1
|
ATP-Independent Water-Soluble Luciferins Enable Non-Invasive High-Speed Video-Rate Bioluminescence Imaging of Mice. BIORXIV : THE PREPRINT SERVER FOR BIOLOGY 2024:2024.04.30.591933. [PMID: 38746394 PMCID: PMC11092570 DOI: 10.1101/2024.04.30.591933] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/16/2024]
Abstract
NanoLuc luciferase and its derivatives are attractive bioluminescent reporters recognized for their efficient photon production and ATP independence. However, utilizing them for in vivo imaging poses notable challenges. Low substrate solubility has been a prominent problem, limiting in vivo brightness, while substrate instability hampers consistent results and handling. To address these issues, we developed a range of caged PEGylated luciferins with improved stability and water solubility of up to 25 mM, resulting in substantial bioluminescence increases in mouse models. This advancement has created the brightest and most sensitive luciferase-luciferin combination, enabling high-speed video-rate imaging of freely moving mice with brain-expressed luciferase. Furthermore, we developed a bioluminescent Ca 2+ indicator with exceptional sensitivity to physiological Ca 2+ changes and paired it with a new substrate to showcase non-invasive, video-rate imaging of Ca 2+ activity in a defined brain region in awake mice. These innovative substrates and the Ca 2+ indicator are poised to become invaluable resources for biological and biomedical fields.
Collapse
|
2
|
Rainbow trout (Oncorhynchus mykiss, Walbaum 1792) adenocarcinoma investigation with various diagnostic imaging techniques. JOURNAL OF FISH DISEASES 2024:e13951. [PMID: 38587087 DOI: 10.1111/jfd.13951] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 01/27/2024] [Revised: 02/25/2024] [Accepted: 02/29/2024] [Indexed: 04/09/2024]
Abstract
Diagnostic imaging techniques provide a new aspect of the ante-mortem and post-mortem diagnostics in fish medicine. Ultrasonography, computed tomography (CT) and magnetic resonance imaging (MRI) can provide more information about the internal organs and pathognomic lesions. The authors used diagnostic imaging techniques to evaluate and describe the neoplastic malformation in a 3-year-old female rainbow trout (Oncorhynchus mykiss). The fish was examined with Siemens Somatom Definition AS + CT scanner and Siemens Biograph mMR scanner. The animal was lethargic and showed anorectic signs and muscular dystrophy. During the post-mortem investigation, histopathology and immunohistochemistry were also performed allowing us to identify the neoplasms. The results showed a large soft tissue mass in the first mid-intestine segment, which proved to be an adenocarcinoma. This subsequently led to digestion problems and absorption disorders. Immunohistochemically, neoplastic cells of carcinoma revealed E-cadherin and pancytokeratin positivity. This is the first study to report the use of MRI and CT for studying gastrointestinal adenocarcinoma in rainbow trout.
Collapse
|
3
|
A single crystal row-column-array for 3D ultrasound imaging. ULTRASONICS 2024; 139:107289. [PMID: 38492351 DOI: 10.1016/j.ultras.2024.107289] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 10/01/2023] [Revised: 03/03/2024] [Accepted: 03/03/2024] [Indexed: 03/18/2024]
Abstract
In vivo 3D ultrasound imaging with 2D-array transducers is of great importance for both clinical application and biomedical research, but it is complicated in fabrication and also very expensive in hardware due to thousands of electronic channels. In this work, we demonstrate a new fabrication process of 7-MHz 128 + 128 elements row-column-array (RCA) transducer with relaxor ferroelectric PMN-0.28PT single crystal. With piezoelectric single crystal and improved acoustic matching, the optimized performance of -6 dB bandwidth of ∼82 % and insertion loss of -44.6 dB is achieved. The axial and lateral imaging resolutions at different depth of the RCA transducer are quantified by the point spread function (PSF), and the results are respectively 0.20 mm and 0.41 mm at the depth of 7.7 mm, and 0.22 mm and 0.47 mm at the depth of 16.7 mm. The transducer is validated experimentally on a hyperechoic phantom, and 3D view and slices of B-mode images are obtained. The experimental results indicate that our developed RCA transducer can obtain high-quality 3D ultrasound images, demonstrating great potential on ultrafast 3D and functional imaging.
Collapse
|
4
|
Development of an integrated dual-modality 3D bioluminescence tomography and ultrasound imaging system for small animal tumor imaging. OPTICS EXPRESS 2024; 32:5607-5620. [PMID: 38439282 DOI: 10.1364/oe.507659] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 10/25/2023] [Accepted: 01/16/2024] [Indexed: 03/06/2024]
Abstract
Ultrasound (US) is a valuable tool for imaging soft tissue and visualizing tumor contours. Taking the benefits of US, we presented an integrated dual-modality imaging system in this paper that achieves three-dimensional (3D) bioluminescence tomography (BLT) with multi-view bioluminescence images and 3D US imaging. The purpose of this system is to perform non-invasive, long-term monitoring of tumor growth in 3D images. US images can enhance the accuracy of the 3D BLT reconstruction and the bioluminescence dose within an object. Furthermore, an integrated co-registered scanning geometry was used to capture the fused BLT and US images. We validated the system with an in vivo experiment involving tumor-bearing mice. The results demonstrated the feasibility of reconstructing 3D BLT images in the tumor region using 3D US images. We used the dice coefficient and locational error to evaluate the similarity between the reconstructed source region and the actual source region. The dice coefficient was 88.5%, and the locational error was 0.4 mm when comparing the BLT and 3D US images. The hybrid BLT/US system could provide significant benefits for reconstructing the source of tumor location and conducting quantitative analysis of tumor size.
Collapse
|
5
|
Spatiotemporal image reconstruction to enable high-frame-rate dynamic photoacoustic tomography with rotating-gantry volumetric imagers. JOURNAL OF BIOMEDICAL OPTICS 2024; 29:S11516. [PMID: 38249994 PMCID: PMC10798269 DOI: 10.1117/1.jbo.29.s1.s11516] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 09/30/2023] [Revised: 11/22/2023] [Accepted: 12/20/2023] [Indexed: 01/23/2024]
Abstract
Significance Dynamic photoacoustic computed tomography (PACT) is a valuable imaging technique for monitoring physiological processes. However, current dynamic PACT imaging techniques are often limited to two-dimensional spatial imaging. Although volumetric PACT imagers are commercially available, these systems typically employ a rotating measurement gantry in which the tomographic data are sequentially acquired as opposed to being acquired simultaneously at all views. Because the dynamic object varies during the data-acquisition process, the sequential data-acquisition process poses substantial challenges to image reconstruction associated with data incompleteness. The proposed image reconstruction method is highly significant in that it will address these challenges and enable volumetric dynamic PACT imaging with existing preclinical imagers. Aim The aim of this study is to develop a spatiotemporal image reconstruction (STIR) method for dynamic PACT that can be applied to commercially available volumetric PACT imagers that employ a sequential scanning strategy. The proposed reconstruction method aims to overcome the challenges caused by the limited number of tomographic measurements acquired per frame. Approach A low-rank matrix estimation-based STIR (LRME-STIR) method is proposed to enable dynamic volumetric PACT. The LRME-STIR method leverages the spatiotemporal redundancies in the dynamic object to accurately reconstruct a four-dimensional (4D) spatiotemporal image. Results The conducted numerical studies substantiate the LRME-STIR method's efficacy in reconstructing 4D dynamic images from tomographic measurements acquired with a rotating measurement gantry. The experimental study demonstrates the method's ability to faithfully recover the flow of a contrast agent with a frame rate of 10 frames per second, even when only a single tomographic measurement per frame is available. Conclusions The proposed LRME-STIR method offers a promising solution to the challenges faced by enabling 4D dynamic imaging using commercially available volumetric PACT imagers. By enabling accurate STIRs, this method has the potential to significantly advance preclinical research and facilitate the monitoring of critical physiological biomarkers.
Collapse
|
6
|
High-resolution X-Ray imaging of small animal samples based on Commercial-Off-The-Shelf CMOS image sensors. JOURNAL OF X-RAY SCIENCE AND TECHNOLOGY 2024; 32:355-367. [PMID: 38427532 DOI: 10.3233/xst-230232] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 03/03/2024]
Abstract
An automated system for acquiring microscopic-resolution radiographic images of biological samples was developed. Mass-produced, low-cost, and easily automated components were used, such as Commercial-Off-The-Self CMOS image sensors (CIS), stepper motors, and control boards based on Arduino and RaspberryPi. System configuration, imaging protocols, and Image processing (filtering and stitching) were defined to obtain high-resolution images and for successful computational image reconstruction. Radiographic images were obtained for animal samples including the widely used animal models zebrafish (Danio rerio) and the fruit-fly (Drosophila melanogaster), as well as other small animal samples. The use of phosphotungstic acid (PTA) as a contrast agent was also studied. Radiographic images with resolutions of up to (7±0.6)μm were obtained, making this system comparable to commercial ones. This work constitutes a starting point for the development of more complex systems such as X-ray attenuation micro-tomography systems based on low-cost off-the-shelf technology. It will also bring the possibility to expand the studies that can be carried out with small animal models at many institutions (mostly those working on tight budgets), particularly those on the effects of ionizing radiation and absorption of heavy metal contaminants in animal tissues.
Collapse
|
7
|
Nanotheranostics: Molecular Diagnostics and Nanotherapeutic Evaluation by Photoacoustic/Ultrasound Imaging in Small Animals. Mol Pharm 2023; 20:6010-6034. [PMID: 37931040 DOI: 10.1021/acs.molpharmaceut.3c00708] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/08/2023]
Abstract
Nanotheranostics is a rapidly developing field that integrates nanotechnology, diagnostics, and therapy to provide novel methods for imaging and treating wide categories of diseases. Targeted nanotheranostics offers a platform for the precise delivery of theranostic agents, and their therapeutic outcomes are monitored in real-time. Presently, in vivo magnetic resonance imaging, fluorescence imaging, ultrasound imaging, and photoacoustic imaging (PAI), etc. are noninvasive imaging techniques that are preclinically available for the imaging and tracking of therapeutic outcomes in small animals. Additionally, preclinical imaging is essential for drug development, phenotyping, and understanding disease stage progression and its associated mechanisms. Small animal ultrasound imaging is a rapidly developing imaging technique for theranostics applications due to its merits of being nonionizing, real-time, portable, and able to penetrate deep tissues. Recently, different types of ultrasound contrast agents have been explored, such as microbubbles, echogenic exosomes, gas-vesicles, and nanoparticles-based contrast agents. Moreover, an optical image obtained through photoacoustic imaging is a noninvasive imaging technique that creates ultrasonic waves when pulsed laser light is used to expose an object and creates a picture of the tissue's distribution of light energy absorption on the object. Contrast agents for photoacoustic imaging may be endogenous (hemoglobin, melanin, and DNA/RNA) or exogenous (dyes and nanomaterials-based contrast agents). The integration of nanotheranostics with photoacoustic and ultrasound imaging allows simultaneous imaging and treatment of diseases in small animals, which provides essential information about the drug response and the disease progression. In this review, we have covered various endogenous and exogenous contrast agents for ultrasound and photoacoustic imaging. Additionally, we have discussed various drug delivery systems integrated with contrast agents for theranostic application. Further, we have briefly discussed the current challenges associated with ultrasound and photoacoustic imaging.
Collapse
|
8
|
Community Survey Results Show that Standardisation of Preclinical Imaging Techniques Remains a Challenge. Mol Imaging Biol 2023; 25:560-568. [PMID: 36482032 PMCID: PMC10172263 DOI: 10.1007/s11307-022-01790-6] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/06/2022] [Revised: 11/15/2022] [Accepted: 11/16/2022] [Indexed: 12/13/2022]
Abstract
PURPOSE To support acquisition of accurate, reproducible and high-quality preclinical imaging data, various standardisation resources have been developed over the years. However, it is unclear the impact of those efforts in current preclinical imaging practices. To better understand the status quo in the field of preclinical imaging standardisation, the STANDARD group of the European Society of Molecular Imaging (ESMI) put together a community survey and a forum for discussion at the European Molecular Imaging Meeting (EMIM) 2022. This paper reports on the results from the STANDARD survey and the forum discussions that took place at EMIM2022. PROCEDURES The survey was delivered to the community by the ESMI office and was promoted through the Society channels, email lists and webpages. The survey contained seven sections organised as generic questions and imaging modality-specific questions. The generic questions focused on issues regarding data acquisition, data processing, data storage, publishing and community awareness of international guidelines for animal research. Specific questions on practices in optical imaging, PET, CT, SPECT, MRI and ultrasound were further included. RESULTS Data from the STANDARD survey showed that 47% of survey participants do not have or do not know if they have QC/QA guidelines at their institutes. Additionally, a large variability exists in the ways data are acquired, processed and reported regarding general aspects as well as modality-specific aspects. Moreover, there is limited awareness of the existence of international guidelines on preclinical (imaging) research practices. CONCLUSIONS Standardisation of preclinical imaging techniques remains a challenge and hinders the transformative potential of preclinical imaging to augment biomedical research pipelines by serving as an easy vehicle for translation of research findings to the clinic. Data collected in this project show that there is a need to promote and disseminate already available tools to standardise preclinical imaging practices.
Collapse
|
9
|
Intraoral Ultrasonography for Periodontal Tissue Exploration: A Review. Diagnostics (Basel) 2023; 13:diagnostics13030365. [PMID: 36766470 PMCID: PMC9914868 DOI: 10.3390/diagnostics13030365] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/30/2022] [Revised: 01/09/2023] [Accepted: 01/16/2023] [Indexed: 01/21/2023] Open
Abstract
This systematic review aims to investigate the possibilities of ultrasound imaging in the field of periodontal tissues exploration to visualize periodontal anatomical structures and to assess reliability in clinical evaluation using the PRISMA guidelines. An electronic search through the MEDLINE database was realized to identify studies that have explored ultrasonography in the field of periodontal imaging published from 2000 to March 2022. The search resulted in 245 records; after exclusions, a total of 15 papers were included in the present review. Various publications have shown the possibility of using intraoral ultrasound for a precise exploration of intraoral tissues and to perform measurements of periodontal structures. Studies argue that ultrasounds open the prospect of a complete paradigm shift on the diagnosis and follow-up of periodontal disease. However, there is currently no clinical device dedicated to periodontal ultrasound. This field is still under-studied, and studies are needed to explore the large field of applications from periodontal assessment to treatment reassessment, including surgery. Researchers should focus their efforts to develop special intraoral ultrasound device and explore the possibilities of clinical periodontal applications.
Collapse
|
10
|
20-MHz phased array ultrasound transducer for in vivo ultrasound imaging of small animals. ULTRASONICS 2022; 126:106821. [PMID: 35988512 DOI: 10.1016/j.ultras.2022.106821] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 05/07/2021] [Revised: 07/16/2022] [Accepted: 08/04/2022] [Indexed: 06/15/2023]
Abstract
In vivo ultrasound imaging with phased array transducers is of great importance for both clinical application and biomedical research. In this work, relaxor ferroelectric PMN-0.28PT single crystal with very high piezoelectric constant d33 ≥ 2000 pC/N and electromechanical coupling coefficient k33 ∼ 0.92 is used to fabricate high-frequency phased array transducers. A 128-element 20-MHz phased array transducer is successfully fabricated, and the optimized performance of -6 dB average bandwidth of ∼ 84 % and insertion loss of -43 dB are achieved. The axial and lateral imaging resolutions of the transducer are determined to be 81 µm and 243 µm, respectively. With Verasonics image platform, in vivo fisheye images are acquired, demonstrating the potential application of our developed high-frequency phased array transducer for biomedical research on small animals.
Collapse
|
11
|
Understanding the importance of quality control and quality assurance in preclinical PET/CT imaging. EJNMMI Phys 2022; 9:77. [PMID: 36315337 PMCID: PMC9622967 DOI: 10.1186/s40658-022-00503-w] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/10/2021] [Accepted: 10/20/2022] [Indexed: 11/12/2022] Open
Abstract
The fundamental principle of experimental design is to ensure efficiency and efficacy of the performed experiments. Therefore, it behoves the researcher to gain knowledge of the technological equipment to be used. This should include an understanding of the instrument quality control and assurance requirements to avoid inadequate or spurious results due to instrumentation bias whilst improving reproducibility. Here, the important role of preclinical positron emission tomography/computed tomography and the scanner's required quality control and assurance is presented along with the suggested guidelines for quality control and assurance. There are a multitude of factors impeding the continuity and reproducibility of preclinical research data within a single laboratory as well as across laboratories. A more robust experimental design incorporating validation or accreditation of the scanner performance can reduce inconsistencies. Moreover, the well-being and welfare of the laboratory animals being imaged is prime justification for refining experimental designs to include verification of instrumentation quality control and assurance. Suboptimal scanner performance is not consistent with the 3R principle (Replacement, Reduction, and Refinement) and potentially subjects animals to unnecessary harm. Thus, quality assurance and control should be of paramount interest to any scientist conducting animal studies. For this reason, through this work, we intend to raise the awareness of researchers using PET/CT regarding quality control/quality assurance (QC/QA) guidelines and instil the importance of confirming that these are routinely followed. We introduce a basic understanding of the PET/CT scanner, present the purpose of QC/QA as well as provide evidence of imaging data biases caused by lack of QC/QA. This is shown through a review of the literature, QC/QA accepted standard protocols and our research. We also want to encourage researchers to have discussions with the PET/CT facilities manager and/or technicians to develop the optimal designed PET/CT experiment for obtaining their scientific objective. Additionally, this work provides an easy gateway to multiple resources not only for PET/CT knowledge but for guidelines and assistance in preclinical experimental design to enhance scientific integrity of the data and ensure animal welfare.
Collapse
|
12
|
Applications of Contrast-Enhanced Ultrasound in Splenic Studies of Dogs and Cats. Animals (Basel) 2022; 12:ani12162104. [PMID: 36009694 PMCID: PMC9404716 DOI: 10.3390/ani12162104] [Citation(s) in RCA: 2] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/14/2022] [Revised: 07/29/2022] [Accepted: 08/11/2022] [Indexed: 11/25/2022] Open
Abstract
Simple Summary Contrast-enhanced ultrasound (CEUS) is a noninvasive imaging technique that has become a reliable tool for identifying and monitoring lesions in both human and animals. In the last decade, its use in veterinary diagnostic imaging has gained increasing importance, and it can be reliable in everyday clinical practice. However, there is a lack of reviews describing existing CEUS results in the study of splenic lesions, which is of particular importance in dogs and cats. This information is important for validating its efficacy, to facilitate decision making related to sampling procedures and diagnosis, or even as a means to select CEUS as an alternative diagnostic tool in specific cases. Our goal was to review the existing studies of CEUS applications for splenic ultrasound studies in cats and dogs, present these results in a systematic manner, and combine this information into practical guidelines that can be used to help diagnosis and interpretation in both clinical cases and research. Abstract Contrast-enhanced ultrasound (CEUS) is an emerging technology in veterinary medicine involving the administration of intravenous contrast agents, and it is increasingly recognized for its high potential as a diagnostic imaging tool for small animals. This exam is easy and quick to perform, safe and reliable, and allows for the differentiation of lesions. It permits the identification of lesions that may require more invasive procedures, from those that can be safely dismissed to those that can be followed-up with ultrasound imaging. Although it has been extensively reviewed for use in human medicine, there is an overall lack of information about the application of this technique for cats and dogs, particularly in splenic studies, which can be particularly important for small animals. The present review describes and summarizes the CEUS applications used for splenic analysis in cats and dogs, providing a basic overview of CEUS technology with examples of common and uncommon features of focal splenic lesions. It also systematically gathers the results obtained for benign and malignant splenic lesions described in the literature, whilst providing guidelines for their interpretation. Furthermore, it presents the advantages of using CEUS for splenic analysis in cats and dogs and the main factors that may influence the quality of the imaging and the accuracy of the diagnosis. This type of knowledge can be used to provide a framework to help veterinarians make informed decisions regarding the use of this emerging technique for splenic lesions, guiding their interpretation of CEUS findings in the splenic ultrasounds of cats and dogs.
Collapse
|
13
|
Contrast Agents for Photoacoustic Imaging: A Review Focusing on the Wavelength Range. BIOSENSORS 2022; 12:bios12080594. [PMID: 36004990 PMCID: PMC9406114 DOI: 10.3390/bios12080594] [Citation(s) in RCA: 13] [Impact Index Per Article: 6.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 07/19/2022] [Revised: 07/29/2022] [Accepted: 07/31/2022] [Indexed: 11/16/2022]
Abstract
Photoacoustic imaging using endogenous chromophores as a contrast has been widely applied in biomedical studies owing to its functional imaging capability at the molecular level. Various exogenous contrast agents have also been investigated for use in contrast-enhanced imaging and functional analyses. This review focuses on contrast agents, particularly in the wavelength range, for use in photoacoustic imaging. The basic principles of photoacoustic imaging regarding light absorption and acoustic release are introduced, and the optical characteristics of tissues are summarized according to the wavelength region. Various types of contrast agents, including organic dyes, semiconducting polymeric nanoparticles, gold nanoparticles, and other inorganic nanoparticles, are explored in terms of their light absorption range in the near-infrared region. An overview of the contrast-enhancing capacity and other functional characteristics of each agent is provided to help researchers gain insights into the development of contrast agents in photoacoustic imaging.
Collapse
|
14
|
Looking deep inside tissue with photoacoustic molecular probes: a review. JOURNAL OF BIOMEDICAL OPTICS 2022; 27:070901. [PMID: 36451698 PMCID: PMC9307281 DOI: 10.1117/1.jbo.27.7.070901] [Citation(s) in RCA: 5] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 04/29/2022] [Accepted: 07/01/2022] [Indexed: 05/19/2023]
Abstract
Significance Deep tissue noninvasive high-resolution imaging with light is challenging due to the high degree of light absorption and scattering in biological tissue. Photoacoustic imaging (PAI) can overcome some of the challenges of pure optical or ultrasound imaging to provide high-resolution deep tissue imaging. However, label-free PAI signals from light absorbing chromophores within the tissue are nonspecific. The use of exogeneous contrast agents (probes) not only enhances the imaging contrast (and imaging depth) but also increases the specificity of PAI by binding only to targeted molecules and often providing signals distinct from the background. Aim We aim to review the current development and future progression of photoacoustic molecular probes/contrast agents. Approach First, PAI and the need for using contrast agents are briefly introduced. Then, the recent development of contrast agents in terms of materials used to construct them is discussed. Then, various probes are discussed based on targeting mechanisms, in vivo molecular imaging applications, multimodal uses, and use in theranostic applications. Results Material combinations are being used to develop highly specific contrast agents. In addition to passive accumulation, probes utilizing activation mechanisms show promise for greater controllability. Several probes also enable concurrent multimodal use with fluorescence, ultrasound, Raman, magnetic resonance imaging, and computed tomography. Finally, targeted probes are also shown to aid localized and molecularly specific photo-induced therapy. Conclusions The development of contrast agents provides a promising prospect for increased contrast, higher imaging depth, and molecularly specific information. Of note are agents that allow for controlled activation, explore other optical windows, and enable multimodal use to overcome some of the shortcomings of label-free PAI.
Collapse
|
15
|
A Review and Case Study of 3D Imaging Modalities for Female Amniote Reproductive Anatomy. Integr Comp Biol 2022; 62:icac027. [PMID: 35536568 PMCID: PMC10570564 DOI: 10.1093/icb/icac027] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/28/2022] [Revised: 04/20/2022] [Indexed: 11/13/2022] Open
Abstract
Recent advances in non-invasive imaging methods have revitalised the field of comparative anatomy, and reproductive anatomy has been no exception. The reproductive systems of female amniotes present specific challenges, namely their often internal "hidden" anatomy. Quantifying female reproductive systems is crucial to recognising reproductive pathologies, monitoring menstrual cycles, and understanding copulatory mechanics. Here we conduct a review of the application of non-invasive imaging techniques to female amniote reproductive anatomy. We introduce the commonly used imaging modalities of computed tomography (CT) and magnetic resonance imaging (MRI), highlighting their advantages and limitations when applied to female reproductive tissues, and make suggestions for future advances. We also include a case study of micro CT and MRI, along with their associated staining protocols, applied to cadavers of female adult stoats (Mustela erminea). In doing so, we will progress the discussion surrounding the imaging of female reproductive anatomy, whilst also impacting the fields of sexual selection research and comparative anatomy more broadly.
Collapse
|
16
|
Abstract
Photoacoustic imaging has drawn a significant amount of attention due to its unique capacity for functional, metabolic, and molecular imaging, which is achieved by the combination of optical excitation and acoustic detection. With both strengths of light and ultrasound, photoacoustic images can provide strong optical contrast at high ultrasound resolution in deep tissue. As photoacoustic imaging can be used to visualize complementary information to ultrasound imaging using the same data acquisition process, several studies have been conducted on combining photoacoustic imaging with existing clinical ultrasound systems. This review highlights our development of a photoacoustic/ultrasound dual-modal imaging system, various features and functionalities implemented for clinical translation, and preclinical/clinical studies performed by using the systems.
Collapse
|
17
|
Hydrogen Sulfide: An Emerging Precision Strategy for Gas Therapy. Adv Healthc Mater 2022; 11:e2101984. [PMID: 34788499 DOI: 10.1002/adhm.202101984] [Citation(s) in RCA: 30] [Impact Index Per Article: 15.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/17/2021] [Revised: 11/06/2021] [Indexed: 12/13/2022]
Abstract
Advances in nanotechnology have enabled the rapid development of stimuli-responsive therapeutic nanomaterials for precision gas therapy. Hydrogen sulfide (H2 S) is a significant gaseous signaling molecule with intrinsic biochemical properties, which exerts its various physiological effects under both normal and pathological conditions. Various nanomaterials with H2 S-responsive properties, as new-generation therapeutic agents, are explored to guide therapeutic behaviors in biological milieu. The cross disciplinary of H2 S is an emerging scientific hotspot that studies the chemical properties, biological mechanisms, and therapeutic effects of H2 S. This review summarizes the state-of-art research on H2 S-related nanomedicines. In particular, recent advances in H2 S therapeutics for cancer, such as H2 S-mediated gas therapy and H2 S-related synergistic therapies (combined with chemotherapy, photodynamic therapy, photothermal therapy, and chemodynamic therapy) are highlighted. Versatile imaging techniques for real-time monitoring H2 S during biological diagnosis are reviewed. Finally, the biosafety issues, current challenges, and potential possibilities in the evolution of H2 S-based therapy that facilitate clinical translation to patients are discussed.
Collapse
|
18
|
Review on Optical Imaging Techniques for Multispectral Analysis of Nanomaterials. Nanotheranostics 2022; 6:50-61. [PMID: 34976580 PMCID: PMC8671957 DOI: 10.7150/ntno.63222] [Citation(s) in RCA: 6] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/27/2021] [Accepted: 07/11/2021] [Indexed: 11/26/2022] Open
Abstract
Biomedical imaging is an essential tool for investigating biological responses in vivo. Among the several imaging techniques, optical imaging systems with multispectral analysis of nanoparticles have been widely investigated due to their ability to distinguish the substances in biological tissues in vivo. This review article focus on multispectral optical imaging techniques that can provide molecular functional information. We summarize the basic principle of the spectral unmixing technique that enables the delineation of optical chromophores. Then, we explore the principle, typical system configuration, and biomedical applications of the representative optical imaging techniques, which are fluorescence imaging, two-photon microscopy, and photoacoustic imaging. The results in the recent studies show the great potential of the multispectral analysis techniques for monitoring responses of biological systems in vivo.
Collapse
|
19
|
Vascular Imaging in Small Animals Using Clinical Ultrasound Scanners. Methods Mol Biol 2021. [PMID: 34591309 DOI: 10.1007/978-1-0716-1708-3_16] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register]
Abstract
Conventional ultrasound with frequency (2-15 MHz) has been a global diagnostic and therapeutic tool in clinical medicine, and high-frequency ultrasound (>30 MHz) has been a powerful investigative device for preclinical studies such as cardiovascular research. In this chapter, we describe the use of conventional ultrasound with a 2.5-10 MHz transducer as an investigative device for the measurement/detection of blood flow in rabbit model. The chapter will describe the procedures for the preparation of sonographer, imaging locations, and the details of the rabbits used as well as detailed imaging steps for the preoperative, immediately after operation, and postoperative follow-up ultrasound for vascular surgery, using a vascular graft implantation as an example. We also provide useful notes to avoid pitfalls for successful imaging. The overall goal of this chapter is to deliver the steps in using low-cost, non-invasive, and highly versatile clinical ultrasound imaging in preclinical small animal testing.
Collapse
|
20
|
A Versatile Multichannel Instrument for Measurement of Ratiometric Fluorescence Intensity and Phosphorescence Lifetime. IEEE ACCESS : PRACTICAL INNOVATIONS, OPEN SOLUTIONS 2021; 9:103835-103849. [PMID: 34858770 PMCID: PMC8635115 DOI: 10.1109/access.2021.3098777] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/13/2023]
Abstract
Optical biosensing is being actively investigated for minimally-invasive monitoring of key biomarkers both in vitro and in vivo. However, typical benchtop instruments are not portable and are not well suited to high-throughput, real-time analysis. This paper presents a versatile multichannel instrument for measurement of emission intensity and lifetime values arising from luminescent biosensor materials. A detailed design description of the opto-electronic hardware as well as the control software is provided, elaborating a flexible, user-configurable system that may be customized or duplicated for a wide range of applications. This article presents experimental measurements that prove the in vitro and in vivo functionality of the system. Such tools may be adopted for many research and development purposes, including evaluation of new biosensor materials, and may also serve as prototypes for future miniaturized handheld or wearable devices.
Collapse
|
21
|
Abstract
Neuroscience has seen substantial development in non-invasive methods available for investigating the living human brain. However, these tools are limited to coarse macroscopic measures of neural activity that aggregate the diverse responses of thousands of cells. To access neural activity at the cellular and circuit level, researchers instead rely on invasive recordings in animals. Recent advances in invasive methods now permit large-scale recording and circuit-level manipulations with exquisite spatio-temporal precision. Yet, there has been limited progress in relating these microcircuit measures to complex cognition and behaviour observed in humans. Contemporary neuroscience thus faces an explanatory gap between macroscopic descriptions of the human brain and microscopic descriptions in animal models. To close the explanatory gap, we propose adopting a cross-species approach. Despite dramatic differences in the size of mammalian brains, this approach is broadly justified by preserved homology. Here, we outline a three-armed approach for effective cross-species investigation that highlights the need to translate different measures of neural activity into a common space. We discuss how a cross-species approach has the potential to transform basic neuroscience while also benefiting neuropsychiatric drug development where clinical translation has, to date, seen minimal success. This article is part of the theme issue 'Key relationships between non-invasive functional neuroimaging and the underlying neuronal activity'.
Collapse
|
22
|
Role of Nuclear Imaging to Understand the Neural Substrates of Brain Disorders in Laboratory Animals: Current Status and Future Prospects. Front Behav Neurosci 2020; 14:596509. [PMID: 33362486 PMCID: PMC7759612 DOI: 10.3389/fnbeh.2020.596509] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/20/2020] [Accepted: 11/23/2020] [Indexed: 12/18/2022] Open
Abstract
Molecular imaging, which allows the real-time visualization, characterization and measurement of biological processes, is becoming increasingly used in neuroscience research. Scintigraphy techniques such as single photon emission computed tomography (SPECT) and positron emission tomography (PET) provide qualitative and quantitative measurement of brain activity in both physiological and pathological states. Laboratory animals, and rodents in particular, are essential in neuroscience research, providing plenty of models of brain disorders. The development of innovative high-resolution small animal imaging systems together with their radiotracers pave the way to the study of brain functioning and neurotransmitter release during behavioral tasks in rodents. The assessment of local changes in the release of neurotransmitters associated with the performance of a given behavioral task is a turning point for the development of new potential drugs for psychiatric and neurological disorders. This review addresses the role of SPECT and PET small animal imaging systems for a better understanding of brain functioning in health and disease states. Brain imaging in rodent models faces a series of challenges since it acts within the boundaries of current imaging in terms of sensitivity and spatial resolution. Several topics are discussed, including technical considerations regarding the strengths and weaknesses of both technologies. Moreover, the application of some of the radioligands developed for small animal nuclear imaging studies is discussed. Then, we examine the changes in metabolic and neurotransmitter activity in various brain areas during task-induced neural activation with special regard to the imaging of opioid, dopaminergic and cannabinoid receptors. Finally, we discuss the current status providing future perspectives on the most innovative imaging techniques in small laboratory animals. The challenges and solutions discussed here might be useful to better understand brain functioning allowing the translation of preclinical results into clinical applications.
Collapse
|
23
|
Longitudinal In-Vivo X-Ray Fluorescence Computed Tomography With Molybdenum Nanoparticles. IEEE TRANSACTIONS ON MEDICAL IMAGING 2020; 39:3910-3919. [PMID: 32746133 DOI: 10.1109/tmi.2020.3007165] [Citation(s) in RCA: 12] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/23/2023]
Abstract
X-ray fluorescence computed tomography (XFCT) with nanoparticles (NPs) as contrast agents shows potential for molecular biomedical imaging with higher spatial resolution than present methods. To date the technique has been demonstrated on phantoms and mice, however, parameters such as radiation dose, exposure times and sensitivity have not yet allowed for high-spatial-resolution in vivo longitudinal imaging, i.e., imaging of the same animal at different time points. Here we show in vivo XFCT with spatial resolution in the 200- [Formula: see text] range in a proof-of-principle longitudinal study where mice are imaged five times each during an eight-week period following tail-vein injection of NPs. We rely on a 24 keV x-ray pencil-beam-based excitation of in-house-synthesized molybdenum oxide NPs (MoO2) to provide the high signal-to-background x-ray fluorescence detection necessary for XFCT imaging with low radiation dose and short exposure times. We quantify the uptake and clearance of NPs in vivo through imaging, and monitor animal well-being over the course of the study with support from histology and DNA stability analysis to assess the impact of x-ray exposure and NPs on animal welfare. We conclude that the presented imaging arrangement has potential for in vivo longitudinal studies, putting emphasis on designing biocompatible NPs as the future focus for active-targeting preclinical XFCT.
Collapse
|
24
|
Abstract
Whole-body imaging of mice is a key source of information for research. Organ segmentation is a prerequisite for quantitative analysis but is a tedious and error-prone task if done manually. Here, we present a deep learning solution called AIMOS that automatically segments major organs (brain, lungs, heart, liver, kidneys, spleen, bladder, stomach, intestine) and the skeleton in less than a second, orders of magnitude faster than prior algorithms. AIMOS matches or exceeds the segmentation quality of state-of-the-art approaches and of human experts. We exemplify direct applicability for biomedical research for localizing cancer metastases. Furthermore, we show that expert annotations are subject to human error and bias. As a consequence, we show that at least two independently created annotations are needed to assess model performance. Importantly, AIMOS addresses the issue of human bias by identifying the regions where humans are most likely to disagree, and thereby localizes and quantifies this uncertainty for improved downstream analysis. In summary, AIMOS is a powerful open-source tool to increase scalability, reduce bias, and foster reproducibility in many areas of biomedical research.
Collapse
|
25
|
In vivo longitudinal and multimodal imaging of hypoxia-inducible factor 1α and angiogenesis in breast cancer. Chin Med J (Engl) 2020; 133:205-211. [PMID: 31904728 PMCID: PMC7028170 DOI: 10.1097/cm9.0000000000000616] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/03/2022] Open
Abstract
Background Angiogenesis and hypoxia-inducible factor 1α (HIF-1α) play major roles in solid tumors. This study aimed to establish a longitudinal and multimodal imaging model for in vivo evaluation of HIF1α and angiogenesis in breast cancer. Methods By transfection of a 5 hypoxia-responsive element (HRE)/green fluorescent protein (GFP) plasmid, the cell line Ca761-hre-gfp was established, which emitted green fluorescence triggered by HIF-1α under hypoxia. The cells were subjected to CoCl2-simulated hypoxia to confirm the imaging strategy. We grew Ca761-hre-gfp cells in the left rear flanks of twelve 615 mice. Experiments were conducted on days 4, 9, 15, and 19. For in vivo analysis, Ca761-hre-gfp subcutaneous allografted tumors were imaged in vivo using contrast-enhanced ultrasound (CEUS) and fluorescence imaging (FLI) during tumor development. The tumor size, CEUS peak intensity, and FLI photons were measured to evaluate tumor growth, angiogenesis, and HIF-1α activity, respectively. After each experiment, three mice were randomly sacrificed and tumor specimens were collected to examine HIF-1α activity and the microvessel density (MVD). Results In vitro, both green fluorescence and HIF-1α expression were detected in Ca761-hre-gfp cells treated with CoCl2, indicating the suitability of the cells to detect HIF-1α activity. In vivo, HIF-1α activity first increased and then decreased, which was significantly correlated with angiogenic changes (r = 0.803, P = 0.005). These changes were confirmed by immunohistochemical staining of HIF-1α and MVD. Conclusions The findings validated the Ca761-hre-gfp murine allograft model for reliable evaluation of HIF-1α activity and angiogenesis longitudinally using both molecular and pre-clinical non-invasive imaging modalities. The cell line may be useful for studies of anti-HIF pathway therapies.
Collapse
|
26
|
In vivo localization of chronically implanted electrodes and optic fibers in mice. Nat Commun 2020; 11:4686. [PMID: 32943633 PMCID: PMC7499215 DOI: 10.1038/s41467-020-18472-y] [Citation(s) in RCA: 11] [Impact Index Per Article: 2.8] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/10/2019] [Accepted: 08/24/2020] [Indexed: 12/20/2022] Open
Abstract
Electrophysiology provides a direct readout of neuronal activity at a temporal precision only limited by the sampling rate. However, interrogating deep brain structures, implanting multiple targets or aiming at unusual angles still poses significant challenges for operators, and errors are only discovered by post-hoc histological reconstruction. Here, we propose a method combining the high-resolution information about bone landmarks provided by micro-CT scanning with the soft tissue contrast of the MRI, which allowed us to precisely localize electrodes and optic fibers in mice in vivo. This enables arbitrating the success of implantation directly after surgery with a precision comparable to gold standard histology. Adjustment of the recording depth with micro-drives or early termination of unsuccessful experiments saves many working hours, and fast 3-dimensional feedback helps surgeons avoid systematic errors. Increased aiming precision enables more precise targeting of small or deep brain nuclei and multiple targeting of specific cortical or hippocampal layers.
Collapse
|
27
|
Development of an embedded multimodality imaging platform for onco-pharmacology using a smart anticancer prodrug as an example. Sci Rep 2020; 10:2661. [PMID: 32060400 PMCID: PMC7021674 DOI: 10.1038/s41598-020-59561-8] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/12/2019] [Accepted: 01/28/2020] [Indexed: 11/08/2022] Open
Abstract
Increasingly, in vivo imaging holds a strategic position in bio-pharmaceutical innovation. We will present the implementation of an integrated multimodal imaging setup enabling the assessment of multiple, complementary parameters. The system allows the fusion of information provided by: Near infrared fluorescent biomarkers, bioluminescence (for tumor proliferation status), Photoacoustic and Ultrasound imaging. We will study representative applications to the development of a smart prodrug, delivering a highly cytotoxic chemotherapeutic agent to cancer tumors. The results realized the ability of this embedded, multimodality imaging platform to firstly detect bioluminescent and fluorescent signals, and secondly, record ultrasound and photoacoustic data from the same animal. This study demonstrated that the prodrug was effective in three different models of hypoxia in human cancers compared to the parental cytotoxic agent and the vehicle groups. Monitoring by photoacoustic imaging during the treatments revealed that the prodrug exhibits an intrinsic capability to prevent the progression of tumor hypoxia. It is essential for onco-pharmacology studies to precisely document the hypoxic status of tumors both before and during the time course of treatments. This approach opens new perspectives for exploitation of preclinical mouse models of cancer, especially when considering associations between hypoxia, neoangiogenesis and antitumor activity.
Collapse
|
28
|
Prediction of major torso organs in low-contrast micro-CT images of mice using a two-stage deeply supervised fully convolutional network. Phys Med Biol 2019; 64:245014. [PMID: 31747654 DOI: 10.1088/1361-6560/ab59a4] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/29/2022]
Abstract
Delineation of major torso organs is a key step of mouse micro-CT image analysis. This task is challenging due to low soft tissue contrast and high image noise, therefore anatomical prior knowledge is needed for accurate prediction of organ regions. In this work, we develop a deeply supervised fully convolutional network which uses the organ anatomy prior learned from independently acquired contrast-enhanced micro-CT images to assist the segmentation of non-enhanced images. The network is designed with a two-stage workflow which firstly predicts the rough regions of multiple organs and then refines the accuracy of each organ in local regions. The network is trained and evaluated with 40 mouse micro-CT images. The volumetric prediction accuracy (Dice score) varies from 0.57 for the spleen to 0.95 for the heart. Compared to a conventional atlas registration method, our method dramatically improves the Dice of the abdominal organs by 18%-26%. Moreover, the incorporation of anatomical prior leads to more accurate results for small-sized low-contrast organs (e.g. the spleen and kidneys). We also find that the localized stage of the network has better accuracy than the global stage, indicating that localized single organ prediction is more accurate than global multiple organ prediction. With this work, the accuracy and efficiency of mouse micro-CT image analysis are greatly improved and the need for using contrast agent and high x-ray dose is potentially reduced.
Collapse
|
29
|
Magnetic Resonance Imaging for Translational Research in Oncology. J Clin Med 2019; 8:jcm8111883. [PMID: 31698697 PMCID: PMC6912299 DOI: 10.3390/jcm8111883] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/01/2019] [Revised: 10/28/2019] [Accepted: 10/29/2019] [Indexed: 12/19/2022] Open
Abstract
The translation of results from the preclinical to the clinical setting is often anything other than straightforward. Indeed, ideas and even very intriguing results obtained at all levels of preclinical research, i.e., in vitro, on animal models, or even in clinical trials, often require much effort to validate, and sometimes, even useful data are lost or are demonstrated to be inapplicable in the clinic. In vivo, small-animal, preclinical imaging uses almost the same technologies in terms of hardware and software settings as for human patients, and hence, might result in a more rapid translation. In this perspective, magnetic resonance imaging might be the most translatable technique, since only in rare cases does it require the use of contrast agents, and when not, sequences developed in the lab can be readily applied to patients, thanks to their non-invasiveness. The wide range of sequences can give much useful information on the anatomy and pathophysiology of oncologic lesions in different body districts. This review aims to underline the versatility of this imaging technique and its various approaches, reporting the latest preclinical studies on thyroid, breast, and prostate cancers, both on small laboratory animals and on human patients, according to our previous and ongoing research lines.
Collapse
|
30
|
In vivo contrast-enhanced microCT for the monitoring of mouse thoracic, lumbar, and coccygeal intervertebral discs. JOR Spine 2019; 2:e1058. [PMID: 31463468 PMCID: PMC6686789 DOI: 10.1002/jsp2.1058] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 04/15/2019] [Revised: 05/23/2019] [Accepted: 05/23/2019] [Indexed: 12/12/2022] Open
Abstract
Mouse models are often used for studies of intervertebral disc (IVD) homeostasis and degeneration, yet the relatively small size of the IVD poses challenges for noninvasive, longitudinal imaging modalities. The recently developed contrast-enhanced microCT (CEμCT) using Ioversol has been successful in detecting degenerative changes in the murine IVD ex vivo at the micrometer scale. Further leveraging the superior biocompatibility of Ioversol as a contrast agent, we demonstrate the in vivo use of this CEμCT technique to examine IVDs at multiple spinal sites. Ioversol was administered via tail vein injection (TVI) in growing and adult male FVB/NJ mice (n = 5 /group). The animals were anesthetized and underwent in vivo micro-computed tomographic (microCT) at the coccygeal (CC5/CC6), lumbar (L5/6), and thoracic (T12/T13) IVDs. TVI of Ioversol was well-tolerated by all animals. As Ioversol filtered through the kidneys and accumulated in the bladder, the attenuations of the mouse bladder and kidneys increased due to the high molecular weight of Ioversol, confirming that the Ioversol is biological available. Average IVD attenuations increased 3%-15% following TVI (ANOVA; P < .01). The presence of Ioversol in the IVD combined with high-resolution microCT allow for nondestructive visualization of structural features of the IVD. These results demonstrate CEμCT with Ioversol as a viable strategy for the in vivo monitoring of multiple mouse IVDs during degeneration, disease, and injury.
Collapse
|
31
|
Ocular Biodistribution Studies using Molecular Imaging. Pharmaceutics 2019; 11:pharmaceutics11050237. [PMID: 31100961 PMCID: PMC6572242 DOI: 10.3390/pharmaceutics11050237] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/14/2019] [Revised: 05/05/2019] [Accepted: 05/07/2019] [Indexed: 02/07/2023] Open
Abstract
Classical methodologies used in ocular pharmacokinetics studies have difficulties to obtain information about topical and intraocular distribution and clearance of drugs and formulations. This is associated with multiple factors related to ophthalmic physiology, as well as the complexity and invasiveness intrinsic to the sampling. Molecular imaging is a new diagnostic discipline for in vivo imaging, which is emerging and spreading rapidly. Recent developments in molecular imaging techniques, such as positron emission tomography (PET), single-photon emission computed tomography (SPECT) and magnetic resonance imaging (MRI), allow obtaining reliable pharmacokinetic data, which can be translated into improving the permanence of the ophthalmic drugs in its action site, leading to dosage optimisation. They can be used to study either topical or intraocular administration. With these techniques it is possible to obtain real-time visualisation, localisation, characterisation and quantification of the compounds after their administration, all in a reliable, safe and non-invasive way. None of these novel techniques presents simultaneously high sensitivity and specificity, but it is possible to study biological procedures with the information provided when the techniques are combined. With the results obtained, it is possible to assume that molecular imaging techniques are postulated as a resource with great potential for the research and development of new drugs and ophthalmic delivery systems.
Collapse
|
32
|
Three-Dimensional Ultrasound Versus Computerized Tomography in Fat Graft Volumetric Analysis. Ann Plast Surg 2019; 80:293-296. [PMID: 28678028 DOI: 10.1097/sap.0000000000001183] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/26/2022]
Abstract
Studies evaluating fat grafting in mice have frequently used micro-computed tomography (micro-CT) as an accurate radiographic tool to measure longitudinal volume retention without killing the animal. Over the past decade, however, microultrasonography has emerged as an equally powerful preclinical imaging tool. Given their respective strengths in 3-dimensional reconstruction, there is no study to our knowledge that directly compares micro-CT with microultrasound in volumetric analysis. In this study, we compared the performance of micro-CT with microultrasound in the evaluation of adipose tissue graft volume in a murine model. Fifteen immunodeficient mice were given 200 μL of adipose tissue grafts. In vivo volumetric analysis of the grafts by micro-CT and microultrasound was conducted at discrete time points up to postoperative day 105. Three mice were killed at multiple time points, and explanted grafts were reimaged by CT and ultrasound, as mentioned previously. Analysis revealed that in vivo graft volumes measured by micro-CT do not differ significantly from those of microultrasound. Furthermore, both micro-CT and microultrasound were capable of accurately measuring fat grafts as in vivo volumes closely correlated with explanted volumes. Finally, ultrasound was found to yield improved soft tissue contrast compared with micro-CT. Therefore, either modality may be used, depending on experimental needs.
Collapse
|
33
|
Photoacoustic imaging in the second near-infrared window: a review. JOURNAL OF BIOMEDICAL OPTICS 2019; 24:1-20. [PMID: 30968648 PMCID: PMC6990072 DOI: 10.1117/1.jbo.24.4.040901] [Citation(s) in RCA: 96] [Impact Index Per Article: 19.2] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 10/02/2018] [Accepted: 03/18/2019] [Indexed: 05/04/2023]
Abstract
Photoacoustic (PA) imaging is an emerging medical imaging modality that combines optical excitation and ultrasound detection. Because ultrasound scatters much less than light in biological tissues, PA generates high-resolution images at centimeters depth. In recent years, wavelengths in the second near-infrared (NIR-II) window (1000 to 1700 nm) have been increasingly explored due to its potential for preclinical and clinical applications. In contrast to the conventional PA imaging in the visible (400 to 700 nm) and the first NIR-I (700 to 1000 nm) window, PA imaging in the NIR-II window offers numerous advantages, including high spatial resolution, deeper penetration depth, reduced optical absorption, and tissue scattering. Moreover, the second window allows a fivefold higher light excitation energy density compared to the visible window for enhancing the imaging depth significantly. We highlight the importance of the second window for PA imaging and discuss the various NIR-II PA imaging systems and contrast agents with strong absorption in the NIR-II spectral region. Numerous applications of NIR-II PA imaging, including whole-body animal imaging and human imaging, are also discussed.
Collapse
|
34
|
Reproducibility and Comparability of Preclinical PET Imaging Data: A Multicenter Small-Animal PET Study. J Nucl Med 2019; 60:1483-1491. [PMID: 30850496 DOI: 10.2967/jnumed.118.221994] [Citation(s) in RCA: 14] [Impact Index Per Article: 2.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/25/2018] [Accepted: 02/25/2019] [Indexed: 01/09/2023] Open
Abstract
The standardization of preclinical imaging is a key factor to ensure the reliability, reproducibility, validity, and translatability of preclinical data. Preclinical standardization has been slowly progressing in recent years and has mainly been performed within a single institution, whereas little has been done in regards to multicenter standardization between facilities. This study aimed to investigate the comparability among preclinical imaging facilities in terms of PET data acquisition and analysis. In the first step, basic PET scans were obtained in 4 different preclinical imaging facilities to compare their standard imaging protocol for 18F-FDG. In the second step, the influence of the personnel performing the experiments and the experimental equipment used in the experiment were compared. In the third step, the influence of the image analysis on the reproducibility and comparability of the acquired data was determined. Distinct differences in the uptake behavior of the 4 standard imaging protocols were determined for the investigated organs (brain, left ventricle, liver, and muscle) due to different animal handling procedures before and during the scans (e.g., fasting vs. nonfasting, glucose levels, temperature regulation vs. constant temperature warming). Significant differences in the uptake behavior in the brain were detected when the same imaging protocol was used but executed by different personnel and using different experimental animal handling equipment. An influence of the person analyzing the data was detected for most of the organs, when the volumes of interest were manually drawn by the investigators. Coregistration of the PET to an MR image and drawing the volume of interest based on anatomic information yielded reproducible results among investigators. It has been demonstrated that there is a huge demand for standardization among multiple institutions.
Collapse
|
35
|
Automatic deformable PET/MRI registration for preclinical studies based on B-splines and non-linear intensity transformation. Med Biol Eng Comput 2018; 56:1531-1539. [DOI: 10.1007/s11517-018-1797-0] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/15/2017] [Accepted: 01/28/2018] [Indexed: 11/27/2022]
|
36
|
High-spatial-resolution x-ray fluorescence tomography with spectrally matched nanoparticles. Phys Med Biol 2018; 63:164001. [PMID: 30033936 DOI: 10.1088/1361-6560/aad51e] [Citation(s) in RCA: 24] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/12/2022]
Abstract
Present macroscopic biomedical imaging methods provide either morphology with high spatial resolution (e.g. CT) or functional/molecular information with lower resolution (e.g. PET). X-ray fluorescence (XRF) from targeted nanoparticles allows molecular or functional imaging but sensitivity has so far been insufficient resulting in low spatial resolution, despite long exposure times and high dose. In the present paper, we show that laboratory XRF tomography with metal-core nanoparticles (NPs) provides a path to functional/molecular biomedical imaging with ~100 µm resolution in living rodents. The high sensitivity and resolution rely on the combination of a high-brightness liquid-metal-jet x-ray source, pencil-beam optics, photon-counting energy-dispersive detection, and spectrally matched NPs. The method is demonstrated on mice for 3D tumor imaging via passive targeting of in-house-fabricated molybdenum NPs. Exposure times, nanoparticle dose, and radiation dose agree well with in vivo imaging.
Collapse
|
37
|
|
38
|
Evaluation of Hamamatsu H13974 Large Sensitive Area Flat Panel PMT Array for Use in Small Animal Imaging and Scintimammography. IEEE TRANSACTIONS ON RADIATION AND PLASMA MEDICAL SCIENCES 2018. [DOI: 10.1109/trpms.2018.2797323] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/06/2022]
|
39
|
ESTRO ACROP: Technology for precision small animal radiotherapy research: Optimal use and challenges. Radiother Oncol 2018; 126:471-478. [PMID: 29269093 DOI: 10.1016/j.radonc.2017.11.016] [Citation(s) in RCA: 73] [Impact Index Per Article: 12.2] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/18/2017] [Accepted: 11/21/2017] [Indexed: 11/30/2022]
Abstract
Many radiotherapy research centers have recently installed novel research platforms enabling the investigation of the radiation response of tumors and normal tissues in small animal models, possibly in combination with other treatment modalities. Many more research institutes are expected to follow in the coming years. These novel platforms are capable of mimicking human radiotherapy more closely than older technology. To facilitate the optimal use of these novel integrated precision irradiators and various small animal imaging devices, and to maximize the impact of the associated research, the ESTRO committee on coordinating guidelines ACROP (Advisory Committee in Radiation Oncology Practice) has commissioned a report to review the state of the art of the technology used in this new field of research, and to issue recommendations. This report discusses the combination of precision irradiation systems, small animal imaging (CT, MRI, PET, SPECT, bioluminescence) systems, image registration, treatment planning, and data processing. It also provides guidelines for reporting on studies.
Collapse
|
40
|
Incorporation of an ultrasound and model guided permissible region improves quantitative source recovery in bioluminescence tomography. BIOMEDICAL OPTICS EXPRESS 2018; 9. [PMID: 29541527 PMCID: PMC5846537 DOI: 10.1364/boe.9.001360] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/13/2023]
Abstract
Bioluminescence imaging has shown great potential for studying and monitoring disease progression in small animal pre-clinical imaging. However, absolute bioluminescence source recovery through tomographic multi-wavelength measurements is often hindered through the lack of quantitative accuracy and suffers from both poor localisation and quantitative recovery. In this work a method to incorporate a permissible region strategy through not only a priori location (permissible region) but also based on a model of light propagation and hence light sensitivity is developed and tested using both simulations and experimental data. Reconstructions on two different numerical models (a simple slab, and the digital version of a heterogeneous mouse) show an improvement of localisation and recovery of intensity (around 25% for the slab model and around 10% for the digital mouse model). This strategy is also used with experimental data from a phantom gel, which demonstrated an improved recovered tomographic image.
Collapse
|
41
|
Acoustic Properties of Small Animal Soft Tissue in the Frequency Range 12-32 MHz. ULTRASOUND IN MEDICINE & BIOLOGY 2018; 44:702-713. [PMID: 29277451 DOI: 10.1016/j.ultrasmedbio.2017.11.003] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 07/27/2017] [Revised: 10/16/2017] [Accepted: 11/07/2017] [Indexed: 06/07/2023]
Abstract
Quality assurance phantoms are made of tissue-mimicking materials (TMMs) the acoustic properties of which mimic those of soft tissue. However, the acoustic properties of many soft tissue types have not been measured at ultrasonic frequencies >9 MHz. With the increasing use of high-frequency ultrasound for both clinical and pre-clinical applications, it is of increasing interest to ensure that TMMs accurately reflect the acoustic properties of soft tissue at these higher frequencies. In this study, the acoustic properties of ex vivo brain, liver and kidney samples from 50 mice were assessed in the frequency range 12-32 MHz. Measurements were performed within 6 min of euthanasia in a phosphate-buffered saline solution maintained at 37.2 ± 0.2 °C. The measured mean values for the speed of sound for all organs were found to be higher than the International Electrotechnical Commission guideline recommended value for TMMs. The attenuation coefficients measured for brain, liver and kidney samples were compared with the results of previous studies at lower frequencies. Only the measured kidney attenuation coefficient was found to be in good agreement with the International Electrotechnical Commission guideline. The information provided in this study can be used as a baseline on which to manufacture a TMM suitable for high-frequency applications.
Collapse
|
42
|
Characterization of "γ-Eye": a Low-Cost Benchtop Mouse-Sized Gamma Camera for Dynamic and Static Imaging Studies. Mol Imaging Biol 2018; 19:398-407. [PMID: 27730469 DOI: 10.1007/s11307-016-1011-4] [Citation(s) in RCA: 14] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/20/2022]
Abstract
PURPOSE Several preclinical imaging systems are commercially available, but their purchase and maintenance costs make them unaffordable for the majority of small- and medium-sized groups. Taking into account the needs of average users, we developed "γ-eye", a mouse-sized, benchtop γ-camera suitable for in vivo scintigraphic imaging. PROCEDURES The γ-eye is based on two position-sensitive photomultiplier tubes, coupled to a CsI(Na) pixelated scintillator and a low-energy lead collimator with parallel hexagonal holes. RESULTS The spatial resolution of the system is 2 mm at 0 mm. The energy resolution is 26 % at 140 keV and the maximum recorded sensitivity 210 cps/MBq. The system was evaluated in a proof-of-concept animal study, using three different clinical Tc-99m-labeled radiopharmaceuticals. Phantom and animal studies demonstrate its ability to provide semiquantitative results even for short scans. CONCLUSIONS Systems' performance, dimensions, and cost make γ-eye a unique solution for efficient whole-body mouse nuclear imaging.
Collapse
|
43
|
Abstract
In recent decades, imaging devices have become indispensable tools in the basic sciences, in preclinical research and in modern drug development. The rapidly evolving high-resolution in vivo imaging technologies provide a unique opportunity for studying biological processes of living organisms in real time on a molecular level. State of the art small-animal imaging modalities provide non-invasive images rich in quantitative anatomical and functional information, which renders longitudinal studies possible allowing precise monitoring of disease progression and response to therapy in models of different diseases. The number of animals in a scientific investigation can be substantially reduced using imaging techniques, which is in full compliance with the ethical endeavours for the 3R (reduction, refinement, replacement) policies formulated by Russell and Burch; furthermore, biological variability can be alleviated, as each animal serves as its own control. The most suitable and commonly used imaging modalities for in vivo small-animal imaging are optical imaging (OI), ultrasonography (US), computed tomography (CT), magnetic resonance imaging (MRI), and finally the methods of nuclear medicine: positron emission tomography (PET) and single photon emission computed tomography (SPECT).
Collapse
|
44
|
188Re image performance assessment using small animal multi-pinhole SPECT/PET/CT system. Phys Med 2017; 33:26-37. [DOI: 10.1016/j.ejmp.2016.11.105] [Citation(s) in RCA: 10] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 08/17/2016] [Revised: 10/10/2016] [Accepted: 11/14/2016] [Indexed: 02/08/2023] Open
|
45
|
High-resolution short-exposure small-animal laboratory x-ray phase-contrast tomography. Sci Rep 2016; 6:39074. [PMID: 27958376 PMCID: PMC5153650 DOI: 10.1038/srep39074] [Citation(s) in RCA: 28] [Impact Index Per Article: 3.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/12/2016] [Accepted: 11/17/2016] [Indexed: 01/06/2023] Open
Abstract
X-ray computed tomography of small animals and their organs is an essential tool in basic and preclinical biomedical research. In both phase-contrast and absorption tomography high spatial resolution and short exposure times are of key importance. However, the observable spatial resolutions and achievable exposure times are presently limited by system parameters rather than more fundamental constraints like, e.g., dose. Here we demonstrate laboratory tomography with few-ten μm spatial resolution and few-minute exposure time at an acceptable dose for small-animal imaging, both with absorption contrast and phase contrast. The method relies on a magnifying imaging scheme in combination with a high-power small-spot liquid-metal-jet electron-impact source. The tomographic imaging is demonstrated on intact mouse, phantoms and excised lungs, both healthy and with pulmonary emphysema.
Collapse
|
46
|
Beauty is more than skin deep: a non‐invasive protocol for
in vivo
anatomical study using micro‐CT. Methods Ecol Evol 2016. [DOI: 10.1111/2041-210x.12661] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/18/2023]
|
47
|
In vivo fluorescence imaging to assess early therapeutic response to tumor progression in a xenograft cancer model. BIOTECHNOL BIOPROC E 2016. [DOI: 10.1007/s12257-016-0251-0] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/21/2022]
|
48
|
Real-Time Microfluidic Blood-Counting System for PET and SPECT Preclinical Pharmacokinetic Studies. J Nucl Med 2016; 57:1460-6. [DOI: 10.2967/jnumed.115.162768] [Citation(s) in RCA: 15] [Impact Index Per Article: 1.9] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/26/2015] [Accepted: 03/29/2016] [Indexed: 02/03/2023] Open
|
49
|
Fourier Analysis of Noise Characteristics in Cone-Beam Microtomography Laboratory Scanners. IEEE Trans Biomed Eng 2016; 64:173-183. [PMID: 27093307 DOI: 10.1109/tbme.2016.2552496] [Citation(s) in RCA: 7] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/10/2022]
Abstract
GOAL We investigate the signal and noise performance of an x-ray microtomography system that incorporates a complementary metal-oxide-semiconductor flat-panel detector as a projection image receptor. METHODS Signal and noise performance is analyzed in the Fourier domain using modulation-transfer function (MTF), noise-power spectrum (NPS), and noise-equivalent number of quanta (NEQ) with respect to magnification and different convolution kernels for image reconstruction. RESULTS Higher magnification provides lower NPS, and thus, higher NEQ performance in the transaxial planes from microtomography. A window function capable of smoothing the ramp filter edge to below one-half of the Nyquist limit results in better performance in terms of NPS and NEQ. The characteristics of convolution kernels do not affect signal and noise performance in longitudinal planes; hence, MTF performance mainly dominates the NEQ performance. The signal and noise performances investigated in this study are demonstrated with images obtained from the contrast phantom and postmortem mouse. CONCLUSION The results of our study could be helpful in developing x-ray microtomography systems based on flat-panel detectors.
Collapse
|
50
|
High Resolution Ultrasound and Photoacoustic Imaging of Orthotopic Lung Cancer in Mice: New Perspectives for Onco-Pharmacology. PLoS One 2016; 11:e0153532. [PMID: 27070548 PMCID: PMC4829195 DOI: 10.1371/journal.pone.0153532] [Citation(s) in RCA: 27] [Impact Index Per Article: 3.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/02/2016] [Accepted: 03/30/2016] [Indexed: 11/18/2022] Open
Abstract
Objectives We have developed a relevant preclinical model associated with a specific imaging protocol dedicated to onco-pharmacology studies in mice. Materials and Methods We optimized both the animal model and an ultrasound imaging procedure to follow up longitudinally the lung tumor growth in mice. Moreover we proposed to measure by photoacoustic imaging the intratumoral hypoxia, which is a crucial parameter responsible for resistance to therapies. Finally, we compared ultrasound data to x-ray micro computed tomography and volumetric measurements to validate the relevance of this approach on the NCI-H460 human orthotopic lung tumor. Results This study demonstrates the ability of ultrasound imaging to detect and monitor the in vivo orthotopic lung tumor growth by high resolution ultrasound imaging. This approach enabled us to characterize key biological parameters such as oxygenation, perfusion status and vascularization of tumors. Conclusion Such an experimental approach has never been reported previously and it would provide a nonradiative tool for assessment of anticancer therapeutic efficacy in mice. Considering the absence of ultrasound propagation through the lung parenchyma, this strategy requires the implantation of tumors strictly located in the superficial posterior part of the lung.
Collapse
|