1
|
B K V, T R S. Monitoring Antibiotic Pollutants in Water Using Electrochemical Techniques: A Detailed Review. Crit Rev Anal Chem 2025:1-30. [PMID: 39773103 DOI: 10.1080/10408347.2024.2390549] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/11/2025]
Abstract
This review article examines the application of electrochemical methods for detecting four prevalent antibiotics - azithromycin (AZM), amoxicillin (AMX), tetracycline (TC), and ciprofloxacin (CIP) - in environmental monitoring. Although, antibiotics are essential to contemporary treatment, their widespread usage has contaminated the environment and given rise to antibiotic resistance. Electrochemical techniques offer sensitive, rapid, and cost-effective solutions for monitoring these antibiotics, addressing the limitations of traditional methods. The review provides a comprehensive analysis of various electrochemical approaches, including voltammetry, amperometry, photoelectrochemical and so on, highlighting their principles, advantages, and limitations. Key findings underscore the effectiveness of these methods in detecting antibiotics at trace levels in complex environmental matrices. Implications for environmental health and policy are discussed, emphasizing the importance of reliable detection techniques in mitigating antibiotic resistance and safeguarding ecosystems. Lastly, the article outlines future research directions aimed at enhancing the sensitivity, selectivity, and field-applicability of electrochemical sensors, thus advancing their utility in environmental monitoring and public health protection.
Collapse
Affiliation(s)
- Vinay B K
- Department of Electronics and Communication Engineering, Vidyavardhaka College of Engineering, Mysuru, Karnataka, India
| | - Suranjan T R
- Department of Electronics and Communication Engineering, Vidyavardhaka College of Engineering, Mysuru, Karnataka, India
| |
Collapse
|
2
|
Bruce-Tagoe TA, Bhaskar S, Kavle RR, Jeevanandam J, Acquah C, Ohemeng-Boahen G, Agyei D, Danquah MK. Advances in aptamer-based biosensors for monitoring foodborne pathogens. JOURNAL OF FOOD SCIENCE AND TECHNOLOGY 2024; 61:1252-1271. [PMID: 38910921 PMCID: PMC11190136 DOI: 10.1007/s13197-023-05889-8] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Revised: 09/27/2023] [Accepted: 10/21/2023] [Indexed: 06/25/2024]
Abstract
Biosensors are analytical devices for detecting a wide range of targets, including cells, proteins, DNA, enzymes, and chemical and biological compounds. They mostly rely on using bioprobes with a high binding affinity to the target for specific detection. However, low specificity and effectiveness of the conventional biosensors has led to the search for novel materials, that can specifically detect biomolecules. Aptamers are a group of single-stranded DNA or RNA oligonucleotides, that can bind to their targets with high specificity and serve as effective bioprobes for developing aptamer-based biosensors. Aptamers have a shorter production time, high stability, compared to traditional bioprobes, and possess ability to develop them for specific target molecules for tailored applications. Thus, various aptasensing approaches, including electrochemical, optical, surface plasmon resonance and chip-dependent approaches, have been investigated in recent times for various biological targets, including foodborne pathogens. Hence, this article is an overview of various conventional foodborne pathogen detection methods, their limitations and the ability of aptamer-based biosensors to overcome those limitations and replace them. In addition, the current status and advances in aptamer-based biosensors for the detection of foodborne pathogens to ensure food safety were also discussed. Supplementary Information The online version contains supplementary material available at 10.1007/s13197-023-05889-8.
Collapse
Affiliation(s)
| | - Shyju Bhaskar
- Department of Food Science, University of Otago, Dunedin, 9056 New Zealand
| | - Ruchita Rao Kavle
- Department of Food Science, University of Otago, Dunedin, 9056 New Zealand
| | - Jaison Jeevanandam
- CQM - Centro de Química da Madeira, Universidade da Madeira, Campus da Penteada, 9020-105 Funchal, Portugal
| | - Caleb Acquah
- Faculty of Health Sciences, University of Ottawa, Ottawa, ON K1H 8M5 Canada
| | - Godfred Ohemeng-Boahen
- Department of Chemical Engineering, Kwame Nkrumah University of Science and Technology, UPO, Kumasi, Ghana
| | - Dominic Agyei
- Department of Food Science, University of Otago, Dunedin, 9056 New Zealand
| | - Michael K. Danquah
- Chemical Engineering Department, University of Tennessee, Chattanooga, TN 37403 USA
| |
Collapse
|
3
|
Wu D, Karimi-Maleh H, Liu X, Fu L. Bibliometrics Analysis of Research Progress of Electrochemical Detection of Tetracycline Antibiotics. JOURNAL OF ANALYTICAL METHODS IN CHEMISTRY 2023; 2023:6443610. [PMID: 36852208 PMCID: PMC9966827 DOI: 10.1155/2023/6443610] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 07/16/2022] [Revised: 09/27/2022] [Accepted: 10/07/2022] [Indexed: 06/18/2023]
Abstract
Tetracycline is a broad-spectrum class of antibiotics. The use of excessive doses of tetracycline antibiotics can result in their residues in food, posing varying degrees of risk to human health. Therefore, the establishment of a rapid and sensitive field detection method for tetracycline residues is of great practical importance to improve the safety of food-derived animal foods. Electrochemical analysis techniques are widely used in the field of pollutant detection because of the simple detection principle, easy operation of the instrument, and low cost of analysis. In this review, we summarize the electrochemical detection of tetracycline antibiotics by bibliometrics. Unlike the previously published reviews, this article reviews and analyzes the development of this topic. The contributions of different countries and different institutions were analyzed. Keyword analysis was used to explain the development of different research directions. The results of the analysis revealed that developments and innovations in materials science can enhance the performance of electrochemical detection of tetracycline antibiotics. Among them, gold nanoparticles and carbon nanotubes are the most used nanomaterials. Aptamer sensing strategies are the most favored methodologies in electrochemical detection of tetracycline antibiotics.
Collapse
Affiliation(s)
- Dihua Wu
- College of Materials and Environmental Engineering, Hangzhou Dianzi University, Hangzhou 310018, China
| | - Hassan Karimi-Maleh
- School of Resources and Environment, University of Electronic Science and Technology of China, P.O. Box 611731, Xiyuan Ave, Chengdu 610056, China
- Department of Chemical Engineering and Energy, Laboratory of Nanotechnology, Quchan University of Technology, Quchan 94771-67335, Iran
- Department of Chemical Sciences, University of Johannesburg, Doornfontein Campus, P.O. Box 17011, Johannesburg 2028, South Africa
| | - Xiaozhu Liu
- Department of Cardiology, The Second Affiliated Hospital of Chongqing Medical University, Chongqing 400010, China
| | - Li Fu
- College of Materials and Environmental Engineering, Hangzhou Dianzi University, Hangzhou 310018, China
| |
Collapse
|
4
|
Hashem A, Hossain MAM, Marlinda AR, Mamun MA, Sagadevan S, Shahnavaz Z, Simarani K, Johan MR. Nucleic acid-based electrochemical biosensors for rapid clinical diagnosis: advances, challenges, and opportunities. Crit Rev Clin Lab Sci 2022. [PMID: 34851806 DOI: 10.1016/j.apsadv.2021.100064] [Citation(s) in RCA: 39] [Impact Index Per Article: 13.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 05/15/2023]
Abstract
Clinical diagnostic tests should be quick, reliable, simple to perform, and affordable for diagnosis and treatment of diseases. In this regard, owing to their novel properties, biosensors have attracted the attention of scientists as well as end-users. They are efficient, stable, and relatively cheap. Biosensors have broad applications in medical diagnosis, including point-of-care (POC) monitoring, forensics, and biomedical research. The electrochemical nucleic acid (NA) biosensor, the latest invention in this field, combines the sensitivity of electroanalytical methods with the inherent bioselectivity of deoxyribonucleic acid (DNA) and ribonucleic acid (RNA). The NA biosensor exploits the affinity of single-stranded DNA/RNA for its complementary strand and is used to detect complementary sequences of NA based on hybridization. After the NA component in the sensor detects the analyte, a catalytic reaction or binding event that generates an electrical signal in the transducer ensues. Since 2000, much progress has been made in this field, but there are still numerous challenges. This critical review describes the advances, challenges, and prospects of NA-based electrochemical biosensors for clinical diagnosis. It includes the basic principles, classification, sensing enhancement strategies, and applications of biosensors as well as their advantages, limitations, and future prospects, and thus it should be useful to academics as well as industry in the improvement and application of EC NA biosensors.
Collapse
Affiliation(s)
- Abu Hashem
- Nanotechnology and Catalysis Research Centre, Institute for Advanced Studies, University of Malaya, Kuala Lumpur, Malaysia
- Microbial Biotechnology Division, National Institute of Biotechnology, Dhaka, Bangladesh
| | - M A Motalib Hossain
- Nanotechnology and Catalysis Research Centre, Institute for Advanced Studies, University of Malaya, Kuala Lumpur, Malaysia
| | - Ab Rahman Marlinda
- Nanotechnology and Catalysis Research Centre, Institute for Advanced Studies, University of Malaya, Kuala Lumpur, Malaysia
| | - Mohammad Al Mamun
- Nanotechnology and Catalysis Research Centre, Institute for Advanced Studies, University of Malaya, Kuala Lumpur, Malaysia
- Department of Chemistry, Jagannath University, Dhaka, Bangladesh
| | - Suresh Sagadevan
- Nanotechnology and Catalysis Research Centre, Institute for Advanced Studies, University of Malaya, Kuala Lumpur, Malaysia
| | - Zohreh Shahnavaz
- Nanotechnology and Catalysis Research Centre, Institute for Advanced Studies, University of Malaya, Kuala Lumpur, Malaysia
| | - Khanom Simarani
- Department of Microbiology, Institute of Biological Sciences, Faculty of Sciences, University of Malaya, Kuala Lumpur, Malaysia
| | - Mohd Rafie Johan
- Nanotechnology and Catalysis Research Centre, Institute for Advanced Studies, University of Malaya, Kuala Lumpur, Malaysia
| |
Collapse
|
5
|
Motshakeri M, Sharma M, Phillips ARJ, Kilmartin PA. Electrochemical Methods for the Analysis of Milk. JOURNAL OF AGRICULTURAL AND FOOD CHEMISTRY 2022; 70:2427-2449. [PMID: 35188762 DOI: 10.1021/acs.jafc.1c06350] [Citation(s) in RCA: 21] [Impact Index Per Article: 7.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/08/2023]
Abstract
The milk and dairy industries are some of the most profitable sectors in many countries. This business requires close control of product quality and continuous testing to ensure the safety of the consumers. The potential risk of contaminants or degradation products and undesirable chemicals necessitates the use of fast, reliable detection tools to make immediate production decisions. This review covers studies on the application of electrochemical methods to milk (i.e., voltammetric and amperometric) to quantify different analytes, as reported over the last 10 to 15 years. The review covers a wide range of analytes, including allergens, antioxidants, organic compounds, nitrogen- and aldehyde containing compounds, biochemicals, heavy metals, hydrogen peroxide, nitrite, and endocrine disruptors. The review also examines pretreatment procedures applied to milk samples and the use of novel sensor materials. Final perspectives are provided on the future of cost-effective and easy-to-use electrochemical sensors and their advantages over conventional methods.
Collapse
Affiliation(s)
- Mahsa Motshakeri
- Polymer Biointerface Centre, School of Chemical Sciences, University of Auckland, Private Bag 92019, Auckland, New Zealand
| | - Manisha Sharma
- School of Pharmacy, Faculty of Medical and Health Sciences, University of Auckland, 85 Park Road, Grafton, Auckland 1023, New Zealand
| | - Anthony R J Phillips
- School of Biological Sciences, University of Auckland, Private Bag, 92019 Auckland, New Zealand
| | - Paul A Kilmartin
- Polymer Biointerface Centre, School of Chemical Sciences, University of Auckland, Private Bag 92019, Auckland, New Zealand
| |
Collapse
|
6
|
Raykova MR, Corrigan DK, Holdsworth M, Henriquez FL, Ward AC. Emerging Electrochemical Sensors for Real-Time Detection of Tetracyclines in Milk. BIOSENSORS 2021; 11:232. [PMID: 34356702 PMCID: PMC8301834 DOI: 10.3390/bios11070232] [Citation(s) in RCA: 12] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 05/27/2021] [Revised: 06/29/2021] [Accepted: 07/07/2021] [Indexed: 12/12/2022]
Abstract
Antimicrobial drug residues in food are strictly controlled and monitored by national laws in most territories. Tetracyclines are a major broad-spectrum antibiotic class, active against a wide range of Gram-positive and Gram-negative bacteria, and they are the leading choice for the treatment of many conditions in veterinary medicine in recent years. In dairy farms, milk from cows being treated with antibiotic drugs, such as tetracyclines, is considered unfit for human consumption. Contamination of the farm bulk tank with milk containing these residues presents a threat to confidence of supply and results in financial losses to farmers and dairy. Real-time monitoring of milk production for antimicrobial residues could reduce this risk and help to minimise the release of residues into the environment where they can cause reservoirs of antimicrobial resistance. In this article, we review the existing literature for the detection of tetracyclines in cow's milk. Firstly, the complex nature of the milk matrix is described, and the test strategies in commercial use are outlined. Following this, emerging biosensors in the low-cost biosensors field are contrasted against each other, focusing upon electrochemical biosensors. Existing commercial tests that identify antimicrobial residues within milk are largely limited to beta-lactam detection, or non-specific detection of microbial inhibition, with tests specific to tetracycline residues less prevalent. Herein, we review a number of emerging electrochemical biosensor detection strategies for tetracyclines, which have the potential to close this gap and address the industry challenges associated with existing tests.
Collapse
Affiliation(s)
- Magdalena R Raykova
- Civil and Environmental Engineering, University of Strathclyde, Glasgow G1 1XJ, UK
| | - Damion K Corrigan
- Biomedical Engineering, University of Strathclyde, Glasgow G1 1QE, UK
| | - Morag Holdsworth
- Graham's Dairy Family, Bridge of Allan, Stirling, Glasgow FK9 4RW, UK
| | - Fiona L Henriquez
- School of Health and Life Sciences, University of the West of Scotland, Paisley PA1 2BE, UK
| | - Andrew C Ward
- Civil and Environmental Engineering, University of Strathclyde, Glasgow G1 1XJ, UK
| |
Collapse
|
7
|
Wang S, Yan X, Yang Y, Qi X, Zhao Y, Li L, Ma R, Wang L, Dong Y, Sun J, Mao X. Advances and perspectives of aptasensors for the detection of tetracyclines: A class of model compounds of food analysis. Food Chem 2021; 364:130361. [PMID: 34153597 DOI: 10.1016/j.foodchem.2021.130361] [Citation(s) in RCA: 24] [Impact Index Per Article: 6.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/30/2020] [Revised: 05/24/2021] [Accepted: 05/25/2021] [Indexed: 10/21/2022]
Abstract
The residual tetracyclines in food are frequently applied as the model compounds to develop aptasensors. Until now, more than 100 advanced aptasensors towards tetracyclines have been developed and published in English. This review summarizes and discusses comprehensively these advanced aptasensors, in terms of the principle designs, applied frontier transducers/materials, working performance, and advantages/disadvantages. The aptasensors are classified according to the inherent transduction techniques, i.e., optics, optics-electricity, optics-mass, and electricity-mass. Moreover, the present challenges such as the limited specificity and limited affinity of the aptamers, the future prospects and trends such as further combination with other advanced materials and technologies, and the urgent need of expanding the practical application were discussed and prospected. We hope this review can serve as a powerful tool for both tracing the development progresses of aptasensors and providing adequate references for further development of aptasensing methods for food-related analytes.
Collapse
Affiliation(s)
- Sai Wang
- College of Food Science and Engineering, Ocean University of China, Qingdao, Shandong Province 266003, China
| | - Xiaochen Yan
- College of Food Science and Engineering, Ocean University of China, Qingdao, Shandong Province 266003, China
| | - Yan Yang
- College of Life Science and Technology, Beijing University of Chemical Technology, Beijing 100029, China
| | - Xiaoyan Qi
- College of Food Science and Engineering, Ocean University of China, Qingdao, Shandong Province 266003, China
| | - Yinglin Zhao
- College of Food Science and Engineering, Ocean University of China, Qingdao, Shandong Province 266003, China
| | - Ling Li
- College of Food Science and Engineering, Ocean University of China, Qingdao, Shandong Province 266003, China
| | - Rui Ma
- College of Food Science and Engineering, Ocean University of China, Qingdao, Shandong Province 266003, China
| | - Lele Wang
- College of Food Science and Engineering, Ocean University of China, Qingdao, Shandong Province 266003, China
| | - Yiyang Dong
- College of Life Science and Technology, Beijing University of Chemical Technology, Beijing 100029, China.
| | - Jianan Sun
- College of Food Science and Engineering, Ocean University of China, Qingdao, Shandong Province 266003, China.
| | - Xiangzhao Mao
- College of Food Science and Engineering, Ocean University of China, Qingdao, Shandong Province 266003, China; Laboratory for Marine Drugs and Bioproducts of Qingdao National Laboratory for Marine Science and Technology, Qingdao, Shandong Province 266237, China
| |
Collapse
|
8
|
Marques AC, Pinheiro T, Martins GV, Cardoso AR, Martins R, Sales MG, Fortunato E. Non-enzymatic lab-on-paper devices for biosensing applications. COMPREHENSIVE ANALYTICAL CHEMISTRY 2020. [DOI: 10.1016/bs.coac.2020.05.001] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 12/17/2022]
|
9
|
Yan Z, Yi H, Wang L, Zhou X, Yan R, Zhang D, Wang S, Su L, Zhou S. Fluorescent aptasensor for ofloxacin detection based on the aggregation of gold nanoparticles and its effect on quenching the fluorescence of Rhodamine B. SPECTROCHIMICA ACTA. PART A, MOLECULAR AND BIOMOLECULAR SPECTROSCOPY 2019; 221:117203. [PMID: 31174139 DOI: 10.1016/j.saa.2019.117203] [Citation(s) in RCA: 15] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 03/30/2019] [Revised: 05/26/2019] [Accepted: 05/26/2019] [Indexed: 06/09/2023]
Abstract
This paper proposes the idea of building a fluorescent biosensor for ofloxacin (OFL) determination in aqueous and milk samples by label-free OFL-specific aptamer, gold nanoparticles (AuNPs) and Rhodamine B (RB). In the absence of OFL, AuNPs are coated with OFL aptamer and maintain dispersed in the high concentration of NaCl. The dispersed AuNPs could reduce the strong fluorescence intensity of RB efficiently. By contrast, in the presence of OFL, OFL is combined with aptamer to form stable compounds, causing the aptamers separated from the surface of AuNPs, thus AuNPs would be exposed in the solution. And the aggregated AuNPs will not quench the fluorescence intensity of RB. Through the distinction of the fluorescence intensity, the concentration of OFL could be detected in aqueous and milk samples quantitatively. The convenient and specific fluorescent assay for OFL is established with a linear range (R = 0.9907) from 20 to 300 nM and a detection limit of 1.66 nM in aqueous solution, and a linear range (R = 0.9963) from 20 to 300 nM and a detection limit of 4.61 nM (1.66 μg/L) in milk samples. With the good sensitivity and selectivity, this biosensor has good application potential to detect OFL in food and environmental samples.
Collapse
Affiliation(s)
- Zhiyu Yan
- School of Agriculture and Biology, Key Laboratory of Urban Agriculture, Ministry of Agriculture, Bor S. Luh Food Safety Research Center, Shanghai Jiao Tong University, Shanghai 200240, PR China
| | - Haoyang Yi
- School of Agriculture and Biology, Key Laboratory of Urban Agriculture, Ministry of Agriculture, Bor S. Luh Food Safety Research Center, Shanghai Jiao Tong University, Shanghai 200240, PR China
| | - Lumei Wang
- School of Agriculture and Biology, Key Laboratory of Urban Agriculture, Ministry of Agriculture, Bor S. Luh Food Safety Research Center, Shanghai Jiao Tong University, Shanghai 200240, PR China.
| | - Xiaotong Zhou
- School of Agriculture and Biology, Key Laboratory of Urban Agriculture, Ministry of Agriculture, Bor S. Luh Food Safety Research Center, Shanghai Jiao Tong University, Shanghai 200240, PR China
| | - Rui Yan
- Meteorological Bureau of Liupanshui, Liupanshui 553000, PR China
| | - Dongwei Zhang
- School of Agriculture and Biology, Key Laboratory of Urban Agriculture, Ministry of Agriculture, Bor S. Luh Food Safety Research Center, Shanghai Jiao Tong University, Shanghai 200240, PR China
| | - Song Wang
- School of Agriculture and Biology, Key Laboratory of Urban Agriculture, Ministry of Agriculture, Bor S. Luh Food Safety Research Center, Shanghai Jiao Tong University, Shanghai 200240, PR China
| | - Lantian Su
- School of Agriculture and Biology, Key Laboratory of Urban Agriculture, Ministry of Agriculture, Bor S. Luh Food Safety Research Center, Shanghai Jiao Tong University, Shanghai 200240, PR China
| | - Shanshan Zhou
- College of Environment, Zhejiang University of Technology, Hangzhou 310014, PR China
| |
Collapse
|
10
|
Rouhbakhsh Z, Verdian A, Rajabzadeh G. Design of a liquid crystal-based aptasensing platform for ultrasensitive detection of tetracycline. Talanta 2019; 206:120246. [PMID: 31514901 DOI: 10.1016/j.talanta.2019.120246] [Citation(s) in RCA: 35] [Impact Index Per Article: 5.8] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/02/2019] [Revised: 08/04/2019] [Accepted: 08/08/2019] [Indexed: 02/06/2023]
Abstract
We develop a novel label-free liquid crystal (LC) aptasensor based on intrinsic properties of nematic LCs for ultra-sensitive detection of tetracycline. The aptasensor is assembled by immobilizing aptamers onto the glass slide modified with both homeotropic alignment and silane coupling agents. Designed aptasensor makes use of the target-induced aptamer conformational switching and disruption of the orientation of LCs which lead to an obvious change of the optical appearance from a dark to a bright response. We describe the optimized condition for maintaining the homeotropic orientation of LCs, which are suitable for the tetracycline detection. The average gray-scale intensities of polarizing optical microscopy images were calculated to quantitatively detect tetracycline concentrations. The aptasensor works especially at trace level of tetracycline as low as 0.5 pM. Moreover, the LC aptasensor was successfully used to detect tetracycline in the real milk sample. According to the results, the proposed LC aptasensor for tetracycline detection is simple, ultra-sensitive, label free and ease of preparation.
Collapse
Affiliation(s)
- Zeinab Rouhbakhsh
- Department of Food Safety and Quality Control, Research Institute of Food Science and Technology (RIFST), Mashhad, Iran
| | - Asma Verdian
- Department of Food Safety and Quality Control, Research Institute of Food Science and Technology (RIFST), Mashhad, Iran.
| | - Ghadir Rajabzadeh
- Department of Food Nanotechnology, Research Institute of Food Science and Technology (RIFST), Mashhad, Iran
| |
Collapse
|
11
|
Gong X, Li X, Qing T, Zhang P, Feng B. Amplified colorimetric detection of tetracycline based on an enzyme-linked aptamer assay with multivalent HRP-mimicking DNAzyme. Analyst 2019; 144:1948-1954. [PMID: 30694262 DOI: 10.1039/c8an02284d] [Citation(s) in RCA: 27] [Impact Index Per Article: 4.5] [Reference Citation Analysis] [Abstract] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/13/2022]
Abstract
Tetracycline (TC) is widely used to treat bacterial infections in humans and animals due to its low price and good antibacterial properties. The abuse of tetracycline has led to TC residues in daily food that could seriously affect human health. Thus, it is imperative to develop highly sensitive and selective methods for TC detection. In this work, we developed a colorimetric method for TC detection based on an enzyme-linked aptamer assay (ELAA) with multivalent HRP-mimicking DNAzyme. An aptamer was used as an alternative recognition element in the enzyme-linked immunosorbent assay (ELISA). Multivalent HRP-mimicking DNAzyme, assembled via hybridization chain reactions (HCR), was used for catalytic substrate color rendering in ELAA. The multivalent HRP-mimicking DNAzyme exhibited enhanced catalytic capacity and improved the detection sensitivity greatly. The limit of detection was 8.1 × 10-2 ng mL-1 with a linear range from 1.0 × 10-2 ng mL-1 to 1.0 × 104 ng mL-1 toward TC in buffer. To challenge the practical application capability of this strategy, the detection of TC in milk samples was also investigated and showed similar linear relationships. Due to the introduction of an aptamer, this ELAA strategy shows high selectivity towards TC and has potential for the detection of a wide spectrum of analytes.
Collapse
Affiliation(s)
- Xin Gong
- College of Chemical Engineering, Xiangtan University, Xiangtan 411105, Hunan Province, China
| | | | | | | | | |
Collapse
|
12
|
Screening of Oligonucleotide Aptamers and Application in Detection of Pesticide and Veterinary Drug Residues. CHINESE JOURNAL OF ANALYTICAL CHEMISTRY 2019. [DOI: 10.1016/s1872-2040(19)61153-9] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 02/07/2023]
|
13
|
Hanif A, Farooq R, Rehman MU, Khan R, Majid S, Ganaie MA. Aptamer based nanobiosensors: Promising healthcare devices. Saudi Pharm J 2019; 27:312-319. [PMID: 30976173 PMCID: PMC6438676 DOI: 10.1016/j.jsps.2018.11.013] [Citation(s) in RCA: 23] [Impact Index Per Article: 3.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/28/2018] [Accepted: 11/22/2018] [Indexed: 12/20/2022] Open
Abstract
Nanobiosensors based on aptamer are extensively being studied as potent analytical tools in clinical analysis. These biosensors provide high sensitivity, fast response, specificity and desired portability in addition to simplicity and decreased cost compared to conventional methods. The purpose of this manuscript is to provide readers with an overview of current advances about electrochemical, electrochemiluminescent and photoelectrochemical aptasensors from the sea of available literature. These are mainly used for determination of protein-based biomarkers, especially for cancer diagnosis. Here in we have given special emphasis on nanosize-based aptasensors which have been reported to show considerable improvement in the analytical performance.
Collapse
Affiliation(s)
- Aamir Hanif
- City University of Hong Kong, Tat Chee Avenue, Kowloon, Hong Kong Special Administrative Region
| | - Rabia Farooq
- Department of Biochemistry, Govt Medical College (GMC) Srinagar, J&K 190010, India
| | - Muneeb U. Rehman
- Department of Biochemistry, Govt Medical College (GMC) Srinagar, J&K 190010, India
| | - Rehan Khan
- Nanotherapeutics, Institute of Nanoscience & Technology (DST-INST), Habitat Centre Phase 10, Mohali, Punjab, India
| | - Sabhiya Majid
- Department of Biochemistry, Govt Medical College (GMC) Srinagar, J&K 190010, India
| | - Majid Ahmad Ganaie
- Department of Pharmacology, College of Pharmacy, Prince Sattam Bin Abdulaziz University, Al-Kharj 11942, Saudi Arabia
| |
Collapse
|
14
|
|
15
|
Jaeger J, Groher F, Stamm J, Spiehl D, Braun J, Dörsam E, Suess B. Characterization and Inkjet Printing of an RNA Aptamer for Paper-Based Biosensing of Ciprofloxacin. BIOSENSORS 2019; 9:E7. [PMID: 30609709 PMCID: PMC6468496 DOI: 10.3390/bios9010007] [Citation(s) in RCA: 16] [Impact Index Per Article: 2.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 11/26/2018] [Revised: 12/24/2018] [Accepted: 12/26/2018] [Indexed: 12/25/2022]
Abstract
The excessive use of antibiotics in food-producing animals causes a steady rise of multiple antibiotic resistance in foodborne bacteria. Next to sulfonamides, the most common antibiotics groups are fluoroquinolones, aminoglycosides, and ß-lactams. Therefore, there is a need for a quick, efficient, and low-cost detection procedure for antibiotics. In this study, we propose an inkjet-printed aptamer-based biosensor developed for the detection of the fluoroquinolone ciprofloxacin. Due to their extraordinary high affinity and specificity, aptamers are already widely used in various applications. Here we present a ciprofloxacin-binding RNA aptamer developed by systematic evolution of ligands by exponential enrichment (SELEX). We characterized the secondary structure of the aptamer and determined the KD to 36 nM that allow detection of antibiotic contamination in a relevant range. We demonstrate that RNA aptamers can be inkjet-printed, dried, and resolved while keeping their functionality consistently intact. With this proof of concept, we are paving the way for a potential range of additional aptamer-based, printable biosensors.
Collapse
Affiliation(s)
- Jeannine Jaeger
- Department of Biology, Technische Universität Darmstadt, 64287 Darmstadt, Germany.
| | - Florian Groher
- Department of Biology, Technische Universität Darmstadt, 64287 Darmstadt, Germany.
| | - Jacqueline Stamm
- Institute for Printing Science and Technology, Technische Universität Darmstadt, 64289 Darmstadt, Germany.
| | - Dieter Spiehl
- Institute for Printing Science and Technology, Technische Universität Darmstadt, 64289 Darmstadt, Germany.
| | - Johannes Braun
- Department of Biology, Technische Universität Darmstadt, 64287 Darmstadt, Germany.
| | - Edgar Dörsam
- Institute for Printing Science and Technology, Technische Universität Darmstadt, 64289 Darmstadt, Germany.
| | - Beatrix Suess
- Department of Biology, Technische Universität Darmstadt, 64287 Darmstadt, Germany.
| |
Collapse
|
16
|
Duan N, Wu S, Dai S, Gu H, Hao L, Ye H, Wang Z. Advances in aptasensors for the detection of food contaminants. Analyst 2018; 141:3942-61. [PMID: 27265444 DOI: 10.1039/c6an00952b] [Citation(s) in RCA: 89] [Impact Index Per Article: 12.7] [Reference Citation Analysis] [Abstract] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/16/2022]
Abstract
Food safety is a global health objective, and foodborne diseases represent a major crisis in health. Techniques that are simple and suitable for fast screening to detect and identify pathogenic factors in the food chain are vital to ensure food safety. At present, a variety of analytical methods have been reported for the detection of pathogenic agents. Whereas the sensitivity of detection and quantification are still important challenges, we expect major advances from new assay formats and synthetic bio-recognition elements, such as aptamers. Owing to the specific folding capability of aptamers in the presence of an analyte, aptasensors have substantially and successfully been exploited for the detection of a wide range of small and large molecules (e.g., toxins, antibiotics, heavy metals, bacteria, viruses) at very low concentrations. Here, we review the use of aptasensors for the development of highly sensitive and affordable detection tools for food analysis.
Collapse
Affiliation(s)
- Nuo Duan
- State Key Laboratory of Food Science and Technology, School of Food Science and Technology, Jiangnan University, Wuxi 214122, China.
| | - Shijia Wu
- State Key Laboratory of Food Science and Technology, School of Food Science and Technology, Jiangnan University, Wuxi 214122, China.
| | - Shaoliang Dai
- State Key Laboratory of Food Science and Technology, School of Food Science and Technology, Jiangnan University, Wuxi 214122, China.
| | - Huajie Gu
- State Key Laboratory of Food Science and Technology, School of Food Science and Technology, Jiangnan University, Wuxi 214122, China.
| | - Liling Hao
- State Key Laboratory of Food Science and Technology, School of Food Science and Technology, Jiangnan University, Wuxi 214122, China.
| | - Hua Ye
- State Key Laboratory of Food Science and Technology, School of Food Science and Technology, Jiangnan University, Wuxi 214122, China.
| | - Zhouping Wang
- State Key Laboratory of Food Science and Technology, School of Food Science and Technology, Jiangnan University, Wuxi 214122, China.
| |
Collapse
|
17
|
Mehlhorn A, Rahimi P, Joseph Y. Aptamer-Based Biosensors for Antibiotic Detection: A Review. BIOSENSORS-BASEL 2018; 8:bios8020054. [PMID: 29891818 PMCID: PMC6023021 DOI: 10.3390/bios8020054] [Citation(s) in RCA: 124] [Impact Index Per Article: 17.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 04/26/2018] [Revised: 06/04/2018] [Accepted: 06/05/2018] [Indexed: 02/06/2023]
Abstract
Antibiotic resistance and, accordingly, their pollution because of uncontrolled usage has emerged as a serious problem in recent years. Hence, there is an increased demand to develop robust, easy, and sensitive methods for rapid evaluation of antibiotics and their residues. Among different analytical methods, the aptamer-based biosensors (aptasensors) have attracted considerable attention because of good selectivity, specificity, and sensitivity. This review gives an overview about recently-developed aptasensors for antibiotic detection. The use of various aptamer assays to determine different groups of antibiotics, like β-lactams, aminoglycosides, anthracyclines, chloramphenicol, (fluoro)quinolones, lincosamide, tetracyclines, and sulfonamides are presented in this paper.
Collapse
Affiliation(s)
- Asol Mehlhorn
- Institute of Electronic and Sensory Materials, Faculty of Materials Science and Materials Technology, Technological University Freiberg, Akademie Str. 6, 09599 Freiberg, Germany.
| | - Parvaneh Rahimi
- Institute of Electronic and Sensory Materials, Faculty of Materials Science and Materials Technology, Technological University Freiberg, Akademie Str. 6, 09599 Freiberg, Germany.
| | - Yvonne Joseph
- Institute of Electronic and Sensory Materials, Faculty of Materials Science and Materials Technology, Technological University Freiberg, Akademie Str. 6, 09599 Freiberg, Germany.
| |
Collapse
|
18
|
Pérez-Rodríguez M, Pellerano RG, Pezza L, Pezza HR. An overview of the main foodstuff sample preparation technologies for tetracycline residue determination. Talanta 2018; 182:1-21. [DOI: 10.1016/j.talanta.2018.01.058] [Citation(s) in RCA: 57] [Impact Index Per Article: 8.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/29/2017] [Revised: 01/19/2018] [Accepted: 01/20/2018] [Indexed: 12/26/2022]
|
19
|
Jalalian SH, Karimabadi N, Ramezani M, Abnous K, Taghdisi SM. Electrochemical and optical aptamer-based sensors for detection of tetracyclines. Trends Food Sci Technol 2018. [DOI: 10.1016/j.tifs.2018.01.009] [Citation(s) in RCA: 77] [Impact Index Per Article: 11.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/27/2022]
|
20
|
Zhan X, Hu G, Wagberg T, Zhang D, Zhou P. A Label-Free Electrochemical Aptasensor for the Rapid Detection of Tetracycline Based on Ordered Mesoporous Carbon–Fe3O4. Aust J Chem 2018. [DOI: 10.1071/ch17503] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/23/2022]
Abstract
A novel aptasensor based on a tetracycline (TET) aptamer immobilized by physical adsorption on an ordered mesoporous carbon–Fe3O4 (OMC-Fe3O4)-modified screen-printed electrode surface was successfully fabricated. OMC-Fe3O4 was characterized by scanning electron microscopy, X-ray diffraction, and X-ray photoelectron spectroscopy. The modification procedure of the aptasensor was characterized by cyclic voltammetry. Interaction between the TET aptamer and target was determined by differential pulse voltammetry. Under optimal conditions, the proposed aptasensor exhibited good electrochemical sensitivity to TET in a concentration range of 5 nM to 10 μM, with a detection limit of 0.8 nM (S/N = 3). This aptasensor exhibited satisfactory specificity, reproducibility, and stability.
Collapse
|
21
|
Application of aptamers in detection and chromatographic purification of antibiotics in different matrices. Trends Analyt Chem 2017. [DOI: 10.1016/j.trac.2017.07.023] [Citation(s) in RCA: 35] [Impact Index Per Article: 4.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/19/2022]
|
22
|
Majdinasab M, Yaqub M, Rahim A, Catanante G, Hayat A, Marty JL. An Overview on Recent Progress in Electrochemical Biosensors for Antimicrobial Drug Residues in Animal-Derived Food. SENSORS (BASEL, SWITZERLAND) 2017; 17:E1947. [PMID: 28837093 PMCID: PMC5621119 DOI: 10.3390/s17091947] [Citation(s) in RCA: 30] [Impact Index Per Article: 3.8] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 07/18/2017] [Revised: 08/09/2017] [Accepted: 08/22/2017] [Indexed: 12/21/2022]
Abstract
Anti-microbial drugs are widely employed for the treatment and cure of diseases in animals, promotion of animal growth, and feed efficiency. However, the scientific literature has indicated the possible presence of antimicrobial drug residues in animal-derived food, making it one of the key public concerns for food safety. Therefore, it is highly desirable to design fast and accurate methodologies to monitor antimicrobial drug residues in animal-derived food. Legislation is in place in many countries to ensure antimicrobial drug residue quantities are less than the maximum residue limits (MRL) defined on the basis of food safety. In this context, the recent years have witnessed a special interest in the field of electrochemical biosensors for food safety, based on their unique analytical features. This review article is focused on the recent progress in the domain of electrochemical biosensors to monitor antimicrobial drug residues in animal-derived food.
Collapse
Affiliation(s)
- Marjan Majdinasab
- Department of Food Science & Technology, Shiraz University, Shiraz 71441-65186, Iran.
| | - Mustansara Yaqub
- Interdisciplinary Research Centre in Biomedical Materials (IRCBM), COMSATS Institute of Information Technology, Lahore 54000, Pakistan.
| | - Abdur Rahim
- Interdisciplinary Research Centre in Biomedical Materials (IRCBM), COMSATS Institute of Information Technology, Lahore 54000, Pakistan.
| | - Gaelle Catanante
- BAE: Biocapteurs-Analyses-Environnement, Universite de Perpignan Via Domitia, 52 Avenue Paul Alduy, Perpignan CEDEX 66860, France.
| | - Akhtar Hayat
- Interdisciplinary Research Centre in Biomedical Materials (IRCBM), COMSATS Institute of Information Technology, Lahore 54000, Pakistan.
| | - Jean Louis Marty
- BAE: Biocapteurs-Analyses-Environnement, Universite de Perpignan Via Domitia, 52 Avenue Paul Alduy, Perpignan CEDEX 66860, France.
| |
Collapse
|
23
|
Wang A, Zhao H, Chen X, Tan B, Zhang Y, Quan X. A colorimetric aptasensor for sulfadimethoxine detection based on peroxidase-like activity of graphene/nickel@palladium hybrids. Anal Biochem 2017; 525:92-99. [PMID: 28283448 DOI: 10.1016/j.ab.2017.03.006] [Citation(s) in RCA: 36] [Impact Index Per Article: 4.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/28/2016] [Revised: 03/02/2017] [Accepted: 03/06/2017] [Indexed: 12/17/2022]
Abstract
A sensitive, rapid and label-free colorimetric aptasensor for sulfadimethoxine (SDM) detection was developed based on the tunable peroxidase-like activity of graphene/nickel@palladium nanoparticle (Gr/Ni@Pd) hybrids. The addition of the SDM aptamer could inhibit the peroxidase-like catalytic activity of the hybrids. However, the target SDM and aptamer could be triggered tightly and recover the catalytic activity of the Gr/Ni@Pd hybrids. Due to the peroxidase-like catalytic activity, Gr/Ni@Pd could catalyze the decomposition of H2O2 with releasing hydroxyl radicals which further oxidized reagent 3, 3', 5, 5'-Tetramethylbenzidine (TMB) to oxTMB accompanied with a colorless-to-blue color change. The original color change could be applied to obtain quantitative detection of SDM, due to the relationship between the concentration of the target and the color difference. As a result, this approach performed a linear response for SDM from 1 to 500 ng/mL with a limit detection of 0.7 ng/mL (S/N = 3) under the optimized conditions and realized the detection of SDM in spiked lake water samples. Therefore, this colorimetric aptasensor was an alternative assay for SDM detection in real water. Moreover, with its design principle, this work might be applied to detecting other small molecule by employing appropriate aptamer.
Collapse
Affiliation(s)
- Aicheng Wang
- Key Laboratory of Industrial Ecology and Environmental Engineering (Ministry of Education, China), School of Environmental Science and Technology, Dalian University of Technology, Linggong Road 2, Dalian 116024, PR China
| | - Huimin Zhao
- Key Laboratory of Industrial Ecology and Environmental Engineering (Ministry of Education, China), School of Environmental Science and Technology, Dalian University of Technology, Linggong Road 2, Dalian 116024, PR China.
| | - Xiaochi Chen
- Key Laboratory of Industrial Ecology and Environmental Engineering (Ministry of Education, China), School of Environmental Science and Technology, Dalian University of Technology, Linggong Road 2, Dalian 116024, PR China; Department of Urology, The First Affiliated Hospital of Dalian Medical University, Zhongshan Road 222, Dalian 116027, PR China.
| | - Bing Tan
- Key Laboratory of Industrial Ecology and Environmental Engineering (Ministry of Education, China), School of Environmental Science and Technology, Dalian University of Technology, Linggong Road 2, Dalian 116024, PR China
| | - Yaobin Zhang
- Key Laboratory of Industrial Ecology and Environmental Engineering (Ministry of Education, China), School of Environmental Science and Technology, Dalian University of Technology, Linggong Road 2, Dalian 116024, PR China
| | - Xie Quan
- Key Laboratory of Industrial Ecology and Environmental Engineering (Ministry of Education, China), School of Environmental Science and Technology, Dalian University of Technology, Linggong Road 2, Dalian 116024, PR China
| |
Collapse
|
24
|
Meng F, Ma X, Duan N, Wu S, Xia Y, Wang Z, Xu B. Ultrasensitive SERS aptasensor for the detection of oxytetracycline based on a gold-enhanced nano-assembly. Talanta 2017; 165:412-418. [PMID: 28153276 DOI: 10.1016/j.talanta.2016.12.088] [Citation(s) in RCA: 43] [Impact Index Per Article: 5.4] [Reference Citation Analysis] [Abstract] [Key Words] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/28/2016] [Revised: 12/28/2016] [Accepted: 12/30/2016] [Indexed: 10/20/2022]
Abstract
This paper investigated a new detection method of oxytetracycline (OTC) in aquatic products with ultrasensitive detection limit. The method was constructed on the basis of raman hot spot between gold nanoparticles (AuNPs) (13nm and 80nm diameter respectively) linked by an DNA sequence. The DNA sequence combined with the OTC aptamer including its complementary sequence as well as a stem-loop structure. The raman signal molecule (4-MBA) was modified at the surface of 13nm AuNPs. After the exposure of OTC, the aptamer sequence was preferentially combined with OTC and partially dehybridized with its complementary sequence which led the 13nm AuNPs to get more closer to the 80nm AuNPs. The raman intensity was thus increased for the more enhanced hot spot generated. Under the optimal experimental conditions, the SERS signal was positively related to the OTC concentration with a wide working range of 4.60×10-2-4.60×102fg/mL and the limit of detection (LOD) was as low as 4.35×10-3fg/mL. The recovery rates of fishmeal ranged from 91.29-110.98%. The specificity of this method was further examined, and the results showed that the AuNPs based aptasensor was highly selective. This developed ultrasensitive aptamer-based SERS detection platform suggested that it may be a promising strategy for a variety of sensing applications.
Collapse
Affiliation(s)
- Fanwei Meng
- State Key Laboratory of Food Science and Technology, Synergetic Innovation Center of Food Safety and Nutrition, School of Food Science and Technology, Jiangnan University, Wuxi 214122, China
| | - Xiaoyuan Ma
- State Key Laboratory of Food Science and Technology, Synergetic Innovation Center of Food Safety and Nutrition, School of Food Science and Technology, Jiangnan University, Wuxi 214122, China
| | - Nuo Duan
- State Key Laboratory of Food Science and Technology, Synergetic Innovation Center of Food Safety and Nutrition, School of Food Science and Technology, Jiangnan University, Wuxi 214122, China
| | - Shijia Wu
- State Key Laboratory of Food Science and Technology, Synergetic Innovation Center of Food Safety and Nutrition, School of Food Science and Technology, Jiangnan University, Wuxi 214122, China
| | - Yu Xia
- State Key Laboratory of Food Science and Technology, Synergetic Innovation Center of Food Safety and Nutrition, School of Food Science and Technology, Jiangnan University, Wuxi 214122, China
| | - Zhouping Wang
- State Key Laboratory of Food Science and Technology, Synergetic Innovation Center of Food Safety and Nutrition, School of Food Science and Technology, Jiangnan University, Wuxi 214122, China.
| | - Baocai Xu
- State Key Lab Meat Processing & Quality Control, Yurun Group, Nanjing 210041, Jiangsu, China
| |
Collapse
|
25
|
Goh E, Lee HJ. Development Trend of Biosensors for Antimicrobial Drugs in Water Environment. APPLIED CHEMISTRY FOR ENGINEERING 2016. [DOI: 10.14478/ace.2016.1107] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/22/2022]
|
26
|
An aptamer based assay for the β-adrenergic agonist ractopamine based on aggregation of gold nanoparticles in combination with a molecularly imprinted polymer. Mikrochim Acta 2016. [DOI: 10.1007/s00604-016-1913-5] [Citation(s) in RCA: 16] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/17/2022]
|
27
|
Pfeiffer F, Mayer G. Selection and Biosensor Application of Aptamers for Small Molecules. Front Chem 2016; 4:25. [PMID: 27379229 PMCID: PMC4908669 DOI: 10.3389/fchem.2016.00025] [Citation(s) in RCA: 153] [Impact Index Per Article: 17.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/31/2016] [Accepted: 05/30/2016] [Indexed: 12/12/2022] Open
Abstract
Small molecules play a major role in the human body and as drugs, toxins, and chemicals. Tools to detect and quantify them are therefore in high demand. This review will give an overview about aptamers interacting with small molecules and their selection. We discuss the current state of the field, including advantages as well as problems associated with their use and possible solutions to tackle these. We then discuss different kinds of small molecule aptamer-based sensors described in literature and their applications, ranging from detecting drinking water contaminations to RNA imaging.
Collapse
Affiliation(s)
- Franziska Pfeiffer
- Department of Chemical Biology, Life and Medical Sciences Institute, University of Bonn Bonn, Germany
| | - Günter Mayer
- Department of Chemical Biology, Life and Medical Sciences Institute, University of Bonn Bonn, Germany
| |
Collapse
|
28
|
Jiang HP, Zhu JX, Peng C, Gao J, Zheng F, Xiao YX, Feng YQ, Yuan BF. Facile one-pot synthesis of a aptamer-based organic-silica hybrid monolithic capillary column by "thiol-ene" click chemistry for detection of enantiomers of chemotherapeutic anthracyclines. Analyst 2015; 139:4940-6. [PMID: 25072056 DOI: 10.1039/c4an00767k] [Citation(s) in RCA: 39] [Impact Index Per Article: 3.9] [Reference Citation Analysis] [Abstract] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/21/2022]
Abstract
In the current study, we developed a facile strategy for the one-pot synthesis of an aptamer-based organic-silica hybrid monolithic capillary column. A 5'-SH-modified aptamer, specifically targeting doxorubicin, was covalently modified in the hybrid silica monolithic column by a sol-gel method combined with "thiol-ene" click reaction. The prepared monolithic column had good stability and permeability, large specific surface, and showed excellent selectivity towards chemotherapeutic anthracyclines of doxorubicin and epirubicin. In addition, the enantiomers of doxorubicin and epirubicin can be easily separated by aptamer-based affinity monolithic capillary liquid chromatography. Furthermore, doxorubicin and epirubicin spiked in serum and urine were also successfully determined, which suggested that the complex biological matrix had a negligible effect on the detection of doxorubicin and epirubicin. Finally, we quantified the concentration of epirubicin in the serum of breast cancer patients treated with epirubicin by intravenous injection. The developed analytical method is cost-effective and rapid, and biological samples can be directly analyzed without any tedious sample pretreatment, which is extremely useful for monitoring medicines in serum and urine for pharmacokinetic studies.
Collapse
Affiliation(s)
- Han-Peng Jiang
- Key Laboratory of Analytical Chemistry for Biology and Medicine (Ministry of Education), Department of Chemistry, Wuhan University, Wuhan 430072, China.
| | | | | | | | | | | | | | | |
Collapse
|
29
|
Udalova AY, Dmitrienko SG, Apyari VV. Methods for the separation, preconcentration, and determination of tetracycline antibiotics. JOURNAL OF ANALYTICAL CHEMISTRY 2015. [DOI: 10.1134/s1061934815060180] [Citation(s) in RCA: 20] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/23/2022]
|
30
|
Aptamer-based technology for food analysis. Appl Biochem Biotechnol 2014; 175:603-24. [PMID: 25338114 DOI: 10.1007/s12010-014-1289-0] [Citation(s) in RCA: 36] [Impact Index Per Article: 3.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/27/2014] [Accepted: 10/06/2014] [Indexed: 02/07/2023]
Abstract
Aptamers are short and functional single-stranded oligonucleotide sequences selected from systematic evolution of ligands by exponential enrichment (SELEX) process, which have the capacity to recognize various classes of target molecules with high affinity and specificity. Various analytical aptamers acquired by SELEX are widely used in many research fields, such as medicine, biology, and chemistry. However, the application of this innovative and emerging technology to food safety is just in infant stage. Food safety plays a very important role in our daily lives because varieties of poisonous and harmful substances in food affect human health. Aptamer technique is promising, which can overcome many disadvantages of existing detection methods in food safety, such as long detection time, low sensitivity, difficult, and expensive antibody preparation. This review provides an overview of various aptamer screening technologies and summarizes the recent applications of aptamers in food safety, and future prospects are also discussed.
Collapse
|
31
|
Dong Y, Xu Y, Yong W, Chu X, Wang D. Aptamer and its potential applications for food safety. Crit Rev Food Sci Nutr 2014; 54:1548-61. [PMID: 24580557 DOI: 10.1080/10408398.2011.642905] [Citation(s) in RCA: 71] [Impact Index Per Article: 6.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/18/2022]
Abstract
Accompanied by industrial globalization, rapid urbanization, and population increment, mass production and staple trading for food consumption are upsoaring continuously, foodborne disease resulted from various food safety issues is currently a crucial public health concern worldwide, which has not only created a great burden on both economy and society, but also greatly threatened the sustainability of mankind's livelihood and human reproduction. In order to better ensure food safety and thus effectively curb the occurrence of foodborne diseases, the development and evolving of inspection strategies are indispensable measures for quality assurance and conformity assessment. Nowadays, as complementary measures to and with advantageous merits over classic analytical methods, highly specific and selective aptamer-based assays have found their increasingly important roles in various domains of food analysis. This critical review summarizes the advantages of aptamer as compared with antibody, introduces important evolving variants of systematic evolution of ligands by exponential enrichment (SELEX), and presents an overview of potential aptamer applications for food safety.
Collapse
Affiliation(s)
- Yiyang Dong
- a Beijing Key Laboratory of Bioprocess, College of Life Science and Technology , Beijing University of Chemical Technology , Beijing , P.R. China
| | | | | | | | | |
Collapse
|
32
|
A direct competitive assay-based aptasensor for sensitive determination of tetracycline residue in honey. Talanta 2014; 131:562-9. [PMID: 25281141 DOI: 10.1016/j.talanta.2014.08.028] [Citation(s) in RCA: 72] [Impact Index Per Article: 6.5] [Reference Citation Analysis] [Abstract] [Key Words] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/25/2014] [Revised: 08/07/2014] [Accepted: 08/09/2014] [Indexed: 02/07/2023]
Abstract
Tetracycline (TC) is a common antibacterial agent used for prevention and control of animal diseases. The increasing concern about TC residue in food demands high-performing analytical techniques for food quality assessment. Biosensors represent a promising tool for food safety analysis as they can fulfill some demand that the conventional methods do not attain. In this study, a novel colorimetric aptasensor was developed for sensitive detection of TC in honey. The aptasensor was based on a modified direct competitive enzyme-linked aptamer assay (dc-ELAA) scheme utilizing a 76 mer single-stranded DNA (ssDNA) aptamer selected by Systematic Evolution of Ligands by Exponential Enrichment (SELEX). The optimized aptasensor showed a good limit of detection (LOD of 0.0978 ng/mL), a wide linear range (0.1-1000 ng/mL) toward TC in honey, with good recoveries (92.09-109.7%) in TC-spiked honey, and was compared with an indirect competitive assay-based aptasensor and validated with a standard ELISA. The biosensor based on dc-ELAA with good limit of detection and simplicity can be applied for high-throughput detection of TC in food.
Collapse
|
33
|
Hayat A, Marty JL. Aptamer based electrochemical sensors for emerging environmental pollutants. Front Chem 2014; 2:41. [PMID: 25019067 PMCID: PMC4071757 DOI: 10.3389/fchem.2014.00041] [Citation(s) in RCA: 88] [Impact Index Per Article: 8.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/16/2014] [Accepted: 06/09/2014] [Indexed: 12/30/2022] Open
Abstract
Environmental contaminants monitoring is one of the key issues in understanding and managing hazards to human health and ecosystems. In this context, aptamer based electrochemical sensors have achieved intense significance because of their capability to resolve a potentially large number of problems and challenges in environmental contamination. An aptasensor is a compact analytical device incorporating an aptamer (oligonulceotide) as the sensing element either integrated within or intimately associated with a physiochemical transducer surface. Nucleic acid is well known for the function of carrying and passing genetic information, however, it has found a key role in analytical monitoring during recent years. Aptamer based sensors represent a novelty in environmental analytical science and there are great expectations for their promising performance as alternative to conventional analytical tools. This review paper focuses on the recent advances in the development of aptamer based electrochemical sensors for environmental applications with special emphasis on emerging pollutants.
Collapse
Affiliation(s)
- Akhtar Hayat
- BIOMEM, Université de Perpignan Perpignan, France ; Interdisciplinary Research Centre in Biomedical Materials, COMSATS Institute of Information Technology Lahore, Pakistan
| | - Jean L Marty
- BIOMEM, Université de Perpignan Perpignan, France
| |
Collapse
|
34
|
Wang S, Yong W, Liu J, Zhang L, Chen Q, Dong Y. Development of an indirect competitive assay-based aptasensor for highly sensitive detection of tetracycline residue in honey. Biosens Bioelectron 2014; 57:192-8. [PMID: 24583691 DOI: 10.1016/j.bios.2014.02.032] [Citation(s) in RCA: 90] [Impact Index Per Article: 8.2] [Reference Citation Analysis] [Abstract] [Key Words] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/30/2013] [Revised: 02/08/2014] [Accepted: 02/11/2014] [Indexed: 10/25/2022]
Abstract
Tetracycline (TC) is widely used for prevention and control of animal diseases for its broad spectrum antimicrobial activity and low cost, but its abuse can seriously affect human health and may result in trade loss. Thus there is an imperative need to develop high-performing analytical technique for TC detection. In this study, we developed a biosensor based on an indirect competitive enzyme-linked aptamer assay (ic-ELAA). A 76mer single-stranded DNA (ssDNA) aptamer, selected by Systematic Evolution of Ligands by Exponential Enrichment (SELEX), was applied for the recognition and detection of TC in honey. The limit of detection was 9.6×10(-3) ng/mL with a linear working range from 0.01 to 100 ng/mL toward TC in honey, and a mean recovery rate of 93.23% in TC-spiked honey was obtained. This aptasensor can be applied to detect TC residue in food with high sensitivity and simplicity, and it is prospective to develop useful ELAA Kits for TC determination in food.
Collapse
Affiliation(s)
- Sai Wang
- Beijing Key Laboratory of Bioprocess, College of Life Science and Technology, Beijing University of Chemical Technology, Beijing 100029, PR China
| | - Wei Yong
- Institute of Food Safety, Chinese Academy of Inspection and Quarantine, Beijing 100123, PR China
| | - Jiahui Liu
- Beijing Key Laboratory of Bioprocess, College of Life Science and Technology, Beijing University of Chemical Technology, Beijing 100029, PR China
| | - Liya Zhang
- Beijing Key Laboratory of Bioprocess, College of Life Science and Technology, Beijing University of Chemical Technology, Beijing 100029, PR China
| | - Qilong Chen
- Beijing Key Laboratory of Bioprocess, College of Life Science and Technology, Beijing University of Chemical Technology, Beijing 100029, PR China
| | - Yiyang Dong
- Beijing Key Laboratory of Bioprocess, College of Life Science and Technology, Beijing University of Chemical Technology, Beijing 100029, PR China.
| |
Collapse
|
35
|
Wu J, Zhu Y, Xue F, Mei Z, Yao L, Wang X, Zheng L, Liu J, Liu G, Peng C, Chen W. Recent trends in SELEX technique and its application to food safety monitoring. Mikrochim Acta 2014; 181:479-491. [PMID: 25419005 DOI: 10.1007/s00604-013-1156-7] [Citation(s) in RCA: 74] [Impact Index Per Article: 6.7] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/26/2023]
Abstract
The method referred to as "systemic evolution of ligands by exponential enrichment" (SELEX) was introduced in 1990 and ever since has become an important tool for the identification and screening of aptamers. Such nucleic acids can recognize and bind to their corresponding targets (analytes) with high selectivity and affinity, and aptamers therefore have become attractive alternatives to traditional antibodies not the least because they are much more stable. Meanwhile, they have found numerous applications in different fields including food quality and safety monitoring. This review first gives an introduction into the selection process and to the evolution of SELEX, then covers applications of aptamers in the surveillance of food safety (with subsections on absorptiometric, electrochemical, fluorescent and other methods), and then gives conclusions and perspectives. The SELEX method excels by its features of in vitro, high throughput and ease of operation. This review contains 86 references.
Collapse
Affiliation(s)
- Jingjing Wu
- School of Biotechnology and Food Engineering, Anhui Provincial Key Lab of Functional Materials & Devices, Hefei University of Technology, Hefei 230009, People's Republic of China
| | - Yingyue Zhu
- School of Biotechnology and Food Engineering, Changshu Institute of Technology, Changshu 215500, People's Republic of China
| | - Feng Xue
- School of Biotechnology and Food Engineering, Anhui Provincial Key Lab of Functional Materials & Devices, Hefei University of Technology, Hefei 230009, People's Republic of China
| | - Zhanlong Mei
- School of Biotechnology and Food Engineering, Anhui Provincial Key Lab of Functional Materials & Devices, Hefei University of Technology, Hefei 230009, People's Republic of China
| | - Li Yao
- School of Biotechnology and Food Engineering, Anhui Provincial Key Lab of Functional Materials & Devices, Hefei University of Technology, Hefei 230009, People's Republic of China
| | - Xin Wang
- School of Biotechnology and Food Engineering, Anhui Provincial Key Lab of Functional Materials & Devices, Hefei University of Technology, Hefei 230009, People's Republic of China
| | - Lei Zheng
- School of Medical Engineering, Hefei University of Technology, Hefei 230009, People's Republic of China
| | - Jian Liu
- School of Biotechnology and Food Engineering, Anhui Provincial Key Lab of Functional Materials & Devices, Hefei University of Technology, Hefei 230009, People's Republic of China
| | - Guodong Liu
- Department of Chemistry and Biochemistry, North Dakota State University, Fargo, ND 58108, USA
| | - Chifang Peng
- School Food Science & Technology, Jiangnan University, Wuxi 214122, People's Republic of China
| | - Wei Chen
- School of Biotechnology and Food Engineering, Anhui Provincial Key Lab of Functional Materials & Devices, Hefei University of Technology, Hefei 230009, People's Republic of China
| |
Collapse
|
36
|
Jiang S, Xu J, Xu P, Liu L, Chen Y, Qiao C, Yang S, Sha Z, Zhang J. A Novel Molecularly Imprinted Sensor for Direct Tartrazine Detection. ANAL LETT 2013. [DOI: 10.1080/00032719.2013.834442] [Citation(s) in RCA: 17] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/26/2022]
|
37
|
Kim CH, Lee LP, Min JR, Lim MW, Jeong SH. An indirect competitive assay-based aptasensor for detection of oxytetracycline in milk. Biosens Bioelectron 2013; 51:426-30. [PMID: 24011458 DOI: 10.1016/j.bios.2013.08.003] [Citation(s) in RCA: 92] [Impact Index Per Article: 7.7] [Reference Citation Analysis] [Abstract] [Key Words] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/28/2013] [Revised: 08/03/2013] [Accepted: 08/05/2013] [Indexed: 02/06/2023]
Abstract
Oxytetracycline (OTC) is a common antibacterial agent used for the control of animal diseases. OTC abuse can seriously affect human health; therefore, we developed a biosensor using single-stranded DNA (ssDNA) aptamers for the detection of OTC. The binding probe aptamers for OTC were selected by a Systematic Evolution of Ligands by the exponential enrichment (SELEX) process and identified by the enzyme-linked aptamer assay (ELAA). Among the selected 5 aptamers, aptamer OTC3 showed the strongest affinity (Kd=4.7 nM) and highest specificity for OTC compared to structurally similar antibiotics, tetracycline and chlortetracycline. OTC was detected using indirect competitive ELAA. The limit of detection and quantitation with aptamer OTC3 were 12.3 and 49.8 µg/L, respectively, in milk and showed recovery rates of more than 90% in OTC-spiked milk. This biosensor method with high sensitivity and specificity based on indirect competitive ELAA can be applied to OTC detection in food products on-site because of the simplicity of detection.
Collapse
Affiliation(s)
- Chong-Han Kim
- Department of Bio Applied Toxicology, Hoseo Toxicology Research Center, Hoseo University, Asan 336-795, South Korea
| | | | | | | | | |
Collapse
|
38
|
He L, Luo Y, Zhi W, Wu Y, Zhou P. A Colorimetric Aptamer Biosensor Based on Gold Nanoparticles for the Ultrasensitive and Specific Detection of Tetracycline in Milk. Aust J Chem 2013. [DOI: 10.1071/ch12446] [Citation(s) in RCA: 21] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/28/2023]
Abstract
This paper proposes a sensing strategy which employs an aptamer, unmodified gold nanoparticles (AuNP), and hexadecyltrimethylammonium bromide (CTAB) to detect tetracycline (TET) in raw milk. The method is based on the colorimetric assay of aggregating AuNP. In the absence of TET, the CTAB and aptamer form a complex which allows the aggregation of AuNP. In the presence of TET, the TET aptamer is exhausted first due to the formation of aptamer-TET complexes, which prevents assembly of the CTAB–aptamer supramolecule, causing a colour change and no aggregation of AuNP. This mechanism for the detection of TET proved to be sensitive and convenient. The colorimetric assay has a detection limit of 122 nM TET. This sensor has great potential for the sensitive, colorimetric detection of a wide range of molecular analytes.
Collapse
|
39
|
Chen A, Jiang X, Zhang W, Chen G, Zhao Y, Tunio TM, Liu J, Lv Z, Li C, Yang S. High sensitive rapid visual detection of sulfadimethoxine by label-free aptasensor. Biosens Bioelectron 2012; 42:419-25. [PMID: 23228493 DOI: 10.1016/j.bios.2012.10.059] [Citation(s) in RCA: 64] [Impact Index Per Article: 4.9] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/07/2012] [Revised: 09/29/2012] [Accepted: 10/17/2012] [Indexed: 02/01/2023]
Abstract
Quickly and sensitively detection of antibiotic residues in animal products often requires time-consuming techniques and expensive instrumentation. To address these limitations, a high sensitive aptasensor for sulfadimethoxine (SDM) using unmodified gold nanoparticles (AuNPs) was developed in the present study. The assay sensitivity was improved by optimizing several key parameters such as the amount of aptamer adsorbed to AuNPs, the concentration of salt and the AuNPs pH value. To our knowledge, this is the first time to investigate the effect of AuNPs pH value on the sensitivity of aptamer-AuNPs based label-free assay. The best procedure for SDM analysis in our system was: the pH value at 8.0, and the concentration of aptamer at 2 μM, and the concentration of salt at 2 M. The linear range for the current analytical system was from 50 ng/mL to 1 μg/mL, and the detection limit was 50 ng/mL, which is lower than the Maximum Residue Limit (MRL) (100 ng/mL) in edible animal tissues regulated by China and European commission. Our study provides a simple, fast, and easy to read method for SDM analysis with high sensitivity, which can be applied in future on-site detection in animal products.
Collapse
Affiliation(s)
- Ailiang Chen
- Institute of Quality Standards and Testing Technology for Agro-products, Key Laboratory of Agro-product Quality and Safety, Chinese Academy of Agricultural Sciences, Beijing 100081, China
| | | | | | | | | | | | | | | | | | | |
Collapse
|
40
|
Zhang J, Wu Y, Zhang B, Li M, Jia S, Jiang S, Zhou H, Zhang Y, Zhang C, Turner APF. Label-Free Electrochemical Detection of Tetracycline by an Aptamer Nano-Biosensor. ANAL LETT 2012. [DOI: 10.1080/00032719.2012.670784] [Citation(s) in RCA: 25] [Impact Index Per Article: 1.9] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/28/2022]
|
41
|
Sett A, Das S, Sharma P, Bora U. Aptasensors in Health, Environment and Food Safety Monitoring. ACTA ACUST UNITED AC 2012. [DOI: 10.4236/ojab.2012.12002] [Citation(s) in RCA: 27] [Impact Index Per Article: 2.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/20/2022]
|
42
|
Biosensor applications in the field of antibiotic research--a review of recent developments. SENSORS 2011; 11:9450-66. [PMID: 22163705 PMCID: PMC3231281 DOI: 10.3390/s111009450] [Citation(s) in RCA: 49] [Impact Index Per Article: 3.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 08/05/2011] [Revised: 09/09/2011] [Accepted: 09/21/2011] [Indexed: 01/18/2023]
Abstract
Antibacterials are among of the most important medications used in health care. However, their efficacy is increasingly impeded by a tremendous and globally spread bacterial resistance phenomenon. This bacterial resistance is accelerated by inadequate application of antibacterial drugs in humans, the widespread veterinary use of antibacterials, and antibacterial occurrence in the environment and food. Further, there is a lack of development of innovative novel drugs. Therefore, the search for novel antibacterials has to be intensified and the spread of antibacterials in the environment has to be restricted. Due to the fundamental progress in biosensor development and promising applications in the antibiotic field, this review gives for the first time an overview on the use and prospects of biosensor applications in that area. A number of reports have applied biosensors of different design and techniques to search for antibacterials in environmental and foodstuff matrices. These studies are discussed with respect to the analytical values and compared to conventional techniques. Furthermore, biosensor applications to elucidate the mode of action of antimicrobial drugs in vitro have been described. These studies were critically introduced referring to the informational value of those simulations. In summary, biosensors will be illustrated as an innovative and promising, although not yet comprehensively applied, technique in the antibacterial field.
Collapse
|
43
|
Affiliation(s)
- Anton B. Iliuk
- Department of Biochemistry and Purdue Center for Cancer Research, Purdue University, West Lafayette, IN 47907
| | - Lianghai Hu
- Department of Biochemistry and Purdue Center for Cancer Research, Purdue University, West Lafayette, IN 47907
| | - W. Andy Tao
- Department of Biochemistry and Purdue Center for Cancer Research, Purdue University, West Lafayette, IN 47907
| |
Collapse
|