1
|
Amitrano F, Coccia A, Pagano G, Biancardi A, Tombolini G, Marsico V, D’Addio G. Measuring Surface Electromyography with Textile Electrodes in a Smart Leg Sleeve. SENSORS (BASEL, SWITZERLAND) 2024; 24:2763. [PMID: 38732868 PMCID: PMC11086330 DOI: 10.3390/s24092763] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 03/15/2024] [Revised: 04/23/2024] [Accepted: 04/23/2024] [Indexed: 05/13/2024]
Abstract
This paper presents the design, development, and validation of a novel e-textile leg sleeve for non-invasive Surface Electromyography (sEMG) monitoring. This wearable device incorporates e-textile sensors for sEMG signal acquisition from the lower limb muscles, specifically the anterior tibialis and lateral gastrocnemius. Validation was conducted by performing a comparative study with eleven healthy volunteers to evaluate the performance of the e-textile sleeve in acquiring sEMG signals compared to traditional Ag/AgCl electrodes. The results demonstrated strong agreement between the e-textile and conventional methods in measuring descriptive metrics of the signals, including area, power, mean, and root mean square. The paired data t-test did not reveal any statistically significant differences, and the Bland-Altman analysis indicated negligible bias between the measures recorded using the two methods. In addition, this study evaluated the wearability and comfort of the e-textile sleeve using the Comfort Rating Scale (CRS). Overall, the scores confirmed that the proposed device is highly wearable and comfortable, highlighting its suitability for everyday use in patient care.
Collapse
Affiliation(s)
- Federica Amitrano
- Bioengineering Unit, Telese Terme Institute, Istituti Clinici Scientifici Maugeri IRCCS, 82037 Telese Terme, Italy; (F.A.); (G.D.)
| | - Armando Coccia
- Bioengineering Unit, Telese Terme Institute, Istituti Clinici Scientifici Maugeri IRCCS, 82037 Telese Terme, Italy; (F.A.); (G.D.)
| | - Gaetano Pagano
- Bioengineering Unit, Bari Institute, Istituti Clinici Scientifici Maugeri IRCCS, 70124 Bari, Italy;
| | - Arcangelo Biancardi
- Bioengineering Unit, Telese Terme Institute, Istituti Clinici Scientifici Maugeri IRCCS, 82037 Telese Terme, Italy; (F.A.); (G.D.)
| | | | - Vito Marsico
- Orthopaedics Unit, Bari Institute, Istituti Clinici Scientifici Maugeri IRCCS, 70124 Bari, Italy;
| | - Giovanni D’Addio
- Bioengineering Unit, Telese Terme Institute, Istituti Clinici Scientifici Maugeri IRCCS, 82037 Telese Terme, Italy; (F.A.); (G.D.)
| |
Collapse
|
2
|
Islam MR, Afroj S, Yin J, Novoselov KS, Chen J, Karim N. Advances in Printed Electronic Textiles. ADVANCED SCIENCE (WEINHEIM, BADEN-WURTTEMBERG, GERMANY) 2024; 11:e2304140. [PMID: 38009793 PMCID: PMC10853734 DOI: 10.1002/advs.202304140] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 06/22/2023] [Revised: 09/11/2023] [Indexed: 11/29/2023]
Abstract
Electronic textiles (e-textiles) have emerged as a revolutionary solution for personalized healthcare, enabling the continuous collection and communication of diverse physiological parameters when seamlessly integrated with the human body. Among various methods employed to create wearable e-textiles, printing offers unparalleled flexibility and comfort, seamlessly integrating wearables into garments. This has spurred growing research interest in printed e-textiles, due to their vast design versatility, material options, fabrication techniques, and wide-ranging applications. Here, a comprehensive overview of the crucial considerations in fabricating printed e-textiles is provided, encompassing the selection of conductive materials and substrates, as well as the essential pre- and post-treatments involved. Furthermore, the diverse printing techniques and the specific requirements are discussed, highlighting the advantages and limitations of each method. Additionally, the multitude of wearable applications made possible by printed e-textiles is explored, such as their integration as various sensors, supercapacitors, and heated garments. Finally, a forward-looking perspective is provided, discussing future prospects and emerging trends in the realm of printed wearable e-textiles. As advancements in materials science, printing technologies, and design innovation continue to unfold, the transformative potential of printed e-textiles in healthcare and beyond is poised to revolutionize the way wearable technology interacts and benefits.
Collapse
Affiliation(s)
- Md Rashedul Islam
- Centre for Print Research (CFPR)University of the West of EnglandFrenchay CampusBristolBS16 1QYUK
| | - Shaila Afroj
- Centre for Print Research (CFPR)University of the West of EnglandFrenchay CampusBristolBS16 1QYUK
| | - Junyi Yin
- Department of BioengineeringUniversity of CaliforniaLos AngelesCA90095USA
| | - Kostya S. Novoselov
- Institute for Functional Intelligent MaterialsDepartment of Materials Science and EngineeringNational University of SingaporeSingapore117575Singapore
| | - Jun Chen
- Department of BioengineeringUniversity of CaliforniaLos AngelesCA90095USA
| | - Nazmul Karim
- Centre for Print Research (CFPR)University of the West of EnglandFrenchay CampusBristolBS16 1QYUK
- Nottingham School of Art and DesignNottingham Trent UniversityShakespeare StreetNottinghamNG1 4GGUK
| |
Collapse
|
3
|
Murciego LP, Komolafe A, Peřinka N, Nunes-Matos H, Junker K, Díez AG, Lanceros-Méndez S, Torah R, Spaich EG, Dosen S. A Novel Screen-Printed Textile Interface for High-Density Electromyography Recording. SENSORS (BASEL, SWITZERLAND) 2023; 23:1113. [PMID: 36772153 PMCID: PMC9919117 DOI: 10.3390/s23031113] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 11/26/2022] [Revised: 01/06/2023] [Accepted: 01/09/2023] [Indexed: 06/18/2023]
Abstract
Recording electrical muscle activity using a dense matrix of detection points (high-density electromyography, EMG) is of interest in a range of different applications, from human-machine interfacing to rehabilitation and clinical assessment. The wider application of high-density EMG is, however, limited as the clinical interfaces are not convenient for practical use (e.g., require conductive gel/cream). In the present study, we describe a novel dry electrode (TEX) in which the matrix of sensing pads is screen printed on textile and then coated with a soft polymer to ensure good skin-electrode contact. To benchmark the novel solution, an identical electrode was produced using state-of-the-art technology (polyethylene terephthalate with hydrogel, PET) and a process that ensured a high-quality sample. The two electrodes were then compared in terms of signal quality as well as functional application. The tests showed that the signals collected using PET and TEX were characterised by similar spectra, magnitude, spatial distribution and signal-to-noise ratio. The electrodes were used by seven healthy subjects and an amputee participant to recognise seven hand gestures, leading to similar performance during offline analysis and online control. The comprehensive assessment, therefore, demonstrated that the proposed textile interface is an attractive solution for practical applications.
Collapse
Affiliation(s)
- Luis Pelaez Murciego
- Neurorehabilitation Systems, Department of Health Science and Technology, Faculty of Medicine, Aalborg University, 9260 Aalborg, Denmark
| | - Abiodun Komolafe
- School of Electronics and Computer Science, University of Southampton, Southampton SO17 1BJ, UK
| | - Nikola Peřinka
- BCMaterials, Basque Centre for Materials, Applications and Nanostructures, UPV/EHU Science Park, 48940 Leioa, Spain
| | - Helga Nunes-Matos
- School of Electronics and Computer Science, University of Southampton, Southampton SO17 1BJ, UK
| | | | - Ander García Díez
- BCMaterials, Basque Centre for Materials, Applications and Nanostructures, UPV/EHU Science Park, 48940 Leioa, Spain
| | - Senentxu Lanceros-Méndez
- BCMaterials, Basque Centre for Materials, Applications and Nanostructures, UPV/EHU Science Park, 48940 Leioa, Spain
- Ikerbasque, Basque Foundation for Science, 48009 Bilbao, Spain
| | - Russel Torah
- School of Electronics and Computer Science, University of Southampton, Southampton SO17 1BJ, UK
| | - Erika G. Spaich
- Neurorehabilitation Systems, Department of Health Science and Technology, Faculty of Medicine, Aalborg University, 9260 Aalborg, Denmark
| | - Strahinja Dosen
- Neurorehabilitation Systems, Department of Health Science and Technology, Faculty of Medicine, Aalborg University, 9260 Aalborg, Denmark
| |
Collapse
|
4
|
Mun E, Cho J. Review of Internet of Things-Based Artificial Intelligence Analysis Method through Real-Time Indoor Air Quality and Health Effect Monitoring: Focusing on Indoor Air Pollution That Are Harmful to the Respiratory Organ. Tuberc Respir Dis (Seoul) 2023; 86:23-32. [PMID: 36288738 PMCID: PMC9816487 DOI: 10.4046/trd.2022.0087] [Citation(s) in RCA: 1] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/07/2022] [Accepted: 10/26/2022] [Indexed: 12/23/2022] Open
Abstract
Everyone is aware that air and environmental pollutants are harmful to health. Among them, indoor air quality directly affects physical health, such as respiratory rather than outdoor air. However, studies that have examined the correlation between environmental and health information have been conducted with public data targeting large cohorts, and studies with real-time data analysis are insufficient. Therefore, this research explores the research with an indoor air quality monitoring (AQM) system based on developing environmental detection sensors and the internet of things to collect, monitor, and analyze environmental and health data from various data sources in real-time. It explores the usage of wearable devices for health monitoring systems. In addition, the availability of big data and artificial intelligence analysis and prediction has increased, investigating algorithmic studies for accurate prediction of hazardous environments and health impacts. Regarding health effects, techniques to prevent respiratory and related diseases were reviewed.
Collapse
Affiliation(s)
- EunMi Mun
- Department of Software Engineering, Jeonbuk National University, Jeonju, Republic of Korea
| | - Jaehyuk Cho
- Department of Software Engineering, Jeonbuk National University, Jeonju, Republic of Korea,Address for correspondence Jaehyuk Cho, Ph.D. Department of Software Engineering, Jeonbuk National University, 567 Baekje-daero, Deokjin-gu, Jeonju 54896, Republic of Korea Phone 82-63-270-4771 Fax 82-63-270-4767 E-mail
| |
Collapse
|
5
|
Zhang M, Guo N, Gao Q, Li H, Wang Z. Design, Characterization, and Performance of Woven Fabric Electrodes for Electrocardiogram Signal Monitoring. SENSORS 2022; 22:s22155472. [PMID: 35897976 PMCID: PMC9331634 DOI: 10.3390/s22155472] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 06/10/2022] [Revised: 07/16/2022] [Accepted: 07/18/2022] [Indexed: 11/20/2022]
Abstract
Conductive gel needs to be applied between the skin and standard medical electrodes when monitoring electrocardiogram (ECG) signals, but this can cause skin irritation, particularly during long-term monitoring. Fabric electrodes are flexible, breathable, and capable of sensing ECG signals without conductive gel. The objective of this study was to design and fabricate a circular fabric electrode using weaving technology. To optimize the woven fabric electrode, electrodes of different diameter, fabric weave, and weft density were devised, and the AC impedance, open-circuit voltage, and static ECG signal were measured and comprehensively evaluated. Diameter of 4 cm, 12/5 sateen, and weft density of 46 picks/cm were concluded as the appropriate parameters of the fabric electrode. ECG signals in swinging, squatting, and rotating states were compared between the woven fabric electrode and the standard medical electrode. The results showed that the characteristic waveform of the woven fabric electrode with 86.7% improved data was more obvious than that of the standard medical electrode. This work provides reference data that will be helpful for commercializing the integration of fabric electrodes into smart textiles.
Collapse
Affiliation(s)
- Meiling Zhang
- School of Textile Science and Engineering, Tiangong University, Tianjin 300387, China; (M.Z.); (N.G.); (Q.G.)
| | - Ningting Guo
- School of Textile Science and Engineering, Tiangong University, Tianjin 300387, China; (M.Z.); (N.G.); (Q.G.)
| | - Qian Gao
- School of Textile Science and Engineering, Tiangong University, Tianjin 300387, China; (M.Z.); (N.G.); (Q.G.)
| | - Hongqiang Li
- School of Electronic and Information Engineering, Tiangong University, Tianjin 300387, China;
| | - Zhangang Wang
- School of Software, Tiangong University, Tianjin 300387, China
- Correspondence:
| |
Collapse
|
6
|
Kim H, Kim S, Lim D, Jeong W. Development and Characterization of Embroidery-Based Textile Electrodes for Surface EMG Detection. SENSORS (BASEL, SWITZERLAND) 2022; 22:4746. [PMID: 35808240 PMCID: PMC9268917 DOI: 10.3390/s22134746] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 05/09/2022] [Revised: 06/15/2022] [Accepted: 06/21/2022] [Indexed: 06/15/2023]
Abstract
The interest in wearable devices has expanded to measurement devices for building IoT-based mobile healthcare systems and sensing bio-signal data through clothing. Surface electromyography, called sEMG, is one of the most popular bio-signals that can be applied to health monitoring systems. In general, gel-based (Ag/AgCl) electrodes are mainly used, but there are problems, such as skin irritation due to long-time wearing, deterioration of adhesion to the skin due to moisture or sweat, and low applicability to clothes. Hence, research on dry electrodes as a replacement is increasing. Accordingly, in this study, a textile-based electrode was produced with a range of electrode shapes, and areas were embroidered with conductive yarn using an embroidery technique in the clothing manufacturing process. The electrode was applied to EMG smart clothing for fitness, and the EMG signal detection performance was analyzed. The electrode shape was manufactured using the circle and wave type. The wave-type electrode was more morphologically stable than the circle-type electrode by up to 30% strain, and the electrode shape was maintained as the embroidered area increased. Skin-electrode impedance analysis confirmed that the embroidered area with conductive yarn affected the skin contact area, and the impedance decreased with increasing area. For sEMG performance analysis, the rectus femoris was selected as a target muscle, and the sEMG parameters were analyzed. The wave-type sample showed higher EMG signal strength than the circle-type. In particular, the electrode with three lines showed better performance than the fill-type electrode. These performances operated without noise, even with a commercial device. Therefore, it is expected to be applicable to the manufacture of electromyography smart clothing based on embroidered electrodes in the future.
Collapse
Affiliation(s)
- Hyelim Kim
- Material and Component Convergence R&D Department, Korea Institute of Industrial Technology (KITECH), Ansan 15588, Korea; (H.K.); (D.L.)
| | - Siyeon Kim
- Reliability Assesment Center, FITI Testing and Research Institute, Seoul 07791, Korea;
| | - Daeyoung Lim
- Material and Component Convergence R&D Department, Korea Institute of Industrial Technology (KITECH), Ansan 15588, Korea; (H.K.); (D.L.)
| | - Wonyoung Jeong
- Material and Component Convergence R&D Department, Korea Institute of Industrial Technology (KITECH), Ansan 15588, Korea; (H.K.); (D.L.)
| |
Collapse
|
7
|
Ohiri KA, Pyles CO, Hamilton LH, Baker MM, McGuire MT, Nguyen EQ, Osborn LE, Rossick KM, McDowell EG, Strohsnitter LM, Currano LJ. E-textile based modular sEMG suit for large area level of effort analysis. Sci Rep 2022; 12:9650. [PMID: 35688946 PMCID: PMC9187645 DOI: 10.1038/s41598-022-13701-4] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/12/2021] [Accepted: 05/05/2022] [Indexed: 11/16/2022] Open
Abstract
We present a novel design for an e-textile based surface electromyography (sEMG) suit that incorporates stretchable conductive textiles as electrodes and interconnects within an athletic compression garment. The fabrication and assembly approach is a facile combination of laser cutting and heat-press lamination that provides for rapid prototyping of designs in a typical research environment without need for any specialized textile or garment manufacturing equipment. The materials used are robust to wear, resilient to the high strains encountered in clothing, and can be machine laundered. The suit produces sEMG signal quality comparable to conventional adhesive electrodes, but with improved comfort, longevity, and reusability. The embedded electronics provide signal conditioning, amplification, digitization, and processing power to convert the raw EMG signals to a level-of-effort estimation for flexion and extension of the elbow and knee joints. The approach we detail herein is also expected to be extensible to a variety of other electrophysiological sensors.
Collapse
Affiliation(s)
- Korine A Ohiri
- Research and Exploratory Development Department, The Johns Hopkins Applied Physics Laboratory, Laurel, MD, 20723, USA
| | - Connor O Pyles
- Research and Exploratory Development Department, The Johns Hopkins Applied Physics Laboratory, Laurel, MD, 20723, USA
| | - Leslie H Hamilton
- Research and Exploratory Development Department, The Johns Hopkins Applied Physics Laboratory, Laurel, MD, 20723, USA
| | - Megan M Baker
- Research and Exploratory Development Department, The Johns Hopkins Applied Physics Laboratory, Laurel, MD, 20723, USA
| | - Matthew T McGuire
- Research and Exploratory Development Department, The Johns Hopkins Applied Physics Laboratory, Laurel, MD, 20723, USA
| | - Eric Q Nguyen
- Research and Exploratory Development Department, The Johns Hopkins Applied Physics Laboratory, Laurel, MD, 20723, USA
| | - Luke E Osborn
- Research and Exploratory Development Department, The Johns Hopkins Applied Physics Laboratory, Laurel, MD, 20723, USA
| | - Katelyn M Rossick
- Research and Exploratory Development Department, The Johns Hopkins Applied Physics Laboratory, Laurel, MD, 20723, USA
| | - Emil G McDowell
- Research and Exploratory Development Department, The Johns Hopkins Applied Physics Laboratory, Laurel, MD, 20723, USA
| | - Leah M Strohsnitter
- Air and Missile Defense Sector, The Johns Hopkins Applied Physics Laboratory, Laurel, MD, 20723, USA
| | - Luke J Currano
- Research and Exploratory Development Department, The Johns Hopkins Applied Physics Laboratory, Laurel, MD, 20723, USA.
| |
Collapse
|
8
|
Spanu A, Taki M, Baldazzi G, Mascia A, Cosseddu P, Pani D, Bonfiglio A. Epidermal Electrodes with Ferrimagnetic/Conductive Properties for Biopotential Recordings. Bioengineering (Basel) 2022; 9:bioengineering9050205. [PMID: 35621483 PMCID: PMC9137760 DOI: 10.3390/bioengineering9050205] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/18/2022] [Revised: 05/06/2022] [Accepted: 05/08/2022] [Indexed: 12/04/2022] Open
Abstract
Interfacing ultrathin functional films for epidermal applications with external recording instruments or readout electronics still represents one of the biggest challenges in the field of tattoo electronics. With the aim of providing a convenient solution to this ever-present limitation, in this work we propose an innovative free-standing electrode made of a composite thin film based on the combination of the conductive polymer PEDOT:PSS and ferrimagnetic powder. The proposed epidermal electrode can be directly transferred onto the skin and is structured in two parts, namely a conformal conductive part with a thickness of 3 μm and a ferrimagnetic-conductive part that can be conveniently connected using magnetic connections. The films were characterized for ECG recordings, revealing a performance comparable to that of commercial pre-gelled electrodes in terms of cross-spectral coherence, signal-to-noise ratio, and baseline wandering. These new, conductive, magnetically interfaceable, and free-standing conformal films introduce a novel concept in the domain of tattoo electronics and can set the basis for the development of a future family of epidermal devices and electrodes.
Collapse
Affiliation(s)
- Andrea Spanu
- Department of Electrical and Electronics Engineering, University of Cagliari, Piazza D’Armi, 09123 Cagliari, Italy; (M.T.); (G.B.); (A.M.); (P.C.); (D.P.); (A.B.)
- Correspondence:
| | - Mohamad Taki
- Department of Electrical and Electronics Engineering, University of Cagliari, Piazza D’Armi, 09123 Cagliari, Italy; (M.T.); (G.B.); (A.M.); (P.C.); (D.P.); (A.B.)
- Department of Electrical & Electronics Engineering, Lebanese International University, Beirut 146404, Lebanon
| | - Giulia Baldazzi
- Department of Electrical and Electronics Engineering, University of Cagliari, Piazza D’Armi, 09123 Cagliari, Italy; (M.T.); (G.B.); (A.M.); (P.C.); (D.P.); (A.B.)
- Department of Bioengineering, Robotics and System Engineering, University of Genoa, Via All’Opera Pia 13, 16145 Genova, Italy
| | - Antonello Mascia
- Department of Electrical and Electronics Engineering, University of Cagliari, Piazza D’Armi, 09123 Cagliari, Italy; (M.T.); (G.B.); (A.M.); (P.C.); (D.P.); (A.B.)
| | - Piero Cosseddu
- Department of Electrical and Electronics Engineering, University of Cagliari, Piazza D’Armi, 09123 Cagliari, Italy; (M.T.); (G.B.); (A.M.); (P.C.); (D.P.); (A.B.)
| | - Danilo Pani
- Department of Electrical and Electronics Engineering, University of Cagliari, Piazza D’Armi, 09123 Cagliari, Italy; (M.T.); (G.B.); (A.M.); (P.C.); (D.P.); (A.B.)
- Interdepartmental Center for Amyotrophic Lateral Sclerosis and Motor Neuron Diseases, 09100 Cagliari, Italy
| | - Annalisa Bonfiglio
- Department of Electrical and Electronics Engineering, University of Cagliari, Piazza D’Armi, 09123 Cagliari, Italy; (M.T.); (G.B.); (A.M.); (P.C.); (D.P.); (A.B.)
- Interdepartmental Center for Amyotrophic Lateral Sclerosis and Motor Neuron Diseases, 09100 Cagliari, Italy
- Department of Science, Technology and Society, Scuola Universitaria Superiore IUSS Pavia, Palazzo del Broletto, Piazza della Vittoria 15, 27100 Pavia, Italy
| |
Collapse
|
9
|
Abstract
Conductive polymers have attracted wide attention since their discovery due to their unique properties such as good electrical conductivity, thermal and chemical stability, and low cost. With different possibilities of preparation and deposition on surfaces, they present unique and tunable structures. Because of the ease of incorporating different elements to form composite materials, conductive polymers have been widely used in a plethora of applications. Their inherent mechanical tolerance limit makes them ideal for flexible devices, such as electrodes for batteries, artificial muscles, organic electronics, and sensors. As the demand for the next generation of (wearable) personal and flexible sensing devices is increasing, this review aims to discuss and summarize the recent manufacturing advances made on flexible electrochemical sensors.
Collapse
|
10
|
Jeong H, Feng J, Kim J. 2.5D Laser-Cutting-Based Customized Fabrication of Long-Term Wearable Textile sEMG Sensor: From Design to Intention Recognition. IEEE Robot Autom Lett 2022. [DOI: 10.1109/lra.2022.3190620] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/07/2022]
Affiliation(s)
- Hwayeong Jeong
- Department of Mechanical Engineering, Korea Advanced Institute of Science and Technology, Daejeon, Republic of Korea
| | - Jirou Feng
- Department of Mechanical Engineering, Korea Advanced Institute of Science and Technology, Daejeon, Republic of Korea
| | - Jung Kim
- Department of Mechanical Engineering, Korea Advanced Institute of Science and Technology, Daejeon, Republic of Korea
| |
Collapse
|
11
|
Vasconcelos B, Fiedler P, Machts R, Haueisen J, Fonseca C. The Arch Electrode: A Novel Dry Electrode Concept for Improved Wearing Comfort. Front Neurosci 2021; 15:748100. [PMID: 34733134 PMCID: PMC8558300 DOI: 10.3389/fnins.2021.748100] [Citation(s) in RCA: 6] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/27/2021] [Accepted: 09/27/2021] [Indexed: 11/27/2022] Open
Abstract
Electroencephalography (EEG) is increasingly used for repetitive and prolonged applications like neurofeedback, brain computer interfacing, and long-term intermittent monitoring. Dry-contact electrodes enable rapid self-application. A common drawback of existing dry electrodes is the limited wearing comfort during prolonged application. We propose a novel dry Arch electrode. Five semi-circular arches are arranged parallelly on a common baseplate. The electrode substrate material is a flexible thermoplastic polyurethane (TPU) produced by additive manufacturing. A chemical coating of Silver/Silver-Chloride (Ag/AgCl) is applied by electroless plating using a novel surface functionalization method. Arch electrodes were manufactured and validated in terms of mechanical durability, electrochemical stability, in vivo applicability, and signal characteristics. We compare the results of the dry arch electrodes with dry pin-shaped and conventional gel-based electrodes. 21-channel EEG recordings were acquired on 10 male and 5 female volunteers. The tests included resting state EEG, alpha activity, and a visual evoked potential. Wearing comfort was rated by the subjects directly after application, as well as at 30 min and 60 min of wearing. Our results show that the novel plating technique provides a well-adhering electrically conductive and electrochemically stable coating, withstanding repetitive strain and bending tests. The signal quality of the Arch electrodes is comparable to pin-shaped dry electrodes. The average channel reliability of the Arch electrode setup was 91.9 ± 9.5%. No considerable differences in signal characteristics have been observed for the gel-based, dry pin-shaped, and arch-shaped electrodes after the identification and exclusion of bad channels. The comfort was improved in comparison to pin-shaped electrodes and enabled applications of over 60 min duration. Arch electrodes required individual adaptation of the electrodes to the orientation and hairstyle of the volunteers. This initial preparation time of the 21-channel cap increased from an average of 5 min for pin-like electrodes to 15 min for Arch electrodes and 22 min for gel-based electrodes. However, when re-applying the arch electrode cap on the same volunteer, preparation times of pin-shaped and arch-shaped electrodes were comparable. In summary, our results indicate the applicability of the novel Arch electrode and coating for EEG acquisition. The novel electrode enables increased comfort for prolonged dry-contact measurement.
Collapse
Affiliation(s)
- Beatriz Vasconcelos
- Departamento de Engenharia Metalúrgica e de Materiais, Faculdade de Engenharia, Universidade do Porto, Porto, Portugal.,CEMUC - Department of Mechanical Engineering, University of Coimbra, Coimbra, Portugal
| | - Patrique Fiedler
- Institute of Biomedical Engineering and Informatics, Technische Universität Ilmenau, Ilmenau, Germany
| | - René Machts
- Institute of Biomedical Engineering and Informatics, Technische Universität Ilmenau, Ilmenau, Germany
| | - Jens Haueisen
- Institute of Biomedical Engineering and Informatics, Technische Universität Ilmenau, Ilmenau, Germany.,Department of Neurology, Biomagnetic Center, Jena University Hospital, Jena, Germany
| | - Carlos Fonseca
- Departamento de Engenharia Metalúrgica e de Materiais, Faculdade de Engenharia, Universidade do Porto, Porto, Portugal.,LAETA/INEGI, Institute of Science and Innovation in Mechanical and Industrial Engineering, Porto, Portugal
| |
Collapse
|
12
|
Blachowicz T, Ehrmann G, Ehrmann A. Textile-Based Sensors for Biosignal Detection and Monitoring. SENSORS (BASEL, SWITZERLAND) 2021; 21:6042. [PMID: 34577254 PMCID: PMC8470234 DOI: 10.3390/s21186042] [Citation(s) in RCA: 16] [Impact Index Per Article: 5.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 07/26/2021] [Revised: 08/16/2021] [Accepted: 09/07/2021] [Indexed: 02/06/2023]
Abstract
Biosignals often have to be detected in sports or for medical reasons. Typical biosignals are pulse and ECG (electrocardiogram), breathing, blood pressure, skin temperature, oxygen saturation, bioimpedance, etc. Typically, scientists attempt to measure these biosignals noninvasively, i.e., with electrodes or other sensors, detecting electric signals, measuring optical or chemical information. While short-time measurements or monitoring of patients in a hospital can be performed by systems based on common rigid electrodes, usually containing a large amount of wiring, long-term measurements on mobile patients or athletes necessitate other equipment. Here, textile-based sensors and textile-integrated data connections are preferred to avoid skin irritations and other unnecessary limitations of the monitored person. In this review, we give an overview of recent progress in textile-based electrodes for electrical measurements and new developments in textile-based chemical and other sensors for detection and monitoring of biosignals.
Collapse
Affiliation(s)
- Tomasz Blachowicz
- Center for Science and Education, Institute of Physics, Silesian University of Technology, 44-100 Gliwice, Poland;
| | - Guido Ehrmann
- Virtual Institute of Applied Research on Advanced Materials (VIARAM);
| | - Andrea Ehrmann
- Faculty of Engineering and Mathematics, Bielefeld University of Applied Sciences, 33619 Bielefeld, Germany
| |
Collapse
|
13
|
Spanu A, Botter A, Zedda A, Cerone GL, Bonfiglio A, Pani D. Dynamic Surface Electromyography Using Stretchable Screen-Printed Textile Electrodes. IEEE Trans Neural Syst Rehabil Eng 2021; 29:1661-1668. [PMID: 34398755 DOI: 10.1109/tnsre.2021.3104972] [Citation(s) in RCA: 7] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/08/2022]
Abstract
OBJECTIVE Wearable devices have created new opportunities in healthcare and sport sciences by unobtrusively monitoring physiological signals. Textile polymer-based electrodes proved to be effective in detecting electrophysiological potentials but suffer mechanical fragility and low stretch resistance. The goal of this research is to develop and validate in dynamic conditions cost-effective and easily manufacturable electrodes characterized by adequate robustness and signal quality. METHODS We here propose an optimized screen printing technique for the fabrication of PEDOT:PSS-based textile electrodes directly into finished stretchable garments for surface electromyography (sEMG) applications. A sensorised stretchable leg sleeve was developed, targeting five muscles of interest in rehabilitation and sport science. An experimental validation was performed to assess the accuracy of signal detection during dynamic exercises, including sit-to-stand, leg extension, calf raise, walking, and cycling. RESULTS The electrodes can resist up to 500 stretch cycles. Tests on five subjects revealed excellent contact impedance, and cross-correlation between sEMG envelopes simultaneously detected from the leg muscles by the textile and Ag/AgCl electrodes was generally greater than 0.9, which proves that it is possible to obtain good quality signals with performance comparable with disposable electrodes. CONCLUSIONS An effective technique to embed polymer-based electrodes in stretchable smart garments was presented, revealing good performance for dynamic sEMG detections. SIGNIFICANCE The achieved results pave the way to the integration of unobtrusive electrodes, obtained by screen printing of conductive polymers, into technical fabrics for rehabilitation and sport monitoring, and in general where the detection of sEMG in dynamic conditions is necessary.
Collapse
|
14
|
Hasan MM, Hossain MM. Nanomaterials-patterned flexible electrodes for wearable health monitoring: a review. JOURNAL OF MATERIALS SCIENCE 2021; 56:14900-14942. [PMID: 34219807 PMCID: PMC8237560 DOI: 10.1007/s10853-021-06248-8] [Citation(s) in RCA: 15] [Impact Index Per Article: 5.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 01/07/2021] [Accepted: 06/08/2021] [Indexed: 06/13/2023]
Abstract
ABSTRACT Electrodes fabricated on a flexible substrate are a revolutionary development in wearable health monitoring due to their lightweight, breathability, comfort, and flexibility to conform to the curvilinear body shape. Different metallic thin-film and plastic-based substrates lack comfort for long-term monitoring applications. However, the insulating nature of different polymer, fiber, and textile substrates requires the deposition of conductive materials to render interactive functionality to substrates. Besides, the high porosity and flexibility of fiber and textile substrates pose a great challenge for the homogenous deposition of active materials. Printing is an excellent process to produce a flexible conductive textile electrode for wearable health monitoring applications due to its low cost and scalability. This article critically reviews the current state of the art of different textile architectures as a substrate for the deposition of conductive nanomaterials. Furthermore, recent progress in various printing processes of nanomaterials, challenges of printing nanomaterials on textiles, and their health monitoring applications are described systematically.
Collapse
Affiliation(s)
- Md Mehdi Hasan
- Department of Textile Engineering, Khulna University of Engineering & Technology, Khulna, 9203 Bangladesh
- UNAM – National Nanotechnology Research Center and, Institute of Materials Science and Nanotechnology, Bilkent University, Ankara, 06800 Turkey
| | - Md Milon Hossain
- Department of Textile Engineering, Khulna University of Engineering & Technology, Khulna, 9203 Bangladesh
- Department of Textile Engineering, Chemistry and Science, North Carolina State University, Raleigh, 27606 USA
| |
Collapse
|
15
|
Cerone GL, Botter A, Vieira T, Gazzoni M. Design and Characterization of a Textile Electrode System for the Detection of High-Density sEMG. IEEE Trans Neural Syst Rehabil Eng 2021; 29:1110-1119. [PMID: 34097613 DOI: 10.1109/tnsre.2021.3086860] [Citation(s) in RCA: 6] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/09/2022]
Abstract
Muscle activity monitoring in dynamic conditions is a crucial need in different scenarios, ranging from sport to rehabilitation science and applied physiology. The acquisition of surface electromyographic (sEMG) signals by means of grids of electrodes (High-Density sEMG, HD-sEMG) allows obtaining relevant information on muscle function and recruitment strategies. During dynamic conditions, this possibility demands both a wearable and miniaturized acquisition system and a system of electrodes easy to wear, assuring a stable electrode-skin interface. While recent advancements have been made on the former issue, detection systems specifically designed for dynamic conditions are at best incipient. The aim of this work is to design, characterize, and test a wearable, HD-sEMG detection system based on textile technology. A 32-electrodes, 15 mm inter-electrode distance textile grid was designed and prototyped. The electrical properties of the material constituting the detection system and of the electrode-skin interface were characterized. The quality of sEMG signals was assessed in both static and dynamic contractions. The performance of the textile detection system was comparable to that of conventional systems in terms of stability of the traces, properties of the electrode-skin interface and quality of the collected sEMG signals during quasi-isometric and highly dynamic tasks.
Collapse
|
16
|
Gualandi I, Tessarolo M, Mariani F, Possanzini L, Scavetta E, Fraboni B. Textile Chemical Sensors Based on Conductive Polymers for the Analysis of Sweat. Polymers (Basel) 2021; 13:894. [PMID: 33799437 PMCID: PMC8000821 DOI: 10.3390/polym13060894] [Citation(s) in RCA: 19] [Impact Index Per Article: 6.3] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/27/2021] [Revised: 03/10/2021] [Accepted: 03/12/2021] [Indexed: 01/26/2023] Open
Abstract
Wearable textile chemical sensors are promising devices due to the potential applications in medicine, sports activities and occupational safety and health. Reaching the maturity required for commercialization is a technology challenge that mainly involves material science because these sensors should be adapted to flexible and light-weight substrates to preserve the comfort of the wearer. Conductive polymers (CPs) are a fascinating solution to meet this demand, as they exhibit the mechanical properties of polymers, with an electrical conductivity typical of semiconductors. Moreover, their biocompatibility makes them promising candidates for effectively interfacing the human body. In particular, sweat analysis is very attractive to wearable technologies as perspiration is a naturally occurring process and sweat can be sampled non-invasively and continuously over time. This review discusses the role of CPs in the development of textile electrochemical sensors specifically designed for real-time sweat monitoring and the main challenges related to this topic.
Collapse
Affiliation(s)
- Isacco Gualandi
- Dipartimento di Chimica Industriale ‘Toso Montanari’, Università di Bologna, Viale Risorgimento 4, 40136 Bologna, Italy;
| | - Marta Tessarolo
- Dipartimento di Fisica e Astronomia, Università di Bologna, Viale Berti Pichat 6/2, 40127 Bologna, Italy; (M.T.); (L.P.); (B.F.)
| | - Federica Mariani
- Dipartimento di Chimica Industriale ‘Toso Montanari’, Università di Bologna, Viale Risorgimento 4, 40136 Bologna, Italy;
| | - Luca Possanzini
- Dipartimento di Fisica e Astronomia, Università di Bologna, Viale Berti Pichat 6/2, 40127 Bologna, Italy; (M.T.); (L.P.); (B.F.)
| | - Erika Scavetta
- Dipartimento di Chimica Industriale ‘Toso Montanari’, Università di Bologna, Viale Risorgimento 4, 40136 Bologna, Italy;
| | - Beatrice Fraboni
- Dipartimento di Fisica e Astronomia, Università di Bologna, Viale Berti Pichat 6/2, 40127 Bologna, Italy; (M.T.); (L.P.); (B.F.)
| |
Collapse
|
17
|
Point of care TECHNOLOGIES. Digit Health 2021. [DOI: 10.1016/b978-0-12-818914-6.00008-9] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/19/2022] Open
|
18
|
Kubicek J, Fiedorova K, Vilimek D, Cerny M, Penhaker M, Janura M, Rosicky J. Recent Trends, Construction and Applications of Smart Textiles and Clothing for Monitoring of Health Activity: A Comprehensive Multidisciplinary Review. IEEE Rev Biomed Eng 2020; 15:36-60. [PMID: 33301410 DOI: 10.1109/rbme.2020.3043623] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/09/2022]
Abstract
In the area of biomedical signal monitoring, wearable electronics represents a dynamically growing field with a significant impact on the market of commercial products of biomedical signal monitoring and acquisition, as well as consumer electronic for vital functions monitoring. Since the electrodes are perceived as one of the most important part of the biomedical signal monitoring, they have been one of the most frequent subjects in the research community. Electronic textile (e-textile), also called smart textile represents a modern trend in the wearable electronics, integrating of functional materials with common clothing with the goal to realize the devices, which include sensors, antennas, energy harvesters and advanced textiles for self-cooling and heating. The area of textile electrodes and e-textile is perceived as a multidisciplinary field, integrating material engineering, chemistry, and biomedical engineering. In this review, we provide a comprehensive view on this area. This multidisciplinary review integrates the e-textile characteristics, materials and manufacturing of the textile electrodes, noise influence on the e-textiles performance, and mainly applications of the textile electrodes for biomedical signal monitoring and acquisition, including pressure sensors, electrocardiography, electromyography, electroencephalography and electrooculography monitoring.
Collapse
|
19
|
Kim S, Lee S, Jeong W. EMG Measurement with Textile-Based Electrodes in Different Electrode Sizes and Clothing Pressures for Smart Clothing Design Optimization. Polymers (Basel) 2020; 12:polym12102406. [PMID: 33086662 PMCID: PMC7603359 DOI: 10.3390/polym12102406] [Citation(s) in RCA: 14] [Impact Index Per Article: 3.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/15/2020] [Revised: 10/15/2020] [Accepted: 10/17/2020] [Indexed: 02/07/2023] Open
Abstract
The surface electromyography (SEMG) is one of the most popular bio-signals that can be applied in health monitoring systems, fitness training, and rehabilitation devices. Commercial clothing embedded with textile electrodes has already been released onto the market, but there is insufficient information on the performance of textile SEMG electrodes because the required configuration may differ according to the electrode material. The current study analyzed the influence of electrode size and pattern reduction rate (PRR), and hence the clothing pressure (Pc) based on in vivo SEMG signal acquisition. Bipolar SEMG electrodes were made in different electrode diameters Ø 5–30 mm, and the clothing pressure ranged from 6.1 to 12.6 mmHg. The results supported the larger electrodes, and Pc showed better SEMG signal quality by showing lower baseline noise and a gradual increase in the signal to noise ratio (SNR). In particular, electrodes, Ø ≥ 20 mm, and Pc ≥ 10 mmHg showed comparable performance to Ag-Ag/Cl electrodes in current textile-based electrodes. The current study emphasizes and discusses design factors that are particularly required in the designing and manufacturing process of smart clothing with SEMG electrodes, especially as an aspect of clothing design.
Collapse
|
20
|
Spanu A, Bonfiglio A, Pani D. Stretchable screen-printed PEDOT:PSS electrodes for upper-arm surface electromyography. ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY. IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY. ANNUAL INTERNATIONAL CONFERENCE 2020; 2020:4143-4146. [PMID: 33018910 DOI: 10.1109/embc44109.2020.9175701] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/06/2022]
Abstract
In the past ten years, wearable electronics underwent tremendous growth. Undoubtedly, one of the fields that led this trend is represented by biomedical applications. In this field, wearable technologies can provide unique features such as the unobtrusive monitoring of biopotentials. Polymerbased electrodes developed for this purpose can take advantage of their seamless integration in the garments. However, the available solutions exhibit fragility in relation with the stretchability of the fabric, causing significant performance degradation.In this work, this problem is tackled by a novel deposition approach based on screen-printing technology. The electrodes are deposited onto the pre-stretched fabric to ensure the full functionality during common operating conditions. To this aim, a novel PEDOT:PSS conductive ink formulation and printing procedure were conceived. In order to prove the electrode performance for surface electromyography, we printed the electrodes directly onto a commercial stretchable polyester sleeve for sport applications. The electrodes allowed to reliably record the muscular activity of the forearm with performance comparable to that of commercial gelled Ag/AgCl electrodes. The obtained results suggest that the proposed approach can be valuably used in health and fitness applications.
Collapse
|
21
|
Saadatnia Z, GhaffariMosanenzadeh S, Marquez Chin M, Naguib HE, Popovic MR. Flexible, Air Dryable, and Fiber Modified Aerogel-Based Wet Electrode for Electrophysiological Monitoring. IEEE Trans Biomed Eng 2020; 68:1820-1827. [PMID: 32897858 DOI: 10.1109/tbme.2020.3022615] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/10/2022]
Abstract
This study presents a novel type of wet electrode material for electrophysiological monitoring based on a conductive aerogel film. The electrode material incorporates cellulose nanocrystal and fiber as a biocompatible polymer and multi-walled carbon nanotube as a conductive filler. The fabricated electrode is fully characterized to explore the chemical, mechanical, electrical, and water absorption properties. The wet aerogel film presents suitable mechanical flexibility owing to the use of fiber enabling it to be conformal to curved surfaces like human body. The water absorption percentage of the fabricated aerogel film is extremely high (∼500%) due to the porosity of the film and hydrophilicity of the base polymer allowing it for effective wet electrode applications. The film is air dryable with a fast (∼10 min) and facile wetting process granting the electrode application for long-term, multiple use, and remote monitoring of patients. The electrical impedance range of the fabricated aerogel electrodes is relatively low (20 Ω/cm2-370 Ω/cm2) which is within the range of use for various electrophysiological monitoring purposes such as electrocardiography (ECG) and electroencephalography (EEG). Overall, the presented study introduces a novel wet electrode based on porous and electrically conductive aerogel film to be used for various biomedical applications.
Collapse
|
22
|
do Nascimento LMS, Bonfati LV, Freitas MLB, Mendes Junior JJA, Siqueira HV, Stevan SL. Sensors and Systems for Physical Rehabilitation and Health Monitoring-A Review. SENSORS (BASEL, SWITZERLAND) 2020; 20:E4063. [PMID: 32707749 PMCID: PMC7436073 DOI: 10.3390/s20154063] [Citation(s) in RCA: 32] [Impact Index Per Article: 8.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 06/12/2020] [Revised: 07/09/2020] [Accepted: 07/12/2020] [Indexed: 01/03/2023]
Abstract
The use of wearable equipment and sensing devices to monitor physical activities, whether for well-being, sports monitoring, or medical rehabilitation, has expanded rapidly due to the evolution of sensing techniques, cheaper integrated circuits, and the development of connectivity technologies. In this scenario, this paper presents a state-of-the-art review of sensors and systems for rehabilitation and health monitoring. Although we know the increasing importance of data processing techniques, our focus was on analyzing the implementation of sensors and biomedical applications. Although many themes overlap, we organized this review based on three groups: Sensors in Healthcare, Home Medical Assistance, and Continuous Health Monitoring; Systems and Sensors in Physical Rehabilitation; and Assistive Systems.
Collapse
Affiliation(s)
- Lucas Medeiros Souza do Nascimento
- Graduate Program in Electrical Engineering (PPGEE), Federal University of Technology of Parana (UTFPR), Ponta Grossa (PR) 84016-210, Brazil; (L.M.S.d.N.); (L.V.B.); (M.L.B.F.); (H.V.S.)
| | - Lucas Vacilotto Bonfati
- Graduate Program in Electrical Engineering (PPGEE), Federal University of Technology of Parana (UTFPR), Ponta Grossa (PR) 84016-210, Brazil; (L.M.S.d.N.); (L.V.B.); (M.L.B.F.); (H.V.S.)
| | - Melissa La Banca Freitas
- Graduate Program in Electrical Engineering (PPGEE), Federal University of Technology of Parana (UTFPR), Ponta Grossa (PR) 84016-210, Brazil; (L.M.S.d.N.); (L.V.B.); (M.L.B.F.); (H.V.S.)
| | - José Jair Alves Mendes Junior
- Graduate Program in Electrical Engineering and Industrial Informatics (CPGEI), Federal University of Technology of Parana (UTFPR), Curitiba (PR) 80230-901, Brazil;
| | - Hugo Valadares Siqueira
- Graduate Program in Electrical Engineering (PPGEE), Federal University of Technology of Parana (UTFPR), Ponta Grossa (PR) 84016-210, Brazil; (L.M.S.d.N.); (L.V.B.); (M.L.B.F.); (H.V.S.)
| | - Sergio Luiz Stevan
- Graduate Program in Electrical Engineering (PPGEE), Federal University of Technology of Parana (UTFPR), Ponta Grossa (PR) 84016-210, Brazil; (L.M.S.d.N.); (L.V.B.); (M.L.B.F.); (H.V.S.)
| |
Collapse
|
23
|
Ismar E, Kurşun Bahadir S, Kalaoglu F, Koncar V. Futuristic Clothes: Electronic Textiles and Wearable Technologies. GLOBAL CHALLENGES (HOBOKEN, NJ) 2020; 4:1900092. [PMID: 32642074 PMCID: PMC7330505 DOI: 10.1002/gch2.201900092] [Citation(s) in RCA: 22] [Impact Index Per Article: 5.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 11/07/2019] [Revised: 02/23/2020] [Accepted: 02/24/2020] [Indexed: 05/22/2023]
Abstract
This review summarizes the recent developments and importance of wearable electronic textiles in the past decade. Wearable electronic textiles are an emerging interdisciplinary research area that requires new design approaches. This challenging interdisciplinary research field brings together specialists in electronics, information technology, microsystems, and textiles to make an innovation in the development of wearable electronic products. Wearable electronic textiles play a key role among various technologies (clothing, communication, information, healthcare monitoring, military, sensors, magnetic shielding, etc.). In this review, applications of wearable electronic textiles are described, including an investigation of their fabrication techniques. This review highlights the basic processes, possible applications, and main materials to build wearable E-textiles and combines the fundamentals of E-textiles for the readers who have different backgrounds. Moreover, reliability, reusability, and efficiency of wearable electronic textiles are discussed together with the opportunities and drawbacks of the wearable E-textiles that are addressed in this review article.
Collapse
Affiliation(s)
- Ezgi Ismar
- Nano Science & Nano EngineeringIstanbul Technical UniversityIstanbul34467Turkey
| | - Senem Kurşun Bahadir
- Department of Mechanical EngineeringIstanbul Technical UniversityIstanbul34437Turkey
| | - Fatma Kalaoglu
- Department of Textile EngineeringIstanbul Technical UniversityIstanbul34437Turkey
| | - Vladan Koncar
- GEMTEXUniversity of LilleCité ScientifiqueVilleneuve d'AscqF‐59650France
- École Nationale Supérieure des Arts et Industries Textiles/Génie et Matériaux Textiles laboratory (ENSAIT/GEMTEX)2 Allée Louis et Victor ChampierRoubaixF‐59100France
| |
Collapse
|
24
|
Fu Y, Zhao J, Dong Y, Wang X. Dry Electrodes for Human Bioelectrical Signal Monitoring. SENSORS (BASEL, SWITZERLAND) 2020; 20:E3651. [PMID: 32610658 PMCID: PMC7374322 DOI: 10.3390/s20133651] [Citation(s) in RCA: 51] [Impact Index Per Article: 12.8] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 05/27/2020] [Revised: 06/20/2020] [Accepted: 06/25/2020] [Indexed: 11/16/2022]
Abstract
Bioelectrical or electrophysiological signals generated by living cells or tissues during daily physiological activities are closely related to the state of the body and organ functions, and therefore are widely used in clinical diagnosis, health monitoring, intelligent control and human-computer interaction. Ag/AgCl electrodes with wet conductive gels are widely used to pick up these bioelectrical signals using electrodes and record them in the form of electroencephalograms, electrocardiograms, electromyography, electrooculograms, etc. However, the inconvenience, instability and infection problems resulting from the use of gel with Ag/AgCl wet electrodes can't meet the needs of long-term signal acquisition, especially in wearable applications. Hence, focus has shifted toward the study of dry electrodes that can work without gels or adhesives. In this paper, a retrospective overview of the development of dry electrodes used for monitoring bioelectrical signals is provided, including the sensing principles, material selection, device preparation, and measurement performance. In addition, the challenges regarding the limitations of materials, fabrication technologies and wearable performance of dry electrodes are discussed. Finally, the development obstacles and application advantages of different dry electrodes are analyzed to make a comparison and reveal research directions for future studies.
Collapse
Affiliation(s)
- Yulin Fu
- Tsinghua Shenzhen International Graduate School, Tsinghua University, University Town of Shenzhen, Shenzhen 518055, China; (Y.F.); (X.W.)
| | - Jingjing Zhao
- Tsinghua-Berkeley Shenzhen Institute, Tsinghua University, University Town of Shenzhen, Shenzhen 518055, China;
| | - Ying Dong
- Tsinghua Shenzhen International Graduate School, Tsinghua University, University Town of Shenzhen, Shenzhen 518055, China; (Y.F.); (X.W.)
| | - Xiaohao Wang
- Tsinghua Shenzhen International Graduate School, Tsinghua University, University Town of Shenzhen, Shenzhen 518055, China; (Y.F.); (X.W.)
- Tsinghua-Berkeley Shenzhen Institute, Tsinghua University, University Town of Shenzhen, Shenzhen 518055, China;
| |
Collapse
|
25
|
Merletti R, Cerone GL. Tutorial. Surface EMG detection, conditioning and pre-processing: Best practices. J Electromyogr Kinesiol 2020; 54:102440. [PMID: 32763743 DOI: 10.1016/j.jelekin.2020.102440] [Citation(s) in RCA: 53] [Impact Index Per Article: 13.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/12/2020] [Revised: 06/13/2020] [Accepted: 06/20/2020] [Indexed: 10/24/2022] Open
Abstract
This tutorial is aimed primarily to non-engineers, using or planning to use surface electromyography (sEMG) as an assessment tool for muscle evaluation in the prevention, monitoring, assessment and rehabilitation fields. The main purpose is to explain basic concepts related to: (a) signal detection (electrodes, electrode-skin interface, noise, ECG and power line interference), (b) basic signal properties, such as amplitude and bandwidth, (c) parameters of the front-end amplifier (input impedance, noise, CMRR, bandwidth, etc.), (d) techniques for interference and artifact reduction, (e) signal filtering, (f) sampling and (g) A/D conversion, These concepts are addressed and discussed, with examples. The second purpose is to outline best practices and provide general guidelines for proper signal detection, conditioning and A/D conversion, aimed to clinical operators and biomedical engineers. Issues related to the sEMG origin and to electrode size, interelectrode distance and location, have been discussed in a previous tutorial. Issues related to signal processing for information extraction will be discussed in a subsequent tutorial.
Collapse
Affiliation(s)
- R Merletti
- LISiN - Laboratory for Engineering of the Neuromuscular System, Department of Electronics and Telecommunications - Politecnico di Torino, Turin, Italy.
| | - G L Cerone
- LISiN - Laboratory for Engineering of the Neuromuscular System, Department of Electronics and Telecommunications - Politecnico di Torino, Turin, Italy
| |
Collapse
|