1
|
Chiang CC, Li JS, Wan HH, Ren F, Esquivel-Upshaw JF. Fabrication of TiO 2 Nanotube Arrays by Progressive Anodization of Ti Thin Film on Insulated Substrates. MATERIALS (BASEL, SWITZERLAND) 2025; 18:1219. [PMID: 40141501 PMCID: PMC11943509 DOI: 10.3390/ma18061219] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 12/16/2024] [Revised: 03/02/2025] [Accepted: 03/03/2025] [Indexed: 03/28/2025]
Abstract
Titanium (Ti) thin films deposited on insulated substrates were progressively anodized and formed titanium dioxide (TiO2) nanotube arrays on the surface through a customized anodization tool designed to improve the uniformity and diameters of the nanotubes. With a motorized vertical moving arm attached to the anode, the sample was gradually submerged into the electrolyte at a controlled speed alongside the continuous anodization from the edge to the center to prevent the discontinuation of the conductive Ti layer and its nanotube surface. The effects of Ti deposition rate, anodization voltage, NH4F concentration, and post-etching conditions on nanotube morphology were also explored. Scanning electron microscopy (SEM) analysis revealed that smaller Ti grain sizes, higher anodization voltages, higher electrolyte concentrations, and optimized post-etching times produce uniform, mature nanotubes with larger diameters, which are crucial for practical applications. This work enhances the applicability of nanotube surfaces with non-conductive substrates, such as Zirconia dental implants, and establishes a foundation for future process optimizations.
Collapse
Affiliation(s)
- Chao-Ching Chiang
- Department of Chemical Engineering, College of Engineering, University of Florida, Gainesville, FL 32611, USA; (C.-C.C.); (J.-S.L.); (H.-H.W.); (F.R.)
| | - Jian-Sian Li
- Department of Chemical Engineering, College of Engineering, University of Florida, Gainesville, FL 32611, USA; (C.-C.C.); (J.-S.L.); (H.-H.W.); (F.R.)
| | - Hsiao-Hsuan Wan
- Department of Chemical Engineering, College of Engineering, University of Florida, Gainesville, FL 32611, USA; (C.-C.C.); (J.-S.L.); (H.-H.W.); (F.R.)
| | - Fan Ren
- Department of Chemical Engineering, College of Engineering, University of Florida, Gainesville, FL 32611, USA; (C.-C.C.); (J.-S.L.); (H.-H.W.); (F.R.)
| | - Josephine F. Esquivel-Upshaw
- Department of Restorative Dental Sciences, Division of Prosthodontics, College of Dentistry, University of Florida, Gainesville, FL 32610, USA
| |
Collapse
|
2
|
Ruiz Henao PA, Magrin GL, Caneiro-Queija L, Benfatti CAM, Leira Y, Liñares-González A, Blanco-Carrión J. Single-piece zirconia versus single-piece titanium, narrow-diameter dental implants in the anterior maxilla: 5-year post-loading results of a randomized clinical trial. Clin Oral Implants Res 2024; 35:1310-1323. [PMID: 38940623 DOI: 10.1111/clr.14319] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/01/2023] [Revised: 05/20/2024] [Accepted: 06/02/2024] [Indexed: 06/29/2024]
Abstract
OBJECTIVES The aim of this study was to evaluate esthetic parameters in the anterior maxillary region by comparing single-piece zirconia versus titanium narrow-diameter implants. Additionally, clinical, radiological and patient-reported outcome measures (PROMs) were analyzed. MATERIALS AND METHODS Thirty implants (tissue level implant) were placed in 30 patients in the maxillary esthetic sector. Depending on randomization, a zirconia (test) or titanium implant (control) was placed. Esthetic, clinical, and radiological parameters, including the implant crown esthetic index (ICAI), pink esthetic score (PES), probing pocket depth, bleeding on probing, plaque index, and marginal bone levels, were evaluated at 12, 36 and 60 months after loading. RESULTS Sixty months after crown placement, no significant differences were found between groups. The ICAI values were 5.25 ± 4.21 and 4.50 ± 2.98 for the test and control groups, respectively. The corresponding PES values were 7.44 ± 1.93 and 7.43 ± 1.74 for the test and control groups, respectively. There were no significant intergroup differences for the rest of the parameters evaluated. CONCLUSION It can be suggested that monotype zirconia implants may serve as a potential alternative to titanium implants in selected clinical scenarios. While the results demonstrated comparable esthetic, clinical, and radiological aspects for zirconia implants as compared to titanium implants after a 5-year follow-up period, further research with larger sample sizes and longer-term follow-up is recommended.
Collapse
Affiliation(s)
- Paula Andrea Ruiz Henao
- Unit of Periodontology, Department of Surgery and Medical-Surgical Specialties, Faculty of Medicine and Dentistry, University of Santiago de Compostela, Santiago de Compostela, Spain
| | - Gabriel Leonardo Magrin
- Unit of Periodontology, Department of Surgery and Medical-Surgical Specialties, Faculty of Medicine and Dentistry, University of Santiago de Compostela, Santiago de Compostela, Spain
- Center for Education and Research on Dental Implants (CEPID), Department of Dentistry, Federal University of Santa Catarina (UFSC), Florianópolis, Brazil
| | - Leticia Caneiro-Queija
- Unit of Periodontology, Department of Surgery and Medical-Surgical Specialties, Faculty of Medicine and Dentistry, University of Santiago de Compostela, Santiago de Compostela, Spain
| | - Cesar Augusto Magalhães Benfatti
- Center for Education and Research on Dental Implants (CEPID), Department of Dentistry, Federal University of Santa Catarina (UFSC), Florianópolis, Brazil
| | - Yago Leira
- Unit of Periodontology, Department of Surgery and Medical-Surgical Specialties, Faculty of Medicine and Dentistry, University of Santiago de Compostela, Santiago de Compostela, Spain
| | - Antonio Liñares-González
- Unit of Periodontology, Department of Surgery and Medical-Surgical Specialties, Faculty of Medicine and Dentistry, University of Santiago de Compostela, Santiago de Compostela, Spain
| | - Juan Blanco-Carrión
- Unit of Periodontology, Department of Surgery and Medical-Surgical Specialties, Faculty of Medicine and Dentistry, University of Santiago de Compostela, Santiago de Compostela, Spain
| |
Collapse
|
3
|
Mohseni P, Soufi A, Chrcanovic BR. Clinical outcomes of zirconia implants: a systematic review and meta-analysis. Clin Oral Investig 2023; 28:15. [PMID: 38135804 PMCID: PMC10746607 DOI: 10.1007/s00784-023-05401-8] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/18/2023] [Accepted: 12/04/2023] [Indexed: 12/24/2023]
Abstract
PURPOSE To assess the clinical outcomes of zirconia dental implants based on an updated systematic literature review. METHODS An electronic search was performed in three databases, last updated in June 2023, supplemented by hand searching. The eligibility criteria were clinical studies reporting patients rehabilitated with zirconia implants. The cumulative survival rate (CSR) of implants was calculated. A meta-analysis for marginal bone loss (MBL) under different follow-up times and a meta-regression assessing the relationship between mean MBL and follow-up were done. RESULTS Twenty-five studies were included (4017 implants, 2083 patients). Seven studies had follow-up longer than 60 months. 172 implants failed, after a mean of 12.0 ± 16.1 months (min-max 0.3-86.0), of which 47 early failures, and 26 due to implant fracture, the majority in narrow-diameter implants. The 10-year CSR was 95.1%. Implants with coronal part prepared by drills presented statistically significant lower survival than non-prepared implants (p < 0.001). Two-piece implants presented lower survival than one-piece implants (p = 0.017). Implants discontinued from the market presented lower survival than the commercially available ones (p < 0.001). The difference in survival was not significant between implants in maxilla and mandible (p = 0.637). The mean MBL fluctuated between 0.632 and 2.060 mm over long periods of observation (up until 132 months). There was an estimated MBL increase of 0.005 mm per additional month of follow-up. CONCLUSION Zirconia implants present high 10-year CSR and short-term low MBL. The review was registered in PROSPERO (CRD42022342055). CLINICAL RELEVANCE The clinical outcomes observed for zirconia dental implants are very promising, although these have not yet been extensively studied as titanium alloy implants.
Collapse
Affiliation(s)
| | - Ahmad Soufi
- Faculty of Odontology, Malmö University, Malmö, Sweden
| | - Bruno Ramos Chrcanovic
- Department of Oral and Maxillofacial Surgery and Oral Medicine, Faculty of Odontology, Malmö University, Carl Gustafs Väg 34, 214 21, Malmö, Sweden.
| |
Collapse
|
4
|
Peng M, Chuan JL, Zhao GP, Fu Q. Construction of silver-coated high translucent zirconia implanting abutment material and its property of antibacterial. ARTIFICIAL CELLS, NANOMEDICINE, AND BIOTECHNOLOGY 2023; 51:441-452. [PMID: 37594201 DOI: 10.1080/21691401.2023.2244013] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 03/17/2023] [Revised: 07/13/2023] [Accepted: 07/29/2023] [Indexed: 08/19/2023]
Abstract
High translucent zirconia (HTZ) has excellent mechanical properties, biocompatibility, and good semi-translucency making it an ideal material for aesthetic anterior dental implant abutments without antibacterial properties. In the oral environment, the surface of the abutment material is susceptible to microbial adhesion and biofilm formation, which can lead to infection or peri-implantitis and even implant failure. This study aims to promote the formation of a biological seal at the implant-soft tissue interface by modifying the HTZ surface, using the load-bearing capacity of the aluminosilicate porous structure and the broad-spectrum antibacterial effect of silver nanoparticles to prevent peri-implant bacterial infection and inflammation and to improve the success rate and prolong the use of the implant. FE-SEM (field emission scanning electron microscopes), EDS (energy dispersive spectroscopy), and XPS (X-ray photoelectron spectroscopy) results showed that aluminosilicate non-vacuum sintering can form open micro- and nanoporous structures on HTZ surfaces, and that porous aluminosilicate coatings obtain a larger number, smaller size, and more uniformly shaped silver nanoparticles than smooth aluminosilicate coatings, and could be deposited deeper in the coating. The ICP-AES (inductively coupled plasma-atomic emission spectroscopy) results showed that the early silver ion release of both the smooth silver coating and the porous silver coating was obvious, the silver ion concentration released by the former was higher than that of the latter. However, the silver ion concentration released by the porous silver coating was higher than that of the smooth coating when the release slowed down. Both smooth and porous silver coatings both inhibited E. coli (Escherichia coli), S. aureus (Staphylococcus aureus), and L. acidophilus (L. acidophilus), and porous silver coatings had stronger antibacterial properties. The silver coating was successfully constructed on the surface of HTZ, through aluminium silicate sintering and silver nitrate solution impregnation. It was found that the high concentration environment of silver nitrate solution was more advantageous for nano-Ag deposition, and the non-vacuum sintered porous surface was able to obtain a larger number of nano-Ag particles with smaller sizes. The porous Ag coating exhibited superior antibacterial properties. It was suggested that the HTZ with silver coating had clinical application, and good antibacterial properties that can improve the survival rate and service life of implants.
Collapse
Affiliation(s)
- Min Peng
- Department of Stomatology, Sichuan Academy of Medical Sciences and Sichuan Provincial People's Hospital, Chengdu, Sichuan, China
- School of Medicine, University of Electronic Science and Technology of Chengdu, Sichuan, China
| | - Jun-Lan Chuan
- Department of Pharmacy, Sichuan Academy of Medical Sciences and Sichuan Provincial People's Hospital, School of Medicine, University of Electronic Science and Technology of China, Chengdu, Sichuan, China
| | - Gao-Ping Zhao
- Department of Gastroinstestinal Surgery, Sichuan Academy of medical sciences and Sichuan Provincial People's Hospital, University of Medical sciences and technology of China, Chengdu, Sichuan, China
| | - Qiang Fu
- Organ Transplantation Center, Sichuan Provincial People's Hospital, School of Medicine, University of Electronic Science and Technology of China, Chengdu, China
| |
Collapse
|
5
|
Padhye NM, Calciolari E, Zuercher AN, Tagliaferri S, Donos N. Survival and success of zirconia compared with titanium implants: a systematic review and meta-analysis. Clin Oral Investig 2023; 27:6279-6290. [PMID: 37740825 PMCID: PMC10630218 DOI: 10.1007/s00784-023-05242-5] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/11/2022] [Accepted: 09/05/2023] [Indexed: 09/25/2023]
Abstract
OBJECTIVE This systematic review assessed the available evidence on the survival and success rate of zirconia and titanium implants. As secondary outcomes, aesthetic, radiographic and clinical parameters, as well as biological and mechanical complications, were considered. MATERIALS AND METHODS A systematic search was performed up to March 2022 to identify CCTs/RCTs comparing zirconia and titanium implants with a minimum of 12 months of follow-up. Meta-analysis was performed when ≥ 2 articles with similar characteristics were retrieved. RESULTS Four published articles with two RCTs (2 different patient populations) with 100 zirconia and 99 titanium implants that were followed up over 12-80 months were selected out of the 6040 articles. A non-statistically significant difference between zirconia and titanium implant survival at 12 months was suggested (P = 0.0938). The success rates were 57.5-93.3% and 57.1-100% for zirconia and titanium implants, respectively. The pink aesthetic score (PES) was higher for zirconia (10.33 ± 2.06 to 11.38 ± 0.92) compared to titanium implants (8.14 ± 3.58 to 11.56 ± 1.0). CONCLUSION Based on the 2 RCTs retrieved in the literature, similar survival rates were reported for zirconia and titanium implants in the short term (12 months of follow-up). Future RCTs are warranted to evaluate the long-term outcomes of zirconia implants. CLINICAL RELEVANCE Zirconia implants may be the procedure of choice, particularly in the aesthetic zone, since they show a similar survival and success rate as titanium implants on a short-term follow-up. TRIAL REGISTRATION Systematic review registration number-CRD42021288704 (PROSPERO).
Collapse
Affiliation(s)
- Ninad Milind Padhye
- Centre for Oral Clinical Research, Institute of Dentistry, Faculty of Medicine and Dentistry, Queen Mary University of London (QMUL), London, UK
| | - Elena Calciolari
- Centre for Oral Clinical Research, Institute of Dentistry, Faculty of Medicine and Dentistry, Queen Mary University of London (QMUL), London, UK
- Department of Medicine and Surgery, Centre of Dentistry, University of Parma, Parma, Italy
| | - Anina Nives Zuercher
- Centre for Oral Clinical Research, Institute of Dentistry, Faculty of Medicine and Dentistry, Queen Mary University of London (QMUL), London, UK
- Clinic of Reconstructive Dentistry, Centre of Dental Medicine, Zurich, Switzerland
| | - Sara Tagliaferri
- Department of Medicine and Surgery, University of Parma, Parma, Italy
- Center of Excellence for Toxicological Research, CERT, University of Parma, Parma, Italy
| | - Nikos Donos
- Centre for Oral Clinical Research, Institute of Dentistry, Faculty of Medicine and Dentistry, Queen Mary University of London (QMUL), London, UK.
| |
Collapse
|
6
|
Kohal RJ, Vach K, Butz F, Spies BC, Patzelt SBM, Burkhardt F. One-Piece Zirconia Oral Implants for the Support of Three-Unit Fixed Dental Prostheses: Three-Year Results from a Prospective Case Series. J Funct Biomater 2023; 14:jfb14010045. [PMID: 36662092 PMCID: PMC9864364 DOI: 10.3390/jfb14010045] [Citation(s) in RCA: 2] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/22/2022] [Revised: 01/09/2023] [Accepted: 01/11/2023] [Indexed: 01/15/2023] Open
Abstract
The objective was to investigate the clinical and radiological outcome of one-piece zirconia oral implants to support three-unit fixed dental prostheses (FDP) after three years in function. Twenty-seven patients were treated with a total of 54 implants in a one-stage surgery and immediate provisionalization. Standardized radiographs were taken at implant placement, after one year and after three years, to evaluate peri-implant bone loss. Soft-tissue parameters were also assessed. Linear mixed regression models as well as Wilcoxon Signed Rank tests were used for analyzing differences between groups and time points (p < 0.05). At the three-year evaluation, one implant was lost, resulting in a cumulative survival rate of 98.1%. The mean marginal bone loss amounted to 2.16 mm. An implant success grade I of 52% (bone loss of ≤2 mm) and success grade II of 61% (bone loss of ≤3 mm) were achieved. None of the evaluated baseline parameters affected bone loss. The survival rate of the zirconia implants was comparable to market-available titanium implants. However, an increased marginal bone loss was observed with a high peri-implantitis incidence and a resulting low implant success rate.
Collapse
Affiliation(s)
- Ralf-Joachim Kohal
- Department of Prosthetic Dentistry, Faculty of Medicine, Center for Dental Medicine, Medical Center-University of Freiburg, University of Freiburg, Hugstetter Str. 55, 79106 Freiburg, Germany
- Correspondence:
| | - Kirstin Vach
- Institute of Medical Biometry and Statistics, Faculty of Medicine, Medical Center-University of Freiburg, University of Freiburg, Zinkmattenstr. 6a, 79108 Freiburg, Germany
| | - Frank Butz
- Department of Prosthetic Dentistry, Faculty of Medicine, Center for Dental Medicine, Medical Center-University of Freiburg, University of Freiburg, Hugstetter Str. 55, 79106 Freiburg, Germany
- Private Dental Clinic, Belchenstr. 6a, 79189 Bad Krozingen, Germany
| | - Benedikt Christopher Spies
- Department of Prosthetic Dentistry, Faculty of Medicine, Center for Dental Medicine, Medical Center-University of Freiburg, University of Freiburg, Hugstetter Str. 55, 79106 Freiburg, Germany
| | - Sebastian Berthold Maximilian Patzelt
- Department of Prosthetic Dentistry, Faculty of Medicine, Center for Dental Medicine, Medical Center-University of Freiburg, University of Freiburg, Hugstetter Str. 55, 79106 Freiburg, Germany
- Private Dental Clinic, Am Dorfplatz 3, 78658 Zimmern ob Rottweil, Germany
| | - Felix Burkhardt
- Department of Prosthetic Dentistry, Faculty of Medicine, Center for Dental Medicine, Medical Center-University of Freiburg, University of Freiburg, Hugstetter Str. 55, 79106 Freiburg, Germany
| |
Collapse
|
7
|
The evaluation of prepared microstructure pattern by carbon-dioxide laser on zirconia-based ceramics for dental implant application: an in vitro study. Odontology 2022:10.1007/s10266-022-00781-x. [DOI: 10.1007/s10266-022-00781-x] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/08/2022] [Accepted: 11/12/2022] [Indexed: 12/24/2022]
|
8
|
Thangavel M, Elsen Selvam R. Review of Physical, Mechanical, and Biological Characteristics of 3D-Printed Bioceramic Scaffolds for Bone Tissue Engineering Applications. ACS Biomater Sci Eng 2022; 8:5060-5093. [PMID: 36415173 DOI: 10.1021/acsbiomaterials.2c00793] [Citation(s) in RCA: 14] [Impact Index Per Article: 4.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/24/2022]
Abstract
This review focuses on the advancements in additive manufacturing techniques that are utilized for fabricating bioceramic scaffolds and their characterizations leading to bone tissue regeneration. Bioscaffolds are made by mimicking the human bone structure, material composition, and properties. Calcium phosphate apatite materials are the most commonly used scaffold materials as they closely resemble live bone in their inorganic composition. The functionally graded scaffolds are fabricated by utilizing the right choice of the 3D printing method and material combinations to achieve the requirement of the bioscaffold. To tailor the physical, mechanical, and biological properties of the scaffold, certain materials are reinforced, doped, or coated to incorporate the functionality. The biomechanical loading conditions that involve flexion, torsion, and tension exerted on the implanted scaffold are discussed. The finite element analysis (FEA) technique is used to investigate the mechanical property of the scaffold before fabrication. This helps in reducing the actual number of samples used for testing. The FEA simulated results and the experimental result are compared. This review also highlights some of the challenges associated while processing the scaffold such as shrinkage, mechanical instability, cytotoxicity, and printability. In the end, the new materials that are evolved for tissue engineering applications are compiled and discussed.
Collapse
Affiliation(s)
- Mahendran Thangavel
- School of Mechanical Engineering, Vellore Institute of Technology, Vellore, Tamil Nadu 632014, India
| | - Renold Elsen Selvam
- School of Mechanical Engineering, Vellore Institute of Technology, Vellore, Tamil Nadu 632014, India
| |
Collapse
|
9
|
Thiem DGE, Stephan D, Kniha K, Kohal RJ, Röhling S, Spies BC, Stimmelmayr M, Grötz KA. German S3 guideline on the use of dental ceramic implants. Int J Implant Dent 2022; 8:43. [PMID: 36190587 PMCID: PMC9530079 DOI: 10.1186/s40729-022-00445-z] [Citation(s) in RCA: 6] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/10/2022] [Accepted: 09/27/2022] [Indexed: 01/18/2023] Open
Abstract
PURPOSE Based on the excellent long-term data, dental implants made of titanium are considered the international implantological standard for replacing missing teeth. However, ceramic implants made of zirconia (ZrO2) have experienced a renaissance in the last 15 years due to constant innovations in materials and products, with material properties and soft tissue- and osseointegration behavior comparable to those of titanium. However, one limitation concerning ceramic implants is the lack of reliable long-term data, especially in the case of two-piece implant systems. As there is an increasing demand for ceramic implants from practitioners and patients, the German Society for Implantology (DGI) has decided to develop a guideline on the use of dental ceramic implants at the highest available evidence level with the involvement of experts in this field. METHODS Statements and recommendations were prepared after conducting a systematic literature search and an independent assessment process involving the relevant clinical literature from 2008 to 2021. The adopted recommendations and statements are summarized in this guideline. RESULTS AND CONCLUSIONS It confirms the feasible use of one-piece zirconia implants as an addendum/alternative to titanium implants. No final conclusion regarding the application of two-piece ceramic implant systems could be drawn on the basis of the existing data, thus its use can only be recommended after the patient has been informed in detail about the lack of long-term clinical data.
Collapse
Affiliation(s)
- D. G. E. Thiem
- grid.410607.4Department of Oral and Maxillofacial Surgery, Facial Plastic Surgery, University Medical Centre Mainz, Augustusplatz 2, 55131 Mainz, Germany
| | - D. Stephan
- grid.410607.4Department of Oral and Maxillofacial Surgery, Facial Plastic Surgery, University Medical Centre Mainz, Augustusplatz 2, 55131 Mainz, Germany
| | - K. Kniha
- Private Practice for Oral Surgery and Implantology, Rosental 6, 80331 Munich, Germany
| | - R. J. Kohal
- grid.7708.80000 0000 9428 7911Department of Prosthetic Dentistry, University Medical Centre Freiburg, Hugstetter Straße 55, 79106 Freiburg, Germany
| | - S. Röhling
- Private Praxis for Oral Surgery, Oralchirurgie T1, im Schäfflerhaus Theaterstr. 1, 80333 Munich, Germany
| | - B. C. Spies
- grid.7708.80000 0000 9428 7911Department of Prosthetic Dentistry, University Medical Centre Freiburg, Hugstetter Straße 55, 79106 Freiburg, Germany
| | - M. Stimmelmayr
- Private Practice for Oral Surgery, Josef-Heilingbrunner-Straße 2, 93413 Cham, Germany
| | - K. A. Grötz
- grid.491861.3Helios Dr. Horst Schmidt Kliniken Wiesbaden, Ludwig-Erhard-Straße 100, 65199 Wiesbaden, Germany
| |
Collapse
|
10
|
Influence of the Surface Chemical Composition Differences between Zirconia and Titanium with the Similar Surface Structure and Roughness on Bone Formation. NANOMATERIALS 2022; 12:nano12142478. [PMID: 35889704 PMCID: PMC9324478 DOI: 10.3390/nano12142478] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 05/24/2022] [Revised: 07/05/2022] [Accepted: 07/13/2022] [Indexed: 02/04/2023]
Abstract
The osseointegration of zirconia (ZrO2) implants is still controversial. In this study, we aimed to make clear the influence of surface chemical composition, Ti or ZrO2, to osseointegration. First, a roughened Ti surface was prepared with a combination of large-grit sandblasting and acid treatment. Then, we applied molecular precursor solution containing Zr complex onto roughened Ti surface and can deposit thin ZrO2 film onto roughened Ti surface. We can change surface chemical composition from Ti to ZrO2 without changing the surface structure and roughness of roughened Ti. The tetragonal Zr was uniformly present on the ZrO2-coated Ti surface, and the surface of the ZrO2-coated Ti showed a higher apparent zeta potential than Ti. Ti and ZrO2-coated Ti rectangular plate implant was placed into the femur bone defect. After 2 and 4 weeks of implantation, histomorphometric observation revealed that the bone-to-implant contact ratio and the bone mass values for ZrO2-coated Ti implants inserted into the femur bone defects of the rats at 2 weeks were significantly higher than those for Ti implants (p < 0.05). It revealed that ZrO2 with a similar surface structure and roughness as that of roughened Ti promoted osteogenesis equivalent to or better than that of Ti in the early bone formation stage.
Collapse
|
11
|
Li Q, Li C, Wang Y. Effect of femtosecond laser ablate ultra-fine microgrooves on surface properties of dental zirconia materials. J Mech Behav Biomed Mater 2022; 134:105361. [DOI: 10.1016/j.jmbbm.2022.105361] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/08/2022] [Revised: 07/05/2022] [Accepted: 07/09/2022] [Indexed: 10/17/2022]
|
12
|
Chopra D, Jayasree A, Guo T, Gulati K, Ivanovski S. Advancing dental implants: Bioactive and therapeutic modifications of zirconia. Bioact Mater 2022; 13:161-178. [PMID: 35224299 PMCID: PMC8843948 DOI: 10.1016/j.bioactmat.2021.10.010] [Citation(s) in RCA: 28] [Impact Index Per Article: 9.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/23/2021] [Revised: 08/22/2021] [Accepted: 10/06/2021] [Indexed: 12/16/2022] Open
Abstract
Zirconium-based implants have gained popularity in the dental implant field owing to their corrosion resistance and biocompatibility, attributed to the formation of a native zirconia (ZrO2) film. However, enhanced bioactivity and local therapy from such implants are desirable to enable the earlier establishment and improved long-term maintenance of implant integration, especially in compromised patient conditions. As a result, surface modification of zirconium-based implants have been performed using various physical, chemical and biological techniques at the macro-, micro-, and nano-scales. In this extensive review, we discuss and detail the development of Zr implants covering the spectrum from past and present advancements to future perspectives, arriving at the next generation of highly bioactive and therapeutic nano-engineered Zr-based implants. The review provides in-depth knowledge of the bioactive/therapeutic value of surface modification of Zr implants in dental implant applications focusing on clinical translation.
Collapse
Affiliation(s)
| | | | | | - Karan Gulati
- Corresponding authors. School of Dentistry, University of Queensland, 288 Herston Road, Herston QLD, 4006, Australia.
| | - Sašo Ivanovski
- Corresponding authors. School of Dentistry, University of Queensland, 288 Herston Road, Herston QLD, 4006, Australia.
| |
Collapse
|
13
|
Cruz MB, Silva N, Marques JF, Mata A, Silva FS, Caramês J. Biomimetic Implant Surfaces and Their Role in Biological Integration-A Concise Review. Biomimetics (Basel) 2022; 7:74. [PMID: 35735590 PMCID: PMC9220941 DOI: 10.3390/biomimetics7020074] [Citation(s) in RCA: 14] [Impact Index Per Article: 4.7] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/14/2022] [Revised: 05/25/2022] [Accepted: 05/27/2022] [Indexed: 12/20/2022] Open
Abstract
BACKGROUND The increased use of dental implants in oral rehabilitation has been followed by the development of new biomaterials as well as improvements in the performance of biomaterials already in use. This triggers the need for appropriate analytical approaches to assess the biological and, ultimately, clinical benefits of these approaches. AIMS To address the role of physical, chemical, mechanical, and biological characteristics in order to determine the critical parameters to improve biological responses and the long-term effectiveness of dental implant surfaces. DATA SOURCES AND METHODS Web of Science, MEDLINE and Lilacs databases were searched for the last 30 years in English, Spanish and Portuguese idioms. RESULTS Chemical composition, wettability, roughness, and topography of dental implant surfaces have all been linked to biological regulation in cell interactions, osseointegration, bone tissue and peri-implant mucosa preservation. CONCLUSION Techniques involving subtractive and additive methods, especially those involving laser treatment or embedding of bioactive nanoparticles, have demonstrated promising results. However, the literature is heterogeneous regarding study design and methodology, which limits comparisons between studies and the definition of the critical determinants of optimal cell response.
Collapse
Affiliation(s)
- Mariana Brito Cruz
- Universidade de Lisboa, Faculdade de Medicina Dentária, Unidade de Investigação em Ciências Orais e Biomédicas (UICOB), Rua Professora Teresa Ambrósio, 1600-277 Lisboa, Portugal; (J.F.M.); (A.M.)
| | - Neusa Silva
- Universidade de Lisboa, Faculdade de Medicina Dentária, Unidade de Investigação em Ciências Orais e Biomédicas (UICOB), LIBPhys-FTC UID/FIS/04559/2013, Rua Professora Teresa Ambrósio, 1600-277 Lisboa, Portugal;
| | - Joana Faria Marques
- Universidade de Lisboa, Faculdade de Medicina Dentária, Unidade de Investigação em Ciências Orais e Biomédicas (UICOB), Rua Professora Teresa Ambrósio, 1600-277 Lisboa, Portugal; (J.F.M.); (A.M.)
| | - António Mata
- Universidade de Lisboa, Faculdade de Medicina Dentária, Unidade de Investigação em Ciências Orais e Biomédicas (UICOB), Rua Professora Teresa Ambrósio, 1600-277 Lisboa, Portugal; (J.F.M.); (A.M.)
- Cochrane Portugal, Instituto de Saúde Baseada na Evidência (ISBE), Faculdade de Medicina Dentária, Universidade de Lisboa, Avenida Professor Egas Moniz, 1649-028 Lisboa, Portugal
| | - Felipe Samuel Silva
- Center for Microelectromechanical Systems (CMEMS), Department of Mechanical Engineering, University of Minho, 4800-058 Guimarães, Portugal;
| | - João Caramês
- Bone Physiology Research Group, Faculdade de Medicina Dentária, Universidade de Lisboa, Rua Professora Teresa Ambrósio, 1600-277 Lisboa, Portugal;
| |
Collapse
|
14
|
Surface Structure of Zirconia Implants: An Integrative Review Comparing Clinical Results with Preclinical and In Vitro Data. MATERIALS 2022; 15:ma15103664. [PMID: 35629692 PMCID: PMC9143528 DOI: 10.3390/ma15103664] [Citation(s) in RCA: 9] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 04/08/2022] [Revised: 05/13/2022] [Accepted: 05/19/2022] [Indexed: 01/27/2023]
Abstract
Background: The purpose of this review was to analyze and correlate the findings for zirconia implants in clinical, preclinical and in vitro cell studies in relation to surface structure. Methods: Electronic searches were conducted to identify clinical, preclinical and in vitro cell studies on zirconia implant surfaces. The primary outcomes were mean bone loss (MBL) for clinical studies, bone-to-implant contact (BIC) and removal torque (RT) for preclinical studies and cell spreading, cell proliferation and gene expression for cell studies. The secondary outcomes included comparisons of data found for those surfaces that were investigated in all three study types. Results: From 986 screened titles, 40 studies were included for data extraction. In clinical studies, only micro-structured surfaces were investigated. The lowest MBL was reported for sandblasted and subsequently etched surfaces, followed by a sinter and slurry treatment and sandblasted surfaces. For BIC, no clear preference of one surface structure was observable, while RT was slightly higher for micro-structured than smooth surfaces. All cell studies showed that cell spreading and cytoskeletal formation were enhanced on smooth compared with micro-structured surfaces. Conclusions: No correlation was observed for the effect of surface structure of zirconia implants within the results of clinical, preclinical and in vitro cell studies, underlining the need for standardized procedures for human, animal and in vitro studies.
Collapse
|
15
|
Al-Mortadi N, Bataineh K, Albakri I. A Three – Dimensional Finite Element Analysis of Polyetheretherketone PEEK in Dental Implant Prosthesis: A Novel Implant System. Open Dent J 2022. [DOI: 10.2174/18742106-v16-e2203040] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/22/2022] Open
Abstract
Purpose:
This current numerical investigation aim to evaluate the benefits of substituting Titanium with CRF- PEEK for better stress distribution in implant- bone interface.
Methods:
3D models of a dental implant for the first mandibular molar were constructed using the computed tomography (CT) scan. Four distinct models using a combination of titanium, carbon reinforced polyetheretherketone (CRF- PEEK), and zirconia for implant /abutment materials were studied. A three- dimensional finite element simulation was used to evaluate the stress distribution at the implant – bone interface under a compressive axial load of magnitude 120 N. A spherical indenter was used to simulate occlusal load.
Results:
Mesh independent study was converged for a very large number of elements. Finite element analysis showed: 1) there was no significant difference in the distribution pattern of stress at the implant – bone interface in the different material models studied, 2) the stress values for all prosthetic implant parts were well below the yield strength, 3) a larger deformation of PEEK implant versus titanium.
Conclusion:
The substitution of titanium with PEEK for the implant does not provide any better stress distribution and may lead to problems from the deformation of the implant.
Collapse
|
16
|
Musskopf ML, Finger Stadler A, Wikesjö UME, Susin C. The minipig intraoral dental implant model: A systematic review and meta-analysis. PLoS One 2022; 17:e0264475. [PMID: 35226690 PMCID: PMC8884544 DOI: 10.1371/journal.pone.0264475] [Citation(s) in RCA: 14] [Impact Index Per Article: 4.7] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/22/2021] [Accepted: 02/10/2022] [Indexed: 12/09/2022] Open
Abstract
OBJECTIVES The objective of this report was to provide a review of the minipig intraoral dental implant model including a meta-analysis to estimate osseointegration and crestal bone remodeling. METHODS A systematic review including PubMed and EMBASE databases through June 2021 was conducted. Two independent examiners screened titles/abstracts and selected full-text articles. Studies evaluating titanium dental implant osseointegration in native alveolar bone were included. A quality assessment of reporting was performed. Random-effects meta-analyses and meta-regressions were produced for bone-implant contact (BIC), first BIC, and crestal bone level. RESULTS 125 out of 249 full-text articles were reviewed, 55 original studies were included. Quality of reporting was generally low, omissions included animal characteristics, examiner masking/calibration, and sample size calculation. The typical minipig model protocol included surgical extraction of the mandibular premolars and first molar, 12±4 wks post-extraction healing, placement of three narrow regular length dental implants per jaw quadrant, submerged implant healing and 8 wks of osseointegration. Approximately 90% of studies reported undecalcified incandescent light microscopy histometrics. Overall, mean BIC was 59.88% (95%CI: 57.43-62.33). BIC increased significantly over time (p<0.001): 40.93 (95%CI: 34.95-46.90) at 2 wks, 58.37% (95%CI: 54.38-62.36) at 4 wks, and 66.33% (95%CI: 63.45-69.21) beyond 4 wks. Variability among studies was mainly explained by differences in observation interval post-extraction and post-implant placement, and implant surface. Heterogeneity was high for all studies (I2 > 90%, p<0.001). CONCLUSIONS The minipig intraoral dental implant model appears to effectively demonstrate osseointegration and alveolar bone remodeling similar to that observed in humans and canine models.
Collapse
Affiliation(s)
- Marta Liliana Musskopf
- Division of Comprehensive Oral Health–Periodontology, Laboratory for Applied Periodontal & Craniofacial Research, Adams School of Dentistry, University of North Carolina at Chapel Hill, Chapel Hill, NC, United States of America
| | - Amanda Finger Stadler
- Division of Comprehensive Oral Health–Periodontology, Laboratory for Applied Periodontal & Craniofacial Research, Adams School of Dentistry, University of North Carolina at Chapel Hill, Chapel Hill, NC, United States of America
| | - Ulf ME Wikesjö
- Division of Comprehensive Oral Health–Periodontology, Laboratory for Applied Periodontal & Craniofacial Research, Adams School of Dentistry, University of North Carolina at Chapel Hill, Chapel Hill, NC, United States of America
| | - Cristiano Susin
- Division of Comprehensive Oral Health–Periodontology, Laboratory for Applied Periodontal & Craniofacial Research, Adams School of Dentistry, University of North Carolina at Chapel Hill, Chapel Hill, NC, United States of America
| |
Collapse
|
17
|
Recent developments of biomaterial scaffolds and regenerative approaches for craniomaxillofacial bone tissue engineering. JOURNAL OF POLYMER RESEARCH 2022. [DOI: 10.1007/s10965-022-02928-4] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 12/16/2022]
|
18
|
Cunha W, Carvalho O, Henriques B, Silva FS, Özcan M, Souza JCM. Surface modification of zirconia dental implants by laser texturing. Lasers Med Sci 2022; 37:77-93. [PMID: 35022871 DOI: 10.1007/s10103-021-03475-y] [Citation(s) in RCA: 11] [Impact Index Per Article: 3.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/20/2021] [Accepted: 11/16/2021] [Indexed: 12/19/2022]
Abstract
The aim of this work was to perform an integrative literature review on the influence of laser irradiation on zirconia implants to enhance surface topographic aspects and the biological response for osseointegration. An electronic search was carried out on the PubMed database using the following search terms: "zirconia" AND "laser" AND "surface modification" OR "surface treatment" AND "dental implants" OR "bone" OR "osteoblast" OR "osseointegration." Of the identified articles, 12 studies were selected in this review. Results reported that the laser irradiation was capable of promoting changes on the zirconia surfaces regarding topographic aspects, roughness, and wettability. An increase in roughness was recorded at micro- and nano-scale and it resulted in an enhanced wettability and biological response. Also, adhesion, spreading, proliferation, and differentiation of osteogenic cells were also enhanced after laser irradiation mainly by using a femtosecond laser at 10nJ and 80 MHz. After 3 months of osseointegration, in vivo studies in dogs revealed a similar average percentage of bone-to-implant contact (BIC) on zirconia surfaces (around 47.9 ± 16%) when compared to standard titanium surfaces (61.73 ±16.27%), denoting that there is no significant difference between such different materials. The laser approach revealed several parameters that can be used for zirconia surface modification such as irradiation intensity, time, and frequency. Laser irradiation parameters can be optimized and well-controlled to reach desirable surface morphologic aspects and biological response concerning the osseointegration process.
Collapse
Affiliation(s)
- Welson Cunha
- School of Dentistry, University Institute of Health Sciences (IUCS), CESPU, 4585-116, Gandra PRD, Portugal
| | - Oscar Carvalho
- Center for MicroElectroMechanical Systems (CMEMS-UMINHO), University of Minho, Campus Azurém, 4800-058, Guimarães, Portugal
| | - Bruno Henriques
- Center for MicroElectroMechanical Systems (CMEMS-UMINHO), University of Minho, Campus Azurém, 4800-058, Guimarães, Portugal.,Ceramic and Composite Materials Research Group (CERMAT), Dept. of Mechanical Engineering (EMC), Federal University of Santa Catarina (UFSC), Florianópolis, 88040-900, Brazil
| | - Filipe S Silva
- Center for MicroElectroMechanical Systems (CMEMS-UMINHO), University of Minho, Campus Azurém, 4800-058, Guimarães, Portugal
| | - Mutlu Özcan
- Division of Dental Biomaterials, Clinic for Reconstructive Dentistry, Center of Dental Medicine, University of Zürich, Zürich, 8032, Switzerland
| | - Júlio C M Souza
- School of Dentistry, University Institute of Health Sciences (IUCS), CESPU, 4585-116, Gandra PRD, Portugal. .,Center for MicroElectroMechanical Systems (CMEMS-UMINHO), University of Minho, Campus Azurém, 4800-058, Guimarães, Portugal.
| |
Collapse
|
19
|
Borgonovo AE, Ferrario S, Maiorana C, Vavassori V, Censi R, Re D. A Clinical and Radiographic Evaluation of Zirconia Dental Implants: 10-Year Follow-Up. Int J Dent 2021; 2021:7534607. [PMID: 35003263 PMCID: PMC8739170 DOI: 10.1155/2021/7534607] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/16/2021] [Accepted: 12/17/2021] [Indexed: 12/02/2022] Open
Abstract
PURPOSE The aim is to evaluate the survival and success rates, as well as the marginal bone loss (MBL) and periodontal indexes, of zirconia implants with 10-year follow-up. MATERIALS AND METHODS 10 patients were selected and 26 one-piece zirconia implants were used for the rehabilitation of single tooth or partially edentulous ridge. After 10 years, a clinical-radiographic evaluation was performed in order to estimate peri-implant tissue health and marginal bone loss. RESULTS The survival and success rates were 100%. The average marginal bone loss from baseline to 120 months after surgery was 0.92 ± 0.97 mm. CONCLUSION One-piece zirconia dental implants are characterised by high biocompatibility, low plaque adhesion, and absence of microgap that can be related to the clinical success of these implants.
Collapse
Affiliation(s)
- Andrea Enrico Borgonovo
- Department of Esthetic Dentistry, Istituto Stomatologico Italiano, University of Milan, Milan, Italy
| | - Susanna Ferrario
- Fondazione IRCCS Ca' Granda Ospedale Maggiore Policlinico, Implant Center for Edentulism and Jawbone Atrophies, Maxillofacial Surgery and Odontostomatology Unit, University of Milan, Via Della Commenda 10, Milan 20122, Italy
| | - Carlo Maiorana
- Head Department of Implant Center for Edentulism and Jawbone Atrophies, Maxillofacial Surgery and Odontostomatology Unit, Fondazione IRCCS Ca' Granda Ospedale Maggiore Policlinico, University of Milan, Via Della Commenda 10, Milan 20122, Italy
| | - Virna Vavassori
- Department of Esthetic Dentistry, Istituto Stomatologico Italiano, University of Milan, Milan, Italy
| | - Rachele Censi
- Department of Esthetic Dentistry, Istituto Stomatologico Italiano, University of Milan, Milan, Italy
| | - Dino Re
- Head Department of Esthetic Dentistry, Istituto Stomatologico Italiano, Milan 20122, Italy
| |
Collapse
|
20
|
Jaikumar RA, Karthigeyan S, Ramesh Bhat TR, Naidu M, Praveen Raj GR, Natarajan S. Analysis of Surface Roughness and Three-dimensional Scanning Topography of Zirconia Implants before and after Photofunctionalization by Atomic Force Microscopy: An In Vitro Study. JOURNAL OF PHARMACY AND BIOALLIED SCIENCES 2021; 13:S766-S771. [PMID: 34447198 PMCID: PMC8375956 DOI: 10.4103/jpbs.jpbs_724_20] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/02/2020] [Accepted: 11/25/2020] [Indexed: 11/26/2022] Open
Abstract
Aim: To analyze surface roughness and three-dimensional (3D) scanning topography parameters of zirconia implants before and after photofunctionalization by atomic force microscopy (AFM). Materials and Methods: Ten commercially available zirconia implants five each in the study and control group were taken. The study group was subjected to ultraviolet (UV) radiation for 48 h using the shorter wavelength of 254 nm. After washing all the implants with 70% alcohol and drying, 3D surface topography and roughness parameters were analyzed using CSC 17 probe AFM at three different magnifications 25 μm, 50 μm, and 80 μm, respectively. Results: The surface topography and calculated mean amplitude, spatial, and hybrid parameters of the study group were higher than the control group (P < 0.05) in all three magnifications. Up to scale depth and peak value for the study and control group were (−0.4–0.4: −2-1) (−0.75 to 0.6:−1–1.3) (−0.75-−0.5: −1.5-1.3) for the study and control group at 25, 50, and 80 μm magnification, respectively. This indicates that photofunctionalization increased surface roughness of Zirconia implants to desirable extent. Conclusion: There is a definite difference in the quantitative topographic characteristics with zirconia implants being microroughned after photofunctionalization (UV treatment).
Collapse
Affiliation(s)
- R Arun Jaikumar
- Department of Prosthodontics, Best Dental Science College, Madurai, Tamil Nadu, India
| | - Suma Karthigeyan
- Department of Prosthodontics, Rajah Mutiah Dental College, Chidambaram, Tamil Nadu, India
| | - T R Ramesh Bhat
- Department of Prosthodontics, Best Dental Science College, Madurai, Tamil Nadu, India
| | - Madhulika Naidu
- Department of Oral Medicine and Radiology, Best Dental Science College, Madurai, Tamil Nadu, India
| | - G R Praveen Raj
- Department of Prosthodontics, Vinayaka Mission Sankarachariya Dental College, Salem, Tamil Nadu, India
| | - Senthil Natarajan
- Department of Conservative Dentistry and Endodontics, Tagore Dental College, Rathinamangalam, Tamil Nadu, India
| |
Collapse
|
21
|
Wheelis SE, Biguetti CC, Natarajan S, Arteaga A, Allami JE, Chandrashekar BL, Garlet G, Rodrigues DC. Cellular and Molecular Dynamics during Early Oral Osseointegration: A Comprehensive Characterization in the Lewis Rat. ACS Biomater Sci Eng 2021; 7:2392-2407. [PMID: 33625829 PMCID: PMC8796703 DOI: 10.1021/acsbiomaterials.0c01420] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/29/2022]
Abstract
OBJECTIVE There is a need to improve the predictability of osseointegration in implant dentistry. Current literature uses a variety of in vivo titanium (Ti) implantation models to investigate failure modes and test new materials and surfaces. However, these models produce a variety of results, making comparison across studies difficult. The purpose of this study is to validate an oral osseointegration in the Lewis rat to provide a reproducible baseline to track the inflammatory response and healing of Ti implants. METHODS Ti screws (0.76 mm Ø × 2 mm length) were implanted into the maxillary diastema of 52 adult male Lewis rats. Peri-implant tissues were evaluated 2, 7, 14, and 30 days after implantation (n = 13). Seven of the 13 samples underwent microtomographic analysis, histology, histomorphometry, and immunohistochemistry to track healing parameters. The remaining six samples underwent quantitative polymerase chain reaction (qPCR) to evaluate gene expression of inflammation and bone remodeling markers over time. RESULTS This model achieved a 78.5% success rate. Successful implants had a bone to implant contact (BIC)% of 68.86 ± 3.15 at 30 days on average. Histologically, healing was similar to other rodent models: hematoma and acute inflammation at 2 days, initial bone formation at 7, advanced bone formation and remodeling at 14, and bone maturation at 30. qPCR indicated the highest expression of bone remodeling and inflammatory markers 2-7 days, before slowly declining to nonsurgery control levels at 14-30 days. CONCLUSION This model combines cost-effectiveness and simplicity of a rodent model, while maximizing BIC, making it an excellent candidate for evaluation of new surfaces.
Collapse
Affiliation(s)
| | | | - Shruti Natarajan
- Department of Biological Sciences, University of Texas at Dallas
- Texas A&M College of Dentistry
| | | | | | | | - Gustavo Garlet
- Bauru School of Dentistry, Department of Biological Sciences, University of São Paulo São Paulo, Brazil
| | | |
Collapse
|
22
|
Kunrath MF, Gupta S, Lorusso F, Scarano A, Noumbissi S. Oral Tissue Interactions and Cellular Response to Zirconia Implant-Prosthetic Components: A Critical Review. MATERIALS 2021; 14:ma14112825. [PMID: 34070589 PMCID: PMC8198172 DOI: 10.3390/ma14112825] [Citation(s) in RCA: 16] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 03/24/2021] [Revised: 05/15/2021] [Accepted: 05/18/2021] [Indexed: 12/20/2022]
Abstract
Background: Dental components manufactured with zirconia (ZrO2) represent a significant percentage of the implant prosthetic market in dentistry. However, during the last few years, we have observed robust clinical and pre-clinical scientific investigations on zirconia both as a prosthetic and an implantable material. At the same time, we have witnessed consistent technical and manufacturing updates with regards to the applications of zirconia which appear to gradually clarify points which until recently were not well understood. Methods: This critical review evaluated the “state of the art” in relation to applications of this biomaterial in dental components and its interactions with oral tissues. Results: The physico-chemical and structural properties as well as the current surface treatment methodologies for ZrO2 were explored. A critical investigation of the cellular response to this biomaterial was completed and the clinical implications discussed. Finally, surface treatments of ZrO2 demonstrate that excellent osseointegration is possible and provide encouraging prospects for rapid bone adhesion. Furthermore, sophisticated surface treatment techniques and technologies are providing impressive oral soft tissue cell responses thus leading to superior biological seal. Conclusions: Dental devices manufactured from ZrO2 are structurally and chemically stable with biocompatibility levels allowing for safe and long-term function in the oral environment.
Collapse
Affiliation(s)
- Marcel F. Kunrath
- Dentistry Department, School of Health and Life Sciences, Pontifical Catholic University of Rio Grande do Sul (PUCRS), P.O. Box 6681, Porto Alegre 90619-900, RS, Brazil;
- Materials and Nanoscience Laboratory, Pontifical Catholic University of Rio Grande do Sul (PUCRS), P.O. Box 6681, Porto Alegre 90619-900, RS, Brazil
| | - Saurabh Gupta
- Zirconia Implant Research Group (Z.I.R.G), International Academy of Ceramic Implantology, Silver Spring, MD 20901, USA; (S.G.); (S.N.)
- Master Dental Science, Universitat Jaume I, 12071 Castellón de la Plana, Spain
| | - Felice Lorusso
- Department of Innovative Technologies in Medicine & Dentistry, University of Chieti-Pescara, Via dei Vestini, 31-66100 Chieti, CH, Italy;
| | - Antonio Scarano
- Zirconia Implant Research Group (Z.I.R.G), International Academy of Ceramic Implantology, Silver Spring, MD 20901, USA; (S.G.); (S.N.)
- Department of Innovative Technologies in Medicine & Dentistry, University of Chieti-Pescara, Via dei Vestini, 31-66100 Chieti, CH, Italy;
- Correspondence: ; Tel.: +08713554084
| | - Sammy Noumbissi
- Zirconia Implant Research Group (Z.I.R.G), International Academy of Ceramic Implantology, Silver Spring, MD 20901, USA; (S.G.); (S.N.)
- Department of Innovative Technologies in Medicine & Dentistry, University of Chieti-Pescara, Via dei Vestini, 31-66100 Chieti, CH, Italy;
| |
Collapse
|
23
|
Han J, Zhang F, Van Meerbeek B, Vleugels J, Braem A, Castagne S. Laser surface texturing of zirconia-based ceramics for dental applications: A review. MATERIALS SCIENCE & ENGINEERING. C, MATERIALS FOR BIOLOGICAL APPLICATIONS 2021; 123:112034. [PMID: 33812647 DOI: 10.1016/j.msec.2021.112034] [Citation(s) in RCA: 31] [Impact Index Per Article: 7.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 01/20/2021] [Revised: 03/02/2021] [Accepted: 03/05/2021] [Indexed: 02/07/2023]
Abstract
Laser surface texturing is widely explored for modifying the surface topography of various materials and thereby tuning their optical, tribological, biological, and other surface properties. In dentistry, improved osseointegration has been observed with laser textured titanium dental implants in clinical trials. Due to several limitations of titanium materials, dental implants made of zirconia-based ceramics are now considered as one of the best alternatives. Laser surface texturing of zirconia dental implants is therefore attracting increasing attention. However, due to the brittle nature of zirconia, as well as the metastable tetragonal ZrO2 phase, laser texturing in the case of zirconia is more challenging than in the case of titanium. Understanding these challenges requires different fields of expertise, including laser engineering, materials science, and dentistry. Even though much progress was made within each field of expertise, a comprehensive analysis of all the related factors is still missing. This review paper provides thus an overview of the common challenges and current status on the use of lasers for surface texturing of zirconia-based ceramics for dental applications, including texturing of zirconia implants for improving osseointegration, texturing of zirconia abutments for reducing peri-implant inflammation, and texturing of zirconia restorations for improving restoration retention by bonding.
Collapse
Affiliation(s)
- Jide Han
- KU Leuven, Department of Mechanical Engineering and Flanders Make@KU Leuven-MaPS, Celestijnenlaan 300, 3001 Leuven, Belgium
| | - Fei Zhang
- KU Leuven, Department of Materials Engineering, Kasteelpark Arenberg 44, 3001 Leuven, Belgium; KU Leuven, Department of Oral Health Sciences, BIOMAT, Kapucijnenvoer 7 Block A, 3000 Leuven, Belgium
| | - Bart Van Meerbeek
- KU Leuven, Department of Oral Health Sciences, BIOMAT, Kapucijnenvoer 7 Block A, 3000 Leuven, Belgium
| | - Jozef Vleugels
- KU Leuven, Department of Materials Engineering, Kasteelpark Arenberg 44, 3001 Leuven, Belgium
| | - Annabel Braem
- KU Leuven, Department of Materials Engineering, Kasteelpark Arenberg 44, 3001 Leuven, Belgium
| | - Sylvie Castagne
- KU Leuven, Department of Mechanical Engineering and Flanders Make@KU Leuven-MaPS, Celestijnenlaan 300, 3001 Leuven, Belgium.
| |
Collapse
|
24
|
Tur D, Giannis K, Unger E, Mittlböck M, Rausch-Fan X, Strbac GD. Thermal effects of various drill materials during implant site preparation-Ceramic vs. stainless steel drills: A comparative in vitro study in a standardised bovine bone model. Clin Oral Implants Res 2020; 32:154-166. [PMID: 33220104 PMCID: PMC7898889 DOI: 10.1111/clr.13685] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/18/2020] [Revised: 09/19/2020] [Accepted: 10/20/2020] [Indexed: 12/13/2022]
Abstract
OBJECTIVES The aim of this study was to evaluate thermal effects of ceramic and metal implant drills during implant site preparation using a standardised bovine model. MATERIAL AND METHODS A total of 320 automated intermittent osteotomies of 10- and 16-mm drilling depths were performed using zirconium dioxide-based and stainless steel drills. Various drill diameters (2.0/ 2.2, 2.8, 3.5, 4.2 mm ∅) and different cooling methods (without/ with external saline irrigation) were investigated at room temperature (21 ± 1°C). Temperature changes were recorded in real time using two custom-built multichannel thermoprobes in 1- and 2-mm distance to the osteotomy site. For comparisons, a linear mixed model was estimated. RESULTS Comparing thermal effects, significantly lower temperatures could be detected with steel-based drills in various drill diameters, regardless of drilling depth or irrigation method. Recorded temperatures for metal drills of all diameters and drilling depths using external irrigation were below the defined critical temperature threshold of 47°C, whereas ceramic drills of smaller diameters reached or exceeded the harmful temperature threshold at 16-mm drilling depths, regardless of whether irrigation was applied or not. The results of this study suggest that the highest temperature changes were not found at the deepest point of the osteotomy site but were observed at subcortical and deeper layers of bone, depending on drill material, drill diameter, drilling depth and irrigation method. CONCLUSIONS This standardised investigation revealed drill material and geometry to have a substantial impact on heat generation, as well as external irrigation, drilling depth and drill diameter.
Collapse
Affiliation(s)
- Dino Tur
- Clinical Division of Conservative Dentistry and Periodontology, University Clinic of Dentistry, Medical University of Vienna, Vienna, Austria
| | - Katharina Giannis
- Clinical Division Unit-Dentistry Training, University Clinic of Dentistry, Medical University of Vienna, Vienna, Austria
| | - Ewald Unger
- Center for Medical Physics and Biomedical Engineering, Medical University of Vienna, AKH Vienna, Vienna, Austria
| | - Martina Mittlböck
- Section for Clinical Biometrics, Center for Medical Statistics, Informatics and Intelligent Systems, Medical University of Vienna, Vienna, Austria
| | - Xiaohui Rausch-Fan
- Clinical Division of Conservative Dentistry and Periodontology, University Clinic of Dentistry, Medical University of Vienna, Vienna, Austria
| | - Georg D Strbac
- Clinical Division of Oral Surgery, University Clinic of Dentistry, Medical University of Vienna, Vienna, Austria
| |
Collapse
|
25
|
Laser-assisted production of HAp-coated zirconia structured surfaces for biomedical applications. J Mech Behav Biomed Mater 2020; 112:104049. [DOI: 10.1016/j.jmbbm.2020.104049] [Citation(s) in RCA: 10] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/07/2020] [Revised: 08/15/2020] [Accepted: 08/19/2020] [Indexed: 12/18/2022]
|
26
|
Takao S, Komasa S, Agariguchi A, Kusumoto T, Pezzotti G, Okazaki J. Effects of Plasma Treatment on the Bioactivity of Alkali-Treated Ceria-Stabilised Zirconia/Alumina Nanocomposite (NANOZR). Int J Mol Sci 2020; 21:E7476. [PMID: 33050494 PMCID: PMC7589822 DOI: 10.3390/ijms21207476] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/15/2020] [Revised: 09/27/2020] [Accepted: 10/06/2020] [Indexed: 11/16/2022] Open
Abstract
Zirconia ceramics such as ceria-stabilized zirconia/alumina nanocomposites (nano-ZR) are applied as implant materials due to their excellent mechanical properties. However, surface treatment is required to obtain sufficient biocompatibility. In the present study, we explored the material surface functionalization and assessed the initial adhesion of rat bone marrow mesenchymal stem cells, their osteogenic differentiation, and production of hard tissue, on plasma-treated alkali-modified nano-ZR. Superhydrophilicity was observed on the plasma-treated surface of alkali-treated nano-ZR along with hydroxide formation and reduced surface carbon. A decreased contact angle was also observed as nano-ZR attained an appropriate wettability index. Treated samples showed higher in vitro bovine serum albumin (BSA) adsorption, initial adhesion of bone marrow and endothelial vascular cells, high alkaline phosphatase activity, and increased expression of bone differentiation-related factors. Furthermore, the in vivo performance of treated nano-ZR was evaluated by implantation in the femur of male Sprague-Dawley rats. The results showed that the amount of bone formed after the plasma treatment of alkali-modified nano-ZR was higher than that of untreated nano-ZR. Thus, induction of superhydrophilicity in nano-ZR via atmospheric pressure plasma treatment affects bone marrow and vascular cell adhesion and promotes bone formation without altering other surface properties.
Collapse
Affiliation(s)
- Seiji Takao
- Department of Removable Prosthodontics and Occlusion, Osaka Dental University, 8-1 Kuzuha-hanazono-cho, Hirakata, Osaka 573-1121, Japan; (S.T.); (A.A.); (J.O.)
| | - Satoshi Komasa
- Department of Removable Prosthodontics and Occlusion, Osaka Dental University, 8-1 Kuzuha-hanazono-cho, Hirakata, Osaka 573-1121, Japan; (S.T.); (A.A.); (J.O.)
| | - Akinori Agariguchi
- Department of Removable Prosthodontics and Occlusion, Osaka Dental University, 8-1 Kuzuha-hanazono-cho, Hirakata, Osaka 573-1121, Japan; (S.T.); (A.A.); (J.O.)
| | - Tetsuji Kusumoto
- Department of Japan Faculty of Health Sciences, Osaka Dental University, 1-4-4, Makino-honmachi, Hirakata-shi, Osaka 573-1121, Japan;
| | - Giuseppe Pezzotti
- Ceramic Physics Laboratory and Research Institute for Nanoscience, Kyoto Institute of Technology, Sakyo-ku, Matsugasaki, Kyoto 606-8585, Japan;
| | - Joji Okazaki
- Department of Removable Prosthodontics and Occlusion, Osaka Dental University, 8-1 Kuzuha-hanazono-cho, Hirakata, Osaka 573-1121, Japan; (S.T.); (A.A.); (J.O.)
| |
Collapse
|
27
|
Thomé G, Sandgren R, Bernardes S, Trojan L, Warfving N, Bellón B, Pippenger BE. Osseointegration of a novel injection molded 2-piece ceramic dental implant: a study in minipigs. Clin Oral Investig 2020; 25:603-615. [PMID: 32914271 DOI: 10.1007/s00784-020-03513-z] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/28/2020] [Accepted: 08/06/2020] [Indexed: 10/23/2022]
Abstract
OBJECTIVES This study compared the osseointegrative potential of a novel injection molded zirconia dental implant (Neodent Zi ceramic implant, test) and a commercially available titanium implant (Neodent Alvim implant, control) in terms of histomorphometrically derived bone-to-implant contact (BIC), first bone-to-implant contact (fBIC), and the ratio of bone area to total area (BATA) around the implant. MATERIALS AND METHODS A total of 36 implants, 18 per individual test device, were implanted in a split-mouth arrangement in either side of the edentulous and fully healed mandible of 6 minipigs. Histomorphometric analysis of BIC, fBIC, and BATA were performed 8 weeks post implantation and subjected to statistical non-inferiority testing. Surface characteristics of both implant types were compared in terms of contact angle, surface topography, and elemental composition. RESULTS BIC, fBIC, and coronal BATA values of test and control implants were statistically comparable and non-inferior. BIC values of 77.8 ± 6.9% vs. 80.7 ± 6.9% (p = 0.095) were measured for the test and control groups. fBIC lingual values were - 238 ± 328 μm compared with - 414 ± 511 μm (p = 0.121) while buccal values were - 429 ± 648 μm and - 588 ± 550 μm (p = 0.230) for the test and control devices, respectively. BATA in the apical segment was significantly higher in the test group compared with the control group (67.2 ± 11.8% vs. 59.1 ± 11.4%) (p = 0.0103). Surface topographies of both implant types were comparable. Surface chemical analysis indicated the presence of carbonaceous adsorbates which correlated with a comparable and predominantly hydrophobic character of the implants. CONCLUSION The results demonstrate that the investigated zirconia implants, when compared with a commercially available titanium implant, show equivalent and non-inferior bone integration, bone formation, and alveolar bone level maintenance. This qualifies the investigated zirconia implant as a potential candidate for clinical development. CLINICAL RELEVANCE This study investigated the osseointegration of a novel zirconia 2-piece dental implant prototype intended for clinical development. With the aim of translating this prototype into clinical development preclinical models, procedures and materials within this study have been selected as close to clinical practice and human physiological conditions as possible.
Collapse
Affiliation(s)
| | - Rebecca Sandgren
- Biomedical Center, Faculty of Medicine, Lund University, Lund, Sweden
| | | | | | | | - Benjamin Bellón
- Department of Preclinical and Translational Research, Institut Straumann AG, Peter Merian-Weg 12, 4052, Basel, Switzerland.,Department of Periodontology, Faculty of Dentistry, University of Zurich, Zurich, Switzerland
| | - Benjamin E Pippenger
- Department of Preclinical and Translational Research, Institut Straumann AG, Peter Merian-Weg 12, 4052, Basel, Switzerland. .,Department of Periodontology, Faculty of Dentistry, University of Zurich, Zurich, Switzerland.
| |
Collapse
|
28
|
He X, Reichl FX, Milz S, Michalke B, Wu X, Sprecher CM, Yang Y, Gahlert M, Röhling S, Kniha H, Hickel R, Högg C. Titanium and zirconium release from titanium- and zirconia implants in mini pig maxillae and their toxicity in vitro. Dent Mater 2020; 36:402-412. [DOI: 10.1016/j.dental.2020.01.013] [Citation(s) in RCA: 31] [Impact Index Per Article: 6.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/07/2019] [Revised: 12/02/2019] [Accepted: 01/14/2020] [Indexed: 11/17/2022]
|
29
|
|
30
|
Affiliation(s)
- Takao HANAWA
- Institute of Biomaterials and Bioengineering, Tokyo Medical and Dental University
| |
Collapse
|
31
|
Iinuma Y, Hirota M, Hayakawa T, Ohkubo C. Surrounding Tissue Response to Surface-Treated Zirconia Implants. MATERIALS 2019; 13:ma13010030. [PMID: 31861679 PMCID: PMC6981750 DOI: 10.3390/ma13010030] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 11/22/2019] [Revised: 12/06/2019] [Accepted: 12/16/2019] [Indexed: 11/16/2022]
Abstract
Yttria-stabilized tetragonal zirconia polycrystals (Y-TZP), which are partially stabilized zirconia, have been used for fabricating dental implants. This study investigated the soft tissue attachment, the collagen fiber orientation to zirconia at different surface conditions, and the bone response using implantation experiments in animals. The zirconia implant surfaces were treated with ultraviolet irradiation (UV), a combination of large-grit sandblasting and hydrofluoric acid etching (blastedHF), and a combination of blastedHF and UV (blastedHF+UV). The surface treated with blastedHF and blastedHF+UV appeared rough and hydrophilic. The surface treated with blastedHF+UV appeared to be superhydrophilic. Subsequently, tapered cylindrical zirconia implants were placed in the alveolar sockets of the maxillary molars of rats. The bone-to-implant contact ratio of blastedHF and blastedHF+UV implants was significantly higher than that of the non-treated controls and UV-treated implants. The four different surface-treated zirconia implants demonstrated tight soft tissue attachments. Perpendicularly oriented collagen fibers towards zirconia implants were more prominent in blastedHF and blastedHF+UV implants compared to the controls and UV-treated implants. The area of the soft tissue attachment was the greatest with the perpendicularly oriented collagen fibers of blastedHF+UV-treated implants. In conclusion, blastedHF+UV treatment could be beneficial for ensuring greater soft-tissue attachment for zirconia implants.
Collapse
Affiliation(s)
- Yohei Iinuma
- Department of Removable Prosthodontics, School of Dental Medicine, Tsurumi University, 2-1-3, Tsurumi, Yokohama, Kanagawa 230-8501, Japan;
- Correspondence: ; Tel.: +81-45580-8421
| | - Masatsugu Hirota
- School of Dental Medicine, Tsurumi University, 2-1-3, Tsurumi, Yokohama, Kanagawa 230-8501, Japan; (M.H.); (T.H.)
| | - Tohru Hayakawa
- School of Dental Medicine, Tsurumi University, 2-1-3, Tsurumi, Yokohama, Kanagawa 230-8501, Japan; (M.H.); (T.H.)
| | - Chikahiro Ohkubo
- Department of Removable Prosthodontics, School of Dental Medicine, Tsurumi University, 2-1-3, Tsurumi, Yokohama, Kanagawa 230-8501, Japan;
| |
Collapse
|
32
|
Roehling S, Schlegel KA, Woelfler H, Gahlert M. Zirconia compared to titanium dental implants in preclinical studies—A systematic review and meta‐analysis. Clin Oral Implants Res 2019; 30:365-395. [DOI: 10.1111/clr.13425] [Citation(s) in RCA: 48] [Impact Index Per Article: 8.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/11/2018] [Revised: 02/27/2019] [Accepted: 03/12/2019] [Indexed: 12/22/2022]
Affiliation(s)
- Stefan Roehling
- Clinic for Oral and Cranio‐Maxillofacial Surgery Hightech Research Center University Hospital Basel University of Basel Basel Switzerland
- Clinic for Oral and Cranio‐Maxillofacial Surgery Kantonsspital Aarau Aarau Switzerland
- Unit for Oral & Maxillofacial Surgery Medical Healthcare Center Lörrach Lörrach Germany
| | - Karl A. Schlegel
- Private Clinic for Oral and Maxillofacial Surgery Prof. Schlegel Munich Germany
- Maxillofacial Surgery Department University Hospital Erlangen University of Erlangen Erlangen Germany
| | | | - Michael Gahlert
- Clinic for Oral and Cranio‐Maxillofacial Surgery Hightech Research Center University Hospital Basel University of Basel Basel Switzerland
- Dental Clinic for Oral Surgery and Implant Dentistry Prof. Gahlert Munich Germany
- Department for Oral Surgery Faculty of Medicine Sigmund Freud University Vienna Vienna Austria
| |
Collapse
|
33
|
Schünemann FH, Galárraga-Vinueza ME, Magini R, Fredel M, Silva F, Souza JCM, Zhang Y, Henriques B. Zirconia surface modifications for implant dentistry. MATERIALS SCIENCE & ENGINEERING. C, MATERIALS FOR BIOLOGICAL APPLICATIONS 2019; 98:1294-1305. [PMID: 30813009 DOI: 10.1016/j.msec.2019.01.062] [Citation(s) in RCA: 132] [Impact Index Per Article: 22.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 07/13/2018] [Revised: 01/13/2019] [Accepted: 01/14/2019] [Indexed: 02/07/2023]
Abstract
BACKGROUND Zirconia has emerged as a versatile dental material due to its excellent aesthetic outcomes such as color and opacity, unique mechanical properties that can mimic the appearance of natural teeth and decrease peri-implant inflammatory reactions. OBJECTIVE The aim of this review was to critically explore the state of art of zirconia surface treatment to enhance the biological and osseointegration behavior of zirconia in implant dentistry. MATERIALS AND METHODS An electronic search in PubMed database was carried out until May 2018 using the following combination of key words and MeSH terms without time periods: "zirconia surface treatment" or "zirconia surface modification" or "zirconia coating" and "osseointegration" or "biological properties" or "bioactivity" or "functionally graded properties". RESULTS Previous studies have reported the influence of zirconia-based implant surface on the adhesion, proliferation, and differentiation of osteoblast and fibroblasts at the implant to bone interface during the osseointegration process. A large number of physicochemical methods have been used to change the implant surfaces and therefore to improve the early and late bone-to-implant integration, namely: acid etching, gritblasting, laser treatment, UV light, CVD, and PVD. The development of coatings composed of silica, magnesium, graphene, dopamine, and bioactive molecules has been assessed although the development of a functionally graded material for implants has shown encouraging mechanical and biological behavior. CONCLUSION Modified zirconia surfaces clearly demonstrate faster osseointegration than that on untreated surfaces. However, there is no consensus regarding the surface treatment and consequent morphological aspects of the surfaces to enhance osseointegration.
Collapse
Affiliation(s)
- Fernanda H Schünemann
- School of Dentistry (DODT), Post-Graduate Program in Dentistry (PPGO), Federal University of Santa Catarina (UFSC), Campus Trindade, 88040-900 Florianópolis, SC, Brazil
| | - María E Galárraga-Vinueza
- School of Dentistry (DODT), Post-Graduate Program in Dentistry (PPGO), Federal University of Santa Catarina (UFSC), Campus Trindade, 88040-900 Florianópolis, SC, Brazil
| | - Ricardo Magini
- School of Dentistry (DODT), Post-Graduate Program in Dentistry (PPGO), Federal University of Santa Catarina (UFSC), Campus Trindade, 88040-900 Florianópolis, SC, Brazil
| | - Márcio Fredel
- Ceramic and Composite Materials Research Group (CERMAT), Federal University of Santa Catarina (UFSC), Campus Trindade, 88040-900, Florianópolis, SC, Brazil
| | - Filipe Silva
- CMEMS-UMinho, University of Minho, Campus de Azurém, 4800-058 Guimarães, Portugal
| | - Júlio C M Souza
- CMEMS-UMinho, University of Minho, Campus de Azurém, 4800-058 Guimarães, Portugal; Department of Dental Sciences, University Institute of Health Sciences (IUCS), CESPU, 4585-116, Gandra, Portugal
| | - Yu Zhang
- Department of Biomaterials and Biomimetics, New York University College of Dentistry, NYU, New York, NY 10010, USA
| | - Bruno Henriques
- Ceramic and Composite Materials Research Group (CERMAT), Federal University of Santa Catarina (UFSC), Campus Trindade, 88040-900, Florianópolis, SC, Brazil; CMEMS-UMinho, University of Minho, Campus de Azurém, 4800-058 Guimarães, Portugal.
| |
Collapse
|
34
|
Rottmar M, Müller E, Guimond-Lischer S, Stephan M, Berner S, Maniura-Weber K. Assessing the osteogenic potential of zirconia and titanium surfaces with an advanced in vitro model. Dent Mater 2019; 35:74-86. [DOI: 10.1016/j.dental.2018.10.008] [Citation(s) in RCA: 15] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/04/2018] [Revised: 09/12/2018] [Accepted: 10/12/2018] [Indexed: 10/27/2022]
|
35
|
Lopez CAV, Vasco MAA, Ruales E, Bedoya KA, Benfatti CM, Bezzon OL, Deliberador TM. Three-Dimensional Finite Element Analysis of Stress Distribution in Zirconia and Titanium Dental Implants. J ORAL IMPLANTOL 2018; 44:409-415. [DOI: 10.1563/aaid-joi-d-16-00109] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/22/2022]
Abstract
Zirconia has been presented as an alternative biomaterial to titanium, commercially presented as a single-body implant and/or as an abutment, demonstrating clinically biocompatible favorable results in white and rose esthetics. However, the number of long-term in vivo studies and mechanical tests evaluating the response of stress distribution compared with titanium implants is still limited. The aim of the study was to compare the principal peak stresses in the peri-implant bone around titanium and zirconia implants using the finite element method. Four groups of 3-dimensional models were constructed for the tests: G1, external hexagon titanium implant with a zirconia abutment; G2, zirconia implant with a zirconia abutment; G3, single-body titanium implant; and G4, single-body zirconia implant. Axial and oblique loads of 100 N at 45° were simulated in the prosthetic crown. The bone results showed that the peak stresses decreased by 12% in zirconia implants with 2 parts for axial load and 30% for the oblique load. In single-body implants, the peak stresses decreased 12% in the axial load and 34% in the oblique load when a zirconia implant was used compared with a titanium implant. Although the stress values in megapascals are similar, it can be concluded that the zirconia implants decrease the stress peaks at the peri-implant bone area around the implant platform when compared with titanium implants.
Collapse
Affiliation(s)
- Camilo Andres Villabona Lopez
- Department of Dentistry, Santo Tomás University, Bucaramanga, Santander, Colombia
- Faculty of Dentistry, SLMANDIC, Curitiba, PR, Brazil
| | - Marco Antônio Amorin Vasco
- Department of Oral Rehabilitation, University of São Paulo, Ribeirao Preto, Sao Paulo, Brazil
- Department of Bioengineering, University of Zaragoza, Zaragoza, Spain
| | - Edwin Ruales
- Center for Education and Research on Dental Implants (CEPID), Department of Implantology, Federal University of Santa Cataria, Florianópolis, Brazil
| | - Karin Apaza Bedoya
- Center for Education and Research on Dental Implants (CEPID), Department of Implantology, Federal University of Santa Cataria, Florianópolis, Brazil
| | - Cesar Magalhaes Benfatti
- Center for Education and Research on Dental Implants (CEPID), Department of Implantology, Federal University of Santa Cataria, Florianópolis, Brazil
| | - Osvaldo Luis Bezzon
- Department of Oral Rehabilitation, University of São Paulo, Ribeirao Preto, Sao Paulo, Brazil
- Department of Bioengineering, University of Zaragoza, Zaragoza, Spain
| | - Tatiana Miranda Deliberador
- Faculty of Dentistry, SLMANDIC, Curitiba, PR, Brazil
- Department of Dentistry, Positivo University, Curitiba, Paraná, Brazil
| |
Collapse
|
36
|
A prospective clinical study to evaluate the performance of zirconium dioxide dental implants in single-tooth edentulous area: 3-year follow-up. BMC Oral Health 2018; 18:181. [PMID: 30382850 PMCID: PMC6211599 DOI: 10.1186/s12903-018-0636-x] [Citation(s) in RCA: 31] [Impact Index Per Article: 4.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/21/2017] [Accepted: 10/10/2018] [Indexed: 11/10/2022] Open
Abstract
BACKGROUND Traditionally, dental implants have been made from titanium or titanium alloys. Alternatively, zirconia-based ceramic implants have been developed with similar characteristics of functional strength and osseointegration. Ceramic implants offer advantages in certain settings, e.g. in patients who object to metal dental implants. The aim of this study was to investigate the mid-term (36 months) clinical performance of a ceramic monotype implant in single-tooth edentulous area. METHODS This was a prospective, open-label, single-arm study in patients requiring implant rehabilitation in single-tooth edentulous area. Ceramic implants (PURE Ceramic Implant, Institut Straumann AG, Basel, Switzerland) with a diameter of 4.1 mm were placed following standard procedure and loaded with provisional and final prostheses after 3 and 6 months, respectively. Implant survival rate and implant success rate were evaluated and crestal bone levels were measured by analysing standardized radiographs during implant surgery and at 6, 12, 24 and 36 months. RESULTS Forty-four patients received a study implant, of whom one patient withdrew consent after 3 months. With one implant lost during the first 6 months after surgery, the implant survival rate was 97.7% at 6 months. No further implants were lost over the following 30 months, and 3 patients were lost to follow-up during this time frame. This led to a survival rate of 97.5% at 36 months. Six months after implant surgery 93.0% of the implants were considered "successful", increasing to 97.6% at 12 months and remaining at this level at 24 months (95.1%) and 36 months (97.5%). Bone loss was most pronounced in the first half-year after implant surgery (0.88 ± 0.86 mm). By contrast, between 12 and 36 months the mean bone level remained stable (minimal gain of 0.06 [± 0.60] mm). Hence, the overall bone loss from implant surgery to 36 months was 0.97 (± 0.88) mm. CONCLUSIONS In the follow-up period ceramic implants can achieve favourable clinical outcomes on a par with titanium implants. For instance, these implants can be recommended for patients who object to metal dental implants. However, longer term studies with different edentulous morphology need to confirm the present data. TRIAL REGISTRATION Registered on www.clinicaltrials.gov : NCT02163395 .
Collapse
|
37
|
Roehling S, Schlegel KA, Woelfler H, Gahlert M. Performance and outcome of zirconia dental implants in clinical studies: A meta‐analysis. Clin Oral Implants Res 2018; 29 Suppl 16:135-153. [DOI: 10.1111/clr.13352] [Citation(s) in RCA: 55] [Impact Index Per Article: 7.9] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/03/2017] [Revised: 02/28/2018] [Accepted: 07/04/2018] [Indexed: 12/14/2022]
Affiliation(s)
- Stefan Roehling
- Clinic for Oral and Cranio‐Maxillofacial SurgeryHightech Research CenterUniversity Hospital BaselUniversity of Basel Basel Switzerland
- Clinic for Oral and Cranio‐Maxillofacial SurgeryKantonsspital Aarau Aarau Switzerland
- Unit for Oral & Maxillofacial SurgeryMedical Healthcare Center Lörrach Lörrach Germany
| | - Karl A. Schlegel
- Private Clinic for Oral and Maxillofacial Surgery Prof. Schlegel Munich Germany
- Maxillofacial Surgery DepartmentUniversity Hospital ErlangenUniversity of Erlangen Erlangen Germany
| | | | - Michael Gahlert
- Clinic for Oral and Cranio‐Maxillofacial SurgeryHightech Research CenterUniversity Hospital BaselUniversity of Basel Basel Switzerland
- Private Dental Clinic PD Dr. Gahlert Munich Germany
| |
Collapse
|
38
|
Current status of zirconia implants in dentistry: preclinical tests. J Prosthodont Res 2018; 63:1-14. [PMID: 30205949 DOI: 10.1016/j.jpor.2018.07.006] [Citation(s) in RCA: 41] [Impact Index Per Article: 5.9] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/24/2017] [Revised: 07/18/2018] [Accepted: 07/26/2018] [Indexed: 11/23/2022]
Abstract
PURPOSE This systematic review aimed to provide an overview of zirconia implants as well as regarding the outcome of the implant-restorative complex in preclinical studies. STUDY SELECTION An electronic search of the literature prior to July 2017 was performed to identify all articles related to preclinical research on zirconia implants. The search was conducted using MEDLINE (National Library of Medicine) and PubMed without restrictions concerning the date of publication. The search terminology included: zirconia implant, osseointegration, bone-to-implant contact, soft tissue, histology, histomorphometry, surface modification, surface roughness, surface characteristics, and restoration (connecting multiple keywords with AND, OR). RESULTS Fifty-seven studies were finally selected from an initial yield of 654 titles, and the data were extracted. The identified preclinical studies focused on several aspects related to zirconia implants, namely biocompatibility, mechanical properties, implant design, osseointegration capacity, soft tissue response, and restorative options. Due to heterogeneity of the studies, a meta-analysis was not possible. The most frequently used zirconia material for the fabrication of implants is yttria-stabilized tetragonal zirconia polycrystal. The resistance-to-fracture for zirconia implants ranged between 516-2044N. The mostly investigated parameter was osseointegration, which is compared to that of titanium. A lack of evidence was found with other parameters. CONCLUSIONS Due to its good biocompatibility as well as favorable physical and mechanical properties, zirconia implants are a potential alternative to titanium implants. However, knowledge regarding the implant-restorative complex and related aspects is still immature to recommend its application for daily practice.
Collapse
|
39
|
Hein AT, Cho YD, Jo YH, Kim DJ, Han JS. Analysis of osteogenic potential on 3mol% yttria-stabilized tetragonal zirconia polycrystals and two different niobium oxide containing zirconia ceramics. J Adv Prosthodont 2018; 10:147-154. [PMID: 29713436 PMCID: PMC5917107 DOI: 10.4047/jap.2018.10.2.147] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/24/2017] [Revised: 09/13/2017] [Accepted: 10/30/2017] [Indexed: 12/11/2022] Open
Abstract
PURPOSE This study was performed to evaluate the osteogenic potential of 3mol% yttria-stabilized tetragonal zirconia polycrystals (3Y-TZP) and niobium oxide containing Y-TZPs with specific ratios, new (Y,Nb)-TZPs, namely YN4533 and YN4533/Al20 discs. MATERIALS AND METHODS 3Y-TZP, YN4533 and YN4533/Al20 discs (15 mm diameter and 1 mm thickness) were prepared and their average surface roughness (Ra) and surface topography were analyzed using 3-D confocal laser microscope (CLSM) and scanning electron microscope (SEM). Mouse pre-osteoblast MC3T3-E1 cells were seeded onto all zirconia discs and evaluated with regard to cell attachment and morphology by (CLSM), cell proliferation by PicoGreen assay, and cell differentiation by Reverse-Transcription PCR and Quantitative Real-Time PCR, and alkaline phosphatase (Alp) staining. RESULTS The cellular morphology of MC3T3-E1 pre-osteoblasts was more stretched on a smooth surface than on a rough surface, regardless of the material. Cellular proliferation was higher on smooth surfaces, but there were no significant differences between 3Y-TZP, YN4533, and YN4533/Al20. Osteoblast differentiation patterns on YN4533 and YN4533/Al20 were similar to or slightly higher than seen in 3Y-TZP. Although there were no significant differences in bone marker gene expression (alkaline phosphatase and osteocalcin), Alp staining indicated better osteoblast differentiation on YN4533 and YN4533/Al20 compared to 3Y-TZP. CONCLUSION Based on these results, niobium oxide containing Y-TZPs have comparable osteogenic potential to 3Y-TZP and are expected to be suitable alternative ceramics dental implant materials to titanium for aesthetically important areas.
Collapse
Affiliation(s)
- Aung Thu Hein
- Department of Prosthodontics, School of Dentistry, Seoul National University, Seoul, Republic of Korea
| | - Young-Dan Cho
- Department of Periodontology, School of Dentistry and Dental Research Institute, BK21 Program, Seoul National University, Seoul, Republic of Korea
| | - Ye-Hyeon Jo
- Department of Prosthodontics, School of Dentistry, Seoul National University, Seoul, Republic of Korea
| | - Dae-Joon Kim
- Department of Advanced Materials Engineering, Sejong University, Seoul, Republic of Korea
| | - Jung-Suk Han
- Department of Prosthodontics, School of Dentistry, Seoul National University, Seoul, Republic of Korea
| |
Collapse
|
40
|
Bosshardt DD, Chappuis V, Buser D. Osseointegration of titanium, titanium alloy and zirconia dental implants: current knowledge and open questions. Periodontol 2000 2018; 73:22-40. [PMID: 28000277 DOI: 10.1111/prd.12179] [Citation(s) in RCA: 294] [Impact Index Per Article: 42.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/15/2022]
Abstract
Bone healing around dental implants follows the pattern and sequence of intramembraneous osteogenesis with formation of woven bone first of all followed later by formation of parallel-fibered and lamellar bone. Bone apposition onto the implant surface starts earlier in trabecular bone than in compact bone. While the first new bone may be found on the implant surface around 1 week after installation, bone remodeling starts at between 6 and 12 weeks and continues throughout life. Bone remodeling also involves the bone-implant interface, thus transiently exposing portions of the implant surface. Surface modifications creating micro-rough implant surfaces accelerate the osseointegration process of titanium implants, as demonstrated in numerous animal experiments. Sandblasting followed by acid-etching may currently be regarded as the gold standard technique to create micro-rough surfaces. Chemical surface modifications, resulting in higher hydrophilicity, further increase the speed of osseointegration of titanium and titanium-zirconium implants in both animals and humans. Surface modifications of zirconia and alumina-toughened zirconia implants also have an influence on the speed of osseointegration, and some implant types reach high bone-to-implant contact values in animals. Although often discussed independently of each other, surface characteristics, such as topography and chemistry, are virtually inseparable. Contemporary, well-documented implant systems with micro-rough implant surfaces, placed by properly trained and experienced clinicians, demonstrate high long-term survival rates. Nevertheless, implant failures do occur. A low percentage of implants are diagnosed with peri-implantitis after 10 years in function. In addition, a low number of implants seem to be lost for primarily reasons other than biofilm-induced infection. Patient factors, such as medications interfering with the immune system and bone cells, may be an element contributing to continuous bone loss and should therefore be monitored and studied in greater detail.
Collapse
|
41
|
Janner SFM, Gahlert M, Bosshardt DD, Roehling S, Milz S, Higginbottom F, Buser D, Cochran DL. Bone response to functionally loaded, two-piece zirconia implants: A preclinical histometric study. Clin Oral Implants Res 2017; 29:277-289. [PMID: 29288505 DOI: 10.1111/clr.13112] [Citation(s) in RCA: 25] [Impact Index Per Article: 3.1] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Accepted: 11/16/2017] [Indexed: 12/21/2022]
Abstract
OBJECTIVE To evaluate the bone response to a two-piece zirconia implant in comparison with a control titanium implant in the canine mandible 4 and 16 weeks after restoration. MATERIAL AND METHODS Zirconia and titanium implants were alternately placed bilaterally in healed mandibular molar and premolar sites of five canines. Full-ceramic single-tooth restorations were cemented after 6 weeks of transmucosal healing, allowing for full functional loading of the implants. Histologic and histometric analyses were performed on orofacial and mesiodistal undecalcified sections of the specimens obtained upon sacrifice after 4 and 16 weeks of functional loading. Bone-to-implant contact (BIC), multinucleated giant cells-to-implant contact (MIC), crestal bone level, and peri-implant bone density were histometrically assessed. RESULTS All 60 implants and 60 restorations were still in function after 4 and 16 weeks of loading in both test and control groups. No implant loss, no implant or abutment fracture, and no chipping of the restorations could be detected. Histometric analysis showed no statistically significant differences between zirconia and titanium implants in BIC, crestal bone level, and peri-implant bone density at both time points. Between 4 and 16 weeks, the crestal bone level around zirconia implants showed a small but statistically significant increase in its distance from the implant shoulder. MIC was very low on both implant types and both time points and decreased statistically significantly overtime. CONCLUSION The present two-piece zirconia implant showed a similar bone integration compared to the titanium implant with similar surface morphology after 4 and 16 weeks of loading.
Collapse
Affiliation(s)
- Simone F M Janner
- Department of Periodontics, University of Texas Health Science Center at San Antonio, San Antonio, TX, USA.,Department of Oral Surgery and Stomatology, School of Dental Medicine, University of Bern, Bern, Switzerland
| | - Michael Gahlert
- Clinic for Oral and Cranio-Maxillofacial Surgery, Hightech Research Center, University Hospital Basel, University of Basel, Basel, Switzerland.,Private Practice, Munich, Germany
| | - Dieter D Bosshardt
- Robert K. Schenk Laboratory of Oral Histology, School of Dental Medicine, University of Bern, Bern, Switzerland
| | - Stefan Roehling
- Department of Periodontics, University of Texas Health Science Center at San Antonio, San Antonio, TX, USA.,Clinic for Oral and Cranio-Maxillofacial Surgery, Hightech Research Center, University Hospital Basel, University of Basel, Basel, Switzerland
| | - Stefan Milz
- Anatomische Anstalt, Ludwig-Maximilians University, Munich, Germany
| | | | - Daniel Buser
- Department of Oral Surgery and Stomatology, School of Dental Medicine, University of Bern, Bern, Switzerland
| | - David L Cochran
- Department of Periodontics, University of Texas Health Science Center at San Antonio, San Antonio, TX, USA
| |
Collapse
|
42
|
Pieralli S, Kohal RJ, Lopez Hernandez E, Doerken S, Spies BC. Osseointegration of zirconia dental implants in animal investigations: A systematic review and meta-analysis. Dent Mater 2017; 34:171-182. [PMID: 29122237 DOI: 10.1016/j.dental.2017.10.008] [Citation(s) in RCA: 33] [Impact Index Per Article: 4.1] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/14/2017] [Revised: 10/17/2017] [Accepted: 10/18/2017] [Indexed: 12/26/2022]
Abstract
OBJECTIVE To determine the osseointegration rate of zirconium dioxide (ZrO2) dental implants in preclinical investigations. DATA Data on the osseointegration rate was extracted considering the bone to implant contact (BIC), removal torque analysis (RTQ) and push-in tests. Meta analyses were conducted using multilevel multivariable mixed-effects linear regression models. The Šidák method was used in case of multiple testing. SOURCES An electronic screening of the literature (MEDLINE/Pubmed, Cochrane Library and Embase) and a supplementary manual search were performed. Animal investigations with a minimum sample size of 3 units evaluating implants made of zirconia (ZrO2) or its composites (ZrO2>50vol.%) were included. STUDY SELECTION The search provided 4577 articles, and finally 54 investigations were included and analyzed. Fifty-two studies included implants made from zirconia, 4 zirconia composite implants and 37 titanium implants. In total, 3435 implants were installed in 954 animals. CONCLUSIONS No significant influence of the evaluated bulk materials on the outcomes of interest could be detected. When comparing different animal models, significant differences for the evaluated variables could be found. These results might be of interest for the design of further animal investigations.
Collapse
Affiliation(s)
- Stefano Pieralli
- Medical Center - University of Freiburg, Center for Dental Medicine, Department of Prosthetic Dentistry, Faculty of Medicine - University of Freiburg, Hugstetter Str. 55, 79106 Freiburg, Germany; Charité - Universitätsmedizin Berlin, Campus Benjamin Franklin (CBF), CC 3 Dental and Craniofacial Sciences, Department of Prosthodontics, Geriatric Dentistry and Craniomandibular Disorders, Aßmannshauser Straße 4-6, 14197 Berlin, Germany.
| | - Ralf-Joachim Kohal
- Medical Center - University of Freiburg, Center for Dental Medicine, Department of Prosthetic Dentistry, Faculty of Medicine - University of Freiburg, Hugstetter Str. 55, 79106 Freiburg, Germany
| | - Emilia Lopez Hernandez
- Medical Center - University of Freiburg, Center for Dental Medicine, Department of Prosthetic Dentistry, Faculty of Medicine - University of Freiburg, Hugstetter Str. 55, 79106 Freiburg, Germany
| | - Sam Doerken
- Medical Center - University of Freiburg, Center for Medical Biometry and Medical Informatics, Institute for Medical Biometry and Statistics, Faculty of Medicine - University of Freiburg, Hebelstr. 11, 79104 Freiburg, Germany
| | - Benedikt Christopher Spies
- Medical Center - University of Freiburg, Center for Dental Medicine, Department of Prosthetic Dentistry, Faculty of Medicine - University of Freiburg, Hugstetter Str. 55, 79106 Freiburg, Germany; Charité - Universitätsmedizin Berlin, Campus Benjamin Franklin (CBF), CC 3 Dental and Craniofacial Sciences, Department of Prosthodontics, Geriatric Dentistry and Craniomandibular Disorders, Aßmannshauser Straße 4-6, 14197 Berlin, Germany
| |
Collapse
|
43
|
Martins R, Cestari TM, Arantes RVN, Santos PS, Taga R, Carbonari MJ, Oliveira RC. Osseointegration of zirconia and titanium implants in a rabbit tibiae model evaluated by microtomography, histomorphometry and fluorochrome labeling analyses. J Periodontal Res 2017; 53:210-221. [PMID: 29044523 DOI: 10.1111/jre.12508] [Citation(s) in RCA: 12] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Accepted: 09/01/2017] [Indexed: 02/02/2023]
Abstract
OBJECTIVES This study compares the osseointegration of machined-zirconia implants containing yttria (M-Y-TZP) with machined (M-Ti) and resorbable blast media (RBM-Ti) titanium implants. MATERIAL AND METHODS M-Y-TZP, M-Ti and RBM-Ti implants were randomly placed in rabbit tibiae. Fluorochrome bone labels (tetracycline, alizarin and calcein) were administered at different time periods. After 8 weeks, osseointegration was evaluated in terms of bone-to-implant contact (BIC), new bone area (nBA), remaining cortical bone area (rBA) and temporal quantification of fluorochromes, using micro-CT and histomorphometric analyses. RESULTS RBM-Ti implants showed higher resorption of the remaining cortical bone and bone formation (rBA = 36.9% and nBA = 38.8%) than M-Y-TZP implants (rBA = 48% and nBA = 26.5%). The BIC values showed no differences among the groups in the cortical region (mean = 52.2%) but in the medullary region, they were 0.45-fold higher in the RBM-Ti group (51.2%) than in the M-Y-TZP group (35.2%). In all groups, high incorporation of tetracycline was observed (2nd to 4th weeks), followed by alizarin (4th to 6th weeks) and calcein (6th to 8th weeks). In the cortical region, incorporation of tetracycline was similar between RBM-Ti (49.8%) and M-Y-TZP (35.9%) implants, but higher than M-Ti (28.2%) implants. Subsequently, alizarin and calcein were 1.1-fold higher in RBM-Ti implants than in the other implants. In the medullary region, no significant differences were observed for all fluorochromes. CONCLUSION All implants favored bone formation and consequently promoted primary stability. Bone formation around the threads was faster in RBM-Ti and M-Y-TZP implants than in M-Ti implants, but limited bone remodeling with M-Y-TZP implants over time can have significant effects on secondary stability, suggesting caution for its use as an alternative substitute for titanium implants.
Collapse
Affiliation(s)
- R Martins
- Department of Biological Sciences, Bauru School of Dentistry, University of São Paulo, Bauru, SP, Brazil
| | - T M Cestari
- Department of Biological Sciences, Bauru School of Dentistry, University of São Paulo, Bauru, SP, Brazil
| | - R V N Arantes
- Department of Biological Sciences, Bauru School of Dentistry, University of São Paulo, Bauru, SP, Brazil
| | - P S Santos
- Department of Biological Sciences, Bauru School of Dentistry, University of São Paulo, Bauru, SP, Brazil
| | - R Taga
- Department of Biological Sciences, Bauru School of Dentistry, University of São Paulo, Bauru, SP, Brazil
| | - M J Carbonari
- Insper - Instituto de Ensino e Pesquisa, São Paulo, SP, Brazil
| | - R C Oliveira
- Department of Biological Sciences, Bauru School of Dentistry, University of São Paulo, Bauru, SP, Brazil
| |
Collapse
|
44
|
Effectiveness of a new dental implant bioactive surface: histological and histomorphometric comparative study in minipigs. Clin Oral Investig 2017; 22:1423-1432. [PMID: 29022215 DOI: 10.1007/s00784-017-2223-y] [Citation(s) in RCA: 7] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/29/2015] [Accepted: 09/27/2017] [Indexed: 01/10/2023]
Abstract
OBJECTIVES The objective of this study was to assess, by histomorphometric analysis, the degree of bone apposition on two types of dental implant's surfaces: a novel implant that combines Al2O3 abrasive particle blasting with thermochemical treatment (ContacTi), compared to a standard surface treatment obtained by sandblasting and acid etching (shot blasting). MATERIALS AND METHODS Twelve minipigs were used, placing the studied implants in the maxillae, and divided into three groups according to the time of sacrifice: 2, 4, and 8 weeks after implant placement. Histological and histomorphometric analyses were performed following standardized tissue polymerization, cutting, and staining and examined under optical and high-resolution electron microscope. RESULTS For all measurements, the novel surface presented higher levels of osseointegration as compared to the shot blasting surface. Bone to implant contact (BIC) in the maxillae for ContacTi presented values of 49.02, 83.20, and 85.58% at 2, 4, and 8 weeks, respectively, significantly higher compared to the shot blasting surface values of 39.32, 46.53, and 46.20% for the same time points. Bone area density (BAD) presented values of 26.52, 61.21, and 59.50% for ContacTi surface implants and 22.95, 36.26, and 49.50% for the shot blasted surface implants. Signs of osteoconductivity were observed in the ContacTi surfaces at 2 weeks. CONCLUSIONS The ContacTi surface achieved a faster growth of hard tissues around the implants, when compared to the shot blasting surface, and for all evaluated histomorphometric parameters, the values were higher at all measured time points. CLINICAL RELEVANCE ContacTi could be a new surface improving the osseointegration in oral implantology.
Collapse
|
45
|
Sivaraman K, Chopra A, Narayan AI, Balakrishnan D. Is zirconia a viable alternative to titanium for oral implant? A critical review. J Prosthodont Res 2017; 62:121-133. [PMID: 28827030 DOI: 10.1016/j.jpor.2017.07.003] [Citation(s) in RCA: 126] [Impact Index Per Article: 15.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/21/2017] [Revised: 06/22/2017] [Accepted: 07/11/2017] [Indexed: 02/04/2023]
Abstract
PURPOSE Titanium based implant systems, though considered as the gold standard for rehabilitation of edentulous spaces, have been criticized for many inherent flaws. The onset of hypersensitivity reactions, biocompatibility issues, and an unaesthetic gray hue have raised demands for more aesthetic and tissue compatible material for implant fabrication. Zirconia is emerging as a promising alternative to conventional Titanium based implant systems for oral rehabilitation with superior biological, aesthetics, mechanical and optical properties. This review aims to critically analyze and review the credibility of Zirconia implants as an alternative to Titanium for prosthetic rehabilitation. STUDY SELECTION The literature search for articles written in the English language in PubMed and Cochrane Library database from 1990 till December 2016. The following search terms were utilized for data search: "zirconia implants" NOT "abutment", "zirconia implants" AND "titanium implants" AND "osseointegration", "zirconia implants" AND compatibility. RESULTS The number of potential relevant articles selected were 47. All the human in vivo clinical, in vitro, animals' studies were included and discussed under the following subheadings: Chemical composition, structure and phases; Physical and mechanical properties; Aesthetic and optical properties; Osseointegration and biocompatibility; Surface modifications; Peri-implant tissue compatibility, inflammation and soft tissue healing, and long-term prognosis. CONCLUSIONS Zirconia implants are a promising alternative to titanium with a superior soft-tissue response, biocompatibility, and aesthetics with comparable osseointegration. However, further long-term longitudinal and comparative clinical trials are required to validate zirconia as a viable alternative to the titanium implant.
Collapse
Affiliation(s)
- Karthik Sivaraman
- Department of Prosthodontics, Manipal College of Dental Sciences, Manipal University, Manipal, 576104, India.
| | - Aditi Chopra
- Department of Periodontology, Manipal College of Dental Sciences, Manipal University, Manipal, India
| | - Aparna I Narayan
- Department of Prosthodontics, Manipal College of Dental Sciences, Manipal University, Manipal, 576104, India
| | - Dhanasekar Balakrishnan
- Department of Prosthodontics, Manipal College of Dental Sciences, Manipal University, Manipal, 576104, India
| |
Collapse
|
46
|
Osman RB, van der Veen AJ, Huiberts D, Wismeijer D, Alharbi N. 3D-printing zirconia implants; a dream or a reality? An in-vitro study evaluating the dimensional accuracy, surface topography and mechanical properties of printed zirconia implant and discs. J Mech Behav Biomed Mater 2017; 75:521-528. [PMID: 28846981 DOI: 10.1016/j.jmbbm.2017.08.018] [Citation(s) in RCA: 93] [Impact Index Per Article: 11.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/16/2017] [Revised: 08/12/2017] [Accepted: 08/14/2017] [Indexed: 11/29/2022]
Abstract
PURPOSE The aim of this study was to evaluate the dimensional accuracy, surface topography of a custom designed, 3D-printed zirconia dental implant and the mechanical properties of printed zirconia discs. MATERIALS AND METHODS A custom designed implant was 3D-printed in zirconia using digital light processing technique (DLP). The dimensional accuracy was assessed using the digital-subtraction technique. The mechanical properties were evaluated using biaxial flexure strength test. Three different build angles were adopted to print the specimens for the mechanical test; 0°(Vertical), 45° (Oblique) and 90°(Horizontal) angles. The surface topography, crystallographic phase structure and surface roughness were evaluated using scanning electron microscopy analysis (SEM), X-ray diffractometer and confocal microscopy respectively. RESULTS The printed implant was dimensionally accurate with a root mean square (RMSE) value of 0.1mm. The Weibull analysis revealed a statistically significant higher characteristic strength (1006.6MPa) of 0° printed specimens compared to the other two groups and no significant difference between 45° (892.2MPa) and 90° (866.7MPa) build angles. SEM analysis revealed cracks, micro-porosities and interconnected pores ranging in size from 196nm to 3.3µm. The mean Ra (arithmetic mean roughness) value of 1.59µm (±0.41) and Rq (root mean squared roughness) value of 1.94µm (±0.47) was found. A crystallographic phase of primarily tetragonal zirconia typical of sintered Yttria tetragonal stabilized zirconia (Y-TZP) was detected. CONCLUSIONS DLP prove to be efficient for printing customized zirconia dental implants with sufficient dimensional accuracy. The mechanical properties showed flexure strength close to those of conventionally produced ceramics. Optimization of the 3D-printing process parameters is still needed to improve the microstructure of the printed objects.
Collapse
Affiliation(s)
- Reham B Osman
- Department of Removable prosthodontics, Faculty of Dentistry, Cairo University, Egypt; Department of Oral Implantology and Prosthetic Dentistry, Academic Centre for Dentistry Amsterdam (ACTA), University of Amsterdam and Vrije Universiteit Amsterdam, Amsterdam, The Netherlands
| | - Albert J van der Veen
- Department of Physics and Medical Technology, VU University Medical Centre, Research Institute MOVE, Amsterdam, The Netherlands
| | - Dennis Huiberts
- Department of Oral Implantology and Prosthetic Dentistry, Academic Centre for Dentistry Amsterdam (ACTA), University of Amsterdam and Vrije Universiteit Amsterdam, Amsterdam, The Netherlands
| | - Daniel Wismeijer
- Department of Oral Implantology and Prosthetic Dentistry, Academic Centre for Dentistry Amsterdam (ACTA), University of Amsterdam and Vrije Universiteit Amsterdam, Amsterdam, The Netherlands
| | - Nawal Alharbi
- Department of Oral Implantology and Prosthetic Dentistry, Academic Centre for Dentistry Amsterdam (ACTA), University of Amsterdam and Vrije Universiteit Amsterdam, Amsterdam, The Netherlands; Prosthetic Dental Science Department, College of Dentistry, King Saud University, Riyadh, Saudi Arabia.
| |
Collapse
|
47
|
Kniha K, Kniha H, Möhlhenrich S, Milz S, Hölzle F, Modabber A. Papilla and alveolar crest levels in immediate versus delayed single-tooth zirconia implants. Int J Oral Maxillofac Surg 2017; 46:1039-1044. [DOI: 10.1016/j.ijom.2017.02.007] [Citation(s) in RCA: 12] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/21/2016] [Revised: 11/22/2016] [Accepted: 02/08/2017] [Indexed: 11/15/2022]
|
48
|
Benic GI, Thoma DS, Sanz-Martin I, Munoz F, Hämmerle CH, Cantalapiedra A, Fischer J, Jung RE. Guided bone regeneration at zirconia and titanium dental implants: a pilot histological investigation. Clin Oral Implants Res 2017; 28:1592-1599. [DOI: 10.1111/clr.13030] [Citation(s) in RCA: 11] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Accepted: 05/09/2017] [Indexed: 11/30/2022]
Affiliation(s)
- Goran I. Benic
- Clinic of Fixed and Removable Prosthodontics and Dental Material Science; Center of Dental Medicine; University of Zurich; Zurich Switzerland
| | - Daniel S. Thoma
- Clinic of Fixed and Removable Prosthodontics and Dental Material Science; Center of Dental Medicine; University of Zurich; Zurich Switzerland
| | | | - Fernando Munoz
- Faculty of Veterinary; University of Santiago de Compostela; Santiago Spain
| | - Christoph H.F. Hämmerle
- Clinic of Fixed and Removable Prosthodontics and Dental Material Science; Center of Dental Medicine; University of Zurich; Zurich Switzerland
| | | | - Jens Fischer
- Division of Dental Materials and Engineering; University of Basel; Basel Switzerland
| | - Ronald E. Jung
- Clinic of Fixed and Removable Prosthodontics and Dental Material Science; Center of Dental Medicine; University of Zurich; Zurich Switzerland
| |
Collapse
|
49
|
Bissinger O, Götz C, Jeschke A, Haller B, Wolff KD, Kaiser P, Kolk A. Comparison of contact radiographed and stained histological sections for osseointegration analysis of dental implants: an in vivo study. Oral Surg Oral Med Oral Pathol Oral Radiol 2017; 125:20-26. [PMID: 29079369 DOI: 10.1016/j.oooo.2017.06.118] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/02/2017] [Revised: 05/15/2017] [Accepted: 06/19/2017] [Indexed: 11/16/2022]
Abstract
OBJECTIVES Histology is still regarded as the gold-standard to determine bone implant contact (BIC) as a parameter representing implant stability. As the further processing of cut slices for contact radiography (CR) to stained and polished histological sections is time consuming and error prone, our aim was to assess agreement between CR and Giemsa-eosin (GE) stained sections with regard to dental implants. STUDY DESIGN Threaded dental titanium implants (n = 54) from the maxillae of Goettingen minipigs were evaluated. After 28 and 56 days, BIC and the ratio of bone volume to total volume (BV/TV; 1000 μm) were determined on the same sections by using CR and GE staining, and the results were compared. RESULTS Moderate differences for BIC (0.6%; P = .53) and BV/TV (1.3%; P = .01) between the methods were determined, in which CR overestimated BIC and BV/TV. A strong correlation was seen between the modalities concerning BIC (28 days: r = 0.84; 56 days: r = 0.85; total: r = 0.85) and BV/TV (r = 0.96; r = 0.94; r = 0.96; all: P < .0001). CONCLUSIONS CR enabled determination of the bone-to-implant interface in comparison with GE-stained sections. BIC and BV/TV were slightly overestimated but correlated strongly between the methods. Therefore, if BIC and BV/TV are sufficient endpoints, CR is adequate and no further preparation and staining are necessary.
Collapse
Affiliation(s)
- Oliver Bissinger
- Department of Oral and Maxillofacial Surgery, Klinikum rechts der Isar der Technischen Universität München, Munich, Germany.
| | - Carolin Götz
- Department of Oral and Maxillofacial Surgery, Klinikum rechts der Isar der Technischen Universität München, Munich, Germany
| | - Anke Jeschke
- Department of Osteology and Biomechanics, University Medical Center Hamburg-Eppendorf, Hamburg, Germany
| | - Bernhard Haller
- Institute of Medical Statistics and Epidemiology, Klinikum rechts der Isar der Technischen Universität München, Munich, Germany
| | - Klaus-Dietrich Wolff
- Department of Oral and Maxillofacial Surgery, Klinikum rechts der Isar der Technischen Universität München, Munich, Germany
| | - Pascal Kaiser
- Department of Oral and Maxillofacial Surgery, Klinikum rechts der Isar der Technischen Universität München, Munich, Germany; Department of Oral and Maxillofacial Plastic Surgery, University Hospital Würzburg, Würzburg, Germany
| | - Andreas Kolk
- Department of Oral and Maxillofacial Surgery, Klinikum rechts der Isar der Technischen Universität München, Munich, Germany
| |
Collapse
|
50
|
Kuo TF, Lu HC, Tseng CF, Yang JC, Wang SF, Yang TCK, Lee SY. Evaluation of Osseointegration in Titanium and Zirconia-Based Dental Implants with Surface Modification in a Miniature Pig Model. J Med Biol Eng 2017. [DOI: 10.1007/s40846-017-0230-8] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/29/2022]
|