1
|
Twomey-Kozak J, Adu-Kwarteng K, Lunn K, Briggs DV, Hurley E, Anakwenze OA, Klifto CS. Recent Advances in the Design and Application of Shoulder Arthroplasty Implant Systems and Their Impact on Clinical Outcomes: A Comprehensive Review. Orthop Res Rev 2024; 16:205-220. [PMID: 39081796 PMCID: PMC11288362 DOI: 10.2147/orr.s312870] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Download PDF] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/31/2024] [Accepted: 07/11/2024] [Indexed: 08/02/2024] Open
Abstract
Purpose of Review This narrative review comprehensively aims to analyze recent advancements in shoulder arthroplasty, focusing on implant systems and their impact on patient outcomes. The purpose is to provide a nuanced understanding of the evolving landscape in shoulder arthroplasty, incorporating scientific, regulatory, and ethical dimensions. Recent Findings The review synthesizes recent literature on stemless implants, augmented glenoid components, inlay vs onlay configurations, convertible stems, and associated complications. Notable findings include improved patient-reported outcomes with stemless implants, variations in outcomes between inlay and onlay configurations, and the potential advantages of convertible stems. Additionally, the regulatory landscape, particularly the FDA's 510(k) pathway, is explored alongside ethical considerations, emphasizing the need for standardized international regulations. Summary Recent innovations in shoulder arthroplasty showcase promising advancements, with stemless implants demonstrating improved patient outcomes. The review underscores the necessity for ongoing research to address unresolved aspects and highlights the importance of a standardized regulatory framework to ensure patient safety globally. The synthesis of recent findings contributes to a comprehensive understanding of the current state of shoulder arthroplasty, guiding future research and clinical practices.
Collapse
Affiliation(s)
- John Twomey-Kozak
- Department of Orthopaedic Surgery, Duke University Medical Center, Durham, NC, USA
| | - Kwabena Adu-Kwarteng
- Department of Orthopaedic Surgery, Duke University Medical Center, Durham, NC, USA
| | - Kiera Lunn
- Department of Orthopaedic Surgery, Duke University Medical Center, Durham, NC, USA
| | - Damon Vernon Briggs
- Department of Orthopaedic Surgery, Duke University Medical Center, Durham, NC, USA
| | - Eoghan Hurley
- Department of Orthopaedic Surgery, Duke University Medical Center, Durham, NC, USA
| | - Oke A Anakwenze
- Department of Orthopaedic Surgery, Duke University Medical Center, Durham, NC, USA
| | - Christopher S Klifto
- Department of Orthopaedic Surgery, Duke University Medical Center, Durham, NC, USA
| |
Collapse
|
2
|
Yang J, Gong X, Li T, Xia Z, He R, Song X, Wang X, Wu J, Chen J, Wang F, Xiong R, Lin Y, Chen G, Yang L, Cai K. Tantalum Particles Promote M2 Macrophage Polarization and Regulate Local Bone Metabolism via Macrophage-Derived Exosomes Influencing the Fates of BMSCs. Adv Healthc Mater 2024; 13:e2303814. [PMID: 38497832 DOI: 10.1002/adhm.202303814] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/01/2023] [Revised: 03/07/2024] [Indexed: 03/19/2024]
Abstract
In this study, the regulatory role and mechanisms of tantalum (Ta) particles in the bone tissue microenvironment are explored. Ta particle deposition occurs in both clinical samples and animal tissues following porous Ta implantation. Unlike titanium (Ti) particles promoting M1 macrophage (Mϕ) polarization, Ta particles regulating calcium signaling pathways and promoting M2 Mϕ polarization. Ta-induced M2 Mϕ enhances bone marrow-derived mesenchymal stem cells (BMSCs) proliferation, migration, and osteogenic differentiation through exosomes (Exo) by upregulating miR-378a-3p/miR-221-5p and downregulating miR-155-5p/miR-212-5p. Ta particles suppress the pro-inflammatory and bone resorption effects of Ti particles in vivo and in vitro. In a rat femoral condyle bone defect model, artificial bone loaded with Ta particles promotes endogenous Mϕ polarization toward M2 differentiation at the defect site, accelerating bone repair. In conclusion, Ta particles modulate Mϕ polarization toward M2 and influence BMSCs osteogenic capacity through Exo secreted by M2 Mϕ, providing insights for potential bone repair applications.
Collapse
Affiliation(s)
- Junjun Yang
- Key Laboratory of Biorheological Science and Technology, Ministry of Education College of Bioengineering, Chongqing University, Chongqing, 400044, China
| | - Xiaoyuan Gong
- Center for Joint Surgery, Southwest Hospital, Army Medical University (Third Military Medical University), Chongqing, 400038, China
| | - Tao Li
- Center for Joint Surgery, Southwest Hospital, Army Medical University (Third Military Medical University), Chongqing, 400038, China
| | - Zengzilu Xia
- Key Laboratory of Biorheological Science and Technology, Ministry of Education College of Bioengineering, Chongqing University, Chongqing, 400044, China
| | - Rui He
- Center for Joint Surgery, Southwest Hospital, Army Medical University (Third Military Medical University), Chongqing, 400038, China
| | - Xiongbo Song
- Center for Joint Surgery, Southwest Hospital, Army Medical University (Third Military Medical University), Chongqing, 400038, China
| | - Xin Wang
- Center for Joint Surgery, Southwest Hospital, Army Medical University (Third Military Medical University), Chongqing, 400038, China
| | - Jiangyi Wu
- Department of Sports Medicine and Rehabilitation, Peking University Shenzhen Hospital, Shenzhen, 518036, China
| | - Jiajia Chen
- Center of Biomedical Analysis, Army Medical University (Third Military Medical University), Chongqing, 400038, China
| | - Fangzheng Wang
- Key Laboratory of Biorheological Science and Technology, Ministry of Education College of Bioengineering, Chongqing University, Chongqing, 400044, China
| | - Ran Xiong
- Center for Joint Surgery, Southwest Hospital, Army Medical University (Third Military Medical University), Chongqing, 400038, China
| | - Yangjing Lin
- Center for Joint Surgery, Southwest Hospital, Army Medical University (Third Military Medical University), Chongqing, 400038, China
| | - Guangxing Chen
- Center for Joint Surgery, Southwest Hospital, Army Medical University (Third Military Medical University), Chongqing, 400038, China
| | - Liu Yang
- Center for Joint Surgery, Southwest Hospital, Army Medical University (Third Military Medical University), Chongqing, 400038, China
| | - Kaiyong Cai
- Key Laboratory of Biorheological Science and Technology, Ministry of Education College of Bioengineering, Chongqing University, Chongqing, 400044, China
| |
Collapse
|
3
|
Cai A, Yin H, Wang C, Chen Q, Yin R, Yuan X, Kang H, Guo H. Preparation, biological activity and antibacterial properties of tantalum surface-doped Ca 2+/Zn 2+nanorods. NANOTECHNOLOGY 2024; 35:305102. [PMID: 38663375 DOI: 10.1088/1361-6528/ad4361] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 01/26/2024] [Accepted: 04/25/2024] [Indexed: 05/12/2024]
Abstract
In this research, we utilize porous tantalum, known for its outstanding elastic modulus and biological properties, as a base material in biomedical applications. The human skeletal system is rich in elements like Ca and Zn. The role of Zn is crucial for achieving a spectrum of sterilizing effects, while Ca is known to effectively enhance cell differentiation and boost cellular activity. The focus of this study is the modification of porous tantalum using a hydrothermal method to synthesize Ca2+/Zn2+-doped Ta2O5nanorods. These nanorods are subjected to extensive characterization techniques to confirm their structure and composition. Additionally, their biological performance is evaluated through a range of tests, including antibacterial assessments, MTT assays, and bacteria/cell scanning electron microscopy (SEM) analyses. The objective is to determine the most effective method of surface modification for porous tantalum, thereby laying a foundational theoretical framework for its surface enhancement.
Collapse
Affiliation(s)
- Anqi Cai
- School of Materials Science and Engineering, Shaanxi Key Laboratory of Green Preparation and Functionalization for Inorganic Materials, Shaanxi University of Science and Technology, Xi'an, 710021, People's Republic of China
| | - Hairong Yin
- School of Materials Science and Engineering, Shaanxi Key Laboratory of Green Preparation and Functionalization for Inorganic Materials, Shaanxi University of Science and Technology, Xi'an, 710021, People's Republic of China
| | - Cuicui Wang
- School of Materials Science and Engineering, Shaanxi Key Laboratory of Green Preparation and Functionalization for Inorganic Materials, Shaanxi University of Science and Technology, Xi'an, 710021, People's Republic of China
| | - Qian Chen
- School of Materials Science and Engineering, Shaanxi Key Laboratory of Green Preparation and Functionalization for Inorganic Materials, Shaanxi University of Science and Technology, Xi'an, 710021, People's Republic of China
| | - Ruixue Yin
- School of Materials Science and Engineering, Shaanxi Key Laboratory of Green Preparation and Functionalization for Inorganic Materials, Shaanxi University of Science and Technology, Xi'an, 710021, People's Republic of China
| | - Xin Yuan
- School of Materials Science and Engineering, Shaanxi Key Laboratory of Green Preparation and Functionalization for Inorganic Materials, Shaanxi University of Science and Technology, Xi'an, 710021, People's Republic of China
| | - Haoran Kang
- School of Materials Science and Engineering, Shaanxi Key Laboratory of Green Preparation and Functionalization for Inorganic Materials, Shaanxi University of Science and Technology, Xi'an, 710021, People's Republic of China
| | - Hongwei Guo
- School of Materials Science and Engineering, Shaanxi Key Laboratory of Green Preparation and Functionalization for Inorganic Materials, Shaanxi University of Science and Technology, Xi'an, 710021, People's Republic of China
| |
Collapse
|
4
|
Chin PYK, Regan W, Plausinis D, Zarzour Z, Leung F, Johnston K, Lim B, Sasyniuk T. A multicenter, randomized controlled trial comparing a second-generation uncemented trabecular metal-backed vs. cemented polyethylene glenoid component in total shoulder arthroplasty: 5-year results. J Shoulder Elbow Surg 2024; 33:1004-1016. [PMID: 38286183 DOI: 10.1016/j.jse.2023.12.004] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 08/23/2023] [Revised: 11/15/2023] [Accepted: 12/04/2023] [Indexed: 01/31/2024]
Abstract
BACKGROUND Previously, we reported early (2-year) findings from a randomized controlled trial comparing a second-generation uncemented trabecular metal-backed (TM) glenoid vs. cemented polyethylene glenoid (POLY) in patients undergoing a total shoulder arthroplasty. The purpose of the current study is to report disease-specific quality of life, clinical, patient-reported, and radiographic outcomes at midterm (5-year) from this trial. METHODS Five surgeons from 3 centers participated. Patients 18-79 years with a primary diagnosis of glenohumeral osteoarthritis were screened for eligibility. Randomization to an uncemented TM or cemented POLY glenoid was performed intra-operatively after adequate bone stock was confirmed. Study intervals were baseline, 2- and 5-year postoperative. The primary outcome was the Western Ontario Osteoarthritis Shoulder (WOOS) quality of life score. Secondary outcomes included the American Shoulder and Elbow Surgeons Standardized Shoulder Assessment Form, EuroQol-5 Dimensions, and 12-Item Short Form Health Survey scores and clinical and radiographic examinations. Radiographic images were reviewed for metal debris according to Endrizzi. Mixed effects repeated measures analysis of variance for within- and between-group comparisons were performed. RESULTS Of the 104 patients who consented, 93 were randomized (46 TM; 47 POLY). There were no differences between groups at baseline (TM: mean age 66.5 years [standard deviation (SD) 6.4], 24 male and 22 female; and POLY: mean age 68.4 years [SD 5.5], 23 male / 24 female). Mean (SD) WOOS scores at baseline and 2 and 5 years were as follows: TM, 32 (21), 92 (13), and 93 (11); POLY, 27 (15), 93 (11), and 93 (10), respectively. No statistical or clinically relevant differences were noted with patient-reported outcomes between groups. Metal debris was observed in 11 (23.9%) patients, but outcomes were not negatively impacted, and debris severity was minor (grades 1 and 2). Complication rates were similar between groups (TM: 7 of 46 [15.2%], and POLY: 8 of 47 [17.0%]; P = .813). No aseptic glenoid failures were reported, but 1 patient in the TM group required revision because of infection. CONCLUSIONS Our short-term (2-year) findings were maintained with longer follow-up. At 5 years postoperation, there were no statistically or clinically significant differences between an uncemented second-generation TM glenoid and a cemented polyethylene glenoid with respect to disease-specific quality of life or patient-reported outcomes. No glenoid implant failures were reported, and complication rates were similar between groups. Only one complication was glenoid related (1 infection in the TM group). Metal debris was observed in 23.9% of patients with a TM glenoid but did not negatively influence implant survival, patient-reported outcomes, or shoulder function.
Collapse
Affiliation(s)
- Patrick Y K Chin
- Department of Orthopaedics, University of British Columbia, Vancouver, BC, Canada
| | - William Regan
- Department of Orthopaedics, University of British Columbia, Vancouver, BC, Canada
| | - Derek Plausinis
- Department of Orthopaedics, University of British Columbia, Vancouver, BC, Canada
| | - Zane Zarzour
- Department of Orthopaedics, University of British Columbia, Vancouver, BC, Canada; Department of Family Medicine, University of Victoria, Victoria, BC, Canada
| | - Fay Leung
- Department of Orthopaedics, University of British Columbia, Vancouver, BC, Canada
| | - Kayla Johnston
- Department of Orthopaedics, University of British Columbia, Vancouver, BC, Canada
| | - Brendan Lim
- Department of Orthopaedics, University of British Columbia, Vancouver, BC, Canada
| | - Treny Sasyniuk
- Department of Orthopaedics, University of British Columbia, Vancouver, BC, Canada.
| |
Collapse
|
5
|
Cai A, Yin H, Wang C, Chen Q, Song Y, Yin R, Yuan X, Kang H, Guo H. Bioactivity and antibacterial properties of zinc-doped Ta 2O 5nanorods on porous tantalum surface. Biomed Mater 2023; 18:065011. [PMID: 37729922 DOI: 10.1088/1748-605x/acfbd0] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/09/2023] [Accepted: 09/20/2023] [Indexed: 09/22/2023]
Abstract
This paper focuses on the preparation of Zn2+-doped Ta2O5nanorods on porous tantalum using the hydrothermal method. Porous tantalum is widely used in biomedical materials due to its excellent elastic modulus and biological activity. Porous tantalum has an elastic modulus close to that of human bone, and its large specific surface area is conducive to promoting cell adhesion. Zinc is an important component of human bone, which not only has spectral bactericidal properties, but also has no cytotoxicity. The purpose of this study is to provide a theoretical basis for the surface modification of porous tantalum and to determine the best surface modification method. The surface structure of the sample was characterized by x-ray diffractometer, x-ray photoelectron spectroscopy, scanning electron microscope, transmission electron microscope, and the Zn-doped Ta2O5nanorods are characterized by antibacterial test, MTT test, ICP and other methods. The sample has good antibacterial properties and no cytotoxicity. The results of this study have potential implications for the development of new and improved biomedical materials.
Collapse
Affiliation(s)
- Anqi Cai
- School of Materials Science and Engineering, Shaanxi Key Laboratory of Green Preparation and Functionalization for Inorganic Materials, Shaanxi University of Science and Technology, Xi'an 710021, People's Republic of China
| | - Hairong Yin
- School of Materials Science and Engineering, Shaanxi Key Laboratory of Green Preparation and Functionalization for Inorganic Materials, Shaanxi University of Science and Technology, Xi'an 710021, People's Republic of China
| | - Cuicui Wang
- School of Materials Science and Engineering, Shaanxi Key Laboratory of Green Preparation and Functionalization for Inorganic Materials, Shaanxi University of Science and Technology, Xi'an 710021, People's Republic of China
| | - Qian Chen
- School of Materials Science and Engineering, Shaanxi Key Laboratory of Green Preparation and Functionalization for Inorganic Materials, Shaanxi University of Science and Technology, Xi'an 710021, People's Republic of China
| | - Yingxuan Song
- School of Materials Science and Engineering, Shaanxi Key Laboratory of Green Preparation and Functionalization for Inorganic Materials, Shaanxi University of Science and Technology, Xi'an 710021, People's Republic of China
| | - Ruixue Yin
- School of Materials Science and Engineering, Shaanxi Key Laboratory of Green Preparation and Functionalization for Inorganic Materials, Shaanxi University of Science and Technology, Xi'an 710021, People's Republic of China
| | - Xin Yuan
- School of Materials Science and Engineering, Shaanxi Key Laboratory of Green Preparation and Functionalization for Inorganic Materials, Shaanxi University of Science and Technology, Xi'an 710021, People's Republic of China
| | - Haoran Kang
- School of Materials Science and Engineering, Shaanxi Key Laboratory of Green Preparation and Functionalization for Inorganic Materials, Shaanxi University of Science and Technology, Xi'an 710021, People's Republic of China
| | - Hongwei Guo
- School of Materials Science and Engineering, Shaanxi Key Laboratory of Green Preparation and Functionalization for Inorganic Materials, Shaanxi University of Science and Technology, Xi'an 710021, People's Republic of China
| |
Collapse
|
6
|
Friedman RJ, Boettcher ML, Grey S, Flurin PH, Wright TW, Zuckerman JD, Eichinger JK, Roche C. Comparison of long-term clinical and radiological outcomes for cemented keel, cemented peg, and hybrid cage glenoids with anatomical total shoulder arthroplasty using the same humeral component. Bone Joint J 2023; 105-B:668-678. [PMID: 37259565 DOI: 10.1302/0301-620x.105b6.bjj-2022-1033.r2] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 06/02/2023]
Abstract
Aims The aim of this study was to longitudinally compare the clinical and radiological outcomes of anatomical total shoulder arthroplasty (aTSA) up to long-term follow-up, when using cemented keel, cemented peg, and hybrid cage peg glenoid components and the same humeral system. Methods We retrospectively analyzed a multicentre, international clinical database of a single platform shoulder system to compare the short-, mid-, and long-term clinical outcomes associated with three designs of aTSA glenoid components: 294 cemented keel, 527 cemented peg, and 981 hybrid cage glenoids. Outcomes were evaluated at 4,746 postoperative timepoints for 1,802 primary aTSA, with a mean follow-up of 65 months (24 to 217). Results Relative to their preoperative condition, each glenoid cohort had significant improvements in clinical outcomes from two years to ten years after surgery. Patients with cage glenoids had significantly better clinical outcomes, with higher patient-reported outcome scores and significantly increased active range of motion, compared with those with keel and peg glenoids. Those with cage glenoids also had significantly fewer complications (keel: 13.3%, peg: 13.1%, cage: 7.4%), revisions (keel: 7.1%, peg 9.7%, cage 3.5%), and aseptic glenoid loosening and failure (keel: 4.7%, peg: 5.8%, cage: 2.5%). Regarding radiological outcomes, 70 patients (11.2%) with cage glenoids had glenoid radiolucent lines (RLLs). The cage glenoid RLL rate was 3.3-times (p < 0.001) less than those with keel glenoids (37.3%) and 4.6-times (p < 0.001) less than those with peg glenoids (51.2%). Conclusion These findings show that good long-term clinical and radiological outcomes can be achieved with each of the three aTSA designs of glenoid component analyzed in this study. However, there were some differences in clinical and radiological outcomes: generally, cage glenoids performed best, followed by cemented keel glenoids, and finally cemented peg glenoids.
Collapse
Affiliation(s)
- Richard J Friedman
- Orthopaedics Department, Medical University of South Carolina, Charleston, South Carolina, USA
| | - Marissa L Boettcher
- Department of Radiology and Medical Imaging, University of Virginia, Charlottesville, Virginia, USA
| | - Sean Grey
- Ortho Center of the Rockies, Fort Collins, Colorado, USA
| | | | - Thomas W Wright
- Orthopaedics and Sports Medicine Institute, University of Florida, Gainesville, Florida, USA
| | - Joseph D Zuckerman
- Department of Orthopaedic Surgery, Division of Shoulder & Elbow, NYU Langone Orthopedic Hospital, New York, New York, USA
| | - Josef K Eichinger
- Orthopaedics Department, Medical University of South Carolina, Charleston, South Carolina, USA
| | | |
Collapse
|
7
|
Clinical and radiographic outcomes following anatomic total shoulder arthroplasty utilizing an inset glenoid component at 2-year minimum follow-up: a dual center study. J Shoulder Elbow Surg 2022; 32:1222-1230. [PMID: 36584872 DOI: 10.1016/j.jse.2022.11.021] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 07/06/2022] [Revised: 11/18/2022] [Accepted: 11/20/2022] [Indexed: 12/29/2022]
Abstract
BACKGROUND Anatomic total shoulder arthroplasty (aTSA) is a successful and reproducible treatment for patients with painful glenohumeral arthritis. However, long-term outcomes using traditional onlay glenoid components have been tempered by glenoid loosening. Inset components have been proposed to minimize glenoid loosening by reducing edge-loading and opposite-edge lift-off forces with humeral translation. Successful short- and long-term outcomes have been reported while using inset glenoid implants. The current study is the largest study presenting a minimum of 2-year follow-up data following aTSA with an all-polyethylene inset glenoid component (Shoulder Innovations, Holland, MI, USA). METHODS A dual center, retrospective review of patients undergoing aTSA using an Inset glenoid component by 2 fellowship-trained shoulder surgeons at 2 separate institutions from August, 2016, to August, 2019, was performed. Minimum follow-up was 2 years. Range of motion (ROM), visual analog scale (VAS) pain scores, Single Assessment Numeric Evaluation (SANE), and American Shoulder and Elbow Surgeons (ASES) scores were obtained. Radiographic outcomes, including central peg lucency and glenoid loosening, were assessed by 3 independent reviewers on the postoperative Grashey and axillary radiographs obtained at the final follow-up. RESULTS Seventy-five shoulders were included for the final analysis. The mean age of the entire cohort was 64 (±11.4) years. Twenty-one (28%) glenoids were type A1, 10 (13.3%) were type A2, 13 (17.3%) were type B1, 22 (29.3%) were type B2, 6 (8%) were type B3, and 3 (4%) were type D. At a minimum follow-up of 24 months (mean: 28.7 months), a significant improvement in ROM in all planes was observed. Significant improvements in VAS (5.1-0.9, P < .001), SANE (39.5-91.2, P < .001), and ASES (43.7-86.6, P < .001) scores were observed. There were 4 (5.3%) cases of central peg lucency about the inset glenoid component and one (1.3%) case of glenoid loosening. No revisions were performed for glenoid loosening. CONCLUSION At a minimum of 2 years postoperatively, there were significant improvements in ROM, VAS, SANE, and ASES scores with very low rates of central peg lucency and glenoid loosening in patients undergoing aTSA with an inset glenoid component. Further work is needed to determine the long-term benefit of this novel implant.
Collapse
|
8
|
Murphy J, Todd E, Wright MA, Murthi AM. Evaluation of clinical and radiographic outcomes after total shoulder arthroplasty with inset Trabecular Metal-backed glenoid. J Shoulder Elbow Surg 2022; 31:971-977. [PMID: 34774775 DOI: 10.1016/j.jse.2021.10.014] [Citation(s) in RCA: 6] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 06/14/2021] [Revised: 10/01/2021] [Accepted: 10/11/2021] [Indexed: 02/01/2023]
Abstract
BACKGROUND Trabecular Metal (TM)-backed glenoid implants were introduced for their theoretical ability to increase osseointegration while minimizing wear and the risk of loosening in total shoulder arthroplasty (TSA). Initial follow-up studies of TM-backed glenoids demonstrated high rates of metallic debris formation around the implant site, raising concerns about longevity. More recent data suggest that metallic debris formation may be less prevalent than previously reported and that the implants may have positive long-term outcomes regardless of debris. The goal of our study was to assess the clinical and radiographic outcomes at mid-term follow-up of TSA using a TM-backed glenoid implant placed with full backside support using an inset technique. We hypothesized that our clinical and radiographic outcomes would be good using this technique. METHODS We retrospectively reviewed the charts of 39 patients who underwent 41 TSA procedures with a Zimmer Biomet TM-backed glenoid component performed by a single surgeon between January 2010 and March 2016. After exclusions for death unrelated to surgery and loss to follow-up, 35 patients (37 shoulders) with minimum 2-year clinical follow-up were included in the study. The glenoids were all placed in an inset fashion with full backside support. Clinical, patient-reported, and radiographic outcomes were analyzed. RESULTS The average follow-up period was 7.2 years (range, 2-11 years). At final follow-up, average shoulder elevation was 153° ± 22° and average external rotation was 53° ± 12°. The average American Shoulder and Elbow Surgeons score was 86.8 ± 19.0, and the average visual analog scale score was 1.3 ± 2.4. Metallic debris was found in 9 shoulders (27%), and radiolucency was observed around the glenoid components in 13 shoulders (39%) on the final postoperative radiographs. Metallic debris and radiolucency findings were low in severity, with average grades of 0.32 (standard deviation, 0.54) and 0.39 (standard deviation, 0.50), respectively. There were no reoperations. CONCLUSION This study of 37 shoulders undergoing TSA with a TM-backed glenoid demonstrated 100% implant survivorship at an average follow-up of 7 years. Clinical outcomes were excellent despite the occurrence of some metallic debris formation. The findings suggest that a TM-backed glenoid component implanted in an inset fashion to achieve full backside support can provide good clinical and patient-reported outcomes in TSA patients at mid-term follow-up and suggest that continued consideration of the role of TM-backed glenoids and the optimal technique for implantation may be warranted.
Collapse
Affiliation(s)
- Jordan Murphy
- Department of Orthopaedic Surgery, MedStar Union Memorial Hospital, Baltimore, MD, USA
| | - Evan Todd
- Georgetown University School of Medicine, Washington, DC, USA
| | - Melissa A Wright
- Department of Orthopaedic Surgery, MedStar Union Memorial Hospital, Baltimore, MD, USA
| | - Anand M Murthi
- Department of Orthopaedic Surgery, MedStar Union Memorial Hospital, Baltimore, MD, USA.
| |
Collapse
|
9
|
Fokter SK, Gubeljak N, Punzón-Quijorna E, Pelicon P, Kelemen M, Vavpetič P, Predan J, Ferlič L, Novak I. Total Knee Replacement with an Uncemented Porous Tantalum Tibia Component: A Failure Analysis. MATERIALS 2022; 15:ma15072575. [PMID: 35407908 PMCID: PMC8999729 DOI: 10.3390/ma15072575] [Citation(s) in RCA: 11] [Impact Index Per Article: 3.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 02/20/2022] [Revised: 03/22/2022] [Accepted: 03/30/2022] [Indexed: 11/16/2022]
Abstract
Porous tantalum has been extensively used in orthopaedic surgery, including uncemented total knee arthroplasty (TKA). Favourable results were reported with earlier monobloc tibial components and the design evolved to modular implants. We aimed to analyse possible causes for extensive medial tibia bone loss, resulting in modular porous tantalum tibia baseplate fracture after primary TKA. Retrieved tissue samples were scanned with 3 MeV focused proton beam for Proton-Induced X-ray Emission (micro-PIXE) elemental analysis. Fractographic and microstructural analysis were performed by stereomicroscopy. A full 3D finite-element model was made for numerical analysis of stress-strain conditions of the tibial baseplate. Histological examination of tissue underneath the broken part of the tibial baseplate revealed dark-stained metal debris, which was confirmed by micro-PIXE to consist of tantalum and titanium. Fractographic analysis and tensile testing showed that the failure of the tibial baseplate fulfilled the criteria of a typical fatigue fracture. Microstructural analysis of the contact surface revealed signs of bone ingrowth in 22.5% of the surface only and was even less pronounced in the medial half of the tibial baseplate. Further studies are needed to confirm the responsibility of metal debris for an increased bone absorption leading to catastrophic tibial tray failure.
Collapse
Affiliation(s)
- Samo K. Fokter
- Department of Orthopaedics, University Medical Centre Maribor, Ljubljanska 5, 2000 Maribor, Slovenia;
- Correspondence: ; Tel.: +386-41-772102
| | - Nenad Gubeljak
- Faculty of Mechanical Engineering, University of Maribor, Smetanova 17, 2000 Maribor, Slovenia; (N.G.); (J.P.); (L.F.)
| | - Esther Punzón-Quijorna
- Department of Low and Medium Energy Physics F2, Jožef Stefan Institute, Jamova 39, 1000 Ljubljana, Slovenia; (E.P.-Q.); (P.P.); (M.K.); (P.V.)
| | - Primož Pelicon
- Department of Low and Medium Energy Physics F2, Jožef Stefan Institute, Jamova 39, 1000 Ljubljana, Slovenia; (E.P.-Q.); (P.P.); (M.K.); (P.V.)
| | - Mitja Kelemen
- Department of Low and Medium Energy Physics F2, Jožef Stefan Institute, Jamova 39, 1000 Ljubljana, Slovenia; (E.P.-Q.); (P.P.); (M.K.); (P.V.)
| | - Primož Vavpetič
- Department of Low and Medium Energy Physics F2, Jožef Stefan Institute, Jamova 39, 1000 Ljubljana, Slovenia; (E.P.-Q.); (P.P.); (M.K.); (P.V.)
| | - Jožef Predan
- Faculty of Mechanical Engineering, University of Maribor, Smetanova 17, 2000 Maribor, Slovenia; (N.G.); (J.P.); (L.F.)
| | - Luka Ferlič
- Faculty of Mechanical Engineering, University of Maribor, Smetanova 17, 2000 Maribor, Slovenia; (N.G.); (J.P.); (L.F.)
| | - Igor Novak
- Department of Orthopaedics, University Medical Centre Maribor, Ljubljanska 5, 2000 Maribor, Slovenia;
| |
Collapse
|
10
|
Chin PYK, Regan WD, Plausinis D, Zarzour ZD, Leung F, Sasyniuk TM, Lim B, Sayre EC. Two-year results of a multi-centre, randomized controlled trial comparing a second-generation uncemented trabecular metal-backed versus cemented polyethylene glenoid component in total shoulder arthroplasty. Bone Jt Open 2021; 2:728-736. [PMID: 34488426 PMCID: PMC8479846 DOI: 10.1302/2633-1462.29.bjo-2021-0073.r1] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/08/2022] Open
Abstract
Aims To report early (two-year) postoperative findings from a randomized controlled trial (RCT) investigating disease-specific quality of life (QOL), clinical, patient-reported, and radiological outcomes in patients undergoing a total shoulder arthroplasty (TSA) with a second-generation uncemented trabecular metal (TM) glenoid versus a cemented polyethylene glenoid (POLY) component. Methods Five fellowship-trained surgeons from three centres participated. Patients aged between 18 and 79 years with a primary diagnosis of glenohumeral osteoarthritis were screened for eligibility. Patients were randomized intraoperatively to either a TM or POLY glenoid component. Study intervals were: baseline, six weeks, six-, 12-, and 24 months postoperatively. The primary outcome was the Western Ontario Osteoarthritis Shoulder QOL score. Radiological images were reviewed for metal debris. Mixed effects repeated measures analysis of variance for within and between group comparisons were performed. Results A total of 93 patients were randomized (46 TM; 47 POLY). No significant or clinically important differences were found with patient-reported outcomes at 24-month follow-up. Regarding the glenoid components, there were no complications or revision surgeries in either group. Grade 1 metal debris was observed in three (6.5%) patients with TM glenoids at 24 months but outcomes were not negatively impacted. Conclusion Early results from this RCT showed no differences in disease-specific QOL, radiographs, complication rates, or shoulder function between uncemented second-generation TM and cemented POLY glenoids at 24 months postoperatively. Revision surgeries and reoperations were reported in both groups, but none attributed to glenoid implant failure. At 24 months postoperatively, Grade 1 metal debris was found in 6.5% of patients with a TM glenoid but did not negatively influence patient-reported outcomes. Longer-term follow-up is needed and is underway. Cite this article: Bone Jt Open 2021;2(9):728–736.
Collapse
Affiliation(s)
| | | | | | - Zane D Zarzour
- The University of British Columbia, Vancouver, Canada.,The University of Victoria, Victoria, Canada
| | - Fay Leung
- The University of British Columbia, Vancouver, Canada
| | | | - Brendan Lim
- The University of British Columbia, Vancouver, Canada
| | | |
Collapse
|
11
|
Chen RE, Brown AM, Greenstein AS, Mannava S, Voloshin I. Radiographic and clinical outcomes of second generation Trabecular Metal™ glenoid components in total shoulder arthroplasty. Shoulder Elbow 2021; 13:416-425. [PMID: 34394739 PMCID: PMC8355655 DOI: 10.1177/1758573220909981] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 09/15/2019] [Revised: 01/28/2020] [Accepted: 02/10/2020] [Indexed: 01/21/2023]
Abstract
BACKGROUND Total shoulder arthroplasty with second generation porous tantalum glenoid implants (Trabecular Metal™) has shown good short-term outcomes, but mid-term outcomes are unknown. This study describes the clinical, radiographic, and patient-rated mid-term outcomes of total shoulder arthroplasty utilizing cemented Trabecular Metal™ glenoid components. METHODS Patients who underwent anatomic total shoulder arthroplasty with cemented Trabecular Metal™ glenoid components for primary osteoarthritis were identified for minimum five-year follow-up. The primary outcome measure was implant survival; secondary outcome measures included patient-rated outcome scores, shoulder range of motion findings, and radiographic analysis. RESULTS Twenty-seven patients were enrolled in the study. Twenty-one patients had full radiographic follow-up. Mean follow-up was 6.6 years. There was 100% implant survival. Shoulder range of motion significantly improved and the mean American Shoulder and Elbow Society score was 89.8. There was presence of metal debris radiographically in 24% of patients. Twenty-nine percent of patients had evidence of radiolucency. Fourteen percent of patients had moderate superior subluxation. CONCLUSION Total shoulder arthroplasty with second generation cemented Trabecular Metal™ glenoid components yielded good outcomes at mean 6.6-year follow-up. Metal debris incidence and clinical outcomes were similar to short-term findings. The presence of metal debris did not significantly affect clinical outcomes. Continued observation of these patients will elucidate longer-term implant survival.
Collapse
Affiliation(s)
| | | | | | | | - Ilya Voloshin
- Ilya Voloshin, Department of Orthopaedic
Surgery and Rehabilitation, University of Rochester Medical Center, 601 Elmwood
Ave, Rochester, NY 14642, USA.
| |
Collapse
|
12
|
Huang G, Pan ST, Qiu JX. The Clinical Application of Porous Tantalum and Its New Development for Bone Tissue Engineering. MATERIALS (BASEL, SWITZERLAND) 2021; 14:2647. [PMID: 34070153 PMCID: PMC8158527 DOI: 10.3390/ma14102647] [Citation(s) in RCA: 24] [Impact Index Per Article: 6.0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 04/09/2021] [Revised: 05/06/2021] [Accepted: 05/13/2021] [Indexed: 12/13/2022]
Abstract
Porous tantalum (Ta) is a promising biomaterial and has been applied in orthopedics and dentistry for nearly two decades. The high porosity and interconnected pore structure of porous Ta promise fine bone ingrowth and new bone formation within the inner space, which further guarantee rapid osteointegration and bone-implant stability in the long term. Porous Ta has high wettability and surface energy that can facilitate adherence, proliferation and mineralization of osteoblasts. Meanwhile, the low elastic modulus and high friction coefficient of porous Ta allow it to effectively avoid the stress shield effect, minimize marginal bone loss and ensure primary stability. Accordingly, the satisfactory clinical application of porous Ta-based implants or prostheses is mainly derived from its excellent biological and mechanical properties. With the advent of additive manufacturing, personalized porous Ta-based implants or prostheses have shown their clinical value in the treatment of individual patients who need specially designed implants or prosthesis. In addition, many modification methods have been introduced to enhance the bioactivity and antibacterial property of porous Ta with promising in vitro and in vivo research results. In any case, choosing suitable patients is of great importance to guarantee surgical success after porous Ta insertion.
Collapse
Affiliation(s)
| | | | - Jia-Xuan Qiu
- Department of Oral and Maxillofacial Surgery, The First Affiliated Hospital of Nanchang University, Nanchang 330006, China; (G.H.); (S.-T.P.)
| |
Collapse
|
13
|
Chen RE, Brown AM, Greenstein AS, Miller RJ, Mannava S, Voloshin I. Cemented versus uncemented fixation of second-generation Trabecular Metal glenoid components: minimum 5-year outcomes. J Shoulder Elbow Surg 2021; 30:e147-e156. [PMID: 32750528 DOI: 10.1016/j.jse.2020.07.025] [Citation(s) in RCA: 9] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 03/28/2020] [Revised: 07/09/2020] [Accepted: 07/19/2020] [Indexed: 02/01/2023]
Abstract
BACKGROUND Total shoulder arthroplasty (TSA) with second-generation Trabecular Metal™ implants (Zimmer, Warsaw, IN, USA) has shown good short-term outcomes. Differences in outcomes between cemented and uncemented fixation are unknown. This study compared the clinical, radiographic, and patient-rated outcomes of TSA with cemented vs. uncemented TM glenoids at minimum 5-year follow-up. METHODS Patients who underwent anatomic TSA with second-generation TM glenoid components for primary osteoarthritis were identified for minimum 5-year follow-up. The patients were divided into 2 groups: cemented and uncemented glenoid fixation. Outcome measures included implant survival, patient-rated outcome scores (Patient-Reported Outcomes Measurement Information System [PROMIS] and American Shoulder and Elbow Surgeons scores), shoulder range of motion, and radiographic analysis. Findings were compared between groups. RESULTS The study included 55 shoulders: 27 in the cemented group (21 with full radiographic follow-up) and 28 in the uncemented group (22 with full radiographic follow-up). Both groups had similar follow-up times (6.6 years in cemented group vs. 6.7 years in uncemented group, P = .60). Moreover, the groups did not differ significantly in sex composition, age at the time of surgery, or preoperative Walch glenoid grade distribution. No patients required revision surgery. The 2 groups had similar preoperative range of motion, but patients in the uncemented group had greater follow-up forward flexion (P = .03), external rotation (P < .01), and lateral elevation (P = .03) than did patients in the cemented group. PROMIS scores were not significantly different between groups. American Shoulder and Elbow Surgeons scores were similar (89.8 in cemented group vs. 94.1 in uncemented group, P = .21). Mid-term radiographs showed a metal debris rate of 24% in the cemented group and 27% in the uncemented group. Although these values were not significantly different (P = .90), the frequency of mild metal debris (grade 1-2), when present, was greater in the uncemented group (grade 2 in 6 shoulders) than in the cemented group (grade 1 in 4 and grade 2 in 1, P = .02). There was a greater presence of mild (grade 1) radiolucent lines in the uncemented group (64%) than in the cemented group (29%, P < .01). No glenoid had evidence of loosening (defined by a change in position or radiolucent lines > 2 mm). The presence of metal debris and radiolucent lines did not have a significant effect on clinical outcomes. CONCLUSION At minimum 5-year follow-up, TSA patients with TM glenoids demonstrated excellent clinical and patient-reported outcomes with a 100% implant survival rate, regardless of cemented vs. uncemented fixation. However, the uncemented group showed a significantly higher rate of radiolucent lines and a higher frequency of mild metal debris. These radiographic findings did not affect the clinical outcomes, and their implications for long-term outcomes and prosthesis survival is unknown.
Collapse
Affiliation(s)
- Raymond E Chen
- Department of Orthopedics and Rehabilitation, University of Rochester Medical Center, Rochester, NY, USA
| | - Alexander M Brown
- Department of Orthopedics and Rehabilitation, University of Rochester Medical Center, Rochester, NY, USA
| | - Alexander S Greenstein
- Department of Orthopedics and Rehabilitation, University of Rochester Medical Center, Rochester, NY, USA
| | - Richard J Miller
- Department of Orthopedics and Rehabilitation, University of Rochester Medical Center, Rochester, NY, USA
| | - Sandeep Mannava
- Department of Orthopedics and Rehabilitation, University of Rochester Medical Center, Rochester, NY, USA
| | - Ilya Voloshin
- Department of Orthopedics and Rehabilitation, University of Rochester Medical Center, Rochester, NY, USA.
| |
Collapse
|
14
|
Computed tomographic evaluation of glenoid joint line restoration with glenoid bone grafting and reverse shoulder arthroplasty in patients with significant glenoid bone loss. J Shoulder Elbow Surg 2021; 30:599-608. [PMID: 33152500 DOI: 10.1016/j.jse.2020.09.031] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 03/11/2020] [Revised: 09/13/2020] [Accepted: 09/29/2020] [Indexed: 02/01/2023]
Abstract
BACKGROUND Restoration of native glenohumeral joint line is important for a successful outcome after reverse shoulder arthroplasty (RSA). The aims of this study were to quantify the restoration of glenoid joint line after structural bone grafting and RSA, and to evaluate graft incorporation, correction of glenoid version, and rate of notching. METHODS This is a retrospective review of 21 patients who underwent RSA (20 primary, 1 revision) with glenoid bone grafting (15 autografts, 6 allografts). Grammont design implants and baseplate with long peg were used in all patients. Preoperative and postoperative 3D models were created using MIMICS 21.0. Preoperative defects were classified, and postoperative joint line restoration was assessed based on the lateral aspect of the base of the coracoid. Postoperative computed tomographic (CT) scans were evaluated for graft incorporation, version correction, and presence of notching. RESULTS Preoperative glenoid defects were classified as massive (5%), large (29%), moderate (52%), and small (14%). The average preoperative version was 8° of retroversion. The average postoperative version was 5° of retroversion. The average preoperative medialization was noted to be 8.4 mm medial to native joint line or 0.6 mm (range -16.8 to 13.2) lateral to the coracoid base. The postoperative CT scans demonstrated a mean joint line at 12.1 mm (range 1.3-22.4) lateral to the coracoid base. At the 3-month follow-up, all patients demonstrated graft incorporation on CT scans. Graft osteolysis was observed on CT scan in 4.8% of patients at a mean follow-up of 19.5 months. DISCUSSION Structural bone grafting of glenoid defect effectively re-creates the glenoid anatomy, restores glenoid bone stock, re-creates the true glenohumeral joint line, and corrects glenoid deformity. The use of bone grafting also allows lateralization of the baseplate and glenosphere, reducing the risk of severe scapular notching. CONCLUSION Restoration of the glenoid joint line was achieved in all patients. Glenoid bone grafting is a viable option for restoring glenoid joint line in cases of significant glenoid defects encountered during RSA.
Collapse
|
15
|
Malahias MA, Chytas D, Kostretzis L, Trellopoulos A, Brilakis E, Antonogiannakis E. Modern trabecular metal-backed glenoid components in total shoulder arthroplasty: What is the evidence? A systematic review. Shoulder Elbow 2021; 13:29-37. [PMID: 33717216 PMCID: PMC7905522 DOI: 10.1177/1758573220914277] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 08/08/2019] [Revised: 02/28/2020] [Accepted: 02/29/2020] [Indexed: 11/17/2022]
Abstract
BACKGROUND A number of papers have been published reporting on the clinical performance of modern trabecular metal-backed glenoid components in total shoulder arthroplasty. However, no systematic review of the literature has been published to date. METHODS The US National Library of Medicine (PubMed/MEDLINE), and the Cochrane Database of Systematic Reviews and EMBASE were queried for publications from January 1980 to October 2019 utilizing keywords pertinent to total shoulder arthroplasty, trabecular metal, and clinical outcomes. RESULTS Overall, seven articles were included for analysis (322 operated shoulders, mean follow-up range: 2-4 years). The survival rate of modern trabecular metal-backed glenoid components was 96% (309 out of 322 cases) at 43 months mean follow-up, while the rate of aseptic loosening was 0.3% (1 out of 322 cases). There were 35 cases (10.9%) with glenoid component radiolucency (one of them required revision), and 37 cases (11.5%) of metal debris formation, with four of them undergoing revision. CONCLUSIONS There was low quality evidence to show that the use of modern trabecular metal-backed glenoid components in total shoulder arthroplasty may be safe and effective at short-term follow-up. However, this analysis showed alarmingly high rates of both radiolucency of the glenoid component and metal debris formation which raise concern for potential failure of this glenoid component in the long term. Therefore, we feel that modern trabecular metal-backed glenoid components should be still used with caution as part of a structured surveillance or research program until we know if there is a detriment to the prosthesis in the medium to long term.Level: Systematic review, IV.
Collapse
Affiliation(s)
- Michael-Alexander Malahias
- 3rd Orthopaedic Department, Hygeia Hospital, Athens, Greece,Michael-Alexander Malahias, 3rd Orthopaedic Department, Hygeia Hospital, Erythrou Stavrou 4, Marousi, Athens 15123, Greece.
| | - Dimitrios Chytas
- 2nd Orthopaedic Department, School of Medicine, National and Kapodistrian University of Athens, Athens, Greece
| | | | | | | | | |
Collapse
|
16
|
Kim DM, Alabdullatif F, Aldeghaither M, Shin MJ, Kim H, Park D, Kholinne E, Jeon IH, Koh KH. Do Modern Designs of Metal-Backed Glenoid Components Show Improved Clinical Results in Total Shoulder Arthroplasty? A Systematic Review of the Literature. Orthop J Sports Med 2020; 8:2325967120950307. [PMID: 33062762 PMCID: PMC7536381 DOI: 10.1177/2325967120950307] [Citation(s) in RCA: 13] [Impact Index Per Article: 2.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 03/07/2020] [Accepted: 04/10/2020] [Indexed: 11/16/2022] Open
Abstract
Background: Despite the increased popularity of reverse total shoulder arthroplasty,
total shoulder arthroplasty is the standard treatment for advanced shoulder
arthritis in young adult patients. Conventional metal-backed glenoid (MBG)
designs result in more loosening and revision surgery compared with cemented
polyethylene glenoid components. However, modern MBG designs have been
recently devised to overcome such drawbacks. Purpose: To compare the radiolucency, loosening, and failure rates of modern MBG
designs with those of conventional designs. Study Design: Systematic review; Level of evidence, 4. Methods: A search for relevant articles was carried out using the PubMed, Cochrane
Library, and Embase databases using MeSH (Medical Subject Headings) terms
and natural keywords. A total of 362 articles were screened. We
descriptively analyzed numerical data between the groups and statistically
analyzed categorical data, such as the presence of loosening, failure, and
revision surgery. The main outcome was the rate of revision surgery or
failure. Subgroup analysis according to follow-up duration was performed to
reduce heterogeneity. Results: A total of 25 articles (2036 shoulders) were included; 15 articles (1579
shoulders) involved a conventional MBG design, and 10 (457 shoulders)
involved a modern design. The mean age of the patients was 64.2 and 66.5
years in the conventional and modern design groups, respectively, with a
mean follow-up duration of 102.0 and 56.1 months, a mean gain of forward
elevation of 35.1° and 61.7°, and a mean gain of external rotation of 24.2°
and 39.2°. The rate of radiolucency was 48.0% and 16.7%, the rate of
loosening was 11.2% and 4.9%, and the rate of revision was 15.9% and 2.4%,
for the conventional and modern design groups, respectively. Subgroup
analysis according to follow-up duration showed that the rates of loosening
and revision were significantly lower in the modern design group
(P < .001). Conclusion: Our findings suggest that modern MBG designs showed significantly lower
loosening and failure rates than conventional designs. The overall results
of the comparison, including loosening, failure, change in range of motion,
and clinical scores, indicate that modern MBG designs are promising. More
long-term follow-up studies on modern MBGs should be conducted.
Collapse
Affiliation(s)
- Dong Min Kim
- Department of Orthopedic Surgery, Asan Medical Center, University of Ulsan College of Medicine, Seoul, Republic of Korea.,Department of Orthopedic Surgery, Kangnam Korea Hospital, Seoul, Republic of Korea
| | | | | | - Myung Jin Shin
- Department of Orthopedic Surgery, Asan Medical Center, University of Ulsan College of Medicine, Seoul, Republic of Korea
| | - Hyojune Kim
- Department of Orthopedic Surgery, Asan Medical Center, University of Ulsan College of Medicine, Seoul, Republic of Korea
| | - Dongjun Park
- Department of Orthopedic Surgery, Asan Medical Center, University of Ulsan College of Medicine, Seoul, Republic of Korea
| | - Erica Kholinne
- Department of Orthopedic Surgery, Asan Medical Center, University of Ulsan College of Medicine, Seoul, Republic of Korea.,Department of Orthopedic Surgery, St Carolus Hospital, Jakarta, Indonesia
| | - In-Ho Jeon
- Department of Orthopedic Surgery, Asan Medical Center, University of Ulsan College of Medicine, Seoul, Republic of Korea
| | - Kyoung Hwan Koh
- Department of Orthopedic Surgery, Asan Medical Center, University of Ulsan College of Medicine, Seoul, Republic of Korea
| |
Collapse
|
17
|
Dillon MT, Chan PH, Prentice HA, Burfeind WE, Yian EH, Singh A, Paxton EW, Navarro RA. The association between glenoid component design and revision risk in anatomic total shoulder arthroplasty. J Shoulder Elbow Surg 2020; 29:2089-2096. [PMID: 32507730 DOI: 10.1016/j.jse.2020.02.024] [Citation(s) in RCA: 23] [Impact Index Per Article: 4.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 12/12/2019] [Revised: 02/10/2020] [Accepted: 02/20/2020] [Indexed: 02/01/2023]
Abstract
INTRODUCTION Anatomic total shoulder arthroplasty (TSA) is a proven treatment for glenohumeral joint osteoarthritis, with superior results compared with hemiarthroplasty. However, glenoid component loosening remains a problem and is one of the most common causes of failure in TSA. Multiple component designs have been developed in an attempt to reduce loosening rates. The purpose of this study was to evaluate risk of revision after anatomic TSA according to the glenoid component design. METHODS We conducted a cohort study including patients aged ≥18 years who underwent primary elective TSA for the diagnosis of osteoarthritis between 2010 and 2017. Patients with missing implant information, who received stemless humeral implants, or who received augmented glenoid implants, were excluded. Glenoid component designs used were categorized into 4 mutually exclusive treatment groups: polyethylene central-pegged ingrowth, polyethylene-metal hybrid, polyethylene all-cemented pegged, and polyethylene cemented keeled. Multivariable competing risk regression was used to evaluate the risk of glenoid loosening as a cause-specific revision by the glenoid component design. RESULTS Of the 5566 TSA included in the final cohort, 39.2% of glenoid implants were polyethylene central-pegged ingrowth, 31.1% were polyethylene-metal hybrid, 26.0% were polyethylene all-cemented pegged, and 3.6% were polyethylene cemented keeled. At 6-year final follow-up, 4.1% of TSA were revised for any cause, and 1.4% for glenoid loosening. Compared with the polyethylene central-pegged ingrowth design, no difference in glenoid loosening revision risk was observed for the polyethylene-metal hybrid design (hazard ratio [HR] = 1.15, 95% confidence interval [CI] = 0.42-3.20). However, both the polyethylene all-cemented pegged (HR = 2.48, 95% CI = 1.08-5.66) and polyethylene cemented keeled (HR = 3.84, 95% CI = 1.13-13.00) designs had higher risks for revision due to glenoid loosening. CONCLUSIONS We observed glenoid component designs to be associated with differential risks in revision due to glenoid loosening with polyethylene all-cemented pegged glenoids and polyethylene cemented keeled glenoids having higher risks when compared with polyethylene central-pegged ingrowth glenoids. Surgeons may want to consider the glenoid component design when performing anatomic TSA.
Collapse
Affiliation(s)
- Mark T Dillon
- Department of Orthopaedics, The Permanente Medical Group, Sacramento, CA, USA.
| | - Priscilla H Chan
- Surgical Outcomes and Analysis, Kaiser Permanente, San Diego, CA, USA
| | | | | | - Edward H Yian
- Department of Orthopaedics, Southern California Permanente Medical Group, Anaheim, CA, USA
| | - Anshuman Singh
- Department of Orthopaedics, Southern California Permanente Medical Group, San Diego, CA, USA
| | | | - Ronald A Navarro
- Department of Orthopaedics, Southern California Permanente Medical Group, Harbor City, CA, USA
| |
Collapse
|
18
|
Schoch BS, Zarezadeh A, Priddy M, King JJ, Wright TW. Uncemented fixation of a monoblock ingrowth polyethylene glenoid: early follow-up. J Shoulder Elbow Surg 2020; 29:968-975. [PMID: 31812586 DOI: 10.1016/j.jse.2019.09.034] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 06/07/2019] [Revised: 09/03/2019] [Accepted: 09/12/2019] [Indexed: 02/01/2023]
Abstract
BACKGROUND Traditional monoblock pegged glenoid components are implanted with cement, increasing operative time and potentially violating more bone than those inserted without cement. We study the early radiographic loosening and reoperation rate following uncemented fixation of a hybrid cage monoblock polyethylene glenoid component. METHODS Between 2013 and 2015, a total of 51 shoulders underwent anatomic shoulder arthroplasty (TSA) using a hybrid ingrowth cage polyethylene glenoid component by a single surgeon, with a minimum follow-up of 2 years. In all cases, the glenoid component was placed without cement. Mean follow-up was 33 months (range, 24-57). The primary outcome was Lazarus scale-assessed radiographic loosening. Secondary outcomes included reoperation, range of motion (ROM), and patient-reported outcome measures (PROMs). RESULTS Twelve glenoid components (24%) had radiolucent lines. Glenoid lines were rated grade 1, grade 2, and grade 5 (6, 4, and 2 shoulders, respectively). Six shoulders (12%) had humeral lucent lines. Two shoulders (4%) underwent reoperation, only 1 of these occurring due to isolated failure of the glenoid component. As a group, mean ROM and PROMs improved significantly compared with preoperative values and exceeded the minimal clinically important difference. CONCLUSION Glenoid loosening remains a major concern at mid- to long-term follow-up of TSA. Placement of this hybrid cage monoblock polyethylene glenoid component in a completely uncemented fashion does not lead to early clinical loosening, after which bony ingrowth into the central cage can be expected. Uncemented fixation of this hybrid cage component appears to be a safe treatment option for patients undergoing primary TSA.
Collapse
Affiliation(s)
- Bradley S Schoch
- Department of Orthopedic Surgery, Mayo Clinic, Jacksonville, FL, USA.
| | - Ali Zarezadeh
- Department Orthopaedic Surgery and Rehabilitation, University of Florida, Gainesville, FL, USA
| | - Michael Priddy
- Department Orthopaedic Surgery and Rehabilitation, University of Florida, Gainesville, FL, USA
| | - Joseph J King
- Department Orthopaedic Surgery and Rehabilitation, University of Florida, Gainesville, FL, USA
| | - Thomas W Wright
- Department Orthopaedic Surgery and Rehabilitation, University of Florida, Gainesville, FL, USA
| |
Collapse
|
19
|
Kim DM, Aldeghaither M, Alabdullatif F, Shin MJ, Kholinne E, Kim H, Jeon IH, Koh KH. Loosening and revision rates after total shoulder arthroplasty: a systematic review of cemented all-polyethylene glenoid and three modern designs of metal-backed glenoid. BMC Musculoskelet Disord 2020; 21:114. [PMID: 32085766 PMCID: PMC7035638 DOI: 10.1186/s12891-020-3135-6] [Citation(s) in RCA: 14] [Impact Index Per Article: 2.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 11/26/2019] [Accepted: 02/12/2020] [Indexed: 11/10/2022] Open
Abstract
BACKGROUND Several modern designs of metal-backed glenoids (MBG) have been devised to overcome flaws such as loosening and a high failure rate. This review aimed to compare rates of complications and revision surgeries between cemented polyethylene glenoid (PEG) and three examples of modern MBG designs. METHODS Literature search was carried out using PubMed, Cochrane Library, EMBASE, and Google Scholar using MeSH terms and natural keywords. A total of 1186 articles were screened. We descriptively analyzed numerical data between the groups and statistically analyzed the categorical data, such as the presence of radiolucent line, loosening, and revision surgery (failure). Articles were divided into three groups based on follow-up duration: < 36-month, 36-72-month, and > 72-month subgroups. RESULTS This study included 35 articles (3769 shoulders); 25 on cemented PEG and ten on the modern MBG. Mean age was 66.4 (21-93) and 66.5 years (31-88). The mean duration of follow-up was 73.1 (12-211) and 56.1 months (24-100). Overall, the rate of the radiolucent line was 354/1302 (27%) and 47/282 (17%), the loosening rate was 465/3185 (15%) and 22/449 (5%), and the failure rate was 189/3316 (6%) and 11/457 (2%), for PEG and MBG, respectively. The results of < 36-month and 36-72-month subgroups showed lower rates of radiolucency and loosening in the cemented PEG group, but there was no significant difference in failure rate (P = 0.754 and 0.829, respectively). In the > 72-month subgroup, MBG was better in terms of loosening (P < 0.001) and failure rates (P = 0.006). CONCLUSIONS The modern MBG component, especially TM glenoid, seems to be a promising alternative to cemented PEGs, based on subgroup revision rates according to the follow-up duration and overall results of ROM and clinical scores. All polyethylene glenoids tend to increase loosening and failure over time. Three modern MBG designs seem to have no difference in failure, at least in the < 36-month and 36-72-month subgroups compared to the cemented PEG. More long-term follow-up studies on modern MBG should be ultimately conducted. LEVEL OF EVIDENCE Level IV, systematic review.
Collapse
Affiliation(s)
- Dong Min Kim
- Department of Orthopaedic Surgery, Asan Medical Center, University of Ulsan College of Medicine, 88 Olympic-ro 43-gil, Songpa-gu, Seoul, 05535, South Korea
| | | | | | - Myung Jin Shin
- Department of Orthopaedic Surgery, Asan Medical Center, University of Ulsan College of Medicine, 88 Olympic-ro 43-gil, Songpa-gu, Seoul, 05535, South Korea
| | - Erica Kholinne
- Department of Orthopaedic Surgery, Asan Medical Center, University of Ulsan College of Medicine, 88 Olympic-ro 43-gil, Songpa-gu, Seoul, 05535, South Korea.,Department of Orthopaedic Surgery, St Carolus Hospital, Jakarta, Indonesia
| | - Hyojune Kim
- Department of Orthopaedic Surgery, Asan Medical Center, University of Ulsan College of Medicine, 88 Olympic-ro 43-gil, Songpa-gu, Seoul, 05535, South Korea
| | - In-Ho Jeon
- Department of Orthopaedic Surgery, Asan Medical Center, University of Ulsan College of Medicine, 88 Olympic-ro 43-gil, Songpa-gu, Seoul, 05535, South Korea
| | - Kyoung-Hwan Koh
- Department of Orthopaedic Surgery, Asan Medical Center, University of Ulsan College of Medicine, 88 Olympic-ro 43-gil, Songpa-gu, Seoul, 05535, South Korea.
| |
Collapse
|
20
|
Friedman RJ, Cheung E, Grey SG, Flurin PH, Wright TW, Zuckerman JD, Roche CP. Clinical and radiographic comparison of a hybrid cage glenoid to a cemented polyethylene glenoid in anatomic total shoulder arthroplasty. J Shoulder Elbow Surg 2019; 28:2308-2316. [PMID: 31324502 DOI: 10.1016/j.jse.2019.04.049] [Citation(s) in RCA: 22] [Impact Index Per Article: 3.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 02/19/2019] [Revised: 04/16/2019] [Accepted: 04/24/2019] [Indexed: 02/01/2023]
Abstract
BACKGROUND This study reports the clinical and radiographic outcomes of a hybrid cage glenoid compared with an age-matched, sex-matched, and follow-up-matched cohort of cemented all-polyethylene peg glenoids in patients undergoing anatomic total shoulder arthroplasty with 2 years' minimum follow-up. MATERIALS AND METHODS We reviewed 632 primary anatomic total shoulder arthroplasty patients from an international multi-institutional database; 316 patients received hybrid cage glenoids and were matched for age, sex, and follow-up with 316 patients with cemented all-polyethylene peg glenoids. Each cohort received the same humeral component. Scoring was performed in all patients preoperatively and at latest follow-up using 5 outcome scoring metrics and 4 active range-of-motion measurements. A Student 2-tailed unpaired t test identified differences in outcomes; P < .05 denoted a significant difference. RESULTS Cage glenoid patients had significantly lower rates of radiolucent glenoid lines (9.0% vs. 37.6%, P < .0001) and radiolucent humeral lines (3.0% vs. 9.1%, P = .0088) than all-polyethylene peg glenoid patients. In the cage glenoid cohort, 4 cases of aseptic glenoid loosening (1.3%) and 4 cases of articular surface dissociation (1.3%) occurred. In the all-polyethylene peg cohort, 12 cases of aseptic loosening (3.8%) occurred. Cage glenoid patients had a significantly lower revision rate than all-polyethylene peg glenoid patients (2.5% vs. 6.9%, P = .0088). CONCLUSION At 50 months' mean follow-up, cage glenoids demonstrated equally good clinical outcomes to all-polyethylene peg glenoids. Cage glenoids had significantly fewer radiolucent lines around both the glenoid and humeral components and a lower revision rate. Longer-term follow-up is required to confirm these promising short-term results.
Collapse
Affiliation(s)
- Richard J Friedman
- Department of Orthopaedics and Physical Medicine, Medical University of South Carolina, Charleston, SC, USA.
| | | | - Sean G Grey
- Orthopaedic & Spine Center of the Rockies, Fort Collins, CO, USA
| | | | - Thomas W Wright
- Department of Orthopaedics & Sports Medicine, University of Florida, Gainesville, FL, USA
| | | | | |
Collapse
|
21
|
Watson ST, Gudger GK, Long CD, Tokish JM, Tolan SJ. Outcomes of Trabecular Metal-backed glenoid components in anatomic total shoulder arthroplasty. J Shoulder Elbow Surg 2018; 27:493-498. [PMID: 29433646 DOI: 10.1016/j.jse.2017.09.036] [Citation(s) in RCA: 26] [Impact Index Per Article: 3.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 06/05/2017] [Revised: 09/22/2017] [Accepted: 09/30/2017] [Indexed: 02/01/2023]
Abstract
BACKGROUND As glenoid failure is one of the primary causes of failure of anatomic total shoulder arthroplasty (TSA), Trabecular Metal-backed glenoid components have become popular. This study reports implant survival and clinical outcomes of patients who received a Trabecular Metal-backed glenoid component during primary anatomic TSA. METHODS Patients who underwent TSA with a Trabecular Metal-backed glenoid component by a single surgeon were identified and reviewed for clinical, radiographic, and patient-reported outcome measures with a minimum of 2 years' follow-up. RESULTS Of 47 patients identified, radiographic and clinical follow-up was available on 36 patients (77%). Average age was 66.36 years (range, 50-85 years), and the average follow-up 41 months (range, 24-66 months). Three patients showed signs of osteolysis, 4 had radiographic evidence of metal debris, and 1 patient had a catastrophic failure after a fall. Of the 47 TSAs, 5 (11%) were revised to a reverse TSA for subscapularis failure and pain. Visual analog scale for pain scores improved by an average of 4.4. At final follow-up, the average Single Assessment Numeric Evaluation score was 72.4; Penn satisfaction score, 7.5; Penn score, 70.35; and American Shoulder and Elbow Surgeons score, 69.23. Outcome scores were similar in the 7 patients with osteolysis or metal debris compared to those without. CONCLUSION Trabecular Metal-backed glenoids had a 25% rate of radiographic metal debris and osteolysis at a minimum 2-year follow-up in this series with one catastrophic failure. This implant should be used with caution, and patients followed closely.
Collapse
Affiliation(s)
| | | | | | - John M Tokish
- Steadman Hawkins Clinic of the Carolinas, Greenville Health System, Greenville, SC, USA; Mayo Clinic Arizona, Scottsdale, AZ, USA.
| | - Stefan J Tolan
- Steadman Hawkins Clinic of the Carolinas, Greenville Health System, Greenville, SC, USA
| |
Collapse
|
22
|
Chamberlain AM, Aleem A, Keener JD. What's New in Shoulder and Elbow Surgery. J Bone Joint Surg Am 2017; 99:1780-1786. [PMID: 29040133 DOI: 10.2106/jbjs.17.00756] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 02/01/2023]
|
23
|
Gerscovich D, Schwing C, Unger A. Long-term results of a porous tantalum monoblock tibia component: clinical and radiographic results at follow-up of 10 years. Arthroplast Today 2017; 3:192-196. [PMID: 28913406 PMCID: PMC5585820 DOI: 10.1016/j.artd.2017.02.004] [Citation(s) in RCA: 15] [Impact Index Per Article: 1.9] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 09/24/2016] [Revised: 02/11/2017] [Accepted: 02/13/2017] [Indexed: 11/26/2022] Open
Abstract
Background The purpose of this study is to assess the long-term follow-up of cementless total knee arthroplasty with the trabecular metal (TM) monoblock tibial component at an average 10-year follow-up. This report is an extension of our previously reported series of 108 TM tibias reported in 2011 (Unger and Duggan, 2011). Methods Fifty-eight of the original 108 knees were available for review. Each follow-up patient was evaluated by radiologic and clinical Knee Society Scores. The average follow-up was 10.2 years. Results Our results indicate excellent long-term survivorship (96.5%) with 2 confirmed tibia revisions, and 1 femoral revision for periprosthetic fracture and 1 patella open reduction internal fixation. X-ray evaluation demonstrated one patient with 1 mm medial polyethylene wear and a nonprogressive 1 mm of radiolucency on the medial side. All the other tibial components showed full bone apposition and incorporation. Knee Society Scores were excellent in all the patients seen on follow-up. Conclusions Long-term follow-up of TM monoblock tibia components confirm excellent survivorship and biologic implant fixation, with excellent outcomes and knee scores.
Collapse
Affiliation(s)
- Daniel Gerscovich
- Department of Orthopedics, George Washington University, Washington, DC, USA
- Corresponding author. 2300 M St. NW, Washington, DC 20037, USA. Tel.: +1 202 741 3300.2300 M St. NWWashingtonDC20037USA
| | | | - Anthony Unger
- Department of Orthopedics, George Washington University, Washington, DC, USA
- Washington Orthopedics and Sports Medicine, Washington, DC, USA
| |
Collapse
|