseases, Sir Run Run Shaw Hospital, Zhejiang University School of Medicine, Hangzhou, 310016, China; Key Laboratory of Microbial Technology and Bioinformatics of Zhejiang Province, Hangzhou, 310016, China; Regional Medical Center for National Institute of Respiratory Diseases, Sir Run Run Shaw Hospital, Zhejiang University School of Medicine, Hangzhou, 310016, China
| | - Yan Jiang
- Department of Infectious Diseases, Sir Run Run Shaw Hospital, Zhejiang University School of Medicine, Hangzhou, 310016, China; Key Laboratory of Microbial Technology and Bioinformatics of Zhejiang Province, Hangzhou, 310016, China; Regional Medical Center for National Institute of Respiratory Diseases, Sir Run Run Shaw Hospital, Zhejiang University School of Medicine, Hangzhou, 310016, China.
| |
Collapse
|
11
|
Ke Y, Sun W, Chen Z, Zhu Y, Chen X, Yan S, Li Y, Xie S. Effects of disinfectant type and dosage on biofilm's activity, viability, microbiome and antibiotic resistome in bench-scale drinking water distribution systems. WATER RESEARCH 2024; 249:120958. [PMID: 38064782 DOI: 10.1016/j.watres.2023.120958] [Citation(s) in RCA: 12] [Impact Index Per Article: 12.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 10/07/2023] [Revised: 11/29/2023] [Accepted: 11/30/2023] [Indexed: 01/03/2024]
Abstract
Drinking water distribution systems (DWDSs) are important for supplying high-quality water to consumers and disinfectant is widely used to control microbial regrowth in DWDSs. However, the disinfectant's influences on microbial community and antibiotic resistome in DWDS biofilms and the underlying mechanisms driving their dynamics remain elusive. The study investigated the effects of chlorine and chloramine disinfection on the microbiome and antibiotic resistome of biofilms in bench-scale DWDSs using metagenomics assembly. Additionally, the biofilm activity and viability were monitored based on adenosine triphosphate (ATP) and flow cytometer (FCM) staining. The results showed that both chlorine and chloramine disinfectants decreased biofilm ATP, although chloramine at a lower dosage (1 mg/L) could increase it. Chloramine caused a greater decrease in living cells than chlorine. Furthermore, the disinfectants significantly lowered the microbial community diversity and altered microbial community structure. Certain bacterial taxa were enriched, such as Mycobacterium, Sphingomonas, Sphingopyxis, Azospira, and Dechloromonas. Pseudomonas aeruginosa exhibited high resistance towards disinfectants. The disinfectants also decreased the complexity of microbial community networks. Some functional taxa (e.g., Nitrospira, Nitrobacter, Nitrosomonas) were identified as keystones in chloramine-treated DWDS microbial ecological networks. Stochasticity drove biofilm microbial community assembly, and disinfectants increased the contributions of stochastic processes. Chlorine had greater promotion effects on antibiotic resistance genes (ARGs), mobile genetic elements (MGEs) and ARG hosts than chloramine. The disinfectants also selected pathogens, such as Acinetobacter baumannii and Klebsiella pneumonia, and these pathogens also harbored ARGs and MGEs. Overall, this study provides new insights into the effects of disinfectants on biofilm microbiome and antibiotic resistome, highlighting the importance of monitoring and managing disinfection practices in DWDSs.
Collapse
Affiliation(s)
- Yanchu Ke
- State Key Joint Laboratory of Environmental Simulation and Pollution Control, College of Environmental Sciences and Engineering, Peking University, Beijing 100871, China; School of Environment, Tsinghua University, Beijing 100084, China
| | - Wenjun Sun
- School of Environment, Tsinghua University, Beijing 100084, China; Research Institute for Environmental Innovation (Suzhou) Tsinghua, Suzhou 215163, China.
| | - Zhongyun Chen
- School of Environment, Tsinghua University, Beijing 100084, China
| | - Ying Zhu
- State Key Joint Laboratory of Environmental Simulation and Pollution Control, College of Environmental Sciences and Engineering, Peking University, Beijing 100871, China
| | - Xiuli Chen
- State Key Joint Laboratory of Environmental Simulation and Pollution Control, College of Environmental Sciences and Engineering, Peking University, Beijing 100871, China
| | - Shuang Yan
- State Key Joint Laboratory of Environmental Simulation and Pollution Control, College of Environmental Sciences and Engineering, Peking University, Beijing 100871, China
| | - Yangyang Li
- State Key Joint Laboratory of Environmental Simulation and Pollution Control, College of Environmental Sciences and Engineering, Peking University, Beijing 100871, China
| | - Shuguang Xie
- State Key Joint Laboratory of Environmental Simulation and Pollution Control, College of Environmental Sciences and Engineering, Peking University, Beijing 100871, China.
| |
Collapse
|
12
|
Zhao B, Liu R, Li Y, Xu H, Li X, Gu J, Zhang X, Wang Y, Wang Y. Changes of putative pathogenic species within the water bacterial community in large-scale drinking water treatment and distribution systems. WATER RESEARCH 2024; 249:120947. [PMID: 38043356 DOI: 10.1016/j.watres.2023.120947] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 07/06/2023] [Revised: 11/23/2023] [Accepted: 11/29/2023] [Indexed: 12/05/2023]
Abstract
Although the management of microbes in drinking water is of paramount importance for public health, there remain challenges in comprehensively examining pathogenic bacteria in the water supply system at the species level. In this study, high-throughput sequencing of nearly full-length 16S rRNA genes was performed to investigate the changes of the water bacterial community in three large-scale drinking water treatment plants (DWTPs) and their corresponding distribution systems during winter and summer. Our findings revealed significant differences in the bacterial community structure between winter and summer water samples for each DWTP and its distribution management area (DMA). In the groundwater-fed DWTP, selective enrichment of mycobacterial species was observed in both seasons, and the subsequent DMA also exhibited strong selection for specific mycobacterial species. In one of the surface water-fed DWTPs, certain Legionella species present in the source water in winter were selectively enriched in the bacterial community after pre-oxidation, although they were susceptible to the subsequent purification steps. A variety of putative pathogenic species (n = 83) were identified based on our pathogen identification pipeline, with the dominant species representing opportunistic pathogens commonly found in water supply systems. While pathogen removal primarily occurred during the purification processes of DWTPs, especially for surface water-fed plants, the relative abundance of pathogenic bacteria in the DMA water flora was lower than that in the DWTP effluent flora, indicating a diminished competitiveness of pathogens within the DMA ecosystem.
Collapse
Affiliation(s)
- Bei Zhao
- Beijing Waterworks Group Co., Ltd, Beijing, PR China; Beijing Engineering Research Center for Drinking Water Quality, Beijing, PR China
| | - Ruyin Liu
- College of Resources and Environment, University of Chinese Academy of Sciences, Beijing, PR China; Weiqiao-UCAS Science and Technology Park, Binzhou Institute of Technology, Binzhou, Shandong, PR China.
| | - Yuxian Li
- Beijing Waterworks Group Co., Ltd, Beijing, PR China; Beijing Engineering Research Center for Drinking Water Quality, Beijing, PR China
| | - Hao Xu
- Beijing Waterworks Group Co., Ltd, Beijing, PR China; Beijing Engineering Research Center for Drinking Water Quality, Beijing, PR China
| | - Xiangyi Li
- Beijing Waterworks Group Co., Ltd, Beijing, PR China; Beijing Engineering Research Center for Drinking Water Quality, Beijing, PR China
| | - Junnong Gu
- Beijing Waterworks Group Co., Ltd, Beijing, PR China; Beijing Engineering Research Center for Drinking Water Quality, Beijing, PR China
| | - Xiaolan Zhang
- Beijing Waterworks Group Co., Ltd, Beijing, PR China; Beijing Engineering Research Center for Drinking Water Quality, Beijing, PR China
| | - Yue Wang
- Beijing Waterworks Group Co., Ltd, Beijing, PR China
| | - Yansong Wang
- College of Resources and Environment, University of Chinese Academy of Sciences, Beijing, PR China
| |
Collapse
|
13
|
Guo L, Ze X, Feng H, Liu Y, Ge Y, Zhao X, Song C, Jiao Y, Liu J, Mu S, Yao S. Identification and quantification of viable Lacticaseibacillus rhamnosus in probiotics using validated PMA-qPCR method. Front Microbiol 2024; 15:1341884. [PMID: 38298895 PMCID: PMC10828034 DOI: 10.3389/fmicb.2024.1341884] [Citation(s) in RCA: 5] [Impact Index Per Article: 5.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/21/2023] [Accepted: 01/03/2024] [Indexed: 02/02/2024] Open
Abstract
The identification and quantification of viable bacteria at the species/strain level in compound probiotic products is challenging now. Molecular biology methods, e.g., propidium monoazide (PMA) combination with qPCR, have gained prominence for targeted viable cell counts. This study endeavors to establish a robust PMA-qPCR method for viable Lacticaseibacillus rhamnosus detection and systematically validated key metrics encompassing relative trueness, accuracy, limit of quantification, linear, and range. The inclusivity and exclusivity notably underscored high specificity of the primers for L. rhamnosus, which allowed accurate identification of the target bacteria. Furthermore, the conditions employed for PMA treatment were fully verified by 24 different L. rhamnosus including type strain, commercial strains, etc., confirming its effective discrimination between live and dead bacteria. A standard curve constructed by type strain could apply to commercial strains to convert qPCR Cq values to viable cell numbers. The established PMA-qPCR method was applied to 46 samples including pure cultures, probiotics as food ingredients, and compound probiotic products. Noteworthy is the congruity observed between measured and theoretical values within a 95% confidence interval of the upper and lower limits of agreement, demonstrating the relative trueness of this method. Moreover, accurate results were obtained when viable L. rhamnosus ranging from 103 to 108 CFU/mL. The comprehensive appraisal of PMA-qPCR performances provides potential industrial applications of this new technology in quality control and supervision of probiotic products.
Collapse
Affiliation(s)
- Lizheng Guo
- China National Research Institute of Food and Fermentation Industries Co., LTD., China Center of Industrial Culture Collection, Beijing, China
| | - Xiaolei Ze
- Microbiome Research and Application Center, BYHEALTH Institute of Nutrition & Health, Guangzhou, China
| | - Huifen Feng
- China National Research Institute of Food and Fermentation Industries Co., LTD., China Center of Industrial Culture Collection, Beijing, China
| | - Yiru Liu
- China National Research Institute of Food and Fermentation Industries Co., LTD., China Center of Industrial Culture Collection, Beijing, China
| | - Yuanyuan Ge
- China National Research Institute of Food and Fermentation Industries Co., LTD., China Center of Industrial Culture Collection, Beijing, China
| | - Xi Zhao
- Microbiome Research and Application Center, BYHEALTH Institute of Nutrition & Health, Guangzhou, China
| | - Chengyu Song
- China National Research Institute of Food and Fermentation Industries Co., LTD., China Center of Industrial Culture Collection, Beijing, China
| | - Yingxin Jiao
- China National Research Institute of Food and Fermentation Industries Co., LTD., China Center of Industrial Culture Collection, Beijing, China
| | - Jiaqi Liu
- China National Research Institute of Food and Fermentation Industries Co., LTD., China Center of Industrial Culture Collection, Beijing, China
| | - Shuaicheng Mu
- China National Research Institute of Food and Fermentation Industries Co., LTD., China Center of Industrial Culture Collection, Beijing, China
| | - Su Yao
- China National Research Institute of Food and Fermentation Industries Co., LTD., China Center of Industrial Culture Collection, Beijing, China
| |
Collapse
|
14
|
Abkar L, Moghaddam HS, Fowler SJ. Microbial ecology of drinking water from source to tap. THE SCIENCE OF THE TOTAL ENVIRONMENT 2024; 908:168077. [PMID: 37914126 DOI: 10.1016/j.scitotenv.2023.168077] [Citation(s) in RCA: 7] [Impact Index Per Article: 7.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 07/27/2023] [Revised: 10/20/2023] [Accepted: 10/21/2023] [Indexed: 11/03/2023]
Abstract
As drinking water travels from its source, through various treatment processes, hundreds to thousands of kilometres of distribution network pipes, to the taps in private homes and public buildings, it is exposed to numerous environmental changes, as well as other microbes living in both water and on surfaces. This review aims to identify the key locations and factors that are associated with changes in the drinking water microbiome throughout conventional urban drinking water systems from the source to the tap water. Over the past 15 years, improvements in cultivation-independent methods have enabled studies that allow us to answer such questions. As a result, we are beginning to move towards predicting the impacts of disturbances and interventions resulting ultimately in management of drinking water systems and microbial communities rather than mere observation. Many challenges still exist to achieve effective management, particularly within the premise plumbing environment, which exhibits diverse and inconsistent conditions that may lead to alterations in the microbiota, potentially presenting public health risks. Finally, we recommend the establishment of global collaborative projects on the drinking water microbiome that will enhance our current knowledge and lead to tools for operators and researchers alike to improve global access to high-quality drinking water.
Collapse
Affiliation(s)
- Leili Abkar
- Civil Engineering Department, University of British Columbia, Canada.
| | | | - S Jane Fowler
- Department of Biological Sciences, Simon Fraser University, Canada.
| |
Collapse
|
15
|
Foster AR, Haas CN, Gerba CP, Pepper IL. Effectiveness of monochloramine for inactivation of coronavirus in reclaimed water. THE SCIENCE OF THE TOTAL ENVIRONMENT 2024; 906:167634. [PMID: 37806580 DOI: 10.1016/j.scitotenv.2023.167634] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 06/02/2023] [Revised: 10/04/2023] [Accepted: 10/05/2023] [Indexed: 10/10/2023]
Abstract
Fecal shedding of severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) by infected persons into wastewater was documented early during the COVID-19 pandemic, thereby stimulating inquiries into the effectiveness of municipal wastewater treatment processes for the reduction of infectious viruses. In wastewater treatment plants, free chlorine has traditionally been the disinfectant utilized due to its low cost and high efficacy. However, regulations limiting disinfection by-products have prompted a shift to chloramination in many areas of the United States. While studies regarding the effectiveness of free chlorine against many viral agents are abundant, the efficacy of monochloramine (NH2Cl) has been less well researched. This study aimed to determine the effectiveness of pre-formed monochloramine for disinfection of human coronavirus 229E (HCoV-229E) in both phosphate-buffered saline (PBS) and reclaimed water from a water reclamation plant in Tucson, Arizona. Reclaimed water was sampled over the course of six months (August 2020 to November 2020), and dosed with monochloramine at 3 mg/L. An additional 1 mg/L free ammonia was added to simulate the operational conditions of the treatment plant. Viability was determined using MRC-5 host cell monolayers, using the TCID50 assay method. An average Ct99.9 (concentration of disinfectant multiplied by the contact time to achieve a 99.9 % reduction of the target organism) of 176 mg*min/L monochloramine was determined. No significant difference in inactivation rate was observed between the dosed reclaimed water and phosphate buffered saline (PBS). These data indicate that monochloramine is an effective disinfectant for coronaviruses. They also indicate that the water matrix type did not significantly impact the disinfection efficacy of monochloramine against HCoV-229E in reclaimed wastewater compared to PBS.
Collapse
Affiliation(s)
- Aidan R Foster
- Water & Energy Sustainable Technology (WEST) Center, University of Arizona, Tucson, AZ, USA.
| | - Charles N Haas
- Department of Civil, Architectural and Environmental Engineering, Drexel University, Philadelphia, PA, USA.
| | - Charles P Gerba
- Water & Energy Sustainable Technology (WEST) Center, University of Arizona, Tucson, AZ, USA.
| | - Ian L Pepper
- Water & Energy Sustainable Technology (WEST) Center, University of Arizona, Tucson, AZ, USA.
| |
Collapse
|
16
|
Liu S, Li Q, Jiang R, Liu P, Zhang XX. Shift of human pathogen community composition and their potential human health risk after supply suspension in tap water. Sci Rep 2023; 13:12419. [PMID: 37528119 PMCID: PMC10393962 DOI: 10.1038/s41598-023-39225-z] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/30/2023] [Accepted: 07/21/2023] [Indexed: 08/03/2023] Open
Abstract
Water supply suspension-restoration can occur frequently due to the overhauling of civil infrastructure in developing countries and the shutdown of commercial buildings during the pandemic. For comprehensive insights into the effects of water supply suspension-restoration, this study characterized the variations of the pathogen community composition of the tap water and their infection risk under different water supply scenarios. Metagenomic sequencing revealed a significant change of the human pathogen profiles, among which the most dominant pathogen changed from Pseudomonas aeruginosa (4.91%) to Acinetobacter johnsonii (0.59%). Furthermore, absolute quantification of pathogens by propidium-monoazide-qPCR revealed that the abundance of the three typical pathogens (Pseudomonas aeruginosa, Mycobacterium avium and Salmonella sp.) showed an increase of 2.44 log to 3.60 log immediately after water supply suspension-restoration and did not return to the normal level even after 2-h supply restoration, except for Pseudomonas aeruginosa. Quantitative microbial risk assessment suggested the infection risks of the three pathogens arising from direct utilization of tap water under stable water supply, including dermal exposure and oral intake, were all above the threshold of 10-4, and evidently increased after water supply suspension-restoration. This study warns us against the risk induced by the pathogens in tap water, especially after water supply suspension-restoration.
Collapse
Affiliation(s)
- Shengnan Liu
- State Key Laboratory of Pollution Control and Resource Reuse, School of the Environment, Nanjing University, 163 Xianlin Road, Nanjing, 210023, China
| | - Qisheng Li
- China Three Gorges Construction Engineering Corporation, Beijing, 100048, China
| | - Ruiming Jiang
- State Key Laboratory of Pollution Control and Resource Reuse, School of the Environment, Nanjing University, 163 Xianlin Road, Nanjing, 210023, China
| | - Peng Liu
- State Key Laboratory of Pollution Control and Resource Reuse, School of the Environment, Nanjing University, 163 Xianlin Road, Nanjing, 210023, China.
| | - Xu-Xiang Zhang
- State Key Laboratory of Pollution Control and Resource Reuse, School of the Environment, Nanjing University, 163 Xianlin Road, Nanjing, 210023, China.
| |
Collapse
|
17
|
Pan R, Zhang TY, Zheng ZX, Ai J, Ye T, Zhao HX, Hu CY, Tang YL, Fan JJ, Geng B, Xu B. Insight into mixed chlorine/chloramines conversion and associated water quality variability in drinking water distribution systems. THE SCIENCE OF THE TOTAL ENVIRONMENT 2023; 880:163297. [PMID: 37028653 DOI: 10.1016/j.scitotenv.2023.163297] [Citation(s) in RCA: 2] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 02/06/2023] [Revised: 03/29/2023] [Accepted: 04/01/2023] [Indexed: 05/27/2023]
Abstract
Mixed chlorine/chloramines are common in drinking water distribution systems (DWDSs); however, their transformation and impact on chemical and microbial characteristics are not well understood. We systematically investigated water quality parameters associated with mixed chlorine/chloramine species conversion in 192 samples (including raw, finished, and tap water) collected throughout the year in a city in East China. Various chlorine/chloramine species (free chlorine, monochloramine [NH2Cl], dichloramine [NHCl2], and organic chloramines [OC]) were detected in both chlorinated and chloraminated DWDSs. NHCl2 + OC increased with transport distance along the pipeline network. The maximum proportion of NHCl2 + OC in over total chlorine in tap water reached 66 % and 38 % from chlorinated and chloraminated DWDSs, respectively. Both free chlorine and NH2Cl showed a rapid decay in the water pipe systems, but NHCl2 and OC were more persistent. Correlations between chlorine/chloramine species and physicochemical parameters were established. Models for predicting the sum of chloroform/TCM, bromodichloromethane/BDCM, chlorodibromomethane/CBDM, and bromoform/TBM (THM4) (R2 = 0.56) and haloacetic acids (HAAs) (R2 = 0.65) exhibited greater accuracy based on machine learning tuned with chlorine/chloramine species, particularly NHCl2 + OC. The predominant bacterial communities in mixed chlorine/chloramine systems were those resistant to chlorine or chloramine such as proteobacteria. NH2Cl was the most significant explanatory factor (28.1 %) for the variation in microbial community assemblage in chloraminated DWDSs. Although residual free chlorine and NHCl2 + OC, accounted for a smaller proportion of chlorine species in chloraminated DWDSs, they played an essential role (12.4 % and 9.1 %, respectively) in the microbial community structure.
Collapse
Affiliation(s)
- Renjie Pan
- State Key Laboratory of Pollution Control and Resource Reuse, Key Laboratory of Urban Water Supply, Water Saving and Water Environment Governance in the Yangtze River Delta of Ministry of Water Resources, College of Environmental Science and Engineering, Tongji University, Shanghai 200092, PR China; Shanghai Institute of Pollution Control and Ecological Security, Shanghai 200092, PR China
| | - Tian-Yang Zhang
- State Key Laboratory of Pollution Control and Resource Reuse, Key Laboratory of Urban Water Supply, Water Saving and Water Environment Governance in the Yangtze River Delta of Ministry of Water Resources, College of Environmental Science and Engineering, Tongji University, Shanghai 200092, PR China; Shanghai Institute of Pollution Control and Ecological Security, Shanghai 200092, PR China
| | - Zheng-Xiong Zheng
- State Key Laboratory of Pollution Control and Resource Reuse, Key Laboratory of Urban Water Supply, Water Saving and Water Environment Governance in the Yangtze River Delta of Ministry of Water Resources, College of Environmental Science and Engineering, Tongji University, Shanghai 200092, PR China; Shanghai Institute of Pollution Control and Ecological Security, Shanghai 200092, PR China
| | - Jian Ai
- State Key Laboratory of Pollution Control and Resource Reuse, Key Laboratory of Urban Water Supply, Water Saving and Water Environment Governance in the Yangtze River Delta of Ministry of Water Resources, College of Environmental Science and Engineering, Tongji University, Shanghai 200092, PR China; Shanghai Institute of Pollution Control and Ecological Security, Shanghai 200092, PR China
| | - Tao Ye
- Department of Civil and Environmental Engineering, South Dakota School of Mines and Technology, Rapid City, SD 57701, USA
| | - Heng-Xuan Zhao
- State Key Laboratory of Pollution Control and Resource Reuse, Key Laboratory of Urban Water Supply, Water Saving and Water Environment Governance in the Yangtze River Delta of Ministry of Water Resources, College of Environmental Science and Engineering, Tongji University, Shanghai 200092, PR China; Shanghai Institute of Pollution Control and Ecological Security, Shanghai 200092, PR China
| | - Chen-Yan Hu
- College of Environmental and Chemical Engineering, Shanghai University of Electric Power, Shanghai 200090, PR China
| | - Yu-Lin Tang
- State Key Laboratory of Pollution Control and Resource Reuse, Key Laboratory of Urban Water Supply, Water Saving and Water Environment Governance in the Yangtze River Delta of Ministry of Water Resources, College of Environmental Science and Engineering, Tongji University, Shanghai 200092, PR China; Shanghai Institute of Pollution Control and Ecological Security, Shanghai 200092, PR China
| | - Jing-Jing Fan
- Shanghai Chengtou Water (Group) Co. LTD, Shanghai 200002, PR China
| | - Bing Geng
- Shanghai Chengtou Water (Group) Co. LTD, Shanghai 200002, PR China
| | - Bin Xu
- State Key Laboratory of Pollution Control and Resource Reuse, Key Laboratory of Urban Water Supply, Water Saving and Water Environment Governance in the Yangtze River Delta of Ministry of Water Resources, College of Environmental Science and Engineering, Tongji University, Shanghai 200092, PR China; Shanghai Institute of Pollution Control and Ecological Security, Shanghai 200092, PR China.
| |
Collapse
|
18
|
Li T, Zhang Y, Gan J, Yu X, Wang L. Superiority of UV222 radiation by in situ aquatic electrode KrCl excimer in disinfecting waterborne pathogens: Mechanism and efficacy. JOURNAL OF HAZARDOUS MATERIALS 2023; 452:131292. [PMID: 36989776 DOI: 10.1016/j.jhazmat.2023.131292] [Citation(s) in RCA: 6] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 02/13/2023] [Revised: 03/13/2023] [Accepted: 03/23/2023] [Indexed: 05/03/2023]
Abstract
Microbial safety in water has always been the focus of attention, especially during the COVID-19 pandemic. Development of green, efficient and safe disinfection technology is the key to control the spread of pathogenic microorganisms. Here, an in situ aquatic electrode KrCl excimer radiation with main emission wavelength 222 nm (UV222) was designed and used to disinfect model waterborne virus and bacteria, i.e. phage MS2, E. coli and S. aureus. High inactivation efficacy and diversity of inactivation mechanisms of UV222 were proved by comparision with those of commercial UV254. UV222 could totally inactivate MS2, E. coli and S. aureus with initial concentrations of ∼107 PFU or CFU mL-1 within 20, 15, and 36 mJ/cm2, respectively. The UV dose required by UV254 to inactivate the same logarithmic pathogenic microorganism is at least twice that of UV222. The protein, genomic and cell membrane irreparable damage contributed to the microbial inactivation by UV222, but UV254 only act on nucleic acid of the target microorganisms. We found that UV222 damage nucleic acid with almost the same or even higher efficacy with UV254. In addition, free base damage of UV222 in similar ways with UV254(dimer and hydrate). But due to the quantum yield of free base degradation of UV222 was greater than UV254, the photolysis rates of UV222 to A, G, C and U four bases were 11.5, 1.2, 3.2 and 1 times as those of UV254, respectively. Excellent disinfection performance in UV222 irradiation was also achieved in real water matrices (WWTP and Lake). In addition, it was proved that coexisting HCO3- or HPO42 - in real and synthetic water matrices can produce • OH to promote UV222 disinfection. This study provided novel insight into the UV222 disinfection process and demonstrated its possibility to take place of the conventional ultraviolet mercury lamp in water purification.
Collapse
Affiliation(s)
- Ting Li
- Water Resources and Environmental Institute, Xiamen University of Technology, Xiamen 361024, China
| | - Yizhan Zhang
- Water Resources and Environmental Institute, Xiamen University of Technology, Xiamen 361024, China
| | - Jiaming Gan
- Water Resources and Environmental Institute, Xiamen University of Technology, Xiamen 361024, China
| | - Xin Yu
- College of the Environment & Ecology, Xiamen University, Xiamen 361102, China.
| | - Lei Wang
- Water Resources and Environmental Institute, Xiamen University of Technology, Xiamen 361024, China.
| |
Collapse
|
19
|
Tang Y, Zhang H, Yan J, Luo N, Fu X, Wu X, Wu J, Liu C, Zhang D. Assessing the efficacy of bleaching powder in disinfecting marine water: Insights from the rapid recovery of microbiomes. WATER RESEARCH 2023; 241:120136. [PMID: 37295228 DOI: 10.1016/j.watres.2023.120136] [Citation(s) in RCA: 6] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 03/15/2023] [Revised: 05/20/2023] [Accepted: 05/26/2023] [Indexed: 06/12/2023]
Abstract
Single-bleaching powder disinfection is a highly prevalent practice to disinfect source water for marine aquaculture to prevent diseases. However, due to the decay of active chlorine and the presence of disinfectant resistance bacteria (DRB), the effects of bleaching powder on prokaryotic community compositions (PCCs) and function in marine water remain unknown. In the present study, the source water in a canvas pond was treated with the normal dose of bleaching powder, and the impact on PCCs and functional profiles was investigated using 16S rRNA gene amplicon sequencing. The bleaching powder strongly altered the PCCs within 0.5 h, but they began to recover at 16 h, eventually achieving 76% similarity with the initial time at 72 h. This extremely rapid recovery was primarily driven by the decay of Bacillus and the regrowth of Pseudoalteromonas, both of which are DRB. Abundant community not only help PCCs recover but also provide larger functional redundancy than rare community. During the recovery of PCCs, stochastic processes drove the community assembly. After 72 h, five out of seven identified disinfectant resistance genes related to efflux pump systems were highly enriched, primarily in Staphylococcus and Bacillus. However, 15 out of the 16 identified antibiotic resistance genes (ARGs) remained unchanged compared to the initial time, indicating that bleaching powder does not contribute to ARGs removal. Overall, the findings demonstrate that single-bleaching powder disinfection cannot successfully meet the objective of disease prevention in marine aquaculture water due to the extremely rapid recovery of PCCs. Hence, secondary disinfection or novel disinfection strategies should be explored for source water disinfection.
Collapse
Affiliation(s)
- Yawen Tang
- State Key Laboratory for Managing Biotic and Chemical Threats to the Quality and Safety of Agro-products, Ningbo University, Ningbo 315211, China; Key Laboratory of Marine Biotechnology of Zhejiang Province, School of Marine Sciences, Ningbo University, Ningbo 315211, China
| | - Huajun Zhang
- State Key Laboratory for Managing Biotic and Chemical Threats to the Quality and Safety of Agro-products, Ningbo University, Ningbo 315211, China; Marine Economic Research Center, Donghai Academy, Ningbo University, Ningbo 315211, China; Key Laboratory of Marine Biotechnology of Zhejiang Province, School of Marine Sciences, Ningbo University, Ningbo 315211, China.
| | - Jiaojiao Yan
- State Key Laboratory for Managing Biotic and Chemical Threats to the Quality and Safety of Agro-products, Ningbo University, Ningbo 315211, China; Key Laboratory of Marine Biotechnology of Zhejiang Province, School of Marine Sciences, Ningbo University, Ningbo 315211, China
| | - Nan Luo
- State Key Laboratory for Managing Biotic and Chemical Threats to the Quality and Safety of Agro-products, Ningbo University, Ningbo 315211, China; Key Laboratory of Marine Biotechnology of Zhejiang Province, School of Marine Sciences, Ningbo University, Ningbo 315211, China
| | - Xuezhi Fu
- State Key Laboratory for Managing Biotic and Chemical Threats to the Quality and Safety of Agro-products, Ningbo University, Ningbo 315211, China; Key Laboratory of Marine Biotechnology of Zhejiang Province, School of Marine Sciences, Ningbo University, Ningbo 315211, China
| | - Xiaoyu Wu
- State Key Laboratory for Managing Biotic and Chemical Threats to the Quality and Safety of Agro-products, Ningbo University, Ningbo 315211, China; Key Laboratory of Marine Biotechnology of Zhejiang Province, School of Marine Sciences, Ningbo University, Ningbo 315211, China
| | - Jialin Wu
- Ningbo Haiwei Ecological Technology Co., Ltd., Ningbo 315141, China
| | - Changjun Liu
- Xiangshan Fisheries Technical Extension Center, Ningbo 315700, China
| | - Demin Zhang
- State Key Laboratory for Managing Biotic and Chemical Threats to the Quality and Safety of Agro-products, Ningbo University, Ningbo 315211, China; Key Laboratory of Marine Biotechnology of Zhejiang Province, School of Marine Sciences, Ningbo University, Ningbo 315211, China.
| |
Collapse
|
20
|
Jiang Q, Li H, Wan K, Ye C, Yu X. Quantification and antibiotic resistance risk assessment of chlorination-residual viable/VBNC Escherichia coli and Enterococcus in on-site hospital wastewater treatment system. THE SCIENCE OF THE TOTAL ENVIRONMENT 2023; 872:162139. [PMID: 36773911 DOI: 10.1016/j.scitotenv.2023.162139] [Citation(s) in RCA: 7] [Impact Index Per Article: 3.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 11/27/2022] [Revised: 01/24/2023] [Accepted: 02/05/2023] [Indexed: 06/18/2023]
Abstract
On-site hospital wastewater treatment system widely applying chlorination has been regarded as an important barrier to curb the dissemination of antibiotic resistance. Chlorination-residual viable and viable but non-culturable (VBNC) bacteria probably lead to overestimate the effect of disinfection, while their antibiotic resistance risks imported from hospital effluents to municipal pipe network may be ignored. In this study, we quantified viable/VBNC Escherichia coli and Enterococcus in chlorination of an on-site hospital wastewater treatment system and assessed their antibiotic resistance risks. The numbers of viable/VBNC Escherichia coli and Enterococcus in raw wastewater were detected as high as 5.76-6.34/5.76-6.33 and 5.44-5.76/5.44-5.75 log10(cells/mL). Meanwhile, high proportions of antibiotic-resistant Escherichia coli and Enterococcus to culturable Escherichia coli and Enterococcus were observed, especially carrying ampicillin resistance (22.25-41.70 % and 28.09-54.05 %). Chlorination could remove 0.44-1.88-/0.43-1.88- and 0.29-1.29-/0.28-1.28-log of viable/VBNC and complete culturable Escherichia coli and Enterococcus, but cause antibiotic resistance genes (ARGs) and mobile genetic elements (MGEs) to be released outside cells, and possibly further enhance the antibiotic resistance of viable bacteria. Low detections of antibiotics suggested that the occurrence of antibiotic-resistant bacteria (ARB) may not be accompanied by the corresponding antibiotics. Different sampling months had some impacts on above results, while the results were basically stable at different sampling times of hospital daily working period. The high release rates (11.26-13.02 and 11.59-12.98 log10(cells/h)) and cumulative amounts (15.41-16.12 and 15.75-16.14 log10(cells)) of chlorination-residual viable/VBNC Escherichia coli and Enterococcus indirectly assessed the potential risks of bacterial antibiotic resistance entering municipal pipe network. Additionally, the contributions from the corresponding antibiotic ceftazidime, ciprofloxacin, and vancomycin with the cumulative amounts of 2.57-4.85, 5.73-7.50, and 5.21-7.14 kg should also be taken seriously. Residual chlorine could serve as an important signal indicator for the risk assessment.
Collapse
Affiliation(s)
- Qi Jiang
- College of the Environment and Ecology, Xiamen University, Xiamen 361102, China
| | - Haoran Li
- College of the Environment and Ecology, Xiamen University, Xiamen 361102, China
| | - Kun Wan
- College of the Environment and Ecology, Xiamen University, Xiamen 361102, China
| | - Chengsong Ye
- College of the Environment and Ecology, Xiamen University, Xiamen 361102, China
| | - Xin Yu
- College of the Environment and Ecology, Xiamen University, Xiamen 361102, China.
| |
Collapse
|
21
|
Štiglić J, Ujević Bošnjak M, Héry M, Kurajica L, Kinsela AS, Casiot C, Capak K. Bacterial diversity across four drinking water distribution systems in Croatia: impacts of water management practices and disinfection by-products. FEMS Microbiol Ecol 2022; 99:fiac146. [PMID: 36473705 DOI: 10.1093/femsec/fiac146] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/17/2024] Open
Abstract
Several factors may impact bacterial diversity in drinking water distribution systems (DWDSs) including the origin of the raw water, the water treatment technologies, and the disinfection practices applied. 16S rRNA metabarcoding was used for the in-depth characterization of bacterial communities in the four studied Croatian DWDSs (A, B, C, D) two of which had residual disinfectant (A, B) and two were without (C, D), while only B utilized the conventional water treatment technology. Significantly higher diversity and species richness were evidenced in non-disinfected DWDSs (p<0.05) compared to disinfected DWDSs. The phylum Proteobacteria was the most abundant in all the DWDSs, being proportionately higher in non-disinfected systems (p<0.05). The most abundant genera in DWDS-A Mycobacterium and Sphingomonas both positively correlated, whereas Lactobacillus negatively correlated with the concentration of disinfection by-products (DBPs) as a sum of haloacetic acids (HAAs). Conversely, the genus Ralstonia positively correlated with the individual DBP dichloroacetic acid. These results indicate that genera Sphingomonas, Mycobacterium, Lactobacillus and Ralstonia could have an effect on promoting the formation of DBPs, in a similar manner to how negatively correlated taxa may influence their degradation.
Collapse
Affiliation(s)
- J Štiglić
- Croatian Institute of Public Health, Rockefellerova 7, 10000 Zagreb, Croatia
| | - M Ujević Bošnjak
- Croatian Institute of Public Health, Rockefellerova 7, 10000 Zagreb, Croatia
| | - M Héry
- HydroSciences Montpellier, University of Montpellier, CNRS, IRD, Montpellier, France
| | - L Kurajica
- Croatian Institute of Public Health, Rockefellerova 7, 10000 Zagreb, Croatia
| | - A S Kinsela
- Water Research Centre, School of Civil and Environmental Engineering, University of New South Wales, Sydney, NSW 2052, Australia
| | - C Casiot
- HydroSciences Montpellier, University of Montpellier, CNRS, IRD, Montpellier, France
| | - K Capak
- Croatian Institute of Public Health, Rockefellerova 7, 10000 Zagreb, Croatia
| |
Collapse
|
22
|
Liu L, Zheng Y, Ruan H, Li L, Zhao L, Zhang M, Duan L, He S. Drinking natural water unchangeably is associated with reduced all-cause mortality in elderly people: A longitudinal prospective study from China. Front Public Health 2022; 10:981782. [PMID: 36072371 PMCID: PMC9441631 DOI: 10.3389/fpubh.2022.981782] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/29/2022] [Accepted: 08/05/2022] [Indexed: 01/25/2023] Open
Abstract
Objective Because of rapid economic growth and followed urban expansion in China, many people drinking natural water had to change their water sources to tap water. We aimed to test the unknown association that whether continued use of natural water for drinking is different from switching to tap water in all-cause mortality risks in elderly people. Methods In total, based on Chinese Longitudinal Healthy Longevity Survey, 26,688 elderly participants drinking natural water from childhood to young-old were included in the final analyses. Associations between whether changing drinking water sources or not and all-cause mortality risk were then estimated by Cox regression models with the use of multiple propensity score methods, and the primary analysis used propensity score matching, with other propensity score methods confirming the robustness of the results. Results Baseline characteristics were fairly well balanced by the three post-randomization methods. During a median follow-up period of 3.00 (IQR: 1.52, 5.73) years, 21,379 deaths were recorded. The primary analysis showed people using natural water unchangeably was associated with a lower risk of all-cause mortality than those switching to tap water in later life (HR: 0.94, 95% CI: 0.91-0.97, p < 0.001). Other propensity score methods, as well as Cox regression analysis without using propensity score methods, showed similar results. Conclusions Among elderly people depending on natural water for drinking from their childhood to young-old in China, continued use of natural water was associated with a lower all-cause mortality risk than conversion to tap water later. Further studies in different countries and populations are needed to verify our conclusions.
Collapse
Affiliation(s)
- Lu Liu
- Department of Cardiology, West China Hospital of Sichuan University, Chengdu, China
| | - Yi Zheng
- Department of Cardiology, West China Hospital of Sichuan University, Chengdu, China
| | - Haiyan Ruan
- Department of Cardiology, West China Hospital of Sichuan University, Chengdu, China,Department of Cardiology, Hospital of Traditional Chinese Medicine of Shuangliu District, Chengdu, China
| | - Liying Li
- Department of Cardiology, West China Hospital of Sichuan University, Chengdu, China
| | - Liming Zhao
- Department of Cardiovascular Medicine, Hospital of Chengdu Office of People's Government of Tibetan Autonomous Region, Chengdu, China
| | - Muxin Zhang
- Department of Cardiology, West China Hospital of Sichuan University, Chengdu, China,Department of Cardiology, First People's Hospital of Longquanyi District, Chengdu, China
| | - Linjia Duan
- Department of Cardiology, West China Hospital of Sichuan University, Chengdu, China
| | - Sen He
- Department of Cardiology, West China Hospital of Sichuan University, Chengdu, China,*Correspondence: Sen He
| |
Collapse
|
23
|
Nadimpalli ML, Lanza VF, Montealegre MC, Sultana S, Fuhrmeister ER, Worby CJ, Teichmann L, Caduff L, Swarthout JM, Crider YS, Earl AM, Brown J, Luby SP, Islam MA, Julian TR, Pickering AJ. Drinking water chlorination has minor effects on the intestinal flora and resistomes of Bangladeshi children. Nat Microbiol 2022; 7:620-629. [PMID: 35422497 PMCID: PMC9249080 DOI: 10.1038/s41564-022-01101-3] [Citation(s) in RCA: 18] [Impact Index Per Article: 6.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/30/2021] [Accepted: 02/24/2022] [Indexed: 02/07/2023]
Abstract
Healthy development of the gut microbiome provides long-term health benefits. Children raised in countries with high infectious disease burdens are frequently exposed to diarrhoeal pathogens and antibiotics, which perturb gut microbiome assembly. A recent cluster-randomized trial leveraging >4,000 child observations in Dhaka, Bangladesh, found that automated water chlorination of shared taps effectively reduced child diarrhoea and antibiotic use. In this substudy, we leveraged stool samples collected from 130 children 1 year after chlorine doser installation to examine differences between treatment and control children's gut microbiota. Water chlorination was associated with increased abundance of several bacterial genera previously linked to improved gut health; however, we observed no effects on the overall richness or diversity of taxa. Several clinically relevant antibiotic resistance genes were relatively more abundant in the gut microbiome of treatment children, possibly due to increases in Enterobacteriaceae. While further studies on the long-term health impacts of drinking chlorinated water would be valuable, we conclude that access to chlorinated water did not substantially impact child gut microbiome development in this setting, supporting the use of chlorination to increase global access to safe drinking water.
Collapse
Affiliation(s)
- Maya L. Nadimpalli
- Department of Civil and Environmental Engineering, Tufts University, Medford, MA, USA,Stuart B. Levy Center for Integrated Management of Antimicrobial Resistance (Levy CIMAR), Tufts University, Boston, MA, USA
| | - Val F. Lanza
- Bioinformatics Unit, Ramón y Cajal Health Research Institute (IRYCIS), Madrid, Spain,Network Research Center for Infectious Diseases (CIBERINFEC), Spain
| | | | - Sonia Sultana
- International Centre for Diarrhoeal Disease Research, Bangladesh (icddr,b), Dhaka, Bangladesh
| | - Erica R. Fuhrmeister
- Department of Civil and Environmental Engineering, Tufts University, Medford, MA, USA
| | - Colin J. Worby
- Infectious Disease & Microbiome Program, Broad Institute, Cambridge, MA
| | - Lisa Teichmann
- Eawag, Swiss Federal Institute of Aquatic Science and Technology, Dübendorf, Switzerland
| | - Lea Caduff
- Eawag, Swiss Federal Institute of Aquatic Science and Technology, Dübendorf, Switzerland
| | - Jenna M. Swarthout
- Department of Civil and Environmental Engineering, Tufts University, Medford, MA, USA
| | - Yoshika S. Crider
- Energy and Resources Group, University of California Berkeley, Berkeley, CA, USA,King Center on Global Development, Stanford University, Stanford, CA, USA
| | - Ashlee M. Earl
- Infectious Disease & Microbiome Program, Broad Institute, Cambridge, MA
| | - Joe Brown
- Department of Environmental Sciences and Engineering, Gillings School of Global Public Health, University of North Carolina, Chapel Hill, NC, USA
| | - Stephen P. Luby
- Infectious Diseases and Geographic Medicine, Stanford University, Stanford, CA, USA
| | - Mohammad Aminul Islam
- Eawag, Swiss Federal Institute of Aquatic Science and Technology, Dübendorf, Switzerland,Paul G. Allen School for Global Health, Washington State University, Pullman, WA, USA
| | - Timothy R. Julian
- Network Research Center for Infectious Diseases (CIBERINFEC), Spain,Swiss Tropical and Public Health Institute, Basel, Switzerland,University of Basel, Basel, Switzerland
| | - Amy J. Pickering
- Stuart B. Levy Center for Integrated Management of Antimicrobial Resistance (Levy CIMAR), Tufts University, Boston, MA, USA,Department of Civil and Environmental Engineering, University of California, Berkeley, CA, USA,Blum Center for Developing Economies, University of California, Berkeley, CA, USA,Correspondence and requests for materials should be addressed to Dr. Amy Pickering () and Dr. Tim Julian ()
| |
Collapse
|
24
|
Gu G, Kroft B, Lichtenwald M, Luo Y, Millner P, Patel J, Nou X. Dynamics of Listeria monocytogenes and the microbiome on fresh-cut cantaloupe and romaine lettuce during storage at refrigerated and abusive temperatures. Int J Food Microbiol 2022; 364:109531. [PMID: 35033975 DOI: 10.1016/j.ijfoodmicro.2022.109531] [Citation(s) in RCA: 6] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/30/2021] [Revised: 12/09/2021] [Accepted: 01/03/2022] [Indexed: 12/25/2022]
Abstract
Listeria monocytogenes (Lm) outbreaks and recalls associated with fresh produce in recent years have heightened concerns and demands from industry and consumers to more effectively mitigate the contamination risk of this foodborne pathogen on fresh produce. In this study, the growth of Lm and indigenous bacteria on fresh-cut cantaloupe and romaine lettuce held at refrigerated (4 °C) and abusive (10-24 °C) temperatures was determined by both culture dependent and independent methods. Composition and dynamics of bacterial communities on Lm inoculated and non-inoculated samples were analyzed by 16S rRNA high-throughput sequencing. Fresh-cut cantaloupe provided favorable growth conditions for Lm proliferation (1.7 and >6 log increase at refrigerated and abusive temperatures, respectively) to overtake indigenous bacteria. The Lm population also increased on fresh-cut lettuce, but the growth rate was lower than that of the total mesophilic bacteria, resulting in 0.4 and >2 log increase at refrigerated and abusive temperatures. Microbial diversity of fresh-cut cantaloupe was significantly lower than that of fresh-cut romaine lettuce. The Shannon index of microbial communities on cantaloupe declined after storage, but it was not significantly changed on lettuce samples. Shifts in the bacterial microbiome on cantaloupe were mainly affected by Lm inoculation, while both inoculation and storage temperature played significant roles on lettuce bacterial communities. Multiple indigenous bacteria, including Leuconostoc and Weissella spp., were negatively correlated to Lm abundance on romaine lettuce, and were determined by bioassay as potential anti-listerial species. Data derived from this study contribute to better understanding of the relationship between Lm and indigenous microbiota on fresh-cut produce during storage.
Collapse
Affiliation(s)
- Ganyu Gu
- Environmental Microbial and Food Safety Laboratory, USDA ARS, Beltsville, MD 20705, USA
| | - Brenda Kroft
- Centre for Food Safety and Security Systems, University of Maryland, College Park, MD 20742, USA
| | - Marina Lichtenwald
- Environmental Microbial and Food Safety Laboratory, USDA ARS, Beltsville, MD 20705, USA
| | - Yaguang Luo
- Environmental Microbial and Food Safety Laboratory, USDA ARS, Beltsville, MD 20705, USA
| | - Patricia Millner
- Environmental Microbial and Food Safety Laboratory, USDA ARS, Beltsville, MD 20705, USA
| | - Jitendra Patel
- Environmental Microbial and Food Safety Laboratory, USDA ARS, Beltsville, MD 20705, USA
| | - Xiangwu Nou
- Environmental Microbial and Food Safety Laboratory, USDA ARS, Beltsville, MD 20705, USA.
| |
Collapse
|
25
|
Mao G, Wang Y, Hammes F. Automated flow cytometry as a flexible tool for comparing disinfection characteristics of indigenous bacterial communities and pure cultures. ECOTOXICOLOGY AND ENVIRONMENTAL SAFETY 2021; 225:112799. [PMID: 34555718 DOI: 10.1016/j.ecoenv.2021.112799] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 04/22/2021] [Revised: 08/23/2021] [Accepted: 09/15/2021] [Indexed: 06/13/2023]
Abstract
Bacterial inactivation efficiency of chlorine varies with organisms and environmental conditions. The comparability of different samples/studies, especially comparing indigenous bacterial communities with pure cultures, is impeded by inconsistent experimental conditions and analytical methods used in various studies. We tested a novel 96-well plate FCM experimental and automated analytical approach, where bacterial communities and pure cultures were suspended in the same natural water matrix prior to chlorination directly in the plate. We demonstrated the ability to rapidly monitor the efficiency of 32 different combinations of chlorine concentration and time (i.e. chlorine exposure) on bacterial pure cultures and indigenous aquatic communities, which enabled correct comparison of the data from different samples under the exact same experimental conditions. In this study, the 96-well plate automated FCM approach enabled large sets (896) of independent chlorination experiments to be carried out in a short time period. To our knowledge, this is the largest dataset of chlorination experiments which consumed least time (within 18 h after sampling) until now. Staining with SYBR Green I (SG) and SG combined with propidium iodide (SGPI) was used to assess cellular damage during chlorination. The results showed that with the same chlorine exposure, a higher chlorine concentration with a shorter contact time is favorable for inactivation of bacteria. Our research provides a promising framework to compare disinfection characteristics of various microorganism and can be further developed to diagnose effect of antimicrobial products.
Collapse
Affiliation(s)
- Guannan Mao
- Key Laboratory of Pollution Processes and Environmental Criteria (Ministry of Education), Tianjin Key Laboratory of Environmental Remediation and Pollution Control, College of Environmental Science and Engineering, Nankai University, Tianjin 300071, China; Department of Environmental Microbiology, Eawag: Swiss Federal Institute of Aquatic Science and Technology, Dübendorf 8600, Switzerland; State Key Laboratory of Tibetan Plateau Earth System, Resources and Environment (TPESRE), Institute of Tibetan Plateau Research, Chinese Academy of Sciences, Beijing 100101, China
| | - Yingying Wang
- Key Laboratory of Pollution Processes and Environmental Criteria (Ministry of Education), Tianjin Key Laboratory of Environmental Remediation and Pollution Control, College of Environmental Science and Engineering, Nankai University, Tianjin 300071, China.
| | - Frederik Hammes
- Department of Environmental Microbiology, Eawag: Swiss Federal Institute of Aquatic Science and Technology, Dübendorf 8600, Switzerland.
| |
Collapse
|
26
|
Extracellular DNA in environmental samples: Occurrence, extraction, quantification, and impact on microbial biodiversity assessment. Appl Environ Microbiol 2021; 88:e0184521. [PMID: 34818108 DOI: 10.1128/aem.01845-21] [Citation(s) in RCA: 11] [Impact Index Per Article: 2.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/20/2022] Open
Abstract
Environmental DNA, i.e., DNA directly extracted from environmental samples, has been applied to understand microbial communities in the environments and to monitor contemporary biodiversity in the conservation context. Environmental DNA often contains both intracellular DNA (iDNA) and extracellular DNA (eDNA). eDNA can persist in the environment and complicate environmental DNA sequencing-based analyses of microbial communities and biodiversity. Although several studies acknowledged the impact of eDNA on DNA-based profiling of environmental communities, eDNA is still being neglected or ignored in most studies dealing with environmental samples. In this article, we summarize key findings on eDNA in environmental samples and discuss the methods used to extract and quantify eDNA as well as the importance of eDNA on the interpretation of experimental results. We then suggest several factors to consider when designing experiments and analyzing data to negate or determine the contribution of eDNA to environmental DNA-based community analyses. This field of research will be driven forward by: (i) carefully designing environmental DNA extraction pipelines by taking into consideration technical details in methods for eDNA extraction/removal and membrane-based filtration and concentration; (ii) quantifying eDNA in extracted environmental DNA using multiple methods including qPCR and fluorescent DNA binding dyes; (iii) carefully interpretating effect of eDNA on DNA-based community analyses at different taxonomic levels; and (iv) when possible, removing eDNA from environmental samples for DNA-based community analyses.
Collapse
|
27
|
Zhang C, Lu J. Legionella: A Promising Supplementary Indicator of Microbial Drinking Water Quality in Municipal Engineered Water Systems. FRONTIERS IN ENVIRONMENTAL SCIENCE 2021; 9:1-22. [PMID: 35004706 PMCID: PMC8740890 DOI: 10.3389/fenvs.2021.684319] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/06/2023]
Abstract
Opportunistic pathogens (OPs) are natural inhabitants and the predominant disease causative biotic agents in municipal engineered water systems (EWSs). In EWSs, OPs occur at high frequencies and concentrations, cause drinking-water-related disease outbreaks, and are a major factor threatening public health. Therefore, the prevalence of OPs in EWSs represents microbial drinking water quality. Closely or routinely monitoring the dynamics of OPs in municipal EWSs is thus critical to ensuring drinking water quality and protecting public health. Monitoring the dynamics of conventional (fecal) indicators (e.g., total coliforms, fecal coliforms, and Escherichia coli) is the customary or even exclusive means of assessing microbial drinking water quality. However, those indicators infer only fecal contamination due to treatment (e.g., disinfection within water utilities) failure and EWS infrastructure issues (e.g., water main breaks and infiltration), whereas OPs are not contaminants in drinking water. In addition, those indicators appear in EWSs at low concentrations (often absent in well-maintained EWSs) and are uncorrelated with OPs. For instance, conventional indicators decay, while OPs regrow with increasing hydraulic residence time. As a result, conventional indicators are poor indicators of OPs (the major aspect of microbial drinking water quality) in EWSs. An additional or supplementary indicator that can well infer the prevalence of OPs in EWSs is highly needed. This systematic review argues that Legionella as a dominant OP-containing genus and natural inhabitant in EWSs is a promising candidate for such a supplementary indicator. Through comprehensively comparing the behavior (i.e., occurrence, growth and regrowth, spatiotemporal variations in concentrations, resistance to disinfectant residuals, and responses to physicochemical water quality parameters) of major OPs (e.g., Legionella especially L. pneumophila, Mycobacterium, and Pseudomonas especially P. aeruginosa), this review proves that Legionella is a promising supplementary indicator for the prevalence of OPs in EWSs while other OPs lack this indication feature. Legionella as a dominant natural inhabitant in EWSs occurs frequently, has a high concentration, and correlates with more microbial and physicochemical water quality parameters than other common OPs. Legionella and OPs in EWSs share multiple key features such as high disinfectant resistance, biofilm formation, proliferation within amoebae, and significant spatiotemporal variations in concentrations. Therefore, the presence and concentration of Legionella well indicate the presence and concentrations of OPs (especially L. pneumophila) and microbial drinking water quality in EWSs. In addition, Legionella concentration indicates the efficacies of disinfectant residuals in EWSs. Furthermore, with the development of modern Legionella quantification methods (especially quantitative polymerase chain reactions), monitoring Legionella in ESWs is becoming easier, more affordable, and less labor-intensive. Those features make Legionella a proper supplementary indicator for microbial drinking water quality (especially the prevalence of OPs) in EWSs. Water authorities may use Legionella and conventional indicators in combination to more comprehensively assess microbial drinking water quality in municipal EWSs. Future work should further explore the indication role of Legionella in EWSs and propose drinking water Legionella concentration limits that indicate serious public health effects and require enhanced treatment (e.g., booster disinfection).
Collapse
Affiliation(s)
- Chiqian Zhang
- Pegasus Technical Services, Inc., Cincinnati, OH, United States
| | - Jingrang Lu
- Office of Research and Development, United States Environmental Protection Agency, Cincinnati, OH, United States
| |
Collapse
|
28
|
Han Z, Lu J, An W, Zhang Y, Yang M. Removal efficacy of opportunistic pathogen gene markers in drinking water supply systems: an in situ and large-scale molecular investigation. ENVIRONMENTAL SCIENCE AND POLLUTION RESEARCH INTERNATIONAL 2021; 28:54153-54160. [PMID: 34389952 DOI: 10.1007/s11356-021-15744-y] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 03/25/2021] [Accepted: 07/27/2021] [Indexed: 06/13/2023]
Abstract
The prevalence and interactions with biofilm and disinfectant of opportunistic pathogens in drinking water supply systems (DWSSs) have been extensively interpreted. In contrast, the large geographical distribution and in situ removal of opportunistic pathogens are overlooked aspects. Here, paired source and tap water samples of 36 parallel DWSSs across China were collected, with five common waterborne pathogens characterized by qPCR. From source to tap, the removal of bacterial biomass (16S rRNA gene copy number) was 1.10 log, and gene marker removal of five opportunistic pathogens ranged from 0.66 log to 2.27 log, with the order of Escherichia coli > Mycobacterium spp. > Clostridium perfringens > Bacillus cereus > Aeromonas hydrophila. Different with bacterial community, geographical location and source water types (river or reservoir) were not key contributor to variation of opportunistic pathogens. Gene marker removal efficacies of E. coli, Mycobacterium spp., and C. perfringens from source to tap were restricted to removal efficacy of overall bacterial biomass, while abundance of B. cereus in tap water linked to the input of B. cereus from source water. Although culture-dependent approach is important for pathogen enumeration in drinking water, qPCR-based molecular survey shows advantages of quantifiable high-throughput and easy operation, providing abundant and timely information on pathogen occurrence in water. This study provides the in situ, molecular-level evidence toward differential propagation features of multiple opportunistic pathogens in DWSSs and suggests the source protection and early warning of treatment-resistant pathogens.
Collapse
Affiliation(s)
- Ziming Han
- State Key Laboratory of Environmental Aquatic Chemistry, Research Center for Eco-Environmental Sciences, Chinese Academy of Sciences, Beijing, 100085, China
- University of Chinese Academy of Sciences, Beijing, 100049, China
| | - Junying Lu
- State Key Laboratory of Environmental Aquatic Chemistry, Research Center for Eco-Environmental Sciences, Chinese Academy of Sciences, Beijing, 100085, China
| | - Wei An
- Key Laboratory of Drinking Water Science and Technology, Research Center for Eco-Environmental Sciences, Chinese Academy of Sciences, Beijing, 100085, China
| | - Yu Zhang
- State Key Laboratory of Environmental Aquatic Chemistry, Research Center for Eco-Environmental Sciences, Chinese Academy of Sciences, Beijing, 100085, China.
- University of Chinese Academy of Sciences, Beijing, 100049, China.
| | - Min Yang
- University of Chinese Academy of Sciences, Beijing, 100049, China.
- Key Laboratory of Drinking Water Science and Technology, Research Center for Eco-Environmental Sciences, Chinese Academy of Sciences, Beijing, 100085, China.
| |
Collapse
|
29
|
Wang HB, Wu YH, Luo LW, Yu T, Xu A, Xue S, Chen GQ, Ni XY, Peng L, Chen Z, Wang YH, Tong X, Bai Y, Xu YQ, Hu HY. Risks, characteristics, and control strategies of disinfection-residual-bacteria (DRB) from the perspective of microbial community structure. WATER RESEARCH 2021; 204:117606. [PMID: 34500181 PMCID: PMC8390064 DOI: 10.1016/j.watres.2021.117606] [Citation(s) in RCA: 41] [Impact Index Per Article: 10.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 04/25/2021] [Revised: 08/19/2021] [Accepted: 08/23/2021] [Indexed: 05/19/2023]
Abstract
The epidemic of COVID-19 has aroused people's particular attention to biosafety. A growing number of disinfection products have been consumed during this period. However, the flaw of disinfection has not received enough attention, especially in water treatment processes. While cutting down the quantity of microorganisms, disinfection processes exert a considerable selection effect on bacteria and thus reshape the microbial community structure to a great extent, causing the problem of disinfection-residual-bacteria (DRB). These systematic and profound changes could lead to the shift in regrowth potential, bio fouling potential, as well as antibiotic resistance level and might cause a series of potential risks. In this review, we collected and summarized the data from the literature in recent 10 years about the microbial community structure shifting of natural water or wastewater in full-scale treatment plants caused by disinfection. Based on these data, typical DRB with the most reporting frequency after disinfection by chlorine-containing disinfectants, ozone disinfection, and ultraviolet disinfection were identified and summarized, which were the bacteria with a relative abundance of over 5% in the residual bacteria community and the bacteria with an increasing rate of relative abundance over 100% after disinfection. Furthermore, the phylogenic relationship and potential risks of these typical DRB were also analyzed. Twelve out of fifteen typical DRB genera contain pathogenic strains, and many were reported of great secretion ability. Pseudomonas and Acinetobacter possess multiple disinfection resistance and could be considered as model bacteria in future studies of disinfection. We also discussed the growth, secretion, and antibiotic resistance characteristics of DRB, as well as possible control strategies. The DRB phenomenon is not limited to water treatment but also exists in the air and solid disinfection processes, which need more attention and more profound research, especially in the period of COVID-19.
Collapse
Affiliation(s)
- Hao-Bin Wang
- Environmental Simulation and Pollution Control State Key Joint Laboratory, State Environmental Protection Key Laboratory of Microorganism Application and Risk Control (SMARC), School of Environment, Tsinghua University, Room 524, Beijing 100084, PR China; Beijing Laboratory for Environmental Frontier Technologies, Beijing 100084, PR China
| | - Yin-Hu Wu
- Environmental Simulation and Pollution Control State Key Joint Laboratory, State Environmental Protection Key Laboratory of Microorganism Application and Risk Control (SMARC), School of Environment, Tsinghua University, Room 524, Beijing 100084, PR China; Beijing Laboratory for Environmental Frontier Technologies, Beijing 100084, PR China.
| | - Li-Wei Luo
- Environmental Simulation and Pollution Control State Key Joint Laboratory, State Environmental Protection Key Laboratory of Microorganism Application and Risk Control (SMARC), School of Environment, Tsinghua University, Room 524, Beijing 100084, PR China; Beijing Laboratory for Environmental Frontier Technologies, Beijing 100084, PR China
| | - Tong Yu
- School of Environmental and Municipal Engineering, Qingdao University of Technology, Qingdao 266000, PR China
| | - Ao Xu
- Environmental Simulation and Pollution Control State Key Joint Laboratory, State Environmental Protection Key Laboratory of Microorganism Application and Risk Control (SMARC), School of Environment, Tsinghua University, Room 524, Beijing 100084, PR China; Beijing Laboratory for Environmental Frontier Technologies, Beijing 100084, PR China; Research Institute for Environmental Innovation (Suzhou), Tsinghua, Suzhou Jiangsu 215163, PR China
| | - Song Xue
- Environmental Simulation and Pollution Control State Key Joint Laboratory, State Environmental Protection Key Laboratory of Microorganism Application and Risk Control (SMARC), School of Environment, Tsinghua University, Room 524, Beijing 100084, PR China; Beijing Laboratory for Environmental Frontier Technologies, Beijing 100084, PR China
| | - Gen-Qiang Chen
- Environmental Simulation and Pollution Control State Key Joint Laboratory, State Environmental Protection Key Laboratory of Microorganism Application and Risk Control (SMARC), School of Environment, Tsinghua University, Room 524, Beijing 100084, PR China; Beijing Laboratory for Environmental Frontier Technologies, Beijing 100084, PR China
| | - Xin-Ye Ni
- Environmental Simulation and Pollution Control State Key Joint Laboratory, State Environmental Protection Key Laboratory of Microorganism Application and Risk Control (SMARC), School of Environment, Tsinghua University, Room 524, Beijing 100084, PR China; Beijing Laboratory for Environmental Frontier Technologies, Beijing 100084, PR China
| | - Lu Peng
- Shenzhen Environmental Science and New Energy Technology Engineering Laboratory, Tsinghua-Berkeley Shenzhen Institute, Shenzhen 518055, PR China
| | - Zhuo Chen
- Environmental Simulation and Pollution Control State Key Joint Laboratory, State Environmental Protection Key Laboratory of Microorganism Application and Risk Control (SMARC), School of Environment, Tsinghua University, Room 524, Beijing 100084, PR China; Beijing Laboratory for Environmental Frontier Technologies, Beijing 100084, PR China
| | - Yun-Hong Wang
- Environmental Simulation and Pollution Control State Key Joint Laboratory, State Environmental Protection Key Laboratory of Microorganism Application and Risk Control (SMARC), School of Environment, Tsinghua University, Room 524, Beijing 100084, PR China; Beijing Laboratory for Environmental Frontier Technologies, Beijing 100084, PR China
| | - Xin Tong
- Environmental Simulation and Pollution Control State Key Joint Laboratory, State Environmental Protection Key Laboratory of Microorganism Application and Risk Control (SMARC), School of Environment, Tsinghua University, Room 524, Beijing 100084, PR China; Beijing Laboratory for Environmental Frontier Technologies, Beijing 100084, PR China
| | - Yuan Bai
- Environmental Simulation and Pollution Control State Key Joint Laboratory, State Environmental Protection Key Laboratory of Microorganism Application and Risk Control (SMARC), School of Environment, Tsinghua University, Room 524, Beijing 100084, PR China; Beijing Laboratory for Environmental Frontier Technologies, Beijing 100084, PR China
| | - Yu-Qing Xu
- Environmental Simulation and Pollution Control State Key Joint Laboratory, State Environmental Protection Key Laboratory of Microorganism Application and Risk Control (SMARC), School of Environment, Tsinghua University, Room 524, Beijing 100084, PR China; Beijing Laboratory for Environmental Frontier Technologies, Beijing 100084, PR China
| | - Hong-Ying Hu
- Environmental Simulation and Pollution Control State Key Joint Laboratory, State Environmental Protection Key Laboratory of Microorganism Application and Risk Control (SMARC), School of Environment, Tsinghua University, Room 524, Beijing 100084, PR China; Beijing Laboratory for Environmental Frontier Technologies, Beijing 100084, PR China; Shenzhen Environmental Science and New Energy Technology Engineering Laboratory, Tsinghua-Berkeley Shenzhen Institute, Shenzhen 518055, PR China.
| |
Collapse
|
30
|
Santos ASGG, Ramalho PSF, Viana AT, Lopes AR, Gonçalves AG, Nunes OC, Pereira MFR, Soares OSGP. Feasibility of using magnetic nanoparticles in water disinfection. JOURNAL OF ENVIRONMENTAL MANAGEMENT 2021; 288:112410. [PMID: 33831640 DOI: 10.1016/j.jenvman.2021.112410] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 11/27/2020] [Revised: 03/03/2021] [Accepted: 03/16/2021] [Indexed: 06/12/2023]
Abstract
Disinfection is a crucial step during the water treatment process due to the significant risks of water contamination with human and animal excreta. The development of innovative disinfection technologies that can be applied at water point of use, avoiding contamination problems in water distribution systems and reservoirs, are needed. Thus, the present work aimed at assessing the disinfection efficiency of iron oxide magnetic nanoparticles (MNPs) modified with different compounds, such as carbon nanotubes, copper and silver, in water solutions contaminated with bacteria. Kinetic and influence of nanoparticles concentration experiments, performed with Escherichia coli, allowed to define the optimal reaction conditions to apply in batch experiments (1 min of contact time and 50 mg/mL of MNPs). During these experiments, CuFeO/CNT, C-FeO@CVD750 and 5% Ag/FeO were selected as the most efficient presenting log reduction values of 2.99, 1.50 and 2.11, respectively; however, experiments performed with Staphylococcus aureus suspension and a mixed bacterial suspension (E. coli + S. aureus) allowed to observe a slight decrease in nanomaterials efficiency, which was more evident for C-FeO@CVD750 and 5% Ag/FeO materials achieving efficiencies of 94 and 83% (corresponding log reductions of 1.26 and 0.77, respectively). CuFeO/CNT nanoparticles proved to be the most efficient material for both bacteria removal presenting an efficiency of 99% (corresponding log reduction of 1.99) for the mixed bacterial suspension. These nanoparticles proved to have great stability over successive experiments, and the low leaching values of the metals present in their composition after reaction proved the resistance and efficiency of these magnetic nanoparticles.
Collapse
Affiliation(s)
- A Sofia G G Santos
- Associate Laboratory LSRE-LCM, Departamento de Engenharia Química, Faculdade de Engenharia, Universidade do Porto, 4200-465, Porto, Portugal; LEPABE - Laboratory for Process Engineering, Environment, Biotechnology and Energy (LEPABE), Departamento de Engenharia Química, Faculdade de Engenharia, Universidade do Porto, 4200-465, Porto, Portugal
| | - Patrícia S F Ramalho
- Associate Laboratory LSRE-LCM, Departamento de Engenharia Química, Faculdade de Engenharia, Universidade do Porto, 4200-465, Porto, Portugal
| | - A T Viana
- LEPABE - Laboratory for Process Engineering, Environment, Biotechnology and Energy (LEPABE), Departamento de Engenharia Química, Faculdade de Engenharia, Universidade do Porto, 4200-465, Porto, Portugal
| | - A R Lopes
- LEPABE - Laboratory for Process Engineering, Environment, Biotechnology and Energy (LEPABE), Departamento de Engenharia Química, Faculdade de Engenharia, Universidade do Porto, 4200-465, Porto, Portugal
| | | | - Olga C Nunes
- LEPABE - Laboratory for Process Engineering, Environment, Biotechnology and Energy (LEPABE), Departamento de Engenharia Química, Faculdade de Engenharia, Universidade do Porto, 4200-465, Porto, Portugal
| | - M Fernando R Pereira
- Associate Laboratory LSRE-LCM, Departamento de Engenharia Química, Faculdade de Engenharia, Universidade do Porto, 4200-465, Porto, Portugal
| | - O Salomé G P Soares
- Associate Laboratory LSRE-LCM, Departamento de Engenharia Química, Faculdade de Engenharia, Universidade do Porto, 4200-465, Porto, Portugal.
| |
Collapse
|
31
|
Ng WJ, Tan CT, Bae S. Effects of monochloramine on culturability, viability and persistence of Pseudomonas putida and tap water mixed bacterial community. Appl Microbiol Biotechnol 2021; 105:3799-3810. [PMID: 33885926 DOI: 10.1007/s00253-021-11251-9] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/08/2020] [Revised: 02/18/2021] [Accepted: 03/21/2021] [Indexed: 11/26/2022]
Abstract
Bacterial biofilms are able to persist in drinking water distribution systems (DWDS) even if disinfectants such as monochloramine are used to inhibit bacterial colonization and biofilm formation. While studies have determined the monochloramine concentrations required to inhibit bacterial biofilms, not much is known about how bacterial biofilms develop resistance towards monochloramine. This study covers the development of resistance to monochloramine in both single species and mixed bacterial biofilms. Through culturability tests and flow cytometry, exposing bacterial biofilms to monochloramine disinfection using a sub-lethal concentration (1.5 mg/L Cl2, experimentally determined) was sufficient to cause an increase of the monochloramine's inhibitory concentrations by as much as two times than what is initially required to inhibit biofilm growth. Through persister cultures and 16S rRNA next generation sequencing (NGS) studies, mixed bacterial biofilms experienced to monochloramine exposure resulted in more bacterial genera becoming persistent and resistant towards monochloramine. Through this study, bacterial genera that were persistent towards monochloramine were suggested to share common traits including the ability (1) to readily enter a persister or viable but non-culturable (VBNC) state and (2) to form biofilms primarily comprising proteinaceous extra-polymeric substances (EPS). Both of these traits also suggested that selected bacterial genera tended to be more persistent to monochloramine and produce EPS. This study advances our understanding of bacterial biofilm resistance towards monochloramine and showed the importance of maintaining monochloramine concentrations in DWDS to prevent the development of bacterial resistance towards monochloramine. KEY POINTS: • Monochloramine-resistant biofilm was developed after sub-lethal disinfection. • Mixed-species culture experienced monochloramine showed more persistence to monochloramine. • Ability to enter a persister/VBNC state is a common trait of persistent bacteria genera.
Collapse
Affiliation(s)
- Wei Jie Ng
- Department of Civil and Environmental Engineering, National University of Singapore, 1 Engineering Drive 2, #07-03 E1A, Singapore, 117576, Singapore
| | - Ching Thong Tan
- Department of Civil and Environmental Engineering, National University of Singapore, 1 Engineering Drive 2, #07-03 E1A, Singapore, 117576, Singapore
| | - Sungwoo Bae
- Department of Civil and Environmental Engineering, National University of Singapore, 1 Engineering Drive 2, #07-03 E1A, Singapore, 117576, Singapore.
| |
Collapse
|
32
|
Garner E, Davis BC, Milligan E, Blair MF, Keenum I, Maile-Moskowitz A, Pan J, Gnegy M, Liguori K, Gupta S, Prussin AJ, Marr LC, Heath LS, Vikesland PJ, Zhang L, Pruden A. Next generation sequencing approaches to evaluate water and wastewater quality. WATER RESEARCH 2021; 194:116907. [PMID: 33610927 DOI: 10.1016/j.watres.2021.116907] [Citation(s) in RCA: 56] [Impact Index Per Article: 14.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 10/26/2020] [Revised: 01/15/2021] [Accepted: 02/03/2021] [Indexed: 05/24/2023]
Abstract
The emergence of next generation sequencing (NGS) is revolutionizing the potential to address complex microbiological challenges in the water industry. NGS technologies can provide holistic insight into microbial communities and their functional capacities in water and wastewater systems, thus eliminating the need to develop a new assay for each target organism or gene. However, several barriers have hampered wide-scale adoption of NGS by the water industry, including cost, need for specialized expertise and equipment, challenges with data analysis and interpretation, lack of standardized methods, and the rapid pace of development of new technologies. In this critical review, we provide an overview of the current state of the science of NGS technologies as they apply to water, wastewater, and recycled water. In addition, a systematic literature review was conducted in which we identified over 600 peer-reviewed journal articles on this topic and summarized their contributions to six key areas relevant to the water and wastewater fields: taxonomic classification and pathogen detection, functional and catabolic gene characterization, antimicrobial resistance (AMR) profiling, bacterial toxicity characterization, Cyanobacteria and harmful algal bloom identification, and virus characterization. For each application, we have presented key trends, noteworthy advancements, and proposed future directions. Finally, key needs to advance NGS technologies for broader application in water and wastewater fields are assessed.
Collapse
Affiliation(s)
- Emily Garner
- Wadsworth Department of Civil and Environmental Engineering, West Virginia University, 1306 Evansdale Drive, Morgantown, WV 26505, United States.
| | - Benjamin C Davis
- Charles E. Via, Jr. Department of Civil and Environmental Engineering, Virginia Tech, 1145 Perry Street, Blacksburg, VA 24061, United States
| | - Erin Milligan
- Charles E. Via, Jr. Department of Civil and Environmental Engineering, Virginia Tech, 1145 Perry Street, Blacksburg, VA 24061, United States
| | - Matthew Forrest Blair
- Charles E. Via, Jr. Department of Civil and Environmental Engineering, Virginia Tech, 1145 Perry Street, Blacksburg, VA 24061, United States
| | - Ishi Keenum
- Charles E. Via, Jr. Department of Civil and Environmental Engineering, Virginia Tech, 1145 Perry Street, Blacksburg, VA 24061, United States
| | - Ayella Maile-Moskowitz
- Charles E. Via, Jr. Department of Civil and Environmental Engineering, Virginia Tech, 1145 Perry Street, Blacksburg, VA 24061, United States
| | - Jin Pan
- Charles E. Via, Jr. Department of Civil and Environmental Engineering, Virginia Tech, 1145 Perry Street, Blacksburg, VA 24061, United States
| | - Mariah Gnegy
- Charles E. Via, Jr. Department of Civil and Environmental Engineering, Virginia Tech, 1145 Perry Street, Blacksburg, VA 24061, United States
| | - Krista Liguori
- Charles E. Via, Jr. Department of Civil and Environmental Engineering, Virginia Tech, 1145 Perry Street, Blacksburg, VA 24061, United States
| | - Suraj Gupta
- The Interdisciplinary PhD Program in Genetics, Bioinformatics, and Computational Biology, Virginia Tech, Blacksburg, VA 24061, United States
| | - Aaron J Prussin
- Charles E. Via, Jr. Department of Civil and Environmental Engineering, Virginia Tech, 1145 Perry Street, Blacksburg, VA 24061, United States
| | - Linsey C Marr
- Charles E. Via, Jr. Department of Civil and Environmental Engineering, Virginia Tech, 1145 Perry Street, Blacksburg, VA 24061, United States
| | - Lenwood S Heath
- Department of Computer Science, Virginia Tech, 225 Stranger Street, Blacksburg, VA 24061, United States
| | - Peter J Vikesland
- Charles E. Via, Jr. Department of Civil and Environmental Engineering, Virginia Tech, 1145 Perry Street, Blacksburg, VA 24061, United States
| | - Liqing Zhang
- Department of Computer Science, Virginia Tech, 225 Stranger Street, Blacksburg, VA 24061, United States
| | - Amy Pruden
- Charles E. Via, Jr. Department of Civil and Environmental Engineering, Virginia Tech, 1145 Perry Street, Blacksburg, VA 24061, United States.
| |
Collapse
|
33
|
Guo L, Wan K, Zhu J, Ye C, Chabi K, Yu X. Detection and distribution of vbnc/viable pathogenic bacteria in full-scale drinking water treatment plants. JOURNAL OF HAZARDOUS MATERIALS 2021; 406:124335. [PMID: 33160785 DOI: 10.1016/j.jhazmat.2020.124335] [Citation(s) in RCA: 33] [Impact Index Per Article: 8.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 08/11/2020] [Revised: 10/15/2020] [Accepted: 10/16/2020] [Indexed: 05/22/2023]
Abstract
Viable but non-culturable (VBNC) bacteria have attracted widespread attention since they are inherently undetected by traditional culture-dependent methods. Importantly, VBNC bacteria could resuscitate under favorable conditions leading to significant public health concerns. Although the total number of viable bacteria has been theorized to be far greater than those that can be cultured, there have been no reports quantifying VBNC pathogenic bacteria in full-scale drinking water treatment plants (DWTPs). In this work, we used both culture-dependent and quantitative PCR combination with propidium monoazide (PMA) dye approaches to characterize cellular viability. Further, we established a method to quantify viable pathogens by relating specific gene copies to viable cell numbers. Ratios of culturable bacteria to viable 16S rRNA gene copies in water and biological activated carbon (BAC) biofilms were 0-4.75% and 0.04-56.24%, respectively. The VBNC E. coli, E. faecalis, P. aeruginosa, Salmonella sp., and Shigella sp. were detected at levels of 0-103 cells/100 mL in source water, 0-102 cells/100 mL in chlorinated water, and 0-103 cells/g in BAC biofilms. In addition, differences between the total and viable community structures after ozonation and chlorination were investigated. The relative abundance of opportunistic pathogens such as Mycobacterium, Sphingomonas, etc. increased in final water, likely due to their chlorine resistance. In summary, we detected significant quantities of viable/VBNC opportunistic pathogens in full-scale DWTPs, confirming that traditional, culture-dependent methods are inadequate for detecting VBNC bacteria. These findings suggest a need to develop and implement rapid, accurate methods for the detection of VBNC pathogenic bacteria in DWTPs to ensure the safety of drinking water.
Collapse
Affiliation(s)
- Lizheng Guo
- Key Lab of Urban Environment and Health, Institute of Urban Environment, Chinese Academy of Sciences, Xiamen 361021, China; University of Chinese Academy of Sciences, Beijing 100049, China
| | - Kun Wan
- Key Lab of Urban Environment and Health, Institute of Urban Environment, Chinese Academy of Sciences, Xiamen 361021, China; University of Chinese Academy of Sciences, Beijing 100049, China
| | | | - Chengsong Ye
- College of Environment & Ecology, Xiamen University, Xiamen 361102, China
| | - Kassim Chabi
- Key Lab of Urban Environment and Health, Institute of Urban Environment, Chinese Academy of Sciences, Xiamen 361021, China; University of Chinese Academy of Sciences, Beijing 100049, China
| | - Xin Yu
- Key Lab of Urban Environment and Health, Institute of Urban Environment, Chinese Academy of Sciences, Xiamen 361021, China; College of Environment & Ecology, Xiamen University, Xiamen 361102, China.
| |
Collapse
|
34
|
SIEDLECKA AGATA, WOLF-BACA MIRELAJ, PIEKARSKA KATARZYNA. Antibiotic and Disinfectant Resistance in Tap Water Strains - Insight into the Resistance of Environmental Bacteria. Pol J Microbiol 2021; 70:57-67. [PMID: 33815527 PMCID: PMC8008766 DOI: 10.33073/pjm-2021-004] [Citation(s) in RCA: 13] [Impact Index Per Article: 3.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/24/2020] [Revised: 12/30/2020] [Accepted: 01/11/2021] [Indexed: 12/15/2022] Open
Abstract
Although antibiotic-resistant bacteria (ARB) have been isolated from tap water worldwide, the knowledge of their resistance patterns is still scarce. Both horizontal and vertical gene transfer has been suggested to contribute to the resistance spread among tap water bacteria. In this study, ARB were isolated from finished water collected at two independent water treatment plants (WTPs) and tap water collected at several point-of-use taps during summer and winter sampling campaigns. A total of 24 strains were identified to genus or species level and subjected to antibiotic and disinfectant susceptibility testing. The investigated tap water ARB belonged to phyla Proteobacteria, Bacteroidetes, Actinobacteria, and Firmicutes. The majority of the isolates proved multidrug resistant and resistant to chemical disinfectant. Neither seasonal nor WTP-dependent variabilities in antibiotic or disinfectant resistance were found. Antibiotics most effective against the investigated isolates included imipenem, tetracyclines, erythromycin, and least effective - aztreonam, cefotaxime, amoxicillin, and ceftazidime. The most resistant strains originate from Afipia sp. and Methylobacterium sp. Comparing resistance patterns of isolated tap water ARB with literature reports concerning the same genera or species confirms intra-genus or even intra-specific variabilities of environmental bacteria. Neither species-specific nor acquired resistance can be excluded.
Collapse
Affiliation(s)
- AGATA SIEDLECKA
- Department of Environmental Protection Engineering, Faculty of Environmental Engineering, Wrocław University of Science and Technology, Wrocław, Poland
| | - MIRELA J. WOLF-BACA
- Department of Environmental Protection Engineering, Faculty of Environmental Engineering, Wrocław University of Science and Technology, Wrocław, Poland
| | - KATARZYNA PIEKARSKA
- Department of Environmental Protection Engineering, Faculty of Environmental Engineering, Wrocław University of Science and Technology, Wrocław, Poland
| |
Collapse
|
35
|
Song P, Xiao Y, Ren ZJ, Brooks JP, Lu L, Zhou B, Zhou Y, Freguia S, Liu Z, Zhang N, Li Y. Electrochemical biofilm control by reconstructing microbial community in agricultural water distribution systems. JOURNAL OF HAZARDOUS MATERIALS 2021; 403:123616. [PMID: 32781280 DOI: 10.1016/j.jhazmat.2020.123616] [Citation(s) in RCA: 11] [Impact Index Per Article: 2.8] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 05/13/2020] [Revised: 07/10/2020] [Accepted: 07/26/2020] [Indexed: 05/14/2023]
Abstract
Biofilm causes considerable technical challenges in agricultural water distribution systems. Electrochemical treatment (ECT) is a potential technique for controlling biofilm in the systems. Given the limited information on how ECT performance changes of irrigation systems and microbial biofilm community shifts. In this study, the effect of anti-biofilm was assessed. Illumina Miseq high-throughput sequencing, combined with molecular ecological network analysis, were applied to detect the effects of ECT on attached biofilm microbial communities. We found that ECT effectively mitigated biofilm formation with the fixed-biofilm biomass reduced by 37.5 %-79.9 %. ECT significantly shifted the bacterial community structures in the biofilm, reduced the communities' diversity, and changed the dominant species. Molecular ecological network analysis showed that the complexity and size of bacterial networks were destabilized under ECT and decreased the interactions among bacterial species. The reconstruction in bacterial community and networks were responsible for the decline in extracellular polymer substances and biofilm biomass. However, chlorine-resistant bacteria were found increased after ECT, and higher relative abundance and low biofilm removal was identified in continuous ECT as compared with intermittent ECT. These results aimed to highlight the opportunity for biofouling mitigation by ECT for irrigation systems, and reveal the potential anti-biofilm microbial mechanisms of ECT.
Collapse
Affiliation(s)
- Peng Song
- College of Water Resources and Civil Engineering, China Agricultural University, Beijing 100083, China
| | - Yang Xiao
- College of Water Resources and Civil Engineering, China Agricultural University, Beijing 100083, China
| | - Zhiyong Jason Ren
- Department of Civil and Environmental Engineering and Andlinger Center for Energy and the Environment, Princeton University, Princeton, NJ, 08544, United States
| | - John P Brooks
- Genetics and Sustainable Agricultural Research Unit, United States Department of Agriculture, Starkville, MS 39762, USA
| | - Lu Lu
- Department of Civil and Environmental Engineering and Andlinger Center for Energy and the Environment, Princeton University, Princeton, NJ, 08544, United States
| | - Bo Zhou
- College of Water Resources and Civil Engineering, China Agricultural University, Beijing 100083, China
| | - Yunpeng Zhou
- College of Water Resources and Civil Engineering, China Agricultural University, Beijing 100083, China
| | - Stefano Freguia
- Advanced Water Management Centre, University of Queensland, Brisbane, QLD 4072, Australia
| | - Zhidan Liu
- College of Water Resources and Civil Engineering, China Agricultural University, Beijing 100083, China
| | - Ning Zhang
- College of Water Resources and Civil Engineering, China Agricultural University, Beijing 100083, China
| | - Yunkai Li
- College of Water Resources and Civil Engineering, China Agricultural University, Beijing 100083, China.
| |
Collapse
|
36
|
Vatansever C, Turetgen I. Investigation of the effects of various stress factors on biofilms and planktonic bacteria in cooling tower model system. Arch Microbiol 2021; 203:1411-1425. [PMID: 33388788 DOI: 10.1007/s00203-020-02116-2] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/19/2020] [Revised: 09/09/2020] [Accepted: 11/08/2020] [Indexed: 11/27/2022]
Abstract
Biofilm is a microbial population which live in a self-produced extracellular polymeric matrix by attaching to surfaces. Biofilms consist of different different types of organisms such as bacteria, fungi, protozoa, etc. Many biofilms that develop in nature consist of more than one type of organism. Biofilms protect bacteria from adverse conditions such as temperature fluctuation and disinfectants. The aim of this study was to determine the effective elimination strategies for combating biofilm and planktonic bacteria in cooling tower model system using different decontamination / disinfection techniques. In this study, 14 week-old biofilms were treated with temperatures of 4 °C, 65 °C; pH of 3, 11; 2 and 10 mg/l chlorine, 2 and 10 mg/l monochloramine; hypotonic salt (0.01% NaCl) and hypertonic salt (3% NaCl) solution. For enumeration, number of aerobic heterotrophic bacteria was determined by conventional culture method, number of live bacteria was determined by LIVE/DEAD viability kit, CTC-DAPI and Alamar blue staining methods. Temperature of 65 °C, pH of 3, 10 mg/l monochloramine and hypertonic salt solution were the most effective parameters for decontamination of biofilm and planktonic bacteria. Biofilm bacteria in the circulating water system were significantly more resistant than planktonic bacteria against stress factors. When the numbers of epifluorescence microscopy and conventional culture technique were compared, significantly higher number of live bacteria were detected using epifluorescence microscopy. Bacteria enter the viable but non-culturable phase by loosing their culturability under stress conditions. For this reason, the conventional culture method should be supported by different techniques to get more realistic numbers.
Collapse
Affiliation(s)
- Cansu Vatansever
- Faculty of Pharmacy, Department of Pharmaceutical Microbiology, Altinbas University, Istanbul, Turkey.
| | - Irfan Turetgen
- Faculty of Science, Department of Biology, Istanbul University, Istanbul, Turkey
| |
Collapse
|
37
|
Antibiotic Resistance in Recreational Waters: State of the Science. INTERNATIONAL JOURNAL OF ENVIRONMENTAL RESEARCH AND PUBLIC HEALTH 2020; 17:ijerph17218034. [PMID: 33142796 PMCID: PMC7663426 DOI: 10.3390/ijerph17218034] [Citation(s) in RCA: 35] [Impact Index Per Article: 7.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 10/07/2020] [Revised: 10/27/2020] [Accepted: 10/28/2020] [Indexed: 12/14/2022]
Abstract
Ambient recreational waters can act as both recipients and natural reservoirs for antimicrobial resistant (AMR) bacteria and antimicrobial resistant genes (ARGs), where they may persist and replicate. Contact with AMR bacteria and ARGs potentially puts recreators at risk, which can thus decrease their ability to fight infections. A variety of point and nonpoint sources, including contaminated wastewater effluents, runoff from animal feeding operations, and sewer overflow events, can contribute to environmental loading of AMR bacteria and ARGs. The overall goal of this article is to provide the state of the science related to recreational exposure and AMR, which has been an area of increasing interest. Specific objectives of the review include (1) a description of potential sources of antibiotics, AMR bacteria, and ARGs in recreational waters, as documented in the available literature; (2) a discussion of what is known about human recreational exposures to AMR bacteria and ARGs, using findings from health studies and exposure assessments; and (3) identification of knowledge gaps and future research needs. To better understand the dynamics related to AMR and associated recreational water risks, future research should focus on source contribution, fate and transport-across treatment and in the environment; human health risk assessment; and standardized methods.
Collapse
|
38
|
Carlson AL, Daigger GT, Love NG, Hart E. Multi-year diagnosis of unpredictable fouling occurrences in a full-scale membrane bioreactor. WATER SCIENCE AND TECHNOLOGY : A JOURNAL OF THE INTERNATIONAL ASSOCIATION ON WATER POLLUTION RESEARCH 2020; 82:524-536. [PMID: 32960797 DOI: 10.2166/wst.2020.354] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/11/2023]
Abstract
The membrane bioreactor (MBR) at the Traverse City Regional Wastewater Treatment Plant has experienced sudden and unpredictable periods of substantial permeability decline since 2011. Early observations detected irregularly-shaped Gram-positive bacteria that correlated with plant upsets. Use of biomolecular techniques, such as DNA sequencing of laboratory isolates and the mixed liquor microbial community, and fluorescent in situ hybridization, identified the dispersed organisms as members of the genus Staphylococcus. However, Staphylococcus species were consistently present during normal operation and therefore were more likely to be an indicator of the upset, not the cause. The results suggest that these microorganisms are responding to specific influent wastewater constituents. We chemically analysed seven mixed liquor samples from periods of permeability decline in 2017 and 2018, and four samples from a period of normal operation. During upset conditions, the total carbohydrate content exceeded that of normal operation by 40%. Additionally, mixed liquor calcium concentrations were 65% above normal during the upset in 2017. It is hypothesized and supported through multivariate statistical analysis and estimation of specific resistance to filtration values that a calcium-intermediated polymer bridging mechanism with extracellular polymeric substance constituents is a major contributor to fouling and permeability disruptions in the Traverse City MBR.
Collapse
Affiliation(s)
- A L Carlson
- Department of Environmental Engineering, University of Michigan, 1351 Beal Avenue, Ann Arbor, MI 48109, USA E-mail:
| | - G T Daigger
- Department of Environmental Engineering, University of Michigan, 1351 Beal Avenue, Ann Arbor, MI 48109, USA E-mail:
| | - N G Love
- Department of Environmental Engineering, University of Michigan, 1351 Beal Avenue, Ann Arbor, MI 48109, USA E-mail:
| | - E Hart
- Traverse City Regional Wastewater Treatment Plant, 606 Hannah Avenue, Traverse City, MI 49686, USA
| |
Collapse
|
39
|
Zhao L, Liu YW, Li N, Fan XY, Li X. Response of bacterial regrowth, abundant and rare bacteria and potential pathogens to secondary chlorination in secondary water supply system. THE SCIENCE OF THE TOTAL ENVIRONMENT 2020; 719:137499. [PMID: 32120107 DOI: 10.1016/j.scitotenv.2020.137499] [Citation(s) in RCA: 21] [Impact Index Per Article: 4.2] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 01/16/2020] [Revised: 02/18/2020] [Accepted: 02/20/2020] [Indexed: 06/10/2023]
Abstract
This study investigated the effects of secondary chlorination on bacterial regrowth, microbial communities (abundant and rare taxa) and bacterial functions of pipe wall biofilm and bulk water in simulated secondary water supply system (SWSS). Continuous secondary chlorination was more effective than short-term secondary chlorination to control the bacterial regrowth in both biofilm and water samples. Bacterial diversity slightly reduced after continuous secondary chlorination, and 19.27% of the total operational taxonomic units (OTUs) were shared by biofilm and water samples, with Bacillus as the dominant genus. Abundant and rare taxa exhibited different community structures. Proteobacteria and candidate division WPS-1 predominated in abundant and rare phyla were sensitive to chlorine, while Firmicutes, Acidobacteria and Bacteroidetes, exhibited relative strong chlorine resistance. The abundant genera in control sample (e.g., Bosea, Sphingobium and Gemmata) exhibited poor tolerance to chlorine, while Bacillus in biofilm and Defluviimonas in water were the main chlorine-resistant genera. Moreover, the composition of rare genera in each sample was obviously different. Furthermore, a total of 18 potential pathogens were detected with Pseudomonas as the dominant genus, most of which were significantly reduced after disinfection. There were mainly positive interactions among potential pathogenic bacteria, with Enterococcus, Legionella and Vibrio as the hub genera as revealed by network analysis. Similar bacterial functions in both biofilm and water were observed with metabolism as the predominant bacterial function, while, human disease function only accounted for 1.07% of bacterial functions. These results highlighted the importance of continuous secondary chlorination for controlling biosafety of SWSS and identified the dissimilar responses of abundant and rare bacteria to the disinfection, as well as the co-occurrence patterns among potential pathogens, improving our understanding of bacterial communities in SWSS.
Collapse
Affiliation(s)
- Li Zhao
- China Architecture Design and Research Group, Beijing 100044, PR China
| | - Yong-Wang Liu
- China Architecture Design and Research Group, Beijing 100044, PR China; College of Architecture and Civil engineering, Beijing University of Technology, Beijing 100124, PR China.
| | - Na Li
- College of Architecture and Civil engineering, Beijing University of Technology, Beijing 100124, PR China
| | - Xiao-Yan Fan
- College of Architecture and Civil engineering, Beijing University of Technology, Beijing 100124, PR China
| | - Xing Li
- College of Architecture and Civil engineering, Beijing University of Technology, Beijing 100124, PR China
| |
Collapse
|
40
|
Brumfield KD, Hasan NA, Leddy MB, Cotruvo JA, Rashed SM, Colwell RR, Huq A. A comparative analysis of drinking water employing metagenomics. PLoS One 2020; 15:e0231210. [PMID: 32271799 PMCID: PMC7145143 DOI: 10.1371/journal.pone.0231210] [Citation(s) in RCA: 30] [Impact Index Per Article: 6.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/04/2019] [Accepted: 03/18/2020] [Indexed: 12/13/2022] Open
Abstract
The microbiological content of drinking water traditionally is determined by employing culture-dependent methods that are unable to detect all microorganisms, especially those that are not culturable. High-throughput sequencing now makes it possible to determine the microbiome of drinking water. Thus, the natural microbiota of water and water distribution systems can now be determined more accurately and analyzed in significantly greater detail, providing comprehensive understanding of the microbial community of drinking water applicable to public health. In this study, shotgun metagenomic analysis was performed to determine the microbiological content of drinking water and to provide a preliminary assessment of tap, drinking fountain, sparkling natural mineral, and non-mineral bottled water. Predominant bacterial species detected were members of the phyla Actinobacteria and Proteobacteria, notably the genera Alishewanella, Salmonella, and Propionibacterium in non-carbonated non-mineral bottled water, Methyloversatilis and Methylibium in sparkling natural mineral water, and Mycobacterium and Afipia in tap and drinking fountain water. Fecal indicator bacteria, i.e., Escherichia coli or enterococci, were not detected in any samples examined in this study. Bacteriophages and DNA encoding a few virulence-associated factors were detected but determined to be present only at low abundance. Antibiotic resistance markers were detected only at abundance values below our threshold of confidence. DNA of opportunistic plant and animal pathogens was identified in some samples and these included bacteria (Mycobacterium spp.), protozoa (Acanthamoeba mauritaniensis and Acanthamoeba palestinensis), and fungi (Melampsora pinitorqua and Chryosporium queenslandicum). Archaeal DNA (Candidatus Nitrosoarchaeum) was detected only in sparkling natural mineral water. This preliminary study reports the complete microbiome (bacteria, viruses, fungi, and protists) of selected types of drinking water employing whole-genome high-throughput sequencing and bioinformatics. Investigation into activity and function of the organisms detected is in progress.
Collapse
Affiliation(s)
- Kyle D. Brumfield
- Maryland Pathogen Research Institute, University of Maryland, MD, College Park, United States of America
- University of Maryland Institute for Advanced Computer Studies, University of Maryland, College Park, MD, United States of America
| | - Nur A. Hasan
- University of Maryland Institute for Advanced Computer Studies, University of Maryland, College Park, MD, United States of America
- CosmosID Inc., Rockville, MD, United States of America
| | - Menu B. Leddy
- Essential Environmental and Engineering Systems, Huntington Beach, CA, United States of America
| | - Joseph A. Cotruvo
- Joseph Cotruvo and Associates LLC, Washington, DC, United States of America
| | - Shah M. Rashed
- Maryland Pathogen Research Institute, University of Maryland, MD, College Park, United States of America
- CosmosID Inc., Rockville, MD, United States of America
| | - Rita R. Colwell
- Maryland Pathogen Research Institute, University of Maryland, MD, College Park, United States of America
- University of Maryland Institute for Advanced Computer Studies, University of Maryland, College Park, MD, United States of America
- CosmosID Inc., Rockville, MD, United States of America
| | - Anwar Huq
- Maryland Pathogen Research Institute, University of Maryland, MD, College Park, United States of America
| |
Collapse
|
41
|
Han Z, An W, Yang M, Zhang Y. Assessing the impact of source water on tap water bacterial communities in 46 drinking water supply systems in China. WATER RESEARCH 2020; 172:115469. [PMID: 31954932 DOI: 10.1016/j.watres.2020.115469] [Citation(s) in RCA: 65] [Impact Index Per Article: 13.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 09/06/2019] [Revised: 12/31/2019] [Accepted: 01/02/2020] [Indexed: 06/10/2023]
Abstract
Drinking water purification and distribution processes shape the bacterial community in tap water; however, this study calls attention to the impact of source water on tap water bacterial community. Herein, paired source and tap water samples were collected from 46 drinking water supply systems in different watersheds across China, and high-throughput sequencing delineated that bacterial richness and diversity decreased and biogeographical distribution pattern weakened in tap water compared to source water. Despite the great changes of bacteria from source to tap, Bayesian-based SourceTracker analysis still verified that the proportional contributions of source water to shaping the tap water bacterial community ranged from 0% to 92.8% (49.73% ± 30.22% on average). This indelible contribution was further confirmed by the Mantel test (P < 0.001), Procrustes test (P < 0.001) and variance partition analysis, which showed that the source water together with geographical location explained 40.11% of tap water bacterial community variation. To explore the potential reasons that explain the great differences in the impact of source water among different samples, the universal shift pattern of bacterial communities from source to tap was summarized as a classification of dominant bacterial taxa: "sensitive taxa" versus "resistant taxa". The taxa including Planctomycetes, Verrucomicrobia, Acidobacteria, Chloroflexi, and δ-Proteobacteria could act as biomarkers to distinguish samples between source and tap water, and were classified as sensitive taxa. In contrast, α-Proteobacteria, β-Proteobacteria, γ-Proteobacteria, Actinobacteria, Firmicutes, Bacteroidetes, and Cyanobacteria were classified as resistant taxa. The abundance of sensitive taxa was negatively correlated with the SourceTracker proportion, while the abundance of resistant taxa was positively correlated with the SourceTracker proportion (P < 0.01). Thus, variation in source water bacterial community could be responsible for the degree of impact on tap water. Our findings give notice that the impact of source water microbiomes must be taken more seriously, and sufficient source water protection and engineering control strategies should be implemented to prevent the biological consequences of source water on tap water.
Collapse
Affiliation(s)
- Ziming Han
- State Key Laboratory of Environmental Aquatic Chemistry, Research Center for Eco-Environmental Sciences, Chinese Academy of Sciences, Beijing, 100085, China; University of Chinese Academy of Sciences, Beijing, 100049, China.
| | - Wei An
- Key Laboratory of Drinking Water Science and Technology, Research Center for Eco-Environmental Sciences, Chinese Academy of Sciences, Beijing, 100085, China.
| | - Min Yang
- Key Laboratory of Drinking Water Science and Technology, Research Center for Eco-Environmental Sciences, Chinese Academy of Sciences, Beijing, 100085, China; University of Chinese Academy of Sciences, Beijing, 100049, China.
| | - Yu Zhang
- State Key Laboratory of Environmental Aquatic Chemistry, Research Center for Eco-Environmental Sciences, Chinese Academy of Sciences, Beijing, 100085, China; University of Chinese Academy of Sciences, Beijing, 100049, China.
| |
Collapse
|
42
|
Dai Z, Sevillano-Rivera MC, Calus ST, Bautista-de Los Santos QM, Eren AM, van der Wielen PWJJ, Ijaz UZ, Pinto AJ. Disinfection exhibits systematic impacts on the drinking water microbiome. MICROBIOME 2020; 8:42. [PMID: 32197656 PMCID: PMC7085177 DOI: 10.1186/s40168-020-00813-0] [Citation(s) in RCA: 45] [Impact Index Per Article: 9.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 11/22/2019] [Accepted: 02/25/2020] [Indexed: 05/06/2023]
Abstract
Limiting microbial growth during drinking water distribution is achieved either by maintaining a disinfectant residual or through nutrient limitation without using a disinfectant. The impact of these contrasting approaches on the drinking water microbiome is not systematically understood. We use genome-resolved metagenomics to compare the structure, metabolic traits, and population genomes of drinking water microbiome samples from bulk drinking water across multiple full-scale disinfected and non-disinfected drinking water systems. Microbial communities cluster at the structural- and functional potential-level based on the presence/absence of a disinfectant residual. Disinfectant residual alone explained 17 and 6.5% of the variance in structure and functional potential of the drinking water microbiome, respectively, despite including multiple drinking water systems with variable source waters and source water communities and treatment strategies. The drinking water microbiome is structurally and functionally less diverse and variable across disinfected compared to non-disinfected systems. While bacteria were the most abundant domain, archaea and eukaryota were more abundant in non-disinfected and disinfected systems, respectively. Community-level differences in functional potential were driven by enrichment of genes associated with carbon and nitrogen fixation in non-disinfected systems and γ-aminobutyrate metabolism in disinfected systems likely associated with the recycling of amino acids. Genome-level analyses for a subset of phylogenetically-related microorganisms suggests that disinfection selects for microorganisms capable of using fatty acids, presumably from microbial decay products, via the glyoxylate cycle. Overall, we find that disinfection exhibits systematic selective pressures on the drinking water microbiome and may select for microorganisms able to utilize microbial decay products originating from disinfection-inactivated microorganisms. Video abstract.
Collapse
Affiliation(s)
- Zihan Dai
- Infrastructure and Environment Research Division, School of Engineering, University of Glasgow, G12 8LT, Glasgow, UK
| | | | - Szymon T Calus
- Infrastructure and Environment Research Division, School of Engineering, University of Glasgow, G12 8LT, Glasgow, UK
| | | | - A Murat Eren
- Department of Medicine, University of Chicago, Chicago, IL, USA
- Josephine Bay Paul Center, Marine Biological Laboratory, Woods Hole, MA, USA
| | - Paul W J J van der Wielen
- KWR Watercycle Research Institute, Nieuwegein, Netherlands
- Laboratory of Microbiology, Wageningen University, Wageningen, Netherlands
| | - Umer Z Ijaz
- Infrastructure and Environment Research Division, School of Engineering, University of Glasgow, G12 8LT, Glasgow, UK
| | - Ameet J Pinto
- Department of Civil and Environmental Engineering, Northeastern University, Boston, MA, USA.
| |
Collapse
|
43
|
Cui Q, Liu H, Yang HW, Lu Y, Chen Z, Hu HY. Bacterial removal performance and community changes during advanced treatment process: A case study at a full-scale water reclamation plant. THE SCIENCE OF THE TOTAL ENVIRONMENT 2020; 705:135811. [PMID: 31837874 DOI: 10.1016/j.scitotenv.2019.135811] [Citation(s) in RCA: 26] [Impact Index Per Article: 5.2] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 09/11/2019] [Revised: 11/25/2019] [Accepted: 11/26/2019] [Indexed: 06/10/2023]
Abstract
Advanced treatment is of great significance to water reclamation and reuse, which can improve water quality, control microbial risks and guarantee the safety of water reuse. This study evaluates the microbial quantity and bacterial community dynamics during advanced wastewater treatment and reuse processes (i.e. denitrification biofilter (DNBF), ultrafiltration (UF), ozonation, ultraviolet (UV) disinfection) at a large-scale water reclamation plant. It is found that different treatment processes had significant influence on the cultivability of total bacteria and the log reduction values of fecal coliform at DNBF, UF, ozonation and UV are calculated as 0.38, 2.46, 0.38 and 1.63 respectively. Moreover, the bacterial diversity in the treatment process showed apparent spatial differences, among which the effluent from ozonation process had the lowest bacterial diversity. Sequencing analysis indicated the existence of pathogenic bacterium such as Arcobacter, Bacteroides and Pseudomonas in the secondary effluent. Notably, Pseudomonas remained the most dominant species (relative abundance 41.9% in UV effluent) in reclaimed water after advanced treatment processes, which calls for high attention to sustainable water reuse. In order to inhibit bacterial regrowth in the storage tank, chlorine disinfection is recommended to improve the continuous disinfection capability of the system.
Collapse
Affiliation(s)
- Qi Cui
- Environmental Simulation and Pollution Control State Key Joint Laboratory, State Environmental Protection Key Laboratory of Microorganism Application and Risk Control (SMARC), School of Environment, Tsinghua University, Beijing 100084, PR China
| | - Hai Liu
- Environmental Simulation and Pollution Control State Key Joint Laboratory, State Environmental Protection Key Laboratory of Microorganism Application and Risk Control (SMARC), School of Environment, Tsinghua University, Beijing 100084, PR China
| | - Hong-Wei Yang
- Research Institute for Environmental Innovation (Suzhou), Tsinghua University, Suzhou 215163, PR China
| | - Yun Lu
- Environmental Simulation and Pollution Control State Key Joint Laboratory, State Environmental Protection Key Laboratory of Microorganism Application and Risk Control (SMARC), School of Environment, Tsinghua University, Beijing 100084, PR China
| | - Zhuo Chen
- Environmental Simulation and Pollution Control State Key Joint Laboratory, State Environmental Protection Key Laboratory of Microorganism Application and Risk Control (SMARC), School of Environment, Tsinghua University, Beijing 100084, PR China.
| | - Hong-Ying Hu
- Environmental Simulation and Pollution Control State Key Joint Laboratory, State Environmental Protection Key Laboratory of Microorganism Application and Risk Control (SMARC), School of Environment, Tsinghua University, Beijing 100084, PR China; Shenzhen Environmental Science and New Energy Technology Engineering Laboratory, Tsinghua-Berkeley Shenzhen Institute, Shenzhen 518055, PR China.
| |
Collapse
|
44
|
Chloramine Disinfection-Induced Nitrification Activities and Their Potential Public Health Risk Indications within Deposits of a Drinking Water Supply System. INTERNATIONAL JOURNAL OF ENVIRONMENTAL RESEARCH AND PUBLIC HEALTH 2020; 17:ijerph17030772. [PMID: 31991878 PMCID: PMC7037617 DOI: 10.3390/ijerph17030772] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 12/25/2019] [Revised: 01/20/2020] [Accepted: 01/22/2020] [Indexed: 11/17/2022]
Abstract
Microsensors were applied to study the diffusion reaction and activity of a nitrogen species of deposit sediment from a drinking water supply system. Microprofiles of dissolved oxygen (DO), NH4+-N, NO3--N, and NO2-N in the sediment indicated that the DO concentration decreased from the highest at the sediment surface to zero at the bottom of the sediment. Similarly, with the increase of depth, NH4+-N initially increased rapidly and then decreased slowly, while the concentration of NO3--N reached a maximum at around 6000 μm and then decreased to about 0.1 mg·L-1 near the bottom of the sediment. Almost no change was observed for NO2--N. The decrease of NH4+-N and DO corresponded well with the increase of NO3--N. Furthermore, based on a consumption and production rate analysis, DO has always been consumed; the NH4+-N consumption rate increased rapidly within 0-1000 μm, reaching about 14 mg·L-1·S-1·10-9. A small amount of NH4+-N was produced in 2000-6000 μm, which could be attributed to denitrification activity. There was no change deeper than 6000 μm, while NO3--N was produced at a depth between 0 and 6000 μm and was consumed in the deeper zone. At the depth of 9000 μm, the NO3--N consumption reached a maximum of 5 mg·L-1·S-1·10-9. The consumption of DO and NH4+-N, which corresponded with the production of NO3--N in a specific microscale range within the sediment, demonstrated nitrification and denitrification activities. In addition, the time required for the diffusion of only DO, NH4+-N, NO3--N, and NO2--N was estimated as 14 days; however, in the practical, even after 60 days of operation, there was still a continuous reaction, which provided further evidence towards microbial activities within the sediment.
Collapse
|
45
|
Gu Y, Xiao F, Luo L, Zhou X, Zhou X, Li J, Li Z. Bacterial Disinfection by CuFe 2O 4 Nanoparticles Enhanced by NH 2OH: A Mechanistic Study. NANOMATERIALS (BASEL, SWITZERLAND) 2019; 10:E18. [PMID: 31861627 PMCID: PMC7022556 DOI: 10.3390/nano10010018] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 11/18/2019] [Revised: 12/14/2019] [Accepted: 12/16/2019] [Indexed: 12/16/2022]
Abstract
Many disinfection technologies have emerged recently in water treatment industry, which are designed to inactivate water pathogens with extraordinary efficiency and minimum side effects and costs. Current disinfection processes, including chlorination, ozonation, UV irradiation, and so on, have their inherent drawbacks, and have been proven ineffective under certain scenarios. Bacterial inactivation by noble metals has been traditionally used, and copper is an ideal candidate as a bactericidal agent owing to its high abundance and low cost. Building on previous findings, we explored the bactericidal efficiency of Cu(I) and attempted to develop it into a novel water disinfection platform. Nanosized copper ferrite was synthesized, and it was reduced by hydroxylamine to form surface bound Cu(I) species. Our results showed that the generated Cu(I) on copper ferrite surface could inactivate E. coli at a much higher efficiency than Cu(II) species. Elevated reactive oxygen species' content inside the cell primarily accounted for the strong bactericidal role of Cu(I), which may eventually lead to enhanced oxidative stress towards cell membrane, DNA, and functional proteins. The developed platform in this study is promising to be integrated into current water treatment industry.
Collapse
Affiliation(s)
- Yu Gu
- School of Mechanical and Eletrical Engineering, Zhoukou Normal University, Zhoukou 466000, China; (L.L.); (X.Z.); (X.Z.); (J.L.)
| | - Furen Xiao
- College of Materials Science and Engineering and State Key Laboratory of Metastable Materials Science and Technology, Yanshan University, Qinhuangdao 066004, China;
| | - Liumin Luo
- School of Mechanical and Eletrical Engineering, Zhoukou Normal University, Zhoukou 466000, China; (L.L.); (X.Z.); (X.Z.); (J.L.)
| | - Xiaoyu Zhou
- School of Mechanical and Eletrical Engineering, Zhoukou Normal University, Zhoukou 466000, China; (L.L.); (X.Z.); (X.Z.); (J.L.)
| | - Xiaodong Zhou
- School of Mechanical and Eletrical Engineering, Zhoukou Normal University, Zhoukou 466000, China; (L.L.); (X.Z.); (X.Z.); (J.L.)
| | - Jin Li
- School of Mechanical and Eletrical Engineering, Zhoukou Normal University, Zhoukou 466000, China; (L.L.); (X.Z.); (X.Z.); (J.L.)
| | - Zhi Li
- California State University San Bernardino, 5500 University Pkwy, San Bernardino, CA 92407, USA;
| |
Collapse
|
46
|
Mapping Dynamics of Bacterial Communities in a Full-Scale Drinking Water Distribution System Using Flow Cytometry. WATER 2019. [DOI: 10.3390/w11102137] [Citation(s) in RCA: 12] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/16/2022]
Abstract
Microbial monitoring of drinking water is required to guarantee high quality water and to mitigate health hazards. Flow cytometry (FCM) is a fast and robust method that determines bacterial concentrations in liquids. In this study, FCM was applied to monitor the dynamics of the bacterial communities over one year in a full-scale drinking water distribution system (DWDS), following implementation of ultrafiltration (UF) combined with coagulation at the drinking water treatment plant (DWTP). Correlations between the environmental conditions in the DWDS and microbial regrowth were observed, including increases in total cell counts with increasing retention time (correlation coefficient R = 0.89) and increasing water temperature (up to 5.24-fold increase in cell counts during summer). Temporal and spatial biofilm dynamics affecting the water within the DWDS were also observed, such as changes in the percentage of high nucleic acid bacteria with increasing retention time (correlation coefficient R = −0.79). FCM baselines were defined for specific areas in the DWDS to support future management strategies in this DWDS, including a gradual reduction of chloramine.
Collapse
|
47
|
Microbial Dynamics of Biosand Filters and Contributions of the Microbial Food Web to Effective Treatment of Wastewater-Impacted Water Sources. Appl Environ Microbiol 2019; 85:AEM.01142-19. [PMID: 31227556 DOI: 10.1128/aem.01142-19] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/20/2019] [Accepted: 06/18/2019] [Indexed: 12/30/2022] Open
Abstract
Biosand filtration systems are widely used for drinking water treatment, from household-level, intermittently operated filters to large-scale continuous municipal systems. While it is well-established that microbial activity within the filter is essential for the removal of potential pathogens and other contaminants, the microbial ecology of these systems and how microbial succession relates to their performance remain poorly resolved. We determined how different source waters influence the composition, temporal dynamics, and performance of microbial communities in intermittently operated biosand filters. We operated lab-scale biosand filters, adding daily inputs from two contrasting water sources with differing nutrient concentrations and found that total coliform removal increased and became less variable after 4 weeks, regardless of water source. Total effluent biomass was also lower than total influent biomass for both water sources. Bacterial community composition, assessed via cultivation-independent DNA sequencing, varied by water source, sample type (influent, effluent, or sand), and time. Despite these differences, we identified specific taxa that were consistently removed, including common aquatic and wastewater bacteria. In contrast, taxa consistently more abundant in the sand and effluent included predatory, intracellular, and symbiotic bacteria.IMPORTANCE Although microbial activities are known to contribute to the effectiveness of biosand filtration for drinking water treatment, we have a limited understanding of what microbial groups are most effectively removed, colonize the sand, or make it through the filter. This study tracked the microbial communities in the influent, sand, and effluent of lab-scale, intermittently operated biosand filters over 8 weeks. These results represent the most detailed and time-resolved investigation of the microbial communities in biosand filters typical of those implemented at the household level in many developing countries. We show the importance of the microbial food web in biosand filtration, and we identified taxa that are preferentially removed from wastewater-impacted water sources. We found consistent patterns in filter effectiveness from source waters with differing nutrient loads and, likewise, identified specific bacterial taxa that were consistently more abundant in effluent waters, taxa that are important targets for further study and posttreatment.
Collapse
|
48
|
Hu D, Lin W, Zeng J, Wu P, Zhang M, Guo L, Ye C, Wan K, Yu X. Profiling the microbial contamination in aviation fuel from an airport. BIOFOULING 2019; 35:856-869. [PMID: 31603000 DOI: 10.1080/08927014.2019.1671977] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 03/24/2019] [Revised: 09/14/2019] [Accepted: 09/16/2019] [Indexed: 06/10/2023]
Abstract
Microbial contamination during fuel storage can cause fuel system fouling and corrosion. Characterizing microbial contamination is critical for preventing and solving these problems. In this study, culture-based combing with the culture-independent methods, were used to profile the microbial contamination in aviation fuel. High-throughput sequencing (HTS) modified by propidium monoazide (PMA) revealed a higher diversity of contaminating microorganisms in samples than the culture method. Proteobacteria (47%), Actinobacteria (21%) and Ascomycota (>99%, fungi) were the most abundant phyla, and the neglected archaea was also detected. Additionally, qPCR-based methods revealed all samples contained a heavy level of microbial contamination, which was more accurate than its culturable counterparts, and fungal contamination was still a problem in aviation fuel. The application of a PCR-based method gives deeper insight into microbial contamination in aviation fuel than the conventional culture method, thus using it for regular detection and accurate description of fuel contamination is strongly recommended in the case of explosive microbial growth.
Collapse
Affiliation(s)
- Dong Hu
- Key Lab of Urban Environment and Health, Institute of Urban Environment, Chinese Academy of Sciences, Xiamen, People's Republic of China
- University of Chinese Academy of Sciences, Beijing, People's Republic of China
| | - Wenfang Lin
- Key Lab of Urban Environment and Health, Institute of Urban Environment, Chinese Academy of Sciences, Xiamen, People's Republic of China
| | - Jie Zeng
- Key Lab of Urban Environment and Health, Institute of Urban Environment, Chinese Academy of Sciences, Xiamen, People's Republic of China
- University of Chinese Academy of Sciences, Beijing, People's Republic of China
| | - Peng Wu
- Key Lab of Urban Environment and Health, Institute of Urban Environment, Chinese Academy of Sciences, Xiamen, People's Republic of China
| | - Menglu Zhang
- Key Lab of Urban Environment and Health, Institute of Urban Environment, Chinese Academy of Sciences, Xiamen, People's Republic of China
- University of Chinese Academy of Sciences, Beijing, People's Republic of China
| | - Lizheng Guo
- Key Lab of Urban Environment and Health, Institute of Urban Environment, Chinese Academy of Sciences, Xiamen, People's Republic of China
- University of Chinese Academy of Sciences, Beijing, People's Republic of China
| | - Chengsong Ye
- Key Lab of Urban Environment and Health, Institute of Urban Environment, Chinese Academy of Sciences, Xiamen, People's Republic of China
| | - Kun Wan
- Key Lab of Urban Environment and Health, Institute of Urban Environment, Chinese Academy of Sciences, Xiamen, People's Republic of China
- University of Chinese Academy of Sciences, Beijing, People's Republic of China
| | - Xin Yu
- Key Lab of Urban Environment and Health, Institute of Urban Environment, Chinese Academy of Sciences, Xiamen, People's Republic of China
| |
Collapse
|
49
|
Liu H, Wahman DG, Pressman JG. Evaluation of Monochloramine and Free Chlorine Penetration in a Drinking Water Storage Tank Sediment Using Microelectrodes. ENVIRONMENTAL SCIENCE & TECHNOLOGY 2019; 53:9352-9360. [PMID: 31287953 PMCID: PMC6759989 DOI: 10.1021/acs.est.9b01189] [Citation(s) in RCA: 16] [Impact Index Per Article: 2.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/31/2023]
Abstract
Sediment accumulation in water storage tanks may protect microorganisms from disinfectant exposure, causing the degradation of water quality. However, microbial activity and disinfectant penetration within water storage sediment remain largely uncharacterized. This study evaluated the penetration of monochloramine and free chlorine into a 2 cm (20000 μm) deep drinking water storage tank sediment using microelectrodes. The sediment was successively exposed to monochloramine for 4 months, free chlorine for 2 months, and monochloramine for 2 months. Temporal monochloramine, free chlorine, dissolved oxygen (DO), pH, ammonium, nitrite, and nitrate profiles were acquired using microelectrodes. The results showed that complete monochloramine or free chlorine penetration was not observed. Likewise, DO never fully penetrated the sediment, progressing inward with time to a maximum depth of 10000 μm and indicating microbial activity persisted over the entire 8 months. Decreasing ammonium and increasing nitrate concentrations, with minimal nitrite accumulation, further demonstrated microbial activity and indicated complete sediment nitrification. There were measurable levels of ammonium, nitrite, and nitrate during free chlorine application, and nitrification activity gradually resumed upon a switch back to monochloramine. These findings suggest that the periodic removal of sediment from drinking water storage facilities is desirable to remove potentially protected environments for microorganisms.
Collapse
Affiliation(s)
- Hong Liu
- Oak Ridge Institute for Science and Education (ORISE) Post-Doctoral Fellow at U.S. Environmental Protection Agency, Cincinnati, OH 45268, United States
| | - David G. Wahman
- National Risk Management Research Laboratory, U.S. Environmental Protection Agency, Cincinnati, Ohio 45268, United States
| | - Jonathan G. Pressman
- National Risk Management Research Laboratory, U.S. Environmental Protection Agency, Cincinnati, Ohio 45268, United States
| |
Collapse
|
50
|
Waak MB, LaPara TM, Hallé C, Hozalski RM. Nontuberculous Mycobacteria in Two Drinking Water Distribution Systems and the Role of Residual Disinfection. ENVIRONMENTAL SCIENCE & TECHNOLOGY 2019; 53:8563-8573. [PMID: 31287948 DOI: 10.1021/acs.est.9b01945] [Citation(s) in RCA: 30] [Impact Index Per Article: 5.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/09/2023]
Abstract
Nontuberculous mycobacteria (NTM) are frequently found in chloraminated drinking water distribution systems (DWDSs) due to their chloramine tolerance. NTM were investigated in the water-main biofilms and drinking water of a chloraminated DWDS in the United States (initial chloramine residual = 3.8 ± 0.1 mg L-1) and a DWDS in Norway with minimal residual disinfectant (0.08 ± 0.01 mg L-1). Total mycobacteria and Mycobacterium avium complex (MAC) were quantified by qPCR targeting, respectively, atpE genes and the internal transcribed spacer region. Mycobacteria concentrations in drinking water did not differ between the two systems (P = 0.09; up to 6 × 104 copies L-1) but were higher in the biofilms from the chloraminated DWDS (P = 5 × 10-9; up to 5 × 106 copies cm-2). MAC were not detected in either system. Sequencing of mycobacterial hsp65 genes indicated that the chloraminated DWDS lacked diversity and consisted almost exclusively of M. gordonae. In contrast, there were various novel mycobacteria in the no-residual DWDS. Finally, Mycobacterium- and Methylobacterium-like 16S rRNA genes were often detected simultaneously, though without correlation as previously observed. We conclude that, though residual chloramine may increase mycobacterial biomass in a DWDS, it may also decrease mycobacterial diversity.
Collapse
Affiliation(s)
- Michael B Waak
- Department of Civil, Environmental, and Geo-Engineering , University of Minnesota , 500 Pillsbury Dr. SE , Minneapolis , Minnesota 55455 , United States
- Department of Civil and Environmental Engineering , Norwegian University of Science and Technology , S.P. Andersens veg 5 , 7491 Trondheim , Norway
| | - Timothy M LaPara
- Department of Civil, Environmental, and Geo-Engineering , University of Minnesota , 500 Pillsbury Dr. SE , Minneapolis , Minnesota 55455 , United States
- BioTechnology Institute , University of Minnesota , 1479 Gortner Ave. , St. Paul , Minnesota 55108 , United States
| | - Cynthia Hallé
- Department of Civil and Environmental Engineering , Norwegian University of Science and Technology , S.P. Andersens veg 5 , 7491 Trondheim , Norway
| | - Raymond M Hozalski
- Department of Civil, Environmental, and Geo-Engineering , University of Minnesota , 500 Pillsbury Dr. SE , Minneapolis , Minnesota 55455 , United States
- BioTechnology Institute , University of Minnesota , 1479 Gortner Ave. , St. Paul , Minnesota 55108 , United States
| |
Collapse
|