1
|
Ko MJ, Park JH, Lee NR, Yoon JH, Kim YT, Cho SY. Success rates comparison of endodontic microsurgery and single implants with comprehensive and explicit criteria: a systematic review and meta-analysis. Restor Dent Endod 2025; 50:e8. [PMID: 39979225 PMCID: PMC11921458 DOI: 10.5395/rde.2025.50.e8] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/04/2024] [Accepted: 01/21/2025] [Indexed: 02/22/2025] Open
Abstract
Objectives While the success criteria of endodontic microsurgery (EMS) have been consistently defined and widely accepted, the success criteria of dental implants are outdated and focus only on the implant fixture and surrounding bone. This study aimed to evaluate the outcomes of EMS and single implants (SIs) with explicit criteria. Methods We searched for articles published from January 2010 to February 2022 and discussed them and consulted with a clinical advisory committee composed of four dental specialists and one epidemiologist during article selection and data extraction. Results Twenty-two EMS studies and six SI studies were included in the meta-analysis. Teeth treated using EMS had a pooled success rate of 89% (90% at <5-year follow-up and 80% at ≥5-year follow-up) and the pooled success rate of SI was 78%. Conclusions The success rates of the two procedures with similar follow-up periods were comparable. Subgroup analysis found no other variable that significantly influenced study heterogeneity. Considering the treatment sequence and the similar success rates, it would be advantageous to consider EMS, rather than implants, first in a situation where both procedures are applicable.
Collapse
Affiliation(s)
- Min Jung Ko
- Division for Healthcare Technology Assessment Research, National Evidence-Based Healthcare Collaborating Agency, Seoul, Korea
| | - Ju Hyun Park
- Department of Health Care Policy Research, Korea Institute for Health and Social Affairs, Sejong, Korea
| | - Na Rae Lee
- Division for Healthcare Technology Assessment Research, National Evidence-Based Healthcare Collaborating Agency, Seoul, Korea
| | - Joon-Ho Yoon
- Department of Prosthodontics, National Health Insurance Service Ilsan Hospital, Goyang, Korea
| | - Young-Taek Kim
- Department of Periodontology, National Health Insurance Service Ilsan Hospital, Goyang, Korea
| | - Sin-Yeon Cho
- Department of Conservative Dentistry, National Health Insurance Service Ilsan Hospital, Goyang, Korea
| |
Collapse
|
2
|
Yang F, Du Y, Zhang Z, Wang M, Yin W, Zhou Z, Li S, Hu Y, Chen J, Li J, Xu L, Wu W. Evaluation of microgaps and microleakage at the implant-abutment interface of individualized abutments in the maxillary anterior region under functional loading: A pragmatic clinical trial. J Prosthodont Res 2025; 69:58-67. [PMID: 39756872 DOI: 10.2186/jpr.jpr_d_23_00317] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/07/2025]
Abstract
PURPOSE This study aimed to evaluate the effect of functional loading on microgaps and microleakage at implant-abutment interfaces (IAIs) in the aesthetic zone when using different abutments and to provide a clinical reference for abutment selection. METHODS This study included 30 patients with 36 implants divided into three groups: zirconia (Zr)-one-piece custom abutment, titanium (Ti)-custom abutment, and Ti-original abutment. Scanning electron microscopy was used to examine alterations in the microgaps at the IAIs under functional loading. Changes in the bacterial endotoxin levels within the inner cavities of the implant were evaluated using a quantitative chromogenic Tachypleus amebocyte lysate test. These findings were subjected to statistical analysis using SPSS 18.0. RESULTS Before functional loading, there were no significant differences in the microgaps between groups (P > 0.05). In the Zr one-piece custom abutment group, the lingual microgaps significantly increased after 24 months of functional loading (P < 0.05). The bacterial endotoxin content significantly increased after 24 months of functional loading compared to the pre-loading levels (P < 0.05); however, no statistically significant difference was observed among the groups (P > 0.05). CONCLUSIONS Considering the limitations of this study, individualized one-piece Zr abutments exhibited a significant increase in lingual microgaps and comparable changes in microleakage to Ti abutments after 24 months of functional loading. Patients should be alert to the potential risks associated with the use of these abutments when they have heightened aesthetic expectations during functional loading.
Collapse
Affiliation(s)
- Feng Yang
- School and Hospital of Stomatology, Fujian Medical University, Fuzhou, China
- Department of Stomatology, The Affiliated Hospital of Xuzhou Medical University, Xuzhou, China
- School of Stomatology, Xuzhou Medical University, Xuzhou, China
| | - Yanxiao Du
- Department of Orthodontics, Qingdao Municipal Hospital, Qingdao, China
| | - Zheng Zhang
- School of Stomatology, Xuzhou Medical University, Xuzhou, China
| | - Mengya Wang
- School of Stomatology, Xuzhou Medical University, Xuzhou, China
| | - Wenjie Yin
- School of Stomatology, Xuzhou Medical University, Xuzhou, China
| | - Zheren Zhou
- Department of Stomatology, Yixing People's Hospital, Yixing, China
| | - Shengli Li
- Clinical Research Institute, The Affiliated Hospital of Xuzhou Medical University, Xuzhou, China
| | - Yiming Hu
- School of Stomatology, Xuzhou Medical University, Xuzhou, China
| | - Jiang Chen
- School and Hospital of Stomatology, Fujian Medical University, Fuzhou, China
| | - Jiafeng Li
- Department of Stomatology, The Affiliated Hospital of Xuzhou Medical University, Xuzhou, China
| | - Liang Xu
- Department of Stomatology, The First Affiliated Hospital of Fujian Medical University, Fuzhou, China
| | - Weiliang Wu
- School and Hospital of Stomatology, Fujian Medical University, Fuzhou, China
| |
Collapse
|
3
|
Deste Gökay G, Gökçimen G, Oyar P, Durkan R. Comparison of fatigue lifetime of new generation CAD/CAM crown materials on zirconia and titanium abutments in implant-supported crowns: a 3D finite element analysis. BIOMED ENG-BIOMED TE 2024; 69:575-584. [PMID: 38997228 DOI: 10.1515/bmt-2024-0017] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/17/2024] [Accepted: 07/04/2024] [Indexed: 07/14/2024]
Abstract
OBJECTIVES Due to the dynamic character of the stomatognathic system, fatigue life experiments simulating the cyclic loading experienced by implant-supported restorations are critical consideration. The aim of this study was to examine the effect of different crown and abutment materials on fatigue failure of single implant-supported crowns. METHODS Models were created for 10 different designs of implant-supported single crowns including two zirconia-reinforced lithium silicates (crystallized and precrystallized), monolithic lithium disilicate, polymer-infiltrated ceramic networks, and polyetheretherketone supported by zirconia and titanium abutments. A cyclic load of 179 N with a frequency of 1 Hz was applied on palatal cusp of a maxillary first premolar at a 30° angle in a buccolingual direction. RESULTS In the models with titanium abutments, the polymer-infiltrated ceramic network model had a lower number of cycles to fatigue failure values in the implant (5.07), abutment (2.30), and screw (1.07) compared to others. In the models with zirconia abutments, the crystallized zirconia-reinforced lithium silicate model had a higher number of cycles to fatigue failure values in the abutment (8.52) compared to others. Depending on the fatigue criteria, polyetheretherketone implant crown could fail in less than five year while the other implant crowns exhibits an infinite life on all models. CONCLUSIONS The type of abutment material had an effect on the number of cycles to fatigue failure values for implants, abutments, and screws, but had no effect on crown materials. The zirconia abutment proved longer fatigue lifetime, and should thus be considered for implant-supported single crowns.
Collapse
Affiliation(s)
- Gonca Deste Gökay
- Faculty of Dentistry, Department of Prosthodontics, 105810 Bursa Uludağ University , Bursa, Türkiye
| | - Gülsüm Gökçimen
- Department of Prosthodontics, Ankara 75th year Oral and Dental Health Hospital, Ankara, Türkiye
| | - Perihan Oyar
- School of Health Services, Dental Prosthetics Technology, Hacettepe University, Ankara, Türkiye
| | - Rukiye Durkan
- Faculty of Dentistry, Department of Prosthodontics, Istanbul Okan University, Istanbul, Türkiye
| |
Collapse
|
4
|
Alghanaim N, Kern M, Yazigi C, Chaar MS. Effects of sterilization, conditioning, and thermal aging on the retention of zirconia hybrid abutments: A laboratory study. Clin Implant Dent Relat Res 2024; 26:679-687. [PMID: 38680076 DOI: 10.1111/cid.13332] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/26/2023] [Revised: 04/05/2024] [Accepted: 04/08/2024] [Indexed: 05/01/2024]
Abstract
OBJECTIVE To investigate the effects of sterilization, conditioning method, and thermal aging on the retentive strength of two-piece zirconia abutments. MATERIALS AND METHODS In total, 128 stock zirconia abutments were divided into four groups (n = 32) according to the conditioning parameters: (A) air-abrasion using 50 μm alumina particles/1.0 bar, (B) 50 μm/2.0 bar, (C) 100 μm/1.0 bar, and (D) 100 μm/2.0 bar. All abutments were bonded onto titanium bases using DTK adhesive resin and stored in water bath (37°C) for 72 h. Each group was subdivided into two subgroups (n = 16), group 1 was disinfected, whereas group 2 followed disinfection and autoclave sterilization. Half of the specimens of each subgroup (n = 8) was directly subjected to the axial retention test (groups N), while the other half was first subjected to 150 days of thermocycling followed by retention test (groups T). Statistical analysis was performed with three-way ANOVA, additional statistical analysis was performed by using separate one-way ANOVAs followed by the Tukey's post-hoc test for post hoc pairwise comparisons among groups. RESULTS The highest median retention strength was recorded for group B2N (1390 N), whereas the lowest strength was recorded for group C1T (688 N). No significant interaction (p ≥ 0.05) was detected between the different variables; conditioning method, sterilization, and the thermal cycling regarding the effect on the resulting retention. However, the sterilization always showed a positive effect. Thermocycling presented an adversely significant effect only in the absence of sterilization (p < 0.05), with the exception of subgroups A. For the sterilized groups, thermocycling had no statistically significant effect on the retention. CONCLUSION Steam autoclaving increased the retention of hybrid zirconia abutments. DTK adhesive resin for two-piece zirconia abutments performed well after sterilization and thermocycling.
Collapse
Affiliation(s)
- Nalah Alghanaim
- Department of Prosthodontics, Propaedeutics and Dental Materials, School of Dentistry, Christian-Albrechts University, Kiel, Germany
- Department of Prosthodontics, Faculty of Dentistry, King Abdulaziz University, Jeddah, Saudi Arabia
| | - Matthias Kern
- Department of Prosthodontics, Propaedeutics and Dental Materials, School of Dentistry, Christian-Albrechts University, Kiel, Germany
| | - Christine Yazigi
- Department of Prosthodontics, Propaedeutics and Dental Materials, School of Dentistry, Christian-Albrechts University, Kiel, Germany
| | - M Sad Chaar
- Department of Prosthodontics, Propaedeutics and Dental Materials, School of Dentistry, Christian-Albrechts University, Kiel, Germany
| |
Collapse
|
5
|
Olander J, Barkarmo S, Hammarström Johansson P, Wennerberg A, Stenport VF. Inflammatory Gene Profile and Particle Presence in Peri-Implant Mucosa: a Pilot Study on 9 Patients. J Oral Maxillofac Res 2023; 14:e2. [PMID: 37969950 PMCID: PMC10645473 DOI: 10.5037/jomr.2023.14302] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/22/2023] [Accepted: 09/27/2023] [Indexed: 11/17/2023]
Abstract
Objectives The purpose of this pilot study is to compare gene expression in mucosa around dental implants with zirconia abutment to titanium and investigate presence of particles in mucosa samples and on implant heads. Material and Methods Ten patients with a single implant supported prosthesis connected to zirconia or titanium abutments were invited at the five-year control. A clinical examination and a survey on experience of function and appearance were conducted. A mucosa biopsy taken in close vicinity to the implant were analysed by real-time polymerase chain reaction (qPCR) and presence of particles in a scanning electron microscope/energy-dispersive X-ray spectroscope (SEM/EDX). Cytological smear samples were collected and analysed through inductively coupled plasma mass spectrometry (ICP-MS) to investigate presence of particles on implant heads. Results In total, 9 patients participated in the study, five with titanium abutments and four with zirconia abutments. All patients were satisfied with function and aesthetics. Titanium and iron particles were detected in mucosa biopsies. The ICP - MS analysis demonstrated presence of zirconia and titanium. Several proinflammatory genes were upregulated in the zirconia abutment group. Conclusions Around zirconia abutments a slight increase in proinflammatory response and amount of wear particles was seen as compared to titanium. Wear particles of titanium were present in all soft tissue samples, however zirconia particles only in the samples from implants heads/mucosa with zirconia abutments.
Collapse
Affiliation(s)
- Julia Olander
- Department of Prosthodontics and Dental Materials Science, Institute of Odontology, The Sahlgrenska Academy, University of Gothenburg, GothenburgSweden.
| | - Sargon Barkarmo
- Department of Prosthodontics and Dental Materials Science, Institute of Odontology, The Sahlgrenska Academy, University of Gothenburg, GothenburgSweden.
| | - Petra Hammarström Johansson
- Department of Prosthodontics and Dental Materials Science, Institute of Odontology, The Sahlgrenska Academy, University of Gothenburg, GothenburgSweden.
| | - Ann Wennerberg
- Department of Prosthodontics and Dental Materials Science, Institute of Odontology, The Sahlgrenska Academy, University of Gothenburg, GothenburgSweden.
| | - Victoria Franke Stenport
- Department of Prosthodontics and Dental Materials Science, Institute of Odontology, The Sahlgrenska Academy, University of Gothenburg, GothenburgSweden.
| |
Collapse
|
6
|
Tonin BSH, Fu J, He Y, Ye N, Chew HP, Fok A. The effect of abutment material stiffness on the mechanical behavior of dental implant assemblies: A 3D finite element study. J Mech Behav Biomed Mater 2023; 142:105847. [PMID: 37127010 DOI: 10.1016/j.jmbbm.2023.105847] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/09/2023] [Revised: 04/07/2023] [Accepted: 04/10/2023] [Indexed: 05/03/2023]
Abstract
PURPOSE This study aimed to evaluate the stress distribution and microgap formation in implant assemblies with conical abutments made of different materials under an oblique load. MATERIALS AND METHODS The mechanical behavior of an implant assembly with a titanium abutment was analyzed and compared with that of an assembly with a Y-TZP abutment using finite element analysis (FEA). A torque of 20 Ncm was first applied to the abutment screw, followed by oblique loads of 10 N-280 N applied to the prosthesis placed on the implant. The maximum stress in the abutment screw, the microgap formation process, and the critical load for bridging the internal implant space were evaluated. RESULTS No significant difference in stress distribution between the two cases was observed, with the stresses being mainly concentrated at the top half of the screw (the predicted maximum von Mises stress was approximately 1200 MPa at 280 N). The area in contact at the implant-to-abutment interface decreased with increasing load for both abutments, with the critical load for bridging the internal implant space being roughly 140 N. The maximum gap size being was approximately 470 μm with either abutment. CONCLUSION There was no significant difference in the stress distribution or microgap formed between implant assemblies with titanium and Y-TZP abutments having an internal conical connection.
Collapse
Affiliation(s)
- Bruna S H Tonin
- Department of Dental Materials and Prosthesis, School of Dentistry of Ribeirão Preto, University of São Paulo (USP), Ribeirão Preto, SP, Brazil
| | - Jing Fu
- Department of Prosthodontics, The Affiliated Hospital of Qingdao University, School of Stomatology of Qingdao University, China
| | - Yiting He
- Department of Prosthodontics, Hospital of Stomatology, Sun Yat-sen University, Guangdong Provincial Key Laboratory of Stomatology, Guangzhou, Guangdong, China
| | - Ning Ye
- Minnesota Dental Research Center for Biomaterials and Biomechanics, School of Dentistry, University of Minnesota, Minneapolis, MN, USA
| | - Hooi Pin Chew
- Minnesota Dental Research Center for Biomaterials and Biomechanics, School of Dentistry, University of Minnesota, Minneapolis, MN, USA
| | - Alex Fok
- Minnesota Dental Research Center for Biomaterials and Biomechanics, School of Dentistry, University of Minnesota, Minneapolis, MN, USA.
| |
Collapse
|
7
|
Saponaro PC, Karasan D, Donmez MB, Johnston WM, Yilmaz B. Prosthetic complications with monolithic or micro-veneered implant-supported zirconia single-unit, multiple-unit, and complete-arch prostheses on titanium base abutments: A single center retrospective study with mean follow-up period of 72.35 months. Clin Implant Dent Relat Res 2023; 25:99-106. [PMID: 36321480 DOI: 10.1111/cid.13149] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/29/2022] [Revised: 09/13/2022] [Accepted: 10/14/2022] [Indexed: 11/05/2022]
Abstract
BACKGROUND The influence of prosthetic design on prosthetic complications when monolithic or micro-veneered zirconia prostheses are supported with titanium base (ti-base) abutments is not well-known. PURPOSE The purpose of this single center, retrospective study was to assess the prevalence of prosthetic complications with monolithic or micro-veneered single-unit, multi-unit, and complete-arch zirconia prostheses supported with ti-base abutments (implant level or multi-unit abutment level). MATERIAL AND METHODS This study retrospectively evaluated the electronic health record (EHR) of participants who received either monolithic or micro-veneered implant-supported single-unit, multi-unit, and/or complete-arch prostheses supported by ti-base or zirconia-ti-base hybrid abutments delivered between the years 2010 and 2021. Data were analyzed by using logistic regression and Exact Mantel-Haenszel chi-square test (α = 0.05) to assess the clinical performance of prostheses and complications including crown decementation, feldspathic porcelain chipping, prosthesis fracture, zirconia-ti-base hybrid abutment decementation, abutment screw loosening, screw fracture, abutment fracture, implant loss, and prosthesis remake. RESULTS The study included 94 participants (50 female, 44 male) with a mean age of 59.5 years (range: 24-101 years of age). The retrospective EHR evaluation yielded 82 single-unit, 51 multi-unit, and 20 complete-arch prostheses on 325 implants. Among 153 prostheses delivered, 108 were micro-veneered (47 single-unit, 41 multi-unit, and 20 complete-arch prostheses) and 45 were monolithic. The average duration was 72.35 months (6.02 years) with a follow-up period of 5-132 months. From the time of insertion to the time of EHR review, of 153 prostheses, 78.43% did not exhibit any prosthetic complication. However, 33 prostheses (21.57%) from 29 participants (30.85%) had at least one prosthetic complication. Only four patients (4.25%) experienced two or more prosthetic complications. Prosthetic design affected the probability of having a complication (p = 0.005); complete-arch prostheses had higher probability (p ≤ 0.028). Single-unit prostheses had lower probability of complication than multi-unit prostheses (p = 0.005). The most commonly observed complication was fracture of veneering material (5.88%) followed by prosthetic screw loosening (4.57%) and decementation between the zirconia and the ti-base abutment (2.61%). Micro-veneered complete-arch prostheses had higher probability of having chipping than that of not having (p < 0.001), and other micro-veneered prosthetic designs had similar probability of chipping with that of complete-arch prostheses (p ≥ 0.082). Frequency of chipping was affected by veneering (p < 0.001). Monolithic prostheses had lower probability of chipping than micro-veneered prostheses, regardless of the prosthetic design (p < 0.001). CONCLUSIONS The frequency of prosthetic complications varied depending on prosthetic design. Complete-arch prostheses had the highest probability of complications while the single-unit prostheses had the lowest. Micro-veneered prostheses had higher probability for chipping than monolithic prostheses. Probability of chipping was similar for micro-veneered single-unit, multi-unit, and complete-arch zirconia prostheses.
Collapse
Affiliation(s)
- Paola C Saponaro
- Division of Restorative and Prosthetic Dentistry, The Ohio State University College of Dentistry, Columbus, Ohio, USA
| | - Duygu Karasan
- Division of Fixed Prosthodontics and Biomaterials, University Clinics for Dental Medicine, University of Geneva, Geneva, Switzerland
| | - Mustafa Borga Donmez
- Department of Prosthodontics, Faculty of Dentistry, Istinye University, Istanbul, Turkey.,Department of Reconstructive Dentistry and Gerodontology, School of Dental Medicine, University of Bern, Bern, Switzerland
| | - William Michael Johnston
- Division of Restorative and Prosthetic Dentistry, The Ohio State University College of Dentistry, Columbus, Ohio, USA
| | - Burak Yilmaz
- Division of Restorative and Prosthetic Dentistry, The Ohio State University College of Dentistry, Columbus, Ohio, USA.,Department of Reconstructive Dentistry and Gerodontology, School of Dental Medicine, University of Bern, Bern, Switzerland.,Department of Restorative, Preventive and Pediatric Dentistry, School of Dental Medicine, University of Bern, Bern, Switzerland
| |
Collapse
|
8
|
Kihara H, Hatakeyama W, Kondo H, Yamamori T, Baba K. Current complications and issues of implant superstructure. J Oral Sci 2022; 64:257-262. [PMID: 35989295 DOI: 10.2334/josnusd.21-0534] [Citation(s) in RCA: 9] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/01/2022]
Abstract
The purpose of this review is to search for complications of dental implant superstructures and consider the issues involved. This narrative review was performed by searching through PubMed databases and review articles that were published after 1990. Misfitting of the superstructure can result in loosening of screws, reduced preload, and in some cases, significant stress around the implant. External connection modalities and single implant prostheses have been reported to have more loose or broken abutment screws. In addition, when zirconia abutment was used for platform shifting, the rate of fracture of the abutment was considered to be high. Additionally, it was reported that men were significantly at an increased risk of abutment fracture. As for the retention mechanism of implant overdenture, stud attachment (Locator type) should receive more attention to wear and damage of retention parts than other attachments. The causes of the complications of implant superstructures have not been clarified in some cases, and further verification is required. Verification of complications is considered important to obtain a long-term prognosis for superstructures of implants. It will be necessary to further verify complications of implants in the future.
Collapse
Affiliation(s)
- Hidemichi Kihara
- Department of Prosthodontics and Oral Implantology, Iwate Medical University School of Dentistry
| | - Wataru Hatakeyama
- Department of Prosthodontics and Oral Implantology, Iwate Medical University School of Dentistry
| | - Hisatomo Kondo
- Department of Prosthodontics and Oral Implantology, Iwate Medical University School of Dentistry
| | - Tetsuo Yamamori
- Department of Prosthetic Dentistry, Ohu University School of Dentistry
| | - Kazuyoshi Baba
- Department of Prosthodontics, Showa University School of Dentistry
| |
Collapse
|
9
|
Papalexopoulos D, Samartzi TK, Tsirogiannis P, Sykaras N, Sarafianou A, Kourtis S, Mikeli A. Impact of maxillofacial growth on implants placed in adults: A narrative review. J ESTHET RESTOR DENT 2022; 35:467-478. [PMID: 35929493 DOI: 10.1111/jerd.12950] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/04/2022] [Revised: 07/15/2022] [Accepted: 07/19/2022] [Indexed: 11/26/2022]
Abstract
OBJECTIVE To determine the effect of lifetime maxillofacial changes on dental implants placed in adults, analyze the clinical implications of these changes, identify prognostic factors, and offer possible solutions. OVERVIEW The relationship between implant placement and maxillofacial changes, occurring during not only the active growth period but also the entire span of adulthood, has not been extensively examined. Vertical differences between implants and adjacent teeth due to the ankylotic behavior of the former might be observed at any age and endanger restoration biologically, functionally, and esthetically. Regarding interproximal contacts, firm contact loss may occur within a few months after restoration, resulting in food impaction. Many prognostic factors have been reported, but most do not exhibit a statistically significant association with implant infraocclusion and interproximal contact loss. Incorporation of alternative solutions, accurate treatment planning, strict recall protocols, and retrievability of implant-supported restorations can facilitate efficient management of complications. CONCLUSION Maxillomandibular changes throughout adulthood may lead to complications such as implant infraocclusion and interproximal contact loss. Rehabilitation of edentulism should be characterized by well-designed and flexible treatment plans to resolve long-term complications efficiently. Further long-term clinical studies are needed to identify other risk factors. CLINICAL SIGNIFICANCE Treatment plans for implant therapy should be reconsidered for adults. Careful patient monitoring and early intervention are essential for securing treatment outcomes.
Collapse
Affiliation(s)
- Dimokritos Papalexopoulos
- Department of Prosthodontics, School of Dentistry, National and Kapodistrian University of Athens, Zografou, Greece
| | | | - Panagiotis Tsirogiannis
- Department of Prosthodontics, School of Dentistry, National and Kapodistrian University of Athens, Zografou, Greece
| | - Nikitas Sykaras
- Department of Prosthodontics, School of Dentistry, National and Kapodistrian University of Athens, Zografou, Greece
| | - Aspasia Sarafianou
- Department of Prosthodontics, School of Dentistry, National and Kapodistrian University of Athens, Zografou, Greece
| | - Stefanos Kourtis
- Department of Prosthodontics, School of Dentistry, National and Kapodistrian University of Athens, Zografou, Greece
| | - Aikaterini Mikeli
- Department of Prosthodontics, School of Dentistry, National and Kapodistrian University of Athens, Zografou, Greece
| |
Collapse
|
10
|
Kraus RD, Espuelas C, Hämmerle CHF, Jung RE, Sailer I, Thoma DS. Five-year randomized controlled clinical study comparing cemented and screw-retained zirconia-based implant-supported single crowns. Clin Oral Implants Res 2022; 33:537-547. [PMID: 35224774 PMCID: PMC9313572 DOI: 10.1111/clr.13913] [Citation(s) in RCA: 10] [Impact Index Per Article: 3.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/06/2021] [Revised: 01/17/2022] [Accepted: 02/09/2022] [Indexed: 11/29/2022]
Abstract
Objectives To compare screw‐retained and cemented all‐ceramic implant‐supported single crowns regarding biological and technical outcomes over a 5‐year observation period. Materials and methods In 44 patients, 44 two‐piece dental implants were placed in single‐tooth gaps in the esthetic zone. Patients randomly received a screw‐retained (SR) or cemented (CR) all‐ceramic single crown and were then re‐examined annually up to 5 years. Outcome measures included: clinical, biological, technical, and radiographic parameters. Data were statistically analyzed with Wilcoxon–Mann–Whitney, Wilcoxon, and Fisher's exact tests. Results During the observation period, three patients (6.8%) were loss to follow‐up. Eight restorations (18.2%, CI (8.2%, 32.7%)) were lost due to technical (6 patients, 13.6% (CI (5.2%, 27.4%)), 2 CR and 4 SR group, intergroup p = .673; implants still present) or biological complications (2 patients, 4.5% (CI (0.6%, 16.5%)), only CR group, intergroup p = .201, both implants lost). This resulted in a survival rate of 81.2% (CI (65.9%, 90.1%)) on the restorative level (18 SR; 15 CR, 3 lost to follow‐up). At the 5‐year follow‐up, the median marginal bone levels were located slightly apical relative to the implant shoulder with 0.4 mm (0.5; 0.3) (SR) and 0.4 mm (0.8; 0.3) (CR) (intergroup p = .582). Cemented restorations demonstrated a significantly higher biological complication rate (36.8%, SR: 0.0%; intergroup p = .0022), as well as a significantly higher overall complication rate (68.4%, SR: 22.7%, intergroup p = .0049). All other outcomes did not differ significantly between the two groups (p > .05). Conclusions All‐ceramic single‐tooth restorations on two‐piece dental implants resulted in a relatively low survival rate. Cemented restorations were associated with a higher biological and overall complication rate than screw‐retained restorations.
Collapse
Affiliation(s)
- Riccardo D Kraus
- Clinic of Reconstructive Dentistry, Center of Dental Medicine, University of Zurich, Zurich, Switzerland
| | - Catharina Espuelas
- Clinic of Reconstructive Dentistry, Center of Dental Medicine, University of Zurich, Zurich, Switzerland
| | - Christoph H F Hämmerle
- Clinic of Reconstructive Dentistry, Center of Dental Medicine, University of Zurich, Zurich, Switzerland
| | - Ronald E Jung
- Clinic of Reconstructive Dentistry, Center of Dental Medicine, University of Zurich, Zurich, Switzerland
| | - Irena Sailer
- Division of Fixed Prosthodontics and Biomaterials, University Clinics for Dental Medicine, University of Geneva, Geneva, Switzerland
| | - Daniel S Thoma
- Clinic of Reconstructive Dentistry, Center of Dental Medicine, University of Zurich, Zurich, Switzerland
| |
Collapse
|
11
|
Lamperti ST, Wolleb K, Hämmerle CHF, Jung RE, Hüsler J, Thoma DS. Cemented versus screw-retained zirconia-based single implant restorations: 5-year results of a randomized controlled clinical trial. Clin Oral Implants Res 2022; 33:353-361. [PMID: 35051314 PMCID: PMC9305781 DOI: 10.1111/clr.13895] [Citation(s) in RCA: 7] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/21/2021] [Revised: 11/26/2021] [Accepted: 12/30/2021] [Indexed: 11/26/2022]
Abstract
Objectives To compare cemented and screw‐retained one‐piece zirconia‐based restorations in terms of clinical, radiographic, and technical outcomes 5 years after insertion. Materials and methods Thirty‐four patients with single‐tooth implants were randomly restored with either a cemented lithium disilicate crown on a one‐piece customized zirconia abutment (CEM, 17 patients) or a screw‐retained crown based on a directly veneered one‐piece customized zirconia abutment (SCREW, 16 patients). All patients were recalled for a baseline examination (7–10 days after crown insertion) and then annually up to 5 years. The following outcomes were assessed: marginal bone level (changes), technical, and clinical (bleeding on probing, plaque control record, probing depth, and keratinized tissue) parameters. The Mann–Whitney U‐test was used to assess differences between the two groups. Results At 5 years, 26 patients (13 in each group) were re‐examined. The survival rates on the implant and restorative levels were 100% and 82.4% (equally for both groups), respectively. At 5 years, the median marginal bone level was located at −0.15 mm (IQR: −0.89 mm; 0.27 mm) (CEM) and −0.26 mm (IQR: −0.38 mm; 0.01 mm) (SCREW) below the implant shoulder (intergroup p = .9598). The median changes between baseline and the 5‐year follow‐up amounted to −0.23 mm (CEM; intragroup p = .0002) and −0.15 mm (SCREW; intragroup p = .1465) (intergroup p = .1690). The overall technical complication rate at 5 years was 15.4% (CEM) and 15.4% (SCREW) (intergroup p = 1.00). Clinical parameters remained stable over time (baseline to 5 years). Conclusions At 5 years, screw‐retained and cemented restorations rendered largely the same clinical, technical, and radiographic outcomes. Technical complications were frequent in both groups.
Collapse
Affiliation(s)
- Sofia T Lamperti
- Clinic of Reconstructive Dentistry, University of Zurich, Zurich, Switzerland
| | | | | | - Ronald E Jung
- Clinic of Reconstructive Dentistry, University of Zurich, Zurich, Switzerland
| | - Jürg Hüsler
- Clinic of Reconstructive Dentistry, University of Zurich, Zurich, Switzerland
| | - Daniel S Thoma
- Clinic of Reconstructive Dentistry, University of Zurich, Zurich, Switzerland.,Department of Periodontology, Research Institute for Periodontal Regeneration, College of Dentistry, Yonsei University, Seoul, Korea
| |
Collapse
|
12
|
Wear particle release at the interface of dental implant components: Effects of different material combinations. An in vitro study. Dent Mater 2022; 38:508-516. [DOI: 10.1016/j.dental.2022.01.001] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/31/2021] [Accepted: 01/07/2022] [Indexed: 11/24/2022]
|
13
|
Pjetursson BE, Sailer I, Latyshev A, Rabel K, Kohal RJ, Karasan D. A systematic review and meta-analysis evaluating the survival, the failure, and the complication rates of veneered and monolithic all-ceramic implant-supported single crowns. Clin Oral Implants Res 2021; 32 Suppl 21:254-288. [PMID: 34642991 PMCID: PMC9293296 DOI: 10.1111/clr.13863] [Citation(s) in RCA: 72] [Impact Index Per Article: 18.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/30/2021] [Accepted: 08/04/2021] [Indexed: 12/28/2022]
Abstract
Objective To assess the survival, failure, and complication rates of veneered and monolithic all‐ceramic implant‐supported single crowns (SCs). Methods Literature search was conducted in Medline (PubMed), Embase, and Cochrane Central Register of Controlled Trials until September 2020 for randomized, prospective, and retrospective clinical trials with follow‐up time of at least 1 year, evaluating the outcome of veneered and/or monolithic all‐ceramic SCs supported by titanium dental implants. Survival and complication rates were analyzed using robust Poisson's regression models. Results Forty‐nine RCTs and prospective studies reporting on 57 material cohorts were included. Meta‐analysis of the included studies indicated an estimated 3‐year survival rate of veneered‐reinforced glass‐ceramic implant‐supported SCs of 97.6% (95% CI: 87.0%–99.6%). The estimated 3‐year survival rates were 97.0% (95% CI: 94.0%–98.5%) for monolithic‐reinforced glass‐ceramic implant SCs, 96.9% (95% CI: 93.4%–98.6%) for veneered densely sintered alumina SCs, 96.3% (95% CI: 93.9%–97.7%) for veneered zirconia SCs, 96.1% (95% CI: 93.4%–97.8%) for monolithic zirconia SCs and only 36.3% (95% CI: 0.04%–87.7%) for resin‐matrix‐ceramic (RMC) SCs. With the exception of RMC SCs (p < 0.0001), the differences in survival rates between the materials did not reach statistical significance. Veneered SCs showed significantly (p = 0.017) higher annual ceramic chipping rates (1.65%) compared with monolithic SCs (0.39%). The location of the SCs, anterior vs. posterior, did not influence survival and chipping rates. Conclusions With the exception of RMC SCs, veneered and monolithic implant‐supported ceramic SCs showed favorable short‐term survival and complication rates. Significantly higher rates for ceramic chipping, however, were reported for veneered compared with monolithic ceramic SCs.
Collapse
Affiliation(s)
- Bjarni Elvar Pjetursson
- Department of Reconstructive Dentistry, Faculty of Odontology, University of Iceland, Reykjavik, Iceland.,Division of Fixed Prosthodontics and Biomaterials, University Clinics for Dental Medicine, University of Geneva, Geneva, Switzerland
| | - Irena Sailer
- Division of Fixed Prosthodontics and Biomaterials, University Clinics for Dental Medicine, University of Geneva, Geneva, Switzerland
| | - Andrey Latyshev
- Division of Fixed Prosthodontics and Biomaterials, University Clinics for Dental Medicine, University of Geneva, Geneva, Switzerland.,Department of Maxillofacial, Oral and Plastic Surgery, Faculty of Dentistry, Moscow State University of Medicine and Dentistry, Moscow, Russia
| | - Kerstin Rabel
- Department of Prosthetic Dentistry, Faculty of Medicine, Center for Dental Medicine, Medical Center - University of Freiburg, Freiburg, Germany
| | - Ralf-Joachim Kohal
- Department of Prosthetic Dentistry, Faculty of Medicine, Center for Dental Medicine, Medical Center - University of Freiburg, Freiburg, Germany
| | - Duygu Karasan
- Division of Fixed Prosthodontics and Biomaterials, University Clinics for Dental Medicine, University of Geneva, Geneva, Switzerland
| |
Collapse
|
14
|
Kunrath MF, Gupta S, Lorusso F, Scarano A, Noumbissi S. Oral Tissue Interactions and Cellular Response to Zirconia Implant-Prosthetic Components: A Critical Review. MATERIALS 2021; 14:ma14112825. [PMID: 34070589 PMCID: PMC8198172 DOI: 10.3390/ma14112825] [Citation(s) in RCA: 16] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 03/24/2021] [Revised: 05/15/2021] [Accepted: 05/18/2021] [Indexed: 12/20/2022]
Abstract
Background: Dental components manufactured with zirconia (ZrO2) represent a significant percentage of the implant prosthetic market in dentistry. However, during the last few years, we have observed robust clinical and pre-clinical scientific investigations on zirconia both as a prosthetic and an implantable material. At the same time, we have witnessed consistent technical and manufacturing updates with regards to the applications of zirconia which appear to gradually clarify points which until recently were not well understood. Methods: This critical review evaluated the “state of the art” in relation to applications of this biomaterial in dental components and its interactions with oral tissues. Results: The physico-chemical and structural properties as well as the current surface treatment methodologies for ZrO2 were explored. A critical investigation of the cellular response to this biomaterial was completed and the clinical implications discussed. Finally, surface treatments of ZrO2 demonstrate that excellent osseointegration is possible and provide encouraging prospects for rapid bone adhesion. Furthermore, sophisticated surface treatment techniques and technologies are providing impressive oral soft tissue cell responses thus leading to superior biological seal. Conclusions: Dental devices manufactured from ZrO2 are structurally and chemically stable with biocompatibility levels allowing for safe and long-term function in the oral environment.
Collapse
Affiliation(s)
- Marcel F. Kunrath
- Dentistry Department, School of Health and Life Sciences, Pontifical Catholic University of Rio Grande do Sul (PUCRS), P.O. Box 6681, Porto Alegre 90619-900, RS, Brazil;
- Materials and Nanoscience Laboratory, Pontifical Catholic University of Rio Grande do Sul (PUCRS), P.O. Box 6681, Porto Alegre 90619-900, RS, Brazil
| | - Saurabh Gupta
- Zirconia Implant Research Group (Z.I.R.G), International Academy of Ceramic Implantology, Silver Spring, MD 20901, USA; (S.G.); (S.N.)
- Master Dental Science, Universitat Jaume I, 12071 Castellón de la Plana, Spain
| | - Felice Lorusso
- Department of Innovative Technologies in Medicine & Dentistry, University of Chieti-Pescara, Via dei Vestini, 31-66100 Chieti, CH, Italy;
| | - Antonio Scarano
- Zirconia Implant Research Group (Z.I.R.G), International Academy of Ceramic Implantology, Silver Spring, MD 20901, USA; (S.G.); (S.N.)
- Department of Innovative Technologies in Medicine & Dentistry, University of Chieti-Pescara, Via dei Vestini, 31-66100 Chieti, CH, Italy;
- Correspondence: ; Tel.: +08713554084
| | - Sammy Noumbissi
- Zirconia Implant Research Group (Z.I.R.G), International Academy of Ceramic Implantology, Silver Spring, MD 20901, USA; (S.G.); (S.N.)
- Department of Innovative Technologies in Medicine & Dentistry, University of Chieti-Pescara, Via dei Vestini, 31-66100 Chieti, CH, Italy;
| |
Collapse
|
15
|
Fonseca M, Molinero-Mourelle P, Forrer FA, Schnider N, Hicklin SP, Schimmel M, Brägger U. Clinical performance of implant crowns with customized zirconia abutments: A prospective cohort study with a 4.5- to 8.8-year follow-up. Clin Oral Implants Res 2021; 32:853-862. [PMID: 33949004 DOI: 10.1111/clr.13761] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/20/2020] [Revised: 04/14/2021] [Accepted: 04/22/2021] [Indexed: 11/30/2022]
Abstract
OBJECTIVE To assess the clinical and esthetic outcomes and patient satisfaction of screw-retained one-piece implant crowns fabricated with zirconia abutments after a 4.5- to 8.8-year follow-up. MATERIAL AND METHODS Thirty-two patients (12 women and 20 men), who received 40 implant single crowns in anterior and premolar sites, were included in this prospective study. All restorations were based on ceramic hand-veneered customized CAD/CAM zirconia abutments. The follow-up consisted of clinical and radiological examinations. The pink esthetic score-white esthetic score (PES-WES) was used to evaluate the esthetic outcome. Patients' satisfaction was assessed via visual analog scale (VAS). RESULTS Implant and prosthetic survival rates were 100% and 97.5%, respectively. Mean marginal bone loss was -0.17 mm (SD 1.16 mm). Probing depth was ≤4 mm in 98.7% and 5 mm in 1.3% of the sites; 8.3% of them were bleeding on probing positive. No technical or biological complications were observed except for one abutment fracture. The mean PES-WES scores were 7.0 and 7.1, respectively. VAS scores (10-point) of 9.41 for function and 9.26 for esthetics showed high patient satisfaction. CONCLUSION After a mean observation period of 6 years and 7 months, screw-retained implant crowns based on veneered customized CAD/CAM zirconia abutments with conical connection showed very good clinical performance and may be recommended for the replacement of missing anterior and premolar teeth. (ClinicalTrials.gov # NCT04370314).
Collapse
Affiliation(s)
- Manrique Fonseca
- Department of Reconstructive Dentistry and Gerodontology, School of Dental Medicine, University of Bern, Bern, Switzerland
| | - Pedro Molinero-Mourelle
- Department of Reconstructive Dentistry and Gerodontology, School of Dental Medicine, University of Bern, Bern, Switzerland
| | - Fiona Alena Forrer
- Department of Reconstructive Dentistry and Gerodontology, School of Dental Medicine, University of Bern, Bern, Switzerland
| | - Nicole Schnider
- Department of Reconstructive Dentistry and Gerodontology, School of Dental Medicine, University of Bern, Bern, Switzerland
| | - Stefan Paul Hicklin
- Clinic of Preventive Dentistry, Periodontology and Cariology, and Clinic of General, Special Care and Geriatric Dentistry, Center of Dental Medicine, University of Zurich, Zurich, Switzerland
| | - Martin Schimmel
- Department of Reconstructive Dentistry and Gerodontology, School of Dental Medicine, University of Bern, Bern, Switzerland.,Privat-docent extra muros, Division of Gerodontology and Removable Prosthodontics, University Clinics of Dental Medicine, University of Geneva, Geneva, Switzerland
| | - Urs Brägger
- Department of Reconstructive Dentistry and Gerodontology, School of Dental Medicine, University of Bern, Bern, Switzerland
| |
Collapse
|
16
|
Häfner SJ. High hopes and high honours for cancer immunotherapy. Biomed J 2019; 42:293-298. [PMID: 31783989 PMCID: PMC6889242 DOI: 10.1016/j.bj.2019.10.001] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/12/2019] [Accepted: 10/14/2019] [Indexed: 02/07/2023] Open
Abstract
This issue of the Biomedical Journal honours the laureates of the 2018 Nobel Prize in Physiology and Medicine for their ground-breaking contributions to cancer immunotherapy and unveils the identification of essential intermediates between microtubule-targeting agents and apoptosis. Subsequently, we learn about the hypoglycemic properties of natural phenolic acids, how cone-beam computed tomography assists dental implant surgery and which factors should be taken into account for salvage liver transplantation after recurrent hepatocellular carcinoma. Further readings discuss the negative impact of bismuth shields on computed tomography image quality, the predictive value of warning headaches for aneurysmal subarachnoid haemorrhage and the great long-term performance of zirconia implant abutments.
Collapse
Affiliation(s)
- Sophia Julia Häfner
- University of Copenhagen, BRIC Biotech Research & Innovation Centre, Anders Lund Group, Ole Maaløes Vej 5, 2200 Copenhagen, Denmark.
| |
Collapse
|
17
|
Nilsson A, Johansson L, Stenport VF, Wennerberg A, Ekfeldt A. Infraposition of anterior maxillary implant‐supported single‐tooth restorations in adolescent and adult patients—A prospective follow‐up study up to 6 years. Clin Implant Dent Relat Res 2019; 21:953-959. [DOI: 10.1111/cid.12818] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/05/2019] [Revised: 05/31/2019] [Accepted: 06/16/2019] [Indexed: 12/26/2022]
Affiliation(s)
- Andrée Nilsson
- Division of Prosthetic Dentistry, Maxillofacial UnitHalmstad Hospital Halmstad Sweden
- Department of Prosthodontics/Dental materials science, Institute of Odontology, Sahlgrenska AcademyGöteborg University Sweden
| | - Lars‐åke Johansson
- Division of Prosthetic Dentistry, Maxillofacial UnitHalmstad Hospital Halmstad Sweden
- Department of Periodontology, Faculty of OdontologyMalmö University Malmö Sweden
| | - Victoria F. Stenport
- Department of Prosthodontics/Dental materials science, Institute of Odontology, Sahlgrenska AcademyGöteborg University Sweden
| | - Ann Wennerberg
- Department of Prosthodontics/Dental materials science, Institute of Odontology, Sahlgrenska AcademyGöteborg University Sweden
| | - Anders Ekfeldt
- Department of Prosthetic Dentistry and Oral Function, Faculty of Dentistry, Institute of Clinical DentistryUniversity of Oslo Oslo Norway
| |
Collapse
|
18
|
Fatigue survival and failure resistance of titanium versus zirconia implant abutments with various connection designs. J Prosthet Dent 2019; 122:315.e1-315.e7. [PMID: 31326150 DOI: 10.1016/j.prosdent.2019.05.036] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/09/2019] [Revised: 05/27/2019] [Accepted: 05/28/2019] [Indexed: 11/24/2022]
Abstract
STATEMENT OF PROBLEM Data regarding the effect of connection design and abutment material on the fatigue survival and failure resistance of implant abutments are scarce. PURPOSE The purpose of this in vitro study was to investigate the effect of connection design and abutment material on the fatigue survival and failure resistance of implant abutment assemblies. MATERIAL AND METHODS Three types of implants (n=18, N=54) and 6 groups of abutments (n=9, N=54) with different connection designs-internal conical (IC), internal tri-channel (IT), and external hexagonal (EH)-and abutment materials-titanium (T) and zirconia (Z)-were investigated. All the abutments were restored with identical central incisor crowns. Fatigue testing, including thermal and mechanical aging, was performed in a mastication simulator (Esetron Smart Robotechnologies) for up to 1.2×106 cycles with a load of 50 N at an angle of 45 degrees. Then, the surviving specimens were subjected to failure resistance testing in a universal testing machine (Shimadzu AG-IS; Shimadzu Corp) at a crosshead speed of 1.0 mm/min. The maximum loads to failure (N) were recorded. Survival performance of the specimens throughout the fatigue testing was examined by the Kaplan-Meier survival analysis. The failure loads were analyzed by using the Kruskal-Wallis test followed by the Mann-Whitney U tests with Bonferroni-Holm correction (α=.05). RESULTS All the specimens of groups ICT, ITT, ITZ, and EHT survived fatigue testing, whereas 2 specimens from group ICZ and 3 specimens from EHZ failed. Statistically significant differences were found among the groups, based on the results of maximum failure loads (P<.05). The highest mean failure load was obtained in the ICT group (1069 ±182 N), followed by the ITT (926 ±197 N), EHT (873 ±126 N), ITZ (568 ±81 N), EHZ (311 ±45 N), and ICZ (287 ±63 N) groups. CONCLUSIONS Abutment material and connection design affected the fatigue survival of implant abutment assemblies. Implant abutment assemblies with a titanium-titanium interface revealed higher failure resistance than the implant abutment assemblies with a titanium-zirconia interface.
Collapse
|
19
|
Asgeirsson AG, Sailer I, Gamper F, Jung RE, Hämmerle CHF, Thoma DS. Veneered zirconia abutments cemented on non‐original titanium bases: 1‐year results of a prospective case series. Clin Oral Implants Res 2019; 30:735-744. [DOI: 10.1111/clr.13457] [Citation(s) in RCA: 10] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/21/2018] [Revised: 03/29/2019] [Accepted: 03/29/2019] [Indexed: 12/29/2022]
Affiliation(s)
- Asgeir G. Asgeirsson
- Clinic of Fixed and Removable Prosthodontics and Dental Material Science, Center of Dental Medicine University of Zurich Zurich Switzerland
| | - Irena Sailer
- Division of Fixed Prosthodontics and Biomaterials University Clinic of Dental Medicine, University of Geneva Geneva Switzerland
| | - Felix Gamper
- Clinic of Fixed and Removable Prosthodontics and Dental Material Science, Center of Dental Medicine University of Zurich Zurich Switzerland
| | - Ronald E. Jung
- Clinic of Fixed and Removable Prosthodontics and Dental Material Science, Center of Dental Medicine University of Zurich Zurich Switzerland
| | - Christoph H. F. Hämmerle
- Clinic of Fixed and Removable Prosthodontics and Dental Material Science, Center of Dental Medicine University of Zurich Zurich Switzerland
| | - Daniel S. Thoma
- Clinic of Fixed and Removable Prosthodontics and Dental Material Science, Center of Dental Medicine University of Zurich Zurich Switzerland
| |
Collapse
|
20
|
Kraus RD, Epprecht A, Hämmerle CH, Sailer I, Thoma DS. Cemented vs screw-retained zirconia-based single implant reconstructions: A 3-year prospective randomized controlled clinical trial. Clin Implant Dent Relat Res 2019; 21:578-585. [DOI: 10.1111/cid.12735] [Citation(s) in RCA: 14] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/21/2018] [Revised: 01/08/2019] [Accepted: 01/11/2019] [Indexed: 12/11/2022]
Affiliation(s)
- Riccardo D. Kraus
- Clinic of Fixed and Removable Prosthodontics and Dental Material Science, Center of Dental Medicine; University of Zurich; Zurich Switzerland
| | - Alyssa Epprecht
- Clinic of Fixed and Removable Prosthodontics and Dental Material Science, Center of Dental Medicine; University of Zurich; Zurich Switzerland
| | - Christoph H.F. Hämmerle
- Clinic of Fixed and Removable Prosthodontics and Dental Material Science, Center of Dental Medicine; University of Zurich; Zurich Switzerland
| | - Irena Sailer
- Division of Fixed Prosthodontics and Biomaterials; University Clinics for Dental Medicine, University of Geneva; Geneva Switzerland
| | - Daniel S. Thoma
- Clinic of Fixed and Removable Prosthodontics and Dental Material Science, Center of Dental Medicine; University of Zurich; Zurich Switzerland
| |
Collapse
|
21
|
Doornewaard R, Jacquet W, Cosyn J, De Bruyn H. How do peri-implant biologic parameters correspond with implant survival and peri-implantitis? A critical review. Clin Oral Implants Res 2019; 29 Suppl 18:100-123. [PMID: 30306697 PMCID: PMC6220966 DOI: 10.1111/clr.13264] [Citation(s) in RCA: 60] [Impact Index Per Article: 10.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/08/2018] [Revised: 04/02/2018] [Accepted: 04/11/2018] [Indexed: 02/06/2023]
Abstract
Objectives The aim of this critical review was to evaluate whether commonly used biologic diagnostic parameters correspond to implant survival and peri‐implantitis prevalence. Materials and methods Publications from 2011 to 2017 were selected by an electronic search using the Pubmed database of the US National Library of Medicine. Prospective and retrospective studies with a mean follow‐up time of at least 5 years and reporting prevalence of peri‐implantitis as well as mean bone loss and standard deviation were selected. The correlation between reported prevalence of peri‐implantitis and reported implant survival, mean follow‐up time, mean bone loss, mean probing depth, and mean bleeding on probing was calculated. Mean bone loss and standard deviation were used for estimation of proportion of implants with bone loss exceeding 1, 2, and 3 mm. Results Full‐text analysis was performed for 255 papers from 4,173 available ones, and 41 met all the inclusion criteria. The overall mean weighted survival rate was 96.9% (89.9%–100%) and the reported prevalence of peri‐implantitis ranged between 0% and 39.7%, based on 15 different case definitions. The overall weighted bone loss was 1.1 mm based on 8,182 implants and an average mean loading time ranging from 5 to 20 years. No correlation was found between mean bone loss and the reported prevalence of peri‐implantitis. The estimated prevalence of implants with bone loss above 2 mm was 23%. The overall weighted mean probing depth was 3.3 mm, and mean weighted bleeding was 52.2%. Only a weak correlation was found between survival and function time (r = −0.49). There was no relation between the probing depth or bleeding and the mean bone loss, mean follow‐up time, and reported prevalence of peri‐implantitis. Conclusion Biologic parameters mean probing depth and mean bleeding on probing do not correlate with mean bone loss and this irrespective of follow‐up. Case definition for peri‐implantitis varied significantly between studies indicating that an unambiguous definition based on a specified threshold for bone loss is not agreed upon in the literature.
Collapse
Affiliation(s)
- Ron Doornewaard
- Department Periodontology & Oral Implantology, Dental School, Faculty Medicine and Health Sciences, Ghent University Belgium, Ghent, Belgium
| | - Wolfgang Jacquet
- Department Periodontology & Oral Implantology, Dental School, Faculty Medicine and Health Sciences, Ghent University Belgium, Ghent, Belgium.,Oral Health Research Group ORHE, Faculty of Medicine and Pharmacy, Vrije Universiteit Brussel, Brussels, Belgium.,Department of Educational Sciences EDWE-LOCI, Faculty of Psychology and Educational Sciences, Vrije Universiteit Brussel, Brussels, Belgium
| | - Jan Cosyn
- Department Periodontology & Oral Implantology, Dental School, Faculty Medicine and Health Sciences, Ghent University Belgium, Ghent, Belgium.,Oral Health Research Group ORHE, Faculty of Medicine and Pharmacy, Vrije Universiteit Brussel, Brussels, Belgium
| | - Hugo De Bruyn
- Department Periodontology & Oral Implantology, Dental School, Faculty Medicine and Health Sciences, Ghent University Belgium, Ghent, Belgium.,Section Implantology & Periodontology, Department of Dentistry, Radboudumc, Nijmegen, The Netherlands
| |
Collapse
|
22
|
Sanz-Sánchez I, Sanz-Martín I, Carrillo de Albornoz A, Figuero E, Sanz M. Biological effect of the abutment material on the stability of peri-implant marginal bone levels: A systematic review and meta-analysis. Clin Oral Implants Res 2018; 29 Suppl 18:124-144. [DOI: 10.1111/clr.13293] [Citation(s) in RCA: 39] [Impact Index Per Article: 5.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/27/2018] [Revised: 05/05/2018] [Accepted: 05/08/2018] [Indexed: 12/25/2022]
Affiliation(s)
- Ignacio Sanz-Sánchez
- Section of Graduate Periodontology; University Complutense; Madrid Spain
- ETEP (Etiology and Therapy of Periodontal Diseases) Research Group; University Complutense; Madrid Spain
| | | | | | - Elena Figuero
- Section of Graduate Periodontology; University Complutense; Madrid Spain
- ETEP (Etiology and Therapy of Periodontal Diseases) Research Group; University Complutense; Madrid Spain
| | - Mariano Sanz
- Section of Graduate Periodontology; University Complutense; Madrid Spain
- ETEP (Etiology and Therapy of Periodontal Diseases) Research Group; University Complutense; Madrid Spain
| |
Collapse
|
23
|
Øilo M, Arola D. Fractographic analyses of failed one-piece zirconia implant restorations. Dent Mater 2018; 34:922-931. [PMID: 29673708 DOI: 10.1016/j.dental.2018.03.018] [Citation(s) in RCA: 12] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/29/2017] [Revised: 10/19/2017] [Accepted: 03/23/2018] [Indexed: 02/06/2023]
Abstract
BACKGROUND Promising results of initial clinical trials with yttria-stabilized zirconia have led to more extensive use of zirconia in dental implant superstructures. The applications have extended to abutments and complex individually designed crown-abutment one-piece structures. Little is known about their clinical success and the primary cause of failures. PURPOSE The aim of this study was to identify the cause of fracture of retrieved implant-retained one-piece prostheses that failed during clinical use. METHODS Nine fractured restorations were analyzed with fractographic methods and their fracture origins were identified. RESULTS All but two of the fractures originated in an area of tight contact between the implant or titanium screw and the abutment base. Results of the evaluation showed that zirconia-based implant restorations with very thin walls in the region connecting the prosthesis to the implant are vulnerable to damage from the screw retaining process and fracture from non-axial loads. Two restorations failed due to veneer fractures. SIGNIFICANCE The findings suggest that large crowns on narrow implants or implants with internal fixation should preferably not be made with zirconia abutments, or that a new design approach should be considered.
Collapse
Affiliation(s)
- Marit Øilo
- Department of Clinical Dentistry, Faculty of Medicine and Dentistry, University of Bergen, Norway; Department of Materials Science and Engineering, University of Washington Seattle, WA, USA.
| | - Dwayne Arola
- Department of Materials Science and Engineering, University of Washington Seattle, WA, USA; Departments of Oral Health Sciences, School of Dentistry, University of Washington, Seattle, WA, USA; Departments of Restorative Dentistry, School of Dentistry, University of Washington, Seattle, WA, USA
| |
Collapse
|
24
|
Nilsson A, Johansson LÅ, Lindh C, Ekfeldt A. One-piece internal zirconia abutments for single-tooth restorations on narrow and regular diameter implants: A 5-year prospective follow-up study. Clin Implant Dent Relat Res 2017; 19:916-925. [DOI: 10.1111/cid.12515] [Citation(s) in RCA: 21] [Impact Index Per Article: 2.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/05/2017] [Revised: 05/26/2017] [Accepted: 06/10/2017] [Indexed: 12/11/2022]
Affiliation(s)
- Andrée Nilsson
- Division of Prosthetic Dentistry; Maxillofacial Unit, Halmstad Hospital; Halmstad Sweden
| | - Lars-Åke Johansson
- Division of Prosthetic Dentistry; Maxillofacial Unit, Halmstad Hospital; Halmstad Sweden
- Department of Periodontology, Faculty of Odontology; Malmö University; Malmö Sweden
| | - Christina Lindh
- Department of Oral Radiology, Faculty of Odontology; Malmö University; Malmö Sweden
| | - Anders Ekfeldt
- Department of Prosthetic Dentistry and Oral Function, Faculty of Dentistry, Institute of Clinical Dentistry; University of Oslo; Oslo Norway
| |
Collapse
|