1
|
Parag AK, Raducanu BC, Erden OK, Stanzione S, Beutel F, Pendse C, Van Hoof C, Van Helleputte N, Gielen G. Dynamic Sub-Array Selection-Based Energy-Efficient Localization and Tracking Method to Power Implanted Medical Devices in Scattering Heterogenous Media Employing Ultrasound. IEEE TRANSACTIONS ON BIOMEDICAL CIRCUITS AND SYSTEMS 2025; 19:657-668. [PMID: 39495684 DOI: 10.1109/tbcas.2024.3487782] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/06/2024]
Abstract
Ultrasound (US) as a wireless power transfer methodology has drawn considerable attention from the implantable medical devices (IMD) research community. Beamforming (BF) using an external transducer array patch (ETAP) has been proposed as a robust localization scheme to find a mm-sized IMD inside the human body. However, for applications focusing on deep and shallow IMDs, optimum resource utilization at the ETAP is a major power efficiency concern for energy-constrained wearable patches. Moreover, misalignment tolerance due to IMD movements (respiratory and patient ambulatory reasons) relative to the ETAP remains a challenge. This paper presents an energy-efficient method to localize a mm-sized IMD through the dynamic selection of a sub-array within the ETAP. It is fully adaptive to the heterogeneity of the media and requires no a priori knowledge of the IMD. To improve the tolerance to IMD movements, tracking is implemented by adding and subtracting elements on the sub-array such that the sub-array electrically follows the IMD movement. Furthermore, it is shown that a minimum sampling frequency of 10X the US frequency can improve the tolerance to random noise. K-wave simulations in MATLAB are performed in different heterogenous, scattering biological media to prove the efficacy of the proposed method over standard BF methods. Measurement results in heterogenous scattering media consisting of a 3D-printed human ribs phantom and a partially blocking multipath cancellous bone phantom show an energy efficiency improvement of 10.53X and 14.4X compared to the delay-and-sum beamforming method and the unfocused transmission employing all the elements of the ETAP, respectively.
Collapse
|
2
|
Nanbakhsh K, Van Gompel M, Ritasalo R, Gollhardt A, Horváth D, Tóth K, Meszéna D, Ulbert I, Serdijn W, Giagka V. An In Vivo Biostability Evaluation of ALD and Parylene-ALD Multilayers as Micro-Packaging Solutions for Small Single-Chip Implants. SMALL (WEINHEIM AN DER BERGSTRASSE, GERMANY) 2025; 21:e2410141. [PMID: 39846830 PMCID: PMC12019904 DOI: 10.1002/smll.202410141] [Citation(s) in RCA: 1] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 10/29/2024] [Revised: 01/09/2025] [Indexed: 01/24/2025]
Abstract
Miniaturization of next-generation active neural implants requires novel micro-packaging solutions that can maintain their long-term coating performance in the body. This work presents two thin-film coatings and evaluates their biostability and in vivo performance over a 7-month animal study. To evaluate the coatings on representative surfaces, two silicon microchips with different surface microtopography are used. Microchips are coated with either a ≈100 nm thick inorganic hafnium-based multilayer deposited via atomic layer deposition (ALD-ML), or a ≈6 µm thick hybrid organic-inorganic Parylene C and titanium-based ALD multilayer stack (ParC-ALD-ML). After 7 months of direct exposure to the body environment, the multilayer coatings are evaluated using optical and cross-sectional scanning electron microscopy. Time-of-flight secondary ion mass spectrometry (ToF-SIMS) is also used to evaluate the chemical stability and barrier performance of the layers after long-term exposure to body media. Results showed the excellent biostability of the 100 nm ALD-ML coating with no ionic penetration within the layer. For the ParC-ALD-ML, concurrent surface degradation and ion ingress are detected within the top ≈70 nm of the outer Parylene C layer. The results and evaluation techniques presented here can enable future material selection, packaging, and analysis, enhancing the functional stability of future chip-embedded neural implants.
Collapse
Affiliation(s)
- Kambiz Nanbakhsh
- Department of MicroelectronicsFaculty of Electrical EngineeringMathematics and Computer ScienceDelft University of TechnologyDelft2628 CNThe Netherlands
| | | | - Riina Ritasalo
- Applied Materials, FinlandMasalantie 365Masala02430Finland
| | - Astrid Gollhardt
- Department of Environmental & Reliability EngineeringFraunhofer Institute for Reliability and Microintegration IZM13355BerlinGermany
| | - Domonkos Horváth
- Research Centre for Natural SciencesInstitute of Cognitive Neuroscience and PsychologyHUN‐RENBudapest1117Hungary
- Faculty of Information Technology and BionicsPazmany Peter Catholic UniversityBudapest1083Hungary
| | - Kinga Tóth
- Research Centre for Natural SciencesInstitute of Cognitive Neuroscience and PsychologyHUN‐RENBudapest1117Hungary
| | - Domokos Meszéna
- Research Centre for Natural SciencesInstitute of Cognitive Neuroscience and PsychologyHUN‐RENBudapest1117Hungary
- Faculty of Information Technology and BionicsPazmany Peter Catholic UniversityBudapest1083Hungary
| | - István Ulbert
- Research Centre for Natural SciencesInstitute of Cognitive Neuroscience and PsychologyHUN‐RENBudapest1117Hungary
- Faculty of Information Technology and BionicsPazmany Peter Catholic UniversityBudapest1083Hungary
- Department of Neurosurgery and NeurointerventionFaculty of MedicineSemmelweis UniversityAmerikai út 57Budapest1145Hungary
| | - Wouter Serdijn
- Department of MicroelectronicsFaculty of Electrical EngineeringMathematics and Computer ScienceDelft University of TechnologyDelft2628 CNThe Netherlands
- Department of Neuroscience Erasmus Medical CenterRotterdam3015 GDThe Netherlands
| | - Vasiliki Giagka
- Department of MicroelectronicsFaculty of Electrical EngineeringMathematics and Computer ScienceDelft University of TechnologyDelft2628 CNThe Netherlands
- Department of System Integration and Interconnection TechnologiesFraunhofer Institute for Reliability and Microintegration IZM13355BerlinGermany
| |
Collapse
|
3
|
Nanbakhsh K, Shah Idil A, Lamont C, Dücső C, Akgun ÖC, Horváth D, Tóth K, Meszéna D, Ulbert I, Mazza F, Constandinou TG, Serdijn W, Vanhoestenberghe A, Donaldson N, Giagka V. On the longevity and inherent hermeticity of silicon-ICs: evaluation of bare-die and PDMS-coated ICs after accelerated aging and implantation studies. Nat Commun 2025; 16:12. [PMID: 39746983 PMCID: PMC11697292 DOI: 10.1038/s41467-024-55298-4] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/10/2024] [Accepted: 12/06/2024] [Indexed: 01/04/2025] Open
Abstract
Silicon integrated circuits (ICs) are central to the next-generation miniature active neural implants, whether packaged in soft polymers for flexible bioelectronics or implanted as bare die for neural probes. These emerging applications bring the IC closer to the corrosive body environment, raising reliability concerns, particularly for chronic use. Here, we evaluate the inherent hermeticity of bare die ICs, and examine the potential of polydimethylsiloxane (PDMS), a moisture-permeable elastomer, as a standalone encapsulation material. For this aim, the electrical and material performance of ICs sourced from two foundries was evaluated through one-year accelerated in vitro and in vivo studies. ICs featured custom-designed test structures and were partially PDMS coated, creating two regions on each chip, uncoated "bare die" and "PDMS-coated". During the accelerated in vitro study, ICs were electrically biased and periodically monitored. Results revealed stable electrical performance, indicating the unaffected operation of ICs even when directly exposed to physiological fluids. Despite this, material analysis revealed IC degradation in the bare regions. PDMS-coated regions, however, revealed limited degradation, making PDMS a suitable IC encapsulant for years-long implantation. Based on the new insights, guidelines are proposed that may enhance the longevity of implantable ICs, broadening their applications in the biomedical field.
Collapse
Affiliation(s)
- Kambiz Nanbakhsh
- Department of Microelectronics, Faculty of Electrical Engineering, Mathematics and Computer Science, Delft University of Technology, Delft, The Netherlands
| | - Ahmad Shah Idil
- Department of Medical Physics and Biomedical Engineering, University College London, London, UK
- Department of Electrical & Electronic Engineering, Imperial College London, London, UK
- UK Dementia Research Institute, Care Research and Technology Centre, London, UK
- Mint Neurotechnologies Ltd, London, UK
| | - Callum Lamont
- Department of Medical Physics and Biomedical Engineering, University College London, London, UK
| | - Csaba Dücső
- Centre for Energy Research, HUN-REN, Budapest, Hungary
| | - Ömer Can Akgun
- Department of Microelectronics, Faculty of Electrical Engineering, Mathematics and Computer Science, Delft University of Technology, Delft, The Netherlands
- Nikhef - Dutch National Institute for Subatomic Physics, Amsterdam, the Netherlands
| | - Domonkos Horváth
- Research Centre for Natural Sciences, Institute of Cognitive Neuroscience and Psychology, HUN-REN, Budapest, Hungary
- Pazmany Peter Catholic University, Faculty of Information Technology and Bionics, Budapest, Hungary
| | - Kinga Tóth
- Research Centre for Natural Sciences, Institute of Cognitive Neuroscience and Psychology, HUN-REN, Budapest, Hungary
- Pazmany Peter Catholic University, Faculty of Information Technology and Bionics, Budapest, Hungary
| | - Domokos Meszéna
- Research Centre for Natural Sciences, Institute of Cognitive Neuroscience and Psychology, HUN-REN, Budapest, Hungary
- Pazmany Peter Catholic University, Faculty of Information Technology and Bionics, Budapest, Hungary
| | - István Ulbert
- Research Centre for Natural Sciences, Institute of Cognitive Neuroscience and Psychology, HUN-REN, Budapest, Hungary
- Pazmany Peter Catholic University, Faculty of Information Technology and Bionics, Budapest, Hungary
| | - Federico Mazza
- Department of Electrical & Electronic Engineering, Imperial College London, London, UK
| | - Timothy G Constandinou
- Department of Electrical & Electronic Engineering, Imperial College London, London, UK
- UK Dementia Research Institute, Care Research and Technology Centre, London, UK
- Mint Neurotechnologies Ltd, London, UK
| | - Wouter Serdijn
- Department of Microelectronics, Faculty of Electrical Engineering, Mathematics and Computer Science, Delft University of Technology, Delft, The Netherlands
- Department of Neuroscience, Erasmus Medical Center, Rotterdam, The Netherlands
| | - Anne Vanhoestenberghe
- Department of Medical Physics and Biomedical Engineering, University College London, London, UK
- School of Biomedical Engineering & Imaging Sciences, King's College London, London, UK
| | - Nick Donaldson
- Department of Medical Physics and Biomedical Engineering, University College London, London, UK
| | - Vasiliki Giagka
- Department of Microelectronics, Faculty of Electrical Engineering, Mathematics and Computer Science, Delft University of Technology, Delft, The Netherlands.
- Department of System Integration and Interconnection Technologies, Fraunhofer Institute for Reliability and Microintegration IZM, Berlin, Germany.
| |
Collapse
|
4
|
Holzapfel L, Giagka V. A Robust Backscatter Modulation Scheme for Uninterrupted Ultrasonic Powering and Back-Communication of Deep Implants. IEEE TRANSACTIONS ON ULTRASONICS, FERROELECTRICS, AND FREQUENCY CONTROL 2024; 71:1897-1905. [PMID: 39302785 DOI: 10.1109/tuffc.2024.3465268] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 09/22/2024]
Abstract
Traditionally, implants are powered by batteries, which have to be recharged by an inductive power link. In the recent years, ultrasonic power links are being investigated, promising more available power for deeply implanted miniaturized devices. These implants often need to transfer back information. For ultrasonically powered implants, this is usually achieved with on-off keying (OOK) based on backscatter modulation, or active driving of a secondary transducer. In this article, we propose to superimpose subcarriers, effectively leveraging frequency-shift keying (FSK), which increases the robustness of the link against interference and fading. It also allows for simultaneous powering and communication, and inherently provides the possibility of frequency domain multiplexing for implant networks. The modulation scheme can be implemented in miniaturized application-specific integrated circuits (ASICs), field programmable gate arrays (FPGAs), and microcontrollers. We have validated this modulation scheme in a water tank during continuous ultrasound and movement. We achieved symbol rates of up to 104 kBd, and were able to transfer data through 20 cm of water and through a 5 cm tissue phantom with additional misalignment and during movements. This approach could provide a robust uplink for miniaturized implants that are located deep inside the body and need continuous ultrasonic powering.
Collapse
|
5
|
Thota AK, Jung R. Accelerating neurotechnology development using an Agile methodology. Front Neurosci 2024; 18:1328540. [PMID: 38435056 PMCID: PMC10904481 DOI: 10.3389/fnins.2024.1328540] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/26/2023] [Accepted: 01/18/2024] [Indexed: 03/05/2024] Open
Abstract
Novel bioelectronic medical devices that target neural control of visceral organs (e.g., liver, gut, spleen) or inflammatory reflex pathways are innovative class III medical devices like implantable cardiac pacemakers that are lifesaving and life-sustaining medical devices. Bringing innovative neurotechnologies early into the market and the hands of treatment providers would benefit a large population of patients inflicted with autonomic and chronic immune disorders. Medical device manufacturers and software developers widely use the Waterfall methodology to implement design controls through verification and validation. In the Waterfall methodology, after identifying user needs, a functional unit is fabricated following the verification loop (design, build, and verify) and then validated against user needs. Considerable time can lapse in building, verifying, and validating the product because this methodology has limitations for adjusting to unanticipated changes. The time lost in device development can cause significant delays in final production, increase costs, and may even result in the abandonment of the device development. Software developers have successfully implemented an Agile methodology that overcomes these limitations in developing medical software. However, Agile methodology is not routinely used to develop medical devices with implantable hardware because of the increased regulatory burden of the need to conduct animal and human studies. Here, we provide the pros and cons of the Waterfall methodology and make a case for adopting the Agile methodology in developing medical devices with physical components. We utilize a peripheral nerve interface as an example device to illustrate the use of the Agile approach to develop neurotechnologies.
Collapse
Affiliation(s)
- Anil Kumar Thota
- Adaptive Neural Systems Group, The Institute for Integrative and Innovative Research, University of Arkansas, Fayetteville, AR, United States
| | - Ranu Jung
- Adaptive Neural Systems Group, The Institute for Integrative and Innovative Research, University of Arkansas, Fayetteville, AR, United States
- Biomedical Engineering Department, University of Arkansas, Fayetteville, AR, United States
| |
Collapse
|
6
|
Bakhshaee Babaroud N, Rice SJ, Camarena Perez M, Serdijn WA, Vollebregt S, Giagka V. Surface modification of multilayer graphene electrodes by local printing of platinum nanoparticles using spark ablation for neural interfacing. NANOSCALE 2024; 16:3549-3559. [PMID: 38287770 DOI: 10.1039/d3nr05523j] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 01/31/2024]
Abstract
In this paper, we present the surface modification of multilayer graphene electrodes with platinum (Pt) nanoparticles (NPs) using spark ablation. This method yields an individually selective local printing of NPs on an electrode surface at room temperature in a dry process. NP printing is performed as a post-process step to enhance the electrochemical characteristics of graphene electrodes. The NP-printed electrode shows significant improvements in impedance, charge storage capacity (CSC), and charge injection capacity (CIC), versus the equivalent electrodes without NPs. Specifically, electrodes with 40% NP surface density demonstrate 4.5 times lower impedance, 15 times higher CSC, and 4 times better CIC. Electrochemical stability, assessed via continuous cyclic voltammetry (CV) and voltage transient (VT) tests, indicated minimal deviations from the initial performance, while mechanical stability, assessed via ultrasonic vibration, is also improved after the NP printing. Importantly, NP surface densities up to 40% maintain the electrode optical transparency required for compatibility with optical imaging and optogenetics. These results demonstrate selective NP deposition and local modification of electrochemical properties in graphene electrodes for the first time, enabling the cohabitation of graphene electrodes with different electrochemical and optical characteristics on the same substrate for neural interfacing.
Collapse
Affiliation(s)
- Nasim Bakhshaee Babaroud
- Department of Microelectronics, Faculty of Electrical Engineering, Mathematics and Computer Science, Delft University of Technology, Delft, The Netherlands.
| | - Samantha J Rice
- Department of Microelectronics, Faculty of Electrical Engineering, Mathematics and Computer Science, Delft University of Technology, Delft, The Netherlands.
| | - Maria Camarena Perez
- Department of Microelectronics, Faculty of Electrical Engineering, Mathematics and Computer Science, Delft University of Technology, Delft, The Netherlands.
| | - Wouter A Serdijn
- Department of Microelectronics, Faculty of Electrical Engineering, Mathematics and Computer Science, Delft University of Technology, Delft, The Netherlands.
- Erasmus University Medical Center (Erasmus MC), Rotterdam, The Netherlands
| | - Sten Vollebregt
- Department of Microelectronics, Faculty of Electrical Engineering, Mathematics and Computer Science, Delft University of Technology, Delft, The Netherlands.
| | - Vasiliki Giagka
- Department of Microelectronics, Faculty of Electrical Engineering, Mathematics and Computer Science, Delft University of Technology, Delft, The Netherlands.
- Technologies for Bioelectronics Group, Department of System Integration and Interconnection Technologies, Fraunhofer Institute for Reliability and Micro-integration IZM, Berlin, Germany.
| |
Collapse
|
7
|
Taghlabi KM, Cruz-Garza JG, Hassan T, Potnis O, Bhenderu LS, Guerrero JR, Whitehead RE, Wu Y, Luan L, Xie C, Robinson JT, Faraji AH. Clinical outcomes of peripheral nerve interfaces for rehabilitation in paralysis and amputation: a literature review. J Neural Eng 2024; 21:011001. [PMID: 38237175 DOI: 10.1088/1741-2552/ad200f] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/03/2023] [Accepted: 01/18/2024] [Indexed: 02/02/2024]
Abstract
Peripheral nerve interfaces (PNIs) are electrical systems designed to integrate with peripheral nerves in patients, such as following central nervous system (CNS) injuries to augment or replace CNS control and restore function. We review the literature for clinical trials and studies containing clinical outcome measures to explore the utility of human applications of PNIs. We discuss the various types of electrodes currently used for PNI systems and their functionalities and limitations. We discuss important design characteristics of PNI systems, including biocompatibility, resolution and specificity, efficacy, and longevity, to highlight their importance in the current and future development of PNIs. The clinical outcomes of PNI systems are also discussed. Finally, we review relevant PNI clinical trials that were conducted, up to the present date, to restore the sensory and motor function of upper or lower limbs in amputees, spinal cord injury patients, or intact individuals and describe their significant findings. This review highlights the current progress in the field of PNIs and serves as a foundation for future development and application of PNI systems.
Collapse
Affiliation(s)
- Khaled M Taghlabi
- Department of Neurological Surgery, Houston Methodist Hospital, Houston, TX 77030, United States of America
- Center for Neural Systems Restoration, Houston Methodist Research Institute, Houston, TX 77030, United States of America
- Clinical Innovations Laboratory, Houston Methodist Research Institute, Houston, TX 77030, United States of America
| | - Jesus G Cruz-Garza
- Department of Neurological Surgery, Houston Methodist Hospital, Houston, TX 77030, United States of America
- Center for Neural Systems Restoration, Houston Methodist Research Institute, Houston, TX 77030, United States of America
- Clinical Innovations Laboratory, Houston Methodist Research Institute, Houston, TX 77030, United States of America
| | - Taimur Hassan
- Department of Neurological Surgery, Houston Methodist Hospital, Houston, TX 77030, United States of America
- Center for Neural Systems Restoration, Houston Methodist Research Institute, Houston, TX 77030, United States of America
- Clinical Innovations Laboratory, Houston Methodist Research Institute, Houston, TX 77030, United States of America
- School of Medicine, Texas A&M University, Bryan, TX 77807, United States of America
| | - Ojas Potnis
- Department of Neurological Surgery, Houston Methodist Hospital, Houston, TX 77030, United States of America
- Center for Neural Systems Restoration, Houston Methodist Research Institute, Houston, TX 77030, United States of America
- Clinical Innovations Laboratory, Houston Methodist Research Institute, Houston, TX 77030, United States of America
- School of Engineering Medicine, Texas A&M University, Houston, TX 77030, United States of America
| | - Lokeshwar S Bhenderu
- Department of Neurological Surgery, Houston Methodist Hospital, Houston, TX 77030, United States of America
- Center for Neural Systems Restoration, Houston Methodist Research Institute, Houston, TX 77030, United States of America
- Clinical Innovations Laboratory, Houston Methodist Research Institute, Houston, TX 77030, United States of America
- School of Medicine, Texas A&M University, Bryan, TX 77807, United States of America
| | - Jaime R Guerrero
- Department of Neurological Surgery, Houston Methodist Hospital, Houston, TX 77030, United States of America
- Center for Neural Systems Restoration, Houston Methodist Research Institute, Houston, TX 77030, United States of America
- Clinical Innovations Laboratory, Houston Methodist Research Institute, Houston, TX 77030, United States of America
| | - Rachael E Whitehead
- Department of Academic Affairs, Houston Methodist Academic Institute, Houston, TX 77030, United States of America
| | - Yu Wu
- Rice Neuroengineering Initiative, Rice University, Houston, TX 77005, United States of America
- Department of Electrical and Computer Engineering, Rice University, Houston, TX 77005, United States of America
| | - Lan Luan
- Rice Neuroengineering Initiative, Rice University, Houston, TX 77005, United States of America
- Department of Electrical and Computer Engineering, Rice University, Houston, TX 77005, United States of America
| | - Chong Xie
- Rice Neuroengineering Initiative, Rice University, Houston, TX 77005, United States of America
- Department of Electrical and Computer Engineering, Rice University, Houston, TX 77005, United States of America
| | - Jacob T Robinson
- Rice Neuroengineering Initiative, Rice University, Houston, TX 77005, United States of America
- Department of Electrical and Computer Engineering, Rice University, Houston, TX 77005, United States of America
| | - Amir H Faraji
- Department of Neurological Surgery, Houston Methodist Hospital, Houston, TX 77030, United States of America
- Center for Neural Systems Restoration, Houston Methodist Research Institute, Houston, TX 77030, United States of America
- Clinical Innovations Laboratory, Houston Methodist Research Institute, Houston, TX 77030, United States of America
- Rice Neuroengineering Initiative, Rice University, Houston, TX 77005, United States of America
- Department of Electrical and Computer Engineering, Rice University, Houston, TX 77005, United States of America
| |
Collapse
|
8
|
Das S, Ghosh B, Sahoo RN, Nayak AK. Recent Advancements in Bioelectronic Medicine: A Review. Curr Drug Deliv 2024; 21:1445-1459. [PMID: 38173212 DOI: 10.2174/0115672018286832231218112557] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/11/2023] [Revised: 11/17/2023] [Accepted: 12/04/2023] [Indexed: 01/05/2024]
Abstract
Bioelectronic medicine is a multidisciplinary field that combines molecular medicine, neurology, engineering, and computer science to design devices for diagnosing and treating diseases. The advancements in bioelectronic medicine can improve the precision and personalization of illness treatment. Bioelectronic medicine can produce, suppress, and measure electrical activity in excitable tissue. Bioelectronic devices modify specific neural circuits using electrons rather than pharmaceuticals and uses of bioelectronic processes to regulate the biological processes underlining various diseases. This promotes the potential to address the underlying causes of illnesses, reduce adverse effects, and lower costs compared to conventional medication. The current review presents different important aspects of bioelectronic medicines with recent advancements. The area of bioelectronic medicine has a lot of potential for treating diseases, enabling non-invasive therapeutic intervention by regulating brain impulses. Bioelectronic medicine uses electricity to control biological processes, treat illnesses, or regain lost capability. These new classes of medicines are designed by the technological developments in the detection and regulation of electrical signaling methods in the nervous system. Peripheral nervous system regulates a wide range of processes in chronic diseases; it involves implanting small devices onto specific peripheral nerves, which read and regulate the brain signaling patterns to achieve therapeutic effects specific to the signal capacity of a particular organ. The potential for bioelectronic medicine field is vast, as it investigates for treatment of various diseases, including rheumatoid arthritis, diabetes, hypertension, paralysis, chronic illnesses, blindness, etc.
Collapse
Affiliation(s)
- Sudipta Das
- Department of Pharmaceutics, Netaji Subhas Chandra Bose Institute of Pharmacy, Chakdaha, Nadia - 741222, West Bengal, India
| | - Baishali Ghosh
- Department of Pharmaceutics, Netaji Subhas Chandra Bose Institute of Pharmacy, Chakdaha, Nadia - 741222, West Bengal, India
| | - Rudra Narayan Sahoo
- Department of Pharmaceutics, School of Pharmaceutical Sciences, Siksha 'O' Anusandhan (Deemed to be University), Bhubaneswar, 751003, Odisha, India
| | - Amit Kumar Nayak
- Department of Pharmaceutics, School of Pharmaceutical Sciences, Siksha 'O' Anusandhan (Deemed to be University), Bhubaneswar, 751003, Odisha, India
| |
Collapse
|
9
|
Velea AI, Wilson J, Gollhardt A, Karuthedath CB, Thanniyil AS, Giagka V. Non-monolithic fabrication of thin-film microelectrode arrays on PMUT transducers as a bimodal neuroscientific investigation tool . ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY. IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY. ANNUAL INTERNATIONAL CONFERENCE 2023; 2023:1-4. [PMID: 38082912 DOI: 10.1109/embc40787.2023.10340770] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 12/18/2023]
Abstract
Ultrasound (US)-based neuromodulation has recently emerged as a spatially selective yet non-invasive alternative to conventional electrically-based neural interfaces. However, the fundamental mechanisms of US neuromodulation are not yet clarified. Thus, there is a need for in-vitro bimodal investigation tools that allow us to compare the effect of US versus electrically-induced neural activity in the vicinity of the transducing element. To this end, we propose a MicroElectrode-MicroTransducer Array (MEMTA), where a dense array of electrodes is co-fabricated on top of a similarly dense array of US transducers.In this paper, we test the proof of concept for such co-fabrication using a non-monolithic approach, where, at its most challenging scenario, desired topologies require electrodes to be formed directly on top of fragile piezoelectric micromachined ultrasound transducer (PMUTs) membranes. On top of the PMUTs, a thin-film microelectrode array was developed utilizing microfabrication processes, including metal sputtering, lithography, etching and soft encapsulation. The samples were analysed through focused ion beam-scanning electron microscopy (FIB-SEM), and the results have shown that damage to the membranes does not occur during any of the process steps. This paper proves that the non-monolithic development of a miniaturised bimodal neuroscientific investigation tool can be achieved, thus, opening up a series of possibilities for further understanding and investigation of the nervous system.
Collapse
|
10
|
Panskus R, Holzapfel L, Serdijn WA, Giagka V. On the Stimulation Artifact Reduction during Electrophysiological Recording of Compound Nerve Action Potentials . ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY. IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY. ANNUAL INTERNATIONAL CONFERENCE 2023; 2023:1-5. [PMID: 38083005 DOI: 10.1109/embc40787.2023.10341179] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 12/18/2023]
Abstract
Recording neuronal activity triggered by electrical impulses is a powerful tool in neuroscience research and neural engineering. It is often applied in acute electrophysiological experimental settings to record compound nerve action potentials. However, the elicited neural response is often distorted by electrical stimulus artifacts, complicating subsequent analysis. In this work, we present a model to better understand the effect of the selected amplifier configuration and the location of the ground electrode in a practical electrophysiological nerve setup. Simulation results show that the stimulus artifact can be reduced by more than an order of magnitude if the placement of the ground electrode, its impedance, and the amplifier configuration are optimized. We experimentally demonstrate the effects in three different settings, in-vivo and in-vitro.
Collapse
|
11
|
Donahue MJ, Ejneby MS, Jakešová M, Caravaca AS, Andersson G, Sahalianov I, Đerek V, Hult H, Olofsson PS, Głowacki ED. Wireless optoelectronic devices for vagus nerve stimulation in mice. J Neural Eng 2022; 19. [PMID: 36356313 DOI: 10.1088/1741-2552/aca1e3] [Citation(s) in RCA: 10] [Impact Index Per Article: 3.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/27/2022] [Accepted: 11/10/2022] [Indexed: 11/12/2022]
Abstract
Objective.Vagus nerve stimulation (VNS) is a promising approach for the treatment of a wide variety of debilitating conditions, including autoimmune diseases and intractable epilepsy. Much remains to be learned about the molecular mechanisms involved in vagus nerve regulation of organ function. Despite an abundance of well-characterized rodent models of common chronic diseases, currently available technologies are rarely suitable for the required long-term experiments in freely moving animals, particularly experimental mice. Due to challenging anatomical limitations, many relevant experiments require miniaturized, less invasive, and wireless devices for precise stimulation of the vagus nerve and other peripheral nerves of interest. Our objective is to outline possible solutions to this problem by using nongenetic light-based stimulation.Approach.We describe how to design and benchmark new microstimulation devices that are based on transcutaneous photovoltaic stimulation. The approach is to use wired multielectrode cuffs to test different stimulation patterns, and then build photovoltaic stimulators to generate the most optimal patterns. We validate stimulation through heart rate analysis.Main results.A range of different stimulation geometries are explored with large differences in performance. Two types of photovoltaic devices are fabricated to deliver stimulation: photocapacitors and photovoltaic flags. The former is simple and more compact, but has limited efficiency. The photovoltaic flag approach is more elaborate, but highly efficient. Both can be used for wireless actuation of the vagus nerve using light impulses.Significance.These approaches can enable studies in small animals that were previously challenging, such as long-termin vivostudies for mapping functional vagus nerve innervation. This new knowledge may have potential to support clinical translation of VNS for treatment of select inflammatory and neurologic diseases.
Collapse
Affiliation(s)
- Mary J Donahue
- Laboratory of Organic Electronics, Campus Norrköping, Linköping University, SE-60174 Norrköping, Sweden
| | - Malin Silverå Ejneby
- Laboratory of Organic Electronics, Campus Norrköping, Linköping University, SE-60174 Norrköping, Sweden.,Wallenberg Centre for Molecular Medicine, Linköping University, SE-58185 Linköping, Sweden
| | - Marie Jakešová
- Bioelectronics Materials and Devices Laboratory, Central European Institute of Technology, Brno University of Technology, Purkyňova 123, 61200 Brno, Czech Republic
| | - April S Caravaca
- Laboratory of Immunobiology, Center for Bioelectronic Medicine, Department of Medicine, Center for Molecular Medicine, Karolinska Institutet, Stockholm, Sweden.,Stockholm Center for Bioelectronic Medicine, MedTechLabs, Karolinska University Hospital, Solna, Sweden
| | | | - Ihor Sahalianov
- Bioelectronics Materials and Devices Laboratory, Central European Institute of Technology, Brno University of Technology, Purkyňova 123, 61200 Brno, Czech Republic
| | - Vedran Đerek
- Department of Physics, Faculty of Science, University of Zagreb, Bijenička c. 32, 10000 Zagreb, Croatia
| | - Henrik Hult
- Stockholm Center for Bioelectronic Medicine, MedTechLabs, Karolinska University Hospital, Solna, Sweden.,Department of Mathematics, KTH, 11428 Stockholm, Sweden
| | - Peder S Olofsson
- Laboratory of Immunobiology, Center for Bioelectronic Medicine, Department of Medicine, Center for Molecular Medicine, Karolinska Institutet, Stockholm, Sweden.,Stockholm Center for Bioelectronic Medicine, MedTechLabs, Karolinska University Hospital, Solna, Sweden.,Institute of Bioelectronic Medicine, Feinstein Institutes for Medical Research, Manhasset, NY, United States of America
| | - Eric Daniel Głowacki
- Laboratory of Organic Electronics, Campus Norrköping, Linköping University, SE-60174 Norrköping, Sweden.,Bioelectronics Materials and Devices Laboratory, Central European Institute of Technology, Brno University of Technology, Purkyňova 123, 61200 Brno, Czech Republic
| |
Collapse
|
12
|
Bakhshaee Babaroud N, Palmar M, Velea AI, Coletti C, Weingärtner S, Vos F, Serdijn WA, Vollebregt S, Giagka V. Multilayer CVD graphene electrodes using a transfer-free process for the next generation of optically transparent and MRI-compatible neural interfaces. MICROSYSTEMS & NANOENGINEERING 2022; 8:107. [PMID: 36176270 PMCID: PMC9512798 DOI: 10.1038/s41378-022-00430-x] [Citation(s) in RCA: 11] [Impact Index Per Article: 3.7] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 03/07/2022] [Revised: 06/17/2022] [Accepted: 07/14/2022] [Indexed: 06/16/2023]
Abstract
Multimodal platforms combining electrical neural recording and stimulation, optogenetics, optical imaging, and magnetic resonance (MRI) imaging are emerging as a promising platform to enhance the depth of characterization in neuroscientific research. Electrically conductive, optically transparent, and MRI-compatible electrodes can optimally combine all modalities. Graphene as a suitable electrode candidate material can be grown via chemical vapor deposition (CVD) processes and sandwiched between transparent biocompatible polymers. However, due to the high graphene growth temperature (≥ 900 °C) and the presence of polymers, fabrication is commonly based on a manual transfer process of pre-grown graphene sheets, which causes reliability issues. In this paper, we present CVD-based multilayer graphene electrodes fabricated using a wafer-scale transfer-free process for use in optically transparent and MRI-compatible neural interfaces. Our fabricated electrodes feature very low impedances which are comparable to those of noble metal electrodes of the same size and geometry. They also exhibit the highest charge storage capacity (CSC) reported to date among all previously fabricated CVD graphene electrodes. Our graphene electrodes did not reveal any photo-induced artifact during 10-Hz light pulse illumination. Additionally, we show here, for the first time, that CVD graphene electrodes do not cause any image artifact in a 3T MRI scanner. These results demonstrate that multilayer graphene electrodes are excellent candidates for the next generation of neural interfaces and can substitute the standard conventional metal electrodes. Our fabricated graphene electrodes enable multimodal neural recording, electrical and optogenetic stimulation, while allowing for optical imaging, as well as, artifact-free MRI studies.
Collapse
Affiliation(s)
- Nasim Bakhshaee Babaroud
- Department of Microelectronics, Faculty of Electrical Engineering, Mathematics and Computer Science, Delft University of Technology, Mekelweg 4, Delft, 2628 CD The Netherlands
| | - Merlin Palmar
- Department of Microelectronics, Faculty of Electrical Engineering, Mathematics and Computer Science, Delft University of Technology, Mekelweg 4, Delft, 2628 CD The Netherlands
| | - Andrada Iulia Velea
- Department of Microelectronics, Faculty of Electrical Engineering, Mathematics and Computer Science, Delft University of Technology, Mekelweg 4, Delft, 2628 CD The Netherlands
- Technologies for Bioelectronics Group, Department of System Integration and Interconnection Technologies, Fraunhofer Institute for Reliability and Micro-integration IZM, Gustav-Meyer-Allee 25, Berlin, 13355 Germany
| | - Chiara Coletti
- Department of Imaging Physics, Faculty of Applied Science, Delft University of Technology, Lorentzweg 1, Delft, 2628 CJ The Netherlands
| | - Sebastian Weingärtner
- Department of Imaging Physics, Faculty of Applied Science, Delft University of Technology, Lorentzweg 1, Delft, 2628 CJ The Netherlands
| | - Frans Vos
- Department of Imaging Physics, Faculty of Applied Science, Delft University of Technology, Lorentzweg 1, Delft, 2628 CJ The Netherlands
| | - Wouter A. Serdijn
- Department of Microelectronics, Faculty of Electrical Engineering, Mathematics and Computer Science, Delft University of Technology, Mekelweg 4, Delft, 2628 CD The Netherlands
- Erasmus University Medical Center (Erasmus MC), dr. Molewaterplein 40, Rotterdam, 3015 GD The Netherlands
| | - Sten Vollebregt
- Department of Microelectronics, Faculty of Electrical Engineering, Mathematics and Computer Science, Delft University of Technology, Mekelweg 4, Delft, 2628 CD The Netherlands
| | - Vasiliki Giagka
- Department of Microelectronics, Faculty of Electrical Engineering, Mathematics and Computer Science, Delft University of Technology, Mekelweg 4, Delft, 2628 CD The Netherlands
- Technologies for Bioelectronics Group, Department of System Integration and Interconnection Technologies, Fraunhofer Institute for Reliability and Micro-integration IZM, Gustav-Meyer-Allee 25, Berlin, 13355 Germany
| |
Collapse
|
13
|
Valente V. Evolution of Biotelemetry in Medical Devices: From Radio Pills to mm-Scale Implants. IEEE TRANSACTIONS ON BIOMEDICAL CIRCUITS AND SYSTEMS 2022; 16:580-599. [PMID: 35834463 DOI: 10.1109/tbcas.2022.3190767] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/15/2023]
Abstract
The advent of semiconductor technology in the mid-20th century created unprecedented opportunities to develop a new generation of small-scale wireless medical sensing devices that can support remote monitoring of patients' vital signs. The first radio pills were developed as early as the 1950's using only a few transistors. These swallowable capsules could sense and wirelessly transmit vital parameters from inside the human body. Since then we have witnessed the rapid progress of medical devices driven by the evolution of semiconductor technology, from single-transistor oscillators to complex mixed-signal multi-channel and multi-modal systems. This paper retraces the evolution of biotelemetry devices from their very early inception to the smart miniaturized systems of modern days, focusing on semiconductor-enabled sensing methods and circuits developed over the last six decades. The paper also includes the author's perspective on current and future trends in the development of CMOS-based biotelemeters, focusing on concepts of implant modularity, miniaturization and hybrid energy harvesting solutions.
Collapse
|
14
|
Sevcencu C. Single-interface bioelectronic medicines - concept, clinical applications and preclinical data. J Neural Eng 2022; 19. [PMID: 35533654 DOI: 10.1088/1741-2552/ac6e08] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/04/2022] [Accepted: 05/08/2022] [Indexed: 11/12/2022]
Abstract
Presently, large groups of patients with various diseases are either intolerant, or irresponsive to drug therapies and also intractable by surgery. For several diseases, one option which is available for such patients is the implantable neurostimulation therapy. However, lacking closed-loop control and selective stimulation capabilities, the present neurostimulation therapies are not optimal and are therefore used as only "third" therapeutic options when a disease cannot be treated by drugs or surgery. Addressing those limitations, a next generation class of closed-loop controlled and selective neurostimulators generically named bioelectronic medicines seems within reach. A sub-class of such devices is meant to monitor and treat impaired functions by intercepting, analyzing and modulating neural signals involved in the regulation of such functions using just one neural interface for those purposes. The primary objective of this review is to provide a first broad perspective on this type of single-interface devices for bioelectronic therapies. For this purpose, the concept, clinical applications and preclinical studies for further developments with such devices are here analyzed in a narrative manner.
Collapse
Affiliation(s)
- Cristian Sevcencu
- National Institute for Research and Development of Isotopic and Molecular Technologies, 67-103 Donat Street, Cluj-Napoca, 400293, ROMANIA
| |
Collapse
|
15
|
Thin Film Encapsulation for LCP-Based Flexible Bioelectronic Implants: Comparison of Different Coating Materials Using Test Methodologies for Life-Time Estimation. MICROMACHINES 2022; 13:mi13040544. [PMID: 35457851 PMCID: PMC9028940 DOI: 10.3390/mi13040544] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 02/25/2022] [Revised: 03/22/2022] [Accepted: 03/28/2022] [Indexed: 02/01/2023]
Abstract
Liquid crystal polymer (LCP) has gained wide interest in the electronics industry largely due to its flexibility, stable insulation and dielectric properties and chip integration capabilities. Recently, LCP has also been investigated as a biocompatible substrate for the fabrication of multielectrode arrays. Realizing a fully implantable LCP-based bioelectronic device, however, still necessitates a low form factor packaging solution to protect the electronics in the body. In this work, we investigate two promising encapsulation coatings based on thin-film technology as the main packaging for LCP-based electronics. Specifically, a HfO2–based nanolaminate ceramic (TFE1) deposited via atomic layer deposition (ALD), and a hybrid Parylene C-ALD multilayer stack (TFE2), both with a silicone finish, were investigated and compared to a reference LCP coating. T-peel, water-vapour transmission rate (WVTR) and long-term electrochemical impedance spectrometry (EIS) tests were performed to evaluate adhesion, barrier properties and overall encapsulation performance of the coatings. Both TFE materials showed stable impedance characteristics while submerged in 60 °C saline, with TFE1-silicone lasting more than 16 months under a continuous 14V DC bias (experiment is ongoing). The results presented in this work show that WVTR is not the main factor in determining lifetime, but the adhesion of the coating to the substrate materials plays a key role in maintaining a stable interface and thus longer lifetimes.
Collapse
|
16
|
Dupan S, McNeill Z, Sarda E, Brunton E, Nazarpour K. How fast is too fast? Boundaries to the perception of electrical stimulation of peripheral nerves. IEEE Trans Neural Syst Rehabil Eng 2022; 30:782-788. [PMID: 35271444 DOI: 10.1109/tnsre.2022.3158067] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/06/2022]
Abstract
Transcutaneous electrical stimulation is a promising technique for providing prosthetic hand users with information about sensory events. However, questions remain over how to design the stimulation paradigms to provide users the best opportunity to discriminate these events. Here, we investigate if the refractory period influences how the amplitude of the applied stimulus is perceived. Twenty participants completed a two-alternative forced choice experiment. We delivered two stimuli spaced between 250 ms to 450 ms apart (inter-stimulus-interval, isi). The participants reported which stimulus they perceived as strongest. Each stimulus consisted of either a single or paired pulse delivered transcutaneously. The inter-pulse interval (ipi) for the paired pulse stimuli varied between 6 and 10 ms. We found paired pulses with an ipi of 6 ms were perceived stronger than a single pulse less often than paired pulses with an ipi of 8 ms (p = 0.001) or 10 ms (p < 0.0001). Additionally, we found when the isi was 250 ms, participants were less likely to identify the paired pulse as strongest, than when the isi was 350 or 450 ms. This study emphasizes the importance of basing stimulation paradigms on the underlying neural physiology. The results indicate there is an upper limit to the commonly accepted notion that higher stimulation frequencies lead to stronger perception. If frequency is to be used to encode sensory events, then the results suggest stimulus paradigms should be designed using frequencies below 125 Hz.
Collapse
|
17
|
Rowan CC, Graudejus O, Otchy TM. A Microclip Peripheral Nerve Interface (μcPNI) for Bioelectronic Interfacing with Small Nerves. ADVANCED SCIENCE (WEINHEIM, BADEN-WURTTEMBERG, GERMANY) 2022; 9:e2102945. [PMID: 34837353 PMCID: PMC8787429 DOI: 10.1002/advs.202102945] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 07/12/2021] [Revised: 08/31/2021] [Indexed: 06/13/2023]
Abstract
Peripheral nerves carry sensory (afferent) and motor (efferent) signals between the central nervous system and other parts of the body. The peripheral nervous system (PNS) is therefore rich in targets for therapeutic neuromodulation, bioelectronic medicine, and neuroprosthetics. Peripheral nerve interfaces (PNIs) generally suffer from a tradeoff between selectivity and invasiveness. This work describes the fabrication, evaluation, and chronic implantation in zebra finches of a novel PNI that breaks this tradeoff by interfacing with small nerves. This PNI integrates a soft, stretchable microelectrode array with a 2-photon 3D printed microclip (μcPNI). The advantages of this μcPNI compared to other designs are: a) increased spatial resolution due to bi-layer wiring of the electrode leads, b) reduced mismatch in biomechanical properties with the nerve, c) reduced disturbance to the host tissue due to the small size, d) elimination of sutures or adhesives, e) high circumferential contact with small nerves, f) functionality under considerable strain, and g) graded neuromodulation in a low-threshold stimulation regime. Results demonstrate that the μcPNIs are electromechanically robust, and are capable of reliably recording and stimulating neural activity in vivo in small nerves. The μcPNI may also inform the development of new optical, thermal, ultrasonic, or chemical PNIs as well.
Collapse
Affiliation(s)
| | - Oliver Graudejus
- BMSEED LLCPhoenixAZ85034USA
- School of Molecular SciencesArizona State UniversityTempeAZ85281USA
| | - Timothy M. Otchy
- Department of BiologyBoston UniversityBostonMA02215USA
- Neurophotonics CenterBoston UniversityBostonMA02215USA
- Center for Systems NeuroscienceBoston UniversityBostonMA02215USA
| |
Collapse
|
18
|
Carnevale L, Perrotta M, Lembo G. A Focused Review of Neural Recording and Stimulation Techniques With Immune-Modulatory Targets. Front Immunol 2021; 12:689344. [PMID: 34646261 PMCID: PMC8502970 DOI: 10.3389/fimmu.2021.689344] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/31/2021] [Accepted: 09/09/2021] [Indexed: 12/12/2022] Open
Abstract
The complex interactions established between the nervous and immune systems have been investigated for a long time. With the advent of small and portable devices to record and stimulate nerve activity, researchers from many fields began to be interested in how nervous activity can elicit immune responses and whether this activity can be manipulated to trigger specific immune responses. Pioneering works demonstrated the existence of a cholinergic inflammatory reflex, capable of controlling the systemic inflammatory response through a vagus nerve-mediated modulation of the spleen. This work inspired many different areas of technological and conceptual advancement, which are here reviewed to provide a concise reference for the main works expanding the knowledge on vagus nerve immune-modulatory capabilities. In these works the enabling technologies of peripheral nervous activity recordings were implemented and embody the current efforts aimed at controlling neural activity with modulating functions in immune response, both in experimental and clinical contexts.
Collapse
Affiliation(s)
- Lorenzo Carnevale
- Research Unit of Neuro and Cardiovascular Pathophysiology, IRCCS Neuromed, Department of Angiocardioneurology and Translational Medicine, Pozzilli (IS), Italy
| | - Marialuisa Perrotta
- Department of Molecular Medicine, "Sapienza" University of Rome, Rome, Italy
| | - Giuseppe Lembo
- Research Unit of Neuro and Cardiovascular Pathophysiology, IRCCS Neuromed, Department of Angiocardioneurology and Translational Medicine, Pozzilli (IS), Italy.,Department of Molecular Medicine, "Sapienza" University of Rome, Rome, Italy
| |
Collapse
|
19
|
Veith A, Li X, Modi H, Abbaspour A, Luan L, Xie C, Baker AB. Optimized design of a hyperflexible sieve electrode to enhance neurovascular regeneration for a peripheral neural interface. Biomaterials 2021; 275:120924. [PMID: 34147716 PMCID: PMC9939235 DOI: 10.1016/j.biomaterials.2021.120924] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/02/2020] [Revised: 05/13/2021] [Accepted: 05/23/2021] [Indexed: 11/24/2022]
Abstract
One in 190 Americans is currently living with the loss of a limb resulted from injury, amputation, or neurodegenerative disease. Advanced neuroprosthetic devices combine peripheral neural interfaces with sophisticated prosthetics and hold great potential for the rehabilitation of impaired motor and sensory functions. While robotic prosthetics have advanced very rapidly, peripheral neural interfaces have long been limited by the capability of interfacing with the peripheral nervous system. In this work, we developed a hyperflexible regenerative sieve electrode to serve as a peripheral neural interface. We examined tissue neurovascular integration through this novel device. We demonstrated that we could enhance the neurovascular invasion through the device with directional growth factor delivery. Furthermore, we demonstrated that we could reduce the tissue reaction to the device often seen in peripheral neural interfaces. Finally, we show that we can create a stable tissue device interface in a long-term implantation that does not impede the normal regenerative processes of the nerve. Our study developed an optimal platform for the continued development of hyperflexible sieve electrode peripheral neural interfaces.
Collapse
Affiliation(s)
- Austin Veith
- The University of Texas at Austin, Department of Biomedical Engineering, Austin, TX, USA
| | - Xue Li
- Rice University, Department of Electrical and Computer Engineering, Houston, TX, USA
| | - Hailey Modi
- The University of Texas at Austin, Department of Biomedical Engineering, Austin, TX, USA
| | - Ali Abbaspour
- The University of Texas at Austin, Department of Biomedical Engineering, Austin, TX, USA
| | - Lan Luan
- Rice University, Department of Electrical and Computer Engineering, Houston, TX, USA
| | - Chong Xie
- Rice University, Department of Electrical and Computer Engineering, Houston, TX, USA
| | - Aaron B Baker
- The University of Texas at Austin, Department of Biomedical Engineering, Austin, TX, USA; Institute for Cellular and Molecular Biology, The University of Texas at Austin, Austin, TX, USA; Institute for Computational Engineering and Sciences, The University of Texas at Austin, Austin, TX, USA; Institute for Biomaterials, Drug Delivery and Regenerative Medicine, The University of Texas at Austin, Austin, TX, USA.
| |
Collapse
|
20
|
Kundu A, Fahmy A, Madler R, Otto K, Patrick E, Principe J, Maghari N, Bashirullah R. A multi-channel peripheral nerve stimulator with integrate-and-fire encoding. J Med Eng Technol 2021; 45:187-196. [PMID: 33729074 DOI: 10.1080/03091902.2021.1891311] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/11/2023]
Abstract
Activation of peripheral nervous system (PNS) fibres to produce variable tactile and proprioceptive sensations in advanced bidirectional prosthetic limbs relies on neural stimulators with high spatial selectivity, dynamic range and resolution. A multi-channel application-specific integrated circuit (ASIC) is developed for PNS fibre activation using a wide dynamic range (10 nA-5 mA), high-resolution (30 nA step, 100 ns pulse accuracy) current stimulator, dissipating 0.73-2.75 mW at 3 V. The ASIC also enables encoding of external pressure signals via an integrate-and-fire methodology. Electrophysiological data of compound nerve action potentials were recorded for a range of stimulus amplitudes and pulse widths. This data was used to benchmark the performance of the ASIC with a known neural stimulator.
Collapse
Affiliation(s)
- Aritra Kundu
- Department of Neurology, Dell Medical School, The University of Texas at Austin, Austin, TX, USA
| | - Ahmed Fahmy
- Department of Electrical and Computer Engineering, University of Florida, Gainesville, FL, USA
| | - Ryan Madler
- Department of Electrical and Computer Engineering, University of Florida, Gainesville, FL, USA
| | - Kevin Otto
- Department of Biomedical Engineering, University of Florida, Gainesville, FL, USA
| | - Erin Patrick
- Department of Electrical and Computer Engineering, University of Florida, Gainesville, FL, USA
| | - Jose Principe
- Department of Electrical and Computer Engineering, University of Florida, Gainesville, FL, USA
| | - Nima Maghari
- Department of Electrical and Computer Engineering, University of Florida, Gainesville, FL, USA
| | | |
Collapse
|
21
|
Mobini S, Kuliasha CA, Siders ZA, Bohmann NA, Jamal SM, Judy JW, Schmidt CE, Brennan AB. Microtopographical patterns promote different responses in fibroblasts and Schwann cells: A possible feature for neural implants. J Biomed Mater Res A 2021; 109:64-76. [PMID: 32419308 PMCID: PMC8059778 DOI: 10.1002/jbm.a.37007] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/26/2019] [Revised: 02/28/2020] [Accepted: 04/19/2020] [Indexed: 02/04/2023]
Abstract
The chronic reliability of bioelectronic neural interfaces has been challenged by foreign body reactions (FBRs) resulting in fibrotic encapsulation and poor integration with neural tissue. Engineered microtopographies could alleviate these challenges by manipulating cellular responses to the implanted device. Parallel microchannels have been shown to modulate neuronal cell alignment and axonal growth, and Sharklet™ microtopographies of targeted feature sizes can modulate bio-adhesion of an array of bacteria, marine organisms, and epithelial cells due to their unique geometry. We hypothesized that a Sharklet™ micropattern could be identified that inhibited fibroblasts partially responsible for FBR while promoting Schwann cell proliferation and alignment. in vitro cell assays were used to screen the effect of Sharklet™ and channel micropatterns of varying dimensions from 2 to 20 μm on fibroblast and Schwann cell metrics (e.g., morphology/alignment, nuclei count, metabolic activity), and a hierarchical analysis of variance was used to compare treatments. In general, Schwann cells were found to be more metabolically active and aligned than fibroblasts when compared between the same pattern. 20 μm wide channels spaced 2 μm apart were found to promote Schwann cell attachment and alignment while simultaneously inhibiting fibroblasts and warrant further in vivo study on neural interface devices. No statistically significant trends between cellular responses and geometrical parameters were identified because mammalian cells can change their morphology dependent on their environment in a manner dissimilar to bacteria. Our results showed although surface patterning is a strong physical tool for modulating cell behavior, responses to micropatterns are highly dependent on the cell type.
Collapse
Affiliation(s)
- Sahba Mobini
- Crayton Pruitt Family Department of Biomedical Engineering University of Florida, USA
- Instituto de Micro y Nanotecnología, IMN-CNM, CSIC (CEI UAM+CSIC), Madrid, Spain
- Departamento de Biología Molecular and Centro de Biología Molecular “Severo Ochoa” (UAM-CSIC), Universidad Autónoma de Madrid, Spain
| | - Cary A. Kuliasha
- Nanoscience Institute for Medical and Engineering Technology, University of Florida, USA
| | - Zachary A. Siders
- Fisheries and Aquatic Sciences Program, School of Forest Resources and Conservation, University of Florida, USA
| | - Nicole A. Bohmann
- Crayton Pruitt Family Department of Biomedical Engineering University of Florida, USA
| | - Syed-Mustafa Jamal
- Crayton Pruitt Family Department of Biomedical Engineering University of Florida, USA
| | - Jack W. Judy
- Nanoscience Institute for Medical and Engineering Technology, University of Florida, USA
| | - Christine E. Schmidt
- Crayton Pruitt Family Department of Biomedical Engineering University of Florida, USA
| | - Anthony B. Brennan
- Crayton Pruitt Family Department of Biomedical Engineering University of Florida, USA
- Materials Science and Engineering Department, University of Florida, USA
| |
Collapse
|
22
|
Akgun OC, Nanbakhsh K, Giagka V, Serdijn WA. A Chip Integrity Monitor for Evaluating Moisture/Ion Ingress in mm-Sized Single-Chip Implants. IEEE TRANSACTIONS ON BIOMEDICAL CIRCUITS AND SYSTEMS 2020; 14:658-670. [PMID: 32746351 DOI: 10.1109/tbcas.2020.3007484] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/11/2023]
Abstract
For mm-sized implants incorporating silicon integrated circuits, ensuring lifetime operation of the chip within the corrosive environment of the body still remains a critical challenge. For the chip's packaging, various polymeric and thin ceramic coatings have been reported, demonstrating high biocompatibility and barrier properties. Yet, for the evaluation of the packaging and lifetime prediction, the conventional helium leak test method can no longer be applied due to the mm-size of such implants. Alternatively, accelerated soak studies are typically used instead. For such studies, early detection of moisture/ion ingress using an in-situ platform may result in a better prediction of lifetime functionality. In this work, we have developed such a platform on a CMOS chip. Ingress of moisture/ions would result in changes in the resistance of the interlayer dielectrics (ILD) used within the chip and can be tracked using the proposed system, which consists of a sensing array and an on-chip measurement engine. The measurement system uses a novel charge/discharge based time-mode resistance sensor that can be implemented using simple yet highly robust circuitry. The sensor array is implemented together with the measurement engine in a standard 0.18 μm 6-metal CMOS process. The platform was validated through a series of dry and wet measurements. The system can measure the ILD resistance with values of up to 0.504 peta-ohms, with controllable measurement steps that can be as low as 0.8 M Ω. The system works with a supply voltage of 1.8 V, and consumes 4.78 mA. Wet measurements in saline demonstrated the sensitivity of the platform in detecting moisture/ion ingress. Such a platform could be used both in accelerated soak studies and during the implant's life-time for monitoring the integrity of the chip's packaging.
Collapse
|
23
|
Babaroud NB, Dekker R, Serdijn W, Giagka V. PDMS-Parylene Adhesion Improvement via Ceramic Interlayers to Strengthen the Encapsulation of Active Neural Implants. ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY. IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY. ANNUAL INTERNATIONAL CONFERENCE 2020; 2020:3399-3402. [PMID: 33018733 DOI: 10.1109/embc44109.2020.9175646] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/11/2023]
Abstract
Parylene-C has been used as a substrate and encapsulation material for many implantable medical devices. However, to ensure the flexibility required in some applications, minimize tissue reaction, and protect parylene from degradation in vivo an additional outmost layer of polydimethylsiloxane (PDMS) is desired. In such a scenario, the adhesion of PDMS to parylene is of critical importance to prevent early failure caused by delamination in the harsh environment of the human body. Towards this goal, we propose a method based on creating chemical covalent bonds using intermediate ceramic layers as adhesion promoters between PDMS and parylene.To evaluate our concept, we prepared three different sets of samples with PDMS on parylene without and with oxygen plasma treatment (the most commonly employed method to increase adhesion), and samples with our proposed ceramic intermediate layers of silicon carbide (SiC) and silicon dioxide (SiO2). The samples were soaked in phosphate-buffered saline (PBS) solution at room temperature and were inspected under an optical microscope. To investigate the adhesion property, cross-cut tape tests and peel tests were performed. The results showed a significant improvement of the adhesion and in-soak long-term performance of our proposed encapsulation stack compared with PDMS on parylene and PDMS on plasma-treated parylene. We aim to use the proposed solution to package bare silicon chips on active implants.
Collapse
|
24
|
Nanbakhsh K, Ritasalo R, Serdijn WA, Giagka V. Towards CMOS Bulk Sensing for In-Situ Evaluation of ALD Coatings for Millimeter Sized Implants. ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY. IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY. ANNUAL INTERNATIONAL CONFERENCE 2020; 2020:3436-3439. [PMID: 33018742 DOI: 10.1109/embc44109.2020.9176103] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/11/2023]
Abstract
To meet the dimensional requirements for bioelectronic medicine, new packaging solutions are needed that could enable small, light-weight and flexible implants. For protecting the implantable electronics against biofluids, recently various atomic layer deposited (ALD) coatings have been proposed with high barrier properties. Before implantation, however, the protective coating should be evaluated for any defects which could otherwise lead to leakage and device failure. In these cases, the conventional helium leak test method can no longer be used due to the millimeter size of the implant. Therefore, an in-situ sensing platform is needed that could evaluate the coating and justify the implantation of the final device. In this work, we explore the possibility of using the CMOS bulk for such a platform. Towards this aim, as a proof of concept, test chips were made in a standard 6-metal 0.18 µm CMOS process and for the connection to the bulk, a p+ diffusion was used. A group of samples was then coated with an ALD multilayer. For coating evaluation, off-chip DC current leakage and impedance measurements were carried out in saline between the CMOS bulk and a platinum reference electrode. Results were compared between non-coated and coated chips that clearly demonstrated the potential of using the bulk as a sensing platform for coating evaluations. This novel approach could pave the way towards an all integrated in-situ hermeticity test, currently missing in mm-size implants.
Collapse
|
25
|
Nanbakhsh K, Kluba M, Pahl B, Bourgeois F, Dekker R, Serdijn W, Giagka V. Effect of Signals on the Encapsulation Performance of Parylene Coated Platinum Tracks for Active Medical Implants. ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY. IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY. ANNUAL INTERNATIONAL CONFERENCE 2020; 2019:3840-3844. [PMID: 31946711 DOI: 10.1109/embc.2019.8857702] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/10/2022]
Abstract
Platinum is widely used as the electrode material for implantable devices. Owing to its high biostability and corrosion resistivity, platinum could also be used as the main metallization for tracks in active implants. Towards this goal, in this work we investigate the stability of parylene-coated Pt tracks using passive and active tests. The test samples in this study are Pt-on-SiO2 interdigitated comb structures. During testing all samples were immersed in saline for 150 days; for passive testing, the samples were left unbiased, whilst for active testing, samples were exposed to two different stress signals: a 5 V DC and a 5 Vp 500 pulses per second biphasic signal. All samples were monitored over time using impedance spectroscopy combined with optical inspection. After the first two weeks of immersion, delamination spots were observed on the Pt tracks for both passive and actively tested samples. Despite the delamination spots, the unbiased samples maintained high impedances until the end of the study. For the actively stressed samples, two different failure mechanisms were observed which were signal related. DC stressed samples showed severe parylene cracking mainly due to the electrolysis of the condensed water. Biphasically stressed samples showed gradual Pt dissolution and migration. These results contribute to a better understanding of the failure mechanisms of Pt tracks in active implants and suggest that new testing paradigms may be necessary to fully assess the long-term reliability of these devices.
Collapse
|
26
|
Pavlov VA, Chavan SS, Tracey KJ. Bioelectronic Medicine: From Preclinical Studies on the Inflammatory Reflex to New Approaches in Disease Diagnosis and Treatment. Cold Spring Harb Perspect Med 2020; 10:a034140. [PMID: 31138538 PMCID: PMC7050582 DOI: 10.1101/cshperspect.a034140] [Citation(s) in RCA: 48] [Impact Index Per Article: 9.6] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/11/2022]
Abstract
Bioelectronic medicine is an evolving field in which new insights into the regulatory role of the nervous system and new developments in bioelectronic technology result in novel approaches in disease diagnosis and treatment. Studies on the immunoregulatory function of the vagus nerve and the inflammatory reflex have a specific place in bioelectronic medicine. These studies recently led to clinical trials with bioelectronic vagus nerve stimulation in inflammatory diseases and other conditions. Here, we outline key findings from this preclinical and clinical research. We also point to other aspects and pillars of interdisciplinary research and technological developments in bioelectronic medicine.
Collapse
Affiliation(s)
- Valentin A Pavlov
- Center for Biomedical Science and Bioelectronic Medicine, The Feinstein Institute for Medical Research, Northwell Health, Manhasset, New York 11030
- Donald and Barbara Zucker School of Medicine at Hofstra/Northwell, Hempstead, New York 11550
| | - Sangeeta S Chavan
- Center for Biomedical Science and Bioelectronic Medicine, The Feinstein Institute for Medical Research, Northwell Health, Manhasset, New York 11030
- Donald and Barbara Zucker School of Medicine at Hofstra/Northwell, Hempstead, New York 11550
| | - Kevin J Tracey
- Center for Biomedical Science and Bioelectronic Medicine, The Feinstein Institute for Medical Research, Northwell Health, Manhasset, New York 11030
- Donald and Barbara Zucker School of Medicine at Hofstra/Northwell, Hempstead, New York 11550
| |
Collapse
|
27
|
Liu Y, Urso A, Martins da Ponte R, Costa T, Valente V, Giagka V, Serdijn WA, Constandinou TG, Denison T. Bidirectional Bioelectronic Interfaces: System Design and Circuit Implications. ACTA ACUST UNITED AC 2020. [DOI: 10.1109/mssc.2020.2987506] [Citation(s) in RCA: 21] [Impact Index Per Article: 4.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/06/2022]
|
28
|
A review for the peripheral nerve interface designer. J Neurosci Methods 2019; 332:108523. [PMID: 31743684 DOI: 10.1016/j.jneumeth.2019.108523] [Citation(s) in RCA: 71] [Impact Index Per Article: 11.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/07/2019] [Revised: 11/14/2019] [Accepted: 11/15/2019] [Indexed: 12/11/2022]
Abstract
Informational density and relative accessibility of the peripheral nervous system make it an attractive site for therapeutic intervention. Electrode-based electrophysiological interfaces with peripheral nerves have been under development since the 1960s and, for several applications, have seen widespread clinical implementation. However, many applications require a combination of neural target resolution and stability which has thus far eluded existing peripheral nerve interfaces (PNIs). With the goal of aiding PNI designers in development of devices that meet the demands of next-generation applications, this review seeks to collect and present practical considerations and best practices which emerge from the literature, including both lessons learned during early PNI development and recent ideas. Fundamental and practical principles guiding PNI design are reviewed, followed by an updated and critical account of existing PNI designs and strategies. Finally, a brief survey of in vitro and in vivo PNI characterization methods is presented.
Collapse
|
29
|
Urso A, Giagka V, van Dongen M, Serdijn WA. An Ultra High-Frequency 8-Channel Neurostimulator Circuit With [Formula: see text] Peak Power Efficiency. IEEE TRANSACTIONS ON BIOMEDICAL CIRCUITS AND SYSTEMS 2019; 13:882-892. [PMID: 31170080 DOI: 10.1109/tbcas.2019.2920294] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/09/2023]
Abstract
In order to recruit neurons in excitable tissue, constant current neural stimulators are commonly used. Recently, ultra high-frequency (UHF) stimulation has been proposed and proven to have the same efficacy as constant-current stimulation. UHF stimulation uses a fundamentally different way of activating the tissue: each stimulation phase is made of a burst of current pulses with adjustable amplitude injected into the tissue at a high (e.g., [Formula: see text]) frequency. This paper presents the design, integrated circuit (IC) implementation, and measurement results of a power efficient multichannel UHF neural stimulator. The core of the neurostimulator is based on our previously proposed architecture of an inductor-based buck-boost dc-dc converter without the external output capacitor. The ultimate goal of this work is to increase the power efficiency of the UHF stimulator for multiple-channel operation, while keeping the number of external components minimal. To this end, a number of novel approaches were employed in the integrated circuit design domain. More specifically, a novel zero-current detection scheme is proposed. It allows to remove the freewheel diode typically used in dc-dc converters to prevent current to flow back from the load to the inductor. Furthermore, a gate-driver circuit is implemented which allows the use of thin gate-oxide transistors as high-voltage switches. By doing so, and exploiting the fundamental working principle of the proposed current-controlled UHF stimulator, the need for a high-voltage supply is eliminated and the stimulator is powered up from a [Formula: see text] input voltage. Both the current detection technique and the gate driving circuit of the current implementation allow to boost the power efficiency up to [Formula: see text] when compared to previous UHF stimulator works. A peak power efficiency of [Formula: see text] is achieved, while 8 independent channels with 16 fully configurable electrodes are used. The circuit is implemented in a [Formula: see text] HV process, and the total chip area is [Formula: see text].
Collapse
|
30
|
Pavlov VA, Tracey KJ. Bioelectronic medicine: updates, challenges and paths forward. Bioelectron Med 2019; 5:1. [PMID: 32232092 PMCID: PMC7098260 DOI: 10.1186/s42234-019-0018-y] [Citation(s) in RCA: 36] [Impact Index Per Article: 6.0] [Reference Citation Analysis] [Track Full Text] [Download PDF] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/11/2019] [Accepted: 01/11/2019] [Indexed: 12/30/2022] Open
Affiliation(s)
- Valentin A Pavlov
- 1Center for Biomedical Science and Center for Bioelectronic Medicine, The Feinstein Institute for Medical Research, Northwell Health System, Manhasset, NY USA
- Donald and Barbara Zucker School of Medicine at Hofstra/Northwell, Hempstead, NY USA
| | - Kevin J Tracey
- 1Center for Biomedical Science and Center for Bioelectronic Medicine, The Feinstein Institute for Medical Research, Northwell Health System, Manhasset, NY USA
- Donald and Barbara Zucker School of Medicine at Hofstra/Northwell, Hempstead, NY USA
| |
Collapse
|