1
|
Tawfik KO, Khan MMR, Patro A, Smetak MR, Haynes D, Labadie RF, Gifford RH, Noble JH. Cochlear Implantation of Slim Precurved Arrays Using Automatic Preoperative Insertion Plans. Otol Neurotol 2025:00129492-990000000-00809. [PMID: 40364437 DOI: 10.1097/mao.0000000000004525] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 05/15/2025]
Abstract
HYPOTHESIS Preoperative cochlear implant (CI) electrode array (EL) insertion plans created by automated image analysis methods can improve positioning of slim precurved EL. BACKGROUND This study represents the first evaluation of a system for patient-customized EL insertion planning for a slim precurved EL. METHODS Twenty-one temporal bone specimens were divided into experimental and control groups and underwent cochlear implantation. For the control group, the surgeon performed a traditional insertion without an insertion plan. For the experimental group, customized insertion plans guided entry site, trajectory, curl direction, and base insertion depth. An additional 35 clinical insertions from the same surgeon were analyzed, 7 of which were conducted using the insertion plans. EL positioning was analyzed using postoperative imaging auto-segmentation techniques, allowing measurement of angular insertion depth (AID), mean modiolar distance (MMD), and scalar position. RESULTS In the cadaveric temporal bones, three scalar translocations, including two foldovers, occurred in 14 control group insertions. In the clinical insertions, translocations occurred in 2 of 28 control cases. No translocations or folds occurred in the seven experimental temporal bone and the seven experimental clinical insertions. Among the nontranslocated cases, overall AID and MMD were 401 ± 41 degrees and 0.34 ± 0.13 mm for the control insertions. AID and MMD for the experimental insertions were 424 ± 43 degrees and 0.34 ± 0.09 mm overall and were 432 ± 19 degrees and 0.30 ± 0.07 mm for cases where the planned insertion depth was achieved. CONCLUSIONS Trends toward improved EL positioning within scala tympani were observed when EL insertion plans are used. Variability in MMD was significantly reduced (0.07 versus 0.13 mm, p = 0.039) when the planned depth was achieved.
Collapse
Affiliation(s)
- Kareem O Tawfik
- Department of Otolaryngology-Head & Neck Surgery, Vanderbilt University Medical Center, Nashville, Tennessee
| | - Mohammad M R Khan
- Department of Computer and Data Science, Meharry Medical College, Nashville, Tennessee
| | - Ankita Patro
- Department of Otolaryngology-Head & Neck Surgery, Vanderbilt University Medical Center, Nashville, Tennessee
| | - Miriam R Smetak
- Department of Otolaryngology-Head & Neck Surgery, Washington University School of Medicine, St. Louis, Missouri
| | - David Haynes
- Department of Otolaryngology-Head & Neck Surgery, Vanderbilt University Medical Center, Nashville, Tennessee
| | - Robert F Labadie
- Department of Otolaryngology-Head & Neck Surgery, Medical University of South Carolina, Charleston, South Carolina
| | | | | |
Collapse
|
2
|
Berg KA, Noble JH, Dawant BM, Sunderhaus LW, DeFreese AJ, Labadie RF, Gifford RH. Cochlear Implant Electrode Placement and Music Perception. JAMA Otolaryngol Head Neck Surg 2025; 151:220-227. [PMID: 39786766 PMCID: PMC11907309 DOI: 10.1001/jamaoto.2024.4761] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/31/2024] [Accepted: 11/10/2024] [Indexed: 01/12/2025]
Abstract
Importance Cochlear implants enable improvements in speech perception, but music perception outcomes remain variable. Image-guided cochlear implant programming has emerged as a potential programming strategy for increasing the quality of spectral information delivered through the cochlear implant to improve outcomes. Objectives To perform 2 experiments, the first of which modeled the variance in music perception scores as a function of electrode positioning factors, and the second of which evaluated image-guided cochlear implant programming as a strategy to improve music perception with a cochlear implant. Design, Setting, and Participants This single-center, prospective study recruited 50 adult patients with at least 6 months of cochlear implant listening experience and normal cochlear anatomy to participate in experiment 1 from 2013 to 2023. Data analysis was conducted from January to February 2024. Thirty-four of the 50 patients from experiment 1 also completed experiment 2. Interventions Cochlear implant programming using a computed tomography-guided electrode selection strategy. Main Outcomes and Measures University of Washington Clinical Assessment of Music score, including subtests of pitch discrimination thresholds, isochronous familiar melody recognition, and timbre recognition. Results Of 50 participants, 20 (40%) were female, and the mean (SD) age was 57.7 (16.4) years. Experiment 1 suggested that better music perception abilities in the 50 participants were associated with patients who were younger and had a postlingual onset of deafness, as well as electrode arrays with a full scala tympani insertion, higher modiolar distance, and shallower insertion depth. Experiment 2 suggested improvements in melody recognition in the 34 participants using the image-guided cochlear implant programming strategy. Patients with apical electrodes that were deactivated were more likely to demonstrate an improvement in their pitch perception thresholds with the image-guided strategy, likely due to the low-frequency stimuli used in the University of Washington Clinical Assessment of Music. Conclusions and Relevance This study identified patient and device factors that were associated with music perception outcomes with a cochlear implant. These findings suggest that a personalized, image-guided approach to programming may improve music perception abilities for patients with cochlear implants.
Collapse
Affiliation(s)
- Katelyn A. Berg
- Department of Hearing and Speech Sciences, Vanderbilt University Medical Center, Nashville, Tennessee
| | - Jack H. Noble
- Department of Electrical and Computer Engineering, Vanderbilt University, Nashville, Tennessee
| | - Benoit M. Dawant
- Department of Electrical and Computer Engineering, Vanderbilt University, Nashville, Tennessee
| | - Linsey W. Sunderhaus
- Department of Hearing and Speech Sciences, Vanderbilt University Medical Center, Nashville, Tennessee
| | - Andrea J. DeFreese
- Department of Hearing and Speech Sciences, Vanderbilt University Medical Center, Nashville, Tennessee
| | - Robert F. Labadie
- Department of Otolaryngology, Medical University of South Carolina, Charleston
| | - René H. Gifford
- Department of Hearing and Speech Sciences, Vanderbilt University Medical Center, Nashville, Tennessee
| |
Collapse
|
3
|
Duckett KA, Kassir MF, Munhall CC, Schvartz-Leyzac KC, Nguyen SA, Labadie RF. Does cochlear implant electrode array design affect audiologic outcomes? A systematic review and meta-analysis. Acta Otolaryngol 2025:1-17. [PMID: 39826150 DOI: 10.1080/00016489.2025.2451074] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/05/2024] [Accepted: 01/03/2025] [Indexed: 01/22/2025]
Abstract
BACKGROUND There is conflicting literature regarding whether cochlear implants (CI) electrode array (EA) selection impacts audiologic outcomes. OBJECTIVE To compare outcomes for the two EA designs, precurved and straight. METHODS A systematic search of CINAHL, Cochrane Library, PubMed, and SCOPUS was conducted according to PRISMA guidelines. Included studies reported word recognition scores, sentence recognition scores in quiet or noise, or hearing preservation (HP) rates for patients with post-lingual hearing loss who underwent CI with either EA type. Primary outcome measures included mean difference (baseline vs. post-surgery) and proportions (%) with 95% confidence intervals (CI). RESULTS Of 4134 unique abstracts screened, 92 studies (N = 5365 patients, 5658 ears) were included. Mean improvement of overall word recognition scores for patients with precurved EAs (46.5%, 95% CI: 43.13-49.88%) was significantly (p = 0.0009) superior to that of patients with straight EAs (36.33%; 95% CI, 31.4-41.27%). There was no significant difference between mean improvement of Azbio Quiet scores, mean improvement of overall sentences in noise scores, or HP or pure-tone averages between patients with precurved EAs and those with straight EAs. CONCLUSIONS Precurved EAs were superior in mean word recognition score improvement, but there was no superior EA design regarding sentence recognition or hearing preservation.
Collapse
Affiliation(s)
- Kelsey A Duckett
- Department of Otolaryngology - Head & Neck Surgery, Medical University of South Carolina, Charleston, South Carolina, USA
| | - Mohamed Faisal Kassir
- Department of Otolaryngology - Head & Neck Surgery, Medical University of South Carolina, Charleston, South Carolina, USA
| | - Christopher C Munhall
- Department of Otolaryngology - Head & Neck Surgery, Medical University of South Carolina, Charleston, South Carolina, USA
| | - Kara C Schvartz-Leyzac
- Department of Otolaryngology - Head & Neck Surgery, Medical University of South Carolina, Charleston, South Carolina, USA
| | - Shaun A Nguyen
- Department of Otolaryngology - Head & Neck Surgery, Medical University of South Carolina, Charleston, South Carolina, USA
| | - Robert F Labadie
- Department of Otolaryngology - Head & Neck Surgery, Medical University of South Carolina, Charleston, South Carolina, USA
| |
Collapse
|
4
|
Schaefer S, Sladen M, Nichani J, Millward K, Lockley M, O'Driscoll M, Kluk K, Bruce IA. Hearing preservation in paediatric cochlear implantation with the Nucleus Slim Straight Electrode - our experience. Int J Audiol 2025; 64:51-58. [PMID: 38319187 DOI: 10.1080/14992027.2024.2306191] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/20/2021] [Revised: 01/10/2024] [Accepted: 01/11/2024] [Indexed: 02/07/2024]
Abstract
OBJECTIVE to evaluate the levels of successful hearing preservation and preservation of functional hearing following cochlear implantation (HPCI) in children using the Cochlear Nucleus® Slim Straight Electrode (SSE). DESIGN retrospective case note review of paediatric HPCI cases in our CI centre from 2013 to 2023. Inclusion criteria were attempted hearing preservation surgery, SSE used for implantation, pre-operative hearing thresholds ≤80dBHL at 250 Hz, CI before 18 years of age. Patients were excluded if no postoperative unaided PTA was obtained (poor attendance). Primairy outcome was hearing preservation using the HEARRING group formula; secondary outcome was residual functional hearing (≤80dBHL at 250 Hz/<90dB LFPTA). STUDY SAMPLE 56 patients with 94 CI's were included for review. RESULTS Hearing preservation was achieved in 94.7% (89/94) of ears and complete preservation in 72% (68/94)). Average functional hearing was preserved in 89% using both criteria for preservation. Long-term follow up data was available for 36 ears (average 35.2 months), demonstrating 88.9% (32/36) complete preservation. CONCLUSION We have reliably achieved and maintained a high success rate of HPCI using the SSE in our paediatric population. The field of HPCI would benefit from unification of outcome reporting in order to optimise the evidence available to professionals, patients and their carers.
Collapse
Affiliation(s)
- Simone Schaefer
- Department of Paediatric Otolaryngology, Royal Manchester Children's Hospital, Manchester University NHS Foundation Trust, Manchester, UK
| | - Mark Sladen
- Richard Ramsden Centre for Auditory Implants, Manchester University NHS Foundation Trust, Manchester Academic Health Science Centre, Manchester, UK
| | - Jaya Nichani
- Department of Paediatric Otolaryngology, Royal Manchester Children's Hospital, Manchester University NHS Foundation Trust, Manchester, UK
| | - Kerri Millward
- Richard Ramsden Centre for Auditory Implants, Manchester University NHS Foundation Trust, Manchester Academic Health Science Centre, Manchester, UK
| | - Morag Lockley
- Richard Ramsden Centre for Auditory Implants, Manchester University NHS Foundation Trust, Manchester Academic Health Science Centre, Manchester, UK
| | - Martin O'Driscoll
- Richard Ramsden Centre for Auditory Implants, Manchester University NHS Foundation Trust, Manchester Academic Health Science Centre, Manchester, UK
| | - Karolina Kluk
- Manchester Centre for Audiology and Deafness (ManCAD), Faculty of Biology, Medicine and Health, The University of Manchester, Manchester, UK
| | - Iain A Bruce
- Department of Paediatric Otolaryngology, Royal Manchester Children's Hospital, Manchester University NHS Foundation Trust, Manchester, UK
- Division of Infection, Immunity and Respiratory Medicine, Faculty of Biology, Medicine and Health, University of Manchester, Manchester, UK
| |
Collapse
|
5
|
Berg K, Goldsworthy R, Noble J, Dawant B, Gifford R. The relationship between channel interaction, electrode placement, and speech perception in adult cochlear implant users. THE JOURNAL OF THE ACOUSTICAL SOCIETY OF AMERICA 2024; 156:4289-4302. [PMID: 39740049 DOI: 10.1121/10.0034603] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 05/20/2024] [Accepted: 11/18/2024] [Indexed: 01/02/2025]
Abstract
This study (1) characterized the effects of channel interaction using spectral blurring, (2) evaluated an image-guided electrode selection (IGES) method aiming to reduce channel interaction, and (3) investigated the impact of electrode placement factors on the change in performance by condition. Twelve adult MED-EL (Innsbruck, Austria) cochlear implant recipients participated. Performance was compared across six conditions: baseline (no blurring), all blurred, apical blurred, middle blurred, basal blurred, and IGES. Electrode placement information was calculated from post-insertion computerized tomography (CT) imaging. Each condition tested measures of speech recognition and subjective ratings. Results showed poorer performance when spectral blurring was applied to all channels compared to baseline, suggesting an increase in channel interaction was achieved. Vowel recognition was more sensitive to apical and middle blurring while consonant recognition was more sensitive to basal blurring, indicating that phoneme identification may be useful for assessing channel interaction clinically. IGES did not significantly improve group performance, and electrode placement factors did not impact results. However, participants who were more affected by spectral blurring tended to benefit more from IGES. These findings indicate that spectral blurring can help identify areas most affected by channel interaction to help optimize electrode selection.
Collapse
Affiliation(s)
- Katelyn Berg
- Vanderbilt University, Nashville, Tennessee 37232, USA
| | - Ray Goldsworthy
- University of Southern California, Los Angeles, California 90033, USA
| | - Jack Noble
- Vanderbilt University, Nashville, Tennessee 37232, USA
| | - Benoit Dawant
- Vanderbilt University, Nashville, Tennessee 37232, USA
| | - René Gifford
- Vanderbilt University, Nashville, Tennessee 37232, USA
| |
Collapse
|
6
|
Reiss LA, Lawrence MB, Omelchenko IA, He W, Kirk JR. Chronic Electro-Acoustic Stimulation May Interfere With Electric Threshold Recovery After Cochlear Implantation in the Aged Guinea Pig. Ear Hear 2024; 45:1554-1567. [PMID: 38992863 PMCID: PMC11493501 DOI: 10.1097/aud.0000000000001545] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 07/13/2024]
Abstract
OBJECTIVES Electro-acoustic stimulation (EAS) combines electric stimulation via a cochlear implant (CI) with residual low-frequency acoustic hearing, with benefits for music appreciation and speech perception in noise. However, many EAS CI users lose residual acoustic hearing, reducing this benefit. The main objectives of this study were to determine whether chronic EAS leads to more hearing loss compared with CI surgery alone in an aged guinea pig model, and to assess the relationship of any hearing loss to histology measures. Conversely, it is also important to understand factors impacting efficacy of electric stimulation. If one contributor to CI-induced hearing loss is damage to the auditory nerve, both acoustic and electric thresholds will be affected. Excitotoxicity from EAS may also affect electric thresholds, while electric stimulation is osteogenic and may increase electrode impedances. Hence, secondary objectives were to assess how electric thresholds are related to the amount of residual hearing loss after CI surgery, and how EAS affects electric thresholds and impedances over time. DESIGN Two groups of guinea pigs, aged 9 to 21 months, were implanted with a CI in the left ear. Preoperatively, the animals had a range of hearing losses, as expected for an aged cohort. At 4 weeks after surgery, the EAS group (n = 5) received chronic EAS for 8 hours a day, 5 days a week, for 20 weeks via a tether system that allowed for free movement during stimulation. The nonstimulated group (NS; n = 6) received no EAS over the same timeframe. Auditory brainstem responses (ABRs) and electrically evoked ABRs (EABRs) were recorded at 3 to 4 week intervals to assess changes in acoustic and electric thresholds over time. At 24 weeks after surgery, cochlear tissue was harvested for histological evaluation, only analyzing animals without electrode extrusions (n = 4 per ear). RESULTS Cochlear implantation led to an immediate worsening of ABR thresholds peaking between 3 and 5 weeks after surgery and then recovering and stabilizing by 5 and 8 weeks. Significantly greater ABR threshold shifts were seen in the implanted ears compared with contralateral, non-implanted control ears after surgery. After EAS and termination, no significant additional ABR threshold shifts were seen in the EAS group compared with the NS group. A surprising finding was that NS animals had significantly greater recovery in EABR thresholds over time, with decreases (improvements) of -51.8 ± 33.0 and -39.0 ± 37.3 c.u. at 12 and 24 weeks, respectively, compared with EAS animals with EABR threshold increases (worsening) of +1.0 ± 25.6 and 12.8 ± 44.3 c.u. at 12 and 24 weeks. Impedance changes over time did not differ significantly between groups. After exclusion of cases with electrode extrusion or significant trauma, no significant correlations were seen between ABR and EABR thresholds, or between ABR thresholds with histology measures of inner/outer hair cell counts, synaptic ribbon counts, stria vascularis capillary diameters, or spiral ganglion cell density. CONCLUSIONS The findings do not indicate that EAS significantly disrupts acoustic hearing, although the small sample size limits this interpretation. No evidence of associations between hair cell, synaptic ribbon, spiral ganglion cell, or stria vascularis with hearing loss after cochlear implantation was seen when surgical trauma is minimized. In cases of major trauma, both acoustic thresholds and electric thresholds were elevated, which may explain why CI-only outcomes are often better when trauma and hearing loss are minimized. Surprisingly, chronic EAS (or electric stimulation alone) may negatively impact electric thresholds, possibly by prevention of recovery of the auditory nerve after CI surgery. More research is needed to confirm the potentially negative impact of chronic EAS on electric threshold recovery.
Collapse
Affiliation(s)
- Lina A.J. Reiss
- Department of Otolaryngology – Head and Neck Surgery, Oregon Health & Science University, Portland, OR
| | - Melissa B. Lawrence
- Department of Otolaryngology – Head and Neck Surgery, Oregon Health & Science University, Portland, OR
| | - Irina A. Omelchenko
- Department of Otolaryngology – Head and Neck Surgery, Oregon Health & Science University, Portland, OR
| | - Wenxuan He
- Department of Otolaryngology – Head and Neck Surgery, Oregon Health & Science University, Portland, OR
| | | |
Collapse
|
7
|
Berg KA, DeFreese AJ, Sisler-Dinwiddie AL, Labadie RF, Tawfik KO, Gifford RH. Clinical Applications for Spread of Excitation Functions Obtained Via Electrically Evoked Compound Action Potentials (eCAP). Otol Neurotol 2024; 45:790-797. [PMID: 38923968 DOI: 10.1097/mao.0000000000004242] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 06/28/2024]
Abstract
OBJECTIVES To assess the clinical utility of spread of excitation (SOE) functions obtained via electrically evoked compound action potentials (eCAP) to 1) identify electrode array tip fold-over, 2) predict electrode placement factors confirmed via postoperative computed tomography (CT) imaging, and 3) predict postoperative speech recognition through the first year post-activation in a large clinical sample. STUDY DESIGN Retrospective case review. SETTING Cochlear implant (CI) program at a tertiary medical center. PATIENTS Two hundred seventy-two ears (238 patients) with Cochlear Ltd. CIs (mean age = 46 yr, range = 9 mo-93 yr, 50% female) implanted between August 2014 and December 2022 were included. MAIN OUTCOME MEASURES eCAP SOE widths (mm) (probe electrodes 5, 11, and 17), incidence of electrode tip fold-over, CT imaging data (electrode-to-modiolus distance, angular insertion depth, scalar location), and speech recognition outcomes (consonant-nucleus-consonant [CNC], AzBio quiet, and +5 dB SNR) through the first year after CI activation. RESULTS 1) eCAP SOE demonstrated a sensitivity of 85.7% for identifying tip fold-over instances that were confirmed by CT imaging. In the current dataset, the tip fold-over incidence rate was 3.1% (7 patients), with all instances involving a precurved electrode array. 2) There was a significant positive relationship between eCAP SOE and mean electrode-to-modiolus distance for precurved arrays, and a significant positive relationship between eCAP SOE and angular insertion depth for straight arrays. No relationships between eCAP SOE and scalar location or cochlea diameter were found in this sample. 3) There were no significant relationships between eCAP SOE and speech recognition outcomes for any measure or time point, except for a weak negative correlation between average eCAP SOE widths and CNC word scores at 6 months post-activation for precurved arrays. CONCLUSIONS In the absence of intraoperative CT or fluoroscopic imaging, eCAP SOE is a reasonable alternative method for identifying electrode array tip fold-over and should be routinely measured intraoperatively, especially for precurved electrode arrays with a sheath.
Collapse
Affiliation(s)
- Katelyn A Berg
- Department of Hearing and Speech Sciences, Vanderbilt University Medical Center, Nashville, Tennessee
| | - Andrea J DeFreese
- Department of Hearing and Speech Sciences, Vanderbilt University Medical Center, Nashville, Tennessee
| | | | - Robert F Labadie
- Department of Otolaryngology-Head and Neck Surgery, Medical University of South Carolina, Charleston, South Carolina
| | | | - René H Gifford
- Department of Hearing and Speech Sciences, Vanderbilt University Medical Center, Nashville, Tennessee
| |
Collapse
|
8
|
Torres R, Daoudi H, Gu W, Breil E, Ferrary E, Sterkers O, Nguyen Y, Mosnier I. Exploring Trauma Patterns and Contributing Factors With Slim Straight Electrode Array After Cochlear Implantation. Otolaryngol Head Neck Surg 2024; 171:521-529. [PMID: 38532540 DOI: 10.1002/ohn.737] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/05/2023] [Revised: 02/09/2024] [Accepted: 02/29/2024] [Indexed: 03/28/2024]
Abstract
OBJECTIVE To assess trauma patterns associated with the insertion of lateral wall electrode arrays. The study focused on 3 categories-scala tympani (ST), intermediate, and scala vestibuli (SV)-to identify traumatic patterns and contributing factors. STUDY DESIGN Retrospective study. SETTING Data from 106 cochlear implant recipients at a tertiary otologic center. METHODS Demographic and surgical data were collected from recipients who underwent cochlear implantation manually and with RobOtol®. Measurements included cochlear dimensions, angular depth of insertion, and position of the first electrode. Three-dimensional reconstructions were used to analyze the electrode array location relative to the basilar membrane, categorized into ST, intermediate, and SV electrodes. Nontraumatic insertion was defined as all electrodes in the ST, while traumatic insertions had 1 or more electrodes in intermediate or SV locations. RESULTS Out of 106 cases, 44% had nontraumatic and 56% had traumatic insertions. Demographic and surgical characteristics showed no association with traumatic insertions. A deeper position of the first electrode, relative to the round window, was associated with traumatic insertions (P = .03). Three trauma patterns were observed: distal (facing the apical electrodes), proximal (facing the middle electrodes around 180°), and distal/proximal. CONCLUSION This study considers the intermediate position which could be associated with basilar membrane lesions. Risk zones for intracochlear trauma with lateral wall arrays were identified distally and proximally. Traumatic insertions were independently linked to deeper array placement. Future studies should explore whether gentler insertion, without insisting on further electrode array insertion depth, could reduce the trauma during cochlear implantation.
Collapse
Affiliation(s)
- Renato Torres
- Unité Fonctionnelle Implants Auditifs et Explorations Fonctionnelles, Service ORL, GHU Pitié-Salpêtrière, Assistance Publique-Hôpitaux de Paris (AP-HP)/Sorbonne Université, Paris, France
- Technologies et Thérapie Génique Pour la Surdité, Institut de l'Audition, Institut Pasteur/Inserm/Université Paris Cité, Paris, France
| | - Hannah Daoudi
- Unité Fonctionnelle Implants Auditifs et Explorations Fonctionnelles, Service ORL, GHU Pitié-Salpêtrière, Assistance Publique-Hôpitaux de Paris (AP-HP)/Sorbonne Université, Paris, France
- Technologies et Thérapie Génique Pour la Surdité, Institut de l'Audition, Institut Pasteur/Inserm/Université Paris Cité, Paris, France
| | - Wenxi Gu
- Unité Fonctionnelle Implants Auditifs et Explorations Fonctionnelles, Service ORL, GHU Pitié-Salpêtrière, Assistance Publique-Hôpitaux de Paris (AP-HP)/Sorbonne Université, Paris, France
- Technologies et Thérapie Génique Pour la Surdité, Institut de l'Audition, Institut Pasteur/Inserm/Université Paris Cité, Paris, France
- Department of Otolaryngology-Head and Neck Surgery, Shanghai Key Laboratory of Translational Medicine on Ear and Nose Diseases (14DZ2260300), Shanghai Ninth People's Hospital, Shanghai Jiao Tong University School of Medicine, Shanghai, China
| | - Eugénie Breil
- Unité Fonctionnelle Implants Auditifs et Explorations Fonctionnelles, Service ORL, GHU Pitié-Salpêtrière, Assistance Publique-Hôpitaux de Paris (AP-HP)/Sorbonne Université, Paris, France
| | - Evelyne Ferrary
- Unité Fonctionnelle Implants Auditifs et Explorations Fonctionnelles, Service ORL, GHU Pitié-Salpêtrière, Assistance Publique-Hôpitaux de Paris (AP-HP)/Sorbonne Université, Paris, France
- Technologies et Thérapie Génique Pour la Surdité, Institut de l'Audition, Institut Pasteur/Inserm/Université Paris Cité, Paris, France
| | - Olivier Sterkers
- Unité Fonctionnelle Implants Auditifs et Explorations Fonctionnelles, Service ORL, GHU Pitié-Salpêtrière, Assistance Publique-Hôpitaux de Paris (AP-HP)/Sorbonne Université, Paris, France
- Technologies et Thérapie Génique Pour la Surdité, Institut de l'Audition, Institut Pasteur/Inserm/Université Paris Cité, Paris, France
| | - Yann Nguyen
- Unité Fonctionnelle Implants Auditifs et Explorations Fonctionnelles, Service ORL, GHU Pitié-Salpêtrière, Assistance Publique-Hôpitaux de Paris (AP-HP)/Sorbonne Université, Paris, France
- Technologies et Thérapie Génique Pour la Surdité, Institut de l'Audition, Institut Pasteur/Inserm/Université Paris Cité, Paris, France
| | - Isabelle Mosnier
- Unité Fonctionnelle Implants Auditifs et Explorations Fonctionnelles, Service ORL, GHU Pitié-Salpêtrière, Assistance Publique-Hôpitaux de Paris (AP-HP)/Sorbonne Université, Paris, France
- Technologies et Thérapie Génique Pour la Surdité, Institut de l'Audition, Institut Pasteur/Inserm/Université Paris Cité, Paris, France
| |
Collapse
|
9
|
Hosoya M, Kurihara S, Koyama H, Komune N. Recent advances in Otology: Current landscape and future direction. Auris Nasus Larynx 2024; 51:605-616. [PMID: 38552424 DOI: 10.1016/j.anl.2024.02.009] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/22/2023] [Revised: 11/24/2023] [Accepted: 02/21/2024] [Indexed: 05/12/2024]
Abstract
Hearing is an essential sensation, and its deterioration leads to a significant decrease in the quality of life. Thus, great efforts have been made by otologists to preserve and recover hearing. Our knowledge regarding the field of otology has progressed with advances in technology, and otologists have sought to develop novel approaches in the field of otologic surgery to achieve higher hearing recovery or preservation rates. This requires knowledge regarding the anatomy of the temporal bone and the physiology of hearing. Basic research in the field of otology has progressed with advances in molecular biology and genetics. This review summarizes the current views and recent advances in the field of otology and otologic surgery, especially from the viewpoint of young Japanese clinician-scientists, and presents the perspectives and future directions for several topics in the field of otology. This review will aid next-generation researchers in understanding the recent advances and future challenges in the field of otology.
Collapse
Affiliation(s)
- Makoto Hosoya
- Department of Otolaryngology, Head and Neck Surgery, Keio University School of Medicine, Shinanomachi 35, Shinjuku-ku, Tokyo, 160-8582, Japan.
| | - Sho Kurihara
- Department of Otorhinolaryngology, The Jikei University School of Medicine, 3-25-8 Nishishimbashi Minato-ku, Tokyo, 105-8471, Japan
| | - Hajime Koyama
- Department of Otolaryngology and Head and Neck Surgery, Graduate School of Medicine, The University of Tokyo, Tokyo, 113-8654, Japan
| | - Noritaka Komune
- Department of Otorhinolaryngology, Graduate School of Medical Sciences, Kyushu University, 3-1-1Maidashi Higashi-ku, Fukuoka 812-8582, Japan
| |
Collapse
|
10
|
Kim JS. Clinical Applications of Intracochlear Electrocochleography in Cochlear Implant Users With Residual Acoustic Hearing. J Audiol Otol 2024; 28:100-106. [PMID: 38695055 PMCID: PMC11065546 DOI: 10.7874/jao.2024.00129] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/12/2024] [Accepted: 03/20/2024] [Indexed: 05/05/2024] Open
Abstract
We herein review the use of electrocochleography (ECoG) to assess peripheral auditory system responsiveness in a growing population of cochlear implant (CI) users with preserved hearing in ears with implants. Twenty-eight recently published intracochlear ECoG articles were thoroughly reviewed to investigate the prognostic utility of intraoperative ECoG monitoring to assess hearing preservation, and the clinical applicability of postoperative ECoG for estimating audiometric thresholds and monitoring longitudinal changes in residual acoustic hearing in patients with EAS. Intraoperative ECoG studies have focused on monitoring the changes in the cochlear microphonics (CM) amplitudes during and after electrode insertion. Mixed results have been reported regarding the relationship between changes in CM amplitude in the operating room and changes in hearing thresholds after surgery. Postoperative ECoG studies have shown that CM and auditory nerve neurophonics thresholds correlate significantly with behavioral thresholds. ECoG thresholds sensitively detect changes as residual acoustic hearing decreases over time in some CI users. This indicates its potential clinical value for monitoring the post-implantation status of the peripheral auditory system. Intracochlear ECoG can provide real-time intraoperative feedback and monitor postoperative hearing preservation in a growing population of CI users.
Collapse
Affiliation(s)
- Jeong-Seo Kim
- Hearing Research Laboratory, Samsung Medical Center, Seoul, Korea
- Medical Research Institute, Sungkyunkwan University, Suwon, Korea
| |
Collapse
|
11
|
Concheri S, Brotto D, Ariano M, Daloiso A, Di Pasquale Fiasca VM, Sorrentino F, Coppadoro B, Trevisi P, Zanoletti E, Franchella S. Intraoperative Measurement of Insertion Speed in Cochlear Implant Surgery: A Preliminary Experience with Cochlear SmartNav. Audiol Res 2024; 14:227-238. [PMID: 38525682 PMCID: PMC10961689 DOI: 10.3390/audiolres14020021] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/05/2023] [Revised: 02/18/2024] [Accepted: 02/19/2024] [Indexed: 03/26/2024] Open
Abstract
OBJECTIVES The objectives were to present the real-time estimated values of cochlear implant (CI) electrode insertion speed (IS) during intraoperative sessions using the Cochlear Nucleus SmartNav System to assess whether this measure affected CI outcomes and to determine whether real-time feedback assists expert surgeons in achieving slow insertion. METHODS The IS was measured in 52 consecutive patients (65 implanted ears) using the CI632 electrode. The IS values were analyzed in relation to procedure repetition over time, NRT ratio, and CI audiological outcomes. RESULTS The average IS was 0.64 mm/s (SD = 0.24); minimum and maximum values were 0.23 and 1.24 mm/s, respectively. The IS significantly decreased with each array insertion by the operator (p = 0.006), and the mean decreased by 24% between the first and last third of procedures; however, this reduction fell within the error range of SmartNav for IS (+/-0.48 mm/s). No correlation was found between IS and the NRT ratio (p = 0.51), pure-tone audiometry (PTA) at CI activation (p = 0.506), and PTA (p = 0.94) or word recognition score (p = 0.231) at last evaluation. CONCLUSIONS The estimated IS reported by SmartNav did not result in a clinically significant reduction in insertion speed or an improvement in CI hearing outcomes. Real-time feedback of IS could potentially be used for training, but its effectiveness requires confirmation through additional studies and more accurate tools. Implementation of IS assessment in clinical practice will enable comparisons between measurement techniques and between manual and robot-assisted insertions. This will help define the optimal IS range to achieve better cochlear implant (CI) outcomes.
Collapse
Affiliation(s)
- Stefano Concheri
- Department of Neurosciences, Section of Otolaryngology, Azienda Ospedale-Università Padova, 35121 Padua, Italy
| | - Davide Brotto
- Department of Neurosciences, Section of Otolaryngology, Azienda Ospedale-Università Padova, 35121 Padua, Italy
| | - Marzia Ariano
- Department of Neurosciences, Section of Otolaryngology, Azienda Ospedale-Università Padova, 35121 Padua, Italy
| | - Antonio Daloiso
- Department of Neurosciences, Section of Otolaryngology, Azienda Ospedale-Università Padova, 35121 Padua, Italy
| | | | - Flavia Sorrentino
- Department of Neurosciences, Section of Otolaryngology, Azienda Ospedale-Università Padova, 35121 Padua, Italy
| | - Beatrice Coppadoro
- Pediatric Hematology Oncology Unit, Department of Woman’s and Child’s Health, Azienda Ospedale-Università di Padova, 35122 Padua, Italy
| | - Patrizia Trevisi
- Department of Neurosciences, Section of Otolaryngology, Azienda Ospedale-Università Padova, 35121 Padua, Italy
| | - Elisabetta Zanoletti
- Department of Neurosciences, Section of Otolaryngology, Azienda Ospedale-Università Padova, 35121 Padua, Italy
| | - Sebastiano Franchella
- Department of Neurosciences, Section of Otolaryngology, Azienda Ospedale-Università Padova, 35121 Padua, Italy
| |
Collapse
|
12
|
Gerbert M, Ernst A, Seidl R, Decker L, Scholz S, Lauer G, Mittmann P. Preservation of Residual Hearing: Long-Term Results With a Mid-Scala Electrode. J Otolaryngol Head Neck Surg 2024; 53:19160216241250351. [PMID: 38888946 PMCID: PMC11155315 DOI: 10.1177/19160216241250351] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/29/2024] [Accepted: 03/30/2024] [Indexed: 06/20/2024] Open
Abstract
OBJECTIVE The long-term preservation of residual hearing after cochlear implantation has become a major goal over the past few years. The aim of the present study was to evaluate residual hearing in the long-term follow-up using mid-scala electrodes. METHODS In this retrospective, single-center study, we collected data from 27 patients who were implanted between 2014 and 2015 with residual hearing in the low-frequency range using a mid-scala electrode. Measurements of the hearing thresholds were carried out directly postoperatively (day 1 after surgery) and in the long-term follow-up 43.7 ± 6.9 months. The calculation of the extent of audiological hearing preservation was determined using the HEARRING group formula by Skarsynski. RESULTS Postoperative preservation of residual hearing was achieved in 69.2% of the cases in the low-frequency range between 250 Hz and 1 kHz, of which 89.5% of the patients had frequencies that suggested using electroacoustic stimulation (EAS). In the long-term follow-up, 30.8% of the patients showed residual hearing; however, 57.1% had apparently benefited from EAS. CONCLUSION Preservation of residual hearing is feasible in the long term using mid-scala electrodes. Postoperatively, there is over the half of patients who benefit from an EAS strategy. The long-term follow-up shows a certain decrease in residual hearing. However, these results are comparable to studies relating to other types of electrodes. Further research should be conducted in future to better evaluate hearing loss in long-term follow-up, compared to direct postoperative audiological results.
Collapse
Affiliation(s)
- Martin Gerbert
- Department of Otolaryngology, Head and Neck Surgery, Unfallkrankenhaus Berlin, Berlin, Germany
| | - Arne Ernst
- Department of Otolaryngology, Head and Neck Surgery, Unfallkrankenhaus Berlin, Berlin, Germany
| | - Rainer Seidl
- Department of Otolaryngology, Head and Neck Surgery, Unfallkrankenhaus Berlin, Berlin, Germany
| | - Lars Decker
- Department of Otolaryngology, Head and Neck Surgery, Unfallkrankenhaus Berlin, Berlin, Germany
| | - Sandra Scholz
- Department of Otolaryngology, Head and Neck Surgery, Unfallkrankenhaus Berlin, Berlin, Germany
| | - Gina Lauer
- Department of Otolaryngology, Head and Neck Surgery, Unfallkrankenhaus Berlin, Berlin, Germany
| | - Philipp Mittmann
- Department of Otolaryngology, Head and Neck Surgery, Unfallkrankenhaus Berlin, Berlin, Germany
| |
Collapse
|
13
|
Sipari S, Iso-Mustajärvi M, Linder P, Dietz A. Insertion Results and Hearing Outcomes of a Slim Lateral Wall Electrode. J Int Adv Otol 2024; 20:1-7. [PMID: 38454281 PMCID: PMC10895868 DOI: 10.5152/iao.2024.22962] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/14/2022] [Accepted: 05/14/2023] [Indexed: 03/09/2024] Open
Abstract
BACKGROUND The clinical outcomes of cochlear implantation vary for several reasons. It is necessary to study the different electrodes and variables for further development. The aim of this study is to report the clinical outcomes of a new slim lateral wall electrode (SlimJ). METHODS Data of 25 cochlear implantations in 23 patients with the SlimJ electrode were retrospectively collected. The insertion results were assessed by image fusion of the preoperative computed tomography (CT), magnetic resonance imaging (MRI), and postoperative cone-beam CT. The hearing outcomes were evaluated by the improvement of speech recognition in noise, measured preoperatively and at follow-up. Postoperative pure-tone thresholds were obtained in cases with preoperative functional low frequency hearing [PTA (0.125-0.5 kHz) ≤ 80 dB HL]. RESULTS The preoperative mean speech reception threshold (SRT) was +0.6 dB signal-to-noise ratio (SNR) (SD ± 4.2 dB) and the postoperative -3.5 dB SNR (SD ± 2.3 dB). The improvements between the preoperative and postoperative SRT levels ranged from 0.0 to 15.1 dB, with a mean improvement of 4.2 dB (SD ± 3.6 dB). Residual hearing in low frequencies (mean PTA(125-500 Hz)) was preserved within 30 dB HL in 70% and within 15 dB HL in 40% of patients who had preoperatively functional low frequency hearing. Mean insertion depth angle (IDA) was 401° (SD ± 41°). We observed scalar translocations from scala tympani to scala vestibuli in 2 ears (9%). CONCLUSION The relatively atraumatic insertion characteristics make the SlimJ array feasible for hearing preservation cochlear implantation. The hearing outcomes are comparable to those reported for other electrodes and devices.
Collapse
Affiliation(s)
- Sini Sipari
- Department of Otorhinolaryngology, Kuopio University Hospital, Kuopio, Finland
- Department of Clinical Medicine, University of Eastern Finland, Kuopio, Finland
| | - Matti Iso-Mustajärvi
- Department of Otorhinolaryngology, Kuopio University Hospital, Kuopio, Finland
- Department of Clinical Medicine, University of Eastern Finland, Kuopio, Finland
| | - Pia Linder
- Department of Otorhinolaryngology, Kuopio University Hospital, Kuopio, Finland
- Department of Clinical Medicine, University of Eastern Finland, Kuopio, Finland
| | - Aarno Dietz
- Department of Otorhinolaryngology, Kuopio University Hospital, Kuopio, Finland
- Department of Clinical Medicine, University of Eastern Finland, Kuopio, Finland
| |
Collapse
|
14
|
Gu W, Daoudi H, Lahlou G, Sterkers O, Ferrary E, Nguyen Y, Mosnier I, Torres R. Auditory outcomes after scala vestibuli array insertion are similar to those after scala tympani insertion 1 year after cochlear implantation. Eur Arch Otorhinolaryngol 2024; 281:155-162. [PMID: 37516989 DOI: 10.1007/s00405-023-08107-5] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/19/2023] [Accepted: 07/03/2023] [Indexed: 08/01/2023]
Abstract
PURPOSE In cochlear implantation, a scala vestibuli (SV) insertion of an electrode array is a rare occurrence and is reported to be linked to poor hearing outcomes. Using the same electrode array, the auditory performance of patients with a complete SV location was compared with that of patients having a complete scala tympani (ST) location 1 year after implantation. METHODS Thirty-three patients were included in this retrospective case-control study (SV, n = 12; ST, n = 21). The matching criteria were electrode array type, age at implantation, and duration of severe or profound deafness. The array location was analyzed using 3D reconstruction of postoperative CT scans. Postoperative audiological evaluation of the implanted ear was performed using pure-tone audiometry, speech recognition of monosyllabic words in quiet, and words and sentences in noise. RESULTS On the preoperative CT scan, six patients in the SV group presented with both round window (RW) and ST ossification, three with RW ossification alone, and three with no RW ossification. Auditory performance did not differ between SV and ST groups 1 year after cochlear implantation. Speech recognition of words was 49 ± 7.6% and 56 ± 5.0% in quiet and 75 ± 9.5% and 66 ± 6.0% in noise in SV and ST groups, respectively. CONCLUSION ST insertion is the gold standard that allows the three cochlear scalae to preserve scalar cochlear integrity. However, 1 year after implantation, a planned or unexpected SV insertion is not detrimental to hearing outcomes, providing similar auditory performance in quiet and noise to ST insertion.
Collapse
Affiliation(s)
- Wenxi Gu
- APHP/Sorbonne Université, GHU Pitié-Salpêtrière, Service ORL, Unité Fonctionnelle Implants Auditifs Et Explorations Fonctionnelles, 50-52 Boulevard Vincent Auriol, 75013, Paris, France
- Institut Pasteur/Université Paris Cité/Inserm, Institut de L'Audition, Technologie Et Thérapie Génique Pour La Surdité, 63 Rue de Charenton, 75012, Paris, France
- Department of Otolaryngology-Head and Neck Surgery, Shanghai Key Laboratory of Translational Medicine On Ear and Nose Diseases (14DZ2260300), Shanghai Ninth People's Hospital, Shanghai Jiao Tong University School of Medicine, Shanghai, China
| | - Hannah Daoudi
- APHP/Sorbonne Université, GHU Pitié-Salpêtrière, Service ORL, Unité Fonctionnelle Implants Auditifs Et Explorations Fonctionnelles, 50-52 Boulevard Vincent Auriol, 75013, Paris, France
- Institut Pasteur/Université Paris Cité/Inserm, Institut de L'Audition, Technologie Et Thérapie Génique Pour La Surdité, 63 Rue de Charenton, 75012, Paris, France
| | - Ghizlene Lahlou
- APHP/Sorbonne Université, GHU Pitié-Salpêtrière, Service ORL, Unité Fonctionnelle Implants Auditifs Et Explorations Fonctionnelles, 50-52 Boulevard Vincent Auriol, 75013, Paris, France
- Institut Pasteur/Université Paris Cité/Inserm, Institut de L'Audition, Technologie Et Thérapie Génique Pour La Surdité, 63 Rue de Charenton, 75012, Paris, France
| | - Olivier Sterkers
- APHP/Sorbonne Université, GHU Pitié-Salpêtrière, Service ORL, Unité Fonctionnelle Implants Auditifs Et Explorations Fonctionnelles, 50-52 Boulevard Vincent Auriol, 75013, Paris, France
- Institut Pasteur/Université Paris Cité/Inserm, Institut de L'Audition, Technologie Et Thérapie Génique Pour La Surdité, 63 Rue de Charenton, 75012, Paris, France
| | - Evelyne Ferrary
- APHP/Sorbonne Université, GHU Pitié-Salpêtrière, Service ORL, Unité Fonctionnelle Implants Auditifs Et Explorations Fonctionnelles, 50-52 Boulevard Vincent Auriol, 75013, Paris, France
- Institut Pasteur/Université Paris Cité/Inserm, Institut de L'Audition, Technologie Et Thérapie Génique Pour La Surdité, 63 Rue de Charenton, 75012, Paris, France
| | - Yann Nguyen
- APHP/Sorbonne Université, GHU Pitié-Salpêtrière, Service ORL, Unité Fonctionnelle Implants Auditifs Et Explorations Fonctionnelles, 50-52 Boulevard Vincent Auriol, 75013, Paris, France
- Institut Pasteur/Université Paris Cité/Inserm, Institut de L'Audition, Technologie Et Thérapie Génique Pour La Surdité, 63 Rue de Charenton, 75012, Paris, France
| | - Isabelle Mosnier
- APHP/Sorbonne Université, GHU Pitié-Salpêtrière, Service ORL, Unité Fonctionnelle Implants Auditifs Et Explorations Fonctionnelles, 50-52 Boulevard Vincent Auriol, 75013, Paris, France
- Institut Pasteur/Université Paris Cité/Inserm, Institut de L'Audition, Technologie Et Thérapie Génique Pour La Surdité, 63 Rue de Charenton, 75012, Paris, France
| | - Renato Torres
- APHP/Sorbonne Université, GHU Pitié-Salpêtrière, Service ORL, Unité Fonctionnelle Implants Auditifs Et Explorations Fonctionnelles, 50-52 Boulevard Vincent Auriol, 75013, Paris, France.
- Institut Pasteur/Université Paris Cité/Inserm, Institut de L'Audition, Technologie Et Thérapie Génique Pour La Surdité, 63 Rue de Charenton, 75012, Paris, France.
- Departamento de Ciencias Fisiológicas, Facultad de Medicina, Universidad Nacional de San Agustín de Arequipa, Arequipa, Peru.
| |
Collapse
|
15
|
Ding L, Zhang L, Li J, Lin T. Electrode-Modiolus Distance Affects Speech Perception for Lateral Wall Electrodes. Otol Neurotol 2023; 44:e702-e709. [PMID: 37939358 DOI: 10.1097/mao.0000000000004019] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/10/2023]
Abstract
OBJECTIVES The goal of this study was to use cone-beam computed tomography to locate the electrode-modiolus distance (EMD) and correlate this with speech perception in cochlear implant (CI) recipients of the 31.5-mm lateral wall (LW) electrode arrays. STUDY DESIGN Retrospective review. PATIENTS Forty-five child CI recipients with prelingual profound sensorineural hearing loss of inserted 31.5-mm LW arrays listening with a CI-alone device. INTERVENTIONS Stepwise forward multiple linear regression was performed to control and reduce the variability in implant performance to determine whether EMD affects speech perception. MAIN OUTCOME MEASURES Electrode location (angular insertion depth [AID], EMD), together with the electrode impedance (EI), surgical approach, sex, CI age, and preimplant hearing aid usage were estimated as independent variables. The dependent variables were the Meaningful Use of Speech Scale (MUSS) and parents' evaluation of children's aural/oral performance (PEACH) assessed with the CI alone at 12 months postactivation. RESULTS EMD and CI age were predictive variables for PEACH/MUSS. A negative correlation was found between AID and EMD (r = -0.56, p < 0.01), whereas EMD had a moderately positive correlation with EI (r = 0.32, p < 0.01). CONCLUSIONS The best "location-related" predictor of postoperative speech perception was EMD with a 31.5-mm array among CI-alone users.
Collapse
Affiliation(s)
- Ling Ding
- Department of Otorhinolaryngology-Head and Neck Surgery, Shandong Provincial Hospital Affiliated to Shandong First Medical University, Jinan, China
| | - Luguang Zhang
- Department of Medical Imaging, The Provincial Hospital Affiliated to Shandong First Medical University, Jinan, China
| | - Jing Li
- Department of Otorhinolaryngology-Head and Neck Surgery, Shandong Provincial Hospital Affiliated to Shandong First Medical University, Jinan, China
| | - Tao Lin
- Department of Neurosurgery, Shandong Second Provincial General Hospital, Jinan, Shandong, 250022, China
| |
Collapse
|
16
|
Aljazeeri I, Alturaiki S, Abdelsamad Y, Alzhrani F, Hagr A. Various approaches to the round window for cochlear implantation: a systematic review. J Laryngol Otol 2023; 137:1064-1082. [PMID: 35729690 DOI: 10.1017/s0022215122001438] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/06/2022]
Abstract
OBJECTIVE Round window approaches are used to insert a cochlear implant electrode array into the scala tympani. This study aimed to review the literature to find the reported round window approaches. METHOD This review was performed according to the Preferred Reporting Items for Systematic Review and Meta-Analyses ('PRISMA') guidelines. Articles that described their surgical approach to the round window were included. The PubMed, Scopus, Web of Science and Cochrane Library electronic databases were searched through to June 2021. The study protocol was registered on Prospero (reference number: CRD42021226940). RESULTS A total of 42 reports were included. The following approaches were documented: the standard facial recess, keyhole, retrofacial, modified suprameatal, transaditus, combined posterior tympanotomy and endomeatal, modified Veria, canal wall down approaches, and endoscopically assisted technique. CONCLUSION This review suggested that there are numerous distinct round window approaches, providing alternatives when the round window is inaccessible through the standard facial recess.
Collapse
Affiliation(s)
- I Aljazeeri
- Aljaber Ophthalmology and Otolaryngology Specialized Hospital, Ministry of Health, Ahsa, Saudi Arabia
- King Abdullah Ear Specialist Center, College of Medicine, King Saud University Medical City, King Saud University, Riyadh, Saudi Arabia
| | - S Alturaiki
- Aljaber Ophthalmology and Otolaryngology Specialized Hospital, Ministry of Health, Ahsa, Saudi Arabia
| | - Y Abdelsamad
- Research Department, MED-EL GmbH, Riyadh, Saudi Arabia
| | - F Alzhrani
- King Abdullah Ear Specialist Center, College of Medicine, King Saud University Medical City, King Saud University, Riyadh, Saudi Arabia
| | - A Hagr
- King Abdullah Ear Specialist Center, College of Medicine, King Saud University Medical City, King Saud University, Riyadh, Saudi Arabia
| |
Collapse
|
17
|
Lindquist NR, Dietrich MS, Patro A, Henry MR, DeFreese AJ, Freeman MH, Perkins EL, Gifford RH, Haynes DS, Holder JT. Early Datalogging Predicts Cochlear Implant Performance: Building a Recommendation for Daily Device Usage. Otol Neurotol 2023; 44:e479-e485. [PMID: 37442607 PMCID: PMC10361622 DOI: 10.1097/mao.0000000000003917] [Citation(s) in RCA: 7] [Impact Index Per Article: 3.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 07/15/2023]
Abstract
OBJECTIVE To quantify the effect of datalogging on speech recognition scores and time to achievement for a "benchmark" level of performance within the first year, and to provide a data-driven recommendation for minimum daily cochlear implant (CI) device usage to better guide patient counseling and future outcomes. STUDY DESIGN Retrospective cohort. SETTING Tertiary referral center. PATIENTS Three hundred thirty-seven adult CI patients with data logging and speech recognition outcome data who were implanted between August 2015 and August 2020. MAIN OUTCOME MEASURES Processor datalogging, speech recognition scores, achievement of "benchmark speech recognition performance" defined as 80% of the median score for speech recognition outcomes at our institution. RESULTS The 1-month datalogging measure correlated positively with word and sentences scores at 1, 3, 6, and 12 months postactivation. Compared with age, sex, and preoperative performance, datalogging was the largest predictive factor of benchmark achievement on multivariate analysis. Each hour/day increase of device usage at 1 month resulted in a higher likelihood of achieving benchmark consonant-nucleus-consonant and AzBio scores within the first year (odds ratio = 1.21, p < 0.001) as well as earlier benchmark achievement. Receiver operating characteristic curve analysis identified the optimal data logging threshold at an average of 12 hours/day. CONCLUSIONS Early CI device usage, as measured by 1-month datalogging, predicts benchmark speech recognition achievement in adults. Datalogging is an important predictor of CI performance within the first year postimplantation. These data support the recommended daily CI processor utilization of at least 12 hours/day to achieve optimal speech recognition performance for most patients.
Collapse
Affiliation(s)
- Nathan R Lindquist
- Department of Otolaryngology-Head and Neck Surgery, Vanderbilt University Medical Center, Nashville, Tennessee
| | - Mary S Dietrich
- Vanderbilt University Schools of Medicine (Biostatistics, VICC, Psychiatry) and Nursing, Nashville, Tennessee
| | - Ankita Patro
- Department of Otolaryngology-Head and Neck Surgery, Vanderbilt University Medical Center, Nashville, Tennessee
| | - Melissa R Henry
- Division of Audiology, Henry Ford Health, Dearborn, Michigan
| | - Andrea J DeFreese
- Department of Hearing and Speech Sciences, Vanderbilt Bill Wilkerson Center, Vanderbilt University Medical Center, Nashville, Tennessee
| | - Michael H Freeman
- Department of Otolaryngology-Head and Neck Surgery, Vanderbilt University Medical Center, Nashville, Tennessee
| | - Elizabeth L Perkins
- Department of Otolaryngology-Head and Neck Surgery, Vanderbilt University Medical Center, Nashville, Tennessee
| | - René H Gifford
- Department of Hearing and Speech Sciences, Vanderbilt Bill Wilkerson Center, Vanderbilt University Medical Center, Nashville, Tennessee
| | - David S Haynes
- Department of Otolaryngology-Head and Neck Surgery, Vanderbilt University Medical Center, Nashville, Tennessee
| | - Jourdan T Holder
- Department of Hearing and Speech Sciences, Vanderbilt Bill Wilkerson Center, Vanderbilt University Medical Center, Nashville, Tennessee
| |
Collapse
|
18
|
Hrncirik F, Roberts I, Sevgili I, Swords C, Bance M. Models of Cochlea Used in Cochlear Implant Research: A Review. Ann Biomed Eng 2023; 51:1390-1407. [PMID: 37087541 PMCID: PMC10264527 DOI: 10.1007/s10439-023-03192-3] [Citation(s) in RCA: 2] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/13/2023] [Accepted: 03/20/2023] [Indexed: 04/24/2023]
Abstract
As the first clinically translated machine-neural interface, cochlear implants (CI) have demonstrated much success in providing hearing to those with severe to profound hearing loss. Despite their clinical effectiveness, key drawbacks such as hearing damage, partly from insertion forces that arise during implantation, and current spread, which limits focussing ability, prevent wider CI eligibility. In this review, we provide an overview of the anatomical and physical properties of the cochlea as a resource to aid the development of accurate models to improve future CI treatments. We highlight the advancements in the development of various physical, animal, tissue engineering, and computational models of the cochlea and the need for such models, challenges in their use, and a perspective on their future directions.
Collapse
Affiliation(s)
- Filip Hrncirik
- Cambridge Hearing Group, Cambridge, UK.
- Department of Clinical Neurosciences, University of Cambridge, Cambridge, CB2 0QQ, UK.
| | - Iwan Roberts
- Cambridge Hearing Group, Cambridge, UK
- Department of Clinical Neurosciences, University of Cambridge, Cambridge, CB2 0QQ, UK
| | - Ilkem Sevgili
- Cambridge Hearing Group, Cambridge, UK
- Department of Clinical Neurosciences, University of Cambridge, Cambridge, CB2 0QQ, UK
| | - Chloe Swords
- Cambridge Hearing Group, Cambridge, UK
- Department of Physiology, Development and Neurosciences, University of Cambridge, Cambridge, CB2 3DY, UK
| | - Manohar Bance
- Cambridge Hearing Group, Cambridge, UK
- Department of Clinical Neurosciences, University of Cambridge, Cambridge, CB2 0QQ, UK
| |
Collapse
|
19
|
Castle N, Liang J, Smith M, Petersen B, Matson C, Eldridge T, Zhang K, Lee CH, Liu Y, Dai C. Finite Element Modeling of Residual Hearing after Cochlear Implant Surgery in Chinchillas. Bioengineering (Basel) 2023; 10:bioengineering10050539. [PMID: 37237608 DOI: 10.3390/bioengineering10050539] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/28/2023] [Revised: 04/20/2023] [Accepted: 04/24/2023] [Indexed: 05/28/2023] Open
Abstract
Cochlear implant (CI) surgery is one of the most utilized treatments for severe hearing loss. However, the effects of a successful scala tympani insertion on the mechanics of hearing are not yet fully understood. This paper presents a finite element (FE) model of the chinchilla inner ear for studying the interrelationship between the mechanical function and the insertion angle of a CI electrode. This FE model includes a three-chambered cochlea and full vestibular system, accomplished using µ-MRI and µ-CT scanning technologies. This model's first application found minimal loss of residual hearing due to insertion angle after CI surgery, and this indicates that it is a reliable and helpful tool for future applications in CI design, surgical planning, and stimuli setup.
Collapse
Affiliation(s)
- Nicholas Castle
- Department of Aerospace and Mechanical Engineering, University of Oklahoma, Norman, OK 73019, USA
| | - Junfeng Liang
- Department of Aerospace and Mechanical Engineering, University of Oklahoma, Norman, OK 73019, USA
| | - Matthew Smith
- Department of Aerospace and Mechanical Engineering, University of Oklahoma, Norman, OK 73019, USA
| | - Brett Petersen
- Department of Aerospace and Mechanical Engineering, University of Oklahoma, Norman, OK 73019, USA
| | - Cayman Matson
- Department of Aerospace and Mechanical Engineering, University of Oklahoma, Norman, OK 73019, USA
| | - Tara Eldridge
- Department of Aerospace and Mechanical Engineering, University of Oklahoma, Norman, OK 73019, USA
| | - Ke Zhang
- Department of Aerospace and Mechanical Engineering, University of Oklahoma, Norman, OK 73019, USA
| | - Chung-Hao Lee
- Department of Aerospace and Mechanical Engineering, University of Oklahoma, Norman, OK 73019, USA
| | - Yingtao Liu
- Department of Aerospace and Mechanical Engineering, University of Oklahoma, Norman, OK 73019, USA
| | - Chenkai Dai
- Department of Aerospace and Mechanical Engineering, University of Oklahoma, Norman, OK 73019, USA
| |
Collapse
|
20
|
Robotized Cochlear Implantation under Fluoroscopy: A Preliminary Series. J Clin Med 2022; 12:jcm12010211. [PMID: 36615012 PMCID: PMC9820833 DOI: 10.3390/jcm12010211] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/29/2022] [Revised: 12/23/2022] [Accepted: 12/24/2022] [Indexed: 12/29/2022] Open
Abstract
It is known that visual feedback by fluoroscopy can detect electrode array (EA) misrouting within the cochlea while robotized EA-insertion (rob-EAI) permits atraumatic cochlear implantation. We report here our unique experience of both fluoroscopy feedback and rob-EAI in cochlear implant surgery. We retrospectively analyzed a cohort of consecutive patients implanted from November 2021−October 2022 using rob-EAI, with the RobOtol®, to determine the quality of EA-insertion and the additional time required. Twenty-three patients (10 females, 61+/−19 yo) were tentatively implanted using robot assistance, with a rob-EAI speed < 1 mm/s. Only three cases required a successful revised insertion by hand. Under fluoroscopy (n = 11), it was possible to achieve a remote rob-EAI (n = 8), as the surgeon was outside the operative room, behind an anti-radiation screen. No scala translocation occurred. The additional operative time due to robot use was 18+/−7 min with about 4 min more for remote rob-EAI. Basal cochlear turn fibrosis precluded rob-EAI. In conclusion, Rob-EAI can be performed in almost all cases with a low risk of scala translocation, except in the case of partial cochlear obstruction such as fibrosis. Fluoroscopy also permits remote rob-EAI.
Collapse
|
21
|
Sharma RK, Smetak MR, Patro A, Lindquist NR, Perkins EL, Holder JT, Haynes DS, Tawfik KO. Speech Recognition Performance Differences Between Precurved and Straight Electrode Arrays From a Single Manufacturer. Otol Neurotol 2022; 43:1149-1154. [PMID: 36201525 DOI: 10.1097/mao.0000000000003703] [Citation(s) in RCA: 6] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/26/2022]
Abstract
OBJECTIVE Precurved cochlear implant (CI) electrode arrays have demonstrated superior audiometric outcomes compared with straight electrodes in a handful of studies. However, previous comparisons have often failed to account for preoperative hearing and age. This study compares hearing outcomes for precurved and straight electrodes by a single manufacturer while controlling for these and other factors in a large cohort. STUDY DESIGN Retrospective cohort study. SETTING Tertiary academic medical center. PATIENTS Two hundred thirty-one adult CI recipients between 2015 and 2021 with cochlear (Sydney, Australia) 522/622 (straight) or 532/632 (precurved) electrode arrays. INTERVENTIONS Postactivation speech recognition and audiometric testing. MAIN OUTCOME MEASURES Speech recognition testing (consonant-nucleus-consonant word [CNCw] and AzBio) was collected at 6 and 12 months postactivation. Hearing preservation was characterized by a low-frequency pure-tone average shift, or the change between preoperative and postoperative low-frequency pure-tone average. RESULTS Two hundred thirty-one patients (253 ears) with 6-month and/or 12-month CNCw or AzBio testing were included. One hundred forty-nine (59%) and 104 (41%) ears were implanted with straight and precurved electrode arrays, respectively. Average age at implantation was 70 years (interquartile range [IQR], 58-77 y). There was no significant difference in mean age between groups. CNCw scores were significantly different ( p = 0.001) between straight (51%; IQR, 36-67%) and precurved arrays (64%; IQR, 48-72%). AzBio scores were not significantly different ( p = 0.081) between straight (72%; IQR, 51-87%) and precurved arrays (81%; IQR, 57-90%). Controlling for age, race, sex, preoperative hearing, and follow-up time, precurved electrode arrays performed significantly better on CNCw (b = 10.0; 95% confidence interval, 4.2-16.0; p < 0.001) and AzBio (b = 8.9; 95% confidence interval, 1.8-16.0;, p = 0.014) testing. Hearing preservation was not different between electrodes on adjusted models. CONCLUSION During the study period, patients undergoing placement of precurved electrode arrays had significantly higher CNC and AzBio scores than patients receiving straight electrodes, even after controlling for age, preoperative hearing, and follow-up time. PROFESSIONAL PRACTICE GAP AND EDUCATIONAL NEED Understanding the difference in audiometric outcomes between precurved and straight electrode arrays will help to guide electrode selection. LEARNING OBJECTIVE To understand differences in speech recognition scores postoperatively by electrode array type (precurved versus straight). DESIRED RESULT To demonstrate a difference in hearing performance postoperatively by electrode type. LEVEL OF EVIDENCE III. INDICATE IRB OR IACUC Approved by the Institutional IRB (090155).
Collapse
Affiliation(s)
- Rahul K Sharma
- Department of Otolaryngology-Head & Neck Surgery, Vanderbilt University Medical Center
| | - Miriam R Smetak
- Department of Otolaryngology-Head & Neck Surgery, Vanderbilt University Medical Center
| | - Ankita Patro
- Department of Otolaryngology-Head & Neck Surgery, Vanderbilt University Medical Center
| | - Nathan R Lindquist
- Department of Otolaryngology-Head & Neck Surgery, Vanderbilt University Medical Center
| | - Elizabeth L Perkins
- Department of Otolaryngology-Head & Neck Surgery, Vanderbilt University Medical Center
| | | | - David S Haynes
- Department of Otolaryngology-Head & Neck Surgery, Vanderbilt University Medical Center
| | - Kareem O Tawfik
- Department of Otolaryngology-Head & Neck Surgery, Vanderbilt University Medical Center
| |
Collapse
|
22
|
The effect of the surgical approach and cochlear implant electrode on the structural integrity of the cochlea in human temporal bones. Sci Rep 2022; 12:17068. [PMID: 36224234 PMCID: PMC9556579 DOI: 10.1038/s41598-022-21399-7] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/19/2022] [Accepted: 09/27/2022] [Indexed: 12/30/2022] Open
Abstract
Cochlear implants (CI) restore hearing of severely hearing-impaired patients. Although this auditory prosthesis is widely considered to be very successful, structural cochlear trauma during cochlear implantation is an important problem, reductions of which could help to improve hearing outcomes and to broaden selection criteria. The surgical approach in cochlear implantation, i.e. round window (RW) or cochleostomy (CO), and type of electrode-array, perimodiolar (PM) or lateral wall (LW), are variables that might influence the probability of severe trauma. We investigated the effect of these two variables on scalar translocation (STL), a specific type of severe trauma. Thirty-two fresh frozen human cadaveric ears were evenly distributed over four groups receiving either RW or CO approach, and either LW or PM array. Conventional radiological multiplanar reconstruction (MPR) was compared with a reconstruction method that uncoils the spiral shape of the cochlea (UCR). Histological analysis showed that RW with PM array had STL rate of 87% (7/8), CO approach with LW array 75% (6/8), RW approach with LW array 50% (4/8) and CO approach with PM array 29% (2/7). STL assessment using UCR showed a higher inter-observer and histological agreement (91 and 94% respectively), than that using MPR (69 and 74% respectively). In particular, LW array positions were difficult to assess with MPR. In conclusion, the interaction between surgical approach and type of array should be preoperatively considered in cochlear implant surgery. UCR technique is advised for radiological assessment of CI positions, and in general it might be useful for pathologies involving the inner ear or other complex shaped bony tubular structures.
Collapse
|
23
|
Reiss LA, Kirk J, Claussen AD, Fallon JB. Animal Models of Hearing Loss after Cochlear Implantation and Electrical Stimulation. Hear Res 2022; 426:108624. [DOI: 10.1016/j.heares.2022.108624] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 09/24/2021] [Revised: 03/28/2022] [Accepted: 09/23/2022] [Indexed: 11/04/2022]
|
24
|
Rahman MT, Chari DA, Ishiyama G, Lopez I, Quesnel AM, Ishiyama A, Nadol JB, Hansen MR. Cochlear implants: Causes, effects and mitigation strategies for the foreign body response and inflammation. Hear Res 2022; 422:108536. [PMID: 35709579 PMCID: PMC9684357 DOI: 10.1016/j.heares.2022.108536] [Citation(s) in RCA: 25] [Impact Index Per Article: 8.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 09/20/2021] [Revised: 04/20/2022] [Accepted: 05/23/2022] [Indexed: 12/15/2022]
Abstract
Cochlear implants provide effective auditory rehabilitation for patients with severe to profound sensorineural hearing loss. Recent advances in cochlear implant technology and surgical approaches have enabled a greater number of patients to benefit from this technology, including those with significant residual low frequency acoustic hearing. Nearly all cochleae implanted with a cochlear implant electrode array develop an inflammatory and fibrotic response. This tissue reaction can have deleterious consequences for implant function, residual acoustic hearing, and the development of the next generation of cochlear prosthetics. This article reviews the current understanding of the inflammatory/foreign body response (FBR) after cochlear implant surgery, its impact on clinical outcome, and therapeutic strategies to mitigate this response. Findings from both in human subjects and animal models across a variety of species are highlighted. Electrode array design, surgical techniques, implant materials, and the degree and type of electrical stimulation are some critical factors that affect the FBR and inflammation. Modification of these factors and various anti-inflammatory pharmacological interventions have been shown to mitigate the inflammatory/FBR response. Ongoing and future approaches that seek to limit surgical trauma and curb the FBR to the implanted biomaterials of the electrode array are discussed. A better understanding of the anatomical, cellular and molecular basis of the inflammatory/FBR response after cochlear implantation has the potential to improve the outcome of current cochlear implants and also facilitate the development of the next generation of neural prostheses.
Collapse
Affiliation(s)
- Muhammad T Rahman
- Department of Otolaryngology-Head & Neck Surgery, University of Iowa, Iowa City, IA, USA
| | - Divya A Chari
- Department of Otolaryngology-Head & Neck Surgery, Harvard University, Boston, MA, USA
| | - Gail Ishiyama
- Department of Head & Neck Surgery, University of California Los Angeles, LA, USA
| | - Ivan Lopez
- Department of Head & Neck Surgery, University of California Los Angeles, LA, USA
| | - Alicia M Quesnel
- Department of Otolaryngology-Head & Neck Surgery, Harvard University, Boston, MA, USA
| | - Akira Ishiyama
- Department of Head & Neck Surgery, University of California Los Angeles, LA, USA
| | - Joseph B Nadol
- Department of Otolaryngology-Head & Neck Surgery, Harvard University, Boston, MA, USA
| | - Marlan R Hansen
- Department of Otolaryngology-Head & Neck Surgery, University of Iowa, Iowa City, IA, USA.
| |
Collapse
|
25
|
Perkins EL, Labadie RF, O’Malley M, Bennett M, Noble JH, Haynes DS, Gifford R. The Relation of Cochlear Implant Electrode Array Type and Position on Continued Hearing Preservation. Otol Neurotol 2022; 43:e634-e640. [PMID: 35709407 PMCID: PMC9824900 DOI: 10.1097/mao.0000000000003547] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/03/2023]
Abstract
OBJECTIVE To analyze the relationship of electrode array (EA) type and position on hearing preservation longevity following cochlear implantation. STUDY DESIGN Retrospective chart review. SETTING Tertiary referral center. PATIENTS Adult cochlear implant recipients between 2013 and 2019 with hearing preserved postoperatively and postoperative CT scans. INTERVENTIONS CT scan analysis of EA position. Stepwise regression to determine influence of EA position, EA type, and patient demographics on postoperative low frequency hearing. MAIN OUTCOME MEASURES Low frequency pure tone average (LFPTA), LFPTA shift, angular insertion depth, base insertion depth, scalar position, mean perimodiolar distance. RESULTS Of 792 cochlear implant recipients, 121 had preoperative LFPTA <80 dB HL with 60 of the 121 (49.6%) implanted with straight, 32 (26.4%) with precurved, styletted, and 29 (24.0%) implanted precurved, nonstyletted EA. Mean follow up was 28.6 months (range 1-103). There was no statistically significant difference in activation, 6- and 12-month, and last follow-up LFPTA (125, 250, and 500 Hz) shift based on EA type (straight p = 0.302, precurved, styletted p = 0.52, precurved, nonstyletted p = 0.77). Preoperative LFPTA and age of implantation were significant predictors of LFPTA shift at activation, accounting for 30.8% of variance ( F [2, 113] = 26.603, p < 0.0001). LFPTA shift at activation, scalar position, and base insertion depth were significant predictors of variability and accounted for 39.1% of variance in LFPTA shift at 6 months ( F [3, 87] = 20.269, p < 0.0001). Only LFPTA shift at 12 months was found to be a significant predictor of LFPTA shift at last follow up, accounting for 41.0% of variance ( F [1, 48] = 32.653, p < 0.0001). CONCLUSIONS Patients had excellent long-term residual hearing regardless of EA type. Age, preoperative acoustic hearing, and base insertion depth may predict short term preservation, while 12-month outcomes significantly predicted long-term hearing preservation.
Collapse
Affiliation(s)
- Elizabeth L. Perkins
- Department of Otolaryngology – Head and Neck Surgery, Vanderbilt University Medical Center, Nashville, Tennessee
| | - Robert F. Labadie
- Department of Otolarynology – Head and Neck Surgery, Medical University of South Carolina, Charleston, South Carolina
| | - Matthew O’Malley
- Department of Otolaryngology – Head and Neck Surgery, Vanderbilt University Medical Center, Nashville, Tennessee
| | - Marc Bennett
- Department of Otolaryngology – Head and Neck Surgery, Vanderbilt University Medical Center, Nashville, Tennessee
| | - Jack H. Noble
- Department of Electrical Engineering and Computer Science, Vanderbilt University, Vanderbilt Bill Wilkerson Center, Department of Hearing and Speech Sciences, Nashville, Tennessee
| | - David S. Haynes
- Department of Otolaryngology – Head and Neck Surgery, Vanderbilt University Medical Center, Nashville, Tennessee
| | - René Gifford
- Department of Otolaryngology – Head and Neck Surgery, Vanderbilt University Medical Center, Nashville, Tennessee
| |
Collapse
|
26
|
Real-Time Data-Driven Approach for Prediction and Correction of Electrode Array Trajectory in Cochlear Implantation. APPLIED SCIENCES-BASEL 2022. [DOI: 10.3390/app12136343] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 12/21/2022]
Abstract
Cochlear implants provide hearing perception to people with severe to profound hearing loss. The electrode array (EA) inserted during the surgery directly stimulates the hearing nerve, bypassing the acoustic hearing system. The complications during the EA insertion in the inner ear may cause trauma leading to infection, residual hearing loss, and poor speech perception. This work aims to reduce the trauma induced during electrode array insertion process by carefully designing a sensing method, an actuation system, and data-driven control strategy to guide electrode array in scala tympani. Due to limited intra-operative feedback during the insertion process, complex bipolar electrical impedance is used as a sensing element to guide EA in real time. An automated actuation system with three degrees of freedom was used along with a complex impedance meter to record impedance of consecutive electrodes. Prediction of EA direction (medial, middle, and lateral) was carried out by an ensemble of random forest, shallow neural network, and k-nearest neighbour in an offline setting with an accuracy of 86.86%. The trained ensemble was then utilized in vitro for prediction and correction of EA direction in real time in the straight path with an accuracy of 80%. Such a real-time system also has application in other electrode implants and needle and catheter insertion guidance.
Collapse
|
27
|
Leblans M, Sismono F, Vanpoucke F, van Dinther J, Lerut B, Kuhweide R, Offeciers E, Zarowski A. Novel Impedance Measures as Biomarker for Intracochlear Fibrosis. Hear Res 2022; 426:108563. [DOI: 10.1016/j.heares.2022.108563] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 10/29/2021] [Revised: 04/05/2022] [Accepted: 06/15/2022] [Indexed: 11/04/2022]
|
28
|
Best Fit 3D Basilar Membrane Reconstruction to Routinely Assess the Scalar Position of the Electrode Array after Cochlear Implantation. J Clin Med 2022; 11:jcm11082075. [PMID: 35456169 PMCID: PMC9030636 DOI: 10.3390/jcm11082075] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/24/2022] [Revised: 04/03/2022] [Accepted: 04/05/2022] [Indexed: 12/04/2022] Open
Abstract
The scalar position of the electrode array is assumed to be associated with auditory performance after cochlear implantation. We propose a new method that can be routinely applied in clinical practice to assess the position of an electrode array. Ten basilar membrane templates were generated using micro-computed tomography (micro-CT), based on the dimensions of 100 cochleae. Five surgeons were blinded to determine the position of the electrode array in 30 cadaveric cochleae. The procedure consisted of selecting the appropriate template based on cochlear dimensions, merging the electrode array reconstruction with the template using four landmarks, determining the position of the array according to the template position, and comparing the results obtained to histology data. The time taken to analyze each implanted cochlea was approximately 12 min. We found that, according to histology, surgeons were in almost perfect agreement when determining an electrode translocated to the scala vestibuli with the perimodiolar MidScala array (Fleiss’ kappa (κ) = 0.82), and in moderate agreement when using the lateral wall EVO array (κ = 0.42). Our data indicate that an adapted basilar membrane template can be used as a rapid and reproducible method to assess the position of the electrode array after cochlear implantation.
Collapse
|
29
|
Van de Heyning P, Roland P, Lassaletta L, Agrawal S, Atlas M, Baumgartner WD, Brown K, Caversaccio M, Dazert S, Gstoettner W, Hagen R, Hagr A, Jablonski GE, Kameswaran M, Kuzovkov V, Leinung M, Li Y, Loth A, Magele A, Mlynski R, Mueller J, Parnes L, Radeloff A, Raine C, Rajan G, Schmutzhard J, Skarzynski H, Skarzynski PH, Sprinzl G, Staecker H, Stöver T, Tavora-Viera D, Topsakal V, Usami SI, Van Rompaey V, Weiss NM, Wimmer W, Zernotti M, Gavilan J. Suitable Electrode Choice for Robotic-Assisted Cochlear Implant Surgery: A Systematic Literature Review of Manual Electrode Insertion Adverse Events. Front Surg 2022; 9:823219. [PMID: 35402479 PMCID: PMC8987358 DOI: 10.3389/fsurg.2022.823219] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/26/2021] [Accepted: 02/09/2022] [Indexed: 12/05/2022] Open
Abstract
Background and Objective The cochlear implant (CI) electrode insertion process is a key step in CI surgery. One of the aims of advances in robotic-assisted CI surgery (RACIS) is to realize better cochlear structure preservation and to precisely control insertion. The aim of this literature review is to gain insight into electrode selection for RACIS by acquiring a thorough knowledge of electrode insertion and related complications from classic CI surgery involving a manual electrode insertion process. Methods A systematic electronic search of the literature was carried out using PubMed, Scopus, Cochrane, and Web of Science to find relevant literature on electrode tip fold over (ETFO), electrode scalar deviation (ESD), and electrode migration (EM) from both pre-shaped and straight electrode types. Results A total of 82 studies that include 8,603 ears implanted with a CI, i.e., pre-shaped (4,869) and straight electrodes (3,734), were evaluated. The rate of ETFO (25 studies, 2,335 ears), ESD (39 studies, 3,073 ears), and EM (18 studies, 3,195 ears) was determined. An incidence rate (±95% CI) of 5.38% (4.4-6.6%) of ETFO, 28.6% (26.6-30.6%) of ESD, and 0.53% (0.2-1.1%) of EM is associated with pre-shaped electrodes, whereas with straight electrodes it was 0.51% (0.1-1.3%), 11% (9.2-13.0%), and 3.2% (2.5-3.95%), respectively. The differences between the pre-shaped and straight electrode types are highly significant (p < 0.001). Laboratory experiments show evidence that robotic insertions of electrodes are less traumatic than manual insertions. The influence of round window (RW) vs. cochleostomy (Coch) was not assessed. Conclusion Considering the current electrode designs available and the reported incidence of insertion complications, the use of straight electrodes in RACIS and conventional CI surgery (and manual insertion) appears to be less traumatic to intracochlear structures compared with pre-shaped electrodes. However, EM of straight electrodes should be anticipated. RACIS has the potential to reduce these complications.
Collapse
Affiliation(s)
- Paul Van de Heyning
- Department of Otorhinolaryngology Head and Neck Surgery, Antwerp University Hospital, University of Antwerp, Antwerp, Belgium
- Department of Translational Neurosciences, University of Antwerp, Antwerp, Belgium
| | - Peter Roland
- Department of Otolaryngology, Head & Neck Surgery, University of Texas Southwestern Medical Center, Dallas, TX, United States
| | - Luis Lassaletta
- Hospital Universitario La Paz, Institute for Health Research (IdiPAZ), Madrid, Spain
| | - Sumit Agrawal
- Department of Otolaryngology-Head and Neck Surgery, Western University, London, ON, Canada
| | - Marcus Atlas
- Ear Sciences Institute Australia, Lions Hearing Clinic, Perth, WA, Australia
| | | | - Kevin Brown
- UNC Ear and Hearing Center at Chapel Hill School of Medicine, Chapel Hill, NC, United States
| | - Marco Caversaccio
- Department for ENT, Head and Neck Surgery, Bern University Hospital, Bern, Switzerland
| | - Stefan Dazert
- Department of Otorhinolaryngology-Head and Neck Surgery, Ruhr-University Bochum, St. Elisabeth University Hospital Bochum, Bochum, Germany
| | | | - Rudolf Hagen
- Würzburg ENT University Hospital, Würzburg, Germany
| | - Abdulrahman Hagr
- King Abdullah Ear Specialist Center, King Saud University Medical City, King Saud University, Riyadh, Saudi Arabia
| | - Greg Eigner Jablonski
- Institute of Clinical Medicine, University of Oslo, Oslo, Norway
- Department of Otorhinolaryngology & Head and Neck Surgery, Oslo University Hospital, Rikshospitalet, Oslo, Norway
| | | | - Vladislav Kuzovkov
- St. Petersburg ENT and Speech Research Institute, St. Petersburg, Russia
| | - Martin Leinung
- Department of Otolaryngology, Head and Neck Surgery, University Hospital Frankfurt, Frankfurt am Main, Germany
| | - Yongxin Li
- Department of Otorhinolaryngology Head and Neck Surgery, Beijing Tongren Hospital, Capital Medical University, Beijing, China
- Key Laboratory of Otolaryngology Head and Neck Surgery (Capital Medical University), Ministry of Education, Beijing, China
| | - Andreas Loth
- Department of Otolaryngology, Head and Neck Surgery, University Hospital Frankfurt, Frankfurt am Main, Germany
| | - Astrid Magele
- Ear, Nose and Throat Department, University Clinic St. Poelten, Karl Landsteiner Private University, St. Poelten, Austria
| | - Robert Mlynski
- Department of Otorhinolaryngology, Head and Neck Surgery, “Otto Körner” Rostock University Medical Center, Rostock, Germany
| | - Joachim Mueller
- Klinik und Poliklinik für Hals-, Nasen- und Ohrenheilkunde, Ludwig-Maximilians-Universitat Munchen, Munchen, Germany
| | - Lorne Parnes
- Department of Otolaryngology-Head and Neck Surgery, Western University, London, ON, Canada
| | - Andreas Radeloff
- Division of Oto-Rhino-Laryngology, Evangelisches Krankenhaus Oldenburg, Research Center of Neurosensory Sciences, University Oldenburg, Oldenburg, Germany
| | - Chris Raine
- Bradford Royal Infirmary Yorkshire Auditory Implant Center, Bradford, United Kingdom
| | - Gunesh Rajan
- Department of Otolaryngology, Head and Neck Surgery, Luzerner Kantonsspital, Luzern, Medical Sciences Department of Health Sciences and Medicine. University of Lucerne, Luzern, Switzerland. Otolaryngology, Head & Neck Surgery, Medical School University of Western Australia, Perth, WA, Australia
| | - Joachim Schmutzhard
- Department of Otorhinolaryngology, Medical University of Innsbruck, Innsbruck, Austria
| | - Henryk Skarzynski
- Department of Teleaudiology and Screening, World Hearing Center of the Institute of Physiology and Pathology of Hearing, Kajetany, Poland
| | - Piotr H. Skarzynski
- Department of Teleaudiology and Screening, World Hearing Center of the Institute of Physiology and Pathology of Hearing, Kajetany, Poland
| | - Georg Sprinzl
- Ear, Nose and Throat Department, University Clinic St. Poelten, Karl Landsteiner Private University, St. Poelten, Austria
| | - Hinrich Staecker
- Kansas University Center for Hearing and Balance Disorders, Kansas City, KS, United States
| | - Timo Stöver
- Department of Otolaryngology, Head and Neck Surgery, University Hospital Frankfurt, Frankfurt am Main, Germany
| | | | - Vedat Topsakal
- Department of ENT HNS, University Hospital Brussels, Brussels, Belgium
| | - Shin-Ichi Usami
- Department of Hearing Implant Sciences, Shinshu University School of Medicine, Nagano, Japan
| | - Vincent Van Rompaey
- Department of Otorhinolaryngology Head and Neck Surgery, Antwerp University Hospital, University of Antwerp, Antwerp, Belgium
- Department of Translational Neurosciences, University of Antwerp, Antwerp, Belgium
| | - Nora M. Weiss
- Department of Otorhinolaryngology-Head and Neck Surgery, Ruhr-University Bochum, St. Elisabeth University Hospital Bochum, Bochum, Germany
| | - Wilhelm Wimmer
- Department for ENT, Head and Neck Surgery, Bern University Hospital, Bern, Switzerland
| | - Mario Zernotti
- Catholic University of Córdoba and National University of Córdoba, Córdoba, Argentina
| | - Javier Gavilan
- Hospital Universitario La Paz, Institute for Health Research (IdiPAZ), Madrid, Spain
| |
Collapse
|
30
|
Intracochlear New Fibro-Ossification and Neuronal Degeneration Following Cochlear Implant Electrode Translocation: Long-Term Histopathological Findings in Humans. Otol Neurotol 2022; 43:e153-e164. [PMID: 35015749 DOI: 10.1097/mao.0000000000003402] [Citation(s) in RCA: 10] [Impact Index Per Article: 3.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/07/2023]
Abstract
OBJECTIVE We aim to assess the histopathology of human temporal bones (TBs) with evidence of cochlear implantation (CI) electrode scalar translocation. STUDY DESIGN Otopathology study. SETTING Otopathology laboratory. PATIENTS TBs from patients who had a history of CI and histopathological evidence of interscalar translocation. Specimens with electrode placed entirely within the ST served as controls. INTERVENTION Histopathological assessment of human TBs. MAIN OUTCOME MEASURES TBs from each patient were harvested postmortem and histologically analyzed for intracochlear changes in the context of CI electrode translocation and compared to controls. Intracochlear new fibro-ossification, and spiral ganglion neuron (SGN) counts were assessed. Postoperative word recognition scores (WRS) were also compared. RESULTS Nineteen human TBs with electrode translocation and eight controls were identified. The most common site of translocation was the ascending limb of the basal turn (n = 14 TBs). The average angle of insertion at the point of translocation was 159° ± 79°. Eighteen translocated cases presented moderate fibroosseous changes in the basal region of the cochlea, extending to the translocation point and/or throughout the electrode track in 42%. Lower SGN counts were more pronounced in translocated cases compared to controls, with a significant difference for segment II (p = 0.019). Although final postoperative hearing outcomes were similar between groups, translocated cases had slower rate of improvement in WRS (p = 0.021). CONCLUSIONS Cochlear implant electrode translocation was associated with greater fibroosseous formation and lower SGN population. Our findings suggest that scalar translocations may slow the rate of improvement in WRS overtime as compared to atraumatic electrode insertions.Level of evidence: IV.
Collapse
|
31
|
Intracochlear electrode array position and cochlear implant outcomes using the nucleus slim modiolar electrode and the extended round window approach: a follow-up study. Eur Arch Otorhinolaryngol 2022; 279:4735-4743. [PMID: 35041067 PMCID: PMC9474433 DOI: 10.1007/s00405-021-07247-w] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/15/2021] [Accepted: 12/28/2021] [Indexed: 01/10/2023]
Abstract
PURPOSE The aim of this study was to evaluate the intracochlear position of the Slim Modiolar Electrode (SME) after insertion via the extended Round Window (eRW) approach, and to correlate this with residual hearing preservation and speech perception outcomes. METHODS Twenty-three adult participants, consecutively implanted with the SME via the eRW approach, were included in this prospective, single-center, observational study. Electrode position was evaluated intra-operatively using X-ray fluoroscopy and TIM measurement, and post-operatively using ultra-high resolution CT. Residual hearing [threshold shift in PTA between pre- and post-operative measurement, relative hearing preservation (RHP%)] and speech perception were evaluated at 2 and 12 months after surgery. RESULTS In each of the 23 participants, complete scala tympani positioning of the electrode array could be achieved. In one participant, an initial tip fold-over was corrected during surgery. Average age at implantation was 63.3 years (SD 13.3, range 28-76) and mean preoperative residual hearing was 81.5 dB. The average post-operative PTA threshold shift was 16.2 dB (SD 10.8) at 2 months post-operatively, corresponding with a RHP% score of 44% (SD 34.9). At 12 months, the average RHP% score decreased to 37%. Postoperative phoneme scores improved from 27.1% preoperatively, to 72.1% and 82.1% at 2 and 12 months after surgery, respectively. CONCLUSION Use of the eRW approach results in an increased likelihood of complete scala tympani insertion when inserting the SME, with subsequent excellent levels of speech perception. However, residual hearing preservation was found to be moderate, possibly as a result of the extended round window approach, emphasizing that it is not an all-purpose approach for inserting this particular electrode array.
Collapse
|
32
|
Jwair S, Boerboom RA, Versnel H, Stokroos RJ, Thomeer HGXM. Evaluating cochlear insertion trauma and hearing preservation after cochlear implantation (CIPRES): a study protocol for a randomized single-blind controlled trial. Trials 2021; 22:895. [PMID: 34886884 PMCID: PMC8656003 DOI: 10.1186/s13063-021-05878-2] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/13/2020] [Accepted: 11/25/2021] [Indexed: 12/26/2022] Open
Abstract
Background In order to preserve residual hearing in patients with sensorineural hearing loss (SNHL) who receive a cochlear implant (CI), insertion trauma to the delicate structures of the cochlea needs to be minimized. The surgical approach comprises the conventional mastoidectomy-posterior tympanotomy (MPT) to arrive at the middle ear, followed by either a cochleostomy (CO) or the round window (RW) approach. Both techniques have their benefits and disadvantages. Another important aspect in structure preservation is the design of the electrode array. Two different designs are used: a “straight” lateral wall lying electrode array (LW) or a “pre-curved” perimodiolar lying electrode array (PM). Interestingly, until now, the best surgical approach and design of the implant is uncertain. Our hypothesis is that there is a difference in hearing preservation outcomes between the four possible treatment options. Methods We designed a monocenter, multi-arm, randomized controlled trial to compare insertion trauma between four groups of patients, with each group having a unique combination of an electrode array type (LW or PM) and surgical approach (RW or CO). In total, 48 patients will be randomized into one of these four intervention groups. Our primary objective is the comparison of postoperative hearing preservation between these four groups. Secondly, we aim to assess structure preservation (i.e., scalar translocation, with basilar membrane disruption or tip fold-over of array) for each group. Thirdly, we will compare objective outcomes of hearing and structure preservation by way of electrocochleography (ECochG). Discussion Cochlear implantation by way of a cochleostomy or round window approach, using different electrode array types, is the standard medical care for patients with severe to profound bilateral sensorineural hearing loss, as it is a relatively simple and low-risk procedure that greatly benefits patients. However, loss of residual hearing remains a problem. This trial is the first randomized controlled trial that evaluates the effect of cochlear insertion trauma of several CI treatment options on hearing preservation. Trial registration Netherlands Trial Register (NTR) NL8586. Registered on 4 May 2020. Retrospectively registered; 3/48 participants were included before registration. Supplementary Information The online version contains supplementary material available at 10.1186/s13063-021-05878-2.
Collapse
Affiliation(s)
- Saad Jwair
- Department of Otorhinolaryngology and Head & Neck Surgery, University Medical Center Utrecht, Utrecht University, P.O. Box 85500, 3508, GA, Utrecht, the Netherlands. .,UMC Utrecht Brain Center, Utrecht University, Utrecht, the Netherlands.
| | - Ralf A Boerboom
- Department of Otorhinolaryngology and Head & Neck Surgery, University Medical Center Utrecht, Utrecht University, P.O. Box 85500, 3508, GA, Utrecht, the Netherlands.,UMC Utrecht Brain Center, Utrecht University, Utrecht, the Netherlands
| | - Huib Versnel
- Department of Otorhinolaryngology and Head & Neck Surgery, University Medical Center Utrecht, Utrecht University, P.O. Box 85500, 3508, GA, Utrecht, the Netherlands.,UMC Utrecht Brain Center, Utrecht University, Utrecht, the Netherlands
| | - Robert J Stokroos
- Department of Otorhinolaryngology and Head & Neck Surgery, University Medical Center Utrecht, Utrecht University, P.O. Box 85500, 3508, GA, Utrecht, the Netherlands.,UMC Utrecht Brain Center, Utrecht University, Utrecht, the Netherlands
| | - Hans G X M Thomeer
- Department of Otorhinolaryngology and Head & Neck Surgery, University Medical Center Utrecht, Utrecht University, P.O. Box 85500, 3508, GA, Utrecht, the Netherlands.,UMC Utrecht Brain Center, Utrecht University, Utrecht, the Netherlands
| |
Collapse
|
33
|
Holder JT, Gifford RH. Effect of Increased Daily Cochlear Implant Use on Auditory Perception in Adults. JOURNAL OF SPEECH, LANGUAGE, AND HEARING RESEARCH : JSLHR 2021; 64:4044-4055. [PMID: 34546763 PMCID: PMC9132064 DOI: 10.1044/2021_jslhr-21-00066] [Citation(s) in RCA: 30] [Impact Index Per Article: 7.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 02/05/2021] [Revised: 05/27/2021] [Accepted: 06/28/2021] [Indexed: 06/13/2023]
Abstract
Purpose Despite the recommendation for cochlear implant (CI) processor use during all waking hours, variability in average daily wear time remains high. Previous work has shown that objective wear time is significantly correlated with speech recognition outcomes. We aimed to investigate the causal link between daily wear time and speech recognition outcomes and assess one potential underlying mechanism, spectral processing, driving the causal link. We hypothesized that increased CI use would result in improved speech recognition via improved spectral processing. Method Twenty adult CI recipients completed two study visits. The baseline visit included auditory perception testing (speech recognition and spectral processing measures), questionnaire administration, and documentation of data logging from the CI software. Participants watched an educational video, and they were informed of the compensation schedule. Participants were then asked to increase their daily CI use over a 4-week period during everyday life. Baseline measures were reassessed following the 4-week period. Results Seventeen out of 20 participants increased their daily CI use. On average, participants' speech recognition improved by 3.0, 2.4, and 7.0 percentage points per hour of increased average daily CI use for consonant-nucleus-consonant words, AzBio sentences, and AzBio sentences in noise, respectively. Questionnaire scores were similar between visits. Spectral processing showed significant improvement and accounted for a small amount of variance in the change in speech recognition values. Conclusions Improved consistency of processor use over a 4-week period yielded significant improvements in speech recognition scores. Though a significant factor, spectral processing is likely not the only mechanism driving improvement in speech recognition; further research is warranted.
Collapse
Affiliation(s)
- Jourdan T. Holder
- Department of Hearing and Speech Sciences, Vanderbilt University Medical Center, Nashville, TN
| | - René H. Gifford
- Department of Hearing and Speech Sciences, Vanderbilt University Medical Center, Nashville, TN
| |
Collapse
|
34
|
Iyer JS, Yin B, Stankovic KM, Tearney GJ. Endomicroscopy of the human cochlea using a micro-optical coherence tomography catheter. Sci Rep 2021; 11:17932. [PMID: 34504113 PMCID: PMC8429662 DOI: 10.1038/s41598-021-95991-8] [Citation(s) in RCA: 9] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/12/2021] [Accepted: 07/20/2021] [Indexed: 01/11/2023] Open
Abstract
Sensorineural hearing loss (SNHL) is one of the most profound public health concerns of the modern era, affecting 466 million people today, and projected to affect 900 million by the year 2050. Advances in both diagnostics and therapeutics for SNHL have been impeded by the human cochlea’s inaccessibility for in vivo imaging, resulting from its extremely small size, convoluted coiled configuration, fragility, and deep encasement in dense bone. Here, we develop and demonstrate the ability of a sub-millimeter-diameter, flexible endoscopic probe interfaced with a micro-optical coherence tomography (μOCT) imaging system to enable micron-scale imaging of the inner ear’s sensory epithelium in cadaveric human inner ears.
Collapse
Affiliation(s)
- Janani S Iyer
- Department of Otolaryngology - Head and Neck Surgery, Massachusetts Eye and Ear and Harvard Medical School, 243 Charles St, Boston, MA, 02114, USA.,Program in Speech and Hearing Bioscience and Technology, Harvard University Graduate School of Arts and Sciences, 1350 Massachusetts Ave, Cambridge, MA, 02138, USA.,Wellman Center for Photomedicine, Massachusetts General Hospital, Boston, MA, 02114, USA.,Department of Pathology, Massachusetts General Hospital, Boston, MA, 02114, USA
| | - Biwei Yin
- Wellman Center for Photomedicine, Massachusetts General Hospital, Boston, MA, 02114, USA.,Department of Pathology, Massachusetts General Hospital, Boston, MA, 02114, USA
| | - Konstantina M Stankovic
- Department of Otolaryngology - Head and Neck Surgery, Massachusetts Eye and Ear and Harvard Medical School, 243 Charles St, Boston, MA, 02114, USA. .,Program in Speech and Hearing Bioscience and Technology, Harvard University Graduate School of Arts and Sciences, 1350 Massachusetts Ave, Cambridge, MA, 02138, USA. .,Department of Otolaryngology - Head and Neck Surgery, Stanford University School of Medicine, Stanford, CA, 94503, USA. .,Department of Otolaryngology - Head and Neck Surgery, Massachusetts Eye and Ear and Harvard Medical School, 801 Welch Road, Stanford, CA, 94305, USA.
| | - Guillermo J Tearney
- Wellman Center for Photomedicine, Massachusetts General Hospital, Boston, MA, 02114, USA. .,Department of Pathology, Massachusetts General Hospital, Boston, MA, 02114, USA.
| |
Collapse
|
35
|
MacPhail ME, Connell NT, Totten DJ, Gray MT, Pisoni D, Yates CW, Nelson RF. Speech Recognition Outcomes in Adults With Slim Straight and Slim Modiolar Cochlear Implant Electrode Arrays. Otolaryngol Head Neck Surg 2021; 166:943-950. [PMID: 34399646 DOI: 10.1177/01945998211036339] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/15/2022]
Abstract
OBJECTIVE To compare differences in audiologic outcomes between slim modiolar electrode (SME) CI532 and slim lateral wall electrode (SLW) CI522 cochlear implant recipients. STUDY DESIGN Retrospective cohort study. SETTING Tertiary academic hospital. METHODS Comparison of postoperative AzBio sentence scores in quiet (percentage correct) in adult cochlear implant recipients with SME or SLW matched for preoperative AzBio sentence scores in quiet and aided and unaided pure tone average. RESULTS Patients with SLW (n = 52) and patients with SME (n = 37) had a similar mean (SD) age (62.0 [18.2] vs 62.6 [14.6] years, respectively), mean preoperative aided pure tone average (55.9 [20.4] vs 58.1 [16.4] dB; P = .59), and mean AzBio score (percentage correct, 11.1% [13.3%] vs 8.0% [11.5%]; P = .25). At last follow-up (SLW vs SME, 9.0 [2.9] vs 9.9 [2.6] months), postoperative mean AzBio scores in quiet were not significantly different (percentage correct, 70.8% [21.3%] vs 65.6% [24.5%]; P = .29), and data log usage was similar (12.9 [4.0] vs 11.3 [4.1] hours; P = .07). In patients with preoperative AzBio <10% correct, the 6-month mean AzBio scores were significantly better with SLW than SME (percentage correct, 70.6% [22.9%] vs 53.9% [30.3%]; P = .02). The intraoperative tip rollover rate was 8% for SME and 0% for SLW. CONCLUSIONS Cochlear implantation with SLW and SME provides comparable improvement in audiologic functioning. SME does not exhibit superior speech recognition outcomes when compared with SLW.
Collapse
Affiliation(s)
| | - Nathan T Connell
- Department of Otolaryngology-Head and Neck Surgery, School of Medicine, Indiana University, Indianapolis, Indiana, USA
| | - Douglas J Totten
- Department of Otolaryngology-Head and Neck Surgery, School of Medicine, Indiana University, Indianapolis, Indiana, USA
| | - Mitchell T Gray
- School of Medicine, Indiana University, Indianapolis, Indiana, USA
| | - David Pisoni
- Department of Otolaryngology-Head and Neck Surgery, School of Medicine, Indiana University, Indianapolis, Indiana, USA
| | - Charles W Yates
- School of Medicine, Indiana University, Indianapolis, Indiana, USA.,Department of Otolaryngology-Head and Neck Surgery, School of Medicine, Indiana University, Indianapolis, Indiana, USA
| | - Rick F Nelson
- School of Medicine, Indiana University, Indianapolis, Indiana, USA.,Department of Otolaryngology-Head and Neck Surgery, School of Medicine, Indiana University, Indianapolis, Indiana, USA
| |
Collapse
|
36
|
Hendricks CM, Cavilla MS, Usevitch DE, Bruns TL, Riojas KE, Leon L, Webster RJ, Warren FM, Abbott JJ. Magnetic Steering of Robotically Inserted Lateral-wall Cochlear-implant Electrode Arrays Reduces Forces on the Basilar Membrane In Vitro. Otol Neurotol 2021; 42:1022-1030. [PMID: 33859137 PMCID: PMC8282696 DOI: 10.1097/mao.0000000000003129] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/26/2022]
Abstract
HYPOTHESIS Undesirable forces applied to the basilar membrane during surgical insertion of lateral-wall cochlear-implant electrode arrays (EAs) can be reduced via robotic insertion with magnetic steering of the EA tip. BACKGROUND Robotic insertion of magnetically steered lateral-wall EAs has been shown to reduce insertion forces in vitro and in cadavers. No previous study of robot-assisted insertion has considered force on the basilar membrane. METHODS Insertions were executed in an open-channel scala-tympani phantom. A force plate, representing the basilar membrane, covered the channel to measure forces in the direction of the basilar membrane. An electromagnetic source generated a magnetic field to steer investigational EAs with permanent magnets at their tips, while a robot performed the insertion. RESULTS When magnetic steering was sufficient to pull the tip of the EA off of the lateral wall of the channel, it resulted in at least a 62% reduction of force on the phantom basilar membrane at insertion depths beyond 14.4 mm (p < 0.05), and these beneficial effects were maintained beyond approximately the same depth, even with 10 degrees of error in the estimation of the modiolar axis of the cochlea. When magnetic steering was not sufficient to pull the EA tip off of the lateral wall, a significant difference from the no-magnetic-steering case was not found. CONCLUSIONS This in vitro study suggests that magnetic steering of robotically inserted lateral-wall cochlear-implant EAs, given sufficient steering magnitude, can reduce forces on the basilar membrane in the first basilar turn compared with robotic insertion without magnetic steering.
Collapse
Affiliation(s)
- Cameron M Hendricks
- Department of Mechanical Engineering, University of Utah, Salt Lake City, Utah
| | - Matt S Cavilla
- Department of Mechanical Engineering, University of Utah, Salt Lake City, Utah
| | - David E Usevitch
- Department of Mechanical Engineering, University of Utah, Salt Lake City, Utah
| | - Trevor L Bruns
- Department of Mechanical Engineering, Vanderbilt University, Nashville, Tennessee
| | - Katherine E Riojas
- Department of Mechanical Engineering, Vanderbilt University, Nashville, Tennessee
| | | | - Robert J Webster
- Department of Mechanical Engineering, Vanderbilt University, Nashville, Tennessee
| | | | - Jake J Abbott
- Department of Mechanical Engineering, University of Utah, Salt Lake City, Utah
| |
Collapse
|
37
|
Torres R, Hochet B, Daoudi H, Carré F, Mosnier I, Sterkers O, Ferrary E, Nguyen Y. Atraumatic Insertion of a Cochlear Implant Pre-Curved Electrode Array by a Robot-Automated Alignment with the Coiling Direction of the Scala Tympani. Audiol Neurootol 2021; 27:148-155. [PMID: 34284383 DOI: 10.1159/000517398] [Citation(s) in RCA: 9] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/22/2020] [Accepted: 05/24/2021] [Indexed: 11/19/2022] Open
Abstract
INTRODUCTION Electrode array translocation is an unpredictable event with all types of arrays, even using a teleoperated robot in a clinical scenario. We aimed to compare the intracochlear trauma produced by the HiFocus™ Mid-Scala (MS) electrode array (Advanced Bionics, Valencia, CA, USA) using a teleoperated robot, with an automated robot connected to a navigation system to align the pre-curved tip of the electrode array with the coiling direction of the scala tympani (ST). METHODS Fifteen freshly frozen temporal bones were implanted with the MS array using the RobOtol® (Collin, Bagneux, France). In the first group (n = 10), the robot was teleoperated to insert the electrode array into the basal turn of the ST under stereomicroscopic vision, and then the array was driven by a slow-speed hydraulic insertion technique with an estimated placement of the pre-curved electrode tip. In the second group (n = 5), 3 points were obtained from the preoperative cone-beam computed tomography: the 2 first defining the ST insertion axis of the basal turn and a third one at the center of the ST at 270°. They provided the information to the automated system (RobOtol® connected with a navigation system) to automatically align the electrode array with the ST insertion axis and to aim the pre-curved tip toward the subsequent coiling of the ST. After this, the electrode array was manually advanced. Finally, the cochleae were obtained and fixed in a crystal resin, and the position of each electrode was determined by a micro-grinding technique. RESULTS In all cases, the electrode array was fully inserted into the cochlea and the depth of insertion was similar using both techniques. With the teleoperated robotic technique, translocations of the array were observed in 7/10 insertions (70%), but neither trauma nor array translocation occurred with automated robotic insertion. CONCLUSION We have successfully tested an automated insertion system (robot + navigation) that could accurately align a pre-curved electrode array to the axis of the basal turn of the ST and its subsequent coiling, which reduced intracochlear insertion trauma and translocation.
Collapse
Affiliation(s)
- Renato Torres
- Technologies et thérapie génique pour la surdité, Institut de l'Audition, Institut Pasteur/Inserm, Paris, France.,Departamento de Ciencias Fisiológicas, Facultad de Medicina, Universidad Nacional de San Agustín de Arequipa, Arequipa, Peru
| | - Baptiste Hochet
- Technologies et thérapie génique pour la surdité, Institut de l'Audition, Institut Pasteur/Inserm, Paris, France.,Unité fonctionnelle Implants auditifs et explorations fonctionnelles, Service ORL, GH Pitié-Salpêtrière, AP-HP Sorbonne Université, Paris, France
| | - Hannah Daoudi
- Technologies et thérapie génique pour la surdité, Institut de l'Audition, Institut Pasteur/Inserm, Paris, France.,Unité fonctionnelle Implants auditifs et explorations fonctionnelles, Service ORL, GH Pitié-Salpêtrière, AP-HP Sorbonne Université, Paris, France
| | - Fabienne Carré
- Technologies et thérapie génique pour la surdité, Institut de l'Audition, Institut Pasteur/Inserm, Paris, France.,Unité fonctionnelle Implants auditifs et explorations fonctionnelles, Service ORL, GH Pitié-Salpêtrière, AP-HP Sorbonne Université, Paris, France
| | - Isabelle Mosnier
- Technologies et thérapie génique pour la surdité, Institut de l'Audition, Institut Pasteur/Inserm, Paris, France.,Unité fonctionnelle Implants auditifs et explorations fonctionnelles, Service ORL, GH Pitié-Salpêtrière, AP-HP Sorbonne Université, Paris, France
| | - Olivier Sterkers
- Technologies et thérapie génique pour la surdité, Institut de l'Audition, Institut Pasteur/Inserm, Paris, France.,Unité fonctionnelle Implants auditifs et explorations fonctionnelles, Service ORL, GH Pitié-Salpêtrière, AP-HP Sorbonne Université, Paris, France
| | - Evelyne Ferrary
- Technologies et thérapie génique pour la surdité, Institut de l'Audition, Institut Pasteur/Inserm, Paris, France.,Unité fonctionnelle Implants auditifs et explorations fonctionnelles, Service ORL, GH Pitié-Salpêtrière, AP-HP Sorbonne Université, Paris, France
| | - Yann Nguyen
- Technologies et thérapie génique pour la surdité, Institut de l'Audition, Institut Pasteur/Inserm, Paris, France.,Unité fonctionnelle Implants auditifs et explorations fonctionnelles, Service ORL, GH Pitié-Salpêtrière, AP-HP Sorbonne Université, Paris, France
| |
Collapse
|
38
|
Jia H, Pan J, Gu W, Tan H, Chen Y, Zhang Z, Jiang M, Li Y, Sterkers O, Wu H. Robot-Assisted Electrode Array Insertion Becomes Available in Pediatric Cochlear Implant Recipients: First Report and an Intra-Individual Study. Front Surg 2021; 8:695728. [PMID: 34307444 PMCID: PMC8294934 DOI: 10.3389/fsurg.2021.695728] [Citation(s) in RCA: 10] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/15/2021] [Accepted: 06/02/2021] [Indexed: 11/28/2022] Open
Abstract
Background: As an advanced surgical technique to reduce trauma to the inner ear, robot-assisted electrode array (EA) insertion has been applied in adult cochlear implantation (CI) and was approved as a safe surgical procedure that could result in better outcomes. As the mastoid and temporal bones are generally smaller in children, which would increase the difficulty for robot-assisted manipulation, the clinical application of these systems for CI in children has not been reported. Given that the pediatric candidate is the main population, we aim to investigate the safety and reliability of robot-assisted techniques in pediatric cochlear implantation. Methods: Retrospective cohort study at a referral center in Shanghai including all patients of simultaneous bilateral CI with robotic assistance on one side (RobOtol® system, Collin ORL, Bagneux, France), and manual insertion on the other (same brand of EA and CI in both side), from December 2019 to June 2020. The surgical outcomes, radiological measurements (EA positioning, EA insertion depth, mastoidectomy size), and audiological outcomes (Behavior pure-tone audiometry) were evaluated. Results: Five infants (17.8 ± 13.5 months, ranging from 10 to 42 months) and an adult (39 years old) were enrolled in this study. Both perimodiolar and lateral wall EAs were included. The robot-assisted EA insertion was successfully performed in all cases, although the surgical zone in infants was about half the size in adults, and no difference was observed in mastoidectomy size between robot-assisted and manual insertion sides (p = 0.219). The insertion depths of EA with two techniques were similar (P = 0.583). The robot-assisted technique showed no scalar deviation, but scalar deviation occurred for one manually inserted pre-curved EA (16%). Early auditory performance was similar to both techniques. Conclusion: Robot-assisted technique for EA insertion is approved to be used safely and reliably in children, which is possible and potential for better scalar positioning and might improve long-term auditory outcome. Standard mastoidectomy size was enough for robot-assisted technique. This first study marks the arrival of the era of robotic CI for all ages.
Collapse
Affiliation(s)
- Huan Jia
- Department of Otorhinolaryngology Head and Neck Surgery, Shanghai Ninth People's Hospital, Shanghai Jiaotong University School of Medicine, Shanghai, China.,Ear Institute, Shanghai Jiaotong University School of Medicine, Shanghai, China.,Shanghai Key Laboratory of Translational Medicine on Ear and Nose Diseases, Shanghai, China
| | - Jinxi Pan
- Department of Otorhinolaryngology Head and Neck Surgery, Shanghai Ninth People's Hospital, Shanghai Jiaotong University School of Medicine, Shanghai, China.,Ear Institute, Shanghai Jiaotong University School of Medicine, Shanghai, China.,Shanghai Key Laboratory of Translational Medicine on Ear and Nose Diseases, Shanghai, China
| | - Wenxi Gu
- Department of Otorhinolaryngology Head and Neck Surgery, Shanghai Ninth People's Hospital, Shanghai Jiaotong University School of Medicine, Shanghai, China.,Ear Institute, Shanghai Jiaotong University School of Medicine, Shanghai, China.,Shanghai Key Laboratory of Translational Medicine on Ear and Nose Diseases, Shanghai, China
| | - Haoyue Tan
- Department of Otorhinolaryngology Head and Neck Surgery, Shanghai Ninth People's Hospital, Shanghai Jiaotong University School of Medicine, Shanghai, China.,Ear Institute, Shanghai Jiaotong University School of Medicine, Shanghai, China.,Shanghai Key Laboratory of Translational Medicine on Ear and Nose Diseases, Shanghai, China
| | - Ying Chen
- Department of Otorhinolaryngology Head and Neck Surgery, Shanghai Ninth People's Hospital, Shanghai Jiaotong University School of Medicine, Shanghai, China.,Ear Institute, Shanghai Jiaotong University School of Medicine, Shanghai, China.,Shanghai Key Laboratory of Translational Medicine on Ear and Nose Diseases, Shanghai, China
| | - Zhihua Zhang
- Department of Otorhinolaryngology Head and Neck Surgery, Shanghai Ninth People's Hospital, Shanghai Jiaotong University School of Medicine, Shanghai, China.,Ear Institute, Shanghai Jiaotong University School of Medicine, Shanghai, China.,Shanghai Key Laboratory of Translational Medicine on Ear and Nose Diseases, Shanghai, China
| | - Mengda Jiang
- Department of Radiology, Shanghai Ninth People's Hospital, Shanghai Jiao Tong University School of Medicine, Shanghai, China
| | - Yun Li
- Department of Otorhinolaryngology Head and Neck Surgery, Shanghai Ninth People's Hospital, Shanghai Jiaotong University School of Medicine, Shanghai, China.,Ear Institute, Shanghai Jiaotong University School of Medicine, Shanghai, China.,Shanghai Key Laboratory of Translational Medicine on Ear and Nose Diseases, Shanghai, China
| | - Olivier Sterkers
- Department of Otorhinolaryngology Head and Neck Surgery, Shanghai Ninth People's Hospital, Shanghai Jiaotong University School of Medicine, Shanghai, China.,APHP, Groupe hospitalo-Universitaire Pitié Salpêtrière, Otorhinolaryngology Department, Unit of Otology, Auditory Implants and Skull Base Surgery, Paris, France
| | - Hao Wu
- Department of Otorhinolaryngology Head and Neck Surgery, Shanghai Ninth People's Hospital, Shanghai Jiaotong University School of Medicine, Shanghai, China.,Ear Institute, Shanghai Jiaotong University School of Medicine, Shanghai, China.,Shanghai Key Laboratory of Translational Medicine on Ear and Nose Diseases, Shanghai, China
| |
Collapse
|
39
|
Weinmann C, Baumann U, Leinung M, Stöver T, Helbig S. Vertigo Associated With Cochlear Implant Surgery: Correlation With Vertigo Diagnostic Result, Electrode Carrier, and Insertion Angle. Front Neurol 2021; 12:663386. [PMID: 34177768 PMCID: PMC8226011 DOI: 10.3389/fneur.2021.663386] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/02/2021] [Accepted: 05/04/2021] [Indexed: 11/13/2022] Open
Abstract
Objective: Vertigo is a common side effect of cochlear implant (CI) treatment. This prospective study examines the incidence of postoperative vertigo over time and aims to analyze influencing factors such as electrode design and insertion angle (IA). Study Design and Setting: This is a prospective study which has been conducted at a tertiary referral center (academic hospital). Patients: A total of 29 adults were enrolled and received a unilateral CI using one of six different electrode carriers, which were categorized into "structure-preserving" (I), "potentially structure-preserving" (II), and "not structure-preserving" (III). Intervention: Subjective vertigo was assessed by questionnaires at five different time-points before up to 6 months after surgery. The participants were divided into four groups depending on the time of the presence of vertigo before and after surgery. Preoperatively and at 6 months postoperatively, a comprehensive vertigo diagnosis consisting of Romberg test, Unterberger test, subjective visual vertical, optokinetic test, video head impulse test, and caloric irrigation test was performed. In addition, the IA was determined, and the patients were divided in two groups (<430°; ≥430°). Main Outcome Measures: The incidence of vertigo after CI surgery (group 1) was reported, as well as the correlation of subjective vertigo with electrode array categories (I-III) and IA. Results: Among the participants, 45.8% experienced new vertigo after implantation. Based on the questionnaire data, a vestibular origin was suspected in 72.7%. The results did not show a significant correlation with subjective vertigo for any of the performed tests. In group 1 with postoperative vertigo, 18% of patients showed conspicuous results in a quantitative analysis of caloric irrigation test despite the fact that the category I or II electrodes were implanted, which are suitable for structure preservation. Average IA was 404° for the overall group and 409° for group 1. There was no statistically significant correlation between IA and perceived vertigo. Conclusions: Though vertigo after CI surgery seems to be a common complication, the test battery used here could not objectify the symptoms. Further studies should clarify whether this is due to the multifactorial cause of vertigo or to the lack of sensitivity of the tests currently in use. The proof of reduced probability for vertigo when using atraumatic electrode carrier was not successful, nor was the proof of a negative influence of the insertion depth.
Collapse
Affiliation(s)
- Charlotte Weinmann
- Department of Otorhinolaryngology, Goethe-University Frankfurt, Frankfurt, Germany
| | - Uwe Baumann
- Department of Audiological Acoustics, Goethe-University Frankfurt, Frankfurt, Germany
| | - Martin Leinung
- Department of Otorhinolaryngology, Goethe-University Frankfurt, Frankfurt, Germany
| | - Timo Stöver
- Department of Otorhinolaryngology, Goethe-University Frankfurt, Frankfurt, Germany
| | - Silke Helbig
- Department of Otorhinolaryngology, Goethe-University Frankfurt, Frankfurt, Germany
| |
Collapse
|
40
|
Warnecke A, Prenzler N, Harre J, Köhl U, Gärtner L, Lenarz T, Laner-Plamberger S, Wietzorrek G, Staecker H, Lassacher T, Hollerweger J, Gimona M, Rohde E. First-in-human intracochlear application of human stromal cell-derived extracellular vesicles. J Extracell Vesicles 2021; 10:e12094. [PMID: 34136108 PMCID: PMC8178433 DOI: 10.1002/jev2.12094] [Citation(s) in RCA: 46] [Impact Index Per Article: 11.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/22/2021] [Revised: 03/15/2021] [Accepted: 04/22/2021] [Indexed: 12/20/2022] Open
Abstract
Extracellular vesicles (EVs) derived from the secretome of human mesenchymal stromal cells (MSC) contain numerous factors that are known to exert anti‐inflammatory effects. MSC‐EVs may serve as promising cell‐based therapeutics for the inner ear to attenuate inflammation‐based side effects from cochlear implantation which represents an unmet clinical need. In an individual treatment performed on a ‘named patient basis’, we intraoperatively applied allogeneic umbilical cord‐derived MSC‐EVs (UC‐MSC‐EVs) produced according to good manufacturing practice. A 55‐year‐old patient suffering from Menière's disease was treated with intracochlear delivery of EVs prior to the insertion of a cochlear implant. This first‐in‐human use of UC‐MSC‐EVs demonstrates the feasibility of this novel adjuvant therapeutic approach. The safety and efficacy of intracochlear EV‐application to attenuate side effects of cochlea implants have to be determined in controlled clinical trials.
Collapse
Affiliation(s)
- Athanasia Warnecke
- Department of Otorhinolaryngology, Head and Neck Surgery Hannover Medical School Hannover Germany
| | - Nils Prenzler
- Department of Otorhinolaryngology, Head and Neck Surgery Hannover Medical School Hannover Germany
| | - Jennifer Harre
- Department of Otorhinolaryngology, Head and Neck Surgery Hannover Medical School Hannover Germany
| | - Ulrike Köhl
- Institute for Cellular Therapeutics Hannover and Institute of Clinical Immunology Hannover Medical School University of Leipzig as well as Fraunhofer Institute for Cell Therapy and Immunology (IZI) Leipzig Germany
| | - Lutz Gärtner
- Department of Otorhinolaryngology, Head and Neck Surgery Hannover Medical School Hannover Germany
| | - Thomas Lenarz
- Department of Otorhinolaryngology, Head and Neck Surgery Hannover Medical School Hannover Germany
| | - Sandra Laner-Plamberger
- Department of Transfusion Medicine University Hospital Salzburger Landeskliniken GesmbH (SALK) and Paracelsus Medical University (PMU) Salzburg Austria
| | - Georg Wietzorrek
- Institute of Molecular and Cellular Pharmacology Medical University of Innsbruck Innsbruck Austria
| | - Hinrich Staecker
- Department of Otolaryngology Head and Neck Surgery University of Kansas School of Medicine Kansas City Kansas USA
| | - Teresa Lassacher
- GMP Unit Spinal Cord Injury & Tissue Regeneration Centre Salzburg (SCI-TReCS) Paracelsus Medical University (PMU) Salzburg Austria.,Research Program Nanovesicular Therapeutics Paracelsus Medical University (PMU) Salzburg Austria
| | - Julia Hollerweger
- GMP Unit Spinal Cord Injury & Tissue Regeneration Centre Salzburg (SCI-TReCS) Paracelsus Medical University (PMU) Salzburg Austria.,Research Program Nanovesicular Therapeutics Paracelsus Medical University (PMU) Salzburg Austria
| | - Mario Gimona
- Department of Transfusion Medicine University Hospital Salzburger Landeskliniken GesmbH (SALK) and Paracelsus Medical University (PMU) Salzburg Austria.,GMP Unit Spinal Cord Injury & Tissue Regeneration Centre Salzburg (SCI-TReCS) Paracelsus Medical University (PMU) Salzburg Austria.,Research Program Nanovesicular Therapeutics Paracelsus Medical University (PMU) Salzburg Austria.,Research and Transfer Centre for Extracellular Vesicle Theralytic Technologies Salzburg Austria
| | - Eva Rohde
- Department of Transfusion Medicine University Hospital Salzburger Landeskliniken GesmbH (SALK) and Paracelsus Medical University (PMU) Salzburg Austria.,GMP Unit Spinal Cord Injury & Tissue Regeneration Centre Salzburg (SCI-TReCS) Paracelsus Medical University (PMU) Salzburg Austria.,Research and Transfer Centre for Extracellular Vesicle Theralytic Technologies Salzburg Austria
| |
Collapse
|
41
|
Abstract
OBJECTIVE To study the surgical results, intracochlear position of the electrode array (EA) and auditory performance of the LISTENT LCI-20PI cochlear implant device, and daily use status at 3 years. STUDY DESIGN A retrospective study. SETTING A single-tertiary referral center. PATIENTS Between January and December 2016, 20 patients underwent cochlear implantation using the LISTENT LCI-20PI (lateral wall EA). INTERVENTION Cochlear implantation. MAIN OUTCOME MEASURES Measurement of cochlear size, extent of posterior tympanotomy, and insertion depth. Scalar position of the EA evaluated by 3D reconstruction. Auditory outcomes 1 year after implantation and daily use status at 3 years. RESULTS EAs were completely inserted in all cases with an insertion depth of 288 ± 36.8 degrees. One year later, the average sentence recognition score (SRS) was 90 ± 21.7%. EA scalar location was analyzed in 18 patients. Thirteen EAs (72.2%) were fully inserted into the scala tympani (ST) and 5 (27.8%) had shifted from the ST to the scala vestibuli (SV). There was no statistically significant difference in cochlear size, extent of posterior tympanotomy, or insertion depth between these two groups. EAs inserted by cochleostomy had a higher chance of scalar shift than those inserted via the round window (60% vs 15.4%, p = 0.099). SRS at 1 year with full ST insertion was significantly better than in those with scalar shift (99 ± 1.3% vs 83 ± 16.5%, p = 0.002). Three years after implantation, 92% of patients were daily users and 46% were telephone users. CONCLUSIONS The LISTENT LCI-20PI provided accredited hearing rehabilitation with a short insertion depth. Full insertion into the ST was associated with better cochlear implantation outcomes.
Collapse
|
42
|
The Effect of Ultra-slow Velocities on Insertion Forces: A Study Using a Highly Flexible Straight Electrode Array. Otol Neurotol 2021; 42:e1013-e1021. [PMID: 33883518 DOI: 10.1097/mao.0000000000003148] [Citation(s) in RCA: 11] [Impact Index Per Article: 2.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/25/2022]
Abstract
OBJECTIVE The present study sought to 1) characterize insertion forces resulting from a flexible straight electrode array (EA) inserted at slow and ultra-slow insertion velocities, and 2) evaluate if ultra-slow velocities decrease insertion forces independent of other variables. BACKGROUND Low insertion forces are desirable in cochlear implant (CI) surgery to reduce trauma and preserve hearing. Recently, ultra-slow insertion velocities (lower than manually feasible) have been shown to produce significantly lower insertion forces using other EAs. METHODS Five flexible straight EAs were used to record insertion forces into an inelastic artificial scala tympani model. Eleven trial recordings were performed for each EA at five predetermined automated, continuous insertion velocities ranging from 0.03 to 1.6 mm/s. RESULTS An ultra-slow insertion velocity of 0.03 mm/s resulted in a median insertion force of 0.010 N at 20 mm of insertion depth, and 0.026 N at 24.3 mm-the final insertion depth. These forces represent only 24 to 29% of those measured using 1.6 mm/s. After controlling for insertion depth of the EA into the artificial scala tympani model and trial insertion number, decreasing the insertion velocity from 0.4 to 0.03 mm/s resulted in a 50% decrease in the insertion forces. CONCLUSION Using the tested EA ultra-slow velocities can decrease insertion forces, independent of variables like insertion depth. Our results suggest ultra-slow velocities can reduce insertion forces at least 60%, compared with humanly feasible continuous velocities (≥0.9 mm/s).
Collapse
|
43
|
Duration of Processor Use Per Day Is Significantly Correlated With Speech Recognition Abilities in Adults With Cochlear Implants. Otol Neurotol 2021; 41:e227-e231. [PMID: 31789794 DOI: 10.1097/mao.0000000000002477] [Citation(s) in RCA: 49] [Impact Index Per Article: 12.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/25/2022]
Abstract
OBJECTIVE Quantify the relationship between average hours of processor use per day and measures of speech recognition in post-lingually deafened adults with cochlear implants. SETTING Cochlear implant (CI) program at a tertiary medical center. PATIENTS Three hundred adult (mean age = 64, 130 women) CI users were included. MAIN OUTCOME MEASURES Correlation analyses were completed for CI-aided speech recognition (Consonant-Nucleus-Consonant [CNC] monosyllables and AzBio sentences) at approximately 12 months post-implantation and average hours of processor use per day, which was extracted from the CI programming software. RESULTS Average processor use was 10.2 hours per day (range, 0.1-22.7), and average speech recognition scores were 49.9 and 61.7% for CNC and AzBio sentence recognition, respectively. We found a strong, significant correlation between hours of processor use per day and consonant-nucleus-consonant (CNC) word recognition (rs = 0.61, p < 0.0001) and AzBio sentence recognition (rs = 0.56, p < 0.0001). CONCLUSIONS Results suggest that highest speech recognition outcomes are correlated with greater than 10 hours of CI use per day. Further research is needed to assess the causal link between daily CI use and speech recognition abilities.
Collapse
|
44
|
Abstract
OBJECTIVE The intracochlear position of an electrode array may influence the outcome after cochlear implantation. The design of the electrode array can increase the risk of trauma causing penetration of the basilar membrane or shift of the electrode array into the scala vestibuli. The aim of the present study was to identify a scalar shift after implantation of two different electrode arrays developed by one manufacturer. STUDY DESIGN Retrospective analysis. SETTING Tertiary referral center. PATIENTS AND INTERVENTION Cochlear implant recipients implanted between 2010 and 2014 and receiving either a mid-scala (n = 30) or a perimodiolar (n = 30) electrode array. MAIN OUTCOME MEASURE Occurrence of scalar shift in association with the electrode type. RESULTS Scalar shift occurred in 26.7% (8 of 30) of the patients implanted with a perimodiolar electrode array and in 6.7% (2 of 30) of the patients implanted with the mid-scala electrode array. The mean insertion depth in the patients experiencing scalar shift after implantation of the mid-scala electrode was much deeper (21.59 ± 0.34 mm) when compared with the mean insertion depth of the patients with scalar shift after implantation with a perimodiolar electrode array (17.85 ± 2.19 mm). There tends to be a correlation between the cochlear length and the occurrence of a scalar shift. However, the number of patients with scalar shift in the mid-scala group is rather small. CONCLUSION Based on the presented data, more patients implanted with a perimodiolar electrode array have a scalar shift when compared with the midscalar electrode array.
Collapse
|
45
|
Oh J, Cheon JE, Park J, Choi YH, Cho YJ, Lee S, Oh SH, Shin SM, Park SW. Cochlear duct length and cochlear distance on preoperative CT: imaging markers for estimating insertion depth angle of cochlear implant electrode. Eur Radiol 2021; 31:1260-1267. [PMID: 33471218 DOI: 10.1007/s00330-020-07580-4] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/28/2020] [Revised: 08/28/2020] [Accepted: 12/01/2020] [Indexed: 10/22/2022]
Abstract
OBJECTIVES Preoperative estimation of the insertion depth angle of cochlear implant (CI) electrodes is essential for surgical planning. The purpose of this study was to determine the cochlear size using preoperative CT and to investigate the correlation between cochlear size and insertion depth angle in morphologically normal cochlea. METHODS Thirty-five children who underwent CI were included in this study. Cochlear duct length (CDL) and the diameter of the cochlear basal turn (distance A/B) on preoperative CT and the insertion depth angle of the CI electrode on postoperative radiographs were independently measured by two readers. Correlation between cochlear size and insertion depth angle was evaluated. Interobserver agreement was calculated using the intraclass correlation coefficient (ICC). RESULTS The mean CDL, distance A, and distance B of 70 ears were 36.20 ± 1.57 mm, 8.67 ± 0.42 mm, and 5.73 ± 0.32 mm, respectively. The mean insertion depth angle was 431.45 ± 38.42°. Interobserver agreements of CDL, distance A/B, and insertion depth angle were fair to excellent (ICC 0.864, 0.862, 0.529, and 0.958, respectively). Distance A (r = - 0.7643) and distance B (r = - 0.7118) showed a negative correlation with insertion depth angle, respectively (p < 0.0001). However, the correlation between CDL and insertion depth angle was not statistically significant (r = - 0.2333, p > 0.05). CONCLUSIONS The CDL and cochlear distance can be reliably obtained from preoperative CT. Distance A can be used as a predictive marker for estimating insertion depth angle during CI surgery.
Collapse
Affiliation(s)
- Jiseon Oh
- Department of Radiology, Seoul National University College of Medicine, 101 Daehak-ro, Jongro-gu, Seoul, 03080, South Korea
| | - Jung-Eun Cheon
- Department of Radiology, Seoul National University College of Medicine, 101 Daehak-ro, Jongro-gu, Seoul, 03080, South Korea. .,Institute of Radiation Medicine, SNUMRC (Seoul National University Medical Research Center), Seoul, South Korea.
| | - Junghoan Park
- Department of Radiology, Seoul National University College of Medicine, 101 Daehak-ro, Jongro-gu, Seoul, 03080, South Korea
| | - Young Hun Choi
- Department of Radiology, Seoul National University College of Medicine, 101 Daehak-ro, Jongro-gu, Seoul, 03080, South Korea.,Institute of Radiation Medicine, SNUMRC (Seoul National University Medical Research Center), Seoul, South Korea
| | - Yeon Jin Cho
- Department of Radiology, Seoul National University College of Medicine, 101 Daehak-ro, Jongro-gu, Seoul, 03080, South Korea.,Institute of Radiation Medicine, SNUMRC (Seoul National University Medical Research Center), Seoul, South Korea
| | - Seunghyun Lee
- Department of Radiology, Seoul National University College of Medicine, 101 Daehak-ro, Jongro-gu, Seoul, 03080, South Korea.,Institute of Radiation Medicine, SNUMRC (Seoul National University Medical Research Center), Seoul, South Korea
| | - Seung Ha Oh
- Department of Otorhinolaryngology-Head & Neck Surgery, Seoul National University College of Medicine, Seoul, South Korea
| | - Su-Mi Shin
- Department of Radiology, Seoul National University Seoul Metropolitan Government Boramae Medical Center, Seoul, South Korea
| | - Sun-Won Park
- Department of Radiology, Seoul National University Seoul Metropolitan Government Boramae Medical Center, Seoul, South Korea
| |
Collapse
|
46
|
Dziemba OC, Aristeidou A, Brill S. Slope of electrically evoked compound action potential amplitude growth function is site-dependent. Cochlear Implants Int 2020; 22:136-147. [PMID: 33297870 DOI: 10.1080/14670100.2020.1853956] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/08/2023]
Abstract
OBJECTIVES In human cochlear implant (CI) recipients, the slope of the electrically evoked compound action potential (ECAP) amplitude growth function (AGF) is not very well investigated, in comparison to the threshold derived from the AGF. This is despite the fact that it was shown in animal experiments that the slope correlates with the number of excitable neurons. The rationale of this study was to establish baseline data of the AGF slope for possible clinical applications, while investigating stability over time and dependence on cochlear site. DESIGN ECAP AGFs of 16 ears implanted with MED-EL CIs were recorded on all electrode contacts during the normal clinical routine at 4 different points in time. RESULTS Due to patient availability, not all 16 ears could be measured at all 4 points in time. A dependence of the slope on the electrode position was visible and statistically significant: At the three electrode contacts at the apical end of the array, the slope is greater compared to the medial and basal region of the cochlea. CONCLUSION The three most apical electrode contacts show greater slopes of ECAP AGF recordings. Our data of the cohort slopes show mild effects between the 4 different points in time.
Collapse
Affiliation(s)
- Oliver C Dziemba
- Department of ENT, Head & Neck Surgery, University Medicine Greifswald, Greifswald, Germany
| | - Aristotelis Aristeidou
- Department of ENT, Head & Neck Surgery, University Medicine Greifswald, Greifswald, Germany
| | - Stefan Brill
- MED-EL Elektromedizinische Geräte Deutschland GmbH, Starnberg, Germany
| |
Collapse
|
47
|
Jwair S, Prins A, Wegner I, Stokroos RJ, Versnel H, Thomeer HGXM. Scalar Translocation Comparison Between Lateral Wall and Perimodiolar Cochlear Implant Arrays - A Meta-Analysis. Laryngoscope 2020; 131:1358-1368. [PMID: 33159469 PMCID: PMC8246990 DOI: 10.1002/lary.29224] [Citation(s) in RCA: 48] [Impact Index Per Article: 9.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/07/2020] [Revised: 10/15/2020] [Accepted: 10/16/2020] [Indexed: 12/15/2022]
Abstract
Objectives/Hypothesis Two types of electrode arrays for cochlear implants (CIs) are distinguished: lateral wall and perimodiolar. Scalar translocation of the array can lead to intracochlear trauma by penetrating from the scala tympani into the scala vestibuli or scala media, potentially negatively affecting hearing performance of CI users. This systematic review compares the lateral wall and perimodiolar arrays with respect to scalar translocation. Study Design Systematic review. Methods PubMed, Embase, and Cochrane databases were reviewed for studies published within the last 11 years. No other limitations were set. All studies with original data that evaluated the occurrence of scalar translocation or tip fold‐over (TF) with postoperative computed tomography (CT) following primary cochlear implantation in bilateral sensorineuronal hearing loss patients were considered to be eligible. Data were extracted independently by two reviewers. Results We included 33 studies, of which none were randomized controlled trials. Meta‐analysis of five cohort studies comparing scalar translocation between lateral wall and perimodiolar arrays showed that lateral wall arrays have significantly lower translocation rates (7% vs. 43%; pooled odds ratio = 0.12). Translocation was negatively associated with speech perception scores (weighted mean 41% vs. 55%). Tip fold‐over of the array was more frequent with perimodiolar arrays (X2 = 6.8, P < .01). Conclusions Scalar translocation and tip fold‐overs occurred more frequently with perimodiolar arrays than with lateral wall arrays. In addition, translocation of the array negatively affects hearing with the cochlear implant. Therefore, if one aims to minimize clinically relevant intracochlear trauma, lateral wall arrays would be the preferred option for cochlear implantation. Laryngoscope, 131:1358–1368, 2021
Collapse
Affiliation(s)
- Saad Jwair
- Department of Otorhinolaryngology and Head & Neck Surgery, University Medical Center Utrecht, Utrecht University, Utrecht, The Netherlands.,UMC Utrecht Brain Center, Utrecht University, Utrecht, The Netherlands
| | - Adrianus Prins
- Department of Otorhinolaryngology and Head & Neck Surgery, University Medical Center Utrecht, Utrecht University, Utrecht, The Netherlands
| | - Inge Wegner
- Department of Otorhinolaryngology and Head & Neck Surgery, University Medical Center Utrecht, Utrecht University, Utrecht, The Netherlands
| | - Robert J Stokroos
- Department of Otorhinolaryngology and Head & Neck Surgery, University Medical Center Utrecht, Utrecht University, Utrecht, The Netherlands.,UMC Utrecht Brain Center, Utrecht University, Utrecht, The Netherlands
| | - Huib Versnel
- Department of Otorhinolaryngology and Head & Neck Surgery, University Medical Center Utrecht, Utrecht University, Utrecht, The Netherlands.,UMC Utrecht Brain Center, Utrecht University, Utrecht, The Netherlands
| | - Hans G X M Thomeer
- Department of Otorhinolaryngology and Head & Neck Surgery, University Medical Center Utrecht, Utrecht University, Utrecht, The Netherlands.,UMC Utrecht Brain Center, Utrecht University, Utrecht, The Netherlands
| |
Collapse
|
48
|
Hearing Preservation Outcomes Using a Precurved Electrode Array Inserted With an External Sheath. Otol Neurotol 2020; 41:33-38. [PMID: 31746820 DOI: 10.1097/mao.0000000000002426] [Citation(s) in RCA: 26] [Impact Index Per Article: 5.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/26/2022]
Abstract
OBJECTIVES Describe audiologic outcomes in hearing preservation cochlear implantation (CI) using a precurved electrode array inserted using an external sheath and evaluate association of electrode positioning and preservation of residual hearing. STUDY DESIGN Retrospective review. SETTING Tertiary otologic center. PATIENTS Twenty-four adult patients who underwent hearing preservation CI with precurved electrode array. INTERVENTIONS CI, intraoperative computed tomography (CT) OUTCOME MEASURES:: Audiologic measures (consonant-nucleus-consonant [CNC] words, AzBio sentences, low-frequency pure tone averages [LFPTA]) and electrode location (scalar location, electrode-to-modiolus distance ((Equation is included in full-text article.)), angular insertion depth). RESULTS Twenty-four adults with less than 80 dB LFPTA with a precurved electrode array inserted using an external sheath; 16 underwent intraoperative CT. LFPTA was 58.5 dB HL preoperatively, with a 17.3 dB threshold shift at CI activation (p = 0.005). CNC word scores improved from 6% preoperatively to 64% at 6 months postoperatively (p < 0.0001). There was one scalar translocation and no tip fold-overs. The average angular insertion depth was 388.2 degrees, and the average (Equation is included in full-text article.)across all electrodes was 0.36 mm. Multivariate regression revealed a significant correlation between CNC scores at 6 months and angular insertion depth (p = 0.0122; r = 0.45, adjusted r = 0.35). Change in LFPTA was not significantly associated with angular insertion depth or (Equation is included in full-text article.). CONCLUSIONS A low rate of translocation allows a precurved electrode array inserted using an external sheath to maintain hearing preservation rates comparable to straight electrode arrays. With scala tympani insertion, angular insertion depth is a positive marker of improved speech performance postoperatively but may be a confounder variable based on individual cochlear size.
Collapse
|
49
|
Reiss LA. Cochlear implants and other inner ear prostheses: today and tomorrow. CURRENT OPINION IN PHYSIOLOGY 2020; 18:49-55. [PMID: 32905432 DOI: 10.1016/j.cophys.2020.08.001] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/22/2022]
Abstract
Cochlear implants (CIs) are implantable auditory prostheses designed to restore access to sound in deaf individuals via direct electrical stimulation of the auditory nerve. While CIs have been successful in restoring speech perception to many deaf patients, outcomes are variable and speech recognition in noise remains a problem. This chapter will review the factors underlying this variability, and discuss significant recent innovations to address these issues including neural health preservation, characterization, and regeneration, and other inner ear prostheses. The emerging role of central auditory plasticity will also be discussed. Together, these advances will point to the likely future directions for advancing the next generation of CIs and other inner ear prostheses.
Collapse
Affiliation(s)
- Lina Aj Reiss
- Oregon Health & Science University, Otolaryngology, Oregon Health & Science University, 3181 SW Sam Jackson Park Road, Mailcode NRC04, OHSU, Portland 97239, United States
| |
Collapse
|
50
|
Abstract
OBJECTIVES Preservation of residual hearing is one of the main goals in present cochlear implantation surgery. Especially for this purpose, smaller and softer electrode carriers were developed that are to be inserted through the round window membrane to minimize trauma. By using these electrodes and insertion technique, residual hearing can be preserved in a large number of patients. Unfortunately, some of these patients with initially preserved residual hearing after cochlear implantation lose it later on. The reason for this is unknown but it is speculated about a correlation with an increase in impedance, since increased impedance values are linked to intracochlear inflammation and tissue reaction. Our hypothesis for this study design was that an increase in impedance predicts changes in residual hearing under clinical conditions. DESIGN Data of all adult patients (N = 122) receiving a Hybrid-L24 cochlear implant at our center between 2005 and early 2015 were retrospectively evaluated. Impedance values in Common Ground mode as measured during clinical routine and referring audiological test data (audiometric thresholds under headphones) were collected. Changes between consecutive measurements were calculated for impedance values and hearing thresholds for each patient. Correlations between changes in impedances and acoustic hearing thresholds were calculated. Average values were compared as well as patients with largest impedance changes within the observation period were evaluated separately. RESULTS Group mean values of impedances were between 5 and 7 kΩ and stable over time with higher values on basal electrode contacts compared with apical contacts. Average hearing thresholds at the time of initial fitting were between 40 to 50 dB (250 Hz) and 90 dB (1 kHz) with a loss of about 10 dB compared with preoperative values. Correlation between impedance changes and threshold changes was found, but too inconsistently to imply a true relationship. When evaluating the 20 patients with the largest impedance changes during the observation period (all >1 kΩ from one appointment to the next one), some patients were found where hearing loss is timely connected and highly correlated with an unusual impedance change. But large impedance changes were also observed without affecting hearing thresholds and hearing loss was found without impedance change. CONCLUSIONS Changes in impedance as measured during clinical routine cannot be taken as an indicator for a late acoustic hearing loss.
Collapse
|