1
|
Venet M, Malik A, Gold S, Zhang N, Gopaul J, Dauz J, Yazaki K, Ponzoni M, Coles JG, Maynes JT, Sun M, Howell A, Chaturvedi R, Mertens L, Mroczek D, Uike K, Baranger J, Friedberg MK, Villemain O. Impact of Right Ventricular Pressure Overload on Myocardial Stiffness Assessed by Natural Wave Imaging. JACC Cardiovasc Imaging 2025; 18:211-225. [PMID: 39177563 DOI: 10.1016/j.jcmg.2024.06.020] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 12/22/2023] [Revised: 05/29/2024] [Accepted: 06/28/2024] [Indexed: 08/24/2024]
Abstract
BACKGROUND Right ventricular (RV) hemodynamic performance determines the prognosis of patients with RV pressure overload. Using ultrafast ultrasound, natural wave velocity (NWV) induced by cardiac valve closure was proposed as a new surrogate to quantify myocardial stiffness. OBJECTIVES This study aimed to assess RV NWV in rodent models and children with RV pressure overload vs control subjects and to correlate NWV with RV hemodynamic parameters. METHODS Six-week-old rats were randomized to pulmonary artery banding (n = 6), Sugen hypoxia-induced pulmonary arterial hypertension (n = 7), or sham (n = 6) groups. They underwent natural wave imaging, echocardiography, and hemodynamic assessment at baseline and 6 weeks postoperatively. The authors analyzed NWV after tricuspid and after pulmonary valve closure (TVC and PVC, respectively). Conductance catheters were used to generate pressure-volume loops. In parallel, the authors prospectively recruited 14 children (7 RV pressure overload; 7 age-matched control subjects) and compared RV NWV with echocardiographic and invasive hemodynamic parameters. RESULTS NWV significantly increased in RV pressure overload rat models (4.99 ± 0.27 m/s after TVC and 5.03 ± 0.32 m/s after PVC in pulmonary artery banding at 6 weeks; 4.89 ± 0.26 m/s after TVC and 4.84 ± 0.30 m/s after PVC in Sugen hypoxia at 6 weeks) compared with control subjects (2.83 ± 0.15 m/s after TVC and 2.72 ± 0.34 m/s after PVC). NWV after TVC correlated with both systolic and diastolic parameters including RV dP/dtmax (r = 0.75; P < 0.005) and RV Ees (r = 0.81; P < 0.005). NWV after PVC correlated with both diastolic and systolic parameters and notably with RV end-diastolic pressure (r = 0.65; P < 0.01). In children, NWV after both right valves closure in RV pressure overload were higher than in healthy volunteers (P < 0.01). NWV after PVC correlated with RV E/E' (r = 0.81; P = 0.008) and with RV chamber stiffness (r = 0.97; P = 0.03). CONCLUSIONS Both RV early-systolic and early-diastolic myocardial stiffness show significant increase in response to pressure overload. Based on physiology and our observations, early-systolic myocardial stiffness may reflect contractility, whereas early-diastolic myocardial stiffness might be indicative of diastolic function.
Collapse
Affiliation(s)
- Maelys Venet
- Department of Cardiology, The Labatt Family Heart Centre, The Hospital for Sick Children, Toronto, Ontario, Canada; Bordeaux University Hospital, Department of Pediatric and Adult Congenital Cardiology, Pessac, France; Electrophysiology and Heart Modeling Institute, Institut Hospital-Universitaire Liryc, Fondation Bordeaux Université, Bordeaux, France.
| | - Aimen Malik
- Department of Cardiology, The Labatt Family Heart Centre, The Hospital for Sick Children, Toronto, Ontario, Canada
| | - Samantha Gold
- Department of Cardiology, The Labatt Family Heart Centre, The Hospital for Sick Children, Toronto, Ontario, Canada
| | - Naiyuan Zhang
- Department of Cardiology, The Labatt Family Heart Centre, The Hospital for Sick Children, Toronto, Ontario, Canada
| | - Josh Gopaul
- Department of Cardiology, The Labatt Family Heart Centre, The Hospital for Sick Children, Toronto, Ontario, Canada
| | - John Dauz
- Department of Cardiology, The Labatt Family Heart Centre, The Hospital for Sick Children, Toronto, Ontario, Canada
| | - Kana Yazaki
- Department of Cardiology, The Labatt Family Heart Centre, The Hospital for Sick Children, Toronto, Ontario, Canada
| | - Matteo Ponzoni
- Department of Cardiovascular Surgery, The Labatt Family Heart Centre, The Hospital for Sick Children, Toronto, Ontario, Canada
| | - John G Coles
- Department of Cardiovascular Surgery, The Labatt Family Heart Centre, The Hospital for Sick Children, Toronto, Ontario, Canada
| | - Jason T Maynes
- Department of Anesthesia and Pain Medicine, The Hospital for Sick Children, Toronto, Ontario, Canada
| | - Mei Sun
- Department of Cardiology, The Labatt Family Heart Centre, The Hospital for Sick Children, Toronto, Ontario, Canada
| | - Alison Howell
- Department of Cardiology, The Labatt Family Heart Centre, The Hospital for Sick Children, Toronto, Ontario, Canada
| | - Rajiv Chaturvedi
- Department of Cardiology, The Labatt Family Heart Centre, The Hospital for Sick Children, Toronto, Ontario, Canada
| | - Luc Mertens
- Department of Cardiology, The Labatt Family Heart Centre, The Hospital for Sick Children, Toronto, Ontario, Canada
| | - Dariusz Mroczek
- Department of Cardiology, The Labatt Family Heart Centre, The Hospital for Sick Children, Toronto, Ontario, Canada
| | - Kiyoshi Uike
- Department of Cardiology, The Labatt Family Heart Centre, The Hospital for Sick Children, Toronto, Ontario, Canada
| | - Jerome Baranger
- Department of Cardiology, The Labatt Family Heart Centre, The Hospital for Sick Children, Toronto, Ontario, Canada
| | - Mark K Friedberg
- Department of Cardiology, The Labatt Family Heart Centre, The Hospital for Sick Children, Toronto, Ontario, Canada
| | - Olivier Villemain
- Department of Cardiology, The Labatt Family Heart Centre, The Hospital for Sick Children, Toronto, Ontario, Canada; Bordeaux University Hospital, Department of Pediatric and Adult Congenital Cardiology, Pessac, France; Electrophysiology and Heart Modeling Institute, Institut Hospital-Universitaire Liryc, Fondation Bordeaux Université, Bordeaux, France. https://twitter.com/Villemain_Team
| |
Collapse
|
2
|
Xing P, Perrot V, Dominguez-Vargas AU, Porée J, Quessy S, Dancause N, Provost J. 3D ultrasound localization microscopy of the nonhuman primate brain. EBioMedicine 2025; 111:105457. [PMID: 39708427 PMCID: PMC11730257 DOI: 10.1016/j.ebiom.2024.105457] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/10/2024] [Revised: 10/18/2024] [Accepted: 11/04/2024] [Indexed: 12/23/2024] Open
Abstract
BACKGROUND Haemodynamic changes occur in stroke and neurodegenerative diseases. Developing imaging techniques allowing the in vivo visualisation and quantification of cerebral blood flow would help better understand the underlying mechanism of these cerebrovascular diseases. METHODS 3D ultrasound localization microscopy (ULM) is a recently developed technology that can map the microvasculature of the brain at large depth and has been mainly used until now in rodents. In this study, we tested the feasibility of 3D ULM of the nonhuman primate (NHP) brain with a single 256-channel programmable ultrasound scanner. FINDINGS We achieved a highly resolved vascular map of the macaque brain at large depth (down to 3 cm) in presence of craniotomy and durectomy using an 8-MHz multiplexed matrix probe. We were able to distinguish vessels as small as 26.9 μm. We also demonstrated that transcranial imaging of the macaque brain at similar depth was feasible using a 3-MHz probe and achieved a resolution of 60 μm. INTERPRETATION This work paves the way to clinical applications of 3D ULM. In particular, transcranial 3D ULM in humans could become a tool for the non-invasive study and monitoring of the brain cerebrovascular changes occurring in neurological diseases. FUNDING This work was supported by the New Frontier in Research Fund (NFRFE-2022-00590), by the Canada Foundation for Innovation under grant 38095, by the Natural Sciences and Engineering Research Council of Canada (NSERC) under discovery grant RGPIN-2020-06786, by Brain Canada under grant PSG2019, and by the Canadian Institutes of Health Research (CIHR) under grant PJT-156047 and MPI-452530. Computing support was provided by the Digital Research Alliance of Canada.
Collapse
Affiliation(s)
- Paul Xing
- Department of Engineering Physics, Polytechnique Montréal, Montreal, Canada
| | - Vincent Perrot
- Department of Engineering Physics, Polytechnique Montréal, Montreal, Canada
| | | | - Jonathan Porée
- Department of Engineering Physics, Polytechnique Montréal, Montreal, Canada
| | - Stephan Quessy
- Département de Neurosciences, Faculté de Médecine, Université de Montréal, Montreal, Canada
| | - Numa Dancause
- Département de Neurosciences, Faculté de Médecine, Université de Montréal, Montreal, Canada; Centre Interdisciplinaire de Recherche sur le Cerveau et l'apprentissage (CIRCA), Université de Montréal, Montreal, Canada
| | - Jean Provost
- Department of Engineering Physics, Polytechnique Montréal, Montreal, Canada; Montreal Heart Institute, Montreal, Canada.
| |
Collapse
|
3
|
Caudoux M, Demeulenaere O, Poree J, Sauvage J, Mateo P, Ghaleh B, Flesch M, Ferin G, Tanter M, Deffieux T, Papadacci C, Pernot M. Curved Toroidal Row Column Addressed Transducer for 3D Ultrafast Ultrasound Imaging. IEEE TRANSACTIONS ON MEDICAL IMAGING 2024; 43:3279-3291. [PMID: 38640053 DOI: 10.1109/tmi.2024.3391689] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 04/21/2024]
Abstract
3D Imaging of the human heart at high frame rate is of major interest for various clinical applications. Electronic complexity and cost has prevented the dissemination of 3D ultrafast imaging into the clinic. Row column addressed (RCA) transducers provide volumetric imaging at ultrafast frame rate by using a low electronic channel count, but current models are ill-suited for transthoracic cardiac imaging due to field-of-view limitations. In this study, we proposed a mechanically curved RCA with an aperture adapted for transthoracic cardiac imaging ( 24×16 mm2). The RCA has a toroidal curved surface of 96 elements along columns (curvature radius rC = 4.47 cm) and 64 elements along rows (curvature radius rR = 3 cm). We implemented delay and sum beamforming with an analytical calculation of the propagation of a toroidal wave which was validated using simulations (Field II). The imaging performance was evaluated on a calibrated phantom. Experimental 3D imaging was achieved up to 12 cm deep with a total angular aperture of 30° for both lateral dimensions. The Contrast-to-Noise ratio increased by 12 dB from 2 to 128 virtual sources. Then, 3D Ultrasound Localization Microscopy (ULM) was characterized in a sub-wavelength tube diameter. Finally, 3D ULM was demonstrated on a perfused ex-vivo swine heart to image the coronary microcirculation.
Collapse
|
4
|
Dong Z, Lok UW, Lowerison MR, Huang C, Chen S, Song P. Three-Dimensional Shear Wave Elastography Using Acoustic Radiation Force and a 2-D Row-Column Addressing (RCA) Array. IEEE TRANSACTIONS ON ULTRASONICS, FERROELECTRICS, AND FREQUENCY CONTROL 2024; 71:448-458. [PMID: 38363671 DOI: 10.1109/tuffc.2024.3366540] [Citation(s) in RCA: 5] [Impact Index Per Article: 5.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 02/18/2024]
Abstract
Acoustic radiation force (ARF)-based shear wave elastography (SWE) is a clinically available ultrasound imaging mode that noninvasively and quantitatively measures tissue stiffness. Current implementations of ARF-SWE are largely limited to 2-D imaging, which does not provide a robust estimation of heterogeneous tissue mechanical properties. Existing 3-D ARF-SWE solutions that are clinically available are based on wobbler probes, which cannot provide true 3-D shear wave motion detection. Although 3-D ARF-SWE based on 2-D matrix arrays have been previously demonstrated, they do not provide a practical solution because of the need for a high channel-count ultrasound system (e.g., 1024-channel) to provide adequate volume rates and the delicate circuitries (e.g., multiplexers) that are vulnerable to the long-duration "push" pulses. To address these issues, here we propose a new 3-D ARF-SWE method based on the 2-D row-column addressing (RCA) array which has a much lower element count (e.g., 256), provides an ultrafast imaging volume rate (e.g., 2000 Hz), and can withstand the push pulses. In this study, we combined the comb-push shear elastography (CUSE) technique with 2-D RCA for enhanced SWE imaging field-of-view (FOV). In vitro phantom studies demonstrated that the proposed method had robust 3-D SWE performance in both homogenous and inclusion phantoms. An in vivo study on a breast cancer patient showed that the proposed method could reconstruct 3-D elasticity maps of the breast lesion, which was validated using a commercial ultrasound scanner. These results demonstrate strong potential for the proposed method to provide a viable and practical solution for clinical 3-D ARF-SWE.
Collapse
|
5
|
Caenen A, Bézy S, Pernot M, Nightingale KR, Vos HJ, Voigt JU, Segers P, D'hooge J. Ultrasound Shear Wave Elastography in Cardiology. JACC Cardiovasc Imaging 2024; 17:314-329. [PMID: 38448131 DOI: 10.1016/j.jcmg.2023.12.007] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 12/23/2022] [Revised: 11/14/2023] [Accepted: 12/07/2023] [Indexed: 03/08/2024]
Abstract
The advent of high-frame rate imaging in ultrasound allowed the development of shear wave elastography as a noninvasive alternative for myocardial stiffness assessment. It measures mechanical waves propagating along the cardiac wall with speeds that are related to stiffness. The use of cardiac shear wave elastography in clinical studies is increasing, but a proper understanding of the different factors that affect wave propagation is required to correctly interpret results because of the heart's thin-walled geometry and intricate material properties. The aims of this review are to give an overview of the general concepts in cardiac shear wave elastography and to discuss in depth the effects of age, hemodynamic loading, cardiac morphology, fiber architecture, contractility, viscoelasticity, and system-dependent factors on the measurements, with a focus on clinical application. It also describes how these factors should be considered during acquisition, analysis, and reporting to ensure an accurate, robust, and reproducible measurement of the shear wave.
Collapse
Affiliation(s)
- Annette Caenen
- Institute for Biomedical Engineering and Technology, Ghent University, Ghent, Belgium; Department of Cardiovascular Sciences, University of Leuven, Leuven, Belgium; Department of Cardiology, Erasmus MC University Medical Center, Rotterdam, the Netherlands
| | - Stéphanie Bézy
- Department of Cardiovascular Sciences, University of Leuven, Leuven, Belgium
| | - Mathieu Pernot
- Physics for Medicine, INSERM, CNRS, ESPCI, PSL University, Paris, France
| | | | - Hendrik J Vos
- Department of Cardiology, Erasmus MC University Medical Center, Rotterdam, the Netherlands
| | - Jens-Uwe Voigt
- Department of Cardiovascular Sciences, University of Leuven, Leuven, Belgium; Department of Cardiovascular Diseases, University Hospitals Leuven, Leuven, Belgium.
| | - Patrick Segers
- Institute for Biomedical Engineering and Technology, Ghent University, Ghent, Belgium
| | - Jan D'hooge
- Department of Cardiovascular Sciences, University of Leuven, Leuven, Belgium
| |
Collapse
|
6
|
Malik A, Villalobos Lizardi JC, Baranger J, Venet M, Pernot M, Mital S, Nguyen MB, Chaturvedi R, Mertens L, Villemain O. Comparison Between Acoustic Radiation Force-Induced and Natural Wave Velocities for Myocardial Stiffness Assessment in Hypertrophic Cardiomyopathy. JACC Cardiovasc Imaging 2024; 17:223-225. [PMID: 37737792 DOI: 10.1016/j.jcmg.2023.07.015] [Citation(s) in RCA: 4] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 02/14/2023] [Revised: 07/24/2023] [Accepted: 07/26/2023] [Indexed: 09/23/2023]
|
7
|
Petrescu A, Voigt JU. [Echocardiography with high frame rates in the clinical practice : Principles, applications and perspectives]. Herz 2023; 48:339-351. [PMID: 37530782 DOI: 10.1007/s00059-023-05199-x] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Accepted: 06/16/2023] [Indexed: 08/03/2023]
Abstract
Continuous developments in cardiovascular imaging, software and hardware have led to technological advancements that open new ways for assessing myocardial mechanics, hemodynamics, and function. Through new scan modalities, echocardiographic scanners can nowadays achieve very high frame rates up to 5000 frames s-1 which enables a wide variety of new applications, including shear wave elastography, ultrafast speckle tracking, the visualization of intracardiac blood flow and myocardial perfusion imaging. This review provides an overview of these advances and demonstrates possible applications and their potential added value in the clinical practice.
Collapse
Affiliation(s)
- Aniela Petrescu
- Abteilung für Kardiologie, Universitätsmedizin Mainz, Mainz, Deutschland
| | - Jens-Uwe Voigt
- Department of Cardiology, University Hospital Leuven, University of Leuven, Herestraat 49, 3000, Leuven, Belgien.
| |
Collapse
|
8
|
Jin FQ, Kakkad V, Bradway DP, LeFevre M, Kisslo J, Khouri MG, Trahey GE. Evaluation of Myocardial Stiffness in Cardiac Amyloidosis Using Acoustic Radiation Force Impulse and Natural Shear Wave Imaging. ULTRASOUND IN MEDICINE & BIOLOGY 2023; 49:1719-1727. [PMID: 37149428 PMCID: PMC10330400 DOI: 10.1016/j.ultrasmedbio.2023.03.016] [Citation(s) in RCA: 7] [Impact Index Per Article: 3.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 12/01/2022] [Revised: 03/20/2023] [Accepted: 03/23/2023] [Indexed: 05/08/2023]
Abstract
OBJECTIVE Increased myocardial stiffness (MS) is an important hallmark of cardiac amyloidosis (CA) caused by myocardial amyloid deposition. Standard echocardiography metrics assess MS indirectly via downstream effects of cardiac stiffening. The ultrasound elastography methods acoustic radiation force impulse (ARFI) and natural shear wave (NSW) imaging assess MS more directly. METHODS This study compared MS in 12 healthy volunteers and 13 patients with confirmed CA using ARFI and NSW imaging. Parasternal long-axis acquisitions of the interventricular septum were obtained using a modified Acuson Sequoia scanner and a 5V1 transducer. ARFI-induced displacements were measured through the cardiac cycle, and ratios of diastolic-over-systolic displacement were calculated. NSW speeds from aortic valve closure were extracted from echocardiography-tracked displacement data. RESULTS ARFI stiffness ratios were significantly lower in CA patients than controls (mean ± standard deviation: 1.47 ± 0.27 vs. 2.10 ± 0.47, p < 0.001), and NSW speeds were significantly higher in CA patients than controls (5.58 ± 1.10 m/s vs. 3.79 ± 1.10 m/s, p < 0.001). A linear combination of the two metrics exhibited greater diagnostic potential than either metric alone (area under the curve = 0.97 vs. 0.89 and 0.88). CONCLUSION MS was measured to be significantly higher in CA patients using both ARFI and NSW imaging. Together, these methods have potential utility to aid in clinical diagnosis of diastolic dysfunction and infiltrative cardiomyopathies.
Collapse
Affiliation(s)
- Felix Q Jin
- Department of Biomedical Engineering, Duke University, Durham, North Carolina, USA
| | - Vaibhav Kakkad
- Department of Biomedical Engineering, Duke University, Durham, North Carolina, USA.
| | - David P Bradway
- Department of Biomedical Engineering, Duke University, Durham, North Carolina, USA
| | - Melissa LeFevre
- Department of Cardiology, Duke University Medical Center, Durham, North Carolina, USA
| | - Joseph Kisslo
- Department of Cardiology, Duke University Medical Center, Durham, North Carolina, USA
| | - Michel G Khouri
- Department of Cardiology, Duke University Medical Center, Durham, North Carolina, USA
| | - Gregg E Trahey
- Department of Biomedical Engineering, Duke University, Durham, North Carolina, USA; Department of Radiology, Duke University Medical Center, Durham, North Carolina, USA
| |
Collapse
|
9
|
Li H, Bhatt M, Qu Z, Zhang S, Hartel MC, Khademhosseini A, Cloutier G. Deep learning in ultrasound elastography imaging: A review. Med Phys 2022; 49:5993-6018. [PMID: 35842833 DOI: 10.1002/mp.15856] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/07/2021] [Revised: 02/04/2022] [Accepted: 07/06/2022] [Indexed: 11/11/2022] Open
Abstract
It is known that changes in the mechanical properties of tissues are associated with the onset and progression of certain diseases. Ultrasound elastography is a technique to characterize tissue stiffness using ultrasound imaging either by measuring tissue strain using quasi-static elastography or natural organ pulsation elastography, or by tracing a propagated shear wave induced by a source or a natural vibration using dynamic elastography. In recent years, deep learning has begun to emerge in ultrasound elastography research. In this review, several common deep learning frameworks in the computer vision community, such as multilayer perceptron, convolutional neural network, and recurrent neural network are described. Then, recent advances in ultrasound elastography using such deep learning techniques are revisited in terms of algorithm development and clinical diagnosis. Finally, the current challenges and future developments of deep learning in ultrasound elastography are prospected. This article is protected by copyright. All rights reserved.
Collapse
Affiliation(s)
- Hongliang Li
- Laboratory of Biorheology and Medical Ultrasonics, University of Montreal Hospital Research Center, Montréal, Québec, Canada.,Institute of Biomedical Engineering, University of Montreal, Montréal, Québec, Canada
| | - Manish Bhatt
- Laboratory of Biorheology and Medical Ultrasonics, University of Montreal Hospital Research Center, Montréal, Québec, Canada
| | - Zhen Qu
- Laboratory of Biorheology and Medical Ultrasonics, University of Montreal Hospital Research Center, Montréal, Québec, Canada
| | - Shiming Zhang
- California Nanosystems Institute, University of California, Los Angeles, California, USA
| | - Martin C Hartel
- California Nanosystems Institute, University of California, Los Angeles, California, USA
| | - Ali Khademhosseini
- California Nanosystems Institute, University of California, Los Angeles, California, USA
| | - Guy Cloutier
- Laboratory of Biorheology and Medical Ultrasonics, University of Montreal Hospital Research Center, Montréal, Québec, Canada.,Institute of Biomedical Engineering, University of Montreal, Montréal, Québec, Canada.,Department of Radiology, Radio-Oncology and Nuclear Medicine, University of Montreal, Montréal, Québec, Canada
| |
Collapse
|
10
|
Image Human Thorax Using Ultrasound Traveltime Tomography with Supervised Descent Method. APPLIED SCIENCES-BASEL 2022. [DOI: 10.3390/app12136763] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/16/2022]
Abstract
The change of acoustic velocity in the human thorax reflects the functional status of the respiratory system. Imaging the thorax’s acoustic velocity distribution can be used to monitor the respiratory system. In this paper, the feasibility of imaging the human thorax using ultrasound traveltime tomography with a supervised descent method (SDM) is studied. The forward modeling is computed using the shortest path ray tracing (SPR) method. The training model is composed of homogeneous acoustic velocity background and a high-velocity rectangular block moving in the domain of interest (DoI). The average descent direction is learned from the training set. Numerical experiments are conducted to verify the method’s feasibility. Normal thorax model experiment proves that SDM traveltime tomography can efficiently reconstruct thorax acoustic velocity distribution. Numerical experiments based on synthetic thorax model of pleural effusion and pneumothorax show that SDM traveltime tomography has good generalization ability and can detect the change of acoustic velocity in human thorax. This method might be helpful for the diagnosis and evaluation of respiratory diseases.
Collapse
|
11
|
Facchin C, Certain A, Yoganathan T, Delacroix C, Garcia AA, Gaillard F, Lenoir O, Tharaux PL, Tavitian B, Balvay D. FIBER-ML, an Open-Source Supervised Machine Learning Tool for Quantification of Fibrosis in Tissue Sections. THE AMERICAN JOURNAL OF PATHOLOGY 2022; 192:783-793. [PMID: 35183511 DOI: 10.1016/j.ajpath.2022.01.013] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 11/09/2021] [Revised: 01/12/2022] [Accepted: 01/20/2022] [Indexed: 06/14/2023]
Abstract
Pathologic fibrosis is a major hallmark of tissue insult in many chronic diseases. Although the amount of fibrosis is recognized as a direct indicator of the extent of disease, there is no consentaneous method for its quantification in tissue sections. This study tested FIBER-ML, a semi-automated, open-source freeware that uses a machine-learning approach to quantify fibrosis automatically after a short user-controlled learning phase. Fibrosis was quantified in sirius red-stained tissue sections from two fibrogenic animal models: acute stress-induced cardiomyopathy in rats (Takotsubo syndrome-like) and HIV-induced nephropathy in mice (chronic kidney disease). The quantitative results of FIBER-ML software version 1.0 were compared with those of ImageJ in Takotsubo syndrome, and with those of inForm in chronic kidney disease. Intra- and inter-operator and inter-software correlation and agreement were assessed. All correlations were excellent (>0.95) in both data sets. The values of discriminatory power between the pathologic and healthy groups were <10-3 for data on Takotsubo syndrome and <10-4 for data on chronic kidney disease. Intra-operator agreement, assessed by intra-class coefficient correlation, was good (>0.8), while inter-operator and inter-software agreement ranged from moderate to good (>0.7). FIBER-ML performed in a fast and user-friendly manner, with reproducible and consistent quantification of fibrosis in tissue sections. It offers an open-source alternative to currently used software, including quality control and file management.
Collapse
Affiliation(s)
- Caterina Facchin
- Université de Paris, INSERM, Paris Cardiovascular Research Center, Paris, France.
| | - Anais Certain
- Université de Paris, INSERM, Paris Cardiovascular Research Center, Paris, France
| | - Thulaciga Yoganathan
- Université de Paris, INSERM, Paris Cardiovascular Research Center, Paris, France
| | - Clement Delacroix
- Université de Paris, INSERM, Paris Cardiovascular Research Center, Paris, France
| | | | - François Gaillard
- Université de Paris, INSERM, Paris Cardiovascular Research Center, Paris, France
| | - Olivia Lenoir
- Université de Paris, INSERM, Paris Cardiovascular Research Center, Paris, France
| | - Pierre-Louis Tharaux
- Université de Paris, INSERM, Paris Cardiovascular Research Center, Paris, France
| | - Bertrand Tavitian
- Université de Paris, INSERM, Paris Cardiovascular Research Center, Paris, France; Department of Radiology, Assistance Publique-Hôpitaux de Paris, Hopital Européen Georges Pompidou, Paris, France
| | - Daniel Balvay
- Université de Paris, INSERM, Paris Cardiovascular Research Center, Paris, France; Department of Radiology, Assistance Publique-Hôpitaux de Paris, Hopital Européen Georges Pompidou, Paris, France.
| |
Collapse
|
12
|
Demeulenaere O, Bertolo A, Pezet S, Ialy-Radio N, Osmanski B, Papadacci C, Tanter M, Deffieux T, Pernot M. In vivo whole brain microvascular imaging in mice using transcranial 3D Ultrasound Localization Microscopy. EBioMedicine 2022; 79:103995. [PMID: 35460988 PMCID: PMC9048085 DOI: 10.1016/j.ebiom.2022.103995] [Citation(s) in RCA: 47] [Impact Index Per Article: 15.7] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/19/2022] [Revised: 03/25/2022] [Accepted: 03/25/2022] [Indexed: 11/24/2022] Open
Abstract
Background Non-invasive high-resolution imaging of the cerebral vascular anatomy and function is key for the study of intracranial aneurysms, stenosis, arteriovenous malformations, and stroke, but also neurological pathologies, such as degenerative diseases. Direct visualization of the microvascular networks in the whole brain remains however challenging in vivo. Methods In this work, we performed 3D ultrafast ultrasound localization microscopy (ULM) using a 2D ultrasound matrix array and mapped the whole-brain microvasculature and flow at microscopic resolution in C57Bl6 mice in vivo. Findings We demonstrated that the mouse brain vasculature can be imaged directly through the intact skull at a spatial resolution of 20 µm and over the whole brain depth and at high temporal resolution (750 volumes.s−1). Individual microbubbles were tracked to estimate the flow velocities that ranged from 2 mm.s−1 in arterioles and venules up to 100 mm.s−1 in large vessels. The vascular maps were registered automatically with the Allen atlas in order to extract quantitative vascular parameters such as local flow rates and velocities in regions of interest. Interpretation We show the potential of 3D ULM to provide new insights into whole-brain vascular flow in mice models at unprecedented vascular scale for an in vivo technique. This technology is highly translational and has the potential to become a major tool for the clinical investigation of the cerebral microcirculation. Funding This study was supported by the European Research Council under the European Union's Seventh Framework Program (FP/2007-2013) / ERC Grant Agreement n° 311025 and by the Fondation Bettencourt-Schueller under the program “Physics for Medicine”. We acknowledge the ART (Technological Research Accelerator) biomedical ultrasound program of INSERM.
Collapse
Affiliation(s)
- Oscar Demeulenaere
- Physics for Medicine, ESPCI, Inserm, CNRS, Institute of Physics for Medicine Paris, PSL University, ESPCI Paris, 17 rue Moreau, Paris 75012, France
| | - Adrien Bertolo
- Physics for Medicine, ESPCI, Inserm, CNRS, Institute of Physics for Medicine Paris, PSL University, ESPCI Paris, 17 rue Moreau, Paris 75012, France; Iconeus, Paris 75014, France
| | - Sophie Pezet
- Physics for Medicine, ESPCI, Inserm, CNRS, Institute of Physics for Medicine Paris, PSL University, ESPCI Paris, 17 rue Moreau, Paris 75012, France
| | - Nathalie Ialy-Radio
- Physics for Medicine, ESPCI, Inserm, CNRS, Institute of Physics for Medicine Paris, PSL University, ESPCI Paris, 17 rue Moreau, Paris 75012, France
| | | | - Clément Papadacci
- Physics for Medicine, ESPCI, Inserm, CNRS, Institute of Physics for Medicine Paris, PSL University, ESPCI Paris, 17 rue Moreau, Paris 75012, France
| | - Mickael Tanter
- Physics for Medicine, ESPCI, Inserm, CNRS, Institute of Physics for Medicine Paris, PSL University, ESPCI Paris, 17 rue Moreau, Paris 75012, France
| | - Thomas Deffieux
- Physics for Medicine, ESPCI, Inserm, CNRS, Institute of Physics for Medicine Paris, PSL University, ESPCI Paris, 17 rue Moreau, Paris 75012, France
| | - Mathieu Pernot
- Physics for Medicine, ESPCI, Inserm, CNRS, Institute of Physics for Medicine Paris, PSL University, ESPCI Paris, 17 rue Moreau, Paris 75012, France.
| |
Collapse
|
13
|
Favre H, Pernot M, Tanter M, Papadacci C. Boosting transducer matrix sensitivity for 3D large field ultrasound localization microscopy using a multi-lens diffracting layer: a simulation study. Phys Med Biol 2022; 67. [DOI: 10.1088/1361-6560/ac5f72] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/23/2021] [Accepted: 03/21/2022] [Indexed: 11/12/2022]
Abstract
Abstract
Mapping blood microflows of the whole brain is crucial for early diagnosis of cerebral diseases. Ultrasound localization microscopy (ULM) was recently applied to map and quantify blood microflows in 2D in the brain of adult patients down to the micron scale. Whole brain 3D clinical ULM remains challenging due to the transcranial energy loss which significantly reduces the imaging sensitivity. Large aperture probes with a large surface can increase both resolution and sensitivity. However, a large active surface implies thousands of acoustic elements, with limited clinical translation. In this study, we investigate via simulations a new high-sensitive 3D imaging approach based on large diverging elements, combined with an adapted beamforming with corrected delay laws, to increase sensitivity. First, pressure fields from single elements with different sizes and shapes were simulated. High directivity was measured for curved element while maintaining high transmit pressure. Matrix arrays of 256 elements with a dimension of 10 × 10 cm with small (λ/2), large (4λ), and curved elements (4λ) were compared through point spread functions analysis. A large synthetic microvessel phantom filled with 100 microbubbles per frame was imaged using the matrix arrays in a transcranial configuration. 93% of the bubbles were detected with the proposed approach demonstrating that the multi-lens diffracting layer has a strong potential to enable 3D ULM over a large field of view through the bones.
Collapse
|
14
|
Coronary Flow Assessment Using 3-Dimensional Ultrafast Ultrasound Localization Microscopy. JACC: CARDIOVASCULAR IMAGING 2022; 15:1193-1208. [DOI: 10.1016/j.jcmg.2022.02.008] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Received: 08/02/2021] [Revised: 01/24/2022] [Accepted: 02/17/2022] [Indexed: 11/23/2022]
|
15
|
Bae S, Kim BH, Alizad A, Fatemi M, Song TK. Experimental Study of Aperiodic Plane Wave Imaging for Ultrafast 3-D Ultrasound Imaging. IEEE Trans Biomed Eng 2022; 69:2679-2690. [PMID: 35180073 PMCID: PMC9620471 DOI: 10.1109/tbme.2022.3152212] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/08/2022]
Abstract
OBJECTIVE Although plane wave imaging (PWI) with multiple plane waves (PWs) steered at different angles enables ultrafast three-dimensional (3-D) ultrasonic imaging, there is still a challenging tradeoff between image quality and frame rate. To address this challenge, we recently proposed the aperiodic PWI (APWI) with mathematical analysis and simulation study. In this paper, we demonstrate the feasibility of APWI and evaluate the performance with phantom and in vivo experiments. METHODS APWI with a concentric ring angle pattern (APWI-C) and APWI with a sunflower pattern (APWI-S) are evaluated. For experimental verification of the methods, the experimental results are compared with simulation results in terms of the mainlobe-to-sidelobe ratio. In addition, the performance of APWI is compared with that of conventional PWI by using a commercial phantom. To examine the potential for clinical use of APWI, a gallstone-mimicking phantom study and an in vivo carotid artery experiment are also conducted. RESULTS In the phantom study, the APWI methods provide a contrast ratio approximately 23 dB higher than that of PWI. In a gallstone mimicking experiment, the proposed methods yield 3-D rendered stone images more similar to the real stones than PWI. In the in vivo carotid artery images, APWI reduces the clutter artifacts inside the artery. CONCLUSION Phantom and in vivo studies show that the APWI enhances the contrast without compromising the spatial resolution and frame rate. SIGNIFICANCE This study experimentally demonstrates the feasibility and advantage of APWI for ultrafast 3-D ultrasonic imaging.
Collapse
|
16
|
Harbo MB, Stokke MK, Sjaastad I, Espe EKS. One step closer to myocardial physiology: From PV loop analysis to state-of-the-art myocardial imaging. Acta Physiol (Oxf) 2022; 234:e13759. [PMID: 34978759 DOI: 10.1111/apha.13759] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/16/2021] [Revised: 12/14/2021] [Accepted: 01/01/2022] [Indexed: 11/29/2022]
Abstract
Recent advances in cardiac imaging have revitalized the assessment of fundamental physiological concepts. In the field of cardiac physiology, invasive measurements with pressure-volume (PV) loops have served as the gold standard methodology for the characterization of left ventricular (LV) function. From PV loop data, fundamental aspects of LV chamber function are derived such as work, efficiency, stiffness and contractility. However, the parametrization of these aspects is limited because of the need for invasive procedures. Through the utilization of recent advances in echocardiography, magnetic resonance imaging and positron emission tomography, it has become increasingly feasible to quantify these fundamental aspects of LV function non-invasively. Importantly, state-of-the-art imaging technology enables direct assessment of myocardial performance, thereby extending functional assessment from the net function of the LV chamber, as is done with PV loops, to the myocardium itself. With a strong coupling to underlying myocardial physiology, imaging measurements of myocardial work, efficiency, stiffness and contractility could represent the next generation of functional parameters. The purpose of this review is to discuss how the new imaging parameters of myocardial work, efficiency, stiffness and contractility can bring cardiac physiologists, researchers and clinicians alike one step closer to underlying myocardial physiology.
Collapse
Affiliation(s)
- Markus Borge Harbo
- Institute for Experimental Medical Research Oslo University Hospital and University of Oslo Oslo Norway
- K.G. Jebsen Center for Cardiac Research University of Oslo Oslo Norway
| | - Mathis Korseberg Stokke
- Institute for Experimental Medical Research Oslo University Hospital and University of Oslo Oslo Norway
- K.G. Jebsen Center for Cardiac Research University of Oslo Oslo Norway
- Department of Cardiology Oslo University Hospital Rikshospitalet Oslo Norway
| | - Ivar Sjaastad
- Institute for Experimental Medical Research Oslo University Hospital and University of Oslo Oslo Norway
- K.G. Jebsen Center for Cardiac Research University of Oslo Oslo Norway
| | - Emil Knut Stenersen Espe
- Institute for Experimental Medical Research Oslo University Hospital and University of Oslo Oslo Norway
- K.G. Jebsen Center for Cardiac Research University of Oslo Oslo Norway
| |
Collapse
|
17
|
Villalobos Lizardi JC, Baranger J, Nguyen MB, Asnacios A, Malik A, Lumens J, Mertens L, Friedberg MK, Simmons CA, Pernot M, Villemain O. A guide for assessment of myocardial stiffness in health and disease. NATURE CARDIOVASCULAR RESEARCH 2022; 1:8-22. [PMID: 39196108 DOI: 10.1038/s44161-021-00007-3] [Citation(s) in RCA: 31] [Impact Index Per Article: 10.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 05/25/2021] [Accepted: 11/10/2021] [Indexed: 08/29/2024]
Abstract
Myocardial stiffness is an intrinsic property of the myocardium that influences both diastolic and systolic cardiac function. Myocardial stiffness represents the resistance of this tissue to being deformed and depends on intracellular components of the cardiomyocyte, particularly the cytoskeleton, and on extracellular components, such as collagen fibers. Myocardial disease is associated with changes in myocardial stiffness, and its assessment is a key diagnostic marker of acute or chronic pathological myocardial disease with the potential to guide therapeutic decision-making. In this Review, we appraise the different techniques that can be used to estimate myocardial stiffness, evaluate their advantages and disadvantages, and discuss potential clinical applications.
Collapse
Affiliation(s)
- José Carlos Villalobos Lizardi
- Division of Cardiology, Department of Pediatrics, The Hospital for Sick Children, University of Toronto, Toronto, Ontario, Canada
| | - Jerome Baranger
- Division of Cardiology, Department of Pediatrics, The Hospital for Sick Children, University of Toronto, Toronto, Ontario, Canada
| | - Minh B Nguyen
- Division of Cardiology, Department of Pediatrics, The Hospital for Sick Children, University of Toronto, Toronto, Ontario, Canada
| | - Atef Asnacios
- Laboratoire Matière et Systèmes Complexes, CNRS UMR 7057, Université de Paris, Paris, France
| | - Aimen Malik
- Division of Cardiology, Department of Pediatrics, The Hospital for Sick Children, University of Toronto, Toronto, Ontario, Canada
| | - Joost Lumens
- Department of Biomedical Engineering, Cardiovascular Research Institute Maastricht (CARIM), Maastricht University, Maastricht, the Netherlands
| | - Luc Mertens
- Division of Cardiology, Department of Pediatrics, The Hospital for Sick Children, University of Toronto, Toronto, Ontario, Canada
| | - Mark K Friedberg
- Division of Cardiology, Department of Pediatrics, The Hospital for Sick Children, University of Toronto, Toronto, Ontario, Canada
| | - Craig A Simmons
- Institute of Biomedical Engineering, University of Toronto, Toronto, Ontario, Canada
| | - Mathieu Pernot
- Physics for Medicine Paris, INSERM U1273, ESPCI Paris, CNRS UMR 8063, PSL Research University, Paris, France
| | - Olivier Villemain
- Division of Cardiology, Department of Pediatrics, The Hospital for Sick Children, University of Toronto, Toronto, Ontario, Canada.
| |
Collapse
|
18
|
Caenen A, Pernot M, Nightingale KR, Voigt JU, Vos HJ, Segers P, D'hooge J. Assessing cardiac stiffness using ultrasound shear wave elastography. Phys Med Biol 2021; 67. [PMID: 34874312 DOI: 10.1088/1361-6560/ac404d] [Citation(s) in RCA: 19] [Impact Index Per Article: 4.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/24/2021] [Accepted: 12/06/2021] [Indexed: 11/11/2022]
Abstract
Shear wave elastography offers a new dimension to echocardiography: it measures myocardial stiffness. Therefore, it could provide additional insights into the pathophysiology of cardiac diseases affecting myocardial stiffness and potentially improve diagnosis or guide patient treatment. The technique detects fast mechanical waves on the heart wall with high frame rate echography, and converts their propagation velocity into a stiffness value. A proper interpretation of shear wave data is required as the shear wave interacts with the intrinsic, yet dynamically changing geometrical and material characteristics of the heart under pressure. This dramatically alters the wave physics of the propagating wave, demanding adapted processing methods compared to other shear wave elastography applications as breast tumor and liver stiffness staging. Furthermore, several advanced analysis methods have been proposed to extract supplementary material features such as viscosity and anisotropy, potentially offering additional diagnostic value. This review explains the general mechanical concepts underlying cardiac shear wave elastography and provides an overview of the preclinical and clinical studies within the field. We also identify the mechanical and technical challenges ahead to make shear wave elastography a valuable tool for clinical practice.
Collapse
Affiliation(s)
- Annette Caenen
- Institute for Biomedical Engineering and Technology, Ghent University, Ghent, BELGIUM
| | - Mathieu Pernot
- INSERM U979 "Physics for medicine", ESPCI Paris, PSL Research University, CNRS UMR 7587, Institut Langevin, Paris, FRANCE
| | - Kathryn R Nightingale
- Department of Biomedical Engineering, Duke University, Durham, North Carolina, UNITED STATES
| | - Jens-Uwe Voigt
- Department of Cardiovascular Sciences, KU Leuven, Leuven, BELGIUM
| | - Hendrik J Vos
- Department of Biomedical Engineering, Erasmus MC, Rotterdam, Zuid-Holland, NETHERLANDS
| | - Patrick Segers
- Institute of Biomedical Engineering and Technology, Universiteit Gent, Gent, BELGIUM
| | - Jan D'hooge
- Department of Cardiovascular Sciences, KU Leuven, Leuven, BELGIUM
| |
Collapse
|
19
|
Pedreira O, Correia M, Chatelin S, Villemain O, Goudot G, Thiebaut S, Bassan G, Messas E, Tanter M, Papadacci C, Pernot M. Smart ultrasound device for non-invasive real-time myocardial stiffness quantification of the human heart. IEEE Trans Biomed Eng 2021; 69:42-52. [PMID: 34097602 DOI: 10.1109/tbme.2021.3087039] [Citation(s) in RCA: 9] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/08/2022]
Abstract
Quantitative assessment of myocardial stiffness is crucial to understand and evaluate cardiac biomechanics and function. Despite the recent progresses of ultrasonic shear wave elastography, quantitative evaluation of myocardial stiffness still remains a challenge because of strong elastic anisotropy. In this paper we introduce a smart ultrasound approach for non-invasive real-time quantification of shear wave velocity (SWV) and elastic fractional anisotropy (FA) in locally transverse isotropic elastic medium such as the myocardium. The approach relies on a simultaneous multidirectional evaluation of the SWV without a prior knowledge of the fiber orientation. We demonstrated that it can quantify accurately SWV in the range of 1.5 to 6 m/s in transverse isotropic medium (FA<0.7) using numerical simulations. Experimental validation was performed on calibrated phantoms and anisotropic ex vivo tissues. A mean absolute error of 0.22 m/s was found when compared to gold standard measurements. Finally, in vivo feasibility of myocardial anisotropic stiffness assessment was evaluated in four healthy volunteers on the antero-septo basal segment and on anterior free wall of the right ventricle (RV) in end-diastole. A mean longitudinal SWV of 1.08 0.20 m/s was measured on the RV wall and 1.74 0.51 m/s on the Septal wall with a good intra-volunteer reproducibility (0.18 m/s). This approach has the potential to become a clinical tool for the quantitative evaluation of myocardial stiffness and diastolic function.
Collapse
|
20
|
Petrescu A, D'hooge J, Voigt JU. Concepts and applications of ultrafast cardiac ultrasound imaging. Echocardiography 2021; 38:7-15. [PMID: 33471395 DOI: 10.1111/echo.14971] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/19/2020] [Accepted: 12/22/2020] [Indexed: 12/20/2022] Open
Abstract
The concept of ultrafast echocardiographic imaging has been around for decades. However, only recent progress in ultrasound machine hardware and computer technology allowed to apply this concept to echocardiography. High frame rate echocardiography can visualize phenomena that have never been captured before. It enables a wide variety of potential new applications, including shear wave imaging, speckle tracking, ultrafast Doppler imaging, and myocardial perfusion imaging. The principles of these applications and their potential clinical use will be presented in this manuscript.
Collapse
Affiliation(s)
- Aniela Petrescu
- Department of Cardiovascular Sciences, University of Leuven, Leuven, Belgium.,Department of Cardiology, Heart Valve Center, University Medical Center Mainz, Mainz, Germany
| | - Jan D'hooge
- Department of Cardiovascular Sciences, University of Leuven, Leuven, Belgium
| | - Jens-Uwe Voigt
- Department of Cardiovascular Sciences, University of Leuven, Leuven, Belgium.,Department of Cardiovascular Diseases, University Hospitals Leuven, Leuven, Belgium
| |
Collapse
|