1
|
Cury J, Smets H, Bouzin C, Doguet P, Vanhoestenberghe A, Delbeke J, Tahry RE, Nonclercq A, Gorza SP. Optical birefringence changes in myelinated and unmyelinated nerves: A comparative study. JOURNAL OF BIOPHOTONICS 2022; 15:e202200028. [PMID: 35703916 DOI: 10.1002/jbio.202200028] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 02/03/2022] [Revised: 05/30/2022] [Accepted: 06/07/2022] [Indexed: 06/15/2023]
Abstract
The measurement of birefringence variations related to nerve activity is a promising label-free technique for sensing compound neural action potentials (CNAPs). While widely applied in crustaceans, little is known about its efficiency on mammal peripheral nerves. In this work, birefringence recordings to detect CNAPs, and Stokes parameters measurements were performed in rat and lobster nerves. While single-trial detection of nerve activity in crustaceans was achieved successfully, no optical signal was detected in rats, even after extensive signal filtering and averaging. The Stokes parameters showed that a high degree of polarization of light is maintained in lobster sample, whereas an almost complete light depolarization occurs in rat nerve. Our results indicate that depolarization itself is not sufficient to explain the absence of birefringence signals in rats. We hypothesize that this absence comes from the myelin sheets, which constraint the birefringence changes to only take place at the nodes of Ranvier.
Collapse
Affiliation(s)
- Joaquín Cury
- Opera-photonics, Université Libre de Bruxelles, Brussels, Belgium
- Bio-, Electro- and Mechanical Systems (BEAMS), Université Libre de Bruxelles, Brussels, Belgium
| | - Hugo Smets
- Bio-, Electro- and Mechanical Systems (BEAMS), Université Libre de Bruxelles, Brussels, Belgium
| | - Caroline Bouzin
- Université Catholique de Louvain, Institut de Recherche Expérimentale et Clinique (IREC), IREC Imaging Platform (2IP), Brussels, Belgium
| | | | - Anne Vanhoestenberghe
- Aspire Centre for Rehabilitation Engineering and Assistive Technology, University College of London, London, UK
| | - Jean Delbeke
- Department of Neurology, Institute of Neurosciences (IONS), Université Catholique de Louvain, Cliniques Universitaires Saint Luc, Brussels, Belgium
| | - Riëm El Tahry
- Department of Neurology, Institute of Neurosciences (IONS), Université Catholique de Louvain, Cliniques Universitaires Saint Luc, Brussels, Belgium
| | - Antoine Nonclercq
- Bio-, Electro- and Mechanical Systems (BEAMS), Université Libre de Bruxelles, Brussels, Belgium
| | | |
Collapse
|
2
|
Zhou Y, Liu E, Müller H, Cui B. Optical Electrophysiology: Toward the Goal of Label-Free Voltage Imaging. J Am Chem Soc 2021; 143:10482-10499. [PMID: 34191488 PMCID: PMC8514153 DOI: 10.1021/jacs.1c02960] [Citation(s) in RCA: 10] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/30/2022]
Abstract
Measuring and monitoring the electrical signals transmitted between neurons is key to understanding the communication between neurons that underlies human perception, information processing, and decision-making. While electrode-based electrophysiology has been the gold standard, optical electrophysiology has opened up a new area in the past decade. Voltage-dependent fluorescent reporters enable voltage imaging with high spatial resolution and flexibility to choose recording locations. However, they exhibit photobleaching as well as phototoxicity and may perturb the physiology of the cell. Label-free optical electrophysiology seeks to overcome these hurdles by detecting electrical activities optically, without the incorporation of exogenous fluorophores in cells. For example, electrochromic optical recording detects neuroelectrical signals via a voltage-dependent color change of extracellular materials, and interferometric optical recording monitors membrane deformations that accompany electrical activities. Label-free optical electrophysiology, however, is in an early stage, and often has limited sensitivity and temporal resolution. In this Perspective, we review the recent progress to overcome these hurdles. We hope this Perspective will inspire developments of label-free optical electrophysiology techniques with high recording sensitivity and temporal resolution in the near future.
Collapse
Affiliation(s)
- Yuecheng Zhou
- Department of Chemistry, Stanford University, S285 ChEM-H/Wu Tsai Neuroscience Research Complex, Stanford, California 94305, United States
| | - Erica Liu
- Department of Chemistry, Stanford University, S285 ChEM-H/Wu Tsai Neuroscience Research Complex, Stanford, California 94305, United States
| | - Holger Müller
- Department of Physics, University of California, 366 LeConte Hall, Berkeley, California 94720, United States
- Molecular Biophysics and Integrated Bioimaging, Lawrence Berkeley National Laboratory, Berkeley, California 94720, United States
| | - Bianxiao Cui
- Department of Chemistry, Stanford University, S285 ChEM-H/Wu Tsai Neuroscience Research Complex, Stanford, California 94305, United States
| |
Collapse
|
3
|
Sunil S, Evren Erdener S, Cheng X, Kura S, Tang J, Jiang J, Karrobi K, Kılıç K, Roblyer D, Boas DA. Stroke core revealed by tissue scattering using spatial frequency domain imaging. NEUROIMAGE-CLINICAL 2020; 29:102539. [PMID: 33385882 PMCID: PMC7779322 DOI: 10.1016/j.nicl.2020.102539] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 07/18/2020] [Revised: 12/14/2020] [Accepted: 12/15/2020] [Indexed: 12/26/2022]
Abstract
We present OCT and SFDI as methods to measure the spatial extent of stroke in mice. OCT was a reliable predictor of the stroke core in a photothrombosis stroke model. SFDI scattering coefficient spatially overlaps with OCT attenuation after stroke. Scattering increases following stroke reliably predict ischemic injury. SFDI provides a wide-field optical approach to map the stroke core.
Ischemic stroke leads to a reduction or complete loss of blood supply causing injury to brain tissue, which ultimately leads to behavioral impairment. Optical techniques are widely used to study the structural and functional changes that result as a consequence of ischemic stroke both in the acute and chronic phases of stroke recovery. It is currently a challenge to accurately estimate the spatial extent of the infarct without the use of histological parameters however, and in order to follow recovery mechanisms longitudinally at the mesoscopic scale it is essential to know the spatial extent of the stroke core. In this paper we first establish optical coherence tomography (OCT) as a reliable indicator of the stroke core by analyzing signal attenuation and spatially correlating it with the infarct, determined by staining with triphenyl-tetrazolium chloride (TTC). We then introduce spatial frequency domain imaging (SFDI) as a mesoscopic optical technique that can be used to accurately measure the infarct spatial extent by exploiting changes in optical scattering that occur as a consequence of ischemic stroke. Additionally, we follow the progression of ischemia through the acute and sub-acute phases of stroke recovery using both OCT and SFDI and show a consistently high spatial overlap in estimating infarct location. The use of SFDI in assessing infarct location will allow longitudinal studies targeted at following functional recovery mechanisms on a mesoscopic level without having to sacrifice the mouse acutely.
Collapse
Affiliation(s)
- Smrithi Sunil
- Department of Biomedical Engineering, Boston University, Boston, MA 02215, USA.
| | - Sefik Evren Erdener
- Department of Biomedical Engineering, Boston University, Boston, MA 02215, USA; Institute of Neurological Sciences and Psychiatry, Hacettepe University, Ankara, Turkey
| | - Xiaojun Cheng
- Department of Biomedical Engineering, Boston University, Boston, MA 02215, USA
| | - Sreekanth Kura
- Department of Biomedical Engineering, Boston University, Boston, MA 02215, USA
| | - Jianbo Tang
- Department of Biomedical Engineering, Boston University, Boston, MA 02215, USA
| | - John Jiang
- Department of Biomedical Engineering, Boston University, Boston, MA 02215, USA
| | - Kavon Karrobi
- Department of Biomedical Engineering, Boston University, Boston, MA 02215, USA
| | - Kıvılcım Kılıç
- Department of Biomedical Engineering, Boston University, Boston, MA 02215, USA
| | - Darren Roblyer
- Department of Biomedical Engineering, Boston University, Boston, MA 02215, USA; Department of Electrical and Computer Engineering, Boston University, Boston, MA 02215, USA
| | - David A Boas
- Department of Biomedical Engineering, Boston University, Boston, MA 02215, USA; Department of Electrical and Computer Engineering, Boston University, Boston, MA 02215, USA
| |
Collapse
|
4
|
Yang Y, Liu XW, Wang H, Yu H, Guan Y, Wang S, Tao N. Imaging Action Potential in Single Mammalian Neurons by Tracking the Accompanying Sub-Nanometer Mechanical Motion. ACS NANO 2018; 12:4186-4193. [PMID: 29570267 PMCID: PMC6141446 DOI: 10.1021/acsnano.8b00867] [Citation(s) in RCA: 31] [Impact Index Per Article: 4.4] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/21/2023]
Abstract
Action potentials in neurons have been studied traditionally by intracellular electrophysiological recordings and more recently by the fluorescence detection methods. Here we describe a label-free optical imaging method that can measure mechanical motion in single cells with a sub-nanometer detection limit. Using the method, we have observed sub-nanometer mechanical motion accompanying the action potential in single mammalian neurons by averaging the repeated action potential spikes. The shape and width of the transient displacement are similar to those of the electrically recorded action potential, but the amplitude varies from neuron to neuron, and from one region of a neuron to another, ranging from 0.2-0.4 nm. The work indicates that action potentials may be studied noninvasively in single mammalian neurons by label-free imaging of the accompanying sub-nanometer mechanical motion.
Collapse
Affiliation(s)
- Yunze Yang
- Center for Biosensors and Bioelectronics, Biodesign Institute, Arizona State University, Tempe, Arizona 85287, USA
| | - Xian-Wei Liu
- Center for Biosensors and Bioelectronics, Biodesign Institute, Arizona State University, Tempe, Arizona 85287, USA
- CAS Key Laboratory of Urban Pollutant Conversion, School of Chemistry and Materials Science, University of Science & Technology of China, Hefei 230026, China
| | - Hui Wang
- State Key Laboratory of Analytical Chemistry for Life Science, School of Chemistry and Chemical Engineering, Nanjing University, Nanjing 210093, China
| | - Hui Yu
- Center for Biosensors and Bioelectronics, Biodesign Institute, Arizona State University, Tempe, Arizona 85287, USA
| | - Yan Guan
- Center for Biosensors and Bioelectronics, Biodesign Institute, Arizona State University, Tempe, Arizona 85287, USA
- School of Electrical, Computer and Energy Engineering, Arizona State University, Tempe, Arizona 85287, USA
| | - Shaopeng Wang
- Center for Biosensors and Bioelectronics, Biodesign Institute, Arizona State University, Tempe, Arizona 85287, USA
| | - Nongjian Tao
- Center for Biosensors and Bioelectronics, Biodesign Institute, Arizona State University, Tempe, Arizona 85287, USA
- State Key Laboratory of Analytical Chemistry for Life Science, School of Chemistry and Chemical Engineering, Nanjing University, Nanjing 210093, China
| |
Collapse
|
5
|
Hiwaki O, Miyaguchi H. Noninvasive measurement of dynamic brain signals using light penetrating the brain. PLoS One 2018; 13:e0192095. [PMID: 29385211 PMCID: PMC5791992 DOI: 10.1371/journal.pone.0192095] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/25/2017] [Accepted: 01/16/2018] [Indexed: 11/17/2022] Open
Abstract
Conventional techniques for the noninvasive measurement of brain activity involve critical limitations in spatial or temporal resolution. Here, we propose the method for noninvasive brain function measurement with high spatiotemporal resolution using optical signals. We verified that diffused near-infrared light penetrating through the upper jaw and into the skull, which we term as optoencephalography (OEG), leads to the detection of dynamic brain signals that vary concurrently with the electrophysiological neural activity. We measured the OEG signals following the stimulation of the median nerve in common marmosets. The OEG signal response was tightly coupled with the electrophysiological response represented by the somatosensory evoked potential (SSEP). The OEG measurement is also shown to offer rather clear discrimination of brain signals.
Collapse
Affiliation(s)
- Osamu Hiwaki
- Graduate School of Information Sciences, Hiroshima City University, Hiroshima, Japan
| | - Hideki Miyaguchi
- Graduate School of Biomedical and Health Sciences, Hiroshima University, Hiroshima, Japan
| |
Collapse
|
6
|
Manoochehri M, Mahmoudzadeh M, Bourel-Ponchel E, Wallois F. Cortical light scattering during interictal epileptic spikes in frontal lobe epilepsy in children: A fast optical signal and electroencephalographic study. Epilepsia 2017; 58:2064-2072. [PMID: 29034451 DOI: 10.1111/epi.13926] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Accepted: 09/25/2017] [Indexed: 12/15/2022]
Abstract
OBJECTIVE Interictal epileptic spikes (IES) represent a signature of the transient synchronous and excessive discharge of a large ensemble of cortical heterogeneous neurons. Epilepsy cannot be reduced to a hypersynchronous activation of neurons whose functioning is impaired, resulting on electroencephalogram (EEG) in epileptic seizures or IES. The complex pathophysiological mechanisms require a global approach to the interactions between neural synaptic and nonsynaptic, vascular, and metabolic systems. In the present study, we focused on the interaction between synaptic and nonsynaptic mechanisms through the simultaneous noninvasive multimodal multiscale recording of high-density EEG (HD-EEG; synaptic) and fast optical signal (FOS; nonsynaptic), which evaluate rapid changes in light scattering related to changes in membrane configuration occurring during neuronal activation of IES. METHODS To evaluate changes in light scattering occurring around IES, three children with frontal IES were simultaneously recorded with HD-EEG and FOS. To evaluate change in synchronization, time-frequency representation analysis of the HD-EEG was performed simultaneously around the IES. To independently evaluate our multimodal method, a control experiment with somatosensory stimuli was designed and applied to five healthy volunteers. RESULTS Alternating increase-decrease-increase in optical signals occurred 200 ms before to 180 ms after the IES peak. These changes started before any changes in EEG signal. In addition, time-frequency domain EEG analysis revealed alternating decrease-increase-decrease in the EEG spectral power concomitantly with changes in the optical signal during IES. These results suggest a relationship between (de)synchronization and neuronal volume changes in frontal lobe epilepsy during IES. SIGNIFICANCE These changes in the neuronal environment around IES in frontal lobe epilepsy observed in children, as they have been in rats, raise new questions about the synaptic/nonsynaptic mechanisms that propel the neurons to hypersynchronization, as occurs during IES. We further demonstrate that this noninvasive multiscale multimodal approach is suitable for studying the pathophysiology of the IES in patients.
Collapse
Affiliation(s)
- Mana Manoochehri
- National Institute of Health and Medical Research Unit 1105, Research Group on Multimodal Analysis of Brain Function, University of Picardie Jules Verne, University Hospital Center South, Amiens, France
| | - Mahdi Mahmoudzadeh
- National Institute of Health and Medical Research Unit 1105, Research Group on Multimodal Analysis of Brain Function, University of Picardie Jules Verne, University Hospital Center South, Amiens, France
| | - Emilie Bourel-Ponchel
- National Institute of Health and Medical Research Unit 1105, Research Group on Multimodal Analysis of Brain Function, University of Picardie Jules Verne, University Hospital Center South, Amiens, France
| | - Fabrice Wallois
- National Institute of Health and Medical Research Unit 1105, Research Group on Multimodal Analysis of Brain Function, University of Picardie Jules Verne, University Hospital Center South, Amiens, France
| |
Collapse
|
7
|
Hua SH, Chen CP, Han P. Design of a simple non-destructive detection system using P-wave lasers for determining the soluble solids content of apples. APPLIED OPTICS 2017; 56:6235-6243. [PMID: 29047819 DOI: 10.1364/ao.56.006235] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 05/09/2017] [Accepted: 07/05/2017] [Indexed: 06/07/2023]
Abstract
The simple and nondestructive detection system studied in this work uses a near-infrared (NIR) detector and parallel-polarized (P-wave) NIR lasers to determine the soluble solids content (SSC) of apples. The P-wave NIR laser in this system is incident into the apple's pulp at the Brewster angle to minimize the interference caused by interfacial reflections. After the apple has been illuminated by four P-wave NIR lasers that correspond to the specified wavelengths of the SSC chemical bonds (880, 940, 980, and 1064 nm), the prediction of correlation (rp2) and the root-mean-square error for prediction (RMSEP) of the SSC are determined via partial least square regression analysis of the reflectance. Our results indicate that the use of P-wave lasers at the Brewster angle (as the angle of incidence) and the above specified wavelengths for the prediction set measurement of the SSC of apples obtained an rp2 of 0.88 and an RMSEP of 0.47°Brix. These rp2 are 6% higher, and the RMSEPs are 9% lower, than those obtained using non-polarized lasers.
Collapse
|
8
|
Zhao X, Thapa D, Wang B, Lu Y, Gai S, Yao X. Stimulus-evoked outer segment changes in rod photoreceptors. JOURNAL OF BIOMEDICAL OPTICS 2016; 21:65006. [PMID: 27334933 PMCID: PMC4917604 DOI: 10.1117/1.jbo.21.6.065006] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 03/23/2016] [Accepted: 06/01/2016] [Indexed: 05/21/2023]
Abstract
Rod-dominated transient retinal phototropism (TRP) has been recently observed in freshly isolated mouse and frog retinas. Comparative confocal microscopy and optical coherence tomography revealed that the TRP was predominantly elicited from the rod outer segment (OS). However, the biophysical mechanism of rod OS dynamics is still unknown. Mouse and frog retinal slices, which displayed a cross-section of retinal photoreceptors and other functional layers, were used to test the effect of light stimulation on rod OSs. Time-lapse microscopy revealed stimulus-evoked conformational changes of rod OSs. In the center of the stimulated region, the length of the rod OS shrunk, while in the peripheral region, the rod OS swung toward the center region. Our experimental observation and theoretical analysis suggest that the TRP may reflect unbalanced rod disc-shape changes due to localized visible light stimulation.
Collapse
Affiliation(s)
- Xiaohui Zhao
- Hebei University, College of Physics Science and Technology, Hebei Key Lab of Optic-Electronic Information Materials, Baoding 071002, China
- University of Illinois at Chicago, Department of Bioengineering, Chicago, Illinois 60607, United States
| | - Damber Thapa
- University of Illinois at Chicago, Department of Bioengineering, Chicago, Illinois 60607, United States
| | - Benquan Wang
- University of Illinois at Chicago, Department of Bioengineering, Chicago, Illinois 60607, United States
| | - Yiming Lu
- University of Illinois at Chicago, Department of Bioengineering, Chicago, Illinois 60607, United States
| | - Shaoyan Gai
- University of Illinois at Chicago, Department of Bioengineering, Chicago, Illinois 60607, United States
| | - Xincheng Yao
- Hebei University, College of Physics Science and Technology, Hebei Key Lab of Optic-Electronic Information Materials, Baoding 071002, China
- University of Illinois at Chicago, Department of Bioengineering, Chicago, Illinois 60607, United States
- University of Illinois at Chicago, Department of Ophthalmology and Visual Sciences, Chicago, Illinois 60612, United States
- Address all correspondence to: Xincheng Yao, E-mail:
| |
Collapse
|
9
|
Badreddine AH, Jordan T, Bigio IJ. Real-time imaging of action potentials in nerves using changes in birefringence. BIOMEDICAL OPTICS EXPRESS 2016; 7:1966-73. [PMID: 27231635 PMCID: PMC4871095 DOI: 10.1364/boe.7.001966] [Citation(s) in RCA: 7] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 02/10/2016] [Revised: 04/08/2016] [Accepted: 04/19/2016] [Indexed: 05/09/2023]
Abstract
Polarized light can be used to measure the electrical activity associated with action potential propagation in nerves, as manifested in simultaneous dynamic changes in their intrinsic optical birefringence. These signals may serve as a tool for minimally invasive neuroimaging in various types of neuroscience research, including the study of neuronal activation patterns with high spatiotemporal resolution. A fast linear photodiode array was used to image propagating action potentials in an excised portion of the lobster walking leg nerve. We show that the crossed-polarized signal (XPS) can be reliably imaged over a ≥2 cm span in our custom nerve chamber, by averaging multiple-stimulation signals, and also in single-scan real-time "movies". This demonstration paves the way toward utilizing changes in the optical birefringence to image more complex neuronal activity in nerve fibers and other organized neuronal tissue.
Collapse
Affiliation(s)
- Ali H. Badreddine
- Department of Biomedical Engineering, Boston University, Boston, MA 02215, USA
| | - Tomas Jordan
- Department of Biomedical Engineering, Boston University, Boston, MA 02215, USA
| | - Irving J. Bigio
- Department of Biomedical Engineering, Boston University, Boston, MA 02215, USA
- Department of Electrical & Computer Engineering, Boston University, Boston, MA 02215, USA
- Boston University Photonics Center, Boston University, Boston, MA 02215, USA
| |
Collapse
|
10
|
Badreddine AH, Schoener KJ, Bigio IJ. Elucidating the temporal dynamics of optical birefringence changes in crustacean nerves. BIOMEDICAL OPTICS EXPRESS 2015; 6:4165-78. [PMID: 26504663 PMCID: PMC4605072 DOI: 10.1364/boe.6.004165] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 08/10/2015] [Revised: 09/21/2015] [Accepted: 09/22/2015] [Indexed: 05/06/2023]
Abstract
Intrinsic optical properties, such as optical birefringence, may serve as a tool for minimally invasive neuroimaging methods with high spatiotemporal resolution to aid in the study of neuronal activation patterns. To facilitate imaging neuronal activity by sensing dynamic birefringence, temporal characteristics behind the signal must be better understood. We have developed a novel nerve chamber to investigate changes in birefringence at the stimulation site, and at distances ~4-28 mm from that site. Using crustacean nerves with either heterogeneous or homogeneous size distributions of axon diameters, we found that the gradual (slow) recovery of the crossed-polarized signal is not explained by the arrival times of action potentials in smaller axons. Through studying the effects of stimulating current and voltage pulses, we hypothesize that the recovery may be caused by a capacitive-like coupling between firing axons and adjacent tissue structures, and we report data consistent with this hypothesis. This study will aid in the utilization of action-potential-related changes in birefringence to study fast changes in neuronal network activity.
Collapse
Affiliation(s)
- Ali H. Badreddine
- Department of Biomedical Engineering, Boston University, Boston, MA 02215, USA
| | - Kurt J. Schoener
- Department of Biomedical Engineering, Boston University, Boston, MA 02215, USA
| | - Irving J. Bigio
- Department of Biomedical Engineering, Boston University, Boston, MA 02215, USA
- Department of Electrical & Computer Engineering, Boston University, Boston, MA 02215, USA
- Boston University Photonics Center, Boston University, Boston, MA 02215, USA
| |
Collapse
|
11
|
Yao X, Wang B. Intrinsic optical signal imaging of retinal physiology: a review. JOURNAL OF BIOMEDICAL OPTICS 2015; 20:090901. [PMID: 26405819 PMCID: PMC4689108 DOI: 10.1117/1.jbo.20.9.090901] [Citation(s) in RCA: 35] [Impact Index Per Article: 3.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 04/23/2015] [Accepted: 08/31/2015] [Indexed: 05/09/2023]
Abstract
Intrinsic optical signal (IOS) imaging promises to be a noninvasive method for high-resolution examination of retinal physiology, which can advance the study and diagnosis of eye diseases. While specialized optical instruments are desirable for functional IOS imaging of retinal physiology, in depth understanding of multiple IOS sources in the complex retinal neural network is essential for optimizing instrument designs. We provide a brief overview of IOS studies and relationships in rod outer segment suspensions, isolated retinas, and intact eyes. Recent developments of line-scan confocal and functional optical coherence tomography (OCT) instruments have allowed in vivo IOS mapping of photoreceptor physiology. Further improvements of the line-scan confocal and functional OCT systems may provide a feasible solution to pursue functional IOS mapping of human photoreceptors. Some interesting IOSs have already been detected in inner retinal layers, but better development of the IOS instruments and software algorithms is required to achieve optimal physiological assessment of inner retinal neurons.
Collapse
Affiliation(s)
- Xincheng Yao
- University of Illinois at Chicago, Department of Bioengineering, Chicago, Illinois 60607, United States
- University of Illinois at Chicago, Department of Ophthalmology and Visual Sciences, Chicago, Illinois 60612, United States
| | - Benquan Wang
- University of Illinois at Chicago, Department of Bioengineering, Chicago, Illinois 60607, United States
| |
Collapse
|
12
|
Yeh YJ, Black AJ, Landowne D, Akkin T. Optical coherence tomography for cross-sectional imaging of neural activity. NEUROPHOTONICS 2015. [PMID: 26217674 PMCID: PMC4509668 DOI: 10.1117/1.nph.2.3.035001] [Citation(s) in RCA: 7] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/09/2023]
Abstract
We report a functional optical coherence tomography cross-sectional scanner to detect neural activity using unmyelinated nerves dissected from squid. The nerves, unstained or stained with a voltage-sensitive dye, were imaged in a nerve chamber. Transient phase changes from backscattered light were detected during action potential propagation. The results show that the scanner can provide high spatiotemporal resolution cross-sectional images of neural activity ([Formula: see text]; [Formula: see text]; [Formula: see text] in [Formula: see text]). The advantage of this method compared to monitoring a single depth profile [Formula: see text] is a dramatic increase in the number of available sites that can be measured in two spatial dimensions [Formula: see text] with lateral scanning; therefore, the study demonstrates that two-dimensional monitoring of small-scale functional activity would also be feasible.
Collapse
Affiliation(s)
- Yi-Jou Yeh
- University of Minnesota, Department of Electrical and Computer Engineering, Minneapolis, Minnesota 55455, United States
- University of Minnesota, Department of Biomedical Engineering, 312 Church Street S.E., Minneapolis, Minnesota 55455, United States
| | - Adam J. Black
- University of Minnesota, Department of Biomedical Engineering, 312 Church Street S.E., Minneapolis, Minnesota 55455, United States
| | - David Landowne
- University of Miami, Department of Physiology and Biophysics, Miami, Florida 33101, United States
| | - Taner Akkin
- University of Minnesota, Department of Biomedical Engineering, 312 Church Street S.E., Minneapolis, Minnesota 55455, United States
- Address all correspondence to: Taner Akkin, E-mail:
| |
Collapse
|
13
|
Lu R, Zhang Q, Zhi Y, Yao X. A polarization-sensitive light field imager for multi-channel angular spectroscopy of light scattering in biological tissues. Quant Imaging Med Surg 2015; 5:1-8. [PMID: 25694947 DOI: 10.3978/j.issn.2223-4292.2014.11.01] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [Key Words] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/07/2014] [Accepted: 10/19/2014] [Indexed: 11/14/2022]
Abstract
BACKGROUND Angular spectroscopy of light scattering can be used for quantitative analysis of cellular and subcellular properties, and thus promises a noninvasive methodology for in vivo assessment cellular integrity to complement in vitro histological examination. Spatial information is essential for accurate identification of localized abnormalities. However, conventional angular spectroscopy systems only provide single-channel measurement, which suffers from poor spatial resolution or requires time-consuming scanning over extended area. The purpose of this study was to develop a multi-channel angular spectroscopy for light field imaging in biological tissues. MATERIALS AND METHODS A microlens array (MLA) (8×8) based light field imager for 64-channel angular spectroscopy was developed. A pair of crossed polarizers was employed for polarization-sensitive recording to enable quantitative measurement at high signal specificity and sensitivity. The polarization-sensitive light field imager enables rapid measurement of multiple sampling volumes simultaneously at 18 μm spatial-resolution and 3° angular-resolution. Comparative light field imaging and electrophysiological examination of freshly isolated and physiologically deteriorated lobster leg nerves have been conducted. RESULTS Two-dimensional (2D) polarization-sensitive scattering patterns of the fresh nerves were highly elliptical, while they gradually lost the ellipticity and became rotationally symmetric (i.e., circular) as the nerves physiologically deteriorated due to repeated electrical stimulations. Characterized parameters, i.e., the ellipticity and the scattering intensity, rendered spatially various characteristics such as different values and deteriorating rates. CONCLUSIONS The polarization-sensitive light field imager is able to provide multi-channel angular spectroscopy of light scattering with both spatial and angular resolutions. The light scattering properties of nerves are highly dependent on the orientation of nerves and their physiological status. Further development of polarization-sensitive multi-channel angular spectroscopy may promise a methodology for rapid and reliable identification of localized abnormalities in biological tissues.
Collapse
Affiliation(s)
- Rongwen Lu
- Department of Biomedical Engineering, University of Alabama at Birmingham, Birmingham, AL 35294, USA
| | - Qiuxiang Zhang
- Department of Biomedical Engineering, University of Alabama at Birmingham, Birmingham, AL 35294, USA
| | - Yanan Zhi
- Department of Biomedical Engineering, University of Alabama at Birmingham, Birmingham, AL 35294, USA
| | - Xincheng Yao
- Department of Biomedical Engineering, University of Alabama at Birmingham, Birmingham, AL 35294, USA
| |
Collapse
|
14
|
Wang B, Lu R, Zhang Q, Jiang Y, Yao X. En face optical coherence tomography of transient light response at photoreceptor outer segments in living frog eyecup. OPTICS LETTERS 2013; 38:4526-9. [PMID: 24322065 PMCID: PMC4428569 DOI: 10.1364/ol.38.004526] [Citation(s) in RCA: 10] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/22/2023]
Abstract
This study was designed to test the feasibility of en face mapping of the transient intrinsic optical signal (IOS) response at photoreceptor outer segments and to assess the effect of spatial resolution on functional IOS imaging of retinal photoreceptors. A line-scan optical coherence tomography (LS-OCT) was constructed to achieve depth-resolved functional IOS imaging of living frog eyecups. Rapid en face OCT revealed transient IOS almost immediately (<3 ms) after the onset of visible light flashes at photoreceptor outer segments. Quantitative analysis indicated that the IOS kinetics may reflect dynamics of G-protein binding and releasing in early phases of visual transduction, and high resolution is essential to differentiate positive and negative IOS changes in adjacent locations.
Collapse
Affiliation(s)
- Benquan Wang
- Department of Biomedical Engineering, University of Alabama at Birmingham, Birmingham, Alabama 35294, USA
| | - Rongwen Lu
- Department of Biomedical Engineering, University of Alabama at Birmingham, Birmingham, Alabama 35294, USA
| | - Qiuxiang Zhang
- Department of Biomedical Engineering, University of Alabama at Birmingham, Birmingham, Alabama 35294, USA
| | - Yuqiang Jiang
- Institute of Genetics and Developmental Biology, Chinese Academy of Sciences, Beijing 100101, China
| | - Xincheng Yao
- Department of Biomedical Engineering, University of Alabama at Birmingham, Birmingham, Alabama 35294, USA
- Vision Science Research Center, University of Alabama at Birmingham, Birmingham, Alabama 35294, USA
| |
Collapse
|
15
|
Oh S, Fang-Yen C, Choi W, Yaqoob Z, Fu D, Park Y, Dassari RR, Feld MS. Label-free imaging of membrane potential using membrane electromotility. Biophys J 2012; 103:11-8. [PMID: 22828327 DOI: 10.1016/j.bpj.2012.05.020] [Citation(s) in RCA: 46] [Impact Index Per Article: 3.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/12/2011] [Revised: 01/04/2012] [Accepted: 05/11/2012] [Indexed: 11/25/2022] Open
Abstract
Electrical activity may cause observable changes in a cell's structure in the absence of exogenous reporter molecules. In this work, we report a low-coherence interferometric microscopy technique that can detect an optical signal correlated with the membrane potential changes in individual mammalian cells without exogenous labels. By measuring milliradian-scale phase shifts in the transmitted light, we can detect changes in the cells' membrane potential. We find that the observed optical signals are due to membrane electromotility, which causes the cells to deform in response to the membrane potential changes. We demonstrate wide-field imaging of the propagation of electrical stimuli in gap-junction-coupled cell networks. Membrane electromotility-induced cell deformation may be useful as a reporter of electrical activity.
Collapse
Affiliation(s)
- Seungeun Oh
- G. R. Harrison Spectroscopy Laboratory, Massachusetts Institute of Technology, Cambridge, Massachusetts, USA.
| | | | | | | | | | | | | | | |
Collapse
|
16
|
Li YC, Luo JM, Lu RW, Liu KM, Levy AM, Yao XC. Dynamic intrinsic optical signal monitoring of electrically stimulated inner retinal neural response. JOURNAL OF MODERN OPTICS 2012; 59:10.1080/09500340.2012.687464. [PMID: 24403725 PMCID: PMC3882170 DOI: 10.1080/09500340.2012.687464] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/03/2023]
Abstract
Dynamic monitoring of stimulus-evoked inner neural response is important for functional validation of stimulation protocols of retinal prosthetic devices. In this paper, we demonstrate label-free intrinsic optical signal (IOS) imaging of electrically stimulated inner neural response in freshly isolated mouse retinas. While single-pulse stimulation evoked rapid IOS within 20 ms, pulse-train stimulation indicated that the fast IOS response can follow frequency stimulation up to at least 8 Hz. Fast IOS imaging promises a noninvasive method for high resolution examination of electrically evoked retinal response, without artifact contamination of electrical stimulus.
Collapse
Affiliation(s)
- Yi-Chao Li
- Department of Biomedical Engineering, University of Alabama at Birmingham, Birmingham, AL 35294, USA
| | - Jian-Min Luo
- Department of Ophthalmology and Visual Sciences, University of Nebraska Medical Center, Omaha, NE 68138, USA
| | - Rong-Wen Lu
- Department of Biomedical Engineering, University of Alabama at Birmingham, Birmingham, AL 35294, USA
| | - Kai-Mao Liu
- Department of Biochemistry & Molecular Genetics, University of Alabama at Birmingham, Birmingham, AL 35294, USA
| | - Alexander Miles Levy
- Department of Biomedical Engineering, University of Alabama at Birmingham, Birmingham, AL 35294, USA
| | - Xin-Cheng Yao
- Department of Biomedical Engineering, University of Alabama at Birmingham, Birmingham, AL 35294, USA
- Department of Vision Sciences, University of Alabama at Birmingham, Birmingham, AL 35294, USA
| |
Collapse
|
17
|
Lee J, Boas DA, Kim SJ. Multiphysics neuron model for cellular volume dynamics. IEEE Trans Biomed Eng 2011; 58:3000-3. [PMID: 21659016 DOI: 10.1109/tbme.2011.2159217] [Citation(s) in RCA: 11] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/10/2022]
Abstract
Even though cellular volume dynamics has been linked to cell apoptosis and intrinsic optical signals, there is no quantitative model for describing neuronal volume dynamics on the millisecond time scale. This study introduces a multiphysics neuron model, where the cell volume is a time-varying variable and multiple physical principles are combined to build governing equations. Using this model, we analyzed neuronal volume responses during excitation, which elucidated the variety of optical signals observed experimentally across the literature. Several physiological conditions were examined to investigate their effect on the pattern of volume response. In addition, we analyzed volume responses on a longer time scale with repetitive stimulation to study the characteristics of slow cell swelling. This multiscale analysis of the multiphysics model will provide not only a novel quantitative elucidation of physiologically important issues related with cellular volume dynamics but also a chance for further studies, such as the interesting possibility of inferring the balance of ion flux from plateau volume changes.
Collapse
Affiliation(s)
- Jonghwan Lee
- Martinos Center for Biomedical Imaging, Massachusetts General Hospital, Harvard Medical School, Charlestown, MA 02129, USA.
| | | | | |
Collapse
|
18
|
Lu RW, Zhang QX, Yao XC. Circular polarization intrinsic optical signal recording of stimulus-evoked neural activity. OPTICS LETTERS 2011; 36:1866-8. [PMID: 21593917 PMCID: PMC3197726 DOI: 10.1364/ol.36.001866] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/04/2023]
Abstract
Linear polarization intrinsic optical signal (LP-IOS) measurement can provide sensitive detection of neural activities in stimulus-activated neural tissues. However, the LP-IOS magnitude and signal-to-noise ratio (SNR) are highly correlated with the nerve orientation relative to the polarization plane of the incident light. Because of the complexity of orientation dependency, LP-IOS optimization and outcome interpretation are time consuming and complicated. In this study, we demonstrate the feasibility of circular polarization intrinsic optical signal (CP-IOS) measurement. Our theoretical modeling and experimental investigation indicate that CP-IOS magnitude and SNR are independent from the nerve orientation. Therefore, CP-IOS promises a practical method for polarization IOS imaging of complex neural systems.
Collapse
|
19
|
Abstract
Optical contrast based on elastic scattering interactions between light and matter can be used to probe cellular structure, cellular dynamics, and image tissue architecture. The quantitative nature and high sensitivity of light scattering signals to subtle alterations in tissue morphology, as well as the ability to visualize unstained tissue in vivo, has recently generated significant interest in optical-scatter-based biosensing and imaging. Here we review the fundamental methodologies used to acquire and interpret optical scatter data. We report on recent findings in this field and present current advances in optical scatter techniques and computational methods. Cellular and tissue data enabled by current advances in optical scatter spectroscopy and imaging stand to impact a variety of biomedical applications including clinical tissue diagnosis, in vivo imaging, drug discovery, and basic cell biology.
Collapse
Affiliation(s)
- Nada N. Boustany
- Corresponding Author: Rutgers University, Dept. of Biomedical Engineering, 599 Taylor Road, Piscataway, NJ 08854, Tel: (732) 445-4500 x6320,
| | - Stephen A. Boppart
- University of Illinois Urbana-Champaign, Depts. of Electrical and Computer Engineering, Bioengineering, Medicine, Beckman Institute for Advanced Science and Technology, 405 N. Mathews Avenue, Urbana, IL 61801, Tel: (217) 244-7479
| | - Vadim Backman
- Northwestern University, McCormick School of Engineering and Applied Sciences, Department of Biomedical Engineering, 2145 Sheridan Road, Evanston IL 60208, Tel: (847) 491-3536
| |
Collapse
|
20
|
Li YG, Zhang QX, Liu L, Amthor FR, Yao XC. High spatiotemporal resolution imaging of fast intrinsic optical signals activated by retinal flicker stimulation. OPTICS EXPRESS 2010; 18:7210-8. [PMID: 20389742 PMCID: PMC2927367 DOI: 10.1364/oe.18.007210] [Citation(s) in RCA: 15] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 12/16/2009] [Revised: 02/11/2010] [Accepted: 02/23/2010] [Indexed: 05/21/2023]
Abstract
High resolution monitoring of stimulus-evoked retinal neural activities is important for understanding retinal neural mechanisms, and can be a powerful tool for retinal disease diagnosis and treatment outcome evaluation. Fast intrinsic optical signals (IOSs), which have the time courses comparable to that of electrophysiological activities in the retina, hold the promise for high resolution imaging of retinal neural activities. However, application of fast IOS imaging has been hindered by the contamination of slow, high magnitude optical responses associated with transient hemodynamic and metabolic changes. In this paper we demonstrate the feasibility of separating fast retinal IOSs from slow optical responses by combining flicker stimulation and dynamic (temporal) differential image processing. A near infrared flood-illumination microscope equipped with a high-speed (1000 Hz) digital camera was used to conduct concurrent optical imaging and ERG measurement of isolated frog retinas. High spatiotemporal resolution imaging revealed that fast IOSs could follow flicker frequency up to at least 6 Hz. Comparable time courses of fast IOSs and ERG kinetics provide evidence that fast IOSs are originated from stimulus activated retinal neurons.
Collapse
Affiliation(s)
- Yang-Guo Li
- Department of Biomedical Engineering, University of Alabama at Birmingham, Birmingham, AL 35294,
USA
| | - Qiu-Xiang Zhang
- Department of Biomedical Engineering, University of Alabama at Birmingham, Birmingham, AL 35294,
USA
| | - Lei Liu
- Department of Optometry, University of Alabama at Birmingham, Birmingham, AL 35294,
USA
| | - Franklin R. Amthor
- Department of Psychology, University of Alabama at Birmingham, Birmingham, AL 35294,
USA
| | - Xin-Cheng Yao
- Department of Biomedical Engineering, University of Alabama at Birmingham, Birmingham, AL 35294,
USA
| |
Collapse
|
21
|
Lee J, Kim SJ. Spectrum measurement of fast optical signal of neural activity in brain tissue and its theoretical origin. Neuroimage 2010; 51:713-22. [PMID: 20211742 DOI: 10.1016/j.neuroimage.2010.02.076] [Citation(s) in RCA: 23] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/08/2009] [Revised: 02/21/2010] [Accepted: 02/28/2010] [Indexed: 10/19/2022] Open
Abstract
Functional brain imaging technologies have enabled recent advances in understanding human brain function. In particular, a noninvasive and fast optical technique will become one of the most promising tools for future studies. As a fundamental ex vivo study for the development of such a technique, this paper demonstrates the spectral measurement of fast optical changes associated with neural activity in bulk brain tissue. For this purpose, a high-speed confocal near-infrared spectrometer was built and used. The results verified that observed transient optical responses (tORs) are associated with neural activity by showing that the following: tORs were concurrent and correlated with local field potentials (LFPs); tORs disappeared following tetrodotoxin application; and tORs were reproducibly observed across preparations. In addition, the amplitude of tORs was statistically significantly larger in longer wavelengths (approximately 1200 nm). The time course of tORs, however, is quite different from that of LFPs. Since this difference implies that tORs may originate not directly from the electric potential variation but from other neurophysiological events accompanying excitation, this paper tested the hypothesis that tORs are attributed to transient cellular volume changes (tCVCs). With no previous dynamic equation to elucidate such different temporal dynamics of the optical responses, a novel mathematical neuron model to describe tCVCs was developed. This neuron model, along with finite-difference time-domain simulations, showed that tCVCs and tORs were similar in the temporal dynamics, order of magnitude, response direction, and detectability in the bulk tissue; thus supporting the hypothesis.
Collapse
Affiliation(s)
- Jonghwan Lee
- Graduate School of Neuroscience, Seoul National University, Seoul 151-742, South Korea.
| | | |
Collapse
|
22
|
Intrinsic optical signal imaging of retinal activation. Jpn J Ophthalmol 2009; 53:327-33. [PMID: 19763749 DOI: 10.1007/s10384-009-0685-4] [Citation(s) in RCA: 11] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/31/2008] [Accepted: 02/25/2009] [Indexed: 10/20/2022]
Abstract
Fast intrinsic optical signals (IOSs) correlated with stimulus-activated retinal responses are reviewed. Fast IOSs have a time course comparable to the stimulus-evoked electrophysiological kinetics of the retina, and thus promise a new methodology for high-resolution evaluation of the physiological health of the retina. However, practical application of fast IOSs for retinal study and diagnosis is challenging because of their low sensitivity and limited specificity. Using isolated amphibian retinas, a series of experiments to optimize and characterize fast IOSs has been conducted. Fast, high-resolution nearinfrared light imaging disclosed both positive (increasing) and negative (decreasing) optical responses in adjacent retinal areas, which satisfied spatial resolution essential to the differentiation of IOSs from opposite polarities. At the subcellular (approximately microm) level, fast IOSs often exceeded 5% DeltaI/I, where I is the dynamic optical change, and I is the background light intensity. Experiments with isolated frog retinas suggest that negative IOSs stem primarily from the photoreceptor layer, while positive IOSs come from inner retinal layers.
Collapse
|
23
|
Radhakrishnan H, Vanduffel W, Deng HP, Ekstrom L, Boas DA, Franceschini MA. Fast optical signal not detected in awake behaving monkeys. Neuroimage 2008; 45:410-9. [PMID: 19150500 DOI: 10.1016/j.neuroimage.2008.12.014] [Citation(s) in RCA: 37] [Impact Index Per Article: 2.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/18/2008] [Revised: 11/25/2008] [Accepted: 12/02/2008] [Indexed: 11/30/2022] Open
Abstract
While the ability of near-infrared spectroscopy (NIRS) to measure cerebral hemodynamic evoked responses (slow optical signal) is well established, its ability to measure non-invasively the 'fast optical signal' is still controversial. Here, we aim to determine the feasibility of performing NIRS measurements of the 'fast optical signal' or Event-Related Optical Signals (EROS) under optimal experimental conditions in awake behaving macaque monkeys. These monkeys were implanted with a 'recording well' to expose the dura above the primary visual cortex (V1). A custom-made optical probe was inserted and fixed into the well. The close proximity of the probe to the brain maximized the sensitivity to changes in optical properties in the cortex. Motion artifacts were minimized by physical restraint of the head. Full-field contrast-reversing checkerboard stimuli were presented to monkeys trained to perform a visual fixation task. In separate sessions, two NIRS systems (CW4 and ISS FD oximeter), which previously showed the ability to measure the fast signal in human, were used. In some sessions EEG was acquired simultaneously with the optical signal. The increased sensitivity to cortical optical changes with our experimental setup was quantified with 3D Monte Carlo simulations on a segmented MRI monkey head. Averages of thousands of stimuli in the same animal, or grand averages across the two animals and across repeated sessions, did not lead to detection of the fast optical signal using either amplitude or phase of the optical signal. Hemodynamic responses and visual evoked potentials were instead always detected with single trials or averages of a few stimuli. Based on these negative results, despite the optimal experimental conditions, we doubt the usefulness of non-invasive fast optical signal measurements with NIRS.
Collapse
Affiliation(s)
- Harsha Radhakrishnan
- Athinoula A. Martinos Center for Biomedical Imaging, Department of Radiology, Massachusetts General Hospital, 149, 13th Street, Rm 2277, Charlestown, MA 02129, USA.
| | | | | | | | | | | |
Collapse
|
24
|
Yao XC, Zhao YB. Optical dissection of stimulus-evoked retinal activation. OPTICS EXPRESS 2008; 16:12446-59. [PMID: 18711481 DOI: 10.1364/oe.16.012446] [Citation(s) in RCA: 17] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/05/2023]
Abstract
Better understanding of stimulus-evoked intrinsic optical signals (IOSs) in the retina promises new methodology for study and diagnosis of retinal function. Using a flood-illumination near infrared (NIR) light microscope equipped with high-speed CCD (80 Hz) and CMOS (1000 Hz) cameras, we validated depth-resolved enface imaging of fast IOSs in isolated retina of leopard frog. Both positive (increasing) and negative (decreasing) IOSs were observed at the photoreceptor and inner layers of the retina. The distribution of IOSs with opposite polarities showed a center-surround pattern. At the photoreceptor layer, negative IOSs dominated the center area illuminated by the stimulus light spot, while positive signals dominated the surrounding area. In contrast, at inner retinal layers, positive IOSs dominated the center area covered by the stimulus light spot, and negative IOSs were mainly observed in the surrounding area. Fast CMOS imaging disclosed rapid IOSs within 5 ms after the stimulus onset, and both ON and OFF optical responses were observed associated with a step light stimulus.
Collapse
Affiliation(s)
- Xin-Cheng Yao
- Department of Biomedical Engineering, University of Alabama at Birmingham, Birmingham, AL 35294, USA.
| | | |
Collapse
|
25
|
Foust AJ, Schei JL, Rojas MJ, Rector DM. In vitro and in vivo noise analysis for optical neural recording. JOURNAL OF BIOMEDICAL OPTICS 2008; 13:044038. [PMID: 19021365 PMCID: PMC2596884 DOI: 10.1117/1.2952295] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/16/2023]
Abstract
Laser diodes (LD) are commonly used for optical neural recordings in chronically recorded animals and humans, primarily due to their brightness and small size. However, noise introduced by LDs may counteract the benefits of brightness when compared to low-noise light-emitting diodes (LEDs). To understand noise sources in optical recordings, we systematically compared instrument and physiological noise profiles in two recording paradigms. A better understanding of noise sources can help improve optical recordings and make them more practical with fewer averages. We stimulated lobster nerves and a rat cortex, then compared the root mean square (RMS) noise and signal-to-noise ratios (SNRs) of data obtained with LED, superluminescent diode (SLD), and LD illumination for different numbers of averages. The LED data exhibited significantly higher SNRs in fewer averages than LD data in all recordings. In the absence of tissue, LED noise increased linearly with intensity, while LD noise increased sharply in the transition to lasing and settled to noise levels significantly higher than the LED's, suggesting that speckle noise contributed to the LD's higher noise and lower SNRs. Our data recommend low coherence and portable light sources for in vivo chronic neural recording applications.
Collapse
Affiliation(s)
- Amanda J. Foust
- Department of Veterinary and Comparative Anatomy, Pharmacology and Physiology, College of Veterinary Medicine, Washington State University, 205 Wegner Hall, Pullman, WA 99164, ph: 509−335−1587, FAX: 509−335−4650
| | - Jennifer L. Schei
- Department of Veterinary and Comparative Anatomy, Pharmacology and Physiology, College of Veterinary Medicine, Washington State University, 205 Wegner Hall, Pullman, WA 99164, ph: 509−335−1587, FAX: 509−335−4650
- Department of Physics and Astronomy, College of Sciences, Washington State University, Webster 646, Pullman, WA 99164
| | - Manuel J. Rojas
- Department of Veterinary and Comparative Anatomy, Pharmacology and Physiology, College of Veterinary Medicine, Washington State University, 205 Wegner Hall, Pullman, WA 99164, ph: 509−335−1587, FAX: 509−335−4650
| | - David M. Rector
- Department of Veterinary and Comparative Anatomy, Pharmacology and Physiology, College of Veterinary Medicine, Washington State University, 205 Wegner Hall, Pullman, WA 99164, ph: 509−335−1587, FAX: 509−335−4650
| |
Collapse
|
26
|
Schei JL, McCluskey MD, Foust AJ, Yao XC, Rector DM. Action potential propagation imaged with high temporal resolution near-infrared video microscopy and polarized light. Neuroimage 2008; 40:1034-43. [PMID: 18272402 DOI: 10.1016/j.neuroimage.2007.12.055] [Citation(s) in RCA: 17] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/21/2007] [Revised: 12/19/2007] [Accepted: 12/20/2007] [Indexed: 10/22/2022] Open
Abstract
To identify the neural constituents responsible for generating polarized light changes, we created spatially resolved movies of propagating action potentials from stimulated lobster leg nerves using both reflection and transmission imaging modalities. Changes in light polarization are associated with membrane depolarization and provide sub-millisecond temporal resolution. Typically, signals are detected using light transmitted through tissue; however, because we eventually would like to apply polarization techniques in-vivo, reflected light is required. In transmission mode, the optical signal was largest throughout the center of the nerve, suggesting that most of the optical signal arose from the inner nerve bundle. In reflection mode, polarization changes were largest near the edges, suggesting that most of the optical signal arose from the outer sheath. In support of these observations, an optical model of the tissue showed that the outer sheath is more reflective while the inner nerve bundle is more transmissive. In order to apply these techniques in-vivo, we must consider that brain tissue does not have a regular orientation of processes as in the lobster nerve. We tested the effect of randomizing cell orientation by tying the nerve in an overhand knot prior to imaging, producing polarization changes that can be imaged even without regular cell orientations.
Collapse
Affiliation(s)
- Jennifer L Schei
- Department of Physics and Astronomy, Washington State University, Pullman, WA 99164-2814, USA
| | | | | | | | | |
Collapse
|
27
|
Akkin T, Joo C, de Boer JF. Depth-resolved measurement of transient structural changes during action potential propagation. Biophys J 2007; 93:1347-53. [PMID: 17526590 PMCID: PMC1929037 DOI: 10.1529/biophysj.106.091298] [Citation(s) in RCA: 55] [Impact Index Per Article: 3.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/18/2022] Open
Abstract
We report noncontact optical measurement of fast transient structural changes in the crustacean nerve during action potential propagation without the need for exogenous chemicals or reflection coatings. The technique, spectral domain optical coherence tomography, provides real-time cross-sectional images of the nerve with micron-scale resolution to select a specific region for functional assessment and interferometric phase sensitivity for subnanometer-scale motion detection. Noncontact optical measurements demonstrate nanometer-scale transient movement on a 1-ms timescale associated with action potential propagation in crayfish and lobster nerves.
Collapse
Affiliation(s)
- Taner Akkin
- Harvard Medical School and Wellman Center for Photomedicine at Massachusetts General Hospital, Boston, Massachusetts 02114, USA.
| | | | | |
Collapse
|
28
|
McCluskey MD, Sable JJ, Foust AJ, Gratton G, Rector DM. Recording invertebrate nerve activation with modulated light changes. APPLIED OPTICS 2007; 46:1866-71. [PMID: 17356632 DOI: 10.1364/ao.46.001866] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/14/2023]
Abstract
Optical scattering techniques have the potential to provide noninvasive measurements of neural activity with good spatial and temporal resolution. We used the lobster nerve as a model system to investigate and record event-related optical signals with a modulated light source and heterodyne detection system. We observed changes in the transmitted birefringent light intensity, corresponding with electrophysiological measurements of the action potential. The photon delay was below the detection threshold, in part due to the small size of the nerve bundle. Our system allowed us to place an upper bound on the magnitude of the phase change of 0.01 degrees. The physiological stability of the preparation allows comprehensive characterization of biological and instrumentation noise sources for testing optical measurement systems.
Collapse
Affiliation(s)
- Matthew D McCluskey
- Department of Physics and Astronomy, Washington State University , Washington 99164-2814, USA.
| | | | | | | | | |
Collapse
|
29
|
Foust AJ, Rector DM. Optically teasing apart neural swelling and depolarization. Neuroscience 2007; 145:887-99. [PMID: 17303339 PMCID: PMC1888560 DOI: 10.1016/j.neuroscience.2006.12.068] [Citation(s) in RCA: 58] [Impact Index Per Article: 3.2] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/10/2006] [Revised: 12/19/2006] [Accepted: 12/20/2006] [Indexed: 11/26/2022]
Abstract
We measured birefringence, 90 degree scattered light, and voltage sensitive dye changes from lobster walking leg nerves. Systematic application of key chemical agents revealed separate cellular mechanisms underlying fast optical signals. Each agent exhibited mixed effects, some having a greater effect on cellular swelling and refractive index, and some altering membrane potential. Birefringence changes were tightly correlated with voltage sensitive dye signals and were perturbed by those agents that altered membrane potential. Signals from light scattered at 90 degrees corroborated the hypothesis that large angle scattering signals arise from changes in the interstitial spaces and were perturbed by those agents that altered cellular swelling and refractive index. We conclude that multiple cellular mechanisms can be exploited to measure rapid optical signals. Since birefringence produces much larger changes than scattering, the use of polarized light might lead to improvements in imaging neural activity with high temporal resolution, especially since birefringence changes corresponded closely to membrane potential.
Collapse
Affiliation(s)
- A J Foust
- Department of Veterinary and Comparative Anatomy, Pharmacology and Physiology, College of Veterinary Medicine, Washington State University, VCAPP Wegner 205, Pullman, WA 99164-6520, USA
| | | |
Collapse
|
30
|
Yao XC, George JS. Near-infrared imaging of fast intrinsic optical responses in visible light-activated amphibian retina. JOURNAL OF BIOMEDICAL OPTICS 2006; 11:064030. [PMID: 17212553 DOI: 10.1117/1.2393155] [Citation(s) in RCA: 13] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/13/2023]
Abstract
High performance functional imaging is needed for dynamic measurements of neural processing in retina. Emerging techniques for visual prosthesis also require advanced methodology for reliable validation of electromagnetic stimulation of the retina. Imaging of fast intrinsic optical responses associated with neural activation promises a variety of technical advantages over traditional single and multichannel electrophysiological techniques for these purposes, but the application of fast optical signals for neural imaging has been limited by low signal-to-noise ratio and high background light intensity. However, by using an optimized near-infrared probe light and improved optical system, we improve the optical signals substantially, allowing single pass measurements with approximately micron resolution. We image fast intrinsic optical responses with different optical modalities, i.e., bright field, dark field, and cross-polarization, from isolated retina activated by visible light stimulation. At single cell resolution, bright-field imaging discloses the maxima of optical responses approximately 5% dI/I, where dI is the dynamic optical change and I is the baseline light intensity. Dark-field imaging techniques further enhance the sensitivity of optical measurements, and show the maxima of optical responses exceeding 10% dI/I. Cross-polarized imaging provides optical sensitivity similar to dark-field imaging, but different patterns of neural activation are observed.
Collapse
Affiliation(s)
- Xin-Cheng Yao
- Los Alamos National Laboratory, MS-D454, Los Alamos, New Mexico 87545, USA.
| | | |
Collapse
|
31
|
Yao XC, George JS. Dynamic neuroimaging of retinal light responses using fast intrinsic optical signals. Neuroimage 2006; 33:898-906. [PMID: 17000120 DOI: 10.1016/j.neuroimage.2006.06.060] [Citation(s) in RCA: 25] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/28/2005] [Revised: 05/09/2006] [Accepted: 06/06/2006] [Indexed: 11/23/2022] Open
Abstract
Transient intrinsic optical responses associated with neural activation offer an attractive strategy for dynamic imaging of neural activity, and may provide a noninvasive methodology for imaging of retinal function. Here we demonstrate the feasibility of near infrared imaging of fast intrinsic optical changes in isolated frog retina activated by visible light. Using a photodiode detector in a transmitted light geometry, we routinely measured dynamic transmitted optical responses in single passes, at the level of one part in 10(4) of background light. Rapid CCD image sequences acquired with transmitted light (bright field) illumination disclosed larger fractional responses and showed evidence of multiple response components with both negative- and positive-going signals with different timecourses. Dark field imaging further enhanced the contrast and sensitivity of optical measures of neural activation. High-resolution imaging disclosed optical responses in single pixels often exceeding 5%, of background light, allowing dynamic imaging at the resolution of single cells, in single passes. Fast optical signals are closely related to identified response components of the electroretinogram. Optical responses showed complex but consistent spatial organization from frame to frame. Our experimental results and theoretical analysis suggest that the optical responses may result from dynamic volume changes corresponding to ion and water flow across the cell membrane, directly associated with the electrophysiological response.
Collapse
Affiliation(s)
- Xin-Cheng Yao
- Los Alamos National Laboratory, Biological and Quantum Physics Group (P-21), PO Box 1663, MS-D454, Los Alamos, NM 87545, USA
| | | |
Collapse
|