1
|
Xi H, Ross KE, Hinds J, Molino PJ, Whiley H. Efficacy of chlorine-based disinfectants to control Legionella within premise plumbing systems. WATER RESEARCH 2024; 259:121794. [PMID: 38824796 DOI: 10.1016/j.watres.2024.121794] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 01/19/2024] [Revised: 05/14/2024] [Accepted: 05/16/2024] [Indexed: 06/04/2024]
Abstract
Legionella is an opportunistic waterborne pathogen that causes Legionnaires' disease. It poses a significant public health risk, especially to vulnerable populations in health care facilities. It is ubiquitous in manufactured water systems and is transmitted via inhalation or aspiration of aerosols/water droplets generated from water fixtures (e.g., showers and hand basins). As such, the effective management of premise plumbing systems (building water systems) in health care facilities is essential for reducing the risk of Legionnaires' disease. Chemical disinfection is a commonly used control method and chlorine-based disinfectants, including chlorine, chloramine, and chlorine dioxide, have been used for over a century. However, the effectiveness of these disinfectants in premise plumbing systems is affected by various interconnected factors that can make it challenging to maintain effective disinfection. This systematic literature review identifies all studies that have examined the factors impacting the efficacy and decay of chlorine-based disinfectant within premise plumbing systems. A total of 117 field and laboratory-based studies were identified and included in this review. A total of 20 studies directly compared the effectiveness of the different chlorine-based disinfectants. The findings from these studies ranked the typical effectiveness as follows: chloramine > chlorine dioxide > chlorine. A total of 26 factors were identified across 117 studies as influencing the efficacy and decay of disinfectants in premise plumbing systems. These factors were sorted into categories of operational factors that are changed by the operation of water devices and fixtures (such as stagnation, temperature, water velocity), evolving factors which are changed in-directly (such as disinfectant concentration, Legionella disinfectant resistance, Legionella growth, season, biofilm and microbe, protozoa, nitrification, total organic carbon(TOC), pH, dissolved oxygen(DO), hardness, ammonia, and sediment and pipe deposit) and stable factors that are not often changed(such as disinfectant type, pipe material, pipe size, pipe age, water recirculating, softener, corrosion inhibitor, automatic sensor tap, building floor, and construction activity). A factor-effect map of each of these factors and whether they have a positive or negative association with disinfection efficacy against Legionella in premise plumbing systems is presented. It was also found that evaluating the effectiveness of chlorine disinfection as a water risk management strategy is further complicated by varying disinfection resistance of Legionella species and the form of Legionella (culturable/viable but non culturable, free living/biofilm associated, intracellular replication within amoeba hosts). Future research is needed that utilises sensors and other approaches to measure these key factors (such as pH, temperature, stagnation, water age and disinfection residual) in real time throughout premise plumbing systems. This information will support the development of improved models to predict disinfection within premise plumbing systems. The findings from this study will inform the use of chlorine-based disinfection within premise plumbing systems to reduce the risk of Legionnaires disease.
Collapse
Affiliation(s)
- Hao Xi
- College of Science and Engineering, Flinders University, Bedford Park, SA, Australia; Enware Pty Ltd, Caringbah, NSW, Australia.
| | - Kirstin E Ross
- College of Science and Engineering, Flinders University, Bedford Park, SA, Australia
| | - Jason Hinds
- ARC Training Centre for Biofilm Research and Innovation, Flinders University, Bedford Park, SA, Australia; Enware Pty Ltd, Caringbah, NSW, Australia
| | | | - Harriet Whiley
- College of Science and Engineering, Flinders University, Bedford Park, SA, Australia; ARC Training Centre for Biofilm Research and Innovation, Flinders University, Bedford Park, SA, Australia
| |
Collapse
|
2
|
LeChevallier MW, Prosser T, Stevens M. Opportunistic Pathogens in Drinking Water Distribution Systems-A Review. Microorganisms 2024; 12:916. [PMID: 38792751 PMCID: PMC11124194 DOI: 10.3390/microorganisms12050916] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/01/2024] [Revised: 04/24/2024] [Accepted: 04/25/2024] [Indexed: 05/26/2024] Open
Abstract
In contrast to "frank" pathogens, like Salmonella entrocolitica, Shigella dysenteriae, and Vibrio cholerae, that always have a probability of disease, "opportunistic" pathogens are organisms that cause an infectious disease in a host with a weakened immune system and rarely in a healthy host. Historically, drinking water treatment has focused on control of frank pathogens, particularly those from human or animal sources (like Giardia lamblia, Cryptosporidium parvum, or Hepatitis A virus), but in recent years outbreaks from drinking water have increasingly been due to opportunistic pathogens. Characteristics of opportunistic pathogens that make them problematic for water treatment include: (1) they are normally present in aquatic environments, (2) they grow in biofilms that protect the bacteria from disinfectants, and (3) under appropriate conditions in drinking water systems (e.g., warm water, stagnation, low disinfectant levels, etc.), these bacteria can amplify to levels that can pose a public health risk. The three most common opportunistic pathogens in drinking water systems are Legionella pneumophila, Mycobacterium avium, and Pseudomonas aeruginosa. This report focuses on these organisms to provide information on their public health risk, occurrence in drinking water systems, susceptibility to various disinfectants, and other operational practices (like flushing and cleaning of pipes and storage tanks). In addition, information is provided on a group of nine other opportunistic pathogens that are less commonly found in drinking water systems, including Aeromonas hydrophila, Klebsiella pneumoniae, Serratia marcescens, Burkholderia pseudomallei, Acinetobacter baumannii, Stenotrophomonas maltophilia, Arcobacter butzleri, and several free-living amoebae including Naegleria fowleri and species of Acanthamoeba. The public health risk for these microbes in drinking water is still unclear, but in most cases, efforts to manage Legionella, mycobacteria, and Pseudomonas risks will also be effective for these other opportunistic pathogens. The approach to managing opportunistic pathogens in drinking water supplies focuses on controlling the growth of these organisms. Many of these microbes are normal inhabitants in biofilms in water, so the attention is less on eliminating these organisms from entering the system and more on managing their occurrence and concentrations in the pipe network. With anticipated warming trends associated with climate change, the factors that drive the growth of opportunistic pathogens in drinking water systems will likely increase. It is important, therefore, to evaluate treatment barriers and management activities for control of opportunistic pathogen risks. Controls for primary treatment, particularly for turbidity management and disinfection, should be reviewed to ensure adequacy for opportunistic pathogen control. However, the major focus for the utility's opportunistic pathogen risk reduction plan is the management of biological activity and biofilms in the distribution system. Factors that influence the growth of microbes (primarily in biofilms) in the distribution system include, temperature, disinfectant type and concentration, nutrient levels (measured as AOC or BDOC), stagnation, flushing of pipes and cleaning of storage tank sediments, and corrosion control. Pressure management and distribution system integrity are also important to the microbial quality of water but are related more to the intrusion of contaminants into the distribution system rather than directly related to microbial growth. Summarizing the identified risk from drinking water, the availability and quality of disinfection data for treatment, and guidelines or standards for control showed that adequate information is best available for management of L. pneumophila. For L. pneumophila, the risk for this organism has been clearly established from drinking water, cases have increased worldwide, and it is one of the most identified causes of drinking water outbreaks. Water management best practices (e.g., maintenance of a disinfectant residual throughout the distribution system, flushing and cleaning of sediments in pipelines and storage tanks, among others) have been shown to be effective for control of L. pneumophila in water supplies. In addition, there are well documented management guidelines available for the control of the organism in drinking water distribution systems. By comparison, management of risks for Mycobacteria from water are less clear than for L. pneumophila. Treatment of M. avium is difficult due to its resistance to disinfection, the tendency to form clumps, and attachment to surfaces in biofilms. Additionally, there are no guidelines for management of M. avium in drinking water, and one risk assessment study suggested a low risk of infection. The role of tap water in the transmission of the other opportunistic pathogens is less clear and, in many cases, actions to manage L. pneumophila (e.g., maintenance of a disinfectant residual, flushing, cleaning of storage tanks, etc.) will also be beneficial in helping to manage these organisms as well.
Collapse
Affiliation(s)
| | - Toby Prosser
- Melbourne Water, Melbourne, VIC 3001, Australia; (T.P.); (M.S.)
| | - Melita Stevens
- Melbourne Water, Melbourne, VIC 3001, Australia; (T.P.); (M.S.)
| |
Collapse
|
3
|
Zhang J, Li T, Tao S, Shen M. Microplastic pollution interaction with disinfectant resistance genes: research progress, environmental impacts, and potential threats. ENVIRONMENTAL SCIENCE AND POLLUTION RESEARCH INTERNATIONAL 2024; 31:16241-16255. [PMID: 38340302 DOI: 10.1007/s11356-024-32225-0] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 10/31/2023] [Accepted: 01/23/2024] [Indexed: 02/12/2024]
Abstract
The consumption of disposable plastic products and disinfectants has surged during the global COVID-19 pandemic, as they play a vital role in effectively preventing and controlling the spread of the virus. However, microplastic pollution and the excessive or improper use of disinfectants contribute to the increased environmental tolerance of microorganisms. Microplastics play a crucial role as vectors for microorganisms and plankton, facilitating energy transfer and horizontal gene exchange. The increase in the use of disinfectants has become a driving force for the growth of disinfectant resistant bacteria (DRB). A large number of microorganisms can have intense gene exchange, such as plasmid loss and capture, phage transduction, and cell fusion. The reproduction and diffusion rate of DRB in the environment is significantly higher than that of ordinary microorganisms, which will greatly increase the environmental tolerance of DRB. Unfortunately, there is still a huge knowledge gap in the interaction between microplastics and disinfectant resistance genes (DRGs). Accordingly, it is critical to comprehensively summarize the formation and transmission routes of DRGs on microplastics to address the problem. This paper systematically analyzed the process and mechanisms of DRGs formed by microbes. The interaction between microplastics and DRGs and the contribution of microplastic on the diffusion and spread of DRGs were expounded. The potential threats to the ecological environment and human health were also discussed. Additionally, some challenges and future priorities were also proposed with a view to providing useful basis for further research.
Collapse
Affiliation(s)
- Jiahao Zhang
- School of Energy and Environment, Anhui University of Technology, Maanshan, Anhui, 243002, People's Republic of China
| | - Tianhao Li
- School of Energy and Environment, Anhui University of Technology, Maanshan, Anhui, 243002, People's Republic of China
| | - Shiyu Tao
- School of Energy and Environment, Anhui University of Technology, Maanshan, Anhui, 243002, People's Republic of China
| | - Maocai Shen
- School of Energy and Environment, Anhui University of Technology, Maanshan, Anhui, 243002, People's Republic of China.
| |
Collapse
|
4
|
Ren A, Yao M, Fang J, Dai Z, Li X, van der Meer W, Medema G, Rose JB, Liu G. Bacterial communities of planktonic bacteria and mature biofilm in service lines and premise plumbing of a Megacity: Composition, Diversity, and influencing factors. ENVIRONMENT INTERNATIONAL 2024; 185:108538. [PMID: 38422875 DOI: 10.1016/j.envint.2024.108538] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 12/28/2023] [Revised: 02/14/2024] [Accepted: 02/26/2024] [Indexed: 03/02/2024]
Abstract
Although simulated studies have provided valuable knowledge regarding the communities of planktonic bacteria and biofilms, the lack of systematic field studies have hampered the understanding of microbiology in real-world service lines and premise plumbing. In this study, the bacterial communities of water and biofilm were explored, with a special focus on the lifetime development of biofilm communities and their key influencing factors. The 16S rRNA gene sequencing results showed that both the planktonic bacteria and biofilm were dominated by Proteobacteria. Among the 15,084 observed amplicon sequence variants (ASVs), the 33 core ASVs covered 72.8 %, while the 12 shared core ASVs accounted for 62.2 % of the total sequences. Remarkably, it was found that the species richness and diversity of biofilm communities correlated with pipe age. The relative abundance of ASV2 (f_Sphingomonadaceae) was lower for pipe ages 40-50 years (7.9 %) than for pipe ages 10-20 years (59.3 %), while the relative abundance of ASV10 (f_Hyphomonadaceae) was higher for pipe ages 40-50 years (19.5 %) than its presence at pipe ages 20-30 years (1.9 %). The community of the premise plumbing biofilm had significantly higher species richness and diversity than that of the service line, while the steel-plastics composite pipe interior lined with polyethylene (S-PE) harbored significantly more diverse biofilm than the galvanized steel pipes (S-Zn). Interestingly, S-PE was enriched with ASV27 (g_Mycobacterium), while S-Zn pipes were enriched with ASV13 (g_Pseudomonas). Moreover, the network analysis showed that five rare ASVs, not core ASVs, were keystone members in biofilm communities, indicating the importance of rare members in the function and stability of biofilm communities. This manuscript provides novel insights into real-world service lines and premise plumbing microbiology, regarding lifetime dynamics (pipe age 10-50 years), and the influences of pipe types (premise plumbing vs. service line) and pipe materials (S-Zn vs. S-PE).
Collapse
Affiliation(s)
- Anran Ren
- Key Laboratory of Drinking Water Science and Technology, Research Centre for Eco-Environmental Sciences, Chinese Academy of Sciences, Beijing 100085, China; Sanitary Engineering, Department of Water Management, Faculty of Civil Engineering and Geosciences, Delft University of Technology, P.O. Box 5048, 2600 GA Delft, The Netherlands; University of Chinese Academy of Sciences, Beijing, China
| | - Mingchen Yao
- Key Laboratory of Drinking Water Science and Technology, Research Centre for Eco-Environmental Sciences, Chinese Academy of Sciences, Beijing 100085, China; Sanitary Engineering, Department of Water Management, Faculty of Civil Engineering and Geosciences, Delft University of Technology, P.O. Box 5048, 2600 GA Delft, The Netherlands; University of Chinese Academy of Sciences, Beijing, China
| | - Jiaxing Fang
- Key Laboratory of Drinking Water Science and Technology, Research Centre for Eco-Environmental Sciences, Chinese Academy of Sciences, Beijing 100085, China; Science and Technology, University of Twente, P.O. Box 217, 7500AE Enschede, The Netherlands
| | - Zihan Dai
- Key Laboratory of Drinking Water Science and Technology, Research Centre for Eco-Environmental Sciences, Chinese Academy of Sciences, Beijing 100085, China; School of Civil and Environmental Engineering, Georgia Institute of Technology, Atlanta, GA 30332, USA
| | - Xiaoming Li
- Key Laboratory of Drinking Water Science and Technology, Research Centre for Eco-Environmental Sciences, Chinese Academy of Sciences, Beijing 100085, China; University of Chinese Academy of Sciences, Beijing, China.
| | - Walter van der Meer
- Science and Technology, University of Twente, P.O. Box 217, 7500AE Enschede, The Netherlands; Oasen Drinkwater, PO Box 122, 2800 AC, Gouda, The Netherlands
| | - Gertjan Medema
- Oasen Drinkwater, PO Box 122, 2800 AC, Gouda, The Netherlands; KWR Watercycle Research Institute, P.O. Box 1072, 3430 BB Nieuwegein, The Netherlands; Department of Fisheries and Wildlife, Michigan State University, East Lansing, MI 48823, USA
| | - Joan B Rose
- Department of Fisheries and Wildlife, Michigan State University, East Lansing, MI 48823, USA
| | - Gang Liu
- Key Laboratory of Drinking Water Science and Technology, Research Centre for Eco-Environmental Sciences, Chinese Academy of Sciences, Beijing 100085, China; Sanitary Engineering, Department of Water Management, Faculty of Civil Engineering and Geosciences, Delft University of Technology, P.O. Box 5048, 2600 GA Delft, The Netherlands; University of Chinese Academy of Sciences, Beijing, China.
| |
Collapse
|
5
|
Yang J, Hu Y, Zhang Y, Zhou S, Meng D, Xia S, Wang H. Deciphering the diversity and assemblage mechanisms of nontuberculous mycobacteria community in four drinking water distribution systems with different disinfectants. THE SCIENCE OF THE TOTAL ENVIRONMENT 2024; 907:168176. [PMID: 37907107 DOI: 10.1016/j.scitotenv.2023.168176] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 09/04/2023] [Revised: 10/25/2023] [Accepted: 10/26/2023] [Indexed: 11/02/2023]
Abstract
Nontuberculous mycobacteria (NTM) represent an emerging health concern due to their escalating infections worldwide. Although drinking water distribution systems (DWDSs) have been considered as NTM reservoirs and a potential infection route, NTM community at the species level remain largely elusive in DWDSs. This study employed high-throughput sequencing coupled with qPCR to profile NTM community and estimate their abundances at the species level in water and biofilm samples in four DWDSs using three different disinfectants (i.e. free chlorine, chloramine and chlorine dioxide). Results demonstrated the dominance of Mycobacterium paragordonae and Mycobacterium mucogenicum in both biofilm and water across four DWDSs, whereas Mycobacterium abscessus and Mycobacterium chelonae, the two clinically significant species, exhibited low abundance but high prevalence. Comparable NTM community was observed in biofilm across these four DWDSs. Distinct separation of NTM community between SH-chloramine DWDSs water and other DWDSs highlighted the selective pressure of chloramine on NTM community. Furthermore, the research revealed that biofilm and water exhibited distinct NTM community structures, with biofilm harboring more diverse NTM community. Certain NTM species displayed a preference for biofilm, such as Mycobacterium gordonae, while others, like Mycobacterium mucogenicum, were more abundant in water samples (P < 0.05). In terms of NTM community assembly, stochastic processes dominated biofilm, while comparable role of stochastic and deterministic processes was observed in water. In conclusion, this study offers a pioneering and comprehensive insight into the dynamics and assembly mechanisms of NTM community within four DWDSs treated with three distinct disinfectants. These findings serve as a critical foundation for assessing NTM exposure risks and devising effective management strategies within DWDSs.
Collapse
Affiliation(s)
- Jinhao Yang
- State Key Laboratory of Pollution Control and Resources Reuse, College of Environmental Science and Engineering, Tongji University, Shanghai 200092, China; Shanghai Institute of Pollution Control and Ecological Security, Shanghai 200092, China
| | - Yuxing Hu
- State Key Laboratory of Pollution Control and Resources Reuse, College of Environmental Science and Engineering, Tongji University, Shanghai 200092, China; Shanghai Institute of Pollution Control and Ecological Security, Shanghai 200092, China
| | - Yue Zhang
- State Key Laboratory of Pollution Control and Resources Reuse, College of Environmental Science and Engineering, Tongji University, Shanghai 200092, China; Shanghai Institute of Pollution Control and Ecological Security, Shanghai 200092, China
| | - Shuang Zhou
- School of Medicine, Tongji University, Shanghai 200092, China
| | - Die Meng
- Shanghai Pulmonary Hospital, Tongji University, Shanghai 200433, China
| | - Siqing Xia
- State Key Laboratory of Pollution Control and Resources Reuse, College of Environmental Science and Engineering, Tongji University, Shanghai 200092, China
| | - Hong Wang
- State Key Laboratory of Pollution Control and Resources Reuse, College of Environmental Science and Engineering, Tongji University, Shanghai 200092, China; Shanghai Institute of Pollution Control and Ecological Security, Shanghai 200092, China.
| |
Collapse
|
6
|
Ren X, Zhang S, Wu M, Xiao B, Miao H, Chen H. Effect and influence mechanism of biofilm formation on the biological stability of reclaimed water. THE SCIENCE OF THE TOTAL ENVIRONMENT 2024; 906:167735. [PMID: 37827320 DOI: 10.1016/j.scitotenv.2023.167735] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 04/15/2023] [Revised: 10/08/2023] [Accepted: 10/08/2023] [Indexed: 10/14/2023]
Abstract
Microorganisms and sediments in reclaimed water adhere to the inner walls of pipes or water tanks, forming biofilms that support the continuous growth of microorganisms. These biofilms provide a protective barrier, shielding bacteria from disinfectants. This study investigated the impact of biofilms on bacterial growth and reproduction in reclaimed water and the factors limiting bacterial growth in reclaimed graywater (GMR) and reclaimed mixed wastewater (MWR). The results revealed that biofilm biomass gradually increased and reached a maximum value on Days 20-25, and the biomass of organisms continued to decrease after 40 days. Biofilms serve as a source of bacteria, continuously releasing them into reclaimed water systems. The presence of biofilms reduced the biological stability of the reclaimed water, leading to water quality deterioration. The concentration of assimilable organic carbon in the reclaimed water showed a positive correlation with the heterotrophic bacterial count and Escherichia coli levels in both the reclaimed water and biofilms. The threshold value of chlorine for inhibiting biofilms in reclaimed water was no <2 mg/L. High concentrations of free chlorine delayed the growth of biofilms but did not reduce the final biomass generated by the biofilms. Carbon was the limiting factor for the biological stability of reclaimed water, while nitrogen, phosphorus, and inorganic salts were not limiting factors. Thus, minimizing the concentration of organic matter in reclaimed water can reduce the nutrient sources available for biofilm formation. This study provides support for advancements in the wastewater reuse industry.
Collapse
Affiliation(s)
- Xueli Ren
- School of Environment and Civil Engineering, Jiangnan University, Wuxi 214122, China.
| | - Shudong Zhang
- School of Ecological and Environmental Sciences, East China Normal University, Shanghai 200241, China
| | - Mengyi Wu
- School of Environment and Civil Engineering, Jiangnan University, Wuxi 214122, China
| | - Beiqi Xiao
- School of Environment and Civil Engineering, Jiangnan University, Wuxi 214122, China
| | - Hengfeng Miao
- School of Environment and Civil Engineering, Jiangnan University, Wuxi 214122, China
| | - Hongbin Chen
- State Key Laboratory of Pollution Control and Resource Reuse, College of Environmental Science and Engineering, Tongji University, Shanghai 200092, China.
| |
Collapse
|
7
|
Huang CK, Weerasekara A, Lu J, Carter R, Weynberg KD, Thomson R, Bell S, Guo J. Extended water stagnation in buildings during the COVID-19 pandemic increases the risks posed by opportunistic pathogens. WATER RESEARCH X 2023; 21:100201. [PMID: 38098883 PMCID: PMC10719583 DOI: 10.1016/j.wroa.2023.100201] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 12/21/2022] [Revised: 09/05/2023] [Accepted: 09/09/2023] [Indexed: 12/17/2023]
Abstract
The regrowth and subsequent exposure of opportunistic pathogens (OPs) whilst reopening buildings that have been locked down due to the stay-at-home restrictions to limit the spread of COVID-19, is a public health concern. To better understand such microbiological risks due to lowered occupancy and water demand in buildings, first and post-flush water samples (n = 48) were sampled from 24 drinking water outlets from eight university buildings in two campuses (urban and rural), with various end-user occupancies. Both campuses were served with chlorinated water originating from a single drinking water distribution system in South-East Queensland, situated 14 km apart, where the rural campus had lower chlorine residuals. Culture-dependent and culture-independent methods (such as flow cytometry, qPCR and 16S rRNA gene amplicon sequencing) were used concurrently to comprehensively characterise the OPs of interest (Legionella spp., Pseudomonas aeruginosa, and nontuberculous mycobacteria (NTM)) and the premise plumbing microbiome. Results showed that buildings with extended levels of stagnation had higher and diverse levels of microbial growth, as observed in taxonomic structure and composition of the microbial communities. NTM were ubiquitous in all the outlets sampled, regardless of campus or end-user occupancy of the buildings. qPCR and culture demonstrated prevalent and higher concentrations of NTM in buildings (averaging 3.25 log10[estimated genomic copies/mL]) with extended stagnation in the urban campus. Furthermore, flushing the outlets for 30 minutes restored residual and total chlorine, and subsequently decreased the levels of Legionella by a reduction of 1 log. However, this approach was insufficient to restore total and residual chlorine levels for the outlets in the rural campus, where both Legionella and NTM levels detected by qPCR remained unchanged, regardless of building occupancy. Our findings highlight that regular monitoring of operational parameters such as residual chlorine levels, and the implementation of water risk management plans are important for non-healthcare public buildings, as the levels of OPs in these environments are typically not assessed.
Collapse
Affiliation(s)
- Casey K Huang
- Australian Centre for Water and Environmental Biotechnology (ACWEB, formerly AWMC), The University of Queensland, QLD 4072, Australia
- Queensland Alliance for Environmental Health Sciences (QAEHS), The University of Queensland, QLD 4102, Australia
| | - Anjani Weerasekara
- Australian Centre for Water and Environmental Biotechnology (ACWEB, formerly AWMC), The University of Queensland, QLD 4072, Australia
- Queensland Alliance for Environmental Health Sciences (QAEHS), The University of Queensland, QLD 4102, Australia
| | - Ji Lu
- Australian Centre for Water and Environmental Biotechnology (ACWEB, formerly AWMC), The University of Queensland, QLD 4072, Australia
| | - Robyn Carter
- Respiratory Research Unit, Gallipoli Medical Research Institute, QLD 4120, Australia
| | - Karen D. Weynberg
- Australian Centre for Ecogenomics, School of Chemistry and Molecular Biosciences, The University of Queensland, St Lucia, Brisbane, QLD 4072, Australia
| | - Rachel Thomson
- Respiratory Research Unit, Gallipoli Medical Research Institute, QLD 4120, Australia
- Greenslopes Clinical Unit, The University of Queensland, QLD Australia
| | - Scott Bell
- Adult Cystic Fibrosis Centre, The Prince Charles Hospital, Australia
- Child Health Research Centre, Faculty of Medicine, The University of Queensland, QLD Australia
- Translational Research Institute, Australia
| | - Jianhua Guo
- Australian Centre for Water and Environmental Biotechnology (ACWEB, formerly AWMC), The University of Queensland, QLD 4072, Australia
| |
Collapse
|
8
|
Matanza XM, Clements A. Pathogenicity and virulence of Shigella sonnei: A highly drug-resistant pathogen of increasing prevalence. Virulence 2023; 14:2280838. [PMID: 37994877 PMCID: PMC10732612 DOI: 10.1080/21505594.2023.2280838] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/25/2023] [Accepted: 11/01/2023] [Indexed: 11/24/2023] Open
Abstract
Shigella spp. are the causative agent of shigellosis (or bacillary dysentery), a diarrhoeal disease characterized for the bacterial invasion of gut epithelial cells. Among the 4 species included in the genus, Shigella flexneri is principally responsible for the disease in the developing world while Shigella sonnei is the main causative agent in high-income countries. Remarkably, as more countries improve their socioeconomic conditions, we observe an increase in the relative prevalence of S. sonnei. To date, the reasons behind this change in aetiology depending on economic growth are not understood. S. flexneri has been widely used as a model to study the pathogenesis of the genus, but as more research data are collected, important discrepancies with S. sonnei have come to light. In comparison to S. flexneri, S. sonnei can be differentiated in numerous aspects; it presents a characteristic O-antigen identical to that of one serogroup of the environmental bacterium Plesiomonas shigelloides, a group 4 capsule, antibacterial mechanisms to outcompete and displace gut commensal bacteria, and a poorer adaptation to an intracellular lifestyle. In addition, the World Health Organization (WHO) have recognized the significant threat posed by antibiotic-resistant strains of S. sonnei, demanding new approaches. This review gathers knowledge on what is known about S. sonnei within the context of other Shigella spp. and aims to open the door for future research on understanding the increasing spread of this pathogen.
Collapse
Affiliation(s)
- Xosé M. Matanza
- Centre for Bacterial Resistance Biology, Department of Life Sciences, Imperial College London, London, UK
| | - Abigail Clements
- Centre for Bacterial Resistance Biology, Department of Life Sciences, Imperial College London, London, UK
| |
Collapse
|
9
|
Lefebvre M, Razakandrainibe R, Schapman D, François A, Genty D, Galas L, Villena I, Favennec L, Costa D. Interactions between free-living amoebae and Cryptosporidium parvum: an experimental study. Parasite 2023; 30:31. [PMID: 37606589 PMCID: PMC10443459 DOI: 10.1051/parasite/2023033] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/02/2023] [Accepted: 08/05/2023] [Indexed: 08/23/2023] Open
Abstract
Free-Living Amebae (FLA) and Cryptosporidium oocysts occasionally share the same environment. From 2004 to 2016, Cryptosporidium was responsible for 60% of 905 worldwide waterborne outbreaks caused by protozoan parasites. The aim of this study was to evaluate interactions between C. parvum oocysts and two common FLAs (Acanthamoeba castellanii and Vermamoeba vermiformis) in a water environment. Encystment and survival of FLAs were evaluated by microscopy using trypan blue vital coloration. Oocysts were numerated on microscopy. Interactions were studied over time in conditions both unfavorable and favorable to phagocytosis. Potential phagocytosis was directly evaluated by several microscopic approaches and indirectly by numeration of microorganisms and oocyst infectivity evaluation. Occasional phagocytosis of C. parvum by FLAs was documented. However, oocyst concentrations did not decrease significantly, suggesting resistance of oocysts to phagocytosis. A temporary decrease of oocyst infectivity was observed in the presence of A. castellanii. The effect of these interactions on C. parvum infectivity is particularly interesting. The biofilm condition could favor the persistence or even the proliferation of oocysts over time. This study demonstrated interactions between C. parvum and FLAs. Further knowledge of the mechanisms involved in the decrease of oocyst infectivity in the presence of A. castellanii could facilitate the development of new therapeutic approaches.
Collapse
Affiliation(s)
- Marion Lefebvre
- Univ Rouen Normandie, Laboratory of Parasitology-Mycology, EA7510 ESCAPE, University hospital of Rouen Normandie 76000 Rouen France
| | - Romy Razakandrainibe
- Univ Rouen Normandie, Laboratory of Parasitology-Mycology, EA7510 ESCAPE, University hospital of Rouen Normandie 76000 Rouen France
- National Reference Center Cryptosporidiosis, microsporidia and other protozoa, University Hospital of Rouen Normandie 76000 Rouen France
| | - Damien Schapman
- Univ Rouen Normandie, INSERM, CNRS, HeRacLeS US 51 UAR 2026, PRIMACEN 76000 Rouen France
| | - Arnaud François
- Univ Rouen Normandie, Laboratory of Parasitology-Mycology, EA7510 ESCAPE, University hospital of Rouen Normandie 76000 Rouen France
- Department of anathomopathology, University Hospital of Rouen Normandie 76000 Rouen France
| | - Damien Genty
- Department of anathomopathology, University Hospital of Rouen Normandie 76000 Rouen France
| | - Ludovic Galas
- Univ Rouen Normandie, INSERM, CNRS, HeRacLeS US 51 UAR 2026, PRIMACEN 76000 Rouen France
| | - Isabelle Villena
- Reims Champagne-Ardenne University, Laboratory of Parasitology-Mycology, EA7510 ESCAPE 51454 Reims France
| | - Loic Favennec
- Univ Rouen Normandie, Laboratory of Parasitology-Mycology, EA7510 ESCAPE, University hospital of Rouen Normandie 76000 Rouen France
- National Reference Center Cryptosporidiosis, microsporidia and other protozoa, University Hospital of Rouen Normandie 76000 Rouen France
| | - Damien Costa
- Univ Rouen Normandie, Laboratory of Parasitology-Mycology, EA7510 ESCAPE, University hospital of Rouen Normandie 76000 Rouen France
- National Reference Center Cryptosporidiosis, microsporidia and other protozoa, University Hospital of Rouen Normandie 76000 Rouen France
| |
Collapse
|
10
|
Song JJX, Oguma K. Mycobacterial contamination in tap and shower waters in Thailand. Lett Appl Microbiol 2023; 76:ovad090. [PMID: 37528059 DOI: 10.1093/lambio/ovad090] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/27/2023] [Revised: 07/23/2023] [Accepted: 07/31/2023] [Indexed: 08/03/2023]
Abstract
Waterborne disease is increasingly becoming associated with opportunistic premise plumbing pathogens (OPPPs), which can resist residual chlorination, regrow throughout drinking water distribution systems, and colonize premise plumbing. Nontuberculous mycobacteria (NTM) include clinically important species and exert a high burden on healthcare systems. We briefly report a qPCR-based survey of Mycobacterium spp. numbers in tap, POU-treated, and shower waters from Bangkok, Thailand. Non-stagnant tap waters and non-stagnant shower waters had mean numbers of 1.3 × 103 and 2.4 × 103 copies/mL, respectively. Water stagnation resulted in mean numbers higher by up to 1.0 log. The lowest number, 25 copies/mL, was obtained from a POU-treated sample, while the highest number, 2.0 × 104 copies/mL, came from a stagnant tap. Comparing with international data, mean numbers in this study were greater than those in nine out of 11 (82%) comparable studies, and the maximum numbers in this study were also high. Our samples of Bangkok waters exhibited relatively high Mycobacterium spp. numbers, suggesting the need for appropriate POU treatment systems where NTM infection is a health concern. This survey data can be used to set inactivation performance targets in POU water disinfection system design and may also lead to quantitative microbial risk assessment (QMRA) studies.
Collapse
Affiliation(s)
- Jack Jia Xin Song
- Department of Urban Engineering, The University of Tokyo, 7-3-1 Hongo, Bunkyo-ku, Tokyo 113-8654, Japan
| | - Kumiko Oguma
- Department of Urban Engineering, The University of Tokyo, 7-3-1 Hongo, Bunkyo-ku, Tokyo 113-8654, Japan
| |
Collapse
|
11
|
Hu D, Lin W, Zeng J, Zhang H, Wei Y, Yu X. To close or open the tank input water valve: Secondary water-supply systems with double tanks will induce a higher microbial risk. THE SCIENCE OF THE TOTAL ENVIRONMENT 2023; 874:162301. [PMID: 36801325 DOI: 10.1016/j.scitotenv.2023.162301] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 11/28/2022] [Revised: 01/25/2023] [Accepted: 02/13/2023] [Indexed: 06/18/2023]
Abstract
Secondary water supply systems (SWSSs) are widely used to supply water to high-rise households in urban residential buildings. A special mode of double tanks with one used while another was spared was noted in SWSSs, which would facilitate microbial growth due to longer water stagnation in the spare tank. There are limited studies on the microbial risk of water samples in such SWSSs. In this study, the input water valves of the operational SWSSs consisting of double tanks were artificially closed and opened on time. Propidium monoazide-qPCR and high-throughput sequencing were performed to systematically investigate the microbial risks in water samples. After closing the tank input water valve, it may take several weeks to replace the bulk water in the spare tank. The residual chlorine concentration in the spare tank decreased by up to 85 % within 2-3 days compared with that in the input water. The microbial communities in the spare and used tank water samples clustered separately. High bacterial 16S rRNA gene abundance and pathogens-like sequences were detected in the spare tanks. Most antibiotic-resistant genes (11/15) in the spare tanks showed an increase in their relative abundance. Moreover, when both tanks within one SWSS were in use, the water quality of the used tank water samples deteriorated to varying degrees. Overall, running SWSSs with double tanks will reduce the replacement rate of water in one storage tank, and consumers who use taps served by the presented SWSSs may have a higher microbial risk.
Collapse
Affiliation(s)
- Dong Hu
- School of Public Health, Shandong First Medical University & Shandong Academy of Medical Sciences, Jinan 250117, China
| | - Wenfang Lin
- Key Laboratory of Urban Environment and Health, Institute of Urban Environment, Chinese Academy of Sciences, Xiamen 361021, China
| | - Jie Zeng
- Department of Environmental Engineering, Graduate School of Engineering, Kyoto University, Kyoto University Katsura, Nishikyo, Kyoto 615-8540, Japan
| | - Heng Zhang
- College of the Environment & Ecology, Xiamen University, Xiamen 361102, China
| | - Yating Wei
- College of the Environment & Ecology, Xiamen University, Xiamen 361102, China
| | - Xin Yu
- College of the Environment & Ecology, Xiamen University, Xiamen 361102, China.
| |
Collapse
|
12
|
Baccari O, Barkallah M, Elleuch J, Ben Ayed N, Chtourou A, Karray-Hakim H, Hammami A, Michaud P, Fendri I, Abdelkafi S. Development of a duplex q-PCR for the simultaneous detection of Parachlamydia acanthamoebae and Simkania negevensis in environmental and clinical samples. Anal Biochem 2023; 667:115080. [PMID: 36775111 DOI: 10.1016/j.ab.2023.115080] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/21/2022] [Revised: 02/03/2023] [Accepted: 02/06/2023] [Indexed: 02/12/2023]
Abstract
Parachlamydia acanthamoebae and Simkania negevensis, two Chlamydia-like bacteria, have been recently recognized as emerging human respiratory pathogens. The prevalence and frequency of these bacteria in the environment and among atypical pneumonia patients are still underestimated by classical cultures, immunohistochemistry and serology which are non-specific, long and tedious methods. This study aims to develop a new duplex probe-based q-PCR assay for the simultaneous detection and quantification of P. acanthamoebae and S. negevensis. The selected hydrolysis probes displayed no cross-reaction with the closely related Chlamydia or the other tested waterborne pathogens. The assay achieved a large dynamic range for quantification (from 5 × 106 to 5 DNA copies/reaction). Efficiencies of FAM and JOE label probes weren't affected when they were combined. They were close to 100%, indicating the linear amplification. The application of this diagnostic tool resulted in 9/47 (19%) and 4/47 (8.5%) positive water samples for P. acanthamoebae and S. negevensis, respectively. P. acanthamoebae was also covered from 2/78 (2.5%) respiratory specimens and only one case (1/200 = 0.5%) of P. acanthamoebae and SARS-CoV-2 co-infection was noticed. While S. negevensis wasn't detected in clinical samples, the developed duplex q-PCR was shown to be an accurate, highly sensitive, and robust diagnostic tool for the detection and quantification of P. acanthamoebae and S. negevensis.
Collapse
Affiliation(s)
- Olfa Baccari
- Laboratoire de Génie Enzymatique et Microbiologie, Equipe de Biotechnologie des Algues, Ecole Nationale d'Ingénieurs de Sfax, Université de Sfax, 3038, Sfax, Tunisia
| | - Mohamed Barkallah
- Laboratoire de Génie Enzymatique et Microbiologie, Equipe de Biotechnologie des Algues, Ecole Nationale d'Ingénieurs de Sfax, Université de Sfax, 3038, Sfax, Tunisia
| | - Jihen Elleuch
- Laboratoire de Génie Enzymatique et Microbiologie, Equipe de Biotechnologie des Algues, Ecole Nationale d'Ingénieurs de Sfax, Université de Sfax, 3038, Sfax, Tunisia
| | - Nourelhouda Ben Ayed
- Laboratory of Microbiology, Faculty of Medicine of Sfax, Habib Bourguiba University Hospital, University of Sfax, Tunisia
| | - Amel Chtourou
- Laboratory of Microbiology, Faculty of Medicine of Sfax, Habib Bourguiba University Hospital, University of Sfax, Tunisia
| | - Héla Karray-Hakim
- Laboratory of Microbiology, Faculty of Medicine of Sfax, Habib Bourguiba University Hospital, University of Sfax, Tunisia
| | - Adenene Hammami
- Laboratory of Microbiology, Faculty of Medicine of Sfax, Habib Bourguiba University Hospital, University of Sfax, Tunisia
| | - Philippe Michaud
- Institut Pascal, Université Clermont Auvergne, CNRS, Clermont Auvergne INP, F-63000, Clermont-Ferrand, France
| | - Imen Fendri
- Laboratoire de Biotechnologie Végétale Appliquée à l'Amélioration des Cultures, Faculté des Sciences de Sfax, Université de Sfax, 3038, Sfax, Tunisia
| | - Slim Abdelkafi
- Laboratoire de Génie Enzymatique et Microbiologie, Equipe de Biotechnologie des Algues, Ecole Nationale d'Ingénieurs de Sfax, Université de Sfax, 3038, Sfax, Tunisia.
| |
Collapse
|
13
|
Mimura M, Koizumi Y, Wada M, Ichijo T, Uchii K, Nasu M. Microbial Water Quality Assessment of Private Wells Using 16S rRNA Gene Amplicon Sequencing with a Nanopore Sequencer. Biol Pharm Bull 2023; 46:263-271. [PMID: 36724954 DOI: 10.1248/bpb.b22-00690] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/03/2023]
Abstract
Private wells are used daily worldwide as convenient household water sources. In Japan, where water supply coverage is high, well water is occasionally used for non-potable purposes, such as irrigation and watering. Currently, the main microbiological test of well water is designed to detect Escherichia coli, which is an indicator of fecal contamination, using culture methods. Water use such as watering generates bioaerosols, which may cause airborne infection. However, many causative bacteria of aerosol-derived infections, such as Legionella spp., are difficult to detect using culture methods. Thus, more comprehensive modern assessment is desirable for securing the microbiological quality of well water. Here, the bacterial community structure of five private wells located in different environments was examined using the rapid and portable MinION sequencer, which enabled us to identify bacteria to the species level based on full-length 16S ribosomal RNA (rRNA) gene sequences. The results revealed the differences in the bacterial community structures of water samples from the five wells and detected Legionella pneumophila and Aeromonas hydrophila as new candidate microbial indicators. The comprehensive analysis method used in this study successfully detected bacteria causing opportunistic infections, which are difficult to detect by conventional methods. This approach is expected to be routinely applied in the future as a highly accurate method for assessing the microbiological quality of private well water.
Collapse
Affiliation(s)
- Mayumi Mimura
- Environmental Health Section, Osaka Institute of Public Health.,Graduate School of Pharmaceutical Sciences, Osaka Ohtani University
| | - Yoshihiko Koizumi
- Environmental Health Section, Osaka Institute of Public Health.,Graduate School of Pharmaceutical Sciences, Osaka Ohtani University
| | - Masashi Wada
- Research Institute of Environment, Agriculture and Fisheries, Osaka Prefecture
| | - Tomoaki Ichijo
- Faculty of Health and Nutrition, Osaka Shoin Women's University.,Graduate School of Human Sciences, Osaka Shoin Women's University
| | | | - Masao Nasu
- Graduate School of Pharmaceutical Sciences, Osaka Ohtani University
| |
Collapse
|
14
|
Zhou Q, Huang J, Guo K, Lou Y, Wang H, Zhou R, Tang J, Hou P. Spatiotemporal distribution of opportunistic pathogens and microbial community in centralized rural drinking water: One year survey in China. ENVIRONMENTAL RESEARCH 2023; 218:115045. [PMID: 36513125 DOI: 10.1016/j.envres.2022.115045] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 06/29/2022] [Revised: 11/18/2022] [Accepted: 12/09/2022] [Indexed: 06/17/2023]
Abstract
Centralized water supply in rural areas, supported by small waterworks (small-central mode) and by municipal water treatment plants (urban-extension mode), is an important guarantee to implement the Rural Revitalization Strategy Plan (2018-2022) in China. Opportunistic pathogens (OPs) could not be evaluated by the national drinking water sanitation standards in China (GB 5749-2022), posing potential microbial risks in rural drinking water. In this study, the spatiotemporal distribution of OPs, microbial community and the associated functional composition under two central water supply modes were investigated by molecular approaches. The results indicated that OPs were widely presented in the rural drinking water regardless of water supply modes, and were more abundant than those in the urban tap water. The insufficient residual chlorine and higher turbidity triggered more microbial proliferation, posing a seasonal variation of OPs gene copy numbers and bacterial community compositions. In warm seasons of summer and autumn, the gene copies of E. coli, M. avium, Pseudomonas spp. and the amoeba host Acanthamoeba spp. achieved up to 4.92, 3.94, 6.75 and 3.74 log10 (gene copies/mL), respectively. Potential functional prediction indicated higher relative abundance of pathogenic genes and infectious risks associated with the rural drinking water under small-central water supply mode. This one-year survey of the spatiotemporal distribution of OPs and microbial community provided scientific insights into microbial safety of rural drinking water, prompting attention on small-central water supply mode against OPs risks.
Collapse
Affiliation(s)
- Qiaomei Zhou
- College of Materials and Environmental Engineering, Hangzhou Dianzi University, Hangzhou, 310018, PR China.
| | - Jingang Huang
- College of Materials and Environmental Engineering, Hangzhou Dianzi University, Hangzhou, 310018, PR China; The Belt and Road Information Research Institute, Hangzhou Dianzi University, Hangzhou, 310018, PR China.
| | - Kangyin Guo
- College of Materials and Environmental Engineering, Hangzhou Dianzi University, Hangzhou, 310018, PR China; Zhejiang Sunrise Garment Group Co., Ltd., Shengzhou, 312400, PR China
| | - Yucheng Lou
- College of Materials and Environmental Engineering, Hangzhou Dianzi University, Hangzhou, 310018, PR China
| | - Haibo Wang
- Key Laboratory of Drinking Water Science and Technology, Research Center for Eco-Environmental Sciences, Chinese Academy of Sciences, Beijing, 100085, PR China.
| | - Rongbing Zhou
- College of Materials and Environmental Engineering, Hangzhou Dianzi University, Hangzhou, 310018, PR China
| | - Junhong Tang
- College of Materials and Environmental Engineering, Hangzhou Dianzi University, Hangzhou, 310018, PR China
| | - Pingzhi Hou
- The Belt and Road Information Research Institute, Hangzhou Dianzi University, Hangzhou, 310018, PR China
| |
Collapse
|
15
|
Aloraini S, Alum A, Abbaszadegan M. Impact of Pipe Material and Temperature on Drinking Water Microbiome and Prevalence of Legionella, Mycobacterium, and Pseudomonas Species. Microorganisms 2023; 11:microorganisms11020352. [PMID: 36838316 PMCID: PMC9966308 DOI: 10.3390/microorganisms11020352] [Citation(s) in RCA: 3] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/21/2022] [Revised: 01/26/2023] [Accepted: 01/28/2023] [Indexed: 02/04/2023] Open
Abstract
In drinking water distribution systems (DWDSs), pipe material and water temperature are some of the critical factors affecting the microbial flora of water. Six model DWDSs consisting of three pipe materials (galvanized steel, copper, and PEX) were constructed. The temperature in three systems was maintained at 22 °C and the other 3 at 32 °C to study microbial and elemental contaminants in a 6-week survey using 16S rRNA next-generation sequencing (NGS) and inductively coupled plasma-optical emission spectrometry (ICP-OES). Pipe material and temperature were preferentially linked with the composition of trace elements and the microbiome of the DWDSs, respectively. Proteobacteria was the most dominant phylum across all water samples ranging from 60.9% to 91.1%. Species richness (alpha diversity) ranking was PEX < steel ≤ copper system and elevated temperature resulted in decreased alpha diversity. Legionellaceae were omni-prevalent, while Mycobacteriaceae were more prevalent at 32 °C (100% vs. 58.6%) and Pseudomonadaceae at 22 °C (53.3% vs. 62.9%). Heterogeneity between communities was disproportionately driven by the pipe material and water temperature. The elevated temperature resulted in well-defined microbial clusters (high pseudo-F index) in all systems, with the highest impact in PEX (10.928) followed by copper (9.696) and steel (5.448). Legionellaceae and Mycobacteriaceae are preferentially prevalent in warmer waters. The results suggest that the water temperature has a higher magnitude of impact on the microbiome than the pipe material.
Collapse
Affiliation(s)
- Saleh Aloraini
- Department of Civil Engineering, College of Engineering, Qassim University, Buraydah 52571, Saudi Arabia
- School of Sustainable Engineering and the Built Environment, Arizona State University, Tempe, AZ 85281, USA
| | - Absar Alum
- School of Sustainable Engineering and the Built Environment, Arizona State University, Tempe, AZ 85281, USA
| | - Morteza Abbaszadegan
- School of Sustainable Engineering and the Built Environment, Arizona State University, Tempe, AZ 85281, USA
- Water and Environmental Technology Center, Arizona State University, Tempe, AZ 85281, USA
- Correspondence: ; Tel.: +1-480-965-3868
| |
Collapse
|
16
|
Shen Y, Haig SJ, Prussin AJ, LiPuma JJ, Marr LC, Raskin L. Shower water contributes viable nontuberculous mycobacteria to indoor air. PNAS NEXUS 2022; 1:pgac145. [PMID: 36712351 PMCID: PMC9802317 DOI: 10.1093/pnasnexus/pgac145] [Citation(s) in RCA: 5] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 12/20/2021] [Accepted: 11/07/2022] [Indexed: 11/11/2022]
Abstract
Nontuberculous mycobacteria (NTM) are frequently present in municipal drinking water and building plumbing, and some are believed to cause respiratory tract infections through inhalation of NTM-containing aerosols generated during showering. However, the present understanding of NTM transfer from water to air is insufficient to develop NTM risk mitigation strategies. This study aimed to characterize the contribution of shower water to the abundance of viable NTM in indoor air. Shower water and indoor air samples were collected, and 16S rRNA and rpoB genes were sequenced. The sequencing results showed that running the shower impacted the bacterial community structure and NTM species composition in indoor air by transferring certain bacteria from water to air. A mass balance model combined with NTM quantification results revealed that on average 1/132 and 1/254 of NTM cells in water were transferred to air during 1 hour of showering using a rain and massage showerhead, respectively. A large fraction of the bacteria transferred from water to air were membrane-damaged, i.e. they had compromised membranes based on analysis by live/dead staining and flow cytometry. However, the damaged NTM in air were recoverable as shown by growth in a culture medium mimicking the respiratory secretions of people with cystic fibrosis, implying a potential infection risk by NTM introduced to indoor air during shower running. Among the recovered NTM, Mycobacterium mucogenicum was the dominant species as determined by rpoB gene sequencing. Overall, this study lays the groundwork for future pathogen risk management and public health protection in the built environment.
Collapse
Affiliation(s)
| | | | - Aaron J Prussin
- Department of Civil and Environmental Engineering, Virginia Tech, 418 Durham Hall, Blacksburg, VA 24061, USA
| | - John J LiPuma
- Department of Pediatrics, University of Michigan Medical School, 1500 E. Medical Center Dr., Ann Arbor, MI 48109, USA
| | - Linsey C Marr
- Department of Civil and Environmental Engineering, Virginia Tech, 418 Durham Hall, Blacksburg, VA 24061, USA
| | | |
Collapse
|
17
|
Atkinson AJ, Morrison CM, Frehner W, Gerrity D, Wert EC. Design and operational considerations in response to Legionella occurrence in Las Vegas Valley groundwater. WATER RESEARCH 2022; 220:118615. [PMID: 35617788 DOI: 10.1016/j.watres.2022.118615] [Citation(s) in RCA: 2] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 04/01/2022] [Revised: 05/11/2022] [Accepted: 05/13/2022] [Indexed: 06/15/2023]
Abstract
Legionella occurrence monitoring is not required by United States Environmental Protection Agency (USEPA) drinking water regulations, and few occurrence studies exist for Legionella in source water or distribution systems. Legionella occurrence was monitored in Las Vegas Valley (Las Vegas, Nevada, USA) drinking water sources, including non-treated surface water, seasonal groundwater (61 wells, before and after chlorination), finished water (after treatment at water treatment facilities), and chlorinated distribution system water (at 9 reservoirs and 75 sample locations throughout the network). Legionella pneumophila was detected at least once at each of the wells sampled before chlorination, with an overall positivity rate of 38% (343/908). During well start-up (time<2 hours; turbidity>3 NTU), L. pneumophila concentrations averaged 2,792±353 MPN/100 mL, with a median of 105 MPN/100 mL, and range of <1 to 90,490 MPN/100 mL across 61 seasonally operated (typically April-October) groundwater wells. After initial flushing (turbidity<3 NTU), the average concentration decreased by more than two orders of magnitude to 24±3 MPN/100 mL but ranged from <1 to >2,273 MPN/100 mL. This trend indicates that stagnation (up to 391 days) contributed to greater initial concentrations, and flushing alone was incapable of complete L. pneumophila elimination. L. pneumophila concentration was significantly, positively correlated with total aqueous adenosine triphosphate (ATP) (p<0.00001, r=0.41-0.71), turbidity (p<0.00001, r=0.27-0.51), orthophosphate (p=0.35-0.076, r=0.51-0.59), and pump depth (p=0.032, r=0.40). During a full-scale assessment of chlorination (Ct=0.7 to 10.5 mg-min/L; T=26.6-28.1°C), substantial reduction of Legionella spp. (up to 2.5 logs) was observed; although, detectable concentrations were still measured. Extrapolating from a Chick-Watson model (log inactivation=0.28*(Ct); R2=0.87) constructed from the full-scale chlorination results, 3- and 4-log inactivation in Las Vegas Valley groundwater would require 10.8 and 14.3 mg-min/L, respectively; at least 3-log inactivation was required to bring Legionella spp. to below detection at the studied well. Chlorine exposure (Ct=0.1 to 10.9 mg-min/L) at most wells discharging directly to the distribution system was insufficient to fully inactivate Legionella spp. After discussing these findings with the state regulatory agency, direct-to-distribution wells (38 of 61 wells) remained out of operation; the distribution system, wells, and reservoirs were monitored for Legionella and chlorine residual, and additional treatment scenarios were identified for further evaluation. Legionella was either not detected or was well controlled in surface water, finished effluent from the drinking water treatment plant, chlorinated reservoirs, and the chlorinated distribution system. This study emphasizes the importance of utility-driven, non-regulatory research in order to protect public health and also identifies the need for greater occurrence monitoring and guidance for Legionella in groundwater supplies.
Collapse
Affiliation(s)
- Ariel J Atkinson
- Southern Nevada Water Authority (SNWA), P.O. Box 99954, Las Vegas, NV 89193-9954, United States.
| | - Christina M Morrison
- Southern Nevada Water Authority (SNWA), P.O. Box 99954, Las Vegas, NV 89193-9954, United States
| | - Wilbur Frehner
- Southern Nevada Water Authority (SNWA), P.O. Box 99954, Las Vegas, NV 89193-9954, United States
| | - Daniel Gerrity
- Southern Nevada Water Authority (SNWA), P.O. Box 99954, Las Vegas, NV 89193-9954, United States
| | - Eric C Wert
- Southern Nevada Water Authority (SNWA), P.O. Box 99954, Las Vegas, NV 89193-9954, United States
| |
Collapse
|
18
|
Mapili K, Rhoads WJ, Coughter M, Pieper KJ, Edwards MA, Pruden A. Occurrence of opportunistic pathogens in private wells after major flooding events: A four state molecular survey. THE SCIENCE OF THE TOTAL ENVIRONMENT 2022; 826:153901. [PMID: 35182640 DOI: 10.1016/j.scitotenv.2022.153901] [Citation(s) in RCA: 5] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 10/27/2021] [Revised: 02/10/2022] [Accepted: 02/11/2022] [Indexed: 06/14/2023]
Abstract
Private wells can become contaminated with waterborne pathogens during flooding events; however, testing efforts focus almost exclusively on fecal indicator bacteria. Opportunistic pathogens (OPs), which are the leading cause of identified waterborne disease in the United States, are understudied in private wells. We conducted a quantitative polymerase chain reaction survey of Legionella spp., L. pneumophila, Mycobacterium spp., M. avium, Naegleria fowleri, and shiga toxin-producing Escherichia coli gene markers and total coliform and E. coli in drinking water supplied by private wells following the Louisiana Floods (2016), Hurricane Harvey (2017), Hurricane Irma (2017), and Hurricane Florence (2018). Self-reported well characteristics and recovery status were collected via questionnaires. Of the 211 water samples collected, 40.3% and 5.2% were positive for total coliform and E. coli, which were slightly elevated positivity rates compared to prior work in coastal aquifers. DNA markers for Legionella and Mycobacterium were detected in 54.5% and 36.5% of samples, with L. pneumophila and M. avium detected in 15.6% and 17.1%, which was a similar positivity rate relative to municipal system surveys. Total bacterial 16S rRNA gene copies were positively associated with Legionella and Mycobacterium, indicating that conditions that favor occurrence of general bacteria can also favor OPs. N. fowleri DNA was detected in 6.6% of samples and was the only OP that was more prevalent in submerged wells compared to non-submerged wells. Self-reported well characteristics were not associated with OP occurrence. This study exposes the value of routine baseline monitoring and timely sampling after flooding events in order to effectively assess well water contamination risks.
Collapse
Affiliation(s)
- Kris Mapili
- Virginia Tech, Civil and Environmental Engineering, 418 Durham Hall, Blacksburg, VA 24061, United States of America
| | - William J Rhoads
- Virginia Tech, Civil and Environmental Engineering, 418 Durham Hall, Blacksburg, VA 24061, United States of America; Eawag - Swiss Federal Institute of Aquatic Science and Technology, Department of Environmental Microbiology, Überlandstrasse 133, 8600 Dübendorf, Switzerland.
| | - Mary Coughter
- Virginia Tech, Civil and Environmental Engineering, 418 Durham Hall, Blacksburg, VA 24061, United States of America
| | - Kelsey J Pieper
- Northeastern University, Civil and Environmental Engineering, 360 Huntington Ave., Boston, MA 02115, United States of America.
| | - Marc A Edwards
- Virginia Tech, Civil and Environmental Engineering, 418 Durham Hall, Blacksburg, VA 24061, United States of America
| | - Amy Pruden
- Virginia Tech, Civil and Environmental Engineering, 418 Durham Hall, Blacksburg, VA 24061, United States of America
| |
Collapse
|
19
|
Rahmatika I, Kurisu F, Furumai H, Kasuga I. Dynamics of the Microbial Community and Opportunistic Pathogens after Water Stagnation in the Premise Plumbing of a Building. Microbes Environ 2022; 37. [PMID: 35321996 PMCID: PMC8958293 DOI: 10.1264/jsme2.me21065] [Citation(s) in RCA: 7] [Impact Index Per Article: 3.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/12/2022] Open
Abstract
In premise plumbing, microbial water quality may deteriorate under certain conditions, such as stagnation. Stagnation results in a loss of disinfectant residual, which may lead to the regrowth of microorganisms, including opportunistic pathogens. In the present study, microbial regrowth was investigated at eight faucets in a building over four seasons in one year. Water samples were obtained before and after 24 h of stagnation. In the first 100 mL after stagnation, total cell counts measured by flow cytometry increased 14- to 220-fold with a simultaneous decrease in free chlorine from 0.17–0.36 mg L–1 to <0.02 mg L–1. After stagnation, total cell counts were not significantly different among seasons; however, the composition of the microbial community varied seasonally. The relative abundance of Pseudomonas spp. was dominant in winter, whereas Sphingomonas spp. were dominant in most faucets after stagnation in other seasons. Opportunistic pathogens, such as Legionella pneumophila, Mycobacterium avium, Pseudomonas aeruginosa, and Acanthamoeba spp., were below the quantification limit for real-time quantitative PCR in all samples. However, sequences related to other opportunistic pathogens, including L. feeleii, L. maceachernii, L. micdadei, M. paragordonae, M. gordonae, and M. haemophilum, were detected. These results indicate that health risks may increase after stagnation due to the regrowth of opportunistic pathogens.
Collapse
Affiliation(s)
- Iftita Rahmatika
- Department of Urban Engineering, Graduate School of Engineering, The University of Tokyo
| | - Futoshi Kurisu
- Research Center for Water Environment Technology, Graduate School of Engineering, The University of Tokyo
| | - Hiroaki Furumai
- Research Center for Water Environment Technology, Graduate School of Engineering, The University of Tokyo
| | - Ikuro Kasuga
- Department of Urban Engineering, Graduate School of Engineering, The University of Tokyo
| |
Collapse
|
20
|
Pfaller S, King D, Mistry JH, Donohue M. Occurrence revisited: Mycobacterium avium and Mycobacterium intracellulare in potable water in the USA. Appl Microbiol Biotechnol 2022; 106:2715-2727. [PMID: 35298694 PMCID: PMC9173748 DOI: 10.1007/s00253-022-11849-7] [Citation(s) in RCA: 4] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/02/2021] [Revised: 01/27/2022] [Accepted: 02/21/2022] [Indexed: 11/30/2022]
Abstract
Nontuberculous mycobacterium (NTM) infections are increasing in the USA and have a high cost burden associated with treatment. Thus, it is necessary to understand what changes could be contributing to this increase in NTM disease rate. Water samples from 40 sites were collected from around the USA. They represented three water types: groundwater disinfected with chlorine and surface water disinfected with chlorine or monochloramine. Two methods, culture and qPCR, were used to measure M. avium and M. intracellulare. Heterotrophic bacteria and NTM counts were also measured. M. avium and M. intracellulare were molecularly detected in 25% (73/292) and 35% (102/292) of samples. The mean concentrations of M. avium and M. intracellulare were 2.8 × 103 and 4.0 × 103 genomic units (GU) L-1. The Northeast sites had the highest sample positively rate for both M. avium and M. intracellulare. The highest NTM counts and M. avium concentrations were observed in the surface water treated with chloramine. Geographic location and source water/disinfectant type were observed to significantly influence M. avium and M. intracellulare occurrence rates. These studies can help improve public health risk management by balancing disinfectant treatments and diverse microbial loads in drinking water. KEY POINTS: • M. avium (MA) culture rate increased significantly: 1% (1999) to 13%. • Culture versus qPCR method: 13% vs 31% for MA and 6% vs 35% for MI. • The results of each method type tell two different stories of MA and MI occurrence.
Collapse
Affiliation(s)
- Stacy Pfaller
- Center for Exposure Research and Emergency Response, United States Environmental Protection Agency, 26 W. Martin Luther King Dr., Mail Stop 593, Cincinnati, OH, 45268, USA
| | - Dawn King
- Center for Exposure Research and Emergency Response, United States Environmental Protection Agency, 26 W. Martin Luther King Dr., Mail Stop 593, Cincinnati, OH, 45268, USA
| | - Jatin H Mistry
- United States Environmental Protection Agency, Region 6, Dallas, TX, USA
| | - Maura Donohue
- Center for Exposure Research and Emergency Response, United States Environmental Protection Agency, 26 W. Martin Luther King Dr., Mail Stop 593, Cincinnati, OH, 45268, USA.
| |
Collapse
|
21
|
Practitioners’ Perspective on the Prevalent Water Quality Management Practices for Legionella Control in Large Buildings in the United States. WATER 2022. [DOI: 10.3390/w14040663] [Citation(s) in RCA: 2] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 02/01/2023]
Abstract
Managing building water systems is complicated by the need to maintain hot water temperatures high enough to control the growth of Legionella spp. while minimizing the risk of scalding. This study assessed water quality management practices in large buildings in the United States. Surveys conducted with building water quality managers found that more than 85% of buildings have hot water temperatures that are consistent with scald risk mitigation guidelines (i.e., <122 °F/50 °C). However, nearly two thirds and three quarters of buildings do not comply with the common temperature guidance for opportunistic pathogen control, i.e., water heater setpoint > 140 °F (60 °C) and recirculation loop > 122 °F (50 °C), respectively; median values for both setpoint and recirculation loop temperatures are 10 °F (6 °C) or more below temperatures recommended for opportunistic pathogen control. These observations suggest that many buildings are prone to Legionella spp. risk. The study also found that 27% of buildings do not comply with guidelines for time to equilibrium hot water temperature, over 33% fail to monitor temperature in the recirculation loop, more than 70% fail to replace or disinfect showerheads, more than 40% lack a written management plan, and only a minority conduct any monitoring of residual disinfectant levels or microbiological quality. Given the rise in Legionellosis infections in recent years, coupled with highlighted water quality concerns because of prolonged water stagnation in plumbing, such as in buildings closed due to COVID-19, current management practices, which appear to be focused on scald risk, may need to be broadened to include greater attention to control of opportunistic pathogens. To accomplish this, there is a need for formal training and resources for facility managers.
Collapse
|
22
|
Prevalence of opportunistic pathogens in a school building plumbing during periods of low water use and a transition to normal use. Int J Hyg Environ Health 2022; 241:113945. [PMID: 35182850 DOI: 10.1016/j.ijheh.2022.113945] [Citation(s) in RCA: 2] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/15/2021] [Revised: 01/28/2022] [Accepted: 02/10/2022] [Indexed: 11/23/2022]
Abstract
The spread of opportunistic pathogens via building water supply and plumbing is of public health concern. This study was conducted to better understand microbial water quality changes in a LEED-certified school building during low water use (Summer) and normal water use (Autumn). The copper plumbed building contained water saving devices, a hot water recirculation system, and received chloraminated drinking water from a public water system. Three separate sampling events were conducted during the summer break inside the building and another three sampling events were conducted after the school returned to session. Using quantitative PCR, Legionella spp. were detected in all water samples, followed by Mycobacterium spp. (99%). Mycobacterium avium (75%) and Acanthamoeba spp. (17.5%) throughout the building water system. Legionella pneumophila and Naegleria fowleri were not detected in any of the samples. The mean concentrations of Legionella spp., Mycobacterium spp., Mycobacterium avium, and Acanthamoeba spp. detected in water samples were 3.9, 5.7, 4.7, and 2.8 log10 gene copies per 100 ml, respectively. There was a statistically significantly difference in the mean concentrations of Legionella spp., Mycobacterium spp. and M. avium gene markers in water samples between school breaks and when school was in session. Cultivable Legionella were also detected in water samples collected during periods of low water use. This study highlights the need for routine proactive water quality testing in school buildings to determine the extent of drinking water quality problems associated with plumbing and direct action to remediate microbial colonization.
Collapse
|
23
|
Yu Q, Feng T, Yang J, Su W, Zhou R, Wang Y, Zhang H, Li H. Seasonal distribution of antibiotic resistance genes in the Yellow River water and tap water, and their potential transmission from water to human. ENVIRONMENTAL POLLUTION (BARKING, ESSEX : 1987) 2022; 292:118304. [PMID: 34627965 DOI: 10.1016/j.envpol.2021.118304] [Citation(s) in RCA: 36] [Impact Index Per Article: 18.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 07/09/2021] [Revised: 09/05/2021] [Accepted: 10/05/2021] [Indexed: 05/25/2023]
Abstract
The prevalence and transmission of antibiotic resistance genes (ARGs) and opportunistic pathogens in water environments can pose great threat to public health. However, the dissemination of ARGs and opportunistic pathogens from water environments to humans has been poorly explored. Here, we employed 16S rRNA gene sequencing and high-throughput quantitative PCR techniques to explore the seasonal distribution of ARGs and opportunistic pathogens in the Yellow River water (source water) and tap water, as well as their relationships with healthy humans at Lanzhou, China. Physiochemical analysis was applied to detect water quality parameters and heavy metal contents. The absolute abundance and diversity of ARGs in the Yellow River and tap water demonstrated distinct seasonal patterns. In winter, the Yellow river water had the highest ARG abundance and diversity, while tap water owned the lowest. Mobile genetic elements (MGEs) were the predominant driver of ARG profiles in both the Yellow river and tap water. Null model analysis showed that ARG assembly in the Yellow River was more influenced by stochastic processes than tap water and this was independent of seasons. Total organic carbon and arsenic contents exhibited positive correlations with many ARGs. Opportunistic pathogens Aeromonas and Pseudomonas may be potential hosts for ARGs. Approximately 80% of detected ARGs were shared between water samples and the human gut. These persistent ARGs could not be entirely eliminated through drinking water treatment processes. Thus, it is crucial to protect sources of tap water from anthropogenic pollution and improve water treatment technologies to reduce the dissemination of ARGs and ensure drinking-water biosafety for human health.
Collapse
Affiliation(s)
- Qiaoling Yu
- School of Public Health, Lanzhou University, Lanzhou, 730000, China
| | - Tianshu Feng
- School of Public Health, Lanzhou University, Lanzhou, 730000, China
| | - Jiawei Yang
- School of Public Health, Lanzhou University, Lanzhou, 730000, China
| | - Wanghong Su
- School of Public Health, Lanzhou University, Lanzhou, 730000, China
| | - Rui Zhou
- School of Public Health, Lanzhou University, Lanzhou, 730000, China
| | - Yijie Wang
- School of Public Health, Lanzhou University, Lanzhou, 730000, China
| | - Hong Zhang
- Anhui Microanaly Gene Co., Ltd., Hefei, 230601, China
| | - Huan Li
- School of Public Health, Lanzhou University, Lanzhou, 730000, China; Center for Grassland Microbiome, Lanzhou University, Lanzhou, 730000, China.
| |
Collapse
|
24
|
The Impact of Extreme Weather Events on Bacterial Communities and Opportunistic Pathogens in a Drinking Water Treatment Plant. WATER 2021. [DOI: 10.3390/w14010054] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/16/2022]
Abstract
Drinking water treatment processes are highly effective at improving water quality, but pathogens can still persist in treated water, especially after extreme weather events. To identify how extreme weather events affected bacterial populations in source and treated water, water samples were collected from the Yangtze River Delta area and a local full-scale drinking water treatment plant. Bacterial community structure and the occurrence of pathogens were investigated in samples using 16S rRNA sequencing and qPCR techniques. In this study, the results show that intense rainfall can significantly increase levels of bacteria and opportunistic pathogens in river and drinking water treatment processes (p < 0.05); in particular, the relative abundance of Cyanobacteria increased after a super typhoon event (p < 0.05). The biological activated carbon (BAC) tank was identified as a potential pathogen reservoir and was responsible for 52 ± 6% of the bacteria released downstream, according to Bayesian-based SourceTracker analysis. Our results provide an insight into the challenges faced by maintaining finished water quality under changing weather conditions.
Collapse
|
25
|
Gleason JA, Cohn PD. A review of legionnaires' disease and public water systems - Scientific considerations, uncertainties and recommendations. Int J Hyg Environ Health 2021; 240:113906. [PMID: 34923288 DOI: 10.1016/j.ijheh.2021.113906] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/08/2021] [Revised: 12/02/2021] [Accepted: 12/13/2021] [Indexed: 11/17/2022]
Abstract
Legionella is an opportunistic premise plumbing pathogen and causative agent of a severe pneumonia called Legionnaires' Disease (LD). Cases of LD have been on the rise in the U.S. and globally. Although Legionella was first identified 45 years ago, it remains an 'emerging pathogen." Legionella is part of the normal ecology of a public water system and is frequently detected in regulatory-compliant drinking water. Drinking water utilities, regulators and public health alike are increasingly required to have a productive understanding of the evolving issues and complex discussions of the contribution of the public water utility to Legionella exposure and LD risk. This review provides a brief overview of scientific considerations important for understanding this complex topic, a review of findings from investigations of public water and LD, including data gaps, and recommendations for professionals interested in investigating public water utilities. Although the current literature is inconclusive in identifying a public water utility as a sole source of an LD outbreak, the evidence is clear that minimizing growth of Legionella in public water utilities through proper maintenance and sustained disinfectant residuals, throughout all sections of the water utility, will lead to a less conducive environment for growth of the bacteria in the system and the buildings they serve.
Collapse
Affiliation(s)
- Jessie A Gleason
- Environmental and Occupational Health Surveillance Program, New Jersey Department of Health, 135 E. State Street, P.O. Box 369, Trenton, NJ, 08625, USA.
| | - Perry D Cohn
- Retired, Environmental and Occupational Health Surveillance Program, New Jersey Department of Health, PO Box 369, Trenton, NJ, 08625, USA.
| |
Collapse
|
26
|
Schwake DO, Alum A, Abbaszadegan M. Legionella Occurrence beyond Cooling Towers and Premise Plumbing. Microorganisms 2021; 9:microorganisms9122543. [PMID: 34946143 PMCID: PMC8706379 DOI: 10.3390/microorganisms9122543] [Citation(s) in RCA: 8] [Impact Index Per Article: 2.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/06/2021] [Revised: 11/27/2021] [Accepted: 12/06/2021] [Indexed: 11/18/2022] Open
Abstract
Legionella is an environmental pathogen that is responsible for respiratory disease and is a common causative agent of water-related outbreaks. Due to their ability to survive in a broad range of environments, transmission of legionellosis is possible from a variety of sources. Unfortunately, a disproportionate amount of research that is devoted to studying the occurrence of Legionella in environmental reservoirs is aimed toward cooling towers and premise plumbing. As confirmed transmission of Legionella has been linked to many other sources, an over-emphasis on the most common sources may be detrimental to increasing understanding of the spread of legionellosis. This review aims to address this issue by cataloguing studies which have examined the occurrence of Legionella in less commonly investigated environments. By summarizing and discussing reports of Legionella in fresh water, ground water, saltwater, and distribution system drinking water, future environmental and public health researchers will have a resource to aid in investigating these pathogens in relevant sources.
Collapse
Affiliation(s)
- David Otto Schwake
- Department of Natural Sciences, Middle Georgia State University, 100 University Pkwy, Macon, GA 31206, USA;
| | - Absar Alum
- School of Sustainable Engineering and the Built Environment, Arizona State University, Tempe, AZ 85287, USA;
| | - Morteza Abbaszadegan
- School of Sustainable Engineering and the Built Environment, Arizona State University, Tempe, AZ 85287, USA;
- Correspondence: ; Tel.: +1-480-965-3868
| |
Collapse
|
27
|
Sevillano M, Vosloo S, Cotto I, Dai Z, Jiang T, Santiago Santana JM, Padilla IY, Rosario-Pabon Z, Velez Vega C, Cordero JF, Alshawabkeh A, Gu A, Pinto AJ. Spatial-temporal targeted and non-targeted surveys to assess microbiological composition of drinking water in Puerto Rico following Hurricane Maria. WATER RESEARCH X 2021; 13:100123. [PMID: 34704006 PMCID: PMC8524244 DOI: 10.1016/j.wroa.2021.100123] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 05/12/2021] [Revised: 09/28/2021] [Accepted: 09/30/2021] [Indexed: 05/05/2023]
Abstract
Loss of basic utilities, such as drinking water and electricity distribution, were sustained for months in the aftermath of Hurricane Maria's (HM) landfall in Puerto Rico (PR) in September 2017. The goal of this study was to assess if there was deterioration in biological quality of drinking water due to these disruptions. This study characterized the microbial composition of drinking water following HM across nine drinking water systems (DWSs) in PR and utilized an extended temporal sampling campaign to determine if changes in the drinking water microbiome were indicative of HM associated disturbance followed by recovery. In addition to monitoring water chemistry, the samples were subjected to culture independent targeted and non-targeted microbial analysis including quantitative PCR (qPCR) and genome-resolved metagenomics. The qPCR results showed that residual disinfectant was the major driver of bacterial concentrations in tap water with marked decrease in concentrations from early to late sampling timepoints. While Mycobacterium avium and Pseudomonas aeruginosa were not detected in any sampling locations and timepoints, genetic material from Leptospira and Legionella pneumophila were transiently detected in a few sampling locations. The majority of metagenome assembled genomes (MAGs) recovered from these samples were not associated with pathogens and were consistent with bacterial community members routinely detected in DWSs. Further, whole metagenome-level comparisons between drinking water samples collected in this study with samples from other full-scale DWS indicated no significant deviation from expected community membership of the drinking water microbiome. Overall, our results suggest that disruptions due to HM did not result in significant and sustained deterioration of biological quality of drinking water at our study sites.
Collapse
Affiliation(s)
- Maria Sevillano
- Department of Civil and Environmental Engineering, Northeastern University, Boston, MA, United States of America
| | - Solize Vosloo
- School of Civil and Environmental Engineering, Georgia Institute of Technology, Atlanta, GA, United States of America
| | - Irmarie Cotto
- Department of Civil and Environmental Engineering, Northeastern University, Boston, MA, United States of America
| | - Zihan Dai
- Key Laboratory of Drinking Water Science and Technology, Research Center for Eco-Environmental Sciences, Chinese Academy of Sciences, Beijing, China
- University of Chinese Academy of Sciences, Beijing, China
| | - Tao Jiang
- Department of Civil and Environmental Engineering, Northeastern University, Boston, MA, United States of America
| | - Jose M. Santiago Santana
- Department of Natural Sciences, University of Puerto Rico, Carolina, PR, United States of America
| | - Ingrid Y. Padilla
- Department of Civil Engineering and Surveying, University of Puerto Rico, Mayagüez, PR, United States of America
| | - Zaira Rosario-Pabon
- University of Puerto Rico—Medical Sciences Campus, San Juan, PR, United States of America
| | - Carmen Velez Vega
- University of Puerto Rico—Medical Sciences Campus, San Juan, PR, United States of America
| | - José F. Cordero
- Department of Epidemiology and Biostatistics, University of Georgia, Athens, Georgia, United States of America
| | - Akram Alshawabkeh
- Department of Civil and Environmental Engineering, Northeastern University, Boston, MA, United States of America
| | - April Gu
- School of Civil and Environmental Engineering, Cornell University, Ithaca, NY, United States of America
| | - Ameet J. Pinto
- School of Civil and Environmental Engineering, Georgia Institute of Technology, Atlanta, GA, United States of America
| |
Collapse
|
28
|
Zhang C, Lu J. Legionella: A Promising Supplementary Indicator of Microbial Drinking Water Quality in Municipal Engineered Water Systems. FRONTIERS IN ENVIRONMENTAL SCIENCE 2021; 9:1-22. [PMID: 35004706 PMCID: PMC8740890 DOI: 10.3389/fenvs.2021.684319] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/06/2023]
Abstract
Opportunistic pathogens (OPs) are natural inhabitants and the predominant disease causative biotic agents in municipal engineered water systems (EWSs). In EWSs, OPs occur at high frequencies and concentrations, cause drinking-water-related disease outbreaks, and are a major factor threatening public health. Therefore, the prevalence of OPs in EWSs represents microbial drinking water quality. Closely or routinely monitoring the dynamics of OPs in municipal EWSs is thus critical to ensuring drinking water quality and protecting public health. Monitoring the dynamics of conventional (fecal) indicators (e.g., total coliforms, fecal coliforms, and Escherichia coli) is the customary or even exclusive means of assessing microbial drinking water quality. However, those indicators infer only fecal contamination due to treatment (e.g., disinfection within water utilities) failure and EWS infrastructure issues (e.g., water main breaks and infiltration), whereas OPs are not contaminants in drinking water. In addition, those indicators appear in EWSs at low concentrations (often absent in well-maintained EWSs) and are uncorrelated with OPs. For instance, conventional indicators decay, while OPs regrow with increasing hydraulic residence time. As a result, conventional indicators are poor indicators of OPs (the major aspect of microbial drinking water quality) in EWSs. An additional or supplementary indicator that can well infer the prevalence of OPs in EWSs is highly needed. This systematic review argues that Legionella as a dominant OP-containing genus and natural inhabitant in EWSs is a promising candidate for such a supplementary indicator. Through comprehensively comparing the behavior (i.e., occurrence, growth and regrowth, spatiotemporal variations in concentrations, resistance to disinfectant residuals, and responses to physicochemical water quality parameters) of major OPs (e.g., Legionella especially L. pneumophila, Mycobacterium, and Pseudomonas especially P. aeruginosa), this review proves that Legionella is a promising supplementary indicator for the prevalence of OPs in EWSs while other OPs lack this indication feature. Legionella as a dominant natural inhabitant in EWSs occurs frequently, has a high concentration, and correlates with more microbial and physicochemical water quality parameters than other common OPs. Legionella and OPs in EWSs share multiple key features such as high disinfectant resistance, biofilm formation, proliferation within amoebae, and significant spatiotemporal variations in concentrations. Therefore, the presence and concentration of Legionella well indicate the presence and concentrations of OPs (especially L. pneumophila) and microbial drinking water quality in EWSs. In addition, Legionella concentration indicates the efficacies of disinfectant residuals in EWSs. Furthermore, with the development of modern Legionella quantification methods (especially quantitative polymerase chain reactions), monitoring Legionella in ESWs is becoming easier, more affordable, and less labor-intensive. Those features make Legionella a proper supplementary indicator for microbial drinking water quality (especially the prevalence of OPs) in EWSs. Water authorities may use Legionella and conventional indicators in combination to more comprehensively assess microbial drinking water quality in municipal EWSs. Future work should further explore the indication role of Legionella in EWSs and propose drinking water Legionella concentration limits that indicate serious public health effects and require enhanced treatment (e.g., booster disinfection).
Collapse
Affiliation(s)
- Chiqian Zhang
- Pegasus Technical Services, Inc., Cincinnati, OH, United States
| | - Jingrang Lu
- Office of Research and Development, United States Environmental Protection Agency, Cincinnati, OH, United States
- Correspondence: Jingrang Lu,
| |
Collapse
|
29
|
Wastewater-Based Surveillance of Antibiotic Resistance Genes Associated with Tuberculosis Treatment Regimen in KwaZulu Natal, South Africa. Antibiotics (Basel) 2021; 10:antibiotics10111362. [PMID: 34827300 PMCID: PMC8614817 DOI: 10.3390/antibiotics10111362] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/04/2021] [Revised: 10/15/2021] [Accepted: 10/28/2021] [Indexed: 12/15/2022] Open
Abstract
Essential components of public health include strengthening the surveillance of infectious diseases and developing early detection and prevention policies. This is particularly important for drug-resistant tuberculosis (DR-TB), which can be explored by using wastewater-based surveillance. This study aimed to use molecular techniques to determine the occurrence and concentration of antibiotic-resistance genes (ARGs) associated with tuberculosis (TB) resistance in untreated and treated wastewater. Raw/untreated and treated (post-chlorination) wastewater samples were taken from three wastewater treatment plants (WWTPs) in South Africa. The ARGs were selected to target drugs used for first- and second-line TB treatment. Both conventional polymerase chain reaction (PCR) and the more advanced droplet digital PCR (ddPCR) were evaluated as surveillance strategies to determine the distribution and concentration of the selected ARGs. The most abundant ARG in the untreated wastewater was the rrs gene, associated with resistance to the aminoglycosides, specifically streptomycin, with median concentration ranges of 4.69–5.19 log copies/mL. In contrast, pncA gene, associated with resistance to the TB drug pyrazinamide, was the least detected (1.59 to 2.27 log copies/mL). Resistance genes associated with bedaquiline was detected, which is a significant finding because this is a new drug introduced in South Africa for the treatment of multi-drug resistant TB. This study, therefore, establishes the potential of molecular surveillance of wastewater for monitoring antibiotic resistance to TB treatment in communities.
Collapse
|
30
|
Abukhalid N, Islam S, Ndzeidze R, Bermudez LE. Mycobacterium avium Subsp. hominissuis Interactions with Macrophage Killing Mechanisms. Pathogens 2021; 10:pathogens10111365. [PMID: 34832521 PMCID: PMC8623537 DOI: 10.3390/pathogens10111365] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/30/2021] [Revised: 09/30/2021] [Accepted: 10/18/2021] [Indexed: 11/16/2022] Open
Abstract
Non-tuberculosis mycobacteria (NTM) are ubiquitously found throughout the environment. NTM can cause respiratory infections in individuals with underlying lung conditions when inhaled, or systemic infections when ingested by patients with impaired immune systems. Current therapies can be ineffective at treating NTM respiratory infections, even after a long course or with multidrug treatment regimens. NTM, such as Mycobacterium avium subspecies hominissuis (M. avium), is an opportunistic pathogen that shares environments with ubiquitous free-living amoeba and other environmental hosts, possibly their evolutionary hosts. It is highly likely that interactions between M. avium and free-living amoeba have provided selective pressure on the bacteria to acquire survival mechanisms, which are also used against predation by macrophages. In macrophages, M. avium resides inside phagosomes and has been shown to exit it to infect other cells. M. avium’s adaptation to the hostile intra-phagosomal environment is due to many virulence mechanisms. M. avium is able to switch the phenotype of the macrophage to be anti-inflammatory (M2). Here, we have focused on and discussed the bacterial defense mechanisms associated with the intra-phagosome phase of infection. M. avium possesses a plethora of antioxidant enzymes, including the superoxide dismutases, catalase and alkyl hydroperoxide reductase. When these defenses fail or are overtaken by robust oxidative burst, many other enzymes exist to repair damage incurred on M. avium proteins, including thioredoxin/thioredoxin reductase. Finally, M. avium has several oxidant sensors that induce transcription of antioxidant enzymes, oxidation repair enzymes and biofilm- promoting genes. These expressions induce physiological changes that allow M. avium to survive in the face of leukocyte-generated oxidative stress. We will discuss the strategies used by M. avium to infect human macrophages that evolved during its evolution from free-living amoeba. The more insight we gain about M. avium’s mode of pathogenicity, the more targets we can have to direct new anti-virulence therapies toward.
Collapse
Affiliation(s)
- Norah Abukhalid
- Department of Biomedical Sciences, College of Veterinary Medicine, Oregon State University, Corvallis, OR 97331, USA; (N.A.); (S.I.); (R.N.)
| | - Sabrina Islam
- Department of Biomedical Sciences, College of Veterinary Medicine, Oregon State University, Corvallis, OR 97331, USA; (N.A.); (S.I.); (R.N.)
| | - Robert Ndzeidze
- Department of Biomedical Sciences, College of Veterinary Medicine, Oregon State University, Corvallis, OR 97331, USA; (N.A.); (S.I.); (R.N.)
| | - Luiz E. Bermudez
- Department of Biomedical Sciences, College of Veterinary Medicine, Oregon State University, Corvallis, OR 97331, USA; (N.A.); (S.I.); (R.N.)
- Department of Microbiology, College of Science, Oregon State University, Corvallis, OR 97331, USA
- Correspondence:
| |
Collapse
|
31
|
Webster TM, McFarland A, Gebert MJ, Oliverio AM, Nichols LM, Dunn RR, Hartmann EM, Fierer N. Structure and Functional Attributes of Bacterial Communities in Premise Plumbing Across the United States. ENVIRONMENTAL SCIENCE & TECHNOLOGY 2021; 55:14105-14114. [PMID: 34606240 DOI: 10.1021/acs.est.1c03309] [Citation(s) in RCA: 9] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/13/2023]
Abstract
Microbes that thrive in premise plumbing can have potentially important effects on human health. Yet, how and why plumbing-associated microbial communities vary across broad spatial scales remain undetermined. We characterized the bacterial communities in 496 showerheads collected from across the continental United States. The overall community structure, determined by 16S rRNA gene amplicon sequencing, revealed high levels of bacterial diversity. Although a large fraction of the observed variation in community composition could not be explained, differences in bacterial community composition were associated with water supply (private well water vs public municipal water), water source (groundwater vs surface water), and associated differences in water chemistry (pH and chlorine). Most notably, showerheads in homes supplied with public water had higher abundances of Blastomonas, Mycobacterium, and Porphyrobacter, while Pseudorhodoplanes, Novosphingobium, and Nitrospira were more abundant in those receiving private well water. We conducted shotgun metagenomic analyses on 92 of these samples to assess differences in genomic attributes. Public water-sourced showerheads had communities enriched in genes related to lipid and xenobiotic metabolisms, virulence factors, and antibiotic resistance. In contrast, genes associated with oxidative stress and membrane transporters were over-represented in communities from private well water-sourced showerheads compared to those supplied by public water systems. These results highlight the broad diversity of bacteria found in premise plumbing across the United States and the role of the water source and treatment in shaping the microbial community structure and functional potential.
Collapse
Affiliation(s)
- Tara M Webster
- Cooperative Institute for Research in Environmental Sciences, University of Colorado, Boulder, Colorado 80309, United States
| | - Alexander McFarland
- Department of Civil and Environmental Engineering, Northwestern University, 2145 Sheridan Road, Evanston, Illinois 60208, United States
| | - Matthew J Gebert
- Cooperative Institute for Research in Environmental Sciences, University of Colorado, Boulder, Colorado 80309, United States
- Department of Ecology and Evolutionary Biology, University of Colorado, Boulder, Colorado 80302, United States
| | - Angela M Oliverio
- Cooperative Institute for Research in Environmental Sciences, University of Colorado, Boulder, Colorado 80309, United States
- Department of Ecology and Evolutionary Biology, University of Colorado, Boulder, Colorado 80302, United States
| | - Lauren M Nichols
- Department of Applied Ecology, North Carolina State University, Raleigh, North Carolina 27607, United States
| | - Robert R Dunn
- Department of Applied Ecology, North Carolina State University, Raleigh, North Carolina 27607, United States
- Center for Evolutionary Hologenomics, University of Copenhagen, Copenhagen 1050, Denmark
| | - Erica M Hartmann
- Department of Civil and Environmental Engineering, Northwestern University, 2145 Sheridan Road, Evanston, Illinois 60208, United States
| | - Noah Fierer
- Cooperative Institute for Research in Environmental Sciences, University of Colorado, Boulder, Colorado 80309, United States
- Department of Ecology and Evolutionary Biology, University of Colorado, Boulder, Colorado 80302, United States
| |
Collapse
|
32
|
Zhang C, Struewing I, Mistry JH, Wahman DG, Pressman J, Lu J. Legionella and other opportunistic pathogens in full-scale chloraminated municipal drinking water distribution systems. WATER RESEARCH 2021; 205:117571. [PMID: 34628111 PMCID: PMC8629321 DOI: 10.1016/j.watres.2021.117571] [Citation(s) in RCA: 20] [Impact Index Per Article: 6.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 02/17/2021] [Revised: 08/02/2021] [Accepted: 08/13/2021] [Indexed: 05/06/2023]
Abstract
Water-based opportunistic pathogens (OPs) are a leading cause of drinking-water-related disease outbreaks, especially in developed countries such as the United States (US). Physicochemical water quality parameters, especially disinfectant residuals, control the (re)growth, presence, colonization, and concentrations of OPs in drinking water distribution systems (DWDSs), while the relationship between OPs and those parameters remain unclear. This study aimed to quantify how physicochemical parameters, mainly monochloramine residual concentration, hydraulic residence time (HRT), and seasonality, affected the occurrence and concentrations of four common OPs (Legionella, Mycobacterium, Pseudomonas, and Vermamoeba vermiformis) in four full-scale DWDSs in the US. Legionella as a dominant OP occurred in 93.8% of the 64 sampling events and had a mean density of 4.27 × 105 genome copies per liter. Legionella positively correlated with Mycobacterium, Pseudomonas, and total bacteria. Multiple regression with data from the four DWDSs showed that Legionella had significant correlations with total chlorine residual level, free ammonia concentration, and trihalomethane concentration. Therefore, Legionella is a promising indicator of water-based OPs, reflecting microbial water quality in chloraminated DWDSs. The OP concentrations had strong seasonal variations and peaked in winter and/or spring possibly because of reduced water usage (i.e., increased water stagnation or HRT) during cold seasons. The OP concentrations generally increased with HRT presumably because of disinfectant residual decay, indicating the importance of well-maintaining disinfectant residuals in DWDSs for OP control. The concentrations of Mycobacterium, Pseudomonas, and V. vermiformis were significantly associated with total chlorine residual concentration, free ammonia concentration, and pH and trihalomethane concentration, respectively. Overall, this study demonstrates how the significant spatiotemporal variations of OP concentrations in chloraminated DWDSs correlated with critical physicochemical water quality parameters such as disinfectant residual levels. This work also indicates that Legionella is a promising indicator of OPs and microbial water quality in chloraminated DWDSs.
Collapse
Affiliation(s)
- Chiqian Zhang
- Pegasus Technical Services, Inc., Cincinnati, Ohio, USA
| | - Ian Struewing
- Office of Research and Development, United States Environmental Protection Agency, Cincinnati, Ohio, USA
| | - Jatin H Mistry
- United States Environmental Protection Agency, Region 6, Dallas, Texas, USA
| | - David G Wahman
- Office of Research and Development, United States Environmental Protection Agency, Cincinnati, Ohio, USA
| | - Jonathan Pressman
- Office of Research and Development, United States Environmental Protection Agency, Cincinnati, Ohio, USA
| | - Jingrang Lu
- Office of Research and Development, United States Environmental Protection Agency, Cincinnati, Ohio, USA.
| |
Collapse
|
33
|
Han Z, Lu J, An W, Zhang Y, Yang M. Removal efficacy of opportunistic pathogen gene markers in drinking water supply systems: an in situ and large-scale molecular investigation. ENVIRONMENTAL SCIENCE AND POLLUTION RESEARCH INTERNATIONAL 2021; 28:54153-54160. [PMID: 34389952 DOI: 10.1007/s11356-021-15744-y] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 03/25/2021] [Accepted: 07/27/2021] [Indexed: 06/13/2023]
Abstract
The prevalence and interactions with biofilm and disinfectant of opportunistic pathogens in drinking water supply systems (DWSSs) have been extensively interpreted. In contrast, the large geographical distribution and in situ removal of opportunistic pathogens are overlooked aspects. Here, paired source and tap water samples of 36 parallel DWSSs across China were collected, with five common waterborne pathogens characterized by qPCR. From source to tap, the removal of bacterial biomass (16S rRNA gene copy number) was 1.10 log, and gene marker removal of five opportunistic pathogens ranged from 0.66 log to 2.27 log, with the order of Escherichia coli > Mycobacterium spp. > Clostridium perfringens > Bacillus cereus > Aeromonas hydrophila. Different with bacterial community, geographical location and source water types (river or reservoir) were not key contributor to variation of opportunistic pathogens. Gene marker removal efficacies of E. coli, Mycobacterium spp., and C. perfringens from source to tap were restricted to removal efficacy of overall bacterial biomass, while abundance of B. cereus in tap water linked to the input of B. cereus from source water. Although culture-dependent approach is important for pathogen enumeration in drinking water, qPCR-based molecular survey shows advantages of quantifiable high-throughput and easy operation, providing abundant and timely information on pathogen occurrence in water. This study provides the in situ, molecular-level evidence toward differential propagation features of multiple opportunistic pathogens in DWSSs and suggests the source protection and early warning of treatment-resistant pathogens.
Collapse
Affiliation(s)
- Ziming Han
- State Key Laboratory of Environmental Aquatic Chemistry, Research Center for Eco-Environmental Sciences, Chinese Academy of Sciences, Beijing, 100085, China
- University of Chinese Academy of Sciences, Beijing, 100049, China
| | - Junying Lu
- State Key Laboratory of Environmental Aquatic Chemistry, Research Center for Eco-Environmental Sciences, Chinese Academy of Sciences, Beijing, 100085, China
| | - Wei An
- Key Laboratory of Drinking Water Science and Technology, Research Center for Eco-Environmental Sciences, Chinese Academy of Sciences, Beijing, 100085, China
| | - Yu Zhang
- State Key Laboratory of Environmental Aquatic Chemistry, Research Center for Eco-Environmental Sciences, Chinese Academy of Sciences, Beijing, 100085, China.
- University of Chinese Academy of Sciences, Beijing, 100049, China.
| | - Min Yang
- University of Chinese Academy of Sciences, Beijing, 100049, China.
- Key Laboratory of Drinking Water Science and Technology, Research Center for Eco-Environmental Sciences, Chinese Academy of Sciences, Beijing, 100085, China.
| |
Collapse
|
34
|
Zhang X, Xia S, Ye Y, Wang H. Opportunistic pathogens exhibit distinct growth dynamics in rainwater and tap water storage systems. WATER RESEARCH 2021; 204:117581. [PMID: 34461496 DOI: 10.1016/j.watres.2021.117581] [Citation(s) in RCA: 9] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 05/17/2021] [Revised: 07/09/2021] [Accepted: 08/16/2021] [Indexed: 06/13/2023]
Abstract
Opportunistic pathogens (OPs) are emerging microbial contaminants in engineered water systems, yet their growth potential in rainwater systems has not been evaluated. The purpose of this study was to compare the growth dynamics of bacterial OPs and related genera (Pseudomonas aeruginosa, Legionella spp., L. pneumophila, Mycobacterium spp., and M. avium), two amoebal hosts (Acanthamoeba spp. and Vermamoeba vermiformis), and the fecal indicator Escherichia coli in simulated rainwater and tap water storage systems (SWSSs). Quantitative polymerase chain reaction (q-PCR) analysis of target microorganisms in SWSS influents and effluents demonstrated that P. aeruginosa and Legionella thrived in rainwater, but not in tap water. V. vermiformis proliferated in both rainwater and tap water polyvinyl chloride (PVC) SWSSs, while mycobacteria were largely absent in rainwater SWSSs. Tank materials exerted stronger influence on target microorganisms in rainwater SWSSs relative to tap water SWSSs, with species-specific responses noted in bulk water and biofilm. For instance, P. aeruginosa and V. vermiformis had the highest gene copy numbers in PVC rainwater SWSS effluents and biofilm, while Legionella peaked in stainless steel rainwater SWSS effluents and PVC rainwater SWSS biofilm. These results highlighted the OP contamination risks in rainwater storage systems and provided insights into rainwater system design and operation in terms of OP control.
Collapse
Affiliation(s)
- Xiaodong Zhang
- State Key Laboratory of Pollution Control and Resource Reuse, College of Environmental Science and Engineering, Tongji University, Shanghai 200092, China; Shanghai Chengtou Water Group Corporation, China; Shanghai Institute of Pollution Control and Ecological Security, Shanghai 200092, China
| | - Siqing Xia
- State Key Laboratory of Pollution Control and Resource Reuse, College of Environmental Science and Engineering, Tongji University, Shanghai 200092, China; Shanghai Institute of Pollution Control and Ecological Security, Shanghai 200092, China.
| | - Yinyin Ye
- Department of Civil, Structural and Environmental Engineering, University at Buffalo, Buffalo, New York 14260, USA
| | - Hong Wang
- State Key Laboratory of Pollution Control and Resource Reuse, College of Environmental Science and Engineering, Tongji University, Shanghai 200092, China; Shanghai Institute of Pollution Control and Ecological Security, Shanghai 200092, China.
| |
Collapse
|
35
|
Ghosh S, Zhu NJ, Milligan E, Falkinham JO, Pruden A, Edwards MA. Mapping the Terrain for Pathogen Persistence and Proliferation in Non-potable Reuse Distribution Systems: Interactive Effects of Biofiltration, Disinfection, and Water Age. ENVIRONMENTAL SCIENCE & TECHNOLOGY 2021; 55:12561-12573. [PMID: 34448580 DOI: 10.1021/acs.est.1c02121] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/13/2023]
Abstract
Diverse pathogens can potentially persist and proliferate in reclaimed water distribution systems (RWDSs). The goal of this study was to evaluate interactive effects of reclaimed water treatments and water age on persistence and proliferation of multiple fecal (e.g., Klebsiella, Enterobacter) and non-fecal (e.g., Legionella, mycobacteria) gene markers in RWDSs. Six laboratory-scale RWDSs were operated in parallel receiving the influent with or without biologically active carbon (BAC) filtration + chlorination, chloramination, or no disinfectant residual. After 3 years of operation, the RWDSs were subject to sacrificial sampling and shotgun metagenomic sequencing. We developed an in-house metagenome-derived pathogen quantification pipeline, validated by quantitative polymerase chain reaction and mock community analysis, to estimate changes in abundance of ∼30 genera containing waterborne pathogens. Microbial community composition in the RWDS bulk water, biofilm, and sediments was clearly shaped by BAC filtration, disinfectant conditions, and water age. Key commonalities were noted in the ecological niches occupied by fecal pathogen markers in the RWDSs, while non-fecal pathogen markers were more varied in their distribution. BAC-filtration + chlorine was found to most effectively control the widest range of target genera. However, filtration alone or chlorine secondary disinfection alone resulted in proliferation of some of these genera containing waterborne pathogens.
Collapse
Affiliation(s)
- Sudeshna Ghosh
- Department of Civil & Environmental Engineering, Virginia Tech, Blacksburg, Virginia 24060, United States
| | - Ni Joyce Zhu
- Department of Civil & Environmental Engineering, Virginia Tech, Blacksburg, Virginia 24060, United States
| | - Erin Milligan
- Department of Civil & Environmental Engineering, Virginia Tech, Blacksburg, Virginia 24060, United States
| | - Joseph O Falkinham
- Department of Biological Sciences, Virginia Tech, Blacksburg, Virginia 24060, United States
| | - Amy Pruden
- Department of Civil & Environmental Engineering, Virginia Tech, Blacksburg, Virginia 24060, United States
| | - Marc A Edwards
- Department of Civil & Environmental Engineering, Virginia Tech, Blacksburg, Virginia 24060, United States
| |
Collapse
|
36
|
Donohue MJ. Quantification of Legionella pneumophila by qPCR and culture in tap water with different concentrations of residual disinfectants and heterotrophic bacteria. THE SCIENCE OF THE TOTAL ENVIRONMENT 2021; 774:145142. [PMID: 33610980 PMCID: PMC8358786 DOI: 10.1016/j.scitotenv.2021.145142] [Citation(s) in RCA: 8] [Impact Index Per Article: 2.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 10/14/2020] [Revised: 01/07/2021] [Accepted: 01/08/2021] [Indexed: 05/21/2023]
Abstract
Legionellosis prevalence is increasing in the United States. This disease is caused primarily by the bacterium Legionella pneumophila found in water and transmitted by aerosol inhalation. This pathogen has a slow growth rate and can "hide" in amoeba, making it difficult to monitor by the traditional culture method on selective media. Tap water samples (n = 358) collected across the United States were tested for L. pneumophila by both culture and quantitative Polymerase Chain Reaction (qPCR). The presence of other bacteria was quantified by heterotrophic plate counts (HPC). Residual disinfectant concentrations (free chlorine or monochloramine) were measured in all samples. Legionella pneumophila had the highest prevalence and concentration in the chlorinated water samples that had a free‑chlorine value of less than 0.2 mg Cl2/L. In total, 24% (87/358) of the samples were positive for L. pneumophila either by qPCR or 3% (11/358) were positive by culture. In chloramine-treated samples, L. pneumophila was detected by qPCR in 21% (31/148) and 1% (2/148) by culture, despite a high monochloramine residual >1 mg Cl2/L. Despite the presence of a high disinfectant residual (>1 mg Cl2/L), HPC counts were substantial. This study indicates that both culture and qPCR methods have limitations when predicting a potential risk for disease associated with L. pneumophila in tap water. Measuring disinfectant residuals and quantifying HPC in water samples may be useful adjunct parameters for reducing Legionellosis' risk from public water supplies at high-risk locations.
Collapse
Affiliation(s)
- Maura J Donohue
- United States Environmental Protection Agency, Office Research and Development, Center for Environmental Solutions and Emergency Response, Cincinnati, OH 45268, United States of America.
| |
Collapse
|
37
|
Zhang C, Qin K, Struewing I, Buse H, Santo Domingo J, Lytle D, Lu J. The Bacterial Community Diversity of Bathroom Hot Tap Water Was Significantly Lower Than That of Cold Tap and Shower Water. Front Microbiol 2021; 12:625324. [PMID: 33967975 PMCID: PMC8102780 DOI: 10.3389/fmicb.2021.625324] [Citation(s) in RCA: 6] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/02/2020] [Accepted: 02/12/2021] [Indexed: 12/17/2022] Open
Abstract
Microbial drinking water quality in premise plumbing systems (PPSs) strongly affects public health. Bacterial community structure is the essential aspect of microbial water quality. Studies have elucidated the microbial community structure in cold tap water, while the microbial community structures in hot tap and shower water are poorly understood. We sampled cold tap, hot tap, and shower water from a simulated PPS monthly for 16 consecutive months and assessed the bacterial community structures in those samples via high-throughput sequencing of bacterial 16S rRNA genes. The total relative abundance of the top five most abundant phyla (Proteobacteria, Actinobacteria, Bacteroidetes, Cyanobacteria, and Firmicutes) was greater than 90% among the 24 identified phyla. The most abundant families were Burkholderiaceae, Sphingomonadaceae, unclassified Alphaproteobacteria, unclassified Corynebacteriales, and Mycobacteriaceae. A multiple linear regression suggests that the bacterial community diversity increased with water temperature and the age of the simulated PPS, decreased with total chlorine residual concentration, and had a limited seasonal variation. The bacterial community in hot tap water had significantly lower Shannon and Inverse Simpson diversity indices (p < 0.05) and thus a much lower diversity than those in cold tap and shower water. The paradoxical results (i.e., diversity increased with water temperature, but hot tap water bacterial community was less diverse) were presumably because (1) other environmental factors made hot tap water bacterial community less diverse, (2) the diversity of bacterial communities in all types of water samples increased with water temperature, and (3) the first draw samples of hot tap water could have a comparable or even lower temperature than shower water samples and the second draw samples of cold tap water. In both a three-dimensional Non-metric multidimensional scaling ordination plot and a phylogenetic dendrogram, the samples of cold tap and shower water cluster and are separate from hot tap water samples (p < 0.05). In summary, the bacterial community in hot tap water in the simulated PPS had a distinct structure from and a much lower diversity than those in cold tap and shower water.
Collapse
Affiliation(s)
- Chiqian Zhang
- Pegasus Technical Services, Inc., Cincinnati, OH, United States
| | - Ke Qin
- Oak Ridge Institute for Science and Education Participation Program, Office of Research and Development, United States Environmental Protection Agency, Cincinnati, OH, United States
| | - Ian Struewing
- Office of Research and Development, United States Environmental Protection Agency, Cincinnati, OH, United States
| | - Helen Buse
- Office of Research and Development, United States Environmental Protection Agency, Cincinnati, OH, United States
| | - Jorge Santo Domingo
- Office of Research and Development, United States Environmental Protection Agency, Cincinnati, OH, United States
| | - Darren Lytle
- Office of Research and Development, United States Environmental Protection Agency, Cincinnati, OH, United States
| | - Jingrang Lu
- Office of Research and Development, United States Environmental Protection Agency, Cincinnati, OH, United States
| |
Collapse
|
38
|
Masaka E, Reed S, Davidson M, Oosthuizen J. Opportunistic Premise Plumbing Pathogens. A Potential Health Risk in Water Mist Systems Used as a Cooling Intervention. Pathogens 2021; 10:pathogens10040462. [PMID: 33921277 PMCID: PMC8068904 DOI: 10.3390/pathogens10040462] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/03/2021] [Revised: 03/29/2021] [Accepted: 04/07/2021] [Indexed: 11/16/2022] Open
Abstract
Water mist systems (WMS) are used for evaporative cooling in public areas. The health risks associated with their colonization by opportunistic premise plumbing pathogens (OPPPs) is not well understood. To advance the understanding of the potential health risk of OPPPs in WMS, biofilm, water and bioaerosol samples (n = 90) from ten (10) WMS in Australia were collected and analyzed by culture and polymerase chain reaction (PCR) methods to detect the occurrence of five representative OPPPs: Legionella pneumophila, Pseudomonas aeruginosa, Mycobacterium avium, Naegleria fowleri and Acanthamoeba. P. aeruginosa (44%, n = 90) occurred more frequently in samples, followed by L. pneumophila serogroup (Sg) 2–14 (18%, n = 90) and L. pneumophila Sg 1 (6%, n = 90). A negative correlation between OPPP occurrence and residual free chlorine was observed except with Acanthamoeba, rs (30) = 0.067, p > 0.05. All detected OPPPs were positively correlated with total dissolved solids (TDS) except with Acanthamoeba. Biofilms contained higher concentrations of L. pneumophila Sg 2–14 (1000–3000 CFU/mL) than water samples (0–100 CFU/mL). This study suggests that WMS can be colonized by OPPPs and are a potential health risk if OPPP contaminated aerosols get released into ambient atmospheres.
Collapse
|
39
|
Fu Y, Peng H, Liu J, Nguyen TH, Hashmi MZ, Shen C. Occurrence and quantification of culturable and viable but non-culturable (VBNC) pathogens in biofilm on different pipes from a metropolitan drinking water distribution system. THE SCIENCE OF THE TOTAL ENVIRONMENT 2021; 764:142851. [PMID: 33097267 DOI: 10.1016/j.scitotenv.2020.142851] [Citation(s) in RCA: 25] [Impact Index Per Article: 8.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 07/02/2020] [Revised: 10/01/2020] [Accepted: 10/02/2020] [Indexed: 06/11/2023]
Abstract
Waterborne pathogens have been found in biofilms grown in drinking water distribution system (DWDS). However, there is a lack of quantitative study on the culturability of pathogens in biofilms from metropolitan DWDS. In this study, we quantified culturable and viable but non-culturable (VBNC) Escherichia coli, Salmonella enterica, Pseudomonas aeruginosa and Vibrio cholerae in biofilms collected from five kinds of pipes (galvanized steel pipe, steel pipe, stainless steel clad pipe, ductile cast iron pipe and polyethylene pipe) and associated drinking water at an actual chlorinated DWDS in use from China. The results of these comprehensive analyses revealed that pipe material is a significant factor influencing the culturability of pathogen and microbial communities. Network analysis of the culturable pathogens and 16S rRNA gene inferred potential interactions between microbiome and culturability of pathogens. Although the water quality met the Chinese national standard of drinking water, however, VBNC pathogens were detected in both biofilms and water from the DWDS. This investigation suggests that stainless steel clad pipe (SSCP) was a better choice for pathogen control compared with other metal pipes. To our knowledge, this is the first study on culturable and VBNC pathogens in biofilms of different pipe materials in metropolitan DWDS.
Collapse
Affiliation(s)
- Yulong Fu
- Department of Environmental Engineering, Zhejiang University, Hangzhou 310058, China
| | - Hongxi Peng
- Department of Civil Engineering, Zhejiang University, Hangzhou 310058, China
| | - Jingqing Liu
- Department of Civil Engineering, Zhejiang University, Hangzhou 310058, China
| | - Thanh H Nguyen
- Department of Civil and Environmental Engineering, University of Illinois at Urbana-Champaign, Urbana, IL 61801, United States
| | | | - Chaofeng Shen
- Department of Environmental Engineering, Zhejiang University, Hangzhou 310058, China.
| |
Collapse
|
40
|
Li Q, Yu S, Yang S, Yang W, Que S, Li W, Qin Y, Yu W, Jiang H, Zhao D. Eukaryotic community diversity and pathogenic eukaryotes in a full-scale drinking water treatment plant determined by 18S rRNA and metagenomic sequencing. ENVIRONMENTAL SCIENCE AND POLLUTION RESEARCH INTERNATIONAL 2021; 28:17417-17430. [PMID: 33394404 DOI: 10.1007/s11356-020-12079-y] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 03/10/2020] [Accepted: 12/14/2020] [Indexed: 06/12/2023]
Abstract
In this study, 18S rRNA high-throughput sequencing was applied to investigate the eukaryotic community in a full-scale drinking water treatment plant. Eukaryotic species and microbial functions in raw water and filter biofilms were identified by metagenomic sequencing. The eukaryotic species richness and diversity presented declining trends throughout the treatment process. The lowest eukaryotic species richness was observed in disinfected water. Arthropoda, Ciliophora, Ochrophyta, and Rotifera were the dominant eukaryotic phyla and exhibited high variations in relative abundance among the different treatment units. Sedimentation significantly decreased the abundance of all eukaryotes except Arthropoda. Biological activated carbon (BAC) filtration and chlorine disinfection exerted strong effects on community composition. The eukaryotic communities in water were distinct from those in filter biofilms, as were the communities of different filter biofilms from each other. In contrast, communities were functionally similar among different filter biofilms, with the category metabolism being the dominant category represented, within which amino acid transport and metabolism (E) and energy production and conversion (C) dominated among subcategories. Seventy-one eukaryotic species pathogenic to humans were identified in raw water and filter biofilms. Quantitative PCR (qPCR) results showed that Acanthamoeba spp. and Vermamoeba vermiformis were present during some treatment processes, with concentrations of 12-1.2 × 105 copies/mL and 1 copy/mL, respectively. Neither of the two pathogenic amoebae was found in disinfected water. Canonical correspondence analysis (CCA) showed that pH was the most important environmental factor affecting eukaryotic community composition. Overall, the results provide insights into the eukaryotic community diversity in drinking water treatment plants and the potential eukaryotic hazards involved in drinking water production.
Collapse
Affiliation(s)
- Qi Li
- National Inland Waterway Regulation Engineering Research Center, Chongqing Jiaotong University, Chongqing, 400074, China.
| | - Shuili Yu
- College of Environmental Science and Engineering, Tongji University, Shanghai, 200092, China.
| | - Shengfa Yang
- National Inland Waterway Regulation Engineering Research Center, Chongqing Jiaotong University, Chongqing, 400074, China
| | - Wei Yang
- National Inland Waterway Regulation Engineering Research Center, Chongqing Jiaotong University, Chongqing, 400074, China
| | - Sisi Que
- National Inland Waterway Regulation Engineering Research Center, Chongqing Jiaotong University, Chongqing, 400074, China
| | - Wenjie Li
- National Inland Waterway Regulation Engineering Research Center, Chongqing Jiaotong University, Chongqing, 400074, China
| | - Yu Qin
- Engineering Laboratory of Environmental & Hydraulic Engineering, Chongqing Municipal Development and Reform Commission, Chongqing Jiaotong University, Chongqing, 400074, China
| | - Weiwei Yu
- Engineering Laboratory of Environmental & Hydraulic Engineering, Chongqing Municipal Development and Reform Commission, Chongqing Jiaotong University, Chongqing, 400074, China
| | - Hui Jiang
- Engineering Laboratory of Environmental & Hydraulic Engineering, Chongqing Municipal Development and Reform Commission, Chongqing Jiaotong University, Chongqing, 400074, China
| | - Deqiang Zhao
- Engineering Laboratory of Environmental & Hydraulic Engineering, Chongqing Municipal Development and Reform Commission, Chongqing Jiaotong University, Chongqing, 400074, China
| |
Collapse
|
41
|
Keenum I, Medina MC, Garner E, Pieper KJ, Blair MF, Milligan E, Pruden A, Ramirez-Toro G, Rhoads WJ. Source-to-Tap Assessment of Microbiological Water Quality in Small Rural Drinking Water Systems in Puerto Rico Six Months After Hurricane Maria. ENVIRONMENTAL SCIENCE & TECHNOLOGY 2021; 55:3775-3785. [PMID: 33645970 DOI: 10.1021/acs.est.0c08814] [Citation(s) in RCA: 6] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/14/2023]
Abstract
Maria made a landfall in Puerto Rico on September 20, 2017 as a category 4 hurricane, causing severe flooding, widespread electricity outages, damage to infrastructure, and interruptions in water and wastewater treatment. Small rural community water systems face unique challenges in providing drinking water, which intensify after natural disasters. The purpose of this study was to evaluate the functionality of six very small rural public water systems and one large regulated system in Puerto Rico six months after Maria and survey a broad sweep of fecal, zoonotic, and opportunistic pathogens from the source to tap. Samples were collected from surface and groundwater sources, after water treatment and after distribution to households. Genes indicative of pathogenic Leptospira spp. were detected by polymerase chain reaction (PCR) in all systems reliant on surface water sources. Salmonella spp. was detected in surface and groundwater sources and some distribution system water both by culture and PCR. Legionella spp. and Mycobacteria spp. gene numbers measured by quantitative PCR were similar to nonoutbreak conditions in the continental U.S. Amplicon sequencing provided a nontarget screen for other potential pathogens of concern. This study aids in improving future preparedness, assessment, and recovery operations for small rural water systems after natural disasters.
Collapse
Affiliation(s)
- Ishi Keenum
- Department of Civil & Environmental Engineering, Virginia Tech, Blacksburg, Virginia 24060, United States
| | - Melitza Crespo Medina
- Center for Environmental Education, Conservation and Research, Inter American University, San Germán, Puerto Rico 00683, United States
| | - Emily Garner
- Department of Civil & Environmental Engineering, West Virginia University, Morgantown, West Virginia 26506, United States
| | - Kelsey J Pieper
- Department of Civil & Environmental Engineering, Northeastern University, Boston, Massachusetts 02115, United States
| | - Matthew Forrest Blair
- Department of Civil & Environmental Engineering, Virginia Tech, Blacksburg, Virginia 24060, United States
| | - Erin Milligan
- Department of Civil & Environmental Engineering, Virginia Tech, Blacksburg, Virginia 24060, United States
| | - Amy Pruden
- Department of Civil & Environmental Engineering, Virginia Tech, Blacksburg, Virginia 24060, United States
| | - Graciela Ramirez-Toro
- Center for Environmental Education, Conservation and Research, Inter American University, San Germán, Puerto Rico 00683, United States
| | - William J Rhoads
- Department of Civil & Environmental Engineering, Virginia Tech, Blacksburg, Virginia 24060, United States
| |
Collapse
|
42
|
Dahou S, Smahi MCE, Nouari W, Dahmani Z, Benmansour S, Ysmail-Dahlouk L, Miliani M, Yebdri F, Fakir N, Laoufi MY, Chaib-Draa M, Tourabi A, Aribi M. L-Threoascorbic acid treatment promotes S. aureus-infected primary human endothelial cells survival and function, as well as intracellular bacterial killing, and immunomodulates the release of IL-1β and soluble ICAM-1. Int Immunopharmacol 2021; 95:107476. [PMID: 33676147 DOI: 10.1016/j.intimp.2021.107476] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/09/2020] [Revised: 02/02/2021] [Accepted: 02/03/2021] [Indexed: 12/16/2022]
Abstract
BACKGROUND Vitamin C (ascorbic acid, AscH2) has been shown to enhance immunity. Here, we studied its immunomodulatory effect on human endothelial cells (ECs) during S. aureus infection. MATERIALS AND METHODS The ex vivo effects of AscH2 were performed on primary human umbilical vein endothelial cells (HUVECs) infected or not with S. aureus. RESULTS AscH2 treatment induced a marked downregulation of nitric oxide (NO) production and a moderate upregulation of arginase activity in S. aureus-infected HUVECs (respectively, p < 0.05 and p > 0.05). Although the upregulated release levels of soluble intercellular adhesion molecular 1 (sICAM-1/sCD54) and sE-selectin (sCD62E) molecules were not significantly different between treated and untreated S. aureus-infected HUVECs, AscH2 treatment induced reversing effect on sICAM-1 release when comparing to uninfected control HUVECs. Moreover, AscH2 treatment appears to have a significant effect on preventing HUVEC necrosis induced by S. aureus infection (p < 0.05). Furthermore, AscH2 treatment induced a significant upregulation of cell protective redox biomarker in S. aureus-infected, as shown by superoxide dismutase (SOD) activity (p < 0.05), but not by catalase activity (p > 0.05). Additionally, S. aureus infection markedly downregulated total bound calcium ions (bCa2+) levels as compared to control HUVECs, whereas, AscH2 treatment induced a slight upregulation of bCa2+ levels in infected HUVECs as compared to infected and untreated HUVECs (p > 0.05). On the other hand, AscH2 treatment downregulated increased total cellular cholesterol content (tccCHOL) levels in HUVECs induced by S. aureus infection (p < 0.05). In addition, AscH2 treatment markedly reversed S. aureus effect on upregulation of intracellular glucose (iGLU) levels within infected HUVECs (p < 0.05). Moreover, AscH2 treatment significantly downregulated S. aureus growth (p < 0.05), and significantly upregulated bacterial internalization and intracellular killing by HUVECs (p < 0.05), as well as their cell cycle activation (p < 0.01). Finally, AscH2 treatment has a slight effect on the production of interleukin 6 (IL-6), but induced a marked downregulation of that of IL-1β in S. aureus-infected HUVECs (respectively, p > 0.05, and p < 0.05). CONCLUSIONS Our outcomes demonstrated that, during S. aureus infection, AscH2 treatment promotes human ECs survival and function, as well as prevents inflammatory response exacerbation, while inducing bactericidal activity.
Collapse
Affiliation(s)
- Sara Dahou
- Laboratory of Applied Molecular Biology and Immunology, W0414100, University of Tlemcen, 13000 Tlemcen, Algeria
| | - Mohammed Chems-Eddine Smahi
- Laboratory of Applied Molecular Biology and Immunology, W0414100, University of Tlemcen, 13000 Tlemcen, Algeria; Neonatal Department of Specialized Maternal and Child Hospital of Tlemcen, 13000, Tlemcen, Algeria
| | - Wafa Nouari
- Laboratory of Applied Molecular Biology and Immunology, W0414100, University of Tlemcen, 13000 Tlemcen, Algeria
| | - Zoheir Dahmani
- Laboratory of Applied Molecular Biology and Immunology, W0414100, University of Tlemcen, 13000 Tlemcen, Algeria
| | - Souheila Benmansour
- Laboratory of Applied Molecular Biology and Immunology, W0414100, University of Tlemcen, 13000 Tlemcen, Algeria; Neonatal Department of Specialized Maternal and Child Hospital of Tlemcen, 13000, Tlemcen, Algeria
| | - Lamia Ysmail-Dahlouk
- Laboratory of Applied Molecular Biology and Immunology, W0414100, University of Tlemcen, 13000 Tlemcen, Algeria
| | - Maroua Miliani
- Laboratory of Applied Molecular Biology and Immunology, W0414100, University of Tlemcen, 13000 Tlemcen, Algeria
| | - Fadela Yebdri
- Laboratory of Applied Molecular Biology and Immunology, W0414100, University of Tlemcen, 13000 Tlemcen, Algeria
| | - Nassima Fakir
- Laboratory of Applied Molecular Biology and Immunology, W0414100, University of Tlemcen, 13000 Tlemcen, Algeria
| | - Mohammed Yassine Laoufi
- Laboratory of Applied Molecular Biology and Immunology, W0414100, University of Tlemcen, 13000 Tlemcen, Algeria; Neonatal Department of Specialized Maternal and Child Hospital of Tlemcen, 13000, Tlemcen, Algeria
| | - Mouad Chaib-Draa
- Laboratory of Applied Molecular Biology and Immunology, W0414100, University of Tlemcen, 13000 Tlemcen, Algeria
| | - Amina Tourabi
- Laboratory of Applied Molecular Biology and Immunology, W0414100, University of Tlemcen, 13000 Tlemcen, Algeria
| | - Mourad Aribi
- Laboratory of Applied Molecular Biology and Immunology, W0414100, University of Tlemcen, 13000 Tlemcen, Algeria.
| |
Collapse
|
43
|
Bal Krishna KC, Sathasivan A, Ginige MP. An assessment of the persistence of putative pathogenic bacteria in chloraminated water distribution systems. WATER RESEARCH 2021; 190:116677. [PMID: 33310436 DOI: 10.1016/j.watres.2020.116677] [Citation(s) in RCA: 6] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 05/28/2020] [Revised: 10/21/2020] [Accepted: 11/24/2020] [Indexed: 06/12/2023]
Abstract
This study investigated how a chloramine loss and nitrifying conditions influenced putative pathogenic bacterial diversity in bulk water and biofilm of a laboratory- and a full-scale chloraminated water distribution systems. Fifty-four reference databases containing full-length 16S rRNA gene sequences obtained from the National Centre for Biotechnology Information database were prepared to represent fifty-four pathogenic bacterial species listed in the World Health Organisation and Australian Drinking Water Quality Guidelines. When 16S rRNA gene sequences of all samples were screened against the fifty-four reference pathogenic databases, a total of thirty-one putative pathogenic bacteria were detected in both laboratory- and full-scale systems where total chlorine residuals ranged between 0.03 - 2.2 mg/L. Pathogenic bacterial species Mycolicibacterium fortuitum and Pseudomonas aeruginosa were noted in all laboratory (i.e. in bulk water and biofilm) and in bulk water of full-scale samples and Mycolicibacterium fortuitum dominated when chloramine residuals were high. Other different pathogenic bacterial species were observed dominant with decaying chloramine residuals. This study for the first time reports the diverse abundance of putative pathogenic bacteria resilient towards chloramine and highlights that metagenomics surveillance of drinking water can serve as a rapid assessment and an early warning of outbreaks of a large number of putative pathogenic bacteria.
Collapse
Affiliation(s)
- K C Bal Krishna
- School of Engineering, Western Sydney University, Locked Bag 1797, Penrith, NSW 2750, Australia.
| | - Arumugam Sathasivan
- School of Engineering, Western Sydney University, Locked Bag 1797, Penrith, NSW 2750, Australia
| | - Maneesha P Ginige
- CSIRO Land and Water, Private Bag No. 5, Wembley, WA, 6913, Australia
| |
Collapse
|
44
|
Xing X, Li T, Bi Z, Qi P, Li Z, Wang H, Lyu L, Gao Y, Hu C. Enhancing inhibition of disinfection byproducts formation and opportunistic pathogens growth during drinking water distribution by Fe 2O 3/Coconut shell activated carbon. ENVIRONMENTAL POLLUTION (BARKING, ESSEX : 1987) 2021; 268:115838. [PMID: 33099195 DOI: 10.1016/j.envpol.2020.115838] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 06/20/2020] [Revised: 10/07/2020] [Accepted: 10/10/2020] [Indexed: 06/11/2023]
Abstract
The effects of biological activated carbon treatment using Fe2O3 modified coconut shell-based activated carbon (Fe/CAC) were investigated on the occurrence of opportunistic pathogens (OPs) and formation of disinfection by-products (DBPs) in simulated drinking water distribution systems (DWDSs) with unmodified CAC as a reference. In the effluent of annular reactor (AR) with Fe/CAC, the OPs growth and DBPs formation were inhibited greatly. Based on the differential pulse voltammetry and dehydrogenase activity tests, it was verified that extracellular electron transfer was enhanced in the attached biofilms of Fe/CAC, hence improving the microbial metabolic activity and biological removal of organic matter especially DBPs precursors. Meanwhile, the extracellular polymeric substances (EPS) on the surface of Fe/CAC exhibited stronger viscosity, higher flocculating efficiency and better mechanical stability, avoiding bacteria or small-scale biofilms falling off into the water. Consequently, the microbial biomass and EPS substances amount decreased markedly in the effluent of Fe/CAC filter. More importantly, Fe/CAC did significantly enhance the shaping role on microbial community of downstream DWDSs, continuously excluding OPs advantage and inhibiting EPS production. The weakening of EPS in DWDSs resulted in decrease of microbial chlorine-resistance ability and EPS-derived DBPs precursors supply. Therefore, the deterioration of water quality in DWDSs was inhibited greatly, sustainably maintaining the safety of tap water. Our findings indicated that optimizing biological activated carbon treatment by interface modification is a promising method for improving water quality in DWDSs.
Collapse
Affiliation(s)
- Xueci Xing
- Institute of Environmental Research at Greater Bay, Key Laboratory for Water Quality and Conservation of the Pearl River Delta, Ministry of Education, Guangzhou University, Guangzhou, 510006, China
| | - Tong Li
- Institute of Environmental Research at Greater Bay, Key Laboratory for Water Quality and Conservation of the Pearl River Delta, Ministry of Education, Guangzhou University, Guangzhou, 510006, China
| | - Zhihao Bi
- Institute of Environmental Research at Greater Bay, Key Laboratory for Water Quality and Conservation of the Pearl River Delta, Ministry of Education, Guangzhou University, Guangzhou, 510006, China
| | - Peng Qi
- Institute of Environmental Research at Greater Bay, Key Laboratory for Water Quality and Conservation of the Pearl River Delta, Ministry of Education, Guangzhou University, Guangzhou, 510006, China
| | - Zesong Li
- Institute of Environmental Research at Greater Bay, Key Laboratory for Water Quality and Conservation of the Pearl River Delta, Ministry of Education, Guangzhou University, Guangzhou, 510006, China
| | - Haibo Wang
- Key Laboratory of Drinking Water Science and Technology, Research Center for Eco-Environmental Sciences, Chinese Academy of Sciences, Beijing, 100085, China
| | - Lai Lyu
- Institute of Environmental Research at Greater Bay, Key Laboratory for Water Quality and Conservation of the Pearl River Delta, Ministry of Education, Guangzhou University, Guangzhou, 510006, China
| | - Yaowen Gao
- Institute of Environmental Research at Greater Bay, Key Laboratory for Water Quality and Conservation of the Pearl River Delta, Ministry of Education, Guangzhou University, Guangzhou, 510006, China
| | - Chun Hu
- Institute of Environmental Research at Greater Bay, Key Laboratory for Water Quality and Conservation of the Pearl River Delta, Ministry of Education, Guangzhou University, Guangzhou, 510006, China.
| |
Collapse
|
45
|
Reyes‐Batlle M, Gabriel MF, Rodríguez‐Expósito R, Felgueiras F, Sifaoui I, Mourão Z, de Oliveira Fernandes E, Piñero JE, Lorenzo‐Morales J. Evaluation of the occurrence of pathogenic free-living amoeba and bacteria in 20 public indoor swimming pool facilities. Microbiologyopen 2021; 10:e1159. [PMID: 33650798 PMCID: PMC7859502 DOI: 10.1002/mbo3.1159] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/31/2020] [Revised: 12/16/2020] [Accepted: 12/22/2020] [Indexed: 11/24/2022] Open
Abstract
Recently, indoor swimming pool activities have increased to promote health-enhancing physical activities, which require establishing suitable protocols for disinfection and water quality control. Normally, the assessment of the microbial quality of the water in the pools only considers the presence of different bacteria. However, other less frequent but more resistant pathogens, such as free-living amoebas (FLA), are not contemplated in both existing recommendation and research activities. FLA represent a relevant human health risk, not only due to their pathogenicity but also due to the ability to act as vehicles of other pathogens, such as bacteria. Therefore, this work aimed to study the physicochemical characteristics and the occurrence of potentially pathogenic FLA and bacteria in water samples from 20 public indoor swimming facilities in Northern Portugal. Our results showed that some swimming pools presented levels of pH, free chlorine, and conductivity out of the recommended limits. Pathogenic FLA species were detected in two of the facilities under study, where we also report the presence of both, FLA and pathogenic bacteria. Our findings evidence the need to assess the occurrence of FLA and their existence in the same environmental niche as pathogenic bacteria in swimming pool facilities worldwide and to establish recommendations to safeguard the health of the users.
Collapse
Affiliation(s)
- María Reyes‐Batlle
- Instituto Universitario de Enfermedades Tropicales y Salud Pública de CanariasUniversidad de La LagunaTenerifeSpain
- Departamento de Obstetricia, Ginecología, Pediatría, Medicina Preventiva y Salud Pública, ToxicologíaMedicina Legal y Forense y ParasitologíaUniversidad De La LagunaTenerife, Islas CanariasSpain
- Red de Investigación Colaborativa en Enfermedades Tropicales (RICET)Spain
| | - Marta F. Gabriel
- INEGIInstitute of Science and Innovation in Mechanical and Industrial EngineeringPortoPortugal
| | - Rubén Rodríguez‐Expósito
- Instituto Universitario de Enfermedades Tropicales y Salud Pública de CanariasUniversidad de La LagunaTenerifeSpain
- Departamento de Obstetricia, Ginecología, Pediatría, Medicina Preventiva y Salud Pública, ToxicologíaMedicina Legal y Forense y ParasitologíaUniversidad De La LagunaTenerife, Islas CanariasSpain
| | - Fátima Felgueiras
- INEGIInstitute of Science and Innovation in Mechanical and Industrial EngineeringPortoPortugal
| | - Ines Sifaoui
- Instituto Universitario de Enfermedades Tropicales y Salud Pública de CanariasUniversidad de La LagunaTenerifeSpain
- Departamento de Obstetricia, Ginecología, Pediatría, Medicina Preventiva y Salud Pública, ToxicologíaMedicina Legal y Forense y ParasitologíaUniversidad De La LagunaTenerife, Islas CanariasSpain
- Red de Investigación Colaborativa en Enfermedades Tropicales (RICET)Spain
| | - Zenaida Mourão
- INEGIInstitute of Science and Innovation in Mechanical and Industrial EngineeringPortoPortugal
| | | | - José E. Piñero
- Instituto Universitario de Enfermedades Tropicales y Salud Pública de CanariasUniversidad de La LagunaTenerifeSpain
- Departamento de Obstetricia, Ginecología, Pediatría, Medicina Preventiva y Salud Pública, ToxicologíaMedicina Legal y Forense y ParasitologíaUniversidad De La LagunaTenerife, Islas CanariasSpain
- Red de Investigación Colaborativa en Enfermedades Tropicales (RICET)Spain
| | - Jacob Lorenzo‐Morales
- Instituto Universitario de Enfermedades Tropicales y Salud Pública de CanariasUniversidad de La LagunaTenerifeSpain
- Departamento de Obstetricia, Ginecología, Pediatría, Medicina Preventiva y Salud Pública, ToxicologíaMedicina Legal y Forense y ParasitologíaUniversidad De La LagunaTenerife, Islas CanariasSpain
- Red de Investigación Colaborativa en Enfermedades Tropicales (RICET)Spain
| |
Collapse
|
46
|
Dean K, Tamrakar S, Huang Y, Rose JB, Mitchell J. Modeling the Dose Response Relationship of Waterborne Acanthamoeba. RISK ANALYSIS : AN OFFICIAL PUBLICATION OF THE SOCIETY FOR RISK ANALYSIS 2021; 41:79-91. [PMID: 33047815 DOI: 10.1111/risa.13603] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 03/08/2019] [Revised: 06/30/2020] [Accepted: 07/26/2020] [Indexed: 06/11/2023]
Abstract
This study developed dose response models for determining the probability of eye or central nervous system infections from previously conducted studies using different strains of Acanthamoeba spp. The data were a result of animal experiments using mice and rats exposed corneally and intranasally to the pathogens. The corneal inoculations of Acanthamoeba isolate Ac 118 included varied amounts of Corynebacterium xerosis and were best fit by the exponential model. Virulence increased with higher levels of C. xerosis. The Acanthamoeba culbertsoni intranasal study with death as an endpoint of response was best fit by the beta-Poisson model. The HN-3 strain of A. castellanii was studied with an intranasal exposure and three different endpoints of response. For all three studies, the exponential model was the best fit. A model based on pooling data sets of the intranasal exposure and death endpoint resulted in an LD50 of 19,357 amebae. The dose response models developed in this study are an important step towards characterizing the risk associated with free-living amoeba like Acanthamoeba in drinking water distribution systems. Understanding the human health risk posed by free-living amoeba will allow for quantitative microbial risk assessments that support building design decisions to minimize opportunities for pathogen growth and survival.
Collapse
Affiliation(s)
- Kara Dean
- Department of Biosystems and Agricultural Engineering, Michigan State University, East Lansing, MI, USA
| | - Sushil Tamrakar
- Department of Fisheries and Wildlife, Michigan State University, East Lansing, MI, USA
- Freelancer
| | - Yin Huang
- Department of Fisheries and Wildlife, Michigan State University, East Lansing, MI, USA
- Current address: Office of Biostatistics and Epidemiology, Center for Biologics Evaluation and Research, Food and Drug Administration, Silver Spring, MD, USA
| | - Joan B Rose
- Department of Fisheries and Wildlife, Michigan State University, East Lansing, MI, USA
| | - Jade Mitchell
- Department of Biosystems and Agricultural Engineering, Michigan State University, East Lansing, MI, USA
| |
Collapse
|
47
|
Huang C, Sun PP, Won J, Wang Y, Boppart SA, Nguyen TH. Effect of Nonphosphorus Corrosion Inhibitors on Biofilm Pore Structure and Mechanical Properties. ENVIRONMENTAL SCIENCE & TECHNOLOGY 2020; 54:14716-14724. [PMID: 33124800 PMCID: PMC7949192 DOI: 10.1021/acs.est.0c04645] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/08/2023]
Abstract
Understanding the effects of biofilm structural and mechanical properties, which can influence biofilm cohesiveness and detachment under physical stress, is critical for biofilm and biofilm-associated pathogen control. In this study, we used optical coherence tomography (OCT) and nanoindentation to determine the role of silicate and tin (two experimental nonphosphate corrosion inhibitors) on the porous structure and stiffness of three types of multispecies biofilms. These biofilms were grown from groundwater (a drinking water source), and this groundwater was amended with either tin or silicate corrosion inhibitor (0.5 mg/L as Sn and 20 mg/L as SiO2). Based on the elastic moduli of these biofilms, tin biofilms and groundwater biofilms were the stiffest, followed by silicate biofilms. The thickness normalized by the growth time for silicate biofilms was highest at 38 ± 7.1 μm/month, compared to 21 ± 3.2 and 11 ± 2.4 μm/month for tin biofilms and groundwater biofilms, respectively. The silicate biofilms had the greatest overall porosities and were thickest among the three biofilms. Based on the pore network modeling (PNM) of OCT images, larger pores and connections were found in the silicate biofilms compared to those in tin and groundwater biofilms. Our analysis showed that the thicker and more porous biofilms (silicate biofilms) were potentially less resistant to deformation than the thinner and denser biofilms (tin and groundwater biofilms).
Collapse
Affiliation(s)
- Conghui Huang
- Department of Civil and Environmental Engineering, University of Illinois at Urbana-Champaign, Urbana, Illinois 61801, United States
| | - Peter P Sun
- Department of Civil and Environmental Engineering, University of Illinois at Urbana-Champaign, Urbana, Illinois 61801, United States
| | - Jungeun Won
- Departments of Electrical and Computer Engineering and Bioengineering, Beckman Institute for Advanced Science and Technology, University of Illinois at Urbana-Champaign, Urbana, Illinois 61801, United States
| | - Yin Wang
- Department of Civil and Environmental Engineering, University of Wisconsin-Milwaukee, Milwaukee, Wisconsin 53201, United States
| | - Stephen A Boppart
- Departments of Electrical and Computer Engineering and Bioengineering, Beckman Institute for Advanced Science and Technology, University of Illinois at Urbana-Champaign, Urbana, Illinois 61801, United States
- Carle Illinois College of Medicine, University of Illinois at Urbana-Champaign, Urbana, Illinois 61801, United States
| | - Thanh H Nguyen
- Department of Civil and Environmental Engineering, University of Illinois at Urbana-Champaign, Urbana, Illinois 61801, United States
- Institute of Genomic Biology, University of Illinois at Urbana-Champaign, Urbana, Illinois 61801, United States
- Carle Illinois College of Medicine, University of Illinois at Urbana-Champaign, Urbana, Illinois 61801, United States
| |
Collapse
|
48
|
Li S, Yang Z, Hu D, Cao L, He Q. Understanding building-occupant-microbiome interactions toward healthy built environments: A review. FRONTIERS OF ENVIRONMENTAL SCIENCE & ENGINEERING 2020; 15:65. [PMID: 33145119 PMCID: PMC7596174 DOI: 10.1007/s11783-020-1357-3] [Citation(s) in RCA: 9] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 07/04/2020] [Revised: 08/30/2020] [Accepted: 09/16/2020] [Indexed: 06/11/2023]
Abstract
Built environments, occupants, and microbiomes constitute a system of ecosystems with extensive interactions that impact one another. Understanding the interactions between these systems is essential to develop strategies for effective management of the built environment and its inhabitants to enhance public health and well-being. Numerous studies have been conducted to characterize the microbiomes of the built environment. This review summarizes current progress in understanding the interactions between attributes of built environments and occupant behaviors that shape the structure and dynamics of indoor microbial communities. In addition, this review also discusses the challenges and future research needs in the field of microbiomes of the built environment that necessitate research beyond the basic characterization of microbiomes in order to gain an understanding of the causal mechanisms between the built environment, occupants, and microbiomes, which will provide a knowledge base for the development of transformative intervention strategies toward healthy built environments. The pressing need to control the transmission of SARS-CoV-2 in indoor environments highlights the urgency and significance of understanding the complex interactions between the built environment, occupants, and microbiomes, which is the focus of this review.
Collapse
Affiliation(s)
- Shuai Li
- Department of Civil and Environmental Engineering, University of Tennessee, Knoxville, TN 37996 USA
| | - Zhiyao Yang
- Lyles School of Civil Engineering, Purdue University, West Lafayette, IN 47907 USA
| | - Da Hu
- Department of Civil and Environmental Engineering, University of Tennessee, Knoxville, TN 37996 USA
| | - Liu Cao
- Department of Civil and Environmental Engineering, University of Tennessee, Knoxville, TN 37996 USA
| | - Qiang He
- Department of Civil and Environmental Engineering, University of Tennessee, Knoxville, TN 37996 USA
- Institute for a Secure & Sustainable Environment, University of Tennessee, Knoxville, TN 37996 USA
| |
Collapse
|
49
|
Gomez-Alvarez V, Revetta RP. Monitoring of Nitrification in Chloraminated Drinking Water Distribution Systems With Microbiome Bioindicators Using Supervised Machine Learning. Front Microbiol 2020; 11:571009. [PMID: 33042076 PMCID: PMC7526508 DOI: 10.3389/fmicb.2020.571009] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/09/2020] [Accepted: 08/24/2020] [Indexed: 01/02/2023] Open
Abstract
Many drinking water utilities in the United States using chloramine as disinfectant treatment in their drinking water distribution systems (DWDS) have experienced nitrification episodes, which detrimentally impact the water quality. Identification of potential predictors of nitrification in DWDS may be used to optimize current nitrification monitoring plans and ultimately helps to safeguard drinking water and public health. In this study, we explored the water microbiome from a chloraminated DWDS simulator operated through successive operational schemes of stable and nitrification events and utilized the 16S rRNA gene dataset to generate high-resolution taxonomic profiles for bioindicator discovery. Analysis of the microbiome revealed both an enrichment and depletion of various bacterial populations associated with nitrification. A supervised machine learning approach (naïve Bayes classifier) trained with bioindicator profiles (membership and structure) were used to classify water samples. Performance of each model was examined using the area under the curve (AUC) from the receiver-operating characteristic (ROC) and precision-recall (PR) curves. The ROC- and PR-AUC gradually increased to 0.778 and 0.775 when genus-level membership (i.e., presence and absence) was used in the model and increased significantly using structure (i.e., distribution) dataset (AUCs = 1.000, p < 0.01). Community structure significantly improved the predictive ability of the model beyond that of membership only regardless of the type of data (sequence- or taxonomy-based model) we used to represent the microbiome. In comparison, an ATP-based model (bulk biomass) generated a lower AUCs of 0.477 and 0.553 (ROC and PR, respectively), which is equivalent to a random classification. A combination of eight bioindicators was able to correctly classify 85% of instances (nitrification or stable events) with an AUC of 0.825 (sensitivity: 0.729, specificity: 0.894) on a full-scale DWDS test set. Abiotic-based model using total Chlorine/NH2Cl and NH3 generated AUCs of 0.740 and 0.861 (ROC and PR, respectively), corresponding to a sensitivity of 0.250 and a specificity of 0.957. The AUCs increased to > 0.946 with the addition of NO2– concentration, which is indicative of nitrification in the DWDS. This research provides evidence of the feasibility of using bioindicators to predict operational failures in the system (e.g., nitrification).
Collapse
Affiliation(s)
- Vicente Gomez-Alvarez
- Office of Research and Development, United States Environmental Protection Agency, Cincinnati, OH, United States
| | - Randy P Revetta
- Office of Research and Development, United States Environmental Protection Agency, Cincinnati, OH, United States
| |
Collapse
|
50
|
Xue J, Zhang B, Lamori J, Shah K, Zabaleta J, Garai J, Taylor CM, Sherchan SP. Molecular detection of opportunistic pathogens and insights into microbial diversity in private well water and premise plumbing. JOURNAL OF WATER AND HEALTH 2020; 18:820-834. [PMID: 33095203 PMCID: PMC9115838 DOI: 10.2166/wh.2020.271] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/10/2023]
Abstract
Private well water systems in rural areas that are improperly maintained will result in poor drinking water quality, loss of water supply, and pose human health risk. The purpose of this study was to investigate the occurrence of fecal indicator bacteria (FIB) and opportunistic pathogens in private well water in rural areas surrounding New Orleans, Louisiana. Our results confirmed the ubiquitous nature of Legionella (86.7%) and mycobacteria (68.1%) in private well water in the study area, with gene concentration ranged from 0.60 to 5.53 and 0.67 to 5.95 Log10 of GC/100 mL, respectively. Naegleria fowleri target sequence was detected in 16.8% and Escherichia coli was detected in 43.4% of the water samples. Total coliform, as well as Legionella and mycobacteria genetic markers' concentrations were significantly reduced by 3-minute flushing. Next-generation sequencing (NGS) data indicated that the abundance of bacterial species was significantly increased in water collected in kitchens compared with samples from wells directly. This study provided integrated knowledge on the persistence of pathogenic organisms in private well water. Further study is needed to explore the presence of clinical species of those opportunistic pathogens in private well water systems to elucidate the health risk.
Collapse
Affiliation(s)
- Jia Xue
- Department of Environmental Health Sciences, School of Public Health and Tropical Medicine, Tulane University, New Orleans, Louisiana, 70112, USA E-mail:
| | - Bowen Zhang
- Department of Natural Resources and Environmental Management, Ball State University, Muncie, Indiana, 47306, USA
| | - Jennifer Lamori
- Department of Environmental Health Sciences, School of Public Health and Tropical Medicine, Tulane University, New Orleans, Louisiana, 70112, USA E-mail:
| | - Kinjal Shah
- Department of Environmental Health Sciences, School of Public Health and Tropical Medicine, Tulane University, New Orleans, Louisiana, 70112, USA E-mail:
| | - Jovanny Zabaleta
- Department of Pediatrics and Stanley S. Scott Cancer Center, Louisiana State University Health Sciences Center, Louisiana Cancer Research Center, New Orleans, Louisiana, 70112, USA
| | - Jone Garai
- Department of Pediatrics and Stanley S. Scott Cancer Center, Louisiana State University Health Sciences Center, Louisiana Cancer Research Center, New Orleans, Louisiana, 70112, USA
| | - Christopher M Taylor
- Department of Microbiology, Immunology & Parasitology, Louisiana State University Health Sciences Center, New Orleans, Louisiana, 70112, USA
| | - Samendra P Sherchan
- Department of Environmental Health Sciences, School of Public Health and Tropical Medicine, Tulane University, New Orleans, Louisiana, 70112, USA E-mail:
| |
Collapse
|