1
|
Zhang Y, Fang X, Luo L, Xiong Y, Zhang W, Gou Y, Gong C, Xiang Z, Kuang F, Duan H. Clinical Analysis of Microwave Ablation Combined with Decompression and Pedicle Screw Fixation in the Treatment of Spinal Metastases. Orthop Surg 2024; 16:1292-1299. [PMID: 38644512 PMCID: PMC11144500 DOI: 10.1111/os.14063] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 11/29/2023] [Revised: 03/18/2024] [Accepted: 03/19/2024] [Indexed: 04/23/2024] Open
Abstract
OBJECTIVES There is still controversy over the choice of treatment for end-stage spinal metastases. With the continuous development of microwave technology in spinal tumors, related studies have reported that microwave combined with techniques such as pedicle screw fixation and percutaneous vertebroplasty can achieve the purpose of tumor ablation, relieving spinal cord compression, enhancing spinal stability, effectively relieving pain, and reducing recurrence rates. This study aimed to analyze the effectiveness of microwave ablation combined with decompression and pedicle screw fixation in the palliative management of spinal metastases with pathological fractures. METHODS This retrospective study enrolled 82 patients with spinal metastases and pathological fractures treated between January 2016 and July 2020, with 44 patients undergoing pedicle screw fixation along with laminectomy (fixation group) and the remaining 38 receiving microwave ablation in addition to the treatment provided to group fixation (MWA group). Before surgery, all patients underwent pain assessment using the visual analogue scale (VAS) and evaluation of spinal cord injury using the Frankel classification. After surgery, the patients' prognoses were assessed using the Tomita score, modified Tokuhashi score system, and progression-free survival. Additionally, we compared operative time and blood loss between the two groups. Survival analysis utilized the Kaplan-Meier method with a log-rank test for group comparisons. Paired t-tests and the Mann-Whitney U test were applied to metric and non-normally distributed data, respectively. Neurological function improvement across groups was evaluated using the χ2 test. RESULTS All patients were followed up for a median duration of 18 and 20 months in the fixation and MWA groups, respectively, with follow-up periods ranging from 6 to 36 months. Statistically significant reductions in postoperative VAS scores were observed in all patients compared with their preoperative scores. The MWA group exhibited reduced blood loss (t = 2.74, p = 0.01), lower VAS scores at the 1- and 3-month follow-ups (t = 2.34, P = 0.02; t = 2.83, p = 0.006), and longer progression-free survival than the fixation group (p = 0.03). Although the operation times in the MWA group were longer than those in the fixation group, this difference was not statistically significant (t = 6.06, p = 0.12). No statistically significant differences were found regarding improvements in spinal cord function between the two groups (p = 0.77). CONCLUSION Compared with decompression and pedicle screw fixation for treating spinal metastases with pathological fractures, microwave ablation combined with decompression and pedicle screw fixation showed better outcomes in terms of pain control, longer progression-free survival, and lower blood loss without increasing operative time, which has favorable implications for clinical practice.
Collapse
Affiliation(s)
- Yangming Zhang
- Department of OrthopedicsWest China Hospital, Sichuan UniversityChengduChina
| | - Xiang Fang
- Department of OrthopedicsWest China Hospital, Sichuan UniversityChengduChina
| | - Lin Luo
- Department of OrthopedicsPeople's Fourth Hospital of Sichuan ProvinceChengduChina
| | - Yan Xiong
- Department of OrthopedicsWest China Hospital, Sichuan UniversityChengduChina
| | - Wenli Zhang
- Department of OrthopedicsWest China Hospital, Sichuan UniversityChengduChina
| | - Yawei Gou
- Department of OrthopedicsPeople's Fourth Hospital of Sichuan ProvinceChengduChina
| | - Chunfu Gong
- Department of OrthopedicsPeople's Fourth Hospital of Sichuan ProvinceChengduChina
| | - Zhou Xiang
- Department of OrthopedicsWest China Hospital, Sichuan UniversityChengduChina
| | - Fuguo Kuang
- Department of OrthopedicsPeople's Fourth Hospital of Sichuan ProvinceChengduChina
| | - Hong Duan
- Department of OrthopedicsWest China Hospital, Sichuan UniversityChengduChina
| |
Collapse
|
2
|
Fang Z, Wu C, Cao L, Wang T, Hong X, Moser MAJ, Zhang W, Zhang B. Development of non-invasive flexible directional microwave ablation for central lung cancer: a simulation study. Phys Med Biol 2024; 69:09NT04. [PMID: 38527368 DOI: 10.1088/1361-6560/ad3795] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/13/2023] [Accepted: 03/25/2024] [Indexed: 03/27/2024]
Abstract
Transbronchial microwave ablation (MWA) with flexible antennas has gradually become an attractive alternative to percutaneous MWA for lung cancer due to its characteristic of non-invasiveness. However, flexible antennas for the precision ablation of lung tumors that are adjacent to critical bronchial structures are still not available. In this study, a non-invasive flexible directional (FD) antenna for early stage central lung tumors surrounding the bronchia was proposed. A comprehensive numerical MWA model with the FD antenna was developed in a real human-sized left lung model. The structure of the antenna and the treatment protocol were optimized by a generic algorithm for the precision ablation of two cases of early stage central lung cancer (i.e. spherical-like and ellipsoidal tumors). The electromagnetic efficiency of the optimized antenna was also improved by implementing an optimizedπ-matching network for impedance matching. The results indicate that the electromagnetic energy of MWA can be restricted to a particular area for precision ablation of specific lung tumors using the FD antenna. This study contributes to the field of lung cancer management with MWA.
Collapse
Affiliation(s)
- Zheng Fang
- Intelligent Energy-based Tumor Ablation Laboratory, School of Mechatronic Engineering and Automation, Shanghai University, Shanghai, People's Republic of China
- Department of Mechanical Engineering, University of Saskatchewan, Saskatoon, Canada
| | - Chen Wu
- Intelligent Energy-based Tumor Ablation Laboratory, School of Mechatronic Engineering and Automation, Shanghai University, Shanghai, People's Republic of China
| | - Lin Cao
- Department of Automatic Control and Systems Engineering, the University of Sheffield, Sheffield, United Kingdom
| | - Tao Wang
- Department of Interventional Oncology, Renji Hospital, Shanghai Jiao Tong University School of Medicine, Shanghai, People's Republic of China
| | - Xiaowu Hong
- Department of Immunology, School of Basic Medical Sciences, Fudan University, Shanghai, People's Republic of China
- Research Institute of Fudan University, Ningbo, People's Republic of China
| | - Michael A J Moser
- Department of Surgery, University of Saskatchewan, Saskatoon, Canada
| | - Wenjun Zhang
- Department of Mechanical Engineering, University of Saskatchewan, Saskatoon, Canada
| | - Bing Zhang
- Intelligent Energy-based Tumor Ablation Laboratory, School of Mechatronic Engineering and Automation, Shanghai University, Shanghai, People's Republic of China
| |
Collapse
|
3
|
Pfannenstiel A, Avellar H, Hallman C, Plattner BL, Highland MA, Cornelis FH, Beard WL, Prakash P. Directional microwave ablation in spine: experimental assessment of computational modeling. Int J Hyperthermia 2024; 41:2313492. [PMID: 38369302 PMCID: PMC11357707 DOI: 10.1080/02656736.2024.2313492] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/29/2023] [Accepted: 01/30/2024] [Indexed: 02/20/2024] Open
Abstract
BACKGROUND Despite the theoretical advantages of treating metastatic bone disease with microwave ablation (MWA), there are few reports characterizing microwave absorption and bioheat transfer in bone. This report describes a computational modeling-based approach to simulate directional microwave ablation (dMWA) in spine, supported by ex vivo and pilot in vivo experiments in porcine vertebral bodies. MATERIALS AND METHODS A 3D computational model of microwave ablation within porcine vertebral bodies was developed. Ex vivo porcine vertebra experiments using a dMWA applicator measured temperatures approximately 10.1 mm radially from the applicator in the direction of MW radiation (T1) and approximately 2.4 mm in the contra-lateral direction (T2). Histologic assessment of ablated ex vivo tissue was conducted and experimental results compared to simulations. Pilot in vivo experiments in porcine vertebral bodies assessed ablation zones histologically and with CT and MRI. RESULTS Experimental T1 and T2 temperatures were within 3-7% and 11-33% of simulated temperature values. Visible ablation zones, as indicated by grayed tissue, were smaller than those typical in other soft tissues. Posthumous MRI images of in vivo ablations showed hyperintensity. In vivo experiments illustrated the technical feasibility of creating directional microwave ablation zones in porcine vertebral body. CONCLUSION Computational models and experimental studies illustrate the feasibility of controlled dMWA in bone tissue.
Collapse
Affiliation(s)
- Austin Pfannenstiel
- Precision Microwave Inc, Manhattan, KS, USA
- Department of Electrical and Computer Engineering, KS State University, Manhattan, KS, USA
| | - Haileigh Avellar
- Department of Clinical Sciences, Kansas State University, Manhattan, KS, USA
| | - Clay Hallman
- Department of Clinical Sciences, Kansas State University, Manhattan, KS, USA
| | - Brandon L. Plattner
- Department of Diagnostic Medicine/Pathobiology and Kansas State Veterinary Diagnostic Laboratory, Kansas State University, Manhattan, KS, USA
| | - Margaret A. Highland
- WI Veterinary Diagnostic Laboratory, University of Wisconsin-Madison, Madison, WI, USA
| | - Francois H. Cornelis
- Interventional Radiology Service, Memorial Sloan Kettering Cancer Center, NY, NY, USA
| | - Warren L. Beard
- Department of Clinical Sciences, Kansas State University, Manhattan, KS, USA
| | - Punit Prakash
- Department of Electrical and Computer Engineering, KS State University, Manhattan, KS, USA
| |
Collapse
|
4
|
Servin F, Collins JA, Heiselman JS, Frederick-Dyer KC, Planz VB, Geevarghese SK, Brown DB, Jarnagin WR, Miga MI. Simulation of Image-Guided Microwave Ablation Therapy Using a Digital Twin Computational Model. IEEE OPEN JOURNAL OF ENGINEERING IN MEDICINE AND BIOLOGY 2023; 5:107-124. [PMID: 38445239 PMCID: PMC10914207 DOI: 10.1109/ojemb.2023.3345733] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/01/2023] [Revised: 08/14/2023] [Accepted: 12/04/2023] [Indexed: 03/07/2024] Open
Abstract
Emerging computational tools such as healthcare digital twin modeling are enabling the creation of patient-specific surgical planning, including microwave ablation to treat primary and secondary liver cancers. Healthcare digital twins (DTs) are anatomically one-to-one biophysical models constructed from structural, functional, and biomarker-based imaging data to simulate patient-specific therapies and guide clinical decision-making. In microwave ablation (MWA), tissue-specific factors including tissue perfusion, hepatic steatosis, and fibrosis affect therapeutic extent, but current thermal dosing guidelines do not account for these parameters. This study establishes an MR imaging framework to construct three-dimensional biophysical digital twins to predict ablation delivery in livers with 5 levels of fat content in the presence of a tumor. Four microwave antenna placement strategies were considered, and simulated microwave ablations were then performed using 915 MHz and 2450 MHz antennae in Tumor Naïve DTs (control), and Tumor Informed DTs at five grades of steatosis. Across the range of fatty liver steatosis grades, fat content was found to significantly increase ablation volumes by approximately 29-l42% in the Tumor Naïve and 55-60% in the Tumor Informed DTs in 915 MHz and 2450 MHz antenna simulations. The presence of tumor did not significantly affect ablation volumes within the same steatosis grade in 915 MHz simulations, but did significantly increase ablation volumes within mild-, moderate-, and high-fat steatosis grades in 2450 MHz simulations. An analysis of signed distance to agreement for placement strategies suggests that accounting for patient-specific tumor tissue properties significantly impacts ablation forecasting for the preoperative evaluation of ablation zone coverage.
Collapse
Affiliation(s)
- Frankangel Servin
- Department of Biomedical EngineeringVanderbilt UniversityNashvilleTN37235USA
- Vanderbilt Institute for Surgery and EngineeringVanderbilt UniversityNashvilleTN37235USA
| | - Jarrod A. Collins
- Department of Biomedical EngineeringVanderbilt UniversityNashvilleTN37235USA
| | - Jon S. Heiselman
- Department of Biomedical EngineeringVanderbilt UniversityNashvilleTN37235USA
- Vanderbilt Institute for Surgery and EngineeringVanderbilt UniversityNashvilleTN37235USA
- Department of Surgery, Hepatopancreatobiliary ServiceMemorial Sloan Kettering Cancer CenterNew YorkNY10065USA
| | | | - Virginia B. Planz
- Department of RadiologyVanderbilt University Medical CenterNashvilleTN37235USA
| | | | - Daniel B. Brown
- Department of RadiologyVanderbilt University Medical CenterNashvilleTN37235USA
| | - William R. Jarnagin
- Department of Surgery, Hepatopancreatobiliary ServiceMemorial Sloan Kettering Cancer CenterNew YorkNY10065USA
| | - Michael I. Miga
- Department of Biomedical EngineeringVanderbilt UniversityNashvilleTN37235USA
- Vanderbilt Institute for Surgery and EngineeringVanderbilt UniversityNashvilleTN37235USA
- Department of RadiologyVanderbilt University Medical CenterNashvilleTN37235USA
- Department of Neurological SurgeryVanderbilt University Medical CenterNashvilleTN37235USA
- Department of OtolaryngologyVanderbilt University Medical CenterNashvilleTN37235USA
| |
Collapse
|
5
|
Wu C, Huang H, Liu Y, Chen L, Yu S, Moser MAJ, Zhang W, Fang Z, Zhang B. Optimal design of aperiodic tri-slot antennas for the conformal ablation of liver tumors using an experimentally validated MWA computer model. COMPUTER METHODS AND PROGRAMS IN BIOMEDICINE 2023; 242:107799. [PMID: 37703699 DOI: 10.1016/j.cmpb.2023.107799] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 02/20/2023] [Revised: 09/03/2023] [Accepted: 09/03/2023] [Indexed: 09/15/2023]
Abstract
OBJECTIVE This study aims to demonstrate that the conformal microwave ablation (MWA) of liver tumors could be attained by optimizing the structure of an aperiodic tri-slot coaxial antenna, its insertion depth, and input power. METHODS A computational MWA model with an aperiodic tri-slot coaxial antenna operating at the frequency of 2.45 GHz was built and validated by both an ex vivo and a pilot in vivo experiment with porcine healthy livers. The validated in vivo computational MWA model implemented with a liver tumor was then used as a testbed to investigate the conformal ablation of liver tumors. Five liver tumors in different sizes and shapes were investigated. A genetic algorithm optimization method (NSGA-II) was used to optimize the structure of antenna, insertion depth of antenna, and microwave antenna input power for the conformal ablation of liver tumors. RESULTS The validation results showed that a good agreement in both the spatiotemporal temperature distribution and ablation zone was found between the computer model and the ex vivo experiments at both 45 W, 5 min and 60 W, 3 min treatments and the in vivo experiment at 45 W, 5 min treatment. The optimized simulation results confirmed that five cases of liver tumors in different sizes and shapes can be conformally ablated by optimizing the aperiodic tri-slot coaxial antenna, antenna insertion depth, and microwave antenna input power. CONCLUSION This paper demonstrates that the aperiodic tri-slot coaxial antenna can be optimized with the insertion depth and input power for the conformal ablation of liver tumors, regardless the size and shape of liver tumors.
Collapse
Affiliation(s)
- Chen Wu
- Intelligent Energy-based Tumor Ablation Laboratory, School of Mechatronic Engineering and Automation, Shanghai University, Shanghai 200444, China
| | - Hangming Huang
- Intelligent Energy-based Tumor Ablation Laboratory, School of Mechatronic Engineering and Automation, Shanghai University, Shanghai 200444, China
| | - Yongfang Liu
- Shanghai Advanced Research Institute, Chinese Academy of Sciences, Shanghai 201412, China
| | - Lingchao Chen
- Department of Neurosurgery, Huashan Hospital Shanghai Medical College, Fudan University, Shanghai 200040, China
| | - Shuangquan Yu
- Department of Neurosurgery, Huashan Hospital Shanghai Medical College, Fudan University, Shanghai 200040, China
| | - Michael A J Moser
- Department of Surgery, University of Saskatchewan, Saskatoon, Canada
| | - Wenjun Zhang
- Department of Mechanical Engineering, University of Saskatchewan, Saskatoon, Canada
| | - Zheng Fang
- Department of Mechanical Engineering, University of Saskatchewan, Saskatoon, Canada.
| | - Bing Zhang
- Intelligent Energy-based Tumor Ablation Laboratory, School of Mechatronic Engineering and Automation, Shanghai University, Shanghai 200444, China.
| |
Collapse
|
6
|
Bottiglieri A, Brace C, O’Halloran M, Farina L. MWA Performed at 5.8 GHz through 'Side Firing' Approach: An Exploratory Study. SENSORS (BASEL, SWITZERLAND) 2022; 22:9320. [PMID: 36502019 PMCID: PMC9735527 DOI: 10.3390/s22239320] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 11/02/2022] [Revised: 11/28/2022] [Accepted: 11/28/2022] [Indexed: 06/17/2023]
Abstract
Recent studies have shown that ablation techniques have the potential to eradicate adrenal adenomas while preserving the functionalities of the adrenal gland and the surrounding anatomical structures. This study explores a new microwave ablation (MWA) approach operating at 5.8 GHz and using anatomical and dielectric characteristics of the target tissue to create directional heating patterns. Numerical simulations are executed in planar and 3D adrenal models, considering two energy doses. The numerical study is refined accounting for the vaporization of the tissue water content. Ex vivo experimental evaluations on porcine adrenal models complete the study. The numerical and experimental results show that spherical ablation zones are able to cover the target for both energy doses considered. Nonetheless, most of the non-targeted tissues can be preserved from excessive heating when low energy level is used. Numerical models accounting for water vaporization are capable to foresee the experimental temperature values. This study shows that the proposed MWA directional approach operating at 5.8 GHz can be considered for creating effective and selective ablation zones.
Collapse
Affiliation(s)
- Anna Bottiglieri
- Electrical and Electronic Engineering, National University of Ireland Galway, H91 TK33 Galway, Ireland
- Translational Medical Device Lab, National University of Ireland Galway, H91 TK33 Galway, Ireland
| | - Christopher Brace
- Department of Biomedical Engineering, University of Wisconsin-Madison, 1415 Engineering Drive, Madison, WI 53706, USA
- Department of Radiology, University of Wisconsin-Madison, 1111 Highland Ave, Madison, WI 53705, USA
| | - Martin O’Halloran
- Translational Medical Device Lab, National University of Ireland Galway, H91 TK33 Galway, Ireland
| | - Laura Farina
- Translational Medical Device Lab, National University of Ireland Galway, H91 TK33 Galway, Ireland
| |
Collapse
|
7
|
Hung CM, Tai CC. Liver tumor ablation enhancement by induction-heating system with bitter-like deep magnetic field coil. THE REVIEW OF SCIENTIFIC INSTRUMENTS 2022; 93:054107. [PMID: 35649808 DOI: 10.1063/5.0066308] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 08/10/2021] [Accepted: 04/23/2022] [Indexed: 06/15/2023]
Abstract
The heated metal needle used for tumor thermotherapy is considered crucial for enhancing the practicality of cauterization using electromagnetic induction-heating techniques. In this study, a novel coil capable of producing a deep magnetic field is designed. In the proposed design, the coil structure is improved to enhance the intensity of the coil's deep magnetic field and its suitability for deep-tissue cauterization. Furthermore, a series of experiments are conducted using a single and consistent input current. The heating experiments are conducted at varying depths by placing the needle beneath the coil. The proposed coil significantly increases the induction-heating temperature and provides a solution to the long-standing problem of insufficient needle temperature. This research has also improved the usability of the induction-heating equipment in the field of deep tumor ablation.
Collapse
Affiliation(s)
- Chia-Ming Hung
- Department of Electrical Engineering, National Cheng Kung University, Tainan City 70101, Taiwan
| | - Cheng-Chi Tai
- Department of Electrical Engineering, National Cheng Kung University, Tainan City 70101, Taiwan
| |
Collapse
|
8
|
Pfannenstiel A, Iannuccilli J, Cornelis FH, Dupuy DE, Beard WL, Prakash P. Shaping the future of microwave tumor ablation: a new direction in precision and control of device performance. Int J Hyperthermia 2022; 39:664-674. [DOI: 10.1080/02656736.2021.1991012] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/16/2023] Open
Affiliation(s)
- Austin Pfannenstiel
- Precision Microwave Inc, Manhattan, KS, USA
- Department of Electrical and Computer Engineering, Kansas State University, Manhattan, KS, USA
| | - Jason Iannuccilli
- Department of Diagnostic Imaging, Division of Interventional Oncology, Rhode Island Hospital, Providence, RI, USA
| | - Francois H. Cornelis
- Interventional Radiology Service, Memorial Sloan Kettering Cancer Center, NY, USA
| | - Damian E. Dupuy
- Diagnostic Imaging, Brown University, Radiology, Cape Cod Hospital, MA, USA
| | - Warren L. Beard
- Department of Clinical Sciences, Kansas State University, Manhattan, KS, USA
| | - Punit Prakash
- Department of Electrical and Computer Engineering, Kansas State University, Manhattan, KS, USA
| |
Collapse
|
9
|
Sebek J, Cappiello G, Rahmani G, Zeinali N, Keating M, Fayemiwo M, Harkin J, McDaid L, Gardiner B, Sheppard D, Senanayake R, Gurnell M, O’Halloran M, Dennedy MC, Prakash P. Image-based computer modeling assessment of microwave ablation for treatment of adrenal tumors. Int J Hyperthermia 2022; 39:1264-1275. [PMID: 36137605 PMCID: PMC9820798 DOI: 10.1080/02656736.2022.2125590] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/11/2023] Open
Abstract
PURPOSE To assess the feasibility of delivering microwave ablation for targeted treatment of aldosterone producing adenomas using image-based computational models. METHODS We curated an anonymized dataset of diagnostic 11C-metomidate PET/CT images of 14 patients with aldosterone producing adenomas (APA). A semi-automated approach was developed to segment the APA, adrenal gland, and adjacent organs within 2 cm of the APA boundary. The segmented volumes were used to implement patient-specific 3D electromagnetic-bioheat transfer models of microwave ablation with a 2.45 GHz directional microwave ablation applicator. Ablation profiles were quantitatively assessed based on the extent of the APA target encompassed by an ablative thermal dose, while limiting thermal damage to the adjacent normal adrenal tissue and sensitive critical structures. RESULTS Across the 14 patients, adrenal tumor volumes ranged between 393 mm3 and 2,395 mm3. On average, 70% of the adrenal tumor volumes received an ablative thermal dose of 240CEM43, while limiting thermal damage to non-target structures, and thermally sparing 83.5-96.4% of normal adrenal gland. Average ablation duration was 293 s (range: 60-600 s). Simulations indicated coverage of the APA with an ablative dose was limited when the axis of the ablation applicator was not well aligned with the major axis of the targeted APA. CONCLUSIONS Image-based computational models demonstrate the potential for delivering microwave ablation to APA targets within the adrenal gland, while limiting thermal damage to surrounding non-target structures.
Collapse
Affiliation(s)
- Jan Sebek
- Mike Wiegers Department of Electrical and Computer Engineering, Kansas State University, Manhattan, KS 66506, USA
| | - Grazia Cappiello
- Translational Medical Devices Lab, National University of Ireland, Galway, Republic of Ireland
| | - George Rahmani
- Department of Radiology, Galway University Hospitals, Galway, Republic Ireland
| | - Nooshin Zeinali
- Mike Wiegers Department of Electrical and Computer Engineering, Kansas State University, Manhattan, KS 66506, USA
| | - Muireann Keating
- School of Medicine, National University of Ireland, Galway, Republic Ireland
| | - Michael Fayemiwo
- School of Computing, Engineering, and Intelligent Systems, Ulster University, Londonderry, Northern Ireland
| | - Jim Harkin
- School of Computing, Engineering, and Intelligent Systems, Ulster University, Londonderry, Northern Ireland
| | - Liam McDaid
- School of Computing, Engineering, and Intelligent Systems, Ulster University, Londonderry, Northern Ireland
| | - Bryan Gardiner
- School of Computing, Engineering, and Intelligent Systems, Ulster University, Londonderry, Northern Ireland
| | - Declan Sheppard
- Department of Radiology, Galway University Hospitals, Galway, Republic Ireland
| | | | - Mark Gurnell
- Institute of Metabolic Science, University of Cambridge, United Kingdom
| | - Martin O’Halloran
- Translational Medical Devices Lab, National University of Ireland, Galway, Republic of Ireland
| | - M. Conall Dennedy
- School of Medicine, National University of Ireland, Galway, Republic Ireland
| | - Punit Prakash
- Mike Wiegers Department of Electrical and Computer Engineering, Kansas State University, Manhattan, KS 66506, USA.,Author to whom correspondence should be addressed: Punit Prakash, 3078 Engineering Hall, 1701D Platt St, Kansas State University, Manhattan, KS 66506, USA.
| |
Collapse
|
10
|
Donlon P, Dennedy MC. Thermal ablation in adrenal disorders: a discussion of the technology, the clinical evidence and the future. Curr Opin Endocrinol Diabetes Obes 2021; 28:291-302. [PMID: 33741778 PMCID: PMC8183491 DOI: 10.1097/med.0000000000000627] [Citation(s) in RCA: 10] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 12/14/2022]
Abstract
PURPOSE OF REVIEW To summarise the emerging role of thermal ablation as a therapeutic modality in the management of functioning adrenal tumours and metastases to the adrenal gland. RECENT FINDINGS Observational evidence has demonstrated the benefit of thermal ablation in (i) resolving adrenal endocrinopathy arising from benign adenomas, (ii) treating solitary metastases to the adrenal and (iii) controlling metastatic adrenocortical carcinoma and phaeochromocytoma/paraganglioma. SUMMARY Microwave thermal ablation offers a promising, minimally invasive therapeutic modality for the management of functioning adrenocortical adenomas and adrenal metastases. Appropriate technological design, treatment planning and choice of imaging modality are necessary to overcome technical challenges associated with this emerging therapeutic approach.
Collapse
Affiliation(s)
- Padraig Donlon
- Adrenal Research Laboratory, The Discipline of Pharmacology and Therapeutics, Lambe Institute for Translational Research, School of Medicine, National University of Ireland Galway, Ireland
| | | |
Collapse
|
11
|
Huang H, Zhang L, Moser MAJ, Zhang W, Zhang B. A review of antenna designs for percutaneous microwave ablation. Phys Med 2021; 84:254-264. [PMID: 33773908 DOI: 10.1016/j.ejmp.2021.03.010] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 11/29/2020] [Revised: 03/03/2021] [Accepted: 03/06/2021] [Indexed: 12/15/2022] Open
Abstract
Microwave (MW) antenna is a key element in microwave ablation (MWA) treatments as the means that energy is delivered in a focused manner to the tumor and its surrounding area. The energy delivered results in a rise in temperature to a lethal level, resulting in cell death in the ablation zone. The delivery of energy and hence the success of MWA is closely dependent on the structure of the antennas. Therefore, three design criteria, such as expected ablation zone pattern, efficiency of energy delivery, and minimization of the diameter of the antennas have been the focus along the evolution of the MW antenna. To further improve the performance of MWA in the treatment of various tumors through inventing novel antennas, this article reviews the state-of-the-art and summarizes the development of MW antenna designs regarding the three design criteria.
Collapse
Affiliation(s)
- Hangming Huang
- Energy-based Tumor Ablation Laboratory, School of Mechatronic Engineering and Automation, Shanghai University, Shanghai, China
| | - Lifeng Zhang
- Department of General Surgery, the First Affiliated Hospital of Soochow University,Soochow University, Jiangsu, China
| | - Michael A J Moser
- Department of Surgery, College of Medicine, University of Saskatchewan, Saskatoon, Canada
| | - Wenjun Zhang
- Division of Biomedical Engineering, College of Engineering, University of Saskatchewan, Saskatoon, Canada
| | - Bing Zhang
- Energy-based Tumor Ablation Laboratory, School of Mechatronic Engineering and Automation, Shanghai University, Shanghai, China.
| |
Collapse
|
12
|
Bottiglieri A, Ruvio G, O’Halloran M, Farina L. Exploiting Tissue Dielectric Properties to Shape Microwave Thermal Ablation Zones. SENSORS 2020; 20:s20143960. [PMID: 32708680 PMCID: PMC7411896 DOI: 10.3390/s20143960] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 06/03/2020] [Revised: 07/07/2020] [Accepted: 07/14/2020] [Indexed: 02/07/2023]
Abstract
The dielectric characterization of tissue targets of microwave thermal ablation (MTA) have improved the efficacy and pre-procedural planning of treatment. In some clinical scenarios, the tissue target lies at the interface with an external layer of fat. The aim of this work is to investigate the influence of the dielectric contrast between fat and target tissue on the shape and size of the ablation zone. A 2.45 GHz monopole antenna is placed parallel to an interface modelled by fat and a tissue characterized by higher dielectric properties and powered at 30 and 60 W for 60 s. The performances of MTA are numerically investigated considering different interface scenarios (i.e., different widths of fat layer, shifts in the antenna alignment) and a homogeneous reference scenario. Experiments (N = 10) are conducted on ex vivo porcine tissue to validate the numerical results. Asymmetric heating patterns are obtained in the interface scenario, the ablation zone in the target tissue is two-fold to ten-fold the size of the zone in the adipose tissue, and up to four times larger than the homogenous scenario. The adipose tissue reflects the electromagnetic energy into the adjacent tissue target, reducing the heating in the opposite direction.
Collapse
Affiliation(s)
- Anna Bottiglieri
- Electrical and Electronic Engineering, National University of Ireland Galway, H91 TK33 Galway, Ireland
- Translational Medical Device Lab, National University of Ireland Galway, H91 TK33 Galway, Ireland; (G.R.); (L.F.)
- Correspondence: (A.B.); (M.O.)
| | - Giuseppe Ruvio
- Translational Medical Device Lab, National University of Ireland Galway, H91 TK33 Galway, Ireland; (G.R.); (L.F.)
- Endowave Ltd., National University of Ireland Galway, H91 TK33 Galway, Ireland
| | - Martin O’Halloran
- Translational Medical Device Lab, National University of Ireland Galway, H91 TK33 Galway, Ireland; (G.R.); (L.F.)
- Correspondence: (A.B.); (M.O.)
| | - Laura Farina
- Translational Medical Device Lab, National University of Ireland Galway, H91 TK33 Galway, Ireland; (G.R.); (L.F.)
- CÚRAM, SFI Research Centre for Medical Devices, H91 TK33 Galway, Ireland
| |
Collapse
|
13
|
Directional Microwave Ablation: Experimental Evaluation of a 2.45-GHz Applicator in Ex Vivo and In Vivo Liver. J Vasc Interv Radiol 2020; 31:1170-1177.e2. [PMID: 32171539 DOI: 10.1016/j.jvir.2020.01.016] [Citation(s) in RCA: 10] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/31/2019] [Revised: 01/14/2020] [Accepted: 01/17/2020] [Indexed: 12/19/2022] Open
Abstract
PURPOSE To experimentally characterize a microwave (MW) ablation applicator designed to produce directional ablation zones. MATERIALS AND METHODS Using a 14-gauge, 2.45-GHz side-firing MW ablation applicator, 36 ex vivo bovine liver ablations were performed. Ablations were performed at 60 W, 80 W, and 100 W for 3, 5, and 10 minutes (n = 4 per combination). Ablation zone forward and backward depth and width were measured and directivity was calculated as the ratio of forward to backward depth. Thirteen in vivo ablations were performed in 2 domestic swine with the applicator either inserted into the liver (80 W, 5 min, n = 3; 100 W, 5 min, n = 3; 100 W, 10 min, n = 2) or placed on the surface of the liver with a nontarget tissue placed on the back side of the applicator (80 W, 5 min, n = 5). The animals were immediately euthanized after the procedure; the livers were harvested and sectioned perpendicular to the axis of the applicator. In vivo ablation zones were measured following viability staining and assessed on histopathology. RESULTS Mean ex vivo ablation forward depth was 8.3-15.5 mm. No backward heating was observed at 60 W, 3-5 minutes; directivity was 4.7-11.0 for the other power and time combinations. In vivo ablation forward depth was 10.3-11.5 mm, and directivity was 11.5-16.1. No visible or microscopic thermal damage to nontarget tissues in direct contact with the back side of the applicator was observed. CONCLUSIONS The side-firing MW ablation applicator can create directional ablation zones in ex vivo and in vivo tissues.
Collapse
|
14
|
Faridi P, Bossmann SH, Prakash P. Simulation-based design and characterization of a microwave applicator for MR-guided hyperthermia experimental studies in small animals. Biomed Phys Eng Express 2020; 6:015001. [PMID: 32999735 PMCID: PMC7521833 DOI: 10.1088/2057-1976/ab36dd] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/28/2023]
Abstract
Purpose The objective of this study was to design and characterize a 2.45 GHz microwave hyperthermia applicator for delivering hyperthermia in experimental small animals to 2 - 4 mm diameter targets located 1 - 3 mm from the skin surface, with minimal heating of the surrounding tissue, under 14.1 T MRI real-time monitoring and feedback control. Materials and methods An experimentally validated 3D computational model was employed to design and characterize a non-invasive directional water-cooled microwave hyperthermia applicator. We assessed the effects of: reflector geometry, monopole shape, cooling water temperature, and flow rate on spatial-temperature profiles. The system was integrated with real-time MR thermometry and feedback control to monitor and maintain temperature elevations in the range of 4 - 5 °C at 1 - 3 mm from the applicator surface. The quality of heating was quantified by determining the fraction of the target volume heated to the desired temperature, and the extent of heating in non-targeted regions. Results Model-predicted hyperthermic profiles were in good agreement with experimental measurements (Dice Similarity Coefficient of 0.95 - 0.99). Among the four considered criteria, a reflector aperture angle of 120 °, S-shaped monopole antenna with 0.6 mm displacement, and coolant flow rate of 150 ml/min were selected as the end result of the applicator design. The temperature of circulating water and input power were identified as free variables, allowing considerable flexibility in heating target sizes within varying distances from the applicator surface. 2 - 4 mm diameter targets positioned 1 - 3 mm from the applicator surface were heated to hyperthermic temperatures, with target coverage ratio ranging between 76 - 93 % and 11 - 26 % of non-targeted tissue heated. Conclusion We have designed an experimental platform for MR-guided hyperthermia, incorporating a microwave applicator integrated with temperature-based feedback control to heat deep-seated targets for experimental studies in small animals.
Collapse
Affiliation(s)
- Pegah Faridi
- Department of Electrical and Computer Engineering, Kansas State University, Manhattan, KS 66506, USA
| | - Stefan H. Bossmann
- Department of Chemistry, Kansas State University, Manhattan, KS 66506, USA
| | - Punit Prakash
- Department of Electrical and Computer Engineering, Kansas State University, Manhattan, KS 66506, USA
| |
Collapse
|
15
|
Abstract
Microwave (MW) ablation has emerged as a minimally invasive therapeutic modality and is in clinical use for treatment of unresectable tumors and cardiac arrhythmias, neuromodulation, endometrial ablation, and other applications. Components of image-guided MW ablation systems include high-power MW sources, ablation applicators that deliver power from the generator to the target tissue, cooling systems, energy-delivery control algorithms, and imaging guidance systems tailored to specific clinical indications. The applicator incorporates a MW antenna that radiates MW power into the surrounding tissue. A variety of antenna designs have been developed for MW ablation with the objective of efficiently transferring MW power to tissue, with a radiation pattern well matched to the size and shape of the targeted tissue. Here, we survey advances in percutaneous, endocavitary, and endoscopic antenna designs as an integral element of MW ablation applicators for a diverse set of clinical applications.
Collapse
Affiliation(s)
- Hojjatollah Fallahi
- Department of Electrical and Computer Engineering, Kansas State University, Manhattan, Kansas
| | - Punit Prakash
- Department of Electrical and Computer Engineering, Kansas State University, Manhattan, Kansas
| |
Collapse
|
16
|
Dundas AA, Hook AL, Alexander MR, Kingman SW, Dimitrakis G, Irvine DJ. Methodology for the synthesis of methacrylate monomers using designed single mode microwave applicators. REACT CHEM ENG 2019. [DOI: 10.1039/c9re00173e] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/11/2023]
Abstract
A novel single-well prototype high throughput microwave reactor geometry has been produced and shown to be capable of synthesizing an array of non-commercially available methacrylate monomers.
Collapse
Affiliation(s)
- Adam A. Dundas
- Department of Chemical and Environmental Engineering
- Faculty of Engineering
- University of Nottingham
- UK
- Advanced Materials and Healthcare Technologies
| | - Andrew L. Hook
- Advanced Materials and Healthcare Technologies
- School of Pharmacy
- University of Nottingham
- UK
| | - Morgan R. Alexander
- Advanced Materials and Healthcare Technologies
- School of Pharmacy
- University of Nottingham
- UK
| | - Samuel W. Kingman
- Department of Chemical and Environmental Engineering
- Faculty of Engineering
- University of Nottingham
- UK
| | - Georgios Dimitrakis
- Department of Chemical and Environmental Engineering
- Faculty of Engineering
- University of Nottingham
- UK
| | - Derek J. Irvine
- Department of Chemical and Environmental Engineering
- Faculty of Engineering
- University of Nottingham
- UK
| |
Collapse
|
17
|
Deshazer G, Hagmann M, Merck D, Sebek J, Moore KB, Prakash P. Computational modeling of 915 MHz microwave ablation: Comparative assessment of temperature-dependent tissue dielectric models. Med Phys 2017; 44:4859-4868. [DOI: 10.1002/mp.12359] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/26/2016] [Revised: 04/20/2017] [Accepted: 04/20/2017] [Indexed: 12/28/2022] Open
Affiliation(s)
- Garron Deshazer
- Department of Radiation Oncology; Siteman Cancer Center; Barnes-Jewish Hospital & Washington University School of Medicine; 4921 Parkview Pl St. Louis MO 63110 USA
- Department of Diagnostic Imaging; Rhode Island Hospital; 593 Eddy Street Providence RI 02903 USA
| | - Mark Hagmann
- Perseon Medical; 2188 W 2200 S Salt Lake City UT 84119 USA
| | - Derek Merck
- Department of Diagnostic Imaging; Rhode Island Hospital; 593 Eddy Street Providence RI 02903 USA
| | - Jan Sebek
- Department of Electrical and Computer Engineering; Kansas State University; Manhattan KS 66506 USA
| | - Kent B. Moore
- Perseon Medical; 2188 W 2200 S Salt Lake City UT 84119 USA
| | - Punit Prakash
- Department of Electrical and Computer Engineering; Kansas State University; Manhattan KS 66506 USA
| |
Collapse
|
18
|
Curto S, Faridi P, Shrestha TB, Pyle M, Maurmann L, Troyer D, Bossmann SH, Prakash P. An integrated platform for small-animal hyperthermia investigations under ultra-high-field MRI guidance. Int J Hyperthermia 2017; 34:341-351. [PMID: 28728442 DOI: 10.1080/02656736.2017.1339126] [Citation(s) in RCA: 18] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/25/2023] Open
Abstract
PURPOSE Integrating small-animal experimental hyperthermia instrumentation with magnetic resonance imaging (MRI) affords real-time monitoring of spatial temperature profiles. This study reports on the development and preliminary in vivo characterisation of a 2.45 GHz microwave hyperthermia system for pre-clinical small animal investigations, integrated within a 14 T ultra-high-field MRI scanner. MATERIALS AND METHODS The presented system incorporates a 3.5 mm (OD) directional microwave hyperthermia antenna, positioned adjacent to the small-animal target, radiating microwave energy for localised heating of subcutaneous tumours. The applicator is integrated within the 30 mm bore of the MRI system. 3D electromagnetic and biothermal simulations were implemented to characterise hyperthermia profiles from the directional microwave antenna. Experiments in tissue mimicking phantoms were performed to assess hyperthermia profiles and validate MR thermometry against fibre-optic temperature measurements. The feasibility of delivering in vivo hyperthermia exposures to subcutaneous 4T1 tumours in experimental mice under simultaneous MR thermometry guidance was assessed. RESULTS Simulations and experiments in tissue mimicking phantoms demonstrated the feasibility of heating 21-982 mm3 targets with 8-12 W input power. Minimal susceptibility and electrical artefacts introduced by the hyperthermia applicator were observed on MR imaging. MR thermometry was in excellent agreement with fibre-optic temperatures measurements (max. discrepancy ≤0.6 °C). Heating experiments with the reported system demonstrated the feasibility of heating subcutaneous tumours in vivo with simultaneous MR thermometry. CONCLUSIONS A platform for small-animal hyperthermia investigations under ultra-high-field MR thermometry was developed and applied to heating subcutaneous tumours in vivo.
Collapse
Affiliation(s)
- Sergio Curto
- a Department of Electrical and Computer Engineering , Kansas State University , Manhattan , KS , USA
| | - Pegah Faridi
- a Department of Electrical and Computer Engineering , Kansas State University , Manhattan , KS , USA
| | - Tej B Shrestha
- b Department of Anatomy and Physiology , Kansas State University , Manhattan , KS , USA
| | - Marla Pyle
- b Department of Anatomy and Physiology , Kansas State University , Manhattan , KS , USA
| | - Leila Maurmann
- c Department of Chemistry , Kansas State University , Manhattan , KS , USA
| | - Deryl Troyer
- b Department of Anatomy and Physiology , Kansas State University , Manhattan , KS , USA
| | - Stefan H Bossmann
- c Department of Chemistry , Kansas State University , Manhattan , KS , USA
| | - Punit Prakash
- a Department of Electrical and Computer Engineering , Kansas State University , Manhattan , KS , USA
| |
Collapse
|
19
|
Sebek J, Curto S, Eaton-Evans J, Bouchier-Hayes J, Ruvio G, Ganta C, Beard W, Buttar N, Song LWK, Prakash P. Feasibility Assessment of Microwave Ablation for Treating Esophageal Varices. J Med Device 2017. [DOI: 10.1115/1.4037187] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/16/2022] Open
Abstract
Esophageal varices are a significant complication of portal hypertension. Endoscopic variceal ligation (EVL) is one of the clinical standards for treating these varices and preventing their hemorrhage. Limitations of EVL include the risk of stricture formation and postband ulcer bleeding due to the damage caused to the esophageal mucosa, as well as the need for multiple endoscopic treatment sessions to eradicate the varices. The goal of this study is to develop a device and evaluate the technical feasibility of microwave ablation to seal esophageal varices, while preventing thermal damage to the surface mucosal tissue. A microwave applicator with a directional radiation pattern was developed for endoscopic ablation of esophageal varices. Electromagnetic and bioheat transfer computational models were employed to optimize the design of the microwave applicator and evaluate energy delivery strategies for this application. Experiments in ex vivo and in vivo tissue were employed to verify simulation results. Simulations predicted enhanced heating performance of the antenna using an angled monopole radiating element. Further, simulations indicate that while the endoscopic cap attenuated electric fields in tissue, it also enhanced surface cooling of tissue, increasing the likelihood of preserving mucosal tissue. Experiments in ex vivo tissue indicated the feasibility of sealing veins with 77 W microwave power delivered for 30 s. In vivo experiments demonstrated the ability to seal veins, while preserving surface tissue. This study demonstrated the technical feasibility of microwave thermal ablation for treating esophageal varices using a 2.45 GHz water-cooled directional microwave applicator.
Collapse
Affiliation(s)
- Jan Sebek
- Department of Electrical and Computer Engineering, Kansas State University, Manhattan, KS 66506; Department of Circuit Theory, Faculty of Electrical Engineering, Czech Technical University in Prague, Technicka 2, Praha 6 166 27, Czech Republic e-mail:
| | - Sergio Curto
- Department of Electrical and Computer Engineering, Kansas State University, Manhattan, KS 66506 e-mail:
| | - Jimmy Eaton-Evans
- School of Engineering and Informatics, NUIG, Galway H91 TK33, Ireland e-mail:
| | | | - Giuseppe Ruvio
- School of Engineering and Informatics, NUIG, Galway H91 TK33, Ireland e-mail:
| | - Chanran Ganta
- Department of Diagnostic Medicine and Pathobiology, Kansas State University, 1800 Denison Avenue, Manhattan, KS 66506 e-mail:
| | - Warren Beard
- Department of Clinical Sciences, Kansas State University, 1800 Denison Avenue, Manhattan, KS 66506 e-mail:
| | - Navtej Buttar
- Division of Gastroenterology and Hepatology, Mayo Clinic, 200 1st Street SW, Rochester, MN 55905 e-mail:
| | - Louis Wong Kee Song
- Division of Gastroenterology and Hepatology, Mayo Clinic, 200 1st Street SW, Rochester, MN 55905 e-mail:
| | - Punit Prakash
- Department of Electrical and Computer Engineering, Kansas State University, Manhattan, KS 66506 e-mail:
| |
Collapse
|
20
|
Ryan TP, Brace CL. Interstitial microwave treatment for cancer: historical basis and current techniques in antenna design and performance. Int J Hyperthermia 2016; 33:3-14. [DOI: 10.1080/02656736.2016.1214884] [Citation(s) in RCA: 27] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/11/2023] Open
Affiliation(s)
| | - Christopher L. Brace
- Departments of Radiology and Biomedical Engineering, University of Wisconsin, Madison, WI, USA
| |
Collapse
|
21
|
Lopresto V, Pinto R, Farina L, Cavagnaro M. Treatment planning in microwave thermal ablation: clinical gaps and recent research advances. Int J Hyperthermia 2016; 33:83-100. [PMID: 27431328 DOI: 10.1080/02656736.2016.1214883] [Citation(s) in RCA: 47] [Impact Index Per Article: 5.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/16/2023] Open
Abstract
Microwave thermal ablation (MTA) is a minimally invasive therapeutic technique aimed at destroying pathologic tissues through a very high temperature increase induced by the absorption of an electromagnetic field at microwave (MW) frequencies. Open problems, which are delaying MTA applications in clinical practice, are mainly linked to the extremely high temperatures, up to 120 °C, reached by the tissue close to the antenna applicator, as well as to the ability of foreseeing and controlling the shape and dimension of the thermally ablated area. Recent research was devoted to the characterisation of dielectric, thermal and physical properties of tissue looking at their changes with the increasing temperature, looking for possible developments of reliable, automatic and personalised treatment planning. In this paper, a review of the recently obtained results as well as new unpublished data will be presented and discussed.
Collapse
Affiliation(s)
- V Lopresto
- a Division of Health Protection Technologies , Italian National Agency for New Technologies, Energy and Sustainable Economic Development (ENEA) , Rome , Italy
| | - R Pinto
- a Division of Health Protection Technologies , Italian National Agency for New Technologies, Energy and Sustainable Economic Development (ENEA) , Rome , Italy
| | - L Farina
- b Department of Information Engineering, Electronics and Telecommunications , Sapienza University of Rome , Rome , Italy
| | - M Cavagnaro
- b Department of Information Engineering, Electronics and Telecommunications , Sapienza University of Rome , Rome , Italy
| |
Collapse
|
22
|
Curto S, Taj-Eldin M, Fairchild D, Prakash P. Microwave ablation at 915 MHz vs 2.45 GHz: A theoretical and experimental investigation. Med Phys 2016; 42:6152-61. [PMID: 26520708 DOI: 10.1118/1.4931959] [Citation(s) in RCA: 35] [Impact Index Per Article: 3.9] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/31/2022] Open
Abstract
PURPOSE The relationship between microwave ablation system operating frequency and ablation performance is not currently well understood. The objective of this study was to comparatively assess the differences in microwave ablation at 915 MHz and 2.45 GHz. METHODS Analytical expressions for electromagnetic radiation from point sources were used to compare power deposition at the two frequencies of interest. A 3D electromagnetic-thermal bioheat transfer solver was implemented with the finite element method to characterize power deposition and thermal ablation with asymmetrical insulated dipole antennas (single-antenna and dual-antenna synchronous arrays). Simulation results were validated against experiments in ex vivo tissue. RESULTS Theoretical, computational, and experimental results indicated greater power deposition and larger diameter ablation zones when using a single insulated microwave antenna at 2.45 GHz; experimentally, 32±4.1 mm and 36.3±1.0 mm for 5 and 10 min, respectively, at 2.45 GHz, compared to 24±1.7 mm and 29.5±0.6 mm at 915 MHz, with 30 W forward power at the antenna input port. In experiments, faster heating was observed at locations 5 mm (0.91 vs 0.49 °C/s) and 10 mm (0.28 vs 0.15 °C/s) from the antenna operating at 2.45 GHz. Larger ablation zones were observed with dual-antenna arrays at 2.45 GHz; however, the differences were less pronounced than for single antennas. CONCLUSIONS Single- and dual-antenna arrays systems operating at 2.45 GHz yield larger ablation zone due to greater power deposition in proximity to the antenna, as well as greater role of thermal conduction.
Collapse
Affiliation(s)
- Sergio Curto
- Department of Electrical and Computer Engineering, Kansas State University, Manhattan, Kansas 66506
| | - Mohammed Taj-Eldin
- Department of Electrical and Computer Engineering, Kansas State University, Manhattan, Kansas 66506
| | - Dillon Fairchild
- Department of Electrical and Computer Engineering, Kansas State University, Manhattan, Kansas 66506
| | - Punit Prakash
- Department of Electrical and Computer Engineering, Kansas State University, Manhattan, Kansas 66506
| |
Collapse
|
23
|
Sawicki JF, Shea JD, Behdad N, Hagness SC. The impact of frequency on the performance of microwave ablation. Int J Hyperthermia 2016; 33:61-68. [DOI: 10.1080/02656736.2016.1207254] [Citation(s) in RCA: 16] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/21/2022] Open
Affiliation(s)
- James F. Sawicki
- Department of Electrical and Computer Engineering, University of Wisconsin, Madison, Wisconsin, USA
| | - Jacob D. Shea
- Department of Electrical and Computer Engineering, University of Wisconsin, Madison, Wisconsin, USA
| | - Nader Behdad
- Department of Electrical and Computer Engineering, University of Wisconsin, Madison, Wisconsin, USA
| | - Susan C. Hagness
- Department of Electrical and Computer Engineering, University of Wisconsin, Madison, Wisconsin, USA
| |
Collapse
|
24
|
Deshazer G, Prakash P, Merck D, Haemmerich D. Experimental measurement of microwave ablation heating pattern and comparison to computer simulations. Int J Hyperthermia 2016; 33:74-82. [PMID: 27431040 DOI: 10.1080/02656736.2016.1206630] [Citation(s) in RCA: 24] [Impact Index Per Article: 2.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/17/2022] Open
Abstract
INTRODUCTION For computational models of microwave ablation (MWA), knowledge of the antenna design is necessary, but the proprietary design of clinical applicators is often unknown. We characterised the specific absorption rate (SAR) during MWA experimentally and compared to a multi-physics simulation. METHODS An infrared (IR) camera was used to measure SAR during MWA within a split ex vivo liver model. Perseon Medical's short-tip (ST) or long-tip (LT) MWA antenna were placed on top of a tissue sample (n = 6), and microwave power (15 W) was applied for 6 min, while intermittently interrupting power. Tissue surface temperature was recorded via IR camera (3.3 fps, 320 × 240 resolution). SAR was calculated intermittently based on temperature slope before and after power interruption. Temperature and SAR data were compared to simulation results. RESULTS Experimentally measured SAR changed considerably once tissue temperatures exceeded 100 °C, contrary to simulation results. The ablation zone diameters were 1.28 cm and 1.30 ± 0.03 cm (transverse), and 2.10 cm and 2.66 ± -0.22 cm (axial), for simulation and experiment, respectively. The average difference in temperature between the simulation and experiment were 5.6 °C (ST) and 6.2 °C (LT). Dice coefficients for 1000 W/kg SAR iso-contour were 0.74 ± 0.01 (ST) and 0.77 (± 0.03) (LT), suggesting good agreement of SAR contours. CONCLUSION We experimentally demonstrated changes in SAR during MWA ablation, which were not present in simulation, suggesting inaccuracies in dielectric properties. The measured SAR may be used in simplified computer simulations to predict tissue temperature when the antenna geometry is unknown.
Collapse
Affiliation(s)
- Garron Deshazer
- a Department of Diagnostic Imaging , Rhode Island Hospital , Providence , Rhode Island , USA
| | - Punit Prakash
- b Department of Electrical and Computer Engineering , Kansas State University , Manhattan , Kansas , USA
| | - Derek Merck
- a Department of Diagnostic Imaging , Rhode Island Hospital , Providence , Rhode Island , USA
| | - Dieter Haemmerich
- c Department of Pediatrics , Medical University of South Carolina , Charleston , South Carolina , USA
| |
Collapse
|
25
|
Sebek J, Curto S, Bortel R, Prakash P. Analysis of minimally invasive directional antennas for microwave tissue ablation. Int J Hyperthermia 2016; 33:51-60. [DOI: 10.1080/02656736.2016.1195519] [Citation(s) in RCA: 19] [Impact Index Per Article: 2.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/03/2023] Open
Affiliation(s)
- Jan Sebek
- Department of Electrical and Computer Engineering, Kansas State University, Manhattan, Kansas, USA
- Department of Circuit Theory, Czech Technical University, Prague, Czech Republic
| | - Sergio Curto
- Department of Electrical and Computer Engineering, Kansas State University, Manhattan, Kansas, USA
| | - Radoslav Bortel
- Department of Circuit Theory, Czech Technical University, Prague, Czech Republic
| | - Punit Prakash
- Department of Electrical and Computer Engineering, Kansas State University, Manhattan, Kansas, USA
| |
Collapse
|
26
|
Sebek J, Albin N, Bortel R, Natarajan B, Prakash P. Sensitivity of microwave ablation models to tissue biophysical properties: A first step toward probabilistic modeling and treatment planning. Med Phys 2016; 43:2649. [DOI: 10.1118/1.4947482] [Citation(s) in RCA: 46] [Impact Index Per Article: 5.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/22/2022] Open
|
27
|
Deshazer G, Merck D, Hagmann M, Dupuy DE, Prakash P. Physical modeling of microwave ablation zone clinical margin variance. Med Phys 2016; 43:1764. [DOI: 10.1118/1.4942980] [Citation(s) in RCA: 30] [Impact Index Per Article: 3.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/22/2022] Open
|