1
|
Desai A, Tankasala D, Ng GP, Thakkar P, Hoilett OS, Mather KJ, Linnes JC. Selective Collection of Exhaled Breath Condensate for Noninvasive Screening of Breath Glucose. J Diabetes Sci Technol 2025; 19:161-164. [PMID: 37401788 PMCID: PMC11688680 DOI: 10.1177/19322968231179728] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 07/05/2023]
Abstract
BACKGROUND Although exhaled breath condensate (EBC) is a promising noninvasive sample for detecting respiratory analytes such as glucose, current EBC collection methods yield inconsistent results. METHODS We developed a custom EBC collection device with a temperature-based algorithm to selectively condense alveolar air for reproducible EBC glucose detection. We characterized the condensate volumes and the corresponding glucose concentrations. We performed a pilot study demonstrating its use during oral glucose tolerance tests. RESULTS The novel device selectively captured alveolar air resulting in slightly higher and less variable glucose concentrations than the overall EBC. Participants with type 2 diabetes demonstrated significantly higher blood plasma-EBC glucose ratios than normoglycemic participants. CONCLUSIONS Temperature-based selective EBC collection allows EBC glucose measurement and is a promising sampling method to distinguish patients with and without diabetes.
Collapse
|
2
|
Kaysir MR, Zaman TM, Rassel S, Wang J, Ban D. Photoacoustic Resonators for Non-Invasive Blood Glucose Detection Through Photoacoustic Spectroscopy: A Systematic Review. SENSORS (BASEL, SWITZERLAND) 2024; 24:6963. [PMID: 39517861 PMCID: PMC11548572 DOI: 10.3390/s24216963] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 09/29/2024] [Revised: 10/24/2024] [Accepted: 10/25/2024] [Indexed: 11/16/2024]
Abstract
Diabetes mellitus is a prevalent disease with a rapidly increasing incidence projected worldwide, affecting both industrialized and developing regions. Effective diabetes management requires precise therapeutic strategies, primarily through self-monitoring of blood glucose levels to achieve tight glycemic control, thereby mitigating the risk of severe complications. In recent years, there have been significant advancements in non-invasive techniques for measuring blood glucose using photoacoustic spectroscopy (PAS), as it shows great promise for the detection of glucose using the infrared region (e.g., MIR and NIR) of light. A critical aspect of this method is the detection of the photoacoustic signal generated from blood glucose, which needs to be amplified through a photoacoustic resonator (PAR). In this work, an overview of various types of PARs used for non-invasive glucose sensing is reviewed, highlighting their operating principle, design requirements, limitations, and potential improvements needed to enhance the analysis of photoacoustic signals. The motivation behind this review is to identify and discuss main parameters crucial to the efficient design of PARs used in non-invasive glucose detection, which will be helpful for furthering the basic understanding of this technology and achieving the highly sensitive PAR required for non-invasive glucose monitoring.
Collapse
Affiliation(s)
- Md Rejvi Kaysir
- Department of Electrical and Electronic Engineering (EEE), Khulna University of Engineering & Technology (KUET), Khulna 9203, Bangladesh
- Photonics Research Group, Department of Electrical and Electronic Engineering (EEE), Khulna University of Engineering & Technology (KUET), Khulna 9203, Bangladesh
| | - Thasin Mohammad Zaman
- Department of Electrical and Electronic Engineering (EEE), Khulna University of Engineering & Technology (KUET), Khulna 9203, Bangladesh
- Photonics Research Group, Department of Electrical and Electronic Engineering (EEE), Khulna University of Engineering & Technology (KUET), Khulna 9203, Bangladesh
| | - Shazzad Rassel
- Department of Electrical and Computer Engineering, Tennessee State University, 3500 John A Merritt Blvd, Nashville, TN 37209, USA
- Department of Electrical and Computer Engineering, University of Waterloo, 200 University Ave. W, Waterloo, ON N2L 3G1, Canada
| | - Jishen Wang
- Department of Electrical and Computer Engineering, University of Waterloo, 200 University Ave. W, Waterloo, ON N2L 3G1, Canada
- Waterloo Institute for Nanotechnology, University of Waterloo, 200 University Ave. W, Waterloo, ON N2L 3G1, Canada
| | - Dayan Ban
- Department of Electrical and Computer Engineering, University of Waterloo, 200 University Ave. W, Waterloo, ON N2L 3G1, Canada
- Waterloo Institute for Nanotechnology, University of Waterloo, 200 University Ave. W, Waterloo, ON N2L 3G1, Canada
| |
Collapse
|
3
|
Li D, Zhang Y, Sun F, Felidj N, Gagey-Eilstein N, Lamouri A, Hémadi M, Nizard P, Luo Y, Mangeney C. Dual-Probe SERS Nanosensor: A Promising Approach for Sensitive and Ratiometric Detection of Glucose in Clinical Settings. ACS APPLIED BIO MATERIALS 2024; 7:2254-2263. [PMID: 38568747 DOI: 10.1021/acsabm.3c01250] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 04/05/2024]
Abstract
Diabetes is a major global health concern, with millions of annual deaths. Monitoring glucose levels is vital for clinical management, and urine samples offer a noninvasive alternative to blood samples. Optical techniques for urine glucose sensing have gained notable traction due to their cost-effectiveness and portability. Among these methods, surface-enhanced Raman spectroscopy (SERS) has attracted considerable attention thanks to its remarkable sensitivity and multiplexing capabilities. However, challenges remain in achieving reliable quantification through SERS. In this study, an alternative approach is proposed to enhance quantification involving the use of dual probes. Each probe is encoded with unique SERS signatures strategically positioned in the biologically silent region. One probe indicates the glucose presence, while the other acts as an internal reference for calibration. This setup enables ratiometric analysis of the SERS signal, directly correlating it with the glucose concentration. The fabrication of the sensor relies on the prefunctionalization of Fe sheets using an aryl diazonium salt bearing a -C≡CH group (internal reference), followed by the immobilization of Ag nanoparticles modified with an aryl diazonium salt bearing a -B(OH)2 group (for glucose capture). A secondary probe bearing a -B(OH)2 group on one side and a -C≡N group on the other side enables the ratiometric analysis by forming a sandwich-like structure in the presence of glucose (glucose indicator). Validation studies in aqueous solutions and artificial urine demonstrated the high spectral stability and the potential of this dual-probe nanosensor for sensitive glucose monitoring in clinical settings.
Collapse
Affiliation(s)
- Da Li
- Laboratoire de Chimie et de Biochimie Pharmacologiques et Toxicologiques, Université Paris Cité, CNRS, F-75006 Paris, France
| | - Yang Zhang
- Laboratoire de Chimie et de Biochimie Pharmacologiques et Toxicologiques, Université Paris Cité, CNRS, F-75006 Paris, France
| | - Fan Sun
- PSL Université, Chimie Paris Tech, IRCP, CNRS, F-75005 Paris, France
| | - Nordin Felidj
- Université Paris Cité, CNRS, ITODYS, F-75013 Paris, France
| | | | | | - Miryana Hémadi
- Université Paris Cité, CNRS, ITODYS, F-75013 Paris, France
| | - Philippe Nizard
- Laboratoire de Chimie et de Biochimie Pharmacologiques et Toxicologiques, Université Paris Cité, CNRS, F-75006 Paris, France
| | - Yun Luo
- Laboratoire de Chimie et de Biochimie Pharmacologiques et Toxicologiques, Université Paris Cité, CNRS, F-75006 Paris, France
| | - Claire Mangeney
- Laboratoire de Chimie et de Biochimie Pharmacologiques et Toxicologiques, Université Paris Cité, CNRS, F-75006 Paris, France
| |
Collapse
|
4
|
Monkrathok J, Janphuang P, Suphachiaraphan S, Kampaengsri S, Kamkaew A, Chansaenpak K, Lisnund S, Blay V, Pinyou P. Enhancing Glucose Biosensing with Graphene Oxide and Ferrocene-Modified Linear Poly(ethylenimine). BIOSENSORS 2024; 14:161. [PMID: 38667154 PMCID: PMC11048651 DOI: 10.3390/bios14040161] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 01/15/2024] [Revised: 03/25/2024] [Accepted: 03/26/2024] [Indexed: 04/28/2024]
Abstract
We designed and optimized a glucose biosensor system based on a screen-printed electrode modified with the NAD-GDH enzyme. To enhance the electroactive surface area and improve the electron transfer efficiency, we introduced graphene oxide (GO) and ferrocene-modified linear poly(ethylenimine) (LPEI-Fc) onto the biosensor surface. This strategic modification exploits the electrostatic interaction between graphene oxide, which possesses a negative charge, and LPEI-Fc, which is positively charged. This interaction results in increased catalytic current during glucose oxidation and helps improve the overall glucose detection sensitivity by amperometry. We integrated the developed glucose sensor into a flow injection (FI) system. This integration facilitates a swift and reproducible detection of glucose, and it also mitigates the risk of contamination during the analyses. The incorporation of an FI system improves the efficiency of the biosensor, ensuring precise and reliable results in a short time. The proposed sensor was operated at a constant applied potential of 0.35 V. After optimizing the system, a linear calibration curve was obtained for the concentration range of 1.0-40 mM (R2 = 0.986). The FI system was successfully applied to determine the glucose content of a commercial sports drink.
Collapse
Affiliation(s)
- Jirawan Monkrathok
- School of Chemistry, Institute of Science, Suranaree University of Technology, 111 University Ave., Nakhon Ratchasima 30000, Thailand; (J.M.); (S.K.); (A.K.)
| | - Pattanaphong Janphuang
- Synchrotron Light Research Institute (Public Organization), 111 University Ave., Nakhon Ratchasima 30000, Thailand; (P.J.); (S.S.)
| | - Somphong Suphachiaraphan
- Synchrotron Light Research Institute (Public Organization), 111 University Ave., Nakhon Ratchasima 30000, Thailand; (P.J.); (S.S.)
| | - Sastiya Kampaengsri
- School of Chemistry, Institute of Science, Suranaree University of Technology, 111 University Ave., Nakhon Ratchasima 30000, Thailand; (J.M.); (S.K.); (A.K.)
| | - Anyanee Kamkaew
- School of Chemistry, Institute of Science, Suranaree University of Technology, 111 University Ave., Nakhon Ratchasima 30000, Thailand; (J.M.); (S.K.); (A.K.)
| | - Kantapat Chansaenpak
- National Nanotechnology Center, National Science and Technology Development Agency, Thailand Science Park, Pathum Thani 12120, Thailand;
| | - Sireerat Lisnund
- Department of Applied Chemistry, Faculty of Science and Liberal Arts, Rajamangala University of Technology Isan, 744 Suranarai Rd., Nakhon Ratchasima 30000, Thailand;
| | - Vincent Blay
- Department of Microbiology and Environmental Toxicology, University of California at Santa Cruz, Santa Cruz, CA 95064, USA
| | - Piyanut Pinyou
- School of Chemistry, Institute of Science, Suranaree University of Technology, 111 University Ave., Nakhon Ratchasima 30000, Thailand; (J.M.); (S.K.); (A.K.)
| |
Collapse
|
5
|
Kaysir MR, Song J, Rassel S, Aloraynan A, Ban D. Progress and Perspectives of Mid-Infrared Photoacoustic Spectroscopy for Non-Invasive Glucose Detection. BIOSENSORS 2023; 13:716. [PMID: 37504114 PMCID: PMC10377086 DOI: 10.3390/bios13070716] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 03/26/2023] [Revised: 06/26/2023] [Accepted: 07/04/2023] [Indexed: 07/29/2023]
Abstract
The prevalence of diabetes is rapidly increasing worldwide and can lead to a range of severe health complications that have the potential to be life-threatening. Patients need to monitor and control blood glucose levels as it has no cure. The development of non-invasive techniques for the measurement of blood glucose based on photoacoustic spectroscopy (PAS) has advanced tremendously in the last couple of years. Among them, PAS in the mid-infrared (MIR) region shows great promise as it shows the distinct fingerprint region for glucose. However, two problems are generally encountered when it is applied to monitor real samples for in vivo measurements in this MIR spectral range: (i) low penetration depth of MIR light into the human skin, and (ii) the effect of other interfering components in blood, which affects the selectivity of the detection system. This review paper systematically describes the basics of PAS in the MIR region, along with recent developments, technical challenges, and data analysis strategies, and proposes improvements for the detection sensitivity of glucose concentration in human bodies. It also highlights the recent trends of incorporating machine learning (ML) to enhance the detection sensitivity of the overall system. With further optimization of the experimental setup and incorporation of ML, this PAS in the MIR spectral region could be a viable solution for the non-invasive measurement of blood glucose in the near future.
Collapse
Affiliation(s)
- Md Rejvi Kaysir
- Department of Electrical and Computer Engineering, University of Waterloo, 200 University Ave. W, Waterloo, ON N2L 3G1, Canada
- Waterloo Institute for Nanotechnology, University of Waterloo, 200 University Ave. W, Waterloo, ON N2L 3G1, Canada
- Department of Electrical and Electronic Engineering, Khulna University of Engineering & Technology, Khulna 9203, Bangladesh
| | - Jiaqi Song
- Department of Physics and Astronomy, University of Waterloo, 200 University Ave. W, Waterloo, ON N2L 3G1, Canada
| | - Shazzad Rassel
- Department of Electrical and Computer Engineering, University of Waterloo, 200 University Ave. W, Waterloo, ON N2L 3G1, Canada
- Waterloo Institute for Nanotechnology, University of Waterloo, 200 University Ave. W, Waterloo, ON N2L 3G1, Canada
| | - Abdulrahman Aloraynan
- Department of Electrical and Computer Engineering, University of Waterloo, 200 University Ave. W, Waterloo, ON N2L 3G1, Canada
- Waterloo Institute for Nanotechnology, University of Waterloo, 200 University Ave. W, Waterloo, ON N2L 3G1, Canada
| | - Dayan Ban
- Department of Electrical and Computer Engineering, University of Waterloo, 200 University Ave. W, Waterloo, ON N2L 3G1, Canada
- Waterloo Institute for Nanotechnology, University of Waterloo, 200 University Ave. W, Waterloo, ON N2L 3G1, Canada
| |
Collapse
|
6
|
Sasaki R, Kino S, Matsuura Y. Mid-infrared photoacoustic spectroscopy based on ultrasound detection for blood component analysis. BIOMEDICAL OPTICS EXPRESS 2023; 14:3841-3852. [PMID: 37497499 PMCID: PMC10368030 DOI: 10.1364/boe.494615] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 05/02/2023] [Revised: 06/21/2023] [Accepted: 06/22/2023] [Indexed: 07/28/2023]
Abstract
For the non-invasive measurement of biological tissue, a piezoelectric photoacoustic spectroscopy (PZT-PAS) system that detects a single frequency of ultrasound induced by the irradiation of pulse-modulated mid-infrared laser light was developed. PA spectra of the optical phantom and biological samples were obtained, and the relationship between the PA signal intensity and optical absorbance in the fingerprint region (930-1,200 cm-1) was analyzed to estimate the optical absorbance. The resonance vibration of the induced ultrasound was utilized to further increase the signal strength for biological tissue measurement. Consequently, PA spectrum reflecting the absorption of components in biological tissues was obtained.
Collapse
|
7
|
Pilat F, Schwarz B, Baumgartner B, Ristanić D, Detz H, Andrews AM, Lendl B, Strasser G, Hinkov B. Beyond Karl Fischer titration: a monolithic quantum cascade sensor for monitoring residual water concentration in solvents. LAB ON A CHIP 2023; 23:1816-1824. [PMID: 36800171 PMCID: PMC10045895 DOI: 10.1039/d2lc00724j] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 08/02/2022] [Accepted: 02/10/2023] [Indexed: 06/18/2023]
Abstract
Quality control of liquids is an important part of analytical chemistry. The gold standard for measuring residual water in organic solvents and pharmaceutical applications is Karl Fischer titration. It has a high sensitivity, selectivity and accuracy. The downsides are a time-consuming offline analysis, together with the need for toxic reagents producing waste, and it suffers from poor inter-laboratory reproducibility. In this work, we present a high-performance lab-on-a-chip sensor exploiting mid-IR spectroscopy for liquid sensing. It is operating at 6.1 μm wavelength and is suitable for robust and flexible real-time in situ analysis of the residual water concentration in isopropyl alcohol. This is demonstrated in two experiments. A custom-made 60 μL flow cell is employed to measure only minute amounts of analyte in an inline configuration. In a second approach, the whole sensor is immersed into the analyte to demonstrate sensitive and rapid in situ operation on the millisecond time scale. This is confirmed by the ability for time resolved single water-droplet monitoring, while they are mixed into the liquid sample. We obtain a limit of detection between 120 ppm and 150 ppm with a concentration coverage spanning three orders of magnitude from 1.2 × 10-2%vol to 25%vol for the flow cell and 1.5 × 10-2%vol to 19%vol in the in situ configuration, respectively.
Collapse
Affiliation(s)
- Florian Pilat
- Institute of Solid State Electronics and Center for Micro- and Nanostructures, TU Wien, 1040 Vienna, Austria.
| | - Benedikt Schwarz
- Institute of Solid State Electronics and Center for Micro- and Nanostructures, TU Wien, 1040 Vienna, Austria.
| | - Bettina Baumgartner
- Institute of Chemical Technologies and Analytics, TU Wien, 1060 Vienna, Austria
| | - Daniela Ristanić
- Institute of Solid State Electronics and Center for Micro- and Nanostructures, TU Wien, 1040 Vienna, Austria.
| | - Hermann Detz
- Institute of Solid State Electronics and Center for Micro- and Nanostructures, TU Wien, 1040 Vienna, Austria.
- Central European Institute of Technology (CEITEC), Brno University of Technology, 621 00 Brno, Czech Republic
| | - Aaron M Andrews
- Institute of Solid State Electronics and Center for Micro- and Nanostructures, TU Wien, 1040 Vienna, Austria.
| | - Bernhard Lendl
- Institute of Chemical Technologies and Analytics, TU Wien, 1060 Vienna, Austria
| | - Gottfried Strasser
- Institute of Solid State Electronics and Center for Micro- and Nanostructures, TU Wien, 1040 Vienna, Austria.
| | - Borislav Hinkov
- Institute of Solid State Electronics and Center for Micro- and Nanostructures, TU Wien, 1040 Vienna, Austria.
| |
Collapse
|
8
|
Fiedorova K, Augustynek M, Kubicek J, Kudrna P, Bibbo D. Review of present method of glucose from human blood and body fluids assessment. Biosens Bioelectron 2022; 211:114348. [DOI: 10.1016/j.bios.2022.114348] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/05/2021] [Revised: 03/22/2022] [Accepted: 05/05/2022] [Indexed: 12/15/2022]
|
9
|
Alimagham FC, Hutter D, Marco-García N, Gould E, Highland VH, Huefner A, Giorgi-Coll S, Killen MJ, Zakrzewska AP, Elliott SR, Carpenter KLH, Hutchinson PJ, Hutter T. Cerebral Microdialysate Metabolite Monitoring using Mid-infrared Spectroscopy. Anal Chem 2021; 93:11929-11936. [PMID: 34432431 PMCID: PMC8427560 DOI: 10.1021/acs.analchem.1c01149] [Citation(s) in RCA: 10] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/16/2021] [Accepted: 08/05/2021] [Indexed: 11/28/2022]
Abstract
The brains of patients suffering from traumatic brain-injury (TBI) undergo dynamic chemical changes in the days following the initial trauma. Accurate and timely monitoring of these changes is of paramount importance for improved patient outcome. Conventional brain-chemistry monitoring is performed off-line by collecting and manually transferring microdialysis samples to an enzymatic colorimetric bedside analyzer every hour, which detects and quantifies the molecules of interest. However, off-line, hourly monitoring means that any subhourly neurochemical changes, which may be detrimental to patients, go unseen and thus untreated. Mid-infrared (mid-IR) spectroscopy allows rapid, reagent-free, molecular fingerprinting of liquid samples, and can be easily integrated with microfluidics. We used mid-IR transmission spectroscopy to analyze glucose, lactate, and pyruvate, three relevant brain metabolites, in the extracellular brain fluid of two TBI patients, sampled via microdialysis. Detection limits of 0.5, 0.2, and 0.1 mM were achieved for pure glucose, lactate, and pyruvate, respectively, in perfusion fluid using an external cavity-quantum cascade laser (EC-QCL) system with an integrated transmission flow-cell. Microdialysates were collected hourly, then pooled (3-4 h), and measured consecutively using the standard ISCUSflex analyzer and the EC-QCL system. There was a strong correlation between the compound concentrations obtained using the conventional bedside analyzer and the acquired mid-IR absorbance spectra, where a partial-least-squares regression model was implemented to compute concentrations. This study demonstrates the potential utility of mid-IR spectroscopy for continuous, automated, reagent-free, and online monitoring of the dynamic chemical changes in TBI patients, allowing a more timely response to adverse brain metabolism and consequently improving patient outcomes.
Collapse
Affiliation(s)
- Farah C. Alimagham
- Department
of Chemistry, University of Cambridge, Cambridge CB2 1EW, United Kingdom
- Division
of Neurosurgery, Department of Clinical Neurosciences, University of Cambridge, Cambridge CB2 0QQ, United Kingdom
| | - Dan Hutter
- Department
of Electrical and Computer Engineering, The University of Texas at Austin, Austin, Texas 78712, United States
| | - Núria Marco-García
- Division
of Neurosurgery, Department of Clinical Neurosciences, University of Cambridge, Cambridge CB2 0QQ, United Kingdom
| | - Emma Gould
- Division
of Neurosurgery, Department of Clinical Neurosciences, University of Cambridge, Cambridge CB2 0QQ, United Kingdom
| | - Victoria H. Highland
- Department
of Chemistry, University of Cambridge, Cambridge CB2 1EW, United Kingdom
| | - Anna Huefner
- Department
of Chemistry, University of Cambridge, Cambridge CB2 1EW, United Kingdom
| | - Susan Giorgi-Coll
- Division
of Neurosurgery, Department of Clinical Neurosciences, University of Cambridge, Cambridge CB2 0QQ, United Kingdom
| | - Monica J. Killen
- Division
of Neurosurgery, Department of Clinical Neurosciences, University of Cambridge, Cambridge CB2 0QQ, United Kingdom
| | - Agnieszka P. Zakrzewska
- Division
of Neurosurgery, Department of Clinical Neurosciences, University of Cambridge, Cambridge CB2 0QQ, United Kingdom
| | - Stephen R. Elliott
- Department
of Chemistry, University of Cambridge, Cambridge CB2 1EW, United Kingdom
| | - Keri L. H. Carpenter
- Division
of Neurosurgery, Department of Clinical Neurosciences, University of Cambridge, Cambridge CB2 0QQ, United Kingdom
| | - Peter J. Hutchinson
- Division
of Neurosurgery, Department of Clinical Neurosciences, University of Cambridge, Cambridge CB2 0QQ, United Kingdom
| | - Tanya Hutter
- Materials
Science and Engineering Program and Texas Materials Institute, University of Texas at Austin, Austin, Texas 78712, United States
- Walker
Department of Mechanical Engineering, The
University of Texas at Austin, Austin, Texas 78712, United States
| |
Collapse
|
10
|
Zhang X, Cheng Y, Zhang Y. Mid-infrared ridge waveguides fabricated in CaF 2 crystal by the technique of O 5+ ion irradiation. APPLIED OPTICS 2021; 60:6302-6307. [PMID: 34613297 DOI: 10.1364/ao.426830] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 04/01/2021] [Accepted: 06/27/2021] [Indexed: 06/13/2023]
Abstract
The fabrication of ridge waveguides in calcium fluoride (CaF2) crystal working at the mid-infrared wavelength was studied. First, the planar waveguide was fabricated by using O5+ ion irradiation, and then the ridge waveguide structure was manufactured by precise diamond blade dicing. The propagation loss was measured by end-face coupling arrangement, and then annealing treatment was implemented to optimize the waveguide performance, and the propagation loss was finally reduced to 0.5 dB/cm. We measured the Raman spectra of the waveguide and substrate to observe the damage to the material lattice caused by O5+ ion irradiation technology.
Collapse
|
11
|
Dennyson Savariraj A, Salih A, Alam F, Elsherif M, AlQattan B, Khan AA, Yetisen AK, Butt H. Ophthalmic Sensors and Drug Delivery. ACS Sens 2021; 6:2046-2076. [PMID: 34043907 PMCID: PMC8294612 DOI: 10.1021/acssensors.1c00370] [Citation(s) in RCA: 25] [Impact Index Per Article: 6.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/20/2021] [Accepted: 05/17/2021] [Indexed: 12/15/2022]
Abstract
Advances in multifunctional materials and technologies have allowed contact lenses to serve as wearable devices for continuous monitoring of physiological parameters and delivering drugs for ocular diseases. Since the tear fluids comprise a library of biomarkers, direct measurement of different parameters such as concentration of glucose, urea, proteins, nitrite, and chloride ions, intraocular pressure (IOP), corneal temperature, and pH can be carried out non-invasively using contact lens sensors. Microfluidic contact lens sensor based colorimetric sensing and liquid control mechanisms enable the wearers to perform self-examinations at home using smartphones. Furthermore, drug-laden contact lenses have emerged as delivery platforms using a low dosage of drugs with extended residence time and increased ocular bioavailability. This review provides an overview of contact lenses for ocular diagnostics and drug delivery applications. The designs, working principles, and sensing mechanisms of sensors and drug delivery systems are reviewed. The potential applications of contact lenses in point-of-care diagnostics and personalized medicine, along with the significance of integrating multiplexed sensing units together with drug delivery systems, have also been discussed.
Collapse
Affiliation(s)
| | - Ahmed Salih
- Department
of Mechanical Engineering, Khalifa University
of Science and Technology, Abu Dhabi, United Arab Emirates
| | - Fahad Alam
- Department
of Mechanical Engineering, Khalifa University
of Science and Technology, Abu Dhabi, United Arab Emirates
| | - Mohamed Elsherif
- Department
of Mechanical Engineering, Khalifa University
of Science and Technology, Abu Dhabi, United Arab Emirates
| | - Bader AlQattan
- Department
of Mechanical Engineering, Khalifa University
of Science and Technology, Abu Dhabi, United Arab Emirates
| | - Ammar A. Khan
- Department
of Chemical Engineering, Imperial College
London, London SW7 2AZ, United Kingdom
| | - Ali K. Yetisen
- Department
of Physics, Lahore University of Management
Sciences, Lahore Cantonment 54792, Lahore, Pakistan
| | - Haider Butt
- Department
of Mechanical Engineering, Khalifa University
of Science and Technology, Abu Dhabi, United Arab Emirates
| |
Collapse
|
12
|
Bahmanpour S, Mahmoudi A. Application of Fresnel diffraction from the edge of a transparent plate to measurement of glucose concentration. APPLIED OPTICS 2021; 60:2893-2897. [PMID: 33798169 DOI: 10.1364/ao.420634] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 01/28/2021] [Accepted: 03/10/2021] [Indexed: 06/12/2023]
Abstract
We present a new method for measuring the solution concentration based on laser light diffraction from the edge of a glass plate immersed in the solution. It is shown experimentally that the visibility of diffraction fringes is varied periodically with solution concentration and the period is related to light wavelength and thickness of the glass plate. There are intervals of concentrations in which the visibility-concentration curve is very near to linear. By choosing a suitable glass plate, one can change the extent of measurable concentrations and the resolution of the method. Using a 1 mm thick glass plate, we obtained a resolution of7.67×10-6g/cc in the detection of glucose concentration. The presented method is accurate and much simpler than other methods for measuring the solution concentration.
Collapse
|
13
|
Crisan CV, Nichols HL, Wiesenfeld S, Steinbach G, Yunker PJ, Hammer BK. Glucose confers protection to Escherichia coli against contact killing by Vibrio cholerae. Sci Rep 2021; 11:2935. [PMID: 33536444 PMCID: PMC7858629 DOI: 10.1038/s41598-021-81813-4] [Citation(s) in RCA: 13] [Impact Index Per Article: 3.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/27/2020] [Accepted: 12/18/2020] [Indexed: 01/30/2023] Open
Abstract
Evolutionary arms races are broadly prevalent among organisms including bacteria, which have evolved defensive strategies against various attackers. A common microbial aggression mechanism is the type VI secretion system (T6SS), a contact-dependent bacterial weapon used to deliver toxic effector proteins into adjacent target cells. Sibling cells constitutively express immunity proteins that neutralize effectors. However, less is known about factors that protect non-sibling bacteria from T6SS attacks independently of cognate immunity proteins. In this study, we observe that human Escherichia coli commensal strains sensitive to T6SS attacks from Vibrio cholerae are protected when co-cultured with glucose. We confirm that glucose does not impair V. cholerae T6SS activity. Instead, we find that cells lacking the cAMP receptor protein (CRP), which regulates expression of hundreds of genes in response to glucose, survive significantly better against V. cholerae T6SS attacks even in the absence of glucose. Finally, we show that the glucose-mediated T6SS protection varies with different targets and killers. Our findings highlight the first example of an extracellular small molecule modulating a genetically controlled response for protection against T6SS attacks. This discovery may have major implications for microbial interactions during pathogen-host colonization and survival of bacteria in environmental communities.
Collapse
Affiliation(s)
- Cristian V Crisan
- School of Biological Sciences, Georgia Institute of Technology, Atlanta, GA, USA
- Parker H. Petit Institute for Bioengineering & Bioscience, Georgia Institute of Technology, Atlanta, GA, USA
- Center for Microbial Dynamics and Infection, Georgia Institute of Technology, Atlanta, GA, USA
| | - Holly L Nichols
- School of Biological Sciences, Georgia Institute of Technology, Atlanta, GA, USA
- Parker H. Petit Institute for Bioengineering & Bioscience, Georgia Institute of Technology, Atlanta, GA, USA
- Center for Microbial Dynamics and Infection, Georgia Institute of Technology, Atlanta, GA, USA
| | - Sophia Wiesenfeld
- School of Biological Sciences, Georgia Institute of Technology, Atlanta, GA, USA
- Parker H. Petit Institute for Bioengineering & Bioscience, Georgia Institute of Technology, Atlanta, GA, USA
- Center for Microbial Dynamics and Infection, Georgia Institute of Technology, Atlanta, GA, USA
| | - Gabi Steinbach
- Center for Microbial Dynamics and Infection, Georgia Institute of Technology, Atlanta, GA, USA
- School of Physics, Georgia Institute of Technology, Atlanta, GA, USA
| | - Peter J Yunker
- Center for Microbial Dynamics and Infection, Georgia Institute of Technology, Atlanta, GA, USA
- School of Physics, Georgia Institute of Technology, Atlanta, GA, USA
| | - Brian K Hammer
- School of Biological Sciences, Georgia Institute of Technology, Atlanta, GA, USA.
- Parker H. Petit Institute for Bioengineering & Bioscience, Georgia Institute of Technology, Atlanta, GA, USA.
- Center for Microbial Dynamics and Infection, Georgia Institute of Technology, Atlanta, GA, USA.
| |
Collapse
|
14
|
Rassel S, Xu C, Zhang S, Ban D. Noninvasive blood glucose detection using a quantum cascade laser. Analyst 2020; 145:2441-2456. [PMID: 32167098 DOI: 10.1039/c9an02354b] [Citation(s) in RCA: 16] [Impact Index Per Article: 3.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/09/2023]
Abstract
A Quantum Cascade Laser (QCL) was invented in the late 90s as a promising mid-infrared light source and it has contributed to the fields of industry, military, medicine, and biology. The room temperature operation, watt-level output power, compact size, and wide tuning capability of this laser advanced the field of noninvasive blood glucose detection with the use of transmission, absorption, and photoacoustic spectroscopy. This review provides a complete overview of the recent progress and technical details of these spectroscopy techniques, using QCL as an infrared light source for detecting blood glucose concentrations in diabetic patients.
Collapse
Affiliation(s)
- Shazzad Rassel
- Waterloo Institute for Nanotechnology and Department of Electrical and Computer Engineering, University of Waterloo, 200 University Ave W, Waterloo, ON N2L 3G1, Canada.
| | | | | | | |
Collapse
|
15
|
Stark C, Carvajal Arrieta CA, Behroozian R, Redmer B, Fiedler F, Müller S. Broadband polarimetric glucose determination in protein containing media using characteristic optical rotatory dispersion. BIOMEDICAL OPTICS EXPRESS 2019; 10:6340-6350. [PMID: 31853403 PMCID: PMC6913393 DOI: 10.1364/boe.10.006340] [Citation(s) in RCA: 10] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 07/25/2019] [Revised: 10/22/2019] [Accepted: 10/22/2019] [Indexed: 05/03/2023]
Abstract
One of the major challenges during polarimetric determination of glucose concentration is the spectral superposition with other optically active molecules, especially proteins like albumin. Since each of those substances has a characteristic optical rotatory dispersion (ORD), we developed a broadband polarimeter setup to distinguish between glucose and albumin. A partial least squares (PLS) regression with 5 components was applied to the polarimeter signal in the wavelength range of 380 - 680 nm . To verify the efficacy of the proposed method, different glucose levels of 0 - 500 mg/dl were spiked with varying albumin concentrations up to 1000 mg/dl . A standard error of prediction of ± 16.0 mg/dl was achieved compared to ± 128.3 mg/dl using a two-wavelength system with 532 nm and 635 nm under the same conditions.
Collapse
Affiliation(s)
- Christian Stark
- Lübeck University of Applied Sciences, Medical Sensors and Devices Laboratory, Mönkhofer Weg 239, Lübeck 23562, Germany
- University of Lübeck, Graduate School for Computing in Medicine and Life Sciences, Ratzeburger Allee 160, Lübeck 23562, Germany
| | - Cesar Andres Carvajal Arrieta
- Lübeck University of Applied Sciences, Medical Sensors and Devices Laboratory, Mönkhofer Weg 239, Lübeck 23562, Germany
| | - Reza Behroozian
- Lübeck University of Applied Sciences, Medical Sensors and Devices Laboratory, Mönkhofer Weg 239, Lübeck 23562, Germany
- University of Lübeck, Graduate School for Computing in Medicine and Life Sciences, Ratzeburger Allee 160, Lübeck 23562, Germany
| | - Benjamin Redmer
- Lübeck University of Applied Sciences, Medical Sensors and Devices Laboratory, Mönkhofer Weg 239, Lübeck 23562, Germany
- University of Lübeck, Graduate School for Computing in Medicine and Life Sciences, Ratzeburger Allee 160, Lübeck 23562, Germany
| | - Felix Fiedler
- Lübeck University of Applied Sciences, Medical Sensors and Devices Laboratory, Mönkhofer Weg 239, Lübeck 23562, Germany
- University of Lübeck, Graduate School for Computing in Medicine and Life Sciences, Ratzeburger Allee 160, Lübeck 23562, Germany
| | - Stefan Müller
- Lübeck University of Applied Sciences, Medical Sensors and Devices Laboratory, Mönkhofer Weg 239, Lübeck 23562, Germany
| |
Collapse
|
16
|
Yáñez E, Cywiak M, Franco S JM, Cywiak D. Gaussian beam with high spherical aberration focused by a singlet lens-shaped container for glucose measurements. APPLIED OPTICS 2019; 58:8495-8500. [PMID: 31873334 DOI: 10.1364/ao.58.008495] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 07/04/2019] [Accepted: 10/03/2019] [Indexed: 06/10/2023]
Abstract
We describe a highly sensitive optical technique for glucose concentration measurements in liquid samples based on measuring the heights of the primary sidelobes of the normalized intensity profiles of a focused Gaussian beam with high spherical aberration. A singlet lens-shaped container, filled with the sample under test, is used to focus the beam at an observation plane placed close to the focusing region. The normalized intensity profile of the aberrated beam allows for accurate measurement of the sample glucose concentration.
Collapse
|
17
|
Tankasala D, Linnes JC. Noninvasive glucose detection in exhaled breath condensate. Transl Res 2019; 213:1-22. [PMID: 31194942 PMCID: PMC6783357 DOI: 10.1016/j.trsl.2019.05.006] [Citation(s) in RCA: 21] [Impact Index Per Article: 3.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 03/03/2019] [Revised: 05/02/2019] [Accepted: 05/26/2019] [Indexed: 01/04/2023]
Abstract
Two-thirds of patients with diabetes avoid regularly monitoring their blood glucose levels because of the painful and invasive nature of current blood glucose detection. As an alternative to blood sample collection, exhaled breath condensate (EBC) has emerged as a promising noninvasive sample from which to monitor glucose levels. However, this dilute sample matrix requires sensors capable of detecting glucose with high resolution at nanomolar and micromolar concentrations. Recent developments in EBC collection methods and highly sensitive glucose biosensors provide a path toward enabling robust and sensitive glucose detection in EBC. This review addresses current and emerging EBC collection and glucose sensing modalities capable of quantifying glucose in EBC samples. We highlight the opportunities and challenges for development and integration of EBC glucose detection systems that will enable clinically robust and accurate EBC glucose measurements for improved glycemic control.
Collapse
Affiliation(s)
- Divya Tankasala
- Weldon School of Biomedical Engineering, Purdue University, West Lafayette, Indiana
| | - Jacqueline C Linnes
- Weldon School of Biomedical Engineering, Purdue University, West Lafayette, Indiana.
| |
Collapse
|
18
|
Villena Gonzales W, Mobashsher AT, Abbosh A. The Progress of Glucose Monitoring-A Review of Invasive to Minimally and Non-Invasive Techniques, Devices and Sensors. SENSORS (BASEL, SWITZERLAND) 2019; 19:E800. [PMID: 30781431 PMCID: PMC6412701 DOI: 10.3390/s19040800] [Citation(s) in RCA: 249] [Impact Index Per Article: 41.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 10/31/2018] [Revised: 01/20/2019] [Accepted: 01/22/2019] [Indexed: 02/07/2023]
Abstract
Current glucose monitoring methods for the ever-increasing number of diabetic people around the world are invasive, painful, time-consuming, and a constant burden for the household budget. The non-invasive glucose monitoring technology overcomes these limitations, for which this topic is significantly being researched and represents an exciting and highly sought after market for many companies. This review aims to offer an up-to-date report on the leading technologies for non-invasive (NI) and minimally-invasive (MI) glucose monitoring sensors, devices currently available in the market, regulatory framework for accuracy assessment, new approaches currently under study by representative groups and developers, and algorithm types for signal enhancement and value prediction. The review also discusses the future trend of glucose detection by analyzing the usage of the different bands in the electromagnetic spectrum. The review concludes that the adoption and use of new technologies for glucose detection is unavoidable and closer to become a reality.
Collapse
Affiliation(s)
- Wilbert Villena Gonzales
- School of Information Technology and Electrical Engineering, The University of Queensland, St Lucia, Brisbane 4072, Australia.
| | - Ahmed Toaha Mobashsher
- School of Information Technology and Electrical Engineering, The University of Queensland, St Lucia, Brisbane 4072, Australia.
| | - Amin Abbosh
- School of Information Technology and Electrical Engineering, The University of Queensland, St Lucia, Brisbane 4072, Australia.
| |
Collapse
|
19
|
Isensee K, Kröger-Lui N, Petrich W. Biomedical applications of mid-infrared quantum cascade lasers - a review. Analyst 2019; 143:5888-5911. [PMID: 30444222 DOI: 10.1039/c8an01306c] [Citation(s) in RCA: 31] [Impact Index Per Article: 5.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/24/2022]
Abstract
Mid-infrared spectroscopy has been applied to research in biology and medicine for more than 20 years and conceivable applications have been identified. More recently, these applications have been shown to benefit from the use of quantum cascade lasers due to their specific properties, namely high spectral power density, small beam parameter product, narrow emission spectrum and, if needed, tuning capabilities. This review provides an overview of the achievements and illustrates some applications which benefit from the key characteristics of quantum cascade laser-based mid-infrared spectroscopy using examples such as breath analysis, the investigation of serum, non-invasive glucose monitoring in bulk tissue and the combination of spectroscopy and microscopy of tissue thin sections for rapid histopathology.
Collapse
Affiliation(s)
- Katharina Isensee
- Kirchhoff-Institute for Physics, Heidelberg University, INF 277, 69120 Heidelberg, Germany.
| | | | | |
Collapse
|
20
|
Parachalil DR, Bruno C, Bonnier F, Blasco H, Chourpa I, Baker MJ, McIntyre J, Byrne HJ. Analysis of bodily fluids using vibrational spectroscopy: a direct comparison of Raman scattering and infrared absorption techniques for the case of glucose in blood serum. Analyst 2019; 144:3334-3346. [DOI: 10.1039/c9an00125e] [Citation(s) in RCA: 24] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/19/2022]
Abstract
Analysis of biomarkers present in the blood stream can potentially deliver crucial information on patient health and indicate the presence of numerous pathologies.
Collapse
Affiliation(s)
- Drishya Rajan Parachalil
- FOCAS Research Institute
- Technological University Dublin
- Dublin 8
- Ireland
- School of Physics and Optometric & Clinical Sciences
| | - Clément Bruno
- Université de Tours
- UFR sciences pharmaceutiques
- EA 6295 Nanomédicaments et Nanosondes
- 37200 Tours
- France
| | - Franck Bonnier
- Université de Tours
- UFR sciences pharmaceutiques
- EA 6295 Nanomédicaments et Nanosondes
- 37200 Tours
- France
| | - Hélène Blasco
- CHRU de Tours
- Laboratoire de Biochimie et Biologie Moléculaire
- Tours
- France
- WestCHEM
| | - Igor Chourpa
- Université de Tours
- UFR sciences pharmaceutiques
- EA 6295 Nanomédicaments et Nanosondes
- 37200 Tours
- France
| | - Matthew J. Baker
- WestCHEM
- Department of Pure & Applied Chemistry
- Technology and Innovation Centre
- University of Strathclyde
- Glasgow
| | - Jennifer McIntyre
- FOCAS Research Institute
- Technological University Dublin
- Dublin 8
- Ireland
| | - Hugh J. Byrne
- FOCAS Research Institute
- Technological University Dublin
- Dublin 8
- Ireland
| |
Collapse
|
21
|
Yáñez E, Cywiak M, Juan Manuel Franco S. Gaussian probe beam with high spherical aberration for glucose concentration measurement. APPLIED OPTICS 2018; 57:4153-4157. [PMID: 29791389 DOI: 10.1364/ao.57.004153] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 01/29/2018] [Accepted: 04/16/2018] [Indexed: 06/08/2023]
Abstract
We demonstrate that an optical probe beam with high spherical aberration used for glucose concentration measurements gives better sensitivity compared to a probe beam free of aberrations, under similar conditions. We place a singlet focusing lens at a large distance from a laser source with a Gaussian intensity profile to obtain a spherically aberrated probe beam with negligible truncation. The aberrated probe beam propagates through a transparent liquid sample. Intensity profiles of the transmitted beam are recorded by means of a homodyne profiler to perform the glucose concentration measurements accurately.
Collapse
|
22
|
Isensee K, Müller N, Pucci A, Petrich W. Towards a quantum cascade laser-based implant for the continuous monitoring of glucose. Analyst 2018; 143:6025-6036. [DOI: 10.1039/c8an01382a] [Citation(s) in RCA: 10] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/27/2023]
Abstract
Anin vitroinvestigation of a quantum cascade laser-based transflection optofluidic interface for the continuous glucose monitoring in biofluids is presented with respect to its glucose sensitivity and specificity, its glucose exchange time, its resistance against temperature variations and its long-term stability.
Collapse
Affiliation(s)
- Katharina Isensee
- Roche Diabetes Care GmbH
- 68305 Mannheim
- Germany
- Kirchhoff-Institute for Physics
- Heidelberg University
| | - Niklas Müller
- Kirchhoff-Institute for Physics
- Heidelberg University
- 69120 Heidelberg
- Germany
| | - Annemarie Pucci
- Kirchhoff-Institute for Physics
- Heidelberg University
- 69120 Heidelberg
- Germany
| | - Wolfgang Petrich
- Roche Diabetes Care GmbH
- 68305 Mannheim
- Germany
- Kirchhoff-Institute for Physics
- Heidelberg University
| |
Collapse
|
23
|
Bauer A, Hertzberg O, Küderle A, Strobel D, Pleitez MA, Mäntele W. IR-spectroscopy of skin in vivo: Optimal skin sites and properties for non-invasive glucose measurement by photoacoustic and photothermal spectroscopy. JOURNAL OF BIOPHOTONICS 2018; 11:e201600261. [PMID: 28417584 DOI: 10.1002/jbio.201600261] [Citation(s) in RCA: 25] [Impact Index Per Article: 3.6] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 10/11/2016] [Revised: 01/18/2017] [Accepted: 01/21/2017] [Indexed: 05/23/2023]
Abstract
We have reported two methods to analyze glucose in the interstitial fluid of skin based on mid-infrared excitation with a tunable quantum cascade laser and photoacoustic or photothermal detection. These methods were evaluated for optimum skin locations to obtain reproducible glucose information. The lower part of the arm, the hypothenar, the tips of the index finger and the thumb were tested. The thumb appears to be the optimal skin location, followed by the index finger. Basic requirements for an optimum site are good capillary blood perfusion, low Stratum corneum thickness and the absence of fat layers. To obtain a correlation on such a site, spectra were recorded on volunteers continuously after blood glucose manipulation. However, continuous measurements on an in vivo sample such as the skin have to cope with physiological alterations such as the formation of sweat. We have used both detection schemes to investigate the acid mantle reformation after washing during time scales similar to continuous measurements for calibration spectra. We found that reconstitution of the acid mantle of skin may be seen in less than one hour. Precleaning of the measurement site may thus be useful for intermittent, but not for long term continuous measurements.
Collapse
Affiliation(s)
- Alexander Bauer
- Institut für Biophysik, Goethe Universität Frankfurt, Max-von-Laue-Str. 1, D-60438 Frankfurt am Main, Germany
| | - Otto Hertzberg
- Institut für Biophysik, Goethe Universität Frankfurt, Max-von-Laue-Str. 1, D-60438 Frankfurt am Main, Germany
| | - Arne Küderle
- Institut für Biophysik, Goethe Universität Frankfurt, Max-von-Laue-Str. 1, D-60438 Frankfurt am Main, Germany
| | - Dominik Strobel
- Institut für Biophysik, Goethe Universität Frankfurt, Max-von-Laue-Str. 1, D-60438 Frankfurt am Main, Germany
| | - Miguel A Pleitez
- Helmholtz-Zentrum München, Institute for Biological and Medical Imaging, D-, 85764, Neuherberg, Germany
| | - Werner Mäntele
- Institut für Biophysik, Goethe Universität Frankfurt, Max-von-Laue-Str. 1, D-60438 Frankfurt am Main, Germany
| |
Collapse
|
24
|
Pleitez MA, Hertzberg O, Bauer A, Lieblein T, Glasmacher M, Tholl H, Mäntele W. Infrared reflectometry of skin: Analysis of backscattered light from different skin layers. SPECTROCHIMICA ACTA. PART A, MOLECULAR AND BIOMOLECULAR SPECTROSCOPY 2017; 184:220-227. [PMID: 28500960 DOI: 10.1016/j.saa.2017.04.080] [Citation(s) in RCA: 10] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 12/22/2016] [Revised: 04/26/2017] [Accepted: 04/29/2017] [Indexed: 05/25/2023]
Abstract
We have recently reported infrared spectroscopy of human skin in vivo using quantum cascade laser excitation and photoacoustic or photothermal detection for non-invasive glucose measurement . Here, we analyze the IR light diffusely reflected from skin layers for spectral contributions of glucose. Excitation of human skin by an external cavity tunable quantum cascade laser in the spectral region from 1000 to 1245cm-1, where glucose exhibits a fingerprint absorption, yields reflectance spectra with some contributions from glucose molecules. A simple three-layer model of skin was used to calculate the scattering intensities from the surface and from shallow and deeper layers using the Boltzmann radiation transfer equation. Backscattering of light at wavelengths around 10μm from the living skin occurs mostly from the Stratum corneum top layers and the shallow layers of the living epidermis. The analysis of the polarization of the backscattered light confirms this calculation. Polarization is essentially unchanged; only a very small fraction (<3%) is depolarized at 90° with respect to the laser polarization set at 0°. Based on these findings, we propose that the predominant part of the backscattered light is due to specular reflectance and to scattering from layers close to the surface. Diffusely reflected light from deeper layers undergoing one or more scattering processes would appear with significantly altered polarization. We thus conclude that a non-invasive glucose measurement based on backscattering of IR light from skin would have the drawback that only shallow layers containing some glucose at concentrations only weakly related to blood glucose are monitored.
Collapse
Affiliation(s)
- Miguel A Pleitez
- Institut für Biophysik; Goethe-Universität, Max-von-Laue-Straße 1, D-60438 Frankfurt am Main, Germany
| | - Otto Hertzberg
- DIEHL Stiftung & Co. KG, Stephanstraße 49, D-90478 Nürnberg, Germany.
| | - Alexander Bauer
- Institut für Biophysik; Goethe-Universität, Max-von-Laue-Straße 1, D-60438 Frankfurt am Main, Germany
| | - Tobias Lieblein
- Institut für Biophysik; Goethe-Universität, Max-von-Laue-Straße 1, D-60438 Frankfurt am Main, Germany
| | | | - Hans Tholl
- Diehl BGT Defence GmbH & Co. KG, Alte Nussdorfer Straße 13, D-88662 Überlingen, Germany
| | - Werner Mäntele
- Institut für Biophysik; Goethe-Universität, Max-von-Laue-Straße 1, D-60438 Frankfurt am Main, Germany.
| |
Collapse
|
25
|
Peng Y, Li G, Zhou M, Wang H, Lin L. Dynamic spectrum extraction method based on independent component analysis combined dual-tree complex wavelet transform. RSC Adv 2017. [DOI: 10.1039/c6ra28647j] [Citation(s) in RCA: 12] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/21/2022] Open
Abstract
The proposed new dynamic spectrum (DS) extraction method based on ICA combined DTCWT could improve the precision accuracy of non-invasive measurement of blood components effectively.
Collapse
Affiliation(s)
- Yao Peng
- State Key Laboratory of Precision Measurement Technology and Instruments
- Tianjin University
- Tianjin 300072
- China
- Tianjin Key Laboratory of Biomedical Detecting Techniques & Instruments
| | - Gang Li
- State Key Laboratory of Precision Measurement Technology and Instruments
- Tianjin University
- Tianjin 300072
- China
- Tianjin Key Laboratory of Biomedical Detecting Techniques & Instruments
| | - Mei Zhou
- Shanghai Key Laboratory of Multidimensional Information Processing
- East China Normal University
- Shanghai 200241
- China
| | - Huaile Wang
- State Key Laboratory of Precision Measurement Technology and Instruments
- Tianjin University
- Tianjin 300072
- China
- Tianjin Key Laboratory of Biomedical Detecting Techniques & Instruments
| | - Ling Lin
- State Key Laboratory of Precision Measurement Technology and Instruments
- Tianjin University
- Tianjin 300072
- China
- Tianjin Key Laboratory of Biomedical Detecting Techniques & Instruments
| |
Collapse
|
26
|
Schwaighofer A, Brandstetter M, Lendl B. Quantum cascade lasers (QCLs) in biomedical spectroscopy. Chem Soc Rev 2017; 46:5903-5924. [DOI: 10.1039/c7cs00403f] [Citation(s) in RCA: 102] [Impact Index Per Article: 12.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/16/2022]
Abstract
This review focuses on the recent applications of QCLs in mid-IR spectroscopy of clinically relevant samples.
Collapse
Affiliation(s)
- Andreas Schwaighofer
- Institute of Chemical Technologies and Analytics
- Vienna University of Technology
- 1060 Vienna
- Austria
| | | | - Bernhard Lendl
- Institute of Chemical Technologies and Analytics
- Vienna University of Technology
- 1060 Vienna
- Austria
| |
Collapse
|
27
|
Multiparameter Microwave Characterization and Probing of Ultralow Glucose Concentration Using a Microfabricated Biochip. MICROMACHINES 2016; 7:mi7060093. [PMID: 30404268 PMCID: PMC6189731 DOI: 10.3390/mi7060093] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 03/18/2016] [Revised: 05/01/2016] [Accepted: 05/13/2016] [Indexed: 12/24/2022]
Abstract
This paper presents a planar biochip consisting of electromagnetically coupled, symmetric, square open loops for the multiparameter microwave characterization of deionized water, a phosphate-buffered saline solution, and a fructose-deionized water solution. The characterization additionally includes the probing of an ultralow glucose concentration in a very small volume of human sera and in solutions of d-glucose powder and deionized water. The interaction between the coupled electromagnetic field and the aqueous solution sample translates into a predictable relationship between the electrical characteristics of the biochip (magnitude and phase of S-parameters, attenuation, phase constant, group delay, characteristic impedance, and effective complex permittivity) and the physical properties of the solution. Owing to the microfabrication technology used for fabricating the proposed microbiochip, it is possible to develop robust, compact square open loops with a microsized coupling gap that characterizes a very small volume (1 μL) of the sample. Additionally, the biochip's impedance peaks at its resonances were modeled using glucose-level-dependent coupling capacitance between folded square open loops and mutual inductance between center-loaded T-shaped stubs. These peaks linearly shifted in frequencies and markedly varied in impedance. Consequently, a physiologically relevant amount of glucose (50⁻400 mg/dL) with a high sensitivity (up to 2.036 Ω/(mg·dL-1)) and an ultralow detection limit (up to 4.8 nmol/L) was linearly detected.
Collapse
|
28
|
Xiao F, Wang L, Duan H. Nanomaterial based electrochemical sensors for in vitro detection of small molecule metabolites. Biotechnol Adv 2016; 34:234-49. [DOI: 10.1016/j.biotechadv.2016.01.006] [Citation(s) in RCA: 55] [Impact Index Per Article: 6.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/30/2015] [Revised: 01/24/2016] [Accepted: 01/28/2016] [Indexed: 12/25/2022]
|
29
|
Lin L, Zhang Q, Zhou M, Xu S, Li G. Calibration set selection method based on the “M + N” theory: application to non-invasive measurement by dynamic spectrum. RSC Adv 2016. [DOI: 10.1039/c6ra19272f] [Citation(s) in RCA: 29] [Impact Index Per Article: 3.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/21/2022] Open
Abstract
An appropriate method for calibration set selection is very important for a robust quantitative model, especially for the non-invasive measurement of blood components.
Collapse
Affiliation(s)
- Ling Lin
- State Key Laboratory of Precision Measurement Technology and Instruments
- Tianjin University
- Tianjin 300072
- China
- Tianjin Key Laboratory of Biomedical Detecting Techniques & Instruments
| | - Qirui Zhang
- State Key Laboratory of Precision Measurement Technology and Instruments
- Tianjin University
- Tianjin 300072
- China
- Tianjin Key Laboratory of Biomedical Detecting Techniques & Instruments
| | - Mei Zhou
- Shanghai Key Laboratory of Multidimensional Information Processing
- East China Normal University
- Shanghai 200241
- China
| | - Sijia Xu
- State Key Laboratory of Precision Measurement Technology and Instruments
- Tianjin University
- Tianjin 300072
- China
- Tianjin Key Laboratory of Biomedical Detecting Techniques & Instruments
| | - Gang Li
- State Key Laboratory of Precision Measurement Technology and Instruments
- Tianjin University
- Tianjin 300072
- China
- Tianjin Key Laboratory of Biomedical Detecting Techniques & Instruments
| |
Collapse
|
30
|
Liakat S, Bors KA, Xu L, Woods CM, Doyle J, Gmachl CF. Noninvasive in vivo glucose sensing on human subjects using mid-infrared light. BIOMEDICAL OPTICS EXPRESS 2014; 5:2397-404. [PMID: 25071973 PMCID: PMC4102373 DOI: 10.1364/boe.5.002397] [Citation(s) in RCA: 47] [Impact Index Per Article: 4.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 04/01/2014] [Revised: 05/31/2014] [Accepted: 06/16/2014] [Indexed: 05/02/2023]
Abstract
Mid-infrared quantum cascade laser spectroscopy is used to noninvasively predict blood glucose concentrations of three healthy human subjects in vivo. We utilize a hollow-core fiber based optical setup for light delivery and collection along with a broadly tunable quantum cascade laser to obtain spectra from human subjects and use standard chemo-metric techniques (namely partial least squares regression) for prediction analysis. Throughout a glucose concentration range of 80-160 mg/dL, we achieve clinically accurate predictions 84% of the time, on average. This work opens a new path to a noninvasive in vivo glucose sensor that would benefit the lives of hundreds of millions of diabetics worldwide.
Collapse
Affiliation(s)
- Sabbir Liakat
- Department of Electrical Engineering, Princeton University, Princeton, NJ 08544, USA
| | - Kevin A. Bors
- Department of Electrical Engineering, Princeton University, Princeton, NJ 08544, USA
| | - Laura Xu
- Department of Electrical Engineering, Princeton University, Princeton, NJ 08544, USA
| | - Callie M. Woods
- Department of Electrical Engineering, Princeton University, Princeton, NJ 08544, USA
| | - Jessica Doyle
- Department of Electrical Engineering, Princeton University, Princeton, NJ 08544, USA
- Permanent Address: Hunterdon Regional Central High School, Flemington, NJ 08822, USA
| | - Claire F. Gmachl
- Department of Electrical Engineering, Princeton University, Princeton, NJ 08544, USA
| |
Collapse
|
31
|
Yu S, Li D, Chong H, Sun C, Yu H, Xu K. In vitro glucose measurement using tunable mid-infrared laser spectroscopy combined with fiber-optic sensor. BIOMEDICAL OPTICS EXPRESS 2013; 5:275-86. [PMID: 24466493 PMCID: PMC3891338 DOI: 10.1364/boe.5.000275] [Citation(s) in RCA: 9] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 10/21/2013] [Revised: 12/06/2013] [Accepted: 12/07/2013] [Indexed: 05/20/2023]
Abstract
Because mid-infrared (mid-IR) spectroscopy is not a promising method to noninvasively measure glucose in vivo, a method for minimally invasive high-precision glucose determination in vivo by mid-IR laser spectroscopy combined with a tunable laser source and small fiber-optic attenuated total reflection (ATR) sensor is introduced. The potential of this method was evaluated in vitro. This research presents a mid-infrared tunable laser with a broad emission spectrum band of 9.19 to 9.77[Formula: see text](1024~1088 cm(-1)) and proposes a method to control and stabilize the laser emission wavelength and power. Moreover, several fiber-optic ATR sensors were fabricated and investigated to determine glucose in combination with the tunable laser source, and the effective sensing optical length of these sensors was determined for the first time. In addition, the sensitivity of this system was four times that of a Fourier transform infrared (FT-IR) spectrometer. The noise-equivalent concentration (NEC) of this laser measurement system was as low as 3.8 mg/dL, which is among the most precise glucose measurements using mid-infrared spectroscopy. Furthermore, a partial least-squares regression and Clarke error grid were used to quantify the predictability and evaluate the prediction accuracy of glucose concentration in the range of 5 to 500 mg/dL (physiologically relevant range: 30~400 mg/dL). The experimental results were clinically acceptable. The high sensitivity, tunable laser source, low NEC and small fiber-optic ATR sensor demonstrate an encouraging step in the work towards precisely monitoring glucose levels in vivo.
Collapse
Affiliation(s)
- Songlin Yu
- State Key Laboratory of Precision Measuring Technology & Instruments, Tianjin University No. 92, Weijin Road, Nankai District, Tianjin 300072, China
| | - Dachao Li
- State Key Laboratory of Precision Measuring Technology & Instruments, Tianjin University No. 92, Weijin Road, Nankai District, Tianjin 300072, China
| | - Hao Chong
- State Key Laboratory of Precision Measuring Technology & Instruments, Tianjin University No. 92, Weijin Road, Nankai District, Tianjin 300072, China
| | - Changyue Sun
- Tianjin Key Laboratory of Biomedical Detecting Techniques & Instruments, Tianjin University, No. 92, Weijin Road, Nankai District, Tianjin 300072, China
| | - Haixia Yu
- Tianjin Key Laboratory of Biomedical Detecting Techniques & Instruments, Tianjin University, No. 92, Weijin Road, Nankai District, Tianjin 300072, China
| | - Kexin Xu
- State Key Laboratory of Precision Measuring Technology & Instruments, Tianjin University No. 92, Weijin Road, Nankai District, Tianjin 300072, China
| |
Collapse
|