1
|
Schütte F, Friebe S, Böttcher D, Borger MA, Uhlemann M, Mayr SG. Prediction of tissue rupture from percolation of local strain heterogeneities for diagnostics. COMMUNICATIONS MEDICINE 2025; 5:197. [PMID: 40413338 PMCID: PMC12103514 DOI: 10.1038/s43856-025-00897-5] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/19/2024] [Accepted: 05/07/2025] [Indexed: 05/27/2025] Open
Abstract
BACKGROUND A plethora of medical conditions, ranging from torn ligaments to aneurysmic blood vessels, are caused by failure of mechanically stressed biological tissues until rupture. Clearly prediction of the potential loci of tissue failure prior to rupture is highly desirable for prophylactic measures, preferentially in sufficiently early stages of the disease. METHODS Mechanical heterogeneities are identified from local mechanical strains obtained from image sequences recorded during uniaxial tensile testing of reconstituted collagen (both, in experiments and finite element model (FEM) calculations) and horse aorta explants, respectively, as well as of the pulsating aorta using magnetic resonance imaging (MRI). RESULTS Within this work we present a comprehensive study on the biomechanical concept that percolated local mechanical strain heterogeneities can serve as valid indicators to predict the loci of tissue rupture already from straining behavior within the elastic regime. While we first experimentally validate the predictive capabilities of our strain percolation analysis for reconstituted rat tail collagen fibers and horse aorta explants, we unveil the structural origins of mechanical heterogeneities on the network level using FEM calculations based on digitized confocal laser scanning microscopy (CLSM) measurements. To demonstrate the diagnostic capabilities, we successfully predict potential occurrence and location of an aortic aneurysm in a patient with documented Marfan syndrome from MRI video sequences recorded of the pulsating aorta six years prior to surgery. CONCLUSIONS Detection of local mechanical heterogeneities and their percolation behavior bears predictive capabilities for tissue failure before it actually has occurred and thus promises large potential for diagnostics and therapy.
Collapse
Affiliation(s)
- Friedrich Schütte
- Leibniz Institute of Surface Engineering (IOM), Leipzig, Germany
- Division of Surface Physics, Department of Physics and Earth System Sciences, University of Leipzig, Leipzig, Germany
| | - Sabrina Friebe
- Leibniz Institute of Surface Engineering (IOM), Leipzig, Germany
- Division of Surface Physics, Department of Physics and Earth System Sciences, University of Leipzig, Leipzig, Germany
| | - Denny Böttcher
- Faculty of Veterinary Medicine, University of Leipzig, Leipzig, Germany
| | | | - Madlen Uhlemann
- Department of Cardiac Surgery, Leipzig Heart Center, Leipzig, Germany
| | - Stefan G Mayr
- Leibniz Institute of Surface Engineering (IOM), Leipzig, Germany.
- Division of Surface Physics, Department of Physics and Earth System Sciences, University of Leipzig, Leipzig, Germany.
| |
Collapse
|
2
|
Lee S, Van Dyke M, Kim M. Recombinant keratin: Comprehensive review of synthesis, hierarchical assembly, properties, and applications. Acta Biomater 2025; 198:1-21. [PMID: 40180006 DOI: 10.1016/j.actbio.2025.03.056] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/29/2024] [Revised: 03/20/2025] [Accepted: 03/31/2025] [Indexed: 04/05/2025]
Abstract
Keratin has gained attention for its remarkable mechanical properties, thermal stability, and beneficial biological properties, such as promoting hemostasis and wound healing. Traditionally, keratin has been extracted from natural sources, including human hair, wool, and feathers, and processed into biomaterials, including films, hydrogels, and nanoparticles, primarily for biomedical applications. However, extraction methods often result in heterogeneous keratin mixtures with residual impurities and structural degradation due to harsh purification conditions, complicating efforts to understand how specific keratins and their hierarchical assemblies contribute to desired material properties. Recombinant keratin technology addresses these challenges by enabling the synthesis of individual keratin types with high purity and batch-to-batch consistency. These advancements facilitate studies on how individual and combined keratins at various assembly stagesfrom molecular components and heterodimers to intermediate filaments (IFs) and IF networksimpact material properties. Moreover, this technology allows for precise genetic modifications, potentially leading to engineered keratin variants with tailored characteristics for targeted applications. Despite these advantages, translating recombinant keratin into practical applications requires overcoming key manufacturing challenges, such as optimizing large-scale production and improving purification efficiency. This review presents the current state of recombinant keratin research by highlighting its advancements and exploring current biomaterial applications. While its applications remain limited compared to extracted keratin at this early stage, its potential offers future opportunities for extending its use in advanced material design and beyond biomedical fields. STATEMENT OF SIGNIFICANCE: Keratin and keratinized structures provide essential protection to tissues against mechanical stress and environmental damage, serving as foundational elements across diverse biological systems. This review discusses advancements in recombinant keratin technology, enabling high-purity, reproducible synthesis with controlled composition modifications that effectively overcome the limitations of traditional extraction methods. The innovations deepen our understanding of hierarchical assembly in keratin structures across various length scales, along with their reinforcing mechanisms and mechanical and biofunctional properties. These insights lay the groundwork for biomaterials tailored to regenerative medicine, wound healing, and other biomedical applications. By focusing on the unique capabilities of recombinant keratin, this review offers a valuable resource for future advancements in high-performance biomaterials across biomedical and biotechnological fields.
Collapse
Affiliation(s)
- Suyoung Lee
- Department of Materials Science and Engineering, University of Arizona, Tucson, AZ 85721, USA
| | - Mark Van Dyke
- Department of Biomedical Engineering, University of Arizona, Tucson, AZ 85721, USA; BIO5 Institute, University of Arizona, Tucson, AZ 85721, USA
| | - Minkyu Kim
- Department of Materials Science and Engineering, University of Arizona, Tucson, AZ 85721, USA; Department of Biomedical Engineering, University of Arizona, Tucson, AZ 85721, USA; BIO5 Institute, University of Arizona, Tucson, AZ 85721, USA.
| |
Collapse
|
3
|
Giannetti G, Matsumura F, Caporaletti F, Micha D, Koenderink GH, Ilie IM, Bonn M, Woutersen S, Giubertoni G. Water and Collagen: A Mystery Yet to Unfold. Biomacromolecules 2025; 26:2784-2799. [PMID: 40208305 PMCID: PMC12076498 DOI: 10.1021/acs.biomac.4c01735] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/11/2024] [Revised: 03/18/2025] [Accepted: 03/19/2025] [Indexed: 04/11/2025]
Abstract
Collagen is the most abundant protein in the human body and plays an essential role in determining the mechanical properties of the tissues. Both as a monomeric protein and in fibrous assemblies, collagen interacts with its surrounding molecules, in particular with water. Interestingly, while it is well established that the interaction with water strongly influences the molecular and mechanical properties of collagen and its assemblies, the underlying mechanisms remain largely unknown. Here, we review the research conducted over the past 30 years on the interplay between water and collagen and its relevance for tissue properties. We discuss the water-collagen interaction on relevant time- and length scales, ranging from the vital role of water in stabilizing the characteristic triple helix structure to the negative impact of dehydration on the mechanical properties of tissues. A better understanding of the water-collagen interaction will help to unravel the effect of mutations and defective collagen production in collagen-related diseases and to pinpoint the key design features required to synthesize collagen-based biomimetic tissues with tailored mechanical properties.
Collapse
Affiliation(s)
- Guido Giannetti
- University
of Vienna, Faculty of Physics, Boltzmanngasse 5, 1090 Vienna, Austria
| | | | - Federico Caporaletti
- Laboratory
of Polymer and Soft Matter Dynamics, Experimental Soft Matter and
Thermal Physics (EST), Université
libre de Bruxelles (ULB), Brussels 1050, Belgium
| | - Dimitra Micha
- Amsterdam
University Medical Centers (UMC), Vrije
Universiteit Amsterdam, 1007 MB Amsterdam, The Netherlands
| | - Gijsje H. Koenderink
- Department
of Bionanoscience, Kavli Institute of Nanoscience Delft, Delft University of Technology, 2629 HC Delft, The Netherlands
| | - Ioana Mariuca Ilie
- Van ’t
Hoff Institute for Molecular Sciences, University
of Amsterdam, Science Park 904, 1098 XH Amsterdam, The Netherlands
| | - Mischa Bonn
- Max
Planck Institute for Polymer Research, 55128 Mainz, Germany
- Van
der Waals-Zeeman Institute, Institute of Physics, University of Amsterdam, 1098 XH Amsterdam, The Netherlands
| | - Sander Woutersen
- Van ’t
Hoff Institute for Molecular Sciences, University
of Amsterdam, Science Park 904, 1098 XH Amsterdam, The Netherlands
| | - Giulia Giubertoni
- Van ’t
Hoff Institute for Molecular Sciences, University
of Amsterdam, Science Park 904, 1098 XH Amsterdam, The Netherlands
| |
Collapse
|
4
|
Dong L, Zhang M, Wang D. Modeling and design of 3D printed hyperelastic lattice metamaterials with bionic S-shaped stress-strain behaviors. MATERIALS HORIZONS 2025. [PMID: 40289754 DOI: 10.1039/d4mh01582g] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 04/30/2025]
Abstract
Lattice metamaterials made of stiff polymers, ceramics, and metals have been extensively designed to reproduce the mechanical behaviors of biological tissues, holding promising applications in biomedical devices and tissue engineering. However, lattice metamaterials composed of soft materials have been far less explored due to challenges posed by material nonlinearity and large deformations. Here, hyperelastic lattice metamaterials with curved microstructures are fabricated by 3D printing elastomers and are developed to mimic bionic S-shaped stress-strain behaviors. We propose a design framework for 3D printed hyperelastic lattice metamaterials that integrates digital geometry generation, hierarchical mechanics modeling, and validation by finite element (FE) simulations and experiments. The microstructures are modeled through deriving a Timoshenko-type beam theory governed by hyperelastic strain energy potentials. The model is then combined with the deformation and equilibrium analysis considering non-rigid connections between microstructures to predict the mechanical responses of hyperelastic lattice metamaterials. Using the developed design framework, programmable S-shaped stress-strain behaviors and high fracture strains (over 800%) are achieved. We demonstrate S-shaped stress-strain curves that match skeletal and cardiac muscles and highly stretchable lattice sensors for remote controls. This study provides design methods and theoretical guidelines for hyperelastic lattice metamaterials, holding promise for robotic sensors with bionic performance and functionality.
Collapse
Affiliation(s)
- Le Dong
- State Key Laboratory of Mechanical System and Vibration, School of Mechanical Engineering, Shanghai Jiao Tong University, Shanghai 200240, China.
- Shanghai Key Laboratory of Intelligent Robotics, Meta Robotics Institute, Shanghai Jiao Tong University, Shanghai 200240, China
| | - Mengjie Zhang
- State Key Laboratory of Mechanical System and Vibration, School of Mechanical Engineering, Shanghai Jiao Tong University, Shanghai 200240, China.
- Shanghai Key Laboratory of Intelligent Robotics, Meta Robotics Institute, Shanghai Jiao Tong University, Shanghai 200240, China
| | - Dong Wang
- State Key Laboratory of Mechanical System and Vibration, School of Mechanical Engineering, Shanghai Jiao Tong University, Shanghai 200240, China.
- Shanghai Key Laboratory of Intelligent Robotics, Meta Robotics Institute, Shanghai Jiao Tong University, Shanghai 200240, China
| |
Collapse
|
5
|
Qiu PF, Qiang L, Kong W, Wang FZ, Wang HQ, Hou KX, Liu Y, Li CH, Zheng P. A soft, ultra-tough and multifunctional artificial muscle for volumetric muscle loss treatment. Natl Sci Rev 2025; 12:nwae422. [PMID: 39830399 PMCID: PMC11737398 DOI: 10.1093/nsr/nwae422] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/10/2024] [Revised: 10/17/2024] [Accepted: 11/20/2024] [Indexed: 01/22/2025] Open
Abstract
The escalating prevalence of skeletal muscle disorders highlights the critical need for innovative treatments for severe injuries such as volumetric muscle loss. Traditional treatments, such as autologous transplants, are constrained by limited availability and current scaffolds often fail to meet complex clinical needs. This study introduces a new approach to volumetric muscle loss treatment by using a shape-memory polymer (SMP) based on block copolymers of perfluoropolyether and polycaprolactone diol. This SMP mimics the biomechanical properties of natural muscle, exhibiting a low elastic modulus (2-6 MPa), high tensile strength (72.67 ± 3.19 MPa), exceptional toughness (742.02 ± 23.98 MJ m-3) and superior biocompatibility, thereby enhancing skeletal muscle tissue integration and regeneration within 4 weeks. Moreover, the polymer's shape-memory behavior and ability to lift >5000 times its weight showcase significant potential in both severe muscle disorder treatment and prosthetic applications, surpassing existing scaffold technologies. This advancement marks a pivotal step in the development of artificial muscles for clinical use.
Collapse
Affiliation(s)
- Peng-Fei Qiu
- State Key Laboratory of Coordination Chemistry, School of Chemistry and Chemical Engineering, Collaborative Innovation Center of Advanced Microstructures, Nanjing University, Nanjing 210023, China
| | - Lei Qiang
- Department of Orthopaedic Surgery, Children's Hospital of Nanjing Medical University, Nanjing 210004, China
| | - Weiqing Kong
- Department of Orthopedic Surgery, Xuzhou Central Hospital, Xuzhou Clinical School of Xuzhou Medical University, Xuzhou 221009, China
| | - Fang-Zhou Wang
- State Key Laboratory of Coordination Chemistry, School of Chemistry and Chemical Engineering, Collaborative Innovation Center of Advanced Microstructures, Nanjing University, Nanjing 210023, China
| | - Hong-Qin Wang
- State Key Laboratory of Coordination Chemistry, School of Chemistry and Chemical Engineering, Collaborative Innovation Center of Advanced Microstructures, Nanjing University, Nanjing 210023, China
| | - Ke-Xin Hou
- State Key Laboratory of Coordination Chemistry, School of Chemistry and Chemical Engineering, Collaborative Innovation Center of Advanced Microstructures, Nanjing University, Nanjing 210023, China
| | - Yihao Liu
- Shanghai Key Laboratory of Orthopedic Implant, Department of Orthopedic Surgery, Shanghai Ninth People's Hospital, Shanghai Jiao Tong University School of Medicine, Shanghai 200011, China
| | - Cheng-Hui Li
- State Key Laboratory of Coordination Chemistry, School of Chemistry and Chemical Engineering, Collaborative Innovation Center of Advanced Microstructures, Nanjing University, Nanjing 210023, China
| | - Pengfei Zheng
- Department of Orthopaedic Surgery, Children's Hospital of Nanjing Medical University, Nanjing 210004, China
| |
Collapse
|
6
|
Kolozsvary T, Kohl P, Li T, Gillespie D, Li Y, McDonald BR. The Precise Synthesis of Ultradense Bottlebrush Polymers Unearths Unique Trends in Lyotropic Ordering. J Am Chem Soc 2025; 147:889-897. [PMID: 39718550 DOI: 10.1021/jacs.4c13759] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/25/2024]
Abstract
Biomacromolecular networks with multiscale fibrillar structures are characterized by exceptional mechanical properties, making them attractive architectures for synthetic materials. However, there is a dearth of synthetic polymeric building blocks capable of forming similarly structured networks. Bottlebrush polymers (BBPs) are anisotropic graft polymers with the potential to mimic and replace biomacromolecules such as tropocollagen for the fabrication of synthetic fibrillar networks; however, a longstanding limitation of BBPs has been the lack of rigidity necessary to access the lyotropic ordering that underpins the formation of collagenous networks. While the correlation between BBP rigidity and grafting density is well established, synthetic approaches to rigidify BBPs by increased grafting density are underdeveloped. To address this gap in synthetic capability, we report the synthesis of novel macroinitiators that provide well-defined BBPs with an unprecedentedly high grafting density. A suite of light scattering techniques are used to correlate macromolecular rigidity with grafting architecture and density and demonstrate for the first time that poly(norbornene) BBPs exhibit long-range lyotropic ordering as a result of their rodlike character. Specifically, the newly reported ultradensely grafted structures, preparable on multigram scale, form hexagonal arrays while conventional BBPs do not, despite showing long-range spatial correlations. These results implicate the central role of density and entanglement in the solution phase assembly of BBPs and provide new fundamental insight that is broadly relevant to the fabrication and performance of BBP-derived materials, spanning biomedical research to photonic materials and thermal management technologies. Furthermore, these newly reported liquid crystalline BBPs provide a structural template to explore the untapped potential of the bottom-up assembly of semiflexible networks and are ultimately intended to provide a modular route to hierarchically structured biomimetic materials.
Collapse
Affiliation(s)
- Timea Kolozsvary
- Department of Chemistry at Brown University, 324 Brook Street, Providence, Rhode Island 02912, United States
| | - Phillip Kohl
- Materials Research Laboratory at UC Santa Barbara, Santa Barbara, California 93106, United States
| | - Tianyu Li
- TOSOH Bioscience Inc., 3604 Horizon Drive #100, King of Prussia, Pennsylvania 19406, United States
| | - David Gillespie
- TOSOH Bioscience Inc., 3604 Horizon Drive #100, King of Prussia, Pennsylvania 19406, United States
| | - Youli Li
- Materials Research Laboratory at UC Santa Barbara, Santa Barbara, California 93106, United States
| | - Benjamin R McDonald
- Department of Chemistry at Brown University, 324 Brook Street, Providence, Rhode Island 02912, United States
| |
Collapse
|
7
|
Alloisio M, Siika A, Freiholtz D, Franco-Cereceda A, Roy J, Björck HM, Gasser TC. Fracture properties of porcine versus human thoracic aortas from tricuspid/bicuspid aortic valve patients via symmetry-constraint Compact Tension testing. Sci Rep 2025; 15:667. [PMID: 39753641 PMCID: PMC11699116 DOI: 10.1038/s41598-024-83233-6] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/17/2024] [Accepted: 12/12/2024] [Indexed: 01/06/2025] Open
Abstract
Aneurysm rupture is a life-threatening event, yet its underlying mechanisms remain largely unclear. This study investigated the fracture properties of the thoracic aneurysmatic aorta (TAA) using the symmetry-constraint Compact Tension (symconCT) test and compared results to native and enzymatic-treated porcine aortas' tests. With age, the aortic stiffness increased, and tissues ruptured at lower fracture energy [Formula: see text]. Patients with bicuspid aortic valves were more sensitive to age, had stronger aortas and required more [Formula: see text] than tricuspid valves individuals (peak load: axial loading 4.42 ± 1.56 N vs 2.51 ± 1.60 N; circumferential loading 5.76 ± 2.43 N vs 4.82 ± 1.49 N. Fracture energy: axial loading 1.92 ± 0.60 kJ m-2 vs 0.74 ± 0.50 kJ m-2; circumferential loading 2.12 ± 2.39 kJ m-2 vs 1.47 ± 0.91 kJ m-2). Collagen content partly explained the variability in [Formula: see text], especially in bicuspid cases. Besides the primary crack, TAAs and enzymatic-treated porcine aortas displayed diffuse and shear-dominated dissection and tearing. As human tissue tests resembled enzymatic-treated porcine aortas, microstructural degeneration, including elastin loss and collagen degeneration, seems to be the main cause of TAA wall weakening. Additionally, a tortuous crack developing during the symconCT test reflected intact fracture toughening mechanisms and might characterize a healthier aorta.
Collapse
Affiliation(s)
- Marta Alloisio
- Department of Engineering Mechanics, KTH Royal Institute of Technology, Stockholm, Sweden
| | - Antti Siika
- Department of Molecular Medicine and Surgery, Karolinska Institutet, Stockholm, Sweden
| | - David Freiholtz
- Section of Cardiothoracic Surgery, Department of Molecular Medicine and Surgery, Karolinska Institutet, Stockholm, Sweden
- Division of Cardiology, Center for Molecular Medicine, Department of Medicine, Karolinska University Hospital, Karolinska Institutet, Solna, Stockholm, Sweden
| | - Anders Franco-Cereceda
- Section of Cardiothoracic Surgery, Department of Molecular Medicine and Surgery, Karolinska Institutet, Stockholm, Sweden
| | - Joy Roy
- Department of Molecular Medicine and Surgery, Karolinska Institutet, Stockholm, Sweden
- Department of Vascular Surgery, Karolinska University Hospital, Karolinska Institutet, Stockholm, Sweden
| | - Hanna M Björck
- Division of Cardiology, Center for Molecular Medicine, Department of Medicine, Karolinska University Hospital, Karolinska Institutet, Solna, Stockholm, Sweden
| | - T Christian Gasser
- Department of Engineering Mechanics, KTH Royal Institute of Technology, Stockholm, Sweden.
| |
Collapse
|
8
|
Yu H, Jafari M, Mujahid A, Garcia CF, Shah J, Sinha R, Huang Y, Shakiba D, Hong Y, Cheraghali D, Pryce JRS, Sandler JA, Elson EL, Sacks JM, Genin GM, Alisafaei F. Expansion limits of meshed split-thickness skin grafts. Acta Biomater 2025; 191:325-335. [PMID: 39581335 DOI: 10.1016/j.actbio.2024.11.038] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/27/2024] [Revised: 11/08/2024] [Accepted: 11/21/2024] [Indexed: 11/26/2024]
Abstract
Split-thickness skin grafts are widely used to treat chronic wounds. Procedure design requires surgeons to predict how much a patch of the patient's own skin expands when it is meshed with rows of slits and stretched over a larger wound area. Accurate prediction of graft expansion remains a challenge, with current models overestimating the actual expansion, leading to suboptimal outcomes. Inspired by the principles of mechanical metamaterials, we developed a model that distinguishes between the kinematic rearrangement of structural elements and their stretching, providing a more accurate prediction of skin graft expansion. Our model was validated against extensive data from skin graft surgeries, demonstrating vastly superior predictive capability compared to existing methods. This metamaterial-inspired approach enables informed decision-making for potentially improving healing outcomes. STATEMENT OF SIGNIFICANCE: Accurately predicting the expansion of meshed skin grafts is crucial for minimizing patient trauma and optimizing healing outcomes in reconstructive surgery. However, current quantitative models, which treat grafts as tessellated trusses of rigid bars, fail to accurately estimate graft expansion. We have uncovered the mechanisms underlying skin graft expansion and developed a straightforward method based on these findings. This method, designed for practical use by surgeons, provides accurate predictions of graft expansion, as validated against extensive data from skin graft surgeries.
Collapse
Affiliation(s)
- Haomin Yu
- NSF Science and Technology Center for Engineering Mechanobiology, USA; Department of Mechanical Engineering and Materials Science, Washington University in St. Louis, USA
| | - Mohammad Jafari
- NSF Science and Technology Center for Engineering Mechanobiology, USA; Department of Mechanical Engineering, New Jersey Institute of Technology, USA
| | - Aliza Mujahid
- NSF Science and Technology Center for Engineering Mechanobiology, USA; Department of Mechanical Engineering, New Jersey Institute of Technology, USA
| | - Chelsea F Garcia
- Department of Mechanical Engineering, New Jersey Institute of Technology, USA
| | - Jaisheel Shah
- Department of Mechanical Engineering, New Jersey Institute of Technology, USA
| | - Riya Sinha
- Department of Mechanical Engineering, New Jersey Institute of Technology, USA
| | - Yuxuan Huang
- NSF Science and Technology Center for Engineering Mechanobiology, USA; Department of Biomedical Engineering, Washington University in St. Louis, USA
| | - Delaram Shakiba
- NSF Science and Technology Center for Engineering Mechanobiology, USA; Department of Pathology, Johns Hopkins University, USA
| | - Yuan Hong
- NSF Science and Technology Center for Engineering Mechanobiology, USA; Department of Mechanical Engineering and Materials Science, Washington University in St. Louis, USA
| | - Danial Cheraghali
- NSF Science and Technology Center for Engineering Mechanobiology, USA; Department of Mechanical Engineering, New Jersey Institute of Technology, USA
| | - John R S Pryce
- Department of Mechanical Engineering, New Jersey Institute of Technology, USA
| | - Jacob A Sandler
- NSF Science and Technology Center for Engineering Mechanobiology, USA; Department of Mechanical Engineering and Materials Science, Washington University in St. Louis, USA
| | - Elliot L Elson
- NSF Science and Technology Center for Engineering Mechanobiology, USA; Department of Mechanical Engineering and Materials Science, Washington University in St. Louis, USA; Department of Biochemistry and Molecular Biophysics, Washington University in St. Louis School of Medicine, USA
| | - Justin M Sacks
- Division of Plastic and Reconstructive Surgery, Washington University in St. Louis School of Medicine, USA
| | - Guy M Genin
- NSF Science and Technology Center for Engineering Mechanobiology, USA; Department of Mechanical Engineering and Materials Science, Washington University in St. Louis, USA; Department of Biomedical Engineering, Washington University in St. Louis, USA.
| | - Farid Alisafaei
- NSF Science and Technology Center for Engineering Mechanobiology, USA; Department of Mechanical Engineering, New Jersey Institute of Technology, USA.
| |
Collapse
|
9
|
Liu Z, Ling SD, Liang K, Chen Y, Niu Y, Sun L, Li J, Du Y. Viscoelasticity of ECM and cells-origin, measurement and correlation. MECHANOBIOLOGY IN MEDICINE 2024; 2:100082. [PMID: 40395221 PMCID: PMC12082326 DOI: 10.1016/j.mbm.2024.100082] [Citation(s) in RCA: 2] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 03/09/2024] [Revised: 07/14/2024] [Accepted: 07/15/2024] [Indexed: 05/22/2025]
Abstract
The extracellular matrix (ECM) and cells are crucial components of natural tissue microenvironments, and they both demonstrate dynamic mechanical properties, particularly viscoelastic behaviors, when exposed to external stress or strain over time. The capacity to modify the mechanical properties of cells and ECM is crucial for gaining insight into the development, physiology, and pathophysiology of living organisms. As an illustration, researchers have developed hydrogels with diverse compositions to mimic the properties of the native ECM and use them as substrates for cell culture. The behavior of cultured cells can be regulated by modifying the viscoelasticity of hydrogels. Moreover, there is widespread interest across disciplines in accurately measuring the mechanical properties of cells and the surrounding ECM, as well as exploring the interactive relationship between these components. Nevertheless, the lack of standardized experimental methods, conditions, and other variables has hindered systematic comparisons and summaries of research findings on ECM and cell viscoelasticity. In this review, we delve into the origins of ECM and cell viscoelasticity, examine recently developed methods for measuring ECM and cell viscoelasticity, and summarize the potential interactions between cell and ECM viscoelasticity. Recent research has shown that both ECM and cell viscoelasticity experience alterations during in vivo pathogenesis, indicating the potential use of tailored viscoelastic ECM and cells in regenerative medicine.
Collapse
Affiliation(s)
- Zhiqiang Liu
- Department of Biomedical Engineering, School of Medicine, Tsinghua-Peking Center for Life Sciences, Tsinghua University, Beijing 100084, China
| | - Si Da Ling
- Department of Biomedical Engineering, School of Medicine, Tsinghua-Peking Center for Life Sciences, Tsinghua University, Beijing 100084, China
| | - Kaini Liang
- Department of Biomedical Engineering, School of Medicine, Tsinghua-Peking Center for Life Sciences, Tsinghua University, Beijing 100084, China
| | - Yihan Chen
- Department of Biomedical Engineering, School of Medicine, Tsinghua-Peking Center for Life Sciences, Tsinghua University, Beijing 100084, China
| | - Yudi Niu
- Department of Biomedical Engineering, School of Medicine, Tsinghua-Peking Center for Life Sciences, Tsinghua University, Beijing 100084, China
| | - Lei Sun
- Department of Biomedical Engineering, School of Medicine, Tsinghua-Peking Center for Life Sciences, Tsinghua University, Beijing 100084, China
| | - Junyang Li
- Department of Biomedical Engineering, School of Medicine, Tsinghua-Peking Center for Life Sciences, Tsinghua University, Beijing 100084, China
| | - Yanan Du
- Department of Biomedical Engineering, School of Medicine, Tsinghua-Peking Center for Life Sciences, Tsinghua University, Beijing 100084, China
| |
Collapse
|
10
|
Vieceli AS, Silveira PCL, Zaccaron RP, Fonseca MDCR, Aguiar-Junior AS, Neves LMSD, Kuriki HU, Barbosa RI, Marcolino AM. Influence of photobiomodulation and radiofrequency on the healing of pressure lesions in mice. Lasers Med Sci 2024; 39:280. [PMID: 39542938 DOI: 10.1007/s10103-024-04226-5] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/28/2024] [Accepted: 10/28/2024] [Indexed: 11/17/2024]
Abstract
The objective of this study was to ascertain the impact of photobiomodulation and radiofrequency on the healing of pressure injuries in mice. A total of 70 animals were randomly assigned to seven experimental groups. A pressure injury was induced in the dorsal region of the mice by the application of two magnets. The photobiomodulation treatment was administered at a dosage of 3.6 J per session. In the radiofrequency group, the treatment time was four minutes and the power was 22 watts. The analyses included the lesion area, infrared thermography, and the collection of material for cytokine, histological, and histochemical analyses following euthanasia. In the macroscopic analyses, the 660 nm photobiomodulation group demonstrated superior outcomes in comparison to the control group. With regard to the microscopic analyses, the greatest difference between the groups was observed when TNF-α was evaluated in the photobiomodulation group. It can be observed that the groups irradiated by electrophysical means (i.e., a combination of radiofrequency with PBM 830 nm-660 nm) exhibited a positive influence on the repair process, with the greatest impact observed in the group irradiated by a combination of radiofrequency and 660 nm photobiomodulation.
Collapse
Affiliation(s)
- Aline Santo Vieceli
- Laboratory of Assessment and Rehabilitation of the Locomotor Apparatus (LARAL), Department of Health Sciences, Universidade Federal de Santa Catarina, Rua Pedro João Pereira, 150, room 111, Mato Alto, Araranguá, Santa Catarin, CEP 88905-120, Brazil
- Postgraduate Program in Rehabilitation Sciences, Federal University of Santa Catarina (LARAL/UFSC), Rua Pedro João Pereira, 150, Araranguá, Santa Catarina, CEP 88905-120, Brazil
| | - Paulo Cesar Lock Silveira
- Laboratory of Experimental Physiopathology, Program of Postgraduate in Science of Health, Universidade do Extremo Sul Catarinense, Criciúma, Santa Catarina, 88806-000, Brazil
| | - Rubya Pereira Zaccaron
- Laboratory of Experimental Physiopathology, Program of Postgraduate in Science of Health, Universidade do Extremo Sul Catarinense, Criciúma, Santa Catarina, 88806-000, Brazil
| | - Marisa de Cássia Registro Fonseca
- Postgraduate Program in Rehabilitation and Functional Performance, Ribeirão Preto Medical School of the University of São Paulo (USP), Av. dos Bandeirantes, 3900, Ribeirão Preto, São Paulo, 14049-900, Brazil
| | - Aderbal Silva Aguiar-Junior
- Federal University of Santa Catarina, Laboratório Biologia do Exercício Físico (LaBioEx), Rua Pedro João Pereira, 150, Araranguá, Santa Catarina, CEP 88905-120, Brazil
| | - Lais Mara Siqueira das Neves
- Postgraduate Program in Rehabilitation and Functional Performance, Ribeirão Preto Medical School of the University of São Paulo (USP), Av. dos Bandeirantes, 3900, Ribeirão Preto, São Paulo, 14049-900, Brazil
| | - Heloyse Uliam Kuriki
- Laboratory of Assessment and Rehabilitation of the Locomotor Apparatus (LARAL), Department of Health Sciences, Universidade Federal de Santa Catarina, Rua Pedro João Pereira, 150, room 111, Mato Alto, Araranguá, Santa Catarin, CEP 88905-120, Brazil
- Postgraduate Program in Rehabilitation Sciences, Federal University of Santa Catarina (LARAL/UFSC), Rua Pedro João Pereira, 150, Araranguá, Santa Catarina, CEP 88905-120, Brazil
| | - Rafael Inacio Barbosa
- Laboratory of Assessment and Rehabilitation of the Locomotor Apparatus (LARAL), Department of Health Sciences, Universidade Federal de Santa Catarina, Rua Pedro João Pereira, 150, room 111, Mato Alto, Araranguá, Santa Catarin, CEP 88905-120, Brazil
- Postgraduate Program in Rehabilitation Sciences, Federal University of Santa Catarina (LARAL/UFSC), Rua Pedro João Pereira, 150, Araranguá, Santa Catarina, CEP 88905-120, Brazil
| | - Alexandre Marcio Marcolino
- Laboratory of Assessment and Rehabilitation of the Locomotor Apparatus (LARAL), Department of Health Sciences, Universidade Federal de Santa Catarina, Rua Pedro João Pereira, 150, room 111, Mato Alto, Araranguá, Santa Catarin, CEP 88905-120, Brazil.
- Postgraduate Program in Rehabilitation Sciences, Federal University of Santa Catarina (LARAL/UFSC), Rua Pedro João Pereira, 150, Araranguá, Santa Catarina, CEP 88905-120, Brazil.
| |
Collapse
|
11
|
Liu X, Zhang L, Li H, Yang J, Zhang L. The Inhibition of Interfacial Ice Formation and Stress Accumulation with Zwitterionic Betaine and Trehalose for High-Efficiency Skin Cryopreservation. RESEARCH (WASHINGTON, D.C.) 2024; 7:0520. [PMID: 39545039 PMCID: PMC11561590 DOI: 10.34133/research.0520] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 05/26/2024] [Revised: 10/09/2024] [Accepted: 10/12/2024] [Indexed: 11/17/2024]
Abstract
Cryopreservation is a promising technique for the long-term storage of skin. However, the formation of ice crystals during cryopreservation unavoidably damages skin structure and functionality. Currently, the lack of thorough and systematic investigation into the internal mechanisms of skin cryoinjury obstructs the advancement of cryopreservation technology. In this study, we identified 3 primary contributors to skin cryoinjury: interfacial ice nucleation, stress accumulation, and thermal stress escalation. We emphasized the paramount role of interfacial ice nucleation in provoking ice growth within the skin during the cooling process. This progress subsequently leads to stress accumulation within the skin. During the rewarming process, the brittleness of skin, previously subjected to freezing, experienced a marked increase in thermal stress due to ice recrystallization. Based on these insights, we developed a novel zwitterionic betaine-based solution formulation designed for cryopreservation skin. This cryoprotective agent formulation exhibited superior capability in lowering ice nucleation temperatures and inhibiting ice formation at interfaces, while also facilitating the growth of smooth and rounded ice crystals compared to sharp-edged and cornered crystals formed in aqueous solutions. As a result, we successfully achieved prolonged cryopreservation of the skin for at least 6 months, while preserving 98.7% of structural integrity and 94.7% of Young's modulus. This work provides valuable insights into the mechanisms of ice crystal damage during organ cryopreservation and profoundly impacts the field of organ transplantation and regenerative medicine.
Collapse
Affiliation(s)
- Xinmeng Liu
- Department of Biochemical Engineering, Frontier Science Center for Synthetic Biology and Key Laboratory of Systems Bioengineering (MOE), School of Chemical Engineering and Technology,
Tianjin University, Tianjin 300350, China
| | - Liming Zhang
- Department of Biochemical Engineering, Frontier Science Center for Synthetic Biology and Key Laboratory of Systems Bioengineering (MOE), School of Chemical Engineering and Technology,
Tianjin University, Tianjin 300350, China
| | - Haoyue Li
- Department of Biochemical Engineering, Frontier Science Center for Synthetic Biology and Key Laboratory of Systems Bioengineering (MOE), School of Chemical Engineering and Technology,
Tianjin University, Tianjin 300350, China
| | - Jing Yang
- Department of Biochemical Engineering, Frontier Science Center for Synthetic Biology and Key Laboratory of Systems Bioengineering (MOE), School of Chemical Engineering and Technology,
Tianjin University, Tianjin 300350, China
| | - Lei Zhang
- Department of Biochemical Engineering, Frontier Science Center for Synthetic Biology and Key Laboratory of Systems Bioengineering (MOE), School of Chemical Engineering and Technology,
Tianjin University, Tianjin 300350, China
- Haihe Laboratory of Sustainable Chemical Transformations, Tianjin 300192, China
| |
Collapse
|
12
|
Chu C, Sun W, Chen S, Jia Y, Ni Y, Wang S, Han Y, Zuo H, Chen H, You Z, Zhu M. Squid-Inspired Anti-Salt Skin-Like Elastomers With Superhigh Damage Resistance for Aquatic Soft Robots. ADVANCED MATERIALS (DEERFIELD BEACH, FLA.) 2024; 36:e2406480. [PMID: 39267419 DOI: 10.1002/adma.202406480] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 05/06/2024] [Revised: 08/30/2024] [Indexed: 09/17/2024]
Abstract
Cephalopod skins evolve multiple functions in response to environmental adaptation, encompassing nonlinear mechanoreponse, damage tolerance property, and resistance to seawater. Despite tremendous progress in skin-mimicking materials, the integration of these desirable properties into a single material system remains an ongoing challenge. Here, drawing inspiration from the structure of reflectin proteins in cephalopod skins, a long-term anti-salt elastomer with skin-like nonlinear mechanical properties and extraordinary damage resistance properties is presented. Cation-π interaction is incorporated to induce the geometrically confined nanophases of hydrogen bond domains, resulting in elastomers with exceptional true tensile strength (456.5 ± 68.9 MPa) and unprecedently high fracture energy (103.7 ± 45.7 kJ m-2). Furthermore, the cation-π interaction effectively protects the hydrogen bond domains from corrosion by high-concentration saline solution. The utilization of the resultant skin-like elastomer has been demonstrated by aquatic soft robotics capable of grasping sharp objects. The combined advantages render the present elastomer highly promising for salt enviroment applications, particularly in addressing the challenges posed by sweat, in vivo, and harsh oceanic environments.
Collapse
Affiliation(s)
- Chengzhen Chu
- State Key Laboratory for Modification of Chemical Fibers and Polymer Materials, Institute of Functional Materials, College of Materials Science and Engineering, Research Base of Textile Materials for Flexible Electronics and Biomedical Applications (China Textile Engineering Society), Shanghai Engineering Research Center of Nano-Biomaterials and Regenerative Medicine, Donghua University, Shanghai, 201620, P. R. China
| | - Wei Sun
- State Key Laboratory for Modification of Chemical Fibers and Polymer Materials, Institute of Functional Materials, College of Materials Science and Engineering, Research Base of Textile Materials for Flexible Electronics and Biomedical Applications (China Textile Engineering Society), Shanghai Engineering Research Center of Nano-Biomaterials and Regenerative Medicine, Donghua University, Shanghai, 201620, P. R. China
| | - Shuo Chen
- College of Biological Science and Medical Engineering, Donghua University, Shanghai, 201620, P. R. China
| | - Yujie Jia
- State Key Laboratory for Modification of Chemical Fibers and Polymer Materials, Institute of Functional Materials, College of Materials Science and Engineering, Research Base of Textile Materials for Flexible Electronics and Biomedical Applications (China Textile Engineering Society), Shanghai Engineering Research Center of Nano-Biomaterials and Regenerative Medicine, Donghua University, Shanghai, 201620, P. R. China
| | - Yufeng Ni
- State Key Laboratory for Modification of Chemical Fibers and Polymer Materials, Institute of Functional Materials, College of Materials Science and Engineering, Research Base of Textile Materials for Flexible Electronics and Biomedical Applications (China Textile Engineering Society), Shanghai Engineering Research Center of Nano-Biomaterials and Regenerative Medicine, Donghua University, Shanghai, 201620, P. R. China
| | - Shaofan Wang
- State Key Laboratory for Modification of Chemical Fibers and Polymer Materials, Institute of Functional Materials, College of Materials Science and Engineering, Research Base of Textile Materials for Flexible Electronics and Biomedical Applications (China Textile Engineering Society), Shanghai Engineering Research Center of Nano-Biomaterials and Regenerative Medicine, Donghua University, Shanghai, 201620, P. R. China
| | - Yufei Han
- State Key Laboratory for Modification of Chemical Fibers and Polymer Materials, Institute of Functional Materials, College of Materials Science and Engineering, Research Base of Textile Materials for Flexible Electronics and Biomedical Applications (China Textile Engineering Society), Shanghai Engineering Research Center of Nano-Biomaterials and Regenerative Medicine, Donghua University, Shanghai, 201620, P. R. China
| | - Han Zuo
- State Key Laboratory for Modification of Chemical Fibers and Polymer Materials, Institute of Functional Materials, College of Materials Science and Engineering, Research Base of Textile Materials for Flexible Electronics and Biomedical Applications (China Textile Engineering Society), Shanghai Engineering Research Center of Nano-Biomaterials and Regenerative Medicine, Donghua University, Shanghai, 201620, P. R. China
| | - Huifang Chen
- State Key Laboratory for Modification of Chemical Fibers and Polymer Materials, Institute of Functional Materials, College of Materials Science and Engineering, Research Base of Textile Materials for Flexible Electronics and Biomedical Applications (China Textile Engineering Society), Shanghai Engineering Research Center of Nano-Biomaterials and Regenerative Medicine, Donghua University, Shanghai, 201620, P. R. China
| | - Zhengwei You
- State Key Laboratory for Modification of Chemical Fibers and Polymer Materials, Institute of Functional Materials, College of Materials Science and Engineering, Research Base of Textile Materials for Flexible Electronics and Biomedical Applications (China Textile Engineering Society), Shanghai Engineering Research Center of Nano-Biomaterials and Regenerative Medicine, Donghua University, Shanghai, 201620, P. R. China
| | - Meifang Zhu
- State Key Laboratory for Modification of Chemical Fibers and Polymer Materials, Institute of Functional Materials, College of Materials Science and Engineering, Research Base of Textile Materials for Flexible Electronics and Biomedical Applications (China Textile Engineering Society), Shanghai Engineering Research Center of Nano-Biomaterials and Regenerative Medicine, Donghua University, Shanghai, 201620, P. R. China
| |
Collapse
|
13
|
Jiang X, Cheng Y, Shi L, Sun J, Wang R. A Soft, Fatigue-free, and Self-healable Ionic Elastomer via the Synergy of Skin-like Assembly and Bouligand Structure. Angew Chem Int Ed Engl 2024; 63:e202411418. [PMID: 38984508 DOI: 10.1002/anie.202411418] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/18/2024] [Accepted: 07/09/2024] [Indexed: 07/11/2024]
Abstract
Soft ionic elastomers that are self-healable, fatigue-free, and environment-tolerant are ideal structural and sensing materials for artificial prosthetics, soft electronics, and robotics to survive unpredictable service conditions. However, most synthetic strategies failed to unite rapid healing, fatigue resistance, and environmental robustness, limited by their singular compositional/structural designs. Here, we present a soft, tough, fatigue-resistant, and self-healable ionic elastomer (STFSI elastomer), which fuses skin-like binary assembly and Bouligand helicoidal structure into a composite of thermoplastic polyurethane (TPU) fibers and a supramolecular ionic biopolymer. The interlocked binary assembly enables skin-like softness, high stretchability, and strain-adaptive stiffening through a matrix-to-scaffold stress transfer. The Bouligand structure contributes to superhigh fracture toughness (101.6 kJ m-2) and fatigue resistance (4937 J m-2) via mechanical toughening by interlayer slipping and twisted crack propagation path. Besides, the STFSI elastomer is self-healable through a "bridging" method and environment-tolerant (-20 °C, strong acid/alkali, saltwater). To demonstrate the versatile structural and sensing applications, we showcase a safety cushion with efficient damping and suppressed rebounding, and a robotic sensor with excellent fatigue crack tolerance and instant sensation recovery upon cutting-off damage. Our presented synthetic strategy is generalizable to other fiber-reinforced tough polymers for applications involving demanding mechanical/environmental conditions.
Collapse
Affiliation(s)
- Xinyuan Jiang
- State Key Laboratory of High Performance Ceramics and Superfine Microstructure, Shanghai Institute of Ceramics, Chinese Academy of Sciences, 1295 Ding Xi Road, Shanghai, 200050, China
- School of Chemistry and Materials Science, Hangzhou Institute of Advanced Study, University of Chinese Academy of Sciences, Hangzhou, 310024, China
- Center of Materials Science and Optoelectronics Engineering, University of Chinese Academy of Sciences, 1 Sub-lane Xiangshan, Beijing, 100049, China
| | - Yin Cheng
- State Key Laboratory of High Performance Ceramics and Superfine Microstructure, Shanghai Institute of Ceramics, Chinese Academy of Sciences, 1295 Ding Xi Road, Shanghai, 200050, China
| | - Liangjing Shi
- State Key Laboratory of High Performance Ceramics and Superfine Microstructure, Shanghai Institute of Ceramics, Chinese Academy of Sciences, 1295 Ding Xi Road, Shanghai, 200050, China
| | - Jing Sun
- State Key Laboratory of High Performance Ceramics and Superfine Microstructure, Shanghai Institute of Ceramics, Chinese Academy of Sciences, 1295 Ding Xi Road, Shanghai, 200050, China
| | - Ranran Wang
- State Key Laboratory of High Performance Ceramics and Superfine Microstructure, Shanghai Institute of Ceramics, Chinese Academy of Sciences, 1295 Ding Xi Road, Shanghai, 200050, China
- School of Chemistry and Materials Science, Hangzhou Institute of Advanced Study, University of Chinese Academy of Sciences, Hangzhou, 310024, China
| |
Collapse
|
14
|
Shi G, Wang J, Dong Y, Hu S, Zheng L, Ren L. Effect of Surface Morphology and Internal Structure on the Tribological Behaviors of Snake Scales from Dinodon rufozonatum. Biomimetics (Basel) 2024; 9:617. [PMID: 39451823 PMCID: PMC11506616 DOI: 10.3390/biomimetics9100617] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/26/2024] [Revised: 09/30/2024] [Accepted: 10/10/2024] [Indexed: 10/26/2024] Open
Abstract
Snakes can move freely on land, in lakes, and in other environments. During movement, the scales are in long-term contact with the external environment, providing protection to the body. In this study, we evaluated the mechanical properties and scratching performance of the ventral and dorsal scales from Dinodon rufozonatum, a generalist species that moves on both land and in streams under wet and dry conditions. The results showed that the elastic modulus and hardness of the dry scales were greater than those of the wet scales. The average scale friction coefficient under wet conditions (0.1588) was 9.3% greater than that under dry conditions (0.1453). The scales exhibit brittle damage in dry environments, while in wet environments, ductile damage is observed. This adaptation mechanism allows the scales to protect the body by dissipating energy and reducing stress concentration, ensuring efficient locomotion and durability in both terrestrial and aquatic environments. Understanding how this biomaterial adapts to environmental changes can inspire the development of bionic materials.
Collapse
Affiliation(s)
- Ge Shi
- Key Laboratory of Bionic Engineering (Ministry of Education), Jilin University, Changchun 130025, China; (G.S.); (J.W.); (S.H.); (L.R.)
- Weihai Institute for Bionics, Jilin University, Weihai 264402, China;
| | - Jinhao Wang
- Key Laboratory of Bionic Engineering (Ministry of Education), Jilin University, Changchun 130025, China; (G.S.); (J.W.); (S.H.); (L.R.)
- Weihai Institute for Bionics, Jilin University, Weihai 264402, China;
| | - Yuehua Dong
- Weihai Institute for Bionics, Jilin University, Weihai 264402, China;
| | - Song Hu
- Key Laboratory of Bionic Engineering (Ministry of Education), Jilin University, Changchun 130025, China; (G.S.); (J.W.); (S.H.); (L.R.)
- Weihai Institute for Bionics, Jilin University, Weihai 264402, China;
| | - Long Zheng
- Key Laboratory of Bionic Engineering (Ministry of Education), Jilin University, Changchun 130025, China; (G.S.); (J.W.); (S.H.); (L.R.)
- Weihai Institute for Bionics, Jilin University, Weihai 264402, China;
| | - Luquan Ren
- Key Laboratory of Bionic Engineering (Ministry of Education), Jilin University, Changchun 130025, China; (G.S.); (J.W.); (S.H.); (L.R.)
- Weihai Institute for Bionics, Jilin University, Weihai 264402, China;
| |
Collapse
|
15
|
Aubrecht FJ, Orme K, Saul A, Cai H, Ranathunge TA, Silberstein MN, McDonald BR. Ion-Specific Interactions Engender Dynamic and Tailorable Properties in Biomimetic Cationic Polyelectrolytes. Angew Chem Int Ed Engl 2024; 63:e202408673. [PMID: 38981860 DOI: 10.1002/anie.202408673] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/07/2024] [Revised: 06/27/2024] [Accepted: 07/08/2024] [Indexed: 07/11/2024]
Abstract
Biomaterials such as spider silk and mussel byssi are fabricated by the dynamic manipulation of intra- and intermolecular biopolymer interactions. Organisms modulate solution parameters, such as pH and ion co-solute concentration, to effect these processes. These biofabrication schemes provide a conceptual framework to develop new dynamic and responsive abiotic soft material systems. Towards these ends, the chemical diversity of readily available ionic compounds offers a broad palette to manipulate the physicochemical properties of polyelectrolytes via ion-specific interactions. In this study, we show for the first time that the ion-specific interactions of biomimetic polyelectrolytes engenders a variety of phase separation behaviors, creating dynamic thermal- and ion-responsive soft matter that exhibits a spectrum of physical properties, spanning viscous fluids to viscoelastic and viscoplastic solids. These ion-dependent characteristics are further rendered general by the merger of lysine and phenylalanine into a single, amphiphilic vinyl monomer. The unprecedented breadth, precision, and dynamicity in the reported ion-dependent phase behaviors thus introduce a broad array of opportunities for the future development of responsive soft matter; properties that are poised to drive developments in critical areas such as chemical sensing, soft robotics, and additive manufacturing.
Collapse
Affiliation(s)
- Filip J Aubrecht
- Department of Chemistry, Brown University, 324 Brook Street, Providence, RI-02912, USA
| | - Kennalee Orme
- Department of Chemistry, Brown University, 324 Brook Street, Providence, RI-02912, USA
| | - Aiden Saul
- Department of Chemistry, Brown University, 324 Brook Street, Providence, RI-02912, USA
| | - Hongyi Cai
- Materials Science and Engineering, Cornell University, Ithaca, New York, 14853, USA
| | - Tharindu A Ranathunge
- Department of Chemistry, Brown University, 324 Brook Street, Providence, RI-02912, USA
| | - Meredith N Silberstein
- Sibley School of Mechanical and Aerospace Engineering, Cornell University, Ithaca, New York, 14853, USA
| | - Benjamin R McDonald
- Department of Chemistry, Brown University, 324 Brook Street, Providence, RI-02912, USA
| |
Collapse
|
16
|
Fujikawa T, Yamada Y. In vivo video microscopy of the rupturing process of thin blood vessels to clarify the mechanism of bruising caused by blunt impact: an animal study. Biomed Eng Online 2024; 23:94. [PMID: 39261896 PMCID: PMC11389484 DOI: 10.1186/s12938-024-01284-2] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/17/2024] [Accepted: 08/27/2024] [Indexed: 09/13/2024] Open
Abstract
BACKGROUND The thresholds of mechanical inputs for bruising caused by blunt impact are important in the fields of machine safety and forensics. However, reliable data on these thresholds remain inadequate owing to a lack of in vivo experiments, which are crucial for investigating the occurrence of bruising. Since experiments involving live human participants are limited owing to ethical concerns, finite-element method (FEM) simulations of the bruising mechanism should be used to compensate for the lack of experimental data by estimating the thresholds under various conditions, which requires clarifying the mechanism of formation of actual bruises. Therefore, this study aimed to visualize the mechanism underlying the formation of bruises caused by blunt impact to enable FEM simulations to estimate the thresholds of mechanical inputs for bruising. METHODS In vivo microscopy of a transparent glass catfish subjected to blunt contact with an indenter was performed. The fish were anesthetized by immersing them in buffered MS-222 (75-100 mg/L) and then fixed on a subject tray. The indenter, made of transparent acrylic and having a rectangular contact area with dimensions of 1.0 mm × 1.5 mm, was loaded onto the lateral side of the caudal region of the fish. Blood vessels and surrounding tissues were examined through the transparent indenter using a microscope equipped with a video camera. The contact force was measured using a force-sensing table. RESULTS One of the processes of rupturing thin blood vessels, which are an essential component of the bruising mechanism, was observed and recorded as a movie. The soft tissue surrounding the thin blood vessel extended in a plane perpendicular to the compressive contact force. Subsequently, the thin blood vessel was pulled into a straight configuration. Next, it was stretched in the axial direction and finally ruptured. CONCLUSION The results obtained indicate that the extension of the surrounding tissue in the direction perpendicular to the contact force as well as the extension of the thin blood vessels are important factors in the bruising mechanism, which must be reproduced by FEM simulation to estimate the thresholds.
Collapse
Affiliation(s)
- Tatsuo Fujikawa
- Department of Mechanical Engineering, College of Engineering, Nihon University, 1 Nakagawara, Tokusada, Tamuramachi, Koriyama, 963-8642, Japan.
| | - Yoji Yamada
- Department of Mechanical System Engineering, Nagoya University, Furo-Cho, Chikusa-Ku, Nagoya, 464-8603, Japan
| |
Collapse
|
17
|
Breish F, Hamm C, Andresen S. Nature's Load-Bearing Design Principles and Their Application in Engineering: A Review. Biomimetics (Basel) 2024; 9:545. [PMID: 39329566 PMCID: PMC11430629 DOI: 10.3390/biomimetics9090545] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/31/2024] [Revised: 09/02/2024] [Accepted: 09/05/2024] [Indexed: 09/28/2024] Open
Abstract
Biological structures optimized through natural selection provide valuable insights for engineering load-bearing components. This paper reviews six key strategies evolved in nature for efficient mechanical load handling: hierarchically structured composites, cellular structures, functional gradients, hard shell-soft core architectures, form follows function, and robust geometric shapes. The paper also discusses recent research that applies these strategies to engineering design, demonstrating their effectiveness in advancing technical solutions. The challenges of translating nature's designs into engineering applications are addressed, with a focus on how advancements in computational methods, particularly artificial intelligence, are accelerating this process. The need for further development in innovative material characterization techniques, efficient modeling approaches for heterogeneous media, multi-criteria structural optimization methods, and advanced manufacturing techniques capable of achieving enhanced control across multiple scales is underscored. By highlighting nature's holistic approach to designing functional components, this paper advocates for adopting a similarly comprehensive methodology in engineering practices to shape the next generation of load-bearing technical components.
Collapse
Affiliation(s)
- Firas Breish
- Alfred-Wegener-Institut Helmholtz-Zentrum für Polar- und Meeresforschung, 27570 Bremerhaven, Germany
| | - Christian Hamm
- Alfred-Wegener-Institut Helmholtz-Zentrum für Polar- und Meeresforschung, 27570 Bremerhaven, Germany
| | - Simone Andresen
- Alfred-Wegener-Institut Helmholtz-Zentrum für Polar- und Meeresforschung, 27570 Bremerhaven, Germany
| |
Collapse
|
18
|
Clayton JD. Universal phase-field mixture representation of thermodynamics and shock-wave mechanics in porous soft biologic continua. Phys Rev E 2024; 110:035001. [PMID: 39425387 DOI: 10.1103/physreve.110.035001] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/10/2024] [Accepted: 08/07/2024] [Indexed: 10/21/2024]
Abstract
A continuum mixture theory is formulated for large deformations, thermal effects, phase interactions, and degradation of soft biologic tissues suitable at high pressures and low to very high strain rates. Tissues consist of one or more solid and fluid phases and can demonstrate nonlinear anisotropic elastic, viscoelastic, thermoelastic, and poroelastic physics. Under extreme deformations or shock loading, tissues may fracture, tear, or rupture. Existing models do not account for all physics simultaneously, and most poromechanics and soft-tissue models assume incompressibility of some or all constituents, generally inappropriate for modeling shock waves or extreme compressions. Motivated by these prior limitations, a thermodynamically consistent formulation that combines a continuum theory of mixtures, compressible nonlinear anisotropic thermoelasticity, viscoelasticity, and phase-field mechanics of fracture is constructed to resolve the pertinent physics. A metric tensor of generalized Finsler space supplies geometric insight on effects of rearrangements of microstructure, for example degradation, growth, and remodeling. Shocks are modeled as singular surfaces. Hugoniot states and shock decay are analyzed: Solutions account for concurrent viscoelasticity, fracture, and interphase momentum and energy exchange not all contained in previous analyses. Suitability of the framework for representing blood, skeletal muscle, and liver is demonstrated by agreement with experimental data and observations across a range of loading rates and pressures. Insight into previously unresolved physics is obtained, for example importance of rate sensitivity of damage and quantification of effects of dissipation from viscoelasticity and phase interactions on shock decay.
Collapse
Affiliation(s)
- J D Clayton
- Terminal Effects Division, DEVCOM ARL, Aberdeen Proving Ground, Maryland 21005-5066, USA
| |
Collapse
|
19
|
Akbarzadeh Khorshidi M, Bose S, Watschke B, Mareena E, Lally C. Characterisation of human penile tissue properties using experimental testing combined with multi-target inverse finite element modelling. Acta Biomater 2024; 184:226-238. [PMID: 38945188 DOI: 10.1016/j.actbio.2024.06.035] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/04/2024] [Revised: 06/05/2024] [Accepted: 06/24/2024] [Indexed: 07/02/2024]
Abstract
This paper presents an inverse finite element (FE) approach aimed at estimating multi-layered human penile tissues. The inverse FE approach integrates experimental force-displacement and boundary deformation data of penile tissues with a developed FE model and uses new experimental data on human penile tissue. The experimental study encompasses whole organ plate-compression tests and individual layer tensile and compression tests, providing comprehensive insights into the tissue's mechanical behaviour. The biomechanical characterisation of penile tissue is of crucial significance for understanding its mechanical behaviour under various physiological and pathological conditions. The FE model is constructed using the realistic geometry of the penile segment and appropriate constitutive models for each tissue layer to leverage the accuracy and consistency of the model. Through systematic variation of tissue parameters in the inverse FE algorithm, simulations achieve the best match with both force-displacement and deformed boundary results obtained from the whole organ plate-compression tests. Test results from individual tissue layers are also utilised to assess the estimated parameters. The proposed inverse FE approach allows for the estimation of penile tissue parameters with high precision and reliability, shedding light on the mechanical properties of this complex biological organ. This work has applications not only in urology but also for researchers in various disciplines of biomechanics. As a result, our study contributes to advancing the understanding of human penile tissue mechanics whilst the methodology could also be applied to a range of other soft biological tissues. STATEMENT OF SIGNIFICANCE: This research uses a multi-target inverse finite element (FE) approach for estimating the material parameters of human penile tissues. By integrating experimental data and a realistic FE model, this study achieves high-precision constitutive model parameter estimation, offering key insights into penile tissue mechanics under various loading conditions. The significance of this work lies in the use of this inverse FE approach for fresh-frozen human penile tissues, to identify the mechanical properties and constitutive models for both segregated tunica albuginea and corpus cavernosum as well as intact penile tissue segments. The study's scientific impact lies in its advancement of the understanding of human urological tissue mechanics, impacting researchers and clinicians alike.
Collapse
Affiliation(s)
- Majid Akbarzadeh Khorshidi
- Trinity Centre for Biomedical Engineering, Trinity Biomedical Sciences Institute, Trinity College Dublin, Dublin 2, Ireland; Department of Mechanical, Manufacturing and Biomedical Engineering, School of Engineering, Trinity College Dublin, Dublin 2, Ireland; Advanced Materials and BioEngineering Research Centre (AMBER), Royal College of Surgeons in Ireland and Trinity College Dublin, Dublin 2, Ireland
| | - Shirsha Bose
- Trinity Centre for Biomedical Engineering, Trinity Biomedical Sciences Institute, Trinity College Dublin, Dublin 2, Ireland; Department of Mechanical, Manufacturing and Biomedical Engineering, School of Engineering, Trinity College Dublin, Dublin 2, Ireland; Advanced Materials and BioEngineering Research Centre (AMBER), Royal College of Surgeons in Ireland and Trinity College Dublin, Dublin 2, Ireland
| | - Brian Watschke
- Urology, Boston Scientific Corp, Inc, Minnetonka, MN, USA
| | - Evania Mareena
- Urology, Boston Scientific Corp, Inc, Clonmel Co, Tipperary, Ireland
| | - Caitríona Lally
- Trinity Centre for Biomedical Engineering, Trinity Biomedical Sciences Institute, Trinity College Dublin, Dublin 2, Ireland; Department of Mechanical, Manufacturing and Biomedical Engineering, School of Engineering, Trinity College Dublin, Dublin 2, Ireland; Advanced Materials and BioEngineering Research Centre (AMBER), Royal College of Surgeons in Ireland and Trinity College Dublin, Dublin 2, Ireland.
| |
Collapse
|
20
|
Zhang M, Zhao L, Tian F, Zhao X, Zhang Y, Yang X, Huang W, Yu R. Bionic Artificial Skin Based on Self-Healable Ionogel Composites with Tailored Mechanics and Robust Interfaces. ADVANCED MATERIALS (DEERFIELD BEACH, FLA.) 2024; 36:e2405776. [PMID: 38966888 DOI: 10.1002/adma.202405776] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 04/23/2024] [Revised: 06/28/2024] [Indexed: 07/06/2024]
Abstract
Bionic artificial skin which imitates the features and functions of human skin, has broad applications in wearable human-machine interfaces. However, equipping artificial materials with skin-like mechanical properties, self-healing ability, and high sensitivity remains challenging. Here, inspired by the structure of human skin, an artificial skin based on ionogel composites with tailored mechanical properties and robust interface is prepared. Combining finite element analysis and direct ink writing (DIW) 3D printing technology, an ionogel composite with a rigid skeleton and an ionogel matrix is precisely designed and fabricated, realizing the mechanical anisotropy and nonlinear mechanical response that accurately mimic human skin. Robust interface is created through co-curing of the skeleton and matrix resins, significantly enhancing the stability of the composite. The realization of self-healing ability and resistance to crack growth further ensure the remarkable durability of the artificial skin for sensing application. In summary, the bionic artificial skin mimics the characteristics of human skin, including mechanical anisotropy, nonlinear mechanical response, self-healing capability, durability and high sensitivity when applied as flexible sensors. These strategies provide strong support for the fabrication of tissue-like materials with adaptive mechanical behaviors.
Collapse
Affiliation(s)
- Manwen Zhang
- Key laboratory of science and technology on high-tech polymer materials, Institute of Chemistry, Chinese Academy of Sciences, Beijing, 100190, P. R. China
- School of Chemical Sciences, University of Chinese Academy of Sciences, Beijing, 101408, P. R. China
| | - Lingyu Zhao
- Key laboratory of science and technology on high-tech polymer materials, Institute of Chemistry, Chinese Academy of Sciences, Beijing, 100190, P. R. China
- School of Chemical Sciences, University of Chinese Academy of Sciences, Beijing, 101408, P. R. China
| | - Feng Tian
- Key laboratory of science and technology on high-tech polymer materials, Institute of Chemistry, Chinese Academy of Sciences, Beijing, 100190, P. R. China
- School of Chemical Sciences, University of Chinese Academy of Sciences, Beijing, 101408, P. R. China
| | - Xiaojuan Zhao
- Key laboratory of science and technology on high-tech polymer materials, Institute of Chemistry, Chinese Academy of Sciences, Beijing, 100190, P. R. China
- School of Chemical Sciences, University of Chinese Academy of Sciences, Beijing, 101408, P. R. China
| | - Ying Zhang
- Key laboratory of science and technology on high-tech polymer materials, Institute of Chemistry, Chinese Academy of Sciences, Beijing, 100190, P. R. China
- School of Chemical Sciences, University of Chinese Academy of Sciences, Beijing, 101408, P. R. China
| | - Xin Yang
- Key laboratory of science and technology on high-tech polymer materials, Institute of Chemistry, Chinese Academy of Sciences, Beijing, 100190, P. R. China
- School of Chemical Sciences, University of Chinese Academy of Sciences, Beijing, 101408, P. R. China
| | - Wei Huang
- Key laboratory of science and technology on high-tech polymer materials, Institute of Chemistry, Chinese Academy of Sciences, Beijing, 100190, P. R. China
- School of Chemical Sciences, University of Chinese Academy of Sciences, Beijing, 101408, P. R. China
| | - Ran Yu
- Key laboratory of science and technology on high-tech polymer materials, Institute of Chemistry, Chinese Academy of Sciences, Beijing, 100190, P. R. China
- School of Chemical Sciences, University of Chinese Academy of Sciences, Beijing, 101408, P. R. China
| |
Collapse
|
21
|
Antarvedi Goda B, Ma Z, Fregonese S, Bacca M. Cutting soft matter: scaling relations controlled by toughness, friction, and wear. SOFT MATTER 2024. [PMID: 39028024 DOI: 10.1039/d4sm00279b] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 07/20/2024]
Abstract
Cutting mechanics of soft solids is gaining rapid attention thanks to its promising benefits in material characterization and other applications. However, a full understanding of the physical phenomena is still missing, and several questions remain outstanding. E.g.: How can we directly and reliably measure toughness from cutting experiments? What is the role of blade sharpness? In this paper, we explore the simple problem of wire cutting, where blade sharpness is only defined by the wire radius. Through finite element analysis, we obtain a simple scaling relation between the wire radius and the steady-state cutting force per unit sample thickness. The cutting force is independent of the wire radius if the latter is below a transition length, while larger radii produce a linear force-radius correlation. The minimum cutting force, for small radii, is given by cleavage toughness, i.e., the surface energy required to break covalent bonds in the crack plane. The force-radius slope is instead given by the wear shear strength in the material. Via cutting experiments on polyacrylamide gels, we find that the magnitude of shear strength is close to the work of fracture of the material, i.e., the critical strain energy density required to break a pristine sample in uniaxial tension. The work of fracture characterizes the toughening contribution from the fracture process zone (FPZ), which adds to cleavage toughness. Our study provides two important messages, that answer the above questions: toughness can be estimated from wire-cutting experiments from the intercept of the force-radius linear correlation, as previously explored. However, as we discovered, this only estimates cleavage toughness. Additionally, the force-radius slope is correlated with the work of fracture, giving an estimation of the dissipative contributions from the FPZ.
Collapse
Affiliation(s)
- Bharath Antarvedi Goda
- Mechanical Engineering Department, University of British Columbia, Vancouver, BC V6T1Z4, Canada.
| | - Zhenwei Ma
- Department of Pathology and Laboratory Medicine, University of British Columbia, Vancouver, BC V6T 2B5, Canada.
| | - Stefano Fregonese
- Mechanical Engineering Department, University of British Columbia, Vancouver, BC V6T1Z4, Canada.
| | - Mattia Bacca
- Mechanical Engineering Department, University of British Columbia, Vancouver, BC V6T1Z4, Canada.
| |
Collapse
|
22
|
Shrestha P, Geffner C, Jaffey M, Wu Z, Iapichino M, Bacca M, Stoeber B. Force decomposition and toughness estimation from puncture experiments in soft solids. SOFT MATTER 2024; 20:5377-5388. [PMID: 38932556 DOI: 10.1039/d4sm00211c] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/28/2024]
Abstract
Several medical applications, like drug delivery and biosensing, are critically preceded by the insertion of needles and microneedles into biological tissue. However, the mechanical process of needle insertions, especially at high velocities, is currently not fully understood. Here, we explore the insertion of hollow needles into transparent silicone samples with an insertion velocity v ranging from 0.1 mm s-1 to 2.3 m s-1 (with needle radius R = 101.5 μm, thus strain rates ∼v/R ranging from 1 s-1 to 2.3 × 104 s-1). We use a double-insertion method, where the needle is inserted and re-inserted at the same location, to estimate the fracture properties of the material. The deflection of the specimen's free surface is found to be different between insertion and re-insertion experiments for identical needle positions, which is associated with different force magnitudes between insertion/reinsertion. This aspect was previously neglected in the original double-insertion method, thus here we develop a method based on imaging, image analyses and force measurements to decompose the measured force into individual force components, including deflection force Fd, frictional and spreading force Ff + Fs, and cutting force Ft. We estimate that the toughness Γ of our silicone samples, calculated using the cutting force Ft and the crack dimensions, increases with needle velocity, and ranges within observed values in previous literature for the same material and for some soft biological materials. In addition to toughness Γ, other parameters, such as critical force Fc and mechanical work Wc, also show strain-rate dependence, suggesting tissue stiffening, due to accumulated strain energy, at high speeds.
Collapse
Affiliation(s)
- Pranav Shrestha
- Department of Mechanical Engineering, The University of British Columbia, 2054-6250 Applied Science Lane, Vancouver, British Columbia, V6T 1Z4, Canada.
| | - Curtis Geffner
- Department of Mechanical Engineering, The University of British Columbia, 2054-6250 Applied Science Lane, Vancouver, British Columbia, V6T 1Z4, Canada.
| | - Matthew Jaffey
- Department of Mechanical Engineering, The University of British Columbia, 2054-6250 Applied Science Lane, Vancouver, British Columbia, V6T 1Z4, Canada.
| | - Zhongnan Wu
- Department of Mechanical Engineering, The University of British Columbia, 2054-6250 Applied Science Lane, Vancouver, British Columbia, V6T 1Z4, Canada.
| | - Martina Iapichino
- Department of Mechanical Engineering, The University of British Columbia, 2054-6250 Applied Science Lane, Vancouver, British Columbia, V6T 1Z4, Canada.
| | - Mattia Bacca
- Department of Mechanical Engineering, The University of British Columbia, 2054-6250 Applied Science Lane, Vancouver, British Columbia, V6T 1Z4, Canada.
| | - Boris Stoeber
- Department of Mechanical Engineering, The University of British Columbia, 2054-6250 Applied Science Lane, Vancouver, British Columbia, V6T 1Z4, Canada.
- Department of Electrical and Computer Engineering, The University of British Columbia, 2332 Main Mall, Vancouver, British Columbia, V6T 1Z4, Canada
| |
Collapse
|
23
|
Hsieh CH, Liu YX, Chen PY, Fang HW. Zigzag Barbed Polydioxanone Thread Implantation and Evaluation Using Polydimethylsiloxane Model to Simulate Thread Migration in Tissue. Polymers (Basel) 2024; 16:1785. [PMID: 39000641 PMCID: PMC11244147 DOI: 10.3390/polym16131785] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/09/2024] [Revised: 06/17/2024] [Accepted: 06/21/2024] [Indexed: 07/17/2024] Open
Abstract
Facial lifting with polydioxanone barbed threads has been widely used in aesthetic treatment for years. However, gravity resists the thread and continuously pulls the face downward. This study aims to determine methods to lift the skin more efficiently with longer longevity. The quality of the thread is important and is defined by the pulling and pullout strengths. Moreover, the method of using threads is also important. We compared five thread-implantation techniques and six angles for the V-shaped implantation methods using a polydimethylsiloxane model to simulate thread migration in tissues. The results of the simulated thread-lift techniques can provide valuable information for physicians, enabling a more precise design of facelift surgery techniques.
Collapse
Affiliation(s)
- Chia-Hsien Hsieh
- Department of Chemical Engineering and Biotechnology, National Taipei University of Technology, No. 1, Sec. 3, Zhongxiao E. Rd., Taipei 10608, Taiwan; (C.-H.H.); (Y.-X.L.); (P.-Y.C.)
| | - Yi-Xin Liu
- Department of Chemical Engineering and Biotechnology, National Taipei University of Technology, No. 1, Sec. 3, Zhongxiao E. Rd., Taipei 10608, Taiwan; (C.-H.H.); (Y.-X.L.); (P.-Y.C.)
- High-Value Biomaterials Research and Commercialization Center, National Taipei University of Technology, No. 1, Sec. 3, Zhongxiao E. Rd., Taipei 10608, Taiwan
| | - Pei-Yu Chen
- Department of Chemical Engineering and Biotechnology, National Taipei University of Technology, No. 1, Sec. 3, Zhongxiao E. Rd., Taipei 10608, Taiwan; (C.-H.H.); (Y.-X.L.); (P.-Y.C.)
- High-Value Biomaterials Research and Commercialization Center, National Taipei University of Technology, No. 1, Sec. 3, Zhongxiao E. Rd., Taipei 10608, Taiwan
| | - Hsu-Wei Fang
- Department of Chemical Engineering and Biotechnology, National Taipei University of Technology, No. 1, Sec. 3, Zhongxiao E. Rd., Taipei 10608, Taiwan; (C.-H.H.); (Y.-X.L.); (P.-Y.C.)
- High-Value Biomaterials Research and Commercialization Center, National Taipei University of Technology, No. 1, Sec. 3, Zhongxiao E. Rd., Taipei 10608, Taiwan
- Institute of Biomedical Engineering and Nanomedicine, National Health Research Institutes, No. 35, Keyan Road, Zhunan Town 35053, Miaoli County, Taiwan
| |
Collapse
|
24
|
Wang X, Li K, Yuan Y, Zhang N, Zou Z, Wang Y, Yan S, Li X, Zhao P, Li Q. Nonlinear Elasticity of Blood Vessels and Vascular Grafts. ACS Biomater Sci Eng 2024; 10:3631-3654. [PMID: 38815169 DOI: 10.1021/acsbiomaterials.4c00326] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 06/01/2024]
Abstract
The transplantation of vascular grafts has emerged as a prevailing approach to address vascular disorders. However, the development of small-diameter vascular grafts is still in progress, as they serve in a more complicated mechanical environment than their counterparts with larger diameters. The biocompatibility and functional characteristics of small-diameter vascular grafts have been well developed; however, mismatch in mechanical properties between the vascular grafts and native arteries has not been accomplished, which might facilitate the long-term patency of small-diameter vascular grafts. From a point of view in mechanics, mimicking the nonlinear elastic mechanical behavior exhibited by natural blood vessels might be the state-of-the-art in designing vascular grafts. This review centers on elucidating the nonlinear elastic behavior of natural blood vessels and vascular grafts. The biological functionality and limitations associated with as-reported vascular grafts are meticulously reviewed and the future trajectory for fabricating biomimetic small-diameter grafts is discussed. This review might provide a different insight from the traditional design and fabrication of artificial vascular grafts.
Collapse
Affiliation(s)
- Xiaofeng Wang
- School of Mechanics and Safety Engineering, National Center for International Research of Micro-nano Molding Technology, Zhengzhou University, Zhengzhou 450001, China
- The State Key Laboratory of Fluid Power and Mechatronic Systems, Zhejiang University, Hangzhou 310027, China
| | - Kecheng Li
- School of Mechanics and Safety Engineering, National Center for International Research of Micro-nano Molding Technology, Zhengzhou University, Zhengzhou 450001, China
| | - Yuan Yuan
- School of Mechanics and Safety Engineering, National Center for International Research of Micro-nano Molding Technology, Zhengzhou University, Zhengzhou 450001, China
| | - Ning Zhang
- School of Mechanics and Safety Engineering, National Center for International Research of Micro-nano Molding Technology, Zhengzhou University, Zhengzhou 450001, China
| | - Zifan Zou
- School of Mechanics and Safety Engineering, National Center for International Research of Micro-nano Molding Technology, Zhengzhou University, Zhengzhou 450001, China
| | - Yun Wang
- School of Mechanics and Safety Engineering, National Center for International Research of Micro-nano Molding Technology, Zhengzhou University, Zhengzhou 450001, China
| | - Shujie Yan
- School of Mechanics and Safety Engineering, National Center for International Research of Micro-nano Molding Technology, Zhengzhou University, Zhengzhou 450001, China
| | - Xiaomeng Li
- School of Mechanics and Safety Engineering, National Center for International Research of Micro-nano Molding Technology, Zhengzhou University, Zhengzhou 450001, China
| | - Peng Zhao
- The State Key Laboratory of Fluid Power and Mechatronic Systems, Zhejiang University, Hangzhou 310027, China
| | - Qian Li
- School of Mechanics and Safety Engineering, National Center for International Research of Micro-nano Molding Technology, Zhengzhou University, Zhengzhou 450001, China
| |
Collapse
|
25
|
Sachs D, Jakob R, Thumm B, Bajka M, Ehret AE, Mazza E. Sustained Physiological Stretch Induces Abdominal Skin Growth in Pregnancy. Ann Biomed Eng 2024; 52:1576-1590. [PMID: 38424309 PMCID: PMC11081934 DOI: 10.1007/s10439-024-03472-6] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/14/2023] [Accepted: 02/11/2024] [Indexed: 03/02/2024]
Abstract
Supraphysiological stretches are exploited in skin expanders to induce tissue growth for autologous implants. As pregnancy is associated with large levels of sustained stretch, we investigated whether skin growth occurs in pregnancy. Therefore, we combined a mechanical model of skin and the observations from suction experiments on several body locations of five pregnant women at different gestational ages. The measurements show a continuous increase in stiffness, with the largest change observed during the last trimester. A comparison with numerical simulations indicates that the measured increase in skin stiffness is far below the level expected for the corresponding deformation of abdominal skin. A new set of simulations accounting for growth could rationalize all observations. The predicted amount of tissue growth corresponds to approximately 40% area increase before delivery. The results of the simulations also offered the opportunity to investigate the biophysical cues present in abdominal skin along gestation and to compare them with those arising in skin expanders. Alterations of the skin mechanome were quantified, including tissue stiffness, hydrostatic and osmotic pressure of the interstitial fluid, its flow velocity and electrical potential. The comparison between pregnancy and skin expansion highlights similarities as well as differences possibly influencing growth and remodeling.
Collapse
Affiliation(s)
- David Sachs
- Institute for Mechanical Systems, ETH Zürich, Zurich, Switzerland.
| | - Raphael Jakob
- Institute for Mechanical Systems, ETH Zürich, Zurich, Switzerland
| | - Bettina Thumm
- Institute for Mechanical Systems, ETH Zürich, Zurich, Switzerland
| | - Michael Bajka
- Department of Obstetrics and Gynecology, University Hospital of Zurich, Zurich, Switzerland
| | - Alexander E Ehret
- Institute for Mechanical Systems, ETH Zürich, Zurich, Switzerland
- Swiss Federal Laboratories for Materials Science and Technology, Dubendorf, Switzerland
| | - Edoardo Mazza
- Institute for Mechanical Systems, ETH Zürich, Zurich, Switzerland
- Swiss Federal Laboratories for Materials Science and Technology, Dubendorf, Switzerland
| |
Collapse
|
26
|
Barros-Oliveira CS, de Jesus MJM, Campos VC, Salvatori R, de Souza Araújo AA, Neto RFS, Bartke A, Batista VO, Schneider A, Villar-Gouy KR, Masternak MM, Leal ÂC, Santos LB, Oliveira CRP, Santos EG, Oliveira Simões DA, de Santana Silva B, Aguiar-Oliveira MH. Skin assessment in congenital untreated isolated GH deficiency. Endocrine 2024; 84:1116-1124. [PMID: 38703329 DOI: 10.1007/s12020-024-03840-1] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 01/18/2024] [Accepted: 04/16/2024] [Indexed: 05/06/2024]
Abstract
PURPOSE The separation between the inside and outside through the skin was fundamental for the evolution of prevertebrates, which grow through extrapituitary circuits, to vertebrates, which grow through the somatotrophic axis, namely pituitary growth hormone (GH). and circulating IGF1.Individuals with untreated isolated growth hormone (GH) deficiency (IGHD) due to a mutation in the GH-releasing hormone receptor (GHRH) gene, residing in Itabaianinha, Brazil, are vulnerable to skin cancer and have reduced sweating. However other aspects of their skin physiology are still unknown. Our objectives were to evaluate the number of skin cancers, skin aging, and functional aspects of the skin in this IGHD cohort. METHODS Twenty-six IGHD individuals and 26 controls matched by age, sex, ethnicity, and occupation were submitted to a biochemical, dermatological and a functional skin assessment by the Multi Probe Adapter Cutometer® MPA 580. RESULTS There was no difference in the number of skin cancers and in the degrees of photodamage between the groups. The melanin content in the forearm was similar between the groups but was lower in the buttocks (p = 0.005), as well as skin resistance (p < 0.0001) and elasticity (p = 0.003), lower in the IGHD. There was no difference in hydration and sebum content between the two groups. CONCLUSION IGHD is apparently associated with a neutral profile in terms of skin cancer and photodamage, with similar melanin on the forearm and lower buttocks, lower skin resistance and elasticity, with hydration and sebum similar to controls.
Collapse
Affiliation(s)
- Cynthia S Barros-Oliveira
- Division of Endocrinology, Health Sciences Graduate Program, Federal University of Sergipe, Aracaju, 49060-100, Sergipe, Brazil
| | - Maria Joseli Melo de Jesus
- Pharmaceutical Testing Laboratory, Department of Pharmacy, Postgraduate Program in Pharmaceutical Sciences, Federal University of Sergipe, 49100000, Aracaju, Sergipe, Brazil
| | - Viviane C Campos
- Division of Endocrinology, Health Sciences Graduate Program, Federal University of Sergipe, Aracaju, 49060-100, Sergipe, Brazil
| | - Roberto Salvatori
- Division of Endocrinology, Diabetes and Metabolism, Department of Medicine, The Johns Hopkins University School of Medicine, Baltimore, Maryland, 21287, USA
| | - Adriano Antunes de Souza Araújo
- Pharmaceutical Testing Laboratory, Department of Pharmacy, Postgraduate Program in Pharmaceutical Sciences, Federal University of Sergipe, 49100000, Aracaju, Sergipe, Brazil
- Health Sciences Graduate Program, Federal University of Sergipe, Aracaju, 49060-100, Sergipe, Brazil
| | | | - Andrzej Bartke
- Southern Illinois University School of Medicine, Department of Internal Medicine, 801 N. Rutledge, P.O. Box 19628, Springfield, Illinois, 62702, USA
| | - Vanderlan O Batista
- Division of Psychiatry, Health Sciences Graduate Program, Federal University of Sergipe, Aracaju, 49060-100, Sergipe, Brazil
| | - Augusto Schneider
- Faculty of Nutrition, Federal University of Pelotas, Pelotas, 96010-610, Brazil
| | - Keila R Villar-Gouy
- Division of Endocrinology, Health Sciences Graduate Program, Federal University of Sergipe, Aracaju, 49060-100, Sergipe, Brazil
| | - Michal M Masternak
- Burnett School of Biomedical Sciences, College of Medicine, University of Central Florida, Orlando, 32826 FL, USA
- Department of Head and Neck Surgery, Poznan University of Medical Sciences, Poznan, 60-512, Poland
| | - Ângela C Leal
- Division of Endocrinology, Health Sciences Graduate Program, Federal University of Sergipe, Aracaju, 49060-100, Sergipe, Brazil
| | - Lucas B Santos
- Division of Endocrinology, Health Sciences Graduate Program, Federal University of Sergipe, Aracaju, 49060-100, Sergipe, Brazil
| | - Carla R P Oliveira
- Division of Endocrinology, Health Sciences Graduate Program, Federal University of Sergipe, Aracaju, 49060-100, Sergipe, Brazil
| | - Elenilde G Santos
- Division of Endocrinology, Health Sciences Graduate Program, Federal University of Sergipe, Aracaju, 49060-100, Sergipe, Brazil
| | - Davi A Oliveira Simões
- Division of Endocrinology, Health Sciences Graduate Program, Federal University of Sergipe, Aracaju, 49060-100, Sergipe, Brazil
| | - Bruno de Santana Silva
- Division of Dermatology, Department of Medicine, Federal University of Sergipe, Aracaju, 49060-100, Sergipe, Brazil
| | - Manuel H Aguiar-Oliveira
- Division of Endocrinology, Health Sciences Graduate Program, Federal University of Sergipe, Aracaju, 49060-100, Sergipe, Brazil.
| |
Collapse
|
27
|
Zhou M, González PJ, Van Haasterecht L, Soylu A, Mihailovski M, Van Zuijlen P, Groot ML. Uniaxial mechanical stretch properties correlated with three-dimensional microstructure of human dermal skin. Biomech Model Mechanobiol 2024; 23:911-925. [PMID: 38324073 PMCID: PMC11101527 DOI: 10.1007/s10237-023-01813-3] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/28/2023] [Accepted: 12/30/2023] [Indexed: 02/08/2024]
Abstract
The intact and healthy skin forms a barrier to the outside world and protects the body from mechanical impact. The skin is a complex structure with unique mechano-elastic properties. To better direct the design of biomimetic materials and induce skin regeneration in wounds with optimal outcome, more insight is required in how the mechano-elastic properties emerge from the skin's main constituents, collagen and elastin fibers. Here, we employed two-photon excited autofluorescence and second harmonic generation microscopy to characterize collagen and elastin fibers in 3D in 24 human dermis skin samples. Through uniaxial stretching experiments, we derive uni-directional mechanical properties from resultant stress-strain curves, including the initial Young's modulus, elastic Young's modulus, maximal stress, and maximal and mid-strain values. The stress-strain curves show a large variation, with an average Young's modules in the toe and linear regions of 0.1 MPa and 21 MPa. We performed a comprehensive analysis of the correlation between the key mechanical properties with age and with microstructural parameters, e.g., fiber density, thickness, and orientation. Age was found to correlate negatively with Young's modulus and collagen density. Moreover, real-time monitoring during uniaxial stretching allowed us to observe changes in collagen and elastin alignment. Elastin fibers aligned significantly in both the heel and linear regions, and the collagen bundles engaged and oriented mainly in the linear region. This research advances our understanding of skin biomechanics and yields input for future first principles full modeling of skin tissue.
Collapse
Affiliation(s)
- Mengyao Zhou
- Faculty of Science, Department of Physics, Laserlab, Vrije Universiteit Amsterdam, De Boelelaan 1105, 1081HV, Amsterdam, The Netherlands.
| | - Patrick José González
- Faculty of Science, Department of Physics, Laserlab, Vrije Universiteit Amsterdam, De Boelelaan 1105, 1081HV, Amsterdam, The Netherlands
| | - Ludo Van Haasterecht
- Faculty of Science, Department of Physics, Laserlab, Vrije Universiteit Amsterdam, De Boelelaan 1105, 1081HV, Amsterdam, The Netherlands
- Burn Center and Department of Plastic, Reconstructive and Hand Surgery, Red Cross Hospital, Mozartstraat 201, 1962 AB, Beverwijk, The Netherlands
- Department of Plastic, Reconstructive and Hand Surgery, Amsterdam University Medical Center (UMC), Location Vrije Universiteit Amsterdam, De Boelelaan 1117, 1081 HV, Amsterdam, The Netherlands
| | - Alperen Soylu
- Faculty of Science, Department of Physics, Laserlab, Vrije Universiteit Amsterdam, De Boelelaan 1105, 1081HV, Amsterdam, The Netherlands
| | - Maria Mihailovski
- Faculty of Science, Department of Physics, Laserlab, Vrije Universiteit Amsterdam, De Boelelaan 1105, 1081HV, Amsterdam, The Netherlands
| | - Paul Van Zuijlen
- Burn Center and Department of Plastic, Reconstructive and Hand Surgery, Red Cross Hospital, Mozartstraat 201, 1962 AB, Beverwijk, The Netherlands
- Department of Plastic, Reconstructive and Hand Surgery, Amsterdam University Medical Center (UMC), Location Vrije Universiteit Amsterdam, De Boelelaan 1117, 1081 HV, Amsterdam, The Netherlands
- Pediatric Surgical Centre, Emma Children's Hospital, Amsterdam University Medical Center (UMC), Location University of Amsterdam, Meibergdreef 9, Amsterdam, The Netherlands
- Amsterdam Movement Sciences (AMS) Institute, Amsterdam University Medical Center (UMC), Location Vrije Universiteit Amsterdam, Meibergdreef 9, Amsterdam, The Netherlands
| | - Marie Louise Groot
- Faculty of Science, Department of Physics, Laserlab, Vrije Universiteit Amsterdam, De Boelelaan 1105, 1081HV, Amsterdam, The Netherlands
| |
Collapse
|
28
|
Chittajallu SNSH, Gururani H, Jakati S, Basu S, Vaddavalli PK, Tse KM, Chinthapenta V. Investigation of mechanical strength and structure of corneal graft-host junction. Heliyon 2024; 10:e30871. [PMID: 38784531 PMCID: PMC11112333 DOI: 10.1016/j.heliyon.2024.e30871] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/20/2024] [Accepted: 05/07/2024] [Indexed: 05/25/2024] Open
Abstract
Dehiscence is a common complication of corneal transplant surgery involving separating the graft from the host eye. The present article aims to investigate fundamental insights into the mechanical and structural aspects of the graft-host junction (GHJ) of a graft that survived in a patient for 13 years after penetrating keratoplasty (PK). Additionally, it adopts the sutur retention strength (SRS) test procedure defined in ISO:7198-2016 and aims to provide a comprehensive test protocol to study the biomechanics of the GHJ in extracted PK buttons. A 9 mm corneal button with GHJ was extracted from a 46-year-old patient who underwent PK 13 years back. The strength of the GHJ was quantified using the SRS test. Corresponding control results were obtained from the SRS tests of a corneoscleral button with no history of any refractive procedure. Birefringence, histological, and scanning electron microscopy (SEM) imaging were used to visualize the microstructural details of the GHJ. The strength of the GHJ was observed to be ten times lower than the native cornea. Histopathological features, such as fragmented Bowman's layer, and fibrosis with a clear demarcation line between host and graft tissue, were observed at the GHJ, suggesting a weak bond across the GHJ. The low strength of the GHJ in PK indicates the high susceptibility of the GHJ towards wound dehiscence.
Collapse
Affiliation(s)
- Sai Naga Sri Harsha Chittajallu
- Department of Mechanical and Aerospace Engineering, Indian Institute of Technology Hyderabad, Hyderabad, India
- Department of Mechanical and Product Design Engineering, Swinburne University of Technology, Melbourne, Australia
- Centre for Technology Innovation, L V Prasad Eye Institute, Hyderabad, India
| | - Himanshu Gururani
- Department of Mechanical and Aerospace Engineering, Indian Institute of Technology Hyderabad, Hyderabad, India
| | - Saumya Jakati
- Ophthalmic Pathology Laboratory, LV Prasad Eye Institute, Hyderabad, India
| | - Sayan Basu
- Prof. Brien Holden Eye Research Centre, Hyderabad Eye Research Foundation, LV Prasad Eye Institute, Hyderabad, India
| | | | - Kwong Ming Tse
- Department of Mechanical and Product Design Engineering, Swinburne University of Technology, Melbourne, Australia
| | - Viswanath Chinthapenta
- Department of Mechanical and Aerospace Engineering, Indian Institute of Technology Hyderabad, Hyderabad, India
| |
Collapse
|
29
|
Gallagher S, Josyula K, Rahul, Kruger U, Gong A, Song A, Eschelbach E, Crawford D, Pham T, Sweet R, Parsey C, Norfleet J, De S. Mechanical behavior of full-thickness burn human skin is rate-independent. Sci Rep 2024; 14:11096. [PMID: 38750077 PMCID: PMC11096406 DOI: 10.1038/s41598-024-61556-8] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/09/2023] [Accepted: 05/07/2024] [Indexed: 05/18/2024] Open
Abstract
Skin tissue is recognized to exhibit rate-dependent mechanical behavior under various loading conditions. Here, we report that the full-thickness burn human skin exhibits rate-independent behavior under uniaxial tensile loading conditions. Mechanical properties, namely, ultimate tensile stress, ultimate tensile strain, and toughness, and parameters of Veronda-Westmann hyperelastic material law were assessed via uniaxial tensile tests. Univariate hypothesis testing yielded no significant difference (p > 0.01) in the distributions of these properties for skin samples loaded at three different rates of 0.3 mm/s, 2 mm/s, and 8 mm/s. Multivariate multiclass classification, employing a logistic regression model, failed to effectively discriminate samples loaded at the aforementioned rates, with a classification accuracy of only 40%. The median values for ultimate tensile stress, ultimate tensile strain, and toughness are computed as 1.73 MPa, 1.69, and 1.38 MPa, respectively. The findings of this study hold considerable significance for the refinement of burn care training protocols and treatment planning, shedding new light on the unique, rate-independent behavior of burn skin.
Collapse
Grants
- W911NF-17-2-0022 U.S. Army Futures Command, Combat Capabilities Development Command Soldier Center STTC
- W911NF-17-2-0022 U.S. Army Futures Command, Combat Capabilities Development Command Soldier Center STTC
- W911NF-17-2-0022 U.S. Army Futures Command, Combat Capabilities Development Command Soldier Center STTC
- W911NF-17-2-0022 U.S. Army Futures Command, Combat Capabilities Development Command Soldier Center STTC
- W912CG-20-2-0004 U.S. Army Futures Command, Combat Capabilities Development Command Soldier Center STTC
- W912CG-20-2-0004 U.S. Army Futures Command, Combat Capabilities Development Command Soldier Center STTC
- W912CG-20-2-0004 U.S. Army Futures Command, Combat Capabilities Development Command Soldier Center STTC
- W912CG-20-2-0004 U.S. Army Futures Command, Combat Capabilities Development Command Soldier Center STTC
- W912CG-20-2-0004 U.S. Army Futures Command, Combat Capabilities Development Command Soldier Center STTC
- W912CG-20-2-0004 U.S. Army Futures Command, Combat Capabilities Development Command Soldier Center STTC
- W911NF-17-2-0022 U.S. Army Futures Command, Combat Capabilities Development Command Soldier Center STTC
Collapse
Affiliation(s)
- Samara Gallagher
- Department of Mechanical, Aerospace, and Nuclear Engineering, Rensselaer Polytechnic Institute, Troy, NY, USA
- Center for Modeling, Simulation, and Imaging in Medicine, Rensselaer Polytechnic Institute, Troy, NY, USA
| | - Kartik Josyula
- Center for Modeling, Simulation, and Imaging in Medicine, Rensselaer Polytechnic Institute, Troy, NY, USA
| | - Rahul
- Center for Modeling, Simulation, and Imaging in Medicine, Rensselaer Polytechnic Institute, Troy, NY, USA.
| | - Uwe Kruger
- Center for Modeling, Simulation, and Imaging in Medicine, Rensselaer Polytechnic Institute, Troy, NY, USA
- Department of Biomedical Engineering, Rensselaer Polytechnic Institute, Troy, NY, USA
| | - Alex Gong
- Center for Research in Education and Simulation Technologies, University of Washington, Seattle, WA, USA
| | - Agnes Song
- Center for Research in Education and Simulation Technologies, University of Washington, Seattle, WA, USA
| | - Emily Eschelbach
- UW Medicine Regional Burn Center at Harborview Medical Center, University of Washington, Seattle, WA, USA
| | - David Crawford
- UW Medicine Regional Burn Center at Harborview Medical Center, University of Washington, Seattle, WA, USA
| | - Tam Pham
- UW Medicine Regional Burn Center at Harborview Medical Center, University of Washington, Seattle, WA, USA
| | - Robert Sweet
- Center for Research in Education and Simulation Technologies, University of Washington, Seattle, WA, USA
| | - Conner Parsey
- U.S. Army Combat Capabilities Development Command - Soldier Center, Simulation and Training Technology Center, Orlando, FL, USA
| | - Jack Norfleet
- U.S. Army Combat Capabilities Development Command - Soldier Center, Simulation and Training Technology Center, Orlando, FL, USA
| | - Suvranu De
- Department of Mechanical, Aerospace, and Nuclear Engineering, Rensselaer Polytechnic Institute, Troy, NY, USA
- Center for Modeling, Simulation, and Imaging in Medicine, Rensselaer Polytechnic Institute, Troy, NY, USA
- Department of Biomedical Engineering, Rensselaer Polytechnic Institute, Troy, NY, USA
| |
Collapse
|
30
|
Elsafty O, Berkey CA, Dauskardt RH. Insights and mechanics-driven modeling of human cutaneous impact injuries. J Mech Behav Biomed Mater 2024; 153:106456. [PMID: 38442507 DOI: 10.1016/j.jmbbm.2024.106456] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/02/2023] [Accepted: 02/03/2024] [Indexed: 03/07/2024]
Abstract
Cutaneous damage mechanisms related to dynamic fragment impacts are dependent on the impact angle, impact energy, and fragment characteristics including shape, volume, contact friction, and orientation. Understanding the cutaneous injury mechanism and its relationship to the fragment parameters is lacking compromising damage classification, treatment, and protection. Here we develop a high-fidelity dynamic mechanics-driven model for partial-thickness skin injuries and demonstrate the influence of fragment parameters on the injury mechanism and damage sequence. The model quantitatively predicts the wound shape, area, and depth into the skin layers for selected impact angles, kinetic energy density, and the fragment projectile type including shape and material. The detailed sequence of impact damage including epidermal tearing that occurs ahead of the fragments initial contact location, subsequent stripping of the epidermal/dermal junction, and crushing of the underlying dermis are revealed. We demonstrate that the fragment contact friction with skin plays a key role in redistributing impact energy affecting the extent of epidermal tearing and dermal crushing. Furthermore, projectile edges markedly affect injury severity dependent on the orientation of the edge during initial impact. The model provides a quantitative framework for understanding the detailed mechanisms of cutaneous damage and a basis for the design of protective equipment.
Collapse
Affiliation(s)
- Omar Elsafty
- Department of Mechanical Engineering, Stanford University, Stanford, CA, 94305, USA
| | - Christopher A Berkey
- Department of Materials Science and Engineering, Stanford University, Stanford, CA, 94305, USA
| | - Reinhold H Dauskardt
- Department of Materials Science and Engineering, Stanford University, Stanford, CA, 94305, USA.
| |
Collapse
|
31
|
Liang M, Liu Q, Chen Q, Wu Y, Wu C, Wang Y. Self-Assembling Gelatin-Curdlan Fibril Hydrogels for Oriented Neural Cell Growth. ACS APPLIED MATERIALS & INTERFACES 2024; 16:15741-15751. [PMID: 38518114 DOI: 10.1021/acsami.3c17379] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 03/24/2024]
Abstract
The ex vivo replication of the highly helical and fibril structures of load-bearing soft tissue is a challenging goal for the study of hydrogels. Inspired by nature, we prepared tissue-like physical gels based on curdlan and gelatin by self-assembly. The hybrid gels have a flexible fibril-matrix architecture, and the fibril orientation is highly tunable. The tensile strength of the gels can be tuned from ∼1.1 to ∼16.5 MPa. The coil-helix transition and nanofibril formation process in the self-assembly system was thoroughly investigated. These helical gels exhibit excellent cell compatibility, which supports adhesion and oriented growth of neural cells. Furthermore, the oriented nanofibrils in the gel are found to be associated with an upregulated expression of regeneration-related genes like N-cadherin (Cdh2) and neural growth factor (NGF). Owing to the strength and biomimetic structure, these gels have great potential in tissue engineering applications.
Collapse
Affiliation(s)
- Minting Liang
- Institute of Biomedicine, Department of Cell Biology, College of Life Science and Technology, Jinan University, Guangzhou 510632, People's Republic of China
| | - Qiuying Liu
- Institute of Biomedicine, Department of Cell Biology, College of Life Science and Technology, Jinan University, Guangzhou 510632, People's Republic of China
| | - Qunjie Chen
- Institute of Biomedicine, Department of Cell Biology, College of Life Science and Technology, Jinan University, Guangzhou 510632, People's Republic of China
| | - Yanting Wu
- Institute of Biomedicine, Department of Cell Biology, College of Life Science and Technology, Jinan University, Guangzhou 510632, People's Republic of China
| | - Chaoxi Wu
- Institute of Biomedicine, Department of Cell Biology, College of Life Science and Technology, Jinan University, Guangzhou 510632, People's Republic of China
| | - Yifei Wang
- Institute of Biomedicine, Department of Cell Biology, College of Life Science and Technology, Jinan University, Guangzhou 510632, People's Republic of China
| |
Collapse
|
32
|
Medina-Lombardero S, Bain C, Charlton L, Pellicoro A, Rocliffe H, Cash J, Reuben R, Crichton ML. The biomechanics of wounds at physiologically relevant levels: Understanding skin's stress-shielding effect for the quantitative assessment of healing. Mater Today Bio 2024; 25:100963. [PMID: 38312802 PMCID: PMC10835282 DOI: 10.1016/j.mtbio.2024.100963] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/10/2023] [Revised: 12/15/2023] [Accepted: 01/15/2024] [Indexed: 02/06/2024] Open
Abstract
Wounds are responsible for the decrease in quality of life of billions of people around the world. Their assessment relies on subjective parameters which often delays optimal treatments and results in increased healthcare costs. In this work, we sought to understand and quantify how wounds at different healing stages (days 1, 3, 7 and 14 post wounding) change the mechanical properties of the tissues that contain them, and how these could be measured at clinically relevant strain levels, as a step towards quantitative wound tracking technologies. To achieve this, we used digital image correlation and mechanical testing on a mouse model of wound healing to map the global and local tissue strains. We found no significant differences in the elastic and viscoelastic properties of wounded vs unwounded skin when samples were measured in bulk, presumably as these were masked by the protective mechanisms of skin, which redistributes the applied loads to mitigate high stresses and reduce tissue damage. By measuring local strain values and observing the distinct patterns they formed, it was possible to establish a connection between the healing phase of the tissue (determined by the time post-injury and the observed histological features) and the overall mechanical behaviour. Importantly, these parameters were measured from the surface of the tissue, using physiologically relevant strains without increasing the tissue's damage. Adaptations of these approaches for clinical use have the potential to aid in the identification of skin healing problems, such as excessive inflammation or lack of mechanical progression over time. An increase, decrease, or lack of change in the elasticity and viscoelasticity parameters, can be indicative of wound state, thus ultimately leading to improved diagnostic outcomes.
Collapse
Affiliation(s)
- Sara Medina-Lombardero
- School of Engineering and Physical Sciences, Heriot-Watt University, Edinburgh, EH14 4AS, United Kingdom
| | - Connor Bain
- School of Engineering and Physical Sciences, Heriot-Watt University, Edinburgh, EH14 4AS, United Kingdom
| | - Laura Charlton
- School of Engineering, University of Edinburgh, Edinburgh, EH9 3RF, United Kingdom
| | - Antonella Pellicoro
- Centre for Inflammation Research, University of Edinburgh, Edinburgh, EH16 4TJ, United Kingdom
| | - Holly Rocliffe
- Centre for Inflammation Research, University of Edinburgh, Edinburgh, EH16 4TJ, United Kingdom
| | - Jenna Cash
- Centre for Inflammation Research, University of Edinburgh, Edinburgh, EH16 4TJ, United Kingdom
| | - Robert Reuben
- School of Engineering and Physical Sciences, Heriot-Watt University, Edinburgh, EH14 4AS, United Kingdom
| | - Michael L. Crichton
- School of Engineering and Physical Sciences, Heriot-Watt University, Edinburgh, EH14 4AS, United Kingdom
| |
Collapse
|
33
|
Gao F, Yang X, Song W. Bioinspired Supramolecular Hydrogel from Design to Applications. SMALL METHODS 2024; 8:e2300753. [PMID: 37599261 DOI: 10.1002/smtd.202300753] [Citation(s) in RCA: 10] [Impact Index Per Article: 10.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 06/15/2023] [Indexed: 08/22/2023]
Abstract
Nature offers a wealth of opportunities to solve scientific and technological issues based on its unique structures and function. The dynamic non-covalent interaction is considered to be the main base of living functions of creatures including humans, animals, and plants. Supramolecular hydrogels formed by non-covalent bonding interactions has become a unique platform for constructing promising materials for medicine, energy, electronic, and biological substitute. In this review, the self-assemble principle of supramolecular hydrogels is summarized. Next, the stimulation of external environment that triggers the assembly or disassembly of supramolecular hydrogels are recapitulated, including temperature, mechanics, light, pH, ions, etc. The main applications of bioinspired supramolecular hydrogels in terms of bionic objects including humans, animals, and plants are also described. Although so many efforts are done for revealing the synergized mechanism of the function and non-covalent interactions on the supramolecular hydrogel, the complexity and variability between stimulus and non-covalent bonding in the supramolecular system still require impeccable theories. As an outlook, the bioinspired supramolecular hydrogel is just beginning to exhibit its great potential in human life, offering significant opportunities in drug delivery and screening, implantable devices and substitutions, tissue engineering, micro-fluidic devices, and biosensors.
Collapse
Affiliation(s)
- Feng Gao
- State Key Laboratory of Supramolecular Structure and Materials, College of Chemistry, Jilin University, Changchun, 130012, P. R. China
| | - Xuhao Yang
- State Key Laboratory of Supramolecular Structure and Materials, College of Chemistry, Jilin University, Changchun, 130012, P. R. China
| | - Wenlong Song
- State Key Laboratory of Supramolecular Structure and Materials, College of Chemistry, Jilin University, Changchun, 130012, P. R. China
| |
Collapse
|
34
|
Xiao JH, Zhang ZB, Li J, Chen SM, Gao HL, Liao Y, Chen L, Wang Z, Lu Y, Hou Y, Wu H, Zou D, Yu SH. Bioinspired polysaccharide-based nanocomposite membranes with robust wet mechanical properties for guided bone regeneration. Natl Sci Rev 2024; 11:nwad333. [PMID: 38333231 PMCID: PMC10852990 DOI: 10.1093/nsr/nwad333] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/03/2023] [Revised: 11/27/2023] [Accepted: 12/12/2023] [Indexed: 02/10/2024] Open
Abstract
Polysaccharide-based membranes with excellent mechanical properties are highly desired. However, severe mechanical deterioration under wet conditions limits their biomedical applications. Here, inspired by the structural heterogeneity of strong yet hydrated biological materials, we propose a strategy based on heterogeneous crosslink-and-hydration (HCH) of a molecule/nano dual-scale network to fabricate polysaccharide-based nanocomposites with robust wet mechanical properties. The heterogeneity lies in that the crosslink-and-hydration occurs in the molecule-network while the stress-bearing nanofiber-network remains unaffected. As one demonstration, a membrane assembled by bacterial cellulose nanofiber-network and Ca2+-crosslinked and hydrated sodium alginate molecule-network is designed. Studies show that the crosslinked-and-hydrated molecule-network restricts water invasion and boosts stress transfer of the nanofiber-network by serving as interfibrous bridge. Overall, the molecule-network makes the membrane hydrated and flexible; the nanofiber-network as stress-bearing component provides strength and toughness. The HCH dual-scale network featuring a cooperative effect stimulates the design of advanced biomaterials applied under wet conditions such as guided bone regeneration membranes.
Collapse
Affiliation(s)
- Jian-Hong Xiao
- Department of Chemistry, New Cornerstone Science Laboratory, Institute of Biomimetic Materials & Chemistry, Anhui Engineering Laboratory of Biomimetic Materials, Division of Nanomaterials & Chemistry, Hefei National Research Center for Physical Sciences at the Microscale, University of Science and Technology of China, Hefei 230026, China
- Department of Dental Implant Center, Stomatologic Hospital and College, Key Laboratory of Oral Diseases Research of Anhui Province, Anhui Medical University, Hefei 230032, China
| | - Zhen-Bang Zhang
- Department of Chemistry, New Cornerstone Science Laboratory, Institute of Biomimetic Materials & Chemistry, Anhui Engineering Laboratory of Biomimetic Materials, Division of Nanomaterials & Chemistry, Hefei National Research Center for Physical Sciences at the Microscale, University of Science and Technology of China, Hefei 230026, China
| | - JiaHao Li
- CAS Key Laboratory of Mechanical Behavior and Design of Materials, Department of Modern Mechanics, CAS Center for Excellence in Complex System Mechanics, University of Science and Technology of China, Hefei 230027, China
| | - Si-Ming Chen
- Department of Chemistry, New Cornerstone Science Laboratory, Institute of Biomimetic Materials & Chemistry, Anhui Engineering Laboratory of Biomimetic Materials, Division of Nanomaterials & Chemistry, Hefei National Research Center for Physical Sciences at the Microscale, University of Science and Technology of China, Hefei 230026, China
| | - Huai-Ling Gao
- Department of Chemistry, New Cornerstone Science Laboratory, Institute of Biomimetic Materials & Chemistry, Anhui Engineering Laboratory of Biomimetic Materials, Division of Nanomaterials & Chemistry, Hefei National Research Center for Physical Sciences at the Microscale, University of Science and Technology of China, Hefei 230026, China
- CAS Key Laboratory of Mechanical Behavior and Design of Materials, Department of Modern Mechanics, CAS Center for Excellence in Complex System Mechanics, University of Science and Technology of China, Hefei 230027, China
| | - YinXiu Liao
- Department of Oral Surgery, College of Stomatology, National Clinical Research Center for Oral Diseases, Shanghai Key Laboratory of Stomatology, Shanghai Research Institute of Stomatology, Shanghai Ninth People's Hospital Affiliated to Shanghai Jiao Tong University School of Medicine, Shanghai 200001, China
| | - Lu Chen
- Department of Oral Surgery, College of Stomatology, National Clinical Research Center for Oral Diseases, Shanghai Key Laboratory of Stomatology, Shanghai Research Institute of Stomatology, Shanghai Ninth People's Hospital Affiliated to Shanghai Jiao Tong University School of Medicine, Shanghai 200001, China
| | - ZiShuo Wang
- Department of Oral Surgery, College of Stomatology, National Clinical Research Center for Oral Diseases, Shanghai Key Laboratory of Stomatology, Shanghai Research Institute of Stomatology, Shanghai Ninth People's Hospital Affiliated to Shanghai Jiao Tong University School of Medicine, Shanghai 200001, China
| | - YiFan Lu
- Department of Dental Implant Center, Stomatologic Hospital and College, Key Laboratory of Oral Diseases Research of Anhui Province, Anhui Medical University, Hefei 230032, China
| | - YuanZhen Hou
- CAS Key Laboratory of Mechanical Behavior and Design of Materials, Department of Modern Mechanics, CAS Center for Excellence in Complex System Mechanics, University of Science and Technology of China, Hefei 230027, China
| | - HengAn Wu
- CAS Key Laboratory of Mechanical Behavior and Design of Materials, Department of Modern Mechanics, CAS Center for Excellence in Complex System Mechanics, University of Science and Technology of China, Hefei 230027, China
| | - DuoHong Zou
- Department of Dental Implant Center, Stomatologic Hospital and College, Key Laboratory of Oral Diseases Research of Anhui Province, Anhui Medical University, Hefei 230032, China
- Department of Oral Surgery, College of Stomatology, National Clinical Research Center for Oral Diseases, Shanghai Key Laboratory of Stomatology, Shanghai Research Institute of Stomatology, Shanghai Ninth People's Hospital Affiliated to Shanghai Jiao Tong University School of Medicine, Shanghai 200001, China
| | - Shu-Hong Yu
- Department of Chemistry, New Cornerstone Science Laboratory, Institute of Biomimetic Materials & Chemistry, Anhui Engineering Laboratory of Biomimetic Materials, Division of Nanomaterials & Chemistry, Hefei National Research Center for Physical Sciences at the Microscale, University of Science and Technology of China, Hefei 230026, China
- Institute of Innovative Materials (I2M), Department of Chemistry, Department of Materials Science and Engineering, Southern University of Science and Technology, Shenzhen 518055, China
| |
Collapse
|
35
|
Crossley RM, Johnson S, Tsingos E, Bell Z, Berardi M, Botticelli M, Braat QJS, Metzcar J, Ruscone M, Yin Y, Shuttleworth R. Modeling the extracellular matrix in cell migration and morphogenesis: a guide for the curious biologist. Front Cell Dev Biol 2024; 12:1354132. [PMID: 38495620 PMCID: PMC10940354 DOI: 10.3389/fcell.2024.1354132] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/11/2023] [Accepted: 02/12/2024] [Indexed: 03/19/2024] Open
Abstract
The extracellular matrix (ECM) is a highly complex structure through which biochemical and mechanical signals are transmitted. In processes of cell migration, the ECM also acts as a scaffold, providing structural support to cells as well as points of potential attachment. Although the ECM is a well-studied structure, its role in many biological processes remains difficult to investigate comprehensively due to its complexity and structural variation within an organism. In tandem with experiments, mathematical models are helpful in refining and testing hypotheses, generating predictions, and exploring conditions outside the scope of experiments. Such models can be combined and calibrated with in vivo and in vitro data to identify critical cell-ECM interactions that drive developmental and homeostatic processes, or the progression of diseases. In this review, we focus on mathematical and computational models of the ECM in processes such as cell migration including cancer metastasis, and in tissue structure and morphogenesis. By highlighting the predictive power of these models, we aim to help bridge the gap between experimental and computational approaches to studying the ECM and to provide guidance on selecting an appropriate model framework to complement corresponding experimental studies.
Collapse
Affiliation(s)
- Rebecca M. Crossley
- Wolfson Centre for Mathematical Biology, Mathematical Institute, University of Oxford, Oxford, United Kingdom
| | - Samuel Johnson
- Wolfson Centre for Mathematical Biology, Mathematical Institute, University of Oxford, Oxford, United Kingdom
| | - Erika Tsingos
- Computational Developmental Biology Group, Institute of Biodynamics and Biocomplexity, Utrecht University, Utrecht, Netherlands
| | - Zoe Bell
- Northern Institute for Cancer Research, Newcastle University, Newcastle upon Tyne, United Kingdom
| | - Massimiliano Berardi
- LaserLab, Department of Physics and Astronomy, Vrije Universiteit Amsterdam, Amsterdam, Netherlands
- Optics11 life, Amsterdam, Netherlands
| | | | - Quirine J. S. Braat
- Department of Applied Physics and Science Education, Eindhoven University of Technology, Eindhoven, Netherlands
| | - John Metzcar
- Department of Intelligent Systems Engineering, Indiana University, Bloomington, IN, United States
- Department of Informatics, Indiana University, Bloomington, IN, United States
| | | | - Yuan Yin
- Wolfson Centre for Mathematical Biology, Mathematical Institute, University of Oxford, Oxford, United Kingdom
| | | |
Collapse
|
36
|
Tjust AE, Hellman U, Giannopoulos A, Winsnes A, Strigård K, Gunnarsson U. Evaluation of Extracellular Matrix Remodeling in Full-thickness Skin Grafts in Mice. J Histochem Cytochem 2024; 72:79-94. [PMID: 38264898 PMCID: PMC10851880 DOI: 10.1369/00221554231225995] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/04/2023] [Accepted: 12/19/2023] [Indexed: 01/25/2024] Open
Abstract
Abdominal hernia is a protruding weakness in the abdominal wall. It affects abdominal strength and life quality and can lead to complications due to intestinal entrapment. Autologous full-thickness skin graft (FTSG) has recently become an alternative material for reinforcement in the surgical repair of large abdominal hernias instead of synthetic mesh. FTSG eventually integrates with the abdominal wall, but the long-term fate of the graft itself is not fully understood. This has implications as to how these grafts should be optimally used and handled intraoperatively. This study investigates the remodeling of FTSG in either the onlay or the intraperitoneal position 8 weeks after FTSG transplantation in an experimental mouse model. There was a significant presence of fibroblasts, indicated by vimentin and S100A4 staining, but there were significant variations among animals as to how much of the graft had been remodeled into dense connective tissue. This correlated significantly with the proportion of vimentin-positive cells in the dense connective tissue. We also found that collagen hybridizing peptide staining intensity, a marker of active remodeling, was significantly associated with the proportion of S100A4-positive cells in the dense connective tissue of the FTSG.
Collapse
Affiliation(s)
- Anton Erik Tjust
- Department of Medical Sciences, Clinical Neurophysiology, Uppsala University, Uppsala, Sweden, Umeå University, Umeå, Sweden
- Department of Clinical Sciences, Umeå University, Umeå, Sweden
| | - Urban Hellman
- Department of Public Health and Clinical Medicine, Umeå University, Umeå, Sweden
| | - Antonios Giannopoulos
- Surgery, Department of Surgical and Perioperative Sciences, Umeå University, Umeå, Sweden
| | - Annika Winsnes
- Surgery, Department of Surgical and Perioperative Sciences, Umeå University, Umeå, Sweden
| | - Karin Strigård
- Surgery, Department of Surgical and Perioperative Sciences, Umeå University, Umeå, Sweden
| | - Ulf Gunnarsson
- Surgery, Department of Surgical and Perioperative Sciences, Umeå University, Umeå, Sweden
| |
Collapse
|
37
|
Lee PY, Fryc G, Gnalian J, Wang B, Hua Y, Waxman S, Zhong F, Yang B, Sigal IA. Direct measurements of collagen fiber recruitment in the posterior pole of the eye. Acta Biomater 2024; 173:135-147. [PMID: 37967694 PMCID: PMC10843755 DOI: 10.1016/j.actbio.2023.11.013] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/15/2023] [Revised: 11/07/2023] [Accepted: 11/09/2023] [Indexed: 11/17/2023]
Abstract
Collagen is the main load-bearing component of the peripapillary sclera (PPS) and lamina cribrosa (LC) in the eye. Whilst it has been shown that uncrimping and recruitment of the PPS and LC collagen fibers underlies the macro-scale nonlinear stiffening of both tissues with increased intraocular pressure (IOP), the uncrimping and recruitment as a function of local stretch have not been directly measured. This knowledge is crucial to understanding their functions in bearing loads and maintaining tissue integrity. In this project we measured local stretch-induced collagen fiber bundle uncrimping and recruitment curves of the PPS and LC. Thin coronal samples of PPS and LC of sheep eyes were mounted and stretched biaxially quasi-statically using a custom system. At each step, we imaged the PPS and LC with instant polarized light microscopy and quantified pixel-level (1.5 μm/pixel) collagen fiber orientations. We used digital image correlation to measure the local stretch and quantified collagen crimp by the circular standard deviation of fiber orientations, or waviness. Local stretch-recruitment curves of PPS and LC approximated sigmoid functions. PPS recruited more fibers than the LC at the low levels of stretch. At 10% stretch the curves crossed with 75% bundles recruited. The PPS had higher uncrimping rate and waviness remaining after recruitment than the LC: 0.9º vs. 0.6º and 3.1º vs. 2.7º. Altogether our findings support describing fiber recruitment of both PPS and LC with sigmoid curves, with the PPS recruiting faster and at lower stretch than the LC, consistent with a stiffer tissue. STATEMENT OF SIGNIFICANCE: Peripapillary sclera (PPS) and lamina cribrosa (LC) collagen recruitment behaviors are central to the nonlinear mechanical behavior of the posterior pole of the eye. How PPS and LC collagen fibers recruit under stretch is crucial to develop constitutive models of the tissues but remains unclear. We used image-based stretch testing to characterize PPS and LC collagen fiber bundle recruitment under local stretch. We found that fiber-level stretch-recruitment curves of PPS and LC approximated sigmoid functions. PPS recruited more fibers at a low stretch, but at 10% bundle stretch the two curves crossed with 75% bundles recruited. We also found that PPS and LC fibers had different uncrimping rates and non-zero waviness's when recruited.
Collapse
Affiliation(s)
- Po-Yi Lee
- Department of Ophthalmology, University of Pittsburgh School of Medicine, University of Pittsburgh, Pittsburgh, PA, USA; Department of Bioengineering, Swanson School of Engineering, University of Pittsburgh, Pittsburgh, PA, USA
| | - Gosia Fryc
- Department of Chemistry, Dietrich School of Arts and Sciences, University of Pittsburgh, Pittsburgh, PA, USA
| | - John Gnalian
- Department of Ophthalmology, University of Pittsburgh School of Medicine, University of Pittsburgh, Pittsburgh, PA, USA
| | - Bingrui Wang
- Department of Ophthalmology, University of Pittsburgh School of Medicine, University of Pittsburgh, Pittsburgh, PA, USA
| | - Yi Hua
- Department of Ophthalmology, University of Pittsburgh School of Medicine, University of Pittsburgh, Pittsburgh, PA, USA; Department of Biomedical Engineering, University of Mississippi, University, MS, USA; Department of Mechanical Engineering, University of Mississippi, University, MS, USA
| | - Susannah Waxman
- Department of Ophthalmology, University of Pittsburgh School of Medicine, University of Pittsburgh, Pittsburgh, PA, USA
| | - Fuqiang Zhong
- Department of Ophthalmology, University of Pittsburgh School of Medicine, University of Pittsburgh, Pittsburgh, PA, USA
| | - Bin Yang
- Department of Engineering, Rangos School of Health Sciences, Duquesne University, Pittsburgh, PA, USA
| | - Ian A Sigal
- Department of Ophthalmology, University of Pittsburgh School of Medicine, University of Pittsburgh, Pittsburgh, PA, USA; Department of Bioengineering, Swanson School of Engineering, University of Pittsburgh, Pittsburgh, PA, USA.
| |
Collapse
|
38
|
Menke MA, Li BM, Arnold MG, Mueller LE, Dietrich R, Zhou S, Kelley‐Loughnane N, Dennis P, Boock JT, Estevez J, Tabor CE, Sparks JL. Silky Liquid Metal Electrodes for On-Skin Health Monitoring. Adv Healthc Mater 2024; 13:e2301811. [PMID: 37779336 PMCID: PMC11468510 DOI: 10.1002/adhm.202301811] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/07/2023] [Revised: 09/15/2023] [Indexed: 10/03/2023]
Abstract
Next generation on-skin electrodes will require soft, flexible, and gentle materials to provide both high-fidelity sensing and wearer comfort. However, many commercially available on-skin electrodes lack these key properties due to their use of rigid hardware, harsh adhesives, uncomfortable support structures, and poor breathability. To address these challenges, this work presents a new device paradigm by joining biocompatible electrospun spider silk with printable liquid metal to yield an incredibly soft and scalable on-skin electrode that is strain-tolerant, conformable, and gentle on-skin. These electrodes, termed silky liquid metal (SLiM) electrodes, are found to be over five times more breathable than commercial wet electrodes, while the silk's intrinsic adhesion mechanism allows SLiM electrodes to avoid the use of harsh artificial adhesives, potentially decreasing skin irritation and inflammation over long-term use. Finally, the SLiM electrodes provide comparable impedances to traditional wet and other liquid metal electrodes, offering a high-fidelity sensing alternative with increased wearer comfort. Human subject testing confirmed the SLiM electrodes ability to sense electrophysiological signals with high fidelity and minimal irritation to the skin. The unique properties of the reported SLiM electrodes offer a comfortable electrophysiological sensing solution especially for patients with pre-existing skin conditions or surface wounds.
Collapse
Affiliation(s)
- Maria A. Menke
- Department of ChemicalPaper, and Biomedical EngineeringMiami UniversityOxfordOH45056USA
- Air Force Research LaboratoryMaterials and Manufacturing DirectorateWright‐Patterson AFBDaytonOH45433USA
| | - Braden M. Li
- Air Force Research LaboratoryMaterials and Manufacturing DirectorateWright‐Patterson AFBDaytonOH45433USA
- Air Force Life Cycle Management CenterHuman Systems DivisionWright‐Patterson AFBDaytonOH45433USA
| | - Meghan G. Arnold
- Department of ChemicalPaper, and Biomedical EngineeringMiami UniversityOxfordOH45056USA
| | - Logan E. Mueller
- Department of ChemicalPaper, and Biomedical EngineeringMiami UniversityOxfordOH45056USA
| | - Robin Dietrich
- Air Force Research LaboratoryMaterials and Manufacturing DirectorateWright‐Patterson AFBDaytonOH45433USA
| | - Shijie Zhou
- Department of ChemicalPaper, and Biomedical EngineeringMiami UniversityOxfordOH45056USA
| | - Nancy Kelley‐Loughnane
- Air Force Research LaboratoryMaterials and Manufacturing DirectorateWright‐Patterson AFBDaytonOH45433USA
| | - Patrick Dennis
- Air Force Research LaboratoryMaterials and Manufacturing DirectorateWright‐Patterson AFBDaytonOH45433USA
| | - Jason T. Boock
- Department of ChemicalPaper, and Biomedical EngineeringMiami UniversityOxfordOH45056USA
| | - Joseph Estevez
- Naval Air Warfare CenterWeapons DivisionChina LakeCA93555USA
| | - Christopher E. Tabor
- Air Force Research LaboratoryMaterials and Manufacturing DirectorateWright‐Patterson AFBDaytonOH45433USA
| | - Jessica L. Sparks
- Department of ChemicalPaper, and Biomedical EngineeringMiami UniversityOxfordOH45056USA
| |
Collapse
|
39
|
Bidhendi AJ, Lampron O, Gosselin FP, Geitmann A. Cell geometry regulates tissue fracture. Nat Commun 2023; 14:8275. [PMID: 38092784 PMCID: PMC10719271 DOI: 10.1038/s41467-023-44075-4] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/21/2023] [Accepted: 11/29/2023] [Indexed: 12/17/2023] Open
Abstract
In vascular plants, the epidermal surfaces of leaves and flower petals often display cells with wavy geometries forming intricate jigsaw puzzle patterns. The prevalence and diversity of these complex epidermal patterns, originating from simple polyhedral progenitor cells, suggest adaptive significance. However, despite multiple efforts to explain the evolutionary drivers behind these geometrical features, compelling validation remains elusive. Employing a multidisciplinary approach that integrates microscopic and macroscopic fracture experiments with computational fracture mechanics, we demonstrate that wavy epidermal cells toughen the plants' protective skin. Through a multi-scale framework, we demonstrate that this energy-efficient patterning mechanism is universally applicable for toughening biological and synthetic materials. Our findings reveal a tunable structural-mechanical strategy employed in the microscale design of plants to protect them from deleterious surface fissures while facilitating and strategically directing beneficial ones. These findings hold implications for targeted plant breeding aimed at enhancing resilience in fluctuating environmental conditions. From an engineering perspective, our work highlights the sophisticated design principles the plant kingdom offers to inspire metamaterials.
Collapse
Affiliation(s)
- Amir J Bidhendi
- Department of Plant Science, McGill University, Macdonald Campus, 21111 Lakeshore, Ste-Anne-de-Bellevue, Québec, H9X 3V9, Canada.
- EERS Global Technologies, Montreal, Canada.
| | - Olivier Lampron
- Laboratoire de Mécanique Multi-échelles, Département de génie mécanique, École Polytechnique de Montréal, Montreal, Québec, H3C 3A7, Canada
| | - Frédérick P Gosselin
- Laboratoire de Mécanique Multi-échelles, Département de génie mécanique, École Polytechnique de Montréal, Montreal, Québec, H3C 3A7, Canada
| | - Anja Geitmann
- Department of Plant Science, McGill University, Macdonald Campus, 21111 Lakeshore, Ste-Anne-de-Bellevue, Québec, H9X 3V9, Canada.
| |
Collapse
|
40
|
Piazza F, Sacco P, Marsich E, Baj G, Brun F, Asaro F, Grassi G, Grassi M, Donati I. Cell Activities on Viscoelastic Substrates Show an Elastic Energy Threshold and Correlate with the Linear Elastic Energy Loss in the Strain‐Softening Region. ADVANCED FUNCTIONAL MATERIALS 2023; 33. [DOI: 10.1002/adfm.202307224] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 06/26/2023] [Indexed: 02/06/2025]
Abstract
Energy‐sensing in viscoelastic substrates has recently been shown to be an important regulator of cellular activities, modulating mechanical transmission and transduction processes. Here, this study fine‐tunes the elastic energy of viscoelastic hydrogels with different physical and chemical compositions and shows that this has an impact on cell response in 2D cell cultures. This study shows that there is a threshold value for elastic energy (≈0.15 J m−3) above which cell adhesion is impaired. When hydrogels leave the linear stress–strain range, they show softening (plastic) behavior typical of soft tissues. This study identifies a correlation between the theoretical linear elastic energy loss in the strain‐softening region and the number of cells adhering to the substrate. This also has implications for the formation of vinculin‐rich anchorage points and the ability of cells to remodel the substrate through traction forces. Overall, the results reported in this study support that the relationship between cell activities and energy‐sensing in viscoelastic substrates is an important aspect to consider in the development of reliable ex vivo models of human tissues that mimic both normal and pathological conditions.
Collapse
Affiliation(s)
- Francesco Piazza
- Department of Life Sciences University of Trieste Via Licio Giorgieri 5 I‐34127 Trieste Italy
| | - Pasquale Sacco
- Department of Life Sciences University of Trieste Via Licio Giorgieri 5 I‐34127 Trieste Italy
| | - Eleonora Marsich
- Department of Medicine Surgery and Health Sciences University of Trieste Piazza dell'Ospitale 1 I‐34129 Trieste Italy
| | - Gabriele Baj
- Department of Life Sciences University of Trieste Via Licio Giorgieri 5 I‐34127 Trieste Italy
| | - Francesco Brun
- Department of Engineering and Architecture University of Trieste Via A. Valerio 6/1 I‐34127 Trieste Italy
| | - Fioretta Asaro
- Department of Chemical and Pharmaceutical Sciences University of Trieste Via Licio Giorgieri 1 I‐34127 Trieste Italy
| | - Gabriele Grassi
- Department of Life Sciences University of Trieste Via Licio Giorgieri 5 I‐34127 Trieste Italy
| | - Mario Grassi
- Department of Engineering and Architecture University of Trieste Via A. Valerio 6/1 I‐34127 Trieste Italy
| | - Ivan Donati
- Department of Life Sciences University of Trieste Via Licio Giorgieri 5 I‐34127 Trieste Italy
| |
Collapse
|
41
|
Rosenberg JL, Schaible E, Bostrom A, Lazar AA, Graham JL, Stanhope KL, Ritchie RO, Alliston TN, Lotz JC, Havel PJ, Acevedo C, Fields AJ. Type 2 diabetes impairs annulus fibrosus fiber deformation and rotation under disc compression in the University of California Davis type 2 diabetes mellitus (UCD-T2DM) rat model. PNAS NEXUS 2023; 2:pgad363. [PMID: 38094616 PMCID: PMC10718642 DOI: 10.1093/pnasnexus/pgad363] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 05/03/2023] [Accepted: 10/17/2023] [Indexed: 12/17/2023]
Abstract
Understanding the biomechanical behavior of the intervertebral disc is crucial for studying disease mechanisms and developing tissue engineering strategies for managing disc degeneration. We used synchrotron small-angle X-ray scattering to investigate how changes to collagen behavior contribute to alterations in the disc's ability to resist compression. Coccygeal motion segments from 6-month-old lean Sprague-Dawley rats ( n = 7 ) and diabetic obese University of California Davis type 2 diabetes mellitus (UCD-T2DM) rats ( n = 6 , diabetic for 68 ± 7 days) were compressed during simultaneous synchrotron scanning to measure collagen strain at the nanoscale (beamline 7.3.3 of the Advanced Light Source). After compression, the annulus fibrosus was assayed for nonenzymatic cross-links. In discs from lean rats, resistance to compression involved two main energy-dissipation mechanisms at the nanoscale: (1) rotation of the two groups of collagen fibrils forming the annulus fibrosus and (2) straightening (uncrimping) and stretching of the collagen fibrils. In discs from diabetic rats, both mechanisms were significantly impaired. Specifically, diabetes reduced fibril rotation by 31% and reduced collagen fibril strain by 30% (compared to lean discs). The stiffening of collagen fibrils in the discs from diabetic rats was consistent with a 31% higher concentration of nonenzymatic cross-links and with evidence of earlier onset plastic deformations such as fibril sliding and fibril-matrix delamination. These findings suggest that fibril reorientation, stretching, and straightening are key deformation mechanisms that facilitate whole-disc compression, and that type 2 diabetes impairs these efficient and low-energy elastic deformation mechanisms, thereby altering whole-disc behavior and inducing the earlier onset of plastic deformation.
Collapse
Affiliation(s)
- James L Rosenberg
- Departments of Mechanical and Biomedical Engineering, University of Utah, Salt Lake City, UT 84112, USA
| | - Eric Schaible
- Advanced Light Source, Lawrence Berkeley Laboratory, Berkeley, CA 94720, USA
| | - Alan Bostrom
- Department of Epidemiology and Biostatistics, University of California, San Francisco, CA 94143, USA
| | - Ann A Lazar
- Department of Epidemiology and Biostatistics, University of California, San Francisco, CA 94143, USA
| | - James L Graham
- Department of Molecular Biosciences, University of California, Davis, CA 95616, USA
- Department of Nutrition, University of California, Davis, CA 95616, USA
| | - Kimber L Stanhope
- Department of Molecular Biosciences, University of California, Davis, CA 95616, USA
- Department of Nutrition, University of California, Davis, CA 95616, USA
| | - Robert O Ritchie
- Materials Science Division, Lawrence Berkeley National Laboratory, Berkeley, CA 94720, USA
- Department of Materials Science and Engineering, University of California, Berkeley, CA 94720, USA
| | - Tamara N Alliston
- Department of Orthopaedic Surgery, University of California, San Francisco, CA 94143, USA
| | - Jeffrey C Lotz
- Department of Orthopaedic Surgery, University of California, San Francisco, CA 94143, USA
| | - Peter J Havel
- Department of Molecular Biosciences, University of California, Davis, CA 95616, USA
- Department of Nutrition, University of California, Davis, CA 95616, USA
| | - Claire Acevedo
- Departments of Mechanical and Biomedical Engineering, University of Utah, Salt Lake City, UT 84112, USA
- Department of Mechanical and Aerospace Engineering, University of California, San Diego, CA 92093, USA
| | - Aaron J Fields
- Department of Orthopaedic Surgery, University of California, San Francisco, CA 94143, USA
| |
Collapse
|
42
|
Ross CJ, Miyake BA, Marsh HR, Bryant PR, Lee CH, Barreiro GC. The Lasso Suture: Ex Vivo Testing of an Alternative to the High-Tension Deep Dermal Stitch. Plast Reconstr Surg 2023; 152:862e-866e. [PMID: 36912934 DOI: 10.1097/prs.0000000000010391] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 03/14/2023]
Abstract
SUMMARY Wound dehiscence, with an estimated occurrence rate greater than 4% in plastic surgery, is generally underreported, and can be an indicator of increased mortality and remission rates. The authors developed the lasso suture as a stronger alternative to the current standard patterns. The lasso suture takes less time to perform than the standard high-tension wound repair method. The authors dissected caprine skin specimens to create full-thickness wounds for suture repair using simple interrupted, vertical mattress, horizontal mattress, and deep dermal with running intradermal (DDR) sutures ( n = 10) and lasso sutures ( n = 9). They then conducted uniaxial failure testing to quantify the suture rupture stresses and strains. They also measured the suture operating time with medical students and residents (PGY or MS programs) performing wound repair (10-cm wide, 2-cm deep, 2-0 polydioxanone sutures) on soft-fixed human cadaver skin. The lasso stitch had a greater first-suture rupture stress compared with all other patterns ( P < 0.001): 2.46 ± 0.27 MPa for lasso versus 0.69 ± 0.14 MPa for simple interrupted, 0.68 ± 0.13 MPa for vertical mattress, 0.50 ± 0.10 MPa for horizontal mattress, and 1.17 ± 0.28 MPa for DDR sutures. Performing the lasso suture was 28% faster than performing standard DDR (264 ± 21 versus 349 ± 25 seconds; P = 0.027). In summary, the authors showed that the lasso has superior mechanical properties compared with the studied traditional sutures, and that the new technique can be performed more quickly than the current standard (DDR stitch) for high-tension wounds. Future animal and in-clinic studies will be helpful to confirm the authors' findings in this proof-of-concept study. CLINICAL RELEVANCE STATEMENT The authors propose the lasso suture, a new suturing method with improved tensile performance compared with traditional techniques and a faster operative time than the deep dermal stitch typically used for high-tension wounds in reconstructive surgery to prevent wound dehiscence.
Collapse
Affiliation(s)
- Colton J Ross
- From the School of Aerospace and Mechanical Engineering
| | - Bradley A Miyake
- Plastic and Reconstructive Surgery, Department of Surgery, University of Oklahoma Health Sciences Center
| | - Henry R Marsh
- Plastic and Reconstructive Surgery, Department of Surgery, University of Oklahoma Health Sciences Center
| | - Parker R Bryant
- Institute for Biomedical Engineering, Science and Technology, University of Oklahoma
| | - Chung-Hao Lee
- From the School of Aerospace and Mechanical Engineering
- Institute for Biomedical Engineering, Science and Technology, University of Oklahoma
| | - Guilherme C Barreiro
- Plastic and Reconstructive Surgery, Department of Surgery, University of Oklahoma Health Sciences Center
- Plastic and Reconstructive Surgery, State University of Campinas-UNICAMP
- Plastic, Reconstructive, and Burn Surgery, State Institute for the Public Server's Health-IAMSPE
| |
Collapse
|
43
|
Lee J, Bark H, Xue Y, Lee PS, Zhong M. Size-Selective Ionic Crosslinking Provides Stretchable Mixed Ionic-Electronic Conductors. Angew Chem Int Ed Engl 2023; 62:e202306994. [PMID: 37597178 DOI: 10.1002/anie.202306994] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/18/2023] [Revised: 07/08/2023] [Accepted: 08/16/2023] [Indexed: 08/21/2023]
Abstract
Mechanically compliant conductors are of utmost importance for the emerging fields of soft electronics and robotics. However, the development of intrinsically deformable organic conductors remains a challenge due to the trade-off between mechanical performance and charge mobility. In this study, we report a solution to this issue based on size-selective ionic crosslinking. This rationally designed crosslinking mediated by length-regulated oligo(ethylene glycol) pendant groups and metal ions simultaneously improved the softness and toughness and ensured excellent mixed ionic-electronic conductivity in poly(3,4-ethylenedioxythiophene):polystyrene sulfonate composite materials. Moreover, the added ions remarkably promoted accumulation of charge carriers in response to temperature gradient, thus offering a viable approach to stretchable thermoelectric generators with enhanced stability against humidity.
Collapse
Affiliation(s)
- Junwoo Lee
- Department of Chemical and Environmental Engineering, Yale University, New Haven, CT 06520, USA
| | - Hyunwoo Bark
- School of Materials Science and Engineering, Nanyang Technological University, 50 Nanyang Avenue, Singapore, 639798, Singapore
| | - Yazhen Xue
- Department of Chemical and Environmental Engineering, Yale University, New Haven, CT 06520, USA
| | - Pooi See Lee
- School of Materials Science and Engineering, Nanyang Technological University, 50 Nanyang Avenue, Singapore, 639798, Singapore
| | - Mingjiang Zhong
- Department of Chemical and Environmental Engineering, Yale University, New Haven, CT 06520, USA
- Department of Chemistry, Yale University, New Haven, CT 06520, USA
| |
Collapse
|
44
|
Abraham JD, Vaissière A, Desouches C, Thiery G, Bertrand B, Alfandari B, Courtois I, Azencot A, Casoli V, Haen P, Colson T, Hornebeck W, Ritter D. Clinical validation of an elastin-derived trifunctional peptide for skin regeneration. Am J Transl Res 2023; 15:4620-4628. [PMID: 37560234 PMCID: PMC10408523] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/15/2023] [Accepted: 06/29/2023] [Indexed: 08/11/2023]
Abstract
UNLABELLED Aging is associated with progressive skin fragility, characterized in part by extracellular matrix (ECM) fragmentation. This degradation produces matrikines which have an impact on ECM rremodeling. Our group previously designed and characterized a trifunctional peptide (TFP), constituted of i) an elastokine motif (VGVAPG)3, able to increase the expression of matrix constituent through the stimulation of the elastin-binding protein receptor, ii) a tripeptide inhibiting matrix metalloproteinase-1 activity (GIL), and iii) a linker domain acting as a competitive substrate for urokinase (RVRL). TFP was shown to activate the production of matrix constituents while inhibiting Matrix MetalloProtease MMP-1 in vitro on fibroblasts and ex vivo on skin explants. OBJECTIVE In the present study, TFP properties were evaluated in a clinical assay. METHODS Twenty-two volunteers applied a TFP-based cream on one hemi-face and a placebo-based cream on the other hemi-face, twice a day during 28 days, before undergoing a surgical lifting. Cutometry and skin relief measurements were performed at days 0 and 28, and skin explants from lifting surgery were used for histological analyses. RESULTS Cutometry and skin relief measurements reveal TFP firming properties and wrinkle depth decrease in 28 days on TFP- as compared to placebo-treated hemi-faces. These results are confirmed by histological analyses showing an increase of the ratio between basal lamina and stratum corneum. Furthermore, immunostaining of collagen reveals a modification of the ratio between type I and III collagens. CONCLUSION The combined analysis of phenotypic and histologic parameters demonstrates a reorganization of the ECM towards a regenerative profile upon TFP treatment.
Collapse
Affiliation(s)
| | | | | | - Gaetan Thiery
- Centre Massilien de la face24 avenue du Prado, 13008 Marseille, France
| | | | - Bruno Alfandari
- Polyclinique Bordeaux Tondu143-153 rue du Tondu, 33082 Bordeaux, France
| | - Ivan Courtois
- Polyclinique Jean Villar56 av Maryse Bastié, 33520 Bruges, France
| | - Armand Azencot
- Clinique chirurgicale Bel-Air138 Av de la république, 33073 Bordeaux, France
| | - Vincent Casoli
- CHU de Bordeaux, Pole des spécialités chirurgicales, Service de chirurgie plastique brûlés main33000 Bordeaux, France
| | - Pierre Haen
- Hôpital d’instruction des armées Laveran (HIA)34 Boulevard Laveran, 13013 Marseille, France
| | | | | | - Didier Ritter
- Regentis-Pharma8bis rue Gabriel Voisin, 51100 Reims, France
| |
Collapse
|
45
|
Rikihisa N, Mitsukawa N, Rikhisa H, Nakao M. A new surgical tape with a mesh designed to prevent skin tears and reduce pain during tape removal. PLoS One 2023; 18:e0288304. [PMID: 37428790 DOI: 10.1371/journal.pone.0288304] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/05/2022] [Accepted: 06/14/2023] [Indexed: 07/12/2023] Open
Abstract
We devised a surgical tape that prevents skin tears while maintaining adhesive strength. Under the assumption that microscopic damage to the skin is reflected in pain felt on the skin, we statistically analyzed skin pain when the tape was peeled off to show the skin protection effect of the mesh on the new tape. This tape has a three-layer structure consisting of a tape substrate, adhesive, and mesh. When the tape is applied to the skin, a mesh is located between the adhesive and the skin. The adhesive contacts the skin through the mesh holes and fixes the substrate to the skin; it does not come into contact with the skin at the mesh body; therefore, the adhesive-skin contact area is reduced. In this experiment, we used surgical tape with and without mesh. At 8 hours after the application of each tape to the forearm of five adult males, it was removed. All tapes were peeled off while maintaining an angle of approximately 120° between the skin and tape substrate. For the tape with mesh, the tape substrate was peeled off in two ways: peeling off the substrate together with the mesh and peeling off the substrate, leaving the mesh on the skin. A perception and pain quantification analyzer (Pain Vision™) was used to quantify pain. The data were compared and examined statistically (Friedman's test and Wilcoxon's coded rank test). The least pain was experienced while peeling off the tape substrate, leaving the mesh on the skin. There was a significant difference in pain levels among the three tape removal methods. There was also a significant difference between the two peeling methods in the experimental group. The skin protection effect of the mesh reduced pain when the surgical tape was removed.
Collapse
Affiliation(s)
- Naoaki Rikihisa
- Oyumio Central Hospital, Chiba, Japan
- Tokyo Medical Tape, Yokohama, Japan
| | - Nobuyuki Mitsukawa
- Department of Plastic, Reconstructive, and Aesthetic Surgery, Chiba University Graduate School of Medicine, Chiba, Japan
| | - Hiroaki Rikhisa
- Research and Development Division, Furukawa Electric, Yokohama, Japan
| | - Masayuki Nakao
- School of Engineering, The University of Tokyo, Tokyo, Japan
| |
Collapse
|
46
|
Ittycheri A, Lipsky ZW, Hookway TA, German GK. Ultraviolet light induces mechanical and structural changes in full thickness human skin. J Mech Behav Biomed Mater 2023; 143:105880. [PMID: 37172426 DOI: 10.1016/j.jmbbm.2023.105880] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/12/2023] [Revised: 03/07/2023] [Accepted: 04/30/2023] [Indexed: 05/15/2023]
Abstract
While the detrimental health effects of prolonged ultraviolet (UV) irradiation on skin health have been widely accepted, the biomechanical process by which photoaging occurs and the relative effects of irradiation with different UV ranges on skin biomechanics have remained relatively unexplored. In this study, the effects of UV-induced photoageing are explored by quantifying the changes in the mechanical properties of full-thickness human skin irradiated with UVA and UVB light for incident dosages up to 1600 J/cm2. Mechanical testing of skin samples excised parallel and perpendicular to the predominant collagen fiber orientation show a rise in the fractional relative difference of elastic modulus, fracture stress, and toughness with increased UV irradiation. These changes become significant with UVA incident dosages of 1200 J/cm2 for samples excised both parallel and perpendicular to the dominant collagen fiber orientation. However, while mechanical changes occur in samples aligned with the collagen orientation at UVB dosages of 1200 J/cm2, statistical differences in samples perpendicular to the collagen orientation emerge only for UVB dosages of 1600 J/cm2. No notable or consistent trend is observed for the fracture strain. Analyses of toughness changes with maximum absorbed dosage reveals that no one UV range is more impactful in inducing mechanical property changes, but rather these changes scale with maximum absorbed energy. Evaluation of the structural characteristics of collagen further reveals an increase in collagen fiber bundle density with UV irradiation, but not collagen tortuosity, potentially linking mechanical changes to altered microstructure.
Collapse
Affiliation(s)
- Abraham Ittycheri
- Department of Biomedical Engineering, Binghamton University, State University of New York, Binghamton, NY, USA
| | - Zachary W Lipsky
- Department of Biomedical Engineering, Binghamton University, State University of New York, Binghamton, NY, USA
| | - Tracy A Hookway
- Department of Biomedical Engineering, Binghamton University, State University of New York, Binghamton, NY, USA
| | - Guy K German
- Department of Biomedical Engineering, Binghamton University, State University of New York, Binghamton, NY, USA.
| |
Collapse
|
47
|
Alloisio M, Chatziefraimidou M, Roy J, Christian Gasser T. Fracture of the porcine aorta. Part 1: symconCT fracture testing and DIC. Acta Biomater 2023:S1742-7061(23)00347-1. [PMID: 37355178 DOI: 10.1016/j.actbio.2023.06.022] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/23/2023] [Revised: 06/16/2023] [Accepted: 06/16/2023] [Indexed: 06/26/2023]
Abstract
Tissue failure and damage are inherent parts of vascular diseases and tightly linked to clinical events. Additionally, experimental set-ups designed to study classical engineering materials are suboptimal in the exploration of vessel wall fracture properties. The classical Compact Tension (CT) test was augmented to enable stable fracture propagation, resulting in the symmetry-constraint Compact Tension (symconCT) test, a suitable set-up for fracture testing of vascular tissue. The test was combined with Digital Image Correlation (DIC) to study tissue fracture in 45 porcine aorta specimens. Test specimens were loaded in axial and circumferential directions in a physiological solution at 37∘ C. Loading the aortic vessel wall in the axial direction resulted in mode I tissue failure and a fracture path aligned with the circumferential vessel direction. Circumferential loading resulted in mode I-dominated failure with multiple deflections of the fracture path. The aorta ruptured at a principal Green-Lagrange strain of approximately 0.7, and strain rate peaks that develop ahead of the crack tip reached nearly 400 times the strain rate on average over the test specimen. It required approximately 70% more external work to fracture the aorta by circumferential than axial load; normalised with the fracture surface, similar energy levels are, however, observed. The symconCT test resulted in a stable fracture propagation, which, combined with DIC, provided a set-up for the in-depth analysis of vascular tissue failure. The high strain rates ahead of the crack tip indicate the significance of rate effects in the constitutive description of vascular tissue fracture. STATEMENT OF SIGNIFICANCE: This paper represents a significant step forward in understanding the fracture properties of porcine aorta. Inspired by the Compact Tension test, we developed an ad hoc experimental protocol to investigate stable crack propagation in soft materials, providing new insights into the mechanical processes that lead to the rupture of vascular tissue. The set-up enables the assessment of strains and strain rates ahead of the crack tip, and our findings could improve the clinical risk assessment of vascular pathologies as well as optimize medical device design.
Collapse
Affiliation(s)
- Marta Alloisio
- Solid Mechanics, Department of Engineering Mechanics, KTH Royal Institute of Technology, Sweden
| | - Marina Chatziefraimidou
- Solid Mechanics, Department of Engineering Mechanics, KTH Royal Institute of Technology, Sweden
| | - Joy Roy
- Department of Molecular Medicine and Surgery, KI Karolinska Institute, Sweden
| | - T Christian Gasser
- Solid Mechanics, Department of Engineering Mechanics, KTH Royal Institute of Technology, Sweden.
| |
Collapse
|
48
|
Monfette V, Choinière W, Godbout-Lavoie C, Pelletier S, Langelier È, Lauzon MA. Thermoelectric Freeze-Casting of Biopolymer Blends: Fabrication and Characterization of Large-Size Scaffolds for Nerve Tissue Engineering Applications. J Funct Biomater 2023; 14:330. [PMID: 37367294 DOI: 10.3390/jfb14060330] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/08/2023] [Revised: 06/03/2023] [Accepted: 06/16/2023] [Indexed: 06/28/2023] Open
Abstract
Peripheral nerve injuries (PNIs) are detrimental to the quality of life of affected individuals. Patients are often left with life-long ailments that affect them physically and psychologically. Autologous nerve transplant is still the gold standard treatment for PNIs despite limited donor site and partial recovery of nerve functions. Nerve guidance conduits are used as a nerve graft substitute and are efficient for the repair of small nerve gaps but require further improvement for repairs exceeding 30 mm. Freeze-casting is an interesting fabrication method for the conception of scaffolds meant for nerve tissue engineering since the microstructure obtained comprises highly aligned micro-channels. The present work focuses on the fabrication and characterization of large scaffolds (35 mm length, 5 mm diameter) made of collagen/chitosan blends by freeze-casting via thermoelectric effect instead of traditional freezing solvents. As a freeze-casting microstructure reference, scaffolds made from pure collagen were used for comparison. Scaffolds were covalently crosslinked for better performance under load and laminins were further added to enhance cell interactions. Microstructural features of lamellar pores display an average aspect ratio of 0.67 ± 0.2 for all compositions. Longitudinally aligned micro-channels are reported as well as enhanced mechanical properties in traction under physiological-like conditions (37 °C, pH = 7.4) resulting from crosslinking treatment. Cell viability assays using a rat Schwann cell line derived from sciatic nerve (S16) indicate that scaffold cytocompatibility is similar between scaffolds made from collagen only and scaffolds made from collagen/chitosan blend with high collagen content. These results confirm that freeze-casting via thermoelectric effect is a reliable manufacturing strategy for the fabrication of biopolymer scaffolds for future peripheral nerve repair applications.
Collapse
Affiliation(s)
- Vincent Monfette
- Department of Chemical Engineering and Biotechnological of Engineering, Faculty of Engineering, Université de Sherbrooke, Sherbrooke, QC J1K 2R1, Canada
| | - William Choinière
- Department of Chemical Engineering and Biotechnological of Engineering, Faculty of Engineering, Université de Sherbrooke, Sherbrooke, QC J1K 2R1, Canada
| | - Catherine Godbout-Lavoie
- Department of Chemical Engineering and Biotechnological of Engineering, Faculty of Engineering, Université de Sherbrooke, Sherbrooke, QC J1K 2R1, Canada
| | - Samuel Pelletier
- Department of Electrical Engineering and Informatics Engineering, Faculty of Engineering, Université de Sherbrooke, Sherbrooke, QC J1K 2R1, Canada
| | - Ève Langelier
- Department of Mechanical Engineering, Faculty of Engineering, Université de Sherbrooke, Sherbrooke, QC J1K 2R1, Canada
| | - Marc-Antoine Lauzon
- Department of Chemical Engineering and Biotechnological of Engineering, Faculty of Engineering, Université de Sherbrooke, Sherbrooke, QC J1K 2R1, Canada
- Research Center on Aging, CIUSSS de l'ESTRIE-CHUS, Sherbrooke, QC J1H 4C4, Canada
| |
Collapse
|
49
|
Sasaki Y, Nishizawa Y, Watanabe T, Kureha T, Uenishi K, Nakazono K, Takata T, Suzuki D. Nanoparticle-Based Tough Polymers with Crack-Propagation Resistance. LANGMUIR : THE ACS JOURNAL OF SURFACES AND COLLOIDS 2023. [PMID: 37327130 DOI: 10.1021/acs.langmuir.3c01226] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/18/2023]
Abstract
Although thin elastomer films of polymer nanoparticles are regarded as environmentally friendly materials, the low mechanical strength of the films limits their use in various applications. In the present study, we investigated the fracture resistance of latex films composed of acrylic nanoparticles where a small quantity of a rotaxane crosslinker was introduced. In contrast to conventional nanoparticle-based elastomers, the latex films composed of the rotaxane-crosslinked nanoparticles exhibited unusual crack propagation behavior; the direction of crack propagation changed from a direction parallel to the crack to one perpendicular to the crack, resulting in an increase in tear resistance. These findings will help to broaden the scope of design of new types of tough polymers composed of environmentally friendly polymer nanoparticles.
Collapse
Affiliation(s)
- Yuma Sasaki
- Graduate School of Textile Science & Technology, Shinshu University, 3-15-1 Tokida, Ueda, Nagano 386-8567, Japan
| | - Yuichiro Nishizawa
- Graduate School of Textile Science & Technology, Shinshu University, 3-15-1 Tokida, Ueda, Nagano 386-8567, Japan
| | - Takumi Watanabe
- Graduate School of Textile Science & Technology, Shinshu University, 3-15-1 Tokida, Ueda, Nagano 386-8567, Japan
| | - Takuma Kureha
- Department of Frontier Materials Chemistry, Graduate School of Science and Technology, Hirosaki University, 3 Bunkyo-cho, Hirosaki 036-8561, Japan
| | - Kazuya Uenishi
- Yokohama Rubber Co., Ltd., 2-1 Oiwake, Hiratsuka, Kanagawa 254-8601, Japan
| | - Kazuko Nakazono
- Department of Chemical Science and Engineering, Tokyo Institute of Technology, 4259 Nagatsuta-cho, Midori-ku, Yokohama, Kanagawa 226-8503, Japan
| | - Toshikazu Takata
- Department of Chemical Science and Engineering, Tokyo Institute of Technology, 4259 Nagatsuta-cho, Midori-ku, Yokohama, Kanagawa 226-8503, Japan
- Graduate School of Advanced Science and Engineering, Hiroshima University, 1-4-1 Kagamiyama, Higashi-Hiroshima, Hiroshima 739-8527, Japan
| | - Daisuke Suzuki
- Graduate School of Textile Science & Technology, Shinshu University, 3-15-1 Tokida, Ueda, Nagano 386-8567, Japan
- Research Initiative for Supra-Materials, Interdisciplinary Cluster for Cutting Edge Research, Shinshu University, 3-15-1 Tokida, Ueda, Nagano 386-8567, Japan
| |
Collapse
|
50
|
Stan D, Codrici E, Enciu AM, Olewnik-Kruszkowska E, Gavril G, Ruta LL, Moldovan C, Brincoveanu O, Bocancia-Mateescu LA, Mirica AC, Stan D, Tanase C. Exploring the Impact of Alginate-PVA Ratio and the Addition of Bioactive Substances on the Performance of Hybrid Hydrogel Membranes as Potential Wound Dressings. Gels 2023; 9:476. [PMID: 37367146 DOI: 10.3390/gels9060476] [Citation(s) in RCA: 2] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/26/2023] [Revised: 06/07/2023] [Accepted: 06/08/2023] [Indexed: 06/28/2023] Open
Abstract
Healthcare professionals face an ongoing challenge in managing both acute and chronic wounds, given the potential impact on patients' quality of life and the limited availability of expensive treatment options. Hydrogel wound dressings offer a promising solution for effective wound care due to their affordability, ease of use, and ability to incorporate bioactive substances that enhance the wound healing process. Our study aimed to develop and evaluate hybrid hydrogel membranes enriched with bioactive components such as collagen and hyaluronic acid. We utilized both natural and synthetic polymers and employed a scalable, non-toxic, and environmentally friendly production process. We conducted extensive testing, including an in vitro assessment of moisture content, moisture uptake, swelling rate, gel fraction, biodegradation, water vapor transmission rate, protein denaturation, and protein adsorption. We evaluated the biocompatibility of the hydrogel membranes through cellular assays and performed instrumental tests using scanning electron microscopy and rheological analysis. Our findings demonstrate that the biohybrid hydrogel membranes exhibit cumulative properties with a favorable swelling ratio, optimal permeation properties, and good biocompatibility, all achieved with minimal concentrations of bioactive agents.
Collapse
Affiliation(s)
- Diana Stan
- DDS Diagnostic, 031427 Bucharest, Romania
- Doctoral School of Medicine, Titu Maiorescu University, 040441 Bucharest, Romania
| | - Elena Codrici
- Victor Babes National Institute of Pathology, 050096 Bucharest, Romania
| | - Ana-Maria Enciu
- Victor Babes National Institute of Pathology, 050096 Bucharest, Romania
- Department of Cell Biology and Histology, Carol Davila University of Medicine and Pharmacy, 050474 Bucharest, Romania
| | - Ewa Olewnik-Kruszkowska
- Department of Physical Chemistry and Physicochemistry of Polymers, Faculty of Chemistry, Nicolaus Copernicus University, 87-100 Toruń, Poland
| | - Georgiana Gavril
- Department of Bioinformatics, National Institute of Research and Development for Biological Sciences, 060031 Bucharest, Romania
| | | | - Carmen Moldovan
- National Institute for R&D in Microtechnology, 077190 Bucharest, Romania
| | - Oana Brincoveanu
- National Institute for R&D in Microtechnology, 077190 Bucharest, Romania
- Research Institute of the University of Bucharest, 060102 Bucharest, Romania
| | | | | | - Dana Stan
- DDS Diagnostic, 031427 Bucharest, Romania
| | - Cristiana Tanase
- Victor Babes National Institute of Pathology, 050096 Bucharest, Romania
- Department of Cell Biology and Clinical Biochemistry, Faculty of Medicine, Titu Maiorescu University, 040441 Bucharest, Romania
| |
Collapse
|