1
|
English K. Echo contrast medium: How the use of contrast echocardiography (ultrasound contrast agents) can improve patient care. World J Methodol 2025; 15. [DOI: 10.5662/wjm.v15.i3.100490] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 08/18/2024] [Revised: 12/14/2024] [Accepted: 12/20/2024] [Indexed: 03/06/2025] Open
Abstract
Conventional echocardiography can sometimes pose a challenge to diagnosis due to sub-optimal images. Ultrasound contrast agents (UCAs) have been shown to drastically enhance imaging quality, particularly depicting the left ventricular endocardial borders. Their use during echocardiography has become a valuable tool in non-invasive diagnostics. UCAs provide higher-quality images that may ultimately reduce the length of hospital stays and improve patient care. The higher cost associated with UCAs in many situations has been an impediment to frequent use. However, when used as an initial diagnostic test, UCA during rest echocardiogram is more cost-effective than the traditional diagnostic approach, which frequently includes multiple tests and imaging studies to make an accurate diagnosis. They can be easily performed across multiple patient settings and provide optimal images that allow clinicians to make sound medical decisions. This consequently allows for better diagnostic accuracies and improvement in patient care.
Collapse
Affiliation(s)
- Kevan English
- Department of Internal Medicine, University of Nebraska Medical Center College of Medicine, Omaha, NE 68198, United States
| |
Collapse
|
2
|
Davis LM, Martinez-Correa S, Freeman CW, Adams C, Sultan LR, Le DQ, Lemessa N, Darge K, Hwang M. Ultrasound innovations in abdominal radiology: techniques and clinical applications in pediatric imaging. Abdom Radiol (NY) 2025; 50:1744-1762. [PMID: 39406993 PMCID: PMC11947074 DOI: 10.1007/s00261-024-04616-x] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/02/2024] [Revised: 09/17/2024] [Accepted: 09/24/2024] [Indexed: 01/03/2025]
Abstract
Contrast-enhanced ultrasound, microvascular imaging, elastography, and fat quantification have varying degrees of utility, with some applications in the pediatric setting mirroring that in adults and having unique uses when applied to children in others. This review will present novel ultrasound technologies and the clinical context in which they are applied to the pediatric abdomen. New ultrasound technologies have a broad range of applications in clinical practice and represent a powerful diagnostic tool with the potential to replace other imaging modalities, such as magnetic resonance imaging and computed tomography, in specific cases.
Collapse
Affiliation(s)
| | | | | | | | - Laith R Sultan
- Children's Hospital of Philadelphia, Philadelphia, PA, USA
| | - David Q Le
- Children's Hospital of Philadelphia, Philadelphia, PA, USA
| | - Natae Lemessa
- Children's Hospital of Philadelphia, Philadelphia, PA, USA
| | - Kassa Darge
- Children's Hospital of Philadelphia, Philadelphia, PA, USA
- University of Pennsylvania, Philadelphia, PA, USA
| | - Misun Hwang
- Children's Hospital of Philadelphia, Philadelphia, PA, USA.
- University of Pennsylvania, Philadelphia, PA, USA.
| |
Collapse
|
3
|
Nguyen DN, Huyghens L, Nguyen TM, Diltoer M, Jonckheer J, Cools W, Segers L, Schiettecatte J, Vincent JL. Alterations in Regional Brain Microcirculation in Patients with Sepsis: A Prospective Study Using Contrast-Enhanced Brain Ultrasound. Neurocrit Care 2025; 42:428-439. [PMID: 39313698 DOI: 10.1007/s12028-024-02117-9] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/15/2023] [Accepted: 08/23/2024] [Indexed: 09/25/2024]
Abstract
BACKGROUND Alterations in regional brain microcirculation have not been well studied in patients with sepsis. Regional brain microcirculation can be studied using contrast-enhanced brain ultrasound (CEUS) with microbubble administration. METHODS CEUS was used to assess alterations in regional brain microcirculation on 3 consecutive days in 58 patients with sepsis and within 24 h of intensive care unit admission in 10 aged-matched nonseptic postoperative patients. Time-intensity perfusion curve variables (time-to-peak and peak intensity) were measured in different regions of interest of the brain parenchyma. The mean arterial pressure, cardiac index (using transthoracic echocardiography), global cerebral blood flow (using echo-color Doppler of the carotid and vertebral arteries), mean flow velocities of the middle cerebral arteries, and brain autoregulation (using transcranial echo-color Doppler) were measured simultaneously. The presence of structural brain injury in patients with sepsis was confirmed on computed tomography imaging, and encephalopathy, including coma and delirium, was evaluated using the Glasgow Coma Scale and the Confusion Assessment Method in the Intensive Care Unit. RESULTS Of the 58 patients with sepsis, 42 (72%) developed acute encephalopathy and 11 (19%) had some form of structural brain injury. Brain autoregulation was impaired in 23 (40%) of the patients with sepsis. Brain microcirculation alterations were observed in the left lentiform nucleus and left white matter of the temporoparietal region of the middle cerebral artery in the sepsis nonsurvivors but not in the survivors or postoperative patients. The alterations were characterized by prolonged time-to-peak (p < 0.01) and decreased peak intensity (p < 0.01) on the time-intensity perfusion curve. Prolonged time-to-peak but not decreased peak intensity was independently associated with worse outcome (p = 0.03) but not with the development of encephalopathy (p = 0.77). CONCLUSIONS Alterations in regional brain microcirculation are present in critically ill patients with sepsis and are associated with poor outcome. Trial registration Registered retrospectively on December 19, 2019.
Collapse
Affiliation(s)
- Duc Nam Nguyen
- Department of Critical Care Medicine, Universitair Ziekenhuis Brussel, Vrije Universiteit Brussel, Laarbeeklaan 101, 1090, Brussels, Belgium.
| | - Luc Huyghens
- Brain Resuscitation in Neurosciences Research Group, Faculty of Medicine, Vrije Universiteit Brussel, Brussels, Belgium
| | - Truc Mai Nguyen
- Department of Geriatrics, University Hospital Vaudois, Lausanne, Switzerland
| | - Marc Diltoer
- Department of Critical Care Medicine, Universitair Ziekenhuis Brussel, Vrije Universiteit Brussel, Laarbeeklaan 101, 1090, Brussels, Belgium
| | - Joop Jonckheer
- Department of Critical Care Medicine, Universitair Ziekenhuis Brussel, Vrije Universiteit Brussel, Laarbeeklaan 101, 1090, Brussels, Belgium
| | - Wilfried Cools
- Department of Biostatistics, Vrije Universiteit Brussel, Brussels, Belgium
| | - Lotte Segers
- Department of Critical Care Medicine, Universitair Ziekenhuis Brussel, Vrije Universiteit Brussel, Laarbeeklaan 101, 1090, Brussels, Belgium
| | - Johan Schiettecatte
- Department of Immunochemistry, Universitair Ziekenhuis Brussel, Vrije Universiteit Brussel, Brussels, Belgium
| | - Jean-Louis Vincent
- Department of Intensive Care, Erasme Hospital, Université Libre de Bruxelles, Brussels, Belgium
| |
Collapse
|
4
|
Rusu M, Jahanandish H, Vesal S, Li CX, Bhattacharya I, Venkataraman R, Zhou SR, Kornberg Z, Sommer ER, Khandwala YS, Hockman L, Zhou Z, Choi MH, Ghanouni P, Fan RE, Sonn GA. ProCUSNet: Prostate Cancer Detection on B-mode Transrectal Ultrasound Using Artificial Intelligence for Targeting During Prostate Biopsies. Eur Urol Oncol 2025; 8:477-485. [PMID: 39880746 PMCID: PMC11930619 DOI: 10.1016/j.euo.2024.12.012] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/07/2024] [Revised: 12/06/2024] [Accepted: 12/27/2024] [Indexed: 01/31/2025]
Abstract
BACKGROUND AND OBJECTIVE To assess whether conventional brightness-mode (B-mode) transrectal ultrasound images of the prostate reveal clinically significant cancers with the help of artificial intelligence methods. METHODS This study included 2986 men who underwent biopsies at two institutions. We trained the PROstate Cancer detection on B-mode transrectal UltraSound images NETwork (ProCUSNet) to determine whether ultrasound can reliably detect cancer. Specifically, ProCUSNet is based on the well-established nnUNet frameworks, and seeks to detect and outline clinically significant cancer on three-dimensional (3D) examinations reconstructed from 2D screen captures. We compared ProCUSNet against (1) reference labels (n = 515 patients), (2) eight readers that interpreted B-mode ultrasound (n = 20-80 patients), and (3) radiologists interpreting magnetic resonance imaging (MRI) for clinical care (n = 110 radical prostatectomy patients). KEY FINDINGS AND LIMITATIONS ProCUSNet found 82% clinically significant cancer cases with a lesion boundary error of up to 2.67 mm and detected 42% more lesions than ultrasound readers (sensitivity: 0.86 vs 0.44, p < 0.05, Wilcoxon test, Bonferroni correction). Furthermore, ProCUSNet has similar performance to radiologists interpreting MRI when accounting for registration errors (sensitivity: 0.79 vs 0.78, p > 0.05, Wilcoxon test, Bonferroni correction), while having the same targeting utility as a supplement to systematic biopsies. CONCLUSIONS AND CLINICAL IMPLICATIONS ProCUSNet can localize clinically significant cancer on screen capture B-mode ultrasound, a task that is particularly challenging for clinicians reading these examinations. As a supplement to systematic biopsies, ProCUSNet appears comparable with MRI, suggesting its utility for targeting suspicious lesions during the biopsy and possibly for screening using ultrasound alone, in the absence of MRI.
Collapse
Affiliation(s)
- Mirabela Rusu
- Department of Radiology Stanford University Stanford CA USA; Department of Urology Stanford University Stanford CA USA; Stanford University, Department of Biomedical Data Science, 300 Pasteur, Stanford, CA USA.
| | - Hassan Jahanandish
- Department of Radiology Stanford University Stanford CA USA; Department of Urology Stanford University Stanford CA USA
| | - Sulaiman Vesal
- Department of Radiology Stanford University Stanford CA USA; Department of Urology Stanford University Stanford CA USA
| | - Cynthia Xinran Li
- Institute of Computational and Mathematical Engineering Stanford University Stanford CA USA
| | | | | | - Steve Ran Zhou
- Department of Urology Stanford University Stanford CA USA
| | | | | | | | - Luke Hockman
- Department of Urology Stanford University Stanford CA USA
| | - Zhien Zhou
- Peking Union Medical College Hospital Beijing China
| | - Moon Hyung Choi
- Department of Radiology, College of Medicine, The Catholic University of Korea Seoul Korea
| | | | - Richard E Fan
- Department of Urology Stanford University Stanford CA USA
| | - Geoffrey A Sonn
- Department of Radiology Stanford University Stanford CA USA; Department of Urology Stanford University Stanford CA USA
| |
Collapse
|
5
|
Lee AA, Antil N, El Kaffas A, Park WG. Assessing the Feasibility of Handheld Point-of-Care Ultrasound for Pancreas Visualization: A Pilot Study. Pancreas 2025; 54:e382-e383. [PMID: 39626170 DOI: 10.1097/mpa.0000000000002435] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 04/24/2025]
Affiliation(s)
- Alice A Lee
- Division of Gastroenterology and Hepatology, and
| | - Neha Antil
- Department of Radiology, Stanford University, Stanford, CA
| | | | | |
Collapse
|
6
|
Aires LPN, Gasser B, Del'Aguila-Silva P, Gonçalves JD, Uscategui RAR, Spada S, De Felice D, Russo M, Lima BB, Gimenes LU, Feliciano MAR. Multiparametric ultrasound (MPUS) evaluation of the testes of normozoospermic dogs - a pilot study. Sci Rep 2025; 15:7121. [PMID: 40016296 PMCID: PMC11868414 DOI: 10.1038/s41598-025-91087-9] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/17/2024] [Accepted: 02/18/2025] [Indexed: 03/01/2025] Open
Abstract
Ultrasound is an important tool in small animal andrology for assessing the integrity of the testes. This study explores ultrasound's role in assessing the canine testes and understanding the correlation of sonographic parameters to sperm quality. It investigates B-mode and Doppler ultrasound techniques alongside advanced methods like Shear-wave Elastography (SWE) and Contrast-enhanced ultrasound (CEUS). The aim was to standardize a multiparametric ultrasound (MPUS) evaluation protocol using these techniques in normozoospermic dogs. Eight healthy male dogs were assessed. B-mode assessed testicular morphology, while Doppler evaluated testicular artery waveform morphology and velocimetric parameters. SWE measured testicular stiffness, and CEUS assessed testicular perfusion. Seminal parameters were also analyzed. Results revealed normal B-mode sonographic findings and some correlations between Doppler parameters and sperm quality. SWE demonstrated consistent testicular stiffness regardless of the depth of evaluation, with correlations of the stiffness of the head of the epididymis to the ejaculate volume. CEUS identified blood flow differences between testes and some perfusion parameters correlated with sperm features. This comprehensive ultrasound assessment provides valuable insights into canine reproductive health, providing basis for further studies on dogs with abnormal sperm quality and with different fertility statuses.
Collapse
Affiliation(s)
- Luiz Paulo Nogueira Aires
- Department of Veterinary Clinic and Surgery, School of Agricultural and Veterinarian Sciences, São Paulo State University "Júlio de Mesquita Filho" (FCAV/UNESP), Jaboticabal, São Paulo, Brazil.
| | - Beatriz Gasser
- Instituto de Ciências Agrárias, Universidade Federal dos Vales do Jequitinhonha e Mucuri (UFVJM), Unaí, Minas Gerais, Brazil
| | - Priscila Del'Aguila-Silva
- Department of Pathology, Reproduction and One Health, School of Agricultural and Veterinarian Sciences, São Paulo State University "Júlio de Mesquita Filho" (FCAV/UNESP), Jaboticabal, São Paulo, Brazil
| | - Joedson Dantas Gonçalves
- Department of Pathology, Reproduction and One Health, School of Agricultural and Veterinarian Sciences, São Paulo State University "Júlio de Mesquita Filho" (FCAV/UNESP), Jaboticabal, São Paulo, Brazil
| | | | - Stefano Spada
- Department of Veterinary Medicine and Animal Productions, University of Naples "Federico II", Naples, Italy
- Clinic of Reproductive Medicine, Vetsuisse Faculty, University of Zurich, Zurich, Switzerland
| | - Daniela De Felice
- Department of Veterinary Medicine and Animal Productions, University of Naples "Federico II", Naples, Italy
| | - Marco Russo
- Department of Veterinary Medicine and Animal Productions, University of Naples "Federico II", Naples, Italy
| | - Bruna Bressianini Lima
- Department of Veterinary Clinic and Surgery, School of Agricultural and Veterinarian Sciences, São Paulo State University "Júlio de Mesquita Filho" (FCAV/UNESP), Jaboticabal, São Paulo, Brazil
| | - Lindsay Unno Gimenes
- Department of Pathology, Reproduction and One Health, School of Agricultural and Veterinarian Sciences, São Paulo State University "Júlio de Mesquita Filho" (FCAV/UNESP), Jaboticabal, São Paulo, Brazil
| | - Marcus Antônio Rossi Feliciano
- Department of Veterinary Clinic and Surgery, School of Agricultural and Veterinarian Sciences, São Paulo State University "Júlio de Mesquita Filho" (FCAV/UNESP), Jaboticabal, São Paulo, Brazil
- Laboratory of Veterinary Imaginology, Faculty of Animal Science and Food Engineering (FZEA), São Paulo University (USP), Pirassununga, São Paulo, Brazil
| |
Collapse
|
7
|
Arthur L, Voulgaridou V, Papageorgiou G, Lu W, McDougall SR, Sboros V. Super-resolution ultrasound imaging of ischaemia flow: An in silico study. J Theor Biol 2025; 599:112018. [PMID: 39647660 DOI: 10.1016/j.jtbi.2024.112018] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/20/2024] [Revised: 10/29/2024] [Accepted: 12/01/2024] [Indexed: 12/10/2024]
Abstract
Super-resolution ultrasound (SRU) is a new ultrasound imaging mode that promises to facilitate the detection of microvascular disease by providing new vascular bio-markers that are directly linked to microvascular pathophysiology, thereby augmenting current knowledge and potentially enabling new treatment. Such a capability can be developed through thorough understanding as articulated by means of mathematical models. In this study, a 2D numerical flow model is adopted for generating flow adaptation in response to ischaemia, in order to determine the ability of SRU to register the resulting flow perturbations. The flow model results demonstrate that variations in flow behaviour in response to locally induced ischaemia can be significant throughout the entire vascular bed. Measured velocities have variations that are dependent on the location of ischaemia, with median values ranging between 2-7 mms-1. Moreover, the distinction between healthy and ischaemic networks are recorded accurately in the SRU results showing excellent agreement between SRU maps and the model. Up to 7-fold spatial resolution improvement to conventional contrast ultrasound was achieved in microbubble localisation while the detection precision and recall was consistently above 98%. The microbubble tracking precision was of a similar accuracy, whereas the recall was reduced (77%) under varying ischaemic impacted flow. Further, regions with velocities up to 30 mms-1 are in excellent agreement with SRU maps, while at regions that include a proportion of higher velocities, the median velocity values are within 1.28%-3.32% of the ground-truth. In conclusion, SRU is a highly promising methodology for the direct measurement of microvascular flow dynamics and may provide a valuable tool for the understanding and subsequent modelling of behaviour in the vascular bed.
Collapse
Affiliation(s)
- Lachlan Arthur
- School of Engineering & Physical Sciences, Heriot-Watt University, Edinburgh, EH14 4AS, Scotland, United Kingdom.
| | - Vasiliki Voulgaridou
- Translational Healthcare Technologies Team, Centre for Inflammation Research, University of Edinburgh, Edinburgh, EH16 4TJ, Scotland, United Kingdom.
| | - Georgios Papageorgiou
- School of Engineering & Physical Sciences, Heriot-Watt University, Edinburgh, EH14 4AS, Scotland, United Kingdom.
| | - Weiping Lu
- School of Engineering & Physical Sciences, Heriot-Watt University, Edinburgh, EH14 4AS, Scotland, United Kingdom.
| | - Steven R McDougall
- School of Energy, Geoscience, Infrastructure and Society, Heriot-Watt University, Edinburgh, EH14 4AS, Scotland, United Kingdom.
| | - Vassilis Sboros
- School of Engineering & Physical Sciences, Heriot-Watt University, Edinburgh, EH14 4AS, Scotland, United Kingdom.
| |
Collapse
|
8
|
Zeng Z, Liu Z, Xia H, Zhu J, Liu Z, Zhang L. Contrast-enhanced ultrasound for assessing pre-operative lymphatic vessel function and post-operative anastomotic patency in lymphatic-venous anastomosis: a retrospective observational study. Acad Radiol 2025:S1076-6332(25)00102-3. [PMID: 39984337 DOI: 10.1016/j.acra.2025.02.001] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/04/2024] [Revised: 02/01/2025] [Accepted: 02/01/2025] [Indexed: 02/23/2025]
Abstract
RATIONALE AND OBJECTIVES Lymphedema represents a significant global health challenge, severely impacting patient quality of life. Lymphatic-venous Anastomosis (LVA) is commonly employed as an effective intervention for patients with lymphedema. However, existing imaging tests for localizing lymphatic vessels exhibit various limitations; Consequently, there is a need for a more effective comprehensive method that can be employed for both preoperative localization of lymphatic vessels and postoperative patency assessment. METHODS Under local anesthesia, Contrast-enhanced Ultrasound (CEUS) was utilized to assess lymphatic vessel function and localize it prior to LVA in eight patients with refractory lymphedema following breast cancer surgery. High-frequency Ultrasound was employed for the localization of superficial vein. One-week post-surgery, CEUS was performed on all patients to assess the patency of anastomoses, and to evaluate surgical outcomes based on the number of visible patent anastomoses, anastomotic patency rates, and other indicators. RESULTS Prior to surgery, 68 pooled lymphatic vessels were visualized in eight patients, six of them exhibited tortuous and dilated. Lymphatic vessels with uniform internal diameter and intact continuity were selected for preoperative localization of LVA. Postoperatively, the anastomoses were clearly visualized and demonstrated a relatively high patency rate (26/41,63.2%). The patent anastomoses underwent "spider-like" changes. The internal diameters of the collecting lymphatic vessels were narrower post-operation compared to pre-operation measurements. Furthermore, six months after surgery, the internal diameters of the collecting lymphatic vessels of the affected limbs had decreased, with the maximum reduction reaching 11 cm. CONCLUSION The cases in this study underscore the utility of CEUS in both preoperative assessment and localization of LVA and postoperative evaluation of anastomotic patency. This could represent a new technique that might supersede traditional methods such as Indocyanine Green (ICG) and become a routine assessment tool after LVA.
Collapse
Affiliation(s)
- Zishan Zeng
- Department of B-Ultrasound, the 1st affiliated hospital, Jiangxi Medical College, Nanchang University, 330000 China
| | - Zijie Liu
- Department of B-Ultrasound, the 1st affiliated hospital, Jiangxi Medical College, Nanchang University, 330000 China
| | - Houyu Xia
- Department of B-Ultrasound, the 1st affiliated hospital, Jiangxi Medical College, Nanchang University, 330000 China
| | - Jia Zhu
- Department of General Surgery, the 1st affiliated hospital, Jiangxi Medical College, Nanchang University, 330000 China
| | - Zhengren Liu
- Department of General Surgery, the 1st affiliated hospital, Jiangxi Medical College, Nanchang University, 330000 China
| | - Lili Zhang
- Department of B-Ultrasound, the 1st affiliated hospital, Jiangxi Medical College, Nanchang University, 330000 China.
| |
Collapse
|
9
|
Arthur LJMB, Voulgaridou V, Butler MB, Papageorgiou G, Lu W, McDougall SR, Sboros V. Comparison of contrast-enhanced ultrasound imaging (CEUS) and super-resolution ultrasound (SRU) for the quantification of ischaemia flow redistribution: a theoretical study. Phys Med Biol 2024; 69:235006. [PMID: 39536710 PMCID: PMC11583374 DOI: 10.1088/1361-6560/ad9231] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/06/2024] [Accepted: 11/13/2024] [Indexed: 11/16/2024]
Abstract
The study of microcirculation can reveal important information related to pathology. Focusing on alterations that are represented by an obstruction of blood flow in microcirculatory regions may provide an insight into vascular biomarkers. The current in silico study assesses the capability of contrast enhanced ultrasound (CEUS) and super-resolution ultrasound imaging (SRU) flow-quantification to study occlusive actions in a microvascular bed, particularly the ability to characterise known and model induced flow behaviours. The aim is to investigate theoretical limits with the use of CEUS and SRU in order to propose realistic biomarker targets relevant for clinical diagnosis. Results from CEUS flow parameters display limitations congruent with prior investigations. Conventional resolution limits lead to signals dominated by large vessels, making discrimination of microvasculature specific signals difficult. Additionally, some occlusions lead to weakened parametric correlation against flow rate in the remainder of the network. Loss of correlation is dependent on the degree to which flow is redistributed, with comparatively minor redistribution correlating in accordance with ground truth measurements for change in mean transit time,dMTT(CEUS,R = 0.85; GT,R = 0.82) and change in peak intensity,dIp(CEUS,R = 0.87; GT,R = 0.96). Major redistributions, however, result in a loss of correlation, demonstrating that the effectiveness of time-intensity curve parameters is influenced by the site of occlusion. Conversely, results from SRU processing provides accurate depiction of the anatomy and dynamics present in the vascular bed, that extends to individual microvessels. Correspondence between model vessel structure displayed in SRU maps with the ground truth was>91%for cases of minor and major flow redistributions. In conclusion, SRU appears to be a highly promising technology in the quantification of subtle flow phenomena due ischaemia induced vascular flow redistribution.
Collapse
Affiliation(s)
- Lachlan J M B Arthur
- School of Engineering & Physical Sciences, Heriot-Watt University, Edinburgh EH14 4AS, United Kingdom
| | - Vasiliki Voulgaridou
- Translational Healthcare Technologies Team, Centre for Inflammation Research, University of Edinburgh, Edinburgh EH16 4TJ, United Kingdom
| | - Mairead B Butler
- School of Engineering & Physical Sciences, Heriot-Watt University, Edinburgh EH14 4AS, United Kingdom
| | - Georgios Papageorgiou
- School of Engineering & Physical Sciences, Heriot-Watt University, Edinburgh EH14 4AS, United Kingdom
| | - Weiping Lu
- School of Engineering & Physical Sciences, Heriot-Watt University, Edinburgh EH14 4AS, United Kingdom
| | - Steven R McDougall
- School of Energy, Geoscience, Infrastructure and Society, Heriot-Watt University, Edinburgh EH14 4AS, United Kingdom
| | - Vassilis Sboros
- School of Engineering & Physical Sciences, Heriot-Watt University, Edinburgh EH14 4AS, United Kingdom
| |
Collapse
|
10
|
Ogorevc N, Slak P, Nikšić S, Novljan G, Fister P, Plut D. Contrast-Enhanced Ultrasound (CEUS) and Ultra-Microangiography (UMA) in Critically Ill Children with Acute Kidney Injury. CHILDREN (BASEL, SWITZERLAND) 2024; 11:1205. [PMID: 39457170 PMCID: PMC11506883 DOI: 10.3390/children11101205] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 09/03/2024] [Revised: 09/28/2024] [Accepted: 09/29/2024] [Indexed: 10/28/2024]
Abstract
Acute kidney injury (AKI) is an acute condition of impaired kidney function with decreased glomerular filtration rate, which results in dysregulation in volume, electrolyte, and acid-base equilibrium. AKI can be a life-threatening condition and can also lead to chronic kidney disease. It is important to diagnose AKI early in the course of the disease or to predict its development, as this can influence therapeutic decisions, outcome, and, consequently, the prognosis. In clinical practice, an elevated serum creatinine concentration remains the most common laboratory indicator for diagnosing AKI. However, due to the delay in its rise, creatinine levels are often insensitive and inaccurate for early diagnosis. Novel biomarkers of kidney tubular injury and the renal angina index have shown promise in predicting AKI earlier and more accurately. Contrast-enhanced ultrasonography (CEUS) and ultra-microangiography (UMA) are radiological methods that can quantify renal microperfusion and may be able to predict the development of AKI. They have not yet been used for quantifying renal perfusion in children with risk factors for developing AKI. Further research is needed to compare these sonographic techniques with the renal angina index and emerging kidney injury biomarkers for predicting acute kidney injury (AKI) in both children and adults.
Collapse
Affiliation(s)
- Nace Ogorevc
- Clinical Radiology Institute, University Medical Centre Ljubljana, 1000 Ljubljana, Slovenia; (P.S.); (D.P.)
- Faculty of Medicine, University of Ljubljana, 1000 Ljubljana, Slovenia
| | - Peter Slak
- Clinical Radiology Institute, University Medical Centre Ljubljana, 1000 Ljubljana, Slovenia; (P.S.); (D.P.)
- Faculty of Medicine, University of Ljubljana, 1000 Ljubljana, Slovenia
| | - Stevan Nikšić
- Clinical Radiology Institute, University Medical Centre Ljubljana, 1000 Ljubljana, Slovenia; (P.S.); (D.P.)
- Faculty of Medicine, University of Ljubljana, 1000 Ljubljana, Slovenia
| | - Gregor Novljan
- Faculty of Medicine, University of Ljubljana, 1000 Ljubljana, Slovenia
- Pediatric Nephrology Department, Children’s Hospital, University Medical Centre Ljubljana, 1000 Ljubljana, Slovenia
| | - Petja Fister
- Faculty of Medicine, University of Ljubljana, 1000 Ljubljana, Slovenia
- Department of Pediatric Intensive Care, Children’s Hospital, University Medical Centre Ljubljana, 1000 Ljubljana, Slovenia
| | - Domen Plut
- Clinical Radiology Institute, University Medical Centre Ljubljana, 1000 Ljubljana, Slovenia; (P.S.); (D.P.)
- Faculty of Medicine, University of Ljubljana, 1000 Ljubljana, Slovenia
| |
Collapse
|
11
|
Li Y, Tang J, Mao D, Dragomir MP, Li Y, Sun K, Lv Z, Liu X, Meng X, Lu K. MRI-CEUS fusion-guided lymphatic mapping as a preoperative strategy for lymphedema patients undergoing lymphaticovenous anastomosis surgery. J Vasc Surg Venous Lymphat Disord 2024; 12:101907. [PMID: 38759752 PMCID: PMC11523411 DOI: 10.1016/j.jvsv.2024.101907] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/13/2023] [Revised: 04/06/2024] [Accepted: 05/03/2024] [Indexed: 05/19/2024]
Abstract
OBJECTIVE Contrast-enhanced ultrasound (CEUS) is useful in mapping lymphatic vessels in upper limb lymphedema; this study was aimed to evaluate its efficiency in lower limb lymphedema and investigate whether magnetic resonance lymphangiography (MRL) enhance the efficiency of CEUS. METHODS This retrospective study enrolled 48 patients with lymphedema undergoing lymphaticovenous anastomosis (LVA) surgery who received MRL and/or CEUS in addition to conventional indocyanine green (ICG) lymphangiography. The number of anastomotic sites and the duration per site (DPS) for LVA surgery were described and compared. RESULTS Among the 48 patients subjected to analysis, it was observed that 12 (25%), 20 (41.67%), and 16 (33.33%) of them received ICG, ICG+CEUS, and ICG+CEUS+MRL, respectively. The ICG+CEUS group demonstrated a significant increase in the number of LVAs (median, 5; range, 4-7), compared with the ICG group (median, 2; range, 1-4) (P < .001). Moreover, the ICG+CEUS+MRL group exhibited a higher number of LVAs (median, 8; range, 7-8.25) compared with both the ICG+CEUS and ICG groups (P < .001). For lower limb lymphedema, the ICG+CEUS+MRL group displayed an elevated number of LVAs (median, 8; interquartile range, 7-9) (P = .003), in contrast to the ICG group (median, 3; interquartile range, 1.75-4.25). Furthermore, the DPS in the ICG+CEUS+MRL group (median, 50.56; interquartile range, 48.13-59.29) (P = .005) exhibited a remarkable decrease when compared with the ICG group (median, 131.25; interquartile range, 86.75-198.13]). CONCLUSIONS MRL-CEUS fusion demonstrates superior performance in the identification of lymphatic vessels for lymphedema.
Collapse
Affiliation(s)
- Yongfeng Li
- Division of General Surgery, Cancer Center, Department of Breast Surgery, Zhejiang Provincial People's Hospital (Affiliated People's Hospital), Hangzhou Medical College, Hangzhou, China
| | - Jinglan Tang
- Cancer Center, Department of Ultrasound Medicine, Zhejiang Provincial People's Hospital (Affiliated People's Hospital), Hangzhou Medical College, Hangzhou, China
| | - Dewang Mao
- Cancer Center, Department of Radiology, Zhejiang Provincial People's Hospital (Affiliated People's Hospital), Hangzhou Medical College, Hangzhou, China
| | - Mihnea P Dragomir
- Institute of Pathology, Charité - Universitätsmedizin Berlin, Corporate Member of Freie Universität Berlin, Humboldt-Universität zu, Berlin, Germany; German Cancer Consortium (DKTK), Partner Site Berlin, and German Cancer Research Center (DKFZ), Heidelberg, Germany; Berlin Institute of Health, Berlin, Germany
| | - Ying Li
- Division of General Surgery, Cancer Center, Department of Breast Surgery, Zhejiang Provincial People's Hospital (Affiliated People's Hospital), Hangzhou Medical College, Hangzhou, China
| | - Kewang Sun
- Division of General Surgery, Cancer Center, Department of Breast Surgery, Zhejiang Provincial People's Hospital (Affiliated People's Hospital), Hangzhou Medical College, Hangzhou, China
| | - Zhenye Lv
- Division of General Surgery, Cancer Center, Department of Breast Surgery, Zhejiang Provincial People's Hospital (Affiliated People's Hospital), Hangzhou Medical College, Hangzhou, China
| | - Xiaozhen Liu
- Division of General Surgery, Cancer Center, Department of Breast Surgery, Zhejiang Provincial People's Hospital (Affiliated People's Hospital), Hangzhou Medical College, Hangzhou, China
| | - Xuli Meng
- Division of General Surgery, Cancer Center, Department of Breast Surgery, Zhejiang Provincial People's Hospital (Affiliated People's Hospital), Hangzhou Medical College, Hangzhou, China
| | - Kefeng Lu
- Cancer Center, Department of Ultrasound Medicine, Zhejiang Provincial People's Hospital (Affiliated People's Hospital), Hangzhou Medical College, Hangzhou, China.
| |
Collapse
|
12
|
Lerendegui M, Riemer K, Papageorgiou G, Wang B, Arthur L, Chavignon A, Zhang T, Couture O, Huang P, Ashikuzzaman M, Dencks S, Dunsby C, Helfield B, Jensen JA, Lisson T, Lowerison MR, Rivaz H, Samir AE, Schmitz G, Schoen S, van Sloun R, Song P, Stevens T, Yan J, Sboros V, Tang MX. ULTRA-SR Challenge: Assessment of Ultrasound Localization and TRacking Algorithms for Super-Resolution Imaging. IEEE TRANSACTIONS ON MEDICAL IMAGING 2024; 43:2970-2987. [PMID: 38607705 DOI: 10.1109/tmi.2024.3388048] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 04/14/2024]
Abstract
With the widespread interest and uptake of super-resolution ultrasound (SRUS) through localization and tracking of microbubbles, also known as ultrasound localization microscopy (ULM), many localization and tracking algorithms have been developed. ULM can image many centimeters into tissue in-vivo and track microvascular flow non-invasively with sub-diffraction resolution. In a significant community effort, we organized a challenge, Ultrasound Localization and TRacking Algorithms for Super-Resolution (ULTRA-SR). The aims of this paper are threefold: to describe the challenge organization, data generation, and winning algorithms; to present the metrics and methods for evaluating challenge entrants; and to report results and findings of the evaluation. Realistic ultrasound datasets containing microvascular flow for different clinical ultrasound frequencies were simulated, using vascular flow physics, acoustic field simulation and nonlinear bubble dynamics simulation. Based on these datasets, 38 submissions from 24 research groups were evaluated against ground truth using an evaluation framework with six metrics, three for localization and three for tracking. In-vivo mouse brain and human lymph node data were also provided, and performance assessed by an expert panel. Winning algorithms are described and discussed. The publicly available data with ground truth and the defined metrics for both localization and tracking present a valuable resource for researchers to benchmark algorithms and software, identify optimized methods/software for their data, and provide insight into the current limits of the field. In conclusion, Ultra-SR challenge has provided benchmarking data and tools as well as direct comparison and insights for a number of the state-of-the art localization and tracking algorithms.
Collapse
|
13
|
Chen JS, Goubran M, Kim G, Kim MJ, Willmann JK, Zeineh M, Hristov D, Kaffas AE. Motion correction of 3D dynamic contrast-enhanced ultrasound imaging without anatomical B-Mode images: Pilot evaluation in eight patients. Med Phys 2024; 51:4827-4837. [PMID: 38377383 PMCID: PMC11913309 DOI: 10.1002/mp.16995] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/22/2023] [Revised: 12/05/2023] [Accepted: 01/05/2024] [Indexed: 02/22/2024] Open
Abstract
BACKGROUND Dynamic contrast-enhanced ultrasound (DCE-US) is highly susceptible to motion artifacts arising from patient movement, respiration, and operator handling and experience. Motion artifacts can be especially problematic in the context of perfusion quantification. In conventional 2D DCE-US, motion correction (MC) algorithms take advantage of accompanying side-by-side anatomical B-Mode images that contain time-stable features. However, current commercial models of 3D DCE-US do not provide side-by-side B-Mode images, which makes MC challenging. PURPOSE This work introduces a novel MC algorithm for 3D DCE-US and assesses its efficacy when handling clinical data sets. METHODS In brief, the algorithm uses a pyramidal approach whereby short temporal windows consisting of three consecutive frames are created to perform local registrations, which are then registered to a master reference derived from a weighted average of all frames. We applied the algorithm to imaging studies from eight patients with metastatic lesions in the liver and assessed improvements in original versus motion corrected 3D DCE-US cine using: (i) frame-to-frame volumetric overlap of segmented lesions, (ii) normalized correlation coefficient (NCC) between frames (similarity analysis), and (iii) sum of squared errors (SSE), root-mean-squared error (RMSE), and r-squared (R2) quality-of-fit from fitted time-intensity curves (TIC) extracted from a segmented lesion. RESULTS We noted improvements in frame-to-frame lesion overlap across all patients, from 68% ± 13% without correction to 83% ± 3% with MC (p = 0.023). Frame-to-frame similarity as assessed by NCC also improved on two different sets of time points from 0.694 ± 0.057 (original cine) to 0.862 ± 0.049 (corresponding MC cine) and 0.723 ± 0.066 to 0.886 ± 0.036 (p ≤ 0.001 for both). TIC analysis displayed a significant decrease in RMSE (p = 0.018) and a significant increase in R2 goodness-of-fit (p = 0.029) for the patient cohort. CONCLUSIONS Overall, results suggest decreases in 3D DCE-US motion after applying the proposed algorithm.
Collapse
Affiliation(s)
- Jia-Shu Chen
- Department of Neuroscience, Brown University, Providence, Rhode Island, USA
- The Warren Alpert Medical School, Brown University, Providence, Rhode Island, USA
| | - Maged Goubran
- Sunnybrook Health Sciences Center, Toronto, Ontario, Canada
- Department of Radiology, Stanford University, Stanford, California, USA
| | - Gaeun Kim
- Department of Radiology, Stanford University, Stanford, California, USA
| | - Matthew J. Kim
- Department of Radiation Oncology – Radiation Physics, Stanford School of Medicine, Stanford University, Stanford, California, USA
| | - Jürgen K. Willmann
- Department of Radiology, Molecular Imaging Program, Stanford School of Medicine, Stanford University, Stanford, California, USA
| | - Michael Zeineh
- Department of Radiology, Stanford University, Stanford, California, USA
| | - Dimitre Hristov
- Department of Radiation Oncology – Radiation Physics, Stanford School of Medicine, Stanford University, Stanford, California, USA
| | - Ahmed El Kaffas
- Department of Radiology, Molecular Imaging Program, Stanford School of Medicine, Stanford University, Stanford, California, USA
| |
Collapse
|
14
|
Hillaert A, Sanmiguel Serpa LC, Bogaert S, Broeckx BJG, Hesta M, Vandermeulen E, Germonpré J, Stock E, Pullens P, Vanderperren K. Assessment of pharmacologically induced changes in canine kidney function by multiparametric magnetic resonance imaging and contrast enhanced ultrasound. Front Vet Sci 2024; 11:1406343. [PMID: 38966564 PMCID: PMC11223176 DOI: 10.3389/fvets.2024.1406343] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/24/2024] [Accepted: 06/11/2024] [Indexed: 07/06/2024] Open
Abstract
IntroductionDynamic contrast-enhanced (DCE) MRI and arterial spin labeling (ASL) MRI enable non-invasive measurement of renal blood flow (RBF), whereas blood oxygenation level-dependent (BOLD) MRI enables non-invasive measurement of the apparent relaxation rate (R2*), an indicator of oxygenation. This study was conducted to evaluate the potential role of these MRI modalities in assessing RBF and oxygenation in dogs. The correlation between contrast-enhanced ultrasound (CEUS) and the MRI modalities was examined and also the ability of the MRI modalities to detect pharmacologically induced changes.MethodsRBF, using CEUS, ASL- and DCE-MRI, as well as renal oxygenation, using BOLD-MRI of eight adult beagles were assessed at two time-points, 2–3 weeks apart. During each time point, the anesthetized dogs received either a control (0.9% sodium chloride) or a dopamine treatment. For each time point, measurements were carried out over 2 days. An MRI scan at 3 T was performed on day one, followed by CEUS on day two.ResultsUsing the model-free model with caudal placement of the arterial input function (AIF) region of interest (ROI) in the aorta, the DCE results showed a significant correlation with ASL measured RBF and detected significant changes in blood flow during dopamine infusion. Additionally, R2* negatively correlated with ASL measured RBF at the cortex and medulla, as well as with medullary wash-in rate (WiR) and peak intensity (PI). ASL measured RBF, in its turn, showed a positive correlation with cortical WiR, PI, area under the curve (AUC) and fall time (FT), and with medullary WiR and PI, but a negative correlation with medullary rise time (RT). During dopamine infusion, BOLD-MRI observed a significant decrease in R2* at the medulla and entire kidney, while ASL-MRI demonstrated a significant increase in RBF at the cortex, medulla and the entire kidney.ConclusionASL- and BOLD-MRI can measure pharmacologically induced changes in renal blood flow and renal oxygenation in dogs and might allow detection of changes that cannot be observed with CEUS. However, further research is needed to confirm the potential of ASL- and BOLD-MRI in dogs and to clarify which analysis method is most suitable for DCE-MRI in dogs.
Collapse
Affiliation(s)
- Amber Hillaert
- Department of Morphology, Imaging, Orthopedics, Rehabilitation and Nutrition, Faculty of Veterinary Medicine, Ghent University, Merelbeke, Belgium
| | - Luis Carlos Sanmiguel Serpa
- Department of Medical Imaging, Ghent University Hospital, Ghent, Belgium
- Ghent Institute for Functional and Metabolic Imaging, Ghent University, Ghent, Belgium
- Department of Diagnostic Sciences, Faculty of Medicine and Health Sciences, Ghent University, Ghent, Belgium
| | - Stephanie Bogaert
- Department of Medical Imaging, Ghent University Hospital, Ghent, Belgium
- Ghent Institute for Functional and Metabolic Imaging, Ghent University, Ghent, Belgium
| | - Bart J. G. Broeckx
- Department of Veterinary and Biosciences, Faculty of Veterinary Medicine, Ghent University, Merelbeke, Belgium
| | - Myriam Hesta
- Department of Morphology, Imaging, Orthopedics, Rehabilitation and Nutrition, Faculty of Veterinary Medicine, Ghent University, Merelbeke, Belgium
| | - Eva Vandermeulen
- Department of Morphology, Imaging, Orthopedics, Rehabilitation and Nutrition, Faculty of Veterinary Medicine, Ghent University, Merelbeke, Belgium
| | - Jolien Germonpré
- Department of Morphology, Imaging, Orthopedics, Rehabilitation and Nutrition, Faculty of Veterinary Medicine, Ghent University, Merelbeke, Belgium
| | - Emmelie Stock
- Department of Morphology, Imaging, Orthopedics, Rehabilitation and Nutrition, Faculty of Veterinary Medicine, Ghent University, Merelbeke, Belgium
| | - Pim Pullens
- Department of Medical Imaging, Ghent University Hospital, Ghent, Belgium
- Ghent Institute for Functional and Metabolic Imaging, Ghent University, Ghent, Belgium
- Institute of Biomedical Engineering and Technology, Faculty of Engineering and Architecture, Ghent University, Ghent, Belgium
| | - Katrien Vanderperren
- Department of Morphology, Imaging, Orthopedics, Rehabilitation and Nutrition, Faculty of Veterinary Medicine, Ghent University, Merelbeke, Belgium
| |
Collapse
|
15
|
Tufano A, Rosati D, Moriconi M, Santarelli V, Canale V, Salciccia S, Sciarra A, Franco G, Cantisani V, Di Pierro GB. Diagnostic Accuracy of Contrast-Enhanced Ultrasound (CEUS) in the Detection of Muscle-Invasive Bladder Cancer: A Systematic Review and Diagnostic Meta-Analysis. Curr Oncol 2024; 31:818-827. [PMID: 38392054 PMCID: PMC10888477 DOI: 10.3390/curroncol31020060] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/02/2024] [Revised: 01/17/2024] [Accepted: 01/30/2024] [Indexed: 02/24/2024] Open
Abstract
BACKGROUND Contrast-enhanced ultrasound (CEUS) is a diagnostic tool that is gaining popularity for its ability to improve overall diagnostic accuracy in bladder cancer (BC) staging. Our aim is to determine the cumulative diagnostic performance of CEUS in predicting preoperative muscle invasiveness using a comprehensive systematic review and pooled meta-analysis. METHODS A systematic review until October 2023 was performed according to the Preferred Reporting Items for Systematic Reviews and Meta-Analyses (PRISMA) statement. Patients with BC suspicion were offered CEUS before the transurethral resection of the bladder tumor (TURBT). The diagnostic performance of CEUS was evaluated based on non-muscle-invasive bladder cancer (NMIBC) vs. muscle-invasive bladder cancer (MIBC) confirmed at the final histopathological examination after TURBT. The outcomes were determined through pooled sensitivity, specificity, pooled positive likelihood ratio (PLR+), negative likelihood ratio (PLR-), and area under the summary receiver operating characteristic (SROC) along with their respective 95% confidence intervals (CI). RESULTS Overall, five studies were included. In these studies, a total of 362 patients underwent CEUS prior to TURBT. The pooled sensitivity and specificity were 0.88 (95% CI: 0.81-0.93) and 0.88 (95% CI: 0.82-0.92), respectively. SROC curve depicted a diagnostic accuracy of 0.94 (95% CI: 0.81-0.98). The pooled PLR+ and PLR- were 7.3 (95% CI: 4.8-11.2) and 0.14 (95% CI: 0.08-0.23), respectively. CONCLUSIONS Our meta-analysis indicates that CEUS is highly accurate in the diagnosis and staging for BC. Beyond its accuracy, CEUS offers the advantage of being a cost-effective, safe, and versatile imaging tool.
Collapse
Affiliation(s)
- Antonio Tufano
- Department of Maternal-Infant and Urological Sciences, “Sapienza” Rome University, Policlinico Umberto I Hospital, 00185 Rome, Italy
| | - Davide Rosati
- Department of Maternal-Infant and Urological Sciences, “Sapienza” Rome University, Policlinico Umberto I Hospital, 00185 Rome, Italy
| | - Martina Moriconi
- Department of Maternal-Infant and Urological Sciences, “Sapienza” Rome University, Policlinico Umberto I Hospital, 00185 Rome, Italy
| | - Valerio Santarelli
- Department of Maternal-Infant and Urological Sciences, “Sapienza” Rome University, Policlinico Umberto I Hospital, 00185 Rome, Italy
| | - Vittorio Canale
- Department of Maternal-Infant and Urological Sciences, “Sapienza” Rome University, Policlinico Umberto I Hospital, 00185 Rome, Italy
| | - Stefano Salciccia
- Department of Maternal-Infant and Urological Sciences, “Sapienza” Rome University, Policlinico Umberto I Hospital, 00185 Rome, Italy
| | - Alessandro Sciarra
- Department of Maternal-Infant and Urological Sciences, “Sapienza” Rome University, Policlinico Umberto I Hospital, 00185 Rome, Italy
| | - Giorgio Franco
- Department of Maternal-Infant and Urological Sciences, “Sapienza” Rome University, Policlinico Umberto I Hospital, 00185 Rome, Italy
| | - Vito Cantisani
- Department of Radiology, Oncology and Pathology, University La Sapienza of Rome, 00185 Rome, Italy
| | - Giovanni Battista Di Pierro
- Department of Maternal-Infant and Urological Sciences, “Sapienza” Rome University, Policlinico Umberto I Hospital, 00185 Rome, Italy
| |
Collapse
|
16
|
Routkevitch D, Soulé Z, Kats N, Baca E, Hersh AM, Kempski-Leadingham KM, Menta AK, Bhimreddy M, Jiang K, Davidar AD, Smit C, Theodore N, Thakor NV, Manbachi A. Non-contrast ultrasound image analysis for spatial and temporal distribution of blood flow after spinal cord injury. Sci Rep 2024; 14:714. [PMID: 38184676 PMCID: PMC10771432 DOI: 10.1038/s41598-024-51281-7] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/17/2023] [Accepted: 01/03/2024] [Indexed: 01/08/2024] Open
Abstract
Ultrasound technology can provide high-resolution imaging of blood flow following spinal cord injury (SCI). Blood flow imaging may improve critical care management of SCI, yet its duration is limited clinically by the amount of contrast agent injection required for high-resolution, continuous monitoring. In this study, we aim to establish non-contrast ultrasound as a clinically translatable imaging technique for spinal cord blood flow via comparison to contrast-based methods and by measuring the spatial distribution of blood flow after SCI. A rodent model of contusion SCI at the T12 spinal level was carried out using three different impact forces. We compared images of spinal cord blood flow taken using both non-contrast and contrast-enhanced ultrasound. Subsequently, we processed the images as a function of distance from injury, yielding the distribution of blood flow through space after SCI, and found the following. (1) Both non-contrast and contrast-enhanced imaging methods resulted in similar blood flow distributions (Spearman's ρ = 0.55, p < 0.0001). (2) We found an area of decreased flow at the injury epicenter, or umbra (p < 0.0001). Unexpectedly, we found increased flow at the periphery, or penumbra (rostral, p < 0.05; caudal, p < 0.01), following SCI. However, distal flow remained unchanged, in what is presumably unaffected tissue. (3) Finally, tracking blood flow in the injury zones over time revealed interesting dynamic changes. After an initial decrease, blood flow in the penumbra increased during the first 10 min after injury, while blood flow in the umbra and distal tissue remained constant over time. These results demonstrate the viability of non-contrast ultrasound as a clinical monitoring tool. Furthermore, our surprising observations of increased flow in the injury periphery pose interesting new questions about how the spinal cord vasculature reacts to SCI, with potentially increased significance of the penumbra.
Collapse
Affiliation(s)
- Denis Routkevitch
- Department of Biomedical Engineering, Johns Hopkins University, Baltimore, MD, USA
- Department of Neurosurgery, School of Medicine, Johns Hopkins University, Baltimore, MD, USA
- HEPIUS Innovation Laboratory, School of Medicine, Johns Hopkins University, Baltimore, MD, USA
| | - Zoe Soulé
- Department of Biomedical Engineering, Johns Hopkins University, Baltimore, MD, USA
| | - Nicholas Kats
- Department of Biomedical Engineering, Johns Hopkins University, Baltimore, MD, USA
| | - Emily Baca
- Department of Biomedical Engineering, Johns Hopkins University, Baltimore, MD, USA
| | - Andrew M Hersh
- Department of Neurosurgery, School of Medicine, Johns Hopkins University, Baltimore, MD, USA
- HEPIUS Innovation Laboratory, School of Medicine, Johns Hopkins University, Baltimore, MD, USA
| | - Kelley M Kempski-Leadingham
- Department of Neurosurgery, School of Medicine, Johns Hopkins University, Baltimore, MD, USA
- HEPIUS Innovation Laboratory, School of Medicine, Johns Hopkins University, Baltimore, MD, USA
| | - Arjun K Menta
- Department of Neurosurgery, School of Medicine, Johns Hopkins University, Baltimore, MD, USA
- HEPIUS Innovation Laboratory, School of Medicine, Johns Hopkins University, Baltimore, MD, USA
| | - Meghana Bhimreddy
- Department of Neurosurgery, School of Medicine, Johns Hopkins University, Baltimore, MD, USA
- HEPIUS Innovation Laboratory, School of Medicine, Johns Hopkins University, Baltimore, MD, USA
| | - Kelly Jiang
- Department of Neurosurgery, School of Medicine, Johns Hopkins University, Baltimore, MD, USA
- HEPIUS Innovation Laboratory, School of Medicine, Johns Hopkins University, Baltimore, MD, USA
| | - A Daniel Davidar
- Department of Neurosurgery, School of Medicine, Johns Hopkins University, Baltimore, MD, USA
- HEPIUS Innovation Laboratory, School of Medicine, Johns Hopkins University, Baltimore, MD, USA
| | - Constantin Smit
- HEPIUS Innovation Laboratory, School of Medicine, Johns Hopkins University, Baltimore, MD, USA
| | - Nicholas Theodore
- Department of Neurosurgery, School of Medicine, Johns Hopkins University, Baltimore, MD, USA
- HEPIUS Innovation Laboratory, School of Medicine, Johns Hopkins University, Baltimore, MD, USA
| | - Nitish V Thakor
- Department of Biomedical Engineering, Johns Hopkins University, Baltimore, MD, USA
- HEPIUS Innovation Laboratory, School of Medicine, Johns Hopkins University, Baltimore, MD, USA
- Department of Electrical and Computer Engineering, Johns Hopkins University, Baltimore, MD, USA
| | - Amir Manbachi
- Department of Biomedical Engineering, Johns Hopkins University, Baltimore, MD, USA.
- Department of Neurosurgery, School of Medicine, Johns Hopkins University, Baltimore, MD, USA.
- HEPIUS Innovation Laboratory, School of Medicine, Johns Hopkins University, Baltimore, MD, USA.
- Department of Electrical and Computer Engineering, Johns Hopkins University, Baltimore, MD, USA.
- Department of Mechanical Engineering, Johns Hopkins University, Baltimore, MD, USA.
- Department of Anesthesiology and Critical Care Medicine, School of Medicine, Johns Hopkins University, Baltimore, MD, USA.
| |
Collapse
|
17
|
Apfelbeck M, Loupas T, Chaloupka M, Clevert DA. Improved diagnostic confidence using Super Resolution CEUS imaging in testicular lesions. Clin Hemorheol Microcirc 2024; 88:S113-S125. [PMID: 39422932 PMCID: PMC11612930 DOI: 10.3233/ch-248109] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/19/2024]
Abstract
Ultrasound is the most used interdisciplinary non-ionizing imaging technique in clinical pathologies of the testis. The testis may be affected by a plethora of different disorders such as vasculopathies, trauma, infections and manifestations of primary and secondary malignant masses. Conventional ultrasound represents the basic imaging modality of choice to assess scrotal disorders. Contrast-enhanced ultrasound (CEUS) can provide further information to distinguish between benign and malignant testicular mass lesions. The recent introduction of Super Resolution CEUS Micro-Vascular Imaging (MVI SR) and Time of Arrival (TOA SR) parametric mapping compliments the information provided by conventional CEUS, since these two new post-processing techniques improve the visualization of microvascular structures with slow blood flow and provide high-resolution images of the peak contrast enhancement and temporal perfusion patterns. This paper gives a comprehensive overview of differential diagnoses of the testicular disorder and their corresponding sono-morphologic correlates based on representative cases of the Interdisciplinary Ultrasound Center of the University Hospital Munich.
Collapse
Affiliation(s)
| | | | | | - Dirk-André Clevert
- Department of Radiology, Ludwig-Maximilians-University Munich, Munich, Germany
- Interdisciplinary Ultrasound-Center, Ludwig-Maximilians-University Munich, Munich, Germany
| |
Collapse
|
18
|
Gao Y, Zeng X, Liao X. Correlation between microvessel maturity and ISUP grades assessed using contrast-enhanced transrectal ultrasonography in prostate cancer. Open Med (Wars) 2023; 18:20230772. [PMID: 37588658 PMCID: PMC10426265 DOI: 10.1515/med-2023-0772] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/16/2022] [Revised: 06/27/2023] [Accepted: 07/19/2023] [Indexed: 08/18/2023] Open
Abstract
This study aimed to assess the correlation among the peak intensity (PI) values of quantitative parameters, microvessel density (MVD), microvessel maturity, and International Society of Urological Pathology (ISUP) grades in biopsy specimens from prostate cancer (PCa) patients. The study population included PCa patients who underwent targeted and systematic biopsy, without radiation or chemohormonal therapy before biopsy. Contrast-enhanced transrectal ultrasonography (CE-TRUS) was performed in all patients before biopsy. Contrast-enhancement patterns and PI values of quantitative parameters were observed. Tumor tissue samples were immunostained for CD31 expression. MVD, microvessel maturity, and ISUP grades were determined in prostate biopsy specimens. Based on the contrast enhancement patterns of prostate lesions, 16 patients were assigned to a low-enhancement group and 45 to a high-enhancement group. The number of mature vessels, MVD, mature vessel index, and ISUP grades were all higher in the high-enhancement group than in the low-enhancement group (all P < 0.05). The immature vessel index was lower in the high-enhancement group than in the low-enhancement group (P < 0.05). The PI value was positively correlated with the number of mature vessels (r = 0.372). In conclusion, enhancement patterns on CE-TRUS can reflect microvessel maturity in PCa. The PI value was positively correlated with the number of mature vessels.
Collapse
Affiliation(s)
- Yong Gao
- Department of Ultrasound, First Affiliated Hospital of Guangxi Medical University, 530021Guangxi, China
| | - Xuerong Zeng
- Department of Ultrasound, First Affiliated Hospital of Guangxi Medical University, 530021Guangxi, China
| | - Xinhong Liao
- Department of Ultrasound, First Affiliated Hospital of Guangxi Medical University, 6 Shuangyong Rd,
Nanning, 530021Guangxi, China
| |
Collapse
|
19
|
Dencks S, Schmitz G. Ultrasound localization microscopy. Z Med Phys 2023; 33:292-308. [PMID: 37328329 PMCID: PMC10517400 DOI: 10.1016/j.zemedi.2023.02.004] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/11/2022] [Revised: 01/24/2023] [Accepted: 02/10/2023] [Indexed: 06/18/2023]
Abstract
Ultrasound Localization Microscopy (ULM) is an emerging technique that provides impressive super-resolved images of microvasculature, i.e., images with much better resolution than the conventional diffraction-limited ultrasound techniques and is already taking its first steps from preclinical to clinical applications. In comparison to the established perfusion or flow measurement methods, namely contrast-enhanced ultrasound (CEUS) and Doppler techniques, ULM allows imaging and flow measurements even down to the capillary level. As ULM can be realized as a post-processing method, conventional ultrasound systems can be used for. ULM relies on the localization of single microbubbles (MB) of commercial, clinically approved contrast agents. In general, these very small and strong scatterers with typical radii of 1-3 µm are imaged much larger in ultrasound images than they actually are due to the point spread function of the imaging system. However, by applying appropriate methods, these MBs can be localized with sub-pixel precision. Then, by tracking MBs over successive frames of image sequences, not only the morphology of vascular trees but also functional information such as flow velocities or directions can be obtained and visualized. In addition, quantitative parameters can be derived to describe pathological and physiological changes in the microvasculature. In this review, the general concept of ULM and conditions for its applicability to microvessel imaging are explained. Based on this, various aspects of the different processing steps for a concrete implementation are discussed. The trade-off between complete reconstruction of the microvasculature and the necessary measurement time as well as the implementation in 3D are reviewed in more detail, as they are the focus of current research. Through an overview of potential or already realized preclinical and clinical applications - pathologic angiogenesis or degeneration of vessels, physiological angiogenesis, or the general understanding of organ or tissue function - the great potential of ULM is demonstrated.
Collapse
Affiliation(s)
- Stefanie Dencks
- Lehrstuhl für Medizintechnik, Fakultät für Elektrotechnik und Informationstechnik, Ruhr-Universität Bochum, Bochum, Germany.
| | - Georg Schmitz
- Lehrstuhl für Medizintechnik, Fakultät für Elektrotechnik und Informationstechnik, Ruhr-Universität Bochum, Bochum, Germany
| |
Collapse
|
20
|
Song P, Rubin JM, Lowerison MR. Super-resolution ultrasound microvascular imaging: Is it ready for clinical use? Z Med Phys 2023; 33:309-323. [PMID: 37211457 PMCID: PMC10517403 DOI: 10.1016/j.zemedi.2023.04.001] [Citation(s) in RCA: 29] [Impact Index Per Article: 14.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/08/2022] [Revised: 03/31/2023] [Accepted: 04/01/2023] [Indexed: 05/23/2023]
Abstract
The field of super-resolution ultrasound microvascular imaging has been rapidly growing over the past decade. By leveraging contrast microbubbles as point targets for localization and tracking, super-resolution ultrasound pinpoints the location of microvessels and measures their blood flow velocity. Super-resolution ultrasound is the first in vivo imaging modality that can image micron-scale vessels at a clinically relevant imaging depth without tissue destruction. These unique capabilities of super-resolution ultrasound provide structural (vessel morphology) and functional (vessel blood flow) assessments of tissue microvasculature on a global and local scale, which opens new doors for many enticing preclinical and clinical applications that benefit from microvascular biomarkers. The goal of this short review is to provide an update on recent advancements in super-resolution ultrasound imaging, with a focus on summarizing existing applications and discussing the prospects of translating super-resolution imaging to clinical practice and research. In this review, we also provide brief introductions of how super-resolution ultrasound works, how does it compare with other imaging modalities, and what are the tradeoffs and limitations for an audience who is not familiar with the technology.
Collapse
Affiliation(s)
- Pengfei Song
- Department of Electrical and Computer Engineering, University of Illinois Urbana-Champaign, United States; Beckman Institute for Advanced Science and Technology, University of Illinois Urbana-Champaign, United States; Department of Bioengineering, University of Illinois Urbana-Champaign, United States; Carle Illinois College of Medicine, University of Illinois Urbana-Champaign, United States.
| | - Jonathan M Rubin
- Department of Radiology, University of Michigan, Ann Arbor, United States
| | - Matthew R Lowerison
- Department of Electrical and Computer Engineering, University of Illinois Urbana-Champaign, United States; Beckman Institute for Advanced Science and Technology, University of Illinois Urbana-Champaign, United States
| |
Collapse
|
21
|
Moghimirad E, Xu Z, Ding H, Bamber J, Harris E. Evaluation of Performance Tradeoffs When Using Mechanically Swept 1-D Linear Arrays for 3-D DCE-US. IEEE TRANSACTIONS ON ULTRASONICS, FERROELECTRICS, AND FREQUENCY CONTROL 2023; 70:681-692. [PMID: 37067961 DOI: 10.1109/tuffc.2023.3268009] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/19/2023]
Abstract
Dynamic contrast-enhanced ultrasound imaging (DCE-US) may be used to characterize tumor vascular perfusion using metrics derived from time-amplitude curves (TACs). The 3-D DCE-US enables generation of 3-D parametric maps of TAC metrics that may inform on how perfusion varies across the entire tumor. The aim of this work was to understand the effect of low temporal sampling (i.e., < 1 Hz) typical of 3-D imaging using a swept 1-D array transducer on the evaluation of TAC metrics and the effect of transducer motion in combination with flow on 3-D parametric maps generated using both plane wave imaging (PWI) (seven angles) and focused imaging (FI). Correlation maps were introduced to evaluate the spatial blurring of TAC metrics. A research ultrasound scanner and a pulse-inversion algorithm were used to obtain DCE-US. The 2-D (frame rate 10 Hz) and 3-D (volume rate 0.4 Hz) images were acquired of a simple wall-less vessel phantom (flow phantom) and a cartridge phantom. Volumetric imaging provided similar TACs to that of the higher 2-D sampling rate. Varying sweep speed and acceleration/deceleration had little influence on the 3-D TAC compared to 2-D for both FI and PWI. Sweeping motion and limited temporal sampling (0.4 Hz) did not change the spatial correlation of TAC metrics measured using FI, whereas a small increase in correlation across the cartridge phantom was observed for PWI. This was attributed to grating lobe artifacts, broad beam spatial blurring, and incoherent compounding caused by motion. Increased correlation will reduce the spatial resolution with which inhomogeneity of vascular perfusion can be mapped supporting the choice of FI for DCE-US.
Collapse
|
22
|
Xue ES, Su HZ, Li ZY, Hong LC, Lin WJ, Chen C, Guo J, Fang ZY. Contrast-Enhanced Ultrasound Imaging: Novel Method for the Evaluation of Chronic Alcohol-Induced Testicular Damage. ULTRASOUND IN MEDICINE & BIOLOGY 2023:S0301-5629(23)00165-5. [PMID: 37271681 DOI: 10.1016/j.ultrasmedbio.2023.05.007] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 02/25/2023] [Revised: 05/08/2023] [Accepted: 05/11/2023] [Indexed: 06/06/2023]
Abstract
OBJECTIVE The goals of this study were to determine whether contrast-enhanced ultrasound (CEUS) imaging could be used for assessment of chronic alcohol-induced testicular damage (CAITD) and to explore the relationships between the laboratory and pathological findings of CAITD and the quantitative parameters of CEUS. METHODS Thirty-six rabbits were randomly divided into a chronic ethanol exposure (CEE) group and negative control (NC) group, which were further randomly divided into six groups with equal numbers of rabbits by period of exposure (30 d, 60 d, 90 d). All rabbits underwent conventional US and CEUS imaging at the end of the induction period. Blood and histological specimens were collected for laboratory and pathological examination. RESULTS The peak intensity (PI) and area under the curve (AUC) for the CEUS parameters decreased as CAITD progressed (p < 0.05). Both PI and AUC were positively correlated with the Johnsen score (r= 0.945 and 0.898, respectively, all p values <0.001) and the mean epithelium thickness of the seminiferous tubule (METST) (r= 0.927 and 0.881, respectively, all p values <0.001) of the testis, and negatively correlated with the serum levels of endothelin-1 (ET-1) (r = -0.940 and -0.899, respectively, all p values <0.001) and nitric oxide (NO) (r = -0.894 and -0.954, respectively, all p values <0.001), as well as the testicular tissue content of malondialdehyde (MDA) (r = -0.894 and -0.945, respectively, all p values <0.001). CONCLUSION CEUS imaging can be used for monitoring organ perfusion of the testis to quantify the development of CAITD.
Collapse
Affiliation(s)
- En-Sheng Xue
- Department of Ultrasound, Fujian Medical University Union Hospital, Fuzhou, China.
| | - Huan-Zhong Su
- Department of Ultrasound, The First Affiliated Hospital of Xiamen University, Xiamen, China
| | - Zhi-Yong Li
- Department of Ultrasound, Fujian Medical University Union Hospital, Fuzhou, China
| | - Long-Cheng Hong
- Department of Ultrasound, The First Affiliated Hospital of Xiamen University, Xiamen, China
| | - Wen-Jin Lin
- Department of Ultrasound, Fujian Medical University Union Hospital, Fuzhou, China
| | - Cong Chen
- Department of Ultrasound, Fujian Medical University Union Hospital, Fuzhou, China
| | - Jie Guo
- Department of Ultrasound, Fujian Maternity and Child Health Hospital, Fuzhou, China
| | - Zhen-Yan Fang
- Department of Ultrasound, Fujian Medical University Union Hospital, Fuzhou, China
| |
Collapse
|
23
|
Feliciano MAR, de Miranda BDSP, Aires LPN, Lima BB, de Oliveira APL, Feliciano GSM, Uscategui RAR. The Importance of Ultrasonography in the Evaluation of Mammary Tumors in Bitches. Animals (Basel) 2023; 13:1742. [PMID: 37889644 PMCID: PMC10252055 DOI: 10.3390/ani13111742] [Citation(s) in RCA: 2] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/26/2023] [Revised: 04/11/2023] [Accepted: 04/14/2023] [Indexed: 10/29/2023] Open
Abstract
The high incidence of mammary tumors in small animals is concerning. Patient history, clinical examination, physical evaluation, and imaging studies are important for clinical staging. Ultrasonography is commonly applied to investigate the presence of abdominal metastasis. However, it has been shown to provide important information regarding mammary tumors' architecture and advanced sonographic techniques can provide information regarding neovascularization, stiffness, and perfusion. Different techniques have been investigated to determine accuracy to predict the lesions' histological classification. This paper reviews the information regarding each sonographic technique in the evaluation of mammary tumors, describing the most common findings and their potential to accurately assess and predict malignancy. Even though the gold standard for the diagnosis of mammary lesions is the histopathological examination, some ultrasonographic features described can predict the potential of a lesion being malignant. Among the different sonographic techniques, elastography can be considered the most reliable modality to accurately differentiate benign from malignant tumors when malignant lesions present increased stiffness. However, the combination of all sonographic techniques can provide important information that can lead to a better therapeutic approach and clinical staging. Furthermore, the potential of the sonographic study, especially CEUS to monitor therapeutic progression, demonstrate the need of further studies.
Collapse
Affiliation(s)
- Marcus Antônio Rossi Feliciano
- Laboratory of Veterinary Imaginology, Faculty of Animal Science and Food Engineering (FZEA), Sao Paulo University (USP), Pirassununga 13635-900, Sao Paulo, Brazil
| | - Brenda dos Santos Pompeu de Miranda
- Department of Veterinary Clinic and Surgery, School of Agricultural and Veterinarian Sciences, Sao Paulo State University “Júlio de Mesquita Filho” (FCAV/UNESP), Jaboticabal 14884-900, Sao Paulo, Brazil
| | - Luiz Paulo Nogueira Aires
- Department of Veterinary Clinic and Surgery, School of Agricultural and Veterinarian Sciences, Sao Paulo State University “Júlio de Mesquita Filho” (FCAV/UNESP), Jaboticabal 14884-900, Sao Paulo, Brazil
| | - Bruna Bressianini Lima
- Department of Veterinary Clinic and Surgery, School of Agricultural and Veterinarian Sciences, Sao Paulo State University “Júlio de Mesquita Filho” (FCAV/UNESP), Jaboticabal 14884-900, Sao Paulo, Brazil
| | - Ana Paula Luiz de Oliveira
- Department of Veterinary Clinic and Surgery, School of Agricultural and Veterinarian Sciences, Sao Paulo State University “Júlio de Mesquita Filho” (FCAV/UNESP), Jaboticabal 14884-900, Sao Paulo, Brazil
| | - Giovanna Serpa Maciel Feliciano
- Laboratory of Veterinary Imaginology, Faculty of Animal Science and Food Engineering (FZEA), Sao Paulo University (USP), Pirassununga 13635-900, Sao Paulo, Brazil
| | | |
Collapse
|
24
|
Sojahrood AJ, Li Q, Haghi H, Karshafian R, Porter TM, Kolios MC. Probing the pressure dependence of sound speed and attenuation in bubbly media: Experimental observations, a theoretical model and numerical calculations. ULTRASONICS SONOCHEMISTRY 2023; 95:106319. [PMID: 36931196 PMCID: PMC11487347 DOI: 10.1016/j.ultsonch.2023.106319] [Citation(s) in RCA: 23] [Impact Index Per Article: 11.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 10/26/2022] [Revised: 01/18/2023] [Accepted: 02/01/2023] [Indexed: 06/18/2023]
Abstract
The problem of attenuation and sound speed of bubbly media has remained partially unsolved. Comprehensive data regarding pressure-dependent changes of the attenuation and sound speed of a bubbly medium are not available. Our theoretical understanding of the problem is limited to linear or semi-linear theoretical models, which are not accurate in the regime of large amplitude bubble oscillations. Here, by controlling the size of the lipid coated bubbles (mean diameter of ≈5.4μm), we report the first time observation and characterization of the simultaneous pressure dependence of sound speed and attenuation in bubbly water below, at and above microbubbles resonance (frequency range between 1-3 MHz). With increasing acoustic pressure (between 12.5-100 kPa), the frequency of the peak attenuation and sound speed decreases while maximum and minimum amplitudes of the sound speed increase. We propose a nonlinear model for the estimation of the pressure dependent sound speed and attenuation with good agreement with the experiments. The model calculations are validated by comparing with the linear and semi-linear models predictions. One of the major challenges of the previously developed models is the significant overestimation of the attenuation at the bubble resonance at higher void fractions (e.g. 0.005). We addressed this problem by incorporating bubble-bubble interactions and comparing the results to experiments. Influence of the bubble-bubble interactions increases with increasing pressure. Within the examined exposure parameters, we numerically show that, even for low void fractions (e.g. 5.1×10-6) with increasing pressure the sound speed may become 4 times higher than the sound speed in the non-bubbly medium.
Collapse
Affiliation(s)
- A J Sojahrood
- Department of Physics, Toronto Metropolitan University, Toronto, Canada; Institute for Biomedical Engineering, Science and Technology (IBEST) a partnership between Ryerson University and St. Mike's Hospital, Toronto, Ontario, Canada.
| | - Q Li
- Department of Biomedical Engineering, Boston University, Boston, MA, USA
| | - H Haghi
- Department of Physics, Toronto Metropolitan University, Toronto, Canada; Institute for Biomedical Engineering, Science and Technology (IBEST) a partnership between Ryerson University and St. Mike's Hospital, Toronto, Ontario, Canada
| | - R Karshafian
- Department of Physics, Toronto Metropolitan University, Toronto, Canada; Institute for Biomedical Engineering, Science and Technology (IBEST) a partnership between Ryerson University and St. Mike's Hospital, Toronto, Ontario, Canada
| | - T M Porter
- Department of Biomedical Engineering, Boston University, Boston, MA, USA; Department of Biomedical Engineering, University of Texas at Austin, Texas, USA
| | - M C Kolios
- Department of Physics, Toronto Metropolitan University, Toronto, Canada; Institute for Biomedical Engineering, Science and Technology (IBEST) a partnership between Ryerson University and St. Mike's Hospital, Toronto, Ontario, Canada.
| |
Collapse
|
25
|
Chen SY, Wang YW, Chen WS, Hsiao MY. Update of Contrast-enhanced Ultrasound in Musculoskeletal Medicine: Clinical Perspectives - A Review. J Med Ultrasound 2023; 31:92-100. [PMID: 37576422 PMCID: PMC10413398 DOI: 10.4103/jmu.jmu_94_22] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/19/2022] [Revised: 10/03/2022] [Accepted: 10/07/2022] [Indexed: 08/15/2023] Open
Abstract
Contrast-enhanced ultrasound (CEUS) uses an intravascular contrast agent to enhance blood flow signals and assess microcirculation in different parts of the human body. Over the past decade, CEUS has become more widely applied in musculoskeletal (MSK) medicine, and the current review aims to systematically summarize current research on the application of CEUS in the MSK field, focusing on 67 articles published between January 2001 and June 2021 in online databases including PubMed, Scopus, and Embase. CEUS has been widely used for the clinical assessment of muscle microcirculation, tendinopathy, fracture nonunions, sports-related injuries, arthritis, peripheral nerves, and tumors, and can serve as an objective and quantitative evaluation tool for prognosis and outcome prediction. Optimal CEUS parameters and diagnostic cut off values for each disease category remain to be confirmed.
Collapse
Affiliation(s)
- Shao-Yu Chen
- Department of Physical Medicine and Rehabilitation, National Taiwan University Hospital, Taipei, Taiwan
| | - Yao-Wei Wang
- Department of Physical Medicine and Rehabilitation, National Taiwan University Hospital, Taipei, Taiwan
| | - Wen-Shiang Chen
- Department of Physical Medicine and Rehabilitation, National Taiwan University Hospital, Taipei, Taiwan
- Department of Physical Medicine and Rehabilitation, College of Medicine, National Taiwan University, Taipei, Taiwan
| | - Ming-Yen Hsiao
- Department of Physical Medicine and Rehabilitation, National Taiwan University Hospital, Taipei, Taiwan
- Department of Physical Medicine and Rehabilitation, College of Medicine, National Taiwan University, Taipei, Taiwan
| |
Collapse
|
26
|
Øygard SH, Ommen ML, Tomov BG, Diederichsen SE, Thomsen EV, Stuart MB, Larsen NB, Jensen JA. Contrast-enhanced ultrasound imaging using capacitive micromachined ultrasonic transducers. THE JOURNAL OF THE ACOUSTICAL SOCIETY OF AMERICA 2023; 153:1887. [PMID: 37002075 DOI: 10.1121/10.0017533] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 11/13/2022] [Accepted: 02/20/2023] [Indexed: 05/18/2023]
Abstract
Capacitive micromachined ultrasonic transducers (CMUTs) have a nonlinear relationship between the applied voltage and the emitted signal, which is detrimental to conventional contrast enhanced ultrasound (CEUS) techniques. Instead, a three-pulse amplitude modulation (AM) sequence has been proposed, which is not adversely affected by the nonlinearly emitted harmonics. In this paper, this is shown theoretically, and the performance of the sequence is verified using a 4.8 MHz linear capacitive micromachined ultrasonic transducer (CMUT) array, and a comparable lead zirconate titanate (PZT) array, across 6-60 V applied alternating current (AC) voltage. CEUS images of the contrast agent SonoVue flowing through a 3D printed hydrogel phantom showed an average enhancement in contrast-to-tissue ratio (CTR) between B-mode and CEUS images of 49.9 and 37.4 dB for the PZT array and CMUT, respectively. Furthermore, hydrophone recordings of the emitted signals showed that the nonlinear emissions from the CMUT did not significantly degrade the cancellation in the compounded AM signal, leaving an average of 2% of the emitted power between 26 and 60 V of AC. Thus, it is demonstrated that CMUTs are capable of CEUS imaging independent of the applied excitation voltage when using a three-pulse AM sequence.
Collapse
Affiliation(s)
- Sigrid Husebø Øygard
- Department of Health Technology, Technical University of Denmark, DK-2800 Lyngby, Denmark
| | - Martin Lind Ommen
- Department of Health Technology, Technical University of Denmark, DK-2800 Lyngby, Denmark
| | | | | | - Erik Vilain Thomsen
- Department of Health Technology, Technical University of Denmark, DK-2800 Lyngby, Denmark
| | - Matthias Bo Stuart
- Department of Health Technology, Technical University of Denmark, DK-2800 Lyngby, Denmark
| | - Niels Bent Larsen
- Department of Health Technology, Technical University of Denmark, DK-2800 Lyngby, Denmark
| | - Jørgen Arendt Jensen
- Department of Health Technology, Technical University of Denmark, DK-2800 Lyngby, Denmark
| |
Collapse
|
27
|
Fetzer DT, Vijay K, Caserta MP, Patterson-Lachowicz A, Dahiya N, Rodgers SK. Artifacts and Technical Considerations at Contrast-enhanced US. Radiographics 2023; 43:e220093. [PMID: 36563094 DOI: 10.1148/rg.220093] [Citation(s) in RCA: 7] [Impact Index Per Article: 3.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/24/2022]
Abstract
Contrast-enhanced US (CEUS), similar to other radiologic modalities, requires specific technical considerations and is subject to image artifacts. These artifacts may affect examination quality, negatively impact diagnostic accuracy, and decrease user comfort when using this emerging technique. Some artifacts are related to commonly known gray-scale US artifacts that can also appear on the contrast-only image (tissue-subtracted image obtained with the linear responses from background tissues nulled). These may include acoustic shadowing and enhancement; reverberation, refraction, and reflection; and poor penetration. Other artifacts are exclusive to CEUS owing to the techniques used for contrast mode image generation and the unique properties of the microbubbles that constitute ultrasound-specific contrast agents (UCAs). UCA-related artifacts may appear on the contrast-only image, the gray-scale image, or various Doppler mode images. Artifacts related to CEUS may include nonlinear artifacts and unintentional microbubble destruction resulting in pseudowashout. The microbubbles themselves may result in specific artifacts such as pseudoenhancement, signal saturation, and attenuation and shadowing and can confound the use of color and spectral Doppler US. Identifying and understanding these artifacts and knowing how to mitigate them may improve the quality of the imaging study, increase user confidence, and improve patient care. The authors review the principles of UCAs and the sound-microbubble interaction, as well as the technical aspects of image generation. Technical considerations, including patient positioning, depth, acoustic window, and contrast agent dose, also are discussed. Specific artifacts are described, with tips on how to identify and, if necessary, apply corrective measures, with the goal of improving examination quality. © RSNA, 2022 Online supplemental material and the slide presentation from the RSNA Annual Meeting are available for this article.
Collapse
Affiliation(s)
- David T Fetzer
- From the Department of Radiology, UT Southwestern Medical Center, 5323 Harry Hines Blvd, E6-230-BF, Dallas, TX 75390-8896 (D.T.F., K.V., A.P.L.); Department of Radiology, Mayo Clinic, Jacksonville, FL (M.P.C.); Department of Radiology, Mayo Clinic, Phoenix, AZ (N.D.); and Department of Radiology, Jefferson Health New Jersey, Thomas Jefferson University, Cherry Hill, NJ (S.K.R.)
| | - Kanupriya Vijay
- From the Department of Radiology, UT Southwestern Medical Center, 5323 Harry Hines Blvd, E6-230-BF, Dallas, TX 75390-8896 (D.T.F., K.V., A.P.L.); Department of Radiology, Mayo Clinic, Jacksonville, FL (M.P.C.); Department of Radiology, Mayo Clinic, Phoenix, AZ (N.D.); and Department of Radiology, Jefferson Health New Jersey, Thomas Jefferson University, Cherry Hill, NJ (S.K.R.)
| | - Melanie P Caserta
- From the Department of Radiology, UT Southwestern Medical Center, 5323 Harry Hines Blvd, E6-230-BF, Dallas, TX 75390-8896 (D.T.F., K.V., A.P.L.); Department of Radiology, Mayo Clinic, Jacksonville, FL (M.P.C.); Department of Radiology, Mayo Clinic, Phoenix, AZ (N.D.); and Department of Radiology, Jefferson Health New Jersey, Thomas Jefferson University, Cherry Hill, NJ (S.K.R.)
| | - Amber Patterson-Lachowicz
- From the Department of Radiology, UT Southwestern Medical Center, 5323 Harry Hines Blvd, E6-230-BF, Dallas, TX 75390-8896 (D.T.F., K.V., A.P.L.); Department of Radiology, Mayo Clinic, Jacksonville, FL (M.P.C.); Department of Radiology, Mayo Clinic, Phoenix, AZ (N.D.); and Department of Radiology, Jefferson Health New Jersey, Thomas Jefferson University, Cherry Hill, NJ (S.K.R.)
| | - Nirvikar Dahiya
- From the Department of Radiology, UT Southwestern Medical Center, 5323 Harry Hines Blvd, E6-230-BF, Dallas, TX 75390-8896 (D.T.F., K.V., A.P.L.); Department of Radiology, Mayo Clinic, Jacksonville, FL (M.P.C.); Department of Radiology, Mayo Clinic, Phoenix, AZ (N.D.); and Department of Radiology, Jefferson Health New Jersey, Thomas Jefferson University, Cherry Hill, NJ (S.K.R.)
| | - Shuchi K Rodgers
- From the Department of Radiology, UT Southwestern Medical Center, 5323 Harry Hines Blvd, E6-230-BF, Dallas, TX 75390-8896 (D.T.F., K.V., A.P.L.); Department of Radiology, Mayo Clinic, Jacksonville, FL (M.P.C.); Department of Radiology, Mayo Clinic, Phoenix, AZ (N.D.); and Department of Radiology, Jefferson Health New Jersey, Thomas Jefferson University, Cherry Hill, NJ (S.K.R.)
| |
Collapse
|
28
|
Characterization of spatially mapped volumetric molecular ultrasound signals for predicting response to anti-vascular therapy. Sci Rep 2023; 13:1686. [PMID: 36717575 PMCID: PMC9886917 DOI: 10.1038/s41598-022-26273-0] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/03/2022] [Accepted: 12/13/2022] [Indexed: 01/31/2023] Open
Abstract
Quantitative three-dimensional molecular ultrasound is a promising technology for longitudinal imaging applications such as therapy monitoring; the risk profile is favorable compared to positron emission tomography and computed tomography. However, clinical translation of quantitative methods for this technology are limited in that they assume that tumor tissues are homogeneous, and often depend on contrast-destruction events that can produce unintended bioeffects. Here, we develop quantitative features (henceforth image features) that capture tumor spatial information, and that are extracted without contrast destruction. We compare these techniques with the contrast-destruction derived differential targeted enhancement parameter (dTE) in predicting response to therapy. We found thirty-three reproducible image features that predict response to antiangiogenic therapy, without the need for a contrast agent disruption pulse. Multiparametric analysis shows that several of these image features can differentiate treated versus control animals with comparable performance to post-destruction measurements, suggesting that these can potentially replace parameters such as the dTE. The highest performing pre-destruction image features showed strong linear correlations with conventional dTE parameters with less overall variance. Thus, our study suggests that image features obtained during the wash in of the molecular agent, pre-destruction, may replace conventional post-destruction image features or the dTE parameter.
Collapse
|
29
|
Cheng H, Zhang J, Gong Y, Pu Z, Jiang J, Chu Y, Xia L. Semantic segmentation method for myocardial contrast echocardiogram based on DeepLabV3+ deep learning architecture. MATHEMATICAL BIOSCIENCES AND ENGINEERING : MBE 2023; 20:2081-2093. [PMID: 36899523 DOI: 10.3934/mbe.2023096] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/18/2023]
Abstract
Myocardial contrast echocardiography (MCE) has been proposed as a method to assess myocardial perfusion for the detection of coronary artery diseases in a non-invasive way. As a critical step of automatic MCE perfusion quantification, myocardium segmentation from the MCE frames faces many challenges due to the low image quality and complex myocardial structure. In this paper, a deep learning semantic segmentation method is proposed based on a modified DeepLabV3+ structure with an atrous convolution and atrous spatial pyramid pooling module. The model was trained separately on three chamber views (apical two-chamber view, apical three-chamber view, and apical four-chamber view) on 100 patients' MCE sequences, divided by a proportion of 7:3 into training and testing datasets. The results evaluated by using the dice coefficient (0.84, 0.84, and 0.86 for three chamber views respectively) and Intersection over Union(0.74, 0.72 and 0.75 for three chamber views respectively) demonstrated the better performance of the proposed method compared to other state-of-the-art methods, including the original DeepLabV3+, PSPnet, and U-net. In addition, we conducted a trade-off comparison between model performance and complexity in different depths of the backbone convolution network, which illustrated model application feasibility.
Collapse
Affiliation(s)
- Huan Cheng
- Key Laboratory for Biomedical Engineering of Ministry of Education, Institute of Biomedical Engineering, Zhejiang University, Hangzhou 310027, China
| | - Jucheng Zhang
- Department of Clinical Engineering, School of Medicine, The Second Affiliated Hospital, Zhejiang University, Hangzhou 310009, China
| | - Yinglan Gong
- Institute of Wenzhou, Zhejiang University, Wenzhou 325036, China
| | - Zhaoxia Pu
- Department of Cardiology, School of Medicine, The Second Affiliated Hospital, Zhejiang University, Hangzhou 310009, China
| | - Jun Jiang
- Department of Cardiology, School of Medicine, The Second Affiliated Hospital, Zhejiang University, Hangzhou 310009, China
| | - Yonghua Chu
- Department of Clinical Engineering, School of Medicine, The Second Affiliated Hospital, Zhejiang University, Hangzhou 310009, China
| | - Ling Xia
- Key Laboratory for Biomedical Engineering of Ministry of Education, Institute of Biomedical Engineering, Zhejiang University, Hangzhou 310027, China
| |
Collapse
|
30
|
Wu J, Qiao H. Medical Imaging Technology and Imaging Agents. ADVANCES IN EXPERIMENTAL MEDICINE AND BIOLOGY 2023; 1199:15-38. [PMID: 37460725 DOI: 10.1007/978-981-32-9902-3_2] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 07/20/2023]
Abstract
Medical imaging is a technology that studies the interaction between human body and irradiations of X-ray, ultrasound, magnetic field, etc. and represents anatomical structures of human organs/tissues with the implication of irradiation attenuation in the form of grayscales. With these medical images, detailed information on health status and disease diagnosis may be judged by clinical physicians to determine an appropriate therapy approach. This chapter will give a systematic introduction on the modalities, classifications, basic principles, and biomedical applications of traditional medical imaging along with the types, construction, and major features of the corresponding contrast agents or imaging probes.
Collapse
Affiliation(s)
- Jieting Wu
- Academy of Medical Engineering and Translational Medicine, Tianjin University, Tianjin, China
| | - Huanhuan Qiao
- Academy of Medical Engineering and Translational Medicine, Tianjin University, Tianjin, China.
| |
Collapse
|
31
|
Intra- and Inter-Observer Variability of Quantitative Parameters Used in Contrast-Enhanced Ultrasound of Kidneys of Healthy Cats. Animals (Basel) 2022; 12:ani12243557. [PMID: 36552476 PMCID: PMC9774712 DOI: 10.3390/ani12243557] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/29/2022] [Revised: 12/05/2022] [Accepted: 12/13/2022] [Indexed: 12/23/2022] Open
Abstract
Contrast-enhanced ultrasound (CEUS) is a non-invasive imaging technique which allows qualitative and quantitative assessment of tissue perfusion. Although CEUS offers numerous advantages, a major challenge remains the variability in tissue perfusion quantification. This study aimed to assess intra- and inter-observer variability for quantification of renal perfusion. Two observers with different levels of expertise performed a quantitative analysis of 36 renal CEUS studies, twice. The CEUS data were collected from 12 healthy cats at 3 different time points with a 7-day interval. The inter- and intra-observer agreement was assessed by the intraclass correlation coefficient. Within and between observers, a good agreement was demonstrated for intensity-related parameters in the cortex, medulla, and interlobular artery. For some parameters, ICCinter was considerably lower than ICCintra, mostly when the ROI encompassed the entire kidney or medulla. With the exception of time to peak (TTP) and mean transit time (mTTI), time-related and slope-related parameters showed poor agreement among observers. In conclusion, it may be advised against having the quantitative assessment of renal perfusion performed by different observers, especially if their experience levels differ. The cortical mTTI seemed to be the most appropriate parameter as it showed a favorable inter-observer agreement and inter-period agreement.
Collapse
|
32
|
Nogueira Aires LP, Gasser B, Silva P, Del’Aguila-Silva P, Yamada DI, Carneiro RK, Bressianini Lima B, Padilha-Nakaghi LC, Ramirez Uscategui RA, Spada S, Russo M, Rossi Feliciano MA. Ovarian contrast-enhanced ultrasonography and Doppler fluxometry in bitches during the postovulatory estrus and corpora lutea formation. Theriogenology 2022; 194:162-170. [DOI: 10.1016/j.theriogenology.2022.10.009] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/26/2022] [Revised: 10/06/2022] [Accepted: 10/07/2022] [Indexed: 11/06/2022]
|
33
|
Zhu J, Zhang C, Christensen-Jeffries K, Zhang G, Harput S, Dunsby C, Huang P, Tang MX. Super-Resolution Ultrasound Localization Microscopy of Microvascular Structure and Flow for Distinguishing Metastatic Lymph Nodes - An Initial Human Study. ULTRASCHALL IN DER MEDIZIN (STUTTGART, GERMANY : 1980) 2022; 43:592-598. [PMID: 36206774 DOI: 10.1055/a-1917-0016] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/16/2023]
Abstract
PURPOSE Detecting and distinguishing metastatic lymph nodes (LNs) from those with benign lymphadenopathy are crucial for cancer diagnosis and prognosis but remain a clinical challenge. A recent advance in super-resolution ultrasound (SRUS) through localizing individual microbubbles has broken the diffraction limit and tracking enabled in vivo noninvasive imaging of vascular morphology and flow dynamics at a microscopic level. In this study we hypothesize that SRUS enables quantitative markers to distinguish metastatic LNs from benign ones in patients with lymphadenopathy. MATERIALS AND METHODS Clinical contrast-enhanced ultrasound image sequences of LNs from 6 patients with lymph node metastasis and 4 with benign lymphadenopathy were acquired and motion-corrected. These were then used to generate super-resolution microvascular images and super-resolved velocity maps. From these SRUS images, morphological and functional measures were obtained including micro-vessel density, fractal dimension, mean flow speed, and Local Flow Direction Irregularity (LFDI) measuring the variance in local flow direction. These measures were compared between pathologically proven reactive and metastasis LNs. RESULTS Our initial results indicate that the difference in the indicator of flow irregularity (LFDI) derived from the SRUS images is statistically significant between the two groups. The LFDI is 60% higher in metastatic LNs compared with reactive nodes. CONCLUSION This pilot study demonstrates the feasibility of super-resolution ultrasound for clinical imaging of lymph nodes and the potential of using the irregularity of local blood flow directions afforded by SRUS for the characterization of LNs.
Collapse
Affiliation(s)
- Jiaqi Zhu
- Bioengineering, Imperial College London, London, United Kingdom of Great Britain and Northern Ireland
| | - Chao Zhang
- Department of Ultrasound, Zhejiang University School of Medicine Second Affiliated Hospital, Hangzhou, People's Republic of China
| | - Kirsten Christensen-Jeffries
- Imaging Sciences and Biomedical Engineering, King's College London School of Medical Education, London, United Kingdom of Great Britain and Northern Ireland
| | - Ge Zhang
- Bioengineering, Imperial College London, London, United Kingdom of Great Britain and Northern Ireland
| | - Sevan Harput
- Division of Electrical and Electronic Engineering, London South Bank University, London, United Kingdom of Great Britain and Northern Ireland
| | - Christopher Dunsby
- Physics, Imperial College London, London, United Kingdom of Great Britain and Northern Ireland
| | - Pintong Huang
- Department of Ultrasound, Zhejiang University School of Medicine Second Affiliated Hospital, Hangzhou, People's Republic of China
| | - Meng-Xing Tang
- Bioengineering, Imperial College London, London, United Kingdom of Great Britain and Northern Ireland
| |
Collapse
|
34
|
Zhang W, Yi H, Cai B, He Y, Huang S, Zhang Y. Feasibility of contrast-enhanced ultrasonography (CEUS) in evaluating renal microvascular perfusion in pediatric patients. BMC Med Imaging 2022; 22:194. [PMID: 36357841 PMCID: PMC9650893 DOI: 10.1186/s12880-022-00925-z] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/25/2022] [Accepted: 11/01/2022] [Indexed: 11/12/2022] Open
Abstract
Background Changes in renal microvascular perfusion are involved in several kidney diseases. Contrast-enhanced ultrasonography (CEUS) quantitative analysis can enable the estimation of renal microvascular perfusion non-invasively. However, to date, few pediatric patients with renal disease have been subjected to CEUS quantitative analysis. This study aimed to explore the feasibility of CEUS in evaluating renal microvascular perfusion in pediatric patients and paving its way to clinical practice. Methods Seventeen pediatric patients with chronic kidney disease (CKD) and five children without kidney disease were consecutively examined using CEUS. Quantitative analysis of CEUS images based on time-intensity curve (TIC) fittings was performed using specialized software. Quantitative parameters of wash-in microvascular blood flow, including A, k, B, and TtoPk, were generated from three regions of interest (ROIs) each in the cortex and medulla of each kidney. Results CEUS was performed in all children successfully and safely without the use of sedatives. All parameters (A, B, k, and TtoPk) demonstrated no statistical differences among the three sampling ROIs in the renal cortex and medulla. All parameters (A, B, k, and TtoPk) showed no statistical differences between the left and right sides of kidneys both in cortices and medullas. Comparing with patients with CKD stage 3–5, both control group and patients with CKD stage 1–2 had significantly higher values of parameter A in the renal cortex (p = 0.025 and p = 0.031, respectively). In control group and patients stage 1–2, the values of parameters k in the renal cortices were significantly higher than that in the renal medullas, while in patients with CKD stage 3–5, parameter k showed no statistically significant differences between the renal cortex and medulla (p = 0.173). Conclusion CEUS is safe and practicable in pediatric patients with chronic kidney disease. Renal microvascular perfusion estimated by CEUS could be a robust approach in the evaluation of pediatric renal diseases. Parameters A and k derived from CEUS quantitative analysis can provide great potential in non-invasive assessment of renal microvascular perfusion impairment in pediatric CKD.
Collapse
|
35
|
Kierski TM, Walmer RW, Tsuruta JK, Yin J, Chérin E, Foster FS, Demore CEM, Newsome IG, Pinton GF, Dayton PA. Acoustic Molecular Imaging Beyond the Diffraction Limit In Vivo. IEEE OPEN JOURNAL OF ULTRASONICS, FERROELECTRICS, AND FREQUENCY CONTROL 2022; 2:237-249. [PMID: 38125957 PMCID: PMC10732349 DOI: 10.1109/ojuffc.2022.3212342] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Indexed: 12/23/2023]
Abstract
Ultrasound molecular imaging (USMI) is a technique used to noninvasively estimate the distribution of molecular markers in vivo by imaging microbubble contrast agents (MCAs) that have been modified to target receptors of interest on the vascular endothelium. USMI is especially relevant for preclinical and clinical cancer research and has been used to predict tumor malignancy and response to treatment. In the last decade, methods that improve the resolution of contrast-enhanced ultrasound by an order of magnitude and allow researchers to noninvasively image individual capillaries have emerged. However, these approaches do not translate directly to molecular imaging. In this work, we demonstrate super-resolution visualization of biomarker expression in vivo using superharmonic ultrasound imaging (SpHI) with dual-frequency transducers, targeted contrast agents, and localization microscopy processing. We validate and optimize the proposed method in vitro using concurrent optical and ultrasound microscopy and a microvessel phantom. With the same technique, we perform a proof-of-concept experiment in vivo in a rat fibrosarcoma model and create maps of biomarker expression co-registered with images of microvasculature. From these images, we measure a resolution of 23 μm, a nearly fivefold improvement in resolution compared to previous diffraction-limited molecular imaging studies.
Collapse
Affiliation(s)
- Thomas M Kierski
- Joint Department of Biomedical Engineering, UNC-Chapel Hill and NC State University, Chapel Hill, NC 27599 USA
| | - Rachel W Walmer
- Joint Department of Biomedical Engineering, UNC-Chapel Hill and NC State University, Chapel Hill, NC 27599 USA
| | - James K Tsuruta
- Joint Department of Biomedical Engineering, UNC-Chapel Hill and NC State University, Chapel Hill, NC 27599 USA
| | - Jianhua Yin
- Sunnybrook Research Institute, Toronto, ON M4N 3M5, Canada
| | | | - F Stuart Foster
- Sunnybrook Research Institute, Toronto, ON M4N 3M5, Canada
- Department of Medical Biophysics, University of Toronto, Toronto, ON M4N 3M5, Canada
| | - Christine E M Demore
- Sunnybrook Research Institute, Toronto, ON M4N 3M5, Canada
- Department of Medical Biophysics, University of Toronto, Toronto, ON M4N 3M5, Canada
| | - Isabel G Newsome
- Joint Department of Biomedical Engineering, UNC-Chapel Hill and NC State University, Chapel Hill, NC 27599 USA
| | - Gianmarco F Pinton
- Joint Department of Biomedical Engineering, UNC-Chapel Hill and NC State University, Chapel Hill, NC 27599 USA
| | - Paul A Dayton
- Joint Department of Biomedical Engineering, UNC-Chapel Hill and NC State University, Chapel Hill, NC 27599 USA
| |
Collapse
|
36
|
Zhu JY, He HL, Lin ZM, Zhao JQ, Jiang XC, Liang ZH, Huang XP, Bao HW, Huang PT, Chen F. Ultrasound-based radiomics analysis for differentiating benign and malignant breast lesions: From static images to CEUS video analysis. Front Oncol 2022; 12:951973. [PMID: 36185229 PMCID: PMC9523748 DOI: 10.3389/fonc.2022.951973] [Citation(s) in RCA: 7] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/24/2022] [Accepted: 08/24/2022] [Indexed: 11/13/2022] Open
Abstract
Background Continuous contrast-enhanced ultrasound (CEUS) video is a challenging direction for radiomics research. We aimed to evaluate machine learning (ML) approaches with radiomics combined with the XGBoost model and a convolutional neural network (CNN) for discriminating between benign and malignant lesions in CEUS videos with a duration of more than 1 min. Methods We gathered breast CEUS videos of 109 benign and 81 malignant tumors from two centers. Radiomics combined with the XGBoost model and a CNN was used to classify the breast lesions on the CEUS videos. The lesions were manually segmented by one radiologist. Radiomics combined with the XGBoost model was conducted with a variety of data sampling methods. The CNN used pretrained 3D residual network (ResNet) models with 18, 34, 50, and 101 layers. The machine interpretations were compared with prospective interpretations by two radiologists. Breast biopsies or pathological examinations were used as the reference standard. Areas under the receiver operating curves (AUCs) were used to compare the diagnostic performance of the models. Results The CNN model achieved the best AUC of 0.84 on the test cohort with the 3D-ResNet-50 model. The radiomics model obtained AUCs between 0.65 and 0.75. Radiologists 1 and 2 had AUCs of 0.75 and 0.70, respectively. Conclusions The 3D-ResNet-50 model was superior to the radiomics combined with the XGBoost model in classifying enhanced lesions as benign or malignant on CEUS videos. The CNN model was superior to the radiologists, and the radiomics model performance was close to the performance of the radiologists.
Collapse
Affiliation(s)
- Jun-Yan Zhu
- Department of Ultrasound, The First Affiliated Hospital of Zhejiang Chinese Medical University, Hangzhou, China
| | - Han-Lu He
- Department of Ultrasound, The First Affiliated Hospital of Zhejiang Chinese Medical University, Hangzhou, China
| | - Zi-Mei Lin
- Ultrasound in Medicine, The Second Affiliated Hospital, Zhejiang University School of Medicine, Hangzhou, China
| | | | - Xiao-Chun Jiang
- Department of Ultrasound, The First Affiliated Hospital of Zhejiang Chinese Medical University, Hangzhou, China
| | - Zhe-Hao Liang
- Department of Ultrasound, The First Affiliated Hospital of Zhejiang Chinese Medical University, Hangzhou, China
| | - Xiao-Ping Huang
- Department of Ultrasound, The First Affiliated Hospital of Zhejiang Chinese Medical University, Hangzhou, China
| | - Hai-Wei Bao
- Department of Ultrasound, The First Affiliated Hospital of Zhejiang Chinese Medical University, Hangzhou, China
| | - Pin-Tong Huang
- Ultrasound in Medicine, The Second Affiliated Hospital, Zhejiang University School of Medicine, Hangzhou, China
| | - Fen Chen
- Department of Ultrasound, The First Affiliated Hospital of Zhejiang Chinese Medical University, Hangzhou, China
| |
Collapse
|
37
|
Friedl S, Jung EM, Bergler T, Tews HC, Banas MC, Banas B, Putz FJ. Factors influencing the time-intensity curve analysis of contrast-enhanced ultrasound in kidney transplanted patients: Toward a standardized contrast-enhanced ultrasound examination. Front Med (Lausanne) 2022; 9:928567. [PMID: 36091698 PMCID: PMC9452686 DOI: 10.3389/fmed.2022.928567] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/25/2022] [Accepted: 07/29/2022] [Indexed: 11/15/2022] Open
Abstract
Background Time-intensity curve analysis (TIC analysis) based on contrast-enhanced ultrasound (CEUS) provides quantifiable information about the microcirculation of different tissues. TIC analysis of kidney transplantations is still a field of research, and standardized study protocols are missing though being mandatory for the interpretation of TIC parameters in the clinical context. The aim of this study was to evaluate the impact of different sizes and forms of regions of interest (ROIs) on the variance of different TIC parameters and the level of interoperator variance between the different ROI methods in kidney transplantations. Methods In 25 renal transplanted patients, 33 CEUS of the transplanted kidney were performed, and TIC analysis with ROIs sized 5 mm2 (ROI5), 10 mm2 (ROI10), and ROIs circumscribing the outlines of anatomical regions (ROI Anat ) were analyzed based on CEUS examination. The TIC analysis was repeated by a second independent operator for ROI5 and ROI Anat . Results Statistical analysis revealed significant differences between TIC parameters of different ROI methods, and overall, the interoperator variance was low. But a greater ROI surface (ROI10) led to higher values of the intensity parameters A and AUC compared with ROI5 (p < 0.05). The difference in the ROI form led to high variation of certain TIC parameters between ROI5 and ROI Anat in the myelon [intraclass correlation coefficient (A, ICC = 0.578 (0.139-0.793); TIC parameter (TTP); and ICC = 0.679 (0.344-0.842) (p < 0.05)]. A mean variation of 1 cm of the depth of ROI5 in the cortex did not show significant differences in the TIC parameters, though there was an impact of depth of ROI Anat on the values of TIC parameters. The interoperator variance in the cortex was low and equal for ROI5 and ROI Anat , but increased in the myelon, especially for ROI Anat . Furthermore, the analysis revealed a strong correlation between the parameter AUC and the time interval applied for the TIC analysis in the cortex and myelon (r = 0.710, 0.674, p < 0.000). Conclusion Our findings suggest the application of multiple ROIs of 5 mm2 in the cortex and medulla to perform TIC analysis of kidney transplants. For clinical interpretation of AUC, a standardized time interval for TIC analysis should be developed. After the standardization of the TIC analysis, the clinical predictive value could be investigated in further studies.
Collapse
Affiliation(s)
- Sarah Friedl
- Department of Nephrology, University of Regensburg, Regensburg, Germany
| | - Ernst Michael Jung
- Department of Radiology, Interdisciplinary Ultrasound, University of Regensburg, Regensburg, Germany
| | - Tobias Bergler
- Department of Nephrology, University of Regensburg, Regensburg, Germany
| | - Hauke C. Tews
- Department of Internal Medicine I, Gastroenterology, Hepatology, Endocrinology, Rheumatology and Infectious Diseases, University Hospital, Regensburg, Germany
| | - Miriam C. Banas
- Department of Nephrology, University of Regensburg, Regensburg, Germany
| | - Bernhard Banas
- Department of Nephrology, University of Regensburg, Regensburg, Germany
| | - Franz Josef Putz
- Department of Nephrology, University of Regensburg, Regensburg, Germany
| |
Collapse
|
38
|
Wahyulaksana G, Wei L, Schoormans J, Voorneveld J, van der Steen AFW, de Jong N, Vos HJ. Independent Component Analysis Filter for Small Vessel Contrast Imaging During Fast Tissue Motion. IEEE TRANSACTIONS ON ULTRASONICS, FERROELECTRICS, AND FREQUENCY CONTROL 2022; 69:2282-2292. [PMID: 35594222 DOI: 10.1109/tuffc.2022.3176742] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/15/2023]
Abstract
Suppressing tissue clutter is an essential step in blood flow estimation and visualization, even when using ultrasound contrast agents. Blind source separation (BSS)-based clutter filter for high-framerate ultrasound imaging has been reported to perform better in tissue clutter suppression than the conventional frequency-based wall filter and nonlinear contrast pulsing schemes. The most notable BSS technique, singular value decomposition (SVD) has shown compelling results in cases of slow tissue motion. However, its performance degrades when the tissue motion is faster than the blood flow speed, conditions that are likely to occur when imaging the small vessels, such as in the myocardium. Independent component analysis (ICA) is another BSS technique that has been implemented as a clutter filter in the spatiotemporal domain. Instead, we propose to implement ICA in the spatial domain where motion should have less impact. In this work, we propose a clutter filter with the combination of SVD and ICA to improve the contrast-to-background ratio (CBR) in cases where tissue velocity is significantly faster than the flow speed. In an in vitro study, the range of fast tissue motion velocity was 5-25 mm/s and the range of flow speed was 1-12 mm/s. Our results show that the combination of ICA and SVD yields 7-10 dB higher CBR than SVD alone, especially in the tissue high-velocity range. The improvement is crucial for cardiac imaging where relatively fast myocardial motions are expected.
Collapse
|
39
|
He L, Li Z, Zhang Q, Chen Y, Gao Y, Chen T, Wang N, Jiang L, Fan Y. Evaluation of renal microperfusion in hyperuricemic nephropathy by Contrast-Enhanced Ultrasound imaging. Dis Model Mech 2022; 15:276106. [PMID: 35645166 PMCID: PMC9346517 DOI: 10.1242/dmm.049382] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/05/2021] [Accepted: 05/24/2022] [Indexed: 11/24/2022] Open
Abstract
Diagnostic tools for the early detection of renal injury caused by hyperuricemia are still lacking. Here, we investigated whether contrast-enhanced ultrasound (CEUS) could be used as a diagnostic tool for hyperuricemic nephropathy (HN). In the HN rat model, CEUS detected a significant decline in renal cortical perfusion compared with that in control rats. Peak intensity (PI) values correlated significantly with serum KIM-1 levels and fibrosis scores in HN rats. An early decline in PI values was also observed in chronic kidney disease (CKD) stage 1 patients with HN compared with the controls (61.1±4.52 dB versus 65.80±7.10 dB) and correlated with renal function in the patients with HN. In contrast, an increase in time to reach PI values was detected in HN patients with stage 1 CKD (15.14±1.75 s versus 14.52±4.75 s) and was more pronounced in CKD stage 4 patients (67.32±3.29 s). CEUS was able to detect abnormal renal perfusion in early CKD with HN, which correlated with renal function decline, suggesting that CEUS could be used as a noninvasive tool for assessing renal function in patients with HN.
Collapse
Affiliation(s)
- Li He
- Department of Nephrology, Shanghai Jiao Tong University Affiliated Sixth People's Hospital, Shanghai 200233, China
| | - Ze Li
- Department of Nephrology, Shanghai Jiao Tong University Affiliated Sixth People's Hospital, Shanghai 200233, China
| | - Qunzi Zhang
- Department of Nephrology, Shanghai Jiao Tong University Affiliated Sixth People's Hospital, Shanghai 200233, China
| | - Yini Chen
- Ultrasonic department, Shanghai Jiao Tong University Affiliated Sixth People's Hospital, Shanghai 200233, China
| | - Yihui Gao
- Ultrasonic department, Shanghai Jiao Tong University Affiliated Sixth People's Hospital, Shanghai 200233, China
| | - Teng Chen
- Department of Nephrology, Shanghai Jiao Tong University Affiliated Sixth People's Hospital, Shanghai 200233, China
| | - Niansong Wang
- Department of Nephrology, Shanghai Jiao Tong University Affiliated Sixth People's Hospital, Shanghai 200233, China
| | - Lixin Jiang
- Ultrasonic department, Renji Hospital, School of Medicine, Shanghai Jiao Tong University, Shanghai 200127, China
| | - Ying Fan
- Department of Nephrology, Shanghai Jiao Tong University Affiliated Sixth People's Hospital, Shanghai 200233, China
| |
Collapse
|
40
|
Yan Y, Tang L, Huang H, Yu Q, Xu H, Chen Y, Chen M, Zhang Q. Four-quadrant fast compressive tracking of breast ultrasound videos for computer-aided response evaluation of neoadjuvant chemotherapy in mice. COMPUTER METHODS AND PROGRAMS IN BIOMEDICINE 2022; 217:106698. [PMID: 35217304 DOI: 10.1016/j.cmpb.2022.106698] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 05/07/2021] [Revised: 01/26/2022] [Accepted: 02/08/2022] [Indexed: 06/14/2023]
Abstract
BACKGROUND AND OBJECTIVE Neoadjuvant chemotherapy (NAC) is a valuable treatment approach for locally advanced breast cancer. Contrast-enhanced ultrasound (CEUS) potentially enables the assessment of therapeutic response to NAC. In order to evaluate the response accurately, quantitatively and objectively, a method that can effectively compensate motions of breast cancer in CEUS videos is urgently needed. METHODS We proposed the four-quadrant fast compressive tracking (FQFCT) approach to automatically perform CEUS video tracking and compensation for mice undergoing NAC. The FQFCT divided a tracking window into four smaller windows at four quadrants of a breast lesion and formulated the tracking at each quadrant as a binary classification task. After the FQFCT of breast cancer videos, the quantitative features of CEUS including the mean transit time (MTT) were computed. All mice showed a pathological response to NAC. The features between pre- (day 1) and post-treatment (day 3 and day 5) in these responders were statistically compared. RESULTS When we tracked the CEUS videos of mice with the FQFCT, the average tracking error of FQFCT was 0.65 mm, reduced by 46.72% compared with the classic fast compressive tracking method (1.22 mm). After compensation with the FQFCT, the MTT on day 5 of the NAC was significantly different from the MTT before NAC (day 1) (p = 0.013). CONCLUSIONS The FQFCT improves the accuracy of CEUS video tracking and contributes to the computer-aided response evaluation of NAC for breast cancer in mice.
Collapse
Affiliation(s)
- Yifei Yan
- The SMART (Smart Medicine and AI-Based Radiology Technology) Lab, Shanghai Institute for Advanced Communication and Data Science, Shanghai University, Shanghai, China; School of Communication and Information Engineering, Shanghai University, Shanghai 200444, China
| | - Lei Tang
- Department of Ultrasound, Tongren Hospital, School of Medicine, Shanghai Jiaotong University, Shanghai 200050, China
| | - Haibo Huang
- The SMART (Smart Medicine and AI-Based Radiology Technology) Lab, Shanghai Institute for Advanced Communication and Data Science, Shanghai University, Shanghai, China; School of Communication and Information Engineering, Shanghai University, Shanghai 200444, China
| | - Qihui Yu
- The SMART (Smart Medicine and AI-Based Radiology Technology) Lab, Shanghai Institute for Advanced Communication and Data Science, Shanghai University, Shanghai, China; School of Communication and Information Engineering, Shanghai University, Shanghai 200444, China
| | - Haohao Xu
- The SMART (Smart Medicine and AI-Based Radiology Technology) Lab, Shanghai Institute for Advanced Communication and Data Science, Shanghai University, Shanghai, China; School of Communication and Information Engineering, Shanghai University, Shanghai 200444, China
| | - Ying Chen
- The SMART (Smart Medicine and AI-Based Radiology Technology) Lab, Shanghai Institute for Advanced Communication and Data Science, Shanghai University, Shanghai, China; School of Communication and Information Engineering, Shanghai University, Shanghai 200444, China
| | - Man Chen
- Department of Ultrasound, Tongren Hospital, School of Medicine, Shanghai Jiaotong University, Shanghai 200050, China.
| | - Qi Zhang
- The SMART (Smart Medicine and AI-Based Radiology Technology) Lab, Shanghai Institute for Advanced Communication and Data Science, Shanghai University, Shanghai, China; School of Communication and Information Engineering, Shanghai University, Shanghai 200444, China.
| |
Collapse
|
41
|
Yi HM, Lowerison MR, Song PF, Zhang W. A Review of Clinical Applications for Super-resolution Ultrasound Localization Microscopy. Curr Med Sci 2022; 42:1-16. [PMID: 35167000 DOI: 10.1007/s11596-021-2459-2] [Citation(s) in RCA: 17] [Impact Index Per Article: 5.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/13/2020] [Accepted: 03/11/2021] [Indexed: 12/21/2022]
Abstract
Microvascular structure and hemodynamics are important indicators for the diagnosis and assessment of many diseases and pathologies. The structural and functional imaging of tissue microvasculature in vivo is a clinically significant objective for the development of many imaging modalities. Contrast-enhanced ultrasound (CEUS) is a popular clinical tool for characterizing tissue microvasculature, due to the moderate cost, wide accessibility, and absence of ionizing radiation of ultrasound. However, in practice, it remains challenging to demonstrate microvasculature using CEUS, due to the resolution limit of conventional ultrasound imaging. In addition, the quantification of tissue perfusion by CEUS remains hindered by high operator-dependency and poor reproducibility. Inspired by super-resolution optical microscopy, super-resolution ultrasound localization microscopy (ULM) was recently developed. ULM uses the same ultrasound contrast agent (i.e. microbubbles) in CEUS. However, different from CEUS, ULM uses the location of the microbubbles to construct images, instead of using the backscattering intensity of microbubbles. Hence, ULM overcomes the classic compromise between imaging resolution and penetration, allowing for the visualization of capillary-scale microvasculature deep within tissues. To date, many in vivo ULM results have been reported, including both animal (kidney, brain, spinal cord, xenografted tumor, and ear) and human studies (prostate, tibialis anterior muscle, and breast cancer tumors). Furthermore, a variety of useful biomarkers have been derived from using ULM for different preclinical and clinical applications. Due to the high spatial resolution and accurate blood flow speed estimation (approximately 1 mm/s to several cm/s), ULM presents as an enticing alternative to CEUS for characterizing tissue microvasculature in vivo. This review summarizes the principles and present applications of CEUS and ULM, and discusses areas where ULM can potentially provide a better alternative to CEUS in clinical practice and areas where ULM may not be a better alternative. The objective of the study is to provide clinicians with an up-to-date review of ULM technology, and a practical guide for implementing ULM in clinical research and practice.
Collapse
Affiliation(s)
- Hui-Ming Yi
- Department of Medical Ultrasound, Tongji Hospital, Tongji Medical College, Huazhong University of Science and Technology, Wuhan, 430030, China.,Beckman Institute for Advanced Science and Technology, University of Illinois at Urbana-Champaign, Urbana, 61801, USA.,Department of Electrical and Computer Engineering, University of Illinois at Urbana-Champaign, Urbana, 61801, USA
| | - Matthew R Lowerison
- Beckman Institute for Advanced Science and Technology, University of Illinois at Urbana-Champaign, Urbana, 61801, USA.,Department of Electrical and Computer Engineering, University of Illinois at Urbana-Champaign, Urbana, 61801, USA
| | - Peng-Fei Song
- Beckman Institute for Advanced Science and Technology, University of Illinois at Urbana-Champaign, Urbana, 61801, USA.,Department of Electrical and Computer Engineering, University of Illinois at Urbana-Champaign, Urbana, 61801, USA
| | - Wei Zhang
- Department of Medical Ultrasound, Tongji Hospital, Tongji Medical College, Huazhong University of Science and Technology, Wuhan, 430030, China. .,Beckman Institute for Advanced Science and Technology, University of Illinois at Urbana-Champaign, Urbana, 61801, USA. .,Department of Electrical and Computer Engineering, University of Illinois at Urbana-Champaign, Urbana, 61801, USA.
| |
Collapse
|
42
|
Sævik F, Gilja OH, Nylund K. Gastrointestinal Ultrasound Can Predict Endoscopic Activity in Crohn's Disease. ULTRASCHALL IN DER MEDIZIN (STUTTGART, GERMANY : 1980) 2022; 43:82-89. [PMID: 32330994 DOI: 10.1055/a-1149-9092] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/11/2023]
Abstract
PURPOSE To explore the ability of gastrointestinal ultrasound (GIUS) to separate patients in endoscopic remission from patients with active disease in a heterogeneous hospital cohort with Crohn's disease (CD). MATERIALS AND METHODS 145 CD patients scheduled for ileocolonoscopy were prospectively included. The endoscopic disease activity was quantified using the Simple Endoscopic Score for Crohn's disease (SES-CD), and mucosal healing was strictly defined as SES-CD = 0. Ultrasound remission was defined as wall thickness < 3 mm (< 4 mm in the rectum). Additionally, SES-CD was compared to color Doppler, Harvey Bradshaw's index (HBI), C-reactive protein (CRP) and calprotectin. 23 patients were examined by two investigators for interobserver assessment. RESULTS 102 had active disease and 43 patients were in remission. GIUS yielded a sensitivity of 92.2 % and a specificity of 86 % for wall thickness and a sensitivity of 66.7 % and a specificity of 97.7 % for color Doppler. The sensitivity and specificity were 34.3 % and 88.4 %, respectively, for HBI, 35.7 % and 82.9 %, respectively, for CRP and 55.9 % and 82.1 %, respectively, for calprotectin. The interobserver analysis revealed excellent agreement for wall thickness (k = 0.90) and color Doppler (k = 0.91) measurements. CONCLUSION GIUS has a high sensitivity for detecting endoscopic activity. Accordingly, bowel ultrasound has the potential to reduce the number of routine ileocolonoscopies in patients with CD.
Collapse
Affiliation(s)
- Fredrik Sævik
- National Centre for Ultrasound in Gastroenterology, Haukeland University Hospital, Bergen, Norway
- Department of Clinical Medicine, University of Bergen, Norway
| | - Odd Helge Gilja
- National Centre for Ultrasound in Gastroenterology, Haukeland University Hospital, Bergen, Norway
- Department of Clinical Medicine, University of Bergen, Norway
| | - Kim Nylund
- National Centre for Ultrasound in Gastroenterology, Haukeland University Hospital, Bergen, Norway
- Department of Clinical Medicine, University of Bergen, Norway
| |
Collapse
|
43
|
Lowerison MR, Sekaran NVC, Zhang W, Dong Z, Chen X, Llano DA, Song P. Aging-related cerebral microvascular changes visualized using ultrasound localization microscopy in the living mouse. Sci Rep 2022; 12:619. [PMID: 35022482 PMCID: PMC8755738 DOI: 10.1038/s41598-021-04712-8] [Citation(s) in RCA: 59] [Impact Index Per Article: 19.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/19/2021] [Accepted: 12/14/2021] [Indexed: 01/09/2023] Open
Abstract
Aging-related cognitive decline is an emerging health crisis; however, no established unifying mechanism has been identified for the cognitive impairments seen in an aging population. A vascular hypothesis of cognitive decline has been proposed but is difficult to test given the requirement of high-fidelity microvascular imaging resolution with a broad and deep brain imaging field of view, which is restricted by the fundamental trade-off of imaging penetration depth and resolution. Super-resolution ultrasound localization microscopy (ULM) offers a potential solution by exploiting circulating microbubbles to achieve a vascular resolution approaching the capillary scale without sacrificing imaging depth. In this report, we apply ULM imaging to a mouse model of aging and quantify differences in cerebral vascularity, blood velocity, and vessel tortuosity across several brain regions. We found significant decreases in blood velocity, and significant increases in vascular tortuosity, across all brain regions in the aged cohort, and significant decreases in blood volume in the cerebral cortex. These data provide the first-ever ULM measurements of subcortical microvascular dynamics in vivo within the context of the aging brain and reveal that aging has a major impact on these measurements.
Collapse
Affiliation(s)
- Matthew R Lowerison
- Beckman Institute for Advanced Science and Technology, University of Illinois at Urbana-Champaign, Urbana, IL, USA
- Department of Electrical and Computer Engineering, Beckman Institute for Advanced Science and Technology, University of Illinois at Urbana-Champaign, 405 N. Mathews Ave, Urbana, IL, 61801, USA
| | - Nathiya Vaithiyalingam Chandra Sekaran
- Beckman Institute for Advanced Science and Technology, University of Illinois at Urbana-Champaign, Urbana, IL, USA
- Department of Molecular and Integrative Physiology, Beckman Institute for Advanced Science and Technology, University of Illinois at Urbana-Champaign, 405 N. Mathews Ave, Urbana, IL, 61801, USA
| | - Wei Zhang
- Beckman Institute for Advanced Science and Technology, University of Illinois at Urbana-Champaign, Urbana, IL, USA
- Department of Electrical and Computer Engineering, Beckman Institute for Advanced Science and Technology, University of Illinois at Urbana-Champaign, 405 N. Mathews Ave, Urbana, IL, 61801, USA
- Department of Medical Ultrasound, Tongji Hospital, Tongji Medical College, Wuhan City, Hubei Province, China
| | - Zhijie Dong
- Beckman Institute for Advanced Science and Technology, University of Illinois at Urbana-Champaign, Urbana, IL, USA
- Department of Electrical and Computer Engineering, Beckman Institute for Advanced Science and Technology, University of Illinois at Urbana-Champaign, 405 N. Mathews Ave, Urbana, IL, 61801, USA
| | - Xi Chen
- Beckman Institute for Advanced Science and Technology, University of Illinois at Urbana-Champaign, Urbana, IL, USA
- Department of Electrical and Computer Engineering, Beckman Institute for Advanced Science and Technology, University of Illinois at Urbana-Champaign, 405 N. Mathews Ave, Urbana, IL, 61801, USA
| | - Daniel A Llano
- Beckman Institute for Advanced Science and Technology, University of Illinois at Urbana-Champaign, Urbana, IL, USA.
- Department of Molecular and Integrative Physiology, Beckman Institute for Advanced Science and Technology, University of Illinois at Urbana-Champaign, 405 N. Mathews Ave, Urbana, IL, 61801, USA.
| | - Pengfei Song
- Beckman Institute for Advanced Science and Technology, University of Illinois at Urbana-Champaign, Urbana, IL, USA.
- Department of Electrical and Computer Engineering, Beckman Institute for Advanced Science and Technology, University of Illinois at Urbana-Champaign, 405 N. Mathews Ave, Urbana, IL, 61801, USA.
| |
Collapse
|
44
|
Spediacci C, Manfredi M, Sala G, Liuti T, Israeliantz N, Zani DD, Di Giancamillo M, Longo M. Fall time may be a reliable discriminator between neoplastic and non-neoplastic urinary bladder lesions in dogs undergoing contrast-enhanced ultrasound: a pilot study. Vet Radiol Ultrasound 2022; 63:609-619. [PMID: 35679465 PMCID: PMC9796640 DOI: 10.1111/vru.13105] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/24/2021] [Revised: 03/08/2022] [Accepted: 03/10/2022] [Indexed: 01/01/2023] Open
Abstract
Contrast-enhanced ultrasound (CEUS) can provide quantitative information on enhancement patterns and perfusion of lesions, based on time-intensity curves (TICs). No published studies have compared CEUS parameters in neoplastic and non-neoplastic urinary bladder lesions in dogs. The aim of the current prospective, pilot study was to quantitatively characterize the CEUS pattern of neoplastic and non-neoplastic urinary bladder lesions in dogs, assessing the influence of contrast arrival time (CAT) on the final appearance of the curves. Fourteen dogs with cyto-histopathological diagnoses were included (seven malignant and seven inflammatory lesions). B-mode ultrasound was performed followed by CEUS examination after an intravenous bolus injection of 0.04 mL/kg of contrast medium, and TICs were elaborated by dedicated software. Receiver operating characteristic curves (ROC) for each TIC parameter were obtained. Neoplastic lesions had subjectively shorter rise time (RT), time to peak (TTP) and fall time (FT) than inflammatory lesions. Based on ROC curve analyses, fall time ≥ 10.49 s was the most reliable parameter for diagnosing non-neoplastic disease in this small sample of dogs (area under the curve [AUC] 0.75, sensitivity 83.33%, specificity 66.67%). No difference was found between ROCs calculated for each parameter of TICs by adding or removing CAT. Results of the current study provide background for future, larger scale studies evaluating use of a CEUS FT threshold of 10.49 s as a possible discriminator for urinary bladder neoplastic lesions in dogs.
Collapse
Affiliation(s)
- Carlotta Spediacci
- Departement of Veterinary Medicine and Animal Science (DIVAS)University of Milan, Street of University n. 6Lodi (LO)26900Italy
| | - Martina Manfredi
- Departement of Veterinary Medicine and Animal Science (DIVAS)University of Milan, Street of University n. 6Lodi (LO)26900Italy
| | - Giulia Sala
- Departement of Veterinary Medicine and Animal Science (DIVAS)University of Milan, Street of University n. 6Lodi (LO)26900Italy
| | - Tiziana Liuti
- Royal Dick School of Veterinary StudiesUniversity of EdinburghEdinburghScotlandUK
| | - Nicolas Israeliantz
- Royal Dick School of Veterinary StudiesUniversity of EdinburghEdinburghScotlandUK
| | - Davide Danilo Zani
- Departement of Veterinary Medicine and Animal Science (DIVAS)University of Milan, Street of University n. 6Lodi (LO)26900Italy
| | - Mauro Di Giancamillo
- Departement of Veterinary Medicine and Animal Science (DIVAS)University of Milan, Street of University n. 6Lodi (LO)26900Italy
| | - Maurizio Longo
- Departement of Veterinary Medicine and Animal Science (DIVAS)University of Milan, Street of University n. 6Lodi (LO)26900Italy
| |
Collapse
|
45
|
Hwang M, Back SJ, Didier RA, Lorenz N, Morgan TA, Poznick L, Steffgen L, Sridharan A. Pediatric contrast-enhanced ultrasound: optimization of techniques and dosing. Pediatr Radiol 2021; 51:2147-2160. [PMID: 32955599 DOI: 10.1007/s00247-020-04812-z] [Citation(s) in RCA: 14] [Impact Index Per Article: 3.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 06/24/2020] [Revised: 07/08/2020] [Accepted: 08/10/2020] [Indexed: 12/11/2022]
Abstract
When performing contrast-enhanced ultrasound (CEUS), ultrasound (US) scanner settings, examination technique, and contrast agent dose and administration must be optimized to ensure that high-quality, diagnostic and reproducible images are acquired for qualitative and quantitative interpretations. When carrying out CEUS in children, examination settings should be tailored to their body size and specific indications, similar to B-mode US. This review article details the basic background knowledge that is needed to perform CEUS optimally in children, including considerations related to US scanner settings and US contrast agent dose selection and administration techniques.
Collapse
Affiliation(s)
- Misun Hwang
- Department of Radiology, Children's Hospital of Philadelphia, 3401 Civic Center Blvd., Philadelphia, PA, 19104, USA. .,Perelman School of Medicine, University of Pennsylvania, Philadelphia, PA, USA.
| | - Susan J Back
- Department of Radiology, Children's Hospital of Philadelphia, 3401 Civic Center Blvd., Philadelphia, PA, 19104, USA.,Perelman School of Medicine, University of Pennsylvania, Philadelphia, PA, USA
| | - Ryne A Didier
- Department of Radiology, Children's Hospital of Philadelphia, 3401 Civic Center Blvd., Philadelphia, PA, 19104, USA.,Perelman School of Medicine, University of Pennsylvania, Philadelphia, PA, USA
| | - Norbert Lorenz
- Children's Hospital, Dresden Municipal Hospital, Teaching-Hospital of Technical University, Dresden, Germany
| | - Trudy A Morgan
- Department of Radiology, Children's Hospital of Philadelphia, 3401 Civic Center Blvd., Philadelphia, PA, 19104, USA
| | - Laura Poznick
- Department of Radiology, Children's Hospital of Philadelphia, 3401 Civic Center Blvd., Philadelphia, PA, 19104, USA
| | - Ludwig Steffgen
- Trainings-Zentrum Ultraschall-Diagnostik LS GmbH, Mainleus, Germany
| | - Anush Sridharan
- Department of Radiology, Children's Hospital of Philadelphia, 3401 Civic Center Blvd., Philadelphia, PA, 19104, USA
| |
Collapse
|
46
|
Hwang M, Barnewolt CE, Jüngert J, Prada F, Sridharan A, Didier RA. Contrast-enhanced ultrasound of the pediatric brain. Pediatr Radiol 2021; 51:2270-2283. [PMID: 33599780 PMCID: PMC11458139 DOI: 10.1007/s00247-021-04974-4] [Citation(s) in RCA: 23] [Impact Index Per Article: 5.8] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 10/12/2020] [Revised: 11/10/2020] [Accepted: 01/14/2021] [Indexed: 12/16/2022]
Abstract
Brain contrast-enhanced ultrasound (CEUS) is an emerging application that can complement gray-scale US and yield additional insights into cerebral flow dynamics. CEUS uses intravenous injection of ultrasound contrast agents (UCAs) to highlight tissue perfusion and thus more clearly delineate cerebral pathologies including stroke, hypoxic-ischemic injury and focal lesions such as tumors and vascular malformations. It can be applied not only in infants with open fontanelles but also in older children and adults via a transtemporal window or surgically created acoustic window. Advancements in CEUS technology and post-processing methods for quantitative analysis of UCA kinetics further elucidate cerebral microcirculation. In this review article we discuss the CEUS examination protocol for brain imaging in children, current clinical applications and future directions for research and clinical uses of brain CEUS.
Collapse
Affiliation(s)
- Misun Hwang
- Department of Radiology, Children's Hospital of Philadelphia, 3401 Civic Center Blvd., Philadelphia, PA, 19104, USA.
- Perelman School of Medicine, University of Pennsylvania, Philadelphia, PA, USA.
| | - Carol E Barnewolt
- Department of Radiology, Boston Children's Hospital, Harvard University, Boston, MA, USA
| | - Jörg Jüngert
- Department of Pediatrics, Friedrich-Alexander University Erlangen - Nürnberg, Erlangen, Germany
| | - Francesco Prada
- Acoustic Neuroimaging and Therapy Laboratory, Fondazione IRCCS Istituto Neurologico Carlo Besta, Milan, Italy
- Department of Neurological Surgery, University of Virginia School of Medicine, Charlottesville, VA, USA
- Focused Ultrasound Foundation, Charlottesville, VA, USA
| | - Anush Sridharan
- Department of Radiology, Children's Hospital of Philadelphia, 3401 Civic Center Blvd., Philadelphia, PA, 19104, USA
| | - Ryne A Didier
- Department of Radiology, Children's Hospital of Philadelphia, 3401 Civic Center Blvd., Philadelphia, PA, 19104, USA
- Perelman School of Medicine, University of Pennsylvania, Philadelphia, PA, USA
| |
Collapse
|
47
|
Nielsen MB, Søgaard SB, Bech Andersen S, Skjoldbye B, Hansen KL, Rafaelsen S, Nørgaard N, Carlsen JF. Highlights of the development in ultrasound during the last 70 years: A historical review. Acta Radiol 2021; 62:1499-1514. [PMID: 34791887 DOI: 10.1177/02841851211050859] [Citation(s) in RCA: 14] [Impact Index Per Article: 3.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/15/2022]
Abstract
This review looks at highlights of the development in ultrasound, ranging from interventional ultrasound and Doppler to the newest techniques like contrast-enhanced ultrasound and elastography, and gives reference to some of the valuable articles in Acta Radiologica. Ultrasound equipment is now available in any size and for any purpose, ranging from handheld devices to high-end devices, and the scientific societies include ultrasound professionals of all disciplines publishing guidelines and recommendations. Interventional ultrasound is expanding the field of use of ultrasound-guided interventions into nearly all specialties of medicine, from ultrasound guidance in minimally invasive robotic procedures to simple ultrasound-guided punctures performed by general practitioners. Each medical specialty is urged to define minimum requirements for equipment, education, training, and maintenance of skills, also for medical students. The clinical application of contrast-enhanced ultrasound and elastography is a topic often seen in current research settings.
Collapse
Affiliation(s)
- Michael Bachmann Nielsen
- Department of Radiology, Rigshospitalet, Copenhagen, Denmark
- Faculty of Health and Medical Sciences, University of Copenhagen, Copenhagen, Denmark
| | - Stinne Byrholdt Søgaard
- Department of Radiology, Rigshospitalet, Copenhagen, Denmark
- Faculty of Health and Medical Sciences, University of Copenhagen, Copenhagen, Denmark
| | - Sofie Bech Andersen
- Department of Radiology, Rigshospitalet, Copenhagen, Denmark
- Faculty of Health and Medical Sciences, University of Copenhagen, Copenhagen, Denmark
| | - Bjørn Skjoldbye
- Department of Radiology, Aleris-Hamlet Hospitals, Copenhagen Denmark
| | - Kristoffer Lindskov Hansen
- Department of Radiology, Rigshospitalet, Copenhagen, Denmark
- Faculty of Health and Medical Sciences, University of Copenhagen, Copenhagen, Denmark
| | - Søren Rafaelsen
- Department of Radiology, University Hospital of Southern Denmark, Vejle, Denmark
- Faculty of Health Sciences, Institute of Regional Health Research, University of Southern Denmark, Odense, Denmark
| | - Nis Nørgaard
- Department of Urology, Herlev Gentofte Hospital, Copenhagen, Denmark
| | - Jonathan F. Carlsen
- Department of Radiology, Rigshospitalet, Copenhagen, Denmark
- Faculty of Health and Medical Sciences, University of Copenhagen, Copenhagen, Denmark
| |
Collapse
|
48
|
Yin J, Zhang J, Zhu Y, Dong F, An J, Wang D, Li N, Luo Y, Wang Y, Wang X, Zhang J. Ultrasound microvasculature imaging with entropy-based radiality super-resolution (ERSR). Phys Med Biol 2021; 66. [PMID: 34592723 DOI: 10.1088/1361-6560/ac2bb3] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/12/2021] [Accepted: 09/30/2021] [Indexed: 11/12/2022]
Abstract
Objective:Microvasculature is highly relevant to the occurrence and development of pathologies such as cancer and diabetes. Ultrasound localization microscopy (ULM) has bypassed the diffraction limit and demonstrated its great potential to provide new imaging modality and establish new diagnostic criteria in clinical application. However, sparse microbubble distribution can be a significant bottleneck for improving temporal resolution, even for further clinical translation. Other important challenges for ULM to tackle in clinic also include high microbubble concentration and low frame rate.Approach:As part of the efforts to facilitate clinical translation, this paper focused on the low frame rate and the high microbubble distribution issue and proposed a new super-resolution imaging strategy called entropy-based radiality super-resolution (ERSR). The feasibility of ERSR is validated with simulations, phantom experiment and contrast-enhanced ultrasound scan of rabbit sciatic nerve with clinical accessible ultrasound system.Main results:ERSR can achieve 10 times improvement in spatial resolution compared to conventional ultrasound imaging, higher temporal resolution (∼10 times higher) and contrast-to-noise ratio under high-density microbubbles, compared with ULM under low-density microbubbles.Significance:We conclude ERSR could be a valuable imaging tool with high spatio-temporal resolution for clinical diagnosis and assessment of diseases potentially.
Collapse
Affiliation(s)
- Jingyi Yin
- Academy for Advanced Interdisciplinary Studies, Peking University, Beijing, People's Republic of China
| | - Jiabin Zhang
- Institute of Molecular Medicine, Peking University, Beijing, People's Republic of China
| | - Yaqiong Zhu
- Department of Ultrasound, First Medical Centre, Chinese PLA General Hospital, Beijing, People's Republic of China
| | - Feihong Dong
- Academy for Advanced Interdisciplinary Studies, Peking University, Beijing, People's Republic of China.,Institute of Molecular Medicine, Peking University, Beijing, People's Republic of China
| | - Jian An
- Academy for Advanced Interdisciplinary Studies, Peking University, Beijing, People's Republic of China
| | - Di Wang
- Academy for Advanced Interdisciplinary Studies, Peking University, Beijing, People's Republic of China
| | - Nan Li
- Department of Ultrasound, First Medical Centre, Chinese PLA General Hospital, Beijing, People's Republic of China
| | - Yukun Luo
- Department of Ultrasound, First Medical Centre, Chinese PLA General Hospital, Beijing, People's Republic of China
| | - Yuexiang Wang
- Department of Ultrasound, First Medical Centre, Chinese PLA General Hospital, Beijing, People's Republic of China
| | - Xiaoying Wang
- Department of Radiology, Peking University First Hospital, Beijing, People's Republic of China
| | - Jue Zhang
- Academy for Advanced Interdisciplinary Studies, Peking University, Beijing, People's Republic of China.,College of Engineering, Peking University, Beijing, People's Republic of China
| |
Collapse
|
49
|
Gümmer J, Schenke S, Denner F. Modelling Lipid-Coated Microbubbles in Focused Ultrasound Applications at Subresonance Frequencies. ULTRASOUND IN MEDICINE & BIOLOGY 2021; 47:2958-2979. [PMID: 34344560 DOI: 10.1016/j.ultrasmedbio.2021.06.012] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 10/28/2020] [Revised: 06/15/2021] [Accepted: 06/20/2021] [Indexed: 06/13/2023]
Abstract
We present a computational study of the behaviour of a lipid-coated SonoVue microbubble with initial radius 1 µm ≤ R0 ≤ 2 µm, excited at frequencies (200-1500 kHz) significantly below the linear resonance frequency and pressure amplitudes of up to 1500 kPa-an excitation regime used in many applications of focused ultrasound. The bubble dynamics are simulated using the Rayleigh-Plesset equation and the Gilmore equation, in conjunction with the Marmottant model for the lipid monolayer coating. Also, a new continuously differentiable variant of the Marmottant model is introduced. Below the onset of inertial cavitation, a linear regime is identified in which the maximum pressure at the bubble wall is linearly proportional to the excitation pressure amplitude and the mechanical index. This linear regime is bounded by the Blake pressure, and, in line with recent in vitro experiments, the onset of inertial cavitation is found to occur at an excitation pressure amplitude of approximately 130-190 kPa, depending on the initial bubble size. In the nonlinear regime the maximum pressure at the bubble wall is found to be readily predicted by the maximum bubble radius, and both the Rayleigh-Plesset and Gilmore equations are shown to predict the onset of sub- and ultraharmonic frequencies of the acoustic emissions compared with in vitro experiments. Neither the surface dilational viscosity of the lipid monolayer nor the compressibility of the liquid has a discernible influence on the quantities studied, but accounting for the lipid coating is critical for accurate prediction of the bubble behaviour. The Gilmore equation is shown to be valid for the bubbles and excitation regime considered, and the Rayleigh-Plesset equation also provides accurate qualitative predictions, even though it is outside its range of validity for many of the cases considered.
Collapse
Affiliation(s)
- Jonas Gümmer
- Chair of Mechanical Process Engineering, Otto-von-Guericke-Universität Magdeburg, Magdeburg, Germany
| | - Sören Schenke
- Chair of Mechanical Process Engineering, Otto-von-Guericke-Universität Magdeburg, Magdeburg, Germany
| | - Fabian Denner
- Chair of Mechanical Process Engineering, Otto-von-Guericke-Universität Magdeburg, Magdeburg, Germany.
| |
Collapse
|
50
|
Delaney LJ, Tantawi M, Wessner CE, Machado P, Forsberg F, Lyshchik A, O'Kane P, Liu JB, Civan J, Tan A, Anton K, Shaw CM, Eisenbrey JR. Predicting Long-Term Hepatocellular Carcinoma Response to Transarterial Radioembolization Using Contrast-Enhanced Ultrasound: Initial Experiences. ULTRASOUND IN MEDICINE & BIOLOGY 2021; 47:2523-2531. [PMID: 34130880 PMCID: PMC8355136 DOI: 10.1016/j.ultrasmedbio.2021.05.006] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 10/21/2020] [Revised: 02/26/2021] [Accepted: 05/06/2021] [Indexed: 05/12/2023]
Abstract
Conventional cross-sectional imaging done shortly after radioembolization of hepatocellular carcinoma (HCC) does not reliably predict long-term response to treatment. This study evaluated whether quantitative contrast-enhanced ultrasound (CEUS) can predict the long-term response of HCC to yttrium-90 (Y-90) treatment. Fifteen patients underwent CEUS at three time points: immediately following treatment and 1 and 2 wk post-treatment. Response 3-6 mo after treatment was categorized on contrast-enhanced magnetic resonance imaging by two experienced radiologists using the Modified Response Evaluation Criteria in Solid Tumors. CEUS data were analyzed by quantifying tumor perfusion and residual fractional vascularity using time-intensity curves. Patients with stable disease on magnetic resonance imaging had significantly greater fractional vascularity 2 wk post-treatment (65.15%) than those with partial or complete response (13.8 ± 9.9%, p = 0.007, and 14.9 ± 15.4%, p = 0.009, respectively). Complete responders had lower tumor vascularity at 2 wk than at post-operative examination (-38.3 ± 15.4%, p = 0.045). Thus, this pilot study suggests CEUS may provide an earlier indication of Y-90 treatment response than cross-sectional imaging.
Collapse
Affiliation(s)
- Lauren J Delaney
- Department of Radiology, Thomas Jefferson University, Philadelphia, Pennsylvania, USA
| | - Mohamed Tantawi
- Department of Radiology, Thomas Jefferson University, Philadelphia, Pennsylvania, USA
| | - Corinne E Wessner
- Department of Radiology, Thomas Jefferson University, Philadelphia, Pennsylvania, USA
| | - Priscilla Machado
- Department of Radiology, Thomas Jefferson University, Philadelphia, Pennsylvania, USA
| | - Flemming Forsberg
- Department of Radiology, Thomas Jefferson University, Philadelphia, Pennsylvania, USA
| | - Andrej Lyshchik
- Department of Radiology, Thomas Jefferson University, Philadelphia, Pennsylvania, USA
| | - Patrick O'Kane
- Department of Radiology, Thomas Jefferson University, Philadelphia, Pennsylvania, USA
| | - Ji-Bin Liu
- Department of Radiology, Thomas Jefferson University, Philadelphia, Pennsylvania, USA
| | - Jesse Civan
- Division of Gastroenterology and Hepatology, Department of Medicine, Thomas Jefferson University, Philadelphia, Pennsylvania, USA
| | - Allison Tan
- Department of Radiology, Thomas Jefferson University, Philadelphia, Pennsylvania, USA
| | - Kevin Anton
- Department of Radiology, Thomas Jefferson University, Philadelphia, Pennsylvania, USA
| | - Colette M Shaw
- Department of Radiology, Thomas Jefferson University, Philadelphia, Pennsylvania, USA
| | - John R Eisenbrey
- Department of Radiology, Thomas Jefferson University, Philadelphia, Pennsylvania, USA.
| |