1
|
Maharjan S, Ma C, Singh B, Kang H, Orive G, Yao J, Shrike Zhang Y. Advanced 3D imaging and organoid bioprinting for biomedical research and therapeutic applications. Adv Drug Deliv Rev 2024; 208:115237. [PMID: 38447931 PMCID: PMC11031334 DOI: 10.1016/j.addr.2024.115237] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/08/2023] [Revised: 01/15/2024] [Accepted: 02/27/2024] [Indexed: 03/08/2024]
Abstract
Organoid cultures offer a valuable platform for studying organ-level biology, allowing for a closer mimicry of human physiology compared to traditional two-dimensional cell culture systems or non-primate animal models. While many organoid cultures use cell aggregates or decellularized extracellular matrices as scaffolds, they often lack precise biochemical and biophysical microenvironments. In contrast, three-dimensional (3D) bioprinting allows precise placement of organoids or spheroids, providing enhanced spatial control and facilitating the direct fusion for the formation of large-scale functional tissues in vitro. In addition, 3D bioprinting enables fine tuning of biochemical and biophysical cues to support organoid development and maturation. With advances in the organoid technology and its potential applications across diverse research fields such as cell biology, developmental biology, disease pathology, precision medicine, drug toxicology, and tissue engineering, organoid imaging has become a crucial aspect of physiological and pathological studies. This review highlights the recent advancements in imaging technologies that have significantly contributed to organoid research. Additionally, we discuss various bioprinting techniques, emphasizing their applications in organoid bioprinting. Integrating 3D imaging tools into a bioprinting platform allows real-time visualization while facilitating quality control, optimization, and comprehensive bioprinting assessment. Similarly, combining imaging technologies with organoid bioprinting can provide valuable insights into tissue formation, maturation, functions, and therapeutic responses. This approach not only improves the reproducibility of physiologically relevant tissues but also enhances understanding of complex biological processes. Thus, careful selection of bioprinting modalities, coupled with appropriate imaging techniques, holds the potential to create a versatile platform capable of addressing existing challenges and harnessing opportunities in these rapidly evolving fields.
Collapse
Affiliation(s)
- Sushila Maharjan
- Division of Engineering in Medicine, Department of Medicine, Brigham and Women's Hospital, Harvard Medical School, Cambridge, MA 02139, USA
| | - Chenshuo Ma
- Department of Biomedical Engineering, Duke University, Durham, NC 27708, USA
| | - Bibhor Singh
- Winthrop L. Chenery Upper Elementary School, Belmont, MA 02478, USA
| | - Heemin Kang
- Department of Materials Science and Engineering, Korea University, Seoul 02841, Republic of Korea; College of Medicine, Korea University, Seoul 02841, Republic of Korea
| | - Gorka Orive
- NanoBioCel Research Group, School of Pharmacy, University of the Basque Country (UPV/EHU), Vitoria-Gasteiz, Spain; Bioaraba, NanoBioCel Research Group, Vitoria-Gasteiz, Spain; Biomedical Research Networking Centre in Bioengineering, Biomaterials and Nanomedicine (CIBER-BBN). Vitoria-Gasteiz, Spain; University Institute for Regenerative Medicine and Oral Implantology - UIRMI (UPV/EHU-Fundación Eduardo Anitua), Vitoria, 01007, Spain; Singapore Eye Research Institute, The Academia, 20 College Road, Discovery Tower, Singapore 169856, Singapore
| | - Junjie Yao
- Department of Biomedical Engineering, Duke University, Durham, NC 27708, USA.
| | - Yu Shrike Zhang
- Division of Engineering in Medicine, Department of Medicine, Brigham and Women's Hospital, Harvard Medical School, Cambridge, MA 02139, USA.
| |
Collapse
|
2
|
Weng ST, Lai QL, Cai MT, Wang JJ, Zhuang LY, Cheng L, Mo YJ, Liu L, Zhang YX, Qiao S. Detecting vulnerable carotid plaque and its component characteristics: Progress in related imaging techniques. Front Neurol 2022; 13:982147. [PMID: 36188371 PMCID: PMC9515377 DOI: 10.3389/fneur.2022.982147] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/30/2022] [Accepted: 08/29/2022] [Indexed: 11/30/2022] Open
Abstract
Carotid atherosclerotic plaque rupture and thrombosis are independent risk factors for acute ischemic cerebrovascular disease. Timely identification of vulnerable plaque can help prevent stroke and provide evidence for clinical treatment. Advanced invasive and non-invasive imaging modalities such as computed tomography, magnetic resonance imaging, intravascular ultrasound, optical coherence tomography, and near-infrared spectroscopy can be employed to image and classify carotid atherosclerotic plaques to provide clinically relevant predictors used for patient risk stratification. This study compares existing clinical imaging methods, and the advantages and limitations of different imaging techniques for identifying vulnerable carotid plaque are reviewed to effectively prevent and treat cerebrovascular diseases.
Collapse
Affiliation(s)
- Shi-Ting Weng
- The Second Clinical Medical College, Zhejiang Chinese Medicine University, Hangzhou, China
| | - Qi-Lun Lai
- Department of Neurology, Zhejiang Hospital, Hangzhou, China
| | - Meng-Ting Cai
- Department of Neurology, Second Affiliated Hospital, School of Medicine, Zhejiang University, Hangzhou, China
| | - Jun-Jun Wang
- Department of Neurology, Zhejiang Hospital, Hangzhou, China
| | - Li-Ying Zhuang
- Department of Neurology, Zhejiang Hospital, Hangzhou, China
| | - Lin Cheng
- Department of Neurology, Zhejiang Hospital, Hangzhou, China
| | - Ye-Jia Mo
- Department of Neurology, Zhejiang Hospital, Hangzhou, China
| | - Lu Liu
- Department of Neurology, Zhejiang Hospital, Hangzhou, China
| | - Yin-Xi Zhang
- Department of Neurology, Second Affiliated Hospital, School of Medicine, Zhejiang University, Hangzhou, China
- *Correspondence: Yin-Xi Zhang
| | - Song Qiao
- Department of Neurology, Zhejiang Hospital, Hangzhou, China
- Song Qiao
| |
Collapse
|
3
|
Fei K, Zhang J, Yuan J, Xiao P. Present Application and Perspectives of Organoid Imaging Technology. Bioengineering (Basel) 2022; 9:bioengineering9030121. [PMID: 35324810 PMCID: PMC8945799 DOI: 10.3390/bioengineering9030121] [Citation(s) in RCA: 14] [Impact Index Per Article: 7.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/24/2022] [Revised: 02/23/2022] [Accepted: 03/13/2022] [Indexed: 11/18/2022] Open
Abstract
An organoid is a miniaturized and simplified in vitro model with a similar structure and function to a real organ. In recent years, the use of organoids has increased explosively in the field of growth and development, disease simulation, drug screening, cell therapy, etc. In order to obtain necessary information, such as morphological structure, cell function and dynamic signals, it is necessary and important to directly monitor the culture process of organoids. Among different detection technologies, imaging technology is a simple and convenient choice and can realize direct observation and quantitative research. In this review, the principle, advantages and disadvantages of imaging technologies that have been applied in organoids research are introduced. We also offer an overview of prospective technologies for organoid imaging. This review aims to help biologists find appropriate imaging techniques for different areas of organoid research, and also contribute to the development of organoid imaging systems.
Collapse
|
4
|
Samadi S, Dargahi J, Narayanswamy S. Design and Optimization of a Linear Wavenumber Spectrometer with Cylindrical Optics for Line Scanning Optical Coherence Tomography. SENSORS 2021; 21:s21196463. [PMID: 34640783 PMCID: PMC8511992 DOI: 10.3390/s21196463] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 07/26/2021] [Revised: 09/11/2021] [Accepted: 09/24/2021] [Indexed: 11/16/2022]
Abstract
We report the design of a high-efficiency spectral-domain spectrometer with cylindrical optics for line scanning optical coherence tomography (OCT). The spectral nonlinearity in k space (wavenumber) lowers the depth-dependent signal sensitivity of the spectrometers. For linearizing, in this design, grating and prism have been introduced. For line scanning, a cylindrical mirror is utilized in the scanning part. Line scanning improves the speed of imaging compared to fly-spot scanning. Line scanning OCT requires a spectrometer that utilizes cylindrical optics. In this work, an optical design of a linear wavenumber spectrometer with cylindrical optics is introduced. While there are many works using grating and prism to linearize the K space spectrometer design, there is no work on linearizing the k-space spectrometer with cylindrical optics for line scanning that provides high sensitivity and high-speed imaging without the need for resampling. The design of the spectrometer was achieved through MATLAB and ZEMAX simulations. The spectrometer design is optimized for the broadband light source with a center wavelength of 830 ± 100 nm (8.607 μm-1- 6.756 μm-1 in k-space). The variation in the output angle with respect to the wavenumber can be mentioned as a nonlinearity error. From our design results, it is observed that the nonlinearity error reduced from 147.0115 to 0.0149 Δθ*μm within the wavenumber range considered. The use of the proposed reflective optics for focusing reduces the chromatic aberration and increases image quality (measured by the Strehl ratio (SR)). The complete system will provide clinicians a powerful tool for real-time diagnosis, treatment, and guidance in surgery with high image quality for in-vivo applications.
Collapse
|
5
|
Du M, Loetgering L, Eikema KSE, Witte S. Ptychographic optical coherence tomography. OPTICS LETTERS 2021; 46:1337-1340. [PMID: 33720181 DOI: 10.1364/ol.416144] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 11/30/2020] [Accepted: 02/10/2021] [Indexed: 06/12/2023]
Abstract
Ptychography is a robust computational imaging technique that can reconstruct complex light fields beyond conventional hardware limits. However, for many wide-field computational imaging techniques, including ptychography, depth sectioning remains a challenge. Here we demonstrate a high-resolution three-dimensional (3D) computational imaging approach, which combines ptychography with spectral-domain imaging, inspired by optical coherence tomography (OCT). This results in a flexible imaging system with the main advantages of OCT, such as depth-sectioning without sample rotation, decoupling of transverse and axial resolution, and a high axial resolution only determined by the source bandwidth. The interferometric reference needed in OCT is replaced by computational methods, simplifying hardware requirements. As ptychography is capable of deconvolving the illumination contributions in the observed signal, speckle-free images are obtained. We demonstrate the capabilities of ptychographic optical coherence tomography (POCT) by imaging an axially discrete lithographic structure and an axially continuous mouse brain sample.
Collapse
|
6
|
Brunet J, Pierrat B, Badel P. Review of Current Advances in the Mechanical Description and Quantification of Aortic Dissection Mechanisms. IEEE Rev Biomed Eng 2021; 14:240-255. [PMID: 31905148 DOI: 10.1109/rbme.2019.2950140] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/05/2022]
Abstract
Aortic dissection is a life-threatening event associated with a very poor outcome. A number of complex phenomena are involved in the initiation and propagation of the disease. Advances in the comprehension of the mechanisms leading to dissection have been made these last decades, thanks to improvements in imaging and experimental techniques. However, the micro-mechanics involved in triggering such rupture events remains poorly described and understood. It constitutes the primary focus of the present review. Towards the goal of detailing the dissection phenomenon, different experimental and modeling methods were used to investigate aortic dissection, and to understand the underlying phenomena involved. In the last ten years, research has tended to focus on the influence of microstructure on initiation and propagation of the dissection, leading to a number of multiscale models being developed. This review brings together all these materials in an attempt to identify main advances and remaining questions.
Collapse
|
7
|
Li X, Zhang W, Wang WY, Wu X, Li Y, Tan X, Matera DL, Baker BM, Paulus YM, Fan X, Wang X. Optical coherence tomography and fluorescence microscopy dual-modality imaging for in vivo single-cell tracking with nanowire lasers. BIOMEDICAL OPTICS EXPRESS 2020; 11:3659-3672. [PMID: 33014558 PMCID: PMC7510899 DOI: 10.1364/boe.395369] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 04/16/2020] [Revised: 06/02/2020] [Accepted: 06/03/2020] [Indexed: 05/24/2023]
Abstract
Emerging cell-based therapies such as stem cell therapy and immunotherapy have attracted broad attention in both biological research and clinical practice. However, a long-standing technical gap of cell-based therapies is the difficulty of directly assessing treatment efficacy via tracking therapeutically administered cells. Therefore, imaging techniques to follow the in vivo distribution and migration of cells are greatly needed. Optical coherence tomography (OCT) is a clinically available imaging technology with ultrahigh-resolution and excellent imaging depth. It also shows great potential for in vivo cellular imaging. However, due to the homogeneity of current OCT cell labeling contrast agents (such as gold and polymer nanoparticles), only the distribution of entire cell populations can be observed. Precise tracking of the trajectory of individual single cells is not possible with such conventional contrast agents. Microlasers may provide a route to track unique cell identifiers given their small size, high emission intensities, rich emission spectra, and narrow linewidths. Here, we demonstrate that nanowire lasers internalized by cells provide both OCT and fluorescence signal. In addition, cells can be individually identified by the unique lasing emission spectra of the nanowires that they carry. Furthermore, single cell migration trajectories can be monitored both in vitro and in vivo with OCT and fluorescence microscopy dual-modality imaging system. Our study demonstrates the feasibility of nanowire lasers combined with the dual-modality imaging system for in vivo single cell tracking with a high spatial resolution and identity verification, an approach with great utility for stem cell and immunomodulatory therapies.
Collapse
Affiliation(s)
- Xuzhou Li
- Department of Biomedical Engineering, University of Michigan, 1101 Beal Ave., Ann Arbor, MI 48109, USA
- Department of Mechanical Engineering, University of Michigan, 2350 Hayward St., Ann Arbor, MI 48109, USA
- Xuzhou Li and Wei Zhang contributed equally to this work
| | - Wei Zhang
- Department of Biomedical Engineering, University of Michigan, 1101 Beal Ave., Ann Arbor, MI 48109, USA
- Xuzhou Li and Wei Zhang contributed equally to this work
| | - William Y Wang
- Department of Biomedical Engineering, University of Michigan, 1101 Beal Ave., Ann Arbor, MI 48109, USA
| | - Xiaoqin Wu
- Department of Biomedical Engineering, University of Michigan, 1101 Beal Ave., Ann Arbor, MI 48109, USA
| | - Yanxiu Li
- Department of Ophthalmology and Visual Sciences, University of Michigan, 1000 Wall St, Ann Arbor, MI 48105, USA
| | - Xiaotian Tan
- Department of Biomedical Engineering, University of Michigan, 1101 Beal Ave., Ann Arbor, MI 48109, USA
| | - Daniel L Matera
- Department of Biomedical Engineering, University of Michigan, 1101 Beal Ave., Ann Arbor, MI 48109, USA
| | - Brendon M Baker
- Department of Biomedical Engineering, University of Michigan, 1101 Beal Ave., Ann Arbor, MI 48109, USA
| | - Yannis M Paulus
- Department of Biomedical Engineering, University of Michigan, 1101 Beal Ave., Ann Arbor, MI 48109, USA
- Department of Ophthalmology and Visual Sciences, University of Michigan, 1000 Wall St, Ann Arbor, MI 48105, USA
| | - Xudong Fan
- Department of Biomedical Engineering, University of Michigan, 1101 Beal Ave., Ann Arbor, MI 48109, USA
| | - Xueding Wang
- Department of Biomedical Engineering, University of Michigan, 1101 Beal Ave., Ann Arbor, MI 48109, USA
| |
Collapse
|
8
|
Fabelo C, Selmic LE, Huang PC, Samuelson JP, Reagan JK, Kalamaras A, Wavreille V, Monroy GL, Marjanovic M, Boppart SA. Evaluating optical coherence tomography for surgical margin assessment of canine mammary tumours. Vet Comp Oncol 2020; 19:697-706. [PMID: 32562330 DOI: 10.1111/vco.12632] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/31/2020] [Revised: 06/11/2020] [Accepted: 06/17/2020] [Indexed: 12/20/2022]
Abstract
Optical coherence tomography (OCT) uses near-infrared light waves to generate real-time, high-resolution images on the microscopic scale similar to low power histopathology. Previous studies have demonstrated the use of OCT for real-time surgical margin assessment for human breast cancer. The use of OCT for canine mammary tumours (CMT) could allow intra-operative visualisation of residual tumour at the surgical margins. The purpose of this study was to assess OCT imaging for the detection of incomplete tumour resection following CMT surgery. We hypothesized that the OCT images would have comparable features to histopathological images of tissues at the surgical margins of CMT resections along with a high sensitivity of OCT detection of incomplete surgical excision of CMT. Thirty surgical specimens were obtained from nineteen client-owned dogs undergoing surgical resection of CMT. OCT image appearance and characteristics of adipose tissue, skin, mammary tissue and mammary tumour at the surgical margins were distinct and different. The OCT images of normal and abnormal tissues at the surgical margins were utilized to develop a dataset of OCT images for observer evaluation. The sensitivity and specificity for ex vivo images were 83.3% and 82.0% (observer 1) and 70.0% and 67.9% (observer 2). The sensitivity and specificity for in vivo images were 70.0% and 89.3% (observer 1) and 76.7% and 67.9% (observer 2). These results indicate a potential use of OCT for surgical margin assessment for CMT to optimize surgical intervention and clinical outcomes. Improved training and experience of observers may improve sensitivity and specificity.
Collapse
Affiliation(s)
- Carolina Fabelo
- Department of Veterinary Clinical Sciences, College of Veterinary Medicine, Ohio State University, Columbus, Ohio, USA
| | - Laura E Selmic
- Department of Veterinary Clinical Sciences, College of Veterinary Medicine, Ohio State University, Columbus, Ohio, USA
| | - Pin-Cheh Huang
- Department of Bioengineering, University of Illinois at Urbana-Champaign, Champaign, Illinois, USA.,Beckman Institute for Advanced Science and Technology, University of Illinois at Urbana-Champaign, Champaign, Illinois, USA
| | - Jonathan P Samuelson
- Department of Veterinary Clinical Medicine, University of Illinois at Urbana-Champaign, Urbana, Illinois, USA
| | - Jennifer K Reagan
- Department of Surgery, Seattle Veterinary Specialists-Downtown, Seattle, Washington, USA
| | - Alexandra Kalamaras
- Department of Veterinary Clinical Sciences, College of Veterinary Medicine, Ohio State University, Columbus, Ohio, USA
| | - Vincent Wavreille
- Department of Veterinary Clinical Sciences, College of Veterinary Medicine, Ohio State University, Columbus, Ohio, USA
| | - Guillermo L Monroy
- Department of Bioengineering, University of Illinois at Urbana-Champaign, Champaign, Illinois, USA.,Beckman Institute for Advanced Science and Technology, University of Illinois at Urbana-Champaign, Champaign, Illinois, USA
| | - Marina Marjanovic
- Department of Bioengineering, University of Illinois at Urbana-Champaign, Champaign, Illinois, USA.,Beckman Institute for Advanced Science and Technology, University of Illinois at Urbana-Champaign, Champaign, Illinois, USA.,Carle Illinois College of Medicine, University of Illinois at Urbana-Champaign, Champaign, Illinois, USA
| | - Stephen A Boppart
- Department of Bioengineering, University of Illinois at Urbana-Champaign, Champaign, Illinois, USA.,Beckman Institute for Advanced Science and Technology, University of Illinois at Urbana-Champaign, Champaign, Illinois, USA.,Carle Illinois College of Medicine, University of Illinois at Urbana-Champaign, Champaign, Illinois, USA.,Department of Electrical and Computer Engineering, University of Illinois at Urbana-Champaign, Champaign, Illinois, USA.,Cancer Center at Illinois, University of Illinois at Urbana-Champaign, Champaign, Illinois, USA
| |
Collapse
|
9
|
Wang TA, Chan MC, Lee HC, Lee CY, Tsai MT. Ultrahigh-resolution optical coherence tomography/angiography with an economic and compact supercontinuum laser. BIOMEDICAL OPTICS EXPRESS 2019; 10:5687-5702. [PMID: 31799040 PMCID: PMC6865110 DOI: 10.1364/boe.10.005687] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 07/05/2019] [Revised: 10/06/2019] [Accepted: 10/07/2019] [Indexed: 05/19/2023]
Abstract
In this study, a Q-switch pumped supercontinuum laser (QS-SCL) is used as a light source for in vivo imaging via ultrahigh-resolution optical coherence tomography and angiography (UHR-OCT/OCTA). For this purpose, an OCT system based on a spectral-domain detection scheme is constructed, and a spectrometer with a spectral range of 635 - 875 nm is designed. The effective full-width at half maximum of spectrum covers 150 nm, and the corresponding axial and transverse resolutions are 2 and 10 µm in air, respectively. The relative intensity noise of the QS-SCL and mode-locked SCL is quantitatively compared. Furthermore, a special processing algorithm is developed to eliminate the intrinsic noise of QS-SCL. This work demonstrates that QS-SCLs can effectively reduce the cost and size of UHR-OCT/OCTA instruments, making clinical applications feasible.
Collapse
Affiliation(s)
- Tai-Ang Wang
- Institute of Photonic System, College of Photonics, National Chiao-Tung University, Tainan City 71150, Taiwan
- The authors contributed equally to this work
| | - Ming-Che Chan
- Institute of Photonic System, College of Photonics, National Chiao-Tung University, Tainan City 71150, Taiwan
- The authors contributed equally to this work
| | - Hsiang-Chieh Lee
- Graduate Institute of Photonics and Optoelectronics, National Taiwan University, 10617, Taiwan
- Department of Electrical Engineering, National Taiwan University, Taipei 10617, Taiwan
| | - Cheng-Yu Lee
- Department of Electrical Engineering, Chang Gung University, Taoyuan 33302, Taiwan
| | - Meng-Tsan Tsai
- Department of Electrical Engineering, Chang Gung University, Taoyuan 33302, Taiwan
- Department of Neurosurgery, Chang Gung Memorial Hospital, Linkou, Taoyuan 33305, Taiwan
| |
Collapse
|
10
|
Schmidt H, Connolly C, Jaffer S, Oza T, Weltz CR, Port ER, Corben A. Evaluation of surgically excised breast tissue microstructure using wide-field optical coherence tomography. Breast J 2019; 26:917-923. [PMID: 31612563 DOI: 10.1111/tbj.13663] [Citation(s) in RCA: 12] [Impact Index Per Article: 2.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/03/2019] [Revised: 09/23/2019] [Accepted: 09/26/2019] [Indexed: 11/30/2022]
Abstract
BACKGROUND Currently, positive margins at lumpectomy contribute to health care cost, patient anxiety, and treatment delay. Multiple technology solutions are being explored with the aim of lowering re-excision rates for breast-conserving surgery (BCS). We examined wide-field optical coherence tomography (WF-OCT), an innovative adjunct intraoperative imaging tool for tissue visualization of margins. METHODS This IRB-approved pilot study included women with invasive or in situ carcinoma scheduled for primary BCS. Lumpectomy specimens and any final/revised margins were imaged by optical coherence tomography immediately prior to standard histological processing. The optical coherence tomography used provided two-dimensional, cross-sectional, real-time depth visualization of the margin widths around excised specimens. A volume of images was captured for 10 × 10 cm tissue surface at high resolution (sub-30 μm) to a depth of 2 mm. Integrated interpretation was performed incorporating final pathology linked with the optical image data for correlation. RESULTS Wide-field optical coherence tomography was performed on 185 tissue samples (50 lumpectomy specimens and 135 additional margin shaves) in 50 subjects. Initial diagnosis was invasive ductal carcinoma (IDC) in 10, ductal carcinoma in situ (DCIS) in 14, IDC/DCIS in 22, invasive lobular carcinoma (ILC) in 2, ILC/DCIS in 1, and sarcoma in 1. Optical coherence tomography was concordant with final pathology in 178/185 tissue samples for overall accuracy of 86% and 96.2% (main specimen alone and main specimen + shave margins). Of seven samples that were discordant, 57% (4/7) were considered close (DCIS < 2 mm from margin) per final pathology. CONCLUSION Wide-field optical coherence tomography demonstrated concordance with histology at tissue margins, supporting its potential for use as a real-time adjunct intraoperative imaging tool for margin assessment. Further studies are needed for comprehensive evaluation in the intraoperative setting.
Collapse
Affiliation(s)
- Hank Schmidt
- Dubin Breast Center of the Tisch Cancer Institute, Mount Sinai Hospital, New York, New York
| | - Courtney Connolly
- Dubin Breast Center of the Tisch Cancer Institute, Mount Sinai Hospital, New York, New York
| | - Shabnam Jaffer
- Dubin Breast Center of the Tisch Cancer Institute, Mount Sinai Hospital, New York, New York
| | - Twisha Oza
- Dubin Breast Center of the Tisch Cancer Institute, Mount Sinai Hospital, New York, New York
| | - Christina R Weltz
- Dubin Breast Center of the Tisch Cancer Institute, Mount Sinai Hospital, New York, New York
| | - Elisa R Port
- Dubin Breast Center of the Tisch Cancer Institute, Mount Sinai Hospital, New York, New York
| | - Adriana Corben
- Dubin Breast Center of the Tisch Cancer Institute, Mount Sinai Hospital, New York, New York
| |
Collapse
|
11
|
Cocca CJ, Selmic LE, Samuelson J, Huang PC, Wang J, Boppart SA. Comparison between optical coherence tomographic and histopathologic appearances of artifacts caused by common surgical conditions and instrumentation. Vet Surg 2019; 48:1361-1371. [PMID: 31390082 DOI: 10.1111/vsu.13305] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/30/2018] [Revised: 05/13/2019] [Accepted: 07/17/2019] [Indexed: 12/25/2022]
Abstract
OBJECTIVE To document the appearance of artifacts created by commonly encountered surgical conditions and instrumentation on optical coherence tomography (OCT) and to compare these findings with histopathology. STUDY DESIGN Ex vivo study. ANIMALS Five canine cadavers. METHODS Skin, subcutaneous fat, skeletal muscle, and fascia samples were obtained from fresh canine cadavers. Blood pooling, hemostatic crushing, scalpel blade cut, monopolar electrosurgery, bipolar vessel sealing device, and ultrasonic energy surgical artifacts were induced on each tissue type. Each specimen was imaged with OCT and subsequently histologically processed. RESULTS Most surgical instrumentation used for tumor excision created a high-scattering region with local architectural disruption. Blood pooling was visible as a high-scattering layer overlying tissue with normal architecture. Only the scalpel blade created a focal, low-scattering area representing a sharply demarcated cut within the tissue distinct from the appearance of other instrumentation. CONCLUSION Common surgical instruments and conditions encountered during tumor excision produced high-scattering OCT artifacts in tissues commonly seen at surgical margins. CLINICAL SIGNIFICANCE The clinical value of OCT hinges on the ability of personnel to interpret this novel imaging and recognize artifacts. Defining and describing the appearance of common surgical artifacts provides a foundation to create image libraries with known histological and OCT interpretation, ultimately improving the diagnostic accuracy of OCT for assessment of surgical margins.
Collapse
Affiliation(s)
- Christina J Cocca
- Department of Veterinary Clinical Medicine, University of Illinois Urbana-Champaign, Urbana, Illinois
| | - Laura E Selmic
- Department of Veterinary Clinical Medicine, University of Illinois Urbana-Champaign, Urbana, Illinois
| | - Jonathan Samuelson
- Department of Pathobiology, University of Illinois Urbana-Champaign, Urbana, Illinois
| | - Pin-Chieh Huang
- Beckman Institute for Advanced Science and Technology, University of Illinois Urbana-Champaign, Urbana, Illinois.,Department of Bioengineering, University of Illinois Urbana-Champaign, Urbana, Illinois
| | - Jianfeng Wang
- Beckman Institute for Advanced Science and Technology, University of Illinois Urbana-Champaign, Urbana, Illinois
| | - Stephen A Boppart
- Beckman Institute for Advanced Science and Technology, University of Illinois Urbana-Champaign, Urbana, Illinois.,Department of Bioengineering, University of Illinois Urbana-Champaign, Urbana, Illinois.,Department of Electrical and Computer Engineering, University of Illinois Urbana-Champaign, Urbana, Illinois.,Carle-Illinois College of Medicine, University of Illinois Urbana-Champaign, Urbana, Illinois
| |
Collapse
|
12
|
Liu L, Viel A, Le Saux G, Plawinski L, Muggiolu G, Barberet P, Pereira M, Ayela C, Seznec H, Durrieu MC, Olive JM, Audoin B. Remote imaging of single cell 3D morphology with ultrafast coherent phonons and their resonance harmonics. Sci Rep 2019; 9:6409. [PMID: 31015541 PMCID: PMC6478725 DOI: 10.1038/s41598-019-42718-5] [Citation(s) in RCA: 10] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/21/2019] [Accepted: 04/03/2019] [Indexed: 11/21/2022] Open
Abstract
Cell morphological analysis has long been used in cell biology and physiology for abnormality identification, early cancer detection, and dynamic change analysis under specific environmental stresses. This work reports on the remote mapping of cell 3D morphology with an in-plane resolution limited by optics and an out-of-plane accuracy down to a tenth of the optical wavelength. For this, GHz coherent acoustic phonons and their resonance harmonics were tracked by means of an ultrafast opto-acoustic technique. After illustrating the measurement accuracy with cell-mimetic polymer films we map the 3D morphology of an entire osteosarcoma cell. The resulting image complies with the image obtained by standard atomic force microscopy, and both reveal very close roughness mean values. In addition, while scanning macrophages and monocytes, we demonstrate an enhanced contrast of thickness mapping by taking advantage of the detection of high-frequency resonance harmonics. Illustrations are given with the remote quantitative imaging of the nucleus thickness gradient of migrating monocyte cells.
Collapse
Affiliation(s)
- Liwang Liu
- University of Bordeaux, CNRS UMR 5295, I2M, F-33400, Talence, France
| | - Alexis Viel
- University of Bordeaux, CNRS UMR 5295, I2M, F-33400, Talence, France
| | - Guillaume Le Saux
- University of Bordeaux, CNRS UMR 5248, Bordeaux INP, CBMN, F-33600, Pessac, France
| | - Laurent Plawinski
- University of Bordeaux, CNRS UMR 5248, Bordeaux INP, CBMN, F-33600, Pessac, France
| | - Giovanna Muggiolu
- University of Bordeaux, CNRS UMR 5797, CENBG, F-33170, Gradignan, France
| | - Philippe Barberet
- University of Bordeaux, CNRS UMR 5797, CENBG, F-33170, Gradignan, France
| | - Marco Pereira
- University of Bordeaux, CNRS UMR 5218, IMS, F-33400, Talence, France
| | - Cédric Ayela
- University of Bordeaux, CNRS UMR 5218, IMS, F-33400, Talence, France
| | - Hervé Seznec
- University of Bordeaux, CNRS UMR 5797, CENBG, F-33170, Gradignan, France
| | | | - Jean-Marc Olive
- University of Bordeaux, CNRS UMR 5295, I2M, F-33400, Talence, France
| | - Bertrand Audoin
- University of Bordeaux, CNRS UMR 5295, I2M, F-33400, Talence, France.
| |
Collapse
|
13
|
Ma Y, Xu T, Huang X, Wang X, Li C, Jerwick J, Ning Y, Zeng X, Wang B, Wang Y, Zhang Z, Zhang X, Zhou C. Computer-Aided Diagnosis of Label-Free 3-D Optical Coherence Microscopy Images of Human Cervical Tissue. IEEE Trans Biomed Eng 2019; 66:2447-2456. [PMID: 30605087 PMCID: PMC6724217 DOI: 10.1109/tbme.2018.2890167] [Citation(s) in RCA: 16] [Impact Index Per Article: 3.2] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/17/2022]
Abstract
OBJECTIVE Ultrahigh-resolution optical coherence microscopy (OCM) has recently demonstrated its potential for accurate diagnosis of human cervical diseases. One major challenge for clinical adoption, however, is the steep learning curve clinicians need to overcome to interpret OCM images. Developing an intelligent technique for computer-aided diagnosis (CADx) to accurately interpret OCM images will facilitate clinical adoption of the technology and improve patient care. METHODS 497 high-resolution three-dimensional (3-D) OCM volumes (600 cross-sectional images each) were collected from 159 ex vivo specimens of 92 female patients. OCM image features were extracted using a convolutional neural network (CNN) model, concatenated with patient information [e.g., age and human papillomavirus (HPV) results], and classified using a support vector machine classifier. Ten-fold cross-validations were utilized to test the performance of the CADx method in a five-class classification task and a binary classification task. RESULTS An 88.3 ± 4.9% classification accuracy was achieved for five fine-grained classes of cervical tissue, namely normal, ectropion, low-grade and high-grade squamous intraepithelial lesions (LSIL and HSIL), and cancer. In the binary classification task [low-risk (normal, ectropion, and LSIL) versus high-risk (HSIL and cancer)], the CADx method achieved an area-under-the-curve value of 0.959 with an 86.7 ± 11.4% sensitivity and 93.5 ± 3.8% specificity. CONCLUSION The proposed deep-learning-based CADx method outperformed four human experts. It was also able to identify morphological characteristics in OCM images that were consistent with histopathological interpretations. SIGNIFICANCE Label-free OCM imaging, combined with deep-learning-based CADx methods, holds a great promise to be used in clinical settings for the effective screening and diagnosis of cervical diseases.
Collapse
|
14
|
Li J, Luo Y, Wang X, Wang N, Bo E, Chen S, Chen S, Chen S, Tsai MT, Liu L. Extending the depth of focus of fiber-optic optical coherence tomography using a chromatic dual-focus design. APPLIED OPTICS 2018; 57:6040-6046. [PMID: 30118032 DOI: 10.1364/ao.57.006040] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 02/01/2018] [Accepted: 06/21/2018] [Indexed: 06/08/2023]
Abstract
We report a dual-focus fiber-optic probe designed to extend depth of focus (DOF) in high-resolution endoscopic optical coherence tomography. We exploited the broad spectral bandwidth of a supercontinuum source and, in the fiber probe, the foci of the 750-1000 nm and 1100-1450 nm inputs were axially chromatically shifted. The interference signals from the two spectral bands were measured with a Si camera-based spectrometer and an InGaAs camera-based spectrometer, respectively. We verified the feasibility of the design using a phantom composed of microparticles and swine small intestine tissue ex vivo. The results showed that a transverse resolution below 5 μm over 300 μm could be maintained, and that the extended DOF was 2 times larger than that of the single focus probe via the use of dual spectral band inputs and a chromatic focal shift.
Collapse
|
15
|
Gao W, Wu X. Differences between time domain and Fourier domain optical coherence tomography in imaging tissues. J Microsc 2017; 268:119-128. [PMID: 28600827 DOI: 10.1111/jmi.12592] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/12/2016] [Revised: 05/16/2017] [Accepted: 05/17/2017] [Indexed: 12/21/2022]
Abstract
It has been numerously demonstrated that both time domain and Fourier domain optical coherence tomography (OCT) can generate high-resolution depth-resolved images of living tissues and cells. In this work, we compare the common points and differences between two methods when the continuous and random properties of live tissue are taken into account. It is found that when relationships that exist between the scattered light and tissue structures are taken into account, spectral interference measurements in Fourier domain OCT (FDOCT) is more advantageous than interference fringe envelope measurements in time domain OCT (TDOCT) in the cases where continuous property of tissue is taken into account. It is also demonstrated that when random property of tissue is taken into account FDOCT measures the Fourier transform of the spatial correlation function of the refractive index and speckle phenomena will limit the effective limiting imaging resolution in both TDOCT and FDOCT. Finally, the effective limiting resolution of both TDOCT and FDOCT are given which can be used to estimate the effective limiting resolution in various practical applications.
Collapse
Affiliation(s)
- W Gao
- Department of Optical Engineering, Nanjing University of Science and Technology, Nanjing, Jiangsu, P. R. China
| | - X Wu
- Department of Optical Engineering, Nanjing University of Science and Technology, Nanjing, Jiangsu, P. R. China
| |
Collapse
|
16
|
Bao W, Ding Z, Qiu J, Shen Y, Li P, Chen Z. Quasi-needle-like focus synthesized by optical coherence tomography. OPTICS LETTERS 2017; 42:1385-1388. [PMID: 28362775 DOI: 10.1364/ol.42.001385] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/07/2023]
Abstract
It is known that lateral resolution and depth of focus (DOF) in an optical imaging system are coupled, and a compromise between them has to be made. In this Letter, we propose to resolve the trade-off between lateral resolution and the DOF by a synthetic effective point spread function in optical path length (OPL) domain. A quasi-needle-like focus is synthesized by optical coherence tomography. We demonstrate that the synthesized quasi-needle-like focus provides a four-fold extension of a conventional DOF, while maintaining a high lateral resolution of 2.5 μm over a depth range of approximately 240 μm. The focal range can be further extended with more optical path length coded beams for synthesis involved.
Collapse
|
17
|
Lan G, Li G. Design of a k-space spectrometer for ultra-broad waveband spectral domain optical coherence tomography. Sci Rep 2017; 7:42353. [PMID: 28266502 PMCID: PMC5339709 DOI: 10.1038/srep42353] [Citation(s) in RCA: 34] [Impact Index Per Article: 4.9] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/13/2016] [Accepted: 01/08/2017] [Indexed: 11/09/2022] Open
Abstract
Nonlinear sampling of the interferograms in wavenumber (k) space degrades the depth-dependent signal sensitivity in conventional spectral domain optical coherence tomography (SD-OCT). Here we report a linear-in-wavenumber (k-space) spectrometer for an ultra-broad bandwidth (760 nm–920 nm) SD-OCT, whereby a combination of a grating and a prism serves as the dispersion group. Quantitative ray tracing is applied to optimize the linearity and minimize the optical path differences for the dispersed wavenumbers. Zemax simulation is used to fit the point spread functions to the rectangular shape of the pixels of the line-scan camera and to improve the pixel sampling rates. An experimental SD-OCT is built to test and compare the performance of the k-space spectrometer with that of a conventional one. Design results demonstrate that this k-space spectrometer can reduce the nonlinearity error in k-space from 14.86% to 0.47% (by approximately 30 times) compared to the conventional spectrometer. The 95% confidence interval for RMS diameters is 5.48 ± 1.76 μm—significantly smaller than both the pixel size (14 μm × 28 μm) and the Airy disc (25.82 μm in diameter, calculated at the wavenumber of 7.548 μm−1). Test results demonstrate that the fall-off curve from the k-space spectrometer exhibits much less decay (maximum as −5.20 dB) than the conventional spectrometer (maximum as –16.84 dB) over the whole imaging depth (2.2 mm).
Collapse
Affiliation(s)
- Gongpu Lan
- Visual and Biomedical Optics Lab, The Ohio State University, Columbus, OH 43212, USA.,Department of Ophthalmology and Visual Science, The Ohio State University, Columbus, OH 43212, USA.,Department of Electrical and Computer Engineering, The Ohio State University, Columbus, OH 43212, USA
| | - Guoqiang Li
- Visual and Biomedical Optics Lab, The Ohio State University, Columbus, OH 43212, USA.,Department of Ophthalmology and Visual Science, The Ohio State University, Columbus, OH 43212, USA.,Department of Electrical and Computer Engineering, The Ohio State University, Columbus, OH 43212, USA
| |
Collapse
|
18
|
Liu YZ, South FA, Xu Y, Carney PS, Boppart SA. Computational optical coherence tomography [Invited]. BIOMEDICAL OPTICS EXPRESS 2017; 8:1549-1574. [PMID: 28663849 PMCID: PMC5480564 DOI: 10.1364/boe.8.001549] [Citation(s) in RCA: 15] [Impact Index Per Article: 2.1] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 11/15/2016] [Revised: 02/09/2017] [Accepted: 02/10/2017] [Indexed: 05/18/2023]
Abstract
Optical coherence tomography (OCT) has become an important imaging modality with numerous biomedical applications. Challenges in high-speed, high-resolution, volumetric OCT imaging include managing dispersion, the trade-off between transverse resolution and depth-of-field, and correcting optical aberrations that are present in both the system and sample. Physics-based computational imaging techniques have proven to provide solutions to these limitations. This review aims to outline these computational imaging techniques within a general mathematical framework, summarize the historical progress, highlight the state-of-the-art achievements, and discuss the present challenges.
Collapse
Affiliation(s)
- Yuan-Zhi Liu
- Beckman Institute for Advanced Science and Technology, University of Illinois at Urbana-Champaign, USA
- Department of Electrical and Computer Engineering, University of Illinois at Urbana-Champaign, USA
| | - Fredrick A. South
- Beckman Institute for Advanced Science and Technology, University of Illinois at Urbana-Champaign, USA
- Department of Electrical and Computer Engineering, University of Illinois at Urbana-Champaign, USA
| | - Yang Xu
- Beckman Institute for Advanced Science and Technology, University of Illinois at Urbana-Champaign, USA
- Department of Electrical and Computer Engineering, University of Illinois at Urbana-Champaign, USA
| | - P. Scott Carney
- Beckman Institute for Advanced Science and Technology, University of Illinois at Urbana-Champaign, USA
- Department of Electrical and Computer Engineering, University of Illinois at Urbana-Champaign, USA
| | - Stephen A. Boppart
- Beckman Institute for Advanced Science and Technology, University of Illinois at Urbana-Champaign, USA
- Department of Electrical and Computer Engineering, University of Illinois at Urbana-Champaign, USA
- Departments of Bioengineering and Internal Medicine, University of Illinois at Urbana-Champaign, USA
| |
Collapse
|
19
|
Three-Dimensional Human Cardiac Tissue Engineered by Centrifugation of Stacked Cell Sheets and Cross-Sectional Observation of Its Synchronous Beatings by Optical Coherence Tomography. BIOMED RESEARCH INTERNATIONAL 2017; 2017:5341702. [PMID: 28326324 PMCID: PMC5343287 DOI: 10.1155/2017/5341702] [Citation(s) in RCA: 11] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 11/07/2016] [Revised: 12/29/2016] [Accepted: 02/06/2017] [Indexed: 01/23/2023]
Abstract
Three-dimensional (3D) tissues are engineered by stacking cell sheets, and these tissues have been applied in clinical regenerative therapies. The optimal fabrication technique of 3D human tissues and the real-time observation system for these tissues are important in tissue engineering, regenerative medicine, cardiac physiology, and the safety testing of candidate chemicals. In this study, for aiming the clinical application, 3D human cardiac tissues were rapidly fabricated by human induced pluripotent stem (iPS) cell-derived cardiac cell sheets with centrifugation, and the structures and beatings in the cardiac tissues were observed cross-sectionally and noninvasively by two optical coherence tomography (OCT) systems. The fabrication time was reduced to approximately one-quarter by centrifugation. The cross-sectional observation showed that multilayered cardiac cell sheets adhered tightly just after centrifugation. Additionally, the cross-sectional transmissions of beatings within multilayered human cardiac tissues were clearly detected by OCT. The observation showed the synchronous beatings of the thicker 3D human cardiac tissues, which were fabricated rapidly by cell sheet technology and centrifugation. The rapid tissue-fabrication technique and OCT technology will show a powerful potential in cardiac tissue engineering, regenerative medicine, and drug discovery research.
Collapse
|
20
|
Micro-optical coherence tomography of the mammalian cochlea. Sci Rep 2016; 6:33288. [PMID: 27633610 PMCID: PMC5025881 DOI: 10.1038/srep33288] [Citation(s) in RCA: 32] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/19/2016] [Accepted: 08/23/2016] [Indexed: 12/27/2022] Open
Abstract
The mammalian cochlea has historically resisted attempts at high-resolution, non-invasive imaging due to its small size, complex three-dimensional structure, and embedded location within the temporal bone. As a result, little is known about the relationship between an individual’s cochlear pathology and hearing function, and otologists must rely on physiological testing and imaging methods that offer limited resolution to obtain information about the inner ear prior to performing surgery. Micro-optical coherence tomography (μOCT) is a non-invasive, low-coherence interferometric imaging technique capable of resolving cellular-level anatomic structures. To determine whether μOCT is capable of resolving mammalian intracochlear anatomy, fixed guinea pig inner ears were imaged as whole temporal bones with cochlea in situ. Anatomical structures such as the tunnel of Corti, space of Nuel, modiolus, scalae, and cell groupings were visualized, in addition to individual cell types such as neuronal fibers, hair cells, and supporting cells. Visualization of these structures, via volumetrically-reconstructed image stacks and endoscopic perspective videos, represents an improvement over previous efforts using conventional OCT. These are the first μOCT images of mammalian cochlear anatomy, and they demonstrate μOCT’s potential utility as an imaging tool in otology research.
Collapse
|
21
|
Ohmi M, Wada Y. Dynamic analysis of mental sweating of eccrine sweat gland of human fingertip by time-sequential piled-up en face optical coherence tomography images. ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY. IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY. ANNUAL INTERNATIONAL CONFERENCE 2016; 2016:3918-3921. [PMID: 28269142 DOI: 10.1109/embc.2016.7591584] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/06/2023]
Abstract
In this paper, we demonstrate dynamic analysis of mental sweating for sound stimulus of a few tens of eccrine sweat glands by the time-sequential piled-up en face optical coherence tomography (OCT) images with the frame spacing of 3.3 sec. In the experiment, the amount of excess sweat can be evaluated simultaneously for a few tens of sweat glands by piling up of all the en face OCT images. Non-uniformity was observed in mental sweating where the amount of sweat in response to sound stimulus is different for each sweat gland. Furthermore, the amount of sweat is significantly increased in proportion to the strength of the stimulus.
Collapse
|
22
|
Luo W, Nguyen FT, Zysk AM, Ralston TS, Brockenbrough J, Marks DL, Oldenburg AL, Boppart SA. Optical Biopsy of Lymph Node Morphology using Optical Coherence Tomography. Technol Cancer Res Treat 2016; 4:539-48. [PMID: 16173824 DOI: 10.1177/153303460500400507] [Citation(s) in RCA: 63] [Impact Index Per Article: 7.9] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/17/2022] Open
Abstract
Optical diagnostic imaging techniques are increasingly being used in the clinical environment, allowing for improved screening and diagnosis while minimizing the number of invasive procedures. Diffuse optical tomography, for example, is capable of whole-breast imaging and is being developed as an alternative to traditional X-ray mammography. While this may eventually be a very effective screening method, other optical techniques are better suited for imaging on the cellular and molecular scale. Optical Coherence Tomography (OCT), for instance, is capable of high-resolution cross-sectional imaging of tissue morphology. In a manner analogous to ultrasound imaging except using optics, pulses of near-infrared light are sent into the tissue while coherence-gated reflections are measured interferometrically to form a cross-sectional image of tissue. In this paper we apply OCT techniques for the high-resolution three-dimensional visualization of lymph node morphology. We present the first reported OCT images showing detailed morphological structure and corresponding histological features of lymph nodes from a carcinogen-induced rat mammary tumor model, as well as from a human lymph node containing late stage metastatic disease. The results illustrate the potential for OCT to visualize detailed lymph node structures on the scale of micrometastases and the potential for the detection of metastatic nodal disease intraoperatively.
Collapse
Affiliation(s)
- Wei Luo
- University of Illinois at Urbana-Champaign, Beckman Institute for Advanced Science and Technology, 405 N. Mathews Ave., Urbana, IL 61801, USA
| | | | | | | | | | | | | | | |
Collapse
|
23
|
Celeng C, Takx RAP, Ferencik M, Maurovich-Horvat P. Non-invasive and invasive imaging of vulnerable coronary plaque. Trends Cardiovasc Med 2016; 26:538-47. [PMID: 27079893 DOI: 10.1016/j.tcm.2016.03.005] [Citation(s) in RCA: 23] [Impact Index Per Article: 2.9] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 12/12/2015] [Revised: 02/28/2016] [Accepted: 03/10/2016] [Indexed: 12/20/2022]
Abstract
Vulnerable plaque is characterized by a large necrotic core and an overlying thin fibrous cap. Non-invasive imaging modalities such as computed tomography angiography (CTA) and magnetic resonance imaging (MRI) allow for the assessment of morphological plaque characteristics, while positron emission tomography (PET) enables the detection of metabolic activity within the atherosclerotic lesions. Invasive imaging modalities such as intravascular ultrasound (IVUS), optical-coherence tomography (OCT), and intravascular MRI (IV-MRI) display plaques at a high spatial resolution. Near-infrared spectroscopy (NIRS) allows for the detection of chemical components of atherosclerotic plaques. In this review, we describe state-of-the-art non-invasive and invasive imaging modalities and stress the combination of their advantages to identify vulnerable plaque features.
Collapse
Affiliation(s)
- Csilla Celeng
- MTA-SE Cardiovascular Imaging Research Group, Heart and Vascular Center, Semmelweis University, Budapest, Hungary
| | - Richard A P Takx
- Cardiac MR PET CT Program, Division of Cardiovascular Imaging, Massachusetts General Hospital and Harvard Medical School, Boston, MA; Department of Radiology, University Medical Center Utrecht, Utrecht, The Netherlands
| | - Maros Ferencik
- Knight Cardiovascular Institute, Oregon Health and Science University, Portland, OR
| | - Pál Maurovich-Horvat
- MTA-SE Cardiovascular Imaging Research Group, Heart and Vascular Center, Semmelweis University, Budapest, Hungary.
| |
Collapse
|
24
|
Watanabe H, Rajagopalan UM, Nakamichi Y, Igarashi KM, Kadono H, Tanifuji M. Functional optical coherence tomography of rat olfactory bulb with periodic odor stimulation. BIOMEDICAL OPTICS EXPRESS 2016; 7:841-54. [PMID: 27231593 PMCID: PMC4866460 DOI: 10.1364/boe.7.000841] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 12/21/2015] [Revised: 02/07/2016] [Accepted: 02/08/2016] [Indexed: 05/30/2023]
Abstract
In rodent olfactory bulb (OB), optical intrinsic signal imaging (OISI) is commonly used to investigate functional maps to odorant stimulations. However, in such studies, the spatial resolution in depth direction (z-axis) is lost because of the integration of light from different depths. To solve this problem, we propose functional optical coherence tomography (fOCT) with periodic stimulation and continuous recording. In fOCT experiments of in vivo rat OB, propionic acid and m-cresol were used as odor stimulus presentations. Such a periodic stimulation enabled us to detect the specific odor-responses from highly scattering brain tissue. Swept source OCT operating at a wavelength of 1334 nm and a frequency of 20 kHz, was employed with theoretical depth and lateral resolutions of 6.7 μm and 15.4 μm, respectively. We succeeded in visualizing 2D cross sectional fOCT map across the neural layer structure of OCT in vivo. The detected fOCT signals corresponded to a few glomeruli of the medial and lateral parts of dorsal OB. We also obtained 3D fOCT maps, which upon integration across z-axis agreed well with OISI results. We expect such an approach to open a window for investigating and possibly addressing toward inter/intra-layer connections at high resolutions in the future.
Collapse
Affiliation(s)
- Hideyuki Watanabe
- Laboratory for Integrative Neural Systems, RIKEN Brain Science Institute, 2-1 Hirosawa, Wako-city, Saitama, 351-0198, Japan
- Course of Health Science, Graduate school of Medicine, Osaka University, 1-7 Yamada-oka, Suita, Osaka, 565-0871, Japan
| | - Uma Maheswari Rajagopalan
- Department of Food Life Sciences, Faculty of Food Life Sciences, Toyo University, 1-1-1 Izumino, Itakura-machi, Ora-gun, Gunma, 374-0193, Japan
| | - Yu Nakamichi
- Laboratory for Integrative Neural Systems, RIKEN Brain Science Institute, 2-1 Hirosawa, Wako-city, Saitama, 351-0198, Japan
| | - Kei M. Igarashi
- Department of Anatomy and Neurobiology School of Medicine University of California, Irvine Hall Room 112, California 92697, USA
| | - Hirofumi Kadono
- Graduate School of Science and Engineering, Saitama University, 255 Shimo-Okubo, Sakura-ku, Saitama-city, Saitama, 338-08570, Japan
| | - Manabu Tanifuji
- Laboratory for Integrative Neural Systems, RIKEN Brain Science Institute, 2-1 Hirosawa, Wako-city, Saitama, 351-0198, Japan
| |
Collapse
|
25
|
High Resolution Optical Coherence Tomography for Bio-Imaging. FRONTIERS IN BIOPHOTONICS FOR TRANSLATIONAL MEDICINE 2016. [DOI: 10.1007/978-981-287-627-0_6] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 01/28/2023]
|
26
|
Lee HS, Shin SW, Bae JK, Jung WG, Kim SW, Oak C, Chun BK, Ahn YC, Lee BJ, Lee KD. Preliminary study of optical coherence tomography imaging to identify microscopic extrathyroidal extension in patients with papillary thyroid carcinoma. Lasers Surg Med 2015; 48:371-6. [PMID: 26718751 DOI: 10.1002/lsm.22466] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Accepted: 12/14/2015] [Indexed: 11/10/2022]
Abstract
BACKGROUND AND OBJECTIVES We evaluated the feasibility of using optical coherence tomography (OCT), to identify microscopic extrathyroidal extension (mETE) in ex vivo thyroidectomy specimens of patients who underwent thyroidectomy for the treatment of papillary thyroid carcinoma (PTC). METHODS A total of 170 ex vivo OCT images of the tumor, were acquired just after completion of thyroidectomy in 17 patients. The OCT images of each patient were separately evaluated by two blinded investigators, and the outcomes were compared with the histopathology reports. RESULTS The sensitivity and specificity of mETE identification from the OCT images were 81.4% and 86.0%, respectively, for the first investigator, and 82.9% and 87.0%, respectively, for the second investigator. Substantial agreement between the investigators was verified by Cohen's κ (Cohen's κ = 0.772). CONCLUSION In this preliminary study of a limited series of ex vivo thyroidectomy specimens, we verified the feasibility of OCT as a method of identifying mETE in patients with PTC.
Collapse
Affiliation(s)
- Hyoung Shin Lee
- Department of Otolaryngology-Head and Neck Surgery, Kosin University College of Medicine, Busan, South Korea.,Innovative Biomedical Technology Research Center, College of Medicine, Kosin University, Busan, Korea
| | - Sung Won Shin
- Department of Biomedical Engineering, Ulsan National Institute of Science and Technology, Ulsan, Korea
| | - Jung Kweon Bae
- Department of Biomedical Engineering, Ulsan National Institute of Science and Technology, Ulsan, Korea
| | - Woong Gyu Jung
- Department of Biomedical Engineering, Ulsan National Institute of Science and Technology, Ulsan, Korea
| | - Sung Won Kim
- Department of Otolaryngology-Head and Neck Surgery, Kosin University College of Medicine, Busan, South Korea.,Innovative Biomedical Technology Research Center, College of Medicine, Kosin University, Busan, Korea
| | - Chulho Oak
- Innovative Biomedical Technology Research Center, College of Medicine, Kosin University, Busan, Korea.,Department of Internal Medicine, Kosin University College of Medicine, Busan, South Korea
| | - Bong Kwon Chun
- Department of Pathology, Kosin University College of Medicine, Busan, South Korea
| | - Yeh-Chan Ahn
- Innovative Biomedical Technology Research Center, College of Medicine, Kosin University, Busan, Korea.,Department of Biomedical Engineering and Center for Marine-Integrated Biomedical Technology, Pukyong National University, Busan, South Korea
| | - Byung-Joo Lee
- Department of Otorhinolaryngology-Head and Neck Surgery, Pusan National University School of Medicine and Medical Research Institute, Busan, South Korea
| | - Kang Dae Lee
- Department of Otolaryngology-Head and Neck Surgery, Kosin University College of Medicine, Busan, South Korea
| |
Collapse
|
27
|
South FA, Liu YZ, Xu Y, Shemonski ND, Carney PS, Boppart SA. Polarization-sensitive interferometric synthetic aperture microscopy. APPLIED PHYSICS LETTERS 2015; 107:211106. [PMID: 26648593 PMCID: PMC4662671 DOI: 10.1063/1.4936236] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 09/21/2015] [Accepted: 11/10/2015] [Indexed: 05/20/2023]
Abstract
Three-dimensional optical microscopy suffers from the well-known compromise between transverse resolution and depth-of-field. This is true for both structural imaging methods and their functional extensions. Interferometric synthetic aperture microscopy (ISAM) is a solution to the 3D coherent microscopy inverse problem that provides depth-independent transverse resolution. We demonstrate the extension of ISAM to polarization sensitive imaging, termed polarization-sensitive interferometric synthetic aperture microscopy (PS-ISAM). This technique is the first functionalization of the ISAM method and provides improved depth-of-field for polarization-sensitive imaging. The basic assumptions of polarization-sensitive imaging are explored, and refocusing of birefringent structures is experimentally demonstrated. PS-ISAM enables high-resolution volumetric imaging of birefringent materials and tissue.
Collapse
|
28
|
Hasegawa A, Haraguchi Y, Oikaze H, Kabetani Y, Sakaguchi K, Shimizu T. Optical coherence microscopy of living cells and bioengineered tissue dynamics in high-resolution cross-section. J Biomed Mater Res B Appl Biomater 2015; 105:481-488. [PMID: 26545952 DOI: 10.1002/jbm.b.33566] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/16/2015] [Revised: 09/25/2015] [Accepted: 10/21/2015] [Indexed: 01/22/2023]
Abstract
Optical coherence tomography (OCT) is a valuable tool in the cross-sectional observation/analysis of three-dimensional (3-D) biological tissues, and that histological observation is important clinically. However, the resolution of the technology is approximately 10-20 μm. In this study, optical coherence microscopy (OCM), a tomographic system combining OCT technology with a microscopic technique, was constructed for observing cells individually with a resolution at the submicrometer level. Cells and 3-D tissues fabricated by cell sheet technology were observed by OCM. Importantly, the cell nuclei and cytoplasm could be clearly distinguished, and the time-dependent dynamics of cell-sheet tissues could be observed in detail. Additionally, the 3-D migration of cells in the bioengineered tissue was also detected using OCM and metal-labeled cells. Bovine aortic endothelial cells, but not NIH3T3 murine embryonic skin fibroblasts, actively migrated within the 3-D tissues. This study showed that the OCM system would be a valuable tool in the fields of cell biology, tissue engineering, and regenerative medicine. © 2015 Wiley Periodicals, Inc. J Biomed Mater Res Part B: Appl Biomater, 105B: 481-488, 2017.
Collapse
Affiliation(s)
- Akiyuki Hasegawa
- Institute of Advanced Biomedical Engineering and Science, TWIns, Tokyo Women's Medical University, Tokyo, Japan
| | - Yuji Haraguchi
- Institute of Advanced Biomedical Engineering and Science, TWIns, Tokyo Women's Medical University, Tokyo, Japan
| | | | | | - Katsuhisa Sakaguchi
- Institute of Advanced Biomedical Engineering and Science, TWIns, Tokyo Women's Medical University, Tokyo, Japan.,School of Creative Science and Engineering, TWIns, Waseda University, 2-2 Wakamatsu-cho, Shinjuku-ku, Tokyo, 162-8480, Japan
| | - Tatsuya Shimizu
- Institute of Advanced Biomedical Engineering and Science, TWIns, Tokyo Women's Medical University, Tokyo, Japan
| |
Collapse
|
29
|
Zysk AM, Chen K, Gabrielson E, Tafra L, May Gonzalez EA, Canner JK, Schneider EB, Cittadine AJ, Carney PS, Boppart SA, Tsuchiya K, Sawyer K, Jacobs LK. Intraoperative Assessment of Final Margins with a Handheld Optical Imaging Probe During Breast-Conserving Surgery May Reduce the Reoperation Rate: Results of a Multicenter Study. Ann Surg Oncol 2015; 22. [PMID: 26202553 PMCID: PMC4839389 DOI: 10.1245/s10434-015-4665-2] [Citation(s) in RCA: 80] [Impact Index Per Article: 8.9] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/18/2022]
Abstract
BACKGROUND A multicenter, prospective, blinded study was performed to test the feasibility of using a handheld optical imaging probe for the intraoperative assessment of final surgical margins during breast-conserving surgery (BCS) and to determine the potential impact on patient outcomes. METHODS Forty-six patients with early-stage breast cancer (one with bilateral disease) undergoing BCS at two study sites, the Johns Hopkins Hospital and Anne Arundel Medical Center, were enrolled in this study. During BCS, cavity-shaved margins were obtained and the final margins were examined ex vivo in the operating room with a probe incorporating optical coherence tomography (OCT) hardware and interferometric synthetic aperture microscopy (ISAM) image processing. Images were interpreted after BCS by three physicians blinded to final pathology-reported margin status. Individual and combined interpretations were assessed. Results were compared to conventional postoperative histopathology. RESULTS A total of 2,191 images were collected and interpreted from 229 shave margin specimens. Of the eight patients (17 %) with positive margins (0 mm), which included invasive and in situ diseases, the device identified all positive margins in five (63%) of them; reoperation could potentially have been avoided in these patients. Among patients with pathologically negative margins (>0 mm), an estimated mean additional tissue volume of 10.7 ml (approximately 1% of overall breast volume) would have been unnecessarily removed due to false positives. CONCLUSIONS Intraoperative optical imaging of specimen margins with a handheld probe potentially eliminates the majority of reoperations.
Collapse
Affiliation(s)
| | - Kai Chen
- The Johns Hopkins Hospital, Baltimore, MD
- Sun Yat-sen Memorial Hospital, Guangzhou, Guangdong, People’s Republic of China
| | | | | | | | | | | | | | | | - Stephen A. Boppart
- Diagnostic Photonics, Inc., Chicago, IL
- University of Illinois at Urbana-Champaign, Urbana, IL
| | | | | | | |
Collapse
|
30
|
Deutsch B, Reddy R, Mayerich D, Bhargava R, Carney PS. Compositional prior information in computed infrared spectroscopic imaging. JOURNAL OF THE OPTICAL SOCIETY OF AMERICA. A, OPTICS, IMAGE SCIENCE, AND VISION 2015; 32:1126-1131. [PMID: 26367047 DOI: 10.1364/josaa.32.001126] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/05/2023]
Abstract
Compositional prior information is used to bridge a gap in the theory between optical coherence tomography (OCT), which provides high-resolution structural images by neglecting spectral variation, and imaging spectroscopy, which provides only spectral information without significant regard to structure. A constraint is proposed in which it is assumed that a sample is composed of N distinct materials with known spectra, allowing the structural and spectral composition of the sample to be determined with a number of measurements on the order of N. We present a forward model for a sample with heterogeneities along the optical axis and show through simulation that the N-species constraint allows unambiguous inversion of Fourier transform interferometric data within the spatial frequency passband of the optical system. We then explore the stability and limitations of this model and extend it to a general 3D heterogeneous sample.
Collapse
|
31
|
Cui D, Liu X, Zhang J, Yu X, Ding S, Luo Y, Gu J, Shum P, Liu L. Dual spectrometer system with spectral compounding for 1-μm optical coherence tomography in vivo. OPTICS LETTERS 2014; 39:6727-30. [PMID: 25490663 DOI: 10.1364/ol.39.006727] [Citation(s) in RCA: 10] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/05/2023]
Abstract
1 μm axial resolution spectral domain optical coherence tomography (OCT) is demonstrated for in vivo cellular resolution imaging. Output of two superluminescent diode sources is combined to provide near infrared illumination from 755 to 1105 nm. The spectral interference is detected using two spectrometers based on a Si camera and an InGaAs camera, respectively. Spectra from the two spectrometers are combined to achieve an axial resolution of 1.27 μm in air. Imaging was conducted on zebra fish larvae to visualize cellular details.
Collapse
|
32
|
Zhao Y, Marjanovic M, Chaney EJ, Graf BW, Mahmassani Z, Boppart MD, Boppart SA. Longitudinal label-free tracking of cell death dynamics in living engineered human skin tissue with a multimodal microscope. BIOMEDICAL OPTICS EXPRESS 2014; 5:3699-716. [PMID: 25360383 PMCID: PMC4206335 DOI: 10.1364/boe.5.003699] [Citation(s) in RCA: 9] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 07/09/2014] [Revised: 09/03/2014] [Accepted: 09/06/2014] [Indexed: 05/04/2023]
Abstract
We demonstrate real-time, longitudinal, label-free tracking of apoptotic and necrotic cells in living tissue using a multimodal microscope. The integrated imaging platform combines multi-photon microscopy (MPM, based on two-photon excitation fluorescence), optical coherence microscopy (OCM), and fluorescence lifetime imaging microscopy (FLIM). Three-dimensional (3-D) co-registered images are captured that carry comprehensive information of the sample, including structural, molecular, and metabolic properties, based on light scattering, autofluorescence intensity, and autofluorescence lifetime, respectively. Different cell death processes, namely, apoptosis and necrosis, of keratinocytes from different epidermal layers are longitudinally monitored and investigated. Differentiation of the two cell death processes in a complex living tissue environment is enabled by quantitative image analysis and high-confidence classification processing based on the multidimensional, cross-validating imaging data. These results suggest that despite the limitations of each individual label-free modality, this multimodal imaging approach holds the promise for studies of different cell death processes in living tissue and in vivo organs.
Collapse
Affiliation(s)
- Youbo Zhao
- Beckman Institute for Advanced Science and Technology, University of Illinois at Urbana-Champaign, Urbana, Illinois, USA
| | - Marina Marjanovic
- Beckman Institute for Advanced Science and Technology, University of Illinois at Urbana-Champaign, Urbana, Illinois, USA
| | - Eric J. Chaney
- Beckman Institute for Advanced Science and Technology, University of Illinois at Urbana-Champaign, Urbana, Illinois, USA
| | - Benedikt W. Graf
- Beckman Institute for Advanced Science and Technology, University of Illinois at Urbana-Champaign, Urbana, Illinois, USA
- Department of Electrical and Computer Engineering, University of Illinois at Urbana-Champaign, Urbana, Illinois, USA
| | - Ziad Mahmassani
- Beckman Institute for Advanced Science and Technology, University of Illinois at Urbana-Champaign, Urbana, Illinois, USA
- Department of Kinesiology and Community Health, University of Illinois at Urbana-Champaign, Urbana, Illinois, USA
| | - Marni D. Boppart
- Beckman Institute for Advanced Science and Technology, University of Illinois at Urbana-Champaign, Urbana, Illinois, USA
- Department of Kinesiology and Community Health, University of Illinois at Urbana-Champaign, Urbana, Illinois, USA
| | - Stephen A. Boppart
- Beckman Institute for Advanced Science and Technology, University of Illinois at Urbana-Champaign, Urbana, Illinois, USA
- Department of Electrical and Computer Engineering, University of Illinois at Urbana-Champaign, Urbana, Illinois, USA
- Department of Bioengineering, University of Illinois at Urbana-Champaign, Urbana, Illinois, USA
- Department of Internal Medicine, University of Illinois at Urbana-Champaign, Urbana, Illinois, USA
| |
Collapse
|
33
|
Liu YZ, Shemonski ND, Adie SG, Ahmad A, Bower AJ, Carney PS, Boppart SA. Computed optical interferometric tomography for high-speed volumetric cellular imaging. BIOMEDICAL OPTICS EXPRESS 2014; 5:2988-3000. [PMID: 25401012 PMCID: PMC4230871 DOI: 10.1364/boe.5.002988] [Citation(s) in RCA: 20] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 06/18/2014] [Revised: 08/05/2014] [Accepted: 08/06/2014] [Indexed: 05/18/2023]
Abstract
Three-dimensional high-resolution imaging methods are important for cellular-level research. Optical coherence microscopy (OCM) is a low-coherence-based interferometry technology for cellular imaging with both high axial and lateral resolution. Using a high-numerical-aperture objective, OCM normally has a shallow depth of field and requires scanning the focus through the entire region of interest to perform volumetric imaging. With a higher-numerical-aperture objective, the image quality of OCM is affected by and more sensitive to aberrations. Interferometric synthetic aperture microscopy (ISAM) and computational adaptive optics (CAO) are computed imaging techniques that overcome the depth-of-field limitation and the effect of optical aberrations in optical coherence tomography (OCT), respectively. In this work we combine OCM with ISAM and CAO to achieve high-speed volumetric cellular imaging. Experimental imaging results of ex vivo human breast tissue, ex vivo mouse brain tissue, in vitro fibroblast cells in 3D scaffolds, and in vivo human skin demonstrate the significant potential of this technique for high-speed volumetric cellular imaging.
Collapse
Affiliation(s)
- Yuan-Zhi Liu
- Beckman Institute for Advanced Science and Technology, University of Illinois at Urbana-Champaign, 405 North Mathews Avenue, Urbana, Illinois 61801, USA
- Department of Electrical and Computer Engineering, University of Illinois at Urbana-Champaign, 1406 West Green Street, Urbana, Illinois 61801, USA
| | - Nathan D. Shemonski
- Beckman Institute for Advanced Science and Technology, University of Illinois at Urbana-Champaign, 405 North Mathews Avenue, Urbana, Illinois 61801, USA
- Department of Electrical and Computer Engineering, University of Illinois at Urbana-Champaign, 1406 West Green Street, Urbana, Illinois 61801, USA
| | - Steven G. Adie
- Department of Biomedical Engineering, Cornell University, 101 Weill Hall, Ithaca, New York 14853, USA
| | - Adeel Ahmad
- Beckman Institute for Advanced Science and Technology, University of Illinois at Urbana-Champaign, 405 North Mathews Avenue, Urbana, Illinois 61801, USA
- Department of Electrical and Computer Engineering, University of Illinois at Urbana-Champaign, 1406 West Green Street, Urbana, Illinois 61801, USA
| | - Andrew J. Bower
- Beckman Institute for Advanced Science and Technology, University of Illinois at Urbana-Champaign, 405 North Mathews Avenue, Urbana, Illinois 61801, USA
- Department of Electrical and Computer Engineering, University of Illinois at Urbana-Champaign, 1406 West Green Street, Urbana, Illinois 61801, USA
| | - P. Scott Carney
- Beckman Institute for Advanced Science and Technology, University of Illinois at Urbana-Champaign, 405 North Mathews Avenue, Urbana, Illinois 61801, USA
- Department of Electrical and Computer Engineering, University of Illinois at Urbana-Champaign, 1406 West Green Street, Urbana, Illinois 61801, USA
| | - Stephen A. Boppart
- Beckman Institute for Advanced Science and Technology, University of Illinois at Urbana-Champaign, 405 North Mathews Avenue, Urbana, Illinois 61801, USA
- Department of Electrical and Computer Engineering, University of Illinois at Urbana-Champaign, 1406 West Green Street, Urbana, Illinois 61801, USA
- Departments of Bioengineering, University of Illinois at Urbana-Champaign, 1304 West Springfield Avenue, Urbana, Illinois 61801, USA
| |
Collapse
|
34
|
Xu Y, Chng XKB, Adie SG, Boppart SA, Scott Carney P. Multifocal interferometric synthetic aperture microscopy. OPTICS EXPRESS 2014; 22:16606-18. [PMID: 24977909 PMCID: PMC4162369 DOI: 10.1364/oe.22.016606] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 04/18/2014] [Revised: 06/16/2014] [Accepted: 06/17/2014] [Indexed: 05/22/2023]
Abstract
There is an inherent trade-off between transverse resolution and depth of field (DOF) in optical coherence tomography (OCT) which becomes a limiting factor for certain applications. Multifocal OCT and interferometric synthetic aperture microscopy (ISAM) each provide a distinct solution to the trade-off through modification to the experiment or via post-processing, respectively. In this paper, we have solved the inverse problem of multifocal OCT and present a general algorithm for combining multiple ISAM datasets. Multifocal ISAM (MISAM) uses a regularized combination of the resampled datasets to bring advantages of both multifocal OCT and ISAM to achieve optimal transverse resolution, extended effective DOF and improved signal-to-noise ratio. We present theory, simulation and experimental results.
Collapse
Affiliation(s)
- Yang Xu
- Beckman Institute for Advanced Science and Technology, University of Illinois at Urbana-Champaign, 405 N. Mathews Ave, Urbana, IL 61801,
USA
- Department of Electrical and Computer Engineering, University of Illinois at Urbana-Champaign, 1406 W. Green St, Urbana, IL 61801,
USA
| | - Xiong Kai Benjamin Chng
- Beckman Institute for Advanced Science and Technology, University of Illinois at Urbana-Champaign, 405 N. Mathews Ave, Urbana, IL 61801,
USA
- Department of Electrical and Computer Engineering, University of Illinois at Urbana-Champaign, 1406 W. Green St, Urbana, IL 61801,
USA
| | - Steven G. Adie
- Department of Biomedical Engineering, Cornell University, B61 Weill Hall, Ithaca, NY 14853,
USA
| | - Stephen A. Boppart
- Beckman Institute for Advanced Science and Technology, University of Illinois at Urbana-Champaign, 405 N. Mathews Ave, Urbana, IL 61801,
USA
- Department of Electrical and Computer Engineering, University of Illinois at Urbana-Champaign, 1406 W. Green St, Urbana, IL 61801,
USA
- Department of Bioengineering, University of Illinois at Urbana-Champaign, 1304 W. Springfield Avenue, Urbana, IL 61801,
USA
- Department of Internal Medicine, University of Illinois at Urbana-Champaign, 506 S. Mathews Ave, Urbana, IL 61801,
USA
| | - P. Scott Carney
- Beckman Institute for Advanced Science and Technology, University of Illinois at Urbana-Champaign, 405 N. Mathews Ave, Urbana, IL 61801,
USA
- Department of Electrical and Computer Engineering, University of Illinois at Urbana-Champaign, 1406 W. Green St, Urbana, IL 61801,
USA
| |
Collapse
|
35
|
Munley MT, Kagadis GC, McGee KP, Kirov AS, Jang S, Mutic S, Jeraj R, Xing L, Bourland JD. An introduction to molecular imaging in radiation oncology: a report by the AAPM Working Group on Molecular Imaging in Radiation Oncology (WGMIR). Med Phys 2014; 40:101501. [PMID: 24089890 DOI: 10.1118/1.4819818] [Citation(s) in RCA: 10] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/13/2022] Open
Abstract
Molecular imaging is the direct or indirect noninvasive monitoring and recording of the spatial and temporal distribution of in vivo molecular, genetic, and/or cellular processes for biochemical, biological, diagnostic, or therapeutic applications. Molecular images that indicate the presence of malignancy can be acquired using optical, ultrasonic, radiologic, radionuclide, and magnetic resonance techniques. For the radiation oncology physicist in particular, these methods and their roles in molecular imaging of oncologic processes are reviewed with respect to their physical bases and imaging characteristics, including signal intensity, spatial scale, and spatial resolution. Relevant molecular terminology is defined as an educational assist. Current and future clinical applications in oncologic diagnosis and treatment are discussed. National initiatives for the development of basic science and clinical molecular imaging techniques and expertise are reviewed, illustrating research opportunities in as well as the importance of this growing field.
Collapse
Affiliation(s)
- Michael T Munley
- Department of Radiation Oncology, Wake Forest School of Medicine, Winston-Salem, North Carolina 27157
| | | | | | | | | | | | | | | | | |
Collapse
|
36
|
Zendehnam A, Hosseinpour M, Mirzaei M, Hedayati K. Optimum values of air-filling fraction for photonic crystal fibers with different configurations and fixed number of air rings. APPLIED OPTICS 2014; 53:1075-1082. [PMID: 24663304 DOI: 10.1364/ao.53.001075] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 11/12/2013] [Accepted: 01/14/2014] [Indexed: 06/03/2023]
Abstract
In this study, a Gaussian amp function related to the Gaussian family is employed to approximate the output intensity profile of various arrangements of air holes in photonic crystal fibers (PCFs) with a fixed number of air rings (N=4). It is shown that d/Λ=0.5 can be the best minimum value of air-filling fraction for all of the studied PCFs when λ=1.35 μm, whereas, for λ=1.55 and 1.65 μm, d/Λ=0.6 is suitable for achieving the maximum output intensity with very low confinement loss.
Collapse
|
37
|
Ahmad A, Shemonski ND, Adie SG, Kim HS, Hwu WMW, Carney PS, Boppart SA. Real-time in vivo computed optical interferometric tomography. NATURE PHOTONICS 2013; 7:444-448. [PMID: 23956790 PMCID: PMC3742112 DOI: 10.1038/nphoton.2013.71] [Citation(s) in RCA: 32] [Impact Index Per Article: 2.9] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/20/2023]
Abstract
High-resolution real-time tomography of scattering tissues is important for many areas of medicine and biology1-6. However, the compromise between transverse resolution and depth-of-field in addition to low sensitivity deep in tissue continue to impede progress towards cellular-level volumetric tomography. Computed imaging has the potential to solve these long-standing limitations. Interferometric synthetic aperture microscopy (ISAM)7-9 is a computed imaging technique enabling high-resolution volumetric tomography with spatially invariant resolution. However, its potential for clinical diagnostics remains largely untapped since full volume reconstructions required lengthy postprocessing, and the phase-stability requirements have been difficult to satisfy in vivo. Here we demonstrate how 3-D Fourier-domain resampling, in combination with high-speed optical coherence tomography (OCT), can achieve high-resolution in vivo tomography. Enhanced depth sensitivity was achieved over a depth-of-field extended in real time by more than an order of magnitude. This work lays the foundation for high-speed volumetric cellular-level tomography.
Collapse
Affiliation(s)
- Adeel Ahmad
- Beckman Institute for Advanced Science and Technology, University of Illinois at Urbana-Champaign ; Department of Electrical and Computer Engineering, University of Illinois at Urbana-Champaign
| | | | | | | | | | | | | |
Collapse
|
38
|
Holmes C, Tabrizian M, Bagnaninchi PO. Motility imaging via optical coherence phase microscopy enables label-free monitoring of tissue growth and viability in 3D tissue-engineering scaffolds. J Tissue Eng Regen Med 2013; 9:641-5. [DOI: 10.1002/term.1687] [Citation(s) in RCA: 14] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/26/2012] [Revised: 09/10/2012] [Accepted: 11/23/2012] [Indexed: 11/11/2022]
Affiliation(s)
- Christina Holmes
- Department of Biomedical Engineering; McGill University; Montreal Canada
| | - Maryam Tabrizian
- Department of Biomedical Engineering; McGill University; Montreal Canada
- Faculty of Dentistry; McGill University; Montreal Canada
| | | |
Collapse
|
39
|
Liu M, Chou S, Chua C, Tay B, Ng B. The development of silk fibroin scaffolds using an indirect rapid prototyping approach: Morphological analysis and cell growth monitoring by spectral-domain optical coherence tomography. Med Eng Phys 2013; 35:253-62. [DOI: 10.1016/j.medengphy.2011.09.029] [Citation(s) in RCA: 20] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/16/2011] [Revised: 09/29/2011] [Accepted: 09/29/2011] [Indexed: 10/15/2022]
|
40
|
Longitudinal study of mammary epithelial and fibroblast co-cultures using optical coherence tomography reveals morphological hallmarks of pre-malignancy. PLoS One 2012; 7:e49148. [PMID: 23152864 PMCID: PMC3495770 DOI: 10.1371/journal.pone.0049148] [Citation(s) in RCA: 27] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/10/2012] [Accepted: 10/09/2012] [Indexed: 11/19/2022] Open
Abstract
The human mammary gland is a complex and heterogeneous organ, where the interactions between mammary epithelial cells (MEC) and stromal fibroblasts are known to regulate normal biology and tumorigenesis. We aimed to longitudinally evaluate morphology and size of organoids in 3D co-cultures of normal (MCF10A) or pre-malignant (MCF10DCIS.com) MEC and hTERT-immortalized fibroblasts from reduction mammoplasty (RMF). This co-culture model, based on an isogenic panel of cell lines, can yield insights to understand breast cancer progression. However, 3D cultures pose challenges for quantitative assessment and imaging, especially when the goal is to measure the same organoid structures over time. Using optical coherence tomography (OCT) as a non-invasive method to longitudinally quantify morphological changes, we found that OCT provides excellent visualization of MEC-fibroblast co-cultures as they form ductal acini and remodel over time. Different concentrations of fibroblasts and MEC reflecting reported physiological ratios [1] were evaluated, and we found that larger, hollower, and more aspherical acini were formed only by pre-malignant MEC (MCF10DCIS.com) in the presence of fibroblasts, whereas in comparable conditions, normal MEC (MCF10A) acini remained smaller and less aspherical. The ratio of fibroblast to MEC was also influential in determining organoid phenotypes, with higher concentrations of fibroblasts producing more aspherical structures in MCF10DCIS.com. These findings suggest that stromal-epithelial interactions between fibroblasts and MEC can be modeled in vitro, with OCT imaging as a convenient means of assaying time dependent changes, with the potential for yielding important biological insights about the differences between benign and pre-malignant cells.
Collapse
|
41
|
Tiernan JP, Ansari I, Hirst NA, Millner PA, Hughes TA, Jayne DG. Intra-operative tumour detection and staging in colorectal cancer surgery. Colorectal Dis 2012; 14:e510-20. [PMID: 22564278 DOI: 10.1111/j.1463-1318.2012.03078.x] [Citation(s) in RCA: 16] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 12/12/2022]
Abstract
AIM Surgical resection for colorectal cancer involves segmental resection and regional lymphadenectomy. The appropriateness of this 'one-size-fits-all' strategy is questioned as bowel cancer screening programmes result in a shift to earlier stage disease. Currently, the nodal status of a colorectal cancer can only be reliably determined by histopathological examination of the resected specimen. New methods of intra-operative staging are required to allow surgical resection to be tailored to the stage of the disease. METHOD A literature search was performed of PubMed and Embase databases using the terms 'colon' OR 'colorectal' AND 'intra-operative detection' OR 'intra-operative staging' OR 'intra-operative detection' OR 'radioimmunoguided surgery'. Articles published between January 1980 and January 2012 were included. Technologies that have the potential to allow intra-operative staging and treatment stratification were identified and further searches performed. RESULTS Established techniques such as sentinel lymph node mapping and radioimmunoguided surgery have benefited from combination with other technologies to allow real-time intra-operative staging. Intra-operative fluorescence, using naturally fluorescent biomarkers or fluorescent tumour probes, probably offers the most practical means of intra-operative lymph node staging and may be facilitated using nanotechnology. Optical coherence tomography and real-time elastography have the potential to provide an in vivo'virtual biopsy'. CONCLUSION Technological advances may allow accurate intra-operative lymph node staging to facilitate tailored surgical resection. This may become the next paradigm shift in colorectal cancer surgery.
Collapse
Affiliation(s)
- J P Tiernan
- Section of Translational Anaesthetic and Surgical Sciences, Leeds Institute of Molecular Medicine, St James's University Hospital, Leeds, UK.
| | | | | | | | | | | |
Collapse
|
42
|
Chen WL, Hu PS, Ghazaryan A, Chen SJ, Tsai TH, Dong CY. Quantitative analysis of multiphoton excitation autofluorescence and second harmonic generation imaging for medical diagnosis. Comput Med Imaging Graph 2012; 36:519-26. [PMID: 22824186 DOI: 10.1016/j.compmedimag.2012.06.003] [Citation(s) in RCA: 28] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/02/2012] [Revised: 06/05/2012] [Accepted: 06/15/2012] [Indexed: 11/26/2022]
Abstract
In recent years, two-photon excitation fluorescence and second harmonic generation microscopy has become an important tool in biomedical research. The ability of two-photon microscopy to achieve optical sectioning with minimal invasiveness is particularly advantageous for biomedical diagnosis. Advances in the miniaturization of the imaging system have increased its clinical potential, together with the development of quantitative technique for the analysis of data acquired using these imaging modalities. We present a review of the quantitative analysis techniques that have been used successfully with two-photon excitation fluorescence and SHG imaging. Specifically, quantification techniques using ratiometric, morphological, and structural differences to analyze two-photon images will be discussed, and their effectiveness at evaluating dermal and corneal pathologies and cancerous tumor growth will be described.
Collapse
Affiliation(s)
- Wei-Liang Chen
- Department of Physics, National Taiwan University, Taipei, Taiwan.
| | | | | | | | | | | |
Collapse
|
43
|
John R, Adie SG, Chaney EJ, Marjanovic M, Tangella KV, Boppart SA. Three-dimensional optical coherence tomography for optical biopsy of lymph nodes and assessment of metastatic disease. Ann Surg Oncol 2012; 20:3685-93. [PMID: 22688663 DOI: 10.1245/s10434-012-2434-z] [Citation(s) in RCA: 24] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/23/2011] [Indexed: 11/18/2022]
Abstract
BACKGROUND Numerous techniques have been developed for localizing lymph nodes before surgical resection and for their histological assessment. Nondestructive high-resolution transcapsule optical imaging of lymph nodes offers the potential for in situ assessment of metastatic involvement, potentially during surgical procedures. METHODS Three-dimensional optical coherence tomography (3-D OCT) was used for imaging and assessing resected popliteal lymph nodes from a preclinical rat metastatic tumor model over a 9-day time-course study after tumor induction. The spectral-domain OCT system utilized a center wavelength of 800 nm, provided axial and transverse resolutions of 3 and 12 μm, respectively, and performed imaging at 10,000 axial scans per second. RESULTS OCT is capable of providing high-resolution label-free images of intact lymph node microstructure based on intrinsic optical scattering properties with penetration depths of ~1-2 mm. The results demonstrate that OCT is capable of differentiating normal, reactive, and metastatic lymph nodes based on microstructural changes. The optical scattering and structural changes revealed by OCT from day 3 to day 9 after the injection of tumor cells into the lymphatic system correlate with inflammatory and immunological changes observed in the capsule, precortical regions, follicles, and germination centers found during histopathology. CONCLUSIONS We report for the first time a longitudinal study of 3-D transcapsule OCT imaging of intact lymph nodes demonstrating microstructural changes during metastatic infiltration. These results demonstrate the potential of OCT as a technique for intraoperative, real-time in situ 3-D optical biopsy of lymph nodes for the intraoperative staging of cancer.
Collapse
Affiliation(s)
- Renu John
- Beckman Institute for Advanced Science and Technology, University of Illinois at Urbana-Champaign, Urbana, IL, USA
| | | | | | | | | | | |
Collapse
|
44
|
Zhao Y, Graf BW, Chaney EJ, Mahmassani Z, Antoniadou E, DeVolder R, Kong H, Boppart MD, Boppart SA. Integrated multimodal optical microscopy for structural and functional imaging of engineered and natural skin. JOURNAL OF BIOPHOTONICS 2012; 5:437-48. [PMID: 22371330 PMCID: PMC4486208 DOI: 10.1002/jbio.201200003] [Citation(s) in RCA: 24] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 01/04/2012] [Revised: 02/07/2012] [Accepted: 02/07/2012] [Indexed: 05/21/2023]
Abstract
An integrated multimodal optical microscope is demonstrated for high-resolution, structural and functional imaging of engineered and natural skin. This microscope incorporates multiple imaging modalities including optical coherence (OCM), multi-photon (MPM), and fluorescence lifetime imaging microscopy (FLIM), enabling simultaneous visualization of multiple contrast sources and mechanisms from cells and tissues. Spatially co-registered OCM/MPM/FLIM images of multi-layered skin tissues are obtained, which are formed based on complementary information provided by different modalities, i.e., scattering information from OCM, molecular information from MPM, and functional cellular metabolism states from FLIM. Cellular structures in both the dermis and epidermis, especially different morphological and physiological states of keratinocytes from different epidermal layers, are revealed by mutually-validating images. In vivo imaging of human skin is also investigated, which demonstrates the potential of multimodal microscopy for in vivo investigation during engineered skin engraftment. This integrated imaging technique and microscope show the potential for investigating cellular dynamics in developing engineered skin and following in vivo grafting, which will help refine the control and culturing conditions necessary to obtain more robust and physiologically-relevant engineered skin substitutes.
Collapse
Affiliation(s)
- Youbo Zhao
- Biophotonics Imaging Laboratory, Beckman Institute for Advanced Science and Technology, University of Illinois at Urbana-Champaign, Urbana, IL 61801, USA
| | - Benedikt W. Graf
- Biophotonics Imaging Laboratory, Beckman Institute for Advanced Science and Technology, University of Illinois at Urbana-Champaign, Urbana, IL 61801, USA
- Department of Electrical and Computer Engineering, University of Illinois at Urbana-Champaign, Urbana, IL 61801, USA
| | - Eric J. Chaney
- Biophotonics Imaging Laboratory, Beckman Institute for Advanced Science and Technology, University of Illinois at Urbana-Champaign, Urbana, IL 61801, USA
| | - Ziad Mahmassani
- Department of Kinesiology and Community Health, University of Illinois at Urbana-Champaign, Urbana, IL 61801, USA
| | - Eleni Antoniadou
- Department of Bioengineering, University of Illinois at Urbana-Champaign, Urbana, IL 61801, USA
| | - Ross DeVolder
- Department of Chemical and Biomolecular Engineering, University of Illinois at Urbana-Champaign, Urbana, IL 61801, USA
| | - Hyunjoon Kong
- Department of Chemical and Biomolecular Engineering, University of Illinois at Urbana-Champaign, Urbana, IL 61801, USA
| | - Marni D. Boppart
- Department of Kinesiology and Community Health, University of Illinois at Urbana-Champaign, Urbana, IL 61801, USA
| | - Stephen A. Boppart
- Biophotonics Imaging Laboratory, Beckman Institute for Advanced Science and Technology, University of Illinois at Urbana-Champaign, Urbana, IL 61801, USA
- Department of Electrical and Computer Engineering, University of Illinois at Urbana-Champaign, Urbana, IL 61801, USA
- Department of Bioengineering, University of Illinois at Urbana-Champaign, Urbana, IL 61801, USA
- Department of Internal Medicine, University of Illinois at Urbana-Champaign, Urbana, IL 61801, USA
- Corresponding author: , Phone: +1 217 244 7479, Fax: +1 217 333 5833
| |
Collapse
|
45
|
Computational adaptive optics for broadband optical interferometric tomography of biological tissue. Proc Natl Acad Sci U S A 2012; 109:7175-80. [PMID: 22538815 DOI: 10.1073/pnas.1121193109] [Citation(s) in RCA: 134] [Impact Index Per Article: 11.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/18/2022] Open
Abstract
Aberrations in optical microscopy reduce image resolution and contrast, and can limit imaging depth when focusing into biological samples. Static correction of aberrations may be achieved through appropriate lens design, but this approach does not offer the flexibility of simultaneously correcting aberrations for all imaging depths, nor the adaptability to correct for sample-specific aberrations for high-quality tomographic optical imaging. Incorporation of adaptive optics (AO) methods have demonstrated considerable improvement in optical image contrast and resolution in noninterferometric microscopy techniques, as well as in optical coherence tomography. Here we present a method to correct aberrations in a tomogram rather than the beam of a broadband optical interferometry system. Based on Fourier optics principles, we correct aberrations of a virtual pupil using Zernike polynomials. When used in conjunction with the computed imaging method interferometric synthetic aperture microscopy, this computational AO enables object reconstruction (within the single scattering limit) with ideal focal-plane resolution at all depths. Tomographic reconstructions of tissue phantoms containing subresolution titanium-dioxide particles and of ex vivo rat lung tissue demonstrate aberration correction in datasets acquired with a highly astigmatic illumination beam. These results also demonstrate that imaging with an aberrated astigmatic beam provides the advantage of a more uniform depth-dependent signal compared to imaging with a standard gaussian beam. With further work, computational AO could enable the replacement of complicated and expensive optical hardware components with algorithms implemented on a standard desktop computer, making high-resolution 3D interferometric tomography accessible to a wider group of users and nonspecialists.
Collapse
|
46
|
Qin J, Reif R, Zhi Z, Dziennis S, Wang R. Hemodynamic and morphological vasculature response to a burn monitored using a combined dual-wavelength laser speckle and optical microangiography imaging system. BIOMEDICAL OPTICS EXPRESS 2012; 3:455-66. [PMID: 22435094 PMCID: PMC3296534 DOI: 10.1364/boe.3.000455] [Citation(s) in RCA: 8] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 11/10/2011] [Revised: 01/14/2012] [Accepted: 01/16/2012] [Indexed: 05/03/2023]
Abstract
A multi-functional imaging system capable of determining relative changes in blood flow, hemoglobin concentration, and morphological features of the blood vasculature is demonstrated. The system combines two non-invasive imaging techniques, a dual-wavelength laser speckle contrast imaging (2-LSI) and an optical microangiography (OMAG) system. 2-LSI is used to monitor the changes in the dynamic blood flow and the changes in the concentration of oxygenated (HbO), deoxygenated (Hb) and total hemoglobin (HbT). The OMAG system is used to acquire high resolution images of the functional blood vessel network. The vessel area density (VAD) is used to quantify the blood vessel network morphology, specifically the capillary recruitment. The proposed multi-functional system is employed to assess the blood perfusion status from a mouse pinna before and immediately after a burn injury. To our knowledge, this is the first non-invasive, non-contact and multifunctional imaging modality that can simultaneously measure variations of several blood perfusion parameters.
Collapse
Affiliation(s)
- Jia Qin
- Department of Bioengineering, University of Washington, 3720 15th Avenue NE, Seattle, Washington 98195, USA
- These authors contributed equally to this work
| | - Roberto Reif
- Department of Bioengineering, University of Washington, 3720 15th Avenue NE, Seattle, Washington 98195, USA
- These authors contributed equally to this work
| | - Zhongwei Zhi
- Department of Bioengineering, University of Washington, 3720 15th Avenue NE, Seattle, Washington 98195, USA
| | - Suzan Dziennis
- Department of Bioengineering, University of Washington, 3720 15th Avenue NE, Seattle, Washington 98195, USA
| | - Ruikang Wang
- Department of Bioengineering, University of Washington, 3720 15th Avenue NE, Seattle, Washington 98195, USA
| |
Collapse
|
47
|
Olivo M, Fu CY, Raghavan V, Lau WKO. New frontier in hypericin-mediated diagnosis of cancer with current optical technologies. Ann Biomed Eng 2011; 40:460-73. [PMID: 22124793 PMCID: PMC3281199 DOI: 10.1007/s10439-011-0462-7] [Citation(s) in RCA: 20] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/10/2011] [Accepted: 11/01/2011] [Indexed: 12/12/2022]
Abstract
Photosensitizers (PSs) have shown great potentials as molecular contrast agents in photodynamic diagnosis (PDD) of cancer. While the diagnostic values of PSs have been proven previously, little efforts have been put into developing optical imaging and diagnostic algorithms. In this article, we review the recent development of optical probes that have been used in conjunction with a potent PS, hypericin (HY). Various fluorescence techniques such as laser confocal microscopy, fluorescence urine cytology, endoscopy and endomicroscopy are covered. We will also discuss about image processing and classification approaches employed for accurate PDD. We anticipate that continual efforts in these developments could lead to an objective PDD and complete surgical clearance of tumors. Recent advancements in nanotechnology have also opened new horizons for PSs. The use of biocompatible gold nanoparticles as carrier for enhanced targeted delivery of HY has been attained. In addition, plasmonic properties of nanoparticles were harnessed to induce localized hyperthermia and to manage the release of PS molecules, enabling a better therapeutic outcome of a combined photodynamic and photothermal therapy. Finally, we discuss how nanoparticles can be used as contrast agents for other optical techniques such as optical coherence tomography and surface-enhanced Raman scattering imaging.
Collapse
Affiliation(s)
- Malini Olivo
- School of Physics, National University of Ireland, Galway, Ireland.
| | | | | | | |
Collapse
|
48
|
Watanabe H, Rajagopalan UM, Nakamichi Y, Igarashi KM, Madjarova VD, Kadono H, Tanifuji M. In vivo layer visualization of rat olfactory bulb by a swept source optical coherence tomography and its confirmation through electrocoagulation and anatomy. BIOMEDICAL OPTICS EXPRESS 2011; 2:2279-87. [PMID: 21833364 PMCID: PMC3149525 DOI: 10.1364/boe.2.002279] [Citation(s) in RCA: 8] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 06/06/2011] [Revised: 07/13/2011] [Accepted: 07/13/2011] [Indexed: 05/15/2023]
Abstract
Here, we report in vivo 3-D visualization of the layered organization of a rat olfactory bulb (OB) by a swept source optical coherence tomography (SS-OCT). The SS-OCT operates at a wavelength of 1334 nm with respective theoretical depth and lateral resolutions of 6.7 μm and 15.4 μm in air and hence it is possible to get a 3D structural map of OB in vivo at the micron level resolution with millimeter-scale imaging depth. Up until now, with methods such as MRI, confocal microscopy, OB depth structure in vivo had not been clearly visualized as these do not satisfy the criterion of simultaneously providing micron-scale spatial resolution and imaging up to a few millimeter in depth. In order to confirm the OB's layered organization revealed by SS-OCT, we introduced the technique of electrocoagulation to make landmarks across the layered structure. To our knowledge this is such a first study that combines electrocoagulation and OCT in vivo of rat OB. Our results confirmed the layered organization of OB, and moreover the layers were clearly identified by electrocoagulation landmarks both in the OCT structural and anatomical slice images. We expect such a combined study is beneficial for both OCT and neuroscience fields.
Collapse
Affiliation(s)
- Hideyuki Watanabe
- Graduate School of Science and Engineering, Saitama University, 255 Shimo-Okubo, Sakura-ku, Saitama-city, Saitama, 338-08570, Japan
- Laboratory for Integrative Neural Systems, RIKEN Brain Science Institute, 2-1 Hirosawa, Wako-city, Saitama, 351-0198, Japan
| | - Uma Maheswari Rajagopalan
- Laboratory for Integrative Neural Systems, RIKEN Brain Science Institute, 2-1 Hirosawa, Wako-city, Saitama, 351-0198, Japan
| | - Yu Nakamichi
- Laboratory for Integrative Neural Systems, RIKEN Brain Science Institute, 2-1 Hirosawa, Wako-city, Saitama, 351-0198, Japan
| | - Kei M. Igarashi
- Centre for the Biology of Memory, Medical-Technical Research Centre, Norwegian University of Science and Technology, Olav Ktrres gate 9, 7030 Trondheim, Norway
- Department of Physiology, Graduate of Medicine, University of Tokyo, 7-3-1 Hongo, Bunkyo-ku, Tokyo, 113-0033 Japan
- Laboratory for Integrative Neural Systems, RIKEN Brain Science Institute, 2-1 Hirosawa, Wako-city, Saitama, 351-0198, Japan
| | - Violeta Dimitrova Madjarova
- Graduate School of Science and Engineering, Saitama University, 255 Shimo-Okubo, Sakura-ku, Saitama-city, Saitama, 338-08570, Japan
| | - Hirofumi Kadono
- Graduate School of Science and Engineering, Saitama University, 255 Shimo-Okubo, Sakura-ku, Saitama-city, Saitama, 338-08570, Japan
| | - Manabu Tanifuji
- Laboratory for Integrative Neural Systems, RIKEN Brain Science Institute, 2-1 Hirosawa, Wako-city, Saitama, 351-0198, Japan
| |
Collapse
|
49
|
Bagnaninchi PO, Holmes C, Drummond N, Daoud J, Tabrizian M. Two-dimensional and three-dimensional viability measurements of adult stem cells with optical coherence phase microscopy. JOURNAL OF BIOMEDICAL OPTICS 2011; 16:086003. [PMID: 21895315 DOI: 10.1117/1.3606561] [Citation(s) in RCA: 11] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/31/2023]
Abstract
Cell viability assays are essential tools for cell biology. They assess healthy cells in a sample and enable the quantification of cellular responses to reagents of interest. Noninvasive and label-free assays are desirable in two-dimensional (2D) and three-dimensional (3D) cell culture to facilitate time-course viability studies. Cellular micromotion, emanating from cell to substrate distance variations, has been demonstrated as a marker of cell viability with electric cell-substrate impedance sensing (ECIS). In this study we investigated if optical coherence phase microscopy (OCPM) was able to report phase fluctuations of adult stem cells in 2D and 3D that could be associated with cellular micromotion. An OCPM has been developed around a Thorlabs engine (λo = 930 nm) and integrated in an inverted microscope with a custom scanning head. Human adipose derived stem cells (ADSCs, Invitrogen) were cultured in Mesenpro RS medium and seeded either on ECIS arrays, 2D cell culture dishes, or in 3D highly porous microplotted polymeric scaffolds. ADSC micromotion was confirmed by ECIS analysis. Live and fixed ADSCs were then investigated in 2D and 3D with OCPM. Significant differences were found in phase fluctuations between the different conditions. This study indicated that OCPM could potentially assess cell vitality in 2D and in 3D microstructures.
Collapse
Affiliation(s)
- Pierre O Bagnaninchi
- University of Edinburgh, MRC Centre for Regenerative Medicine, Edinburgh, United Kingdom.
| | | | | | | | | |
Collapse
|
50
|
Imaging the subcellular structure of human coronary atherosclerosis using micro-optical coherence tomography. Nat Med 2011; 17:1010-4. [PMID: 21743452 PMCID: PMC3151347 DOI: 10.1038/nm.2409] [Citation(s) in RCA: 350] [Impact Index Per Article: 26.9] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/28/2010] [Accepted: 02/10/2011] [Indexed: 01/30/2023]
Abstract
Progress in understanding, diagnosis, and treatment of coronary artery disease (CAD) has been hindered by our inability to observe cells and extracellular components associated with human coronary atherosclerosis in situ. The current standards for microstructural investigation, histology and electron microscopy, are destructive and prone to artifacts. The highest resolution intracoronary imaging modality, optical coherence tomography (OCT), has a resolution of ~10μm, which is too coarse for visualizing most cells. Here we report a new form of OCT, termed μOCT that has an order of magnitude improved resolution. We show that μOCT images of cadaver coronary arteries provide clear pictures of cellular and subcellular features associated with atherogenesis, thrombosis, and response to interventional therapy. These results suggest that μOCT can complement existing diagnostic techniques for investigating atherosclerotic specimens today and may in the future become a useful tool for cellular and subcellular characterization of the human coronary wall in vivo.
Collapse
|