1
|
Opportunities involving microfluidics and 3D culture systems to the in vitro embryo production. Anim Reprod 2023; 20:e20230058. [PMID: 37638255 PMCID: PMC10449241 DOI: 10.1590/1984-3143-ar2023-0058] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/26/2022] [Accepted: 06/29/2023] [Indexed: 08/29/2023] Open
Abstract
Traditional methods of gamete handling, fertilization, and embryo culture often face limitations in efficiency, consistency, and the ability to closely mimic in vivo conditions. This review explores the opportunities presented by microfluidic and 3D culture systems in overcoming these challenges and enhancing in vitro embryo production. We discuss the basic principles of microfluidics, emphasizing their inherent advantages such as precise control of fluid flow, reduced reagent consumption, and high-throughput capabilities. Furthermore, we delve into microfluidic devices designed for gamete manipulation, in vitro fertilization, and embryo culture, highlighting innovations such as droplet-based microfluidics and on-chip monitoring. Next, we explore the integration of 3D culture systems, including the use of biomimetic scaffolds and organ-on-a-chip platforms, with a particular focus on the oviduct-on-a-chip. Finally, we discuss the potential of these advanced systems to improve embryo production outcomes and advance our understanding of early embryo development. By leveraging the unique capabilities of microfluidics and 3D culture systems, we foresee significant advancements in the efficiency, effectiveness, and clinical success of in vitro embryo production.
Collapse
|
2
|
MIP-on-a-chip: Artificial receptors on microfluidic platforms for biomedical applications. J Pharm Biomed Anal 2023; 226:115257. [PMID: 36669397 DOI: 10.1016/j.jpba.2023.115257] [Citation(s) in RCA: 7] [Impact Index Per Article: 7.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/25/2022] [Revised: 01/03/2023] [Accepted: 01/16/2023] [Indexed: 01/19/2023]
Abstract
Lab-on-a-chip (LOC) as an alternative biosensing approach concerning cost efficiency, parallelization, ergonomics, diagnostic speed, and sensitivity integrates the techniques of various laboratory operations such as biochemical analysis, chemical synthesis, or DNA sequencing, etc. on miniaturized microfluidic single chips. Meanwhile, LOC tools based on molecularly imprinted biosensing approach permit their applications in various fields such as medical diagnostics, pharmaceuticals, etc., which are user-, and eco-friendly sensing platforms for not only alternative to the commercial competitor but also on-site detection like point-of-care measurements. In this review, we focused our attention on compiling recent pioneer studies that utilized those intriguing methodologies, the microfluidic Lab-on-a-chip and molecularly imprinting approach, and their biomedical applications.
Collapse
|
3
|
Bio-actuated microvalve in microfluidics using sensing and actuating function of Mimosa pudica. Sci Rep 2022; 12:7653. [PMID: 35606389 PMCID: PMC9126872 DOI: 10.1038/s41598-022-11637-3] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/13/2022] [Accepted: 04/26/2022] [Indexed: 11/25/2022] Open
Abstract
Bio-actuators and sensors are increasingly employed in microscale devices for numerous applications. Unlike other artificial devices actuated by living cells or tissues, here we introduce a microvalve system actuated by the stimuli-responsive action plant, Mimosa pudica (sleepy plant). This system realizes the control of the valve to open and close by dropping and recovering responses of Mimosa pudica branch upon external physical stimulations. The results showed that one matured single uncut Mimosa pudica branch produced average force of 15.82 ± 0.7 mN. This force was sufficient for actuating and keeping the valve open for 8.46 ± 1.33 min in a stimulation-recovering cycle of 30 min. Additionally, two separately cut Mimosa pudica branches were able to keep the valve open for 2.28 ± 0.63 min in a stimulating-recovering cycle of 20min. The pressure resistance and the response time of the valve were 4.2 kPa and 1.4 s, respectively. This demonstration of plant-microfluidics integration encourages exploiting more applications of microfluidic platforms that involve plant science and plant energy harvesting.
Collapse
|
4
|
Reversible Crosslinking of Polymer/Metal-Ion Complexes for a Microfluidic Switch. ACS OMEGA 2021; 6:35297-35306. [PMID: 34984261 PMCID: PMC8717383 DOI: 10.1021/acsomega.1c04055] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 07/29/2021] [Accepted: 12/03/2021] [Indexed: 05/30/2023]
Abstract
The importance of chitosan has been strongly emphasized in literature because this natural polymer could not only remove heavy metal ions in water but also have the potential for recyclability. However, reversible phase transition and its dynamics, which are highlighting areas of a recycle process, have not been studied sufficiently. Here, we present dynamic studies of the dissolution as well as the gelation of a physically crosslinked chitosan hydrogel. Specifically, a one-dimensional gel growth system and an acetate buffer solution were prepared for the precise analysis of the dominant factors affecting a phase transition. The dissolution rate was found to be regulated by three major factors of the pH level, Cu2+, and NO2 -, while the gelation rate was strongly governed by the concentration of OH-. Apart from the gelation rate, the use of Cu2+ led to the rapid realization of gel characteristics. The results here provide strategies for process engineering, ultimately to determine the phase-transition rates. In addition, a microfluidic switch was successfully operated based on a better understanding of the reversible crosslinking of the chitosan hydrogel. Rapid gelation was required to close the channel, and a quick switchover was achieved by a dissolution enhancement strategy. As a result, factors that regulated the rates of gelation or dissolution were found to be useful to operate the fluidic switch.
Collapse
|
5
|
Abstract
Lab-on-a-chip devices leverage microfluidic technologies to enable chemical and biological processes at small scales. However, existing microfluidic channel networks are typically designed for the implementation of a single function or a well-defined protocol and do not allow the flexibility and real-time experimental decision-making essential to many scientific applications. In this Perspective, we highlight that reconfigurability and programmability of microfluidic platforms can support new functionalities that are beyond the reach of current lab-on-a-chip systems. We describe the ideal fully reconfigurable microfluidic device that can change its shape and function dynamically, which would allow researchers to tune a microscale experiment with the capacity to make real-time decisions. We review existing technologies that can dynamically control microscale flows, suggest additional physical mechanisms that could be leveraged towards the goal of reconfigurable microfluidics and highlight the importance of these efforts for the broad scientific community.
Collapse
|
6
|
Design and construction of three-dimensional physiologically-based vascular branching networks for respiratory assist devices. LAB ON A CHIP 2021; 21:4637-4651. [PMID: 34730597 DOI: 10.1039/d1lc00287b] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/13/2023]
Abstract
Microfluidic lab-on-a-chip devices are changing the way that in vitro diagnostics and drug development are conducted, based on the increased precision, miniaturization and efficiency of these systems relative to prior methods. However, the full potential of microfluidics as a platform for therapeutic medical devices such as extracorporeal organ support has not been realized, in part due to limitations in the ability to scale current designs and fabrication techniques toward clinically relevant rates of blood flow. Here we report on a method for designing and fabricating microfluidic devices supporting blood flow rates per layer greater than 10 mL min-1 for respiratory support applications, leveraging advances in precision machining to generate fully three-dimensional physiologically-based branching microchannel networks. The ability of precision machining to create molds with rounded features and smoothly varying channel widths and depths distinguishes the geometry of the microchannel networks described here from all previous reports of microfluidic respiratory assist devices, regarding the ability to mimic vascular blood flow patterns. These devices have been assembled and tested in the laboratory using whole bovine or porcine blood, and in a porcine model to demonstrate efficient gas transfer, blood flow and pressure stability over periods of several hours. This new approach to fabricating and scaling microfluidic devices has the potential to address wide applications in critical care for end-stage organ failure and acute illnesses stemming from respiratory viral infections, traumatic injuries and sepsis.
Collapse
|
7
|
Implantable Microfluidic Device: An Epoch of Technology. Curr Pharm Des 2021; 28:679-689. [PMID: 34525928 DOI: 10.2174/1381612827666210825114403] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/02/2020] [Accepted: 05/28/2021] [Indexed: 11/22/2022]
Abstract
Implantable microfluidic devices are milestones in developing devices that can either measure parameters like ocular pressure and blood glucose level or deliver various components for therapeutic needs or behavioral modification. Researchers are currently focusing on the miniaturization of almost all its tools for a better healthcare platform. Implantable microfluidic devices are a combination of various systems including, but not limited to, microfluidic platforms, reservoirs, sensors, and actuators, implanted inside the body of a living entity (in vivo) with the purpose of directly or indirectly helping the entity. It is a multidisciplinary approach with immense potential in the area of the biomedical field. Significant resources are utilizing on for the research and development of these devices for various applications. The induction of an implantable microfluidic device into an animal would enable us to measure the responses without any repeated invasive procedures. Such data would help in the development of a better drug delivery profile. Implantable microfluidic devices with reservoirs deliver specific chemical or biological products to treat situations like cancers and diabetes. They can also deliver fluorophores for specific imaging inside the body. Implantable microfluidic devices help provide a microenvironment for various cell differentiation procedure. These devices know no boundaries, and this article reviews these devices based on their design and applications.
Collapse
|
8
|
|
9
|
Microchip for continuous DNA analysis based on gel electrophoresis coupled with co-injection of size markers and in-channel staining. Anal Bioanal Chem 2021; 413:5685-5694. [PMID: 34345950 DOI: 10.1007/s00216-021-03560-9] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/29/2021] [Revised: 07/05/2021] [Accepted: 07/16/2021] [Indexed: 10/20/2022]
Abstract
A continuous-flow microchip enabling high-accuracy DNA analysis was developed. Serial consecutive analysis for multiple amplified DNA samples was demonstrated. The sample segments were continuously introduced to the microchip from the PCR device which was interfaced to the microchip through capillary tubing. Electrokinetic co-injection of the DNA samples with size marker enabled reproducible and reliable injection of the DNAs into the gel-filled separation channel providing accurate size determination of the DNA samples. Cross-contamination between serially introduced DNA samples was minimized by plugging a washing solution segment following the previous sample segment between two sample plugs. Using this microchip, continuous separation of multiple samples was performed without any inconvenient and labor-intensive sample preparation steps such as sample mixing, staining, and gel loading which are necessary for conventional gel electrophoresis. It has taken about 4 min to separate single DNA sample and taken 37 min for three serially injected samples which implies that this microchip can be a platform device for fast as well as highly accurate DNA analysis.
Collapse
|
10
|
Microsized 3D Hydrogel Printing System using Microfluidic Maskless Lithography and Single Axis Stepper Motor. BIOCHIP JOURNAL 2020. [DOI: 10.1007/s13206-020-4310-4] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 12/28/2022]
|
11
|
Modeling Immune Checkpoint Inhibitor Efficacy in Syngeneic Mouse Tumors in an Ex Vivo Immuno-Oncology Dynamic Environment. Int J Mol Sci 2020; 21:ijms21186478. [PMID: 32899865 PMCID: PMC7555450 DOI: 10.3390/ijms21186478] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/13/2020] [Revised: 08/20/2020] [Accepted: 08/26/2020] [Indexed: 12/22/2022] Open
Abstract
The immune checkpoint blockade represents a revolution in cancer therapy, with the potential to increase survival for many patients for whom current treatments are not effective. However, response rates to current immune checkpoint inhibitors vary widely between patients and different types of cancer, and the mechanisms underlying these varied responses are poorly understood. Insights into the antitumor activities of checkpoint inhibitors are often obtained using syngeneic mouse models, which provide an in vivo preclinical basis for predicting efficacy in human clinical trials. Efforts to establish in vitro syngeneic mouse equivalents, which could increase throughput and permit real-time evaluation of lymphocyte infiltration and tumor killing, have been hampered by difficulties in recapitulating the tumor microenvironment in laboratory systems. Here, we describe a multiplex in vitro system that overcomes many of the deficiencies seen in current static histocultures, which we applied to the evaluation of checkpoint blockade in tumors derived from syngeneic mouse models. Our system enables both precision-controlled perfusion across biopsied tumor fragments and the introduction of checkpoint-inhibited tumor-infiltrating lymphocytes in a single experiment. Through real-time high-resolution confocal imaging and analytics, we demonstrated excellent correlations between in vivo syngeneic mouse and in vitro tumor biopsy responses to checkpoint inhibitors, suggesting the use of this platform for higher throughput evaluation of checkpoint efficacy as a tool for drug development.
Collapse
|
12
|
Microfluidic-RT-LAMP chip for the point-of-care detection of emerging and re-emerging enteric coronaviruses in swine. Anal Chim Acta 2020; 1125:57-65. [PMID: 32674781 PMCID: PMC7234951 DOI: 10.1016/j.aca.2020.05.034] [Citation(s) in RCA: 23] [Impact Index Per Article: 5.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/24/2020] [Revised: 05/12/2020] [Accepted: 05/13/2020] [Indexed: 12/14/2022]
Abstract
Porcine epidemic diarrhea virus (PEDV), porcine deltacoronavirus (PDCoV), and swine acute diarrhea syndrome-coronavirus (SADS-CoV) are three emerging and re-emerging coronaviruses (CoVs). Symptoms caused by these three viruses are extremely similar, including acute diarrhea, vomiting and even death in piglets. To date, strict biosecurity is still the most effective disease prevention and control measures, and the early detection of pathogens is the most important link. Here, we developed a microfluidic-RT-LAMP chip detection system for the first time, which could detected PEDV, PDCoV and SADS-CoV simultaneously, and had advantages of rapid, simple, sensitive, high-throughput, and accurate at point-of-care settings. The lowest detection limits of the microfluidic-RT-LAMP chip method are 101 copies/μL, 102 copies/μL and 102 copies/μL for PEDV, PDCoV and SADS-CoV, respectively. The whole detection procedure can be finished rapidly in 40 min without any cross-reaction with other common swine viruses. A total of 173 clinical swine fecal samples characterized with diarrheal symptoms were used to evaluate the performance of the newly developed system, which presented good stabilities (C.V.s<5%) and specificities (100%), and possessed sensitivities of 92.24%, 92.19% and 91.23% for PEDV, PDCoV and SADS-CoV respectively. In summary, the established microfluidic-RT-LAMP chip detection system could satisfy the demanding in field diagnoses, which was suitable for promotion in remote areas due to its fast, portable and cost-effective characters.
Collapse
|
13
|
|
14
|
Rapid photothermal actuation of light-addressable, arrayed hydrogel columns in a macroporous silicon membrane. SENSORS AND ACTUATORS. A, PHYSICAL 2020; 301:111729. [PMID: 32863582 PMCID: PMC7451047 DOI: 10.1016/j.sna.2019.111729] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/11/2023]
Abstract
This paper presents rapid photothermal actuation of light-addressable, arrayed hydrogel columns in a macroporous silicon membrane. Au nanorods are incorporated into thermo-responsive p-NIPAAm hydrogel to utilize surface plasmon-induced local heating by near-infrared light. By measuring optical transmission through the fabricated membrane structure with Au nanorod embedded hydrogel, we have demonstrated that photothermal actuation of hydrogel can be done in two-dimensional, pixel-like configuration with high spatial and temporal resolutions. Benefiting from the hydrogel volume confinement within micron-sized pores, we have achieved sub-second response time of hydrogel photothermal actuation and its repeatable photothermal actuation on highly localized illuminated area. Considering that each hydrogel column is confined within each pore and different wavelength of light can be used to induce photothermal actuation of hydrogel's deswelling characteristics by modifying physical dimensions of Au nanorods, it has a potential for optically-addressable, multiplexed drug release systems with rapid response time.
Collapse
|
15
|
|
16
|
A valve powered by earthworm muscle with both electrical and 100% chemical control. Sci Rep 2019; 9:8042. [PMID: 31285453 PMCID: PMC6614428 DOI: 10.1038/s41598-019-44116-3] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/04/2018] [Accepted: 05/07/2019] [Indexed: 01/09/2023] Open
Abstract
Development of bio-microactuators combining microdevices and cellular mechanical functions has been an active research field owing to their desirable properties including high mechanical integrity and biocompatibility. Although various types of devices were reported, the use of as-is natural muscle tissue should be more effective. An earthworm muscle-driven valve has been created. Long-time (more than 2 min) and repeatable displacement was observed by chemical (acetylcholine) stimulation. The generated force of the muscle (1 cm × 3 cm) was 1.57 mN on average for 2 min by the acetylcholine solution (100 mM) stimulation. We demonstrated an on-chip valve that stopped the constant pressure flow by the muscle contraction. For electrical control, short pulse stimulation was used for the continuous and repeatable muscle contraction. The response time was 3 s, and the pressure resistance was 3.0 kPa. Chemical stimulation was then used for continuous muscle contraction. The response time was 42 s, and the pressure resistance was 1.5 kPa. The ON (closed) state was kept for at least 2 min. An on-chip valve was demonstrated that stopped the constant pressure flow by the muscle contraction. This is the first demonstration of the muscle-based valve that is 100% chemically actuated and controlled.
Collapse
|
17
|
Nanobuffering of pH-Responsive Polymers: A Known but Sometimes Overlooked Phenomenon and Its Biological Applications. ACS NANO 2019; 13:4876-4882. [PMID: 30985108 PMCID: PMC6748625 DOI: 10.1021/acsnano.9b01696] [Citation(s) in RCA: 56] [Impact Index Per Article: 11.2] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/02/2023]
Abstract
With recent advances in polymer chemistry, materials science, and nanotechnology, pH-responsive polymers have a significant impact in a number of diverse fields. Fundamental studies of these polymers are thus highly desirable as they may lead to new insights into the rational design of pH-responsive polymers with specific effects. In this Perspective, we focus on the nanobuffering of pH-responsive polymers (NBPRP). Although researchers have known of such buffering effects for more than a century, for example, in the context of the Henderson-Hasselbalch equation, modern synthesis and analysis routes now enable us to analyze these effects on the nanometer scale. In this way, the NBPRP phenomenon was explicitly defined and described by Gauthier and colleagues in the February issue of ACS Nano. Here, we highlight several potential areas in which the NBPRP could enable innovative classes of biological applications. We expect deeper mechanistic understanding of nanobuffering effects induced by pH-responsive polymers to have a significant impact on the future development and applications of these polymers.
Collapse
|
18
|
Assessing the Reusability of 3D-Printed Photopolymer Microfluidic Chips for Urine Processing. MICROMACHINES 2018; 9:E520. [PMID: 30424453 PMCID: PMC6215198 DOI: 10.3390/mi9100520] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 09/26/2018] [Revised: 10/11/2018] [Accepted: 10/14/2018] [Indexed: 11/25/2022]
Abstract
Three-dimensional (3D) printing is emerging as a method for microfluidic device fabrication boasting facile and low-cost fabrication, as compared to conventional fabrication approaches, such as photolithography, for poly(dimethylsiloxane) (PDMS) counterparts. Additionally, there is an increasing trend in the development and implementation of miniaturized and automatized devices for health monitoring. While nonspecific protein adsorption by PDMS has been studied as a limitation for reusability, the protein adsorption characteristics of 3D-printed materials have not been well-studied or characterized. With these rationales in mind, we study the reusability of 3D-printed microfluidics chips. Herein, a 3D-printed cleaning chip, consisting of inlets for the sample, cleaning solution, and air, and a universal outlet, is presented to assess the reusability of a 3D-printed microfluidic device. Bovine serum albumin (BSA) was used a representative urinary protein and phosphate-buffered solution (PBS) was chosen as the cleaning agent. Using the 3-(4-carboxybenzoyl)quinoline-2-carboxaldehyde (CBQCA) fluorescence detection method, the protein cross-contamination between samples and the protein uptake of the cleaning chip were assessed, demonstrating a feasible 3D-printed chip design and cleaning procedure to enable reusable microfluidic devices. The performance of the 3D-printed cleaning chip for real urine sample handling was then validated using a commercial dipstick assay.
Collapse
|
19
|
Point-of-care microfluidic devices for pathogen detection. Biosens Bioelectron 2018; 117:112-128. [PMID: 29890393 PMCID: PMC6082696 DOI: 10.1016/j.bios.2018.05.050] [Citation(s) in RCA: 213] [Impact Index Per Article: 35.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/14/2018] [Revised: 05/22/2018] [Accepted: 05/28/2018] [Indexed: 12/22/2022]
Abstract
The rapid diagnosis of pathogens is crucial in the early stages of treatment of diseases where the choice of the correct drug can be critical. Although conventional cell culture-based techniques have been widely utilized in clinical applications, newly introduced optical-based, microfluidic chips are becoming attractive. The advantages of the novel methods compared to the conventional techniques comprise more rapid diagnosis, lower consumption of patient sample and valuable reagents, easy application, and high reproducibility in the detection of pathogens. The miniaturized channels used in microfluidic systems simulate interactions between cells and reagents in microchannel structures, and evaluate the interactions between biological moieties to enable diagnosis of microorganisms. The overarching goal of this review is to provide a summary of the development of microfluidic biochips and to comprehensively discuss different applications of microfluidic biochips in the detection of pathogens. New types of microfluidic systems and novel techniques for viral pathogen detection (e.g. HIV, HVB, ZIKV) are covered. Next generation techniques relying on high sensitivity, specificity, lower consumption of precious reagents, suggest that rapid generation of results can be achieved via optical based detection of bacterial cells. The introduction of smartphones to replace microscope based observation has substantially improved cell detection, and allows facile data processing and transfer for presentation purposes.
Collapse
|
20
|
Fabrication of a Malaria-Ab ELISA Bioassay Platform with Utilization of Syringe-Based and 3D Printed Assay Automation. MICROMACHINES 2018; 9:E502. [PMID: 30424435 PMCID: PMC6215250 DOI: 10.3390/mi9100502] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 08/30/2018] [Revised: 09/26/2018] [Accepted: 09/30/2018] [Indexed: 12/15/2022]
Abstract
We report on the fabrication of a syringe-based platform for automation of a colorimetric malaria-Ab assay. We assembled this platform from inexpensive disposable plastic syringes, plastic tubing, easily-obtainable servomotors, and an Arduino microcontroller chip, which allowed for system automation. The automated system can also be fabricated using stereolithography (SLA) to print elastomeric reservoirs (used instead of syringes), while platform framework, including rack and gears, can be printed with fused deposition modeling (FDM). We report on the optimization of FDM and SLA print parameters, as well as post-production processes. A malaria-Ab colorimetric test was successfully run on the automated platform, with most of the assay reagents dispensed from syringes. Wash solution was dispensed from an SLA-printed elastomeric reservoir to demonstrate the feasibility of both syringe and elastomeric reservoir-based approaches. We tested the platform using a commercially available malaria-Ab colorimetric assay originally designed for spectroscopic plate readers. Unaided visual inspection of the assay solution color change was sufficient for qualitative detection of positive and negative samples. A smart phone application can also be used for quantitative measurement of the assay color change.
Collapse
|
21
|
|
22
|
A multiplexed microfluidic system for evaluation of dynamics of immune-tumor interactions. LAB ON A CHIP 2018; 18:1844-1858. [PMID: 29796561 DOI: 10.1039/c8lc00256h] [Citation(s) in RCA: 66] [Impact Index Per Article: 11.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/12/2023]
Abstract
Recapitulation of the tumor microenvironment is critical for probing mechanisms involved in cancer, and for evaluating the tumor-killing potential of chemotherapeutic agents, targeted therapies and immunotherapies. Microfluidic devices have emerged as valuable tools for both mechanistic studies and for preclinical evaluation of therapeutic agents, due to their ability to precisely control drug concentrations and gradients of oxygen and other species in a scalable and potentially high throughput manner. Most existing in vitro microfluidic cancer models are comprised of cultured cancer cells embedded in a physiologically relevant matrix, collocated with vascular-like structures. However, the recent emergence of immune checkpoint inhibitors (ICI) as a powerful therapeutic modality against many cancers has created a need for preclinical in vitro models that accommodate interactions between tumors and immune cells, particularly for assessment of unprocessed tumor fragments harvested directly from patient biopsies. Here we report on a microfluidic model, termed EVIDENT (ex vivo immuno-oncology dynamic environment for tumor biopsies), that accommodates up to 12 separate tumor biopsy fragments interacting with flowing tumor-infiltrating lymphocytes (TILs) in a dynamic microenvironment. Flow control is achieved with a single pump in a simple and scalable configuration, and the entire system is constructed using low-sorption materials, addressing two principal concerns with existing microfluidic cancer models. The system sustains tumor fragments for multiple days, and permits real-time, high-resolution imaging of the interaction between autologous TILs and tumor fragments, enabling mapping of TIL-mediated tumor killing and testing of various ICI treatments versus tumor response. Custom image analytic algorithms based on machine learning reported here provide automated and quantitative assessment of experimental results. Initial studies indicate that the system is capable of quantifying temporal levels of TIL infiltration and tumor death, and that the EVIDENT model mimics the known in vivo tumor response to anti-PD-1 ICI treatment of flowing TILs relative to isotype control treatments for syngeneic mouse MC38 tumors.
Collapse
|
23
|
Switchable Underwater Bubble Wettability on Laser-Induced Titanium Multiscale Micro-/Nanostructures by Vertically Crossed Scanning. ACS APPLIED MATERIALS & INTERFACES 2018; 10:16867-16873. [PMID: 29694017 DOI: 10.1021/acsami.8b02812] [Citation(s) in RCA: 12] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/08/2023]
Abstract
We present here a kind of novel multiscale TiO2 square micropillar arrays on titanium sheets through vertically crossed scanning of femtosecond laser. This multiscale micro-/nanostructure is ascribed to the combination of laser ablation/shock compression/debris self-deposition, which shows superaerophobicity in water with a very small sliding angle. The laser-induced sample displays switchable bubble wettability in water via heating in a dark environment and ultraviolet (UV) irradiation in alcohol. After heating in a dark environment (0.5 h), the ablated titanium surface shows superaerophilicity in water with a bubble contact angle (BCA) of ∼4°, which has a great ability of capturing bubbles in water. After UV irradiation in alcohol (1 h), the sample recovered its superaerophobicity in water and the BCA turns into 156°. The mechanism of reversible switching is believed as the chemical conversion between Ti-OH and Ti-O. It is worth noting that our proposed switching strategy is time-saving and the switch wetting cycle costs only 1.5 h. Then we repeat five switching cycles on the reversibility and the method shows excellent reproducibility and stability. Moreover, laser-induced samples with different scanning spacing (50-120 μm) are fabricated and all of them show switchable underwater bubble wettability via the above tunable methods. Finally, we fabricate hybrid-patterned microstructures to show different patterned bubbles in water on the heated samples. We believe the original works will provide some new insights to researchers in bubble manipulation and gas collection fields.
Collapse
|
24
|
Integrated dual-modality microfluidic sensor for biomarker detection using lithographic plasmonic crystal. LAB ON A CHIP 2018; 18:803-817. [PMID: 29431801 DOI: 10.1039/c7lc01211j] [Citation(s) in RCA: 10] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/08/2023]
Abstract
This paper reports an integrated dual-modality microfluidic sensor chip, consisting of a patterned periodic array of nanoposts coated with gold (Au) and graphene oxide (GO), to detect target biomarker molecules in a limited sample volume. The device generates both electrochemical and surface plasmon resonance (SPR) signals from a single sensing area of Au-GO nanoposts. The Au-GO nanoposts are functionalized with specific receptor molecules, serving as a spatially well-defined nanostructured working electrode for electrochemical sensing, as well as a nanostructured plasmonic crystal for SPR-based sensing via the excitation of surface plasmon polaritons. High sensitivity of the electrochemical measurement originates from the presence of the nanoposts on the surface of the working electrode where radial diffusion of redox species occurs. Complementarily, the SPR detection allows convenient tracking of dynamic antigen-antibody interactions, to describe the association and dissociation phases occurring at the sensor surface. The soft-lithographically formed nanoposts provide high reproducibility of the sensor response to epidermal growth factor receptor (ErbB2) molecules even at a femtomolar level. Sensitivities of the electrochemical measurements to ErbB2 are found to be 20.47 μA μM-1 cm-2 in a range from 1 fM to 0.1 μM, and those of the SPR measurements to be 1.35 nm μM-1 in a range from 10 pM to 1 nM, and 0.80 nm μM-1 in a range from 1 nM to 0.1 μM. The integrated dual-modality sensor offers higher sensitivity (through higher surface area and diffusions from nanoposts for electrochemical measurements), as well as the dynamic measurements of antigen-antibody bindings (through the SPR measurement), while operating simultaneously in a same sensing area using the same sample volume.
Collapse
|
25
|
Abstract
Optical absorbance detection based on attenuated light transmission is limited in sensitivity due to short path lengths in microfluidic and other miniaturized platforms. An alternative is detection using the photothermal effect. Herein we introduce a new kind of photothermal absorbance measurement using integrated luminescent temperature sensor spots inside microfluidic channels. The temperature sensors were photopolymerized inside the channels from NOA 81 UV-curable thiolene prepolymer doped with a tris(1,10-phenanthroline)ruthenium(II) temperature probe. The polymerized sensing structures were as small as 26 ± 3 μm in diameter and displayed a temperature resolution of better than 0.3 K between 20 and 50 °C. The absorbance from 532 nm laser excitation of the food dye Amaranth as a model analyte was quantified using these spots, and the influence of the flow rate, laser power, and concentration was investigated. Calibration yielded a linear relationship between analyte concentration and the temperature signal in the channels. The limit of detection for the azo-dye Amaranth (E123) in this setup was 13 μM. A minimal detectable absorbance of 3.2 × 10-3 AU was obtained using an optical path length of 125 μm in this initial study. A microreactor with integrated temperature sensors was then employed for an absorbance-based miniaturized nitrite analysis, yielding a detection limit of 26 μM at a total assay time of only 75 s. This technique is very promising for sensitive, and potentially spatially resolved, optical absorbance detection on the micro- and nanoscale.
Collapse
|
26
|
Micro free-flow isoelectric focusing with integrated optical pH sensors. Eng Life Sci 2017; 18:114-123. [PMID: 32624893 DOI: 10.1002/elsc.201700035] [Citation(s) in RCA: 10] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/20/2017] [Revised: 02/07/2017] [Accepted: 07/13/2017] [Indexed: 01/12/2023] Open
Abstract
Recently, a new observation method for monitoring of pH gradients in microfluidic free-flow electrophoresis has emerged. It is based on the use of chip-integrated fluorescent or luminescent micro sensor layers. These are able to monitor pH gradients in miniaturized separations in real time and spatially resolved; this is particularly useful in isoelectric focusing. Here these multifunctional microdevices that feature continuous separation, monitoring, and in some instances other functionalities, are reviewed. The employed microfabrication procedures to produce these devices are discussed and the different pH sensor matrices that were integrated and their applications in the separation of different types of biomolecules. The procedures for obtaining spatially resolved information about the separated molecules and the pH at the same time and different detection modalities to achieve this such as deep UV fluorescence as well as time-resolved referenced pH sensing and the integration of a precolumn labeling step into these platforms are also highlighted.
Collapse
|
27
|
Abstract
It is commonly assumed that the substantial element of reversibly actuating soft polymeric materials is chemical cross-linking, which is needed to provide elasticity required for the reversible actuation. On the example of melt spun and three-dimensional printed Janus fibers, we demonstrate here for the first time that cross-linking is not an obligatory prerequisite for reversible actuation of solid entangled polymers, since the entanglement network itself can build elasticity during crystallization. Indeed, we show that not-cross-linked polymers, which typically demonstrate plastic deformation in melt, possess enough elastic behavior to actuate reversibly. The Janus polymeric structure bends because of contraction of the polymer and due to entanglements and formation of nanocrystallites upon cooling. Actuation upon melting is simply due to relaxation of the stressed nonfusible component. This approach opens perspectives for design of solid active materials and actuator for robotics, biotechnology, and smart textile applications. The great advantage of our principle is that it allows design of non-cross-linked self-moving materials, which are able to actuate in both water and air, which are not cross-linked. We demonstrate application of actuating fibers for design of walkers, structures with switchable length, width, and thickness, which can be used for smart textile applications.
Collapse
|
28
|
In situ integration of graphene foam-titanium nitride based bio-scaffolds and microfluidic structures for soil nutrient sensors. LAB ON A CHIP 2017; 17:274-285. [PMID: 28009868 DOI: 10.1039/c6lc01266c] [Citation(s) in RCA: 10] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/06/2023]
Abstract
It is challenging to integrate porous graphene foam (GF) and GF-based nanocomposites into microfluidic channels and even create microfluidic structures within these materials. This is because their irregular interior pore shape and geometry, rough exterior surface, and relatively large material thickness make it difficult to perform conventional photolithography and etching. This challenge has largely hindered the potential of using GF-based materials in microfluidics-based sensors. Here we present a simple approach to create well-defined flow-through channels within or across the GF-based materials, using a liquid-phase photopolymerization method. This method allows embedding of a nanocomposite-based scaffold of GF and titanium nitride nanofibers (GF-TiN NFs) into a channel structure, to realize flow-through microfluidic electrochemical sensors for detecting nitrate ions in agricultural soils. The unique GF-TiN nanocomposite provides high electrochemical reactivity, high electron transfer rate, improved loading capacity of receptor biomolecules, and large surface area, serving as an efficient electrochemical sensing interface with the help of immobilized specific enzyme molecules. The microfluidic sensor provides an ultralow limit of detection of 0.01 mg L-1, a wide dynamic range from 0.01 to 442 mg L-1, and a high sensitivity of 683.3 μA mg-1 L cm-2 for nitrate ions in real soil solution samples. The advantageous features of the GF-TiN nanocomposite, in conjunction with the in situ integration approach, will enable a promising microfluidic sensor platform to monitor soil ions for nutrient management towards sustainable agriculture.
Collapse
|
29
|
An autonomous electrochemically-actuated microvalve for controlled transport in stand-alone microfluidic systems. RSC Adv 2017. [DOI: 10.1039/c7ra07335f] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/21/2022] Open
Abstract
An autonomous stand-alone microfluidic system using an electrochemically-actuated microvalve based on a single bi-metallic Zn/Pt electrode.
Collapse
|
30
|
Abstract
We present a method of creating three dimensional microfluidic channel networks and freestanding microstructures using liquid phase photopolymerization techniques. The use of liquid phase microfabrication facilitates the creation of microstructured devices using low-cost materials and equipment. The ability to add multiple layers allows for complex geometries and increases the functional density of channeled devices. The multilayer technique provides a method of interconnecting layers or combining separate layers to form a truly integrated multilayered microfluidic device, as well as a means of forming multilayered freestanding structures. Because this method is based on the fundamentals of microfluidic tectonics (μFT), all components (valves, mixers, filters) compatible with μFT can be integrated into the multilayer channel networks.
Collapse
|
31
|
A Reversibly Sealed, Easy Access, Modular (SEAM) Microfluidic Architecture to Establish In Vitro Tissue Interfaces. PLoS One 2016; 11:e0156341. [PMID: 27227828 PMCID: PMC4881956 DOI: 10.1371/journal.pone.0156341] [Citation(s) in RCA: 30] [Impact Index Per Article: 3.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/26/2015] [Accepted: 05/12/2016] [Indexed: 11/19/2022] Open
Abstract
Microfluidic barrier tissue models have emerged as advanced in vitro tools to explore interactions with external stimuli such as drug candidates, pathogens, or toxins. However, the procedures required to establish and maintain these systems can be challenging to implement for end users, particularly those without significant in-house engineering expertise. Here we present a module-based approach that provides an easy-to-use workflow to establish, maintain, and analyze microscale tissue constructs. Our approach begins with a removable culture insert that is magnetically coupled, decoupled, and transferred between standalone, prefabricated microfluidic modules for simplified cell seeding, culture, and downstream analysis. The modular approach allows several options for perfusion including standard syringe pumps or integration with a self-contained gravity-fed module for simple cell maintenance. As proof of concept, we establish a culture of primary human microvascular endothelial cells (HMVEC) and report combined surface protein imaging and gene expression after controlled apical stimulation with the bacterial endotoxin lipopolysaccharide (LPS). We also demonstrate the feasibility of incorporating hydrated biomaterial interfaces into the microfluidic architecture by integrating an ultra-thin (< 1 μm), self-assembled hyaluronic acid/peptide amphiphile culture membrane with brain-specific Young’s modulus (~ 1kPa). To highlight the importance of including biomimetic interfaces into microscale models we report multi-tiered readouts from primary rat cortical cells cultured on the self-assembled membrane and compare a panel of mRNA targets with primary brain tissue signatures. We anticipate that the modular approach and simplified operational workflows presented here will enable a wide range of research groups to incorporate microfluidic barrier tissue models into their work.
Collapse
|
32
|
Microfluidics using a thiol-acrylate resin for fluorescence-based pathogen detection assays. LAB ON A CHIP 2015; 15:4227-4231. [PMID: 26371689 DOI: 10.1039/c5lc00971e] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/05/2023]
Abstract
We demonstrate thiol-acrylate microfluidics prepared via soft lithography for single-step protein immobilization and fluorescence-based pathogen detection. Such microfluidics are formed via room temperature curing, and bonded without oxygen plasma. The background fluorescence of the resin was found to be similar to PDMS for several filter sets. We also show that thiol-acrylate devices are able to bond to gold-coated surfaces, which allows for integration with microfabricated sensors.
Collapse
|
33
|
Rapid prototyping of microfluidic chips for dead-volume-free MS coupling. Anal Bioanal Chem 2015; 407:8735-43. [DOI: 10.1007/s00216-015-9027-1] [Citation(s) in RCA: 8] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/24/2015] [Revised: 08/20/2015] [Accepted: 09/03/2015] [Indexed: 11/30/2022]
|
34
|
UV-Induced Micropatterning of Complex Functional Surfaces by Photopolymerization Controlled by Alkoxyamines. LANGMUIR : THE ACS JOURNAL OF SURFACES AND COLLOIDS 2015; 31:10026-10036. [PMID: 26301751 DOI: 10.1021/acs.langmuir.5b01681] [Citation(s) in RCA: 18] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/04/2023]
Abstract
We report on the use of an alkoxyamine (AA) for fabrication of functional micropatterns with complex structures by UV mask lithography. The living character of the polymer surface and the vertical spatial control of the repolymerization reaction from few tens of nanometers to few micrometers were demonstrated. The impact of the main parameters governing the controlled polymerization and the reinitiation process activated by light or heat was investigated. Micropatterning is shown to be a powerful method to investigate the physicochemical molecular phenomena. It is possible to control the polymer microstructure thickness from few tens of nanometers to few micrometers. In the last section, some applications are provided showing the potential of the AA for generating covalently bonded hydrophilic/hydrophobic micropatterns or luminescent surfaces. This demonstrates the high versatility and interest of this route.
Collapse
|
35
|
Abstract
Actuators are materials and devices that are able to change their shape in response to changes in environmental conditions and perform mechanical work on nano-, micro-, and macroscales. Among the huge variety of different actuators, polymer-based ones are highly attractive because of a number of properties such as sensitivity to a broad range of stimuli and good mechanical properties. The goal of this review is to provide a general picture of different mechanisms and working principles of polymeric actuators as well as to show a palette of their applications.
Collapse
|
36
|
Reversible thermosensitive biodegradable polymeric actuators based on confined crystallization. NANO LETTERS 2015; 15:1786-90. [PMID: 25650779 DOI: 10.1021/nl5045023] [Citation(s) in RCA: 32] [Impact Index Per Article: 3.6] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/22/2023]
Abstract
We discovered a new and unexpected effect of reversible actuation of ultrathin semicrystalline polymer films. The principle was demonstrated on the example of thin polycaprolactone-gelatin bilayer films. These films are unfolded at room temperature, fold at temperature above polycaprolactone melting point, and unfold again at room temperature. The actuation is based on reversible switching of the structure of the hydrophobic polymer (polycaprolactone) upon melting and crystallization. We hypothesize that the origin of this unexpected behavior is the orientation of polycaprolactone chains parallel to the surface of the film, which is retained even after melting and crystallization of the polymer or the "crystallization memory effect". In this way, the crystallization generates a directed force, which causes bending of the film. We used this effect for the design of new generation of fully biodegradable thermoresponsive polymeric actuators, which are highly desirable for bionano-technological applications such as reversible encapsulation of cells and design of swimmers.
Collapse
|
37
|
Surface protein gradients generated in sealed microchannels using spatially varying helium microplasma. BIOMICROFLUIDICS 2015; 9:014124. [PMID: 25759757 PMCID: PMC4336250 DOI: 10.1063/1.4913367] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 12/15/2014] [Accepted: 02/11/2015] [Indexed: 06/04/2023]
Abstract
Spatially varied surface treatment of a fluorescently labeled Bovine Serum Albumin (BSA) protein, on the walls of a closed (sealed) microchannel is achieved via a well-defined gradient in plasma intensity. The microchips comprised a microchannel positioned in-between two microelectrodes (embedded in the chip) with a variable electrode separation along the length of the channel. The channel and electrodes were 50 μm and 100 μm wide, respectively, 50 μm deep, and adjacent to the channel for a length of 18 mm. The electrode separation distance was varied linearly from 50 μm at one end of the channel to a maximum distance of 150, 300, 500, or 1000 μm to generate a gradient in helium plasma intensity. Plasma ignition was achieved at a helium flow rate of 2.5 ml/min, 8.5 kVpk-pk, and 10 kHz. It is shown that the plasma intensity decreases with increasing electrode separation and is directly related to the residual amount of BSA left after the treatment. The plasma intensity and surface protein gradient, for the different electrode gradients studied, collapse onto master curves when plotted against electrode separation. This precise spatial control is expected to enable the surface protein gradient to be tuned for a range of applications, including high-throughput screening and cell-biomolecule-biomaterial interactions.
Collapse
|
38
|
Effect of tensile load on the actuation performance of pH-sensitive hydrogels. ACTA ACUST UNITED AC 2014. [DOI: 10.1002/polb.23639] [Citation(s) in RCA: 7] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/07/2022]
|
39
|
Rapid Isoelectric Point Determination in a Miniaturized Preparative Separation Using Jet-Dispensed Optical pH Sensors and Micro Free-Flow Electrophoresis. Anal Chem 2014; 86:9533-9. [DOI: 10.1021/ac501783r] [Citation(s) in RCA: 26] [Impact Index Per Article: 2.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/05/2023]
|
40
|
Abstract
In this review, we highlight the properties, functions and applications of stimuli-responsive hydrogel patterns in bioanalytical applications. Stimuli-responsive hydrogel patterns can be realized by well-established micro- and nanofabrication technologies such as photolithography and micromolding, and are currently adopted as active components for manipulation of flow and biosamples in microchannel and microarray systems. We overview the properties of stimuli-responsive hydrogel materials and their fabrication methods along with some representative examples in microfluidics and microarrays.
Collapse
|
41
|
A simple strategy for in situ fabrication of a smart hydrogel microvalve within microchannels for thermostatic control. LAB ON A CHIP 2014; 14:2626-2634. [PMID: 24810920 DOI: 10.1039/c4lc00039k] [Citation(s) in RCA: 8] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/03/2023]
Abstract
Self-regulation of temperature in microchip systems is crucial for their applications in biomedical fields such as cell culture and biomolecule synthesis as well as those cases that require constant temperature conditions. Here we report on a simple and versatile approach for in situ fabrication of a smart hydrogel microvalve within a microchip for thermostatic control. The thermo-responsive hydrogel microvalve enables the "on-off" switch by sensing temperature fluctuations to control the fluid flux as well as the fluid heat exchange for self-regulation of the temperature at a constant range. Such temperature self-regulation is demonstrated by integrating the microvalve-incorporated microchip into the flow circulation loop of a micro-heat-exchanging system for thermostatic control. Moreover, the microvalve-incorporated microchip is employed for culturing cells under temperature self-regulation. The smart microvalve shows great potential as a temperature controller for applications that require thermostatic conditions. This approach offers a facile and flexible strategy for in situ fabricating hydrogel microvalves within microchips as chemostats and microreactors for biomedical applications.
Collapse
|
42
|
Recent advances in bioprinting and applications for biosensing. BIOSENSORS 2014; 4:111-36. [PMID: 25587413 PMCID: PMC4264374 DOI: 10.3390/bios4020111] [Citation(s) in RCA: 61] [Impact Index Per Article: 6.1] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 02/18/2014] [Revised: 04/12/2014] [Accepted: 04/18/2014] [Indexed: 12/19/2022]
Abstract
Future biosensing applications will require high performance, including real-time monitoring of physiological events, incorporation of biosensors into feedback-based devices, detection of toxins, and advanced diagnostics. Such functionality will necessitate biosensors with increased sensitivity, specificity, and throughput, as well as the ability to simultaneously detect multiple analytes. While these demands have yet to be fully realized, recent advances in biofabrication may allow sensors to achieve the high spatial sensitivity required, and bring us closer to achieving devices with these capabilities. To this end, we review recent advances in biofabrication techniques that may enable cutting-edge biosensors. In particular, we focus on bioprinting techniques (e.g., microcontact printing, inkjet printing, and laser direct-write) that may prove pivotal to biosensor fabrication and scaling. Recent biosensors have employed these fabrication techniques with success, and further development may enable higher performance, including multiplexing multiple analytes or cell types within a single biosensor. We also review recent advances in 3D bioprinting, and explore their potential to create biosensors with live cells encapsulated in 3D microenvironments. Such advances in biofabrication will expand biosensor utility and availability, with impact realized in many interdisciplinary fields, as well as in the clinic.
Collapse
|
43
|
Rapid prototyping of electrochromatography chips for improved two-photon excited fluorescence detection. Anal Chem 2014; 86:3773-9. [PMID: 24666258 DOI: 10.1021/ac500793e] [Citation(s) in RCA: 14] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/28/2022]
Abstract
In the present study, we introduce two-photon excitation at 532 nm for label-free fluorescence detection in chip electrochromatography. Two-photon excitation at 532 nm offers a promising alternative to one-photon excitation at 266 nm, as it enables the use of economic chip materials instead of fused silica. In order to demonstrate these benefits, one-photon and two-photon induced fluorescence detection are compared in different chip layouts and materials with respect to the achievable sensitivity in the detection of polycyclic aromatic hydrocarbons (PAHs). Customized chromatography chips with cover or bottom slides of different material and thickness are produced by means of a rapid prototyping method based on liquid-phase lithography. The design of thin bottom chips (180 μm) enables the use of high-performance immersion objectives with low working distances, which allows one to exploit the full potential of two-photon excitation for a sensitive detection. The developed method is applied for label-free analysis of PAHs separated on a polymer monolith inside polymer glass sandwich chips made from fused silica or soda-lime glass. The obtained limits of detection range from 40 nM to 1.95 μM, with similar sensitivities in fused silica thin bottom chips for one-photon and two-photon excitation. In deep-UV non- or less-transparent devices two-photon excitation is mandatory for label-free detection of aromatics with high sensitivity.
Collapse
|
44
|
Abstract
Centrifugal microfluidic platforms have emerged as point-of-care diagnostic tools. However, the unidirectional nature of the centrifugal force limits the available space for multi-step processes on a single microfluidic disc. To overcome this limitation, a passive pneumatic pumping method actuated at high rotational speeds has been previously proposed to pump liquid against the centrifugal force. In this paper, a novel micro-balloon pumping method that relies on elastic energy stored in a latex membrane is introduced. It operates at low rotational speeds and pumps a larger volume of liquid towards the centre of the disc. Two different micro-balloon pumping mechanisms have been designed to study the pump performance at a range of rotational frequencies from 0 to 1500 rpm. The behaviour of the micro-balloon pump on the centrifugal microfluidic platforms has been theoretically analysed and compared with the experimental data. The experimental data show that the developed pumping method dramatically decreases the required rotational speed to pump liquid compared to the previously developed pneumatic pumping methods. It also shows that within a range of rotational speed, a desirable volume of liquid can be stored and pumped by adjusting the size of the micro-balloon.
Collapse
|
45
|
Bell-shaped superhydrophilic-superhydrophobic-superhydrophilic double transformation on a pH-responsive smart surface. ADVANCED MATERIALS (DEERFIELD BEACH, FLA.) 2014; 26:306-10. [PMID: 24123523 DOI: 10.1002/adma.201302187] [Citation(s) in RCA: 47] [Impact Index Per Article: 4.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 05/14/2013] [Revised: 07/16/2013] [Indexed: 05/16/2023]
Abstract
Superhydrophobic to neutral water droplets, superhydrophilic to acidic or basic. This double transition of surface wettability in response to a single stimulus - pH - is demonstrated for the first time. The smart surface is composed of a rough gold surface modified with a self-assembled monolayer (SAM) containing three thiols, HS(CH2 )11 CH3 , HS(CH2 )10 COOH, and HS(CH2 )11 NH2 . A ternary diagram is generated that describes wettability as a function of the SAM composition and the pH of the surrounding solution.
Collapse
|
46
|
|
47
|
Novel Phenotypic Fluorescent Three-Dimensional Co-Culture Platforms for Recapitulating Tumor in vivo Progression and for Personalized Therapy. J Cancer 2013; 4:755-63. [PMID: 24312145 PMCID: PMC3842444 DOI: 10.7150/jca.7813] [Citation(s) in RCA: 10] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/03/2013] [Accepted: 10/19/2013] [Indexed: 12/12/2022] Open
Abstract
Because three-dimensional (3D) in vitro models are more accurate than 2D cell culture models and faster and cheaper than animal models, they have become a prospective trend in the biomedical and pharmaceutical fields, especially for personalized and targeted therapies. Because appropriate 3D models can be customized to mimic the in vivo microenvironment wherein various cell populations grow within an intricate but well organized extracellular matrix (ECM), they can accurately recapitulate physiological and pathophysiological progressions. The majority of cancers are carcinomas, which originate from epithelial cells, and dynamically interact with non-malignant cells including stromal cells (fibroblasts), vascular cells (endothelial cells and pericytes), immune cells (macrophages and mast cells), and the ECM. Employing a tumor monoclonal colony, tumor xenograft or patient cancer biopsy into an in vivo-like microenvironment, the native signaling pathways, cell-cell and cell-matrix interactions, and cell phenotypes are preserved and our fluorescent phenotypic 3D co-culture platforms can then accurately recapitulate the tumor in vivo scenario including tumor induced angiogenesis, tumor growth, and metastasis. In this paper, we describe a robust and standardized method to co-culture a tumor colony or biopsy with different cell populations, e.g., endothelial cells, immune cells, pericytes, etc. The procedures for recovering cells from the co-culture for molecular analyses, imaging, and analyzing are also described. We selected ECM solubilized extract derived from Engelbreth-Holm-Swam sarcoma cells. Because the 3D co-culture platforms can provide drug chemosensitivity data within 9 days that is equivalent to the results generated from mouse tumor xenograft models in 50 days, the 3D co-culture platforms are more accurate, efficient, and cost-effective and may replace animal models in the near future to predict drug efficacy, personalize therapies, prevent drug resistance, and improve the quality of life.
Collapse
|
48
|
Monodisperse polymeric ionic liquid microgel beads with multiple chemically switchable functionalities. LANGMUIR : THE ACS JOURNAL OF SURFACES AND COLLOIDS 2013; 29:9535-9543. [PMID: 23805857 DOI: 10.1021/la401613w] [Citation(s) in RCA: 37] [Impact Index Per Article: 3.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/02/2023]
Abstract
We present simple, inexpensive microfluidics-based fabrication of highly monodisperse poly(ionic liquid) microgel beads with a multitude of functionalities that can be chemically switched in facile fashion by anion exchange and further enhanced by molecular inclusion. Specifically, we show how the exquisite control over bead size and shape enables extremely precise, quantitative measurements of anion- and solvent-induced volume transitions in these materials, a crucial feature driving several important applications. Next, by exchanging diverse anions into the synthesized microgel beads, we demonstrate stimuli responsiveness and a multitude of novel functionalities including redox response, controlled release of chemical payloads, magnetization, toxic metal removal from water, and robust, reversible pH sensing. These chemically switchable stimulus-responsive beads are envisioned to open up a vast array of potential applications in portable and preparative chemical analysis, separations and spatially addressed sensing.
Collapse
|
49
|
Protein immobilization techniques for microfluidic assays. BIOMICROFLUIDICS 2013; 7:41501. [PMID: 24003344 PMCID: PMC3747845 DOI: 10.1063/1.4816934] [Citation(s) in RCA: 214] [Impact Index Per Article: 19.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 06/09/2013] [Accepted: 07/16/2013] [Indexed: 05/07/2023]
Abstract
Microfluidic systems have shown unequivocal performance improvements over conventional bench-top assays across a range of performance metrics. For example, specific advances have been made in reagent consumption, throughput, integration of multiple assay steps, assay automation, and multiplexing capability. For heterogeneous systems, controlled immobilization of reactants is essential for reliable, sensitive detection of analytes. In most cases, protein immobilization densities are maximized, while native activity and conformation are maintained. Immobilization methods and chemistries vary significantly depending on immobilization surface, protein properties, and specific assay goals. In this review, we present trade-offs considerations for common immobilization surface materials. We overview immobilization methods and chemistries, and discuss studies exemplar of key approaches-here with a specific emphasis on immunoassays and enzymatic reactors. Recent "smart immobilization" methods including the use of light, electrochemical, thermal, and chemical stimuli to attach and detach proteins on demand with precise spatial control are highlighted. Spatially encoded protein immobilization using DNA hybridization for multiplexed assays and reversible protein immobilization surfaces for repeatable assay are introduced as immobilization methods. We also describe multifunctional surface coatings that can perform tasks that were, until recently, relegated to multiple functional coatings. We consider the microfluidics literature from 1997 to present and close with a perspective on future approaches to protein immobilization.
Collapse
|
50
|
A photoinduced nanoparticle separation in microchannels via pH-sensitive surface traps. LANGMUIR : THE ACS JOURNAL OF SURFACES AND COLLOIDS 2013; 29:5388-93. [PMID: 23581256 PMCID: PMC3742372 DOI: 10.1021/la400347r] [Citation(s) in RCA: 12] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/07/2023]
Abstract
A microfluidic surface trap was developed for capturing pH-sensitive nanoparticles via a photoinitiated proton-releasing reaction of o-nitrobenzaldehyde (o-NBA) that reduces the solution pH in microchannels. The surface trap and nanoparticles were both modified with a pH-responsive polymer-poly(N-isorpopylacylamide-co-propylacrylic acid), P(NIPAAm-co-PAA). The o-NBA-coated microchannel walls demonstrated rapid proton release upon UV light irradiation, allowing the buffered solution pH in the microchannel to decrease from 7.4 to 4.5 in 60 s. The low solution pH switched the polymer-modified surfaces to be more hydrophobic, which enabled the capture of the pH-sensitive nanobeads onto the trap. When a photomask was utilized to limit the UV irradiation to a specific channel region, we were able to restrict the particle separation to only the exposed region. Via control of the UV irradiation, this technique enables not only prompt pH changes within the channel but also the capture of target molecules at specific channel locations.
Collapse
|