1
|
Böl M, Leichsenring K, Kohn S, Ehret AE. The anisotropic and region-dependent mechanical response of wrap-around tendons under tensile, compressive and combined multiaxial loads. Acta Biomater 2024:S1742-7061(24)00301-5. [PMID: 38838908 DOI: 10.1016/j.actbio.2024.05.053] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/01/2023] [Revised: 05/20/2024] [Accepted: 05/30/2024] [Indexed: 06/07/2024]
Abstract
The present work reports on the multiaxial region and orientation-dependent mechanical properties of two porcine wrap-around tendons under tensile, compressive and combined loads based on an extensive study with n=175 samples. The results provide a detailed dataset of the anisotropic tensile and compressive longitudinal properties and document a pronounced tension-compression asymmetry. Motivated by the physiological loading conditions of these tendons, which include transversal compression at bony abutments in addition to longitudinal tension, we systematically investigated the change in axial tension when the tendon is compressed transversally along one or both perpendicular directions. The results reveal that the transversal compression can increase axial tension (proximal-distal direction) in both cases to orders of 30%, yet by a larger amount in the first case (transversal compression in anterior-posterior direction), which seems to be more relevant for wrap-around tendons in-vivo. These quantitative measurements are in line with earlier findings on auxetic properties of tendon tissue, but show for the first time the influence of this property on the stress response of the tendon, and may thus reveal an important functional principle within these essential elements of force transmission in the body. STATEMENT OF SIGNIFICANCE: The work reports for the first time on multiaxial region and orientation-dependent mechanical properties of wrap-around tendons under various loads. The results indicate that differences in the mechanical properties exist between zones that are predominantly in a uniaxial tensile state and those that experience complex load states. The observed counterintuitive increase of the axial tension upon lateral compression points at auxetic properties of the tendon tissue which may be pivotal for the function of the tendon as an element of the musculoskeletal system. It suggests that the tendon's performance in transmitting forces is not diminished but enhanced when the action line is deflected by a bony pulley around which the tendon wraps, representing an important functional principle of tendon tissue.
Collapse
Affiliation(s)
- Markus Böl
- Institute of Mechanics and Adaptronics, Technische Universität Braunschweig, Braunschweig D-38106, Germany.
| | - Kay Leichsenring
- Institute of Mechanics and Adaptronics, Technische Universität Braunschweig, Braunschweig D-38106, Germany
| | - Stephan Kohn
- Institute of Mechanics and Adaptronics, Technische Universität Braunschweig, Braunschweig D-38106, Germany
| | - Alexander E Ehret
- Empa, Swiss Federal Laboratories for Materials Science and Technology, CH-8600 Dübendorf, Switzerland; Institute for Mechanical Systems, ETH Zurich, Zürich, CH-8092, Switzerland
| |
Collapse
|
2
|
Gomez-Florit M, Labrador-Rached CJ, Domingues RM, Gomes ME. The tendon microenvironment: Engineered in vitro models to study cellular crosstalk. Adv Drug Deliv Rev 2022; 185:114299. [PMID: 35436570 DOI: 10.1016/j.addr.2022.114299] [Citation(s) in RCA: 14] [Impact Index Per Article: 7.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/10/2021] [Revised: 04/11/2022] [Accepted: 04/12/2022] [Indexed: 12/12/2022]
Abstract
Tendinopathy is a multi-faceted pathology characterized by alterations in tendon microstructure, cellularity and collagen composition. Challenged by the possibility of regenerating pathological or ruptured tendons, the healing mechanisms of this tissue have been widely researched over the past decades. However, so far, most of the cellular players and processes influencing tendon repair remain unknown, which emphasizes the need for developing relevant in vitro models enabling to study the complex multicellular crosstalk occurring in tendon microenvironments. In this review, we critically discuss the insights on the interaction between tenocytes and the other tendon resident cells that have been devised through different types of existing in vitro models. Building on the generated knowledge, we stress the need for advanced models able to mimic the hierarchical architecture, cellularity and physiological signaling of tendon niche under dynamic culture conditions, along with the recreation of the integrated gradients of its tissue interfaces. In a forward-looking vision of the field, we discuss how the convergence of multiple bioengineering technologies can be leveraged as potential platforms to develop the next generation of relevant in vitro models that can contribute for a deeper fundamental knowledge to develop more effective treatments.
Collapse
|
3
|
Van Gulick L, Saby C, Jaisson S, Okwieka A, Gillery P, Dervin E, Morjani H, Beljebbar A. An integrated approach to investigate age-related modifications of morphological, mechanical and structural properties of type I collagen. Acta Biomater 2022; 137:64-78. [PMID: 34673231 DOI: 10.1016/j.actbio.2021.10.020] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/11/2021] [Revised: 10/08/2021] [Accepted: 10/12/2021] [Indexed: 11/24/2022]
Abstract
The main propose of this study is to characterize the impact of chronological aging on mechanical, structural, biochemical, and morphological properties of type I collagen. We have developed an original approach combining a stress-strain measurement device with a portable Raman spectrometer to enable simultaneous measurement of Raman spectra during stress vs strain responses of young adult, adult and old rat tail tendon fascicles (RTTFs). Our data showed an increase in all mechanical properties such as Young's modulus, yield strength, and ultimate tensile strength with aging. At the molecular level, Raman data revealed that the most relevant frequency shift was observed at 938 cm-1 in Old RTTFs, which is assigned to the C-C. This suggested a long axis deformation of the peptide chains in Old RTTFs during tensile stress. In addition, the intensity of the band at 872 cm-1, corresponding to hydroxyproline decreased for young adult RTTFs and increased for the adult ones, while it remained unchanged for Old RTTFs during tensile stress. The amide III band (1242 and 1265 cm-1) as well as the band ratios I1631/ I1663 and I1645 / I1663 responses to tensile stress were depending on mechanical phases (toe, elastic and plastic). The quantification of advanced glycation end-products by LC-MS/MS and spectrofluorometry showed an increase in their content with aging. This suggested that the accumulation of such products was correlated to the alterations observed in the mechanical and molecular properties of RTTFs. Analysis of the morphological properties of RTTFs by SHG combined with CT-FIRE software revealed an increase in length and straightness of collagen fibers, whereas their width and wavy fraction decreased. Our integrated study model could be useful to provide additional translational information to monitor progression of diseases related to collagen remodeling in musculoskeletal disorders. STATEMENT OF SIGNIFICANCE: Type I collagen is the major component of the extracellular matrix. Its architectural and structural organization plays an important role in the mechanical properties of many tissues at the physiological and pathological levels. The objective of this work is to develop an integrated approach to bring a new insight on the impact of chronological aging on the structural organization and mechanical properties of type I collagen. We combined a portable Raman spectrometer with a mechanical tensile testing device in order to monitor in real time the changes in the Raman fingerprint of type I collagen fibers during the mechanical stress. Raman spectroscopy allowed the identification of the type I collagen bonds that were affected by mechanical stress in a differential manner with aging.
Collapse
|
4
|
Al Makhzoomi AK, Kirk TB, Allison GT. A multiscale study of morphological changes in tendons following repeated cyclic loading. J Biomech 2021; 128:110790. [PMID: 34634539 DOI: 10.1016/j.jbiomech.2021.110790] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/05/2021] [Revised: 09/30/2021] [Accepted: 09/30/2021] [Indexed: 11/30/2022]
Abstract
The response of white New Zealand rabbit Achilles tendons to load was assessed using mechanical measures and confocal arthroscopy (CA). The progression of fatigue-loading-induced damage of the macro- (tenocyte morphology, fiber anisotropy and waviness), as well as the mechanical profile, were assessed within the same non-viable intact tendon in response to prolonged cyclic and static loading (up to four hours) at different strain levels (3%, 6% and 9%). Strain-mediated repeated loading induced a significant decline in mechanical function (p < 0.05) with increased strain and cycles. Mechanical and structural resilience was lost with repeated loading (p < 0.05) at macroscales. The lengthening of D-periodicity correlated strongly with the overall tendon mechanical changes and loss of spindle shape in tenocytes. This is the first study to provide a clear concurrent assessment of form (morphology) and function (mechanics) of tendons undergoing different strain-mediated repeated loading at multiple-scale assessments. This study identifies a variety of multiscale properties that may contribute to the understanding of mechanisms of tendon pathology.
Collapse
Affiliation(s)
- Anas K Al Makhzoomi
- School of Allied Health, Faculty of Health Science, Curtin University, Perth, Western Australia, Australia.
| | - Thomas B Kirk
- School of Science, Engineering and Technology, RMIT University Vietnam, Ho Chi Minh City, Vietnam
| | - Garry T Allison
- Research Office, Curtin University, Perth, Western Australia, Australia
| |
Collapse
|
5
|
Williamson PM, Freedman BR, Kwok N, Beeram I, Pennings J, Johnson J, Hamparian D, Cohen E, Galloway JL, Ramappa AJ, DeAngelis JP, Nazarian A. Tendinopathy and tendon material response to load: What we can learn from small animal studies. Acta Biomater 2021; 134:43-56. [PMID: 34325074 DOI: 10.1016/j.actbio.2021.07.046] [Citation(s) in RCA: 11] [Impact Index Per Article: 3.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/03/2021] [Revised: 07/16/2021] [Accepted: 07/21/2021] [Indexed: 12/20/2022]
Abstract
Tendinopathy is a debilitating disease that causes as much as 30% of all musculoskeletal consultations. Existing treatments for tendinopathy have variable efficacy, possibly due to incomplete characterization of the underlying pathophysiology. Mechanical load can have both beneficial and detrimental effects on tendon, as the overall tendon response depends on the degree, frequency, timing, and magnitude of the load. The clinical continuum model of tendinopathy offers insight into the late stages of tendinopathy, but it does not capture the subclinical tendinopathic changes that begin before pain or loss of function. Small animal models that use high tendon loading to mimic human tendinopathy may be able to fill this knowledge gap. The goal of this review is to summarize the insights from in-vivo animal studies of mechanically-induced tendinopathy and higher loading regimens into the mechanical, microstructural, and biological features that help characterize the continuum between normal tendon and tendinopathy. STATEMENT OF SIGNIFICANCE: This review summarizes the insights gained from in-vivo animal studies of mechanically-induced tendinopathy by evaluating the effect high loading regimens have on the mechanical, structural, and biological features of tendinopathy. A better understanding of the interplay between these realms could lead to improved patient management, especially in the presence of painful tendon.
Collapse
|
6
|
Wagner FC, Reese S, Gerlach K, Böttcher P, Mülling CKW. Cyclic tensile tests of Shetland pony superficial digital flexor tendons (SDFTs) with an optimized cryo-clamp combined with biplanar high-speed fluoroscopy. BMC Vet Res 2021; 17:223. [PMID: 34172051 PMCID: PMC8229380 DOI: 10.1186/s12917-021-02914-w] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/08/2020] [Accepted: 05/24/2021] [Indexed: 01/20/2023] Open
Abstract
Background Long-term cyclic tensile testing with equine palmar/plantar tendons have not yet been performed due to problems in fixing equine tendons securely and loading them cyclically. It is well established that the biomechanical response of tendons varies during cyclic loading over time. The aim of this study was to develop a clamping device that enables repetitive cyclic tensile testing of equine superficial digital flexor tendon for at least 60 loading cycles and for 5 min. Results A novel cryo-clamp was developed and built. Healthy and collagenase-treated pony SDFTs were mounted in the custom-made cryo-clamp for the proximal tendon end and a special clamping device for the short pastern bone (os coronale). Simultaneously with tensile testing, we used a biplanar high-speed fluoroscopy system (FluoKin) to track tendon movement. The FluoKin system was additionally validated in precision measurements. During the cyclic tensile tests of the SDFTs, the average maximal force measured was 325 N and 953 N for a length variation of 2 and 4 % respectively. The resulting stress averaged 16 MPa and 48 MPa respectively, while the modulus of elasticity was 828 MPa and 1212 MPa respectively. Length variation of the metacarpal region was, on average, 4.87 % higher after incubation with collagenase. The precision of the FluoKin tracking was 0.0377 mm, defined as the standard deviation of pairwise intermarker distances embedded in rigid bodies. The systems accuracy was 0.0287 mm, which is the difference between the machined and mean measured distance. Conclusion In this study, a good performing clamping technique for equine tendons under repetitive cyclic loading conditions is described. The presented cryo-clamps were tested up to 50 min duration and up to the machine maximal capacity of 10 kN. With the possibility of repetitive loading a stabilization of the time-force-curve and changes of hysteresis and creep became obvious after a dozen cycles, which underlines the necessity of repetitive cyclical testing. Furthermore, biplanar high-speed fluoroscopy seems an appropriate and highly precise measurement tool for analysis of tendon behaviour under repetitive load in equine SDFTs. Supplementary Information The online version contains supplementary material available at 10.1186/s12917-021-02914-w.
Collapse
Affiliation(s)
- Franziska C Wagner
- Institute of Veterinary Anatomy, Histology and Embryology, Faculty of Veterinary Medicine, Leipzig University, An den Tierkliniken 43, 04103, Leipzig, Germany.
| | - Sven Reese
- Chair of Anatomy, Histology and Embryology, Department of Veterinary Sciences, LMU Munich, Veterinärstraße 13, 80539, Munich, Germany
| | - Kerstin Gerlach
- Department for Horses, Faculty of Veterinary Medicine, Leipzig University, An den Tierkliniken 21, 04103, Leipzig, Germany
| | - Peter Böttcher
- Small Animal Clinic, Department of Veterinary Medicine, Freie Universität Berlin, Oertzenweg 19 b, 14163, Berlin, Germany
| | - Christoph K W Mülling
- Institute of Veterinary Anatomy, Histology and Embryology, Faculty of Veterinary Medicine, Leipzig University, An den Tierkliniken 43, 04103, Leipzig, Germany
| |
Collapse
|
7
|
Siadat SM, Zamboulis DE, Thorpe CT, Ruberti JW, Connizzo BK. Tendon Extracellular Matrix Assembly, Maintenance and Dysregulation Throughout Life. ADVANCES IN EXPERIMENTAL MEDICINE AND BIOLOGY 2021; 1348:45-103. [PMID: 34807415 DOI: 10.1007/978-3-030-80614-9_3] [Citation(s) in RCA: 16] [Impact Index Per Article: 5.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 01/10/2023]
Abstract
In his Lissner Award medal lecture in 2000, Stephen Cowin asked the question: "How is a tissue built?" It is not a new question, but it remains as relevant today as it did when it was asked 20 years ago. In fact, research on the organization and development of tissue structure has been a primary focus of tendon and ligament research for over two centuries. The tendon extracellular matrix (ECM) is critical to overall tissue function; it gives the tissue its unique mechanical properties, exhibiting complex non-linear responses, viscoelasticity and flow mechanisms, excellent energy storage and fatigue resistance. This matrix also creates a unique microenvironment for resident cells, allowing cells to maintain their phenotype and translate mechanical and chemical signals into biological responses. Importantly, this architecture is constantly remodeled by local cell populations in response to changing biochemical (systemic and local disease or injury) and mechanical (exercise, disuse, and overuse) stimuli. Here, we review the current understanding of matrix remodeling throughout life, focusing on formation and assembly during the postnatal period, maintenance and homeostasis during adulthood, and changes to homeostasis in natural aging. We also discuss advances in model systems and novel tools for studying collagen and non-collagenous matrix remodeling throughout life, and finally conclude by identifying key questions that have yet to be answered.
Collapse
Affiliation(s)
| | - Danae E Zamboulis
- Institute of Life Course and Medical Sciences, Faculty of Health and Life Sciences, University of Liverpool, Liverpool, UK
| | - Chavaunne T Thorpe
- Comparative Biomedical Sciences, The Royal Veterinary College, University of London, London, UK
| | - Jeffrey W Ruberti
- Department of Bioengineering, Northeastern University, Boston, MA, USA
| | - Brianne K Connizzo
- Department of Biomedical Engineering, Boston University, Boston, MA, USA.
| |
Collapse
|
8
|
Dry vs. wet: Properties and performance of collagen films. Part II. Cyclic and time-dependent behaviours. J Mech Behav Biomed Mater 2020; 112:104040. [DOI: 10.1016/j.jmbbm.2020.104040] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/05/2020] [Revised: 08/08/2020] [Accepted: 08/12/2020] [Indexed: 12/21/2022]
|
9
|
Lin AH, Allan AN, Zitnay JL, Kessler JL, Yu SM, Weiss JA. Collagen denaturation is initiated upon tissue yield in both positional and energy-storing tendons. Acta Biomater 2020; 118:153-160. [PMID: 33035697 DOI: 10.1016/j.actbio.2020.09.056] [Citation(s) in RCA: 14] [Impact Index Per Article: 3.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/11/2020] [Revised: 09/04/2020] [Accepted: 09/30/2020] [Indexed: 12/12/2022]
Abstract
Tendons are collagenous soft tissues that transmit loads between muscles and bones. Depending on their anatomical function, tendons are classified as positional or energy-storing with differing biomechanical and biochemical properties. We recently demonstrated that during monotonic stretch of positional tendons, permanent denatured collagen begins accumulating upon departing the linear region of the stress-strain curve. However, it is unknown if this observation is true during mechanical overload of other types of tendons. Therefore, the purpose of this study was to investigate the onset of collagen denaturation relative to applied strain, and whether it differs between the two tendon types. Rat tail tendon (RTT) fascicles and rat flexor digitorum longus (FDL) tendons represented positional and energy-storing tendons, respectively. The samples were stretched to incremental levels of strain, then stained with fluorescently labeled collagen hybridizing peptides (CHPs); the CHP fluorescence was measured to quantify denatured collagen. Denatured collagen in both positional and energy-storing tendons began to increase at the yield strain, upon leaving the linear region of the stress-strain curve as the sample started to permanently deform. Despite significant differences between the two tendon types, it appears that collagen denaturation is initiated at tissue yield during monotonic stretch, and the fundamental mechanism of failure is the same for the two types of tendons. At tissue failure, positional tendons had double the percentage of denatured collagen compared to energy-storing tendons, with no difference between 0% control groups. These results help to elucidate the etiology of subfailure injury and rupture in functionally distinct tendons.
Collapse
Affiliation(s)
- Allen H Lin
- Department of Biomedical Engineering, University of Utah, United States; Scientific Computing and Imaging Institute, University of Utah, United States
| | - Alexandra N Allan
- Department of Biomedical Engineering, University of Utah, United States; Scientific Computing and Imaging Institute, University of Utah, United States
| | - Jared L Zitnay
- Department of Biomedical Engineering, University of Utah, United States; Scientific Computing and Imaging Institute, University of Utah, United States
| | - Julian L Kessler
- Department of Biomedical Engineering, University of Utah, United States
| | - S Michael Yu
- Department of Biomedical Engineering, University of Utah, United States; Department of Pharmaceutics and Pharmaceutical Chemistry, University of Utah, United States
| | - Jeffrey A Weiss
- Department of Biomedical Engineering, University of Utah, United States; Scientific Computing and Imaging Institute, University of Utah, United States; Department of Orthopaedics, University of Utah, United States.
| |
Collapse
|
10
|
Wunderli SL, Blache U, Snedeker JG. Tendon explant models for physiologically relevant invitro study of tissue biology - a perspective. Connect Tissue Res 2020; 61:262-277. [PMID: 31931633 DOI: 10.1080/03008207.2019.1700962] [Citation(s) in RCA: 25] [Impact Index Per Article: 6.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 02/03/2023]
Abstract
Background: Tendon disorders increasingly afflict our aging society but we lack the scientific understanding to clinically address them. Clinically relevant models of tendon disease are urgently needed as established small animal models of tendinopathy fail to capture essential aspects of the disease. Two-dimensional and three-dimensional cell and tissue culture models are similarly limited, lacking many physiological extracellular matrix cues required to maintain tissue homeostasis or guide matrix remodeling. These cues reflect the biochemical and biomechanical status of the tissue, and encode information regarding the mechanical and metabolic competence of the tissue. Tendon explants overcome some of these limitations and have thus emerged as a valuable tool for the discovery and study of mechanisms associated with tendon homeostasis and pathophysiology. Tendon explants retain native cell-cell and cell-matrix connections, while allowing highly reproducible experimental control over extrinsic factors like mechanical loading and nutritional availability. In this sense tendon explant models can deliver insights that are otherwise impossible to obtain from in vivo animal or in vitro cell culture models. Purpose: In this review, we aimed to provide an overview of tissue explant models used in tendon research, with a specific focus on the value of explant culture systems for the controlled study of the tendon core tissue. We discuss their advantages, limitations and potential future utility. We include suggestions and technical recommendations for the successful use of tendon explant cultures and conclude with an outlook on how explant models may be leveraged with state-of-the-art biotechnologies to propel our understanding of tendon physiology and pathology.
Collapse
Affiliation(s)
- Stefania L Wunderli
- University Hospital Balgrist, University of Zurich, Zurich, Switzerland.,Institute for Biomechanics, ETH Zurich, Zurich, Switzerland
| | - Ulrich Blache
- University Hospital Balgrist, University of Zurich, Zurich, Switzerland.,Institute for Biomechanics, ETH Zurich, Zurich, Switzerland
| | - Jess G Snedeker
- University Hospital Balgrist, University of Zurich, Zurich, Switzerland.,Institute for Biomechanics, ETH Zurich, Zurich, Switzerland
| |
Collapse
|
11
|
Herod TW, Veres SP. ISSLS PRIZE IN BASIC SCIENCE 2020: Beyond microstructure—circumferential specialization within the lumbar intervertebral disc annulus extends to collagen nanostructure, with counterintuitive relationships to macroscale material properties. EUROPEAN SPINE JOURNAL : OFFICIAL PUBLICATION OF THE EUROPEAN SPINE SOCIETY, THE EUROPEAN SPINAL DEFORMITY SOCIETY, AND THE EUROPEAN SECTION OF THE CERVICAL SPINE RESEARCH SOCIETY 2019; 29:670-685. [DOI: 10.1007/s00586-019-06223-7] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Received: 10/11/2019] [Revised: 10/11/2019] [Accepted: 11/15/2019] [Indexed: 02/07/2023]
|
12
|
Choi RK, Smith MM, Smith S, Little CB, Clarke EC. Functionally distinct tendons have different biomechanical, biochemical and histological responses to in vitro unloading. J Biomech 2019; 95:109321. [DOI: 10.1016/j.jbiomech.2019.109321] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/25/2019] [Revised: 08/02/2019] [Accepted: 08/15/2019] [Indexed: 01/29/2023]
|
13
|
Obuchowicz R, Ekiert M, Kohut P, Holak K, Ambrozinski L, Tomaszewski K, Uhl T, Mlyniec A. Interfascicular matrix-mediated transverse deformation and sliding of discontinuous tendon subcomponents control the viscoelasticity and failure of tendons. J Mech Behav Biomed Mater 2019; 97:238-246. [DOI: 10.1016/j.jmbbm.2019.05.027] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/22/2019] [Revised: 05/15/2019] [Accepted: 05/17/2019] [Indexed: 02/05/2023]
|
14
|
Ackerman JE, Nichols AEC, Studentsova V, Best KT, Knapp E, Loiselle AE. Cell non-autonomous functions of S100a4 drive fibrotic tendon healing. eLife 2019; 8:e45342. [PMID: 31124787 PMCID: PMC6546390 DOI: 10.7554/elife.45342] [Citation(s) in RCA: 35] [Impact Index Per Article: 7.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/18/2019] [Accepted: 05/23/2019] [Indexed: 12/13/2022] Open
Abstract
Identification of pro-regenerative approaches to improve tendon healing is critically important as the fibrotic healing response impairs physical function. In the present study we tested the hypothesis that S100a4 haploinsufficiency or inhibition of S100a4 signaling improves tendon function following acute injury and surgical repair in a murine model. We demonstrate that S100a4 drives fibrotic tendon healing primarily through a cell non-autonomous process, with S100a4 haploinsufficiency promoting regenerative tendon healing. Moreover, inhibition of S100a4 signaling via antagonism of its putative receptor, RAGE, also decreases scar formation. Mechanistically, S100a4 haploinsufficiency decreases myofibroblast and macrophage content at the site of injury, with both cell populations being key drivers of fibrotic progression. Moreover, S100a4-lineage cells become α-SMA+ myofibroblasts, via loss of S100a4 expression. Using a combination of genetic mouse models, small molecule inhibitors and in vitro studies we have defined S100a4 as a novel, promising therapeutic candidate to improve tendon function after acute injury.
Collapse
Affiliation(s)
- Jessica E Ackerman
- Center for Musculoskeletal Research, Department of Orthopaedics and RehabilitationUniversity of Rochester Medical CenterRochesterUnited States
| | - Anne EC Nichols
- Center for Musculoskeletal Research, Department of Orthopaedics and RehabilitationUniversity of Rochester Medical CenterRochesterUnited States
| | - Valentina Studentsova
- Center for Musculoskeletal Research, Department of Orthopaedics and RehabilitationUniversity of Rochester Medical CenterRochesterUnited States
| | - Katherine T Best
- Center for Musculoskeletal Research, Department of Orthopaedics and RehabilitationUniversity of Rochester Medical CenterRochesterUnited States
| | - Emma Knapp
- Center for Musculoskeletal Research, Department of Orthopaedics and RehabilitationUniversity of Rochester Medical CenterRochesterUnited States
| | - Alayna E Loiselle
- Center for Musculoskeletal Research, Department of Orthopaedics and RehabilitationUniversity of Rochester Medical CenterRochesterUnited States
| |
Collapse
|
15
|
Udeze CP, Jones ER, Riley GP, Morrissey D, Screen HRC. An in vitro investigation into the effects of 10 Hz cyclic loading on tenocyte metabolism. Scand J Med Sci Sports 2019; 29:1511-1520. [PMID: 31102473 DOI: 10.1111/sms.13465] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/27/2018] [Revised: 03/25/2019] [Accepted: 04/30/2019] [Indexed: 12/25/2022]
Abstract
Tendinopathy is a prevalent, highly debilitating condition, with poorly defined etiology. A wide range of clinical treatments has been proposed, with systematic reviews largely supporting shock wave therapy or eccentric exercise. Characterizing these treatments have demonstrated both generate perturbations within tendon at a frequency of approximately 8-12 Hz. Consequently, it is hypothesized that loading in this frequency range initiates increased anabolic tenocyte behavior, promoting tendon repair. The primary aim of this study was to investigate the effects of 10 Hz perturbations on tenocyte metabolism, comparing gene expression in response to a 10 Hz and 1 Hz loading profile. Tenocytes from healthy and tendinopathic human tendons were seeded into 3D collagen gels and subjected to 15 minutes cyclic strain at 10 Hz or 1 Hz. Tenocytes from healthy tendon showed increased expression of all analyzed genes in response to loading, with significantly increased expression of inflammatory and degradative genes with 10 Hz, relative to 1 Hz loading. By contrast, whilst the response of tenocytes from tendinopathy tendon also increased with 10 Hz loading, the overall response profile was more varied and less intense, possibly indicative of an altered healing response. Through inhibition of the pathway, IL1 was shown to be involved in the degradative and catabolic response of cells to high-frequency loading, abrogating the loading response. This study has demonstrated for the first time that loading at a frequency of 10 Hz may enhance the metabolic response of tenocytes by initiating an immediate degradatory and inflammatory cell response through the IL1 pathway, perhaps as an initial stage of tendon healing.
Collapse
Affiliation(s)
- Chineye P Udeze
- School of Engineering and Material Science, Queen Mary University of London, London, UK
| | | | | | - Dylan Morrissey
- Sport and Exercise Medicine, Queen Mary University of London, London, UK.,Physiotherapy Department, Bart's Health NHS Trust, London, UK
| | - Hazel R C Screen
- School of Engineering and Material Science, Queen Mary University of London, London, UK
| |
Collapse
|
16
|
Zitnay JL, Weiss JA. Load transfer, damage, and failure in ligaments and tendons. J Orthop Res 2018; 36:3093-3104. [PMID: 30175857 PMCID: PMC6454883 DOI: 10.1002/jor.24134] [Citation(s) in RCA: 27] [Impact Index Per Article: 4.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 05/07/2018] [Accepted: 08/14/2018] [Indexed: 02/04/2023]
Abstract
The function of ligaments and tendons is to support and transmit loads applied to the musculoskeletal system. These tissues are often able to perform their function for many decades; however, connective tissue disease and injury can compromise ligament and tendon integrity. A range of protein and non-protein constituents, combined in a complex structural hierarchy from the collagen molecule to the tissue and covering nanometer to centimeter length scales, govern tissue function, and impart characteristic non-linear material behavior. This review summarizes the structure of ligaments and tendons, the roles of their constituent components for load transfer across the hierarchy of structure, and the current understanding of how damage occurs in these tissues. Disease and injury can alter the constituent make-up and structural organization of ligaments and tendons, affecting tissue function, while also providing insight to the role and interactions of individual constituents. The studies and techniques presented here have helped to understand the relationship between tissue constituents and the physical mechanisms (e.g., stretching, sliding) that govern material behavior at and between length scales. In recent years, new techniques have been developed to probe ever smaller length scales and may help to elucidate mechanisms of load transfer and damage and the molecular constituents involved in the in the earliest stages of ligament and tendon damage. A detailed understanding of load transfer and damage from the molecular to the tissue level may elucidate targets for the treatment of connective tissue diseases and inform practice to prevent and rehabilitate ligament and tendon injuries. © 2018 Orthopaedic Research Society. Published by Wiley Periodicals, Inc. J Orthop Res 36:3093-3104, 2018.
Collapse
Affiliation(s)
- Jared L. Zitnay
- Department of Bioengineering, and Scientific Computing and Imaging Institute University of Utah
| | - Jeffrey A. Weiss
- Department of Bioengineering, and Scientific Computing and Imaging Institute University of Utah,Department of Orthopaedics, University of Utah
| |
Collapse
|
17
|
Chambers NC, Herod TW, Veres SP. Ultrastructure of tendon rupture depends on strain rate and tendon type. J Orthop Res 2018; 36:2842-2850. [PMID: 29901228 DOI: 10.1002/jor.24067] [Citation(s) in RCA: 18] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 11/23/2017] [Accepted: 06/03/2018] [Indexed: 02/04/2023]
Abstract
Previous research has shown that both the mechanics and elongation mechanisms of tendon and ligament vary with strain rate during tensile loading. In this study, we sought to determine if the ultrastructural damage created during tendon rupture also varies with strain rate. A bovine forelimb model was used, allowing two anatomically proximate but physiologically distinct tendons to be studies: the positional common digital extensor tendon, and the energy storing superficial digital flexor tendon. Samples from the two tendon types were ruptured at rates of either 1%/s or 10%/s. Relative to unruptured control samples, changes to collagen fibril structure were assessed using scanning electron microscopy (SEM), and changes to collagen molecule packing were studied using differential scanning calorimetry (DSC). Rupture at 1%/s caused discrete plasticity damage that extended along the length of collagen fibrils in both the extensor and flexor tendons. Consistent with this, DSC showed molecular packing disruption relative to control samples. Both SEM and DSC showed that extensor tendon fibrils sustained more severe damage than the more highly crosslinked flexor tendon fibrils. Increasing strain rate during rupture decreased the level of longitudinal disruption experienced by the collagen fibrils of both tendon types. Disruption to D-banding was no longer seen in the extensor tendon fibrils, and discrete plasticity damage was completely eliminated in the flexor tendon fibrils, indicating a transition to localized point failure. Ultrastructural damage resulting from tendon rupture depends on both strain rate and tendon type. © 2018 Orthopaedic Research Society. Published by Wiley Periodicals, Inc. J Orthop Res 36:2842-2850, 2018.
Collapse
Affiliation(s)
- Neil C Chambers
- Division of Engineering, Saint Mary's University, Halifax, Nova Scotia, Canada
| | - Tyler W Herod
- School of Biomedical Engineering, Dalhousie University, Halifax, Nova Scotia, Canada
| | - Samuel P Veres
- Division of Engineering, Saint Mary's University, Halifax, Nova Scotia, Canada
- School of Biomedical Engineering, Dalhousie University, Halifax, Nova Scotia, Canada
| |
Collapse
|
18
|
Delgado Caceres M, Pfeifer CG, Docheva D. Understanding Tendons: Lessons from Transgenic Mouse Models. Stem Cells Dev 2018; 27:1161-1174. [PMID: 29978741 PMCID: PMC6121181 DOI: 10.1089/scd.2018.0121] [Citation(s) in RCA: 21] [Impact Index Per Article: 3.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/07/2018] [Accepted: 07/05/2018] [Indexed: 12/26/2022] Open
Abstract
Tendons and ligaments are connective tissues that have been comparatively less studied than muscle and cartilage/bone, even though they are crucial for proper function of the musculoskeletal system. In tendon biology, considerable progress has been made in identifying tendon-specific genes (Scleraxis, Mohawk, and Tenomodulin) in the past decade. However, besides tendon function and the knowledge of a small number of important players in tendon biology, neither the ontogeny of the tenogenic lineage nor signaling cascades have been fully understood. This results in major drawbacks in treatment and repair options following tendon degeneration. In this review, we have systematically evaluated publications describing tendon-related genes, which were studied in depth and characterized by using knockout technologies and the subsequently generated transgenic mouse models (Tg) (knockout mice, KO). We report in a tabular manner, that from a total of 24 tendon-related genes, in 22 of the respective knockout mouse models, phenotypic changes were detected. Additionally, in some of the models it was described at which developmental stages these changes appeared and progressed. To summarize, only loss of Scleraxis and TGFβ signaling led to severe tendon developmental phenotypes, while mice deficient for various proteoglycans, Mohawk, EGR1 and 2, and Tenomodulin presented mild phenotypes. These data suggest that the tendon developmental system is well organized, orchestrated, and backed up; this is even more evident among the members of the proteoglycan family, where the compensatory effects are much clearer. In future, it will be of great importance to discover additional master tendon transcription factors and the genes that play crucial roles in tendon development. This would improve our understanding of the genetic makeup of tendons, and will increase the chances of generating tendon-specific drugs to advance overall treatment strategies.
Collapse
Affiliation(s)
- Manuel Delgado Caceres
- Experimental Trauma Surgery, Department of Trauma Surgery, University Regensburg Medical Centre, Regensburg, Germany
| | - Christian G. Pfeifer
- Experimental Trauma Surgery, Department of Trauma Surgery, University Regensburg Medical Centre, Regensburg, Germany
- Department of Trauma Surgery, University Regensburg Medical Centre, Regensburg, Germany
| | - Denitsa Docheva
- Experimental Trauma Surgery, Department of Trauma Surgery, University Regensburg Medical Centre, Regensburg, Germany
- Department of Medical Biology, Medical University-Plovdiv, Plovdiv, Bulgaria
| |
Collapse
|
19
|
Herod TW, Veres SP. Development of overuse tendinopathy: A new descriptive model for the initiation of tendon damage during cyclic loading. J Orthop Res 2018; 36:467-476. [PMID: 28598009 DOI: 10.1002/jor.23629] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 11/08/2016] [Accepted: 06/05/2017] [Indexed: 02/04/2023]
Abstract
Tendinopathic tissue has long been characterized by changes to collagen microstructure. However, initial tendon damage from excessive mechanical loading-a hallmark of tendinopathy development-could occur at the nanoscale level of collagen fibrils. Indeed, it is on this scale that tenocytes interact directly with tendon matrix, and excessive collagen fibril damage not visible at the microscale could trigger a degenerative cascade. In this study, we explored whether initiation of tendon damage during cyclic loading occurs via a longitudinal compression-induced buckling mechanism of collagen fibrils leading to nanoscale kinkband development. Two groups of tendons were cyclically loaded to equivalent peak stresses. In each loading cycle, tendons in one group were unloaded to the zero displacement mark, while those in the other group were unloaded to a nominal level of tension, minimizing the potential for fibril buckling. Tendons that were unloaded to the zero displacement mark ruptured significantly sooner during cyclic loading (1,446 ± 737 vs. 4,069 ± 1,129 cycles), indicating that significant fatigue damage is accrued in the low stress, toe region of the load-deformation response. Ultrastructural analysis using scanning electron microscopy of tendons stopped after 1,000 cycles showed that maintaining a nominal tension slowed the accumulation of kinkbands, supporting a longitudinal compression-induced buckling mechanism as the basis for kinkband development. Based on our results, we present a new descriptive model for the initiation of tendon damage during cyclic loading. The so-called Compression of Unrecovered Elongation or CUE Model may provide useful insight into the development of tendinopathy. © 2017 Orthopaedic Research Society. Published by Wiley Periodicals, Inc. J Orthop Res 36:467-476, 2018.
Collapse
Affiliation(s)
- Tyler W Herod
- School of Biomedical Engineering, Dalhousie University, Halifax, Nova Scotia, Canada
| | - Samuel P Veres
- School of Biomedical Engineering, Dalhousie University, Halifax, Nova Scotia, Canada.,Division of Engineering, Saint Mary's University, 923 Robie Street, Halifax, Nova Scotia Canada B3H 3C3
| |
Collapse
|
20
|
Ackerman JE, Bah I, Jonason JH, Buckley MR, Loiselle AE. Aging does not alter tendon mechanical properties during homeostasis, but does impair flexor tendon healing. J Orthop Res 2017; 35:2716-2724. [PMID: 28419543 PMCID: PMC5645212 DOI: 10.1002/jor.23580] [Citation(s) in RCA: 31] [Impact Index Per Article: 4.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 11/23/2016] [Accepted: 04/12/2017] [Indexed: 02/04/2023]
Abstract
Aging is an important factor in disrupted homeostasis of many tissues. While an increased incidence of tendinopathy and tendon rupture are observed with aging, it is unclear whether this is due to progressive changes in tendon cell function and mechanics over time, or an impaired repair reaction from aged tendons in response to insult or injury. In the present study, we examined changes in the mechanical properties of Flexor Digitorum Longus (FDL), Flexor Carpi Ulnaris (FCU), and tail fascicles in both male and female C57Bl/6 mice between 3 and 27 months of age to better understand the effects of sex and age on tendon homeostasis. No change in max load at failure was observed in any group over the course of aging, although there were significant decreases in toe and linear stiffness in female mice from 3 to 15 months, and 3 to 27 months. No changes in cell proliferation were observed with aging, although an observable decrease in cellularity occurred in 31-month old tendons. Given that aging did not dramatically alter tendon mechanical homeostasis we hypothesized that a disruption in tendon homeostasis, via acute injury would result in an impaired healing response. Significant decreases in max load, stiffness, and yield load were observed in repairs of 22-month old mice, relative to 4-month old mice. No changes in cell proliferation were observed between young and aged, however, a dramatic loss of bridging collagen extracellular matrix was observed in aged repairs suggest that matrix production, but not cell proliferation leads to impaired tendon healing with aging. Results © 2017 Orthopaedic Research Society. Published by Wiley Periodicals, Inc. J Orthop Res 35:2716-2724, 2017.
Collapse
Affiliation(s)
- Jessica E. Ackerman
- Center for Musculoskeletal Research, Department of Orthopaedics & Rehabilitation, University of Rochester Medical Center, Rochester, NY 14642
| | - Ibrahima Bah
- Center for Musculoskeletal Research, Department of Orthopaedics & Rehabilitation, University of Rochester Medical Center, Rochester, NY 14642,Department of Biomedical Engineering, University of Rochester, Rochester, NY 14642
| | - Jennifer H. Jonason
- Center for Musculoskeletal Research, Department of Orthopaedics & Rehabilitation, University of Rochester Medical Center, Rochester, NY 14642
| | - Mark R. Buckley
- Center for Musculoskeletal Research, Department of Orthopaedics & Rehabilitation, University of Rochester Medical Center, Rochester, NY 14642,Department of Biomedical Engineering, University of Rochester, Rochester, NY 14642
| | - Alayna E. Loiselle
- Center for Musculoskeletal Research, Department of Orthopaedics & Rehabilitation, University of Rochester Medical Center, Rochester, NY 14642,Corresponding Author: Alayna E. Loiselle, PhD, Center for Musculoskeletal Research, University of Rochester Medical Center, 601 Elmwood Ave, Box 665, Rochester, NY, 14642, Phone: 585-275-7239, Fax: 585-276-2177,
| |
Collapse
|
21
|
Godinho MSC, Thorpe CT, Greenwald SE, Screen HRC. Elastin is Localised to the Interfascicular Matrix of Energy Storing Tendons and Becomes Increasingly Disorganised With Ageing. Sci Rep 2017; 7:9713. [PMID: 28855560 PMCID: PMC5577209 DOI: 10.1038/s41598-017-09995-4] [Citation(s) in RCA: 54] [Impact Index Per Article: 7.7] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/25/2017] [Accepted: 08/01/2017] [Indexed: 11/10/2022] Open
Abstract
Tendon is composed of fascicles bound together by the interfascicular matrix (IFM). Energy storing tendons are more elastic and extensible than positional tendons; behaviour provided by specialisation of the IFM to enable repeated interfascicular sliding and recoil. With ageing, the IFM becomes stiffer and less fatigue resistant, potentially explaining why older tendons become more injury-prone. Recent data indicates enrichment of elastin within the IFM, but this has yet to be quantified. We hypothesised that elastin is more prevalent in energy storing than positional tendons, and is mainly localised to the IFM. Further, we hypothesised that elastin becomes disorganised and fragmented, and decreases in amount with ageing, especially in energy storing tendons. Biochemical analyses and immunohistochemical techniques were used to determine elastin content and organisation, in young and old equine energy storing and positional tendons. Supporting the hypothesis, elastin localises to the IFM of energy storing tendons, reducing in quantity and becoming more disorganised with ageing. These changes may contribute to the increased injury risk in aged energy storing tendons. Full understanding of the processes leading to loss of elastin and its disorganisation with ageing may aid in the development of treatments to prevent age related tendinopathy.
Collapse
Affiliation(s)
- Marta S C Godinho
- Institute of Bioengineering, School of Engineering and Materials Science, Queen Mary University of London, London, E1 4NS, United Kingdom
| | - Chavaunne T Thorpe
- Comparative Biomedical Sciences, The Royal Veterinary College, Royal College Street, London, NW1 0TU, United Kingdom
| | - Steve E Greenwald
- Blizard Institute, Barts and London School of Medicine and Dentistry, Turner Street, London, E1 11BB, United Kingdom
| | - Hazel R C Screen
- Institute of Bioengineering, School of Engineering and Materials Science, Queen Mary University of London, London, E1 4NS, United Kingdom.
| |
Collapse
|
22
|
Fang F, Lake SP. Experimental evaluation of multiscale tendon mechanics. J Orthop Res 2017; 35:1353-1365. [PMID: 27878999 DOI: 10.1002/jor.23488] [Citation(s) in RCA: 23] [Impact Index Per Article: 3.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 09/02/2016] [Accepted: 11/16/2016] [Indexed: 02/04/2023]
Abstract
Tendon's primary function is a mechanical link between muscle and bone. The hierarchical structure of tendon and specific compositional constituents are believed to be critical for proper mechanical function. With increased appreciation for tendon importance and the development of various technological advances, this review paper summarizes recent experimental approaches that have been used to study multiscale tendon mechanics, includes an overview of studies that have evaluated the role of specific tissue constituents, and also proposes challenges/opportunities facing tendon study. Tendon has been demonstrated to have specific structural characteristics (e.g., multi-level hierarchy, crimp pattern, helix) and complex mechanical properties (e.g., non-linearity, anisotropy, viscoelasticity). Physical mechanisms including uncrimping, fiber sliding, and collagen reorganization have been shown to govern tendon mechanical responses under both static and dynamic loading. Several tendon constituents with relatively small quantities have been suggested to play a role in its mechanics, although some results are conflicting. Further research should be performed to understand the interplay and communication of tendon mechanical properties across levels of the hierarchical structure, and further show how each of these components contribute to tendon mechanics. The studies summarized and discussed in this review have helped elucidate important aspects of multiscale tendon mechanics, which is a prerequisite for analyzing stress/strain transfer between multiple scales and identifying key principles of mechanotransduction. This information could further facilitate interpreting the functional diversity of tendons from different species, different locations, and even different developmental stages, and then better understand and identify fundamental concepts related to tendon degeneration, disease, and healing. © 2017 Orthopaedic Research Society. Published by Wiley Periodicals, Inc. J Orthop Res 35:1353-1365, 2017.
Collapse
Affiliation(s)
- Fei Fang
- Department of Mechanical Engineering and Materials Science, Washington University in St. Louis, 1 Brookings Drive, Campus Box 1185, St. Louis, Missouri, 63130
| | - Spencer P Lake
- Department of Mechanical Engineering and Materials Science, Washington University in St. Louis, 1 Brookings Drive, Campus Box 1185, St. Louis, Missouri, 63130.,Department of Biomedical Engineering, Washington University in St. Louis, 1 Brookings Drive, Campus Box 1185, St. Louis, Missouri, 63130.,Department of Orthopaedic Surgery, Washington University in St. Louis, 1 Brookings Drive, Campus Box 1185, St. Louis, Missouri, 63130
| |
Collapse
|
23
|
Zitnay JL, Li Y, Qin Z, San BH, Depalle B, Reese SP, Buehler MJ, Yu SM, Weiss JA. Molecular level detection and localization of mechanical damage in collagen enabled by collagen hybridizing peptides. Nat Commun 2017; 8:14913. [PMID: 28327610 PMCID: PMC5364439 DOI: 10.1038/ncomms14913] [Citation(s) in RCA: 143] [Impact Index Per Article: 20.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/25/2015] [Accepted: 02/14/2017] [Indexed: 02/06/2023] Open
Abstract
Mechanical injury to connective tissue causes changes in collagen structure and material behaviour, but the role and mechanisms of molecular damage have not been established. In the case of mechanical subfailure damage, no apparent macroscale damage can be detected, yet this damage initiates and potentiates in pathological processes. Here, we utilize collagen hybridizing peptide (CHP), which binds unfolded collagen by triple helix formation, to detect molecular level subfailure damage to collagen in mechanically stretched rat tail tendon fascicle. Our results directly reveal that collagen triple helix unfolding occurs during tensile loading of collagenous tissues and thus is an important damage mechanism. Steered molecular dynamics simulations suggest that a likely mechanism for triple helix unfolding is intermolecular shearing of collagen α-chains. Our results elucidate a probable molecular failure mechanism associated with subfailure injuries, and demonstrate the potential of CHP targeting for diagnosis, treatment and monitoring of tissue disease and injury. Collagen denaturation is thought to occur during tissue mechanical damage, but its role in damage initiation is still unclear. Here, the authors use a collagen hybridizing peptide to provide insights into the molecular mechanisms leading to collagen unfolding during tendon mechanical stretch.
Collapse
Affiliation(s)
- Jared L Zitnay
- Department of Bioengineering, University of Utah, Salt Lake City, Utah 84112, USA.,Scientific Computing and Imaging Institute, University of Utah, Salt Lake City, Utah 84112, USA
| | - Yang Li
- Department of Bioengineering, University of Utah, Salt Lake City, Utah 84112, USA
| | - Zhao Qin
- Laboratory for Atomistic and Molecular Mechanics, Department of Civil and Environmental Engineering, Massachusetts Institute of Technology, Cambridge, Massachusetts 02139, USA
| | - Boi Hoa San
- Department of Bioengineering, University of Utah, Salt Lake City, Utah 84112, USA
| | - Baptiste Depalle
- Laboratory for Atomistic and Molecular Mechanics, Department of Civil and Environmental Engineering, Massachusetts Institute of Technology, Cambridge, Massachusetts 02139, USA
| | - Shawn P Reese
- Department of Bioengineering, University of Utah, Salt Lake City, Utah 84112, USA.,Scientific Computing and Imaging Institute, University of Utah, Salt Lake City, Utah 84112, USA
| | - Markus J Buehler
- Laboratory for Atomistic and Molecular Mechanics, Department of Civil and Environmental Engineering, Massachusetts Institute of Technology, Cambridge, Massachusetts 02139, USA
| | - S Michael Yu
- Department of Bioengineering, University of Utah, Salt Lake City, Utah 84112, USA.,Department of Pharmaceutics and Pharmaceutical Chemistry, University of Utah, Salt Lake City, Utah 84112, USA
| | - Jeffrey A Weiss
- Department of Bioengineering, University of Utah, Salt Lake City, Utah 84112, USA.,Scientific Computing and Imaging Institute, University of Utah, Salt Lake City, Utah 84112, USA.,Department of Orthopedics, University of Utah, Salt Lake City, Utah 84108, USA
| |
Collapse
|
24
|
Herod TW, Chambers NC, Veres SP. Collagen fibrils in functionally distinct tendons have differing structural responses to tendon rupture and fatigue loading. Acta Biomater 2016; 42:296-307. [PMID: 27321189 DOI: 10.1016/j.actbio.2016.06.017] [Citation(s) in RCA: 62] [Impact Index Per Article: 7.8] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/04/2016] [Revised: 06/03/2016] [Accepted: 06/10/2016] [Indexed: 12/24/2022]
Abstract
UNLABELLED In this study we investigate relationships between the nanoscale structure of collagen fibrils and the macroscale functional response of collagenous tissues. To do so, we study two functionally distinct classes of tendons, positional tendons and energy storing tendons, using a bovine forelimb model. Molecular-level assessment using differential scanning calorimetry (DSC), functional crosslink assessment using hydrothermal isometric tension (HIT) analysis, and ultrastructural assessment using scanning electron microscopy (SEM) were used to study undamaged, ruptured, and cyclically loaded samples from the two tendon types. HIT indicated differences in both crosslink type and crosslink density, with flexor tendons having more thermally stable crosslinks than the extensor tendons (higher TFmax of >90 vs. 75.1±2.7°C), and greater total crosslink density than the extensor tendons (higher t1/2 of 11.5±1.9 vs. 3.5±1.0h after NaBH4 treatment). Despite having a lower crosslink density than flexor tendons, extensor tendons were significantly stronger (37.6±8.1 vs. 23.1±7.7MPa) and tougher (14.3±3.6 vs. 6.8±3.4MJ/m(3)). SEM showed that collagen fibrils in the tougher, stronger extensor tendons were able to undergo remarkable levels of plastic deformation in the form of discrete plasticity, while those in the flexor tendons were not able to plastically deform. When cyclically loaded, collagen fibrils in extensor tendons accumulated fatigue damage rapidly in the form of kink bands, while those in flexor tendons did not accumulate significant fatigue damage. The results demonstrate that collagen fibrils in functionally distinct tendons respond differently to mechanical loading, and suggests that fibrillar collagens may be subject to a strength vs. fatigue resistance tradeoff. STATEMENT OF SIGNIFICANCE Collagen fibrils-nanoscale biological cables-are the fundamental load-bearing elements of all structural human tissues. While all collagen fibrils share common features, such as being composed of a precise quarter-staggered polymeric arrangement of triple-helical collagen molecules, their structure can vary significantly between tissue types, and even between different anatomical structures of the same tissue type. To understand normal function, homeostasis, and disease of collagenous tissues requires detailed knowledge of collagen fibril structure-function. Using anatomically proximate but structurally distinct tendons, we show that collagen fibrils in functionally distinct tendons have differing susceptibilities to damage under both tensile overload and cyclic fatigue loading. Our results suggest that the structure of collagen fibrils may lead to a strength versus fatigue resistance tradeoff, where high strength is gained at the expense of fatigue resistance, and vice versa.
Collapse
Affiliation(s)
- Tyler W Herod
- School of Biomedical Engineering, Dalhousie University, Halifax, Nova Scotia, Canada
| | - Neil C Chambers
- Division of Engineering, Saint Mary's University, Halifax, Nova Scotia, Canada
| | - Samuel P Veres
- School of Biomedical Engineering, Dalhousie University, Halifax, Nova Scotia, Canada; Division of Engineering, Saint Mary's University, Halifax, Nova Scotia, Canada.
| |
Collapse
|
25
|
Thorpe CT, Riley GP, Birch HL, Clegg PD, Screen HR. Fascicles and the interfascicular matrix show adaptation for fatigue resistance in energy storing tendons. Acta Biomater 2016; 42:308-315. [PMID: 27286677 PMCID: PMC5015572 DOI: 10.1016/j.actbio.2016.06.012] [Citation(s) in RCA: 38] [Impact Index Per Article: 4.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/02/2016] [Revised: 05/06/2016] [Accepted: 06/07/2016] [Indexed: 11/27/2022]
Abstract
Tendon is composed of rope-like fascicles, bound together by interfascicular matrix (IFM). Our previous work shows that the IFM is critical for tendon function, facilitating sliding between fascicles to allow tendons to stretch. This function is particularly important in energy storing tendons, which experience extremely high strains during exercise, and therefore require the capacity for considerable inter-fascicular sliding and recoil. This capacity is not required in positional tendons. Whilst we have previously described the quasi-static properties of the IFM, the fatigue resistance of the IFM in functionally distinct tendons remains unknown. We therefore tested the hypothesis that fascicles and IFM in the energy storing equine superficial digital flexor tendon (SDFT) are more fatigue resistant than those in the positional common digital extensor tendon (CDET). Fascicles and IFM from both tendon types were subjected to cyclic fatigue testing until failure, and mechanical properties were calculated. The results demonstrated that both fascicles and IFM from the energy storing SDFT were able to resist a greater number of cycles before failure than those from the positional CDET. Further, SDFT fascicles and IFM exhibited less hysteresis over the course of testing than their counterparts in the CDET. This is the first study to assess the fatigue resistance of the IFM, demonstrating that IFM has a functional role within tendon and contributes significantly to tendon mechanical properties. These data provide important advances into fully characterising tendon structure-function relationships. Statement of Significance Understanding tendon-structure function relationships is crucial for the development of effective preventative measures and treatments for tendon injury. In this study, we demonstrate for the first time that the interfascicular matrix is able to withstand a high degree of cyclic loading, and is specialised for improved fatigue resistance in energy storing tendons. These findings highlight the importance of the interfascicular matrix in the function of energy storing tendons, and potentially provide new avenues for the development of treatments for tendon injury which specifically target the interfascicular matrix.
Collapse
|
26
|
Khayyeri H, Gustafsson A, Heuijerjans A, Matikainen MK, Julkunen P, Eliasson P, Aspenberg P, Isaksson H. A fibre-reinforced poroviscoelastic model accurately describes the biomechanical behaviour of the rat Achilles tendon. PLoS One 2015; 10:e0126869. [PMID: 26030436 PMCID: PMC4450879 DOI: 10.1371/journal.pone.0126869] [Citation(s) in RCA: 15] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/03/2014] [Accepted: 04/08/2015] [Indexed: 11/19/2022] Open
Abstract
Background Computational models of Achilles tendons can help understanding how healthy tendons are affected by repetitive loading and how the different tissue constituents contribute to the tendon’s biomechanical response. However, available models of Achilles tendon are limited in their description of the hierarchical multi-structural composition of the tissue. This study hypothesised that a poroviscoelastic fibre-reinforced model, previously successful in capturing cartilage biomechanical behaviour, can depict the biomechanical behaviour of the rat Achilles tendon found experimentally. Materials and Methods We developed a new material model of the Achilles tendon, which considers the tendon’s main constituents namely: water, proteoglycan matrix and collagen fibres. A hyperelastic formulation of the proteoglycan matrix enabled computations of large deformations of the tendon, and collagen fibres were modelled as viscoelastic. Specimen-specific finite element models were created of 9 rat Achilles tendons from an animal experiment and simulations were carried out following a repetitive tensile loading protocol. The material model parameters were calibrated against data from the rats by minimising the root mean squared error (RMS) between experimental force data and model output. Results and Conclusions All specimen models were successfully fitted to experimental data with high accuracy (RMS 0.42-1.02). Additional simulations predicted more compliant and soft tendon behaviour at reduced strain-rates compared to higher strain-rates that produce a stiff and brittle tendon response. Stress-relaxation simulations exhibited strain-dependent stress-relaxation behaviour where larger strains produced slower relaxation rates compared to smaller strain levels. Our simulations showed that the collagen fibres in the Achilles tendon are the main load-bearing component during tensile loading, where the orientation of the collagen fibres plays an important role for the tendon’s viscoelastic response. In conclusion, this model can capture the repetitive loading and unloading behaviour of intact and healthy Achilles tendons, which is a critical first step towards understanding tendon homeostasis and function as this biomechanical response changes in diseased tendons.
Collapse
Affiliation(s)
- Hanifeh Khayyeri
- Department of Biomedical Engineering, Lund University, Lund, Sweden
| | - Anna Gustafsson
- Department of Biomedical Engineering, Lund University, Lund, Sweden
| | - Ashley Heuijerjans
- Department of Biomedical Engineering, Eindhoven University of Technology, Eindhoven, Netherlands
| | - Marko K. Matikainen
- Department of Mechanical Engineering, Lappeenranta University of Technology, Lappeenranta, Finland
| | - Petro Julkunen
- Department of Clinical Neurophysiology, Kuopio University Hospital, Kuopio, Finland
- Department of Applied Physics, University of Eastern Finland, Kuopio, Finland
| | - Pernilla Eliasson
- Department of Clinical and Experimental Medicine, Linköping University, Linköping, Sweden
| | - Per Aspenberg
- Department of Clinical and Experimental Medicine, Linköping University, Linköping, Sweden
| | - Hanna Isaksson
- Department of Biomedical Engineering, Lund University, Lund, Sweden
- * E-mail:
| |
Collapse
|
27
|
Freedman BR, Zuskov A, Sarver JJ, Buckley MR, Soslowsky LJ. Evaluating changes in tendon crimp with fatigue loading as an ex vivo structural assessment of tendon damage. J Orthop Res 2015; 33:904-10. [PMID: 25773654 PMCID: PMC4416993 DOI: 10.1002/jor.22875] [Citation(s) in RCA: 32] [Impact Index Per Article: 3.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 11/17/2014] [Accepted: 02/13/2015] [Indexed: 02/04/2023]
Abstract
The complex structure of tendons relates to their mechanical properties. Previous research has associated the waviness of collagen fibers (crimp) during quasi-static tensile loading to tensile mechanical properties, but less is known about the role of fatigue loading on crimp properties. In this study (IACUC approved), mouse patellar tendons were fatigue loaded while an integrated plane polariscope simultaneously assessed crimp properties. We demonstrate a novel structural mechanism whereby tendon crimp amplitude and frequency are altered with fatigue loading. In particular, fatigue loading increased the crimp amplitude across the tendon width and length, and these structural alterations were shown to be both region and load dependent. The change in crimp amplitude was strongly correlated to mechanical tissue laxity (defined as the ratio of displacement and gauge length relative to the first cycle of fatigue loading assessed at constant load throughout testing), at all loads and regions evaluated. Together, this study highlights the role of fatigue loading on tendon crimp properties as a function of load applied and region evaluated, and offers an additional structural mechanism for mechanical alterations that may lead to ultimate tendon failure.
Collapse
Affiliation(s)
- Benjamin R. Freedman
- McKay Orthopaedic Research Laboratory, University of Pennsylvania, Philadelphia, PA, USA
| | | | - Joseph J. Sarver
- McKay Orthopaedic Research Laboratory, University of Pennsylvania, Philadelphia, PA, USA,Department of Biomedical Engineering, Drexel University, Philadelphia, PA, USA
| | - Mark R. Buckley
- McKay Orthopaedic Research Laboratory, University of Pennsylvania, Philadelphia, PA, USA,Department of Biomedical Engineering, University of Rochester, Rochester, NY, USA
| | - Louis J. Soslowsky
- McKay Orthopaedic Research Laboratory, University of Pennsylvania, Philadelphia, PA, USA
| |
Collapse
|
28
|
Freedman BR, Bade ND, Riggin CN, Zhang S, Haines PG, Ong KL, Janmey PA. The (dys)functional extracellular matrix. BIOCHIMICA ET BIOPHYSICA ACTA-MOLECULAR CELL RESEARCH 2015; 1853:3153-64. [PMID: 25930943 DOI: 10.1016/j.bbamcr.2015.04.015] [Citation(s) in RCA: 55] [Impact Index Per Article: 6.1] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 01/14/2015] [Revised: 04/11/2015] [Accepted: 04/13/2015] [Indexed: 10/23/2022]
Abstract
The extracellular matrix (ECM) is a major component of the biomechanical environment with which cells interact, and it plays important roles in both normal development and disease progression. Mechanical and biochemical factors alter the biomechanical properties of tissues by driving cellular remodeling of the ECM. This review provides an overview of the structural, compositional, and mechanical properties of the ECM that instruct cell behaviors. Case studies are reviewed that highlight mechanotransduction in the context of two distinct tissues: tendons and the heart. Although these two tissues demonstrate differences in relative cell-ECM composition and mechanical environment, they share similar mechanisms underlying ECM dysfunction and cell mechanotransduction. Together, these topics provide a framework for a fundamental understanding of the ECM and how it may vary across normal and diseased tissues in response to mechanical and biochemical cues. This article is part of a Special Issue entitled: Mechanobiology.
Collapse
Affiliation(s)
- Benjamin R Freedman
- Department of Bioengineering, University of Pennsylvania, Philadelphia, PA, USA
| | - Nathan D Bade
- Department of Chemical and Biomolecular Engineering, University of Pennsylvania, Philadelphia, PA, USA
| | - Corinne N Riggin
- Department of Bioengineering, University of Pennsylvania, Philadelphia, PA, USA
| | - Sijia Zhang
- Department of Bioengineering, University of Pennsylvania, Philadelphia, PA, USA
| | - Philip G Haines
- Division of Cardiovascular Medicine, University of Pennsylvania, Philadelphia, PA, USA
| | - Katy L Ong
- Department of Cell and Developmental Biology, University of Pennsylvania, Philadelphia, PA, USA
| | - Paul A Janmey
- Department of Bioengineering, University of Pennsylvania, Philadelphia, PA, USA; Department of Physiology, University of Pennsylvania, Philadelphia, PA, USA.
| |
Collapse
|
29
|
Thorpe CT, Godinho MSC, Riley GP, Birch HL, Clegg PD, Screen HRC. The interfascicular matrix enables fascicle sliding and recovery in tendon, and behaves more elastically in energy storing tendons. J Mech Behav Biomed Mater 2015; 52:85-94. [PMID: 25958330 PMCID: PMC4655227 DOI: 10.1016/j.jmbbm.2015.04.009] [Citation(s) in RCA: 94] [Impact Index Per Article: 10.4] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/24/2014] [Revised: 02/27/2015] [Accepted: 04/07/2015] [Indexed: 11/23/2022]
Abstract
While the predominant function of all tendons is to transfer force from muscle to bone and position the limbs, some tendons additionally function as energy stores, reducing the cost of locomotion. Energy storing tendons experience extremely high strains and need to be able to recoil efficiently for maximum energy storage and return. In the equine forelimb, the energy storing superficial digital flexor tendon (SDFT) has much higher failure strains than the positional common digital extensor tendon (CDET). However, we have previously shown that this is not due to differences in the properties of the SDFT and CDET fascicles (the largest tendon subunits). Instead, there is a greater capacity for interfascicular sliding in the SDFT which facilitates the greater extensions in this particular tendon (Thorpe et al., 2012). In the current study, we exposed fascicles and interfascicular matrix (IFM) from the SDFT and CDET to cyclic loading followed by a test to failure. The results show that IFM mechanical behaviour is not a result of irreversible deformation, but the IFM is able to withstand cyclic loading, and is more elastic in the SDFT than in the CDET. We also assessed the effect of ageing on IFM properties, demonstrating that the IFM is less able to resist repetitive loading as it ages, becoming stiffer with increasing age in the SDFT. These results provide further indications that the IFM is important for efficient function in energy storing tendons, and age-related alterations to the IFM may compromise function and predispose older tendons to injury. Fascicle sliding enables high levels of extension in energy storing tendons. Sliding mechanics are governed by the interfascicular matrix (IFM). We assessed IFM extension and recovery. IFM elasticity and recovery are greater in energy storing tendons. The IFM plays an important role in the function of energy storing tendons.
Collapse
Affiliation(s)
- Chavaunne T Thorpe
- Institute of Bioengineering, School of Engineering and Materials Science, Queen Mary University of London, Mile End Road, London E1 4NS UK.
| | - Marta S C Godinho
- Institute of Bioengineering, School of Engineering and Materials Science, Queen Mary University of London, Mile End Road, London E1 4NS UK
| | - Graham P Riley
- School of Biological Sciences, University of East Anglia, Norwich Research Park, Norwich NR4 7TJ, UK
| | - Helen L Birch
- Institute of Orthopaedics and Musculoskeletal Science, University College London, Royal National Orthopaedic Hospital, Stanmore HA7 4LP, UK
| | - Peter D Clegg
- Department of Musculoskeletal Biology, Institute of Ageing and Chronic Disease, University of Liverpool, Leahurst Campus, Neston CH64 7TE, UK
| | - Hazel R C Screen
- Institute of Bioengineering, School of Engineering and Materials Science, Queen Mary University of London, Mile End Road, London E1 4NS UK
| |
Collapse
|
30
|
Kondratko-Mittnacht J, Duenwald-Kuehl S, Lakes R, Vanderby R. Shear load transfer in high and low stress tendons. J Mech Behav Biomed Mater 2015; 45:109-20. [PMID: 25700261 DOI: 10.1016/j.jmbbm.2015.01.021] [Citation(s) in RCA: 13] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/01/2014] [Revised: 01/14/2015] [Accepted: 01/29/2015] [Indexed: 10/24/2022]
Abstract
BACKGROUND Tendon is an integral part of joint movement and stability, as it functions to transmit load from muscle to bone. It has an anisotropic, fibrous hierarchical structure that is generally loaded in the direction of its fibers/fascicles. Internal load distributions are altered when joint motion rotates an insertion site or when local damage disrupts fibers/fascicles, potentially causing inter-fiber (or inter-fascicular) shear. Tendons with different microstructures (helical versus linear) may redistribute loads differently. METHOD OF APPROACH This study explored how shear redistributes axial loads in rat tail tendon (low stress tendons with linear microstructure) and porcine flexor tendon (high stress with helical microstructure) by creating lacerations on opposite sides of the tendon, ranging from about 20% to 60% of the tendon width, to create various magnitudes of shear. Differences in fascicular orientation were quantified using polarized light microscopy. RESULTS AND CONCLUSIONS Unexpectedly, both tendon types maintained about 20% of pre-laceration stress values after overlapping cuts of 60% of tendon width (no intact fibers end to end) suggesting that shear stress transfer can contribute more to overall tendon strength and stiffness than previously reported. All structural parameters for both tendon types decreased linearly with increasing laceration depth. The tail tendon had a more rapid decline in post-laceration elastic stress and modulus parameters as well as a more linear and less tightly packed fascicular structure, suggesting that positional tendons may be less well suited to redistribute loads via a shear mechanism.
Collapse
Affiliation(s)
- Jaclyn Kondratko-Mittnacht
- Department of Biomedical Engineering, University of Wisconsin-Madison, Madison, WI 53705, USA; Department of Orthopedics and Rehabilitation, University of Wisconsin-Madison, Madison, WI 53705, USA
| | - Sarah Duenwald-Kuehl
- Department of Biomedical Engineering, University of Wisconsin-Madison, Madison, WI 53705, USA; Department of Orthopedics and Rehabilitation, University of Wisconsin-Madison, Madison, WI 53705, USA
| | - Roderic Lakes
- Materials Science Program, University of Wisconsin-Madison, Madison, WI 53705, USA; Department of Engineering Physics, University of Wisconsin-Madison, Madison, WI 53705, USA
| | - Ray Vanderby
- Department of Biomedical Engineering, University of Wisconsin-Madison, Madison, WI 53705, USA; Department of Orthopedics and Rehabilitation, University of Wisconsin-Madison, Madison, WI 53705, USA; Materials Science Program, University of Wisconsin-Madison, Madison, WI 53705, USA.
| |
Collapse
|
31
|
Shepherd JH, Riley GP, Screen HRC. Early stage fatigue damage occurs in bovine tendon fascicles in the absence of changes in mechanics at either the gross or micro-structural level. J Mech Behav Biomed Mater 2014; 38:163-72. [PMID: 25001495 PMCID: PMC4148183 DOI: 10.1016/j.jmbbm.2014.06.005] [Citation(s) in RCA: 21] [Impact Index Per Article: 2.1] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/10/2014] [Revised: 06/01/2014] [Accepted: 06/04/2014] [Indexed: 12/04/2022]
Abstract
Many tendon injuries are believed to result from repetitive motion or overuse, leading to the accumulation of micro-damage over time. In vitro fatigue loading can be used to characterise damage during repeated use and investigate how this may relate to the aetiology of tendinopathy. This study considered the effect of fatigue loading on fascicles from two functionally distinct bovine tendons: the digital extensor and deep digital flexor. Micro-scale extension mechanisms were investigated in fascicles before or after a period of cyclic creep loading, comparing two different measurement techniques – the displacement of a photo-bleached grid and the use of nuclei as fiducial markers. Whilst visual damage was clearly identified after only 300 cycles of creep loading, these visual changes did not affect either gross fascicle mechanics or fascicle microstructural extension mechanisms over the 900 fatigue cycles investigated. However, significantly greater fibre sliding was measured when observing grid deformation rather than the analysis of nuclei movement. Measurement of microstructural extension with both techniques was localised and this may explain the absence of change in microstructural deformation in response to fatigue loading. Alternatively, the data may demonstrate that fascicles can withstand a degree of matrix disruption with no impact on mechanics. Whilst use of a photo-bleached grid to directly measure the collagen is the best indicator of matrix deformation, nuclei tracking may provide a better measure of the strain perceived directly by the cells. Tendon fascicle gross mechanics and micro-scale deformation investigated after fatigue loading. Fascicles can withstand a degree of matrix disruption without impact on mechanics. More fibre sliding was observed measuring grid deformation than tracking nuclei. Nuclei tracking may better represent the strains experienced by cells than grid deformation.
Collapse
Affiliation(s)
- Jennifer H Shepherd
- Institute of Bioengineering, School of Engineering and Materials Science, Queen Mary, University of London, Mile End Road, E1 4NS, UK
| | - Graham P Riley
- School of Biological Sciences, University of East Anglia, UK
| | - Hazel R C Screen
- Institute of Bioengineering, School of Engineering and Materials Science, Queen Mary, University of London, Mile End Road, E1 4NS, UK.
| |
Collapse
|