1
|
Al-Otaibi Y, Alkhathami A, Alojair RS, Alharthi MA, Alshahrani Y, Alaklabi SS, Alqahtani MM, Almalki AM, Asiri AY. Awareness and Attitude Regarding Contact Lens Use Among Female Students at the University of Bisha: A Cross-Sectional Study. Cureus 2024; 16:e58216. [PMID: 38745816 PMCID: PMC11090884 DOI: 10.7759/cureus.58216] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Accepted: 04/13/2024] [Indexed: 05/16/2024] Open
Abstract
INTRODUCTION Given the growing popularity of contact lenses among female students in Saudi Arabia for various reasons including vision correction as well as aesthetic and therapeutic purposes, it is essential to understand the knowledge about them, their uses, and how to handle them, given their significance in healthcare. METHODS A cross-sectional study design was utilized in this research, employing data from a sample of 413 female students at the University of Bisha. The participants completed a self-administered questionnaire and were ensured anonymity. RESULTS The study results showed that 52.9% (n=218) had a good knowledge level while 47.1% (n=195) had poor knowledge about contact lenses use. The results established a statistically significant association between region, faculty, and study year (p<0.005) with p-values of 0.002, 0.001, and 0.005, respectively, and level of knowledge about contact lens use. There was no statistically significant association between the age of the participants and the level of knowledge about contact lens use. CONCLUSION Although there was a generally good level of awareness about contact lens use among female students, there is still insufficiency in knowledge with regard to particular aspects such as cleaning the contact lenses and contact lens cover. The study finds the need for more ocular educational sessions with ophthalmologists to increase awareness about contact lenses.
Collapse
Affiliation(s)
- Yousef Al-Otaibi
- Department of Ophthalmology, Faculty of Medicine, University of Bisha, Bisha, SAU
| | | | - Rana Saad Alojair
- Department of Ophthalmology, Armed Forced Hospital Southern Region, Khamis Mushait, SAU
| | | | - Yazeed Alshahrani
- College of Medicine, Faculty of Medicine, University of Bisha, Bisha, SAU
| | - Sara Saeed Alaklabi
- Department of Internal Medicine, Faculty of Medicine, University of Bisha, Bisha, SAU
| | - Masoud M Alqahtani
- Department of Emergency Medicine, Faculty of Medicine, University of Bisha, Bisha, SAU
| | - Amaal M Almalki
- Department of Ophthalmology, King Abdulaziz Specialist Hospital, Taif, SAU
| | - Ashwaq Y Asiri
- Department of Ophthalmology, College of Medicine, King Khalid University, Abha, SAU
| |
Collapse
|
2
|
Bullimore MA, Jong M, Brennan NA. Myopia control: Seeing beyond efficacy. Optom Vis Sci 2024; 101:134-142. [PMID: 38546754 DOI: 10.1097/opx.0000000000002119] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 04/11/2024] Open
Abstract
SIGNIFICANCE The availability of a range of effective myopia control modalities enables the clinician to exercise judgment when discussing the treatment plan with the patient and their parents. This article outlines important considerations beyond efficacy.Clinically meaningful myopia control may be attained with some spectacle lenses, select soft contact lenses, some concentrations of atropine, and overnight orthokeratology. Given that satisfactory efficacy can be achieved with a range of modalities, other factors should be considered when deciding upon the best intervention for a given child. Four key factors-compliance, quality of vision, quality of life, and safety-are discussed in this review. Compliance directly impacts efficacy regardless of the modality and is the most important consideration, as it is influenced by quality of vision and comfort. Daily disposal myopia control contact lenses and overnight orthokeratology are generally associated with high compliance, provide better vision-related quality of life than spectacles, and carry a very low risk when used appropriately. A further benefit of overnight orthokeratology is the elimination of a need for optical correction during the day.
Collapse
|
3
|
Haworth K, Travis D, Leslie L, Fuller D, Pucker AD. Silicone hydrogel versus hydrogel soft contact lenses for differences in patient-reported eye comfort and safety. Cochrane Database Syst Rev 2023; 9:CD014791. [PMID: 37724689 PMCID: PMC10507745 DOI: 10.1002/14651858.cd014791.pub2] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 09/21/2023]
Abstract
BACKGROUND Ocular discomfort is the leading cause of permanent discontinuation of soft contact lens (SCL) wear. Silicone hydrogel and hydrogel materials are the two major categories of SCLs, with silicone hydrogel materials being newer and more breathable than hydrogel materials. Whether comfort is associated with SCL material is controversial despite numerous studies. Similarly, the difference between these materials in terms of safety outcomes (e.g. frequency of microbial keratitis) is unclear. OBJECTIVES To evaluate the comparative effectiveness and safety of silicone hydrogel compared with hydrogel SCLs on self-reported comfort, dry eye test results, and adverse events in SCL-wearing adults 18 years of age or older. SEARCH METHODS The Cochrane Eyes and Vision Information Specialist searched the electronic databases for randomized controlled trials (RCTs). There were no restrictions on language or date of publication. We searched the Cochrane Central Register of Controlled Trials (CENTRAL, including the Cochrane Eyes and Vision Trials Register; 2022, Issue 6), MEDLINE Ovid, Embase.com, PubMed, LILACS (Latin American and Caribbean Health Science Information database), ClinicalTrials.gov, and World Health Organization (WHO) International Clinical Trials Registry Platform (ICTRP). We also searched the reference lists of identified studies, review articles, and guidelines for information about relevant studies that may not have been identified by our search strategy. Furthermore, we contacted investigators regarding ongoing trials. The most recent database search was conducted on 24 June 2022. SELECTION CRITERIA Our search selection criteria included RCTs, quasi-RCTs, and cross-over RCTs. DATA COLLECTION AND ANALYSIS We applied standard Cochrane methodology. MAIN RESULTS We included seven parallel-group RCTs conducted in the USA, the UK, Australia, Germany, India, and Turkey. A total of 1371 participants were randomized. The duration of SCL wear ranged from one to 52 weeks. Study characteristics and risk of bias The median number of participants per trial was 120 (interquartile range: 51 to 314), and the average age ranged from 20.7 to 33.0 years. Women represented the majority of participants (range 55% to 74.9%; 5 RCTs). Collectively, the included trials compared eight different silicone hydrogel SCLs with three different hydrogel SCLs. Five trials compared daily disposable SCLs, and two compared extended wear SCLs (worn for seven days and six nights). New SCL wearers were enrolled in three trials. Two trials included both new and established SCL wearers, and two trials did not report participants' history of SCL use. Five trials were sponsored by industry. We judged the overall risk of bias to be 'high' or 'some concerns' for the safety and efficacy outcomes. Findings One trial reported Ocular Surface Disease Index (OSDI) results, with the evidence being very uncertain about the effects of SCL material on OSDI scores (mean difference -1.20, 95% confidence interval [CI] -10.49 to 8.09; 1 RCT, 47 participants; very low certainty evidence). Three trials reported visual analog scale comfort score results, with no clear difference in comfort between materials, but the evidence was of very low certainty; trial results could not be combined because the three trials reported results at different time points. The evidence is very uncertain about the effect of SCL material on discontinuation of contact lens wear (risk ratio [RR] 0.64, 95% CI 0.11 to 3.74; 1 RCT, 248 participants). None of the included trials reported Contact Lens Dry Eye Questionnaire (CLDEQ-8) or Standard Patient Evaluation of Eye Dryness (SPEED) scores. There was no evidence of a clinically meaningful difference (> 0.5 unit) between daily disposable silicone hydrogel and hydrogel SCLs in corneal staining, conjunctival staining, or conjunctival redness (very low certainty evidence). Adverse events Very low certainty evidence from two trials comparing daily disposable SCLs suggested no evidence of a difference between lens materials in the risk of vision-threatening adverse events at one to four weeks (RR 0.68, 95% CI 0.08 to 5.51; 2 RCTs, 368 participants). Two trials comparing extended wear SCLs indicated that hydrogel SCLs may have a 2.03 times lower risk of adverse events at 52 weeks compared with silicone hydrogel SCLs (RR 2.03, 95% CI 1.38 to 2.99; 815 participants), but the certainty of evidence was very low. AUTHORS' CONCLUSIONS The overall evidence for a difference between all included silicone hydrogel and hydrogel SCLs was of very low certainty, with most trials at high overall risk of bias. The majority of studies did not assess comfort using a validated instrument. There was insufficient evidence to support recommending one SCL material over the other. For extended wear, hydrogel SCL may have a lower risk of adverse events at 52 weeks compared to silicon hydrogel. Future well-designed trials are needed to generate high certainty evidence to further clarify differences in SCL material comfort and safety.
Collapse
Affiliation(s)
| | - Darian Travis
- School of Optometry, University of Alabama at Birmingham, Birmingham, Alabama, USA
| | - Louis Leslie
- Department of Ophthalmology, University of Colorado Anschutz Medical Campus, Aurora, Colorado, USA
| | - Daniel Fuller
- Cornea Contact Lens Service, The Eye Center, Southern College of Optometry, Memphis, TN, USA
| | - Andrew D Pucker
- School of Optometry, University of Alabama at Birmingham, Birmingham, Alabama, USA
| |
Collapse
|
4
|
Ishihara K, Shi X, Fukazawa K, Yamaoka T, Yao G, Wu JY. Biomimetic-Engineered Silicone Hydrogel Contact Lens Materials. ACS APPLIED BIO MATERIALS 2023; 6:3600-3616. [PMID: 37616500 PMCID: PMC10521029 DOI: 10.1021/acsabm.3c00296] [Citation(s) in RCA: 3] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/17/2023] [Accepted: 08/16/2023] [Indexed: 08/26/2023]
Abstract
Contact lenses are one of the most successful applications of biomaterials. The chemical structure of the polymers used in contact lenses plays an important role in determining the function of contact lenses. Different types of contact lenses have been developed based on the chemical structure of polymers. When designing contact lenses, materials scientists consider factors such as mechanical properties, processing properties, optical properties, histocompatibility, and antifouling properties, to ensure long-term wear with minimal discomfort. Advances in contact lens materials have addressed traditional issues such as oxygen permeability and biocompatibility, improving overall comfort, and duration of use. For example, silicone hydrogel contact lenses with high oxygen permeability were developed to extend the duration of use. In addition, controlling the surface properties of contact lenses in direct contact with the cornea tissue through surface polymer modification mimics the surface morphology of corneal tissue while maintaining the essential properties of the contact lens, a significant improvement for long-term use and reuse of contact lenses. This review presents the material science elements required for advanced contact lenses of the future and summarizes the chemical methods for achieving these goals.
Collapse
Affiliation(s)
- Kazuhiko Ishihara
- Division
of Materials and Manufacturing Science, Graduate School of Engineering, Osaka University, Suita, Osaka 565-0871, Japan
| | - Xinfeng Shi
- Alcon
Research, LLC, Fort Worth, Texas 76134, United States
| | - Kyoko Fukazawa
- National
Cerebral and Cardiovascular Center Research Institute, Suita, Osaka 564-8565, Japan
| | - Tetsuji Yamaoka
- National
Cerebral and Cardiovascular Center Research Institute, Suita, Osaka 564-8565, Japan
| | - George Yao
- Alcon
Research, LLC, Duluth, Georgia 30097, United States
| | | |
Collapse
|
5
|
Jones L, Efron N, Bandamwar K, Barnett M, Jacobs DS, Jalbert I, Pult H, Rhee MK, Sheardown H, Shovlin JP, Stahl U, Stanila A, Tan J, Tavazzi S, Ucakhan OO, Willcox MDP, Downie LE. TFOS Lifestyle: Impact of contact lenses on the ocular surface. Ocul Surf 2023; 29:175-219. [PMID: 37149139 DOI: 10.1016/j.jtos.2023.04.010] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/07/2023] [Accepted: 04/10/2023] [Indexed: 05/08/2023]
Abstract
Several lifestyle choices made by contact lens wearers can have adverse consequences on ocular health. These include being non-adherent to contact lens care, sleeping in lenses, ill-advised purchasing options, not seeing an eyecare professional for regular aftercare visits, wearing lenses when feeling unwell, wearing lenses too soon after various forms of ophthalmic surgery, and wearing lenses when engaged in risky behaviors (e.g., when using tobacco, alcohol or recreational drugs). Those with a pre-existing compromised ocular surface may find that contact lens wear exacerbates ocular disease morbidity. Conversely, contact lenses may have various therapeutic benefits. The coronavirus disease-2019 (COVID-19) pandemic impinged upon the lifestyle of contact lens wearers, introducing challenges such as mask-associated dry eye, contact lens discomfort with increased use of digital devices, inadvertent exposure to hand sanitizers, and reduced use of lenses. Wearing contact lenses in challenging environments, such as in the presence of dust and noxious chemicals, or where there is the possibility of ocular trauma (e.g., sport or working with tools) can be problematic, although in some instances lenses can be protective. Contact lenses can be worn for sport, theatre, at high altitude, driving at night, in the military and in space, and special considerations are required when prescribing in such situations to ensure successful outcomes. A systematic review and meta-analysis, incorporated within the review, identified that the influence of lifestyle factors on soft contact lens dropout remains poorly understood, and is an area in need of further research. Overall, this report investigated lifestyle-related choices made by clinicians and contact lens wearers and discovered that when appropriate lifestyle choices are made, contact lens wear can enhance the quality of life of wearers.
Collapse
Affiliation(s)
- Lyndon Jones
- Centre for Ocular Research & Education (CORE), School of Optometry and Vision Science, University of Waterloo, Waterloo, ON, Canada.
| | - Nathan Efron
- School of Optometry and Vision Science, Queensland University of Technology, Kelvin Grove, Queensland, Australia
| | - Kalika Bandamwar
- Department of Ophthalmology, New Zealand National Eye Centre, The University of Auckland, Auckland, New Zealand
| | - Melissa Barnett
- University of California, Davis Eye Center, Sacramento, CA, USA
| | - Deborah S Jacobs
- Massachusetts Eye & Ear, Harvard Medical School, Boston, MA, USA
| | - Isabelle Jalbert
- School of Optometry and Vision Science, UNSW Sydney, NSW, Australia
| | - Heiko Pult
- Dr Heiko Pult Optometry & Vision Research, Weinheim, Germany
| | | | - Heather Sheardown
- Department of Chemical Engineering, McMaster University, Hamilton, Ontario, Canada
| | | | - Ulli Stahl
- Centre for Ocular Research & Education (CORE), School of Optometry and Vision Science, University of Waterloo, Waterloo, ON, Canada
| | | | - Jacqueline Tan
- School of Optometry and Vision Science, UNSW Sydney, NSW, Australia
| | - Silvia Tavazzi
- Department of Materials Science, University of Milano-Bicocca, Milan, Italy
| | | | - Mark D P Willcox
- School of Optometry and Vision Science, UNSW Sydney, NSW, Australia
| | - Laura E Downie
- Department of Optometry and Vision Sciences, The University of Melbourne, Parkville, Victoria, Australia
| |
Collapse
|
6
|
Bullimore MA, Richdale K. Incidence of Corneal Adverse Events in Children Wearing Soft Contact Lenses. Eye Contact Lens 2023; 49:204-211. [PMID: 36877990 PMCID: PMC10503544 DOI: 10.1097/icl.0000000000000976] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Accepted: 01/14/2023] [Indexed: 03/08/2023]
Abstract
OBJECTIVES There is increasing interest in fitting children with soft contact lenses, in part due to the increase in prescribing of designs to slow the progression of myopia. This literature review summarizes large prospective and retrospective studies that include data on the incidence of microbial keratitis and corneal infiltrative events (CIEs) in children wearing soft contact lenses. METHODS Peer-reviewed prospective and retrospective studies that report contact lens-related complications in children with at least one year of wear and at least 100 patient years of wear were identified. RESULTS Seven prospective studies published between 2004 and 2022 were identified representing 3,752 patient years of wear in 1,756 children, nearly all of whom were fitted at age 12 years or younger. Collectively, they report one case of microbial keratitis and 53 CIEs, of which 16 were classified as symptomatic. The overall incidence of microbial keratitis was 2.7 per 10,000 patient years (95% CI: 0.5-15), and the incidence of symptomatic CIEs was 42 per 10,000 patient years (95% CI: 26-69). Two retrospective studies were identified representing 2,545 patient years of wear in 1,025 children, fitted at age 12 years or younger. One study reports two cases of microbial keratitis giving an incidence of 9.4 per 10,000 patient years (95% CI: 0.5-15). CONCLUSIONS Accurate classification of CIEs is challenging, particularly in retrospective studies. The incidence of microbial keratitis in children wearing soft lenses is no higher than in adults, and the incidence of CIEs seems to be markedly lower.
Collapse
|
7
|
Lutmer KM, Wagner H, Richdale K, Zimmerman AB, Datta A, Dougherty BE. Examining daily disposable soft contact lens wearers' attitudes and beliefs using the Health Belief Model. Ophthalmic Physiol Opt 2023; 43:202-211. [PMID: 36464862 PMCID: PMC10823430 DOI: 10.1111/opo.13078] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/05/2022] [Accepted: 11/21/2022] [Indexed: 12/11/2022]
Abstract
PURPOSE To use the Health Belief Model (HBM) to understand daily disposable (DD) soft contact lens (SCL) wearers' attitudes and beliefs. METHODS A convenience sample of DD SCL wearers (18-33 years) was enrolled at two sites. Participants were queried about demographics, SCL wear and HBM constructs. Rasch analysis was used to assess the psychometric properties of the survey instrument and generate scores for each HBM subscale. ANOVA was used to determine relationships among HBM constructs, subject demographics and DD SCL-related health behaviours. RESULTS One hundred people participated (mean ± SD), age = 24.2 ± 3.9 years, 76% female. Thirty-seven percent reported sleeping in DD SCLs and 25% reported reusing DD SCLs. Self-report of reusing DD SCLs was associated with scores on the benefits: reuse (p = 0.02) and barriers (p = 0.007) subscales, and sleeping in lenses was associated with scores on the susceptibility (p = 0.05), benefits: wear behaviours (p = 0.006) and barriers (p = 0.01) subscales. Rasch analysis showed some subscales demonstrated multidimensionality. CONCLUSIONS Selected health belief constructs were associated with DD SCL-related behaviours including reusing and overnight wear. Increased understanding of SCL attitudes and beliefs could inform patient education and interventions to decrease risks associated with improper SCL wear.
Collapse
Affiliation(s)
- Kelly M. Lutmer
- College of Optometry, The Ohio State University, Columbus, Ohio, USA
| | - Heidi Wagner
- College of Optometry, The Ohio State University, Columbus, Ohio, USA
| | - Kathryn Richdale
- College of Optometry, University of Houston, Houston, Texas, USA
| | | | - Ananya Datta
- College of Optometry, University of Houston, Houston, Texas, USA
| | | |
Collapse
|
8
|
Corneal Confocal Analysis after Scleral Lens Wear in Keratoconus Patients: A Pilot Study. Optom Vis Sci 2022; 99:800-806. [PMID: 36301598 DOI: 10.1097/opx.0000000000001954] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/06/2023] Open
Abstract
SIGNIFICANCE Scleral lenses rely on the scleroconjunctival region without bearing the cornea, which could improve the symptoms and modify the corneal nerve plexus morphology. PURPOSE This study aimed to evaluate symptoms and changes in corneal nerve plexus morphology and density of Langerhans cells in keratoconus patients with and without intrastromal corneal ring before and after scleral lens wear. METHODS Sixteen scleral lens wearers with keratoconus were recruited for this short-term experimental pilot study. Subjects were divided into two groups: keratoconus group and intrastromal corneal ring segment group. All subjects were examined in two visits: baseline (before scleral lens wear) and after 6 months of scleral lens wear, after lens removal. The Schirmer I test, the Ocular Surface Disease Index, tear breakup time, and in vivo confocal microscopy were evaluated. RESULTS The mean age was 42.33 ± 11.27 years. A significant decrease in tear breakup time was found in the total group ( P = .01, Wilcoxon) compared with baseline. Ocular Surface Disease Index score had decreased after 6 months of scleral lens wear in the keratoconus with intrastromal corneal ring segment subgroup ( P = .03, Wilcoxon) and in the total group ( P = .001, Wilcoxon). No statistical changes in nerve density, tortuosity, and ramification were found for either the total group or the subgroup. However, the mean nerve length was higher in all groups, especially in the keratoconus subgroup ( P = .03, Wilcoxon) after 6 months of scleral lens wear. Regarding optical density, the total group showed a significant increase after 6 months of wearing ( P = .02, Wilcoxon). Finally, Langerhans cell density was not statistically different in any group. CONCLUSIONS These results suggest that scleral lens wearing improves the symptoms and increased the mean length nerves after 6 months of wear use in keratoconus patients.
Collapse
|
9
|
Abstract
ABSTRACT Contact lenses are a safe and effective method for correction of refractive error and worn by an estimated 45 million Americans. Because of the widespread availability and commercial popularity of contact lenses, it is not well appreciated by the public that contact lenses are U.S. Food and Drug Administration (FDA)-regulated medical devices. Contact lenses are marketed in numerous hard and soft materials that have been improved over decades, worn in daily or extended wear, and replaced in range of schedules from daily to yearly or longer. Lens materials and wear and care regimens have impact on the risks of contact lens-related corneal inflammatory events and microbial keratitis. This article reviews contact lens safety, with specific focus on the correction of refractive error in healthy eyes.
Collapse
|
10
|
Walsh K, Jones L, Moody K. Addressing common myths and misconceptions in soft contact lens practice. Clin Exp Optom 2021; 105:459-473. [PMID: 34886744 DOI: 10.1080/08164622.2021.2003693] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/19/2022] Open
Abstract
Advances in contact lens technology over the past 50 years since the commercialisation of the first soft lenses in 1971 have been incredible, with significant changes in contact lens materials, frequency of replacement, care systems and lens designs occurring. However, despite the widespread availability of contact lenses, penetration rates for those who need vision correction remain in the low single digits and many practitioners seem to hold on to concepts around the potential value of contact lenses that appear based in the dim and distant past and are certainly no longer valid today. This review addresses 10 common 'myths and misconceptions' around soft contact lenses using an evidence-based approach that can hopefully dispel some of these incorrect assumptions.
Collapse
Affiliation(s)
- Karen Walsh
- Centre for Ocular Research & Education (CORE), School of Optometry and Vision Science, University of Waterloo, Waterloo, Canada
| | - Lyndon Jones
- Centre for Ocular Research & Education (CORE), School of Optometry and Vision Science, University of Waterloo, Waterloo, Canada.,Centre for Eye and Vision Research (CEVR), 17W Hong Kong Science Park, Shatin, Hong Kong
| | - Kurt Moody
- Johnson & Johnson Vision, Jacksonville, Florida, USA
| |
Collapse
|
11
|
Tahhan N, Naduvilath TJ, Woods C, Papas E. Review of 20 years of soft contact lens wearer ocular physiology data. Cont Lens Anterior Eye 2021; 45:101525. [PMID: 34686430 DOI: 10.1016/j.clae.2021.101525] [Citation(s) in RCA: 6] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/26/2021] [Revised: 09/29/2021] [Accepted: 10/05/2021] [Indexed: 12/22/2022]
Abstract
BACKGROUND Since the introduction of Silicone hydrogel (SiHy) contact lenses 20 years ago, industry has continued to modify lens materials, designs, lens care products and manufacturing processes, striving to improve contact lens physiological performance, comfort, and convenience for wearers. The purpose of this study was to investigate whether the ocular health of habitual soft contact lens wearers today is better than it was in previous decades. METHODS Baseline ocular physiology data for 3624 participants from a The Brien Holden Vision Institute clinical trials database were retrospectively reviewed. Records were grouped into 3 time periods; A: >2 decades ago (1997-1999), B: one decade ago (2009-2014) and C: recent years (since 2015). Physiology data for both neophytes and habitual contact lens wearers included; bulbar, limbal and upper palpebral conjunctival redness, corneal and conjunctival staining and conjunctival indentation from contact lenses. RESULTS Corneal staining levels are similar between neophytes and contact lens wearers at time points A and C but worse for contact lens wearers at time point B. Limbal redness was greater in contact lens wearers than in neophytes at time point A but at time points B and C they are not different to the non-contact lens wearing population. In recent years, most ocular physiological variables in habitual contact lens wearers are similar to neophytes. CONCLUSIONS While there have been changes over the past two decades in ocular physiological responses to contact lens wear, it appears that ocular health with current day contact lens wear is similar to no lens wear in most respects.
Collapse
Affiliation(s)
- Nina Tahhan
- Brien Holden Vision Institute, Sydney, New South Wales, Australia; School of Optometry and Vision Science, University of New South Wales, Sydney, New South Wales, Australia.
| | | | - Craig Woods
- Brien Holden Vision Institute, Sydney, New South Wales, Australia; School of Optometry and Vision Science, University of New South Wales, Sydney, New South Wales, Australia
| | - Eric Papas
- School of Optometry and Vision Science, University of New South Wales, Sydney, New South Wales, Australia
| |
Collapse
|
12
|
Saliman NH, Maldonado-Codina C, Morgan PB. Effect of material and care system combination on subclinical inflammation of the ocular surface in soft contact lens wear. Cont Lens Anterior Eye 2021; 45:101489. [PMID: 34281726 DOI: 10.1016/j.clae.2021.101489] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/04/2021] [Revised: 07/03/2021] [Accepted: 07/07/2021] [Indexed: 12/20/2022]
Abstract
PURPOSE To investigate the ocular subclinical inflammatory response in two soft contact lens materials when used in combination with two different care systems ('solutions'). METHODS Fifteen established soft contact lens wearers wore each of two lenses: Acuvue® 2 (CH) and Acuvue® Oasys® (SiH) or no lenses in random sequence for one week. Two care systems were used: a peroxide system: Oxysept 1 Step® (P) for the right lens and Opti-Free® Replenish® (MPS) for the left lens. After one week of lens/no lens wear, in vivo confocal microscopy (IVCM) of corneal and conjunctival regions was carried out. Density of presumed dendritic cells (DC) and 'white spots' (WS) were quantified. Impression cytology of the bulbar and upper eyelid margin conjunctivae was carried out and samples were analysed for CD45+, CD3+ and CD11c+ cells. RESULTS The SiH + MPS combination showed a greater inflammatory response compared to SiH + P in seven out of 12 parameters investigated (p < 0.05). The remaining five were not statistically different between the two solutions. The converse was found for the CH lens, with four of the 12 parameters showing a greater response with the P solution compared to the MPS (p < 0.05). CONCLUSION This study suggests that the SiH lens investigated demonstrated an upregulated response when used with a MPS compared to a P solution whereas the converse is true for the CH lens which showed a reduced response when used with a MPS compared to a P solution. This finding aids in the understanding of the biological underpinnings of manifest corneal inflammatory events during contact lens wear.
Collapse
Affiliation(s)
- Noor Haziq Saliman
- Eurolens Research, Division of Pharmacy and Optometry, Faculty of Biology, Medicine and Health, The University of Manchester, Manchester, United Kingdom; Neuroscience and Ophthalmology, Institute of Inflammation and Ageing, College of Medical and Dental Sciences, University of Birmingham, Birmingham, United Kingdom; NIHR Surgical Reconstruction and Microbiology Research Centre, University Hospitals Birmingham NHS Foundation Trust, Birmingham, United Kingdom.
| | - Carole Maldonado-Codina
- Eurolens Research, Division of Pharmacy and Optometry, Faculty of Biology, Medicine and Health, The University of Manchester, Manchester, United Kingdom
| | - Philip B Morgan
- Eurolens Research, Division of Pharmacy and Optometry, Faculty of Biology, Medicine and Health, The University of Manchester, Manchester, United Kingdom
| |
Collapse
|
13
|
Kalaiselvan P, Konda N, Pampi N, Vaddavalli PK, Sharma S, Stapleton F, Kumar N, Willcox MDP, Dutta D. Effect of Antimicrobial Contact Lenses on Corneal Infiltrative Events: A Randomized Clinical Trial. Transl Vis Sci Technol 2021; 10:32. [PMID: 34191016 PMCID: PMC8254012 DOI: 10.1167/tvst.10.7.32] [Citation(s) in RCA: 9] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/24/2022] Open
Abstract
Purpose To determine whether Mel4-coated antimicrobial contact lenses (MACLs) can reduce the incidence of corneal infiltrative events (CIEs) during extended wear. Methods A prospective, randomized, double-masked, single-center, contralateral, extended contact lens wear clinical trial was conducted with 176 subjects. Each participant was randomly assigned to wear a MACL in one eye and an uncoated control contact lens in the contralateral eye or an extended-wear biweekly disposable modality for 3 months. The main outcome measures were the incidence of CIEs per 100 eye-months, identification of the microbial types colonizing the contact lenses or eyes at the time of the CIEs, and their susceptibility to Mel4. Results Nine participants (5.1%) experienced unilateral CIEs; six participants had contact lens acute red eye, and three participants had infiltrative keratitis. The incidence rate for CIEs (0.4 events per 100 participant months; 1.7%) in the Mel4-coated lenses (test) was 69% less than that of the control lenses (1.3 events per 100 participant months; 3.4%; P = 0.29). All Gram-negative bacteria isolated from lenses and lids of participants with CIEs (Citrobacter diversus, Acinetobacter haemolyticus, and Acinetobacter lwoffii) were susceptible to Mel4 peptide; minimum inhibitory concentrations ranged from 15.6 to 62.5 µg/mL. Reduction of adhesion of these bacteria by Mel4-coated lenses ranged from 2.1 to 2.2 log10 colony-forming units/lens. Conclusions MACLs had the capacity to reduce CIEs by at least 50% compared with uncoated control lenses during extended wear over 3 months; however, due to the relatively low rates of CIEs, the reduction was not statistically different compared with control lenses. Translational Relevance This study provides evidence that antimicrobial contact lenses have the potential to reduce the incidence of corneal infiltrative events during extended wear.
Collapse
Affiliation(s)
| | - Nagaraju Konda
- School of Medical Sciences, University of Hyderabad, Hyderabad, India
| | - Nending Pampi
- Bausch & Lomb Contact Lens Centre, L V Prasad Eye Institute, Hyderabad, India
| | - Pravin Krishna Vaddavalli
- Bausch & Lomb Contact Lens Centre, L V Prasad Eye Institute, Hyderabad, India.,The Cornea Institute, L V Prasad Eye Institute, Hyderabad, India
| | - Savitri Sharma
- Jhaveri Microbiology Centre, L V Prasad Eye Institute, Hyderabad, India
| | - Fiona Stapleton
- School of Optometry and Vision Science, University of New South Wales, Sydney, Australia
| | - Naresh Kumar
- School of Chemistry, University of New South Wales, Sydney, Australia
| | - Mark D P Willcox
- School of Optometry and Vision Science, University of New South Wales, Sydney, Australia
| | - Debarun Dutta
- School of Optometry and Vision Science, University of New South Wales, Sydney, Australia.,School of Optometry, Aston University, Birmingham, UK
| |
Collapse
|
14
|
Zhu D, Liu Y, Gilbert JL. Micromechanical measurement of adhesion of dehydrating silicone hydrogel contact lenses to corneal tissue. Acta Biomater 2021; 127:242-251. [PMID: 33812075 DOI: 10.1016/j.actbio.2021.03.053] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/02/2020] [Revised: 03/19/2021] [Accepted: 03/23/2021] [Indexed: 10/21/2022]
Abstract
Adhesion properties, which can vary with multiple factors, of silicone hydrogel contact lenses are important to their performance and comfort in the eye. In this study, we developed and used a simple, representative testing system and method to study the adhesive interactions of different silicone contact lenses (balafilcon A and senofilcon A) on polished titanium alloy and porcine whole eye cornea under dehydrating conditions. Adhesive interactions for senofilcon A varied by hydration state for both corneal and titanium adhesion, starting low, rising to a maximum and falling with dehydration time and dehydration state. Balafilcon A showed a rise and fall against titanium, but retained a relatively constant adhesive interaction with corneal tissue over dehydration time. Senofilcon A reached the highest adhesion forces (400 mN) within 5 to 10 min of testing against cornea, then dropped with time after that. Johnson-Kendall-Roberts (JKR) theory was applied to determine the surface energy of the lenses, and work of adhesion (WOA) was also determined for both lenses. Similar trends as observed with the force-hydration curves were seen with surface energy and work of adhesion as well (peak surface energy of 8 N/m and work of adhesion of 80 µJ for senofilcon A). Video imaging of the adhesive interactions showed significant corneal deformation taking place during testing, and post-test analysis shows damage to the corneal tissue. This method could be used to assess pre-clinical performance of long-lasting contact lenses and the role of hydration state. STATEMENT OF SIGNIFICANCE: Adhesion properties of contact lenses play significant roles in their performance and comfort in the eye. Adhesion is influenced by polymer chemistry, counterface materials and hydration state of the contact lenses. However, no test method has been developed to directly study the adhesion properties between contact lenses and corneal tissue during the dehydration process. Our work aims to fill this gap by developing testing and analysis methods for evaluating the adhesive interactions in vitro between contact lenses of different chemistries and properties and different counter surfaces under dehydrating conditions over time. Our study shows that adhesive interactions of contact lenses are highly dependent on polymer type, surface treatment, counterface material and hydration state.
Collapse
|
15
|
Ozek D, Karaca EE, Kazanci B, Evren Kemer O. Evaluation of Corneal Densitometry and Endothelial Layer in Soft Contact Lens Users. Optom Vis Sci 2021; 98:592-596. [PMID: 34081651 DOI: 10.1097/opx.0000000000001707] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/26/2022] Open
Abstract
SIGNIFICANCE Soft contact lens wear may lead to physiological changes in the cornea. Corneal densitometry is a new software tool that may detect these physiological changes by monitoring their effects on corneal transparency. PURPOSE This study aimed to assess corneal densitometry values and corneal endothelium in patients using soft contact lenses. METHODS The study included 36 eyes of 36 subjects with soft contact lens use (group 1) and 36 eyes of 36 healthy control subjects (group 2). Anterior segment parameters and corneal densitometry of all subjects were evaluated using Scheimpflug corneal topography (Pentacam; Oculus Inc., Wetzlar, Germany). A total corneal area of 12 mm was divided into four annular zones (0 to 2, 2 to 6, 6 to 10, and 10 to 12 mm) and into three regions as anterior, central, and posterior for densitometry examination. Cell density, cell distribution, and cell morphology (quadrangular, pentagonal, hexagonal, and other cell percentages) of the endothelial layer were examined in both groups using specular microscopy (Nidek CEM 530; Nidek Co., Gamagori, Aichi, Japan). RESULTS In group 1, the mean duration of contact lens wear was 4.45 ± 2.15 years. The anterior segment parameters were not significantly different between the two groups (P > .05). The anterior 0- to 2- and 2- to 6-mm corneal densitometry values were significantly higher in group 1 compared with group 2 (23.2 ± 4.7 for group 1 and 17.3 ± 5.6 for group 2 [P = .03]; 22.4 ± 6.4 for group 1 and 17.8 ± 1.4 for group 2 [P = .03], respectively). There were no significant differences between the groups for corneal densitometry values between 6 and 12 mm, or for cell density, cell distribution, and cell morphology (P > .05). CONCLUSIONS Although the cornea remains transparent in soft contact lens wearers, corneal densitometry may increase in the 0- to 6-mm annular zone of the anterior region.
Collapse
Affiliation(s)
| | | | - Burcu Kazanci
- Department of Ophthalmology, Ulucanlar Training and Research Hospital, Ankara, Turkey
| | - Ozlem Evren Kemer
- Department of Ophthalmology, Ulucanlar Training and Research Hospital, Ankara, Turkey
| |
Collapse
|
16
|
Bullimore MA, Ritchey ER, Shah S, Leveziel N, Bourne RRA, Flitcroft DI. The Risks and Benefits of Myopia Control. Ophthalmology 2021; 128:1561-1579. [PMID: 33961969 DOI: 10.1016/j.ophtha.2021.04.032] [Citation(s) in RCA: 72] [Impact Index Per Article: 24.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/22/2020] [Revised: 04/27/2021] [Accepted: 04/28/2021] [Indexed: 02/09/2023] Open
Abstract
PURPOSE The prevalence of myopia is increasing around the world, stimulating interest in methods to slow its progression. The primary justification for slowing myopia progression is to reduce the risk of vision loss through sight-threatening ocular pathologic features in later life. The article analyzes whether the potential benefits of slowing myopia progression by 1 diopter (D) justify the potential risks associated with treatments. METHODS First, the known risks associated with various methods of myopia control are summarized, with emphasis on contact lens wear. Based on available data, the risk of visual impairment and predicted years of visual impairment are estimated for a range of incidence levels. Next, the increased risk of potentially sight-threatening conditions associated with different levels of myopia are reviewed. Finally, a model of the risk of visual impairment as a function of myopia level is developed, and the years of visual impairment associated with various levels of myopia and the years of visual impairment that could be prevented with achievable levels of myopia control are estimated. RESULTS Assuming an incidence of microbial keratitis between 1 and 25 per 10 000 patient-years and that 15% of cases result in vision loss leads to the conclusion that between 38 and 945 patients need to be exposed to 5 years of wear to produce 5 years of vision loss. Each additional 1 D of myopia is associated with a 58%, 20%, 21%, and 30% increase in the risk of myopic maculopathy, open-angle glaucoma, posterior subcapsular cataract, and retinal detachment, respectively. The predicted mean years of visual impairment ranges from 4.42 in a person with myopia of -3 D to 9.56 in a person with myopia of -8 D, and a 1-D reduction would lower these by 0.74 and 1.21 years, respectively. CONCLUSIONS The potential benefits of myopia control outweigh the risks: the number needed to treat to prevent 5 years of visual impairment is between 4.1 and 6.8, whereas fewer than 1 in 38 will experience a loss of vision as a result of myopia control.
Collapse
Affiliation(s)
| | - Eric R Ritchey
- College of Optometry, University of Houston, Houston, Texas
| | - Sunil Shah
- Birmingham and Midland Eye Centre, Birmingham, United Kingdom; Ophthalmic and Vision Sciences Research Group, Life and Health Sciences, Aston University, Birmingham, United Kingdom
| | - Nicolas Leveziel
- Service d'ophtalmologie, Centre Hospitalier Universitaire (CHU) Poitiers, Poitiers, France; University of Poitiers, Poitiers, France; Centre d'Investigation Clinique (CIC 1402), Poitiers, France; Institut National de la Santé et de la Recherche Médicale (INSERM 1084), Poitiers, France; Vision & Eye Research Institute, School of Medicine, Anglia Ruskin University, Cambridge, United Kingdom
| | - Rupert R A Bourne
- Vision & Eye Research Institute, School of Medicine, Anglia Ruskin University, Cambridge, United Kingdom; Department of Ophthalmology, Cambridge University Hospital, Cambridge, United Kingdom
| | - D Ian Flitcroft
- Department of Ophthalmology, Children's University Hospital, Dublin, Ireland; Centre for Eye Research Ireland, School of Physics, Clinical and Optometric Sciences, Technological University Dublin, Dublin, Ireland
| |
Collapse
|
17
|
Efron N, Morgan PB. Are hypoxia or modulus causes of contact lens‐associated keratitis? Clin Exp Optom 2021; 92:329-30. [DOI: 10.1111/j.1444-0938.2009.00381.x] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/30/2022] Open
|
18
|
CLEAR - Contact lens wettability, cleaning, disinfection and interactions with tears. Cont Lens Anterior Eye 2021; 44:157-191. [DOI: 10.1016/j.clae.2021.02.004] [Citation(s) in RCA: 24] [Impact Index Per Article: 8.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/26/2021] [Accepted: 02/01/2021] [Indexed: 12/15/2022]
|
19
|
Mirzapour P, McCanna DJ, Jones L. In vitro analysis of the interaction of tear film inflammatory markers with contemporary contact lens materials. Cont Lens Anterior Eye 2021; 44:101430. [PMID: 33771440 DOI: 10.1016/j.clae.2021.02.016] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/31/2020] [Revised: 02/01/2021] [Accepted: 02/12/2021] [Indexed: 11/17/2022]
Abstract
PURPOSE Several clinical studies have suggested that reusable silicone hydrogel contact lens materials exhibit a two-times increased rate of corneal infiltrative events compared to reusable hydrogels. One potential factor contributing to this complication relates to the differential uptake of tear film-based pro-inflammatory cytokines. The purpose of this study was to use an in vitro assay to investigate whether four pro-inflammatory cytokines differed in their uptake onto six contemporary contact lens materials. METHODS Conventional hydrogel (etafilcon A, omafilcon A) and silicone hydrogel (balafilcon A, comfilcon A, senofilcon A, somofilcon A) contact lens materials were soaked in solutions containing pro-inflammatory cytokines IL-1β, IL-6, IL-8 and TNF-α. Samples of the soaking solutions were collected over various time points and analyzed using the Meso Scale Discovery system, which served as a measurement of cytokine uptake onto the contact lens materials. RESULTS Both conventional hydrogels (etafilcon A, omafilcon A) and two of the four silicone hydrogels tested (balafilcon A, comfilcon A), exhibited some uptake of IL-1β, IL-8 or TNF-α (p < 0.05). Senofilcon A and somofilcon A did not exhibit uptake of any of these cytokines (p > 0.05). There was no uptake of IL-6 onto any of the contact lens materials investigated (p > 0.05). CONCLUSION The contact lens materials tested did not exhibit any uptake of IL-6 and furthermore, did not exhibit more than 10 ± 3 % to 25 ± 12 % uptake of IL-1β, IL-8 or TNF-α. Numerous factors could contribute to the reported increase in corneal infiltrative events with reusable silicone hydrogel materials, however, based on these results, it appears that uptake of these four cytokines are unlikely to contribute to this finding.
Collapse
Affiliation(s)
- Parisa Mirzapour
- Centre for Ocular Research & Education (CORE), School of Optometry & Vision Science, University of Waterloo, 200 University Avenue West, Waterloo, Ontario N2L 3G1, Canada.
| | - David J McCanna
- Centre for Ocular Research & Education (CORE), School of Optometry & Vision Science, University of Waterloo, 200 University Avenue West, Waterloo, Ontario N2L 3G1, Canada
| | - Lyndon Jones
- Centre for Ocular Research & Education (CORE), School of Optometry & Vision Science, University of Waterloo, 200 University Avenue West, Waterloo, Ontario N2L 3G1, Canada; Centre for Eye & Vision Research (CEVR), 17W Hong Kong Science Park, Hong Kong
| |
Collapse
|
20
|
Ho L, Jalbert I, Watt K, Hui A. Current understanding and therapeutic management of contact lens associated sterile corneal infiltrates and microbial keratitis. Clin Exp Optom 2021; 104:323-333. [PMID: 33689618 DOI: 10.1080/08164622.2021.1877530] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/22/2022] Open
Abstract
Contact lenses are widely prescribed in clinical practice with multiple applications and advantages. However, contact lenses can be associated with various complications which range from innocuous to severe. Clinicians thus not only need to possess the ability to prescribe the most appropriate contact lenses for each individual patient but also be able to recognise and manage any associated complications. This review examines the existing literature on the management of corneal infiltrative events associated with soft contact lenses, including microbial keratitis, particularly in the context of practising in Australia. The definitions and diagnosis of corneal infiltrative events, as well as the current understanding of their aetiologies, will be explored. The various aspects of a successful management will be discussed, including the applications of therapeutic agents such as antimicrobial and anti-inflammatory agents, the role of microbiological investigations, and strategies to improve long-term prognosis. The currently available evidence supporting management options will be presented, highlighting the relative abundance of high-level evidence on management protocols, antimicrobial selection and treatment duration for microbial keratitis; and the relative paucity of studies and trials for sterile corneal infiltrative events, despite this condition being much more commonly encountered in clinical practice.
Collapse
Affiliation(s)
- Lily Ho
- School of Optometry and Vision Science, UNSW Sydney, Sydney, NSW, Australia
| | - Isabelle Jalbert
- School of Optometry and Vision Science, UNSW Sydney, Sydney, NSW, Australia
| | - Kathleen Watt
- School of Optometry and Vision Science, UNSW Sydney, Sydney, NSW, Australia
| | - Alex Hui
- School of Optometry and Vision Science, UNSW Sydney, Sydney, NSW, Australia
| |
Collapse
|
21
|
Szczotka-Flynn LB, Shovlin JP, Schnider CM, Caffery BE, Alfonso EC, Carnt NA, Chalmers RL, Collier S, Jacobs DS, Joslin CE, Kroken AR, Lakkis C, Pearlman E, Schein OD, Stapleton F, Tu E, Willcox MDP. American Academy of Optometry Microbial Keratitis Think Tank. Optom Vis Sci 2021; 98:182-198. [PMID: 33771951 PMCID: PMC8075116 DOI: 10.1097/opx.0000000000001664] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/29/2022] Open
Abstract
SIGNIFICANCE Think Tank 2019 affirmed that the rate of infection associated with contact lenses has not changed in several decades. Also, there is a trend toward more serious infections associated with Acanthamoeba and fungi. The growing use of contact lenses in children demands our attention with surveillance and case-control studies. PURPOSE The American Academy of Optometry (AAO) gathered researchers and key opinion leaders from around the world to discuss contact lens-associated microbial keratitis at the 2019 AAO Annual Meeting. METHODS Experts presented within four sessions. Session 1 covered the epidemiology of microbial keratitis, pathogenesis of Pseudomonas aeruginosa, and the role of lens care systems and storage cases in corneal disease. Session 2 covered nonbacterial forms of keratitis in contact lens wearers. Session 3 covered future needs, challenges, and research questions in relation to microbial keratitis in youth and myopia control, microbiome, antimicrobial surfaces, and genetic susceptibility. Session 4 covered compliance and communication imperatives. RESULTS The absolute rate of microbial keratitis has remained very consistent for three decades despite new technologies, and extended wear significantly increases the risk. Improved oxygen delivery afforded by silicone hydrogel lenses has not impacted the rates, and although the introduction of daily disposable lenses has minimized the risk of severe disease, there is no consistent evidence that they have altered the overall rate of microbial keratitis. Overnight orthokeratology lenses may increase the risk of microbial keratitis, especially secondary to Acanthamoeba, in children. Compliance remains a concern and a significant risk factor for disease. New insights into host microbiome and genetic susceptibility may uncover new theories. More studies such as case-control designs suited for rare diseases and registries are needed. CONCLUSIONS The first annual AAO Think Tank acknowledged that the risk of microbial keratitis has not decreased over decades, despite innovation. Important questions and research directions remain.
Collapse
Affiliation(s)
| | | | | | | | - Eduardo C Alfonso
- Bascom Palmer Eye Institute, University of Miami Miller School of Medicine, Miami, Florida
| | - Nicole A Carnt
- School of Optometry and Vision Science, University of New South Wales, Sydney, New South Wales, Australia
| | | | - Sarah Collier
- U.S. Centers for Disease Control and Prevention, Atlanta, Georgia
| | - Deborah S Jacobs
- Massachusetts Eye and Ear, Cornea Service, Harvard Medical School, Boston, Massachusetts
| | - Charlotte E Joslin
- Department of Ophthalmology and Visual Science, College of Medicine, Division of Epidemiology and Biostatistics, School of Public Health, University of Illinois at Chicago, Chicago, Illinois
| | - Abby R Kroken
- School of Optometry, University of California, Berkeley, Berkeley, California
| | | | - Eric Pearlman
- Departments of Ophthalmology, and Physiology and Biophysics, University of California, Irvine, Irvine, California
| | - Oliver D Schein
- Wilmer Eye Institute, Johns Hopkins University School of Medicine, Baltimore, Maryland
| | - Fiona Stapleton
- School of Optometry and Vision Science, University of New South Wales, Sydney, New South Wales, Australia
| | - Elmer Tu
- University of Illinois Eye and Ear Infirmary, Chicago, Illinois
| | - Mark D P Willcox
- School of Optometry and Vision Science, University of New South Wales, Sydney, New South Wales, Australia
| |
Collapse
|
22
|
Woods J, Jones D, Jones L, Jones S, Hunt C, Chamberlain P, McNally J. Ocular health of children wearing daily disposable contact lenses over a 6-year period. Cont Lens Anterior Eye 2021; 44:101391. [DOI: 10.1016/j.clae.2020.11.011] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/30/2020] [Revised: 10/29/2020] [Accepted: 11/22/2020] [Indexed: 12/26/2022]
|
23
|
Mitchell GL, Richdale K, Lam D, Wagner H, Kinoshita BT, Zimmerman AB, Sorbara L, Rosner B. Development of a contact Lens risk survey. Cont Lens Anterior Eye 2020; 44:101383. [PMID: 33281075 DOI: 10.1016/j.clae.2020.11.003] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/24/2020] [Revised: 10/29/2020] [Accepted: 11/09/2020] [Indexed: 11/18/2022]
Abstract
PURPOSE To describe the development and report psychometric properties of the Contact Lens Risk Survey (CLRS) to identify patients at risk for soft contact lens-related complications. METHODS Psychometric properties of the CLRS, a web-based survey with branching logic, were determined using data from 5 multi-site fieldings (n = 1059), including re-fielding to sub groups. Responses from participants with and without an active red eye were used to identify risk factors of a red eye event and calculate an overall risk score. A 6th fielding of the CLRS (n = 171) was used to assess discriminate validity. RESULTS Participants needed 11-12 min to complete the survey with a negligible difference by age. Internal consistency was excellent (Cronbach's α ≥ 0.70) for 3 of the 5 constructs identified by factor analysis. Twelve of the 17 survey items exhibited excellent within-subject repeatability (Kappa ≥ 0.61). Between-subject agreement, assessed in 18-25 year olds, was high for the majority of items, suggesting good generalizability across different populations of SCL wearers. The ability of the model using individual items of the CLRS to discriminate Controls and participants with a red eye was good with an area under the curve of 0.779. CONCLUSION The CLRS tool is a repeatable and valid instrument to standardize documentation of demographic, behavior, and exposure factors which appear to drive the greatest risk of a contact lens related red eye event.
Collapse
Affiliation(s)
- G Lynn Mitchell
- Ohio State University, College of Optometry, Columbus, OH, United States.
| | - Kathryn Richdale
- University of Houston, College of Optometry, Houston, TX, United States
| | - Dawn Lam
- Marshall B. Ketchum University, College of Optometry, Fullerton, CA, United States
| | - Heidi Wagner
- Ohio State University, College of Optometry, Columbus, OH, United States
| | - Beth T Kinoshita
- Pacific University, College of Optometry, Forest Grove, OR, United States
| | - Aaron B Zimmerman
- Ohio State University, College of Optometry, Columbus, OH, United States
| | - Luigina Sorbara
- University of Waterloo, School of Optometry, Waterloo, ON, Canada
| | - Bernard Rosner
- Harvard University, T. H Chan School of Public Health, Boston, MA, United States
| |
Collapse
|
24
|
Saez-Martinez V, Mann A, Lydon F, Molock F, Layton SA, Toolan DTW, Howse JR, Topham PD, Tighe BJ. The influence of structure and morphology on ion permeation in commercial silicone hydrogel contact lenses. J Biomed Mater Res B Appl Biomater 2020; 109:137-148. [PMID: 32710466 DOI: 10.1002/jbm.b.34689] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/06/2020] [Revised: 06/06/2020] [Accepted: 07/02/2020] [Indexed: 11/11/2022]
Abstract
The importance of the microstzructure of silicone hydrogels is widely appreciated but is poorly understood and minimally investigated. To ensure comfort and eye health, these materials must simultaneously exhibit both high oxygen and high water permeability. In contrast with most conventional hydrogels, the water content and water structuring within silicone hydrogels cannot be solely used to predict permeability. The materials achieve these opposing requirements based on a composite of nanoscale domains of oxygen-permeable (silicone) and water-permeable hydrophilic components. This study correlated characteristic ion permeation coefficients of a selection of commercially available silicone hydrogel contact lenses with their morphological structure and chemical composition. Differential scanning calorimetry measured the water structuring properties through subdivision of the freezing water component into polymer-associated water (loosely bound to the polymer matrix) and ice-like water (unimpeded with a melting point close to that of pure water). Small-angle x-ray scattering, and environmental scanning electron microscopy techniques were used to investigate the structural morphology of the materials over a range of length scales. Significant, and previously unrecognized, differences in morphology between individual materials at nanometer length scales were determined; this will aid the design and performance of the next generation of ocular biomaterials, capable of maintaining ocular homeostasis.
Collapse
Affiliation(s)
- Virginia Saez-Martinez
- Biomaterials Research Unit, Chemical Engineering and Applied Chemistry, Aston University, Birmingham, UK
| | - Aisling Mann
- Biomaterials Research Unit, Chemical Engineering and Applied Chemistry, Aston University, Birmingham, UK
| | - Fiona Lydon
- Biomaterials Research Unit, Chemical Engineering and Applied Chemistry, Aston University, Birmingham, UK
| | - Frank Molock
- Biomaterials Research Unit, Chemical Engineering and Applied Chemistry, Aston University, Birmingham, UK
| | - Siân A Layton
- Biomaterials Research Unit, Chemical Engineering and Applied Chemistry, Aston University, Birmingham, UK
| | | | - Jonathan R Howse
- Department of Chemical and Biological Engineering, University of Sheffield, Sheffield, UK
| | - Paul D Topham
- Aston Institute of Materials Research (AIMR), Chemical Engineering and Applied Chemistry, Aston University, Birmingham, UK
| | - Brian J Tighe
- Biomaterials Research Unit, Chemical Engineering and Applied Chemistry, Aston University, Birmingham, UK
| |
Collapse
|
25
|
Fast versus gradual adaptation of soft daily disposable contact lenses in neophyte wearers. Cont Lens Anterior Eye 2020; 43:268-273. [DOI: 10.1016/j.clae.2019.08.011] [Citation(s) in RCA: 9] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/12/2019] [Revised: 08/08/2019] [Accepted: 08/31/2019] [Indexed: 11/19/2022]
|
26
|
Efron N, Brennan NA, Chalmers RL, Jones L, Lau C, Morgan PB, Nichols JJ, Szczotka-Flynn LB, Willcox MD. Thirty years of 'quiet eye' with etafilcon A contact lenses. Cont Lens Anterior Eye 2020; 43:285-297. [PMID: 32278644 DOI: 10.1016/j.clae.2020.03.015] [Citation(s) in RCA: 19] [Impact Index Per Article: 4.8] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/17/2019] [Revised: 03/27/2020] [Accepted: 03/28/2020] [Indexed: 11/17/2022]
Abstract
Frequent replacement contact lenses made from the etafilcon A hydrogel lens material were introduced onto the market over 30 years ago, and etafilcon A remains the most widely used hydrogel lens material today. Although the prescribing of silicone hydrogel lenses is increasing, millions of lens wearers globally have been wearing hydrogel lenses for many years and exhibit a physiologically-stable 'quiet eye', with a low profile of adverse events. Hydrogel lenses are demonstrated to maintain a low inflammatory response and infection risk profile during daily wear, which in the case of etafilcon A, may be related to its low modulus, and the naturally-protective, anti-microbial, non-denatured lysozyme absorbed into the lens from the tear fluid. Although improved corneal physiology from decreased hypoxia with silicone hydrogel lenses is well accepted, equivalent levels of corneal oxygenation are maintained during daily wear of low to medium powered hydrogel lenses, which do not impede the daily corneal de-swelling process, and do not induce clinically significant changes in ocular health. Therefore, hydrogel lenses remain an important alternative for daily wear in modern contact lens practice.
Collapse
Affiliation(s)
- Nathan Efron
- Institute of Health and Biomedical Innovation, School of Optometry and Vision Science, Queensland University of Technology, Australia.
| | | | | | - Lyndon Jones
- Centre for Ocular Research & Education (CORE), School of Optometry & Vision Science, University of Waterloo, Waterloo, ON, Canada
| | - Charis Lau
- Johnson & Johnson Vision, Inc, Jacksonville, FL, USA
| | - Philip B Morgan
- Eurolens Research, Division of Pharmacy and Optometry, The University of Manchester, UK
| | - Jason J Nichols
- The University of Alabama at Birmingham, School of Optometry, Birmingham, AL, USA
| | - Loretta B Szczotka-Flynn
- University Hospitals Eye Institute, University Hospitals Cleveland Medical Center, Department of Ophthalmology & Visual Sciences, Case Western Reserve University, Cleveland, OH, USA
| | - Mark D Willcox
- School of Optometry and Vision Science, University of New South Wales, Sydney, Australia
| |
Collapse
|
27
|
The relationship between tear film MMP-9 and meibomian gland changes during soft contact lens wear. Cont Lens Anterior Eye 2020; 43:154-158. [DOI: 10.1016/j.clae.2019.07.007] [Citation(s) in RCA: 10] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/24/2019] [Revised: 06/17/2019] [Accepted: 07/16/2019] [Indexed: 01/08/2023]
|
28
|
|
29
|
Absorption and Extraction of Inflammatory Mediators From Contact Lens Materials. Eye Contact Lens 2019; 45:340-345. [DOI: 10.1097/icl.0000000000000576] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/26/2022]
|
30
|
Moezzi AM, Varikooty J, Luensmann D, Schulze MM, Ng A, Karkkainen T, Xu J, Jones L. The short-term physiological impact of switching reusable silicone hydrogel wearers into a hydrogel daily disposable multifocal. Clin Ophthalmol 2019; 13:1193-1202. [PMID: 31371916 PMCID: PMC6636608 DOI: 10.2147/opth.s208905] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/16/2019] [Accepted: 05/14/2019] [Indexed: 01/14/2023] Open
Abstract
Purpose: To evaluate ocular physiological responses to etafilcon A multifocal (etMF) daily disposable (DD) lenses after 4 weeks of wear, when switching from habitual silicone hydrogel (SiHy) daily wear. Method: A single-arm, open-label, bilateral dispensing study was conducted in 39 habitual spherical SiHy wearers (14 hyperopes; 25 myopes). Clinical visits occurred with habitual SiHy (control) at baseline and after 4 weeks of etMF DD open-eye lens wear at exit. Objective limbal/bulbar hyperemia using the Oculus K5M (0–4) and subjective grading of lid wiper epitheliopathy (LWE) (0–4) were tested for non-inferiority (NI), using a margin of 1 grade. Corneal thickness along a 10 mm cord was measured using the Visante OCT and tested for NI using a 30 μm margin. Corneal staining area was graded (0–100%). Results: The least-square mean differences (LSMD) and 95% confidence interval (95% CI) between etMF DD and habitual SiHy in central and peripheral corneal thickness (μm) were 3.64 (−2.0, 9.29) and 3.0 (−7.72, 13.72) in hyperopic, and 3.56 (−0.66, 7.78) and 6.40 (−1.62, 14.42) in myopic subjects. The LSMD (95% CI) for bulbar and limbal hyperemia were −0.08 (−0.19, 0.02) and −0.01 (−0.12, 0.09) in hyperopes, and 0.04 (−0.03, 0.12) and 0.04 (−0.04, 0.11) in myopes. The LSMD (95% CI) for LWE were 0.11 (−0.39, 0.60) and 0.30 (−0.07, 0.67) for hyperopes and myopes, respectively. Conclusions: No clinically significant differences in a variety of physiological responses were found when habitual reusable SiHy daily wear subjects were refitted into hydrogel etMF, when the subjects were followed for 4 weeks.
Collapse
Affiliation(s)
- Amir M Moezzi
- Centre for Ocular Research & Education (CORE, formerly Centre for Contact Lens Research), School of Optometry and Vision Science, University of Waterloo, Waterloo, Ontario, Canada
| | - Jalaiah Varikooty
- Centre for Ocular Research & Education (CORE, formerly Centre for Contact Lens Research), School of Optometry and Vision Science, University of Waterloo, Waterloo, Ontario, Canada
| | - Doerte Luensmann
- Centre for Ocular Research & Education (CORE, formerly Centre for Contact Lens Research), School of Optometry and Vision Science, University of Waterloo, Waterloo, Ontario, Canada
| | - Marc-Matthias Schulze
- Centre for Ocular Research & Education (CORE, formerly Centre for Contact Lens Research), School of Optometry and Vision Science, University of Waterloo, Waterloo, Ontario, Canada
| | - Alison Ng
- Centre for Ocular Research & Education (CORE, formerly Centre for Contact Lens Research), School of Optometry and Vision Science, University of Waterloo, Waterloo, Ontario, Canada
| | - Thomas Karkkainen
- Research and Development, Johnson & Johnson Vision, Jacksonville, FL, USA
| | - Jing Xu
- Research and Development, Johnson & Johnson Vision, Jacksonville, FL, USA
| | - Lyndon Jones
- Centre for Ocular Research & Education (CORE, formerly Centre for Contact Lens Research), School of Optometry and Vision Science, University of Waterloo, Waterloo, Ontario, Canada
| |
Collapse
|
31
|
Rashad R, Weed MC, Quinn N, Chen VM. Extended Wear Bandage Contact Lenses Decrease Pain and Preserve Vision in Patients with Epidermolysis Bullosa: Case Series and Review of Literature. Ocul Immunol Inflamm 2019; 28:379-383. [DOI: 10.1080/09273948.2019.1587472] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/27/2022]
Affiliation(s)
- Ramy Rashad
- Tufts University School of Medicine, Boston, MA, USA
| | | | - Nicole Quinn
- New England College of Optometry, Boston, MA, USA
| | - Vicki M. Chen
- Tufts Medical Center, Boston, MA, USA
- New England Eye Center, Boston, MA, USA
| |
Collapse
|
32
|
Mann A, Sáez‐Martinez V, Lydon F, Tighe B. Investigating the permeation properties of contact lenses and its influence on tear electrolyte composition. J Biomed Mater Res B Appl Biomater 2018; 107:1997-2005. [DOI: 10.1002/jbm.b.34291] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/26/2018] [Revised: 10/30/2018] [Accepted: 11/10/2018] [Indexed: 01/09/2023]
Affiliation(s)
- Aisling Mann
- Biomaterials Research Unit, School of Engineering and Applied ScienceAston University Birmingham B4 7ET UK
| | - Virginia Sáez‐Martinez
- Biomaterials Research Unit, School of Engineering and Applied ScienceAston University Birmingham B4 7ET UK
| | - Fiona Lydon
- Biomaterials Research Unit, School of Engineering and Applied ScienceAston University Birmingham B4 7ET UK
| | - Brian Tighe
- Biomaterials Research Unit, School of Engineering and Applied ScienceAston University Birmingham B4 7ET UK
| |
Collapse
|
33
|
Abstract
The purpose of this article is to provide a review of existing literature describing complications with contemporary contact lenses and their management. It is envisioned that this will serve as a useful summary of noninfectious and infectious complications associated with contact lens wear.
Collapse
|
34
|
Comparative Analysis of Adverse Events From a Series of Proof-of-Principle Extended Wear Studies. Eye Contact Lens 2018; 45:88-92. [PMID: 30080693 DOI: 10.1097/icl.0000000000000546] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/26/2022]
Abstract
AIM A series of proof-of-principle extended wear (EW) contact lens studies were conducted to assess what effect different interventions had on adverse events (AEs). Comparative analysis of AEs across studies was conducted to determine whether some interventions were more effective at reducing inflammatory AEs. METHOD Multiple logistic regression analysis of AEs from 30-day EW studies each with a different intervention including (1) nightly replacement (NR) of lenses, (2) morning replacement (MR) of lenses, (3) instillation of prophylactic antibiotic drops (AB) each morning/evening, (4) daily lens cleaning (LC) each morning. All studies conducted at the same site using same lens type (lotrafilcon A) and EW schedule. RESULTS Comparison of the different interventions to the individual control groups showed no difference in significant corneal infiltrative event (CIE) or mechanical events. Replacing lenses nightly, during an EW schedule, had the highest incidence of significant CIEs (4.9% [NR] vs. 2.5% [MR] vs. 1.8% [AB] vs. 0% [LC]); however, adjusted logistic regression analysis of the combined control data compared with the individual interventions showed no difference in significant CIEs (P=0.086) or mechanical AEs (P=0.140). CONCLUSIONS Replacing lenses each night seemed to be inferior compared with the other interventions of replacing lenses each morning, daily lens cleaning, and daily antibiotic drop instillation during EW. The results of the collective studies and additional analysis suggest that overnight wear of contact lenses seems to create an adverse environment that remains, despite the various interventions intended to improve this adverse environment.
Collapse
|
35
|
Food and Drug Administration, American Academy of Ophthalmology, American Academy of Optometry, American Association for Pediatric Ophthalmology and Strabismus, American Optometric Association, American Society of Cataract and Refractive Surgery, and Contact Lens Association of Ophthalmologists Co-Sponsored Workshop: Controlling the Progression of Myopia: Contact Lenses and Future Medical Devices. Eye Contact Lens 2018; 44:205-211. [DOI: 10.1097/icl.0000000000000511] [Citation(s) in RCA: 17] [Impact Index Per Article: 2.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/25/2022]
|
36
|
Daily Wear Contact Lenses Manufactured in Etafilcon A Are Noninferior to Two Silicone Hydrogel Lens Types With Respect to Hypoxic Stress. Eye Contact Lens 2018; 44:190-199. [DOI: 10.1097/icl.0000000000000335] [Citation(s) in RCA: 11] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/26/2022]
|
37
|
López-De La Rosa A, Arroyo-Del Arroyo C, Cañadas P, López-Miguel A, Calonge M, Enríquez-De-Salamanca A, González-García MJ. Are Contact Lens Discomfort or Soft Contact Lens Material Properties Associated with Alterations in the Corneal Sub-Basal Nerve Plexus? Curr Eye Res 2017; 43:487-492. [DOI: 10.1080/02713683.2017.1420804] [Citation(s) in RCA: 12] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/01/2023]
Affiliation(s)
- Alberto López-De La Rosa
- Instituto Universitario de Oftalmobiología Aplicada (IOBA), University of Valladolid, Valladolid, Spain
- Departamento de Física Teórica, Atómica y Óptica, University of Valladolid, Valladolid, Spain
| | - Cristina Arroyo-Del Arroyo
- Instituto Universitario de Oftalmobiología Aplicada (IOBA), University of Valladolid, Valladolid, Spain
- Departamento de Física Teórica, Atómica y Óptica, University of Valladolid, Valladolid, Spain
| | - Pilar Cañadas
- Instituto Universitario de Oftalmobiología Aplicada (IOBA), University of Valladolid, Valladolid, Spain
- Departamento de Física Teórica, Atómica y Óptica, University of Valladolid, Valladolid, Spain
| | - Alberto López-Miguel
- Instituto Universitario de Oftalmobiología Aplicada (IOBA), University of Valladolid, Valladolid, Spain
| | - Margarita Calonge
- Instituto Universitario de Oftalmobiología Aplicada (IOBA), University of Valladolid, Valladolid, Spain
- Networking Research Center on Bioengineering, Biomaterials and Nanomedicine (CIBER-BBN), Valladolid, Spain
| | - Amalia Enríquez-De-Salamanca
- Instituto Universitario de Oftalmobiología Aplicada (IOBA), University of Valladolid, Valladolid, Spain
- Networking Research Center on Bioengineering, Biomaterials and Nanomedicine (CIBER-BBN), Valladolid, Spain
| | - María J González-García
- Instituto Universitario de Oftalmobiología Aplicada (IOBA), University of Valladolid, Valladolid, Spain
- Departamento de Física Teórica, Atómica y Óptica, University of Valladolid, Valladolid, Spain
- Networking Research Center on Bioengineering, Biomaterials and Nanomedicine (CIBER-BBN), Valladolid, Spain
| |
Collapse
|
38
|
The quality of systematic reviews about interventions for refractive error can be improved: a review of systematic reviews. BMC Ophthalmol 2017; 17:164. [PMID: 28870179 PMCID: PMC5584039 DOI: 10.1186/s12886-017-0561-9] [Citation(s) in RCA: 23] [Impact Index Per Article: 3.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/05/2017] [Accepted: 08/30/2017] [Indexed: 01/08/2023] Open
Abstract
BACKGROUND Systematic reviews should inform American Academy of Ophthalmology (AAO) Preferred Practice Pattern® (PPP) guidelines. The quality of systematic reviews related to the forthcoming Preferred Practice Pattern® guideline (PPP) Refractive Errors & Refractive Surgery is unknown. We sought to identify reliable systematic reviews to assist the AAO Refractive Errors & Refractive Surgery PPP. METHODS Systematic reviews were eligible if they evaluated the effectiveness or safety of interventions included in the 2012 PPP Refractive Errors & Refractive Surgery. To identify potentially eligible systematic reviews, we searched the Cochrane Eyes and Vision United States Satellite database of systematic reviews. Two authors identified eligible reviews and abstracted information about the characteristics and quality of the reviews independently using the Systematic Review Data Repository. We classified systematic reviews as "reliable" when they (1) defined criteria for the selection of studies, (2) conducted comprehensive literature searches for eligible studies, (3) assessed the methodological quality (risk of bias) of the included studies, (4) used appropriate methods for meta-analyses (which we assessed only when meta-analyses were reported), (5) presented conclusions that were supported by the evidence provided in the review. RESULTS We identified 124 systematic reviews related to refractive error; 39 met our eligibility criteria, of which we classified 11 to be reliable. Systematic reviews classified as unreliable did not define the criteria for selecting studies (5; 13%), did not assess methodological rigor (10; 26%), did not conduct comprehensive searches (17; 44%), or used inappropriate quantitative methods (3; 8%). The 11 reliable reviews were published between 2002 and 2016. They included 0 to 23 studies (median = 9) and analyzed 0 to 4696 participants (median = 666). Seven reliable reviews (64%) assessed surgical interventions. CONCLUSIONS Most systematic reviews of interventions for refractive error are low methodological quality. Following widely accepted guidance, such as Cochrane or Institute of Medicine standards for conducting systematic reviews, would contribute to improved patient care and inform future research.
Collapse
|
39
|
Steele KR, Szczotka-Flynn L. Epidemiology of contact lens-induced infiltrates: an updated review. Clin Exp Optom 2017; 100:473-481. [PMID: 28868803 DOI: 10.1111/cxo.12598] [Citation(s) in RCA: 34] [Impact Index Per Article: 4.9] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/01/2017] [Revised: 07/10/2017] [Accepted: 07/11/2017] [Indexed: 11/29/2022] Open
Abstract
Corneal infiltrative events (CIEs) are well established as a risk associated with soft contact lens wear. The incidence of symptomatic CIEs during extended soft lens wear ranges from 2.5 to six per cent; when asymptomatic CIEs are included, the incidence can be as high as 20-25 per cent. In daily soft lens wear, the annual incidence of symptomatic CIEs is about three per cent. There are various accepted methods of categorising CIEs, and a scoring system based on clinical signs and symptoms is a good approach to grade severity. Lens-related risk factors include extended wear, silicone hydrogel material, the use of multipurpose solutions, bacterial bioburden and reusable lenses. Recent studies report that daily disposable lenses reduce the risk of CIEs.
Collapse
Affiliation(s)
- Kelsy R Steele
- The Ohio State University College of Optometry, Columbus, Ohio, USA
| | - Loretta Szczotka-Flynn
- University Hospitals Eye Institute, University Hospitals Cleveland Medical Center, Cleveland, Ohio, USA.,Department of Ophthalmology and Visual Sciences, Case Western Reserve University, Cleveland, Ohio, USA
| |
Collapse
|
40
|
Abstract
Purpose There is increasing interest in fitting children with soft contact lenses. This review collates data from a range of studies to estimate the incidence of complications, specifically corneal infiltrative events and microbial keratitis, in patients under the age of 18 years. Methods Peer-review papers were identified using PubMed and the Web of Science. A broad range of studies are summarized including large-scale epidemiological studies of contact lens–related complications, hospital-based case series, long- and short-term prospective studies, and multicenter retrospective studies. Results Nine prospective studies representing 1800 patient years of wear in 7- to 19-year-olds include safety outcomes. In three large prospective studies representing between 159 and 723 patient years of soft contact lens wear in patients 8 to 14 years, the incidence of corneal infiltrative events is up to 136 per 10,000 years. Data from a large retrospective study show similar rates of corneal infiltrative events: 97 per 10,000 years in 8- to 12-year-olds (based on 411 patient years of wear) and 335 per 10,000 years in 13- to 17-year-olds (based on 1372 patient years of wear). None of the prospective studies report any cases of microbial keratitis. Five clinical studies where safety data are not reported constitute a further 493 patient years. One retrospective study found no cases of microbial keratitis occurred in 8- to 12-year-olds (411 patient years) and an incidence of 15 per 10,000 patient years in 13- to 17-year-olds (1372 patient years)—no higher than the incidence of microbial keratitis in adults wearing soft contact lenses on an overnight basis. Conclusions The overall picture is that the incidence of corneal infiltrative events in children is no higher than in adults, and in the youngest age range of 8 to 11 years, it may be markedly lower.
Collapse
|
41
|
Kocluk Y, Cetinkaya S, Sukgen EA, Günay M, Mete A. Comparing the effects of two different contact lenses on corneal re-epithelialization after corneal collagen cross-linking. Pak J Med Sci 2017; 33:680-685. [PMID: 28811794 PMCID: PMC5510126 DOI: 10.12669/pjms.333.12241] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/15/2022] Open
Abstract
OBJECTIVE To investigate whether keratoconus (KC) patients who applied the corneal collagen cross-linking (CXL) and two different contact lens (CL) showed any differences in complaints and findings following the CXL. METHODS This prospective, comparative, double-blind clinical study involved 60 eyes of 60 patients (38 female and 22 male). At the end of the CXL procedure, CL (Balafilcon A) was inserted in 29 patients (Group-1) while CL with different material content (Hioxifilcon A) designed for therapeutic/bandage purposes were inserted in 31 patients (Group-2). RESULTS On the 1st and 3th day after the CXL, there were no statistically significant differences between the groups in terms of the postoperative symptoms. On the 3th day after the CXL, all cases of both two groups were found to complete the corneal re-epithelialization. There was more PE ratio in the patients who had allergic conjunctivitis. CONCLUSIONS With the use of Balafilcon A and Hioxifilcon A lens materials, KC patients who underwent the CXL were found to have similar symptoms and clinical findings after the CXL. However, epithelial staining and PE were observed more in KC cases accompanied by allergic conjunctivitis.
Collapse
Affiliation(s)
- Yusuf Kocluk
- Yusuf Kocluk, MD. Adana Numune Training and Research Hospital, Ophthalmology Clinic, Adana, Turkey
| | - Savas Cetinkaya
- Savas Cetinkaya, MD. Adana Numune Training and Research Hospital, Ophthalmology Clinic, Adana, Turkey
| | - Emine Alyamac Sukgen
- Emine Alyamac Sukgen, MD Adana Numune Training and Research Hospital, Ophthalmology Clinic, Adana, Turkey
| | - Murat Günay
- Murat Günay, MD. Ophthalmology Clinic, Zeynep Kamil Gynecology and Pediatrics Education and Research Hospital, Istanbul, Turkey
| | - Alper Mete
- Alper Mete, MD. Gaziantep University, School of Medicine, Department of Ophthalmology, Gaziantep, Turkey
| |
Collapse
|
42
|
Hinojosa JA, Patel NB, Zhu M, Robertson DM. Antimicrobial Efficacy of Contact Lens Care Solutions Against Neutrophil-Enhanced Bacterial Biofilms. Transl Vis Sci Technol 2017; 6:11. [PMID: 28473944 PMCID: PMC5412968 DOI: 10.1167/tvst.6.2.11] [Citation(s) in RCA: 10] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/23/2016] [Accepted: 02/21/2017] [Indexed: 12/28/2022] Open
Abstract
Purpose Neutrophil-derived extracellular debris has been shown to accelerate bacterial biofilm formation on hydrogel and silicone hydrogel contact lens surfaces compared to lenses inoculated with bacteria alone. The purpose of this study was to evaluate the disinfection efficacy of four standard commercial contact lens cleaning regimens against neutrophil-enhanced bacterial biofilms formed on silicone hydrogel contact lenses. Methods Four reference strains were used: Pseudomonas aeruginosa,Serratia marcescens,Stenotrophomonas maltophilia, and Staphylococcus aureus. Human neutrophils were isolated from peripheral blood by venipuncture. Unworn Lotrafilcon B lenses were incubated overnight in each respective strain with stimulated neutrophils. Contact lenses were then cleaned using one of four contact lens care solutions according to manufacturer instructions. Bacterial viability was assessed by colony counts and confocal microscopy. Volume of residual debris on lens surfaces after cleaning was quantified using IMARIS software. Results All four solutions tested showed effective antimicrobial activity against each bacterial strain; however, substantial amounts of nonviable bacteria and cellular debris remained on the lens surface despite concomitant digital cleaning. Conclusions Necrotic cellular debris that accumulates under the posterior lens surface during wear of an inoculated contact lens is not fully removed during routine cleaning and disinfection. Translational Relevance The accumulation of residual cellular debris on the contact lens surface may contribute to new colonization of the lens and represents a significant risk factor for a contact lens–related adverse event. Additional studies are needed to correlate these findings with risk for corneal infiltrative and/or infectious events in a standard animal model.
Collapse
Affiliation(s)
- Jorge A Hinojosa
- Department of Ophthalmology, University of Texas Southwestern Medical Center, Dallas, TX, USA
| | - Naiya B Patel
- Department of Ophthalmology, University of Texas Southwestern Medical Center, Dallas, TX, USA
| | - Meifang Zhu
- Department of Ophthalmology, University of Texas Southwestern Medical Center, Dallas, TX, USA
| | - Danielle M Robertson
- Department of Ophthalmology, University of Texas Southwestern Medical Center, Dallas, TX, USA
| |
Collapse
|
43
|
Qin G, Zhu Z, Li S, McDermott AM, Cai C. Development of ciprofloxacin-loaded contact lenses using fluorous chemistry. Biomaterials 2017; 124:55-64. [PMID: 28188995 DOI: 10.1016/j.biomaterials.2017.01.046] [Citation(s) in RCA: 18] [Impact Index Per Article: 2.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/30/2016] [Revised: 01/17/2017] [Accepted: 01/29/2017] [Indexed: 02/06/2023]
Abstract
In this work, we developed a simple method to load drugs into commercially available contact lenses utilizing fluorous chemistry. We demonstrated this method using model compounds including fluorous-tagged fluorescein and antibiotic ciprofloxacin. We showed that fluorous interactions facilitated the loading of model molecules into fluorocarbon-containing contact lenses, and that the release profiles exhibited sustained release. Contact lenses loaded with fluorous-tagged ciprofloxacin exhibited antimicrobial activity against Pseudomonas aeruginosa in vitro, while no cytotoxicity towards human corneal epithelial cells was observed. To mimic the tear turnover, we designed a porcine eye infection model under flow conditions. Significantly, the modified lenses also exhibited antimicrobial efficacy against Pseudomonas aeruginosa in the ex vivo infection model. Overall, utilizing fluorous chemistry, we can construct a drug delivery system that exhibits high drug loading capacity, sustained drug release, and robust biological activity.
Collapse
Affiliation(s)
- Guoting Qin
- College of Optometry, University of Houston, Houston, TX, 77204, USA.
| | - Zhiling Zhu
- Department of Chemistry, University of Houston, Houston, TX, 77204, USA
| | - Siheng Li
- Department of Chemistry, University of Houston, Houston, TX, 77204, USA
| | | | - Chengzhi Cai
- Department of Chemistry, University of Houston, Houston, TX, 77204, USA.
| |
Collapse
|
44
|
Stapleton F, Keay L, Szczotka-Flynn L, Carnt N, Lindsley K, Schein O. Silicone hydrogel contact lenses versus hydrogel daily wear contact lenses for the correction of simple refractive error. Hippokratia 2016. [DOI: 10.1002/14651858.cd009320.pub2] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/06/2022]
Affiliation(s)
- Fiona Stapleton
- University of New South Wales; School of Optometry and Vision Science; Level 3 North Wing, Rupert Myers Building Sydney Australia 2052
| | - Lisa Keay
- The University of Sydney; The George Institute for Global Health; Level 24, Maritime Trade Towers 207 Kent Street Sydney NSW Australia 2000
| | - Loretta Szczotka-Flynn
- University Hospitals Case Medical Center, Case Western Reserve University; Department of Ophthalmology; Cleveland Ohio USA
| | - Nicole Carnt
- University of New South Wales; School of Optometry and Vision Science and Institute for Eye Research; Level 3 North Wing, Rupert Myers Building Sydney Australia 2052
| | - Kristina Lindsley
- Johns Hopkins Bloomberg School of Public Health; Department of Epidemiology; 615 North Wolfe Street, Mail Room E6132 Baltimore Maryland USA 21205
| | - Oliver Schein
- Johns Hopkins University School of Medicine; Wilmer Eye Institute; 600 N. Wolfe Street, Wilmer 116 Baltimore Maryland USA 21287-9019
| |
Collapse
|
45
|
Zimmerman AB, Emch AJ, Geldis J, Nixon GJ, Mitchell GL. Contact Lens Corneal Inflammatory Events in a University Population. Optom Vis Sci 2016; 93:42-9. [DOI: 10.1097/opx.0000000000000746] [Citation(s) in RCA: 11] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/25/2022] Open
|
46
|
Effect of Daily Contact Lens Cleaning on Ocular Adverse Events during Extended Wear. Optom Vis Sci 2015; 92:157-66. [DOI: 10.1097/opx.0000000000000479] [Citation(s) in RCA: 10] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/26/2022] Open
|
47
|
Muntz A, Subbaraman LN, Sorbara L, Jones L. Tear exchange and contact lenses: a review. JOURNAL OF OPTOMETRY 2015; 8:2-11. [PMID: 25575892 PMCID: PMC4314619 DOI: 10.1016/j.optom.2014.12.001] [Citation(s) in RCA: 47] [Impact Index Per Article: 5.2] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 08/04/2014] [Revised: 11/07/2014] [Accepted: 11/26/2014] [Indexed: 05/29/2023]
Abstract
Tear exchange beneath a contact lens facilitates ongoing fluid replenishment between the ocular surface and the lens. This exchange is considerably lower during the wear of soft lenses compared with rigid lenses. As a result, the accumulation of tear film debris and metabolic by-products between the cornea and a soft contact lens increases, potentially leading to complications. Lens design innovations have been proposed, but no substantial improvement in soft lens tear exchange has been reported. Researchers have determined post-lens tear exchange using several methods, notably fluorophotometry. However, due to technological limitations, little remains known about tear hydrodynamics around the lens and, to-date, true tear exchange with contact lenses has not been shown. Further knowledge regarding tear exchange could be vital in aiding better contact lens design, with the prospect of alleviating certain adverse ocular responses. This article reviews the literature to-date on the significance, implications and measurement of tear exchange with contact lenses.
Collapse
Affiliation(s)
- Alex Muntz
- Centre for Contact Lens Research, School of Optometry and Vision Science, University of Waterloo, Ontario, Canada.
| | - Lakshman N Subbaraman
- Centre for Contact Lens Research, School of Optometry and Vision Science, University of Waterloo, Ontario, Canada
| | - Luigina Sorbara
- Centre for Contact Lens Research, School of Optometry and Vision Science, University of Waterloo, Ontario, Canada
| | - Lyndon Jones
- Centre for Contact Lens Research, School of Optometry and Vision Science, University of Waterloo, Ontario, Canada
| |
Collapse
|
48
|
The significance of oxygen during contact lens wear. Cont Lens Anterior Eye 2014; 37:394-404. [DOI: 10.1016/j.clae.2014.07.012] [Citation(s) in RCA: 25] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/26/2014] [Revised: 07/19/2014] [Accepted: 07/22/2014] [Indexed: 11/30/2022]
|
49
|
|
50
|
|