1
|
Meng K, Zhu J, Zhang T, Zhang X, Zhang Y, Chen X, Li F, Tong Y, Zhang S, Qiu D, Yang H, Liu S, Yin L, Zhao R, Huang L, Li T, Gao M, Pan T, Yang J, Cheng H, Lin Y. Nanostructure-gated organic electrochemical transistors for accurate glucose monitoring in dynamic biological pH conditions. Biosens Bioelectron 2025; 287:117677. [PMID: 40513290 DOI: 10.1016/j.bios.2025.117677] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/08/2025] [Revised: 05/13/2025] [Accepted: 06/07/2025] [Indexed: 06/16/2025]
Abstract
Non-invasive, real-time, and continuous monitoring of trace amounts of glucose in near-neutral biofluids is significant for the daily care and treatment of diabetic patients or people with suboptimal health status. Despite improved sensing performance with novel low-dimensional materials or porous structures in various enzymatic and non-enzymatic electrochemical glucose sensors, they still suffer from high cost, poor long-term stability, and performance fluctuations in varied temperature and pH. This work synergistically combines an Au-modified porous laser-induced graphene (LIG) gate electrode with an organic electrochemical transistor (OECT) to create a flexible non-enzymatic glucose sensor. The resulting OECT-based non-enzymatic glucose sensor exhibits significantly enhanced sensitivity in near-neutral biofluids, the limit of detection (LOD) (0.08 μM in pH = 7.4), excellent stability over time (degradation of ∼10 % in 180 days) and against temperature changes (30 °C-40 °C), self-pH calibration capabilities, and uncompromised sensing performance with shrinking sizes. The highly consistent laser patterning technique and in situ galvanic reduction process for electrode modifications not only provide a simple yet versatile approach to creating low-cost, compact sensing platforms for precise and real-time sweat glucose measurements but also support scalable production, allowing the correlation study of key biomarkers in sweat and blood.
Collapse
Affiliation(s)
- Ke Meng
- School of Materials and Energy, University of Electronic Science and Technology of China, Chengdu, 610054, China
| | - Jia Zhu
- School of Materials and Energy, University of Electronic Science and Technology of China, Chengdu, 610054, China; Yangtze Delta Region Institute (Quzhou), University of Electronics Science and Technology of China, Quzhou, 324000, China.
| | - Tianyao Zhang
- School of Materials and Energy, University of Electronic Science and Technology of China, Chengdu, 610054, China
| | - Xianzhe Zhang
- Department of Engineering Science and Mechanics, The Pennsylvania State University, University Park, PA, 16802, USA
| | - Yingying Zhang
- Suzhou Institute of Biomedical Engineering and Technology, Chinese Academy of Science, Suzhou, 215011, China
| | - Xiangjie Chen
- School of Materials and Energy, University of Electronic Science and Technology of China, Chengdu, 610054, China
| | - Fan Li
- School of Materials and Energy, University of Electronic Science and Technology of China, Chengdu, 610054, China
| | - Yao Tong
- Suzhou Institute of Biomedical Engineering and Technology, Chinese Academy of Science, Suzhou, 215011, China
| | - Senhao Zhang
- Suzhou Institute of Biomedical Engineering and Technology, Chinese Academy of Science, Suzhou, 215011, China
| | - Donghai Qiu
- Suzhou Institute of Biomedical Engineering and Technology, Chinese Academy of Science, Suzhou, 215011, China
| | - Hongbo Yang
- Suzhou Institute of Biomedical Engineering and Technology, Chinese Academy of Science, Suzhou, 215011, China
| | - Shangbin Liu
- School of Materials Science and Engineering, Tsinghua University, Beijing, 100084, China
| | - Lan Yin
- School of Materials Science and Engineering, Tsinghua University, Beijing, 100084, China
| | - Rui Zhao
- Department of Gastroenterology, West China Hospital, Sichuan University, Chengdu, 610041, China
| | - Libin Huang
- Department of Gastroenterology, West China Hospital, Sichuan University, Chengdu, 610041, China
| | - Tao Li
- Department of Gastroenterology, West China Hospital, Sichuan University, Chengdu, 610041, China
| | - Min Gao
- School of Materials and Energy, University of Electronic Science and Technology of China, Chengdu, 610054, China
| | - Taisong Pan
- School of Materials and Energy, University of Electronic Science and Technology of China, Chengdu, 610054, China
| | - Jian Yang
- Research Center for Industries of the Future, Biomedical Engineering Program, School of Engineering, Westlake University, Hangzhou, Zhejiang, 310030, China
| | - Huanyu Cheng
- Department of Engineering Science and Mechanics, The Pennsylvania State University, University Park, PA, 16802, USA.
| | - Yuan Lin
- School of Materials and Energy, University of Electronic Science and Technology of China, Chengdu, 610054, China; Medico-Engineering Cooperation on Applied Medicine Research Center, University of Electronics Science and Technology of China, Chengdu, 610054, China.
| |
Collapse
|
2
|
Oliveira DA, Pola CC, Johnson ZT, Li J, Smith EA, McLamore ES, Vanegas DC, Claussen JC, Gomes CL. Laser-induced graphene with nickel oxide nanoparticles electrochemical immunosensor for rapid and label-free detection of Salmonella enterica Typhimurium. Mikrochim Acta 2025; 192:359. [PMID: 40381040 DOI: 10.1007/s00604-025-07197-8] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/02/2025] [Accepted: 04/27/2025] [Indexed: 05/19/2025]
Abstract
Cost-effectiveness, high-throughput capability, and scalable manufacturing are key features required for the fabrication of in-field electrochemical sensors applicable to food safety analysis. In this work, a two-step method is described to create laser-induced graphene electrodes decorated with nickel oxide nanoparticles (LIG-NiO). Fabrication of the LIG-NiO electrodes is performed via direct writing under ambient conditions using a polyimide sheet and nickel acetate solution as substrates, which is then converted into a label-free immunosensor for the detection of Salmonella enterica serovar Typhimurium by functionalizing the working surface with an anti-Salmonella antibody. The resulting electrochemical immunosensor exhibits a sensitivity of 3.93 ± 0.25 Ω (log (CFU mL-1)-1), a limit of detection (LOD) of 8 ± 3 CFU mL-1 and rapid response time (17 min) with a wide Salmonella Typhimurium linear sensing range, from 101 to 106 CFU mL-1 in buffer, covering relevant levels for food safety analysis without being affected by the presence of interferent bacteria Escherichia coli spp. Additionally, this LIG-NiO-based immunosensor presented a sensitivity of 1.92 ± 0.71 Ω (log (CFU mL-1)-1) when tested in chicken broth. The immunosensor developed in this study provides a simple fabrication method followed by functionalization and rapid Salmonella Typhimurium sensing that does not require sample pretreatment such as pre-enrichment or addition of external reagents, constituting a promising new sensing platform for pathogen detection in food safety monitoring and in general to other electrochemical immunosensing applications.
Collapse
Affiliation(s)
- Daniela A Oliveira
- Department of Biological and Agricultural Engineering, Texas A&M University, College Station, TX, 77843, USA
| | - Cicero C Pola
- Department of Food Science and Human Nutrition, Iowa State University, Ames, IA, 50011, USA
- Department of Mechanical Engineering, Iowa State University, Ames, IA, 50011, USA
| | - Zachary T Johnson
- Department of Mechanical Engineering, Iowa State University, Ames, IA, 50011, USA
| | - Jingzhe Li
- Department of Chemistry, Iowa State University, Ames, IA, 50011, USA
- US Department of Energy, Ames National Laboratory, Ames, IA, 50011, USA
| | - Emily A Smith
- Department of Chemistry, Iowa State University, Ames, IA, 50011, USA
- US Department of Energy, Ames National Laboratory, Ames, IA, 50011, USA
| | - Eric S McLamore
- Department of Agricultural Sciences, Clemson University, Clemson, SC, 29631, USA
| | - Diana C Vanegas
- Department of Environmental Engineering and Earth Sciences, Clemson University, Clemson, SC, 29631, USA
| | - Jonathan C Claussen
- Department of Mechanical Engineering, Iowa State University, Ames, IA, 50011, USA
| | - Carmen L Gomes
- Department of Mechanical Engineering, Iowa State University, Ames, IA, 50011, USA.
| |
Collapse
|
3
|
Kim T, Pak JJ. Fabrication and Characterization of a Flexible Non-Enzymatic Electrochemical Glucose Sensor Using a Cu Nanoparticle/Laser-Induced Graphene Fiber/Porous Laser-Induced Graphene Network Electrode. SENSORS (BASEL, SWITZERLAND) 2025; 25:2341. [PMID: 40218852 PMCID: PMC11991655 DOI: 10.3390/s25072341] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 02/14/2025] [Revised: 03/22/2025] [Accepted: 04/01/2025] [Indexed: 04/14/2025]
Abstract
We demonstrate a flexible electrochemical biosensor for non-enzymatic glucose detection under different bending conditions. The novel flexible glucose sensor consists of a Cu nanoparticle (NP)/laser-induced graphene fiber (LIGF)/porous laser-induced graphene (LIG) network structure on a polyimide film. The bare LIGF/LIG electrode fabricated using an 8.9 W laser power shows a measured sheet resistance and thickness of 6.8 Ω/□ and ~420 μm, respectively. In addition, a conventional Cu NP electroplating method is used to fabricate a Cu/LIGF/LIG electrode-based glucose sensor that shows excellent glucose detection characteristics, including a sensitivity of 1438.8 µA/mM∙cm2, a limit of detection (LOD) of 124 nM, and a broad linear range at an applied potential of +600 mV. Significantly, the Cu/LIGF/LIG electrode-based glucose sensor exhibits a relatively high sensitivity, low LOD, good linear detection range, and long-term stability at bending angles of 0°, 45°, 90°, 135°, and 180°.
Collapse
Affiliation(s)
| | - James Jungho Pak
- School of Electrical Engineering, Korea University, Seoul 136-713, Republic of Korea;
| |
Collapse
|
4
|
Massaglia G, Spisni G, Serra T, Quaglio M. Laser-Induced Graphene Electrodes for Flexible pH Sensors. NANOMATERIALS (BASEL, SWITZERLAND) 2024; 14:2008. [PMID: 39728544 PMCID: PMC11728752 DOI: 10.3390/nano14242008] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 10/30/2024] [Revised: 11/26/2024] [Accepted: 12/09/2024] [Indexed: 12/28/2024]
Abstract
In the growing field of personalized medicine, non-invasive wearable devices and sensors are valuable diagnostic tools for the real-time monitoring of physiological and biokinetic signals. Among all the possible multiple (bio)-entities, pH is important in defining health-related biological information, since its variations or alterations can be considered the cause or the effect of disease and disfunction within a biological system. In this work, an innovative (bio)-electrochemical flexible pH sensor was proposed by realizing three electrodes (working, reference, and counter) directly on a polyimide (Kapton) sheet through the implementation of CO2 laser writing, which locally converts the polymeric sheet into a laser-induced graphene material (LIG electrodes), preserving inherent mechanical flexibility of Kapton. A uniform distribution of nanostructured PEDOT:PSS was deposited via ultrasonic spray coating onto an LIG working electrode as the active material for pH sensing. With a pH-sensitive PEDOT coating, this flexible sensor showed good sensitivity defined through a linear Nernstian slope of (75.6 ± 9.1) mV/pH, across a pH range from 1 to 7. We demonstrated the capability to use this flexible pH sensor during dynamic experiments, and thus concluded that this device was suitable to guarantee an immediate response and good repeatability by measuring the same OCP values in correspondence with the same pH applied.
Collapse
Affiliation(s)
- Giulia Massaglia
- Department of Applied Science and Technology, Politecnico di Torino, Corso Duca Degli Abruzzi 24, 10129 Turin, Italy; (G.S.); (T.S.)
- Center for Sustainable Future Technologies, Istituto Italiano di Tecnologia, CSFT@Polito, Via Livorno 60, 10100 Turin, Italy
| | - Giacomo Spisni
- Department of Applied Science and Technology, Politecnico di Torino, Corso Duca Degli Abruzzi 24, 10129 Turin, Italy; (G.S.); (T.S.)
- Center for Sustainable Future Technologies, Istituto Italiano di Tecnologia, CSFT@Polito, Via Livorno 60, 10100 Turin, Italy
| | - Tommaso Serra
- Department of Applied Science and Technology, Politecnico di Torino, Corso Duca Degli Abruzzi 24, 10129 Turin, Italy; (G.S.); (T.S.)
| | - Marzia Quaglio
- Department of Applied Science and Technology, Politecnico di Torino, Corso Duca Degli Abruzzi 24, 10129 Turin, Italy; (G.S.); (T.S.)
| |
Collapse
|
5
|
Behrent A, Borggraefe V, Baeumner AJ. Laser-induced graphene trending in biosensors: understanding electrode shelf-life of this highly porous material. Anal Bioanal Chem 2024; 416:2097-2106. [PMID: 38082134 PMCID: PMC10950954 DOI: 10.1007/s00216-023-05082-y] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/03/2023] [Revised: 11/25/2023] [Accepted: 11/29/2023] [Indexed: 03/21/2024]
Abstract
Laser-induced graphene (LIG) has received much attention in recent years as a possible transducer material for electroanalytical sensors. Its simplicity of fabrication and good electrochemical performance are typically highlighted. However, we found that unmodified and untreated LIG electrodes had a limited shelf-life for certain electroanalytical applications, likely due to the adsorption of adventitious hydrocarbons from the storage environment. Electrode responses did not change immediately after exposure to ambient conditions but over longer periods of time, probably due to the immense specific surface area of the LIG material. LIG shelf-life is seldomly discussed prominently in the literature, yet overall trends for solutions to this challenge can be identified. Such findings from the literature regarding the long-term storage stability of LIG electrodes, pure and modified, are discussed here along with explanations for likely protective mechanisms. Specifically, applying a protective coating on LIG electrodes after manufacture is possibly the easiest method to preserve electrode functionality and should be identified as a trend for well-performing LIG electrodes in the future. Furthermore, suggested influences of the accompanying LIG microstructure/morphology on electrode characteristics are evaluated.
Collapse
Affiliation(s)
- Arne Behrent
- Institute of Analytical Chemistry, Chemo- and Biosensors, University of Regensburg, Universitätsstraße 31, 93053, Regensburg, Germany
| | - Veronika Borggraefe
- Institute of Analytical Chemistry, Chemo- and Biosensors, University of Regensburg, Universitätsstraße 31, 93053, Regensburg, Germany
| | - Antje J Baeumner
- Institute of Analytical Chemistry, Chemo- and Biosensors, University of Regensburg, Universitätsstraße 31, 93053, Regensburg, Germany.
| |
Collapse
|
6
|
Feng J, Jiang Y, Wang K, Li J, Zhang J, Tian M, Chen G, Hu L, Zhan Y, Qin Y. An Energy-Efficient Flexible Multi-Modal Wireless Sweat Sensing System Based on Laser Induced Graphene. SENSORS (BASEL, SWITZERLAND) 2023; 23:4818. [PMID: 37430732 DOI: 10.3390/s23104818] [Citation(s) in RCA: 2] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 03/30/2023] [Revised: 05/10/2023] [Accepted: 05/15/2023] [Indexed: 07/12/2023]
Abstract
Real-time sweat monitoring is vital for athletes in order to reflect their physical conditions, quantify their exercise loads, and evaluate their training results. Therefore, a multi-modal sweat sensing system with a patch-relay-host topology was developed, which consisted of a wireless sensor patch, a wireless data relay, and a host controller. The wireless sensor patch can monitor the lactate, glucose, K+, and Na+ concentrations in real-time. The data is forwarded via a wireless data relay through Near Field Communication (NFC) and Bluetooth Low Energy (BLE) technology and it is finally available on the host controller. Meanwhile, existing enzyme sensors in sweat-based wearable sports monitoring systems have limited sensitivities. To improve their sensitivities, this paper proposes a dual enzyme sensing optimization strategy and demonstrates Laser-Induced Graphene (LIG)-based sweat sensors decorated with Single-Walled Carbon Nanotubes (SWCNT). Manufacturing an entire LIG array takes less than one minute and costs about 0.11 yuan in materials, making it suitable for mass production. The in vitro test result showed sensitivities of 0.53 μA/mM and 3.9 μA/mM for lactate and glucose sensing, and 32.5 mV/decade and 33.2 mV/decade for K+ and Na+ sensing, respectively. To demonstrate the ability to characterize personal physical fitness, an ex vivo sweat analysis test was also performed. Overall, the high-sensitivity lactate enzyme sensor based on SWCNT/LIG can meet the requirements of sweat-based wearable sports monitoring systems.
Collapse
Affiliation(s)
- Jiuqing Feng
- School of Information Science and Technology, Fudan University, Shanghai 200433, China
| | - Yizhou Jiang
- School of Information Science and Technology, Fudan University, Shanghai 200433, China
| | - Kai Wang
- School of Information Science and Technology, Fudan University, Shanghai 200433, China
| | - Jianzheng Li
- School of Information Science and Technology, Fudan University, Shanghai 200433, China
| | - Jialong Zhang
- School of Information Science and Technology, Fudan University, Shanghai 200433, China
| | - Mi Tian
- Huashan Hospital, Shanghai 200040, China
| | - Guoping Chen
- School of Information Science and Technology, Fudan University, Shanghai 200433, China
| | - Laigui Hu
- School of Information Science and Technology, Fudan University, Shanghai 200433, China
| | - Yiqiang Zhan
- School of Information Science and Technology, Fudan University, Shanghai 200433, China
| | - Yajie Qin
- School of Information Science and Technology, Fudan University, Shanghai 200433, China
| |
Collapse
|
7
|
Koukouviti E, Soulis D, Economou A, Kokkinos C. Wooden Tongue Depressor Multiplex Saliva Biosensor Fabricated via Diode Laser Engraving. Anal Chem 2023; 95:6765-6768. [PMID: 37079776 DOI: 10.1021/acs.analchem.3c01211] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 04/22/2023]
Abstract
Since wood is a renewable, biodegradable naturally occurring material, the development of conductive patterns on wood substrates is a new and innovative chapter in sustainable electronics and sensors. Herein, we describe the first wooden (bio)sensing device fabricated via diode laser-induced graphitization. For this purpose, a wooden tongue depressor (WTD) is laser-treated and converted to an electrochemical multiplex biosensing device for oral fluid analysis. A low-cost laser engraver, equipped with a low-power (0.5 W) diode laser, programmably irradiates the surface of the WTD, forming two mini electrochemical cells (e-cells). The two e-cells consist of four graphite electrodes: two working electrodes, a common counter, and a common reference electrode. The two e-cells are spatially separated via programmable pen-plotting, using a commercial hydrophobic marker pen. Proof-of-principle for biosensing is demonstrated for the simultaneous determination of glucose and nitrite in artificial saliva. This wooden electrochemical biodevice is an easy-to-fabricate disposable point-of-care chip with a wide scope of applicability to other bioassays, while it paves the way for the low-cost and straightforward production of wooden electrochemical platforms.
Collapse
Affiliation(s)
- Eleni Koukouviti
- Laboratory of Analytical Chemistry, Department of Chemistry, National and Kapodistrian University of Athens, Athens, 157 71, Greece
| | - Dionysios Soulis
- Laboratory of Analytical Chemistry, Department of Chemistry, National and Kapodistrian University of Athens, Athens, 157 71, Greece
| | - Anastasios Economou
- Laboratory of Analytical Chemistry, Department of Chemistry, National and Kapodistrian University of Athens, Athens, 157 71, Greece
| | - Christos Kokkinos
- Laboratory of Analytical Chemistry, Department of Chemistry, National and Kapodistrian University of Athens, Athens, 157 71, Greece
| |
Collapse
|
8
|
Wanjari VP, Reddy AS, Duttagupta SP, Singh SP. Laser-induced graphene-based electrochemical biosensors for environmental applications: a perspective. ENVIRONMENTAL SCIENCE AND POLLUTION RESEARCH INTERNATIONAL 2023; 30:42643-42657. [PMID: 35622288 DOI: 10.1007/s11356-022-21035-x] [Citation(s) in RCA: 12] [Impact Index Per Article: 6.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 02/18/2022] [Accepted: 05/19/2022] [Indexed: 06/15/2023]
Abstract
Biosensors are miniaturized devices that provide the advantage of in situ and point-of-care monitoring of analytes of interest. Electrochemical biosensors use the mechanism of oxidation-reduction reactions and measurement of corresponding electron transfer as changes in current, voltage, or other parameters using different electrochemical techniques. The use of electrochemically active materials is critical for the effective functioning of electrochemical biosensors. Laser-induced graphene (LIG) has garnered increasing interest in biosensor development and improvement due to its high electrical conductivity, specific surface area, and simple and scalable fabrication process. The effort of this perspective is to understand the existing classes of analytes and the mechanisms of their detection using LIG-based biosensors. The manuscript has highlighted the potential use of LIG, its modifications, and its use with various receptors for sensing various environmental pollutants. Although the conventional graphene-based sensors effectively detect trace levels for many analytes in different applications, the chemical and energy-intensive fabrication and time-consuming processes make it imperative to explore a low-cost and scalable option such as LIG for biosensors production. The focus of these potential biosensors has been kept on detection analytes of environmental significance such as heavy metals ions, organic and inorganic compounds, fertilizers, pesticides, pathogens, and antibiotics. The use of LIG directly as an electrode, its modifications with nanomaterials and polymers, and its combination with bioreceptors such as aptamers and polymers has been summarized. The strengths, weaknesses, opportunities, and threats analysis has also been done to understand the viability of incorporating LIG-based electrochemical biosensors for environmental applications.
Collapse
Affiliation(s)
- Vikram P Wanjari
- Centre for Research in Nanotechnology and Science, IIT Bombay, Mumbai, India
| | - A Sudharshan Reddy
- Environmental Science and Engineering Department, IIT Bombay, Mumbai, India
| | - Siddhartha P Duttagupta
- Centre for Research in Nanotechnology and Science, IIT Bombay, Mumbai, India
- Department of Electrical Engineering, IIT Bombay, Mumbai, India
| | - Swatantra P Singh
- Centre for Research in Nanotechnology and Science, IIT Bombay, Mumbai, India.
- Environmental Science and Engineering Department, IIT Bombay, Mumbai, India.
- Interdisciplinary Program in Climate Studies, IIT Bombay, Mumbai, India.
| |
Collapse
|
9
|
Yudasari N, Hardiansyah A, Herbani Y, Isnaeni, Suliyanti MM, Djuhana D. Single-step laser ablation synthesis of ZnO–Ag nanocomposites for broad-spectrum dye photodegradation and bacterial photoinactivation. J Photochem Photobiol A Chem 2023. [DOI: 10.1016/j.jphotochem.2023.114717] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 03/29/2023]
|
10
|
Zhang R, Jiang J, Wu W. Wearable chemical sensors based on 2D materials for healthcare applications. NANOSCALE 2023; 15:3079-3105. [PMID: 36723394 DOI: 10.1039/d2nr05447g] [Citation(s) in RCA: 4] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/18/2023]
Abstract
Chemical sensors worn on the body could make possible the continuous, noninvasive, and accurate monitoring of vital human signals, which is necessary for remote health monitoring and telemedicine. Attractive for creating high-performance, wearable chemical sensors are atomically thin materials with intriguing physical features, abundant chemistry, and high surface-to-volume ratios. These advantages allow for appropriate material-analyte interactions, resulting in a high level of sensitivity even at trace analyte concentrations. Previous review articles covered the material and device elements of 2D material-based wearable devices extensively. In contrast, little research has addressed the existing state, future outlook, and promise of 2D materials for wearable chemical sensors. We provide an overview of recent advances in 2D-material-based wearable chemical sensors to overcome this deficiency. The structure design, manufacturing techniques, and mechanisms of 2D material-based wearable chemical sensors will be evaluated, as well as their applicability in human health monitoring. Importantly, we present a thorough review of the current state of the art and the technological gaps that would enable the future design and nanomanufacturing of 2D materials and wearable chemical sensors. Finally, we explore the challenges and opportunities associated with designing and implementing 2D wearable chemical sensors.
Collapse
Affiliation(s)
- Ruifang Zhang
- School of Industrial Engineering, Purdue University, West Lafayette, Indiana 47907, USA.
- Flex Laboratory, Purdue University, West Lafayette, Indiana 47907, USA
| | - Jing Jiang
- School of Industrial Engineering, Purdue University, West Lafayette, Indiana 47907, USA.
- Flex Laboratory, Purdue University, West Lafayette, Indiana 47907, USA
| | - Wenzhuo Wu
- School of Industrial Engineering, Purdue University, West Lafayette, Indiana 47907, USA.
- Flex Laboratory, Purdue University, West Lafayette, Indiana 47907, USA
- Regenstrief Center for Healthcare Engineering, Purdue University, West Lafayette, Indiana 47907, USA
- The Center for Education and Research in Information Assurance and Security (CERIAS), Purdue University, West Lafayette, IN 47907, USA
- Birck Nanotechnology Center, Purdue University, West Lafayette, IN 47907, USA
| |
Collapse
|
11
|
Cardoso RM, Pereira TS, Santos DMD, Migliorini FL, Mattoso LH, Correa DS. Laser-induced graphitized electrodes enabled by a 3D printer/diode laser setup for voltammetric detection of hormones. Electrochim Acta 2023. [DOI: 10.1016/j.electacta.2023.141874] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/11/2023]
|
12
|
Goel S, Amreen K. Laser induced graphanized microfluidic devices. BIOMICROFLUIDICS 2022; 16:061505. [PMID: 36483020 PMCID: PMC9726225 DOI: 10.1063/5.0111867] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 07/20/2022] [Accepted: 11/16/2022] [Indexed: 06/17/2023]
Abstract
With the advent of cyber-physical system-based automation and intelligence, the development of flexible and wearable devices has dramatically enhanced. Evidently, this has led to the thrust to realize standalone and sufficiently-self-powered miniaturized devices for a variety of sensing and monitoring applications. To this end, a range of aspects needs to be carefully and synergistically optimized. These include the choice of material, micro-reservoir to suitably place the analytes, integrable electrodes, detection mechanism, microprocessor/microcontroller architecture, signal-processing, software, etc. In this context, several researchers are working toward developing novel flexible devices having a micro-reservoir, both in flow-through and stationary phases, integrated with graphanized zones created by simple benchtop lasers. Various substrates, like different kinds of cloths, papers, and polymers, have been harnessed to develop laser-ablated graphene regions along with a micro-reservoir to aptly place various analytes to be sensed/monitored. Likewise, similar substrates have been utilized for energy harvesting by fuel cell or solar routes and supercapacitor-based energy storage. Overall, realization of a prototype is envisioned by integrating various sub-systems, including sensory, energy harvesting, energy storage, and IoT sub-systems, on a single mini-platform. In this work, the diversified work toward developing such prototypes will be showcased and current and future commercialization potential will be projected.
Collapse
Affiliation(s)
- Sanket Goel
- MEMS, Microfluidics and Nanoelectronics (MMNE) Lab, Birla Institute of Technology and Science (BITS) Pilani, Hyderabad Campus, Hyderabad 500078, India
| | - Khairunnisa Amreen
- MEMS, Microfluidics and Nanoelectronics (MMNE) Lab, Birla Institute of Technology and Science (BITS) Pilani, Hyderabad Campus, Hyderabad 500078, India
| |
Collapse
|
13
|
Izhar F, Imran M, Izhar H, Latif S, Hussain N, Iqbal HMN, Bilal M. Recent advances in metal-based nanoporous materials for sensing environmentally-related biomolecules. CHEMOSPHERE 2022; 307:135999. [PMID: 35985388 DOI: 10.1016/j.chemosphere.2022.135999] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 05/11/2022] [Revised: 07/11/2022] [Accepted: 08/07/2022] [Indexed: 06/15/2023]
Abstract
Highly sensitive, stable, selective, efficient, and short reaction time sensors play a substantial role in daily life/industry and are the need of the day. Due to the rising environmental issues, nanoporous carbon and metal-based materials have attracted significant attention in environmental analysis owing to their intriguing and multifunctional properties and cost-effective and rapid detection of different analytes by sensing applications. Environmental-related issues such as pollution have been a significant threat to the world. Therefore, it is necessary to fabricate highly promising performance-based sensor materials with excellent reliability, selectivity and good sensitivity for monitoring various analytes. In this regard, different methods have been employed to fabricate these sensors comprising metal, metal oxides, metal oxide carbon composites and MOFs leading to the formation of nanoporous metal and carbon composites. These composites have exceptional properties such as large surface area, distinctive porosity, and high conductivity, making them promising candidates for several versatile sensing applications. This review covers recent advances and significant studies in the sensing field of various nanoporous metal and carbon composites. Key challenges and future opportunities in this exciting field are also part of this review.
Collapse
Affiliation(s)
- Fatima Izhar
- Centre for Inorganic Chemistry, School of Chemistry, University of the Punjab, Lahore, Pakistan
| | - Muhammad Imran
- Centre for Inorganic Chemistry, School of Chemistry, University of the Punjab, Lahore, Pakistan.
| | - Hamyal Izhar
- Centre for Inorganic Chemistry, School of Chemistry, University of the Punjab, Lahore, Pakistan
| | - Shoomaila Latif
- School of Physical Sciences, University of the Punjab, Lahore, 53700, Pakistan
| | - Nazim Hussain
- Centre for Applied Molecular Biology (CAMB), University of the Punjab, Lahore, 53700, Pakistan
| | - Hafiz M N Iqbal
- Tecnologico de Monterrey, School of Engineering and Sciences, Monterrey, 64849, Mexico
| | - Muhammad Bilal
- School of Life Science and Food Engineering, Huaiyin Institute of Technology, Huaian, 223003, China.
| |
Collapse
|
14
|
Singh A, Ahmed A, Sharma A, Arya S. Graphene and Its Derivatives: Synthesis and Application in the Electrochemical Detection of Analytes in Sweat. BIOSENSORS 2022; 12:910. [PMID: 36291046 PMCID: PMC9599499 DOI: 10.3390/bios12100910] [Citation(s) in RCA: 10] [Impact Index Per Article: 3.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 09/12/2022] [Revised: 10/07/2022] [Accepted: 10/15/2022] [Indexed: 05/25/2023]
Abstract
Wearable sensors and invasive devices have been studied extensively in recent years as the demand for real-time human healthcare applications and seamless human-machine interaction has risen exponentially. An explosion in sensor research throughout the globe has been ignited by the unique features such as thermal, electrical, and mechanical properties of graphene. This includes wearable sensors and implants, which can detect a wide range of data, including body temperature, pulse oxygenation, blood pressure, glucose, and the other analytes present in sweat. Graphene-based sensors for real-time human health monitoring are also being developed. This review is a comprehensive discussion about the properties of graphene, routes to its synthesis, derivatives of graphene, etc. Moreover, the basic features of a biosensor along with the chemistry of sweat are also discussed in detail. The review mainly focusses on the graphene and its derivative-based wearable sensors for the detection of analytes in sweat. Graphene-based sensors for health monitoring will be examined and explained in this study as an overview of the most current innovations in sensor designs, sensing processes, technological advancements, sensor system components, and potential hurdles. The future holds great opportunities for the development of efficient and advanced graphene-based sensors for the detection of analytes in sweat.
Collapse
Affiliation(s)
| | | | | | - Sandeep Arya
- Department of Physics, University of Jammu, Jammu 180006, India
| |
Collapse
|
15
|
Amouzadeh Tabrizi M, Acedo P. An electrochemical membrane-based aptasensor for detection of severe acute respiratory syndrome coronavirus-2 receptor-binding domain. APPLIED SURFACE SCIENCE 2022; 598:153867. [PMID: 35669218 PMCID: PMC9158412 DOI: 10.1016/j.apsusc.2022.153867] [Citation(s) in RCA: 11] [Impact Index Per Article: 3.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 05/05/2022] [Revised: 05/29/2022] [Accepted: 05/29/2022] [Indexed: 05/11/2023]
Abstract
Herein, we report an electrochemical membrane-based aptasensor for the determination of the SARS-CoV-2 receptor-binding domain (SARS-CoV-2-RBD). For this purpose, the nanoporous anodic aluminium oxide membrane (NPAOM) was first fabricated electrochemically. The NPAOM was then functionalized with 3-mercaptopropyl trimethoxysilane (NPAOM-Si-SH). After that, the NPAOM-Si-SH was decorated with gold nanoparticles by using gold ion and sodium borohydride. The NPAOM-Si-S-Aunano was then attached to the surface of the working electrode of a laser-engraved graphene electrode (LEGE). Subsequently, the LEGE/NPAOM-Si-S-Aunano was fixed inside a flow cell that was made by using a three-dimensional (3D) printer, and then thiolated aptamer was transferred into the flow cell using a pump. The electrochemical behavior of the LEGE/NPAOM-Si-S-Aunano-Aptamer was studied using square wave voltammetry (SWV) in the presence of potassium ferrocyanide as a redox probe. The response of the LEGE/NPAOM-Si-S-Aunano-Aptamer to the different concentrations of the SARS-CoV-2-RBD in human saliva sample was investigated in the concentration range of 2.5-40.0 ng/mL. The limit of the detection was found to be 0.8 ng/mL. The LEGE/NPAOM-Si-S-Aunano-Aptamer showed good selectivity to 5.0 ng/mL of SARS-CoV-2-RBD in the presence of five times of the interfering agents like hemagglutinin and neuraminidase as the influenza A virus major surface glycoproteins.
Collapse
Affiliation(s)
| | - Pablo Acedo
- Electronic Technology Department, Universidad Carlos III de Madrid, Leganés, Spain
| |
Collapse
|
16
|
An Electrochemical Immunosensor for the Determination of Procalcitonin Using the Gold-Graphene Interdigitated Electrode. BIOSENSORS 2022; 12:bios12100771. [PMID: 36290909 PMCID: PMC9599768 DOI: 10.3390/bios12100771] [Citation(s) in RCA: 6] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 09/06/2022] [Revised: 09/16/2022] [Accepted: 09/17/2022] [Indexed: 01/09/2023]
Abstract
Procalcitonin (PCT) is considered a sepsis and infection biomarker. Herein, an interdigitated electrochemical immunosensor for the determination of PCT has been developed. The interdigitated electrode was made of the laser-engraved graphene electrode decorated with gold (LEGE/Aunano). The scanning electron microscopy indicated the LEGE/Aunano has been fabricated successfully. After that, the anti-PTC antibodies were immobilized on the surface of the electrode by using 3-mercaptopropionic acid. The electrochemical performance of the fabricated immunosensor was studied using electrochemical impedance spectroscopy (EIS). The EIS method was used for the determination of PCT in the concentration range of 2.5–800 pg/mL with a limit of detection of 0.36 pg/mL. The effect of several interfering agents such as the C reactive protein (CRP), immunoglobulin G (IgG), and human serum albumin (HSA) was also studied. The fabricated immunosensor had a good selectivity to the PCT. The stability of the immunosensor was also studied for 1 month. The relative standard deviation (RSD) was obtained to be 5.2%.
Collapse
|
17
|
Bahamon-Pinzon D, Moreira G, Obare S, Vanegas D. Development of a nanocopper-decorated laser-scribed sensor for organophosphorus pesticide monitoring in aqueous samples. Mikrochim Acta 2022; 189:254. [PMID: 35697907 PMCID: PMC9192389 DOI: 10.1007/s00604-022-05355-w] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/18/2022] [Accepted: 05/15/2022] [Indexed: 10/29/2022]
Abstract
Organophosphorus pesticides are widely used in industrial agriculture and have been associated with water pollution and negative impacts on local ecosystems and communities. There is a need for testing technologies to detect the presence of pesticide residues in water sources, especially in developing countries where access to standard laboratory methods is cost prohibitive. Herein, we outline the development of a facile electrochemical sensor for amperometric determination of organophosphorus pesticides in environmental water samples. A three-electrode system was fabricated via UV laser-inscribing on a polyimide film. The working electrode was functionalized with copper nanoparticles with affinity toward organophosphate compounds. The sensor showed a limit of detection (LOD) of 3.42 ± 1.69 µM for glyphosate, 7.28 ± 1.20 µM for glufosinate, and 17.78 ± 7.68 µM for aminomethylphosphonic acid (AMPA). Sensitivity was highest for glyphosate (145.52 ± 36.73 nA⋅µM-1⋅cm-2) followed by glufosinate (56.98 ± 10.87 nA⋅µM-1⋅cm-2), and AMPA (30.92 ± 8.51 nA⋅µM-1⋅cm-2). The response of the sensor is not significantly affected by the presence of several ions and organic molecules commonly present in natural water samples. The developed sensor shows promising potential for facilitating environmental monitoring of organophosphorus pesticide residues, which is a current need in several parts of the world.
Collapse
Affiliation(s)
- David Bahamon-Pinzon
- Department of Environmental Engineering and Earth Sciences, Clemson University, Clemson, SC, USA.,Global Alliance for Rapid Diagnostics, Michigan State University, East Lancing, MI, USA
| | - Geisianny Moreira
- Department of Environmental Engineering and Earth Sciences, Clemson University, Clemson, SC, USA.,Global Alliance for Rapid Diagnostics, Michigan State University, East Lancing, MI, USA
| | - Sherine Obare
- Joint School of Nanoscience and Nanoengineering, North Carolina A&T State University and UNC Greensboro, Greensboro, NC, USA
| | - Diana Vanegas
- Department of Environmental Engineering and Earth Sciences, Clemson University, Clemson, SC, USA. .,Global Alliance for Rapid Diagnostics, Michigan State University, East Lancing, MI, USA. .,Interdisciplinary Group for Biotechnology Innovation and Ecosocial Change -BioNovo, Universidad del Valle, Cali, Colombia.
| |
Collapse
|
18
|
Reddy YVM, Shin JH, Palakollu VN, Sravani B, Choi CH, Park K, Kim SK, Madhavi G, Park JP, Shetti NP. Strategies, advances, and challenges associated with the use of graphene-based nanocomposites for electrochemical biosensors. Adv Colloid Interface Sci 2022; 304:102664. [PMID: 35413509 DOI: 10.1016/j.cis.2022.102664] [Citation(s) in RCA: 70] [Impact Index Per Article: 23.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/27/2021] [Revised: 03/18/2022] [Accepted: 04/04/2022] [Indexed: 12/29/2022]
Abstract
Graphene is an intriguing two-dimensional honeycomb-like carbon material with a unique basal plane structure, charge carrier mobility, thermal conductivity, wide electrochemical spectrum, and unusual physicochemical properties. Therefore, it has attracted considerable scientific interest in the field of nanoscience and bionanotechnology. The high specific surface area of graphene allows it to support high biomolecule loading for good detection sensitivity. As such, graphene, graphene oxide (GO), and reduced GO are excellent materials for the fabrication of new nanocomposites and electrochemical sensors. Graphene has been widely used as a chemical building block and/or scaffold with various materials to create highly sensitive and selective electrochemical sensing microdevices. Over the past decade, significant advancements have been made by utilizing graphene and graphene-based nanocomposites to design electrochemical sensors with enhanced analytical performance. This review focus on the synthetic strategies, as well as the structure-to-function studies of graphene, electrochemistry, novel multi nanocomposites combining graphene, limit of detection, stability, sensitivity, assay time. Finally, the review describes the challenges, strategies and outlook on the future development of graphene sensors technology that would be usable for the internet of things are also highlighted.
Collapse
|
19
|
Alhaddad AY, Aly H, Gad H, Al-Ali A, Sadasivuni KK, Cabibihan JJ, Malik RA. Sense and Learn: Recent Advances in Wearable Sensing and Machine Learning for Blood Glucose Monitoring and Trend-Detection. Front Bioeng Biotechnol 2022; 10:876672. [PMID: 35646863 PMCID: PMC9135106 DOI: 10.3389/fbioe.2022.876672] [Citation(s) in RCA: 19] [Impact Index Per Article: 6.3] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/15/2022] [Accepted: 04/12/2022] [Indexed: 12/12/2022] Open
Abstract
Diabetes mellitus is characterized by elevated blood glucose levels, however patients with diabetes may also develop hypoglycemia due to treatment. There is an increasing demand for non-invasive blood glucose monitoring and trends detection amongst people with diabetes and healthy individuals, especially athletes. Wearable devices and non-invasive sensors for blood glucose monitoring have witnessed considerable advances. This review is an update on recent contributions utilizing novel sensing technologies over the past five years which include electrocardiogram, electromagnetic, bioimpedance, photoplethysmography, and acceleration measures as well as bodily fluid glucose sensors to monitor glucose and trend detection. We also review methods that use machine learning algorithms to predict blood glucose trends, especially for high risk events such as hypoglycemia. Convolutional and recurrent neural networks, support vector machines, and decision trees are examples of such machine learning algorithms. Finally, we address the key limitations and challenges of these studies and provide recommendations for future work.
Collapse
Affiliation(s)
- Ahmad Yaser Alhaddad
- Department of Mechanical and Industrial Engineering, Qatar University, Doha, Qatar
| | - Hussein Aly
- KINDI Center for Computing Research, Qatar University, Doha, Qatar
| | - Hoda Gad
- Weill Cornell Medicine - Qatar, Doha, Qatar
| | - Abdulaziz Al-Ali
- KINDI Center for Computing Research, Qatar University, Doha, Qatar
| | | | - John-John Cabibihan
- Department of Mechanical and Industrial Engineering, Qatar University, Doha, Qatar
| | | |
Collapse
|
20
|
Matias TA, Rocha RG, Faria LV, Richter EM, Munoz RAA. Infrared laser‐induced graphene sensor for tyrosine detection. ChemElectroChem 2022. [DOI: 10.1002/celc.202200339] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/08/2022]
Affiliation(s)
- Tiago A. Matias
- Federal University of Uberlandia: Universidade Federal de Uberlandia Institute of Chemistry BRAZIL
| | - Raquel G. Rocha
- Federal University of Uberlandia: Universidade Federal de Uberlandia Institute of Chemistry BRAZIL
| | - Lucas V. Faria
- Federal University of Uberlandia: Universidade Federal de Uberlandia Institute of Chemistry BRAZIL
| | - Eduardo M. Richter
- Federal University of Uberlandia: Universidade Federal de Uberlandia Institute of Chemistry BRAZIL
| | - Rodrigo A. A. Munoz
- Federal University of Uberlandia Institute of Chemistry Av. Joao Naves de Avila 2121 - Bloco 1D 38408186 Uberlandia BRAZIL
| |
Collapse
|
21
|
Matias TA, de Faria LV, Rocha RG, Silva MNT, Nossol E, Richter EM, Muñoz RAA. Prussian blue-modified laser-induced graphene platforms for detection of hydrogen peroxide. Mikrochim Acta 2022; 189:188. [DOI: 10.1007/s00604-022-05295-5] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/24/2022] [Accepted: 03/22/2022] [Indexed: 10/18/2022]
|
22
|
Dixit N, Singh SP. Laser-Induced Graphene (LIG) as a Smart and Sustainable Material to Restrain Pandemics and Endemics: A Perspective. ACS OMEGA 2022; 7:5112-5130. [PMID: 35187327 PMCID: PMC8851616 DOI: 10.1021/acsomega.1c06093] [Citation(s) in RCA: 20] [Impact Index Per Article: 6.7] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 11/01/2021] [Accepted: 01/19/2022] [Indexed: 05/02/2023]
Abstract
A healthy environment is necessary for a human being to survive. The contagious COVID-19 virus has disastrously contaminated the environment, leading to direct or indirect transmission. Therefore, the environment demands adequate prevention and control strategies at the beginning of the viral spread. Laser-induced graphene (LIG) is a three-dimensional carbon-based nanomaterial fabricated in a single step on a wide variety of low-cost to high-quality carbonaceous materials without using any additional chemicals potentially used for antiviral, antibacterial, and sensing applications. LIG has extraordinary properties, including high surface area, electrical and thermal conductivity, environmental-friendliness, easy fabrication, and patterning, making it a sustainable material for controlling SARS-CoV-2 or similar pandemic transmission through different sources. LIG's antiviral, antibacterial, and antibiofouling properties were mainly due to the thermal and electrical properties and texture derived from nanofibers and micropores. This perspective will highlight the conducted research and the future possibilities on LIG for its antimicrobial, antiviral, antibiofouling, and sensing applications. It will also manifest the idea of incorporating this sustainable material into different technologies like air purifiers, antiviral surfaces, wearable sensors, water filters, sludge treatment, and biosensing. It will pave a roadmap to explore this single-step fabrication technique of graphene to deal with pandemics and endemics in the coming future.
Collapse
Affiliation(s)
- Nandini Dixit
- Environmental
Science and Engineering Department (ESED), Indian Institute of Technology Bombay, Mumbai 400076, India
| | - Swatantra P. Singh
- Environmental
Science and Engineering Department (ESED), Indian Institute of Technology Bombay, Mumbai 400076, India
- Centre
for Research in Nanotechnology & Science (CRNTS), Indian Institute of Technology Bombay, Mumbai 400076, India
- Interdisciplinary
Program in Climate Studies, Indian Institute
of Technology Bombay, Mumbai 400076, India
| |
Collapse
|
23
|
Zafar H, Channa A, Jeoti V, Stojanović GM. Comprehensive Review on Wearable Sweat-Glucose Sensors for Continuous Glucose Monitoring. SENSORS (BASEL, SWITZERLAND) 2022; 22:638. [PMID: 35062598 PMCID: PMC8781973 DOI: 10.3390/s22020638] [Citation(s) in RCA: 90] [Impact Index Per Article: 30.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 11/16/2021] [Revised: 12/16/2021] [Accepted: 12/31/2021] [Indexed: 02/07/2023]
Abstract
The incidence of diabetes is increasing at an alarming rate, and regular glucose monitoring is critical in order to manage diabetes. Currently, glucose in the body is measured by an invasive method of blood sugar testing. Blood glucose (BG) monitoring devices measure the amount of sugar in a small sample of blood, usually drawn from pricking the fingertip, and placed on a disposable test strip. Therefore, there is a need for non-invasive continuous glucose monitoring, which is possible using a sweat sensor-based approach. As sweat sensors have garnered much interest in recent years, this study attempts to summarize recent developments in non-invasive continuous glucose monitoring using sweat sensors based on different approaches with an emphasis on the devices that can potentially be integrated into a wearable platform. Numerous research entities have been developing wearable sensors for continuous blood glucose monitoring, however, there are no commercially viable, non-invasive glucose monitors on the market at the moment. This review article provides the state-of-the-art in sweat glucose monitoring, particularly keeping in sight the prospect of its commercialization. The challenges relating to sweat collection, sweat sample degradation, person to person sweat amount variation, various detection methods, and their glucose detection sensitivity, and also the commercial viability are thoroughly covered.
Collapse
Affiliation(s)
- Hima Zafar
- Faculty of Technical Sciences, University of Novi Sad, T. Dositeja Obradovića 6, 21000 Novi Sad, Serbia; (V.J.); (G.M.S.)
| | - Asma Channa
- Computer Science Department, University Politehnica of Bucharest, 060042 Bucharest, Romania;
- DIIES Department, Mediterranea University of Reggio Calabria, 89100 Reggio Calabria, Italy
| | - Varun Jeoti
- Faculty of Technical Sciences, University of Novi Sad, T. Dositeja Obradovića 6, 21000 Novi Sad, Serbia; (V.J.); (G.M.S.)
| | - Goran M. Stojanović
- Faculty of Technical Sciences, University of Novi Sad, T. Dositeja Obradovića 6, 21000 Novi Sad, Serbia; (V.J.); (G.M.S.)
| |
Collapse
|
24
|
Liu J, Ji H, Lv X, Zeng C, Li H, Li F, Qu B, Cui F, Zhou Q. Laser-induced graphene (LIG)-driven medical sensors for health monitoring and diseases diagnosis. Mikrochim Acta 2022; 189:54. [PMID: 35001163 PMCID: PMC8743164 DOI: 10.1007/s00604-021-05157-6] [Citation(s) in RCA: 34] [Impact Index Per Article: 11.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/28/2021] [Accepted: 12/26/2021] [Indexed: 02/05/2023]
Abstract
Laser-induced graphene (LIG) is a class of three-dimensional (3D) porous carbon nanomaterial. It can be prepared by direct laser writing on some polymer materials in the air. Because of its features of simplicity, fast production, and excellent physicochemical properties, it was widely used in medical sensing devices. This minireview gives an overview of the characteristics of LIG and LIG-driven sensors. Various methods for preparing graphene were compared and discussed. The applications of the LIG in biochemical sensors for ions, small molecules, microRNA, protein, and cell detection were highlighted. LIG-based physical physiological sensors and wearable electronics for medical applications were also included. Finally, our insights into current challenges and prospects for LIG-based medical sensing devices were presented.
Collapse
Affiliation(s)
- Jianlei Liu
- Department of Laboratory Medicine and Pathology, Foshan Fosun Chancheng Hospital, Foshan, 528000, Guangdong, China
| | - Haijie Ji
- The Ministry of Education Key Laboratory of Clinical Diagnostics, School of Laboratory Medicine, Chongqing Medical University, Chongqing, 400016, China
| | - Xiaoyan Lv
- Department of Dermatology, West China Hospital, West China School of Medicine, Sichuan University, Chengdu, 610041, China
| | - Chijia Zeng
- Department of Laboratory Medicine and Pathology, Foshan Fosun Chancheng Hospital, Foshan, 528000, Guangdong, China
| | - Heming Li
- College of Basic Medical Sciences, Harbin Medical University, Harbin, 150081, China
| | - Fugang Li
- Shanghai Engineering Research Center of iPOCT Medicine, Shanghai Industry Technology Innovation Strategic Alliance of iPOCT Medicine, Shanghai Upper Bio Tech Pharma Co., Ltd., Shanghai, 201201, China
| | - Bin Qu
- Biophysics, Center for Integrative Physiology and Molecular Medicine (CIPMM), School of Medicine, Saarland University, 66421, Homburg, Germany
| | - Feiyun Cui
- The Ministry of Education Key Laboratory of Clinical Diagnostics, School of Laboratory Medicine, Chongqing Medical University, Chongqing, 400016, China.
| | - Qin Zhou
- College of Basic Medical Sciences, Harbin Medical University, Harbin, 150081, China.
| |
Collapse
|
25
|
Balkourani G, Damartzis T, Brouzgou A, Tsiakaras P. Cost Effective Synthesis of Graphene Nanomaterials for Non-Enzymatic Electrochemical Sensors for Glucose: A Comprehensive Review. SENSORS (BASEL, SWITZERLAND) 2022; 22:355. [PMID: 35009895 PMCID: PMC8749877 DOI: 10.3390/s22010355] [Citation(s) in RCA: 19] [Impact Index Per Article: 6.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 10/25/2021] [Revised: 12/20/2021] [Accepted: 12/25/2021] [Indexed: 02/06/2023]
Abstract
The high conductivity of graphene material (or its derivatives) and its very large surface area enhance the direct electron transfer, improving non-enzymatic electrochemical sensors sensitivity and its other characteristics. The offered large pores facilitate analyte transport enabling glucose detection even at very low concentration values. In the current review paper we classified the enzymeless graphene-based glucose electrocatalysts' synthesis methods that have been followed into the last few years into four main categories: (i) direct growth of graphene (or oxides) on metallic substrates, (ii) in-situ growth of metallic nanoparticles into graphene (or oxides) matrix, (iii) laser-induced graphene electrodes and (iv) polymer functionalized graphene (or oxides) electrodes. The increment of the specific surface area and the high degree reduction of the electrode internal resistance were recognized as their common targets. Analyzing glucose electrooxidation mechanism over Cu- Co- and Ni-(oxide)/graphene (or derivative) electrocatalysts, we deduced that glucose electrochemical sensing properties, such as sensitivity, detection limit and linear detection limit, totally depend on the route of the mass and charge transport between metal(II)/metal(III); and so both (specific area and internal resistance) should have the optimum values.
Collapse
Affiliation(s)
- Georgia Balkourani
- Laboratory of Alternative Energy Conversion Systems, Department of Mechanical Engineering, University of Thessaly, Pedion Areos, 38334 Volos, Greece;
| | - Theodoros Damartzis
- Industrial Processes and Energy Systems Engineering, Institute of Mechanical Engineering, Sion, Ecole Polytechnique Fédérale de Lausanne, 1015 Lausanne, Switzerland;
| | - Angeliki Brouzgou
- Department of Energy Systems, School of Technology, University of Thessaly, Geopolis, Regional Road Trikala-Larisa, 41500 Larisa, Greece
| | - Panagiotis Tsiakaras
- Laboratory of Alternative Energy Conversion Systems, Department of Mechanical Engineering, University of Thessaly, Pedion Areos, 38334 Volos, Greece;
- Laboratory of Materials and Devices for Electrochemical Power Engineering, Institute of Chemical Engineering, Ural Federal University, 19 Mira Str., 620002 Yekaterinburg, Russia
- Laboratory of Electrochemical Devices Based on Solid Oxide Proton Electrolytes, Institute of High Temperature Electrochemistry (RAS), 620990 Yekaterinburg, Russia
| |
Collapse
|
26
|
Malathi S, Pakrudheen I, Kalkura SN, Webster T, Balasubramanian S. Disposable biosensors based on metal nanoparticles. SENSORS INTERNATIONAL 2022; 3:100169. [PMID: 35252890 PMCID: PMC8889882 DOI: 10.1016/j.sintl.2022.100169] [Citation(s) in RCA: 16] [Impact Index Per Article: 5.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 12/31/2021] [Revised: 02/28/2022] [Accepted: 03/01/2022] [Indexed: 02/06/2023] Open
Abstract
The coronavirus disease2019 (COVID-19) pandemic has highlighted the need for disposable biosensors that can detect viruses in infected patients quickly due to fast response and also at a low cost.The present review provides an overview of the applications of disposable biosensors based on metal nanoparticles in enzymatic and non-enzymatic sensors with special reference to glucose and H2O2, immunosensors as well as genosensors (DNA biosensors in which the recognized event consists of the hybridization reaction)for point-of-care diagnostics. The disposable biosensors for COVID19 have also been discussed.
Collapse
Affiliation(s)
- S. Malathi
- Crystal Growth Centre, Anna University, Guindy, Chennai, 600025, India
| | - I. Pakrudheen
- Department of Chemistry, CMR Institute of Technology, Bengaluru, 560037, Karnataka, India
| | | | - T.J. Webster
- Department of Chemical Engineering, Northeastern University, Boston, MA, 02115, USA
| | - S. Balasubramanian
- Department of Inorganic Chemistry, University of Madras, Guindy, Chennai, 600025, India,Corresponding author
| |
Collapse
|
27
|
Nagarajan RD, Sundaramurthy A, Sundramoorthy AK. Synthesis and characterization of MXene (Ti 3C 2T x)/Iron oxide composite for ultrasensitive electrochemical detection of hydrogen peroxide. CHEMOSPHERE 2022; 286:131478. [PMID: 34303904 DOI: 10.1016/j.chemosphere.2021.131478] [Citation(s) in RCA: 28] [Impact Index Per Article: 9.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 03/17/2021] [Revised: 06/11/2021] [Accepted: 07/06/2021] [Indexed: 06/13/2023]
Abstract
Due to the widespread usage of hydrogen peroxide (H2O2) in various consumer and industrial products (Examples: fuel cells and antibacterial agents), it became important to accurately detect H2O2 concentration in environmental, medical and food samples. Herein, titanium carbide Ti3C2Tx (MXene) was synthesized by using Ti, Al and C powders at high-temperature. Then, nanocrystalline iron oxide (α-Fe2O3) was obtained from a single solid-phase method. Using Ti3C2Tx and Fe2O3 powders, Ti3C2Tx-Fe2O3 nanocomposite was prepared by ultrasonication. As-synthesized, Ti3C2Tx-Fe2O3 composite had been characterized by UV-Visible (UV-Vis), Fourier transform infrared spectroscopy (FT-IR), X-ray diffraction (XRD) and Raman spectroscopy. The Fe2O3 nanoparticles (NPs) were decorated on the surface of Ti3C2Tx as observed by high resolution scanning electron microscopy (HR-SEM) and high resolution transmission electron microscopy (HR-TEM). The Ti3C2Tx nanosheets were formed with the average size of 400-500 nm. HR-SEM images of α-Fe2O3 showed that the coral-like particles with the average length ~5 μm were obtained. The electrochemical properties of the individual (Ti3C2Tx and α-Fe2O3) and composite materials (Ti3C2Tx-Fe2O3) were investigated by cyclic voltammetry (CV). Ti3C2Tx-Fe2O3 nanocomposite modified electrode had exhibited potent electro-catalytic activity for H2O2 reduction by reducing the overpotential about 320 mV and a linear response was recorded from 10 nM to 1 μM H2O2. The optimization of various parameters such as material composition ratio, amount of catalyst, effects of pH, scan rate and interference effects with other biomolecules were carried out. In addition, the kinetic parameters such as rate constant, diffusion coefficient and the active surface area of the electrodes were calculated. Moreover, the Ti3C2Tx-Fe2O3 composite modified electrode was used successfully to detect H2O2 in food and urine samples. We believe that Ti3C2Tx-Fe2O3 composite based materials could be used for the fabrication of non-enzymatic H2O2 sensors for medical diagnosis, food safety and environmental monitoring applications.
Collapse
Affiliation(s)
- Ramila D Nagarajan
- Department of Chemistry, SRM Institute of Science and Technology, Kattankulathur, 603 203, Tamil Nadu, India
| | - Anandhakumar Sundaramurthy
- SRM Research Institute, SRM Institute of Science and Technology, Kattankulathur, 603 203, Tamil Nadu, India
| | - Ashok K Sundramoorthy
- Department of Chemistry, SRM Institute of Science and Technology, Kattankulathur, 603 203, Tamil Nadu, India.
| |
Collapse
|
28
|
Zhu J, Huang X, Song W. Physical and Chemical Sensors on the Basis of Laser-Induced Graphene: Mechanisms, Applications, and Perspectives. ACS NANO 2021; 15:18708-18741. [PMID: 34881870 DOI: 10.1021/acsnano.1c05806] [Citation(s) in RCA: 49] [Impact Index Per Article: 12.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/27/2023]
Abstract
Laser-induced graphene (LIG) is produced rapidly by directly irradiating carbonaceous precursors, and it naturally exhibits as a three-dimensional porous structure. Due to advantages such as simple preparation, time-saving, environmental friendliness, low cost, and expanding categories of raw materials, LIG and its derivatives have achieved broad applications in sensors. This has been witnessed in various fields such as wearable devices, disease diagnosis, intelligent robots, and pollution detection. However, despite LIG sensors having demonstrated an excellent capability to monitor physical and chemical parameters, the systematic review of synthesis, sensing mechanisms, and applications of them combined with comparison against other preparation approaches of graphene is still lacking. Here, graphene-based sensors for physical, biological, and chemical detection are reviewed first, followed by the introduction of general preparation methods for the laser-induced method to yield graphene. The preparation and advantages of LIG, sensing mechanisms, and the properties of different types of emerging LIG-based sensors are comprehensively reviewed. Finally, possible solutions to the problems and challenges of preparing LIG and LIG-based sensors are proposed. This review may serve as a detailed reference to guide the development of LIG-based sensors that possess properties for future smart sensors in health care, environmental protection, and industrial production.
Collapse
Affiliation(s)
- Junbo Zhu
- Department of Chemistry, Capital Normal University, Beijing 100048, China
- Beijing Key Laboratory for Optical Materials and Photonic Devices, Beijing 100048, China
| | - Xian Huang
- Department of Biomedical Engineering, Tianjin University, Tianjin 300072, China
| | - Weixing Song
- Department of Chemistry, Capital Normal University, Beijing 100048, China
- Beijing Key Laboratory for Optical Materials and Photonic Devices, Beijing 100048, China
| |
Collapse
|
29
|
Chitare YM, Jadhav SB, Pawaskar PN, Magdum VV, Gunjakar JL, Lokhande CD. Metal Oxide-Based Composites in Nonenzymatic Electrochemical Glucose Sensors. Ind Eng Chem Res 2021. [DOI: 10.1021/acs.iecr.1c03662] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/26/2023]
Affiliation(s)
- Yogesh M. Chitare
- Centre for Interdisciplinary Research (CIR), D. Y. Patil Education Society (Institution Deemed to be University), Kolhapur 416 006, Maharashtra, India
| | - Satish B. Jadhav
- Centre for Interdisciplinary Research (CIR), D. Y. Patil Education Society (Institution Deemed to be University), Kolhapur 416 006, Maharashtra, India
| | - Padamaja N. Pawaskar
- Centre for Interdisciplinary Research (CIR), D. Y. Patil Education Society (Institution Deemed to be University), Kolhapur 416 006, Maharashtra, India
| | - Vikas V. Magdum
- Centre for Interdisciplinary Research (CIR), D. Y. Patil Education Society (Institution Deemed to be University), Kolhapur 416 006, Maharashtra, India
| | - Jayavant L. Gunjakar
- Centre for Interdisciplinary Research (CIR), D. Y. Patil Education Society (Institution Deemed to be University), Kolhapur 416 006, Maharashtra, India
| | - Chandrakant D. Lokhande
- Centre for Interdisciplinary Research (CIR), D. Y. Patil Education Society (Institution Deemed to be University), Kolhapur 416 006, Maharashtra, India
| |
Collapse
|
30
|
Zhu J, Liu S, Hu Z, Zhang X, Yi N, Tang K, Dexheimer MG, Lian X, Wang Q, Yang J, Gray J, Cheng H. Laser-induced graphene non-enzymatic glucose sensors for on-body measurements. Biosens Bioelectron 2021; 193:113606. [PMID: 34507206 PMCID: PMC8556579 DOI: 10.1016/j.bios.2021.113606] [Citation(s) in RCA: 78] [Impact Index Per Article: 19.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/25/2021] [Revised: 07/27/2021] [Accepted: 08/30/2021] [Indexed: 02/08/2023]
Abstract
Non-enzymatic glucose sensors outperform enzymatic ones in terms of cost, sensitivity, stability, and operating duration. Though highly sensitive, it is still desirable to further improve the sensitivity of non-enzymatic glucose sensors to detect a trace amount of glucose in sweat and other biofluids. Among the demonstrated effective approaches using bimetals or 3D porous structures, the porous laser-induced graphene (LIG) on flexible polymers showcases good conductivity and a simple fabrication process for the integration of sensing materials. The uniform electroless plating of the nickel and gold layer on LIG electrodes demonstrates significantly enhanced sensitivity and a large linear range for glucose sensing. The sensor with the porous LIG foam exhibits a high sensitivity of 1080 μA mM-1 cm-2, whereas a further increased sensitivity of 3500 μA mM-1 cm-2 is obtained with LIG fibers (LIGF). Impressively, a large linear range (0-30 mM) can be achieved by changing the bias voltage from 0.5 to 0.1 V due to the Au coating. Because the existing non-enzymatic glucose sensors are limited to use in basic solutions, their application in wearable electronics is elusive. In addition to the reduced requirement for the basic solution, this work integrates a porous encapsulating reaction cavity containing alkali solutions with a soft, skin-interfaced microfluidic component to provide integrated microfluidic non-enzymatic glucose sensors for sweat sampling and glucose sensing. The accurate glucose measurements from the human sweat and cell culture media showcase the practical utility, which opens up opportunities for the non-enzymatic glucose sensors in wearable electronics.
Collapse
Affiliation(s)
- Jia Zhu
- Department of Engineering Science and Mechanics, The Pennsylvania State University, University Park, PA, 16802, USA.
| | - Shangbin Liu
- Department of Engineering Science and Mechanics, The Pennsylvania State University, University Park, PA, 16802, USA
| | - Zhihui Hu
- Department of Engineering Science and Mechanics, The Pennsylvania State University, University Park, PA, 16802, USA; School of Logistics Engineering, Wuhan University of Technology, Wuhan, 430063, China
| | - Xianzhe Zhang
- Department of Engineering Science and Mechanics, The Pennsylvania State University, University Park, PA, 16802, USA
| | - Ning Yi
- Department of Engineering Science and Mechanics, The Pennsylvania State University, University Park, PA, 16802, USA; Department of Materials Science and Engineering, The Pennsylvania State University, University Park, PA, 16802, USA
| | - Kairui Tang
- Department of Engineering Science and Mechanics, The Pennsylvania State University, University Park, PA, 16802, USA
| | - Michael Gregory Dexheimer
- Department of Engineering Science and Mechanics, The Pennsylvania State University, University Park, PA, 16802, USA
| | - Xiaojun Lian
- Department of Biomedical Engineering, The Pennsylvania State University, University Park, PA, 16802, USA
| | - Qing Wang
- Department of Materials Science and Engineering, The Pennsylvania State University, University Park, PA, 16802, USA
| | - Jian Yang
- Department of Biomedical Engineering, The Pennsylvania State University, University Park, PA, 16802, USA
| | - Jennifer Gray
- Materials Research Institute, The Pennsylvania State University, University Park, PA, 16802, USA
| | - Huanyu Cheng
- Department of Engineering Science and Mechanics, The Pennsylvania State University, University Park, PA, 16802, USA; Department of Materials Science and Engineering, The Pennsylvania State University, University Park, PA, 16802, USA; Department of Biomedical Engineering, The Pennsylvania State University, University Park, PA, 16802, USA.
| |
Collapse
|
31
|
Beaver K, Dantanarayana A, Minteer SD. Materials Approaches for Improving Electrochemical Sensor Performance. J Phys Chem B 2021; 125:11820-11834. [PMID: 34677956 DOI: 10.1021/acs.jpcb.1c07063] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/12/2022]
Abstract
Electrochemical sensors have emerged as important diagnostic tools in recent years, due to their simplicity and ease of use. Compared to instrumental analysis methods that use complicated experimental and data analysis techniques─such as mass spectrometry, nuclear magnetic resonance (NMR), spectrophotometric methods, and chromatography─electrochemical sensors show promise for use in a wide range of real-time and in situ applications such as pharmaceutical testing, environmental monitoring, and medical diagnostics. In order to identify analytes in complex and/or biological samples, materials used for both the electrode materials and the chemically selective layer have been evolving throughout the years for optimizing the analytical performance of electrochemical sensors to increase sensitivity, selectivity and linear range. In this Perspective, attention will be focused on different types of materials that have been used for electrochemical sensing, including new combinations of well-studied materials as well as novel strategies to enhance the performance of sensing devices. The Perspective will also discuss existing challenges in the field and future strategies for addressing those challenges.
Collapse
Affiliation(s)
- Kevin Beaver
- Department of Chemistry, University of Utah, 315 S 1400 E, Salt Lake City, Utah 84112, United States
| | - Ashwini Dantanarayana
- Department of Chemistry, University of Utah, 315 S 1400 E, Salt Lake City, Utah 84112, United States
| | - Shelley D Minteer
- Department of Chemistry, University of Utah, 315 S 1400 E, Salt Lake City, Utah 84112, United States
| |
Collapse
|
32
|
Muzyka K, Xu G. Laser‐induced Graphene in Facts, Numbers, and Notes in View of Electroanalytical Applications: A Review. ELECTROANAL 2021. [DOI: 10.1002/elan.202100425] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/03/2023]
Affiliation(s)
- Kateryna Muzyka
- Laboratory of Analytical Optochemotronics Department of Biomedical Engineering Kharkiv National University of RadioElectronics Kharkiv 61166 Ukraine
| | - Guobao Xu
- State Key Laboratory of Electroanalytical Chemistry Changchun Institute of Applied Chemistry Chinese Academy of Sciences 5625 Renmin Street Changchun Jilin 130022 PR China
| |
Collapse
|
33
|
|
34
|
Aun TT, Salleh NM, Ali UFM, Manan NSA. Non-Enzymatic Glucose Sensors Involving Copper: An Electrochemical Perspective. Crit Rev Anal Chem 2021; 53:537-593. [PMID: 34477020 DOI: 10.1080/10408347.2021.1967720] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/18/2022]
Abstract
Non-enzymatic glucose sensors based on the use of copper and its oxides have emerged as promising candidates to replace enzymatic glucose sensors owing to their stability, ease of fabrication, and superior sensitivity. This review explains the theories of the mechanism of glucose oxidation on copper transition metal electrodes. It also presents an overview on the development of among the best non-enzymatic copper-based glucose sensors in the past 10 years. A brief description of methods, interesting findings, and important performance parameters are provided to inspire the reader and researcher to create new improvements in sensor design. Finally, several important considerations that pertain to the nano-structuring of the electrode surface is provided.
Collapse
Affiliation(s)
- Tan Tiek Aun
- Faculty of Science, Department of Chemistry, Universiti Malaya, Kuala Lumpur, Malaysia.,University Malaya Centre for Ionic Liquids (UMCiL), Universiti Malaya, Kuala Lumpur, Malaysia
| | - Noordini Mohamad Salleh
- Faculty of Science, Department of Chemistry, Universiti Malaya, Kuala Lumpur, Malaysia.,Faculty of Science, Department of Chemistry, Centre for Fundamental and Frontier Sciences in Nanostructure Self-Assembly, Universiti Malaya, Kuala Lumpur, Malaysia
| | - Umi Fazara Md Ali
- Chemical Engineering Programme, Faculty of Chemical Engineering & Technology, Universiti Malaysia Perlis, Arau, Malaysia.,Centre of Excellence for Biomass Utilization (COEBU), Universiti Malaysia Perlis, Arau, Malaysia
| | - Ninie Suhana Abdul Manan
- Faculty of Science, Department of Chemistry, Universiti Malaya, Kuala Lumpur, Malaysia.,University Malaya Centre for Ionic Liquids (UMCiL), Universiti Malaya, Kuala Lumpur, Malaysia
| |
Collapse
|
35
|
Khan I. Strategies for Improved Electrochemical CO 2 Reduction to Value-added Products by Highly Anticipated Copper-based Nanoarchitectures. CHEM REC 2021; 22:e202100219. [PMID: 34480411 DOI: 10.1002/tcr.202100219] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/11/2021] [Revised: 08/24/2021] [Indexed: 12/12/2022]
Abstract
Uncontrolled CO2 emission from various industrial and domestic sources is a considerable threat to environmental sustainability. Scientists are trying to develop multiple approaches to not only reduce CO2 emissions but also utilize this potent pollutant to get economically feasible products. The electrochemical reduction of CO2 (ERC) is one way to effectively convert CO2 to more useful products (ranging from C1 to C5). Nevertheless, this process is kinetically hindered and less selective towards a specific product and, consequently, requires an efficient electrocatalyst with characteristics like selectivity, stability, reusability, low cost, and environmentally benign. Owing to specified commercial features, copper (Cu)-based materials are highly anticipated and widely investigated for the last two decades. However, their non-modified polycrystalline Cu forms usually lack selectivity and lower overpotential of CO2 reduction. Therefore, extensive research is in progress to induce various alterations ranging from morphological and surface chemistry tuning to structural and optoelectrical characteristics modifications. This review provides an overview of those strategies to improve the CO2 conversion efficiency through Cu-based ERC into valuable C1, C2, and higher molecular weight hydrocarbons. The thermodynamics and kinetics of CO2 reduction via Cu-based electrocatalysts are discussed in detail with the support of the first principle DFT-based models. In the last portion of the review, the reported mechanisms for various products are summarized, with a short overview of the outlook. This review is expected to provide important basics as well as advanced information for experienced as well as new researchers to develop various strategies for Cu and related materials to achieve improved ERC.
Collapse
Affiliation(s)
- Ibrahim Khan
- School of Chemical Engineering & Materials Science, Chung-Ang University, 84 Heukseok-ro, Dongjak-gu, Seoul, 06974, Republic of Korea
| |
Collapse
|
36
|
Johnson ZT, Williams K, Chen B, Sheets R, Jared N, Li J, Smith EA, Claussen JC. Electrochemical Sensing of Neonicotinoids Using Laser-Induced Graphene. ACS Sens 2021; 6:3063-3071. [PMID: 34370948 DOI: 10.1021/acssensors.1c01082] [Citation(s) in RCA: 26] [Impact Index Per Article: 6.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/07/2023]
Abstract
Neonicotinoids are the fastest-growing insecticide accounting for over 25% of the global pesticide market and are capable of controlling a range of pests that damage croplands, home yards/gardens, and golf course greens. However, widespread use has led to nontarget organism decline in pollinators, insects, and birds, while chronic, sublethal effects on humans are still largely unknown. Therefore, there is a need to understand how prevalent neonicotinoids are in the environment as there are currently no commercially available field-deployable sensors capable of measuring neonicotinoid concentrations in surface waters. Herein, we report the first example of a laser-induced graphene (LIG) platform that utilizes electrochemical sensing for neonicotinoid detection. These graphene-based sensors are created through a scalable direct-write laser fabrication process that converts polyimide into LIG, which eliminates the need for chemical synthesis of graphene, ink formulation, masks, stencils, pattern rolls, and postprint annealing commonly associated with other printed graphene sensors. The LIG electrodes were capable of monitoring four major neonicotinoids (CLO, IMD, TMX, and DNT) with low detection limits (CLO, 823 nM; IMD, 384 nM; TMX, 338 nM; and DNT, 682 nM) and a rapid response time (∼10 s) using square-wave voltammetry without chemical/biological functionalization. Interference testing exhibited negligible responses from widely used pesticides including the broad-leaf insecticides parathion, paraoxon, and fipronil, as well as systemic herbicides glyphosate (roundup), atrazine, dicamba, and 2,4-dichlorophenoxyacetic acid. These scalable, graphene-based sensors have the potential for wide-scale mapping of neonicotinoids in watersheds and potential use in numerous electrochemical sensor devices.
Collapse
Affiliation(s)
- Zachary T. Johnson
- Department of Mechanical Engineering, Iowa State University of Science and Technology, 528 Bissell Road, Ames, Iowa 50010, United States
| | - Kelli Williams
- Department of Mechanical Engineering, Iowa State University of Science and Technology, 528 Bissell Road, Ames, Iowa 50010, United States
| | - Bolin Chen
- Department of Mechanical Engineering, Iowa State University of Science and Technology, 528 Bissell Road, Ames, Iowa 50010, United States
| | - Robert Sheets
- Department of Mechanical Engineering, Iowa State University of Science and Technology, 528 Bissell Road, Ames, Iowa 50010, United States
| | - Nathan Jared
- Department of Mechanical Engineering, Iowa State University of Science and Technology, 528 Bissell Road, Ames, Iowa 50010, United States
| | - Jingzhe Li
- Department of Chemistry, Iowa State University, Ames, Iowa 50011, United States
- The Ames Laboratory, U.S. Department of Energy, Ames, Iowa 50011, United States
| | - Emily A. Smith
- Department of Chemistry, Iowa State University, Ames, Iowa 50011, United States
- The Ames Laboratory, U.S. Department of Energy, Ames, Iowa 50011, United States
| | - Jonathan C. Claussen
- Department of Mechanical Engineering, Iowa State University of Science and Technology, 528 Bissell Road, Ames, Iowa 50010, United States
| |
Collapse
|
37
|
Settu K, Chiu PT, Huang YM. Laser-Induced Graphene-Based Enzymatic Biosensor for Glucose Detection. Polymers (Basel) 2021; 13:2795. [PMID: 34451332 PMCID: PMC8400493 DOI: 10.3390/polym13162795] [Citation(s) in RCA: 24] [Impact Index Per Article: 6.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/05/2021] [Revised: 08/13/2021] [Accepted: 08/17/2021] [Indexed: 02/03/2023] Open
Abstract
Laser-induced graphene (LIG) has recently been receiving increasing attention due to its simple fabrication and low cost. This study reports a flexible laser-induced graphene-based electrochemical biosensor fabricated on a polymer substrate by the laser direct engraving process. For this purpose, a 450 nm UV laser was employed to produce a laser-induced graphene electrode (LIGE) on a polyimide substrate. After the laser engraving of LIGE, the chitosan-glucose oxidase (GOx) composite was immobilized on the LIGE surface to develop the biosensor for glucose detection. It was observed that the developed LIGE biosensor exhibited good amperometric responses toward glucose detection over a wide linear range up to 8 mM. The GOx/chitosan-modified LIGE biosensor showed high sensitivity of 43.15 µA mM-1 cm-2 with a detection limit of 0.431 mM. The interference studies performed with some possible interfering compounds such as ascorbic acid, uric acid, and urea exhibited no interference as there was no difference observed in the amperometric glucose detection. It was suggested that the LIGE-based biosensor proposed herein was easy to prepare and could be used for low-cost, rapid, and sensitive/selective glucose detection.
Collapse
Affiliation(s)
- Kalpana Settu
- Department of Electrical Engineering, National Taipei University, New Taipei City 23741, Taiwan; (P.-T.C.); (Y.-M.H.)
| | | | | |
Collapse
|
38
|
Choudhury S, Roy S, Bhattacharya G, Fishlock S, Deshmukh S, Bhowmick S, McLaughlign J, Roy SS. Potentiometric ion-selective sensors based on UV-ozone irradiated laser-induced graphene electrode. Electrochim Acta 2021. [DOI: 10.1016/j.electacta.2021.138341] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/21/2022]
|
39
|
Pereira SO, Santos NF, Carvalho AF, Fernandes AJS, Costa FM. Electrochemical Response of Glucose Oxidase Adsorbed on Laser-Induced Graphene. NANOMATERIALS 2021; 11:nano11081893. [PMID: 34443722 PMCID: PMC8401569 DOI: 10.3390/nano11081893] [Citation(s) in RCA: 8] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 06/17/2021] [Revised: 07/09/2021] [Accepted: 07/20/2021] [Indexed: 01/06/2023]
Abstract
Carbon-based electrodes have demonstrated great promise as electrochemical transducers in the development of biosensors. More recently, laser-induced graphene (LIG), a graphene derivative, appears as a great candidate due to its superior electron transfer characteristics, high surface area and simplicity in its synthesis. The continuous interest in the development of cost-effective, more stable and reliable biosensors for glucose detection make them the most studied and explored within the academic and industry community. In this work, the electrochemistry of glucose oxidase (GOx) adsorbed on LIG electrodes is studied in detail. In addition to the well-known electroactivity of free flavin adenine dinucleotide (FAD), the cofactor of GOx, at the expected half-wave potential of -0.490 V vs. Ag/AgCl (1 M KCl), a new well-defined redox pair at 0.155 V is observed and shown to be related to LIG/GOx interaction. A systematic study was undertaken in order to understand the origin of this activity, including scan rate and pH dependence, along with glucose detection tests. Two protons and two electrons are involved in this reaction, which is shown to be sensitive to the concentration of glucose, restraining its origin to the electron transfer from FAD in the active site of GOx to the electrode via direct or mediated by quinone derivatives acting as mediators.
Collapse
|
40
|
Balkourani G, Brouzgou A, Archonti M, Papandrianos N, Song S, Tsiakaras P. Emerging materials for the electrochemical detection of COVID-19. J Electroanal Chem (Lausanne) 2021; 893:115289. [PMID: 33907536 PMCID: PMC8062413 DOI: 10.1016/j.jelechem.2021.115289] [Citation(s) in RCA: 35] [Impact Index Per Article: 8.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/07/2021] [Revised: 04/18/2021] [Accepted: 04/19/2021] [Indexed: 02/07/2023]
Abstract
The SARS-CoV-2 virus is still causing a dramatic loss of human lives worldwide, constituting an unprecedented challenge for the society, public health and economy, to overcome. The up-to-date diagnostic tests, PCR, antibody ELISA and Rapid Antigen, require special equipment, hours of analysis and special staff. For this reason, many research groups have focused recently on the design and development of electrochemical biosensors for the SARS-CoV-2 detection, indicating that they can play a significant role in controlling COVID disease. In this review we thoroughly discuss the transducer electrode nanomaterials investigated in order to improve the sensitivity, specificity and response time of the as-developed SARS-CoV-2 electrochemical biosensors. Particularly, we mainly focus on the results appeard on Au-based and carbon or graphene-based electrodes, which are the main material groups recently investigated worldwidely. Additionally, the adopted electrochemical detection techniques are also discussed, highlighting their pros and cos. The nanomaterial-based electrochemical biosensors could enable a fast, accurate and without special cost, virus detection. However, further research is required in terms of new nanomaterials and synthesis strategies in order the SARS-CoV-2 electrochemical biosensors to be commercialized.
Collapse
Affiliation(s)
- G Balkourani
- Laboratory of Alternative Energy Conversion Systems, Department of Mechanical Engineering, School of Engineering, University of Thessaly, 1 Sekeri Str., Pedion Areos, 38834 Volos, Greece
| | - A Brouzgou
- Laboratory of Alternative Energy Conversion Systems, Department of Mechanical Engineering, School of Engineering, University of Thessaly, 1 Sekeri Str., Pedion Areos, 38834 Volos, Greece
- Department of Energy Systems, Faculty of Technology, University of Thessaly, Geopolis, 41500 Larissa, Greece
| | - M Archonti
- Laboratory of Alternative Energy Conversion Systems, Department of Mechanical Engineering, School of Engineering, University of Thessaly, 1 Sekeri Str., Pedion Areos, 38834 Volos, Greece
| | - N Papandrianos
- Department of Energy Systems, Faculty of Technology, University of Thessaly, Geopolis, 41500 Larissa, Greece
| | - S Song
- The Key Lab of Low-carbon Chemistry & Energy Conservation of Guangdong Province, PCFM Lab, School of Materials Science and Engineering, School of Chemical Engineering and Technology, Sun Yat-sen University, Guangzhou 510275, PR China
| | - P Tsiakaras
- Laboratory of Alternative Energy Conversion Systems, Department of Mechanical Engineering, School of Engineering, University of Thessaly, 1 Sekeri Str., Pedion Areos, 38834 Volos, Greece
- Laboratory of Materials and Devices for Clean Energy, Department of Technology of Electrochemical Processes, Ural Federal University, 19 Mira Str., Yekaterinburg 620002, Russian Federation
- Laboratory of Electrochemical Devices based on Solid Oxide Proton Electrolytes, Institute of High Temperature Electrochemistry (RAS), Yekaterinburg 620990, Russian Federation
| |
Collapse
|
41
|
Hashemi SA, Mousavi SM, Bahrani S, Omidifar N, Arjmand M, Ramakrishna S, Hagfeldt A, Lankarani KB, Chiang WH. Decorated graphene oxide flakes with integrated complex of 8-hydroxyquinoline/NiO toward accurate detection of glucose at physiological conditions. J Electroanal Chem (Lausanne) 2021; 893:115303. [DOI: 10.1016/j.jelechem.2021.115303] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/05/2023]
|
42
|
Disposable and portable gold nanoparticles modified - laser-scribed graphene sensing strips for electrochemical, non-enzymatic detection of glucose. Electrochim Acta 2021. [DOI: 10.1016/j.electacta.2021.138132] [Citation(s) in RCA: 23] [Impact Index Per Article: 5.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/05/2023]
|
43
|
Gao J, He S, Nag A. Electrochemical Detection of Glucose Molecules Using Laser-Induced Graphene Sensors: A Review. SENSORS (BASEL, SWITZERLAND) 2021; 21:2818. [PMID: 33923790 PMCID: PMC8073164 DOI: 10.3390/s21082818] [Citation(s) in RCA: 8] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 03/20/2021] [Revised: 04/06/2021] [Accepted: 04/14/2021] [Indexed: 02/07/2023]
Abstract
This paper deals with recent progress in the use of laser-induced graphene sensors for the electrochemical detection of glucose molecules. The exponential increase in the exploitation of the laser induction technique to generate porous graphene from polymeric and other naturally occurring materials has provided a podium for researchers to fabricate flexible sensors with high dynamicity. These sensors have been employed largely for electrochemical applications due to their distinct advantages like high customization in their structural dimensions, enhanced characteristics and easy roll-to-roll production. These laser-induced graphene (LIG)-based sensors have been employed for a wide range of sensorial applications, including detection of ions at varying concentrations. Among the many pivotal electrochemical uses in the biomedical sector, the use of these prototypes to monitor the concentration of glucose molecules is constantly increasing due to the essentiality of the presence of these molecules at specific concentrations in the human body. This paper shows a categorical classification of the various uses of these sensors based on the type of materials involved in the fabrication of sensors. The first category constitutes examples where the electrodes have been functionalized with various forms of copper and other types of metallic nanomaterials. The second category includes other miscellaneous forms where the use of both pure and composite forms of LIG-based sensors has been shown. Finally, the paper concludes with some of the possible measures that can be taken to enhance the use of this technique to generate optimized sensing prototypes for a wider range of applications.
Collapse
Affiliation(s)
- Jingrong Gao
- College of Light Industry and Food Science, South China University of Technology, Guangzhou 510006, China;
| | - Shan He
- School of Chemistry and Chemical Engineering, Guangzhou University, Guangzhou 510006, China;
- Institute for NanoScale Science and Technology, College of Science and Engineering, Flinders University, 5042 Bedford Park, Australia
| | - Anindya Nag
- School of Information Science and Engineering, Shandong University, Jinan 251600, China
| |
Collapse
|
44
|
Behrent A, Griesche C, Sippel P, Baeumner AJ. Process-property correlations in laser-induced graphene electrodes for electrochemical sensing. Mikrochim Acta 2021; 188:159. [PMID: 33829346 PMCID: PMC8026455 DOI: 10.1007/s00604-021-04792-3] [Citation(s) in RCA: 31] [Impact Index Per Article: 7.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/20/2020] [Accepted: 03/18/2021] [Indexed: 12/01/2022]
Abstract
Laser-induced graphene (LIG) has emerged as a promising electrode material for electrochemical point-of-care diagnostics. LIG offers a large specific surface area and excellent electron transfer at low-cost in a binder-free and rapid fabrication process that lends itself well to mass production outside of the cleanroom. Various LIG micromorphologies can be generated when altering the energy input parameters, and it was investigated here which impact this has on their electroanalytical characteristics and performance. Energy input is well controlled by the laser power, scribing speed, and laser pulse density. Once the threshold of required energy input is reached a broad spectrum of conditions leads to LIG with micromorphologies ranging from delicate irregular brush structures obtained at fast, high energy input, to smoother and more wall like albeit still porous materials. Only a fraction of these LIG structures provided high conductance which is required for appropriate electroanalytical performance. Here, it was found that low, frequent energy input provided the best electroanalytical material, i.e., low levels of power and speed in combination with high spatial pulse density. For example, the sensitivity for the reduction of K3[Fe(CN)6] was increased almost 2-fold by changing fabrication parameters from 60% power and 100% speed to 1% power and 10% speed. These general findings can be translated to any LIG fabrication process independent of devices used. The simple fabrication process of LIG electrodes, their good electroanalytical performance as demonstrated here with a variety of (bio)analytically relevant molecules including ascorbic acid, dopamine, uric acid, p-nitrophenol, and paracetamol, and possible application to biological samples make them ideal and inexpensive transducers for electrochemical (bio)sensors, with the potential to replace the screen-printed systems currently dominating in on-site sensors used. Graphical abstract ![]()
Collapse
Affiliation(s)
- Arne Behrent
- Institute of Analytical Chemistry, Chemo- and Biosensors, University of Regensburg, Regensburg, Germany
| | - Christian Griesche
- Institute of Analytical Chemistry, Chemo- and Biosensors, University of Regensburg, Regensburg, Germany
| | - Paul Sippel
- Institute of Analytical Chemistry, Chemo- and Biosensors, University of Regensburg, Regensburg, Germany
| | - Antje J Baeumner
- Institute of Analytical Chemistry, Chemo- and Biosensors, University of Regensburg, Regensburg, Germany.
| |
Collapse
|
45
|
Khazraei A, Tarlani A, Eslami-Moghadam M, Muzart J. New Bi 2MoO 6 nano-shapes toward ultrasensitive enzymeless glucose tracing: Synergetic effect of the Bi-Mo association. Talanta 2021; 221:121560. [PMID: 33076113 DOI: 10.1016/j.talanta.2020.121560] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/29/2020] [Revised: 08/09/2020] [Accepted: 08/10/2020] [Indexed: 10/23/2022]
Abstract
In a novel approach, an efficient non-enzymatic glucose sensor based on pure phase of aurivillius bismuth molybdate (BM or γ-Bi2MoO6) mixed metal oxides is reported. Three BM samples were synthesized, with/without l-cysteine (Cys) and dodecylamine (DDA) as additives, leading to different shapes: bullet (BM-C), confetti (BM-2Cys) and candy (BM-2DDA). The morphology and purity of the structures were confirmed by FE-SEM images and XRD. In order to investigate the sensor application, the samples were integrated on reduced graphene oxide and incorporated into simple and inexpensive glassy carbon electrode (GCE) without using any polyvinylpyrrolidone (PVP) or Nafion. To perform cyclic voltammetry experiments, all three biosensors were measured in PBS solution (pH = 7) in ±1.5 voltage range and 50 mV s-1 scan rate. Glucose identification by the synthesized composites is an obvious sign of their high efficiency. According to chronoamperomograms, the best sensitivity of 3050 μA L mmol-1 cm-2 with linear range of 0.02-0.14 mmol L-1, low detection limit (LOD) of 0.004 mmol L-1 and the signal/noise equal to 3 was achieved by BM-2DDA/rGO/GCE biosensor and its speedy amperometric response is less than 5 s. This biosensor showed impressive selectivity, repeatability and reproducibility results besides it maintains its stability considerably in great percentage of 98.5% after eight weeks. Also it showed prolonged stability after 50 min.
Collapse
Affiliation(s)
- Avideh Khazraei
- Chemistry & Chemical Engineering Research Center of Iran, Pajoohesh Blvd., Km 17, Karaj Hwy, Tehran, 14968-13151, Iran
| | - Aliakbar Tarlani
- Chemistry & Chemical Engineering Research Center of Iran, Pajoohesh Blvd., Km 17, Karaj Hwy, Tehran, 14968-13151, Iran.
| | - Mahboube Eslami-Moghadam
- Chemistry & Chemical Engineering Research Center of Iran, Pajoohesh Blvd., Km 17, Karaj Hwy, Tehran, 14968-13151, Iran
| | - Jacques Muzart
- Institut de Chimie Moléculaire de Reims, CNRS-Université de Reims Champagne-Ardenne, BP 1039, 51687, Reims Cedex 2, France
| |
Collapse
|
46
|
Xu Y, Fei Q, Page M, Zhao G, Ling Y, Chen D, Yan Z. Laser-induced graphene for bioelectronics and soft actuators. NANO RESEARCH 2021; 14:3033-3050. [PMID: 33841746 PMCID: PMC8023525 DOI: 10.1007/s12274-021-3441-9] [Citation(s) in RCA: 34] [Impact Index Per Article: 8.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 11/13/2020] [Revised: 03/06/2021] [Accepted: 03/07/2021] [Indexed: 05/18/2023]
Abstract
Laser-assisted process can enable facile, mask-free, large-area, inexpensive, customizable, and miniaturized patterning of laser-induced porous graphene (LIG) on versatile carbonaceous substrates (e.g., polymers, wood, food, textiles) in a programmed manner at ambient conditions. Together with high tailorability of its porosity, morphology, composition, and electrical conductivity, LIG can find wide applications in emerging bioelectronics (e.g., biophysical and biochemical sensing) and soft robots (e.g., soft actuators). In this review paper, we first introduce the methods to make LIG on various carbonaceous substrates and then discuss its electrical, mechanical, and antibacterial properties and biocompatibility that are critical for applications in bioelectronics and soft robots. Next, we overview the recent studies of LIG-based biophysical (e.g., strain, pressure, temperature, hydration, humidity, electrophysiological) sensors and biochemical (e.g., gases, electrolytes, metabolites, pathogens, nucleic acids, immunology) sensors. The applications of LIG in flexible energy generators and photodetectors are also introduced. In addition, LIG-enabled soft actuators that can respond to chemicals, electricity, and light stimulus are overviewed. Finally, we briefly discuss the future challenges and opportunities of LIG fabrications and applications.
Collapse
Affiliation(s)
- Yadong Xu
- Department of Biomedical, Biological & Chemical Engineering, University of Missouri, Columbia, Missouri 65211 USA
| | - Qihui Fei
- Department of Biomedical, Biological & Chemical Engineering, University of Missouri, Columbia, Missouri 65211 USA
| | - Margaret Page
- Department of Mechanical & Aerospace Engineering, University of Missouri, Columbia, Missouri 65211 USA
| | - Ganggang Zhao
- Department of Mechanical & Aerospace Engineering, University of Missouri, Columbia, Missouri 65211 USA
| | - Yun Ling
- Department of Mechanical & Aerospace Engineering, University of Missouri, Columbia, Missouri 65211 USA
| | - Dick Chen
- Rock Bridge High School, Columbia, Missouri 65203 USA
| | - Zheng Yan
- Department of Biomedical, Biological & Chemical Engineering, University of Missouri, Columbia, Missouri 65211 USA
- Department of Mechanical & Aerospace Engineering, University of Missouri, Columbia, Missouri 65211 USA
| |
Collapse
|
47
|
Lahcen AA, Rauf S, Beduk T, Durmus C, Aljedaibi A, Timur S, Alshareef HN, Amine A, Wolfbeis OS, Salama KN. Electrochemical sensors and biosensors using laser-derived graphene: A comprehensive review. Biosens Bioelectron 2020; 168:112565. [PMID: 32927277 DOI: 10.1016/j.bios.2020.112565] [Citation(s) in RCA: 84] [Impact Index Per Article: 16.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/30/2020] [Revised: 08/22/2020] [Accepted: 08/24/2020] [Indexed: 12/12/2022]
Abstract
Laser-derived graphene (LDG) technology is gaining attention as a promising material for the development of novel electrochemical sensors and biosensors. Compared to established methods for graphene synthesis, LDG provides many advantages such as cost-effectiveness, fast electron mobility, mask-free, green synthesis, good electrical conductivity, porosity, mechanical stability, and large surface area. This review discusses, in a critical way, recent advancements in this field. First, we focused on the fabrication and doping of LDG platforms using different strategies. Next, the techniques for the modification of LDG sensors using nanomaterials, conducting polymers, biological and artificial receptors are presented. We then discussed the advances achieved for various LDG sensing and biosensing schemes and their applications in the fields of environmental monitoring, food safety, and clinical diagnosis. Finally, the drawbacks and limitations of LDG based electrochemical biosensors are addressed, and future trends are also highlighted.
Collapse
Affiliation(s)
- Abdellatif Ait Lahcen
- Sensors Lab, Advanced Membranes and Porous Materials Center (AMPMC), Computer, Electrical and Mathematical Science and Engineering Division, King Abdullah University of Science and Technology (KAUST), Thuwal, 23955-6900, Saudi Arabia.
| | - Sakandar Rauf
- Sensors Lab, Advanced Membranes and Porous Materials Center (AMPMC), Computer, Electrical and Mathematical Science and Engineering Division, King Abdullah University of Science and Technology (KAUST), Thuwal, 23955-6900, Saudi Arabia
| | - Tutku Beduk
- Sensors Lab, Advanced Membranes and Porous Materials Center (AMPMC), Computer, Electrical and Mathematical Science and Engineering Division, King Abdullah University of Science and Technology (KAUST), Thuwal, 23955-6900, Saudi Arabia
| | - Ceren Durmus
- Department of Biochemistry, Faculty of Science, Ege University, 35100, Bornova, Izmir, Turkey
| | - Abdulrahman Aljedaibi
- Sensors Lab, Advanced Membranes and Porous Materials Center (AMPMC), Computer, Electrical and Mathematical Science and Engineering Division, King Abdullah University of Science and Technology (KAUST), Thuwal, 23955-6900, Saudi Arabia
| | - Suna Timur
- Department of Biochemistry, Faculty of Science, Ege University, 35100, Bornova, Izmir, Turkey
| | - Husam N Alshareef
- Materials Science and Engineering, Physical Science & Engineering Division, King Abdullah University of Science and Technology (KAUST), Thuwal, 23955-6900, Saudi Arabia.
| | - Aziz Amine
- Chemical Analysis and Biosensors Group, Laboratory of Process Engineering and Environment, Faculty of Science and Techniques, Hassan II University of Casablanca, B.P. 146. Mohammedia, Morocco.
| | - Otto S Wolfbeis
- Institute of Analytical Chemistry, Chemo- and Biosensors, University of Regensburg, D-93040, Regensburg, Germany.
| | - Khaled N Salama
- Sensors Lab, Advanced Membranes and Porous Materials Center (AMPMC), Computer, Electrical and Mathematical Science and Engineering Division, King Abdullah University of Science and Technology (KAUST), Thuwal, 23955-6900, Saudi Arabia.
| |
Collapse
|
48
|
A Brief Description of Cyclic Voltammetry Transducer-Based Non-Enzymatic Glucose Biosensor Using Synthesized Graphene Electrodes. APPLIED SYSTEM INNOVATION 2020. [DOI: 10.3390/asi3030032] [Citation(s) in RCA: 12] [Impact Index Per Article: 2.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 01/09/2023]
Abstract
The essential disadvantages of conventional glucose enzymatic biosensors such as high fabrication cost, poor stability of enzymes, pH value-dependent, and dedicated limitations, have been increasing the attraction of non-enzymatic glucose sensors research. Beneficially, patients with diabetes could use this type of sensor as a fourth-generation of glucose sensors with a very low cost and high performance. We demonstrate the most common acceptable transducer for a non-enzymatic glucose biosensor with a brief description of how it works. The review describes the utilization of graphene and its composites as new materials for high-performance non-enzymatic glucose biosensors. The electrochemical properties of graphene and the electrochemical characterization using the cyclic voltammetry (CV) technique of electrocatalysis electrodes towards glucose oxidation have been summarized. A recent synthesis method of the graphene-based electrodes for non-enzymatic glucose sensors have been introduced along with this study. Finally, the electrochemical properties such as linearity, sensitivity, and the limit of detection (LOD) for each sensor are introduced with a comparison with each other to figure out their strengths and weaknesses.
Collapse
|
49
|
Soares RRA, Hjort RG, Pola CC, Parate K, Reis EL, Soares NFF, McLamore ES, Claussen JC, Gomes CL. Laser-Induced Graphene Electrochemical Immunosensors for Rapid and Label-Free Monitoring of Salmonella enterica in Chicken Broth. ACS Sens 2020; 5:1900-1911. [PMID: 32348124 DOI: 10.1021/acssensors.9b02345] [Citation(s) in RCA: 119] [Impact Index Per Article: 23.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/20/2022]
Abstract
Food-borne illnesses are a growing concern for the food industry and consumers, with millions of cases reported every year. Consequently, there is a critical need to develop rapid, sensitive, and inexpensive techniques for pathogen detection in order to mitigate this problem. However, current pathogen detection strategies mainly include time-consuming laboratory methods and highly trained personnel. Electrochemical in-field biosensors offer a rapid, low-cost alternative to laboratory techniques, but the electrodes used in these biosensors require expensive nanomaterials to increase their sensitivity, such as noble metals (e.g., platinum, gold) or carbon nanomaterials (e.g., carbon nanotubes, or graphene). Herein, we report the fabrication of a highly sensitive and label-free laser-induced graphene (LIG) electrode that is subsequently functionalized with antibodies to electrochemically quantify the food-borne pathogen Salmonella enterica serovar Typhimurium. The LIG electrodes were produced by laser induction on the polyimide film in ambient conditions and, hence, circumvent the need for high-temperature, vacuum environment, and metal seed catalysts commonly associated with graphene-based electrodes fabricated via chemical vapor deposition processes. After functionalization with Salmonella antibodies, the LIG biosensors were able to detect live Salmonella in chicken broth across a wide linear range (25 to 105 CFU mL-1) and with a low detection limit (13 ± 7 CFU mL-1; n = 3, mean ± standard deviation). These results were acquired with an average response time of 22 min without the need for sample preconcentration or redox labeling techniques. Moreover, these LIG immunosensors displayed high selectivity as demonstrated by nonsignificant response to other bacteria strains. These results demonstrate how LIG-based electrodes can be used for electrochemical immunosensing in general and, more specifically, could be used as a viable option for rapid and low-cost pathogen detection in food processing facilities before contaminated foods reach the consumer.
Collapse
Affiliation(s)
- Raquel R. A. Soares
- Department of Mechanical Engineering, Iowa State University, Ames 50011, Iowa, United States
- Department of Food Technology, Federal University of Viçosa, Viçosa 36570-900, Brazil
| | - Robert G. Hjort
- Department of Mechanical Engineering, Iowa State University, Ames 50011, Iowa, United States
| | - Cicero C. Pola
- Department of Mechanical Engineering, Iowa State University, Ames 50011, Iowa, United States
| | - Kshama Parate
- Department of Mechanical Engineering, Iowa State University, Ames 50011, Iowa, United States
| | - Efraim L. Reis
- Department of Chemistry, Federal University of Vicosa, Viçosa 36570-900, Brazil
| | - Nilda F. F. Soares
- Department of Food Technology, Federal University of Viçosa, Viçosa 36570-900, Brazil
| | - Eric S. McLamore
- Agricultural & Biological Engineering, University of Florida, Gainesville 32611, Florida, United States
| | - Jonathan C. Claussen
- Department of Mechanical Engineering, Iowa State University, Ames 50011, Iowa, United States
| | - Carmen L. Gomes
- Department of Mechanical Engineering, Iowa State University, Ames 50011, Iowa, United States
| |
Collapse
|
50
|
Significance of nanomaterials in electrochemical glucose sensors: An updated review (2016-2020). Biosens Bioelectron 2020; 159:112165. [DOI: 10.1016/j.bios.2020.112165] [Citation(s) in RCA: 156] [Impact Index Per Article: 31.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/13/2020] [Revised: 03/05/2020] [Accepted: 03/20/2020] [Indexed: 02/02/2023]
|