1
|
Sewer A, Talikka M, Calvino-Martin F, Luettich K, Iskandar A. Quantitative modeling of in vitro data using an adverse outcome pathway for the risk assessment of decreased lung function in humans. Toxicol Lett 2024; 393:107-113. [PMID: 38350531 DOI: 10.1016/j.toxlet.2024.02.001] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/29/2023] [Revised: 01/18/2024] [Accepted: 02/07/2024] [Indexed: 02/15/2024]
Abstract
In the absence of epidemiological data, there is a need to develop computational models that convert in vitro findings to human disease risk predictions following toxicant exposure. In such efforts, in vitro data can be evaluated in the context of adverse outcome pathways (AOPs) that organize mechanistic knowledge based on empirical evidence into a sequence of molecular-, cellular-, tissue-, and organ-level key events that precede an adverse outcome (AO). Here we combined data from advanced in vitro organotypic airway models exposed to combustible cigarette (CC) smoke or Tobacco Heating System (THS) aerosol with an AOP for increased oxidative stress leads to decreased lung function. The mathematical modeling predicted reduced risk of decreased ciliary beating frequency (CBF) based on oxidative stress measurements and reduced risk of decreased mucociliary clearance (MCC) based on CBF measurements in THS aerosol- compared with CC smoke-exposed cultures. To extend the predictions to the AO of decreased lung function, we leveraged human MCC data from current smokers, nonsmokers, former smokers, and users of heated tobacco products. This approach provided a plausible prediction of diminished reduction in lung function in response to THS use compared with continued smoking. The current approach may also present a basis for an integrated approach to testing and assessment of tobacco products for future regulatory decision-making.
Collapse
Affiliation(s)
- Alain Sewer
- PMI R&D, Philip Morris Products S.A., Neuchâtel, Switzerland.
| | - Marja Talikka
- PMI R&D, Philip Morris Products S.A., Neuchâtel, Switzerland
| | | | - Karsta Luettich
- PMI R&D, Philip Morris Products S.A., Neuchâtel, Switzerland
| | - Anita Iskandar
- PMI R&D, Philip Morris Products S.A., Neuchâtel, Switzerland
| |
Collapse
|
2
|
Kopa-Stojak PN, Pawliczak R. Comparison of the effects of active and passive smoking of tobacco cigarettes, electronic nicotine delivery systems and tobacco heating products on the expression and secretion of oxidative stress and inflammatory response markers. A systematic review. Inhal Toxicol 2024; 36:75-89. [PMID: 38394073 DOI: 10.1080/08958378.2024.2319315] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/16/2023] [Accepted: 02/09/2024] [Indexed: 02/25/2024]
Abstract
OBJECTIVES This work attempts to summarize current knowledge on the effects of active and passive smoking of cigarettes, electronic nicotine delivery systems and tobacco heating products on the expression and secretion of oxidative stress and inflammatory response mediators, and on their possible impact on chronic obstructive pulmonary disease development. MATERIALS AND METHODS The literature was searched by the terms: 'smoking', 'active smoking', 'passive smoking', 'main-stream smoke', 'side-stream smoke', 'secondhand smoke', 'cigarette' 'THP', 'tobacco heating product', 'ENDS', 'electronic nicotine delivery system', 'e-cigarette', 'electronic cigarette', oxidative stress', inflammatory response' and 'gene expression'. RESULTS Cigarette smoking (active and passive) induces oxidative stress and inflammatory response in the airways. We present the effect of active smoking of e-cigarettes (EC) and heat-not-burn (HnB) products on the increased expression and secretion of oxidative stress and inflammatory response markers. However, there is only a limited number of studies on the effect of their second-hand smoking, and those available mainly describe aerosol composition. DISCUSSION The literature provides data which confirm that active and passive cigarette smoking induces oxidative stress and inflammatory response in the airways and is a key risk factor of COPD development. Currently, there is a limited number of data about ENDS and THP active and passive smoking effects on the health of smokers and never-smokers. It is particularly important to assess the effect of such products during long-term use by never-smokers who choose them as the first type of cigarettes, and for never-smokers who are passively exposed to their aerosol.
Collapse
Affiliation(s)
- Paulina Natalia Kopa-Stojak
- Department of Immunopathology, Division of Biomedical Science, Faculty of Medicine, Medical University of Lodz, Lodz, Poland
| | - Rafal Pawliczak
- Department of Immunopathology, Division of Biomedical Science, Faculty of Medicine, Medical University of Lodz, Lodz, Poland
| |
Collapse
|
3
|
Tratnjek L, Simić L, Vukelić K, Knežević Z, Kreft ME. Novel nasal formulation of xylometazoline with hyaluronic acid: In vitro ciliary beat frequency study. Eur J Pharm Biopharm 2023; 192:136-146. [PMID: 37804998 DOI: 10.1016/j.ejpb.2023.10.002] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/11/2023] [Revised: 08/31/2023] [Accepted: 10/02/2023] [Indexed: 10/09/2023]
Abstract
Acute viral rhinosinusitis (viral ARS), or commonly referred to as the "common cold", is caused by respiratory viruses that cause disruption of the airway epithelial barrier and mucociliary dysfunction. Treatment of ARS is mainly symptomatic, with xylometazoline, a direct-acting α-adrenoceptor agonist, commonly used as a nasal decongestant. Unfortunately, this treatment does not resolve the epithelial dysfunction observed in ARS, and its use might negatively impact the nasal mucosa causing issues such as dryness, stinging, burning, rebound congestion, as well as atrophy. In light of this, a novel nasal spray formulation containing both xylometazoline and hyaluronic acid (HA) was developed to provide a more effective and safer treatment for viral ARS. HA is a natural polysaccharide known to hydrate and moisturise the upper respiratory tract, maintain the integrity of the nasal mucosa, and promote mucociliary clearance and wound healing. To investigate the potential of this combination, this study was conducted using the nasal MucilAirTMin vitro model and high-speed phase-contrast microscopy to examine the effect of xylometazoline and HA on ciliary function by measuring ciliary beat frequency and their cytotoxicity by morphological, histological and ultrastructural analysis. This research is the first to assess the effects of a specific dose and molecular weight of HA as an active pharmaceutical ingredient in nasal spray formulations. The combination of a fast-acting decongestant and an additional active agent targeting nasal epithelial dysfunction has the potential to provide an improved, reliable and safe treatment for viral ARS, and may serve as the basis for future clinical studies.
Collapse
Affiliation(s)
- Larisa Tratnjek
- Institute of Cell Biology, Faculty of Medicine, University of Ljubljana, Vrazov trg 2, 1000 Ljubljana, Slovenia
| | - Laura Simić
- Jadran-galenski Laboratorij d.d., Svilno 20, 51 000 Rijeka, Croatia
| | - Karina Vukelić
- Jadran-galenski Laboratorij d.d., Svilno 20, 51 000 Rijeka, Croatia
| | - Zdravka Knežević
- Jadran-galenski Laboratorij d.d., Svilno 20, 51 000 Rijeka, Croatia
| | - Mateja Erdani Kreft
- Institute of Cell Biology, Faculty of Medicine, University of Ljubljana, Vrazov trg 2, 1000 Ljubljana, Slovenia.
| |
Collapse
|
4
|
Su M, Li X, Li Z, Hua C, Shang P, Zhao J, Liu K, Xie F. Design of a microfluidic lung chip and its application in assessing the toxicity of formaldehyde. Toxicol Mech Methods 2023; 33:427-436. [PMID: 36573377 DOI: 10.1080/15376516.2022.2159903] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/18/2022] [Revised: 11/28/2022] [Accepted: 12/13/2022] [Indexed: 12/28/2022]
Abstract
In this work, a microfluidic lung chip with membrane supporting cell growth that can produce multiple concentration gradients of gas and liquid is introduced. The chip is composed of a gas gradient layer in the upper part, a porous membrane supporting cell growth in the middle and a liquid gradient layer in the lower part. The gas-liquid interface environment of the cells on the membrane can expose the cells to the gas in the upper layer and the liquid in the lower layer at the same time. Then, the chip is applied to the toxicity testing of formaldehyde in A549 cells. The results showed that at 6 × 10-5 mol/L formaldehyde, the survival rate of the cells in four channels were 90, 87, 81, and 71%, which shows a dose-response trend under the influence of different concentrations of formaldehyde. ROS staining results also showed that formaldehyde exposure at 6 × 10-5 mol/L lead to the increase of ROS level in the cells. These results suggest that the chip based on cell growth on membrane could be used for toxicological evaluation of environmental polluting gases.
Collapse
Affiliation(s)
- Man Su
- Key Laboratory of Tobacco Chemistry, Zhengzhou Tobacco Research Institute of CNTC, Zhengzhou, P. R. China
| | - Xiang Li
- Key Laboratory of Tobacco Chemistry, Zhengzhou Tobacco Research Institute of CNTC, Zhengzhou, P. R. China
| | - Zezhi Li
- Beijing Technology and Business University, Beijing, P. R. China
| | - Chenfeng Hua
- Key Laboratory of Tobacco Chemistry, Zhengzhou Tobacco Research Institute of CNTC, Zhengzhou, P. R. China
| | - Pingping Shang
- Key Laboratory of Tobacco Chemistry, Zhengzhou Tobacco Research Institute of CNTC, Zhengzhou, P. R. China
| | - Junwei Zhao
- Key Laboratory of Tobacco Chemistry, Zhengzhou Tobacco Research Institute of CNTC, Zhengzhou, P. R. China
| | - Kejian Liu
- Key Laboratory of Tobacco Chemistry, Zhengzhou Tobacco Research Institute of CNTC, Zhengzhou, P. R. China
| | - Fuwei Xie
- Key Laboratory of Tobacco Chemistry, Zhengzhou Tobacco Research Institute of CNTC, Zhengzhou, P. R. China
| |
Collapse
|
5
|
Johne S, van der Toorn M, Iskandar AR, Majeed S, Torres LO, Hoeng J, Peitsch MC. An in vitro evaluation of e-vapor products: The contributions of chemical adulteration, concentration, and device power. Food Chem Toxicol 2023; 175:113708. [PMID: 36889430 DOI: 10.1016/j.fct.2023.113708] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/12/2023] [Revised: 02/21/2023] [Accepted: 03/04/2023] [Indexed: 03/08/2023]
Abstract
Homemade e-liquids and power-adjustable vaping devices may carry higher risks than commercial formulations and fixed-power devices. This study used human macrophage-like and bronchial epithelial (NHBE) cell cultures to investigate toxicity of homemade e-liquids containing propylene glycol and vegetable glycerin (PG/VG), nicotine, vitamin E acetate (VEA), medium-chain fatty acids (MCFAs), phytol, and cannabidiol (CBD). SmallAir™ organotypic epithelial cultures were exposed to aerosols generated at different power settings (10-50 W). Carbonyl levels were measured, and endpoints reflecting epithelial function (ciliary beating frequency [CBF]), integrity (transepithelial electrical resistance [TEER]), and structure (histology) were investigated. Treatment with nicotine or VEA alone or with PG/VG did not impact cell viability. CBD, phytol, and lauric acid caused cytotoxicity in both culture systems and increased lipid-laden macrophages. Exposure of SmallAir™ organotypic cultures to CBD-containing aerosols resulted in tissue injury and loss of CBF and TEER, while PG/VG alone or with nicotine or VEA did not. Aerosols generated with higher power settings had higher carbonyl concentrations. In conclusion, the presence and concentration of certain chemicals and device power may induce cytotoxicity in vitro. These results raise concerns that power-adjustable devices may generate toxic compounds and suggest that toxicity assessments should be conducted for both e-liquid formulations and their aerosols.
Collapse
Affiliation(s)
- Stephanie Johne
- PMI R&D, Philip Morris Products S.A, Quai Jeanrenaud 5, 2000, Neuchâtel, Switzerland.
| | - Marco van der Toorn
- PMI R&D, Philip Morris Products S.A, Quai Jeanrenaud 5, 2000, Neuchâtel, Switzerland
| | - Anita R Iskandar
- PMI R&D, Philip Morris Products S.A, Quai Jeanrenaud 5, 2000, Neuchâtel, Switzerland
| | - Shoaib Majeed
- PMI R&D, Philip Morris Products S.A, Quai Jeanrenaud 5, 2000, Neuchâtel, Switzerland
| | - Laura O Torres
- PMI R&D, Philip Morris Products S.A, Quai Jeanrenaud 5, 2000, Neuchâtel, Switzerland
| | - Julia Hoeng
- PMI R&D, Philip Morris Products S.A, Quai Jeanrenaud 5, 2000, Neuchâtel, Switzerland
| | - Manuel C Peitsch
- PMI R&D, Philip Morris Products S.A, Quai Jeanrenaud 5, 2000, Neuchâtel, Switzerland
| |
Collapse
|
6
|
Chapman F, Pour SJ, Wieczorek R, Trelles Sticken E, Budde J, Röwer K, Otte S, Mason E, Czekala L, Nahde T, O'Connell G, Simms L, Stevenson M. Twenty-eight day repeated exposure of human 3D bronchial epithelial model to heated tobacco aerosols indicates decreased toxicological responses compared to cigarette smoke. FRONTIERS IN TOXICOLOGY 2023; 5:1076752. [PMID: 36875887 PMCID: PMC9979258 DOI: 10.3389/ftox.2023.1076752] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/21/2022] [Accepted: 01/09/2023] [Indexed: 02/18/2023] Open
Abstract
Tobacco harm reduction (THR) involves providing adult smokers with potentially reduced harm modes of nicotine delivery as alternatives to smoking combustible cigarettes. Heated tobacco products (HTPs) form a category with THR potential due to their ability to deliver nicotine and flavours through heating, not burning, tobacco. By eliminating burning, heated tobacco does not produce smoke but an aerosol which contains fewer and lower levels of harmful chemicals compared to cigarette smoke. In this study we assessed the in vitro toxicological profiles of two prototype HTPs' aerosols compared to the 1R6F reference cigarette using the 3D human (bronchial) MucilAir™ model. To increase consumer relevance, whole aerosol/smoke exposures were delivered repeatedly across a 28 day period (16, 32, or 48 puffs per exposure). Cytotoxicity (LDH secretion), histology (Alcian Blue/H&E; Muc5AC; FoxJ1 staining), cilia active area and beat frequency and inflammatory marker (IL-6; IL-8; MMP-1; MMP-3; MMP-9; TNFα) levels were assessed. Diluted 1R6F smoke consistently induced greater and earlier effects compared to the prototype HTP aerosols across the endpoints, and in a puff dependent manner. Although some significant changes across the endpoints were induced by exposure to the HTPs, these were substantially less pronounced and less frequently observed, with apparent adaptive responses occurring over the experimental period. Furthermore, these differences between the two product categories were observed at a greater dilution (and generally lower nicotine delivery range) for 1R6F (1R6F smoke diluted 1/14, HTP aerosols diluted 1/2, with air). Overall, the findings demonstrate the THR potential of the prototype HTPs through demonstrated substantial reductions in toxicological outcomes in in vitro 3D human lung models.
Collapse
Affiliation(s)
| | | | | | | | | | - Karin Röwer
- Reemtsma Cigarettenfabriken GmbH, Hamburg, Germany
| | - Sandra Otte
- Reemtsma Cigarettenfabriken GmbH, Hamburg, Germany
| | | | | | - Thomas Nahde
- Reemtsma Cigarettenfabriken GmbH, Hamburg, Germany
| | | | - Liam Simms
- Imperial Brands PLC, Bristol, United Kingdom
| | | |
Collapse
|
7
|
Chemical and in vitro toxicological comparison of emissions from a heated tobacco product and the 1R6F reference cigarette. Toxicol Rep 2023; 10:281-292. [PMID: 36876026 PMCID: PMC9976195 DOI: 10.1016/j.toxrep.2023.02.005] [Citation(s) in RCA: 4] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/06/2022] [Revised: 02/06/2023] [Accepted: 02/14/2023] [Indexed: 02/17/2023] Open
Abstract
It has previously been found that, compared with cigarette smoke, the aerosols generated by heated tobacco products contain fewer and lower harmful and potentially harmful constituents (HPHCs) and elicit lower biological activity in in vitro models and lower smoking-related exposure biomarker levels in clinical studies. It is important to accumulate such scientific evidences for heated tobacco products with a novel heating system, because different heating system may affect the quantitative aspect of the amount of HPHCs and the qualitative aspect of the biological activity of the aerosol generated. Here, the chemical properties of, and toxicological responses to aerosols emitted by DT3.0a, a new heated tobacco product with a novel heating system, and cigarette smoke (CS) were compared, using chemical analyses, in vitro battery (standardized genotoxicity and cytotoxicity) assays, and mechanistic (ToxTracker and two-dimensional cell culture) assays. Regular- and menthol-flavored DT3.0a and standard 1R6F reference cigarettes were tested. Selected HPHC yields were lower in DT3.0a aerosol than 1R6F CS. The genotoxicity-related assays indicated that DT3.0a aerosol was not genotoxic, regardless of metabolic activation. The other biological assays indicated that less cytotoxicity induction and oxidative stress response were elicited by DT3.0a aerosol compared with 1R6F CS. Similar results were found for both regular and menthol DT3.0a. Like previous reports for heated tobacco products with other heating systems, the results of this study indicated that DT3.0a aerosols have chemical and biological properties less likely to be harmful than 1R6F CS.
Collapse
Key Words
- ACM, aerosol collected mass
- ARE, anti-oxidant responsive element
- AqE, aqueous extract
- BDL, below detection limit
- CMF-PBS, calcium- and magnesium-free phosphate buffered saline
- CS, cigarette smoke
- Cytotoxicity
- DT3.0a, Direct Heating Tobacco System Platform 3 generation 3 version a
- GFP, green fluorescent protein
- GVP, gas-vapor phase
- Genotoxicity
- HPHCs
- HPHCs, harmful and potentially harmful constituents
- HTP, heated tobacco product
- Heated tobacco product
- IC50, half maximal inhibitory concentration
- ISO, International Organization for Standardization
- In vitro
- LOD, limit of detection
- LOQ, limit of quantification
- MLA, mouse lymphoma assay
- MN, micronucleus
- MRTP, modified risk tobacco product
- NQ, not quantified
- NRU, neutral red uptake
- Oxidative stress
- ROS, reactive oxygen species
- THP, tobacco heating product
- THS, tobacco heating system
- TPM, total particulate matter
- mES, mouse embryonic stem
Collapse
|
8
|
Bovard D, van der Toorn M, Schlage WK, Constant S, Renggli K, Peitsch MC, Hoeng J. Iota-carrageenan extracted from red algae is a potent inhibitor of SARS-CoV-2 infection in reconstituted human airway epithelia. Biochem Biophys Rep 2021; 29:101187. [PMID: 34931176 PMCID: PMC8673819 DOI: 10.1016/j.bbrep.2021.101187] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/15/2021] [Revised: 12/09/2021] [Accepted: 12/09/2021] [Indexed: 11/13/2022] Open
Abstract
Iota-carrageenan (IC) nasal spray, a medical device approved for treating respiratory viral infections, has previously been shown to inhibit the ability of a variety of respiratory viruses, including severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2), to enter and replicate in the cell by interfering with the virus binding to the cell surface. The aim of this study was to further investigate the efficacy and safety of IC in SARS-CoV-2 infection in advanced in vitro models of the human respiratory epithelium, the primary target and entry port for SARS-CoV-2. We extended the in vitro safety assessment of nebulized IC in a 3-dimensional model of reconstituted human bronchial epithelium, and we demonstrated the efficacy of IC in protecting reconstituted nasal epithelium against viral infection and replication of a patient-derived SARS-CoV-2 strain. The results obtained from these two advanced models of human respiratory tract epithelia confirm previous findings from in vitro SARS-CoV-2 infection assays and demonstrate that topically applied IC can effectively prevent SARS-CoV-2 infection and replication. Moreover, the absence of toxicity and functional and structural impairment of the mucociliary epithelium demonstrates that the nebulized IC is well tolerated. IC had a potent antiviral effect in SARS-CoV-2 infected organotypic nasal epithelial cultures. Topical application (nasal drops) was non-toxic at anti-virally efficient doses. Aerosolized IC had no adverse effects on reconstituted human bronchial epithelium.
Collapse
Key Words
- 3D, 3-dimensional
- AE, after exposure
- ALI, air–liquid interface
- Air–liquid interface
- BE, before exposure
- Bronchial epithelium
- CBF, ciliary beating frequency
- COVID-19
- COVID19, Coronavirus disease 2019
- DMMB, Dimethylmethylene blue
- IC, Iota-carrageenan
- Iota-carrageenan
- LDH, lactate dehydrogenase
- MOI, multiplicity of infection
- NHBE, normal human bronchial epithelial
- Nasal epithelium
- Nasal spray
- PBS, phosphate-buffered saline
- SARS-CoV-2
- SARS-CoV-2, severe acute respiratory syndrome coronavirus 2
- SSPL, spike-pseudotyped lentivirus
- TEER, transepithelial electrical resistance
- hACE2, human angiotensin I-converting enzyme 2
Collapse
Affiliation(s)
- David Bovard
- PMI R&D, Philip Morris Products S.A, Quai Jeanrenaud 5, 2000, Neuchâtel, Switzerland
| | - Marco van der Toorn
- PMI R&D, Philip Morris Products S.A, Quai Jeanrenaud 5, 2000, Neuchâtel, Switzerland
| | - Walter K Schlage
- Biology Consultant, Max-Baermann-Str. 21, 51429, Bergisch Gladbach, Germany
| | - Samuel Constant
- Epithelix Sarl, 18 Chemin des Aulx, Plan-les-Ouates, 1228, Geneva, Switzerland
| | - Kasper Renggli
- PMI R&D, Philip Morris Products S.A, Quai Jeanrenaud 5, 2000, Neuchâtel, Switzerland
| | - Manuel C Peitsch
- PMI R&D, Philip Morris Products S.A, Quai Jeanrenaud 5, 2000, Neuchâtel, Switzerland
| | - Julia Hoeng
- PMI R&D, Philip Morris Products S.A, Quai Jeanrenaud 5, 2000, Neuchâtel, Switzerland
| |
Collapse
|
9
|
Nishino K, Tamai K, Orita K, Hashimoto Y, Nakamura H. Heated Tobacco Products Impair Cell Viability, Osteoblastic Differentiation, and Bone Fracture-Healing. J Bone Joint Surg Am 2021; 103:2024-2031. [PMID: 34730563 DOI: 10.2106/jbjs.20.02227] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 02/01/2023]
Abstract
BACKGROUND The negative impact of cigarette smoking on bone union has been well documented. However, the impact of heated tobacco product (HTP) use on bone fracture-healing remains unclear. The present study investigated the effect of HTPs on preosteoblast viability, osteoblastic differentiation, and fracture-healing and compared the effects with those of conventional combustible cigarettes. METHODS Cigarette smoke extracts (CSEs) were generated from combustible cigarettes (cCSE) and HTPs (hCSE). CSE concentrations were standardized by assessing optical density. Preosteoblast (MC3T3-E1) cells were incubated with normal medium, cCSE, or hCSE. The cell viability was assessed via MTT assay. After osteoblastic differentiation of CSE-exposed cells, alkaline phosphatase (ALP) activity was assessed. To assess the in vivo effects of CSEs, a femoral midshaft osteotomy was performed in a rat model; thereafter, saline solution, cCSE, or hCSE was injected intraperitoneally, and bone union was assessed on the basis of micro-computed tomography (μCT) and biomechanical analysis 4 weeks later. RESULTS MC3T3-E1 cell viability was reduced in a time and concentration-dependent manner when treated with either cCSE or hCSE. ALP activity after osteoblastic differentiation of cCSE-treated cells was significantly lower than that of both untreated and hCSE-treated cells (mean and standard deviation, 452.4 ± 48.8 [untreated], 326.2 ± 26.2 [cCSE-treated], and 389.9 ± 26.6 [hCSE-treated] mol/L/min; p = 0.002). Moreover, the levels of osteoblastic differentiation in untreated and hCSE-treated cells differed significantly (p < 0.05). In vivo assessment of the femoral midshaft cortical region revealed that both cCSE and hCSE administration significantly decreased bone mineral content 4 weeks after surgery compared with levels observed in untreated animals (107.0 ± 11.9 [untreated], 94.5 ± 13.0 [cCSE-treated], and 89.0 ± 10.1 mg/cm3 [hCSE-treated]; p = 0.049). Additionally, cCSE and hCSE-exposed femora had significantly lower bone volumes than unexposed femora. Biomechanical analyses showed that both cCSE and hCSE administration significantly decreased femoral maximum load and elastic modulus (p = 0.015 and 0.019). CONCLUSIONS HTP use impairs cell viability, osteoblastic differentiation, and bone fracture-healing at levels comparable with those associated with combustible cigarette use. CLINICAL RELEVANCE HTP use negatively affects bone fracture-healing to a degree similar to that of combustible cigarettes. Orthopaedic surgeons should recommend HTP smoking cessation to improve bone union.
Collapse
Affiliation(s)
- Kazuya Nishino
- Department of Orthopedics, Osaka City University Graduate School of Medicine, Osaka, Japan
| | | | | | | | | |
Collapse
|
10
|
Helena Macedo M, Baião A, Pinto S, Barros AS, Almeida H, Almeida A, das Neves J, Sarmento B. Mucus-producing 3D cell culture models. Adv Drug Deliv Rev 2021; 178:113993. [PMID: 34619286 DOI: 10.1016/j.addr.2021.113993] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/09/2021] [Revised: 08/23/2021] [Accepted: 09/29/2021] [Indexed: 10/20/2022]
Abstract
In vitro cell-based models have been used for a long time since they are normally easily obtained and have an advantageous cost-benefit. Besides, they can serve a variety of ends, from studying drug absorption and metabolism to disease modeling. However, some in vitro models are too simplistic, not accurately representing the living tissues. It has been shown, mainly in the last years, that fully mimicking a tissue composition and architecture can be paramount for cellular behavior and, consequently, for the outcomes of the studies using such models. Because of this, 3D in vitro cell models have been gaining much attention, since they are able to better replicate the in vivo environment. In this review we focus on 3D models that contain mucus-producing cells, as mucus can play a pivotal role in drug absorption. Being frequently overlooked, this viscous fluid can have an impact on drug delivery. Thus, the aim of this review is to understand to which extent can mucus affect mucosal drug delivery and to provide a state-of-the-art report on the existing 3D cell-based mucus models.
Collapse
|
11
|
In Vitro Ciliotoxicity and Cytotoxicity Testing of Repeated Chronic Exposure to Topical Nasal Formulations for Safety Studies. Pharmaceutics 2021; 13:pharmaceutics13111750. [PMID: 34834166 PMCID: PMC8618987 DOI: 10.3390/pharmaceutics13111750] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/26/2021] [Revised: 10/11/2021] [Accepted: 10/15/2021] [Indexed: 11/17/2022] Open
Abstract
Certain active drugs and excipients of nasal formulations may impair ciliary function and mucociliary clearance. The ciliary beat frequency (CBF) is a key parameter for determining mucociliary clearance rate, and in vitro assessments of CBF have proven to be accurate and reproducible. Since topical nasal formulations are applied with repeated doses, it is essential to elucidate their chronic, as opposed to acute, effect on mucociliary clearance and nasal mucosa. The aim of this study was to assess for the first time the ciliotoxicity and cytotoxicity of nasal sprays intended for chronic treatment (with repeated doses) using a previously designed set-up for CBF measurements. For 2 weeks, the 3D nasal MucilAir™ in vitro models were treated daily with undiluted or clinically relevant doses of mometasone nasal spray, placebo nasal spray, culture medium, or they were untreated. We demonstrated a dose-dependent and time-dependent (cumulative) effect of the nasal sprays on ciliary activity and cytotoxicity using CBF measurements and ultrastructural analysis, respectively. Our results indicate that repeated administration of clinically relevant doses of mometasone nasal spray is safe for in vivo use, which is in good agreement with a previous clinical study. Overall, our study suggests that such in vitro assays have great potential for topical nasal drug screening.
Collapse
|
12
|
Iskandar AR, Kolli AR, Giralt A, Neau L, Fatarova M, Kondylis A, Torres LO, Majeed S, Merg C, Corciulo M, Trivedi K, Guedj E, Frentzel S, Calvino F, Guy PA, Ivanov NV, Peitsch MC, Hoeng J. Assessment of in vitro kinetics and biological impact of nebulized trehalose on human bronchial epithelium. Food Chem Toxicol 2021; 157:112577. [PMID: 34563633 DOI: 10.1016/j.fct.2021.112577] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/03/2021] [Revised: 08/16/2021] [Accepted: 09/18/2021] [Indexed: 11/26/2022]
Abstract
Trehalose is added in drug formulations to act as fillers or improve aerosolization performance. Its characteristics as a carrier molecule have been explored; however, the fate of trehalose in human airway tissues has not been thoroughly investigated. Here, we investigated the fate of nebulized trehalose using in vitro human air-liquid bronchial epithelial cultures. First, a tracing experiment was conducted using 13C12-trehalose; we measured trehalose distribution in different culture compartments (apical surface liquid, epithelial culture, and basal side medium) at various time points following acute exposure to 13C12-labeled trehalose. We found that 13C12-trehalose was metabolized into 13C6-glucose. The data was then used to model the kinetics of trehalose disappearance from the apical surface of bronchial cultures. Secondly, we evaluated the potential adverse effects of nebulized trehalose on the bronchial cultures after they were acutely exposed to nebulized trehalose up to a level just below its solubility limit (50 g/100 g water). We assessed the ciliary beating frequency and histological characteristics. We found that nebulized trehalose did not lead to marked alteration in ciliary beating frequency and morphology of the epithelial cultures. The in vitro testing approach used here may enable the early selection of excipients for future development of inhalation products.
Collapse
Affiliation(s)
- Anita R Iskandar
- Philip Morris International R&D, Philip Morris Products S.A., Quai Jeanrenaud 5, 2000, Neuchâtel, Switzerland.
| | - Aditya Reddy Kolli
- Philip Morris International R&D, Philip Morris Products S.A., Quai Jeanrenaud 5, 2000, Neuchâtel, Switzerland.
| | - Albert Giralt
- Philip Morris International R&D, Philip Morris Products S.A., Quai Jeanrenaud 5, 2000, Neuchâtel, Switzerland.
| | - Laurent Neau
- Philip Morris International R&D, Philip Morris Products S.A., Quai Jeanrenaud 5, 2000, Neuchâtel, Switzerland.
| | - Maria Fatarova
- Philip Morris International R&D, Philip Morris Products S.A., Quai Jeanrenaud 5, 2000, Neuchâtel, Switzerland.
| | - Athanasios Kondylis
- Philip Morris International R&D, Philip Morris Products S.A., Quai Jeanrenaud 5, 2000, Neuchâtel, Switzerland.
| | - Laura Ortega Torres
- Philip Morris International R&D, Philip Morris Products S.A., Quai Jeanrenaud 5, 2000, Neuchâtel, Switzerland.
| | - Shoaib Majeed
- Philip Morris International R&D, Philip Morris Products S.A., Quai Jeanrenaud 5, 2000, Neuchâtel, Switzerland.
| | - Celine Merg
- Philip Morris International R&D, Philip Morris Products S.A., Quai Jeanrenaud 5, 2000, Neuchâtel, Switzerland.
| | - Maica Corciulo
- Philip Morris International R&D, Philip Morris Products S.A., Quai Jeanrenaud 5, 2000, Neuchâtel, Switzerland.
| | - Keyur Trivedi
- Philip Morris International R&D, Philip Morris Products S.A., Quai Jeanrenaud 5, 2000, Neuchâtel, Switzerland.
| | - Emmanuel Guedj
- Philip Morris International R&D, Philip Morris Products S.A., Quai Jeanrenaud 5, 2000, Neuchâtel, Switzerland.
| | - Stefan Frentzel
- Philip Morris International R&D, Philip Morris Products S.A., Quai Jeanrenaud 5, 2000, Neuchâtel, Switzerland.
| | - Florian Calvino
- Philip Morris International R&D, Philip Morris Products S.A., Quai Jeanrenaud 5, 2000, Neuchâtel, Switzerland.
| | - Philippe Alexandre Guy
- Philip Morris International R&D, Philip Morris Products S.A., Quai Jeanrenaud 5, 2000, Neuchâtel, Switzerland.
| | - Nikolai V Ivanov
- Philip Morris International R&D, Philip Morris Products S.A., Quai Jeanrenaud 5, 2000, Neuchâtel, Switzerland.
| | - Manuel C Peitsch
- Philip Morris International R&D, Philip Morris Products S.A., Quai Jeanrenaud 5, 2000, Neuchâtel, Switzerland.
| | - Julia Hoeng
- Philip Morris International R&D, Philip Morris Products S.A., Quai Jeanrenaud 5, 2000, Neuchâtel, Switzerland.
| |
Collapse
|
13
|
Haswell LE, Smart D, Jaunky T, Baxter A, Santopietro S, Meredith S, Camacho OM, Breheny D, Thorne D, Gaca MD. The development of an in vitro 3D model of goblet cell hyperplasia using MUC5AC expression and repeated whole aerosol exposures. Toxicol Lett 2021; 347:45-57. [PMID: 33892128 DOI: 10.1016/j.toxlet.2021.04.012] [Citation(s) in RCA: 6] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/16/2020] [Revised: 02/17/2021] [Accepted: 04/13/2021] [Indexed: 11/16/2022]
Abstract
Goblet cell hyperplasia and overproduction of airway mucin are characteristic features of the lung epithelium of smokers and COPD patients. Tobacco heating products (THPs) are a potentially less risky alternative to combustible cigarettes, and through continued use solus THPs may reduce smoking-related disease risk. Using the MucilAir™ in vitro lung model, a 6-week feasibility study was conducted investigating the effect of repeated cigarette smoke (1R6F), THP aerosol and air exposure. Tissues were exposed to nicotine-matched whole aerosol doses 3 times/week. Endpoints assessed were dosimetry, tight-junction integrity, cilia beat frequency (CBF) and active area (AA), cytokine secretion and airway mucin MUC5AC expression. Comparison of incubator and air exposed controls indicated exposures did not have a significant effect on the transepithelial electrical resistance (TEER), CBF and AA of the tissues. Cytokine secretion indicated clear differences in secretion patterns in response to 1R6F and THP exposure. 1R6F exposure resulted in a significant decrease in the TEER and AA (p=0.000 and p=0.000, respectively), and an increase in MUC5AC positive cells (p=0.002). Repeated THP exposure did not result in a significant change in MUC5AC positive cells. This study demonstrates repeated cigarette smoke whole aerosol exposure can induce these morphological changes in vitro.
Collapse
Affiliation(s)
- Linsey E Haswell
- British American Tobacco, R&D, Southampton, Hampshire, SO15 8TL, UK.
| | - David Smart
- British American Tobacco, R&D, Southampton, Hampshire, SO15 8TL, UK
| | - Tomasz Jaunky
- British American Tobacco, R&D, Southampton, Hampshire, SO15 8TL, UK
| | - Andrew Baxter
- British American Tobacco, R&D, Southampton, Hampshire, SO15 8TL, UK
| | | | - Stuart Meredith
- British American Tobacco, R&D, Southampton, Hampshire, SO15 8TL, UK
| | - Oscar M Camacho
- British American Tobacco, R&D, Southampton, Hampshire, SO15 8TL, UK
| | - Damien Breheny
- British American Tobacco, R&D, Southampton, Hampshire, SO15 8TL, UK
| | - David Thorne
- British American Tobacco, R&D, Southampton, Hampshire, SO15 8TL, UK
| | - Marianna D Gaca
- British American Tobacco, R&D, Southampton, Hampshire, SO15 8TL, UK
| |
Collapse
|
14
|
Giralt A, Iskandar AR, Martin F, Moschini E, Serchi T, Kondylis A, Marescotti D, Leroy P, Ortega-Torres L, Majeed S, Merg C, Trivedi K, Guedj E, Frentzel S, Ivanov NV, Peitsch MC, Gutleb AC, Hoeng J. Comparison of the biological impact of aerosol of e-vapor device with MESH® technology and cigarette smoke on human bronchial and alveolar cultures. Toxicol Lett 2021; 337:98-110. [PMID: 33220401 DOI: 10.1016/j.toxlet.2020.11.006] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/25/2020] [Revised: 11/02/2020] [Accepted: 11/08/2020] [Indexed: 11/30/2022]
Abstract
Exposure to aerosol from electronic vapor (e-vapor) products has been suggested to result in less risk of harm to smokers than cigarette smoke (CS) exposure. Although many studies on e-vapor products have tested the effects of liquid formulations on cell cultures, few have evaluated the effects of aerosolized formulations. We examined the effects of acute exposure to the aerosol of an e-vapor device that uses the MESH® technology (IQOS® MESH, Philip Morris International) and to CS from the 3R4F reference cigarette on human organotypic bronchial epithelial culture and alveolar triculture models. In contrast to 3R4F CS exposure, exposure to the IQOS MESH aerosol (Classic Tobacco flavor) did not cause cytotoxicity in bronchial epithelial cultures or alveolar tricultures despite its greater concentrations of deposited nicotine (3- and 4-fold, respectively). CS exposure caused a marked decrease in the frequency and active area of ciliary beating in bronchial cultures, whereas IQOS MESH aerosol exposure did not. Global mRNA expression and secreted protein profiles revealed a significantly lower impact of IQOS MESH aerosol exposure than 3R4F CS exposure. Overall, our whole aerosol exposure study shows a clearly reduced impact of IQOS MESH aerosol relative to CS in bronchial and alveolar cultures, even at greater nicotine doses.
Collapse
Affiliation(s)
- Albert Giralt
- Philip Morris International R&D, Philip Morris Products S.A., Quai Jeanrenaud 5, 2000, Neuchâtel, Switzerland
| | - Anita R Iskandar
- Philip Morris International R&D, Philip Morris Products S.A., Quai Jeanrenaud 5, 2000, Neuchâtel, Switzerland.
| | - Florian Martin
- Philip Morris International R&D, Philip Morris Products S.A., Quai Jeanrenaud 5, 2000, Neuchâtel, Switzerland
| | - Elisa Moschini
- Department of Environmental Research and Innovation, Luxembourg Institute of Science and Technology, Luxembourg
| | - Tomasso Serchi
- Department of Environmental Research and Innovation, Luxembourg Institute of Science and Technology, Luxembourg
| | - Athanasios Kondylis
- Philip Morris International R&D, Philip Morris Products S.A., Quai Jeanrenaud 5, 2000, Neuchâtel, Switzerland
| | - Diego Marescotti
- Philip Morris International R&D, Philip Morris Products S.A., Quai Jeanrenaud 5, 2000, Neuchâtel, Switzerland
| | - Patrice Leroy
- Philip Morris International R&D, Philip Morris Products S.A., Quai Jeanrenaud 5, 2000, Neuchâtel, Switzerland
| | - Laura Ortega-Torres
- Philip Morris International R&D, Philip Morris Products S.A., Quai Jeanrenaud 5, 2000, Neuchâtel, Switzerland
| | - Shoaib Majeed
- Philip Morris International R&D, Philip Morris Products S.A., Quai Jeanrenaud 5, 2000, Neuchâtel, Switzerland
| | - Celine Merg
- Philip Morris International R&D, Philip Morris Products S.A., Quai Jeanrenaud 5, 2000, Neuchâtel, Switzerland
| | - Keyur Trivedi
- Philip Morris International R&D, Philip Morris Products S.A., Quai Jeanrenaud 5, 2000, Neuchâtel, Switzerland
| | - Emmanuel Guedj
- Philip Morris International R&D, Philip Morris Products S.A., Quai Jeanrenaud 5, 2000, Neuchâtel, Switzerland
| | - Stefan Frentzel
- Philip Morris International R&D, Philip Morris Products S.A., Quai Jeanrenaud 5, 2000, Neuchâtel, Switzerland
| | - Nikolai V Ivanov
- Philip Morris International R&D, Philip Morris Products S.A., Quai Jeanrenaud 5, 2000, Neuchâtel, Switzerland
| | - Manuel C Peitsch
- Philip Morris International R&D, Philip Morris Products S.A., Quai Jeanrenaud 5, 2000, Neuchâtel, Switzerland
| | - Arno C Gutleb
- Department of Environmental Research and Innovation, Luxembourg Institute of Science and Technology, Luxembourg
| | - Julia Hoeng
- Philip Morris International R&D, Philip Morris Products S.A., Quai Jeanrenaud 5, 2000, Neuchâtel, Switzerland
| |
Collapse
|
15
|
Talikka M, Belcastro V, Boué S, Marescotti D, Hoeng J, Peitsch MC. Applying Systems Toxicology Methods to Drug Safety. SYSTEMS MEDICINE 2021. [DOI: 10.1016/b978-0-12-801238-3.11522-3] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/26/2022] Open
|
16
|
Schlage WK, Titz B, Iskandar A, Poussin C, Van der Toorn M, Wong ET, Pratte P, Maeder S, Schaller JP, Pospisil P, Boue S, Vuillaume G, Leroy P, Martin F, Ivanov NV, Peitsch MC, Hoeng J. Comparing the preclinical risk profile of inhalable candidate and potential candidate modified risk tobacco products: A bridging use case. Toxicol Rep 2020; 7:1187-1206. [PMID: 32995294 PMCID: PMC7502378 DOI: 10.1016/j.toxrep.2020.09.004] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/23/2020] [Revised: 06/24/2020] [Accepted: 09/01/2020] [Indexed: 11/25/2022] Open
Abstract
Heated tobacco products tested for reduced exposure and reduced risk properties. Bridging opportunities for nonclinical results from two heated tobacco products. Similarly reduced impact on apical and molecular endpoints relative to cigarettes. Evidence evaluated along a “causal chain of events leading to disease” (CELSD). Representative assays along CELSD could support nonclinical substantial equivalence.
Cigarette smoking causes major preventable diseases, morbidity, and mortality worldwide. Smoking cessation and prevention of smoking initiation are the preferred means for reducing these risks. Less harmful tobacco products, termed modified-risk tobacco products (MRTP), are being developed as a potential alternative for current adult smokers who would otherwise continue smoking. According to a regulatory framework issued by the US Food and Drug Administration, a manufacturer must provide comprehensive scientific evidence that the product significantly reduces harm and the risk of tobacco-related diseases, in order to obtain marketing authorization for a new MRTP. For new tobacco products similar to an already approved predicate product, the FDA has foreseen a simplified procedure for assessing “substantial equivalence”. In this article, we present a use case that bridges the nonclinical evidence from previous studies demonstrating the relatively reduced harm potential of two heat-not-burn products based on different tobacco heating principles. The nonclinical evidence was collected along a “causal chain of events leading to disease” (CELSD) to systematically follow the consequences of reduced exposure to toxicants (relative to cigarette smoke) through increasing levels of biological complexity up to disease manifestation in animal models of human disease. This approach leverages the principles of systems biology and toxicology as a basis for further extrapolation to human studies. The experimental results demonstrate a similarly reduced impact of both products on apical and molecular endpoints, no novel effects not seen with cigarette smoke exposure, and an effect of switching from cigarettes to either MRTP that is comparable to that of complete smoking cessation. Ideally, a subset of representative assays from the presented sequence along the CELSD could be sufficient for predicting similarity or substantial equivalence in the nonclinical impact of novel products; this would require further validation, for which the present use case could serve as a starting point.
Collapse
Key Words
- BIF, biological impact factor
- CELSD, causal chain of events leading to disease
- CHTP, carbon heated tobacco product
- CS, cigarette smoke
- CVD, cardiovascular disease
- GVP, gas/vapor phase
- HPHC, harmful and potentially harmful constituents
- MRTP, modified risk tobacco product
- Modified risk tobacco product (MRTP)
- NPA, network perturbation amplitude
- PMI, Philip Morris International
- RBIF, relative BIF
- Substantial equivalence
- Systems toxicology
- THS, Tobacco Heating System
- TPM, total particulate matter
- Tobacco harm reduction
Collapse
Affiliation(s)
| | - Bjoern Titz
- PMI R&D, Philip Morris Products S.A., Quai Jeanrenaud 5, CH-2000, Neuchâtel, Switzerland
| | - Anita Iskandar
- PMI R&D, Philip Morris Products S.A., Quai Jeanrenaud 5, CH-2000, Neuchâtel, Switzerland
| | - Carine Poussin
- PMI R&D, Philip Morris Products S.A., Quai Jeanrenaud 5, CH-2000, Neuchâtel, Switzerland
| | - Marco Van der Toorn
- PMI R&D, Philip Morris Products S.A., Quai Jeanrenaud 5, CH-2000, Neuchâtel, Switzerland
| | - Ee Tsin Wong
- PMI R&D, Philip Morris International Research Laboratories Pte. Ltd., Science Park II, Singapore
| | - Pascal Pratte
- PMI R&D, Philip Morris Products S.A., Quai Jeanrenaud 5, CH-2000, Neuchâtel, Switzerland
| | - Serge Maeder
- PMI R&D, Philip Morris Products S.A., Quai Jeanrenaud 5, CH-2000, Neuchâtel, Switzerland
| | - Jean-Pierre Schaller
- PMI R&D, Philip Morris Products S.A., Quai Jeanrenaud 5, CH-2000, Neuchâtel, Switzerland
| | - Pavel Pospisil
- PMI R&D, Philip Morris Products S.A., Quai Jeanrenaud 5, CH-2000, Neuchâtel, Switzerland
| | - Stephanie Boue
- PMI R&D, Philip Morris Products S.A., Quai Jeanrenaud 5, CH-2000, Neuchâtel, Switzerland
| | - Grégory Vuillaume
- PMI R&D, Philip Morris Products S.A., Quai Jeanrenaud 5, CH-2000, Neuchâtel, Switzerland
| | - Patrice Leroy
- PMI R&D, Philip Morris Products S.A., Quai Jeanrenaud 5, CH-2000, Neuchâtel, Switzerland
| | - Florian Martin
- PMI R&D, Philip Morris Products S.A., Quai Jeanrenaud 5, CH-2000, Neuchâtel, Switzerland
| | - Nikolai V Ivanov
- PMI R&D, Philip Morris Products S.A., Quai Jeanrenaud 5, CH-2000, Neuchâtel, Switzerland
| | - Manuel C Peitsch
- PMI R&D, Philip Morris Products S.A., Quai Jeanrenaud 5, CH-2000, Neuchâtel, Switzerland
| | - Julia Hoeng
- PMI R&D, Philip Morris Products S.A., Quai Jeanrenaud 5, CH-2000, Neuchâtel, Switzerland
| |
Collapse
|
17
|
Sewer A, Zanetti F, Iskandar AR, Guedj E, Dulize R, Peric D, Bornand D, Mathis C, Martin F, Ivanov NV, Peitsch MC, Hoeng J. A meta-analysis of microRNAs expressed in human aerodigestive epithelial cultures and their role as potential biomarkers of exposure response to nicotine-containing products. Toxicol Rep 2020; 7:1282-1295. [PMID: 33014713 PMCID: PMC7522043 DOI: 10.1016/j.toxrep.2020.09.001] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/25/2020] [Revised: 08/24/2020] [Accepted: 09/01/2020] [Indexed: 11/03/2022] Open
Abstract
The expression of some microRNAs (miRNA) is modulated in response to cigarette smoke (CS), which is a leading cause of major preventable diseases. However, whether miRNA expression is also modulated by the aerosol/extract from potentially reduced-risk products is not well studied. The present work is a meta-analysis of 12 in vitro studies in human organotypic epithelial cultures of the aerodigestive tract (buccal, gingival, bronchial, nasal, and small airway epithelia). These studies compared the effects of exposure to aerosols from electronic vapor (e-vapor) products and heated tobacco products, and to extracts from Swedish snus products (in the present work, will be referred to as reduced-risk products [RRPs]) on miRNA expression with the effects of exposure to CS or its total particulate matter fraction. This meta-analysis evaluated 12 datasets of a total of 736 detected miRNAs and 2775 exposed culture inserts. The t-distributed stochastic neighbor embedding method was used to find similarities across the diversity of miRNA responses characterized by tissue type, exposure type, and product concentration. The CS-induced changes in miRNA expression in gingival cultures were close to those in buccal cultures; similarly, the alterations in miRNA expression in small airway, bronchial, and nasal tissues resembled each other. A supervised clustering was performed to identify miRNAs exhibiting particular response patterns. The analysis identified a set of miRNAs whose expression was altered in specific tissues upon exposure to CS (e.g., miR-125b-5p, miR-132-3p, miR-99a-5p, and 146a-5p). Finally, we investigated the impact of RRPs on miRNA expression in relation to that of CS by calculating the response ratio r between the RRP- and CS-induced alterations at an individual miRNA level, showing reduced alterations in miRNA expression following RRP exposure relative to CS exposure (94 % relative reduction). No specific miRNA response pattern indicating exposure to aerosols from heated tobacco products and e-vapor products, or extracts from Swedish snus was identifiable.
Collapse
Key Words
- 2D, two-dimensional
- AKT, protein kinase B
- ALI, air-liquid interface
- CHTP 1.2, Carbon Heated Tobacco Product 1.2
- COPD, chronic obstructive pulmonary disease
- CRP, CORESTA Reference Product
- CS, cigarette smoke and its TPM fraction
- FDA, Food & Drug Administration
- FDR, false discovery rate
- GCW, General Classic White
- HCI, Health Canada intense
- HTP, heated tobacco product
- Heated tobacco product
- IL-1β, interleukin 1β
- MMP-1, matrix metalloproteinase 1
- N/A, not applicable
- Organotypic aerodigestive culture
- RRP, reduced-risk product
- Systems toxicology
- THS 2.2, Tobacco Heating System 2.2
- TPM, total particulate matter
- Tobacco Heating System 2.2
- e-vapor
- e-vapor, electronic vapor
- mRNA, messenger RNA
- mTOR, mammalian target of rapamycin
- miRNA
- miRNA, microRNA
- t-SNE, t-distributed stochastic neighbor embedding
Collapse
Affiliation(s)
- Alain Sewer
- PMI R&D, Philip Morris Products S.A., Quai Jeanrenaud 5, CH-2000 Neuchâtel, Switzerland
| | - Filippo Zanetti
- PMI R&D, Philip Morris Products S.A., Quai Jeanrenaud 5, CH-2000 Neuchâtel, Switzerland
| | - Anita R Iskandar
- PMI R&D, Philip Morris Products S.A., Quai Jeanrenaud 5, CH-2000 Neuchâtel, Switzerland
| | - Emmanuel Guedj
- PMI R&D, Philip Morris Products S.A., Quai Jeanrenaud 5, CH-2000 Neuchâtel, Switzerland
| | - Remi Dulize
- PMI R&D, Philip Morris Products S.A., Quai Jeanrenaud 5, CH-2000 Neuchâtel, Switzerland
| | - Dariusz Peric
- PMI R&D, Philip Morris Products S.A., Quai Jeanrenaud 5, CH-2000 Neuchâtel, Switzerland
| | - David Bornand
- PMI R&D, Philip Morris Products S.A., Quai Jeanrenaud 5, CH-2000 Neuchâtel, Switzerland
| | - Carole Mathis
- PMI R&D, Philip Morris Products S.A., Quai Jeanrenaud 5, CH-2000 Neuchâtel, Switzerland
| | - Florian Martin
- PMI R&D, Philip Morris Products S.A., Quai Jeanrenaud 5, CH-2000 Neuchâtel, Switzerland
| | - Nikolai V Ivanov
- PMI R&D, Philip Morris Products S.A., Quai Jeanrenaud 5, CH-2000 Neuchâtel, Switzerland
| | - Manuel C Peitsch
- PMI R&D, Philip Morris Products S.A., Quai Jeanrenaud 5, CH-2000 Neuchâtel, Switzerland
| | - Julia Hoeng
- PMI R&D, Philip Morris Products S.A., Quai Jeanrenaud 5, CH-2000 Neuchâtel, Switzerland
| |
Collapse
|
18
|
Ciliary beat frequency of in vitro human nasal epithelium measured with the simple high-speed microscopy is applicable for safety studies of nasal drug formulations. Toxicol In Vitro 2020; 66:104865. [DOI: 10.1016/j.tiv.2020.104865] [Citation(s) in RCA: 9] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/26/2019] [Revised: 04/08/2020] [Accepted: 04/14/2020] [Indexed: 01/04/2023]
|
19
|
Marescotti D, Bovard D, Morelli M, Sandoz A, Luettich K, Frentzel S, Peitsch M, Hoeng J. In Vitro High-Content Imaging-Based Phenotypic Analysis of Bronchial 3D Organotypic Air-Liquid Interface Cultures. SLAS Technol 2020; 25:247-252. [PMID: 31971054 DOI: 10.1177/2472630319895473] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/01/2023]
Abstract
High-content imaging (HCI) is a powerful method for quantifying biological effects in vitro. Historically, HCI has been applied to adherent cells growing in monolayers. With the advent of confocal versions of HCI devices, researchers now have the option of performing analyses on 3D cell cultures. However, some obstacles remain in integrating the third dimension, such as limited light penetration and less sophisticated image analysis. Here, we report the development of an HCI technique for imaging human bronchial 3D organotypic air-liquid interface (ALI) cultures (hBR-ALI). In this method, we monitored differentiation status through HCI evaluation markers representative of ciliated epithelial cells and goblet cells (Muc5AC [mucin 5AC]). As a second use case for demonstrating the utility of this technique, we induced goblet cell hyperplasia in hBR-ALI by using interleukin (IL)-13. Our results demonstrate the utility of the HCI technique for imaging hBR-ALI grown on Transwell inserts. This technique may be expanded to other cell culture systems, such as skin epithelia and 3D intestinal systems.
Collapse
Affiliation(s)
| | - David Bovard
- PMI R&D, Philip Morris Products S.A., Neuchâtel, Switzerland
| | - Moran Morelli
- PMI R&D, Philip Morris Products S.A., Neuchâtel, Switzerland
| | - Antonin Sandoz
- PMI R&D, Philip Morris Products S.A., Neuchâtel, Switzerland
| | - Karsta Luettich
- PMI R&D, Philip Morris Products S.A., Neuchâtel, Switzerland
| | - Stefan Frentzel
- PMI R&D, Philip Morris Products S.A., Neuchâtel, Switzerland
| | - Manuel Peitsch
- PMI R&D, Philip Morris Products S.A., Neuchâtel, Switzerland
| | - Julia Hoeng
- PMI R&D, Philip Morris Products S.A., Neuchâtel, Switzerland
| |
Collapse
|
20
|
Iskandar AR, Zanetti F, Kondylis A, Martin F, Leroy P, Majeed S, Steiner S, Xiang Y, Ortega Torres L, Trivedi K, Guedj E, Merg C, Frentzel S, Ivanov NV, Doshi U, Lee KM, McKinney WJ, Peitsch MC, Hoeng J. A lower impact of an acute exposure to electronic cigarette aerosols than to cigarette smoke in human organotypic buccal and small airway cultures was demonstrated using systems toxicology assessment. Intern Emerg Med 2019; 14:863-883. [PMID: 30835057 PMCID: PMC6722047 DOI: 10.1007/s11739-019-02055-x] [Citation(s) in RCA: 16] [Impact Index Per Article: 3.2] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 09/28/2018] [Accepted: 02/12/2019] [Indexed: 12/11/2022]
Abstract
In the context of tobacco harm-reduction strategy, the potential reduced impact of electronic cigarette (EC) exposure should be evaluated relative to the impact of cigarette smoke exposure. We conducted a series of in vitro studies to compare the biological impact of an acute exposure to aerosols of "test mix" (flavors, nicotine, and humectants), "base" (nicotine and humectants), and "carrier" (humectants) formulations using MarkTen® EC devices with the impact of exposure to smoke of 3R4F reference cigarettes, at a matching puff number, using human organotypic air-liquid interface buccal and small airway cultures. We measured the concentrations of nicotine and carbonyls deposited in the exposure chamber after each exposure experiment. The deposited carbonyl concentrations were used as representative measures to assess the reduced exposure to potentially toxic volatile substances. We followed a systems toxicology approach whereby functional biological endpoints, such as histopathology and ciliary beating frequency, were complemented by multiplex and omics assays to measure secreted inflammatory proteins and whole-genome transcriptomes, respectively. Among the endpoints analyzed, the only parameters that showed a significant response to EC exposure were secretion of proteins and whole-genome transcriptomes. Based on the multiplex and omics analyzes, the cellular responses to EC aerosol exposure were tissue type-specific; however, those alterations were much smaller than those following cigarette smoke exposure, even when the EC aerosol exposure under the testing conditions resulted in a deposited nicotine concentration approximately 200 times that in saliva of EC users.
Collapse
Affiliation(s)
- Anita R Iskandar
- Philip Morris International R&D, Philip Morris Products S.A., Quai Jeanrenaud 5, 2000, Neuchâtel, Switzerland.
| | - Filippo Zanetti
- Philip Morris International R&D, Philip Morris Products S.A., Quai Jeanrenaud 5, 2000, Neuchâtel, Switzerland
| | - Athanasios Kondylis
- Philip Morris International R&D, Philip Morris Products S.A., Quai Jeanrenaud 5, 2000, Neuchâtel, Switzerland
| | - Florian Martin
- Philip Morris International R&D, Philip Morris Products S.A., Quai Jeanrenaud 5, 2000, Neuchâtel, Switzerland
| | - Patrice Leroy
- Philip Morris International R&D, Philip Morris Products S.A., Quai Jeanrenaud 5, 2000, Neuchâtel, Switzerland
| | - Shoaib Majeed
- Philip Morris International R&D, Philip Morris Products S.A., Quai Jeanrenaud 5, 2000, Neuchâtel, Switzerland
| | - Sandro Steiner
- Philip Morris International R&D, Philip Morris Products S.A., Quai Jeanrenaud 5, 2000, Neuchâtel, Switzerland
| | - Yang Xiang
- Philip Morris International R&D, Philip Morris Products S.A., Quai Jeanrenaud 5, 2000, Neuchâtel, Switzerland
| | - Laura Ortega Torres
- Philip Morris International R&D, Philip Morris Products S.A., Quai Jeanrenaud 5, 2000, Neuchâtel, Switzerland
| | - Keyur Trivedi
- Philip Morris International R&D, Philip Morris Products S.A., Quai Jeanrenaud 5, 2000, Neuchâtel, Switzerland
| | - Emmanuel Guedj
- Philip Morris International R&D, Philip Morris Products S.A., Quai Jeanrenaud 5, 2000, Neuchâtel, Switzerland
| | - Celine Merg
- Philip Morris International R&D, Philip Morris Products S.A., Quai Jeanrenaud 5, 2000, Neuchâtel, Switzerland
| | - Stefan Frentzel
- Philip Morris International R&D, Philip Morris Products S.A., Quai Jeanrenaud 5, 2000, Neuchâtel, Switzerland
| | - Nikolai V Ivanov
- Philip Morris International R&D, Philip Morris Products S.A., Quai Jeanrenaud 5, 2000, Neuchâtel, Switzerland
| | - Utkarsh Doshi
- Altria Client Services LLC, Richmond, VA, 23219, USA
| | | | | | - Manuel C Peitsch
- Philip Morris International R&D, Philip Morris Products S.A., Quai Jeanrenaud 5, 2000, Neuchâtel, Switzerland
| | - Julia Hoeng
- Philip Morris International R&D, Philip Morris Products S.A., Quai Jeanrenaud 5, 2000, Neuchâtel, Switzerland
| |
Collapse
|
21
|
Talikka M, Belcastro V, Gubian S, Martin F, Peitsch MC, Hoeng J. Systems toxicology meta-analysis—From aerosol exposure to nanotoxicology. CURRENT OPINION IN TOXICOLOGY 2019. [DOI: 10.1016/j.cotox.2019.03.010] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/08/2023]
|
22
|
Boué S, Schlage WK, Page D, Hoeng J, Peitsch MC. Toxicological assessment of Tobacco Heating System 2.2: Findings from an independent peer review. Regul Toxicol Pharmacol 2019; 104:115-127. [PMID: 30878573 DOI: 10.1016/j.yrtph.2019.03.007] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/20/2018] [Revised: 02/12/2019] [Accepted: 03/09/2019] [Indexed: 01/09/2023]
Abstract
Offering safer alternatives to cigarettes, such as e-cigarettes and heated tobacco products, to smokers who are not willing to quit could reduce the harm caused by smoking. Extensive and rigorous scientific studies are conducted to assess the relative risk of such potentially modified risk tobacco products compared with that of smoking cigarettes. In addition to the peer review of publications reporting individual studies, we aimed to gauge the plausibility of the evidence to the scientific community and appreciate likely necessary additions prior to regulatory submission. Therefore, we sponsored a two-tier peer review organized by an independent third party who identified, recruited, and managed 7 panels of 5-12 experts whose identity remains unknown to us. The reviewers had access to all publications and raw data from preclinical and clinical studies via a web portal. The reviewers were asked questions regarding study design, methods, quality of data, and interpretation of results to judge the validity of the conclusions regarding the relative effects of the Tobacco Heating System 2.2 compared with cigarettes. Once their conclusions were submitted, the experts had the opportunity to participate in an anonymized online debate with their fellow panel members. We present here the results obtained from this innovative peer review effort which revealed supportive or very supportive of the study methods and results, and support the robustness of the studies and validity of the conclusions.
Collapse
Affiliation(s)
- Stéphanie Boué
- PMI R&D, Philip Morris Products S.A., Quai Jeanrenaud 5, CH-2000, Neuchâtel, Switzerland.
| | - Walter K Schlage
- PMI R&D, Philip Morris Products S.A., Quai Jeanrenaud 5, CH-2000, Neuchâtel, Switzerland
| | - David Page
- PMI R&D, Philip Morris Products S.A., Quai Jeanrenaud 5, CH-2000, Neuchâtel, Switzerland
| | - Julia Hoeng
- PMI R&D, Philip Morris Products S.A., Quai Jeanrenaud 5, CH-2000, Neuchâtel, Switzerland
| | - Manuel C Peitsch
- PMI R&D, Philip Morris Products S.A., Quai Jeanrenaud 5, CH-2000, Neuchâtel, Switzerland
| |
Collapse
|
23
|
Queloz S, Etter JF. An online survey of users of tobacco vaporizers, reasons and modes of utilization, perceived advantages and perceived risks. BMC Public Health 2019; 19:642. [PMID: 31133009 PMCID: PMC6537171 DOI: 10.1186/s12889-019-6957-0] [Citation(s) in RCA: 11] [Impact Index Per Article: 2.2] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/28/2018] [Accepted: 05/08/2019] [Indexed: 12/29/2022] Open
Abstract
BACKGROUND Tobacco vaporizers heat tobacco without burning it, to produce an inhalable aerosol. Various models have recently appeared on the market, mostly manufactured by the tobacco industry, but few of the studies published on tobacco vaporizers are independent from the manufacturers. The goals of this study were to explore who uses tobacco vaporizers, how these products are used, reasons for utilization, perceived advantages and risks. METHODS Online questionnaire collected from October 2016 to January 2018 in self-selected visitors aged > 18 to an anti-addiction website. RESULTS We obtained 170 valid responses, of whom 104 were using tobacco vaporizers. For homogeneity, we included only the 102 users of the Brand 1 tobacco vaporizer in our analysis, as there were only two users of other vaporizers. Among these 102 vaporizer users, about half were current cigarette smokers (57%), the rest were former cigarette smokers. The median age was 41, and the median duration of utilization was 9 months. Most (88%) used the vaporizer daily, 8% were occasional users and 4% were past users. Among current smokers, 80% were currently trying to reduce their cigarette consumption and 29% were trying to quit. The vaporizer was used mainly to replace cigarettes (94%), because it was perceived to be less toxic than cigarettes (89%), to help stop smoking or to avoid starting smoking again (72%), or to reduce cigarette consumption (71%). Current smokers who were daily or occasional vaporizer users reported smoking a median of 8.0 cigarettes per day, compared with 20.0 per day before they started to use the vaporizer (p < .0001, Wilcoxon signed-rank test). CONCLUSIONS In this online sample of early adopters, Brand 1 was by far the most frequently used tobacco vaporizer. It was used by current or former smokers only, mainly to replace cigarettes, and satisfaction ratings were good. Users considered the tobacco vaporizer to be less toxic than cigarette smoke and perceived it to be helpful for reducing or stopping smoking.
Collapse
Affiliation(s)
- Sébastien Queloz
- Institute of Global Health, Faculty of Medicine, University of Geneva, Geneva, Switzerland
| | - Jean-François Etter
- Institute of Global Health, Faculty of Medicine, University of Geneva, Geneva, Switzerland
| |
Collapse
|
24
|
Assessment of a 72-hour repeated exposure to Swedish snus extract and total particulate matter from 3R4F cigarette smoke on gingival organotypic cultures. Food Chem Toxicol 2019; 125:252-270. [DOI: 10.1016/j.fct.2018.12.056] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/20/2018] [Revised: 12/11/2018] [Accepted: 12/30/2018] [Indexed: 12/14/2022]
|
25
|
Dautzenberg B, Dautzenberg MD. [Systematic analysis of the scientific literature on heated tobacco]. Rev Mal Respir 2019; 36:82-103. [PMID: 30429092 DOI: 10.1016/j.rmr.2018.10.010] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/29/2018] [Accepted: 10/26/2018] [Indexed: 10/27/2022]
Abstract
INTRODUCTION The tobacco industry (TI) reports that heated tobacco reduces risk of tobacco use and will replace cigarettes. An analysis of the scientific literature was conducted in order to enlighten professionals and decision-makers. METHOD After a Medline query in February 2018, a systematic analysis was conducted. RESULTS Of the 100 papers published in 2008-2018, 75 have authors affiliated or linked to TI. Emissions contain gases, droplets and solid particles, so are smokes. The main products are: THS2.2 (Iqos®) which heats mini-cigarettes at 340°C, the THP1.0 (Glo®) which heats at 240°C sticks delivering about half as much nicotine, Ploom® which uses reconstituted tobacco microcapsules heated at 180°C. Under the experimental conditions, there is a reduction of toxic emissions and biological effects, but the expected risk reduction is not demonstrated. Symptoms related to passive smoking are described. The 4 epidemiological articles report that heated tobacco is used in 10 to 45% of cases by non-smokers and demonstrate the effectiveness of TI promotion campaigns. Thus, the THS2.2 is more a gateway to smoking (20%) than an exit door (11%); moreover, it is not expected risk reduction among the 69% who are mixed users. CONCLUSIONS While reducing emissions is documented, reducing the risk to the smoker who switches to heated-tobacco remains to be demonstrated. On the other hand, the worsening of the global tobacco risk related to the promotion of the products by the TI is anticipated, justifying that the authorities take the appropriate measures to control the promotion of heated tobacco.
Collapse
Affiliation(s)
- B Dautzenberg
- Service de pharmacologie, Pitié-Salpêtrière, AP-HP, 75013 Paris, France; Consultation de médecine, hôpital Marmottan, 75017 Paris, France; Consultation de tabacologie, institut Arthur-Vernes, 75006 Paris, France; Paris sans tabac, 14, avenue Bosquet, 75007 Paris, France.
| | | |
Collapse
|
26
|
Qiu L, Zhou W, Tan H, Tang X, Wang Y, Ma Z, Gao Y. Rethinking and new perspectives on cardiotoxicity of traditional Chinese medicine. Toxicol Res (Camb) 2018. [DOI: 10.1039/c8tx00271a] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/21/2022] Open
Abstract
Abstract
Traditional Chinese Medicine (TCM) has been commonly used in clinical practice for thousands of years and has made enormous contributions to public health in China. However, the adverse effects on the cardiac system or TCM-induced cardiovascular diseases have emerged frequently in recent years, resulting in growing attention to the safety of TCM. Generally, TCM with adverse cardiac effects has typical therapeutic or toxic effects, which are based on specific material basis for efficacy/toxicity, specific clinical symptoms and toxic mechanisms. However, improper strategies adopted for research on the cardiotoxicity of TCM simply follow the basic principles of conventional toxicology and cause exaggerative or incorrect interpretations in the toxicity of TCM. In this review, we aim to present the classification and possible toxic mechanisms for TCM with cardiotoxicity based on the material basis for toxicity to rethink the existing problems in toxicity studies for TCM and provide new perspectives for research on the potential cardiotoxicity of TCM. We hope that this study can offer important theoretical support and scientific advice for the toxicity study and clinical rational use of TCM having cardiotoxicity.
Collapse
Affiliation(s)
- Lizhen Qiu
- Tianjin University of Traditional Chinese Medicine, Tianjin 301617, PR China
- Department of Pharmaceutical Sciences, Beijing Institute of Radiation Medicine, Beijing, 100850, China
| | - Wei Zhou
- Department of Pharmaceutical Sciences, Beijing Institute of Radiation Medicine, Beijing, 100850, China
| | - Hongling Tan
- Department of Pharmaceutical Sciences, Beijing Institute of Radiation Medicine, Beijing, 100850, China
| | - Xianglin Tang
- Department of Pharmaceutical Sciences, Beijing Institute of Radiation Medicine, Beijing, 100850, China
| | - Yuguang Wang
- Department of Pharmaceutical Sciences, Beijing Institute of Radiation Medicine, Beijing, 100850, China
| | - Zengchun Ma
- Department of Pharmaceutical Sciences, Beijing Institute of Radiation Medicine, Beijing, 100850, China
| | - Yue Gao
- Tianjin University of Traditional Chinese Medicine, Tianjin 301617, PR China
- Department of Pharmaceutical Sciences, Beijing Institute of Radiation Medicine, Beijing, 100850, China
| |
Collapse
|
27
|
Poussin C, Laurent A, Kondylis A, Marescotti D, van der Toorn M, Guedj E, Goedertier D, Acali S, Pak C, Dulize R, Baumer K, Peric D, Maluenda E, Bornand D, Suarez IG, Schlage WK, Ivanov NV, Peitsch MC, Hoeng J. In vitro systems toxicology-based assessment of the potential modified risk tobacco product CHTP 1.2 for vascular inflammation- and cytotoxicity-associated mechanisms promoting adhesion of monocytic cells to human coronary arterial endothelial cells. Food Chem Toxicol 2018; 120:390-406. [PMID: 30026091 DOI: 10.1016/j.fct.2018.07.025] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/24/2018] [Revised: 06/29/2018] [Accepted: 07/13/2018] [Indexed: 12/24/2022]
Abstract
Cigarette smoking causes cardiovascular diseases. Heating tobacco instead of burning it reduces the amount of toxic compounds in the aerosol and may exert a reduced impact on health compared with cigarette smoke. Aqueous extract from the aerosol of a potential modified risk tobacco product, the Carbon Heated Tobacco Product (CHTP) 1.2, was compared in vitro with aqueous extract from the smoke of a 3R4F reference cigarette for its impact on the adhesion of monocytic cells to artery endothelial cells. Human coronary artery endothelial cells (HCAEC) were treated for 4 h with conditioned media from human monocytic Mono Mac 6 (MM6) cells exposed to CHTP1.2 or 3R4F extracts for 2 h or directly with those extracts freshly generated. In vitro monocyte-endothelial cell adhesion was measured concomitantly with inflammatory, oxidative stress, cytotoxicity, and death markers. Furthermore, transcriptomics analyses enabled to quantify the level of perturbation in HCAECs, and provide biological interpretation for the underlying molecular changes following exposure to 3R4F or CHTP1.2 extract. Our systems toxicology study demonstrated that approximately 10-15-fold higher concentrations of the CHTP 1.2 aerosol extract were needed to elicit similar effects as the 3R4F smoke extract on cardiovascular disease-relevant inflammation and cytotoxicity-related mechanisms and markers investigated in vitro.
Collapse
Affiliation(s)
- Carine Poussin
- PMI R&D, Philip Morris Products S.A., Part of Philip Morris International Group of Companies, Quai Jeanrenaud 5, CH-2000 Neuchâtel, Switzerland.
| | - Alexandra Laurent
- PMI R&D, Philip Morris Products S.A., Part of Philip Morris International Group of Companies, Quai Jeanrenaud 5, CH-2000 Neuchâtel, Switzerland
| | - Athanasios Kondylis
- PMI R&D, Philip Morris Products S.A., Part of Philip Morris International Group of Companies, Quai Jeanrenaud 5, CH-2000 Neuchâtel, Switzerland
| | - Diego Marescotti
- PMI R&D, Philip Morris Products S.A., Part of Philip Morris International Group of Companies, Quai Jeanrenaud 5, CH-2000 Neuchâtel, Switzerland
| | - Marco van der Toorn
- PMI R&D, Philip Morris Products S.A., Part of Philip Morris International Group of Companies, Quai Jeanrenaud 5, CH-2000 Neuchâtel, Switzerland
| | - Emmanuel Guedj
- PMI R&D, Philip Morris Products S.A., Part of Philip Morris International Group of Companies, Quai Jeanrenaud 5, CH-2000 Neuchâtel, Switzerland
| | - Didier Goedertier
- PMI R&D, Philip Morris Products S.A., Part of Philip Morris International Group of Companies, Quai Jeanrenaud 5, CH-2000 Neuchâtel, Switzerland
| | - Stefano Acali
- PMI R&D, Philip Morris Products S.A., Part of Philip Morris International Group of Companies, Quai Jeanrenaud 5, CH-2000 Neuchâtel, Switzerland
| | - Claudius Pak
- PMI R&D, Philip Morris Products S.A., Part of Philip Morris International Group of Companies, Quai Jeanrenaud 5, CH-2000 Neuchâtel, Switzerland
| | - Rémi Dulize
- PMI R&D, Philip Morris Products S.A., Part of Philip Morris International Group of Companies, Quai Jeanrenaud 5, CH-2000 Neuchâtel, Switzerland
| | - Karine Baumer
- PMI R&D, Philip Morris Products S.A., Part of Philip Morris International Group of Companies, Quai Jeanrenaud 5, CH-2000 Neuchâtel, Switzerland
| | - Dariusz Peric
- PMI R&D, Philip Morris Products S.A., Part of Philip Morris International Group of Companies, Quai Jeanrenaud 5, CH-2000 Neuchâtel, Switzerland
| | - Elodie Maluenda
- PMI R&D, Philip Morris Products S.A., Part of Philip Morris International Group of Companies, Quai Jeanrenaud 5, CH-2000 Neuchâtel, Switzerland
| | - David Bornand
- PMI R&D, Philip Morris Products S.A., Part of Philip Morris International Group of Companies, Quai Jeanrenaud 5, CH-2000 Neuchâtel, Switzerland
| | - Ignacio Gonzalez Suarez
- PMI R&D, Philip Morris Products S.A., Part of Philip Morris International Group of Companies, Quai Jeanrenaud 5, CH-2000 Neuchâtel, Switzerland
| | - Walter K Schlage
- Biology Consultant, Max-Baermann-Str. 21, 51429 Bergisch Gladbach, Germany
| | - Nikolai V Ivanov
- PMI R&D, Philip Morris Products S.A., Part of Philip Morris International Group of Companies, Quai Jeanrenaud 5, CH-2000 Neuchâtel, Switzerland
| | - Manuel C Peitsch
- PMI R&D, Philip Morris Products S.A., Part of Philip Morris International Group of Companies, Quai Jeanrenaud 5, CH-2000 Neuchâtel, Switzerland
| | - Julia Hoeng
- PMI R&D, Philip Morris Products S.A., Part of Philip Morris International Group of Companies, Quai Jeanrenaud 5, CH-2000 Neuchâtel, Switzerland
| |
Collapse
|
28
|
Choukrallah MA, Sewer A, Talikka M, Sierro N, Peitsch MC, Hoeng J, Ivanov NV. Epigenomics in tobacco risk assessment: Opportunities for integrated new approaches. CURRENT OPINION IN TOXICOLOGY 2018. [DOI: 10.1016/j.cotox.2019.01.001] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/27/2022]
|
29
|
Lacroix G, Koch W, Ritter D, Gutleb AC, Larsen ST, Loret T, Zanetti F, Constant S, Chortarea S, Rothen-Rutishauser B, Hiemstra PS, Frejafon E, Hubert P, Gribaldo L, Kearns P, Aublant JM, Diabaté S, Weiss C, de Groot A, Kooter I. Air-Liquid Interface In Vitro Models for Respiratory Toxicology Research: Consensus Workshop and Recommendations. ACTA ACUST UNITED AC 2018; 4:91-106. [PMID: 32953944 PMCID: PMC7500038 DOI: 10.1089/aivt.2017.0034] [Citation(s) in RCA: 111] [Impact Index Per Article: 18.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/08/2023]
Abstract
In vitro air-liquid interface (ALI) cell culture models can potentially be used to assess inhalation toxicology endpoints and are usually considered, in terms of relevancy, between classic (i.e., submerged) in vitro models and animal-based models. In some situations that need to be clearly defined, ALI methods may represent a complement or an alternative option to in vivo experimentations or classic in vitro methods. However, it is clear that many different approaches exist and that only very limited validation studies have been carried out to date. This means comparison of data from different methods is difficult and available methods are currently not suitable for use in regulatory assessments. This is despite inhalation toxicology being a priority area for many governmental organizations. In this setting, a 1-day workshop on ALI in vitro models for respiratory toxicology research was organized in Paris in March 2016 to assess the situation and to discuss what might be possible in terms of validation studies. The workshop was attended by major parties in Europe and brought together more than 60 representatives from various academic, commercial, and regulatory organizations. Following plenary, oral, and poster presentations, an expert panel was convened to lead a discussion on possible approaches to validation studies for ALI inhalation models. A series of recommendations were made and the outcomes of the workshop are reported.
Collapse
Affiliation(s)
- Ghislaine Lacroix
- Chronic Risks Division, Institut National de l'Environnement Industriel et des RISques, Verneuil-en-Halatte, France
| | - Wolfgang Koch
- In Vitro und Mechanistische Toxikologie, Fraunhofer ITEM, Hannover, Germany
| | - Detlef Ritter
- In Vitro und Mechanistische Toxikologie, Fraunhofer ITEM, Hannover, Germany
| | - Arno C Gutleb
- Environmental Research and Innovation (ERIN) Department, Luxembourg Institute of Science and Technology, Esch-sur-Alzette, Luxembourg
| | - Søren Thor Larsen
- Inhalation Toxicology Group, National Research Centre for the Working Environment, Copenhagen, Denmark
| | - Thomas Loret
- Chronic Risks Division, Institut National de l'Environnement Industriel et des RISques, Verneuil-en-Halatte, France
| | - Filippo Zanetti
- Systems Toxicology Department, Philip Morris International R&D, Neuchâtel, Switzerland
| | | | - Savvina Chortarea
- BioNanomaterials, Adolphe Merkle Institute, University of Fribourg, Fribourg, Switzerland.,Laboratory for Materials-Biology Interactions, EMPA, Swiss Federal Laboratories for Materials, Science and Technology, St Gallen, Switzerland
| | | | - Pieter S Hiemstra
- Department of Pulmonology, Leiden University Medical Center, Leiden, The Netherlands
| | - Emeric Frejafon
- Chronic Risks Division, Institut National de l'Environnement Industriel et des RISques, Verneuil-en-Halatte, France
| | - Philippe Hubert
- Chronic Risks Division, Institut National de l'Environnement Industriel et des RISques, Verneuil-en-Halatte, France
| | - Laura Gribaldo
- Directorate F-Health, Consumers and Reference Materials Chemicals Safety and Alternative Methods Unit (F.3), EURL ECVAM, JRC, Ispra, Italy
| | - Peter Kearns
- Environment, Health and Safety Division, OECD, Paris, France
| | - Jean-Marc Aublant
- European Affairs and Standardization, Laboratoire National de Métrologie et d'Essais, Paris, France
| | - Silvia Diabaté
- Institute of Toxicology and Genetics, Karlsruhe Institute of Technology, Karlsruhe, Germany
| | - Carsten Weiss
- Institute of Toxicology and Genetics, Karlsruhe Institute of Technology, Karlsruhe, Germany
| | - Antoinette de Groot
- Toxicological and Environmental Risk Assessment (TERA) Department, Solvay, Brussels, Belgium
| | - Ingeborg Kooter
- Department of Circular Environment and Environment (CEE), TNO, Utrecht, The Netherlands
| |
Collapse
|
30
|
Ishikawa S, Matsumura K, Kitamura N, Ishimori K, Takanami Y, Ito S. Application of a direct aerosol exposure system for the assessment of biological effects of cigarette smoke and novel tobacco product vapor on human bronchial epithelial cultures. Regul Toxicol Pharmacol 2018; 96:85-93. [PMID: 29730447 DOI: 10.1016/j.yrtph.2018.05.004] [Citation(s) in RCA: 18] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/16/2018] [Revised: 04/26/2018] [Accepted: 05/01/2018] [Indexed: 12/14/2022]
Abstract
Recent advancements in in vitro exposure systems and cell culture technology enable direct exposure to cigarette smoke (CS) of human organotypic bronchial epithelial cultures. MucilAir organotypic bronchial epithelial cultures were exposed, using a Vitrocell exposure system, to mainstream aerosols from the 3R4F cigarette or from a recently developed novel tobacco vapor product (NTV). The exposure aerosol dose was controlled by dilution flow and the number of products smoked; there were five exposure conditions for 3R4F smoke and three for NTV vapor. The amount of nicotine delivered to the tissues under each condition was analyzed and that of the total particulate matter (TPM) was estimated using nicotine data. The nicotine dose was similar for the two products at the highest dose, but the estimated TPM levels from the NTV were 3.7 times the levels from the 3R4F. Following 3R4F smoke exposure, a dose dependent increase was observed in cytotoxicity, cytokine secretion, and differential gene expression. However, no changes were detected in these endpoints following NTV vapor exposure, suggesting the biological effects of NTV vapor are lower than those of conventional combustible CS. Our study design, which includes collection of biological data and dosimetry data, is applicable to assessing novel tobacco products.
Collapse
Affiliation(s)
- Shinkichi Ishikawa
- Scientific Product Assessment Center, R&D Group, Japan Tobacco Inc., 6-2 Umegaoka, Aoba-ku, Yokohama, Kanagawa 227-8512, Japan.
| | - Kazushi Matsumura
- Scientific Product Assessment Center, R&D Group, Japan Tobacco Inc., 6-2 Umegaoka, Aoba-ku, Yokohama, Kanagawa 227-8512, Japan.
| | - Nobumasa Kitamura
- Scientific Product Assessment Center, R&D Group, Japan Tobacco Inc., 6-2 Umegaoka, Aoba-ku, Yokohama, Kanagawa 227-8512, Japan.
| | - Kanae Ishimori
- Scientific Product Assessment Center, R&D Group, Japan Tobacco Inc., 6-2 Umegaoka, Aoba-ku, Yokohama, Kanagawa 227-8512, Japan.
| | - Yuichiro Takanami
- Scientific Product Assessment Center, R&D Group, Japan Tobacco Inc., 6-2 Umegaoka, Aoba-ku, Yokohama, Kanagawa 227-8512, Japan.
| | - Shigeaki Ito
- Scientific Product Assessment Center, R&D Group, Japan Tobacco Inc., 6-2 Umegaoka, Aoba-ku, Yokohama, Kanagawa 227-8512, Japan.
| |
Collapse
|
31
|
Iskandar AR, Martin F, Leroy P, Schlage WK, Mathis C, Titz B, Kondylis A, Schneider T, Vuillaume G, Sewer A, Guedj E, Trivedi K, Elamin A, Frentzel S, Ivanov NV, Peitsch MC, Hoeng J. Comparative biological impacts of an aerosol from carbon-heated tobacco and smoke from cigarettes on human respiratory epithelial cultures: A systems toxicology assessment. Food Chem Toxicol 2018; 115:109-126. [PMID: 29501877 DOI: 10.1016/j.fct.2018.02.063] [Citation(s) in RCA: 17] [Impact Index Per Article: 2.8] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/30/2017] [Accepted: 02/27/2018] [Indexed: 02/02/2023]
Abstract
The biological impact of an aerosol of a potential modified-risk tobacco product, carbon heated tobacco product 1.2 (CHTP1.2), was comprehensively assessed for the first time in vitro using human small airway and nasal epithelial models following a systems toxicology approach. The potentially reduced effects of CHTP1.2 aerosol exposure were benchmarked against those of 3R4F cigarette smoke at similar nicotine concentrations. Experimental repetitions were conducted for which new batches of small airway and nasal cultures were exposed to CHTP1.2 aerosol or 3R4F smoke for 28 minutes. The biological impacts were determined based on a collection of endpoints including morphology, cytotoxicity, proinflammatory mediator profiles, cytochrome P450 1A1/1B1 activity, global mRNA and microRNA changes and proteome profiles. Alterations in mRNA expression were detected in cultures exposed to CHTP1.2 aerosol, without noticeable morphological changes and cytotoxicity, and minimal impact on proinflammatory mediator and proteome profiles. The changes linked to CHTP1.2 aerosol exposure, when observed, were transient. However, the impact of 3R4F smoke exposure persisted long post-exposure and greater than CHTP1.2 aerosol. Morphological changes were observed only in cultures exposed to 3R4F smoke. The lower biological effects of CHTP1.2 aerosol than 3R4F smoke exposure were observed similarly in both small airway and nasal epithelial cultures.
Collapse
Affiliation(s)
- Anita R Iskandar
- PMI R&D, Philip Morris Products S.A., Part of Philip Morris International group of companies, Quai Jeanrenaud 5, CH-2000 Neuchâtel, Switzerland.
| | - Florian Martin
- PMI R&D, Philip Morris Products S.A., Part of Philip Morris International group of companies, Quai Jeanrenaud 5, CH-2000 Neuchâtel, Switzerland
| | - Patrice Leroy
- PMI R&D, Philip Morris Products S.A., Part of Philip Morris International group of companies, Quai Jeanrenaud 5, CH-2000 Neuchâtel, Switzerland
| | - Walter K Schlage
- PMI R&D, Philip Morris Products S.A., Part of Philip Morris International group of companies, Quai Jeanrenaud 5, CH-2000 Neuchâtel, Switzerland
| | - Carole Mathis
- PMI R&D, Philip Morris Products S.A., Part of Philip Morris International group of companies, Quai Jeanrenaud 5, CH-2000 Neuchâtel, Switzerland
| | - Bjorn Titz
- PMI R&D, Philip Morris Products S.A., Part of Philip Morris International group of companies, Quai Jeanrenaud 5, CH-2000 Neuchâtel, Switzerland
| | - Athanasios Kondylis
- PMI R&D, Philip Morris Products S.A., Part of Philip Morris International group of companies, Quai Jeanrenaud 5, CH-2000 Neuchâtel, Switzerland
| | - Thomas Schneider
- PMI R&D, Philip Morris Products S.A., Part of Philip Morris International group of companies, Quai Jeanrenaud 5, CH-2000 Neuchâtel, Switzerland
| | - Grégory Vuillaume
- PMI R&D, Philip Morris Products S.A., Part of Philip Morris International group of companies, Quai Jeanrenaud 5, CH-2000 Neuchâtel, Switzerland
| | - Alain Sewer
- PMI R&D, Philip Morris Products S.A., Part of Philip Morris International group of companies, Quai Jeanrenaud 5, CH-2000 Neuchâtel, Switzerland
| | - Emmanuel Guedj
- PMI R&D, Philip Morris Products S.A., Part of Philip Morris International group of companies, Quai Jeanrenaud 5, CH-2000 Neuchâtel, Switzerland
| | - Keyur Trivedi
- PMI R&D, Philip Morris Products S.A., Part of Philip Morris International group of companies, Quai Jeanrenaud 5, CH-2000 Neuchâtel, Switzerland
| | - Ashraf Elamin
- PMI R&D, Philip Morris Products S.A., Part of Philip Morris International group of companies, Quai Jeanrenaud 5, CH-2000 Neuchâtel, Switzerland
| | - Stefan Frentzel
- PMI R&D, Philip Morris Products S.A., Part of Philip Morris International group of companies, Quai Jeanrenaud 5, CH-2000 Neuchâtel, Switzerland
| | - Nikolai V Ivanov
- PMI R&D, Philip Morris Products S.A., Part of Philip Morris International group of companies, Quai Jeanrenaud 5, CH-2000 Neuchâtel, Switzerland
| | - Manuel C Peitsch
- PMI R&D, Philip Morris Products S.A., Part of Philip Morris International group of companies, Quai Jeanrenaud 5, CH-2000 Neuchâtel, Switzerland
| | - Julia Hoeng
- PMI R&D, Philip Morris Products S.A., Part of Philip Morris International group of companies, Quai Jeanrenaud 5, CH-2000 Neuchâtel, Switzerland
| |
Collapse
|
32
|
Zanetti F, Sewer A, Scotti E, Titz B, Schlage WK, Leroy P, Kondylis A, Vuillaume G, Iskandar AR, Guedj E, Trivedi K, Schneider T, Elamin A, Martin F, Frentzel S, Ivanov NV, Peitsch MC, Hoeng J. Assessment of the impact of aerosol from a potential modified risk tobacco product compared with cigarette smoke on human organotypic oral epithelial cultures under different exposure regimens. Food Chem Toxicol 2018; 115:148-169. [PMID: 29505817 DOI: 10.1016/j.fct.2018.02.062] [Citation(s) in RCA: 23] [Impact Index Per Article: 3.8] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/29/2017] [Revised: 02/20/2018] [Accepted: 02/27/2018] [Indexed: 12/19/2022]
Abstract
Cigarette smoke (CS) is affecting considerably the oral mucosa. Heating, instead of burning, tobacco reduces consistently the amount of toxic compounds and may exert a lower impact on oral health than combusted cigarettes. The carbon-heated tobacco product 1.2 (CHTP1.2) is a potential modified risk tobacco product (MRTP) based on heat-not-burn technology. Using a systems toxicology assessment framework, we compared the effects of exposure to CHTP1.2 aerosol with those of CS from a reference cigarette (3R4F). Human organotypic cultures derived from buccal and gingival epithelia were exposed acutely (28-min) or repeatedly (28 min/day for 3 days), respectively, to two matching concentrations of CHTP1.2 aerosol or 3R4F CS, and a non-diluted (100%) CHTP1.2 aerosol. The results showed an absence of cytotoxicity, reduction in pathophysiological alterations, toxicological marker proteins, and inflammatory mediators following exposure to CHTP1.2 aerosol compared with 3R4F CS. Changes in mRNA and miRNA expression were linked by an integrative analysis approach, suggesting a regulatory role of miRNAs in several smoke/disease-relevant biological processes induced by 3R4F CS. The identification of mechanisms by which potential MRTPs can reduce the impact of tobacco use on biological systems is of great importance in understanding the molecular basis of the smoking harm reduction paradigm.
Collapse
Affiliation(s)
- Filippo Zanetti
- PMI R&D, Philip Morris Products S.A., Part of Philip Morris International Group of Companies, Quai Jeanrenaud 5, CH-2000 Neuchâtel, Switzerland.
| | - Alain Sewer
- PMI R&D, Philip Morris Products S.A., Part of Philip Morris International Group of Companies, Quai Jeanrenaud 5, CH-2000 Neuchâtel, Switzerland
| | - Elena Scotti
- PMI R&D, Philip Morris Products S.A., Part of Philip Morris International Group of Companies, Quai Jeanrenaud 5, CH-2000 Neuchâtel, Switzerland
| | - Bjoern Titz
- PMI R&D, Philip Morris Products S.A., Part of Philip Morris International Group of Companies, Quai Jeanrenaud 5, CH-2000 Neuchâtel, Switzerland
| | - Walter K Schlage
- Biology Consultant, Max-Baermann-Str. 21, 51429 Bergisch Gladbach, Germany
| | - Patrice Leroy
- PMI R&D, Philip Morris Products S.A., Part of Philip Morris International Group of Companies, Quai Jeanrenaud 5, CH-2000 Neuchâtel, Switzerland
| | - Athanasios Kondylis
- PMI R&D, Philip Morris Products S.A., Part of Philip Morris International Group of Companies, Quai Jeanrenaud 5, CH-2000 Neuchâtel, Switzerland
| | - Gregory Vuillaume
- PMI R&D, Philip Morris Products S.A., Part of Philip Morris International Group of Companies, Quai Jeanrenaud 5, CH-2000 Neuchâtel, Switzerland
| | - Anita R Iskandar
- PMI R&D, Philip Morris Products S.A., Part of Philip Morris International Group of Companies, Quai Jeanrenaud 5, CH-2000 Neuchâtel, Switzerland
| | - Emmanuel Guedj
- PMI R&D, Philip Morris Products S.A., Part of Philip Morris International Group of Companies, Quai Jeanrenaud 5, CH-2000 Neuchâtel, Switzerland
| | - Keyur Trivedi
- PMI R&D, Philip Morris Products S.A., Part of Philip Morris International Group of Companies, Quai Jeanrenaud 5, CH-2000 Neuchâtel, Switzerland
| | - Thomas Schneider
- PMI R&D, Philip Morris Products S.A., Part of Philip Morris International Group of Companies, Quai Jeanrenaud 5, CH-2000 Neuchâtel, Switzerland
| | - Ashraf Elamin
- PMI R&D, Philip Morris Products S.A., Part of Philip Morris International Group of Companies, Quai Jeanrenaud 5, CH-2000 Neuchâtel, Switzerland
| | - Florian Martin
- PMI R&D, Philip Morris Products S.A., Part of Philip Morris International Group of Companies, Quai Jeanrenaud 5, CH-2000 Neuchâtel, Switzerland
| | - Stefan Frentzel
- PMI R&D, Philip Morris Products S.A., Part of Philip Morris International Group of Companies, Quai Jeanrenaud 5, CH-2000 Neuchâtel, Switzerland
| | - Nikolai V Ivanov
- PMI R&D, Philip Morris Products S.A., Part of Philip Morris International Group of Companies, Quai Jeanrenaud 5, CH-2000 Neuchâtel, Switzerland
| | - Manuel C Peitsch
- PMI R&D, Philip Morris Products S.A., Part of Philip Morris International Group of Companies, Quai Jeanrenaud 5, CH-2000 Neuchâtel, Switzerland
| | - Julia Hoeng
- PMI R&D, Philip Morris Products S.A., Part of Philip Morris International Group of Companies, Quai Jeanrenaud 5, CH-2000 Neuchâtel, Switzerland
| |
Collapse
|
33
|
Haswell LE, Corke S, Verrastro I, Baxter A, Banerjee A, Adamson J, Jaunky T, Proctor C, Gaça M, Minet E. In vitro RNA-seq-based toxicogenomics assessment shows reduced biological effect of tobacco heating products when compared to cigarette smoke. Sci Rep 2018; 8:1145. [PMID: 29402904 PMCID: PMC5799303 DOI: 10.1038/s41598-018-19627-0] [Citation(s) in RCA: 27] [Impact Index Per Article: 4.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/11/2017] [Accepted: 01/05/2018] [Indexed: 12/11/2022] Open
Abstract
The battery of regulatory tests used to evaluate the risk of novel tobacco products such as heated tobacco products (THPs) presents some limitations including a bias towards the apical endpoint tested, and limited information on the mode of action. This is driving a paradigm shift to more holistic systems biology approaches. In this study, we used RNA-sequencing to compare the transcriptomic perturbations following acute exposure of a 3D airway tissue to the aerosols from two commercial THPs and a reference 3R4F cigarette. 2809 RNAs were differentially expressed for the 3R4F treatment and 115 and 2 RNAs for the two THPs (pFDR < 0.05, FC > 1.5), respectively. The relationship between the identified RNA features and gene ontologies were mapped showing a strong association with stress response, xenobiotics metabolism, and COPD-related terms for 3R4F. In contrast, fewer ontologies were found enriched for the THPs aerosols. "Response to wounding" was a common COPD-related term over-represented for the two THPs but at a reduced significance. Quantification of a cytokine panel post-exposure confirmed a pro-inflammatory effect of cigarette smoke but not for THPs. In conclusion, THPs have a reduced impact on gene expression compared to 3R4F.
Collapse
Affiliation(s)
- Linsey E Haswell
- British American Tobacco R&D Centre, Regents Park Road, Southampton, SO15 8TL, UK
| | - Sarah Corke
- British American Tobacco R&D Centre, Regents Park Road, Southampton, SO15 8TL, UK
| | - Ivan Verrastro
- British American Tobacco R&D Centre, Regents Park Road, Southampton, SO15 8TL, UK
| | - Andrew Baxter
- British American Tobacco R&D Centre, Regents Park Road, Southampton, SO15 8TL, UK
| | - Anisha Banerjee
- British American Tobacco R&D Centre, Regents Park Road, Southampton, SO15 8TL, UK
| | - Jason Adamson
- British American Tobacco R&D Centre, Regents Park Road, Southampton, SO15 8TL, UK
| | - Tomasz Jaunky
- British American Tobacco R&D Centre, Regents Park Road, Southampton, SO15 8TL, UK
| | - Christopher Proctor
- British American Tobacco R&D Centre, Regents Park Road, Southampton, SO15 8TL, UK
| | - Marianna Gaça
- British American Tobacco R&D Centre, Regents Park Road, Southampton, SO15 8TL, UK
| | - Emmanuel Minet
- British American Tobacco R&D Centre, Regents Park Road, Southampton, SO15 8TL, UK.
| |
Collapse
|
34
|
Iskandar AR, Martinez Y, Martin F, Schlage WK, Leroy P, Sewer A, Torres LO, Majeed S, Merg C, Trivedi K, Guedj E, Frentzel S, Mathis C, Ivanov NV, Peitsch MC, Hoeng J. Comparative effects of a candidate modified-risk tobacco product Aerosol and cigarette smoke on human organotypic small airway cultures: a systems toxicology approach. Toxicol Res (Camb) 2017; 6:930-946. [PMID: 30090554 PMCID: PMC6062162 DOI: 10.1039/c7tx00152e] [Citation(s) in RCA: 19] [Impact Index Per Article: 2.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/26/2017] [Accepted: 09/27/2017] [Indexed: 12/22/2022] Open
Abstract
Using an in vitro human small airway epithelium model, we assessed the biological impact of an aerosol from a candidate modified-risk tobacco product, the tobacco heating system (THS) 2.2, to investigate the potential reduced risk of THS2.2 aerosol exposure compared with cigarette smoke. Following the recommendations of the Institute of Medicine and the Tobacco Product Assessment Consortium, in which modified-risk tobacco products assessment should be performed in comparison with standard conventional products, the effects of the THS2.2 aerosol exposure on the small airway cultures were compared with those of 3R4F cigarette smoke. We used a systems toxicology approach whereby elucidation of toxic effects is derived not only from functional assay readouts but also from omics technologies. Cytotoxicity, ciliary beating function, secretion of pro-inflammatory mediators and histological assessment represented functional assays. The omics data included transcriptomic and miRNA profiles. Exposure-induced perturbations of causal biological networks were computed from the transcriptomic data. The results showed that THS2.2 aerosol exposure at the tested doses elicited lower cytotoxicity levels and lower changes in the secreted pro-inflammatory mediators than 3R4F smoke. Although THS2.2 exposure elicited alterations in the gene expression, a higher transcriptome-induced biological impact was observed following 3R4F smoke: The effects of THS2.2 aerosol exposure, if observed, were mostly transient and diminished more rapidly after exposure than those of 3R4F smoke. The study demonstrated that the systems toxicology approach can reveal changes at the cellular level that would be otherwise not detected from functional assays, thus increasing the sensitivity to detect potential toxicity of a treatment/exposure.
Collapse
Affiliation(s)
- Anita R Iskandar
- PMI R&D , Philip Morris Products S.A. (Part of Philip Morris International group of companies) , Quai Jeanrenaud 5 , CH-2000 Neuchâtel , Switzerland . ; ; Tel: +41 (58)242 2214
| | - Yannick Martinez
- PMI R&D , Philip Morris Products S.A. (Part of Philip Morris International group of companies) , Quai Jeanrenaud 5 , CH-2000 Neuchâtel , Switzerland . ; ; Tel: +41 (58)242 2214
| | - Florian Martin
- PMI R&D , Philip Morris Products S.A. (Part of Philip Morris International group of companies) , Quai Jeanrenaud 5 , CH-2000 Neuchâtel , Switzerland . ; ; Tel: +41 (58)242 2214
| | - Walter K Schlage
- Biology consultant , Max-Baermann-Str. 21 , 51429 Bergisch Gladbach , Germany
| | - Patrice Leroy
- PMI R&D , Philip Morris Products S.A. (Part of Philip Morris International group of companies) , Quai Jeanrenaud 5 , CH-2000 Neuchâtel , Switzerland . ; ; Tel: +41 (58)242 2214
| | - Alain Sewer
- PMI R&D , Philip Morris Products S.A. (Part of Philip Morris International group of companies) , Quai Jeanrenaud 5 , CH-2000 Neuchâtel , Switzerland . ; ; Tel: +41 (58)242 2214
| | - Laura Ortega Torres
- PMI R&D , Philip Morris Products S.A. (Part of Philip Morris International group of companies) , Quai Jeanrenaud 5 , CH-2000 Neuchâtel , Switzerland . ; ; Tel: +41 (58)242 2214
| | - Shoaib Majeed
- PMI R&D , Philip Morris Products S.A. (Part of Philip Morris International group of companies) , Quai Jeanrenaud 5 , CH-2000 Neuchâtel , Switzerland . ; ; Tel: +41 (58)242 2214
| | - Celine Merg
- PMI R&D , Philip Morris Products S.A. (Part of Philip Morris International group of companies) , Quai Jeanrenaud 5 , CH-2000 Neuchâtel , Switzerland . ; ; Tel: +41 (58)242 2214
| | - Keyur Trivedi
- PMI R&D , Philip Morris Products S.A. (Part of Philip Morris International group of companies) , Quai Jeanrenaud 5 , CH-2000 Neuchâtel , Switzerland . ; ; Tel: +41 (58)242 2214
| | - Emmanuel Guedj
- PMI R&D , Philip Morris Products S.A. (Part of Philip Morris International group of companies) , Quai Jeanrenaud 5 , CH-2000 Neuchâtel , Switzerland . ; ; Tel: +41 (58)242 2214
| | - Stefan Frentzel
- PMI R&D , Philip Morris Products S.A. (Part of Philip Morris International group of companies) , Quai Jeanrenaud 5 , CH-2000 Neuchâtel , Switzerland . ; ; Tel: +41 (58)242 2214
| | - Carole Mathis
- PMI R&D , Philip Morris Products S.A. (Part of Philip Morris International group of companies) , Quai Jeanrenaud 5 , CH-2000 Neuchâtel , Switzerland . ; ; Tel: +41 (58)242 2214
| | - Nikolai V Ivanov
- PMI R&D , Philip Morris Products S.A. (Part of Philip Morris International group of companies) , Quai Jeanrenaud 5 , CH-2000 Neuchâtel , Switzerland . ; ; Tel: +41 (58)242 2214
| | - Manuel C Peitsch
- PMI R&D , Philip Morris Products S.A. (Part of Philip Morris International group of companies) , Quai Jeanrenaud 5 , CH-2000 Neuchâtel , Switzerland . ; ; Tel: +41 (58)242 2214
| | - Julia Hoeng
- PMI R&D , Philip Morris Products S.A. (Part of Philip Morris International group of companies) , Quai Jeanrenaud 5 , CH-2000 Neuchâtel , Switzerland . ; ; Tel: +41 (58)242 2214
| |
Collapse
|
35
|
Assessment of tobacco heating product THP1.0. Part 5: In vitro dosimetric and cytotoxic assessment. Regul Toxicol Pharmacol 2017; 93:52-61. [PMID: 28987911 DOI: 10.1016/j.yrtph.2017.09.016] [Citation(s) in RCA: 36] [Impact Index Per Article: 5.1] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/19/2017] [Revised: 08/14/2017] [Accepted: 09/11/2017] [Indexed: 11/21/2022]
Abstract
Tobacco heating products (THPs) represent a subset of the next-generation nicotine and tobacco product category, in which tobacco is typically heated at temperatures of 250-350 °C, thereby avoiding many of the harmful combustion-related toxicant emissions of conventional cigarettes. In this study, we have assessed aerosol generation and cytotoxicity from two commercially available THPs, THP1.0 and THS, relative to tobacco smoke from 3R4F reference cigarettes, using an adapted Borgwaldt RM20S Smoking Machine. Quantification of nicotine in the exposed cell-culture media showed greater delivery of nicotine from both THPs than from the cigarette. Using Neutral Red Uptake assay, THPs demonstrated reduced in vitro cytotoxicity in H292 human bronchial epithelial cells as compared with 3R4F cigarette exposure at the air-liquid interface (p < 0.0001). Both THPs demonstrated a statistically similar reduction in biological response, with >87% viability relative to 3R4F at a common aerosol dilution (1:40, aerosol:air). A similar response was observed when plotted against nicotine; a statistical difference between 3R4F and THPs (p < 0.0001) and no difference between the THPs (p = 0.0186). This pre-clinical in vitro biological testing forms part of a larger package of data to help assess the safety and risk reduction potential of next-generation tobacco products relative to cigarettes, using a weight of evidence approach.
Collapse
|
36
|
Iskandar AR, Titz B, Sewer A, Leroy P, Schneider T, Zanetti F, Mathis C, Elamin A, Frentzel S, Schlage WK, Martin F, Ivanov NV, Peitsch MC, Hoeng J. Systems toxicology meta-analysis of in vitro assessment studies: biological impact of a candidate modified-risk tobacco product aerosol compared with cigarette smoke on human organotypic cultures of the aerodigestive tract. Toxicol Res (Camb) 2017; 6:631-653. [PMID: 30090531 PMCID: PMC6062142 DOI: 10.1039/c7tx00047b] [Citation(s) in RCA: 23] [Impact Index Per Article: 3.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/16/2017] [Accepted: 05/26/2017] [Indexed: 12/22/2022] Open
Abstract
Systems biology combines comprehensive molecular analyses with quantitative modeling to understand the characteristics of a biological system as a whole. Leveraging a similar approach, systems toxicology aims to decipher complex biological responses following exposures. This work reports a systems toxicology meta-analysis in the context of in vitro assessment of a candidate modified-risk tobacco product (MRTP) using three human organotypic cultures of the aerodigestive tract (buccal, bronchial, and nasal epithelia). Complementing a series of functional measures, a causal network enrichment analysis of transcriptomic data was used to compare quantitatively the biological impact of aerosol from the Tobacco Heating System (THS) 2.2, a candidate MRTP, with 3R4F cigarette smoke (CS) at similar nicotine concentrations. Lower toxicity was observed in all cultures following exposure to THS2.2 aerosol compared with 3R4F CS. Because of their morphological differences, a smaller exposure impact was observed in the buccal (stratified epithelium) compared with the bronchial and nasal (pseudostratified epithelium). However, the causal network enrichment approach supported a similar mechanistic impact of CS across the three cultures, including the impact on xenobiotic, oxidative stress, and inflammatory responses. At comparable nicotine concentrations, THS2.2 aerosol elicited reduced and more transient effects on these processes. To demonstrate the benefits of additional data modalities, we employed a newly established targeted mass-spectrometry marker panel to further confirm the reduced cellular stress responses elicited by THS2.2 aerosol compared with 3R4F CS in the nasal culture. Overall, this work demonstrates the applicability and robustness of the systems toxicology approach for in vitro inhalation toxicity assessment.
Collapse
Affiliation(s)
- A R Iskandar
- PMI R&D , Philip Morris Products S.A. (part of the Philip Morris International group of companies) , Quai Jeanrenaud 5 , CH-2000 Neuchâtel , Switzerland . ; ; Tel: +41 (58)242 2214
| | - B Titz
- PMI R&D , Philip Morris Products S.A. (part of the Philip Morris International group of companies) , Quai Jeanrenaud 5 , CH-2000 Neuchâtel , Switzerland . ; ; Tel: +41 (58)242 2214
| | - A Sewer
- PMI R&D , Philip Morris Products S.A. (part of the Philip Morris International group of companies) , Quai Jeanrenaud 5 , CH-2000 Neuchâtel , Switzerland . ; ; Tel: +41 (58)242 2214
| | - P Leroy
- PMI R&D , Philip Morris Products S.A. (part of the Philip Morris International group of companies) , Quai Jeanrenaud 5 , CH-2000 Neuchâtel , Switzerland . ; ; Tel: +41 (58)242 2214
| | - T Schneider
- PMI R&D , Philip Morris Products S.A. (part of the Philip Morris International group of companies) , Quai Jeanrenaud 5 , CH-2000 Neuchâtel , Switzerland . ; ; Tel: +41 (58)242 2214
| | - F Zanetti
- PMI R&D , Philip Morris Products S.A. (part of the Philip Morris International group of companies) , Quai Jeanrenaud 5 , CH-2000 Neuchâtel , Switzerland . ; ; Tel: +41 (58)242 2214
| | - C Mathis
- PMI R&D , Philip Morris Products S.A. (part of the Philip Morris International group of companies) , Quai Jeanrenaud 5 , CH-2000 Neuchâtel , Switzerland . ; ; Tel: +41 (58)242 2214
| | - A Elamin
- PMI R&D , Philip Morris Products S.A. (part of the Philip Morris International group of companies) , Quai Jeanrenaud 5 , CH-2000 Neuchâtel , Switzerland . ; ; Tel: +41 (58)242 2214
| | - S Frentzel
- PMI R&D , Philip Morris Products S.A. (part of the Philip Morris International group of companies) , Quai Jeanrenaud 5 , CH-2000 Neuchâtel , Switzerland . ; ; Tel: +41 (58)242 2214
| | - W K Schlage
- Biology consultant , Max-Baermann-Str. 21 , 51429 Bergisch Gladbach , Germany
| | - F Martin
- PMI R&D , Philip Morris Products S.A. (part of the Philip Morris International group of companies) , Quai Jeanrenaud 5 , CH-2000 Neuchâtel , Switzerland . ; ; Tel: +41 (58)242 2214
| | - N V Ivanov
- PMI R&D , Philip Morris Products S.A. (part of the Philip Morris International group of companies) , Quai Jeanrenaud 5 , CH-2000 Neuchâtel , Switzerland . ; ; Tel: +41 (58)242 2214
| | - M C Peitsch
- PMI R&D , Philip Morris Products S.A. (part of the Philip Morris International group of companies) , Quai Jeanrenaud 5 , CH-2000 Neuchâtel , Switzerland . ; ; Tel: +41 (58)242 2214
| | - J Hoeng
- PMI R&D , Philip Morris Products S.A. (part of the Philip Morris International group of companies) , Quai Jeanrenaud 5 , CH-2000 Neuchâtel , Switzerland . ; ; Tel: +41 (58)242 2214
| |
Collapse
|
37
|
Haswell LE, Baxter A, Banerjee A, Verrastro I, Mushonganono J, Adamson J, Thorne D, Gaça M, Minet E. Reduced biological effect of e-cigarette aerosol compared to cigarette smoke evaluated in vitro using normalized nicotine dose and RNA-seq-based toxicogenomics. Sci Rep 2017; 7:888. [PMID: 28420881 PMCID: PMC5429854 DOI: 10.1038/s41598-017-00852-y] [Citation(s) in RCA: 47] [Impact Index Per Article: 6.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/07/2016] [Accepted: 03/23/2017] [Indexed: 01/10/2023] Open
Abstract
Electronic cigarettes (e-cigarettes) use has increased globally and could potentially offer a lower risk alternative to cigarette smoking. Here, we assessed the transcriptional response of a primary 3D airway model acutely exposed to e-cigarette aerosol and cigarette (3R4F) smoke. Aerosols were generated with standard intense smoking regimens with careful consideration for dose by normalizing the exposures to nicotine. Two e-cigarette aerosol dilutions were tested for equivalent and higher nicotine delivery compared to 3R4F. RNA was extracted at 24 hrs and 48 hrs post exposure for RNA-seq. 873 and 205 RNAs were differentially expressed for 3R4F smoke at 24 hrs and 48 hrs using a pFDR < 0.01 and a [fold change] > 2 threshold. 113 RNAs were differentially expressed at the highest dose of e-cigarette aerosol using a looser threshold of pFDR < 0.05, 3 RNAs exceeded a fold change of 2. Geneset enrichment analysis revealed a clear response from lung cancer, inflammation, and fibrosis associated genes after 3R4F smoke exposure. Metabolic/biosynthetic processes, extracellular membrane, apoptosis, and hypoxia were identified for e-cigarette exposures, albeit with a lower confidence score. Based on equivalent or higher nicotine delivery, an acute exposure to e-cigarette aerosol had a reduced impact on gene expression compared to 3R4F smoke exposure in vitro.
Collapse
Affiliation(s)
- Linsey E Haswell
- British American Tobacco R&D Centre, Regents Park Road, Southampton, SO15 8TL, UK
| | - Andrew Baxter
- British American Tobacco R&D Centre, Regents Park Road, Southampton, SO15 8TL, UK
| | - Anisha Banerjee
- British American Tobacco R&D Centre, Regents Park Road, Southampton, SO15 8TL, UK
| | - Ivan Verrastro
- British American Tobacco R&D Centre, Regents Park Road, Southampton, SO15 8TL, UK
| | - Jessica Mushonganono
- British American Tobacco R&D Centre, Regents Park Road, Southampton, SO15 8TL, UK
| | - Jason Adamson
- British American Tobacco R&D Centre, Regents Park Road, Southampton, SO15 8TL, UK
| | - David Thorne
- British American Tobacco R&D Centre, Regents Park Road, Southampton, SO15 8TL, UK
| | - Marianna Gaça
- British American Tobacco R&D Centre, Regents Park Road, Southampton, SO15 8TL, UK
| | - Emmanuel Minet
- British American Tobacco R&D Centre, Regents Park Road, Southampton, SO15 8TL, UK.
| |
Collapse
|
38
|
Boué S, Exner T, Ghosh S, Belcastro V, Dokler J, Page D, Boda A, Bonjour F, Hardy B, Vanscheeuwijck P, Hoeng J, Peitsch M. Supporting evidence-based analysis for modified risk tobacco products through a toxicology data-sharing infrastructure. F1000Res 2017; 6:12. [PMID: 29123642 PMCID: PMC5657032 DOI: 10.12688/f1000research.10493.2] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Accepted: 10/25/2017] [Indexed: 01/24/2023] Open
Abstract
The US FDA defines modified risk tobacco products (MRTPs) as products that aim to reduce harm or the risk of tobacco-related disease associated with commercially marketed tobacco products. Establishing a product’s potential as an MRTP requires scientific substantiation including toxicity studies and measures of disease risk relative to those of cigarette smoking. Best practices encourage verification of the data from such studies through sharing and open standards. Building on the experience gained from the OpenTox project, a proof-of-concept database and website (
INTERVALS) has been developed to share results from both
in vivo inhalation studies and
in vitro studies conducted by Philip Morris International R&D to assess candidate MRTPs. As datasets are often generated by diverse methods and standards, they need to be traceable, curated, and the methods used well described so that knowledge can be gained using data science principles and tools. The data-management framework described here accounts for the latest standards of data sharing and research reproducibility. Curated data and methods descriptions have been prepared in ISA-Tab format and stored in a database accessible via a search portal on the INTERVALS website. The portal allows users to browse the data by study or mechanism (e.g., inflammation, oxidative stress) and obtain information relevant to study design, methods, and the most important results. Given the successful development of the initial infrastructure, the goal is to grow this initiative and establish a public repository for 21
st-century preclinical systems toxicology MRTP assessment data and results that supports open data principles.
Collapse
Affiliation(s)
- Stéphanie Boué
- PMI R&D, Philip Morris Products S.A., Neuchâtel, Switzerland
| | | | | | | | - Joh Dokler
- Douglas Connect GmbH, Zeiningen, Switzerland
| | - David Page
- PMI R&D, Philip Morris Products S.A., Neuchâtel, Switzerland
| | - Akash Boda
- PMI R&D, Philip Morris Products S.A., Neuchâtel, Switzerland
| | - Filipe Bonjour
- PMI R&D, Philip Morris Products S.A., Neuchâtel, Switzerland
| | - Barry Hardy
- Douglas Connect GmbH, Zeiningen, Switzerland
| | | | - Julia Hoeng
- PMI R&D, Philip Morris Products S.A., Neuchâtel, Switzerland
| | - Manuel Peitsch
- PMI R&D, Philip Morris Products S.A., Neuchâtel, Switzerland
| |
Collapse
|
39
|
Boué S, Exner T, Ghosh S, Belcastro V, Dokler J, Page D, Boda A, Bonjour F, Hardy B, Vanscheeuwijck P, Hoeng J, Peitsch M. Supporting evidence-based analysis for modified risk tobacco products through a toxicology data-sharing infrastructure. F1000Res 2017; 6:12. [PMID: 29123642 DOI: 10.12688/f1000research.10493.1] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Accepted: 01/03/2017] [Indexed: 12/11/2022] Open
Abstract
The US FDA defines modified risk tobacco products (MRTPs) as products that aim to reduce harm or the risk of tobacco-related disease associated with commercially marketed tobacco products. Establishing a product's potential as an MRTP requires scientific substantiation including toxicity studies and measures of disease risk relative to those of cigarette smoking. Best practices encourage verification of the data from such studies through sharing and open standards. Building on the experience gained from the OpenTox project, a proof-of-concept database and website ( INTERVALS) has been developed to share results from both in vivo inhalation studies and in vitro studies conducted by Philip Morris International R&D to assess candidate MRTPs. As datasets are often generated by diverse methods and standards, they need to be traceable, curated, and the methods used well described so that knowledge can be gained using data science principles and tools. The data-management framework described here accounts for the latest standards of data sharing and research reproducibility. Curated data and methods descriptions have been prepared in ISA-Tab format and stored in a database accessible via a search portal on the INTERVALS website. The portal allows users to browse the data by study or mechanism (e.g., inflammation, oxidative stress) and obtain information relevant to study design, methods, and the most important results. Given the successful development of the initial infrastructure, the goal is to grow this initiative and establish a public repository for 21 st-century preclinical systems toxicology MRTP assessment data and results that supports open data principles.
Collapse
Affiliation(s)
- Stéphanie Boué
- PMI R&D, Philip Morris Products S.A., Neuchâtel, Switzerland
| | | | | | | | - Joh Dokler
- Douglas Connect GmbH, Zeiningen, Switzerland
| | - David Page
- PMI R&D, Philip Morris Products S.A., Neuchâtel, Switzerland
| | - Akash Boda
- PMI R&D, Philip Morris Products S.A., Neuchâtel, Switzerland
| | - Filipe Bonjour
- PMI R&D, Philip Morris Products S.A., Neuchâtel, Switzerland
| | - Barry Hardy
- Douglas Connect GmbH, Zeiningen, Switzerland
| | | | - Julia Hoeng
- PMI R&D, Philip Morris Products S.A., Neuchâtel, Switzerland
| | - Manuel Peitsch
- PMI R&D, Philip Morris Products S.A., Neuchâtel, Switzerland
| |
Collapse
|