1
|
Maïmoun L, Gelis A, Serrand C, Mura T, Brabant S, Garnero P, Mariano-Goulart D, Fattal C. Whole-body vibration may not affect bone mineral density and bone turnover in persons with chronic spinal cord injury: A preliminary study. J Spinal Cord Med 2025; 48:259-271. [PMID: 37930641 PMCID: PMC11864013 DOI: 10.1080/10790268.2023.2268893] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/07/2023] Open
Abstract
CONTEXT Spinal-cord injury (SCI) induces bone loss and dramatically increases the risk of fracture. OBJECTIVES Determine the effects of whole-body vibration (WBV) on areal bone mineral density (aBMD), whole body composition and bone biological parameters in individuals with chronic-state SCI. DESIGN Randomized study. SETTING Centre Neurologique PROPARA. PARTICIPANTS Fourteen subjects were randomly assigned to a WBV or a control group. INTERVENTIONS WBV (20-45 min, 30-45 Hz, 0.5 g) was performed in verticalized persons twice weekly for 6 months. OUTCOME MEASURES aBMD was measured by DXA at baseline and 6 months and bone biological parameters at baseline, 1, 3 and 6 months. RESULTS No significant aBMD change was found in either the WBV or control group after 6 months of follow-up. Similarly, periostin, sclerostin and bone turnover markers remained relatively stable throughout follow-up and no difference in variation was observed within-group and between groups. Except for whole-body fat mass, which showed a significant decrease in the WBV group compared to controls, no difference in changes was observed, whatever the localization for fat and lean body mass. CONCLUSIONS During the chronic phase, aBMD and bone remodeling reach a new steady state. However, the DXA technique and the bone markers, including sclerostin and periostin, both of which reflect bone cell activity influenced by mechanical strain, showed that the bone tissue of individuals with SCI was insensitive to 6 months of WBV training at the study dose. Nevertheless, results of this preliminary study that was underpowered need to be confirmed and other modalities of WBV may be more effective in improving aBMD of this population. TRIALS REGISTRATION N°IDRCB:2011-A00224-37.
Collapse
Affiliation(s)
- Laurent Maïmoun
- Département de Médecine Nucléaire, Hôpital Lapeyronie, CHU Montpellier, Montpellier, France
- PhyMedExp, INSERM, CNRS, Université de Montpellier, Montpellier, France
| | | | - Chris Serrand
- Unité de Recherche Clinique et Epidémiologie, Hôpital La Colombière, CHU Montpellier, Montpellier, France
| | - Thibault Mura
- BESPIM -Hôpital Caremeau, CHRU de Nîmes, Nîmes, France
| | - Severine Brabant
- Laboratoire des Explorations Fonctionnelles, Hôpital Necker, Paris, France
| | | | - Denis Mariano-Goulart
- Département de Médecine Nucléaire, Hôpital Lapeyronie, CHU Montpellier, Montpellier, France
- PhyMedExp, INSERM, CNRS, Université de Montpellier, Montpellier, France
| | | |
Collapse
|
2
|
Hoffman DB, Schifino AG, Cooley MA, Zhong RX, Heo J, Morris CM, Campbell MJ, Warren GL, Greising SM, Call JA. Low intensity, high frequency vibration training to improve musculoskeletal function in a mouse model of volumetric muscle loss. J Orthop Res 2025; 43:622-631. [PMID: 39610268 PMCID: PMC11806655 DOI: 10.1002/jor.26023] [Citation(s) in RCA: 1] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 08/15/2024] [Revised: 10/04/2024] [Accepted: 10/31/2024] [Indexed: 11/30/2024]
Abstract
This study's objective was to investigate the extent to which two different levels of low-intensity vibration training (0.6 g or 1.0 g) affected musculoskeletal structure and function after a volumetric muscle loss (VML) injury in male C57BL/6J mice. All mice received a unilateral VML injury to the posterior plantar flexors. Mice were randomized into a control group (no vibration; VML-noTX), or one of two experimental groups. The two experimental groups received vibration training for 15-min/day, 5-days/week for 8 weeks at either 0.6 g (VML-0.6 g) or 1.0 g (VML-1.0 g) beginning 3-days after induction of VML. Muscles were analyzed for contractile and metabolic adaptations. Tibial bone mechanical properties and geometric structure were assessed by a three-point bending test and microcomputed tomography (µCT). Body mass-normalized peak isometric-torque was 18% less in VML-0.6 g mice compared with VML-noTx mice (p = 0.030). There were no statistically significant differences of vibration intervention on contractile power or muscle oxygen consumption (p ≥ 0.191). Bone ultimate load, but not stiffness, was ~16% greater in tibias of VML-1.0 g mice compared with those from VML-noTx mice (p = 0.048). Cortical bone volume was ~12% greater in tibias of both vibration groups compared with VML-noTx mice (p = 0.003). Importantly, cross-section moment of inertia, the primary determinant of bone ultimate load, was 44% larger in tibias of VML-0.6 g mice compared with VML-noTx mice (p = 0.006). These changes indicate that following VML, bones are more responsive to the selected vibration training parameters than muscle. Vibration training represents a possible adjuvant intervention to address bone deficits following VML.
Collapse
Affiliation(s)
| | | | - Marion A. Cooley
- Department of Oral Biology and Diagnostic Sciences, Dental College of GeorgiaAugust UniversityAugustaGeorgiaUSA
| | - Roger X. Zhong
- Department of Neuroscience and Regenerative MedicineAugusta UniversityAugustaGeorgiaUSA
| | - Junwon Heo
- Department of Physiology & PharmacologyUniversity of GeorgiaAthensGeorgiaUSA
| | - Courtney M. Morris
- Department of Physiology & PharmacologyUniversity of GeorgiaAthensGeorgiaUSA
| | - Matthew J. Campbell
- Department of Physiology & PharmacologyUniversity of GeorgiaAthensGeorgiaUSA
| | - Gordon L. Warren
- Department of Physical TherapyGeorgia State UniversityAtlantaGeorgiaUSA
| | | | - Jarrod A. Call
- Department of Physiology & PharmacologyUniversity of GeorgiaAthensGeorgiaUSA
- Regenerative Bioscience CenterUniversity of GeorgiaAthensGeorgiaUSA
| |
Collapse
|
3
|
Regner AM, DeLeon M, Gibbons KD, Howard S, Nesbitt DQ, Darghiasi SF, Zavala AG, Lujan TJ, Fitzpatrick CK, Farach-Carson MC, Wu D, Uzer G. Increased deformations are dispensable for encapsulated cell mechanoresponse in engineered bone analogs mimicking aging bone marrow. MECHANOBIOLOGY IN MEDICINE 2025; 3:100097. [PMID: 40134991 PMCID: PMC11936507 DOI: 10.1016/j.mbm.2024.100097] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Indexed: 03/27/2025]
Abstract
Aged individuals and astronauts experience bone loss despite rigorous physical activity. Bone mechanoresponse is in-part regulated by mesenchymal stem cells (MSCs) that respond to mechanical stimuli. Direct delivery of low intensity vibration (LIV) recovers MSC proliferation in senescence and simulated microgravity models, indicating that age-related reductions in mechanical signal delivery within bone marrow may contribute to declining bone mechanoresponse. To answer this question, we developed a 3D bone marrow analog that controls trabecular geometry, marrow mechanics and external stimuli. Validated finite element (FE) models were developed to quantify strain environment within hydrogels during LIV. Bone marrow analogs with gyroid-based trabeculae of scaffold volume fractions (SV/TV) corresponding to adult (25 %) and aged (13 %) mice were printed using polylactic acid (PLA). MSCs encapsulated in migration-permissive hydrogels within printed trabeculae showed robust cell populations on both PLA surface and hydrogel within a week. Following 14 days of LIV treatment (1 g, 100 Hz, 1 h/day), cell proliferation, type-I collagen (Collagen-I) and filamentous actin (F-actin) were quantified for the cells in the hydrogel fraction. While LIV increased all measured outcomes, FE models predicted higher von Mises strains for the 13 % SV/TV groups (0.2 %) when compared to the 25 % SV/TV group (0.1 %). While LIV increased collagen-I volume 34 % more in 13 % SV/TV groups when compared to 25 % SV/TV groups, collagen-I and F-actin measures remained lower in the 13 % SV/TV groups when compared to 25 % SV/TV counterparts, indicating that both LIV-induced strains and scaffold volume fraction (i.e. available scaffold surface) affect cell behavior in the hydrogel phase. Overall, bone marrow analogs offer a robust and repeatable platform to study bone mechanobiology.
Collapse
Affiliation(s)
- Alexander M. Regner
- Mechanical and Biomedical Engineering Department, Boise State University, USA
| | - Maximilien DeLeon
- Department of Diagnostic and Biomedical Sciences, UTHealth Houston School of Dentistry, USA
- Department of Bioengineering, Rice University, USA
| | - Kalin D. Gibbons
- Mechanical and Biomedical Engineering Department, Boise State University, USA
| | - Sean Howard
- Mechanical and Biomedical Engineering Department, Boise State University, USA
| | | | | | - Anamaria G. Zavala
- Mechanical and Biomedical Engineering Department, Boise State University, USA
| | - Trevor J. Lujan
- Mechanical and Biomedical Engineering Department, Boise State University, USA
| | | | - Mary C. Farach-Carson
- Department of Diagnostic and Biomedical Sciences, UTHealth Houston School of Dentistry, USA
- Department of Bioengineering, Rice University, USA
- Department of Biosciences, Rice University, USA
| | - Danielle Wu
- Department of Diagnostic and Biomedical Sciences, UTHealth Houston School of Dentistry, USA
- Department of Bioengineering, Rice University, USA
| | - Gunes Uzer
- Mechanical and Biomedical Engineering Department, Boise State University, USA
| |
Collapse
|
4
|
Pirri C. Exploring the Revolutionary Impact of YAP Pathways on Physical and Rehabilitation Medicine. Biomolecules 2025; 15:96. [PMID: 39858490 PMCID: PMC11764055 DOI: 10.3390/biom15010096] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/16/2024] [Revised: 12/20/2024] [Accepted: 01/07/2025] [Indexed: 01/27/2025] Open
Abstract
Cellular behavior is strongly influenced by mechanical signals in the surrounding microenvironment, along with external factors such as temperature fluctuations, changes in blood flow, and muscle activity, etc. These factors are key in shaping cellular states and can contribute to the development of various diseases. In the realm of rehabilitation physical therapies, therapeutic exercise and manual treatments, etc., are frequently employed, not just for pain relief but also to support recovery from diverse health conditions. However, the detailed molecular pathways through which these therapies interact with tissues and influence gene expression are not yet fully understood. The identification of YAP has been instrumental in closing this knowledge gap. YAP is known for its capacity to perceive and translate mechanical signals into specific transcriptional programs within cells. This insight has opened up new perspectives on how physical and rehabilitation medicine may exert its beneficial effects. The review investigates the involvement of the Hippo/YAP signaling pathway in various diseases and considers how different rehabilitation techniques leverage this pathway to aid in healing. Additionally, it examines the therapeutic potential of modulating the Hippo/YAP pathway within the context of rehabilitation, while also addressing the challenges and controversies that surround its use in physical and rehabilitation medicine.
Collapse
Affiliation(s)
- Carmelo Pirri
- Department of Neuroscience, Institute of Human Anatomy, University of Padova, 35121 Padova, Italy
| |
Collapse
|
5
|
Valkani D, Evans LAE, Pitsillides AA. In Vivo Models of Mechanical Loading. Methods Mol Biol 2025; 2885:359-381. [PMID: 40448771 DOI: 10.1007/978-1-0716-4306-8_19] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 06/02/2025]
Abstract
The skeleton fulfills its mechanical functions through structural organization and material properties of individual bones. It is stated that both cortical and trabecular morphology and mass can be (re)modeled in response to changes in mechanical strains engendered by load-bearing. To address this, animal models that enable the application of specific loads to individual bones have been developed. These are useful in defining how loading modulates (re)modeling and allow examination of the mechanisms that coordinate these events. This chapter describes how to apply mechanical loading to murine bones through points of articulation, which allows changes in endosteal, periosteal as well as trabecular bone to be revealed at multiple hierarchies, by a host of methodologies, including double fluorochrome labeling and computed tomography. In some instances, we consider how loads can be applied in order to allow responses in other components of the skeletal system to be examined.
Collapse
Affiliation(s)
- Dionysia Valkani
- Skeletal Biology Group, Comparative Biomedical Sciences, The Royal Veterinary College, London, UK
| | - Lucinda A E Evans
- Skeletal Biology Group, Comparative Biomedical Sciences, The Royal Veterinary College, London, UK
| | - Andrew A Pitsillides
- Skeletal Biology Group, Comparative Biomedical Sciences, The Royal Veterinary College, London, UK.
| |
Collapse
|
6
|
Khan OM, Gasperini W, Necessary C, Jacobs Z, Perry S, Rexroat J, Nelson K, Gamble P, Clements T, DeLeon M, Howard S, Zavala A, Farach-Carson M, Blaber E, Wu D, Satici A, Uzer G. Development and characterization of a low intensity vibrational system for microgravity studies. NPJ Microgravity 2024; 10:107. [PMID: 39567542 PMCID: PMC11579003 DOI: 10.1038/s41526-024-00444-x] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/18/2024] [Accepted: 10/24/2024] [Indexed: 11/22/2024] Open
Abstract
Extended-duration human spaceflight necessitates a better understanding of the physiological impacts of microgravity. While the ground-based microgravity simulations identified low intensity vibration (LIV) as a possible countermeasure, how cells may respond to LIV under real microgravity remain unexplored. In this way, adaptation of LIV bioreactors for space remains limited, resulting in a significant gap in microgravity research. In this study, we introduce an LIV bioreactor designed specifically for the usage in the International Space Station. Our research covers the bioreactor's design process and evaluation of the short-term viability of cells encapsulated in hydrogel-laden 3D printed scaffolds under 0.7 g, 90 Hz LIV. An LIV bioreactor compatible with the operation requirements of space missions provides a robust platform to study cellular effects of LIV under real microgravity conditions.
Collapse
Affiliation(s)
- Omor M Khan
- Department of Mechanical and Biomedical Engineering, Boise State University, Boise, ID, 83725, USA
| | - Will Gasperini
- Department of Mechanical and Biomedical Engineering, Boise State University, Boise, ID, 83725, USA
| | | | - Zach Jacobs
- Space Tango Inc, 611 Winchester, Lexington, KY, 40505, USA
| | - Sam Perry
- Space Tango Inc, 611 Winchester, Lexington, KY, 40505, USA
| | - Jason Rexroat
- Space Tango Inc, 611 Winchester, Lexington, KY, 40505, USA
| | - Kendall Nelson
- Space Tango Inc, 611 Winchester, Lexington, KY, 40505, USA
| | - Paul Gamble
- Space Tango Inc, 611 Winchester, Lexington, KY, 40505, USA
| | | | - Maximilien DeLeon
- Department of Bioengineering, Rice University, Houston, TX, 77005, USA
| | - Sean Howard
- Department of Mechanical and Biomedical Engineering, Boise State University, Boise, ID, 83725, USA
| | - Anamaria Zavala
- Department of Mechanical and Biomedical Engineering, Boise State University, Boise, ID, 83725, USA
| | | | - Elizabeth Blaber
- Center for Biotechnology and Rd. Interdisciplinary Studies, Department of Biomedical Engineering, Rensselaer Polytechnic Institute, Troy, NY, 12180, USA
| | - Danielle Wu
- Department of Bioengineering, Rice University, Houston, TX, 77005, USA
| | - Aykut Satici
- Department of Mechanical and Biomedical Engineering, Boise State University, Boise, ID, 83725, USA.
| | - Gunes Uzer
- Department of Mechanical and Biomedical Engineering, Boise State University, Boise, ID, 83725, USA.
| |
Collapse
|
7
|
Koneru MC, Harper CM. Comparing lateral plantar process trabecular structure to other regions of the human calcaneus. Anat Rec (Hoboken) 2024; 307:3152-3165. [PMID: 38357839 DOI: 10.1002/ar.25406] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/21/2023] [Revised: 01/22/2024] [Accepted: 01/28/2024] [Indexed: 02/16/2024]
Abstract
Investigating skeletal adaptations to bipedalism informs our understanding of form-function relationships. The calcaneus is an important skeletal element to study because it is a weight-bearing bone with a critical locomotor role. Although other calcaneal regions have been well studied, we lack a clear understanding of the functional role of the lateral plantar process (LPP). The LPP is a bony protuberance on the inferolateral portion of the calcaneus thought to aid the tuberosity in transmission of ground reaction forces during heel-strike. Here, we analyze LPP internal trabecular structure relative to other calcaneal regions to investigate its potential functional affinities. Human calcanei (n = 20) were micro-CT scanned, and weighted spherical harmonic analysis outputs were used to position 251 volumes of interest (VOI) within each bone. Trabecular thickness (Tb.Th), spacing (Tb.Sp), degree of anisotropy (DA), and bone volume fraction (BV/TV) were calculated for each VOI. Similarities in BV/TV and DA (p = 0.2741) between the LPP and inferior tuberosity support suggestions that the LPP is a weight-bearing structure that may transmit forces in a similar direction. The LPP significantly differs from the inferior tuberosity in Tb.Th and Tb.Sp (p < 0.05). Relatively thinner, more closely spaced trabeculae in the LPP may serve to increase internal surface area to compensate for its relatively small size compared to the tuberosity. Significant differences in all parameters between LPP and joint articular surfaces indicate that trabecular morphology is differently adapted for the transmission of forces associated with body mass through joints.
Collapse
Affiliation(s)
- Manisha C Koneru
- Department of Biomedical Sciences, Cooper Medical School of Rowan University, Camden, New Jersey, USA
| | - Christine M Harper
- Department of Biomedical Sciences, Cooper Medical School of Rowan University, Camden, New Jersey, USA
| |
Collapse
|
8
|
Pan C, Hao X, Deng X, Lu F, Liu J, Hou W, Xu T. The roles of Hippo/YAP signaling pathway in physical therapy. Cell Death Discov 2024; 10:197. [PMID: 38670949 PMCID: PMC11053014 DOI: 10.1038/s41420-024-01972-x] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/24/2024] [Revised: 04/16/2024] [Accepted: 04/17/2024] [Indexed: 04/28/2024] Open
Abstract
Cellular behavior is regulated by mechanical signals within the cellular microenvironment. Additionally, changes of temperature, blood flow, and muscle contraction also affect cellular state and the development of diseases. In clinical practice, physical therapy techniques such as ultrasound, vibration, exercise, cold therapy, and hyperthermia are commonly employed to alleviate pain and treat diseases. However, the molecular mechanism about how these physiotherapy methods stimulate local tissues and control gene expression remains unknow. Fortunately, the discovery of YAP filled this gap, which has been reported has the ability to sense and convert a wide variety of mechanical signals into cell-specific programs for transcription, thereby offering a fresh perspective on the mechanisms by which physiotherapy treat different diseases. This review examines the involvement of Hippo/YAP signaling pathway in various diseases and its role in different physical therapy approaches on diseases. Furthermore, we explore the potential therapeutic implications of the Hippo/YAP signaling pathway and address the limitations and controversies surrounding its application in physiotherapy.
Collapse
Affiliation(s)
- Chunran Pan
- Department of Rehabilitation, Tongji Hospital, Tongji Medical College, Huazhong University of Science and Technology, Wuhan, China
| | - Xiaoxia Hao
- Department of Rehabilitation, Tongji Hospital, Tongji Medical College, Huazhong University of Science and Technology, Wuhan, China
| | - Xiaofeng Deng
- Department of Rehabilitation, Tongji Hospital, Tongji Medical College, Huazhong University of Science and Technology, Wuhan, China
| | - Fan Lu
- Department of Orthopedics, Tongji Hospital, Tongji Medical College, Huazhong University of Science and Technology, Wuhan, China
| | - Jiawei Liu
- Department of Rehabilitation, Tongji Hospital, Tongji Medical College, Huazhong University of Science and Technology, Wuhan, China
| | - Wenjie Hou
- Department of Rehabilitation, Tongji Hospital, Tongji Medical College, Huazhong University of Science and Technology, Wuhan, China
| | - Tao Xu
- Department of Rehabilitation, Tongji Hospital, Tongji Medical College, Huazhong University of Science and Technology, Wuhan, China.
| |
Collapse
|
9
|
Regner AM, DeLeon M, Gibbons KD, Howard S, Nesbitt DQ, Lujan TJ, Fitzpatrick CK, Farach-Carson MC, Wu D, Uzer G. Increased deformations are dispensable for cell mechanoresponse in engineered bone analogs mimicking aging bone marrow. BIORXIV : THE PREPRINT SERVER FOR BIOLOGY 2023:2023.09.24.559187. [PMID: 37905032 PMCID: PMC10614733 DOI: 10.1101/2023.09.24.559187] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/02/2023]
Abstract
Aged individuals and astronauts experience bone loss despite rigorous physical activity. Bone mechanoresponse is in-part regulated by mesenchymal stem cells (MSCs) that respond to mechanical stimuli. Direct delivery of low intensity vibration (LIV) recovers MSC proliferation in senescence and simulated microgravity models, indicating that age-related reductions in mechanical signal delivery within bone marrow may contribute to declining bone mechanoresponse. To answer this question, we developed a 3D bone marrow analog that controls trabecular geometry, marrow mechanics and external stimuli. Validated finite element (FE) models were developed to quantify strain environment within hydrogels during LIV. Bone marrow analogs with gyroid-based trabeculae of bone volume fractions (BV/TV) corresponding to adult (25%) and aged (13%) mice were printed using polylactic acid (PLA). MSCs encapsulated in migration-permissive hydrogels within printed trabeculae showed robust cell populations on both PLA surface and hydrogel within a week. Following 14 days of LIV treatment (1g, 100 Hz, 1 hour/day), type-I collagen and F-actin were quantified for the cells in the hydrogel fraction. While LIV increased all measured outcomes, FE models predicted higher von Mises strains for the 13% BV/TV groups (0.2%) when compared to the 25% BV/TV group (0.1%). Despite increased strains, collagen-I and F-actin measures remained lower in the 13% BV/TV groups when compared to 25% BV/TV counterparts, indicating that cell response to LIV does not depend on hydrogel strains and that bone volume fraction (i.e. available bone surface) directly affects cell behavior in the hydrogel phase independent of the external stimuli. Overall, bone marrow analogs offer a robust and repeatable platform to study bone mechanobiology.
Collapse
Affiliation(s)
- Alexander M Regner
- Mechanical and Biomedical Engineering Department, Boise State University
| | - Maximilien DeLeon
- Department of Diagnostic and Biomedical Sciences, UTHealth Houston School of Dentistry
- Department of Bioengineering, Rice University
- Department of Biosciences, Rice University
| | - Kalin D. Gibbons
- Mechanical and Biomedical Engineering Department, Boise State University
| | - Sean Howard
- Mechanical and Biomedical Engineering Department, Boise State University
| | | | - Trevor J. Lujan
- Mechanical and Biomedical Engineering Department, Boise State University
| | | | - Mary C Farach-Carson
- Department of Diagnostic and Biomedical Sciences, UTHealth Houston School of Dentistry
- Department of Bioengineering, Rice University
- Department of Biosciences, Rice University
| | - Danielle Wu
- Department of Diagnostic and Biomedical Sciences, UTHealth Houston School of Dentistry
- Department of Bioengineering, Rice University
- Department of Biosciences, Rice University
| | - Gunes Uzer
- Mechanical and Biomedical Engineering Department, Boise State University
| |
Collapse
|
10
|
Choi D, Ishii T, Ishikawa M, Ootake T, Kamei H, Nagai K, Sueishi K. Vertical Vibration of Mouse Osteoblasts Promotes Cellular Differentiation and Cell Cycle Progression and Induces Aging In Vitro. Biomedicines 2023; 11:biomedicines11020444. [PMID: 36830981 PMCID: PMC9953217 DOI: 10.3390/biomedicines11020444] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/30/2022] [Revised: 01/29/2023] [Accepted: 01/31/2023] [Indexed: 02/05/2023] Open
Abstract
BACKGROUND This study aimed to investigate the effect of the vibration of osteoblasts on the cell cycle, cell differentiation, and aging. MATERIALS AND METHODS Primary maxilla osteoblasts harvested from eight-week-old mice were subjected to vibration at 3, 30, and 300 Hz once daily for 30 min; control group, 0 Hz. A cell proliferation assay and Cell-Clock Cell Cycle Assay were performed 24 h after vibration. Osteoblast differentiation assay, aging marker genes, SA-β-Gal activity, and telomere length (qPCR) were assayed two weeks post- vibration once every two days. RESULTS Cell proliferation increased significantly at 30 and 300 Hz rather than 0 Hz. Several cells were in the late G2/M stage of the cell cycle at 30 Hz. The osteoblast differentiation assay was significantly higher at 30 Hz than at 0 Hz. Runx2 mRNA was downregulated at 30 Hz compared to that at 0 Hz, while osteopontin, osteocalcin, and sclerostin mRNA were upregulated. p53/p21, p16, and c-fos were activated at 30 Hz. SA-β-Gal activity increased significantly at 30 or 300 Hz. Telomere length was significantly lower at 30 or 300 Hz. CONCLUSIONS The results suggest that providing optimal vibration to osteoblasts promotes cell cycle progression and differentiation and induces cell aging.
Collapse
Affiliation(s)
- Daehwan Choi
- Department of Orthodontics, Tokyo Dental College, 2-9-18, KandaMisaki-Cho, Chiyoda-ku, Tokyo 101-0061, Japan
| | - Takenobu Ishii
- Department of Orthodontics, Tokyo Dental College, 2-9-18, KandaMisaki-Cho, Chiyoda-ku, Tokyo 101-0061, Japan
- Department of Orthodontics, Tokyo Dental College Chiba Dental Center, 1-2-2, Masago, Mihama-ku, Chiba 261-0011, Japan
- Correspondence: ; Tel.: +81-03-5375-1724
| | - Munetada Ishikawa
- Department of Orthodontics, Tokyo Dental College, 2-9-18, KandaMisaki-Cho, Chiyoda-ku, Tokyo 101-0061, Japan
| | - Tomohisa Ootake
- Department of Orthodontics, Tokyo Dental College, 2-9-18, KandaMisaki-Cho, Chiyoda-ku, Tokyo 101-0061, Japan
| | - Hirokazu Kamei
- Department of Orthodontics, Tokyo Dental College, 2-9-18, KandaMisaki-Cho, Chiyoda-ku, Tokyo 101-0061, Japan
| | - Kohei Nagai
- Department of Orthodontics, Tokyo Dental College, 2-9-18, KandaMisaki-Cho, Chiyoda-ku, Tokyo 101-0061, Japan
| | - Kenji Sueishi
- Department of Orthodontics, Tokyo Dental College, 2-9-18, KandaMisaki-Cho, Chiyoda-ku, Tokyo 101-0061, Japan
- Department of Orthodontics, Tokyo Dental College Chiba Dental Center, 1-2-2, Masago, Mihama-ku, Chiba 261-0011, Japan
| |
Collapse
|
11
|
Nix Z, Kota D, Ratnayake I, Wang C, Smith S, Wood S. Spectral characterization of cell surface motion for mechanistic investigations of cellular mechanobiology. PROGRESS IN BIOPHYSICS AND MOLECULAR BIOLOGY 2022; 176:3-15. [PMID: 36108781 DOI: 10.1016/j.pbiomolbio.2022.08.002] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 12/14/2021] [Revised: 07/27/2022] [Accepted: 08/05/2022] [Indexed: 06/15/2023]
Abstract
Understanding the specific mechanisms responsible for anabolic and catabolic responses to static or dynamic force are largely poorly understood. Because of this, most research groups studying mechanotransduction due to dynamic forces employ an empirical approach in deciding what frequencies to apply during experiments. While this has been shown to elucidate valuable information regarding how cells respond under controlled provocation, it is often difficult or impossible to determine a true optimal frequency for force application, as many intracellular complexes are involved in receiving, propagating, and responding to a given stimulus. Here we present a novel adaptation of an analytical technique from the fields of civil and mechanical engineering that may open the door to direct measurement of mechanobiological cellular frequencies which could be used to target specific cell signaling pathways leveraging synergy between outside-in and inside-out mechanotransduction approaches. This information could be useful in identifying how specific proteins are involved in the homeostatic balance, or disruption thereof, of cells and tissue, furthering the understanding of the pathogenesis and progression of many diseases across a wide variety of cell types, which may one day lead to the development of novel mechanobiological therapies for clinical use.
Collapse
Affiliation(s)
- Zachary Nix
- Department of Nanoscience & Biomedical Engineering, BioSystems Networks / Translational Research (BioSNTR), South Dakota School of Mines and Technology, USA
| | - Divya Kota
- Department of Nanoscience & Biomedical Engineering, BioSystems Networks / Translational Research (BioSNTR), South Dakota School of Mines and Technology, USA
| | - Ishara Ratnayake
- Department of Nanoscience & Biomedical Engineering, BioSystems Networks / Translational Research (BioSNTR), South Dakota School of Mines and Technology, USA
| | - Congzhou Wang
- Department of Nanoscience & Biomedical Engineering, BioSystems Networks / Translational Research (BioSNTR), South Dakota School of Mines and Technology, USA
| | - Steve Smith
- Department of Nanoscience & Biomedical Engineering, BioSystems Networks / Translational Research (BioSNTR), South Dakota School of Mines and Technology, USA
| | - Scott Wood
- Department of Nanoscience & Biomedical Engineering, BioSystems Networks / Translational Research (BioSNTR), South Dakota School of Mines and Technology, USA.
| |
Collapse
|
12
|
Abstract
This Perspectives provides a back-to-basics rationale for the ideal exercise prescription for osteoporosis. The relevance of fundamental principles of mechanical loading and bone adaptation determined from early animal studies is revisited. The application to human trials is presented, including recent advances. A model of broadscale implementation is described, and areas for further investigation are identified.
Collapse
Affiliation(s)
- Belinda R Beck
- Griffith University, Gold Coast, and The Bone Clinic, Coorparoo, QLD, Australia
| |
Collapse
|
13
|
BASKAN OZNUR, OZCIVICI ENGIN. VIABILITY OF 3T3-L1 PREADIPOCYTES IS MODULATED BY THE APPLIED FREQUENCY BUT NOT THE EXPOSURE DURATION OF LOW INTENSITY VIBRATORY STIMULATION. J MECH MED BIOL 2022. [DOI: 10.1142/s0219519422500063] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/18/2022]
Abstract
Mechanical forces are the integral determinants in cell and tissue homeostasis and regeneration, and they can affect numerous biological process from proliferation to fate determination. Mechanical forces that possess low magnitude and high frequency characteristics are also known as low intensity vibrations (LIVs). These signals were studied widely on many cell types for regenerative purposes, however most of these studies select components of LIV signals (e.g., magnitude, frequency, duration, etc.) arbitrarily. Here, we addressed the effect of LIV applied frequency, LIV daily exposure time and fate induction on the viability of preadipocyte 3T3-L1 cells. For this, we performed a frequency sweep that was ranging from 30[Formula: see text]Hz to 120[Formula: see text]Hz with 15[Formula: see text]Hz increments applied for 5, 10 or 20[Formula: see text]min during quiescent growth or adipogenesis for up to 10 days. Results suggest that the applied frequency and fate induction was an important determinant of cell viability while daily exposure time had no effect. These findings contribute to the effort of optimizing a relevant mechanical stimulus that can inhibit adipogenesis.
Collapse
Affiliation(s)
- OZNUR BASKAN
- Department of Bioengineering, Izmir Institute of Technology Urla, Izmir 35430, Turkey
| | - ENGIN OZCIVICI
- Department of Bioengineering, Izmir Institute of Technology Urla, Izmir 35430, Turkey
| |
Collapse
|
14
|
Saers JPP, Gordon AD, Ryan TM, Stock JT. Growth and development of trabecular structure in the calcaneus of Japanese macaques (Macaca fuscata) reflects locomotor behavior, life history, and neuromuscular development. J Anat 2022; 241:67-81. [PMID: 35178713 PMCID: PMC9178394 DOI: 10.1111/joa.13641] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/29/2021] [Revised: 01/26/2022] [Accepted: 01/28/2022] [Indexed: 11/30/2022] Open
Abstract
Bone structure dynamically adapts to its mechanical environment throughout ontogeny by altering the structure of trabecular bone, the three-dimensional mesh-like structure found underneath joint surfaces. Trabecular structure, then, can provide a record of variation in loading directions and magnitude; and in ontogenetic samples, it can potentially be used to track developmental shifts in limb posture. We aim to broaden the analysis of trabecular bone ontogeny by incorporating interactions between ontogenetic variation in locomotor repertoire, neuromuscular maturation, and life history. We examine the associations between these variables and age-related variation in trabecular structure in the calcaneus of Japanese macaques (Macaca fuscata). We used high-resolution micro-computed tomography scanning to image the calcaneus in a cross-sectional sample of 34 juvenile M. fuscata aged between 0 and 7 years old at the Primate Research Institute, Japan. We calculated whole bone averages of standard trabecular properties and generated whole-bone morphometric maps of bone volume fraction and Young's modulus. Trabecular structure becomes increasingly heterogeneous in older individuals. Bone volume fraction (BV/total volume [TV]) decreases during the first month of life and increases afterward, coinciding with the onset of independent locomotion in M. fuscata. At birth, primary Young's modulus is oriented orthogonal to the ossification center, but after locomotor onset bone structure becomes stiffest in the direction of joint surfaces and muscle attachments. Age-related variation in bone volume fraction is best predicted by an interaction between the estimated percentage of adult brain size, body mass, and locomotor onset. To explain our findings, we propose a model where interactions between age-related increases in body weight and maturation of the neuromuscular system alter the loading environment of the calcaneus, to which the internal trabecular structure dynamically adapts. This model cannot be directly tested based on our cross-sectional data. However, confirmation of the model by longitudinal experiments and in multiple species would show that trabecular structure can be used both to infer behavior from fossil morphology and serve as a valuable proxy for neuromuscular maturation and life history events like locomotor onset and the achievement of an adult-like gait. This approach could significantly expand our knowledge of the biology and behavior of fossil species.
Collapse
Affiliation(s)
- Jaap P P Saers
- Department of Archaeology, Cambridge University, Cambridge, UK
| | - Adam D Gordon
- Department of Anthropology, University at Albany, SUNY, Albany, New York, USA
| | - Timothy M Ryan
- Department of Anthropology, Pennsylvania State University, State College, Pennsylvania, USA
| | - Jay T Stock
- Department of Archaeology, Cambridge University, Cambridge, UK.,Department of Anthropology, Western University, London, Ontario, Canada
| |
Collapse
|
15
|
Cho H, Park HJ, Seo YK. Induction of PLXNA4 Gene during Neural Differentiation in Human Umbilical-Cord-Derived Mesenchymal Stem Cells by Low-Intensity Sub-Sonic Vibration. Int J Mol Sci 2022; 23:ijms23031522. [PMID: 35163445 PMCID: PMC8835879 DOI: 10.3390/ijms23031522] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/24/2021] [Revised: 01/22/2022] [Accepted: 01/27/2022] [Indexed: 02/01/2023] Open
Abstract
Human umbilical-cord-derived mesenchymal stem cells (hUC-MSC) are a type of mesenchymal stem cells and are more primitive than other MSCs. In this study, we identify novel genes and signal-activating proteins involved in the neural differentiation of hUC-MSCs induced by Low-Intensity Sub-Sonic Vibration (LISSV). RNA sequencing was used to find genes involved in the differentiation process by LISSV. The changes in hUC-MSCs caused by LISSV were confirmed by PLXNA4 overexpression and gene knockdown through small interfering RNA experiments. The six genes were increased among genes related to neurons and the nervous system. One of them, the PLXNA4 gene, is known to play a role as a guide for axons in the development of the nervous system. When the PLXNA4 recombinant protein was added, neuron-related genes were increased. In the PLXNA4 gene knockdown experiment, the expression of neuron-related genes was not changed by LISSV exposure. The PLXNA4 gene is activated by sema family ligands. The expression of SEMA3A was increased by LISSV, and its downstream signaling molecule, FYN, was also activated. We suggest that the PLXNA4 gene plays an important role in hUC-MSC neuronal differentiation through exposure to LISSV. The differentiation process depends on SEMA3A-PLXNA4-dependent FYN activation in hUC-MSCs.
Collapse
Affiliation(s)
- Hyunjin Cho
- Research Institute of Integrative Life Sciences, Dongguk University, Goyang-si 10326, Korea;
| | - Hee-Jung Park
- Department of Medical Biotechnology (BK21 Plus Team), Dongguk University, Goyang-si 10326, Korea;
| | - Young-Kwon Seo
- Department of Medical Biotechnology (BK21 Plus Team), Dongguk University, Goyang-si 10326, Korea;
- Correspondence:
| |
Collapse
|
16
|
Beck B, Rubin C, Harding A, Paul S, Forwood M. The effect of low-intensity whole-body vibration with or without high-intensity resistance and impact training on risk factors for proximal femur fragility fracture in postmenopausal women with low bone mass: study protocol for the VIBMOR randomized controlled trial. Trials 2022; 23:15. [PMID: 34991684 PMCID: PMC8734256 DOI: 10.1186/s13063-021-05911-4] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/25/2021] [Accepted: 12/03/2021] [Indexed: 11/24/2022] Open
Abstract
BACKGROUND The prevailing medical opinion is that medication is the primary (some might argue, only) effective intervention for osteoporosis. It is nevertheless recognized that osteoporosis medications are not universally effective, tolerated, or acceptable to patients. Mechanical loading, such as vibration and exercise, can also be osteogenic but the degree, relative efficacy, and combined effect is unknown. The purpose of the VIBMOR trial is to determine the efficacy of low-intensity whole-body vibration (LIV), bone-targeted, high-intensity resistance and impact training (HiRIT), or the combination of LIV and HiRIT on risk factors for hip fracture in postmenopausal women with osteopenia and osteoporosis. METHODS Postmenopausal women with low areal bone mineral density (aBMD) at the proximal femur and/or lumbar spine, with or without a history of fragility fracture, and either on or off osteoporosis medications will be recruited. Eligible participants will be randomly allocated to one of four trial arms for 9 months: LIV, HiRIT, LIV + HiRIT, or control (low-intensity, home-based exercise). Allocation will be block-randomized, stratified by use of osteoporosis medications. Testing will be performed at three time points: baseline (T0), post-intervention (T1; 9 months), and 1 year thereafter (T2; 21 months) to examine detraining effects. The primary outcome measure will be total hip aBMD determined by dual-energy X-ray absorptiometry (DXA). Secondary outcomes will include aBMD at other regions, anthropometrics, and other indices of bone strength, body composition, physical function, kyphosis, muscle strength and power, balance, falls, and intervention compliance. Exploratory outcomes include bone turnover markers, pelvic floor health, quality of life, physical activity enjoyment, adverse events, and fracture. An economic evaluation will also be conducted. DISCUSSION No previous studies have compared the effect of LIV alone or in combination with bone-targeted HiRIT (with or without osteoporosis medications) on risk factors for hip fracture in postmenopausal women with low bone mass. Should either, both, or combined mechanical interventions be safe and efficacious, alternative therapeutic avenues will be available to individuals at elevated risk of fragility fracture who are unresponsive to or unwilling or unable to take osteoporosis medications. TRIAL REGISTRATION Australian New Zealand Clinical Trials Registry (www. anzctr.org.au ) (Trial number ANZCTR12615000848505, https://www.anzctr.org.au/Trial/Registration/TrialReview.aspx?id = 368962 ); date of registration 14/08/2015 (prospectively registered). Universal Trial Number: U1111-1172-3652.
Collapse
Affiliation(s)
- Belinda Beck
- Menzies Health Institute Queensland, School of Health Sciences and Social Work, Griffith University, Gold Coast, QLD Australia
| | - Clinton Rubin
- Department of Biomedical Engineering, State University of New York at Stony Brook, New York, NY USA
| | - Amy Harding
- Menzies Health Institute Queensland, School of Health Sciences and Social Work, Griffith University, Gold Coast, QLD Australia
| | - Sanjoy Paul
- Melbourne EpiCentre, University of Melbourne and Melbourne Health, Melbourne, VIC Australia
| | - Mark Forwood
- School of Pharmacy and Medical Sciences, Gold Coast, QLD Australia
| |
Collapse
|
17
|
Abstract
The nuclear envelope and nucleoskeleton are emerging as signaling centers that regulate how physical information from the extracellular matrix is biochemically transduced into the nucleus, affecting chromatin and controlling cell function. Bone is a mechanically driven tissue that relies on physical information to maintain its physiological function and structure. Disorder that present with musculoskeletal and cardiac symptoms, such as Emery-Dreifuss muscular dystrophies and progeria, correlate with mutations in nuclear envelope proteins including Linker of Nucleoskeleton and Cytoskeleton (LINC) complex, Lamin A/C, and emerin. However, the role of nuclear envelope mechanobiology on bone function remains underexplored. The mesenchymal stem cell (MSC) model is perhaps the most studied relationship between bone regulation and nuclear envelope function. MSCs maintain the musculoskeletal system by differentiating into multiple cell types including osteocytes and adipocytes, thus supporting the bone's ability to respond to mechanical challenge. In this review, we will focus on how MSC function is regulated by mechanical challenges both in vitro and in vivo within the context of bone function specifically focusing on integrin, β-catenin and YAP/TAZ signaling. The importance of the nuclear envelope will be explored within the context of musculoskeletal diseases related to nuclear envelope protein mutations and nuclear envelope regulation of signaling pathways relevant to bone mechanobiology in vitro and in vivo.
Collapse
Affiliation(s)
- Scott Birks
- Boise State University, Micron School of Materials Science and Engineering, United States of America
| | - Gunes Uzer
- Boise State University, Mechanical and Biomedical Engineering, United States of America.
| |
Collapse
|
18
|
Long-term Effects of Mechanical Vibration Stimulus on the Bone Formation of Wistar Rats: An Assessment Method Based on X-rays Images. Acad Radiol 2021; 28:e240-e245. [PMID: 32624402 DOI: 10.1016/j.acra.2020.05.035] [Citation(s) in RCA: 8] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/06/2020] [Revised: 05/25/2020] [Accepted: 05/28/2020] [Indexed: 01/03/2023]
Abstract
BACKGROUND Bone is a complex living tissue that adapts itself to the demands of mechanical stimuli such as physical activity and exercise. Whole-body vibration (WBV) is a type of exercise characterized by the transmission of mechanical vibration stimuli produced by a vibrating platform. This study aimed to investigated, in experimental model, the effect of WBV exercise on the bone in different frequencies through X-ray analysis. MATERIALS AND METHODS Wistar rats were divided in three groups: control, exposed to WBV of 10 Hz and exposed to WBV of 20 Hz, during 8-weeks. All procedures to obtain the radiographic images were carried out before and after the experiments. The femur linear size and bone density measurements through radiographic images were performed in all animals. A factor of increase for bone density (FIBD) was determined. RESULTS No differences were observed in the qualitative comparison between the groups, as well as radiographic bone density before the experiment. However, after the experiment the bone density increased in the rats exposed to WBV of 10 Hz and 20 Hz compared to control group. Also, the FIBD was higher in the groups exposed to WBV in comparison with control. CONCLUSION These findings indicate an increase of the bone density dependent of the vibration stimulus frequency. In addition, this increase suggests a possible osteogenic effect to the mechanical vibrations of 10 and 20 Hz.
Collapse
|
19
|
Three-dimensional imaging and molecular analysis of the effects of photobiomodulation and mechanical vibration on orthodontic retention treatment in rats : Effects of photobiomodulation and mechanical vibration on orthodontic retention treatment. J Orofac Orthop 2021; 83:24-41. [PMID: 34009424 DOI: 10.1007/s00056-021-00296-0] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/26/2020] [Accepted: 03/15/2021] [Indexed: 10/21/2022]
Abstract
PURPOSE We aimed to evaluate and compare effects of photobiomodulation (PBM) and low-magnitude high-frequency mechanical vibration (HFMV) on orthodontic retention. METHODS Sixty-four female Wistar albino rats were divided into 9 groups (2 negative and positive controls each, 3 PBM and 2 HFMV groups) and studied for 25 days. In the experimental groups, closed nickel-titanium closed coil springs with a 50 cN force were placed for 10 days between the maxillary incisor and molar. PBM and HFMV were applied daily over long- (15 days) and short-term (7 days) retention periods. The PBM groups received PBM with a single wavelength (650 nm) or higher wavelengths (532, 650, 940 nm) for 9 min per day. HFMV groups received HFMV of 10, 20, and 30 Hz for 10 min per day. Right and left maxilla were assessed using micro-computed tomography imaging and real-time polymerase chain reaction. The amount of tooth movement during the retention period, expression levels of cyclooxygenase‑2 (COX-2), osteoprotegerin (OPG), and receptor activator of nuclear factor-kappa B ligand (RANKL) mRNA gene expression levels, OPG/RANKL ratios, alveolar bone trabecular thickness (Tb.Th), trabecular number (Tb.N), and structure model index were analyzed. Kruskal-Wallis and Mann-Whitney U tests were used for multiple comparisons of the nonparametric distributed data and binary comparisons, respectively. RESULTS When using the long-term retention protocol, PBM and HFMV treatment increased Tb.N (p < 0.05) and decreased COX‑2 mRNA gene expression levels (p < 0.05) and Tb.Th (p < 0.05) compared to controls. For short-term retention, PBM and HFMV decreased the amount of relapse tooth movement compared to controls. In addition, Tb.Th (p < 0.05) and the mRNA gene expression levels of COX‑2 and RANKL (p < 0.05) were decreased. CONCLUSION PBM and HFMV might be able to support retention after orthodontic tooth movement by reducing bone resorption and increasing bone quality.
Collapse
|
20
|
Rajapakse CS, Johncola AJ, Batzdorf AS, Jones BC, Al Mukaddam M, Sexton K, Shults J, Leonard MB, Snyder PJ, Wehrli FW. Effect of Low-Intensity Vibration on Bone Strength, Microstructure, and Adiposity in Pre-Osteoporotic Postmenopausal Women: A Randomized Placebo-Controlled Trial. J Bone Miner Res 2021; 36:673-684. [PMID: 33314313 DOI: 10.1002/jbmr.4229] [Citation(s) in RCA: 13] [Impact Index Per Article: 3.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 08/16/2020] [Revised: 11/21/2020] [Accepted: 11/27/2020] [Indexed: 12/31/2022]
Abstract
There has been evidence that cyclical mechanical stimulation may be osteogenic, thus providing opportunities for nonpharmacological treatment of degenerative bone disease. Here, we applied this technology to a cohort of postmenopausal women with varying bone mineral density (BMD) T-scores at the total hip (-0.524 ± 0.843) and spine (-0.795 ± 1.03) to examine the response to intervention after 1 year of daily treatment with 10 minutes of vibration therapy in a randomized double-blinded trial. The device operates either in an active mode (30 Hz and 0.3 g) or placebo. Primary endpoints were changes in bone stiffness at the distal tibia and marrow adiposity of the vertebrae, based on 3 Tesla high-resolution MRI and spectroscopic imaging, respectively. Secondary outcome variables included distal tibial trabecular microstructural parameters and vertebral deformity determined by MRI, volumetric and areal bone densities derived using peripheral quantitative computed tomography (pQCT) of the tibia, and dual-energy X-ray absorptiometry (DXA)-based BMD of the hip and spine. Device adherence was 83% in the active group (n = 42) and 86% in the placebo group (n = 38) and did not differ between groups (p = .7). The mean 12-month changes in tibial stiffness in the treatment group and placebo group were +1.31 ± 6.05% and -2.55 ± 3.90%, respectively (group difference 3.86%, p = .0096). In the active group, marrow fat fraction significantly decreased after 12 months of intervention (p = .0003), whereas no significant change was observed in the placebo group (p = .7; group difference -1.59%, p = .029). Mean differences of the changes in trabecular bone volume fraction (p = .048) and erosion index (p = .044) were also significant, as was pQCT-derived trabecular volumetric BMD (vBMD; p = .016) at the tibia. The data are commensurate with the hypothesis that vibration therapy is protective against loss in mechanical strength and, further, that the intervention minimizes the shift from the osteoblastic to the adipocytic lineage of mesenchymal stem cells. © 2020 American Society for Bone and Mineral Research (ASBMR).
Collapse
Affiliation(s)
- Chamith S Rajapakse
- Department of Radiology, University of Pennsylvania, Philadelphia, PA, USA.,Department of Orthopaedic Surgery, University of Pennsylvania, Philadelphia, PA, USA
| | - Alyssa J Johncola
- Department of Radiology, University of Pennsylvania, Philadelphia, PA, USA
| | | | - Brandon C Jones
- Department of Radiology, University of Pennsylvania, Philadelphia, PA, USA
| | - Mona Al Mukaddam
- Department of Orthopaedic Surgery, University of Pennsylvania, Philadelphia, PA, USA.,Department of Medicine, University of Pennsylvania, Philadelphia, PA, USA
| | - Kelly Sexton
- Department of Radiology, University of Pennsylvania, Philadelphia, PA, USA
| | - Justine Shults
- Department of Biostatistics, Epidemiology, and Informatics, University of Pennsylvania, Philadelphia, PA, USA
| | - Mary B Leonard
- Department of Pediatrics, Children's Hospital of Philadelphia, University of Pennsylvania, Philadelphia, PA, USA.,Department of Pediatrics, Stanford University School of Medicine, Stanford, CA, USA
| | - Peter J Snyder
- Department of Medicine, University of Pennsylvania, Philadelphia, PA, USA
| | - Felix W Wehrli
- Department of Radiology, University of Pennsylvania, Philadelphia, PA, USA
| |
Collapse
|
21
|
Thompson M, Woods K, Newberg J, Oxford JT, Uzer G. Low-intensity vibration restores nuclear YAP levels and acute YAP nuclear shuttling in mesenchymal stem cells subjected to simulated microgravity. NPJ Microgravity 2020; 6:35. [PMID: 33298964 PMCID: PMC7708987 DOI: 10.1038/s41526-020-00125-5] [Citation(s) in RCA: 29] [Impact Index Per Article: 5.8] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/26/2020] [Accepted: 10/08/2020] [Indexed: 12/18/2022] Open
Abstract
Reducing the musculoskeletal deterioration that astronauts experience in microgravity requires countermeasures that can improve the effectiveness of otherwise rigorous and time-expensive exercise regimens in space. The ability of low-intensity vibrations (LIV) to activate force-responsive signaling pathways in cells suggests LIV as a potential countermeasure to improve cell responsiveness to subsequent mechanical challenge. Mechanoresponse of mesenchymal stem cells (MSC), which maintain bone-making osteoblasts, is in part controlled by the "mechanotransducer" protein YAP (Yes-associated protein), which is shuttled into the nucleus in response to cyto-mechanical forces. Here, using YAP nuclear shuttling as a measurement outcome, we tested the effect of 72 h of clinostat-induced simulated microgravity (SMG) and daily LIV application (LIVDT) on the YAP nuclear entry driven by either acute LIV (LIVAT) or Lysophosphohaditic acid (LPA), applied after the 72 h period. We hypothesized that SMG-induced impairment of acute YAP nuclear entry would be alleviated by the daily application of LIVDT. Results showed that while both acute LIVAT and LPA treatments increased nuclear YAP entry by 50 and 87% over the basal levels in SMG-treated MSCs, nuclear YAP levels of all SMG groups were significantly lower than non-SMG controls. LIVDT, applied in parallel to SMG, restored the SMG-driven decrease in basal nuclear YAP to control levels as well as increased the LPA-induced but not LIVAT-induced YAP nuclear entry over SMG only, counterparts. These cell-level observations suggest that daily LIV treatments are a feasible countermeasure for restoring basal nuclear YAP levels and increasing the YAP nuclear shuttling in MSCs under SMG.
Collapse
Affiliation(s)
- Matthew Thompson
- Mechanical and Biomedical Engineering, Boise State University, Boise, ID, USA
| | - Kali Woods
- Biomolecular Sciences Graduate Program, Boise State University, Boise, ID, USA
| | - Joshua Newberg
- Mechanical and Biomedical Engineering, Boise State University, Boise, ID, USA
| | - Julia Thom Oxford
- Biomolecular Sciences Graduate Program, Boise State University, Boise, ID, USA
| | - Gunes Uzer
- Mechanical and Biomedical Engineering, Boise State University, Boise, ID, USA.
| |
Collapse
|
22
|
Saers JPP, DeMars LJ, Stephens NB, Jashashvili T, Carlson KJ, Gordon AD, Shaw CN, Ryan TM, Stock JT. Combinations of trabecular and cortical bone properties distinguish various loading modalities between athletes and controls. AMERICAN JOURNAL OF PHYSICAL ANTHROPOLOGY 2020; 174:434-450. [PMID: 33244746 DOI: 10.1002/ajpa.24176] [Citation(s) in RCA: 11] [Impact Index Per Article: 2.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 04/17/2020] [Revised: 08/06/2020] [Accepted: 11/03/2020] [Indexed: 12/21/2022]
Abstract
OBJECTIVES Variation in trabecular and cortical bone properties is often used to infer habitual behavior in the past. However, the structures of both types of bone are rarely considered together and may even contradict each other in functional interpretations. We examine trabecular and cortical bone properties in various athletes and sedentary controls to clarify the associations between combinations of cortical and trabecular bone properties and various loading modalities. MATERIALS AND METHODS We compare trabecular and cortical bone properties using peripheral quantitative computed tomography scans of the tibia between groups of 83 male athletes (running, hockey, swimming, cricket) and sedentary controls using Bayesian multilevel models. We quantify midshaft cortical bone rigidity and area (J, CA), midshaft shape index (Imax/Imin), and mean trabecular bone mineral density (BMD) in the distal tibia. RESULTS All groups show unique combinations of biomechanical properties. Cortical bone rigidity is high in sports that involve impact loading (cricket, running, hockey) and low in nonimpact loaded swimmers and controls. Runners have more anteroposteriorly elliptical midshafts compared to other groups. Interestingly, all athletes have greater trabecular BMD compared to controls, but do not differ credibly among each other. DISCUSSION Results suggest that cortical midshaft hypertrophy is associated with impact loading while trabecular BMD is positively associated with both impact and nonimpact loading. Midshaft shape is associated with directionality of loading. Individuals from the different categories overlap substantially, but group means differ credibly, suggesting that nuanced group-level inferences of habitual behavior are possible when combinations of trabecular and cortical bone are analyzed.
Collapse
Affiliation(s)
- Jaap P P Saers
- Department of Archaeology, Cambridge University, Cambridge, Cambridgeshire, United Kingdom of Great Britain and Northern Ireland
| | - Lily J DeMars
- Department of Anthropology, Pennsylvania State University, University Park, Pennsylvania, USA
| | - Nicholas B Stephens
- Department of Anthropology, Pennsylvania State University, University Park, Pennsylvania, USA
| | - Tea Jashashvili
- Department of Integrative Anatomical Sciences, Keck School of Medicine, University of Southern California, Los Angeles, California, USA.,Department of Geology and Paleontology, Georgian National Museum, Tbilisi, Georgia
| | - Kristian J Carlson
- Department of Integrative Anatomical Sciences, Keck School of Medicine, University of Southern California, Los Angeles, California, USA.,Evolutionary Studies Institute, University of the Witwatersrand, Johannesburg, South Africa
| | - Adam D Gordon
- Department of Anthropology, University at Albany, SUNY, Albany, New York, USA
| | | | - Timothy M Ryan
- Department of Anthropology, Pennsylvania State University, University Park, Pennsylvania, USA
| | - Jay T Stock
- Department of Archaeology, Cambridge University, Cambridge, Cambridgeshire, United Kingdom of Great Britain and Northern Ireland.,Department of Anthropology, Western University, London, Ontario, Canada
| |
Collapse
|
23
|
Kumar V, Batra P, Sharma K, Raghavan S, Srivastava A. Comparative assessment of the rate of orthodontic tooth movement in adolescent patients undergoing treatment by first bicuspid extraction and en mass retraction, associated with low-frequency mechanical vibrations in passive self-ligating and conventional brackets: A randomized controlled trial. Int Orthod 2020; 18:696-705. [PMID: 33162347 DOI: 10.1016/j.ortho.2020.08.003] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/17/2020] [Revised: 08/07/2020] [Accepted: 08/07/2020] [Indexed: 01/10/2023]
Abstract
BACKGROUND Low-frequency vibrations are one of the many non-surgical modalities aimed at increasing the rate of orthodontic tooth movement. OBJECTIVE The present trial was conducted to assess the efficacy of low-frequency vibrations in increasing the rate of orthodontic tooth movement in adolescent patients undergoing fixed mechanotherapy with passive self-ligating brackets and conventional brackets. MATERIALS AND METHODS Setting and sample population: department of orthodontics and dentofacial orthopaedics in a nationally accredited dental college. Participants, study design and methods: 65 patients were randomly allocated to three groups. Two experimental groups consisted of passive self-ligating and conventionally ligated appliances received low-frequency vibrations. The control group did not receive any vibrations. Allocation ratio was 1:1:1.32. Eligibility criteria: adolescent patients with sound and healthy dentition, incisor irregularity<5mm. PRIMARY OUTCOME rate of orthodontic tooth movement in mm/month. Randomization and blinding: computer-generated random allocation sequencing was done and data assessor was blinded. STATISTICS the Q-Q plot and Shapiro-Wilks test judged the normality of the data. The parametric test included ANCOVA and post-hoc analysis. RESULTS No statistically significant enhancement of tooth movement was seen in the experimental groups, when comparison was done with the control group P>0.05. Comparison between the two experimental groups did not reveal any significant difference either. CONCLUSION No statistically significant increase of orthodontic tooth movement was seen with low-frequency vibrations and the mode of ligation did not have any effect in increasing the rate of tooth movement either.
Collapse
Affiliation(s)
- Vaibhav Kumar
- Institute of Dental Sciences and Technologies, Department of Orthodontics and Dentofacial Orthopedics, NH-58, Kadarabad, ModiNagar, Ghaziabad UP, India
| | - Puneet Batra
- Institute of Dental Sciences and Technologies, Department of Orthodontics and Dentofacial Orthopedics, NH-58, Kadarabad, ModiNagar, Ghaziabad UP, India
| | - Karan Sharma
- Institute of Dental Sciences and Technologies, Department of Orthodontics and Dentofacial Orthopedics, NH-58, Kadarabad, ModiNagar, Ghaziabad UP, India.
| | - Sreevatsan Raghavan
- Institute of Dental Sciences and Technologies, Department of Orthodontics and Dentofacial Orthopedics, NH-58, Kadarabad, ModiNagar, Ghaziabad UP, India
| | - Amit Srivastava
- Institute of Dental Sciences and Technologies, Department of Orthodontics and Dentofacial Orthopedics, NH-58, Kadarabad, ModiNagar, Ghaziabad UP, India
| |
Collapse
|
24
|
Bioinspired material architectures from bighorn sheep horncore velar bone for impact loading applications. Sci Rep 2020; 10:18916. [PMID: 33144662 PMCID: PMC7642289 DOI: 10.1038/s41598-020-76021-5] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/24/2020] [Accepted: 10/19/2020] [Indexed: 11/12/2022] Open
Abstract
Rocky Mountain bighorn sheep rams (Ovis canadensis canadensis) routinely conduct intraspecific combat where high energy cranial impacts are experienced. Previous studies have estimated cranial impact forces to be up to 3400 N during ramming, and prior finite element modeling studies showed the bony horncore stores 3 × more strain energy than the horn during impact. In the current study, the architecture of the porous bone within the horncore was quantified, mimicked, analyzed by finite element modeling, fabricated via additive manufacturing, and mechanically tested to determine the suitability of the novel bioinspired material architecture for use in running shoe midsoles. The iterative biomimicking design approach was able to tailor the mechanical behavior of the porous bone mimics. The approach produced 3D printed mimics that performed similarly to ethylene–vinyl acetate shoe materials in quasi-static loading. Furthermore, a quadratic relationship was discovered between impact force and stiffness in the porous bone mimics, which indicates a range of stiffness values that prevents impact force from becoming excessively high. These findings have implications for the design of novel bioinspired material architectures for minimizing impact force.
Collapse
|
25
|
Zhou H, Trudel G, Alexeev K, Laneuville O. Reversibility of marrow adipose accumulation and reduction of trabecular bone in the epiphysis of the proximal tibia. Acta Histochem 2020; 122:151604. [PMID: 33066832 DOI: 10.1016/j.acthis.2020.151604] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/12/2020] [Revised: 07/28/2020] [Accepted: 08/04/2020] [Indexed: 02/07/2023]
Abstract
Mechanical stimuli play an important role in the homeostasis of trabecular bone and marrow adipose tissue, particularly for the weight-bearing skeleton. Prolonged immobilization and disuse have been shown to reduce trabecular bone content and increase marrow adipose tissue in the bones of lower limb joints such as the knee. However, details on the temporal response of this relationship to prolonged immobilization and its reversibility is limited. Forty rats had one knee immobilized at 45° of flexion for 2, 4, 8, or 16 weeks and subsequently remobilized for 0 or 8 weeks. The contralateral knees were used as controls. Histomorphometric measures of trabecular bone and marrow adipose tissue (MAT) areas were conducted in the epiphysis of the proximal tibia. Knee immobilization for 4, 8, and 16 weeks significantly reduced trabecular bone area by -0.125, -0.139, and -0.161 mm2/mm2, respectively, with corresponding 95 % CIs of [-0.012, -0.239], [-0.006, -0.273], and [-0.101, -0.221]. MAT area significantly increased at 2 and 16 weeks by +0.008 and +0.027 mm2/mm2, respectively, with 95 % CIs of [0.014, 0.002] and [0.039, 0.016]. Remobilization for 8 weeks restored trabecular bone area compared to the contralateral knee and the magnitude of change was significantly greater for 8 and 16 weeks of immobilization with effect sizes of 1.69 and 1.86, respectively. The difference in MAT area between immobilized and contralateral knees were eliminated with remobilization. These results characterize the temporal response of trabecular bone and MAT in the epiphysis of the proximal tibia to joint immobilization and remobilization.
Collapse
|
26
|
Reynolds R, Garner A, Norton J. Sound and Vibration as Research Variables in Terrestrial Vertebrate Models. ILAR J 2020; 60:159-174. [PMID: 32602530 DOI: 10.1093/ilar/ilaa004] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/28/2019] [Revised: 02/07/2020] [Accepted: 02/11/2020] [Indexed: 12/31/2022] Open
Abstract
Sound and vibration have been shown to alter animal behavior and induce physiological changes as well as to cause effects at the cellular and molecular level. For these reasons, both environmental factors have a considerable potential to alter research outcomes when the outcome of the study is dependent on the animal existing in a normal or predictable biological state. Determining the specific levels of sound or vibration that will alter research is complex, as species will respond to different frequencies and have varying frequencies where they are most sensitive. In consideration of the potential of these factors to alter research, a thorough review of the literature and the conditions that likely exist in the research facility should occur specific to each research study. This review will summarize the fundamental physical properties of sound and vibration in relation to deriving maximal level standards, consider the sources of exposure, review the effects on animals, and discuss means by which the adverse effects of these factors can be mitigated.
Collapse
Affiliation(s)
- Randall Reynolds
- Duke University School of Medicine, Department of Pathology and Division of Laboratory Animal Resources, Durham, NC
| | - Angela Garner
- Duke University School of Medicine, Division of Laboratory Animal Resources, Durham, NC
| | - John Norton
- Duke University School of Medicine, Pathology and Division of Laboratory Animal Resources
| |
Collapse
|
27
|
Low Intensity Vibrations Augment Mesenchymal Stem Cell Proliferation and Differentiation Capacity during in vitro Expansion. Sci Rep 2020; 10:9369. [PMID: 32523117 PMCID: PMC7286897 DOI: 10.1038/s41598-020-66055-0] [Citation(s) in RCA: 20] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/27/2019] [Accepted: 05/13/2020] [Indexed: 01/09/2023] Open
Abstract
A primary component of exercise, mechanical signals, when applied in the form of low intensity vibration (LIV), increases mesenchymal stem cell (MSC) osteogenesis and proliferation. While it is generally accepted that exercise effectively combats the deleterious effects of aging in the musculoskeletal system, how long-term exercise affects stem cell aging, which is typified by reduced proliferative and differentiative capacity, is not well explored. As a first step in understanding the effect of long-term application of mechanical signals on stem cell function, we investigated the effect of LIV during in vitro expansion of MSCs. Primary MSCs were subjected to either a control or to a twice-daily LIV regimen for up to sixty cell passages (P60) under in vitro cell expansion conditions. LIV effects were assessed at both early passage (EP) and late passage (LP). At the end of the experiment, P60 cultures exposed to LIV maintained a 28% increase of cell doubling and a 39% reduction in senescence-associated β-galactosidase activity (p < 0.01) but no changes in telomere lengths and p16INK4a levels were observed. Prolonged culture-associated decreases in osteogenic and adipogenic capacity were partially protected by LIV in both EP and LP groups (p < 0.05). Mass spectroscopy of late passage MSC indicated a synergistic decrease of actin and microtubule cytoskeleton-associated proteins in both control and LIV groups while LIV induced a recovery of proteins associated with oxidative reductase activity. In summary, our findings show that the application of long-term mechanical challenge (+LIV) during in vitro expansion of MSCs for sixty passages significantly alters MSC proliferation, differentiation and structure. This suggests LIV as a potential tool to investigate the role of physical activity during aging.
Collapse
|
28
|
Yoon C, Chang MJ, Chang CB, Chai JW, Jeong H, Song MK, Shin JH, Kang SB. Bone Mineral Density Around the Knee Joint: Correlation With Central Bone Mineral Density and Associated Factors. J Clin Densitom 2020; 23:82-91. [PMID: 30120026 DOI: 10.1016/j.jocd.2018.07.005] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 02/19/2018] [Revised: 07/04/2018] [Accepted: 07/10/2018] [Indexed: 11/21/2022]
Abstract
INTRODUCTION The aims of this study were to (1) assess the bone mineral density (BMD) around the knee joint, (2) determine the correlation between central and knee BMDs, and (3) investigate the factors associated with BMD around the knee joint in patients with knee osteoarthritis (OA). METHODOLOGY This cross-sectional study included 122 patients who underwent total knee arthroplasty. Central and knee dual-energy X-ray absorptiometry was performed preoperatively. BMD at 6 regions of interest (ROIs) around the knee joint were measured, and their correlations with central BMD were determined using Spearman's correlation analysis. Lower limb alignment, severity of OA, body mass index (BMI), preoperative functional and pain scores were assessed to elucidate the factors associated with knee BMD using linear regression analysis. RESULTS Around the knee joint, BMD was the lowest at the distal femoral metaphysis and lateral tibial condyle. Knee BMD was significantly correlated with central BMD. However, the correlation coefficients varied by the ROI. Additionally, multivariate analysis revealed different associations with respect to the regions around the knee joint. Varus alignment of the lower limb was associated with increased BMD of the medial condyles and decreased BMD of lateral condyles. High grade OA was a protective factor; it was associated with increased BMD at the lateral condyles of the femur and tibia. Higher BMI was an independent protective factor in all ROIs around the knee joint except the lateral femoral condyles. Lower functional level was not associated with decreased BMD, whereas a higher pain score was significantly associated with lower BMD at the proximal tibial metaphysis. CONCLUSIONS Knee BMD was significantly correlated with central BMD. However, the correlations varied with the regions around the knee joint probably due to their independent association with the alignment of the lower limb, severity of OA, BMI, and preoperative pain level.
Collapse
Affiliation(s)
- Chan Yoon
- Department of Orthopaedic Surgery, Seoul National University College of Medicine, SMG-SNU Boramae Medical Center, Seoul, South Korea
| | - Moon Jong Chang
- Department of Orthopaedic Surgery, Seoul National University College of Medicine, SMG-SNU Boramae Medical Center, Seoul, South Korea
| | - Chong Bum Chang
- Department of Orthopaedic Surgery, Seoul National University College of Medicine, SMG-SNU Boramae Medical Center, Seoul, South Korea;.
| | - Jee Won Chai
- Department of Radiology, Seoul National University College of Medicine, SMG-SNU Boramae Medical Center, Seoul, South Korea
| | - Hyunseok Jeong
- Department of Orthopaedic Surgery, Seoul National University College of Medicine, SMG-SNU Boramae Medical Center, Seoul, South Korea
| | - Min Kyu Song
- Department of Orthopaedic Surgery, Seoul National University College of Medicine, SMG-SNU Boramae Medical Center, Seoul, South Korea
| | - Jae Hoon Shin
- Department of Orthopaedic Surgery, Seoul National University College of Medicine, SMG-SNU Boramae Medical Center, Seoul, South Korea
| | - Seung-Baik Kang
- Department of Orthopaedic Surgery, Seoul National University College of Medicine, SMG-SNU Boramae Medical Center, Seoul, South Korea
| |
Collapse
|
29
|
Huseman CJ, Sigler DH, Welsh TH, Suva LJ, Vogelsang MM, Dominguez BJ, Huggins S, Paulk C. Skeletal response to whole body vibration and dietary calcium and phosphorus in growing pigs. J Anim Sci 2019; 97:3369-3378. [PMID: 31265734 DOI: 10.1093/jas/skz189] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/27/2019] [Accepted: 05/21/2019] [Indexed: 11/13/2022] Open
Abstract
The quality and strength of the skeleton is regulated by mechanical loading and adequate mineral intake of calcium (Ca) and phosphorus (P). Whole body vibration (WBV) has been shown to elicit adaptive responses in the skeleton, such as increased bone mass and strength. This experiment was designed to determine the effects of WBV and dietary Ca and P on bone microarchitecture and turnover. A total of 26 growing pigs were utilized in a 60-d experiment. Pigs were randomly assigned within group to a 2 × 2 factorial design with dietary Ca and P concentration (low and adequate) as well as WBV. The adequate diet was formulated to meet all nutritional needs according to the NRC recommendations for growing pigs. Low Ca, P diets had 0.16% lower Ca and 0.13% lower P than the adequate diet. Pigs receiving WBV were vibrated 30 min/d, 3 d/wk at a magnitude of 1 to 2 mm and a frequency of 50 Hz. On days 0, 30, and 60, digital radiographs were taken to determine bone mineral content by radiographic bone aluminum equivalency (RBAE) and serum was collected to measure biochemical markers of bone formation (osteocalcin, OC) and bone resorption (carboxy-terminal collagen crosslinks, CTX-I). At day 60, pigs were euthanized and the left third metacarpal bone was excised for detailed analysis by microcomputed tomography (microCT) to measure trabecular microarchitecture and cortical bone geometry. Maximum RBAE values for the medial or lateral cortices were not affected (P > 0.05) by WBV. Pigs fed adequate Ca and P tended (P = 0.10) to have increased RBAE max values for the medial and lateral cortices. WBV pigs had significantly decreased serum CTX-1 concentrations (P = 0.044), whereas animals fed a low Ca and P diet had increased (P < 0.05) OC concentrations. In bone, WBV pigs showed a significantly lower trabecular number (P = 0.002) and increased trabecular separation (P = 0.003), whereas cortical bone parameters were not significantly altered by WBV or diet (P > 0.05). In summary, this study confirmed the normal physiological responses of the skeleton to a low Ca, P diet. Interestingly, although the WBV protocol utilized in this study did not elicit any significant osteogenic response, decreases in CTX-1 in response to WBV may have been an early local adaptive bone response. We interpret these data to suggest that the frequency and amplitude of WBV was likely sufficient to elicit a bone remodeling response, but the duration of the study may not have captured the full extent of an entire bone remodeling cycle.
Collapse
Affiliation(s)
| | | | | | | | | | | | | | - Chad Paulk
- Texas A&M University, College Station, TX.,Kansas State University, Manhattan, KS
| |
Collapse
|
30
|
Kannan S, Fassul S, Singh AK, Arora N, Malhotra A, Saini N. Effectiveness and importance of powered tooth brushes in tooth movement. J Family Med Prim Care 2019; 8:2478-2483. [PMID: 31463280 PMCID: PMC6691431 DOI: 10.4103/jfmpc.jfmpc_352_19] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/21/2022] Open
Abstract
Introduction: Effectiveness of vibratory stimulus from a commonly available battery-powered tooth brush in accelerating orthodontic tooth movement was tested by a randomized controlled split-mouth study. Materials and Methods: Twenty-three subjects with bimaxillary protrusion, requiring extraction of all first premolars and requiring maximum anchorage, were chosen. After initial leveling and aligning, miniscrews were placed between the first molar and the second premolar in the maxillary right and left quadrants and loaded with 150-g nickel–titanium closed-coil springs for individual canine retraction. Additional 5 min of vibratory stimulus thrice daily was applied on the experimental side. The mean treatment duration was 3 months. Results: There was no significant difference of means of the canine distal movement between the experimental and the control sides (P = 0.70). Conclusion: Application of vibratory stimulus with powered tooth brush during canine retraction was not seen to have an acceleratory effect on orthodontic tooth movement.
Collapse
Affiliation(s)
- Sridhar Kannan
- Department of Orthodontics, Manav Rachna Dental College, Faridabad, Haryana, India
| | - Sajna Fassul
- Department of Orthodontics, Manav Rachna Dental College, Faridabad, Haryana, India
| | - Ashish Kumar Singh
- Department of Orthodontics, Manav Rachna Dental College, Faridabad, Haryana, India
| | - Nitin Arora
- Department of Orthodontics, Manav Rachna Dental College, Faridabad, Haryana, India
| | - Abhita Malhotra
- Department of Orthodontics, Manav Rachna Dental College, Faridabad, Haryana, India
| | - Neeraj Saini
- Department of Orthodontics, Manav Rachna Dental College, Faridabad, Haryana, India
| |
Collapse
|
31
|
Pagnotti GM, Styner M, Uzer G, Patel VS, Wright LE, Ness KK, Guise TA, Rubin J, Rubin CT. Combating osteoporosis and obesity with exercise: leveraging cell mechanosensitivity. Nat Rev Endocrinol 2019; 15:339-355. [PMID: 30814687 PMCID: PMC6520125 DOI: 10.1038/s41574-019-0170-1] [Citation(s) in RCA: 151] [Impact Index Per Article: 25.2] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 12/13/2022]
Abstract
Osteoporosis, a condition of skeletal decline that undermines quality of life, is treated with pharmacological interventions that are associated with poor adherence and adverse effects. Complicating efforts to improve clinical outcomes, the incidence of obesity is increasing, predisposing the population to a range of musculoskeletal complications and metabolic disorders. Pharmacological management of obesity has yet to deliver notable reductions in weight and debilitating complications are rarely avoided. By contrast, exercise shows promise as a non-invasive and non-pharmacological method of regulating both osteoporosis and obesity. The principal components of exercise - mechanical signals - promote bone and muscle anabolism while limiting formation and expansion of fat mass. Mechanical regulation of bone and marrow fat might be achieved by regulating functions of differentiated cells in the skeletal tissue while biasing lineage selection of their common progenitors - mesenchymal stem cells. An inverse relationship between adipocyte versus osteoblast fate selection from stem cells is implicated in clinical conditions such as childhood obesity and increased marrow adiposity in type 2 diabetes mellitus, as well as contributing to skeletal frailty. Understanding how exercise-induced mechanical signals can be used to improve bone quality while decreasing fat mass and metabolic dysfunction should lead to new strategies to treat chronic diseases such as osteoporosis and obesity.
Collapse
Affiliation(s)
- Gabriel M Pagnotti
- School of Medicine, Division of Endocrinology, Indiana University, Indianapolis, IN, USA
| | - Maya Styner
- Department of Medicine, Division of Endocrinology and Metabolism, University of North Carolina, Chapel Hill, NC, USA
| | - Gunes Uzer
- College of Mechanical and Biomedical Engineering, Boise State University, Boise, ID, USA
| | - Vihitaben S Patel
- Department of Biomedical Engineering, Stony Brook University, Stony Brook, NY, USA
| | - Laura E Wright
- School of Medicine, Division of Endocrinology, Indiana University, Indianapolis, IN, USA
| | - Kirsten K Ness
- Department of Epidemiology and Cancer Control, St. Jude Children's Research Hospital, Memphis, TN, USA
| | - Theresa A Guise
- School of Medicine, Division of Endocrinology, Indiana University, Indianapolis, IN, USA
| | - Janet Rubin
- Department of Medicine, Division of Endocrinology and Metabolism, University of North Carolina, Chapel Hill, NC, USA
| | - Clinton T Rubin
- Department of Biomedical Engineering, Stony Brook University, Stony Brook, NY, USA.
| |
Collapse
|
32
|
Sakamoto M, Fukunaga T, Sasaki K, Seiryu M, Yoshizawa M, Takeshita N, Takano-Yamamoto T. Vibration enhances osteoclastogenesis by inducing RANKL expression via NF-κB signaling in osteocytes. Bone 2019; 123:56-66. [PMID: 30902792 DOI: 10.1016/j.bone.2019.03.024] [Citation(s) in RCA: 23] [Impact Index Per Article: 3.8] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 11/30/2018] [Revised: 02/14/2019] [Accepted: 03/18/2019] [Indexed: 12/27/2022]
Abstract
To shorten the duration of orthodontic treatment it is important not only to reduce risks such as dental caries, periodontal disease, and root resorption, but also to decrease pain and discomfort caused by a fixed appliance. Several studies have investigated the effect of vibration applied to fixed appliances to accelerate tooth movement. Although it was reported that vibration accelerates orthodontic tooth movement by enhancing alveolar bone resorption, the underlying cellular and molecular mechanisms remain unclear. In this study, we investigated the effects of vibration on osteoclastogenesis in vitro and in vivo. Vibration applied to pre-osteoclast cell line RAW264.7 cells enhanced cell proliferation but did not affect their differentiation into osteoclasts. Osteocytes in bone are known to be mechanosensitive and to act as receptor activator of nuclear factor kappa B (NF-κB) ligand (RANKL). Therefore, in the present study, vibration was applied to cells from the osteocyte-like cell line MLO-Y4. In MLO-Y4 cells, vibration induced phosphorylation of the inhibitor of NF-κB (IκB) and caused nuclear localization of NF-κB p65. Additionally, vibration increased RANKL mRNA expression, but did not affect osteoprotegerin (OPG) mRNA expression in MLO-Y4 cells, thus resulting in an increased RANKL/OPG ratio. Consistent with these findings, vibration applied during experimental tooth movement increased NF-κB activation and RANKL expression in osteocytes on the compression side of alveolar bone in vivo, whereas vibration had no such effects on the tension side. Furthermore, in a co-culture of MLO-Y4 cells and RAW264.7 cells, vibration applied to MLO-Y4 cells enhanced osteoclastogenesis. These findings suggest that vibration could accelerate orthodontic tooth movement by enhancing osteoclastogenesis through increasing the number of pre-osteoclasts and up-regulating RANKL expression in osteocytes on the compression side of alveolar bone via NF-κB activation.
Collapse
Affiliation(s)
- Mayuri Sakamoto
- Division of Orthodontics and Dentofacial Orthopedics, Tohoku University Graduate School of Dentistry, 4-1, Seiryo-machi, Aoba-ku, Sendai, Miyagi 980-8575, Japan.
| | - Tomohiro Fukunaga
- Division of Orthodontics and Dentofacial Orthopedics, Tohoku University Graduate School of Dentistry, 4-1, Seiryo-machi, Aoba-ku, Sendai, Miyagi 980-8575, Japan.
| | - Kiyo Sasaki
- Division of Orthodontics and Dentofacial Orthopedics, Tohoku University Graduate School of Dentistry, 4-1, Seiryo-machi, Aoba-ku, Sendai, Miyagi 980-8575, Japan.
| | - Masahiro Seiryu
- Division of Orthodontics and Dentofacial Orthopedics, Tohoku University Graduate School of Dentistry, 4-1, Seiryo-machi, Aoba-ku, Sendai, Miyagi 980-8575, Japan.
| | - Mitsuhiro Yoshizawa
- Division of Orthodontics and Dentofacial Orthopedics, Tohoku University Graduate School of Dentistry, 4-1, Seiryo-machi, Aoba-ku, Sendai, Miyagi 980-8575, Japan.
| | - Nobuo Takeshita
- Division of Orthodontics and Dentofacial Orthopedics, Tohoku University Graduate School of Dentistry, 4-1, Seiryo-machi, Aoba-ku, Sendai, Miyagi 980-8575, Japan.
| | - Teruko Takano-Yamamoto
- Division of Orthodontics and Dentofacial Orthopedics, Tohoku University Graduate School of Dentistry, 4-1, Seiryo-machi, Aoba-ku, Sendai, Miyagi 980-8575, Japan; Department of Biomaterials and Bioengineering, Faculty of Dental Medicine, Hokkaido University, Kita 13, Nishi 7, Kita-ku, Sapporo, Hokkaido 060-8586, Japan.
| |
Collapse
|
33
|
Touchstone H, Bryd R, Loisate S, Thompson M, Kim S, Puranam K, Senthilnathan AN, Pu X, Beard R, Rubin J, Alwood J, Oxford JT, Uzer G. Recovery of stem cell proliferation by low intensity vibration under simulated microgravity requires LINC complex. NPJ Microgravity 2019; 5:11. [PMID: 31123701 PMCID: PMC6520402 DOI: 10.1038/s41526-019-0072-5] [Citation(s) in RCA: 32] [Impact Index Per Article: 5.3] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/18/2018] [Accepted: 03/20/2019] [Indexed: 12/20/2022] Open
Abstract
Mesenchymal stem cells (MSC) rely on their ability to integrate physical and spatial signals at load bearing sites to replace and renew musculoskeletal tissues. Designed to mimic unloading experienced during spaceflight, preclinical unloading and simulated microgravity models show that alteration of gravitational loading limits proliferative activity of stem cells. Emerging evidence indicates that this loss of proliferation may be linked to loss of cellular cytoskeleton and contractility. Low intensity vibration (LIV) is an exercise mimetic that promotes proliferation and differentiation of MSCs by enhancing cell structure. Here, we asked whether application of LIV could restore the reduced proliferative capacity seen in MSCs that are subjected to simulated microgravity. We found that simulated microgravity (sMG) decreased cell proliferation and simultaneously compromised cell structure. These changes included increased nuclear height, disorganized apical F-actin structure, reduced expression, and protein levels of nuclear lamina elements LaminA/C LaminB1 as well as linker of nucleoskeleton and cytoskeleton (LINC) complex elements Sun-2 and Nesprin-2. Application of LIV restored cell proliferation and nuclear proteins LaminA/C and Sun-2. An intact LINC function was required for LIV effect; disabling LINC functionality via co-depletion of Sun-1, and Sun-2 prevented rescue of cell proliferation by LIV. Our findings show that sMG alters nuclear structure and leads to decreased cell proliferation, but does not diminish LINC complex mediated mechanosensitivity, suggesting LIV as a potential candidate to combat sMG-induced proliferation loss.
Collapse
Affiliation(s)
- H. Touchstone
- Department of Mechanical and Biomedical Engineering, Boise State University, Boise, ID 83725 USA
| | - R. Bryd
- Department of Mechanical and Biomedical Engineering, Boise State University, Boise, ID 83725 USA
| | - S. Loisate
- Department of Mechanical and Biomedical Engineering, Boise State University, Boise, ID 83725 USA
| | - M. Thompson
- Department of Mechanical and Biomedical Engineering, Boise State University, Boise, ID 83725 USA
| | - S. Kim
- Department of Medicine, University of North Carolina Chapel Hill, Chapel Hill, NC 27599 USA
| | - K. Puranam
- Department of Medicine, University of North Carolina Chapel Hill, Chapel Hill, NC 27599 USA
| | - A. N. Senthilnathan
- Department of Medicine, University of North Carolina Chapel Hill, Chapel Hill, NC 27599 USA
| | - X. Pu
- Biomolecular Research Center, Boise State University, Boise, ID 83725 USA
| | - R. Beard
- Biomolecular Research Center, Boise State University, Boise, ID 83725 USA
| | - J. Rubin
- Department of Medicine, University of North Carolina Chapel Hill, Chapel Hill, NC 27599 USA
| | - J. Alwood
- Space Biosciences Division, NASA-Ames Research Center, Mountain View, CA 94035 USA
| | - J. T. Oxford
- Biomolecular Research Center, Boise State University, Boise, ID 83725 USA
| | - G. Uzer
- Department of Mechanical and Biomedical Engineering, Boise State University, Boise, ID 83725 USA
| |
Collapse
|
34
|
Caryn RC, Dickey JP. Transmission of Acceleration From a Synchronous Vibration Exercise Platform to the Head During Dynamic Squats. Dose Response 2019; 17:1559325819827467. [PMID: 30833873 PMCID: PMC6393836 DOI: 10.1177/1559325819827467] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/18/2018] [Revised: 12/28/2018] [Accepted: 01/08/2019] [Indexed: 11/28/2022] Open
Abstract
Many research studies have evaluated the effects of whole-body vibration exercise on muscular strength, standing balance, and bone density, but relatively few reports have evaluated safety issues for vibration exercises. Knee flexion reduces acceleration transmission to the head during static exercise. However, few studies have evaluated dynamic exercises. The purpose of this investigation was to evaluate the transmission of acceleration to the head during dynamic squats. Twelve participants performed dynamic squats (0°-40° of knee flexion) on a synchronous vertical whole-body vibration platform. Platform frequencies from 20 to 50 Hz were tested at a peak-to-peak nominal displacement setting of 1 mm. Transmissibilities from the platform to head varied depending on platform frequency and knee flexion angle. We observed amplification during 20 and 25 Hz platform vibration when knee flexion was <20°. Vibration from exercise platforms can be amplified as it is transmitted through the body to the head during dynamic squats. Similarly, this vibration energy contributes to observed injuries such as retinal detachment. It is recommended that knee flexion angles of at least 20° and vibration frequencies above 30 Hz are used when performing dynamic squat exercises with whole-body vibration.
Collapse
Affiliation(s)
- Robert C Caryn
- School of Kinesiology, Western University, London, Ontario, Canada
| | - James P Dickey
- School of Kinesiology, Western University, London, Ontario, Canada
| |
Collapse
|
35
|
Javaheri B, Bravenboer N, Bakker AD, van der Veen A, de Souza RL, Saxon L, Pitsillides AA. In Vivo Models of Mechanical Loading. Methods Mol Biol 2019; 1914:369-390. [PMID: 30729478 DOI: 10.1007/978-1-4939-8997-3_22] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 06/09/2023]
Abstract
The skeleton fulfils its mechanical functions through structural organization and material properties of individual bones. It is stated that both cortical and trabecular morphology and mass can be (re)modelled in response to changes in mechanical strains engendered by load-bearing. To address this, animal models that enable the application of specific loads to individual bones have been developed. These are useful in defining how loading modulates (re)modeling and allow examination of the mechanisms that coordinate these events. This chapter describes how to apply mechanical loading to murine bones through points of articulation, which allows changes in endosteal, periosteal as well as trabecular bone to be revealed at multiple hierarchies, by a host of methodologies, including double fluorochrome labeling and computed tomography.
Collapse
Affiliation(s)
- Behzad Javaheri
- Skeletal Biology Group, Comparative Biomedical Sciences, The Royal Veterinary College, London, UK
| | - Nathalie Bravenboer
- Department Clinical Chemistry, VU University Medical Center, Amsterdam, The Netherlands
- Center for Bone Quality and Department of Internal Medicine, Division Endocrinology, Leiden University Medical Center, Leiden, The Netherlands
| | - Astrid D Bakker
- Department of Oral Cell Biology, Academic Centre for Dentistry Amsterdam, Amsterdam, The Netherlands
| | - Albert van der Veen
- Department of Physics and Medical Technology, VU University Medical Center, Amsterdam, The Netherlands
| | | | | | - Andrew A Pitsillides
- Skeletal Biology Group, Comparative Biomedical Sciences, The Royal Veterinary College, London, UK.
| |
Collapse
|
36
|
Yashmin S, Pandey A, Sabir SA. Vibrations in orthodontics: Is it the future? INTERNATIONAL JOURNAL OF ORTHODONTIC REHABILITATION 2019. [DOI: 10.4103/ijor.ijor_24_19] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/04/2022]
|
37
|
Saers JPP, Ryan TM, Stock JT. Trabecular bone functional adaptation and sexual dimorphism in the human foot. AMERICAN JOURNAL OF PHYSICAL ANTHROPOLOGY 2018; 168:154-169. [DOI: 10.1002/ajpa.23732] [Citation(s) in RCA: 16] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Received: 05/28/2018] [Revised: 09/25/2018] [Accepted: 09/26/2018] [Indexed: 11/09/2022]
Affiliation(s)
- Jaap P. P. Saers
- Department of Archaeology, University of Cambridge McDonald Institute for Archaeological Research Cambridge United Kingdom
| | - Timothy M. Ryan
- Department of Anthropology Pennsylvania State University State College Pennsylvania
| | - Jay T. Stock
- Department of Archaeology, University of Cambridge McDonald Institute for Archaeological Research Cambridge United Kingdom
- Department of Anthropology University of Western Ontario London Ontario Canada
- Department of Archaeology Max Planck Institute for the Science of Human History Jena Germany
| |
Collapse
|
38
|
Reynolds RP, Li Y, Garner A, Norton JN. Vibration in mice: A review of comparative effects and use in translational research. Animal Model Exp Med 2018; 1:116-124. [PMID: 30891556 PMCID: PMC6388090 DOI: 10.1002/ame2.12024] [Citation(s) in RCA: 18] [Impact Index Per Article: 2.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/09/2018] [Accepted: 06/11/2018] [Indexed: 11/10/2022] Open
Abstract
Sound pressure waves surround individuals in everyday life and are perceived by animals and humans primarily through sound or vibration. When sound pressure waves traverse through a solid medium, vibration will result. Vibration has long been considered an unwanted variable in animal research and may confound scientific endeavors using animals. Understanding the characteristics of vibration is required to determine whether effects in animals are likely to be therapeutic or result in adverse biological effects. The eighth edition of the "Guide for the Care and Use of Laboratory Animals" highlights the importance of considering vibration and its effects on animals in the research setting, but knowledge of the level of vibration for eliciting these effects was unknown. The literature provides information regarding therapeutic use of vibration in humans, but the range of conditions to be of therapeutic benefit is varied and without clarity. Understanding the characteristics of vibration (eg, frequency and magnitude) necessary to cause various effects will ultimately assist in the evaluation of this environmental factor and its role on a number of potential therapeutic regimens for use in humans. This paper will review the principles of vibration, sources within a research setting, comparative physiological effects in various species, and the relative potential use of vibration in the mouse as a translational research model.
Collapse
Affiliation(s)
- Randall P. Reynolds
- Division of Laboratory Animal ResourcesDuke University Medical CenterDurhamNCUSA
| | - Yao Li
- Department of Laboratory Animal ScienceSchool of MedicineShanghai Jiao Tong UniversityShanghaiChina
| | - Angela Garner
- Division of Laboratory Animal ResourcesDuke University Medical CenterDurhamNCUSA
| | - John N. Norton
- Division of Laboratory Animal ResourcesDuke University Medical CenterDurhamNCUSA
- Department of PathologyDuke University Medical CenterDurhamNCUSA
| |
Collapse
|
39
|
A systematic review of the exercise effect on bone health: the importance of assessing mechanical loading in perimenopausal and postmenopausal women. Menopause 2018; 24:1208-1216. [PMID: 28538603 DOI: 10.1097/gme.0000000000000872] [Citation(s) in RCA: 29] [Impact Index Per Article: 4.1] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/19/2022]
Abstract
OBJECTIVE The aims of this systematic review were to determine the general effects of exercise on areal bone mineral density (BMD) in perimenopausal and postmenopausal women, and to provide information on the most suitable bone-loading exercise regimens that may improve bone health in this population group. METHODS A computerized, systematic literature search was performed in the electronic databases PubMed, Web of Science, CINAHL, SPORTDiscus, and The Cochrane Library, from January 2005 to November 2015, to identify all randomized controlled trials related to exercise in perimenopausal and postmenopausal women. The initial search identified 915 studies, with a final yield of 10 studies. Only randomized controlled trials that examined the effects of exercise programs longer than 24 weeks in women aged 35 to 70 years were included. The 10 studies quantified at least BMD and described training variables adequately (training period, frequency, volume, intensity). RESULTS Ten studies with moderate quality evidence (6.4 ± 1.8 points, range 4-9) were included. Significant changes in lumbar and femoral neck BMD were found mainly with high-impact exercise and whole body vibration interventions. CONCLUSIONS While training effects must be interpreted with caution because of the heterogeneity of the protocols and exercises performed, this systematic review confirmed the effectiveness of impact exercises combined with other forms of training (vibration or strength training) to preserve BMD in perimenopausal and postmenopausal women. Despite the results possibly not representing a general dose-response relationship, we highlight the importance of quantifying loading intensity and frequency by means of accelerometry as these parameters are determinants for bone adaptation.
Collapse
|
40
|
Vibration loading promotes osteogenic differentiation of bone marrow-derived mesenchymal stem cells via p38 MAPK signaling pathway. J Biomech 2018; 71:67-75. [PMID: 29503016 DOI: 10.1016/j.jbiomech.2018.01.039] [Citation(s) in RCA: 25] [Impact Index Per Article: 3.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/21/2017] [Revised: 12/19/2017] [Accepted: 01/28/2018] [Indexed: 12/27/2022]
Abstract
Low magnitude high frequency vibration (LMHFV) exhibits effectively anabolic effects on the bone tissue, and can promote osteogenic differentiation of mesenchymal stem cells (MSCs) in vitro. The role of p38 MAPK signaling in LMHFV-induced osteogenesis remains unclear. In this current study, LMHFV loading was applied to BMSCs in vitro, and cell proliferation, alkaline phosphatase (ALP), matrix mineralization, as well as osteogenic genes expression were assayed. The mechanism of mechanical signal transduction was analysed using PCR array, qRT-PCR and Western blot. LMHFV increased cell proliferation in the growth medium, while inhibited proliferation in the osteogenic medium. ALP activity, matrix mineralization and osteogenic genes expression of Runx2, Col-I, ALP, OPN and OC were increased by LMHFV. p38 and MKK6 genes expression, and p38 phosphorylation were promoted in LMHFV-induced osteogenesis. Inhibition of p38 MAPK with SB203580 and targeted p38 siRNA blunted the increased ALP activity and osteogenic genes expression by LMHFV. These findings suggest that LMHFV promotes osteogenic differentiation of BMSCs, and p38 MAPK signaling shows an important function in LMHFV-induced osteogenesis.
Collapse
|
41
|
Saggini R, Ancona E, Carmignano SM, Supplizi M, Barassi G, Bellomo RG. Effect of combined treatment with focused mechano-acoustic vibration and pharmacological therapy on bone mineral density and muscle strength in post-menopausal women. ACTA ACUST UNITED AC 2017; 14:305-311. [PMID: 29354158 DOI: 10.11138/ccmbm/2017.14.3.305] [Citation(s) in RCA: 10] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/17/2022]
Abstract
Introduction Osteoporosis is a systemic disease of the skeleton characterized by a reduction in bone mass and alterations in microarchitecture accompanied by increase in fracture risk, with a relevant decline in quality of life and important social, economic, and health implications, representing one of the most common causes of disability and a major financial item of health cost in many Countries. The best therapy for osteoporosis is prevention, consisting in measures to avoid or slow the onset of the disease. Treatment includes measures aimed at osteoporotic individuals, with or without previous fractures and a high risk of a first or additional fracture. Method We enrolled thirty post-menopausal osteoporotic women, allocated in the first group underwent a 6-month personalized drug therapy and focused mechanoacoustic vibration (2 sessions per week, each lasting 15 minutes); women allocated in the second group underwent only 6-month personalized drug therapy. Patients were evaluated performing dual-energy X-ray absorptiometry (DXA) and isokinetic machine evaluation, and administration of Tinetti scale and ECOS-16 questionnaire. Result Show improvement of bone mineral density (BMD) and T-score at the lumbar spine and femoral neck, handgrip strength and isokinetic strength of the knee estensors, balance and gait, and quality of life. Conclusion Hence, the combined treatment with focused mechano-acoustic vibration and pharmacological therapy has a beneficial effect on BMD and T-score as well as on the muscle strength and quality of life of osteoporotic subjects.
Collapse
Affiliation(s)
- Raoul Saggini
- Full Professor, Physical and Rehabilitation Medicine, Department of Medical Oral and Biotechnological Sciences, Director of the School of Specialty in Physical and Rehabilitation Medicine, "Gabriele d'Annunzio" University, Chieti-Pescara, Italy; National Coordinator of Schools of Specialty in Physical and Rehabilitation Medicine
| | - Emilio Ancona
- School of Specialty in Physical and Rehabilitation Medicine, "Gabriele d'Annunzio" University of Chieti-Pescara, Italy
| | - Simona Maria Carmignano
- School of Specialty in Physical and Rehabilitation Medicine, "Gabriele d'Annunzio" University of Chieti-Pescara, Italy
| | - Marco Supplizi
- Section of Physical and Rehabilitation Medicine, "Gabriele d'Annunzio" University of Chieti-Pescara, Italy
| | - Giovanni Barassi
- Chair of Physical and Rehabilitation Medicine, "Gabriele d'Annunzio" University of Chieti-Pescara, Italy
| | - Rosa Grazia Bellomo
- Associated Professor, Physical and Rehabilitation Medicine, Department of Medicine and Sciences of Aging, "Gabriele d'Annunzio" University of Chieti-Pescara, Italy
| |
Collapse
|
42
|
Jing D, Xiao J, Li X, Li Y, Zhao Z. The effectiveness of vibrational stimulus to accelerate orthodontic tooth movement: a systematic review. BMC Oral Health 2017; 17:143. [PMID: 29195495 PMCID: PMC5709826 DOI: 10.1186/s12903-017-0437-7] [Citation(s) in RCA: 27] [Impact Index Per Article: 3.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/08/2017] [Accepted: 11/21/2017] [Indexed: 02/05/2023] Open
Abstract
BACKGROUND In recent years, it has been a hot research topic to accelerate orthodontic tooth movement (OTM) through vibration. This review was therefore aimed to systematically evaluate the available evidences on the efficacy of vibrational stimulus to accelerate OTM. METHODS Randomized controlled trials and controlled clinical trials that evaluated the efficacy of vibration on OTM acceleration were searched through electronic and manual search. Two review authors independently conducted the study inclusion, quality assessment and data extraction. The quality of synthesized evidence was assessed according to GRADE system. RESULTS Eight clinical trials were included in this systematic review. Four studies found that vibration did not enhance the rate of OTM during alignment phase. Two studies revealed that the use of vibratory stimulation accelerated canine retraction. No deleterious effects including pain perceptions and root resorptions were reported. CONCLUSIONS Within the limitations of this review, weak evidence indicates that vibrational stimulus is effective for accelerating canine retraction but not for alignment. The effects of vibration on pain intensity and root resorption during orthodontic treatment are inconclusive. Future high-quality clinical trials are needed before warranting recommendations to clinical application.
Collapse
Affiliation(s)
- Dian Jing
- State Key Laboratory of Oral Diseases & National Clinical Research Center for Oral Diseases, Department of Orthodontics, West China Hospital of Stomatology, Sichuan University, Chengdu, China
| | - Jiani Xiao
- State Key Laboratory of Oral Diseases & National Clinical Research Center for Oral Diseases, Department of Orthodontics, West China Hospital of Stomatology, Sichuan University, Chengdu, China
| | - Xiaobing Li
- State Key Laboratory of Oral Diseases & National Clinical Research Center for Oral Diseases, Department of Pediatric Dentistry, West China Hospital of Stomatology, Sichuan University, Chengdu, China
| | - Yu Li
- State Key Laboratory of Oral Diseases & National Clinical Research Center for Oral Diseases, Department of Orthodontics, West China Hospital of Stomatology, Sichuan University, Chengdu, China
| | - Zhihe Zhao
- State Key Laboratory of Oral Diseases & National Clinical Research Center for Oral Diseases, Department of Orthodontics, West China Hospital of Stomatology, Sichuan University, Chengdu, China.
| |
Collapse
|
43
|
Barak MM, Sherratt E, Lieberman DE. Using principal trabecular orientation to differentiate joint loading orientation in the 3rd metacarpal heads of humans and chimpanzees. J Hum Evol 2017; 113:173-182. [DOI: 10.1016/j.jhevol.2017.08.018] [Citation(s) in RCA: 20] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/17/2016] [Revised: 08/04/2017] [Accepted: 08/30/2017] [Indexed: 11/24/2022]
|
44
|
Synergistic acceleration of experimental tooth movement by supplementary high-frequency vibration applied with a static force in rats. Sci Rep 2017; 7:13969. [PMID: 29070874 PMCID: PMC5656656 DOI: 10.1038/s41598-017-13541-7] [Citation(s) in RCA: 24] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/05/2017] [Accepted: 09/25/2017] [Indexed: 01/29/2023] Open
Abstract
Several recent prospective clinical trials have investigated the effect of supplementary vibration applied with fixed appliances in an attempt to accelerate tooth movement and shorten the duration of orthodontic treatment. Among them, some studies reported an increase in the rate of tooth movement, but others did not. This technique is still controversial, and the underlying cellular and molecular mechanisms remain unclear. In the present study, we developed a new vibration device for a tooth movement model in rats, and investigated the efficacy and safety of the device when used with fixed appliances. The most effective level of supplementary vibration to accelerate tooth movement stimulated by a continuous static force was 3 gf at 70 Hz for 3 minutes once a week. Furthermore, at this optimum-magnitude, high-frequency vibration could synergistically enhance osteoclastogenesis and osteoclast function via NF-κB activation, leading to alveolar bone resorption and finally, accelerated tooth movement, but only when a static force was continuously applied to the teeth. These findings contribute to a better understanding of the mechanism by which optimum-magnitude high-frequency vibration accelerates tooth movement, and may lead to novel approaches for the safe and effective treatment of malocclusion.
Collapse
|
45
|
Abstract
PURPOSE OF REVIEW This review assembles recent understanding of the profound loss of muscle and bone in spinal cord injury (SCI). It is important to try to understand these changes, and the context in which they occur, because of their impact on the wellbeing of SC-injured individuals, and the urgent need for viable preventative therapies. RECENT FINDINGS Recent research provides new understanding of the effects of age and systemic factors on the response of bone to loading, of relevance to attempts to provide load therapy for bone in SCI. The rapidly growing dataset describing the biochemical crosstalk between bone and muscle, and the cell and molecular biology of myokines signalling to bone and osteokines regulating muscle metabolism and mass, is reviewed. The ways in which this crosstalk may be altered in SCI is summarised. Therapeutic approaches to the catabolic changes in muscle and bone in SCI require a holistic understanding of their unique mechanical and biochemical context.
Collapse
Affiliation(s)
- Jillian M Clark
- Discipline of Orthopaedics and Trauma, The University of Adelaide, North Terrace, Adelaide, South Australia, 5000, Australia.
| | - David M Findlay
- Discipline of Orthopaedics and Trauma, The University of Adelaide, North Terrace, Adelaide, South Australia, 5000, Australia
| |
Collapse
|
46
|
Demontis GC, Germani MM, Caiani EG, Barravecchia I, Passino C, Angeloni D. Human Pathophysiological Adaptations to the Space Environment. Front Physiol 2017; 8:547. [PMID: 28824446 PMCID: PMC5539130 DOI: 10.3389/fphys.2017.00547] [Citation(s) in RCA: 197] [Impact Index Per Article: 24.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/18/2016] [Accepted: 07/14/2017] [Indexed: 12/29/2022] Open
Abstract
Space is an extreme environment for the human body, where during long-term missions microgravity and high radiation levels represent major threats to crew health. Intriguingly, space flight (SF) imposes on the body of highly selected, well-trained, and healthy individuals (astronauts and cosmonauts) pathophysiological adaptive changes akin to an accelerated aging process and to some diseases. Such effects, becoming manifest over a time span of weeks (i.e., cardiovascular deconditioning) to months (i.e., loss of bone density and muscle atrophy) of exposure to weightlessness, can be reduced through proper countermeasures during SF and in due time are mostly reversible after landing. Based on these considerations, it is increasingly accepted that SF might provide a mechanistic insight into certain pathophysiological processes, a concept of interest to pre-nosological medicine. In this article, we will review the main stress factors encountered in space and their impact on the human body and will also discuss the possible lessons learned with space exploration in reference to human health on Earth. In fact, this is a productive, cross-fertilized, endeavor in which studies performed on Earth yield countermeasures for protection of space crew health, and space research is translated into health measures for Earth-bound population.
Collapse
Affiliation(s)
| | - Marco M Germani
- MedLab, Institute of Life Sciences, Scuola Superiore Sant'AnnaPisa, Italy
| | - Enrico G Caiani
- Department of Electronics, Information and Biomedical Engineering, Politecnico di MilanoMilan, Italy
| | - Ivana Barravecchia
- Department of Pharmacy, University of PisaPisa, Italy.,MedLab, Institute of Life Sciences, Scuola Superiore Sant'AnnaPisa, Italy
| | - Claudio Passino
- MedLab, Institute of Life Sciences, Scuola Superiore Sant'AnnaPisa, Italy.,Fondazione Toscana G. MonasterioPisa, Italy
| | - Debora Angeloni
- MedLab, Institute of Life Sciences, Scuola Superiore Sant'AnnaPisa, Italy
| |
Collapse
|
47
|
Pham MH, Buser Z, Wang JC, Acosta FL. Low-magnitude mechanical signals and the spine: A review of current and future applications. J Clin Neurosci 2017; 40:18-23. [DOI: 10.1016/j.jocn.2016.12.017] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/09/2016] [Accepted: 12/27/2016] [Indexed: 01/17/2023]
|
48
|
Aguado E, Mabilleau G, Goyenvalle E, Chappard D. Hypodynamia Alters Bone Quality and Trabecular Microarchitecture. Calcif Tissue Int 2017; 100:332-340. [PMID: 28160025 DOI: 10.1007/s00223-017-0235-x] [Citation(s) in RCA: 15] [Impact Index Per Article: 1.9] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 09/06/2016] [Accepted: 01/07/2017] [Indexed: 01/06/2023]
Abstract
Disuse induces a rapid bone loss in humans and animals; hypodynamia/sedentarity is now recognized as a risk factor for osteoporosis. Hypodynamia also decreases bone mass but its effects are largely unknown and only few animal models have been described. Hypodynamic chicken is recognized as a suitable model of bone loss but the effects on the quality have not been fully explored. We have used ten chickens bred in a large enclosure (FREE group); ten others were confined in small cages with little space to move around (HYPO group). They were sacrificed at 53 days and femurs were evaluated by microcomputed tomography (microCT) and nanoindentation. Sections (4 µm thick) were analyzed by Fourier Transform InfraRed Microspectroscopy (FTIR) to see the effects on mineralization and collagen and quantitative backscattered electron imaging (qBEI) to image the mineral of the bone matrix. Trabecular bone volume and microarchitecture were significantly altered in the HYPO group. FTIR showed a significant reduction of the mineral-to-matrix ratio in the HYPO group associated with an increase in the carbonate content and an increase in crystallinity (calculated as the area ratio of subbands located at 1020 and 1030 cm-1) indicating a poor quality of the mineral. Collagen maturity (calculated as the area ratio of subbands located at 1660 and 1690 cm-1) was significantly reduced in the HYPO group. Reduced biomechanical properties were observed at the tissue level. Confined chicken represents a new model for the study of hypodynamia because bone changes are not created by a surgical lesion or a traumatic method. Animals have a reduced bone mass and present with an altered bone matrix quality which is less mineralized and whose collagen contains less crosslinks than in control chicken.
Collapse
Affiliation(s)
- Eric Aguado
- ONIRIS, Ecole Nationale Vétérinaire, route de Gachet, 44307, Nantes Cedex 3, France
- GEROM Groupe Etudes Remodelage Osseux et bioMatériaux, IRIS-IBS Institut de Biologie en Santé, CHU d'Angers, Université d'Angers, 49933, ANGERS Cedex, France
| | - Guillaume Mabilleau
- GEROM Groupe Etudes Remodelage Osseux et bioMatériaux, IRIS-IBS Institut de Biologie en Santé, CHU d'Angers, Université d'Angers, 49933, ANGERS Cedex, France
| | - Eric Goyenvalle
- ONIRIS, Ecole Nationale Vétérinaire, route de Gachet, 44307, Nantes Cedex 3, France
- GEROM Groupe Etudes Remodelage Osseux et bioMatériaux, IRIS-IBS Institut de Biologie en Santé, CHU d'Angers, Université d'Angers, 49933, ANGERS Cedex, France
| | - Daniel Chappard
- GEROM Groupe Etudes Remodelage Osseux et bioMatériaux, IRIS-IBS Institut de Biologie en Santé, CHU d'Angers, Université d'Angers, 49933, ANGERS Cedex, France.
| |
Collapse
|
49
|
Uchida R, Nakata K, Kawano F, Yonetani Y, Ogasawara I, Nakai N, Mae T, Matsuo T, Tachibana Y, Yokoi H, Yoshikawa H. Vibration acceleration promotes bone formation in rodent models. PLoS One 2017; 12:e0172614. [PMID: 28264058 PMCID: PMC5338772 DOI: 10.1371/journal.pone.0172614] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/12/2016] [Accepted: 02/06/2017] [Indexed: 11/30/2022] Open
Abstract
All living tissues and cells on Earth are subject to gravitational acceleration, but no reports have verified whether acceleration mode influences bone formation and healing. Therefore, this study was to compare the effects of two acceleration modes, vibration and constant (centrifugal) accelerations, on bone formation and healing in the trunk using BMP 2-induced ectopic bone formation (EBF) mouse model and a rib fracture healing (RFH) rat model. Additionally, we tried to verify the difference in mechanism of effect on bone formation by accelerations between these two models. Three groups (low- and high-magnitude vibration and control-VA groups) were evaluated in the vibration acceleration study, and two groups (centrifuge acceleration and control-CA groups) were used in the constant acceleration study. In each model, the intervention was applied for ten minutes per day from three days after surgery for eleven days (EBF model) or nine days (RFH model). All animals were sacrificed the day after the intervention ended. In the EBF model, ectopic bone was evaluated by macroscopic and histological observations, wet weight, radiography and microfocus computed tomography (micro-CT). In the RFH model, whole fracture-repaired ribs were excised with removal of soft tissue, and evaluated radiologically and histologically. Ectopic bones in the low-magnitude group (EBF model) had significantly greater wet weight and were significantly larger (macroscopically and radiographically) than those in the other two groups, whereas the size and wet weight of ectopic bones in the centrifuge acceleration group showed no significant difference compared those in control-CA group. All ectopic bones showed calcified trabeculae and maturated bone marrow. Micro-CT showed that bone volume (BV) in the low-magnitude group of EBF model was significantly higher than those in the other two groups (3.1±1.2mm3 v.s. 1.8±1.2mm3 in high-magnitude group and 1.3±0.9mm3 in control-VA group), but BV in the centrifuge acceleration group had no significant difference compared those in control-CA group. Union rate and BV in the low-magnitude group of RFH model were also significantly higher than those in the other groups (Union rate: 60% v.s. 0% in the high-magnitude group and 10% in the control-VA group, BV: 0.69±0.30mm3 v.s. 0.15±0.09mm3 in high-magnitude group and 0.22±0.17mm3 in control-VA group). BV/TV in the low-magnitude group of RFH model was significantly higher than that in control-VA group (59.4±14.9% v.s. 35.8±13.5%). On the other hand, radiographic union rate (10% in centrifuge acceleration group v.s. 20% in control-CA group) and micro-CT parameters in RFH model were not significantly different between two groups in the constant acceleration studies. Radiographic images of non-union rib fractures showed cartilage at the fracture site and poor new bone formation, whereas union samples showed only new bone. In conclusion, low-magnitude vibration acceleration promoted bone formation at the trunk in both BMP-induced ectopic bone formation and rib fracture healing models. However, the micro-CT parameters were not similar between two models, which suggested that there might be difference in the mechanism of effect by vibration between two models.
Collapse
Affiliation(s)
- Ryohei Uchida
- Department of Orthopedic Surgery, Osaka University Graduate School of Medicine, Osaka, Japan.,Department of Sports Medicine, Seifu Hospital, Osaka, Japan.,Department of Medicine for Sports and Performing Arts, Osaka University Graduate School of Medicine, Osaka, Japan
| | - Ken Nakata
- Department of Medicine for Sports and Performing Arts, Osaka University Graduate School of Medicine, Osaka, Japan
| | - Fuminori Kawano
- Department of Medicine for Sports and Performing Arts, Osaka University Graduate School of Medicine, Osaka, Japan
| | - Yasukazu Yonetani
- Department of Orthopedic Surgery, Osaka University Graduate School of Medicine, Osaka, Japan
| | - Issei Ogasawara
- Department of Medicine for Sports and Performing Arts, Osaka University Graduate School of Medicine, Osaka, Japan
| | - Naoya Nakai
- Department of Medicine for Sports and Performing Arts, Osaka University Graduate School of Medicine, Osaka, Japan
| | - Tatsuo Mae
- Department of Orthopedic Surgery, Osaka University Graduate School of Medicine, Osaka, Japan
| | - Tomohiko Matsuo
- Department of Orthopedic Surgery, Osaka University Graduate School of Medicine, Osaka, Japan
| | - Yuta Tachibana
- Department of Orthopedic Surgery, Osaka University Graduate School of Medicine, Osaka, Japan
| | - Hiroyuki Yokoi
- Department of Medicine for Sports and Performing Arts, Osaka University Graduate School of Medicine, Osaka, Japan
| | - Hideki Yoshikawa
- Department of Orthopedic Surgery, Osaka University Graduate School of Medicine, Osaka, Japan
| |
Collapse
|
50
|
Sá-Caputo DC, Dionello CDF, Frederico ÉHFF, Paineiras-Domingos LL, Sousa-Gonçalves CR, Morel DS, Moreira-Marconi E, Unger M, Bernardo-Filho M. WHOLE-BODY VIBRATION EXERCISE IMPROVES FUNCTIONAL PARAMETERS IN PATIENTS WITH OSTEOGENESIS IMPERFECTA: A SYSTEMATIC REVIEW WITH A SUITABLE APPROACH. AFRICAN JOURNAL OF TRADITIONAL, COMPLEMENTARY, AND ALTERNATIVE MEDICINES : AJTCAM 2017; 14:199-208. [PMID: 28480432 PMCID: PMC5412226 DOI: 10.21010/ajtcam.v14i3.22] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Indexed: 12/13/2022]
Abstract
BACKGROUND Patients with osteogenesis imperfecta (OI) have abnormal bone modelling and resorption. The bone tissue adaptation and responsivity to dynamic and mechanical loading may be of therapeutic use under controlled circumstances. Improvements due to the wholebody vibration (WBV) exercises have been reported in strength, motion, gait, balance, posture and bone density in several osteopenic individuals, as in post-menopausal women or children with disabling conditions, as patients with OI. The aim of this investigation was to systematically analyse the current available literature to determine the effect of WBV exercises on functional parameters of OI patients. MATERIALS AND METHODS Three reviewers independently accessed bibliographical databases. Searches were performed in the PubMed, Scopus, Science Direct and PEDro databases using keywords related to possible interventions (including WBV) used in the management of patients with osteogenesis imperfecta. RESULTS Three eligible studies were identified by searches in the analysed databases. CONCLUSION It was concluded that WBV exercises could be an important option in the management of OI patients improving the mobility and functional parameters. However, further studies are necessary for establishing suitable protocols for these patients.
Collapse
Affiliation(s)
- Danubia C Sá-Caputo
- Programa de Pâs-graduaçâo em Fisiopatologia Clínica e Experimental, Universidade do Estado do Rio de Janeiro, Rio de Janeiro, RJ, Brazil
- Departamento de Biofísica e Biometria, Instituto de Biologia Roberto Alcantara Gomes, Universidade do Estado do Rio de Janeiro, Rio de Janeiro, RJ, Brazil
| | - Carla da F Dionello
- Departamento de Biofísica e Biometria, Instituto de Biologia Roberto Alcantara Gomes, Universidade do Estado do Rio de Janeiro, Rio de Janeiro, RJ, Brazil
- Programa de Pâs-graduaçâo em Ciencias Médicas, Universidade do Estado do Rio de Janeiro, Rio de Janeiro, Brazil
| | - Éric Heleno F. F Frederico
- Departamento de Biofísica e Biometria, Instituto de Biologia Roberto Alcantara Gomes, Universidade do Estado do Rio de Janeiro, Rio de Janeiro, RJ, Brazil
| | - Laisa L Paineiras-Domingos
- Departamento de Biofísica e Biometria, Instituto de Biologia Roberto Alcantara Gomes, Universidade do Estado do Rio de Janeiro, Rio de Janeiro, RJ, Brazil
- Programa de Pâs-graduaçâo em Ciencias Médicas, Universidade do Estado do Rio de Janeiro, Rio de Janeiro, Brazil
| | - Cintia Renata Sousa-Gonçalves
- Departamento de Biofísica e Biometria, Instituto de Biologia Roberto Alcantara Gomes, Universidade do Estado do Rio de Janeiro, Rio de Janeiro, RJ, Brazil
| | - Danielle S Morel
- Departamento de Biofísica e Biometria, Instituto de Biologia Roberto Alcantara Gomes, Universidade do Estado do Rio de Janeiro, Rio de Janeiro, RJ, Brazil
- Programa de Pâs-graduaçâo em Ciencias Médicas, Universidade do Estado do Rio de Janeiro, Rio de Janeiro, Brazil
| | - Eloá Moreira-Marconi
- Programa de Pâs-graduaçâo em Fisiopatologia Clínica e Experimental, Universidade do Estado do Rio de Janeiro, Rio de Janeiro, RJ, Brazil
- Departamento de Biofísica e Biometria, Instituto de Biologia Roberto Alcantara Gomes, Universidade do Estado do Rio de Janeiro, Rio de Janeiro, RJ, Brazil
| | - Marianne Unger
- Division of Physiotherapy, Faculty of Medicine and Health Sciences, Stellenbosch University, South Africa
| | - Mario Bernardo-Filho
- Departamento de Biofísica e Biometria, Instituto de Biologia Roberto Alcantara Gomes, Universidade do Estado do Rio de Janeiro, Rio de Janeiro, RJ, Brazil
| |
Collapse
|