1
|
Ren J, Li Q, Feng K, Gong J, Li Z, Liu X, Yang L, Zhang J. A wearable sensor based on janus fabric upon an electrochemical analysis platform for sweat glucose detection. Talanta 2025; 284:127236. [PMID: 39581105 DOI: 10.1016/j.talanta.2024.127236] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/28/2024] [Revised: 09/09/2024] [Accepted: 11/17/2024] [Indexed: 11/26/2024]
Abstract
Wearable sweat sensing devices have drawn much attention due to their noninvasive and portable properties, which is emerging as a promising technology in daily healthiness assessment issues. A sweat sensor based on Janus fabric and electrochemical analysis is proposed in this work. Unidirectional moisture transported behavior of the Janus fabric serves as the quick-drying component directly contacting skin to transfer sweat toward the detection site. The working electrode was treated by repeated activation of Prussian blue followed by chitosan/single-wall carbon nano tubes/glucose oxidase deposition, ensuring the high electrochemical activity and sensitivity to detect the sweat glucose level. A detection system was established based on the electrochemical analysis of this sweat sensor, which can provide accurate glucose level in the testing samples. The limit of detection (LOD) of the sensor for glucose was 15.32 μM (S/N = 3) and the sensitivity was 3.35 μA/mM. One male subject wears this sensor for intermittent intensity training, outputting the real-time changes in sweat glucose levels, which is consistent with the energy consumption and metabolic status during human exercise. And the sweat glucose level for different subjects was tested to be 35-135 μM, which is coincident with the distribution range of normal human sweat glucose levels.
Collapse
Affiliation(s)
- Jianing Ren
- School of Textile Science and Engineering, Tiangong University, Tianjin 300387, China; Key Laboratory of Advanced Textile Composites, Ministry of Education, Tiangong University, Tianjin 300387, China
| | - Qiujin Li
- School of Textile Science and Engineering, Tiangong University, Tianjin 300387, China; Key Laboratory of Advanced Textile Composites, Ministry of Education, Tiangong University, Tianjin 300387, China; National Innovation Center of Advanced Dyeing & Finishing Technology, Tai'an, Shandong 271000, China.
| | - Kexin Feng
- School of Textile Science and Engineering, Tiangong University, Tianjin 300387, China; Key Laboratory of Advanced Textile Composites, Ministry of Education, Tiangong University, Tianjin 300387, China
| | - Jixian Gong
- School of Textile Science and Engineering, Tiangong University, Tianjin 300387, China; Key Laboratory of Advanced Textile Composites, Ministry of Education, Tiangong University, Tianjin 300387, China
| | - Zheng Li
- School of Textile Science and Engineering, Tiangong University, Tianjin 300387, China; Key Laboratory of Advanced Textile Composites, Ministry of Education, Tiangong University, Tianjin 300387, China
| | - Xiuming Liu
- School of Textile Science and Engineering, Tiangong University, Tianjin 300387, China; Key Laboratory of Advanced Textile Composites, Ministry of Education, Tiangong University, Tianjin 300387, China
| | - Li Yang
- School of Textile Science and Engineering, Tiangong University, Tianjin 300387, China; Key Laboratory of Advanced Textile Composites, Ministry of Education, Tiangong University, Tianjin 300387, China.
| | - Jianfei Zhang
- School of Textile Science and Engineering, Tiangong University, Tianjin 300387, China; Key Laboratory of Advanced Textile Composites, Ministry of Education, Tiangong University, Tianjin 300387, China; National Innovation Center of Advanced Dyeing & Finishing Technology, Tai'an, Shandong 271000, China; Collaborative Innovation Center for Eco-Textiles of Shandong Province, Shandong, Qingdao 266071, China
| |
Collapse
|
2
|
Järvinen T, Pitkänen O, Laurila T, Mannerkorpi M, Saarakkala S, Kordas K. A customizable wireless potentiostat for assessing Ni(OH) 2 decorated vertically aligned MoS 2 thin films for electrochemical sensing of dopamine. NANOSCALE ADVANCES 2025; 7:1374-1383. [PMID: 39845132 PMCID: PMC11747886 DOI: 10.1039/d4na00914b] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 11/05/2024] [Accepted: 12/30/2024] [Indexed: 01/24/2025]
Abstract
In this study, we show that on-chip grown, vertically aligned MoS2 films that are decorated with Ni(OH)2 catalyst are suitable materials to be applied as working electrodes in electrochemical sensing. The constructed sensors display a highly repeatable response to dopamine, used as a model analyte, in a large dynamic range from 1 μM to 1 mM with a theoretical detection limit of 0.1 μM. In addition, to facilitate practical implementation of the sensor chips, we also demonstrate a low power wireless cyber-physical system that we designed and accommodated for cyclic voltammetry measurements. The developed cost-effective and portable instrument enables straightforward data acquisition, transfer and visualization through an Android mobile interface, and has an accuracy comparable to reference analysis of our sensors using a commercial table-top laboratory potentiostat.
Collapse
Affiliation(s)
- Topias Järvinen
- Microelectronics Research Unit, Faculty of Information Technology and Electrical Engineering, University of Oulu PO Box 4500 90014 Finland
| | - Olli Pitkänen
- Microelectronics Research Unit, Faculty of Information Technology and Electrical Engineering, University of Oulu PO Box 4500 90014 Finland
| | - Tomi Laurila
- Department of Electrical Engineering and Automation, School of Electrical Engineering, Aalto University PO Box 13500, 00076 Aalto Finland
| | - Minna Mannerkorpi
- Research Unit of Health Sciences and Technology, Faculty of Medicine, University of Oulu PO Box 5000 90014 Finland
| | - Simo Saarakkala
- Research Unit of Health Sciences and Technology, Faculty of Medicine, University of Oulu PO Box 5000 90014 Finland
| | - Krisztian Kordas
- Microelectronics Research Unit, Faculty of Information Technology and Electrical Engineering, University of Oulu PO Box 4500 90014 Finland
| |
Collapse
|
3
|
Choudhury S, Zafar S, Deepak D, Panghal A, Lochab B, Roy SS. A surface modified laser-induced graphene based flexible biosensor for multiplexed sweat analysis. J Mater Chem B 2024; 13:274-287. [PMID: 39535206 DOI: 10.1039/d4tb01936a] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/16/2024]
Abstract
The growing popularity of electrochemical sensors featuring non-invasive biosensing technologies has generated significant enthusiasm for continuous monitoring of bodily fluid biomarkers, potentially aiding in the early detection of health issues in individuals. However, detection of multiple biomarkers in complex biofluids often necessitates a high-density array which creates a challenge in achieving cost-effective fabrication methods. To overcome this constraint, this work reports the fabrication of an electrochemical sensor utilizing a NiO-Ti3C2Tx MXene-modified flexible laser-induced graphene (LIG) electrode for the separate and concurrent analysis of ascorbic acid (AA), dopamine (DA), and uric acid (UA) in human sweat and also addresses the deficiencies in the existing state of the art by offering a cost-efficient and high-performance sensor that mitigates the degrading constraints of conventional LIG electrodes. Cyclic voltammetry and differential pulse voltammetry measurements reveals that the electrochemical properties of the modified electrode, attain a low detection limit and great sensitivity for the target biomarkers. The NiO-Ti3C2Tx/LIG sensor demonstrated enhanced electrocatalytic activity for the oxidation of ascorbic acid, dopamine, and uric acid, and proved useful for analysing these biomarkers in synthetic sweat samples. Under the optimized conditions, the LOD values were estimated to be 16, 1.97 and 0.78 μM for AA, DA and UA, respectively. The developed high-efficiency sensor holds significant promise for applications in flexible and wearable electronics for health monitoring.
Collapse
Affiliation(s)
- Sudipta Choudhury
- Department of Physics, School of Natural Sciences, Shiv Nadar Institution of Eminence (SNIoE), Deemed to be University, Delhi-NCR, Greater Noida, 201314, India.
| | - Saad Zafar
- Materials Chemistry Laboratory, Department of Chemistry, School of Natural Sciences, Shiv Nadar Institution of Eminence, Delhi-NCR, Greater Noida, 201314, India
| | - Deepak Deepak
- Department of Physics, School of Natural Sciences, Shiv Nadar Institution of Eminence (SNIoE), Deemed to be University, Delhi-NCR, Greater Noida, 201314, India.
| | - Abhishek Panghal
- Department of Physics, School of Natural Sciences, Shiv Nadar Institution of Eminence (SNIoE), Deemed to be University, Delhi-NCR, Greater Noida, 201314, India.
| | - Bimlesh Lochab
- Materials Chemistry Laboratory, Department of Chemistry, School of Natural Sciences, Shiv Nadar Institution of Eminence, Delhi-NCR, Greater Noida, 201314, India
| | - Susanta Sinha Roy
- Department of Physics, School of Natural Sciences, Shiv Nadar Institution of Eminence (SNIoE), Deemed to be University, Delhi-NCR, Greater Noida, 201314, India.
| |
Collapse
|
4
|
Tang S, He B, Liu Y, Wang L, Liang Y, Wang J, Jin H, Wei M, Ren W, Suo Z, Xu Y. A dual-signal mode electrochemical aptasensor based on tetrahedral DNA nanostructures for sensitive detection of citrinin in food using PtPdCo mesoporous nanozymes. Food Chem 2024; 460:140739. [PMID: 39116770 DOI: 10.1016/j.foodchem.2024.140739] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/20/2024] [Revised: 07/17/2024] [Accepted: 07/31/2024] [Indexed: 08/10/2024]
Abstract
Citrinin (CIT) is a mycotoxin with nephrotoxicity and hepatotoxicity, presenting a significant threat to human health that is often overlooked. Therefore, a dual-signal mode (DPV and SWV) aptasensor for citrinin (CIT) detection was constructed based on tetrahedral DNA nanostructures (TDN) in this study. Furthermore, PtPdCo mesoporous nanozymes exhibit catalase-like catalytic functions, generating significant electrochemical signals through a Fenton-like reaction. Meanwhile their excellent Methylene Blue (MB) loading capability ensures independent dual signal outputs. The RecJf exonuclease-assisted (RecJf Exo-assisted) process can expand the linear detection range, enabling further amplification of the signal. Under optimized conditions, the constructed aptaensor exhibited excellent detection performance with limits of detection (LODs) of 7.67 × 10-3 ng·mL-1 (DPV mode) and 1.57 × 10-3 ng·mL-1 (SWV mode). Due to its multiple signal amplification and highly accurate dual-signal mode detection capability, this aptasensor shows promising potential for the in situ detection.
Collapse
Affiliation(s)
- Shi Tang
- School of Food Science and Technology, Henan University of Technology, Zhengzhou, Henan 450001, PR China
| | - Baoshan He
- School of Food Science and Technology, Henan University of Technology, Zhengzhou, Henan 450001, PR China.
| | - Yao Liu
- Henan Scientific Research Platform Service Center, Zhengzhou, Henan 450003, PR China
| | - Longdi Wang
- COFCO Lijin (Tianjin) Grain and Oil Co., Ltd., Tianjin, 300112, PR China
| | - Ying Liang
- College of Biological Engineering, Henan University of Technology, Zhengzhou, Henan 450001, PR China
| | - Jinshui Wang
- College of Biological Engineering, Henan University of Technology, Zhengzhou, Henan 450001, PR China.
| | - Huali Jin
- School of Food Science and Technology, Henan University of Technology, Zhengzhou, Henan 450001, PR China
| | - Min Wei
- School of Food Science and Technology, Henan University of Technology, Zhengzhou, Henan 450001, PR China
| | - Wenjie Ren
- School of Food Science and Technology, Henan University of Technology, Zhengzhou, Henan 450001, PR China
| | - Zhiguang Suo
- School of Food Science and Technology, Henan University of Technology, Zhengzhou, Henan 450001, PR China
| | - Yiwei Xu
- School of Food Science and Technology, Henan University of Technology, Zhengzhou, Henan 450001, PR China
| |
Collapse
|
5
|
Sudewi S, Li CH, Penki VSS, Zulfajri M, Meitei NJ, Huang GG. Colorimetric and Smartphone-Based Dual-Mode Rapid Detection of Congo Red Using Iron Oxide Quantum Dots. ACS OMEGA 2024; 9:46600-46609. [PMID: 39583682 PMCID: PMC11579718 DOI: 10.1021/acsomega.4c08644] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 09/20/2024] [Revised: 10/24/2024] [Accepted: 10/25/2024] [Indexed: 11/26/2024]
Abstract
Congo red is toxic to humans and the environment and persists in the environment for long periods. Therefore, developing a rapid detection method for Congo red is crucial. In this study, iron oxide quantum dots (IOQDs) were synthesized and employed for dual-mode detection (colorimetric and smartphone-based) of Congo red in real samples. Upon mixing with Congo red, the IOQDs induce a color change in the solution due to the strong intermolecular interactions between Congo red and the IOQDs, making them practical as colorimetric sensors. To further increase the on-site detection capabilities of IOQDs, images of the sensor platform were captured using a smartphone, and the color data were analyzed with a dedicated APP. As a colorimetric sensor, the ultraviolet-visible (UV-vis) absorbance response exhibited good linearity for Congo red concentrations between 2 and 50 μM, with a detection limit of 0.89 μM. The smartphone-based sensor also provided highly quantitative results, showing a linear relationship between Congo red concentrations and the blue-to-red (B/R) channel ratio, with a detection limit of 0.58 μM. Moreover, this dual-mode method demonstrated better selectivity for Congo red than other colorimetric sensors, even in the presence of other red dyes. The proposed method is convenient, fast, low-cost, and suitable for real-sample applications.
Collapse
Affiliation(s)
- Sri Sudewi
- Department
of Pharmacy, Faculty of Mathematics and Natural Science, Universitas Sam Ratulangi, Manado 95115, Indonesia
| | - Chien-Hung Li
- Department
of Medicinal and Applied Chemistry, Kaohsiung
Medical University, Kaohsiung 80708, Taiwan
| | | | - Muhammad Zulfajri
- Department
of Chemistry Education, Universitas Serambi
Mekkah, Banda Aceh, Aceh 23245, Indonesia
| | - Naorem Jemes Meitei
- Department
of Medicinal and Applied Chemistry, Kaohsiung
Medical University, Kaohsiung 80708, Taiwan
| | - Genin Gary Huang
- Department
of Medicinal and Applied Chemistry, Kaohsiung
Medical University, Kaohsiung 80708, Taiwan
- Department
of Medical Research, Kaohsiung Medical University
Hospital, Kaohsiung 80708, Taiwan
- Department
of Chemistry, National Sun Yat-Sen University, Kaohsiung 80424, Taiwan
| |
Collapse
|
6
|
Bezinge L, Shih CJ, Richards DA, deMello AJ. Electrochemical Paper-Based Microfluidics: Harnessing Capillary Flow for Advanced Diagnostics. SMALL (WEINHEIM AN DER BERGSTRASSE, GERMANY) 2024; 20:e2401148. [PMID: 38801400 DOI: 10.1002/smll.202401148] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 02/13/2024] [Revised: 04/29/2024] [Indexed: 05/29/2024]
Abstract
Electrochemical paper-based microfluidics has attracted much attention due to the promise of transforming point-of-care diagnostics by facilitating quantitative analysis with low-cost and portable analyzers. Such devices harness capillary flow to transport samples and reagents, enabling bioassays to be executed passively. Despite exciting demonstrations of capillary-driven electrochemical tests, conventional methods for fabricating electrodes on paper impede capillary flow, limit fluidic pathways, and constrain accessible device architectures. This account reviews recent developments in paper-based electroanalytical devices and offers perspective by revisiting key milestones in lateral flow tests and paper-based microfluidics engineering. The study highlights the benefits associated with electrochemical sensing and discusses how the detection modality can be leveraged to unlock novel functionalities. Particular focus is given to electrofluidic platforms that embed electrodes into paper for enhanced biosensing applications. Together, these innovations pave the way for diagnostic technologies that offer portability, quantitative analysis, and seamless integration with digital healthcare, all without compromising the simplicity of commercially available rapid diagnostic tests.
Collapse
Affiliation(s)
- Léonard Bezinge
- Department of Chemistry and Applied Biosciences, Institute for Chemical and Bioengineering, ETH Zürich, Vladimir-Prelog-Weg 1, Zürich, 8093, Switzerland
| | - Chih-Jen Shih
- Department of Chemistry and Applied Biosciences, Institute for Chemical and Bioengineering, ETH Zürich, Vladimir-Prelog-Weg 1, Zürich, 8093, Switzerland
| | - Daniel A Richards
- Department of Chemistry and Applied Biosciences, Institute for Chemical and Bioengineering, ETH Zürich, Vladimir-Prelog-Weg 1, Zürich, 8093, Switzerland
| | - Andrew J deMello
- Department of Chemistry and Applied Biosciences, Institute for Chemical and Bioengineering, ETH Zürich, Vladimir-Prelog-Weg 1, Zürich, 8093, Switzerland
| |
Collapse
|
7
|
Upadhyay S, Kumar A, Srivastava M, Srivastava A, Dwivedi A, Singh RK, Srivastava SK. Recent advancements of smartphone-based sensing technology for diagnosis, food safety analysis, and environmental monitoring. Talanta 2024; 275:126080. [PMID: 38615454 DOI: 10.1016/j.talanta.2024.126080] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/29/2024] [Revised: 04/04/2024] [Accepted: 04/07/2024] [Indexed: 04/16/2024]
Abstract
The emergence of computationally powerful smartphones, relatively affordable high-resolution camera, drones, and robotic sensors have ushered in a new age of advanced sensible monitoring tools. The present review article investigates the burgeoning smartphone-based sensing paradigms, including surface plasmon resonance (SPR) biosensors, electrochemical biosensors, colorimetric biosensors, and other innovations for modern healthcare. Despite the significant advancements, there are still scarcity of commercially available smart biosensors and hence need to accelerate the rates of technology transfer, application, and user acceptability. The application/necessity of smartphone-based biosensors for Point of Care (POC) testing, such as prognosis, self-diagnosis, monitoring, and treatment selection, have brought remarkable innovations which eventually eliminate sample transportation, sample processing time, and result in rapid findings. Additionally, it articulates recent advances in various smartphone-based multiplexed bio sensors as affordable and portable sensing platforms for point-of-care devices, together with statistics for point-of-care health monitoring and their prospective commercial viability.
Collapse
Affiliation(s)
- Satyam Upadhyay
- Department of Physics, Institute of Science, Banaras Hindu University, Varanasi, 221005, India
| | - Anil Kumar
- Department of Physics, Institute of Science, Banaras Hindu University, Varanasi, 221005, India
| | - Monika Srivastava
- School of Materials Science and Technology, Indian Institute of Technology (Banaras Hindu University), Varanasi, India
| | - Amit Srivastava
- Department of Physics TDPG College, VBS Purvanchal University, Jaunpur, 222001, India
| | - Arpita Dwivedi
- Department of Physics, Institute of Science, Banaras Hindu University, Varanasi, 221005, India
| | - Rajesh Kumar Singh
- School of Physical and Material Sciences, Central University of Himachal Pradesh, Dharamshala, Kangra, 176215, India
| | - S K Srivastava
- Department of Physics, Institute of Science, Banaras Hindu University, Varanasi, 221005, India.
| |
Collapse
|
8
|
Bezinge L, deMello AJ, Shih CJ, Richards DA. Quantitative reagent monitoring in paper-based electrochemical rapid diagnostic tests. LAB ON A CHIP 2024; 24:3651-3657. [PMID: 38952211 DOI: 10.1039/d4lc00390j] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 07/03/2024]
Abstract
Paper-based rapid diagnostic tests (RDTs) are an essential component of modern healthcare, particularly for the management of infectious diseases. Despite their utility, these capillary-driven RDTs are compromised by high failure rates, primarily caused by user error. This limits their utility in complex assays that require multiple user operations. Here, we demonstrate how this issue can be directly addressed through continuous electrochemical monitoring of reagent flow inside an RDT using embedded graphenized electrodes. Our method relies on applying short voltage pulses and measuring variations in capacitive discharge currents to precisely determine the flow times of injected samples and reagents. This information is reported to the user, guiding them through the testing process, highlighting failure cases and ultimately decreasing errors. Significantly, the same electrodes can be used to quantify electrochemical signals from immunoassays, providing an integrated solution for both monitoring assays and reporting results. We demonstrate the applicability of this approach in a serology test for the detection of anti-SARS-CoV-2 IgG in clinical serum samples. This method paves the way towards "smart" RDTs able to continuously monitor the testing process and improve the robustness of point-of-care diagnostics.
Collapse
Affiliation(s)
- Léonard Bezinge
- Institute for Chemical and Bioengineering, Department of Chemistry and Applied Biosciences, ETH Zürich, Vladimir-Prelog-Weg 1, 8093 Zürich, Switzerland.
| | - Andrew J deMello
- Institute for Chemical and Bioengineering, Department of Chemistry and Applied Biosciences, ETH Zürich, Vladimir-Prelog-Weg 1, 8093 Zürich, Switzerland.
| | - Chih-Jen Shih
- Institute for Chemical and Bioengineering, Department of Chemistry and Applied Biosciences, ETH Zürich, Vladimir-Prelog-Weg 1, 8093 Zürich, Switzerland.
| | - Daniel A Richards
- Institute for Chemical and Bioengineering, Department of Chemistry and Applied Biosciences, ETH Zürich, Vladimir-Prelog-Weg 1, 8093 Zürich, Switzerland.
| |
Collapse
|
9
|
Dong Z, Zhu X, Tang J, Liao Y, Cheng X, Tang L, Fang L. An integrated smartphone-based electrochemical detection system for highly sensitive and on-site detection of chemical oxygen demand by copper-cobalt bimetallic oxide-modified electrode. Mikrochim Acta 2024; 191:343. [PMID: 38801537 DOI: 10.1007/s00604-024-06399-w] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/14/2024] [Accepted: 04/29/2024] [Indexed: 05/29/2024]
Abstract
A portable and integrated electrochemical detection system has been constructed for on-site and real-time detection of chemical oxygen demand (COD). The system mainly consists of four parts: (i) sensing electrode with a copper-cobalt bimetallic oxide (CuCoOx)-modified screen-printed electrode; (ii) an integrated electrochemical detector for the conversion, amplification, and transmission of weak signals; (iii) a smartphone installed with a self-developed Android application (APP) for issuing commands, receiving, and displaying detection results; and (iv) a 3D-printed microfluidic cell for the continuous input of water samples. Benefiting from the superior catalytic capability of CuCoOx, the developed system shows a high detection sensitivity with 0.335 μA/(mg/L) and a low detection limit of 5.957 mg/L for COD determination and possessing high anti-interference ability to chloride ions. Moreover, this system presents good consistency with the traditional dichromate method in COD detection of actual water samples. Due to the advantages of cost effectiveness, portability, and point-of-care testing, the system shows great potential for water quality monitoring, especially in resource-limited remote areas.
Collapse
Affiliation(s)
- Zhengrong Dong
- College of Electrical and Information Engineering, Hunan University, Changsha, 410012, China
- College of Environmental Science and Engineering, Key Laboratory of Environmental Biology and Pollution Control (Ministry of Education), Hunan University, Changsha, 410082, China
| | - Xu Zhu
- School of Environmental Science and Engineering, Tiangong University, Tianjin, 300387, China
| | - Jing Tang
- College of Environmental Science and Engineering, Key Laboratory of Environmental Biology and Pollution Control (Ministry of Education), Hunan University, Changsha, 410082, China
| | - Yibo Liao
- College of Environmental Science and Engineering, Key Laboratory of Environmental Biology and Pollution Control (Ministry of Education), Hunan University, Changsha, 410082, China
| | - Xingyang Cheng
- College of Environmental Science and Engineering, Key Laboratory of Environmental Biology and Pollution Control (Ministry of Education), Hunan University, Changsha, 410082, China
| | - Lin Tang
- College of Environmental Science and Engineering, Key Laboratory of Environmental Biology and Pollution Control (Ministry of Education), Hunan University, Changsha, 410082, China.
| | - Leyuan Fang
- College of Electrical and Information Engineering, Hunan University, Changsha, 410012, China.
| |
Collapse
|
10
|
Bezinge L, Tappauf N, Richards DA, Shih CJ, deMello AJ. Rapid Electrochemical Flow Analysis of Urinary Creatinine on Paper: Unleashing the Potential of Two-Electrode Detection. ACS Sens 2023; 8:3964-3972. [PMID: 37756250 PMCID: PMC10616850 DOI: 10.1021/acssensors.3c01640] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/09/2023] [Accepted: 09/08/2023] [Indexed: 09/29/2023]
Abstract
The development of low-cost, disposable electrochemical sensors is an essential step in moving traditionally inaccessible quantitative diagnostic assays toward the point of need. However, a major remaining limitation of current technologies is the reliance on standardized reference electrode materials. Integrating these reference electrodes considerably restricts the choice of the electrode substrate and drastically increases the fabrication costs. Herein, we demonstrate that adoption of two-electrode detection systems can circumvent these limitations and allow for the development of low-cost, paper-based devices. We showcase the power of this approach by developing a continuous flow assay for urinary creatinine enabled by an embedded graphenic two-electrode detector. The detection system not only simplifies sensor fabrication and readout hardware but also provides a robust sensing performance with high detection efficiencies. In addition to enabling high-throughput analysis of clinical urine samples, our two-electrode sensors provide unprecedented insights into the fundamental mechanism of the ferricyanide-mediated creatinine reaction. Finally, we developed a simplified circuitry to drive the detector. This forms the basis of a smart reader that guides the user through the measurement process. This study showcases the potential of affordable capillary-driven cartridges for clinical analysis within primary care settings.
Collapse
Affiliation(s)
- Léonard Bezinge
- Institute for Chemical and
Bioengineering, Department of Chemistry
and Applied Biosciences, ETH Zürich, Vladimir-Prelog-Weg 1, 8093 Zürich, Switzerland
| | - Niklas Tappauf
- Institute for Chemical and
Bioengineering, Department of Chemistry
and Applied Biosciences, ETH Zürich, Vladimir-Prelog-Weg 1, 8093 Zürich, Switzerland
| | - Daniel A. Richards
- Institute for Chemical and
Bioengineering, Department of Chemistry
and Applied Biosciences, ETH Zürich, Vladimir-Prelog-Weg 1, 8093 Zürich, Switzerland
| | - Chih-Jen Shih
- Institute for Chemical and
Bioengineering, Department of Chemistry
and Applied Biosciences, ETH Zürich, Vladimir-Prelog-Weg 1, 8093 Zürich, Switzerland
| | - Andrew J. deMello
- Institute for Chemical and
Bioengineering, Department of Chemistry
and Applied Biosciences, ETH Zürich, Vladimir-Prelog-Weg 1, 8093 Zürich, Switzerland
| |
Collapse
|
11
|
Wu C, Ge J, Gu F, Bai L. Electrochemical oxidation technique to pharmaceutical pollutants removal. CHEMOSPHERE 2023; 337:139373. [PMID: 37391083 DOI: 10.1016/j.chemosphere.2023.139373] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 05/24/2023] [Revised: 06/16/2023] [Accepted: 06/27/2023] [Indexed: 07/02/2023]
Abstract
Human progress in medical science and drug production has improved the growth process and increased human lifespan. Most of the drugs used are to control or prevent common human diseases. These drugs can be produced in different ways such as synthetic, chemical, biological, etc. On the other hand, pharmaceutical companies have a large volume of pharmaceutical effluents and wastewater that enters the environment and harms nature and human life. The main problems of entering the pharmaceutical effluent into the environmental cycle are the creation of drug resistance against the active substance of the drugs and the occurrence of abnormalities in the next generations. Therefore, the process of pharmaceutical wastewater treatment is used to reduce the level of pharmaceutical pollutants in order to enter the pharmaceutical wastewater into the environmental cycle. Until recently, filtration, passing through reverse osmosis and ion exchange resins, cleaning facilities, etc., have been various methods to remove pharmaceutical pollutants. Due to the low efficiency of the usual and old systems, the use of new methods has attracted more attention. In this article, the aim is to investigate the electrochemical oxidation method in order to remove the active ingredient of some commonly used drugs (aspirin, atorvastatin, metformin, metronidazole and ibuprofen) from the wastewater of pharmaceuticals. Therefore, in order to observe the initial conditions of the samples, a cyclic voltammetry diagram with a scanning rate of 100 mV/s has been performed. Next, by using the chronoamperometry process and applying a constant potential, the desired drugs were subjected to the electrochemical process of oxidation. As a result, the re-examined samples were subjected to cyclic voltammetry test to determine the conditions of sample oxidation peaks as well as the removal efficiency of the samples by examining the surface under the initial and final voltammetry graph. The results indicate that this method for removing selected drugs has a high removal efficiency of about 70% and 100% for atorvastatin samples. Therefore, this method is accurate, reproducible (RSD 2%), efficient, easy and economical and can be used in drug manufacturing industries. This method is used in a wide range of drug concentration. This means that by increasing the concentration of the drug, without the need to change the equipment used and the applied potential, by spending more time in the oxidation process, it is possible to remove very high amounts of the drug (more than 1000 ppm).
Collapse
Affiliation(s)
- Chunying Wu
- School of Resources and Environmental Engineering, Jilin Institute of Chemical Technology, Jilin, 32022, Jilin, China.
| | - Ji Ge
- School of Resources and Environmental Engineering, Jilin Institute of Chemical Technology, Jilin, 32022, Jilin, China.
| | - Feng Gu
- School of Resources and Environmental Engineering, Jilin Institute of Chemical Technology, Jilin, 32022, Jilin, China.
| | - Lu Bai
- School of Resources and Environmental Engineering, Jilin Institute of Chemical Technology, Jilin, 32022, Jilin, China.
| |
Collapse
|
12
|
Manoharan V, Rodrigues R, Sadati S, Swann MJ, Freeman N, Du B, Yildirim E, Tamer U, Arvanitis TN, Isakov D, Asadipour A, Charmet J. Platform-agnostic electrochemical sensing app and companion potentiostat. Analyst 2023; 148:4857-4868. [PMID: 37624366 PMCID: PMC10518900 DOI: 10.1039/d2an01350a] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/16/2022] [Accepted: 07/11/2023] [Indexed: 08/26/2023]
Abstract
Electrochemical sensing is ubiquitous in a number of fields ranging from biosensing, to environmental monitoring through to food safety and battery or corrosion characterisation. Whereas conventional potentiostats are ideal to develop assays in laboratory settings, they are in general, not well-suited for field work due to their size and power requirements. To address this need, a number of portable battery-operated potentiostats have been proposed over the years. However, most open source solutions do not take full advantage of integrated circuit (IC) potentiostats, a rapidly evolving field. This is partly due to the constraining requirements inherent to the development of dedicated interfaces, such as apps, to address and control a set of common electrochemical sensing parameters. Here we propose the PocketEC, a universal app that has all the functionalities to interface with potentiostat ICs through a user defined property file. The versatility of PocketEC, developed with an assay developer mindset, was demonstrated by interfacing it, via Bluetooth, to the ADuCM355 evaluation board, the open-source DStat potentiostat and the Voyager board, a custom-built, small footprint potentiostat based around the LMP91000 chip. The Voyager board is presented here for the first time. Data obtained using a standard redox probe, Ferrocene Carboxylic Acid (FCA) and a silver ion assay using anodic stripping multi-step amperometry were in good agreement with analogous measurements using a bench top potentiostat. Combined with its Voyager board companion, the PocketEC app can be used directly for a number of wearable or portable electrochemical sensing applications. Importantly, the versatility of the app makes it a candidate of choice for the development of future portable potentiostats. Finally, the app is available to download on the Google Play store and the source codes and design files for the PocketEC app and the Voyager board are shared via Creative Commons license (CC BY-NC 3.0) to promote the development of novel portable or wearable applications based on electrochemical sensing.
Collapse
Affiliation(s)
| | - Rui Rodrigues
- Institute of Digital Healthcare, WMG, University of Warwick, Coventry, CV4 7AL, UK.
| | - Sara Sadati
- Institute of Digital Healthcare, WMG, University of Warwick, Coventry, CV4 7AL, UK.
| | - Marcus J Swann
- 5D Health Protection Group Ltd, Accelerator Building, 1 Daulby Street, Liverpool L7 8XZ, UK
| | - Neville Freeman
- 5D Health Protection Group Ltd, Accelerator Building, 1 Daulby Street, Liverpool L7 8XZ, UK
| | - Bowen Du
- Institute of Digital Healthcare, WMG, University of Warwick, Coventry, CV4 7AL, UK.
| | - Ender Yildirim
- Middle East Technical University, Mechanical Engineering Department, 06800, Ankara, Turkey
| | - Ugur Tamer
- Department of Analytical Chemistry, Faculty of Pharmacy, Gazi University, Ankara, 06330, Turkey
| | - Theodoros N Arvanitis
- Institute of Digital Healthcare, WMG, University of Warwick, Coventry, CV4 7AL, UK.
- School of Engineering, University of Birmingham, Edgbaston, Birmingham, B15 2TT, UK
| | - Dmitry Isakov
- Institute of Digital Healthcare, WMG, University of Warwick, Coventry, CV4 7AL, UK.
| | - Ali Asadipour
- Computer Science Research Centre, Royal College of Art, London, SW7 2EU, UK.
| | - Jérôme Charmet
- Institute of Digital Healthcare, WMG, University of Warwick, Coventry, CV4 7AL, UK.
- Warwick Medical School, University of Warwick, Coventry, CV4 7AL, UK
- HE-Arc Ingénierie, HES-SO University of Applied Sciences and Art of Western Switzerland, 2000 Neuchâtel, Switzerland
| |
Collapse
|
13
|
Ming J, Zeng X, Zhou R. Portable biosensor-based oral pathogenic bacteria detection for community and family applications. Anal Bioanal Chem 2023:10.1007/s00216-023-04809-1. [PMID: 37389598 DOI: 10.1007/s00216-023-04809-1] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/19/2023] [Revised: 06/14/2023] [Accepted: 06/15/2023] [Indexed: 07/01/2023]
Abstract
Detection of oral pathogens is essential in the management of oral diseases, as their occurrence and progression are closely linked to an imbalance in these microorganisms. Detection techniques such as microbial cultures, enzyme-linked immunosorbent assays and polymerase chain reactions are highly dependent on complex testing procedures and specialized laboratory equipment, making prevention and early diagnosis of oral diseases difficult. To comprehensively implement oral disease prevention and early diagnosis in social groups, there is an urgent need for portable testing methods for oral pathogenic bacteria that can be applied in community and home settings. In this review, several common portable biosensors for pathogenic bacteria are first described. Based on the goal of achieving primary prevention and diagnosis of oral diseases, we elaborate and summarize portable biosensors for common oral pathogenic bacteria in terms of how to achieve portability of the technique. This review aims to reflect the current status of portable biosensors for common oral pathogens and to lay the foundation for the further realization of portable detection of oral pathogens.
Collapse
Affiliation(s)
- Jieyu Ming
- State Key Laboratory of Oral Diseases, National Clinical Research Center for Oral Diseases, Chinese Academy of Medical Sciences Research Unit of Oral Carcinogenesis and Management, West China Hospital of Stomatology, Sichuan University, Chengdu, Sichuan, 610041, People's Republic of China
| | - Xin Zeng
- State Key Laboratory of Oral Diseases, National Clinical Research Center for Oral Diseases, Chinese Academy of Medical Sciences Research Unit of Oral Carcinogenesis and Management, West China Hospital of Stomatology, Sichuan University, Chengdu, Sichuan, 610041, People's Republic of China.
| | - Ronghui Zhou
- State Key Laboratory of Oral Diseases, National Clinical Research Center for Oral Diseases, Chinese Academy of Medical Sciences Research Unit of Oral Carcinogenesis and Management, West China Hospital of Stomatology, Sichuan University, Chengdu, Sichuan, 610041, People's Republic of China.
| |
Collapse
|
14
|
VURAL B, ULUDAĞ İ, İNCE B, ÖZYURT C, ÖZTÜRK F, SEZGİNTÜRK MK. Fluid-based wearable sensors: a turning point in personalized healthcare. Turk J Chem 2023; 47:944-967. [PMID: 38173754 PMCID: PMC10760819 DOI: 10.55730/1300-0527.3588] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/15/2023] [Revised: 10/31/2023] [Accepted: 05/22/2023] [Indexed: 01/05/2024] Open
Abstract
Nowadays, it has become very popular to develop wearable devices that can monitor biomarkers to analyze the health status of the human body more comprehensively and accurately. Wearable sensors, specially designed for home care services, show great promise with their ease of use, especially during pandemic periods. Scientists have conducted many innovative studies on new wearable sensors that can noninvasively and simultaneously monitor biochemical indicators in body fluids for disease prediction, diagnosis, and management. Using noninvasive electrochemical sensors, biomarkers can be detected in tears, saliva, perspiration, and skin interstitial fluid (ISF). In this review, biofluids used for noninvasive wearable sensor detection under four main headings, saliva, sweat, tears, and ISF-based wearable sensors, were examined in detail. This report analyzes nearly 50 recent articles from 2017 to 2023. Based on current research, this review also discusses the evolution of wearable sensors, potential implementation challenges, and future prospects.
Collapse
Affiliation(s)
- Berfin VURAL
- Department of Bioengineering, Faculty of Engineering, Çanakkale Onsekiz Mart University, Çanakkale,
Turkiye
| | - İnci ULUDAĞ
- Department of Bioengineering, Faculty of Engineering, Çanakkale Onsekiz Mart University, Çanakkale,
Turkiye
| | - Bahar İNCE
- Department of Bioengineering, Faculty of Engineering, Çanakkale Onsekiz Mart University, Çanakkale,
Turkiye
| | - Canan ÖZYURT
- Department of Chemistry and Chemical Processing Technologies, Lapseki Vocational School, Çanakkale Onsekiz Mart University, Çanakkale,
Turkiye
| | - Funda ÖZTÜRK
- Department of Chemistry, Faculty of Arts and Sciences, Tekirdağ Namık Kemal University, Tekirdağ,
Turkiye
| | - Mustafa Kemal SEZGİNTÜRK
- Department of Bioengineering, Faculty of Engineering, Çanakkale Onsekiz Mart University, Çanakkale,
Turkiye
| |
Collapse
|
15
|
Mulyaningsih RD, Pratiwi R, Hasanah AN. An Update on the Use of Natural Pigments and Pigment Nanoparticle Adducts for Metal Detection Based on Colour Response. BIOSENSORS 2023; 13:bios13050554. [PMID: 37232915 DOI: 10.3390/bios13050554] [Citation(s) in RCA: 5] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 04/07/2023] [Revised: 05/07/2023] [Accepted: 05/16/2023] [Indexed: 05/27/2023]
Abstract
Natural pigments occur in plants as secondary metabolites and have been used as safe colourants in food. Studies have reported that their unstable colour intensity might be related to metal ion interaction, which leads to the formation of metal-pigment complexes. This underlines the need for further investigations on the use of natural pigments in metal detection using colorimetric methods, since metals are important elements and can be hazardous when present in large amounts. This review aimed to discuss the use of natural pigments (mainly betalains, anthocyanins, curcuminoids, carotenoids, and chlorophyll) as reagents for portable metal detection based on their limits of detection, to determine which pigment is best for certain metals. Colorimetric-related articles over the last decade were gathered, including those involving methodological modifications, sensor developments, and a general overview. When considering sensitivity and portability, the results revealed that betalains are best applied for copper, using a smartphone-assisted sensor; curcuminoids are best applied for lead, using a curcumin nanofiber; and anthocyanin is best applied for mercury, using anthocyanin hydrogel. This provides a new perspective on the use of colour instability for the detection of metals with modern sensor developments. In addition, a coloured sheet representing metal concentrations may be useful as a standard to support on-site detection with trials on masking agents to improve selectivity.
Collapse
Affiliation(s)
- Raspati D Mulyaningsih
- Master Program in Pharmacy, Faculty of Pharmacy, Universitas Padjadjaran, Sumedang 45363, Indonesia
| | - Rimadani Pratiwi
- Department of Pharmaceutical Analysis and Medicinal Chemistry, Faculty of Pharmacy, Universitas Padjadjaran, Sumedang 45363, Indonesia
- Drug Development Study Centre, Faculty of Pharmacy, Universitas Padjadjaran, Sumedang 45363, Indonesia
| | - Aliya N Hasanah
- Department of Pharmaceutical Analysis and Medicinal Chemistry, Faculty of Pharmacy, Universitas Padjadjaran, Sumedang 45363, Indonesia
- Drug Development Study Centre, Faculty of Pharmacy, Universitas Padjadjaran, Sumedang 45363, Indonesia
| |
Collapse
|
16
|
Saiki T, Ogata G, Sawamura S, Asai K, Razvina O, Watanabe K, Kato R, Zhang Q, Akiyama K, Madhurantakam S, Ahmad NB, Ino D, Nashimoto H, Matsumoto Y, Moriyama M, Horii A, Kondo C, Ochiai R, Kusuhara H, Saijo Y, Einaga Y, Hibino H. A strategy for low-cost portable monitoring of plasma drug concentrations using a sustainable boron-doped-diamond chip. Heliyon 2023; 9:e15963. [PMID: 37234605 PMCID: PMC10205593 DOI: 10.1016/j.heliyon.2023.e15963] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/26/2022] [Revised: 04/20/2023] [Accepted: 04/27/2023] [Indexed: 05/28/2023] Open
Abstract
On-site monitoring of plasma drug concentrations is required for effective therapies. Recently developed handy biosensors are not yet popular owing to insufficient evaluation of accuracy on clinical samples and the necessity of complicated costly fabrication processes. Here, we approached these bottlenecks via a strategy involving engineeringly unmodified boron-doped diamond (BDD), a sustainable electrochemical material. A sensing system based on a ∼1 cm2 BDD chip, when analysing rat plasma spiked with a molecular-targeting anticancer drug, pazopanib, detected clinically relevant concentrations. The response was stable in 60 sequential measurements on the same chip. In a clinical study, data obtained with a BDD chip were consistent with liquid chromatography-mass spectrometry results. Finally, the portable system with a palm-sized sensor containing the chip analysed ∼40 μL of whole blood from dosed rats within ∼10 min. This approach with the 'reusable' sensor may improve point-of-monitoring systems and personalised medicine while reducing medical costs.
Collapse
Affiliation(s)
- Takuro Saiki
- Department of Medical Oncology, Niigata University Graduate School of Medical and Dental Sciences, 1-757 Asahimachi-dori Chuo-ku, Niigata, Niigata 951-8510, Japan
| | - Genki Ogata
- Department of Chemistry, Keio University, 3-14-1 Hiyoshi, Yokohama, Kanagawa 223-8522, Japan
| | - Seishiro Sawamura
- Division of Glocal Pharmacology, Department of Pharmacology, Graduate School of Medicine, Osaka University, 2-2 Yamadaoka, Suita, Osaka 565-0871, Japan
| | - Kai Asai
- Department of Chemistry, Keio University, 3-14-1 Hiyoshi, Yokohama, Kanagawa 223-8522, Japan
| | - Olga Razvina
- G-MedEx Project, Niigata University Graduate School of Medical and Dental Sciences, 1-757 Asahimachi-dori Chuo-ku, Niigata, Niigata 951-8510, Japan
| | - Kota Watanabe
- Niigata University School of Medicine, 1-757 Asahimachi-dori Chuo-ku, Niigata, Niigata 951-8510, Japan
| | - Rito Kato
- Niigata University School of Medicine, 1-757 Asahimachi-dori Chuo-ku, Niigata, Niigata 951-8510, Japan
| | - Qi Zhang
- Division of Glocal Pharmacology, Department of Pharmacology, Graduate School of Medicine, Osaka University, 2-2 Yamadaoka, Suita, Osaka 565-0871, Japan
- Department of Otolaryngology Head and Neck Surgery, Niigata University Graduate School of Medical and Dental Sciences, 1-757 Asahimachi-dori Chuo-ku, Niigata, Niigata 951-8510, Japan
| | - Koei Akiyama
- Division of Glocal Pharmacology, Department of Pharmacology, Graduate School of Medicine, Osaka University, 2-2 Yamadaoka, Suita, Osaka 565-0871, Japan
- Department of Molecular Physiology, Niigata University Graduate School of Medical and Dental Sciences, 1-757 Asahimachi-dori Chuo-ku, Niigata, Niigata 951-8510, Japan
| | - Sasya Madhurantakam
- Division of Glocal Pharmacology, Department of Pharmacology, Graduate School of Medicine, Osaka University, 2-2 Yamadaoka, Suita, Osaka 565-0871, Japan
| | - Norzahirah Binti Ahmad
- Division of Glocal Pharmacology, Department of Pharmacology, Graduate School of Medicine, Osaka University, 2-2 Yamadaoka, Suita, Osaka 565-0871, Japan
| | - Daisuke Ino
- Division of Glocal Pharmacology, Department of Pharmacology, Graduate School of Medicine, Osaka University, 2-2 Yamadaoka, Suita, Osaka 565-0871, Japan
| | - Haruma Nashimoto
- Laboratory of Molecular Pharmacokinetics, Graduate School of Pharmaceutical Sciences, The University of Tokyo, 7-3-1, Hongo, Bunkyo, Tokyo 113-0033, Japan
| | - Yoshifumi Matsumoto
- Department of Medical Oncology, Niigata University Graduate School of Medical and Dental Sciences, 1-757 Asahimachi-dori Chuo-ku, Niigata, Niigata 951-8510, Japan
| | - Masato Moriyama
- Department of Medical Oncology, Niigata University Graduate School of Medical and Dental Sciences, 1-757 Asahimachi-dori Chuo-ku, Niigata, Niigata 951-8510, Japan
| | - Arata Horii
- Department of Otolaryngology Head and Neck Surgery, Niigata University Graduate School of Medical and Dental Sciences, 1-757 Asahimachi-dori Chuo-ku, Niigata, Niigata 951-8510, Japan
| | - Chie Kondo
- Pharmaceuticals and Life Sciences Division, Shimadzu Techno-Research, Inc., 1, Nishinokyo-shimoai-cho, Nakagyo-ku, Kyoto, Kyoto 604-8436, Japan
| | - Ryosuke Ochiai
- Pharmaceuticals and Life Sciences Division, Shimadzu Techno-Research, Inc., 1, Nishinokyo-shimoai-cho, Nakagyo-ku, Kyoto, Kyoto 604-8436, Japan
| | - Hiroyuki Kusuhara
- Laboratory of Molecular Pharmacokinetics, Graduate School of Pharmaceutical Sciences, The University of Tokyo, 7-3-1, Hongo, Bunkyo, Tokyo 113-0033, Japan
| | - Yasuo Saijo
- Department of Medical Oncology, Niigata University Graduate School of Medical and Dental Sciences, 1-757 Asahimachi-dori Chuo-ku, Niigata, Niigata 951-8510, Japan
| | - Yasuaki Einaga
- Department of Chemistry, Keio University, 3-14-1 Hiyoshi, Yokohama, Kanagawa 223-8522, Japan
| | - Hiroshi Hibino
- Division of Glocal Pharmacology, Department of Pharmacology, Graduate School of Medicine, Osaka University, 2-2 Yamadaoka, Suita, Osaka 565-0871, Japan
- AMED-CREST, AMED, Osaka 565-0871, Japan
| |
Collapse
|
17
|
Holman JB, Shi Z, Fadahunsi AA, Li C, Ding W. Advances on microfluidic paper-based electroanalytical devices. Biotechnol Adv 2023; 63:108093. [PMID: 36603801 DOI: 10.1016/j.biotechadv.2022.108093] [Citation(s) in RCA: 12] [Impact Index Per Article: 6.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/03/2022] [Revised: 12/30/2022] [Accepted: 12/30/2022] [Indexed: 01/03/2023]
Abstract
Since the inception of the first electrochemical devices on paper substrates, many different reports of microfluidic paper-based electroanalytical devices (μPEDs), innovative hydrophobic barriers and electrode fabrication processes have allowed the incorporation of diverse materials, resulting in different applications and a boost in performance. These advancements have led to the creation of paper-based devices with comparable performance to many standard conventional devices, with the added benefits of pumpless fluidic transport, component separation and reagent storage that can be exploited to automate and handle sample preprocessing. Herein, we review μPEDs, summarize the characteristics and functionalities of μPEDs, such as separation, fluid flow control and storage, and outline the conventional and emerging fabrication and modification approaches for μPEDs. We also examine the recent application of μPEDs in biomedicine, the environment, and food and water safety, as well as some limitations and challenges that must be addressed.
Collapse
Affiliation(s)
- Joseph Benjamin Holman
- School of Information Science and Technology, University of Science and Technology of China, Hefei, Anhui 230027, China
| | - Zhengdi Shi
- School of Information Science and Technology, University of Science and Technology of China, Hefei, Anhui 230027, China
| | - Adeola A Fadahunsi
- School of Information Science and Technology, University of Science and Technology of China, Hefei, Anhui 230027, China
| | - Chengpan Li
- School of Information Science and Technology, University of Science and Technology of China, Hefei, Anhui 230027, China.
| | - Weiping Ding
- Department of Oncology, the First Affiliated Hospital of USTC, Division of Life Sciences and Medicine, University of Science and Technology of China, Hefei, Anhui 230001, China.
| |
Collapse
|
18
|
Guo W, Tao Y, Mao K, Liu W, Xue R, Ge Z, Ren Y. Portable general microfluidic device with complex electric field regulation functions for electrokinetic experiments. LAB ON A CHIP 2022; 23:157-167. [PMID: 36484422 DOI: 10.1039/d2lc01053d] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/17/2023]
Abstract
Electrokinetic sample manipulation is a key step for many kinds of microfluidic chips to achieve various functions, such as particle focusing and separation, fluid pumping and material synthesis. But these microfluidic experiments usually rely on large-scale signal generators for power supply, microscopes for imaging and other instruments for analysis, which hampers the portable process of microfluidic technology. Inspired by this situation, we herein designed a portable general microfluidic device (PGMD) with complex electric field regulation functions, which can accurately regulate static or continuous fluid samples. Through the graphical user interface (GUI) and modular design, the PGMD can generate multiple different electrical signals, and the micro-flow of fluid can be pumped through the built-in micropump, which can meet the requirements of most microfluidic experiments. Photos or videos of the microfluidic chip captured by the built-in microscope are received and displayed by a smartphone. We carried out a variety of microfluidic experiments such as induced-charge electroosmosis (ICEO), particle beam exit switching, thermal buoyancy flow and dielectrophoresis (DEP) on the PGMD. In addition, the PGMD can perform rapid microalgae concentration estimation in an outdoor environment, which can be used to guide microalgae cultivation, further demonstrating the development potential of this device in the field of microbial applications. Numerous results show that the PGMD has a high degree of integration and strong reliability, which expands the application of microfluidic electrokinetic experiments and provides technical support for the integration and portability of microfluidic experimental devices.
Collapse
Affiliation(s)
- Wenshang Guo
- State Key Laboratory of Robotics and System, Harbin Institute of Technology, West Da-zhi Street 92, Harbin, Heilongjiang 150001, People's Republic of China.
| | - Ye Tao
- State Key Laboratory of Robotics and System, Harbin Institute of Technology, West Da-zhi Street 92, Harbin, Heilongjiang 150001, People's Republic of China.
| | - Kaihao Mao
- State Key Laboratory of Robotics and System, Harbin Institute of Technology, West Da-zhi Street 92, Harbin, Heilongjiang 150001, People's Republic of China.
| | - Weiyu Liu
- School of Electronics and Control Engineering, Chang'an University, Middle-Section of Nan'er Huan Road, Xi'an 710000, China
| | - Rui Xue
- State Key Laboratory of Robotics and System, Harbin Institute of Technology, West Da-zhi Street 92, Harbin, Heilongjiang 150001, People's Republic of China.
| | - Zhenyou Ge
- State Key Laboratory of Robotics and System, Harbin Institute of Technology, West Da-zhi Street 92, Harbin, Heilongjiang 150001, People's Republic of China.
| | - Yukun Ren
- State Key Laboratory of Robotics and System, Harbin Institute of Technology, West Da-zhi Street 92, Harbin, Heilongjiang 150001, People's Republic of China.
| |
Collapse
|
19
|
Wu JY, Ching CTS, Wang HMD, Liao LD. Emerging Wearable Biosensor Technologies for Stress Monitoring and Their Real-World Applications. BIOSENSORS 2022; 12:1097. [PMID: 36551064 PMCID: PMC9776100 DOI: 10.3390/bios12121097] [Citation(s) in RCA: 6] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 11/07/2022] [Accepted: 11/15/2022] [Indexed: 06/17/2023]
Abstract
Wearable devices are being developed faster and applied more widely. Wearables have been used to monitor movement-related physiological indices, including heartbeat, movement, and other exercise metrics, for health purposes. People are also paying more attention to mental health issues, such as stress management. Wearable devices can be used to monitor emotional status and provide preliminary diagnoses and guided training functions. The nervous system responds to stress, which directly affects eye movements and sweat secretion. Therefore, the changes in brain potential, eye potential, and cortisol content in sweat could be used to interpret emotional changes, fatigue levels, and physiological and psychological stress. To better assess users, stress-sensing devices can be integrated with applications to improve cognitive function, attention, sports performance, learning ability, and stress release. These application-related wearables can be used in medical diagnosis and treatment, such as for attention-deficit hyperactivity disorder (ADHD), traumatic stress syndrome, and insomnia, thus facilitating precision medicine. However, many factors contribute to data errors and incorrect assessments, including the various wearable devices, sensor types, data reception methods, data processing accuracy and algorithms, application reliability and validity, and actual user actions. Therefore, in the future, medical platforms for wearable devices and applications should be developed, and product implementations should be evaluated clinically to confirm product accuracy and perform reliable research.
Collapse
Affiliation(s)
- Ju-Yu Wu
- Institute of Biomedical Engineering and Nanomedicine, National Health Research Institutes, Zhunan Township, Miaoli County 35053, Taiwan
- Program in Tissue Engineering and Regenerative Medicine, National Chung Hsing University, South District, Taichung City 402, Taiwan
| | - Congo Tak-Shing Ching
- Graduate Institute of Biomedical Engineering, National Chung Hsing University, South District, Taichung City 402, Taiwan
- Department of Electrical Engineering, National Chi Nan University, No. 1 University Road, Puli Township, Nantou County 545301, Taiwan
| | - Hui-Min David Wang
- Program in Tissue Engineering and Regenerative Medicine, National Chung Hsing University, South District, Taichung City 402, Taiwan
- Graduate Institute of Biomedical Engineering, National Chung Hsing University, South District, Taichung City 402, Taiwan
| | - Lun-De Liao
- Institute of Biomedical Engineering and Nanomedicine, National Health Research Institutes, Zhunan Township, Miaoli County 35053, Taiwan
- Program in Tissue Engineering and Regenerative Medicine, National Chung Hsing University, South District, Taichung City 402, Taiwan
| |
Collapse
|
20
|
Screen-printed electrochemical sensors for environmental monitoring of heavy metal ion detection. REV CHEM ENG 2022. [DOI: 10.1515/revce-2022-0002] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/13/2022]
Abstract
Abstract
Heavy metal ions (HMIs) are known to cause severe damages to the human body and ecological environment. And considering the current alarming situation, it is crucial to develop a rapid, sensitive, robust, economical and convenient method for their detection. Screen printed electrochemical technology contributes greatly to this task, and has achieved global attention. It enabled the mass transmission rate and demonstrated ability to control the chemical nature of the measure media. Besides, the technique offers advantages like linear output, quick response, high selectivity, sensitivity and stability along with low power requirement and high signal-to-noise ratio. Recently, the performance of SPEs has been improved employing the most effective and promising method of the incorporation of different nanomaterials into SPEs. Especially, in electrochemical sensors, the incorporation of nanomaterials has gained extensive attention for HMIs detection as it exhibits outstanding features like broad electrochemical window, large surface area, high conductivity, selectivity and stability. The present review focuses on the recent progress in the field of screen-printed electrochemical sensors for HMIs detection using nanomaterials. Different fabrication methods of SPEs and their utilization for real sample analysis of HMIs using various nanomaterials have been extensively discussed. Additionally, advancement made in this field is also discussed taking help of the recent literature.
Collapse
|
21
|
Chauhan S, Dahiya D, Sharma V, Khan N, Chaurasia D, Nadda AK, Varjani S, Pandey A, Bhargava PC. Advances from conventional to real time detection of heavy metal(loid)s for water monitoring: An overview of biosensing applications. CHEMOSPHERE 2022; 307:136124. [PMID: 35995194 DOI: 10.1016/j.chemosphere.2022.136124] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 04/08/2022] [Revised: 08/02/2022] [Accepted: 08/16/2022] [Indexed: 06/15/2023]
Abstract
The rapid growth of the industrial sector has expedited the accumulation of heavy metal(loid)s in the environment at hazardous levels. The elements such as arsenic, lead, mercury, cadmium and chromium are lethal in terms of toxicity with severe health impacts. With issues like water scarcity, limitations in wastewater treatment, and costs pertaining to detection in environmental matrices; their rapid and selective detection for reuse of effluents is of the utmost priority. Biosensors are the futuristic tool for the accurate qualitative and quantitative analysis of a specific analyte and integrate biotechnology, microelectronics and nanotechnology to fabricate a miniaturized device without compromising the sensitivity, specificity and accuracy. The characteristic features of supporting matrix largely affect the biosensing ability of the device and incorporation of highly sensitive and durable metal organic frameworks (MOFs) are reported to enhance the efficiency of advanced biosensors. Electrochemical biosensors are among the most widely developed biosensors for the detection of heavy metal(loids), while direct electron transfer approach from the recognition element to the electrode has been found to decrease the chances of interference. This review provides an insight into the recent progress in biosensor technologies for the detection of prevalent heavy metal(loid)s; using advanced support systems such as functional metal-based nanomaterials, carbon nanotubes, quantum dots, screen printed electrodes, glass beads etc. The review also delves critically in comparison of various techno-economic studies and the latest advances in biosensor technology.
Collapse
Affiliation(s)
- Shraddha Chauhan
- Aquatic Toxicology Laboratory, Environmental Toxicology Group, CSIR-Indian Institute of Toxicology Research, Vishvigyan Bhawan, 31, Mahatma Gandhi Marg, Lucknow, Uttar Pradesh, 226 001, India
| | - Digvijay Dahiya
- Department of Biotechnology, National Institute of Technology, Andhra Pradesh Tadepalligudem, 534101, India
| | - Vikas Sharma
- Aquatic Toxicology Laboratory, Environmental Toxicology Group, CSIR-Indian Institute of Toxicology Research, Vishvigyan Bhawan, 31, Mahatma Gandhi Marg, Lucknow, Uttar Pradesh, 226 001, India
| | - Nawaz Khan
- Aquatic Toxicology Laboratory, Environmental Toxicology Group, CSIR-Indian Institute of Toxicology Research, Vishvigyan Bhawan, 31, Mahatma Gandhi Marg, Lucknow, Uttar Pradesh, 226 001, India
| | - Deepshi Chaurasia
- Aquatic Toxicology Laboratory, Environmental Toxicology Group, CSIR-Indian Institute of Toxicology Research, Vishvigyan Bhawan, 31, Mahatma Gandhi Marg, Lucknow, Uttar Pradesh, 226 001, India
| | - Ashok Kumar Nadda
- Department of Biotechnology and Bioinformatics, Jaypee University of Information Technology, Waknaghat, Solan, 173 234, India
| | | | - Ashok Pandey
- Centre for Innovation and Translational Research, CSIR-Indian Institute of Toxicology Research (CSIR-IITR), Vishvigyan Bhawan, 31, Mahatma Gandhi Marg, Lucknow, Uttar Pradesh, 226001, India; Centre for Energy and Environmental Sustainability, Lucknow, Uttar Pradesh, 226029, India; Sustainability Cluster, School of Engineering, University of Petroleum and Energy Studies, Dehradun, 248007, Uttarakhand, India
| | - Preeti Chaturvedi Bhargava
- Aquatic Toxicology Laboratory, Environmental Toxicology Group, CSIR-Indian Institute of Toxicology Research, Vishvigyan Bhawan, 31, Mahatma Gandhi Marg, Lucknow, Uttar Pradesh, 226 001, India.
| |
Collapse
|
22
|
Khosla NK, Lesinski JM, Colombo M, Bezinge L, deMello AJ, Richards DA. Simplifying the complex: accessible microfluidic solutions for contemporary processes within in vitro diagnostics. LAB ON A CHIP 2022; 22:3340-3360. [PMID: 35984715 PMCID: PMC9469643 DOI: 10.1039/d2lc00609j] [Citation(s) in RCA: 14] [Impact Index Per Article: 4.7] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 07/06/2022] [Accepted: 08/15/2022] [Indexed: 05/02/2023]
Abstract
In vitro diagnostics (IVDs) form the cornerstone of modern medicine. They are routinely employed throughout the entire treatment pathway, from initial diagnosis through to prognosis, treatment planning, and post-treatment surveillance. Given the proven links between high quality diagnostic testing and overall health, ensuring broad access to IVDs has long been a focus of both researchers and medical professionals. Unfortunately, the current diagnostic paradigm relies heavily on centralized laboratories, complex and expensive equipment, and highly trained personnel. It is commonly assumed that this level of complexity is required to achieve the performance necessary for sensitive and specific disease diagnosis, and that making something affordable and accessible entails significant compromises in test performance. However, recent work in the field of microfluidics is challenging this notion. By exploiting the unique features of microfluidic systems, researchers have been able to create progressively simple devices that can perform increasingly complex diagnostic assays. This review details how microfluidic technologies are disrupting the status quo, and facilitating the development of simple, affordable, and accessible integrated IVDs. Importantly, we discuss the advantages and limitations of various approaches, and highlight the remaining challenges within the field.
Collapse
Affiliation(s)
- Nathan K Khosla
- Institute for Chemical and Bioengineering, ETH Zürich, Vladimir Prelog Weg 1, Zürich, 8093, Switzerland.
| | - Jake M Lesinski
- Institute for Chemical and Bioengineering, ETH Zürich, Vladimir Prelog Weg 1, Zürich, 8093, Switzerland.
| | - Monika Colombo
- Institute for Chemical and Bioengineering, ETH Zürich, Vladimir Prelog Weg 1, Zürich, 8093, Switzerland.
| | - Léonard Bezinge
- Institute for Chemical and Bioengineering, ETH Zürich, Vladimir Prelog Weg 1, Zürich, 8093, Switzerland.
| | - Andrew J deMello
- Institute for Chemical and Bioengineering, ETH Zürich, Vladimir Prelog Weg 1, Zürich, 8093, Switzerland.
| | - Daniel A Richards
- Institute for Chemical and Bioengineering, ETH Zürich, Vladimir Prelog Weg 1, Zürich, 8093, Switzerland.
| |
Collapse
|
23
|
Role of Paper-Based Sensors in Fight against Cancer for the Developing World. BIOSENSORS 2022; 12:bios12090737. [PMID: 36140122 PMCID: PMC9496559 DOI: 10.3390/bios12090737] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 07/22/2022] [Revised: 08/25/2022] [Accepted: 08/31/2022] [Indexed: 11/17/2022]
Abstract
Cancer is one of the major killers across the globe. According to the WHO, more than 10 million people succumbed to cancer in the year 2020 alone. The early detection of cancer is key to reducing the mortality rate. In low- and medium-income countries, the screening facilities are limited due to a scarcity of resources and equipment. Paper-based microfluidics provide a platform for a low-cost, biodegradable micro-total analysis system (µTAS) that can be used for the detection of critical biomarkers for cancer screening. This work aims to review and provide a perspective on various available paper-based methods for cancer screening. The work includes an overview of paper-based sensors, the analytes that can be detected and the detection, and readout methods used.
Collapse
|
24
|
Nanomaterial-Based Electrochemical Nanodiagnostics for Human and Gut Metabolites Diagnostics: Recent Advances and Challenges. BIOSENSORS 2022; 12:bios12090733. [PMID: 36140118 PMCID: PMC9496054 DOI: 10.3390/bios12090733] [Citation(s) in RCA: 7] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 08/02/2022] [Revised: 08/27/2022] [Accepted: 08/31/2022] [Indexed: 11/29/2022]
Abstract
Metabolites are the intermediatory products of metabolic processes catalyzed by numerous enzymes found inside the cells. Detecting clinically relevant metabolites is important to understand their physiological and biological functions along with the evolving medical diagnostics. Rapid advances in detecting the tiny metabolites such as biomarkers that signify disease hallmarks have an immense need for high-performance identifying techniques. Low concentrations are found in biological fluids because the metabolites are difficult to dissolve in an aqueous medium. Therefore, the selective and sensitive study of metabolites as biomarkers in biological fluids is problematic. The different non-electrochemical and conventional methods need a long time of analysis, long sampling, high maintenance costs, and costly instrumentation. Hence, employing electrochemical techniques in clinical examination could efficiently meet the requirements of fully automated, inexpensive, specific, and quick means of biomarker detection. The electrochemical methods are broadly utilized in several emerging and established technologies, and electrochemical biosensors are employed to detect different metabolites. This review describes the advancement in electrochemical sensors developed for clinically associated human metabolites, including glucose, lactose, uric acid, urea, cholesterol, etc., and gut metabolites such as TMAO, TMA, and indole derivatives. Different sensing techniques are evaluated for their potential to achieve relevant degrees of multiplexing, specificity, and sensitivity limits. Moreover, we have also focused on the opportunities and remaining challenges for integrating the electrochemical sensor into the point-of-care (POC) devices.
Collapse
|
25
|
Lee SCH, Burke PJ. NanoStat: An open source, fully wireless potentiostat. Electrochim Acta 2022. [DOI: 10.1016/j.electacta.2022.140481] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/03/2022]
|
26
|
Salvadori K, Páleš JM, Shishkanova TV, Trchová M, Fajgar R, Matějka P, Cuřínová P. An Electrochemical Sensor for Detection of Neuroblastoma Markers: Complexation Studies as a Tool for the Selection of a Suitable Receptor for Electrode Coating. Chempluschem 2022; 87:e202200165. [DOI: 10.1002/cplu.202200165] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/10/2022] [Revised: 07/02/2022] [Indexed: 11/11/2022]
Affiliation(s)
- Karolína Salvadori
- Institute of Chemical Process Fundamentals Czech Academy of Sciences: Ustav chemickych procesu Akademie Ved Ceske Republiky analytical chemistry Rozvojová 135 16502 Prague CZECH REPUBLIC
| | - Jakub Marián Páleš
- Institute of Chemical Process Fundamentals Czech Academy of Sciences: Ustav chemickych procesu Akademie Ved Ceske Republiky analytical chemistry Rozvojová 135 16502 Prague CZECH REPUBLIC
| | - Tatiana V. Shishkanova
- University of Chemistry and Technology Prague: Vysoka skola chemicko-technologicka v Praze analytical chemistry Technická 5 16628 Prague CZECH REPUBLIC
| | - Miroslava Trchová
- University of Chemistry and Technology Prague: Vysoka skola chemicko-technologicka v Praze analytical chemistry Technická 5 16628 Prague CZECH REPUBLIC
| | - Radek Fajgar
- Institute of Chemical Process Fundamentals Czech Academy of Sciences: Ustav chemickych procesu Akademie Ved Ceske Republiky analytical chemistry Rozvojová 135 16502 Prague CZECH REPUBLIC
| | - Pavel Matějka
- University of Chemistry and Technology Prague: Vysoka skola chemicko-technologicka v Praze physical chemistry Technická 5 16628 Prague CZECH REPUBLIC
| | - Petra Cuřínová
- Institute of Chemical Process Fundamentals Czech Academy of Sciences: Ustav chemickych procesu Akademie Ved Ceske Republiky analytical chemistry Rozvojová 135 16502 Praha CZECH REPUBLIC
| |
Collapse
|
27
|
Xiao M, Tian F, Liu X, Zhou Q, Pan J, Luo Z, Yang M, Yi C. Virus Detection: From State-of-the-Art Laboratories to Smartphone-Based Point-of-Care Testing. ADVANCED SCIENCE (WEINHEIM, BADEN-WURTTEMBERG, GERMANY) 2022; 9:e2105904. [PMID: 35393791 PMCID: PMC9110880 DOI: 10.1002/advs.202105904] [Citation(s) in RCA: 77] [Impact Index Per Article: 25.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 12/20/2021] [Revised: 02/27/2022] [Indexed: 05/07/2023]
Abstract
Infectious virus outbreaks pose a significant challenge to public healthcare systems. Early and accurate virus diagnosis is critical to prevent the spread of the virus, especially when no specific vaccine or effective medicine is available. In clinics, the most commonly used viral detection methods are molecular techniques that involve the measurement of nucleic acids or proteins biomarkers. However, most clinic-based methods require complex infrastructure and expensive equipment, which are not suitable for low-resource settings. Over the past years, smartphone-based point-of-care testing (POCT) has rapidly emerged as a potential alternative to laboratory-based clinical diagnosis. This review summarizes the latest development of virus detection. First, laboratory-based and POCT-based viral diagnostic techniques are compared, both of which rely on immunosensing and nucleic acid detection. Then, various smartphone-based POCT diagnostic techniques, including optical biosensors, electrochemical biosensors, and other types of biosensors are discussed. Moreover, this review covers the development of smartphone-based POCT diagnostics for various viruses including COVID-19, Ebola, influenza, Zika, HIV, et al. Finally, the prospects and challenges of smartphone-based POCT diagnostics are discussed. It is believed that this review will aid researchers better understand the current challenges and prospects for achieving the ultimate goal of containing disease-causing viruses worldwide.
Collapse
Affiliation(s)
- Meng Xiao
- Guangdong Provincial Key Laboratory of Sensing Technology and Biomedical Instrument, School of Biomedical EngineeringShenzhen Campus of Sun Yat‐Sen UniversityShenzhen518107P. R. China
| | - Feng Tian
- Department of Biomedical EngineeringThe Hong Kong Polytechnic UniversityHunghomHong Kong999077P. R. China
| | - Xin Liu
- Guangdong Provincial Key Laboratory of Sensing Technology and Biomedical Instrument, School of Biomedical EngineeringShenzhen Campus of Sun Yat‐Sen UniversityShenzhen518107P. R. China
| | - Qiaoqiao Zhou
- Guangdong Provincial Key Laboratory of Sensing Technology and Biomedical Instrument, School of Biomedical EngineeringShenzhen Campus of Sun Yat‐Sen UniversityShenzhen518107P. R. China
| | - Jiangfei Pan
- Guangdong Provincial Key Laboratory of Sensing Technology and Biomedical Instrument, School of Biomedical EngineeringShenzhen Campus of Sun Yat‐Sen UniversityShenzhen518107P. R. China
| | - Zhaofan Luo
- Department of Clinical LaboratoryThe Seventh Affiliated Hospital of Sun Yat‐Sen UniversityShenzhen518107P. R. China
| | - Mo Yang
- Department of Biomedical EngineeringThe Hong Kong Polytechnic UniversityHunghomHong Kong999077P. R. China
| | - Changqing Yi
- Guangdong Provincial Key Laboratory of Sensing Technology and Biomedical Instrument, School of Biomedical EngineeringShenzhen Campus of Sun Yat‐Sen UniversityShenzhen518107P. R. China
| |
Collapse
|
28
|
Chozinski T, Ferguson BS, Fisher W, Ge S, Gong Q, Kang H, McDermott J, Scott A, Shi W, Trausch JJ, Verch T, Vukovich M, Wang J, Wu JE, Yang Q. Development of an Aptamer-Based Electrochemical Microfluidic Device for Viral Vaccine Quantitation. Anal Chem 2022; 94:6146-6155. [PMID: 35410467 DOI: 10.1021/acs.analchem.1c05093] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/26/2022]
Abstract
Global deployment of vaccines poses significant challenges in the distribution and use of the accompanying immunoassays, one of the standard methods for quality control of vaccines, particularly when establishing assays in countries worldwide to support testing/release upon importation. This work describes our effort toward developing an integrated, portable device to carry out affinity assays for viral particles quantification in viral vaccines by incorporating (i) aptamers, (ii) microfluidic devices, and (iii) electrochemical detection. We generated and characterized more than eight aptamers against multiple membrane proteins of cytomegalovirus (CMV), which we used as a model system and designed and fabricated electrochemical microfluidic devices to measure CMV concentrations in a candidate vaccine under development. The aptamer-based assays provided a half maximal effective concentration, EC50, of 12 U/mL, comparable to that of an ELISA using a pair of antibodies (EC50 60 U/mL). The device measured relative CMV concentrations accurately (within ±10% bias) and precisely (11%, percent relative standard deviation). This work represents the critical first steps toward developing simple, affordable, and robust affinity assays for global deployment without the need for sensitive equipment and extensive analyst training.
Collapse
Affiliation(s)
- Tyler Chozinski
- Aptitude Medical Systems, 125 Cremona Drive, Suite 100, Goleta, California 93117, United States
| | - B Scott Ferguson
- Aptitude Medical Systems, 125 Cremona Drive, Suite 100, Goleta, California 93117, United States
| | - William Fisher
- Aptitude Medical Systems, 125 Cremona Drive, Suite 100, Goleta, California 93117, United States
| | - Shencheng Ge
- Merck & Co., Inc., 770 Sumneytown Pike, West Point, Pennsylvania 19486, United States
| | - Qiang Gong
- Aptitude Medical Systems, 125 Cremona Drive, Suite 100, Goleta, California 93117, United States
| | - Hui Kang
- Aptitude Medical Systems, 125 Cremona Drive, Suite 100, Goleta, California 93117, United States
| | - John McDermott
- Aptitude Medical Systems, 125 Cremona Drive, Suite 100, Goleta, California 93117, United States
| | - Alexander Scott
- Aptitude Medical Systems, 125 Cremona Drive, Suite 100, Goleta, California 93117, United States
| | - Wentao Shi
- Aptitude Medical Systems, 125 Cremona Drive, Suite 100, Goleta, California 93117, United States
| | - Jeremiah J Trausch
- Merck & Co., Inc., 770 Sumneytown Pike, West Point, Pennsylvania 19486, United States
| | - Thorsten Verch
- Merck & Co., Inc., 770 Sumneytown Pike, West Point, Pennsylvania 19486, United States
| | - Matthew Vukovich
- Aptitude Medical Systems, 125 Cremona Drive, Suite 100, Goleta, California 93117, United States
| | - Jinpeng Wang
- Aptitude Medical Systems, 125 Cremona Drive, Suite 100, Goleta, California 93117, United States
| | - J Emma Wu
- Aptitude Medical Systems, 125 Cremona Drive, Suite 100, Goleta, California 93117, United States
| | - Qin Yang
- Aptitude Medical Systems, 125 Cremona Drive, Suite 100, Goleta, California 93117, United States
| |
Collapse
|
29
|
A Simple Ratiometric Electrochemical Aptasensor Based on the Thionine–Graphene Nanocomposite for Ultrasensitive Detection of Aflatoxin B2 in Peanut and Peanut Oil. CHEMOSENSORS 2022. [DOI: 10.3390/chemosensors10050154] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 02/05/2023]
Abstract
The accurate and reliable analysis of aflatoxin B2 (AFB2) is widely required in food and agricultural industries. In the present work, we report the first use of a ratiometric electrochemical aptasensor for AFB2 detection with high selectivity and reliability. The working principle relies on the conformation change of the aptamer induced by its specific recognition of AFB2 to vary the ratiometric signal. Based on this principle, the proposed aptasensor collects currents generated by thionine–graphene composites (ITHI) and ferrocene-labeled aptamers (IFc) to output the ratiometric signal of ITHI/IFc. In analysis, the value of ITHI remained stable while that of IFc increased with higher AFB2 concentration, thus offering a “signal-off” aptasensor by using ITHI/IFc as a yardstick. The fabricated aptasensor showed a linear range of 0.001–10 ng mL−1 with a detection limit of 0.19 pg mL−1 for AFB2 detection. Furthermore, its applicability was validated by using it to detect AFB2 in peanut and peanut oil samples with high rates of recovery. The developed ratiometric aptasensor shows the merits of simple fabrication and high accuracy, and it can be extended to detect other mycotoxins in agricultural products.
Collapse
|
30
|
Caux M, Achit A, Var K, Boitel-Aullen G, Rose D, Aubouy A, Argentieri S, Campagnolo R, Maisonhaute E. PassStat, a simple but fast, precise and versatile open source potentiostat. HARDWAREX 2022; 11:e00290. [PMID: 35509918 PMCID: PMC9058825 DOI: 10.1016/j.ohx.2022.e00290] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 11/22/2021] [Revised: 02/08/2022] [Accepted: 03/07/2022] [Indexed: 05/26/2023]
Abstract
This work presents 4 open source potentiostat solutions for performing accurate measurements in cyclic voltammetry and square wave voltammetry at a low price. A very simple and easy to reproduce analogic board (c.a. 10 €) was driven either by a Teensy card from the company PJRC under an Arduino/Python software solution (39 €) or by an Analog Discovery 2 device from Digilent (less than 300 €). A smartphone Bluetooth Android interface was also created to circumvent the use of a computer. We demonstrated that our scheme is suitable for measurements in classical electrochemical conditions but also to carry out experiments with ultramicroelectrodes. We could thus reach a noise resolution of less than 1 pA. Scan rates of 8000 Vs-1 with ohmic drop compensation were also achieved. The device is suitable for teaching purposes but also for experiments in a participative science context on the ground, or countries with lower financial possibilities.
Collapse
Affiliation(s)
- Mélicia Caux
- Sorbonne Université, CNRS, Laboratoire Interfaces et Systèmes Electrochimiques, 4 place Jussieu, 75005 Paris, France
| | - Anis Achit
- Sorbonne Université, CNRS, Laboratoire Interfaces et Systèmes Electrochimiques, 4 place Jussieu, 75005 Paris, France
| | - Kethsovann Var
- Sorbonne Université, CNRS, Laboratoire Interfaces et Systèmes Electrochimiques, 4 place Jussieu, 75005 Paris, France
| | - Gabriel Boitel-Aullen
- Sorbonne Université, CNRS, Laboratoire Interfaces et Systèmes Electrochimiques, 4 place Jussieu, 75005 Paris, France
| | - Daniel Rose
- Sorbonne Université, CNRS, Laboratoire Interfaces et Systèmes Electrochimiques, 4 place Jussieu, 75005 Paris, France
| | - Agnès Aubouy
- UMR152 PHARMADEV, Université de Toulouse, IRD, UPS, France
| | - Sylvain Argentieri
- Sorbonne Université, CNRS, Institut des Systèmes Intelligents et de Robotique, 4 place Jussieu, 75005 Paris, France
| | - Raymond Campagnolo
- Sorbonne Université, CNRS, Laboratoire Interfaces et Systèmes Electrochimiques, 4 place Jussieu, 75005 Paris, France
| | - Emmanuel Maisonhaute
- Sorbonne Université, CNRS, Laboratoire Interfaces et Systèmes Electrochimiques, 4 place Jussieu, 75005 Paris, France
| |
Collapse
|
31
|
Tabasum H, Gill N, Mishra R, Lone S. Wearable microfluidic-based e-skin sweat sensors. RSC Adv 2022; 12:8691-8707. [PMID: 35424805 PMCID: PMC8985157 DOI: 10.1039/d1ra07888g] [Citation(s) in RCA: 19] [Impact Index Per Article: 6.3] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/26/2021] [Accepted: 02/27/2022] [Indexed: 12/20/2022] Open
Abstract
Electronic skins (e-skins) are soft (deformable and stretchable) state-of-the-art wearable devices that emulate the attributes of human skin and act as a Human-Machine Interface (HMI). Recent advances in e-skin for real-time detection of medical signals such as pulse, temperature, electromyogram (EMG), electroencephalogram (EEG), electrooculogram (EOG), electrocardiogram (ECG), and other bioelectric signals laid down an intelligent foundation for early prediction and diagnosis of diseases with a motive of reducing the risk of the ailment reaching to the end stage. In particular, sweat testing has been employed in diverse applications ranging from medical diagnosis of diabetes, cystic fibrosis, tuberculosis, blood pressure, and autonomic neuropathy to evaluating fluid and electrolyte balance in athletes. Typically, sweat testing techniques are done by trained experts and require off-body measurements, which prevent individuals from de-coding health issues quickly and independently. With the onset of soft electronics, wearable sweat sensors overcome this disadvantage via in situ sweat measurements with real-time feedback, timely diagnosis, creating the potential for preventive care and treatment. Over the past few decades, wearable microfluidic-based e-skin sweat sensors have paved a new way, promising sensing interfaces that are highly compatible with arranging medical and electronic applications. The present review highlights the recent research carried out in the microfluidic-based wearable sweat sensors with a critical focus on real-time sensing of lactate, chloride, and glucose concentration; sweat rate, simultaneously with pH, and total sweat loss for preventive care, timely diagnosis, and point-of-care health and fitness monitoring.
Collapse
Affiliation(s)
- Humairah Tabasum
- Department of Chemistry, National Institute of Technology (NIT) Srinagar J&K India 190006 +91-60005221589
- iDREAM (Interdisciplinary Division for Renewable Energy & Advanced Materials), NIT Srinagar India 190006
| | - Nikita Gill
- Department of Chemistry, National Institute of Technology (NIT) Srinagar J&K India 190006 +91-60005221589
- iDREAM (Interdisciplinary Division for Renewable Energy & Advanced Materials), NIT Srinagar India 190006
| | - Rahul Mishra
- Department of Chemistry, National Institute of Technology (NIT) Srinagar J&K India 190006 +91-60005221589
- iDREAM (Interdisciplinary Division for Renewable Energy & Advanced Materials), NIT Srinagar India 190006
| | - Saifullah Lone
- Department of Chemistry, National Institute of Technology (NIT) Srinagar J&K India 190006 +91-60005221589
- iDREAM (Interdisciplinary Division for Renewable Energy & Advanced Materials), NIT Srinagar India 190006
| |
Collapse
|
32
|
Hsieh K, Melendez JH, Gaydos CA, Wang TH. Bridging the gap between development of point-of-care nucleic acid testing and patient care for sexually transmitted infections. LAB ON A CHIP 2022; 22:476-511. [PMID: 35048928 PMCID: PMC9035340 DOI: 10.1039/d1lc00665g] [Citation(s) in RCA: 9] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/14/2023]
Abstract
The incidence rates of sexually transmitted infections (STIs), including the four major curable STIs - chlamydia, gonorrhea, trichomoniasis and, syphilis - continue to increase globally, causing medical cost burden and morbidity especially in low and middle-income countries (LMIC). There have seen significant advances in diagnostic testing, but commercial antigen-based point-of-care tests (POCTs) are often insufficiently sensitive and specific, while near-point-of-care (POC) instruments that can perform sensitive and specific nucleic acid amplification tests (NAATs) are technically complex and expensive, especially for LMIC. Thus, there remains a critical need for NAAT-based STI POCTs that can improve diagnosis and curb the ongoing epidemic. Unfortunately, the development of such POCTs has been challenging due to the gap between researchers developing new technologies and healthcare providers using these technologies. This review aims to bridge this gap. We first present a short introduction of the four major STIs, followed by a discussion on the current landscape of commercial near-POC instruments for the detection of these STIs. We present relevant research toward addressing the gaps in developing NAAT-based STI POCT technologies and supplement this discussion with technologies for HIV and other infectious diseases, which may be adapted for STIs. Additionally, as case studies, we highlight the developmental trajectory of two different POCT technologies, including one approved by the United States Food and Drug Administration (FDA). Finally, we offer our perspectives on future development of NAAT-based STI POCT technologies.
Collapse
Affiliation(s)
- Kuangwen Hsieh
- Department of Mechanical Engineering, Johns Hopkins University, Baltimore, MD 21218, USA.
| | - Johan H Melendez
- Division of Infectious Diseases, Department of Medicine, Johns Hopkins University School of Medicine, Baltimore, MD 21205, USA
| | - Charlotte A Gaydos
- Division of Infectious Diseases, Department of Medicine, Johns Hopkins University School of Medicine, Baltimore, MD 21205, USA
| | - Tza-Huei Wang
- Department of Mechanical Engineering, Johns Hopkins University, Baltimore, MD 21218, USA.
- Department of Biomedical Engineering, Johns Hopkins University, Baltimore, MD 21218, USA
- Institute for NanoBioTechnology, Johns Hopkins University, Baltimore, MD 21218, USA
| |
Collapse
|
33
|
Nate Z, Gill AA, Chauhan R, Karpoormath R. Recent progress in electrochemical sensors for detection and quantification of malaria. Anal Biochem 2022; 643:114592. [DOI: 10.1016/j.ab.2022.114592] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/29/2021] [Revised: 02/02/2022] [Accepted: 02/03/2022] [Indexed: 12/30/2022]
|
34
|
Ji D, Low SS, Zhang D, Liu L, Lu Y, Liu Q. Smartphone-Based Electrochemical System for Biosensors and Biodetection. METHODS IN MOLECULAR BIOLOGY (CLIFTON, N.J.) 2022; 2393:493-514. [PMID: 34837196 DOI: 10.1007/978-1-0716-1803-5_26] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Subscribe] [Scholar Register] [Indexed: 11/24/2022]
Abstract
With the advantages of high popularity, convenient operation, open-source operation systems, high resolution imaging, and excellent computing capabilities, smartphones have been widely used as the core of detection system for calculation, control, and real-time display. Hence, smartphones play an important role in electrochemical detection and optical detection. Smartphone-based electrochemical systems were combined with screen-printed electrode and interdigital electrodes for in situ detection. The electrodes were modified with biomaterials, chemical materials, and nanomaterials for biosensors and biodetection, such as 3-amino phenylboronic acid nanocomposites, graphene, gold nanoparticles, zinc oxide nanoparticles, carbon nanotubes, proteins, peptides, and antibodies. With the modified electrodes, the smartphone-based impedance system was used to detect acetone, bovine serum albumin, human serum albumin, and trinitrotoluene, while smartphone-based amperometric system was employed to monitor glucose, ascorbic acid, dopamine, uric acid, and levodopa. The smartphone-based electrochemical system for biosensors and biodetection has provided miniaturized and portable alternative for diagnosis, which is promising to find application in point-of-care testing (POCT).
Collapse
Affiliation(s)
- Daizong Ji
- Biosensor National Special Laboratory, Key Laboratory for Biomedical Engineering of Education Ministry, Department of Biomedical Engineering, Zhejiang University, Hangzhou, People's Republic of China
| | - Sze Shin Low
- Biosensor National Special Laboratory, Key Laboratory for Biomedical Engineering of Education Ministry, Department of Biomedical Engineering, Zhejiang University, Hangzhou, People's Republic of China
| | - Diming Zhang
- Biosensor National Special Laboratory, Key Laboratory for Biomedical Engineering of Education Ministry, Department of Biomedical Engineering, Zhejiang University, Hangzhou, People's Republic of China
| | - Lei Liu
- Biosensor National Special Laboratory, Key Laboratory for Biomedical Engineering of Education Ministry, Department of Biomedical Engineering, Zhejiang University, Hangzhou, People's Republic of China
| | - Yanli Lu
- Biosensor National Special Laboratory, Key Laboratory for Biomedical Engineering of Education Ministry, Department of Biomedical Engineering, Zhejiang University, Hangzhou, People's Republic of China
| | - Qingjun Liu
- Biosensor National Special Laboratory, Key Laboratory for Biomedical Engineering of Education Ministry, Department of Biomedical Engineering, Zhejiang University, Hangzhou, People's Republic of China.
| |
Collapse
|
35
|
Thapa K, Liu W, Wang R. Nucleic acid-based electrochemical biosensor: Recent advances in probe immobilization and signal amplification strategies. WILEY INTERDISCIPLINARY REVIEWS-NANOMEDICINE AND NANOBIOTECHNOLOGY 2021; 14:e1765. [PMID: 34734485 DOI: 10.1002/wnan.1765] [Citation(s) in RCA: 26] [Impact Index Per Article: 6.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 02/15/2021] [Revised: 08/06/2021] [Accepted: 10/04/2021] [Indexed: 12/26/2022]
Abstract
With the increasing importance of accurate and early disease diagnosis and the development of personalized medicine, DNA-based electrochemical biosensor has attracted broad scientific and clinical interests in the past decades due to its unique hybridization specificity, fast response time, and potential for miniaturization. In order to achieve high detection sensitivity, the design of DNA electrochemical biosensors depends critically on the improvement of the accessibility of target molecules and the enhancement of signal readout. Here, we summarize the recent advances in DNA probe immobilization and signal amplification strategies with a special focus on DNA nanostructure-supported DNA probe immobilization method, which provides the opportunity to rationally control the distance between probes and keep them in upright confirmation, as well as the contribution of functional nanomaterials in enhancing the signal amplification. The next challenge of biosensors will be the fabrication of point-of-care devices for clinical testing. The advancement of multidisciplinary areas, including nanofabrication, material science, and biochemistry, has exhibited profound promise in achieving such portable sensing devices. This article is categorized under: Diagnostic Tools > Biosensing Diagnostic Tools > Diagnostic Nanodevices Biology-Inspired Nanomaterials > Nucleic Acid-Based Structures.
Collapse
Affiliation(s)
- Krishna Thapa
- Department of Chemistry, Missouri University of Science and Technology, Rolla, Missouri, USA
| | - Wenyan Liu
- Department of Chemistry, Missouri University of Science and Technology, Rolla, Missouri, USA.,Center for Research in Energy and Environment, Missouri University of Science and Technology, Rolla, Missouri, USA
| | - Risheng Wang
- Department of Chemistry, Missouri University of Science and Technology, Rolla, Missouri, USA
| |
Collapse
|
36
|
Tan J, Wen Y, Li M. Emerging biosensing platforms for quantitative detection of exosomes as diagnostic biomarkers. Coord Chem Rev 2021. [DOI: 10.1016/j.ccr.2021.214111] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/21/2022]
|
37
|
Lu Y, Lan Q, Zhang C, Liu B, Wang X, Xu X, Liang X. Trace-Level Sensing of Phosphate for Natural Soils by a Nano-Screen-Printed Electrode. ENVIRONMENTAL SCIENCE & TECHNOLOGY 2021; 55:13093-13102. [PMID: 34550673 DOI: 10.1021/acs.est.1c05363] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/13/2023]
Abstract
Phosphate as one of the most essential components of living systems, robust analytical techniques available for phosphate sensing in natural waters and soils are essential for monitoring and predicting water quality and agronomic evaluation of phosphate. Using cyclic voltammetry, a point-of-use electrochemical sensor zirconium dioxide/zinc oxide/multiple-wall carbon nanotubes/ammonium molybdate tetrahydrate/screen printed electrode (ZrO2/ZnO/MWCNTs/AMT/SPE) was applied to explore the electro-redox reaction of phosphomolybdate complexes on the surface of electrode, which produced a quantitative electrochemical response of phosphate anions. The modification of the electrode surface with ZrO2/ZnO/MWCNTs nanocomposites is able to generate the electroactive species via chemical reaction between molybdenum (Mo(VI)) and the targeted phosphate anions, leading to a sensitive detection technique for trace phosphate with a lower detection limit (LOD = 2.0 × 10-8 mol L-1), higher reproducibility, anti-interference, and precision in different soil sources. This system will be of great potential to advance the trace-level understanding of phosphate especially in field environmental analysis.
Collapse
Affiliation(s)
- Yuanyuan Lu
- College of Environmental and Resource Sciences, Zhejiang University, 310058 Hangzhou, China
- Key Laboratory of Water Pollution Control and Environmental Security Technology, 310058 Hangzhou, Zhejiang Province, China
- Department of Chemistry, Physical and Theoretical Chemistry Laboratory, Oxford University, South Parks Road, Oxford OX1 3QZ, U.K
| | - Qingwen Lan
- College of Environmental and Resource Sciences, Zhejiang University, 310058 Hangzhou, China
- Key Laboratory of Water Pollution Control and Environmental Security Technology, 310058 Hangzhou, Zhejiang Province, China
| | - Chuxuan Zhang
- College of Environmental and Resource Sciences, Zhejiang University, 310058 Hangzhou, China
- Key Laboratory of Water Pollution Control and Environmental Security Technology, 310058 Hangzhou, Zhejiang Province, China
| | - Boyi Liu
- College of Environmental and Resource Sciences, Zhejiang University, 310058 Hangzhou, China
- Key Laboratory of Water Pollution Control and Environmental Security Technology, 310058 Hangzhou, Zhejiang Province, China
| | - Xiaochun Wang
- College of Environmental and Resource Sciences, Zhejiang University, 310058 Hangzhou, China
- Key Laboratory of Water Pollution Control and Environmental Security Technology, 310058 Hangzhou, Zhejiang Province, China
| | - Xiangyang Xu
- College of Environmental and Resource Sciences, Zhejiang University, 310058 Hangzhou, China
- Key Laboratory of Water Pollution Control and Environmental Security Technology, 310058 Hangzhou, Zhejiang Province, China
| | - Xinqiang Liang
- College of Environmental and Resource Sciences, Zhejiang University, 310058 Hangzhou, China
- Key Laboratory of Water Pollution Control and Environmental Security Technology, 310058 Hangzhou, Zhejiang Province, China
| |
Collapse
|
38
|
Xu J, Fang Y, Chen J. Wearable Biosensors for Non-Invasive Sweat Diagnostics. BIOSENSORS 2021; 11:245. [PMID: 34436047 PMCID: PMC8391966 DOI: 10.3390/bios11080245] [Citation(s) in RCA: 65] [Impact Index Per Article: 16.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 07/06/2021] [Revised: 07/16/2021] [Accepted: 07/20/2021] [Indexed: 12/13/2022]
Abstract
Recent advances in microfluidics, microelectronics, and electrochemical sensing methods have steered the way for the development of novel and potential wearable biosensors for healthcare monitoring. Wearable bioelectronics has received tremendous attention worldwide due to its great a potential for predictive medical modeling and allowing for personalized point-of-care-testing (POCT). They possess many appealing characteristics, for example, lightweight, flexibility, good stretchability, conformability, and low cost. These characteristics make wearable bioelectronics a promising platform for personalized devices. In this paper, we review recent progress in flexible and wearable sensors for non-invasive biomonitoring using sweat as the bio-fluid. Real-time and molecular-level monitoring of personal health states can be achieved with sweat-based or perspiration-based wearable biosensors. The suitability of sweat and its potential in healthcare monitoring, sweat extraction, and the challenges encountered in sweat-based analysis are summarized. The paper also discusses challenges that still hinder the full-fledged development of sweat-based wearables and presents the areas of future research.
Collapse
Affiliation(s)
- Jing Xu
- School of Electrical & Electronic Engineering, North China Electric Power University, Beijing 102206, China;
- Department of Bioengineering, University of California, Los Angeles, Los Angeles, CA 90095, USA;
| | - Yunsheng Fang
- Department of Bioengineering, University of California, Los Angeles, Los Angeles, CA 90095, USA;
| | - Jun Chen
- Department of Bioengineering, University of California, Los Angeles, Los Angeles, CA 90095, USA;
| |
Collapse
|
39
|
[Applications of microfluidic paper-based chips in environmental analysis and detection]. Se Pu 2021; 39:802-815. [PMID: 34212581 PMCID: PMC9404056 DOI: 10.3724/sp.j.1123.2020.09004] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/25/2022] Open
Abstract
近年来,微流控纸芯片由于低成本、便携化、检测快等优点,在需要快速检测的环境分析领域中展现出了巨大的应用前景。该综述从微流控纸芯片在环境分析中的应用角度,总结归纳了微流控纸芯片在环境分析中的最新研究进展,并展望了其在未来的发展趋势与挑战。论文内容引用150余篇源于科学引文索引(SCI)与中文核心期刊中的相关论文。该综述包括微流控纸芯片在环境检测中的优势与制造方法介绍;电化学法、荧光法、比色法、表面增强拉曼法、集成传感法等基于纸芯片的先进分析方法介绍;根据环境分析目标物种类,如重金属离子、营养盐、农药、微生物、抗生素以及其他污染物等,对纸芯片的最新应用现状进行了举例评述;基于微流控纸芯片的环境分析研究的未来发展趋势和前景展望。通过综述近期相关研究,表明微流控纸芯片从提出至今虽然只有十几年的发展历程,但其在环境分析研究中的发展却十分迅速。微流控纸芯片可以根据不同的环境条件和检测要求灵活选择制作与分析方法,实现最佳的检测效果。但是微流控纸芯片也面临一些挑战,如纸张机械强度不足、流体控制程度不佳等问题。这些问题指出了微流控纸芯片在环境检测领域的发展趋势,相信随着不断深入的研究,纸芯片将会在未来的环境分析中发挥更大作用。
Collapse
|
40
|
Merazzo KJ, Totoricaguena-Gorriño J, Fernández-Martín E, del Campo FJ, Baldrich E. Smartphone-Enabled Personalized Diagnostics: Current Status and Future Prospects. Diagnostics (Basel) 2021; 11:diagnostics11061067. [PMID: 34207908 PMCID: PMC8230325 DOI: 10.3390/diagnostics11061067] [Citation(s) in RCA: 11] [Impact Index Per Article: 2.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/29/2021] [Revised: 06/01/2021] [Accepted: 06/08/2021] [Indexed: 12/18/2022] Open
Abstract
Smartphones are becoming increasingly versatile thanks to the wide variety of sensor and actuator systems packed in them. Mobile devices today go well beyond their original purpose as communication devices, and this enables important new applications, ranging from augmented reality to the Internet of Things. Personalized diagnostics is one of the areas where mobile devices can have the greatest impact. Hitherto, the camera and communication abilities of these devices have been barely exploited for point of care (POC) purposes. This short review covers the recent evolution of mobile devices in the area of POC diagnostics and puts forward some ideas that may facilitate the development of more advanced applications and devices in the area of personalized diagnostics. With this purpose, the potential exploitation of wireless power and actuation of sensors and biosensors using near field communication (NFC), the use of the screen as a light source for actuation and spectroscopic analysis, using the haptic module to enhance mass transport in micro volumes, and the use of magnetic sensors are discussed.
Collapse
Affiliation(s)
- Karla Jaimes Merazzo
- Basque Center for Materials, Applications and Nanostructures, UPV/EHU Science Park, 48940 Leioa, Spain; (K.J.M.); (J.T.-G.); (E.F.-M.)
| | - Joseba Totoricaguena-Gorriño
- Basque Center for Materials, Applications and Nanostructures, UPV/EHU Science Park, 48940 Leioa, Spain; (K.J.M.); (J.T.-G.); (E.F.-M.)
| | - Eduardo Fernández-Martín
- Basque Center for Materials, Applications and Nanostructures, UPV/EHU Science Park, 48940 Leioa, Spain; (K.J.M.); (J.T.-G.); (E.F.-M.)
| | - F. Javier del Campo
- Basque Center for Materials, Applications and Nanostructures, UPV/EHU Science Park, 48940 Leioa, Spain; (K.J.M.); (J.T.-G.); (E.F.-M.)
- IKERBASQUE, Basque Foundation for Science, 48009 Bilbao, Spain
- Correspondence: (F.J.d.C.); (E.B)
| | - Eva Baldrich
- Diagnostic Nanotools Group, CIBBIM-Nanomedicine, Vall d’Hebron Institut de Recerca (VHIR), Vall d’Hebron Barcelona Hospital Campus, 08035 Barcelona, Spain
- Correspondence: (F.J.d.C.); (E.B)
| |
Collapse
|
41
|
Li Z, Xu D, Zhang D, Yamaguchi Y. A portable instrument for on-site detection of heavy metal ions in water. Anal Bioanal Chem 2021; 413:3471-3477. [PMID: 33834269 DOI: 10.1007/s00216-021-03292-w] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Key Words] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/03/2021] [Revised: 03/05/2021] [Accepted: 03/12/2021] [Indexed: 02/01/2023]
Abstract
Based on differential pulse voltammetry technology, we developed a portable and affordable instrument for on-site detection of trace heavy metal pollutants in liquid through a disposable plastic pipette. It mainly consists of a six-electrode electrochemical sensor which is integrated in the instrument. The pipette chip is equipped with a pump valve, and thus, it can avoid contamination. We have analyzed the sensitivity and specificity of the electrochemical sensor for heavy metal detection. Experimental results demonstrated that the limit of detection for Pb, Hg, Cu, and Zn was 2.2 ng/mL, 2.5 ng/mL, 15.5 ng/mL, and 10 ng/mL, respectively. The limit of quantification for them was 10 ng/mL, 25 ng/mL, 25 ng/mL, and 14 ng/mL, respectively. The correlation coefficient between peak current and the target heavy metal concentration was above 0.96. Finally, we have tested the analytical performance of the self-build instrument by measuring heavy metal ions in industrial wastewater and rainwater, respectively. Such an instrument is user-friendly for all users even for the common people, and we can envision its wide application in future heavy metal pollutant detection in groundwater, tap water, and supernatant of soil solution.
Collapse
Affiliation(s)
- Zhenqing Li
- Engineering Research Center of Optical Instrument and System, Key Lab of Optical Instruments and Equipment for Medical Engineering, Ministry of Education, Shanghai Key Lab of Modern Optical System, University of Shanghai for Science and Technology, Shanghai, 200093, China
| | - Debao Xu
- Engineering Research Center of Optical Instrument and System, Key Lab of Optical Instruments and Equipment for Medical Engineering, Ministry of Education, Shanghai Key Lab of Modern Optical System, University of Shanghai for Science and Technology, Shanghai, 200093, China
| | - Dawei Zhang
- Engineering Research Center of Optical Instrument and System, Key Lab of Optical Instruments and Equipment for Medical Engineering, Ministry of Education, Shanghai Key Lab of Modern Optical System, University of Shanghai for Science and Technology, Shanghai, 200093, China.
| | - Yoshinori Yamaguchi
- Engineering Research Center of Optical Instrument and System, Key Lab of Optical Instruments and Equipment for Medical Engineering, Ministry of Education, Shanghai Key Lab of Modern Optical System, University of Shanghai for Science and Technology, Shanghai, 200093, China.
- Oono Joint Research laboratory, Graduate School of Engineering, Osaka University, Osaka, 565-0871, Japan.
- Research and Development, PicoTecBio Corporation, 2-1, Yamada-Oka, Suita-city, Osaka, 565-0871, Japan.
| |
Collapse
|
42
|
Song F, Wang C, Wang C, Gao J, Liu H, Zhang Y, Han L. Enrichment-Detection Integrated Exosome Profiling Biosensors Promising for Early Diagnosis of Cancer. Anal Chem 2021; 93:4697-4706. [DOI: 10.1021/acs.analchem.0c05245] [Citation(s) in RCA: 13] [Impact Index Per Article: 3.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/19/2022]
Affiliation(s)
- Fangteng Song
- Institute of Marine Science and Technology, Shandong University, Qingdao 266237, China
| | - Chao Wang
- Institute of Marine Science and Technology, Shandong University, Qingdao 266237, China
| | - Chunhua Wang
- Institute of Marine Science and Technology, Shandong University, Qingdao 266237, China
| | - Jianwei Gao
- Institute of Marine Science and Technology, Shandong University, Qingdao 266237, China
| | - Hong Liu
- State Key Laboratory of Crystal Materials, Center of Bio & Micro/Nano Functional Materials, Shandong University, Jinan, Shandong 250100, China
| | - Yu Zhang
- Institute of Marine Science and Technology, Shandong University, Qingdao 266237, China
| | - Lin Han
- Institute of Marine Science and Technology, Shandong University, Qingdao 266237, China
| |
Collapse
|
43
|
Das A, Bose S, Mandal N, Pramanick B, RoyChaudhuri C. HOME-Stat: a handheld potentiostat with open-access mobile-interface and extended measurement ranges. PROCEEDINGS OF THE INDIAN NATIONAL SCIENCE ACADEMY 2021. [DOI: 10.1007/s43538-021-00008-7] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/21/2022]
|
44
|
Mukherjee S, Bhattacharyya S, Ghosh K, Pal S, Halder A, Naseri M, Mohammadniaei M, Sarkar S, Ghosh A, Sun Y, Bhattacharyya N. Sensory development for heavy metal detection: A review on translation from conventional analysis to field-portable sensor. Trends Food Sci Technol 2021. [DOI: 10.1016/j.tifs.2021.01.062] [Citation(s) in RCA: 12] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/15/2022]
|
45
|
Costa-Rama E, Fernández-Abedul MT. Paper-Based Screen-Printed Electrodes: A New Generation of Low-Cost Electroanalytical Platforms. BIOSENSORS 2021; 11:51. [PMID: 33669316 PMCID: PMC7920281 DOI: 10.3390/bios11020051] [Citation(s) in RCA: 37] [Impact Index Per Article: 9.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 12/16/2020] [Revised: 01/20/2021] [Accepted: 02/01/2021] [Indexed: 12/15/2022]
Abstract
Screen-printed technology has helped considerably to the development of portable electrochemical sensors since it provides miniaturized but robust and user-friendly electrodes. Moreover, this technology allows to obtain very versatile transducers, not only regarding their design, but also their ease of modification. Therefore, in the last decades, the use of screen-printed electrodes (SPEs) has exponentially increased, with ceramic as the main substrate. However, with the growing interest in the use of cheap and widely available materials as the basis of analytical devices, paper or other low-cost flat materials have become common substrates for SPEs. Thus, in this revision, a comprehensive overview on paper-based SPEs used for analytical proposes is provided. A great variety of designs is reported, together with several examples to illustrate the main applications.
Collapse
|
46
|
Smartphone-Based NFC Potentiostat for Wireless Electrochemical Sensing. APPLIED SCIENCES-BASEL 2021. [DOI: 10.3390/app11010392] [Citation(s) in RCA: 20] [Impact Index Per Article: 5.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 12/19/2022]
Abstract
Most electrochemical sensing requires affordable, portable and easy-to-use electrochemical devices for use in point-of-care testing and resource-limited settings. This work presents the design and evaluates the analytical performance of a near-field communication (NFC) potentiostat, a flat card-sized electrochemical device containing a microchip for electrical analysis and an NFC antenna for smartphone connection. The NFC interface is a wireless connection between the microchip and smartphone to simplify measuring units and make the potentiostat into a passive operated device, running without a battery. The proposed potentiostat can perform the common electrochemical techniques including cyclic voltammetry and chronoamperometry with a current range and voltage range of ±20 µA and ±0.8 V. The performance of the NFC potentiostat is compared to a commercial benchtop potentiostat using ferricyanide as a standard solution. The results show that the NFC potentiostat is comparable to a commercial benchtop potentiostat for both cyclic voltammetry and chronoamperometry measurements. The application of the proposed potentiostat is demonstrated by measuring ascorbic acid concentration. As described, the NFC potentiostat, which is compatible with a smartphone, is low-cost, small in size and user-friendly. Thus, the device can be developed for on-site measurement to apply in various fields.
Collapse
|
47
|
Abstract
The consumption of reactive dyes in the batik industry has led to a severe concern in monitoring the heavy metal level in wastewater. Due to the necessity of implementing a wastewater monitoring system in the batik factory, a Heavy Metal potentiostat (HMstat) was designed. The main goal of this study is to understand the optimal design concept of the potentiostat function in order to investigate the losses of accuracy in measurement using off-the-shelf devices. Through lab-scale design, the HMstat comprises of an analog potentiostat read-out circuit component (PRCC) and a digital control signal component (CSC). The PRCC is based on easy to use components integrated with a NI-myRIO controller in a CSC. Here, the myRIO was equipped with built-in analog to digital converter (ADC) and digital to analog converter (DAC) components. In this paper, the accuracy test and detection of cadmium(II) (Cd2+) and lead(II) (Pb2+) were conducted using the HMstat. The results were compared with the Rodeostat (an open source potentiostat available on the online market). The accuracy of the HMStat was higher than 95% and within the precision rate of the components used. The HMstat was able to detect Cd2+ and Pb2+ at −0.25 and −0.3 V, respectively. Similar potential peaks were obtained using Rodeostat (Cd2+ at −0.25 V and Pb2+ at −0.3 V).
Collapse
|
48
|
Chen W, Yao Y, Chen T, Shen W, Tang S, Lee HK. Application of smartphone-based spectroscopy to biosample analysis: A review. Biosens Bioelectron 2020; 172:112788. [PMID: 33157407 DOI: 10.1016/j.bios.2020.112788] [Citation(s) in RCA: 53] [Impact Index Per Article: 10.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/21/2020] [Revised: 10/05/2020] [Accepted: 10/30/2020] [Indexed: 12/18/2022]
Abstract
The emergence of the smartphones has brought extensive changes to our lifestyles, from communicating with one another, to shopping and enjoyment of entertainment, and from studying to functioning at the workplace (and in the field). At the same time, this portable device has also provided new possibilities in scientific research and applications. Based on the growing awareness of good health management, researchers have coupled health monitoring to smartphone sensing technologies. Along the way, there have been developed a variety of smartphone-based optical detection platforms for analyzing biological samples, including standalone smartphone units and integrated smartphone sensing systems. In this review, we outline the applications of smartphone-based optical sensors for biosamples. These applications focus mainly on three aspects: Microscopic imaging sensing, colorimetric sensing and luminescence sensing. We also discuss briefly some limitations of the current state of smartphone-based spectroscopy and present prospects of the future applicability of smartphone sensors.
Collapse
Affiliation(s)
- Wenhui Chen
- School of Environmental and Chemical Engineering, Jiangsu University of Science and Technology, Zhenjiang, 212003, Jiangsu Province, China
| | - Yao Yao
- School of Environmental and Chemical Engineering, Jiangsu University of Science and Technology, Zhenjiang, 212003, Jiangsu Province, China
| | - Tianyu Chen
- School of Environmental and Chemical Engineering, Jiangsu University of Science and Technology, Zhenjiang, 212003, Jiangsu Province, China
| | - Wei Shen
- School of Environmental and Chemical Engineering, Jiangsu University of Science and Technology, Zhenjiang, 212003, Jiangsu Province, China
| | - Sheng Tang
- School of Environmental and Chemical Engineering, Jiangsu University of Science and Technology, Zhenjiang, 212003, Jiangsu Province, China.
| | - Hian Kee Lee
- Department of Chemistry, National University of Singapore, 3 Science Drive 3, Singapore, 117543, Singapore; National University of Singapore Environmental Research Institute, T-Lab Building #02-01, 5A Engineering Drive 1, Singapore, 117411, Singapore; Tropical Marine Science Institute, National University of Singapore, S2S Building, 18 Kent Ridge Road, Singapore, 119227, Singapore.
| |
Collapse
|
49
|
Teymourian H, Barfidokht A, Wang J. Electrochemical glucose sensors in diabetes management: an updated review (2010-2020). Chem Soc Rev 2020; 49:7671-7709. [PMID: 33020790 DOI: 10.1039/d0cs00304b] [Citation(s) in RCA: 349] [Impact Index Per Article: 69.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/12/2022]
Abstract
While over half a century has passed since the introduction of enzyme glucose biosensors by Clark and Lyons, this important field has continued to be the focus of immense research activity. Extensive efforts during the past decade have led to major scientific and technological innovations towards tight monitoring of diabetes. Such continued progress toward advanced continuous glucose monitoring platforms, either minimal- or non-invasive, holds considerable promise for addressing the limitations of finger-prick blood testing toward tracking glucose trends over time, optimal therapeutic interventions, and improving the life of diabetes patients. However, despite these major developments, the field of glucose biosensors is still facing major challenges. The scope of this review is to present the key scientific and technological advances in electrochemical glucose biosensing over the past decade (2010-present), along with current obstacles and prospects towards the ultimate goal of highly stable and reliable real-time minimally-invasive or non-invasive glucose monitoring. After an introduction to electrochemical glucose biosensors, we highlight recent progress based on using advanced nanomaterials at the electrode-enzyme interface of three generations of glucose sensors. Subsequently, we cover recent activity and challenges towards next-generation wearable non-invasive glucose monitoring devices based on innovative sensing principles, alternative body fluids, advanced flexible materials, and novel platforms. This is followed by highlighting the latest progress in the field of minimally-invasive continuous glucose monitoring (CGM) which offers real-time information about interstitial glucose levels, by focusing on the challenges toward developing biocompatible membrane coatings to protect electrochemical glucose sensors against surface biofouling. Subsequent sections cover new analytical concepts of self-powered glucose sensors, paper-based glucose sensing and multiplexed detection of diabetes-related biomarkers. Finally, we will cover the latest advances in commercially available devices along with the upcoming future technologies.
Collapse
Affiliation(s)
- Hazhir Teymourian
- Department of NanoEngineering, University of California San Diego, La Jolla, CA 92093, USA.
| | | | | |
Collapse
|
50
|
Dadkhah S, Mehdinia A, Jabbari A, Manbohi A. Rapid and sensitive fluorescence and smartphone dual-mode detection of dopamine based on nitrogen-boron co-doped carbon quantum dots. Mikrochim Acta 2020; 187:569. [DOI: 10.1007/s00604-020-04543-w] [Citation(s) in RCA: 15] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/28/2019] [Accepted: 09/02/2020] [Indexed: 12/31/2022]
|