Molecular Detection and Characterization of HIV‐1. Mol Microbiol 2011. [DOI: 10.1128/9781555816834.ch35] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/20/2022]
|
2
|
Evaluation of the Abbott m2000rt RealTime HIV-1 assay with manual sample preparation compared with the ROCHE COBAS AmpliPrep/AMPLICOR HIV-1 MONITOR v1.5 using specimens from East Africa. J Virol Methods 2009; 162:218-22. [PMID: 19729037 DOI: 10.1016/j.jviromet.2009.08.013] [Citation(s) in RCA: 31] [Impact Index Per Article: 2.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/24/2009] [Revised: 08/13/2009] [Accepted: 08/25/2009] [Indexed: 12/27/2022]
Abstract
The performance of the Abbott m2000rt RealTime HIV-1 assay (RealTime HIV-1) with manual sample preparation was compared against the ROCHE COBAS AmpliPrep/AMPLICOR HIV-1 MONITOR Test v1.5 (CAP/CA HIV-1) using samples collected from 100 donors infected with HIV and 20 donors not infected with HIV in northern Tanzania where HIV-1 subtypes A, C, D, and their recombinant forms predominate. The RealTime HIV-1 appeared to have more within-run variability at high HIV-1 RNA concentrations, but total assay variability over the dynamic range tested was within the manufacturer's claim of <0.3 SD copies/mL. Accuracy studies showed 100% concordance for positive and negative values. When continuous values were examined, CAP/CA HIV-1 yielded higher values than the RealTime HIV-1 at higher nominal HIV-1 RNA concentrations. The RealTime HIV-1 assay showed excellent linearity between 2.5 and 7.0 log copies/mL. Of negative samples, 100% showed negative results, and >95% of samples with nominal concentrations of 40 copies/mL were detected at > or = 40 copies/mL by RealTime HIV-1. Manual sample preparation may contribute to higher total assay variability. This study suggests that the Abbott m2000rt RealTime HIV-1 assay with manual sample preparation is an acceptable and feasible alternative to the conventional ROCHE COBAS AmpliPrep/AMLICOR HIV-1 Monitor v1.5 assay and that the RealTime HIV-1 assay performs well on samples from East Africa.
Collapse
|
3
|
A novel real-time multiplex reverse transcriptase-polymerase chain reaction for the detection of HIV-1 RNA by using dual-specific armored RNA as internal control. Intervirology 2008; 51:42-9. [PMID: 18311080 DOI: 10.1159/000119119] [Citation(s) in RCA: 10] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/04/2007] [Accepted: 01/22/2008] [Indexed: 11/19/2022] Open
Abstract
OBJECTIVE Transmission of HIV-1 and diagnosis of infection in hospitals and public health settings remains a worldwide concern. HIV-1 detection is sometimes not possible using current commercial assays, probably due to mismatches between the selected primers and probes. METHODS By screening primers and probes, we developed a dual-specificity probe real-time reverse transcriptase-polymerase chain reaction (DSPrtRT-PCR) assay using dual-specific armored RNA as the internal control. The specificity and sensitivity were compared between the monospecificity probe real-time and DSPrtRT-PCR techniques. RESULTS The sensitivity of DSPrtRT-PCR improved significantly, with no effect on its specificity. The detection limit was 173 IU/ml. All the HIV-1 group M and group O could be detected. In clinical assays, 1,000 copies/ml of armored RNA was required as internal control. When applied to negative samples, 100% specificity was achieved. Among 60 samples from the tested patients, DSPrtRT-PCR demonstrated high sensitivity, accurately detecting 50 positives and 10 negatives that were confirmed by the COBAS AmpliScreen assay. CONCLUSION DSPrtRT-PCR is a more efficient and effective viral assay with high sensitivity and specificity as compared to monospecificity probe PCR. It can be widely applied in blood donor screening and qualitative individual detection of HIV-1 RNA.
Collapse
|
4
|
A RealTime HIV-1 viral load assay for automated quantitation of HIV-1 RNA in genetically diverse group M subtypes A–H, group O and group N samples. J Virol Methods 2007; 146:236-45. [PMID: 17707519 DOI: 10.1016/j.jviromet.2007.07.003] [Citation(s) in RCA: 70] [Impact Index Per Article: 4.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/09/2007] [Revised: 07/03/2007] [Accepted: 07/09/2007] [Indexed: 12/31/2022]
Abstract
The Abbott RealTime HIV-1 assay is an automated test for monitoring HIV-1 viral load in plasma samples. The assay uses reverse transcription polymerase chain reaction (RT-PCR) technology with homogeneous real-time fluorescent detection. Automated sample preparation is performed on the m2000sp instrument where RNA is isolated using magnetic microparticle technology and dispensed to a PCR tray together with the amplification reagents. The PCR tray is then transferred to the Abbott m2000rt instrument for amplification and real-time detection. The assay utilizes two distinct sets of primers and probes for HIV-1 and for internal control (IC). The IC is processed along with each sample to control for sample recovery and inhibition. The HIV-1 primer and probe sequences are targeted to the integrase (IN) region of the polymerase (pol) gene. Due to the selection of a highly conserved target region and a novel, mismatch tolerant probe design, the assay can quantitate HIV-1 group M subtypes A-H, group O, and group N isolates. The assay provides high reproducibility and a wide dynamic range, allowing quantitation from 40 copies to 10 million copies of HIV-1 RNA per milliliter of plasma. HIV-1 RNA concentrations detected with 95% probability were 25copies/mL with 1.0mL of plasma, 39copies/mL with 0.6mL of plasma, 65copies/mL with 0.5mL of plasma, and 119copies/mL with 0.2mL of plasma.
Collapse
|
5
|
Clinical comparison of branched DNA and reverse transcriptase-PCR and nucleic acid sequence-based amplification assay for the quantitation of circulating recombinant form_BC HIV-1 RNA in plasma. AIDS 2007; 21 Suppl 8:S27-32. [PMID: 18172387 DOI: 10.1097/01.aids.0000304693.16767.66] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/26/2022]
Abstract
OBJECTIVE To investigate the correlation between three viral load assays for circulating recombinant form (CRF)_BC. DESIGN Recent studies in HIV-1 molecular epidemiology, reveals that CRF_BC is the dominant subtype of HIV-1 virus in mainland China, representing over 45% of the HIV-1 infected population. The performances of nucleic acid sequence-based amplification (NASBA), branched DNA (bDNA) and reverse transcriptase polymerase chain reaction (RT-PCR) were compared for the HIV-1 viral load detection and quantitation of CRF_BC in China. METHODS Sixteen HIV-1 positive and three HIV-1 negative samples were collected. Sequencing of the positive samples in the gp41 region was conducted. The HIV-1 viral load values were determined using bDNA, RT-PCR and NASBA assays. Deming regression analysis with SPSS 12.0 (SPS Inc., Chicago, Illinois, USA) was performed for data analysis. RESULTS Sequencing and phylogenetic analysis of env gene (gp41) region of the 16 HIV-1 positive clinical specimens from Guizhou Province in southwest China revealed the dominance of the subtype CRF_BC in that region. A good correlation of their viral load values was observed among three assays. Pearson's correlation between RT-PCR and bDNA is 0.969, Lg(VL)RT-PCR = 0.969 * Lg(VL)bDNA + 0.55; Pearson's correlation between RT-PCR and NASBA is 0.968, Lg(VL)RT-PCR = 0.968 * Lg(VL)NASBA + 0.937; Pearson's correlation between NASBA and bDNA is 0.980, Lg(VL)NASBA = 0.980 * Lg(VL)bDNA - 0.318. CONCLUSION When testing with 3 different assays, RT-PCR, bDNA and NASBA, the group of 16 HIV-1 positive samples showed the viral load value was highest for RT-PCR, followed by bDNA then NASBA, which is consistent with the former results in subtype B. The three viral load assays are highly correlative for CRF_BC in China.
Collapse
|
6
|
Baseline resistance to nucleoside reverse transcriptase inhibitors fails to predict virologic response to combination therapy in children (PACTG 338). AIDS Res Ther 2007; 4:2. [PMID: 17280617 PMCID: PMC1802955 DOI: 10.1186/1742-6405-4-2] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/09/2006] [Accepted: 02/06/2007] [Indexed: 11/22/2022] Open
Abstract
Background The association between baseline drug resistance mutations and subsequent increase in viral failure has not been established for HIV-infected children. We evaluated drug resistance mutations at 39 codon sites (21 protease inhibitor (PI) resistant codons and 18 nucleoside reverse transcriptase inhibitor (NRTI) resistant codons) for 92 clinically stable NRTI-experienced, PI-naive HIV-infected children 2 to 17 years of age who were initiating new therapy with ritonavir plus zidovudine (ZDV) and lamivudine or plus stavudine. The association between baseline drug resistance mutations and subsequent viral failure after 12 and 24 weeks of highly active antiretroviral therapy (HAART) was studied. Results There were few primary PI associated mutations in this PI-naïve population, but 84% had NRTI mutations – codons 215 (66%), 41 (42%), 67 (37%), 210 (33%) and 70 (32%). None of the specific baseline drug resistance mutations were associated with a higher rate of virologic failure after 12 or 24 weeks of HAART. Median week 12 viral load decreased as the total number of NRTI mutations at baseline increased (P = 0.006). Specifically, a higher level of baseline ZDV resistance mutation was associated with a decrease in viral failure after 12 weeks on a ZDV-containing HAART regimen (P = 0.017). Conclusion No increase was seen in the rate of viral failure after HAART associated with the presence of resistance mutations at baseline. This paradoxical result may be due to adherence, replicative capacity, or ZDV hypersusceptibility to the new regimen.
Collapse
|
7
|
Evaluation of NucliSens EasyQ™ HIV-1 assay for quantification of HIV-1 subtypes prevalent in South-east Asia. J Clin Virol 2007; 38:39-43. [PMID: 17110162 DOI: 10.1016/j.jcv.2006.10.002] [Citation(s) in RCA: 10] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/24/2006] [Revised: 10/06/2006] [Accepted: 10/06/2006] [Indexed: 11/15/2022]
Abstract
BACKGROUND Monitoring anti-retroviral therapy requires that viral load assays for human immunodeficiency virus type 1 (HIV-1) be applicable to diverse HIV-1 subtypes. OBJECTIVES To evaluate NucliSens EasyQ HIV-1 assay for quantitation of common HIV-1 subtypes prevalent in South-east Asia. STUDY DESIGN One hundred and nineteen plasma samples collected in Hong Kong and Cambodia were used to compare the performance of NucliSens EasyQ HIV-1 and COBAS Amplicor HIV-1 Monitor version 1.5 assays. Viral RNA extracted from the NucliSens MiniMAG was also used for HIV-1 subtyping. RESULTS Performance of NucliSens EasyQ correlated well with COBAS Amplicor (r=0.777, p<0.001) and the small mean difference (0.0462log(10)IU/mL) obtained in the Bland and Altman model indicated good agreement between two assays. The NucliSens EasyQ assay demonstrated a 95% sensitivity at 500IU/mL and 100% specificity. Reproducibility of this assay was within log(10)2-4IU/mL and had a coefficient of variation between 2.3% and 10.4%. Among the 109 specimens included in the analysis, HIV-1 subtyping identified 64 CRF01_AE, 38 subtype B, 3 subtype C, 3 CRF07_BC and 1 subtype G viruses. CONCLUSIONS Performance of NucliSens EasyQ was comparable to COBAS Amplicor for HIV-1 viral load monitoring. RNA extracts from NucliSens MiniMAG could be used for HIV-1 viral load monitoring, subtyping and drug resistance mutations detection. Our findings highlight the versatility of both NucliSens EasyQ and COBAS Amplicor in monitoring prevalent subtypes and rare circulating recombinant forms (CRFs) in the South-east Asia region.
Collapse
|
8
|
Abstract
The authors discuss studies on the low-cost viral load assays that are currently available and their potential for use in resource-limited settings.
Collapse
|
9
|
Performance of the automated Abbott RealTime HIV-1 assay on a genetically diverse panel of specimens from Brazil. J Virol Methods 2006; 134:237-43. [PMID: 16510195 DOI: 10.1016/j.jviromet.2006.01.012] [Citation(s) in RCA: 36] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/18/2005] [Revised: 01/11/2006] [Accepted: 01/17/2006] [Indexed: 12/29/2022]
Abstract
The combination of automated sample preparation and real-time RT-PCR for measurement of HIV-1 viral load has the potential to significantly enhance throughput, reduce operator-associated error, and increase assay sensitivity and dynamic range. In this study, RNA was extracted from the plasma of 91 HIV-1 seropositive Brazilian blood donors using the Abbott m2000sp automated sample preparation system. Viral loads measured using the RealTime HIV-1 (RealTime HIV-1) assay and the Abbott m2000rt instrument were compared to values obtained in the LCx HIV RNA quantitative assay. Subtype was determined for 89 of 91 specimens by sequence/phylogenetic analysis of three genomic regions: gag p24, pol integrase, and env gp41. The panel included 69 subtype B, 1 C, 2 F, and 17 recombinant strains. Eighty-seven specimens were quantified by both assays. Two specimens were quantified only in RealTime HIV-1. Two additional specimens below the detection limit of both assays were also negative on PCR amplification. Viral load results were highly correlated, and good agreement was observed between assays with 90% of values within 0.5 log(10)copies/ml. The RealTime HIV-1 assay and m2000 system offer the advantages of automation while providing reliable quantification of diverse HIV strains.
Collapse
|
10
|
Abstract
From the recent and emerging concerns for approving lentiviral vector-mediated gene transfer in human clinical applications, several analytical methods have been applied in preclinical models to address the lentiviral vector load in batches, cells or tissues. This review points out the oldest generation methods (blots, RT activity, standard PCR) as well as a full description of the newest real-time quantitative PCR (qPCR) applications. Combinations of primer and probe sequences, which have worked in the lentiviral amplification context, have been included in the effort to dress an exhaustive list. Also, great variations have been observed from interlaboratory results, we have tempted to compare between them the different analytical methods that have been used to consider (i) the titration of lentiviral vector batches, (ii) the absence of the susceptible emerging replicative lentiviruses or (iii) the lentiviral vector biodistribution in the organism.
Collapse
|
11
|
Impact of human immunodeficiency virus type 1 (HIV-1) genetic diversity on performance of four commercial viral load assays: LCx HIV RNA Quantitative, AMPLICOR HIV-1 MONITOR v1.5, VERSANT HIV-1 RNA 3.0, and NucliSens HIV-1 QT. J Clin Microbiol 2005; 43:3860-8. [PMID: 16081923 PMCID: PMC1233972 DOI: 10.1128/jcm.43.8.3860-3868.2005] [Citation(s) in RCA: 86] [Impact Index Per Article: 4.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/11/2004] [Revised: 04/22/2005] [Accepted: 05/06/2005] [Indexed: 11/20/2022] Open
Abstract
Human immunodeficiency virus type 1 (HIV-1) evolution and changing strain distribution present a challenge to nucleic acid-based assays. Reliable patient monitoring of viral loads requires the detection and accurate quantification of genetically diverse HIV-1. A panel of 97 HIV-1-seropositive plasma samples collected from Cameroon, Brazil, and South Africa was used to compare the performance of four commercially available HIV RNA quantitative tests: Abbott LCx HIV RNA Quantitative assay (LCx), Bayer Versant HIV-1 RNA 3.0 (bDNA), Roche AMPLICOR HIV-1 MONITOR v1.5 (Monitor v1.5), and bioMérieux NucliSens HIV-1 QT (NucliSens). The panel included group M, group O, and recombinant viruses based on sequence analysis of gag p24, pol integrase, and env gp41. The LCx HIV assay quantified viral RNA in 97 (100%) of the samples. In comparison, bDNA, Monitor v1.5, and NucliSens quantified viral RNA in 96.9%, 94.8%, and 88.6% of the samples, respectively. The two group O specimens were quantified only by the LCx HIV assay. Analysis of nucleotide mismatches at the primer/probe binding sites for Monitor v1.5, NucliSens, and LCx assays revealed that performance characteristics reflected differences in the level of genetic conservation within the target regions.
Collapse
|
12
|
High Correlation of Human Immunodeficiency Virus Type-1 Viral Load Measured in Dried-Blood Spot Samples and in Plasma under Different Storage Conditions. Arch Med Res 2005; 36:382-6. [PMID: 15950079 DOI: 10.1016/j.arcmed.2005.03.010] [Citation(s) in RCA: 67] [Impact Index Per Article: 3.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/13/2004] [Accepted: 12/22/2004] [Indexed: 11/19/2022]
Abstract
BACKGROUND To measure HIV-1 RNA concentration requires venous extraction of blood, use of RNAase-free materials, and transport in a cold chain, which makes difficult the management of samples in developing countries. We evaluated the utility of the determination of HIV-1 RNA concentration in blood samples dried on filter paper (DBS) and subjected to different conditions, as contrasted with determination in plasma. METHODS HIV-1 RNA concentration was determined in HIV-infected patients in DBS and in plasma samples. Samples were subjected to the following: DBS were stored at 4, 22, and 37 degrees C for 1, 3, and 7 days; samples from patients from four regions of Mexico were mailed to a reference laboratory; DBS were sent under environmental conditions; and plasma samples were sent frozen. HIV-1 RNA concentrations were determined by NucliSens in DBS and by Amplicor test in plasma. RESULTS HIV-1 RNA concentration determined in DBS subjected to different temperatures and times had a significant correlation (r=0.99) with those obtained in plasma. When compared with values in plasma, Kappa agreement coefficients of values in DBS stored for 7 days at 4, 22, and 37 degrees C were 0.98, 0.83, and 0.94, respectively. Quantification of HIV-1 RNA in 108 DBS mailed from remote areas with different climates demonstrated significant correlation with those obtained in plasma (r=0.95; p <0.001). CONCLUSIONS DBS is a simple and reliable method to measure HIV-1 RNA concentration, especially when samples are mailed from remote areas to a reference center. This collection method is an economic and suitable alternative for use in developing countries.
Collapse
|
13
|
Switch from Ritonavir to Indinavir in Combination Therapy for HIV‐1–Infected Children. Clin Infect Dis 2005; 40:1181-7. [PMID: 15791520 DOI: 10.1086/428833] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/14/2004] [Accepted: 12/03/2004] [Indexed: 11/03/2022] Open
Abstract
BACKGROUND Protease inhibitors are an effective component of combination antiretroviral treatment for children infected with human immunodeficiency virus 1 (HIV-1), but tolerance or toxicity issues sometimes require an alternative therapeutic strategy. METHODS HIV-1-infected children aged 2-17 years received combination therapy with either stavudine plus ritonavir or with zidovudine, lamivudine, and ritonavir as part of a randomized clinical trial. Twenty-one months after the start of the trial, ritonavir in capsule formulation became unavailable. The treatment regimen for 25 children was switched from ritonavir capsules to indinavir capsules (500 mg/m(2) every 8 h). The other study drugs remained unchanged. A matched-pairs analysis was performed to compare the results for these 25 children with the results for 25 matched children whose treatment regimen continued to include ritonavir (in liquid formulation). RESULTS There were no significant differences in the percentage of children with an HIV-1 RNA load of <or=200 copies/mL between the group receiving indinavir and the matched group receiving ritonavir (52% vs. 68%, at the start of indinavir treatment; 42% vs. 52%, at week 12; and 50% vs. 56%, at week 24). Similarly, there were no significant differences between the treatment groups with respect to median CD4 cell counts over time. Toxicities observed in the children treated with indinavir were most often flank pain or headache (16%), renal dysfunction (16%), hematuria (12%), and skin rash (12%) and were consistent with toxicities reported elsewhere. There was no evidence that the switch from ritonavir to indinavir therapy altered the pharmacokinetics of indinavir as a result of residual cytochrome P450 induction or inhibition caused by ritonavir. CONCLUSIONS The switch from one protease inhibitor (ritonavir) to another (indinavir) as a component of combination antiretroviral treatment in this patient population was a practical therapeutic strategy.
Collapse
|
14
|
HIV-1 populations in blood and breast milk are similar. Virology 2005; 330:295-303. [PMID: 15527854 DOI: 10.1016/j.virol.2004.09.004] [Citation(s) in RCA: 26] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/18/2004] [Revised: 08/19/2004] [Accepted: 09/08/2004] [Indexed: 10/26/2022]
Abstract
Mother-to-child transmission (MTCT) of human immunodeficiency virus type 1 (HIV-1) through breast milk is a significant mechanism of infection in many regions of the world. We compared the HIV-1 populations in paired blood and breast milk samples using a heteroduplex tracking assay (HTA) for the V1/V2 regions of env (V1/V2-HTA). V1/V2-HTA patterns were similar in the eight pairs of samples for which adequate template sampling could be demonstrated. No unique variants existed in either compartment, and differences detected in the relative abundance of variants between compartments were small, occurred among low abundance variants, and were not statistically significant. We also documented the impact of template sampling as a limiting feature in comparing two viral populations. The absence of unique variants and the lack of significant differences in the relative abundance of variants between these compartments support the conclusion that viruses in the blood plasma and breast milk are well equilibrated.
Collapse
|
15
|
Evaluation of the NucliSens EasyQ assay in HIV-1-infected individuals in South Africa. J Virol Methods 2004; 124:105-10. [PMID: 15664057 DOI: 10.1016/j.jviromet.2004.11.009] [Citation(s) in RCA: 33] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/19/2004] [Revised: 11/09/2004] [Accepted: 11/10/2004] [Indexed: 10/26/2022]
Abstract
We compared the performance of the NucliSens EasyQ assay (bioMerieux) combined with the manual NucliSens miniMag extraction methodology to the Roche Cobas Ampliprep/Standard Amplicor Monitor methodology (Roche Diagnostics) for HIV-1 RNA quantitation in HIV-1-infected individuals in South Africa. Plasma samples (284) from HIV sero-positive patients at different stages of infection were analyzed. The distribution of results was typical of the clinical samples received at the laboratory where 20% have viral load results <400 copies/ml (2.6 log) and 18% have viral load results >750000 copies/ml (5.8 log) using the Roche Amplicor Monitor standard assay. All statistical analyses were performed using log10-transformed values for all the variables in the analyses, i.e. log10EasyQIU/ml, and log10RNA (log10 copies/ml, Amplicor). Roche values were converted from RNA copies per ml to IU/ml by multiplying the Roche value by 0.51. HIV RNA levels quantitated by the NucliSens EasyQ assay correlated significantly with those of the Roche Cobas Amplicor Monitor assay (r=0.874, p<0.0001). Reproducibility of the NucliSens EasyQ assay in the log6IU range yielded CV variance of 1.3-2.84% for two well-trained technologists. In addition, a retrospective evaluation of the performance of the NucliSens EasyQ assay in 102 runs (2448) samples was conducted in the laboratory over a 4-month interval. Factors considered during this evaluation included time taken to perform the assay, volume requirements, number of required repeats, potential for contamination.
Collapse
|
16
|
Abstract
The agreement of the microwell plate AMPLICOR HIV-1 MONITOR version 1.0 (MWP 1.0), the microwell plate AMPLICOR HIV-1 MONITOR version 1.5 (MWP 1.5), and the COBAS AMPLICOR HIV-1 MONITOR version 1.5 (COBAS 1.5) tests was evaluated using clinical specimens and well-characterized control material. Two hundred patient plasma specimens and a panel of known human immunodeficiency virus type 1 (HIV-1) subtypes were tested. All data were log(10) transformed prior to analysis. The 95% limits of agreement for the three tests at the average of 3.66 log(10) copies/ml were +/- 0.28 log(10), +/- 0.34 log(10), and +/- 0.34 log(10) copies/ml for MWP 1.0-MWP 1.5, MWP 1.0-COBAS 1.5, and MWP 1.5-COBAS 1.5, respectively. Ten specimens (6.1%) had differences exceeding the limits of agreement for the MWP 1.0 and MWP 1.5 tests. Correlation coefficients among the three tests were high (r >or=0.96). The viral-load values obtained with the MWP 1.0 test were only 2.1% higher on average than those measured with the MWP 1.5 test and 1.6% higher than those seen with the COBAS 1.5 test. The MWP 1.5 test values were 0.8% higher than the COBAS 1.5 test values. Overall, there was less agreement among the different tests for viral-load values near the lower limit of quantification. The MWP 1.0 test underquantified subtypes A, E, F, G, and H by 1.0 to 2.0 log(10) copies/ml; this problem was not observed with the MWP 1.5 test. The close agreement among the results obtained with the different test versions and formats suggests that it is not necessary to reestablish a baseline viral load when changing AMPLICOR HIV-1 MONITOR tests, unless the patient is known to be infected with a non-B subtype.
Collapse
|
17
|
Abstract
Norwalk-like viruses (NLVs) are a genetically diverse group of human caliciviruses that are the most common cause of epidemic gastroenteritis and are detected typically in stool by reverse transcription (RT)-PCR or electron microscopy (EM). The application of a rapid nucleic acid sequence-based amplification (NASBA) assay for the detection of NLV RNA in stool is described using the NucliSens Basic Kit. Primers and probes for the NLV Basic Kit assay were based on the RNA polymerase region of the prototype NLV, Norwalk virus (NV) genome and could consistently detect 10(4) RT-PCR detectable units of NV RNA in a stool filtrate. When compared directly with RT-PCR on a dilution series of NV stool filtrate, the NucliSens Basic Kit assay was equally sensitive. Cross-reactivity studies with a representative panel of other enteric pathogens were negative. When applied to 15 stool specimens from NV-challenged volunteers, the NASBA Basic Kit application for NV detection yielded 100% sensitivity, 50% specificity, and 67% concordance, using RT-PCR as the 'gold standard'. Despite the specificity of the NASBA primer/probe sequences for NV, other representatives from both NLV genogroups I and II could be detected by the Basic Kit assay in outbreak stool specimens, although the results were inconsistent. Our results suggest that the NucliSens Basic Kit assay provides a rapid and sensitive alternative to RT-PCR for detecting NV RNA in stool specimens. However, improvements in test specificity and primer design will be needed before the assay can be used routinely in the clinical setting.
Collapse
|
18
|
Principles of quantitation of viral loads using nucleic acid sequence-based amplification in combination with homogeneous detection using molecular beacons. Nucleic Acids Res 2002; 30:e26. [PMID: 11884645 PMCID: PMC101370 DOI: 10.1093/nar/30.6.e26] [Citation(s) in RCA: 50] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/13/2022] Open
Abstract
For quantitative NASBA-based viral load assays using homogeneous detection with molecular beacons, such as the NucliSens EasyQ HIV-1 assay, a quantitation algorithm is required. During the amplification process there is a constant growth in the concentration of amplicons to which the beacon can bind while generating a fluorescence signal. The overall fluorescence curve contains kinetic information on both amplicon formation and beacon binding, but only the former is relevant for quantitation. In the current paper, mathematical modeling of the relevant processes is used to develop an equation describing the fluorescence curve as a function of the amplification time and the relevant kinetic parameters. This equation allows reconstruction of RNA formation, which is characterized by an exponential increase in concentrations as long as the primer concentrations are not rate limiting and by linear growth over time after the primer pool is depleted. During the linear growth phase, the actual quantitation is based on assessing the amplicon formation rate from the viral RNA relative to that from a fixed amount of calibrator RNA. The quantitation procedure has been successfully applied in the NucliSens EasyQ HIV-1 assay.
Collapse
|
19
|
Stavudine, nevirapine and ritonavir in stable antiretroviral therapy-experienced children with human immunodeficiency virus infection. Pediatr Infect Dis J 2002; 21:119-25. [PMID: 11840078 DOI: 10.1097/00006454-200202000-00007] [Citation(s) in RCA: 10] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/26/2022]
Abstract
BACKGROUND The efficacy and tolerance of switching from zidovudine (ZDV) and lamivudine (3TC) in clinically stable HIV-infected children with incomplete viral suppression to stavudine (d4T), nevirapine (NVP) and ritonavir (RTV) has not been determined. Aim. To evaluate the safety, tolerance, antiviral activity and immunologic changes after the change to a three drug combination. METHODS During a clinical trial in which HIV-infected antiretroviral-experienced children were initially randomized to receive d4T/RTV, ZDV/3TC/RTV or ZDV/3TC (Step 1), 48 children who had HIV RNA > or = 10,000 copies/ml after > or = 12 weeks of ZDV/3TC therapy in Step 1 were switched to d4T/NVP/RTV in Step 2. The proportion of children receiving therapy with HIV RNA < or = 400 copies/ml at Study Weeks 24 and 48 receiving d4T/NVP/RTV in Step 2 were compared with children receiving RTV-containing regimens in Step 1. RESULTS At 24 weeks of treatment with d4T/NVP/RTV in Step 2, 48% (23 of 48) of children had HIV RNA < or = 400 copies/ml compared with 34% (31 of 92) and 47% (44 of 93) receiving d4T/RTV or ZDV/3TC/RTV for 24 weeks in Step 1; at 48 weeks virologic response was 44, 27 and 42% in Step 2 d4T/NVP/RTV, Step 1 d4T/RTV and Step 1 ZDV/3TC/RTV arms, respectively. CONCLUSIONS A delay of 7 to 12 months in the initiation of protease inhibitor-containing combination therapy in children receiving dual nucleoside analogue therapy did not adversely affect the RNA response during the first 48 weeks of treatment.
Collapse
|
20
|
Multicenter Study of the LCx® HIV RNA Quantitative Assay – a New Competitive Reverse Transcriptase-PCR which Targets pol Genomic Region of HIV-1 for the Measurement of Type B, Non-Type B and Group O HIV-1 RNA. Clin Chem Lab Med 2002; 40:698-704. [PMID: 12241017 DOI: 10.1515/cclm.2002.120] [Citation(s) in RCA: 11] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/15/2022]
Abstract
Performance characteristics of the Abbott LCx HIV RNA Quantitative Assay (LCx HIV) were established in a multicenter study comparing it with the manual (Amplicor v1.5) and automated (Cobas) ultra-sensitive Roche Amplicor HIV-1 Monitor v1.5, the Bayer Quantiplex HIV RNA 3.0 (bDNA v3.0), and the Organon NucliSens HIV QT 2.0 (NucliSens). Within-run precision of LCx HIV assessed in clinical specimens was SD log10 0.210 at approximately 50 copies/ml, and log10 0.133 at approximately 400 copies/ml. Total precision in a reconstituted type B HIV-1 RNA panel was SD log10 0.380 at 100 copies/ml, and SD log10 0.180 at 1000 copies/ml. Type B HIV-1 RNA sensitivity (1 ml input) assessed at a 50%, 75% and 95% detection rate ranged from 29 to 41, 54 to 75 and 94 to 176 copies/ml, respectively. Overall specificity in HIV seronegative individuals was 99.78%. Linear regression indicated close assay correlations and agreements for measurement of type B HIV-1 RNA. Pearson's correlations and (Log10LCx=aLog10x + b) linear regressions were 0.91 (y=0.892 Log10Amplicor + 0.595), 0.93 (y=0.827 Log10Cobas + 0.969), 0.93 (y=0.951 Log10bDNA + 0.550), and 0.79 (y=0.834 Log10NucliSens + 0.911). LCx HIV was least affected by the genetic variability of HIV-1. LCx HIV detected 99% of non-type B HIV-1 group M samples (subtypes A-G), Amplicor v1.5 detected 96%, and bDNA v3.0 detected 99%. The assays detected 10/11, 1/11 and 8/11, respectively of the HIV-1 group O samples. LCx HIV vs. Amplicor/bDNA Spearman's rank correlations for quantification of non-type B HIV-1 RNA were 0.76/0.84 (A), 0.93/0.93 (C), 0.73/0.99 (D), 0.86/0.98 (E), and 0.40/0.83 (group O). LCx HIV assays consistently detect and quantify type B, non-type B and group O HIV-1 RNA.
Collapse
|
21
|
Comparison of Roche MONITOR and Organon Teknika NucliSens assays to quantify human immunodeficiency virus type 1 RNA in cerebrospinal fluid. J Clin Microbiol 2001; 39:1612-4. [PMID: 11283098 PMCID: PMC87981 DOI: 10.1128/jcm.39.4.1612-1614.2001] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/20/2022] Open
Abstract
We compared Roche MONITOR and Organon Teknika NucliSens assays for human immunodeficiency virus type 1 (HIV-1) RNA in cerebrospinal fluid (CSF). Results of 282 assays were highly correlated (r = 0.826), with MONITOR values being 0.29 +/- 0.4 log(10) copies/ml (mean +/- standard deviation) values. Both assays can reliably quantify HIV-1 RNA in CSF.
Collapse
|
22
|
Prenatal transmission of subtype C HIV-1 in Zimbabwe: HIV-1 RNA and DNA in maternal and cord blood. J Acquir Immune Defic Syndr 2000; 25:390-7. [PMID: 11141238 DOI: 10.1097/00042560-200012150-00002] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/25/2022]
Abstract
Maternal and cord samples from HIV-seropositive women and their infants in Zimbabwe, where subtype C is the predominant strain of HIV, were analyzed to determine the frequency of detection of HIV RNA and DNA. HIV RNA was detected in 90% of maternal and in 38% of cord plasma at levels at least 25% of maternal plasma. Heteroduplex mobility assays and sequencing of virus envelope (C2-V5) demonstrated closely related, but unique, subtype C viruses in maternal and cord RNA, and a significantly greater frequency of cord viremia among women with homogenous, compared with heterogeneous viral envelope RNA. Quantification of RNA, measures of envelope viral diversity, and phylogenetic analysis of maternal and cord plasma RNA provide evidence for the frequent exposure and potential transmission of HIV from mother to infant before birth.
Collapse
|
23
|
Prenatal Transmission of Subtype C HIV-1 in Zimbabwe: HIV-1 RNA and DNA in Maternal and Cord Blood. J Acquir Immune Defic Syndr 2000. [DOI: 10.1097/00126334-200012150-00002] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/25/2022]
|
24
|
Multicenter comparison of Roche COBAS AMPLICOR MONITOR version 1.5, Organon Teknika NucliSens QT with Extractor, and Bayer Quantiplex version 3.0 for quantification of human immunodeficiency virus type 1 RNA in plasma. J Clin Microbiol 2000; 38:4034-41. [PMID: 11060065 PMCID: PMC87538 DOI: 10.1128/jcm.38.11.4034-4041.2000] [Citation(s) in RCA: 77] [Impact Index Per Article: 3.2] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/20/2022] Open
Abstract
The performance and characteristics of Roche COBAS AMPLICOR HIV-1 MONITOR version 1.5 (CA MONITOR 1.5) UltraSensitive (usCA MONITOR 1. 5) and Standard (stCA MONITOR 1.5) procedures, Organon Teknika NucliSens HIV-1 RNA QT with Extractor (NucliSens), and Bayer Quantiplex HIV RNA version 3.0 (bDNA 3.0) were compared in a multicenter trial. Samples used in this study included 460 plasma specimens from human immunodeficiency virus (HIV) type 1 (HIV-1)-infected persons, 100 plasma specimens from HIV antibody (anti-HIV)-negative persons, and culture supernatants of HIV-1 subtype A to E isolates diluted in anti-HIV-negative plasma. Overall, bDNA 3.0 showed the least variation in RNA measures upon repeat testing. For the Roche assays, usCA MONITOR 1.5 displayed less variation in RNA measures than stCA MONITOR 1.5. NucliSens, at an input volume of 2 ml, showed the best sensitivity. Deming regression analysis indicated that the results of all three assays were significantly correlated (P < 0.0001). However, the mean difference in values between CA MONITOR 1.5 and bDNA 3.0 (0.274 log(10) RNA copies/ml; 95% confidence interval, 0.192 to 0.356) was significantly different from 0, indicating that CA MONITOR 1.5 values were regularly higher than bDNA 3.0 values. Upon testing of 100 anti-HIV-negative plasma specimens, usCA MONITOR 1.5 and NucliSens displayed 100% specificity, while bDNA 3.0 showed 98% specificity. NucliSens quantified 2 of 10 non-subtype B viral isolates at 1 log(10) lower than both CA MONITOR 1.5 and bDNA 3.0. For NucliSens, testing of specimens with greater than 1,000 RNA copies/ml at input volumes of 0.1, 0.2, and 2.0 ml did not affect the quality of results. Additional factors differing between assays included specimen throughput and volume requirements, limit of detection, ease of execution, instrument work space, and costs of disposal. These characteristics, along with assay performance, should be considered when one is selecting a viral load assay.
Collapse
|
25
|
Evaluation of a second-generation nucleic acid sequence-based amplification assay for quantification of HIV type 1 RNA and the use of ultrasensitive protocol adaptations. AIDS Res Hum Retroviruses 2000; 16:1507-17. [PMID: 11054264 DOI: 10.1089/088922200750006038] [Citation(s) in RCA: 14] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/12/2022] Open
Abstract
Accurate assessment of plasma HIV RNA levels at low concentrations is clinically important. We evaluated a second-generation quantitative HIV RNA assay (NucliSens HIV-1 QT), and three simple adaptations of the NucliSens standard protocol to lower the lower cutoff level. The assays were evaluated in constructed panels with known HIV RNA concentrations and in clinical samples. Results were compared with those obtained with the first generation (NASBA HIV-1 QT) and with two other commercially available assays: the Amplicor HIV Monitor test and the Quantiplex assay. In a constructed panel, results obtained by NASBA QT were on average 0.13 log(10) copies/ml (SD 0.15) higher than those of NucliSens. The NucliSens assay could quantify HIV RNA in at least 50% of the samples down to 518 (2.71 log(10)) copies/ml and NASBA QT to 5.80 x 10(3) (3.76 log(10)) copies/ml). Both assays correlated well with the known input (R NucliSens = 0.99; R NASBA QT = 0.996), but results were more variable at lower input levels. With the three different ultrasensitive NucliSens adaptations, HIV RNA could be quantified in at least 50% of the samples down to 100 (2.00 log(10)), 46 (1.66 log(10)), and 10 (1.00 log(10)) copies/ml, respectively. In patient samples, Amplicor results were on average 0.11 (SD 0.20) log(10) copies/ml above, NucliSens 0.02 (SD 0.29) copies/ml above, and Quantiplex 0.13 (SD 0.19) copies/ml below the mean of the three assay results per sample. The variation remained the same over the range of RNA levels with all three assays. The NucliSens assay can quantify HIV RNA at lower levels than the NASBA QT and is comparable to other commercially available assays. The lower cutoff of the NucliSens can be lowered down to 10 copies/ml.
Collapse
|
26
|
Evaluation of the abbott LCx HIV-1 RNA quantitative, a new assay for quantitative determination of human immunodeficiency virus type 1 RNA. J Clin Microbiol 2000; 38:3882-6. [PMID: 11015428 PMCID: PMC87501 DOI: 10.1128/jcm.38.10.3882-3886.2000] [Citation(s) in RCA: 12] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/20/2022] Open
Abstract
A new quantitative reverse transcription (RT)-PCR assay for human immunodeficiency virus type 1 (HIV-1) RNA (Abbott LCx HIV RNA Quantitative assay) has been compared with the Organon NucliSens assay on 521 retrospective samples obtained from HIV-1-positive patients monitored during highly active antiretroviral therapy, 79 of whom were assayed also by the Chiron Quantiplex 3.0 system and on characterized panels. The LCx system showed a moderate correlation (r = 0.795) and gave higher results than the NucliSens system on 245 of 327 concordant positive samples, with similar sensitivity. Correlation with Quantiplex system results was higher (r = 0.943). LCx reproducibility was very good; the procedure was simple, well controlled, and rapid (up to 48 results in 7 h). The HIV RNA quantitative assay on the LCx system is suitable for routine use.
Collapse
|
27
|
Comparison of two amplification technologies for detection and quantitation of human immunodeficiency virus type 1 RNA in the female genital tract. Division of AIDS Treatment Research Initiative 009 Study Team. J Clin Microbiol 2000; 38:2665-9. [PMID: 10878061 PMCID: PMC86993 DOI: 10.1128/jcm.38.7.2665-2669.2000] [Citation(s) in RCA: 25] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/20/2022] Open
Abstract
Human immunodeficiency virus type 1 (HIV-1) RNA levels in female genital tract and peripheral blood samples were compared using two commercial amplification technologies: the Roche AMPLICOR HIV-1 MONITOR test and either the Organon Teknika nucleic acid sequence-based amplification (NASBA-QT) assay or the NucliSens assay. Estimates of HIV-1 RNA copy number were derived from internal kit standards and analyzed unadjusted and adjusted to a common set of external standards. We found a discordance rate of approximately 18% between the two technologies for the detection of HIV-1 in either the genital tract or peripheral blood samples. Detection discordance was not consistent among specimens or among women. There were no significant differences in adjusted or unadjusted estimates of HIV-1 RNA copy number in the genital tract samples using the AMPLICOR HIV-1 MONITOR test and either the NASBA-QT assay or the NucliSens assay. In addition, the estimated HIV-1 RNA copy number in peripheral blood samples did not differ when tested with the NucliSens assay and the AMPLICOR HIV-1 MONITOR test using kit standards. However, there was a significant difference in estimated RNA copy number between the NASBA-QT assay and the AMPLICOR HIV-1 MONITOR test for internal kit standards, which, as we have previously shown, was eliminated after adjustment with the external standards. Our results suggest that the Roche and Organon Teknika assays are equivalent for quantifying HIV-1 RNA in female genital tract specimens, although variation in detection does exist.
Collapse
|
28
|
Multicenter evaluation of methods to quantitate human immunodeficiency virus type 1 RNA in seminal plasma. J Clin Microbiol 2000; 38:2348-53. [PMID: 10835001 PMCID: PMC86800 DOI: 10.1128/jcm.38.6.2348-2353.2000] [Citation(s) in RCA: 20] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/20/2022] Open
Abstract
We have evaluated two commercially available kits (AMPLICOR MONITOR [Roche] and NASBA HIV-1 QT or NucliSens HIV-1 QT [Organon Teknika]) and two noncommercial methods for the accurate quantitation of human immunodeficiency virus type 1 (HIV-1) RNA in seminal plasma. The same panels of coded specimens were tested on four separate occasions. Laboratories using the commercial assays employed silica beads to isolate HIV-1 RNA, which removed inhibitory factors sometimes found in seminal plasma. Sensitivities and specificities, respectively, for each assay were as follows: AMPLICOR MONITOR, 100 and 73%; NASBA HIV-1 QT, 84 and 100%; NucliSens HIV-1 QT, 99 and 98%; and noncommercial assays, 91 and 73%. When results from the laboratory that was inexperienced with the silica bead extraction method were excluded from the analysis, specificity for the Roche assay increased to 100%. The commercial assays demonstrated highly reproducible results, with intra-assay standard deviations (measured in log(10) RNA copies/milliliter of seminal plasma) ranging from 0.11 to 0.32; those of the noncommercial assays ranged from 0.12 to 0.75. Differences in mean estimated HIV-1 RNA concentrations were </=0.67 log(10) and were greater at low viral loads. Suspension matrices that used blood plasma or seminal plasma did not make a difference in recovery of HIV-1 RNA, which suggested that blood plasma specimens can be used as external controls for seminal plasma assays. More variation in the HIV-1 RNA viral loads was observed in the seminal plasma values than in the blood plasma values when paired specimens from HIV-1-infected men were tested. Quantitation of HIV-1 RNA in seminal plasma can be reliably accomplished using two commercially available assays, and may be incorporated into the evaluations of HIV-1 seropositive men enrolled in clinical studies.
Collapse
|
29
|
Quantitation of human immunodeficiency virus type 1 RNA in different biological compartments. J Clin Microbiol 2000; 38:1414-8. [PMID: 10747117 PMCID: PMC86455 DOI: 10.1128/jcm.38.4.1414-1418.2000] [Citation(s) in RCA: 82] [Impact Index Per Article: 3.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/12/1999] [Accepted: 01/31/2000] [Indexed: 11/20/2022] Open
Abstract
Little information is available describing viral loads in body fluids other than blood. In addition, the suitability of commercially available assays for human immunodeficiency virus type 1 (HIV-1) RNA quantitation has not been evaluated in most nonblood fluids. We compared Organon Teknika's nucleic acid sequence-based amplification method (NASBA) and Roche's Amplicor HIV-1 Monitor (reverse transcriptase PCR [RT-PCR]) for quantitating HIV-1 RNA in cerebrospinal fluid (CSF), saliva, breast milk, seminal plasma, and cervical-vaginal lavage fluid (CVL). Saliva and breast milk frequently demonstrated some inhibition in the RT-PCR assay, similar to the inhibition previously described in seminal plasma. Inhibition of the RT-PCR assay was not observed with CSF or CVL, nor in any of the NASBA assays. When fluids from HIV-infected individuals were tested by RT-PCR and NASBA, 73 and 27% of CSF samples and 60 and 40% of breast milk specimens had detectable RNA, respectively. These differences were not statistically significant. In cross-sectional studies using RT-PCR to measure viral RNA in paired blood plasma and CSF samples, 71% of blood plasma samples and 42% of CSF samples were positive. A similar analysis using NASBA with paired blood plasma and CVL, saliva, or seminal plasma samples revealed 91% were blood plasma positive and 55% were CVL positive, 76% were blood plasma positive and 46% were saliva positive, and 83% were blood plasma positive and 63% were seminal plasma positive. NASBA worked fairly well to quantitate HIV-1 RNA from all fluids without apparent inhibition. RT-PCR performed well on CVL and CSF, frequently with greater sensitivity, although its use in other fluids appears limited due to the presence of inhibitors. These studies demonstrate that viral loads in nonblood fluids were generally lower than in blood.
Collapse
|
30
|
Obtaining unacceptable results in assays for quantitation of human immunodeficiency virus type 1 RNA in plasma samples. J Clin Microbiol 2000; 38:472-3. [PMID: 10681212 PMCID: PMC88760 DOI: 10.1128/jcm.38.1.472-473.2000] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/20/2022] Open
|
31
|
Effects of anticoagulant, processing delay, and assay method (branched DNA versus reverse transcriptase PCR) on measurement of human immunodeficiency virus type 1 RNA levels in plasma. J Clin Microbiol 1999; 37:2428-33. [PMID: 10405379 PMCID: PMC85245 DOI: 10.1128/jcm.37.8.2428-2433.1999] [Citation(s) in RCA: 23] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/25/1999] [Accepted: 04/29/1999] [Indexed: 11/20/2022] Open
Abstract
We conducted two studies to determine the potential influence of delays in blood processing, type of anticoagulant, and assay method on human immunodeficiency virus type 1 (HIV-1) RNA levels in plasma. The first was an experimental study in which heparin- and EDTA-anticoagulated blood samples were collected from 101 HIV-positive individuals and processed to plasma after delays of 2, 6, and 18 h. HIV-1 RNA levels in each sample were then measured by both branched-DNA (bDNA) and reverse transcriptase PCR (RT-PCR) assays. Compared to samples processed within 2 h, the loss (decay) of HIV-1 RNA in heparinized blood was significant (P < 0.05) but small after 6 h (bDNA assay, -0.12 log(10) copies/ml; RT-PCR, -0.05 log(10) copies/ml) and after 18 h (bDNA assay, -0.27 log(10) copies/ml; RT-PCR, -0.15 log(10) copies/ml). Decay in EDTA-anticoagulated blood was not significant after 6 h (bDNA assay, -0.002 log(10) copies/ml; RT-PCR, -0.02 log(10) copies/ml), but it was after 18 h (bDNA assay, -0.09 log(10) copies/ml; RT-PCR, -0.09 log(10) copies/ml). Only 4% of samples processed after 6 h lost more than 50% (>/=0.3 log(10) copies/ml) of the HIV-1 RNA, regardless of the anticoagulant or the assay that was used. The second study compared HIV-1 RNA levels in samples from the Multicenter AIDS Cohort Study (MACS; samples were collected in heparin-containing tubes in 1985, had a 6-h average processing delay, and were assayed by bDNA assay) and the British Columbia Drug Treatment Program (BCDTP) (collected in EDTA- or acid citrate dextrose-containing tubes in 1996 and 1997, had a 2-h maximum processing delay, and were assayed by RT-PCR). HIV-1 RNA levels in samples from the two cohorts were not significantly different after adjusting for CD4(+)-cell count and converting bDNA assay values to those corresponding to the RT-PCR results. In summary, the decay of HIV-1 RNA measured in heparinized blood after 6 h was small (-0.05 to -0.12 log(10) copies/ml), and the minor impact of this decay on HIV-1 RNA concentrations in archived plasma samples of the MACS was confirmed by the similarity of CD4(+)-cell counts and assay-adjusted HIV-1 RNA concentrations in the MACS and BCDTP.
Collapse
|