1
|
Fekih-Zaghbib S, Dhaouadi S, Mejri H, Meftah M, Abderrazek H, Miled K, Benlasfar Z, Cherif N, Sadok S, Santulli A, Raouafi N, Bouhaouala-Zahar B. A label-free electrochemical biosensor for rapid quantification of antimicrobial peptides in teleost fish mucus. J Pharm Biomed Anal 2025; 258:116749. [PMID: 39985922 DOI: 10.1016/j.jpba.2025.116749] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/28/2024] [Revised: 01/28/2025] [Accepted: 02/13/2025] [Indexed: 02/24/2025]
Abstract
We used a thiol-faradaic electrochemical differential pulse voltammetry and impedance spectroscopy on a gold-modified screen-printed carbon electrode to quantify Chrysophsins antimicrobial peptides in the fish mucus without prior extraction. We have developed a specific anti-Chrysophsins polyclonal antibody and used ferrocene as a transducing system. The platform has a sensitivity of 30.5 nA.mL.ng-1 (11.28 nA.nM-1) in a linear range of 0.1-1 µg.mL-1 and a limit of detection of 0.227 ng.mL-1 (84.15 pM). Selectivity, accuracy, repeatability and stability were validated to meet the guidelines of ligand binding assays. Mean Chrysophsins levels in mucus pools from healthy and thermally unstressed Argyrosomus regius, Dicentrarchus labrax and Sparus aurata fish were 8.763 µM (± 0.007), 7.296 µM (± 0.023) and 8.296 (± 0.044) respectively, within the range of mass spectrometry gill values and below the minimum inhibitory concentration (MIC) of Chrysophsins for fish pathogens. The multi-infected D. labrax pool shows a significant decrease in concentration compared to the healthy and thermally stressed pools (p < 0.0262) with 2.8 µM (± 0.024). The thermally stressed A. regius pool is not significantly different from the other pools with 8.763 µM (± 0.007). This electrochemical platform is a flexible tool for real-time targeting of peptide biomarkers in the real matrix and is suitable for mucosal fluids for early fish welfare monitoring.
Collapse
Affiliation(s)
- Sonia Fekih-Zaghbib
- NanoBioMedika Research Team, Laboratoire des Biomolécules, Venins et Applications Théranostiques (LR20IPT01), Institut Pasteur de Tunis, Université Tunis-El Manar, Tunisia.
| | - Sayda Dhaouadi
- NanoBioMedika Research Team, Laboratoire des Biomolécules, Venins et Applications Théranostiques (LR20IPT01), Institut Pasteur de Tunis, Université Tunis-El Manar, Tunisia
| | - Hiba Mejri
- NanoBioMedika Research Team, Laboratoire des Biomolécules, Venins et Applications Théranostiques (LR20IPT01), Institut Pasteur de Tunis, Université Tunis-El Manar, Tunisia
| | - Marwa Meftah
- Sensors and Biosensors Group, ACE-Lab (LR99ES15), Faculty of Science, University of Tunis El Manar, Tunis El Manar 2092, Tunisia
| | - Houyem Abderrazek
- Laboratoire des Matériaux Utiles, National Institute of Research and Physicochemical Analysis, BiotechPole of Sidi Thabet, Tunisia
| | - Khaled Miled
- NanoBioMedika Research Team, Laboratoire des Biomolécules, Venins et Applications Théranostiques (LR20IPT01), Institut Pasteur de Tunis, Université Tunis-El Manar, Tunisia
| | - Zakaria Benlasfar
- NanoBioMedika Research Team, Laboratoire des Biomolécules, Venins et Applications Théranostiques (LR20IPT01), Institut Pasteur de Tunis, Université Tunis-El Manar, Tunisia
| | - Nadia Cherif
- Aquaculture Laboratory, National Institute of Marine Sciences and technologies, University of Tunis El Manar, Tunisia
| | - Saloua Sadok
- Blue Biotechnology and Aquatic Bioproducts Laboratory, National Institute of Marine Sciences and technologies, University of Tunis El Manar, Tunisia
| | - Andrea Santulli
- Dipartimento di Scienze della terra e del Mare DiSTeM, Laboratorio di Biochimica Marina ed Ecotossicologia, Università degli Studi di Palermo, Via G. Barlotta 4, Trapani 91100, Italy.
| | - Noureddine Raouafi
- Sensors and Biosensors Group, ACE-Lab (LR99ES15), Faculty of Science, University of Tunis El Manar, Tunis El Manar 2092, Tunisia
| | - Balkiss Bouhaouala-Zahar
- NanoBioMedika Research Team, Laboratoire des Biomolécules, Venins et Applications Théranostiques (LR20IPT01), Institut Pasteur de Tunis, Université Tunis-El Manar, Tunisia; Faculté de Médecine de Tunis, Université Tunis el Manar, Tunis, Tunisia.
| |
Collapse
|
2
|
Rajaei SN, Darvish M, Zare A, Abdollahi H, Alivirdiloo V, Hajiabbasi M, Ghazi F, Mobed A. Advances in Nanobiosensors for Rapid and Sensitive Detection of Dengue Virus Biomarkers by Using Clinical Laboratory. J Clin Lab Anal 2025; 39:e70012. [PMID: 40079489 PMCID: PMC11981959 DOI: 10.1002/jcla.70012] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/09/2024] [Revised: 01/26/2025] [Accepted: 02/21/2025] [Indexed: 03/15/2025] Open
Abstract
BACKGROUND The recent rise in dengue virus (DENV) cases poses a significant threat to human health, with infections ranging from mild to severe and potentially leading to premature death. OBJECTIVE To highlight the importance of early detection of DENV and to review advancements in detection technologies, particularly focusing on nanobiosensors. METHODS This review examines traditional detection methods for DENV, including molecular, serological, and direct virus culture techniques, while discussing their limitations. It also explores innovative technologies that enhance detection accuracy, speed, and efficiency. RESULTS Nonstructural protein 1 (NS1) serves as a key biomarker present in high concentrations during the early stages of DENV infection, underscoring the need for timely detection. Traditional methods, while effective, have limitations that new technologies aim to address. Biosensors, particularly nanobiosensors, have emerged as promising tools for rapid, sensitive, and cost-effective DENV detection. CONCLUSION The adoption of advanced detection methods, especially nanobiosensors, is crucial for improving DENV management and reducing human suffering. This review provides a comprehensive overview of nanobiosensors and their applications, presented in an accessible manner for readers.
Collapse
Affiliation(s)
| | - Mohammad Darvish
- School of Aerospace and Subaquatic Medicine, Infectious Diseases & Tropical Medicine Research Center(IDTMC)AJA University of Medical SciencesTehranIran
| | - Alireza Zare
- Shiraz University of Medical SciencesFaculty of MedicineShirazIran
| | - Hamed Abdollahi
- Department of Parasitology, School of MedicineAhvaz Jundishapur University of Medical SciencesAhvazKhuzestanIran
| | - Vahid Alivirdiloo
- Medical Doctor Department of Physiology and PharmacologyMazandaran University of Medical SciencesRamsarIran
| | | | - Farhood Ghazi
- Clinical Research Development Unit of Tabriz Valiasr HospitalTabriz University of Medical SciencesTabrizIran
| | - Ahmad Mobed
- Social Determinants of Health Research CenterHealth Management and Safety PromotionIran
| |
Collapse
|
3
|
Paliwal P, Desai D, Datta M. Novel selective and sensitive electrochemical sensor for detection of ovarian cancer biomarker, Cathepsin L. Bioelectrochemistry 2025; 162:108856. [PMID: 39581047 DOI: 10.1016/j.bioelechem.2024.108856] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/30/2024] [Revised: 11/15/2024] [Accepted: 11/19/2024] [Indexed: 11/26/2024]
Abstract
Late detection of ovarian cancer is critical as it results in decreased life expectancy of patients. Screening methodology with a rapid turnover is required to ensure better patient outcomes. Till date, no point of care diagnostics exists capable of monitoring epithelial ovarian cancer. Cathepsin L is a classic early-stage biomarker demarcating the proliferation and transition of ovarian cancer. A novel label-free electrochemical diagnostic is proposed for detection of Cathepsin L in serum. Intrinsic fluorescence spectroscopy was used to confirm the interaction between Cathepsin L and probe, Cystatin C. Cystatin C was immobilized on screen-printed carbon electrode using 1-Ethyl-3-(3-dimethyl-aminopropyl carbodiimide and N-hydroxysuccinimide cross linker. Electrochemical fluctuations resulting from Cystatin-Cathepsin interaction was detected by cyclic voltammetry, differential voltammetry and electrochemical impedance spectroscopy within a timeframe of 20 min. The proposed diagnostic for Cathepsin L exhibited analytical performance with a limit of detection upto 70 pg mL-1 via electrochemical impedance spectroscopy in the dynamic detection range of 2 ng mL-1-20 ng mL-1. The platform indicated reliable reproducibility, selectivity, and stability. Furthermore, validation with spiked sera samples (n = 5) showed correlation of R2 = 0.98. The results indicate sensitive yet selective point of care diagnosis of Cathepsin L in serum.
Collapse
Affiliation(s)
- Priya Paliwal
- Amity Institute of Biotechnology, Amity University, Rajasthan 303002, India
| | - Dignya Desai
- Catalent Pharmasolutions, Somerset, NJ 008873, USA
| | - Manali Datta
- Amity Institute of Biotechnology, Amity University, Rajasthan 303002, India.
| |
Collapse
|
4
|
Tewari M, Rana P, Pande V. Nanomaterial-Based Biosensors for the Detection of COVID-19. Indian J Microbiol 2025; 65:120-136. [PMID: 40371045 PMCID: PMC12069788 DOI: 10.1007/s12088-024-01336-0] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/17/2024] [Accepted: 06/12/2024] [Indexed: 05/16/2025] Open
Abstract
The COVID-19 outbreak began in December 2019 and has affected people worldwide. It was declared a pandemic in 2020 by the World Health Organization. Developing rapid and reliable diagnostic techniques is crucial for identifying COVID-19 early and preventing the disease from becoming severe. In addition to conventional diagnostic techniques such as RT-PCR, computed tomography, serological assays, and sequencing methods, biosensors have become widely accepted for identifying and screening COVID-19 infection with high accuracy and sensitivity. Their low cost, high sensitivity, specificity, and portability make them ideal for diagnostics. The use of nanomaterials improves the performance of biosensors by increasing their sensitivities and limiting detection by several orders of magnitude. This manuscript briefly reviews the COVID-19 outbreak and its pathogenesis. Furthermore, it comprehensively discusses the currently available biosensors for SARS-CoV-2 detection, with a special emphasis on nanomaterials-based biosensors developed to detect this emerging virus and its variants efficiently.
Collapse
Affiliation(s)
- Manju Tewari
- Department of Biotechnology, Kumaun University, Sir J.C. Bose Technical Campus, Bhimtal, Uttarakhand 263136 India
| | - Prerna Rana
- Department of Biotechnology, Kumaun University, Sir J.C. Bose Technical Campus, Bhimtal, Uttarakhand 263136 India
| | - Veena Pande
- Department of Biotechnology, Kumaun University, Sir J.C. Bose Technical Campus, Bhimtal, Uttarakhand 263136 India
| |
Collapse
|
5
|
Blázquez AB, Jiménez de Oya N. Biosensors for the detection of flaviviruses: A review. Synth Syst Biotechnol 2024; 10:194-206. [PMID: 39552759 PMCID: PMC11564047 DOI: 10.1016/j.synbio.2024.10.005] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/27/2024] [Revised: 09/26/2024] [Accepted: 10/21/2024] [Indexed: 11/19/2024] Open
Abstract
Flaviviruses affect the lives of millions of people in endemic regions and also have the potential to impact non-endemic areas. Factors such as climate change, global warming, deforestation, and increased travel and trade are linked to the spread of flaviviruses into new habitats and host species. Given the absence of specific treatments and the limited availability of vaccines, it is imperative to understand the biology of flaviviruses and develop rapid and sensitive diagnostic tests. These measures are essential for preventing the transmission of these potentially life-threatening pathogens. Flavivirus infections are mainly diagnosed using conventional methods. However, these techniques present several drawbacks, including high expenses, time-consuming procedures, and the need for skilled professionals. The search for fast, easy-to-use, and affordable alternative techniques as a feasible solution for developing countries is leading to the search for new methods in the diagnosis of flaviviruses, such as biosensors. This review provides a comprehensive overview of different biosensor detection strategies for flaviviruses and describes recent advances in diagnostic technologies. Finally, we explore their future prospects and potential applications in pathogen detection. This review serves as a valuable resource to understand advances in ongoing research into new biosensor-based diagnostic methods for flaviviruses.
Collapse
Affiliation(s)
- Ana-Belén Blázquez
- Departamento de Biotecnología, Instituto Nacional de Investigación y Tecnología Agraria y Alimentaria (INIA-CSIC), Ctra. de La Coruña, km 7.5, 28040 Madrid, Spain
| | - Nereida Jiménez de Oya
- Departamento de Biotecnología, Instituto Nacional de Investigación y Tecnología Agraria y Alimentaria (INIA-CSIC), Ctra. de La Coruña, km 7.5, 28040 Madrid, Spain
| |
Collapse
|
6
|
Wu D, Zhu J, Zheng Y, Fu L. Electrochemical Sensing Strategies for Synthetic Orange Dyes. Molecules 2024; 29:5026. [PMID: 39519667 PMCID: PMC11547196 DOI: 10.3390/molecules29215026] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/30/2024] [Revised: 10/16/2024] [Accepted: 10/22/2024] [Indexed: 11/16/2024] Open
Abstract
This review explores electrochemical sensing strategies for synthetic orange dyes, addressing the growing need for sensitive and selective detection methods in various industries. We examine the fundamental principles underlying the electrochemical detection of these compounds, focusing on their redox behavior and interaction with electrode surfaces. The review covers a range of sensor designs, from unmodified electrodes to advanced nanomaterial-based platforms. Chemically modified electrodes incorporating polymers and molecularly imprinted polymers are discussed for their enhanced selectivity. Particular attention is given to nanomaterial-based sensors, including those utilizing carbon nanotubes, graphene derivatives, and metal nanoparticles, which have demonstrated exceptional sensitivity and wide linear ranges. The potential of biological-based approaches, such as DNA interaction sensors and immunosensors, is also evaluated. Current challenges in the field are addressed, including matrix effects in complex samples and long-term stability issues. Emerging trends are highlighted, including the development of multi-modal sensing platforms and the integration of artificial intelligence for data analysis. The review concludes by discussing the commercial potential of these sensors in food safety, environmental monitoring, and smart packaging applications, emphasizing their importance in ensuring the safe use of synthetic orange dyes across industries.
Collapse
Affiliation(s)
- Dihua Wu
- College of Materials and Environmental Engineering, Hangzhou Dianzi University, Hangzhou 310018, China;
| | - Jiangwei Zhu
- Co-Innovation Center for Sustainable Forestry in Southern China, Nanjing Forestry University, Nanjing 210037, China;
| | - Yuhong Zheng
- Institute of Botany, Jiangsu Province and Chinese Academy of Sciences, Nanjing Botanical Garden, Memorial Sun Yat-Sen, Nanjing 210014, China;
- Jiangsu Key Laboratory for the Research and Utilization of Plant Resources, Nanjing 210014, China
| | - Li Fu
- College of Materials and Environmental Engineering, Hangzhou Dianzi University, Hangzhou 310018, China;
| |
Collapse
|
7
|
Khanal S, Pillai M, Biswas D, Torequl Islam M, Verma R, Kuca K, Kumar D, Najmi A, Zoghebi K, Khalid A, Mohan S. A paradigm shift in the detection of bloodborne pathogens: conventional approaches to recent detection techniques. EXCLI JOURNAL 2024; 23:1245-1275. [PMID: 39574968 PMCID: PMC11579516 DOI: 10.17179/excli2024-7392] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Figures] [Subscribe] [Scholar Register] [Received: 05/15/2024] [Accepted: 09/04/2024] [Indexed: 11/24/2024]
Abstract
Bloodborne pathogens (BBPs) pose formidable challenges in the realm of infectious diseases, representing significant risks to both human and animal health worldwide. The review paper provides a thorough examination of bloodborne pathogens, highlighting the serious worldwide threat they pose and the effects they have on animal and human health. It addresses the potential dangers of exposure that healthcare workers confront, which have affected 3 million people annually, and investigates the many pathways by which these viruses can spread. The limitations of traditional detection techniques like PCR and ELISA have been criticized, which has led to the investigation of new detection methods driven by advances in sensor technology. The objective is to increase the amount of knowledge that is available regarding bloodborne infections as well as effective strategies for their management and detection. This review provides a thorough overview of common bloodborne infections, including their patterns of transmission, and detection techniques.
Collapse
Affiliation(s)
- Sonali Khanal
- School of Bioengineering and Food Technology, Shoolini University of Biotechnology and Management Sciences, Solan 173229, India
| | - Manjusha Pillai
- School of Bioengineering and Food Technology, Shoolini University of Biotechnology and Management Sciences, Solan 173229, India
| | - Deblina Biswas
- Instrumentation and Control Engineering, Dr. B. R. Ambedkar National Institute of Technology Jalandhar, Punjab, 144011, India
| | - Muhammad Torequl Islam
- Department of Pharmacy, Bangabandhu Sheikh Mujibur Rahman Science and Technology University, Gopalganj 8100, Bangladesh
- Department of Pharmacy, Bangabandhu Sheikh Mujibur Rahman Science and Technology University, Gopalgonj 8100, Bangladesh
- Bioinformatics and Drug Innovation Laboratory, BioLuster Research Center Ltd., Gopalganj 8100, Bangladesh
| | - Rachna Verma
- School of Biological and Environmental Sciences, Shoolini University of Biotechnology and Management Sciences, Solan 173229, India
- Faculty of Science, University of Hradec Kralove, Rokitanskeho 62, 500 03 Hradec Kralove, Czech Republic
| | - Kamil Kuca
- Faculty of Science, University of Hradec Kralove, Rokitanskeho 62, 500 03 Hradec Kralove, Czech Republic
- Biomedical Research Center, University Hospital Hradec Kralove, 50003 Hradec Kralove, Czech Republic
- Center for Advanced Innovation Technologies, VSB-Technical University of Ostrava,70800, Ostrava-Poruba, Czech Republic
| | - Dinesh Kumar
- School of Bioengineering and Food Technology, Shoolini University of Biotechnology and Management Sciences, Solan 173229, India
| | - Asim Najmi
- Department of Pharmaceutical Chemistry and Pharmacognosy, College of Pharmacy, Jazan University, Jazan 45142, Saudi Arabia
| | - Khalid Zoghebi
- Department of Pharmaceutical Chemistry and Pharmacognosy, College of Pharmacy, Jazan University, Jazan 45142, Saudi Arabia
| | - Asaad Khalid
- Health Research Center, Jazan University, P. O. Box 114, Jazan, 82511, Saudi Arabia
| | - Syam Mohan
- Center for Global Health Research, Saveetha Medical College and Hospitals, Saveetha Institute of Medical and Technical Sciences, Saveetha University, India
- School of Health Sciences, University of Petroleum and Energy Studies, Dehradun, Uttarakhand, India
| |
Collapse
|
8
|
Wang X, Qin Z, Zhang F, Li C, Yuan X, Yang J, Yang H. Label-free electrochemical biosensor based on dual amplification of gold nanoparticles and polycaprolactones for CEA detection. Talanta 2024; 278:126468. [PMID: 38963975 DOI: 10.1016/j.talanta.2024.126468] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/10/2023] [Revised: 06/17/2024] [Accepted: 06/22/2024] [Indexed: 07/06/2024]
Abstract
Carcinoembryonic Antigen (CEA), an acidic glycoprotein with human embryonic antigen properties, is found on the surface of cancer cells that have differentiated from endodermal cells. This paper presents a label-free electrochemical immunoassay for the dual amplification detection of CEA using gold nanoparticles loaded with polypyrrole polydopamine (Au/PPy-PDA) and polymerized polycaprolactone (Ng-PCL) prepared by ring-opening polymerization (ROP). First, the composite Au/PPy-PDA was adhered to the electrode surface. Then, gold nanoparticles form a Au-S bond with the sulfhydryl group in Apt1 to secure it on the electrode surface. Subsequently, the non-specific binding sites on the electrodes surface are closed by bovine serum albumin (BSA). Next, CEA is dropped onto the electrode surface, which is immobilized by antigen-antibody specific recognition, and the carboxyl-functionalized Apt2 forms a "sandwich structure" of antibody-antigen-antibody by specific recognition. Polymeric Ng-PCL is adhered to the electrode surface, leading to an increase in the electrochemical impedance signal, resulting in a complete chain of signal analysis. Finally, the response signal is detected by electrochemical impedance spectroscopy (EIS). Under optimal experimental conditions, the method has the advantages of high sensitivity and wide linear range (1 pg mL-1∼100 ng mL-1), and the lower limit of detection (LOD) is 0.234 pg mL-1. And it has the same high sensitivity, selectivity and interference resistance for the real samples detection. Thus, it provides a new way of thinking about biomedical and clinical diagnosis.
Collapse
Affiliation(s)
- Xia Wang
- College of Pharmacy, Henan University of Chinese Medicine, Zhengzhou, 450046, PR China.
| | - Zhe Qin
- College of Pharmacy, Henan University of Chinese Medicine, Zhengzhou, 450046, PR China
| | - Fei Zhang
- College of Pharmacy, Henan University of Chinese Medicine, Zhengzhou, 450046, PR China.
| | - Chong Li
- College of Pharmacy, Henan University of Chinese Medicine, Zhengzhou, 450046, PR China
| | - Xianxian Yuan
- College of Pharmacy, Henan University of Chinese Medicine, Zhengzhou, 450046, PR China
| | - Jing Yang
- College of Pharmacy, Henan University of Chinese Medicine, Zhengzhou, 450046, PR China
| | - Huaixia Yang
- College of Pharmacy, Henan University of Chinese Medicine, Zhengzhou, 450046, PR China
| |
Collapse
|
9
|
Gao Y, Wang X, Fan C. Advances in graphene-based 2D materials for tendon, nerve, bone/cartilage regeneration and biomedicine. iScience 2024; 27:110214. [PMID: 39040049 PMCID: PMC11261022 DOI: 10.1016/j.isci.2024.110214] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 07/24/2024] Open
Abstract
Two-dimensional (2D) materials, especially graphene-based materials, have important implications for tissue regeneration and biomedicine due to their large surface area, transport properties, ease of functionalization, biocompatibility, and adsorption capacity. Despite remarkable progress in the field of tissue regeneration and biomedicine, there are still problems such as unclear long-term stability, lack of in vivo experimental data, and detection accuracy. This paper reviews recent applications of graphene-based materials in tissue regeneration and biomedicine and discusses current issues and prospects for the development of graphene-based materials with respect to promoting the regeneration of tendons, neuronal cells, bone, chondrocytes, blood vessels, and skin, as well as applications in sensing, detection, anti-microbial activity, and targeted drug delivery.
Collapse
Affiliation(s)
- Yuxin Gao
- Department of Orthopedics, Shanghai Sixth People’s Hospital Affiliated to Shanghai Jiao Tong University School of Medicine, Shanghai, China
- College of Fisheries and Life Science, Shanghai Ocean University, Shanghai, China
| | - Xu Wang
- Department of Orthopedics, Shanghai Sixth People’s Hospital Affiliated to Shanghai Jiao Tong University School of Medicine, Shanghai, China
- National Center for Orthopaedics, Shanghai, China
- Shanghai Engineering Research Center for Orthopaedic Material Innovation and Tissue Regeneration, Shanghai, China
| | - Cunyi Fan
- Department of Orthopedics, Shanghai Sixth People’s Hospital Affiliated to Shanghai Jiao Tong University School of Medicine, Shanghai, China
- National Center for Orthopaedics, Shanghai, China
- Shanghai Engineering Research Center for Orthopaedic Material Innovation and Tissue Regeneration, Shanghai, China
| |
Collapse
|
10
|
Muslihati A, Septiani NLW, Gumilar G, Nugraha N, Wasisto HS, Yuliarto B. Peptide-Based Flavivirus Biosensors: From Cell Structure to Virological and Serological Detection Methods. ACS Biomater Sci Eng 2024; 10:2041-2061. [PMID: 38526408 DOI: 10.1021/acsbiomaterials.3c01965] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 03/26/2024]
Abstract
In tropical and developing countries, mosquito-borne diseases by flaviviruses pose a serious threat to public health. Early detection is critical for preventing their spread, but conventional methods are time-consuming and require skilled technicians. Biosensors have been developed to address this issue, but cross-reactivity with other flaviviruses remains a challenge. Peptides are essentially biomaterials used in diagnostics that allow virological and serological techniques to identify flavivirus selectively. This biomaterial originated as a small protein consisting of two to 50 amino acid chains. They offer flexibility in chemical modification and can be easily synthesized and applied to living cells in the engineering process. Peptides could potentially be developed as robust, low-cost, sensitive, and selective receptors for detecting flaviviruses. However, modification and selection of the receptor agents are crucial to determine the effectiveness of binding between the targets and the receptors. This paper addresses two potential peptide nucleic acids (PNAs) and affinity peptides that can detect flavivirus from another target-based biosensor as well as the potential peptide behaviors of flaviviruses. The PNAs detect flaviviruses based on the nucleotide base sequence of the target's virological profile via Watson-Crick base pairing, while the affinity peptides sense the epitope or immunological profile of the targets. Recent developments in the functionalization of peptides for flavivirus biosensors are explored in this Review by division into electrochemical, optical, and other detection methods.
Collapse
Affiliation(s)
- Atqiya Muslihati
- Doctoral Program of Engineering Physics, Faculty of Industrial Technology, Institut Teknologi Bandung, Ganesha 10, Bandung 40132, Indonesia
- Advanced Functional Material Laboratory, Faculty of Industrial Technology, Institut Teknologi Bandung, Jl. Ganesha No. 10, Bandung 41032, Indonesia
- PT Biostark Analitika Inovasi, Bandung 40375, Indonesia
| | - Ni Luh Wulan Septiani
- Advanced Functional Material Laboratory, Faculty of Industrial Technology, Institut Teknologi Bandung, Jl. Ganesha No. 10, Bandung 41032, Indonesia
- Research Center for Nanotechnology Systems, National Research and Innovation Agency (BRIN), Kawasan Puspiptek, South Tangerang 15134, Indonesia
| | - Gilang Gumilar
- Research Center for Electronics, National Research and Innovation Agency (BRIN), Bandung 40135, Indonesia
| | - Nugraha Nugraha
- Advanced Functional Material Laboratory, Faculty of Industrial Technology, Institut Teknologi Bandung, Jl. Ganesha No. 10, Bandung 41032, Indonesia
- Research Center for Nanosciences and Nanotechnology (RCNN), Institut Teknologi Bandung, Jl. Ganesha No. 10, Bandung 41032, Indonesia
| | | | - Brian Yuliarto
- Advanced Functional Material Laboratory, Faculty of Industrial Technology, Institut Teknologi Bandung, Jl. Ganesha No. 10, Bandung 41032, Indonesia
- Research Center for Nanosciences and Nanotechnology (RCNN), Institut Teknologi Bandung, Jl. Ganesha No. 10, Bandung 41032, Indonesia
| |
Collapse
|
11
|
Thakur A, Kumar A. Exploring the potential of ionic liquid-based electrochemical biosensors for real-time biomolecule monitoring in pharmaceutical applications: From lab to life. RESULTS IN ENGINEERING 2023; 20:101533. [DOI: 10.1016/j.rineng.2023.101533] [Citation(s) in RCA: 2] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 01/03/2025]
|
12
|
Brandão STR, Dos Santos A, Bueno PR, Cilli EM. Designing Quantum Capacitive Peptide Interfaces for Electroanalytical Applications. Anal Chem 2023; 95:13470-13477. [PMID: 37647515 DOI: 10.1021/acs.analchem.3c01363] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 09/01/2023]
Abstract
Redox-active moieties assembled on metallic interfaces have been shown to follow quantum mechanical rules, where the quantum capacitance of the interface (directly associated with the electronic structure of the redox-active moieties) plays a key role in the electron transfer dynamics of the interface. Modifying these interfaces with biological receptors has significant advantages (simplifying molecular diagnostics methods, reducing size, time, and cost while maintaining high sensitivity), enabling the fabrication of miniaturized electroanalytical devices that can compete with traditional ELISA and RT-PCR benchtop assay methods. Owing to their intrinsic characteristics, the use of peptide-based redox-active moieties is a promising chemical route for modifying metallic surfaces, resulting in a high quantum capacitive signal sensitivity. In the present work, different ferrocene-tagged peptides with a structure of Fc-Glu-XX-XX-Cys-NH2 (XX = serine, phenylalanine, glycine) were used to form self-assembled monolayers on gold. The feasibility of using these interfaces in an electroanalytical assay was verified by detecting the NS1 DENV (Dengue Virus) biomarker to compare the efficiency of peptide structures for biosensing purposes. Parameters such as the formal potential of the interface, normalized electronic density of states (DOS), quantum capacitance, and electron transfer rate constants were obtained for Ser-, Phe-, and Gly-peptides. The Gly-peptide structure presented the highest analytical performance for sensing NS1 with a sensitivity of 5.6% per decade and the lowest LOD (1.4 ng mL-1) and LOQ (2.6 ng mL-1), followed by Phe-peptide, whereas Ser-peptide had the lowest performance. This work demonstrates that the use of peptides to fabricate a self-assembled monolayer as a biosensor component has advantages for low-cost point-of-care diagnostics. It also shows that the performance of the sensing interface depends strongly on how the chemistry of the surface is designed as a whole, not only on the redox-active group.
Collapse
Affiliation(s)
- Sarah T R Brandão
- Institute of Chemistry, São Paulo State University (UNESP), 14800-060 Araraquara, São Paulo, Brazil
| | - Adriano Dos Santos
- Institute of Chemistry, São Paulo State University (UNESP), 14800-060 Araraquara, São Paulo, Brazil
| | - Paulo R Bueno
- Institute of Chemistry, São Paulo State University (UNESP), 14800-060 Araraquara, São Paulo, Brazil
| | - Eduardo M Cilli
- Institute of Chemistry, São Paulo State University (UNESP), 14800-060 Araraquara, São Paulo, Brazil
| |
Collapse
|
13
|
Roberts A, Dhanze H, Sharma GT, Gandhi S. Point-of-care detection of Japanese encephalitis virus biomarker in clinical samples using a portable smartphone-enabled electrochemical "Sensit" device. Bioeng Transl Med 2023; 8:e10506. [PMID: 37206199 PMCID: PMC10189466 DOI: 10.1002/btm2.10506] [Citation(s) in RCA: 5] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/17/2023] [Revised: 03/02/2023] [Accepted: 03/04/2023] [Indexed: 05/21/2023] Open
Abstract
Japanese encephalitis (JE), a neglected tropical zoonotic disease prevalent in south-east Asian and western pacific countries, caused by the flavivirus JE virus (JEV), has a dearth of electrochemical point-of-care (PoC) diagnostic tools available to manage endemic breakouts. To overcome this, we have developed a screen-printed carbon electrode (SPCE) immunosensor for rapid PoC detection of JEV nonstructural 1 (NS1) antigen (Ag), found circulating in serum of infected individuals using a smartphone based portable "Sensit" device. The modification of SPCE surface with JEV NS1 antibody (Ab) was confirmed via observation of globular protein structures via scanning electron microscopy (SEM), increase in electrode surface hydrophilicity via contact angle measurement and decrease in current via differential pulse voltammetry (DPV). The fabrication and testing parameters were optimized based on highest current output obtained using DPV. The SPCE was tested for detection limit of target JEV NS1 Ag ranging from 1 fM to 1 μM, which was determined as 0.45 fM in spiked serum. The disposable immunosensor was also found to be highly specific in detecting JEV NS1 Ag over other flaviviral NS1 Ag. Finally, the modified SPCE was clinically validated by testing 62 clinical JEV samples using both a portable miniaturized electrochemical "Sensit" device coupled with a smartphone and a laboratory-based potentiostat. The results were corroborated with gold-standard RT-PCR and showed 96.77% accuracy, 96.15% sensitivity, and 97.22% specificity. Hence, this technique may further be developed into a one-step rapid diagnostic tool for JEV, especially in rural areas.
Collapse
Affiliation(s)
- Akanksha Roberts
- DBT‐National Institute of Animal Biotechnology (NIAB)HyderabadTelanganaIndia
- DBT‐Regional Centre for Biotechnology (RCB)FaridabadHaryanaIndia
| | - Himani Dhanze
- ICAR‐Indian Veterinary Research Institute (IVRI)IzatnagarUttar PradeshIndia
| | - G. Taru Sharma
- DBT‐National Institute of Animal Biotechnology (NIAB)HyderabadTelanganaIndia
- DBT‐Regional Centre for Biotechnology (RCB)FaridabadHaryanaIndia
| | - Sonu Gandhi
- DBT‐National Institute of Animal Biotechnology (NIAB)HyderabadTelanganaIndia
- DBT‐Regional Centre for Biotechnology (RCB)FaridabadHaryanaIndia
| |
Collapse
|
14
|
Gupta N, Kumar D, Das A, Sood S, Malhotra BD. Conductive Ink-Coated Paper-Based Supersandwich DNA Biosensor for Ultrasensitive Detection of Neisseria gonorrhoeae. BIOSENSORS 2023; 13:bios13040486. [PMID: 37185561 PMCID: PMC10136323 DOI: 10.3390/bios13040486] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 02/28/2023] [Revised: 04/13/2023] [Accepted: 04/14/2023] [Indexed: 05/17/2023]
Abstract
Herein, we report results of the studies relating to the development of an impedimetric, magnetic bead-assisted supersandwich DNA hybridization assay for ultrasensitive detection of Neisseria gonorrhoeae, the causative agent of a sexually transmitted infection (STI), gonorrhea. First, a conductive ink was formulated by homogenously dispersing carboxylated multiwalled carbon nanotubes (cMWCNTs) in a stable emulsion of terpineol and an aqueous suspension of carboxymethyl cellulose (CMC). The ink, labeled C5, was coated onto paper substrates to fabricate C5@paper conductive electrodes. Thereafter, a magnetic bead (MB)-assisted supersandwich DNA hybridization assay was optimized against the porA pseudogene of N. gonorrhoeae. For this purpose, a pair of specific 5' aminated capture probes (SCP) and supersandwich detector probes (SDP) was designed, which allowed the enrichment of target gonorrheal DNA sequence from a milieu of substances. The SD probe was designed such that instead of 1:1 binding, it allowed the binding of more than one T strand, leading to a 'ladder-like' DNA supersandwich structure. The MB-assisted supersandwich assay was integrated into the C5@paper electrodes for electrochemical analysis. The C5@paper electrodes were found to be highly conductive by a four-probe conductivity method (maximum conductivity of 10.1 S·cm-1). Further, the biosensing assay displayed a wide linear range of 100 aM-100 nM (109 orders of magnitude) with an excellent sensitivity of 22.6 kΩ·(log[concentration])-1. The clinical applicability of the biosensing assay was assessed by detecting genomic DNA extracted from N. gonorrhoeae in the presence of DNA from different non-gonorrheal bacterial species. In conclusion, this study demonstrates a highly sensitive, cost-effective, and label-free paper-based device for STI diagnostics. The ink formulation prepared for the study was found to be highly thixotropic, which indicates that the paper electrodes can be screen-printed in a reproducible and scalable manner.
Collapse
Affiliation(s)
- Niharika Gupta
- Department of Biotechnology, Delhi Technological University, Delhi 110042, India
| | - D Kumar
- Department of Applied Chemistry, Delhi Technological University, Delhi 110042, India
| | - Asmita Das
- Department of Biotechnology, Delhi Technological University, Delhi 110042, India
| | - Seema Sood
- Department of Microbiology, All India Institute of Medical Sciences, Ansari Nagar, New Delhi 110016, India
| | - Bansi D Malhotra
- Department of Biotechnology, Delhi Technological University, Delhi 110042, India
| |
Collapse
|
15
|
Ang PC, Perumal V, Ibrahim MNM, Adnan R, Mohd Azman DK, Gopinath SCB, Raja PB. Electrochemical biosensor detection on respiratory and flaviviruses. Appl Microbiol Biotechnol 2023; 107:1503-1513. [PMID: 36719432 PMCID: PMC9887245 DOI: 10.1007/s00253-023-12400-y] [Citation(s) in RCA: 5] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/04/2022] [Revised: 01/14/2023] [Accepted: 01/18/2023] [Indexed: 02/01/2023]
Abstract
Viruses have spread throughout the world and cause acute illness or death among millions of people. There is a growing concern about methods to control and combat early-stage viral infections to prevent the significant public health problem. However, conventional detection methods like polymerase chain reaction (PCR) requires sample purification and are time-consuming for further clinical diagnosis. Hence, establishing a portable device for rapid detection with enhanced sensitivity and selectivity for the specific virus to prevent further spread becomes an urgent need. Many research groups are focusing on the potential of the electrochemical sensor to become a key for developing point-of-care (POC) technologies for clinical analysis because it can solve most of the limitations of conventional diagnostic methods. Herein, this review discusses the current development of electrochemical sensors for the detection of respiratory virus infections and flaviviruses over the past 10 years. Trends in future perspectives in rapid clinical detection sensors on viruses are also discussed. KEY POINTS: • Respiratory related viruses and Flavivirus are being concerned for past decades. • Important to differentiate the cross-reactivity between the virus in same family. • Electrochemical biosensor as a suitable device to detect viruses with high performance.
Collapse
Affiliation(s)
- Phaik Ching Ang
- School of Chemical Sciences, Universiti Sains Malaysia, 11800, Gelugor, Penang, Malaysia
| | - Veeradasan Perumal
- Centre of Innovative Nanostructures and Nanodevices (COINN), Universiti Teknologi PETRONAS (UTP), Seri Iskandar, Perak, Malaysia
- Mechanical Engineering Department, Universiti Teknologi PETRONAS (UTP), Seri Iskandar, Perak, Malaysia
| | | | - Rohana Adnan
- School of Chemical Sciences, Universiti Sains Malaysia, 11800, Gelugor, Penang, Malaysia
| | - Daruliza Kernain Mohd Azman
- Institute for Research in Molecular Medicine (INFORMM), Universiti Sains Malaysia, 11800, Penang, Gelugor, Malaysia
| | - Subash C B Gopinath
- Institute of Nano Electronic Engineering, Universiti Malaysia Perlis (UniMAP), 01000, Kangar, Perlis, Malaysia
- Faculty of Chemical Engineering & Technology, Universiti Malaysia Perlis (UniMAP), 02600, Arau, Perlis, Malaysia
- Micro System Technology, Centre of Excellence (CoE), Universiti Malaysia Perlis (UniMAP), Pauh Campus, 02600, Arau, Perlis, Malaysia
| | - Pandian Bothi Raja
- School of Chemical Sciences, Universiti Sains Malaysia, 11800, Gelugor, Penang, Malaysia.
| |
Collapse
|
16
|
Park G, Park H, Park SC, Jang M, Yoon J, Ahn JH, Lee T. Recent Developments in DNA-Nanotechnology-Powered Biosensors for Zika/Dengue Virus Molecular Diagnostics. NANOMATERIALS (BASEL, SWITZERLAND) 2023; 13:361. [PMID: 36678114 PMCID: PMC9864780 DOI: 10.3390/nano13020361] [Citation(s) in RCA: 11] [Impact Index Per Article: 5.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 12/23/2022] [Revised: 01/09/2023] [Accepted: 01/11/2023] [Indexed: 06/17/2023]
Abstract
Zika virus (ZIKV) and dengue virus (DENV) are highly contagious and lethal mosquito-borne viruses. Global warming is steadily increasing the probability of ZIKV and DENV infection, and accurate diagnosis is required to control viral infections worldwide. Recently, research on biosensors for the accurate diagnosis of ZIKV and DENV has been actively conducted. Moreover, biosensor research using DNA nanotechnology is also increasing, and has many advantages compared to the existing diagnostic methods, such as polymerase chain reaction (PCR) and enzyme-linked immunosorbent assay (ELISA). As a bioreceptor, DNA can easily introduce a functional group at the 5' or 3' end, and can also be used as a folded structure, such as a DNA aptamer and DNAzyme. Instead of using ZIKV and DENV antibodies, a bioreceptor that specifically binds to viral proteins or nucleic acids has been fabricated and introduced using DNA nanotechnology. Technologies for detecting ZIKV and DENV can be broadly divided into electrochemical, electrical, and optical. In this review, advances in DNA-nanotechnology-based ZIKV and DENV detection biosensors are discussed.
Collapse
Affiliation(s)
- Goeun Park
- Department of Chemical Engineering, Kwangwoon University, Seoul 01897, Republic of Korea
| | - Hanbin Park
- Department of Chemical Engineering, Kwangwoon University, Seoul 01897, Republic of Korea
| | - Sang-Chan Park
- Department of Electronics Engineering, Chungnam National University, 99 Daehak-ro, Yuseong-gu, Daejeon 34134, Republic of Korea
| | - Moonbong Jang
- Department of Chemical Engineering, Kwangwoon University, Seoul 01897, Republic of Korea
| | - Jinho Yoon
- Department of Biomedical-Chemical Engineering, The Catholic University of Korea, 43 Jibong-ro, Wonmi-gu, Bucheon-si 14662, Gyeonggi-do, Republic of Korea
| | - Jae-Hyuk Ahn
- Department of Electronics Engineering, Chungnam National University, 99 Daehak-ro, Yuseong-gu, Daejeon 34134, Republic of Korea
| | - Taek Lee
- Department of Chemical Engineering, Kwangwoon University, Seoul 01897, Republic of Korea
- TL Bioindustry, 20 Kwangwoon-ro, Nowon-gu, Seoul 01897, Republic of Korea
| |
Collapse
|
17
|
Rodrigues Oliveira SM, Rebocho A, Ahmadpour E, Nissapatorn V, de Lourdes Pereira M. Type 1 Diabetes Mellitus: A Review on Advances and Challenges in Creating Insulin Producing Devices. MICROMACHINES 2023; 14:151. [PMID: 36677212 PMCID: PMC9867263 DOI: 10.3390/mi14010151] [Citation(s) in RCA: 24] [Impact Index Per Article: 12.0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 08/02/2022] [Revised: 12/25/2022] [Accepted: 12/30/2022] [Indexed: 06/17/2023]
Abstract
Type 1 diabetes mellitus (T1DM) is the most common autoimmune chronic disease in young patients. It is caused by the destruction of pancreatic endocrine β-cells that produce insulin in specific areas of the pancreas, known as islets of Langerhans. As a result, the body becomes insulin deficient and hyperglycemic. Complications associated with diabetes are life-threatening and the current standard of care for T1DM consists still of insulin injections. Lifesaving, exogenous insulin replacement is a chronic and costly burden of care for diabetic patients. Alternative therapeutic options have been the focus in these fields. Advances in molecular biology technologies and in microfabrication have enabled promising new therapeutic options. For example, islet transplantation has emerged as an effective treatment to restore the normal regulation of blood glucose in patients with T1DM. However, this technique has been hampered by obstacles, such as limited islet availability, extensive islet apoptosis, and poor islet vascular engraftment. Many of these unsolved issues need to be addressed before a potential cure for T1DM can be a possibility. New technologies like organ-on-a-chip platforms (OoC), multiplexed assessment tools and emergent stem cell approaches promise to enhance therapeutic outcomes. This review will introduce the disorder of type 1 diabetes mellitus, an overview of advances and challenges in the areas of microfluidic devices, monitoring tools, and prominent use of stem cells, and how they can be linked together to create a viable model for the T1DM treatment. Microfluidic devices like OoC platforms can establish a crucial platform for pathophysiological and pharmacological studies as they recreate the pancreatic environment. Stem cell use opens the possibility to hypothetically generate a limitless number of functional pancreatic cells. Additionally, the integration of stem cells into OoC models may allow personalized or patient-specific therapies.
Collapse
Affiliation(s)
- Sonia M. Rodrigues Oliveira
- HMRI-Hunter Medical Research Institute, New Lambton, NSW 2305, Australia
- CICECO-Aveiro Institute of Materials, University of Aveiro, 3810-193 Aveiro, Portugal
| | - António Rebocho
- Department of Biology, University of Aveiro, 3810-193 Aveiro, Portugal
| | - Ehsan Ahmadpour
- Drug Applied Research Center, Department of Parasitology and Mycology, Tabriz University of Medical Sciences, Tabriz 5166/15731, Iran
- Department of Parasitology and Mycology, Faculty of Medicine, Tabriz University of Medical Sciences, Tabriz 5166/15731, Iran
| | - Veeranoot Nissapatorn
- Department of Medical Technology, School of Allied Health Sciences, Walailak University, Nakhon Si Thammarat 80160, Thailand
- School of Allied Health Sciences, Southeast Asia Water Team (SEAWater Team), World Union for Herbal Drug Discovery (WUHeDD), Research Excellence Center for Innovation and Health Products, Walailak University, Nakhon Si Thammarat 80160, Thailand
| | - Maria de Lourdes Pereira
- CICECO-Aveiro Institute of Materials, University of Aveiro, 3810-193 Aveiro, Portugal
- Department of Medical Sciences, University of Aveiro, 3810-193 Aveiro, Portugal
| |
Collapse
|
18
|
Siavash Moakhar R, del Real Mata C, Jalali M, Shafique H, Sanati A, de Vries J, Strauss J, AbdElFatah T, Ghasemi F, McLean M, I. Hosseini I, Lu Y, Yedire SG, Mahshid SS, Tabatabaiefar MA, Liang C, Mahshid S. A Versatile Biomimic Nanotemplating Fluidic Assay for Multiplex Quantitative Monitoring of Viral Respiratory Infections and Immune Responses in Saliva and Blood. ADVANCED SCIENCE (WEINHEIM, BADEN-WURTTEMBERG, GERMANY) 2022; 9:e2204246. [PMID: 36253095 PMCID: PMC9685479 DOI: 10.1002/advs.202204246] [Citation(s) in RCA: 18] [Impact Index Per Article: 6.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 07/25/2022] [Indexed: 05/17/2023]
Abstract
The last pandemic exposed critical gaps in monitoring and mitigating the spread of viral respiratory infections at the point-of-need. A cost-effective multiplexed fluidic device (NFluidEX), as a home-test kit analogous to a glucometer, that uses saliva and blood for parallel quantitative detection of viral infection and body's immune response in an automated manner within 11 min is proposed. The technology integrates a versatile biomimetic receptor based on molecularly imprinted polymers in a core-shell structure with nano gold electrodes, a multiplexed fluidic-impedimetric readout, built-in saliva collection/preparation, and smartphone-enabled data acquisition and interpretation. NFluidEX is validated with Influenza A H1N1 and SARS-CoV-2 (original strain and variants of concern), and achieves low detection limit in saliva and blood for the viral proteins and the anti-receptor binding domain (RBD) Immunoglobulin G (IgG) and Immunoglobulin M (IgM), respectively. It is demonstrated that nanoprotrusions of gold electrodes are essential for the fine templating of antibodies and spike proteins during molecular imprinting, and differentiation of IgG and IgM in whole blood. In the clinical setting, NFluidEX achieves 100% sensitivity and 100% specificity by testing 44 COVID-positive and 25 COVID-negative saliva and blood samples on par with the real-time quantitative polymerase chain reaction (p < 0.001, 95% confidence) and the enzyme-linked immunosorbent assay.
Collapse
Affiliation(s)
| | | | - Mahsa Jalali
- Department of BioengineeringMcGill UniversityMontrealQuebecH3A 0E9Canada
| | - Houda Shafique
- Department of BioengineeringMcGill UniversityMontrealQuebecH3A 0E9Canada
| | - Alireza Sanati
- Biosensor Research CenterIsfahan University of Medical SciencesIsfahan81746‐73461Iran
| | - Justin de Vries
- Department of BioengineeringMcGill UniversityMontrealQuebecH3A 0E9Canada
| | - Julia Strauss
- Department of BioengineeringMcGill UniversityMontrealQuebecH3A 0E9Canada
| | - Tamer AbdElFatah
- Department of BioengineeringMcGill UniversityMontrealQuebecH3A 0E9Canada
| | - Fahimeh Ghasemi
- Biosensor Research CenterIsfahan University of Medical SciencesIsfahan81746‐73461Iran
| | - Myles McLean
- Department of MedicineMcGill UniversityMontrealQuebecH4A 3J1Canada
- Lady Davis Institute for Medical Research and McGill AIDS CentreJewish General HospitalMontrealQCH3T 1E2Canada
| | - Imman I. Hosseini
- Department of BioengineeringMcGill UniversityMontrealQuebecH3A 0E9Canada
| | - Yao Lu
- Department of BioengineeringMcGill UniversityMontrealQuebecH3A 0E9Canada
| | | | - Sahar Sadat Mahshid
- Biological SciencesSunnybrook Research InstituteSunnybrook Health Sciences CentreTorontoONM4N 3M5Canada
| | - Mohammad Amin Tabatabaiefar
- Department of Genetics and Molecular BiologySchool of MedicineIsfahan University of Medical SciencesIsfahan81746‐73461Iran
| | - Chen Liang
- Department of MedicineMcGill UniversityMontrealQuebecH4A 3J1Canada
- Lady Davis Institute for Medical Research and McGill AIDS CentreJewish General HospitalMontrealQCH3T 1E2Canada
| | - Sara Mahshid
- Department of BioengineeringMcGill UniversityMontrealQuebecH3A 0E9Canada
| |
Collapse
|
19
|
Ribeiro JF, Melo JR, Santos CDL, Chaves CR, Cabral Filho PE, Pereira G, Santos BS, Pereira GA, Rosa DS, Ribeiro RT, Fontes A. Sensitive Zika Biomarker Detection Assisted by Quantum Dot-Modified Electrochemical Immunosensing Platform. Colloids Surf B Biointerfaces 2022; 221:112984. [DOI: 10.1016/j.colsurfb.2022.112984] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/25/2022] [Revised: 09/04/2022] [Accepted: 10/27/2022] [Indexed: 11/06/2022]
|
20
|
Roberts A, Gandhi S. A brief review on novel biomarkers identified and advanced biosensing technologies developed for rapid diagnosis of Japanese Encephalitis Virus. PROCEEDINGS OF THE INDIAN NATIONAL SCIENCE ACADEMY 2022. [PMCID: PMC9483901 DOI: 10.1007/s43538-022-00113-1] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/18/2022]
Abstract
Advanced biosensor technology research is imperative for the management of infectious disease outbreaks such as Japanese Encephalitis (JE), a zoonotic disease caused by the flavivirus JE virus (JEV) which is transmitted to humans (dead-end hosts) from the amplification host, pigs, via mosquitoes. To avoid future pandemic scenarios, proactive research rather than responsive research in the field of diagnostics is a requirement for development of rapid, sensitive and specific screening detection methods. In this mini-review, we have critically compared and evaluated the different types of biomarkers (antigen, antibody, nucleic acid) identified for JEV diagnostics and their specific roles in the manifestation of the infection which may be potentially used for therapeutics and drug development as no treatment is available for JE. Furthermore, different biosensors developed for the detection of JEV biomarkers have been discussed in detail to give an overview of the working principles (electrochemical, optical, etc.), fabrication components (signal amplifier, bioreceptor, etc.), detection limits and response times. This review provides a compact compiled base on available JEV diagnostic research work being currently carried out along with their limitations, future prospective, and major challenges faced. This will enable future development of rapid point-of-care diagnostic screening methods for JEV infection management, which may help reduce number of fatalities.
Collapse
Affiliation(s)
- Akanksha Roberts
- DBT-National Institute of Animal Biotechnology (NIAB), Hyderabad, Telangana 500032 India
- DBT-Regional Centre for Biotechnology (RCB), Faridabad, Haryana 121001 India
| | - Sonu Gandhi
- DBT-National Institute of Animal Biotechnology (NIAB), Hyderabad, Telangana 500032 India
- DBT-Regional Centre for Biotechnology (RCB), Faridabad, Haryana 121001 India
| |
Collapse
|
21
|
Barhoum A, J Forster R. Label-free electrochemical immunosensor for picomolar detection of the cervical cancer biomarker MCM5. Anal Chim Acta 2022; 1225:340226. [PMID: 36038236 DOI: 10.1016/j.aca.2022.340226] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/31/2022] [Revised: 07/28/2022] [Accepted: 07/31/2022] [Indexed: 01/15/2023]
Abstract
An immunosensor for label-free electrochemical detection of MiniChromosome Maintenance Protein 5, MCM5, a protein overexpressed in cervical cancer, based on a gold electrode is reported. The electrode was first modified with a submonolayer (capture layer) of 11-mercaptoundecanoic acid (11-MUA) and then activated with N-(3-dimethylaminopropyl)-N-ethylcarbodiimide hydrochloride (EDC) and N-hydroxysuccinimide (NHS) to immobilize the capture antibody. The change in electrode surface properties (wettability) during the formation of the 11-MUA layers was determined using the static water contact angle (WCA). The binding of MCM5 antigens to the capture antibody was monitored by cyclic voltammetry (CV) and electrochemical impedance spectroscopy (EIS) using 5 mM [Fe(CN)6]3-/4- in 0.1 M LiClO4(aq) as an electroactive probe. AC Impedance was used to measure charge transfer resistance (Rct), which reflects impeded electron transfer when the antigen is bound to the antibody functionalized surface. After exposing the antibody-functionalized surface to MCM5 antigens, Rct increases linearly with the logarithmic value of MCM5 antigen concentration, with a linear dynamic range of 10-6 to 10-11 g/mL, a correlation coefficient of 0.99, and a detection limit of 2.9 pM (10-11 g/mL). This excellent sensitivity was achieved with simple preparation steps and minimal reagent consumption, without the need for complicated procedures such as enzymatic amplification, fluorescent labeling, or nanoparticle modification.
Collapse
Affiliation(s)
- Ahmed Barhoum
- National Centre for Sensor Research, School of Chemical Sciences, Dublin City University, Dublin, D09 V209, Ireland.
| | - Robert J Forster
- National Centre for Sensor Research, School of Chemical Sciences, Dublin City University, Dublin, D09 V209, Ireland
| |
Collapse
|
22
|
Mohsin F, Suleman S, Anzar N, Narang J, Wadhwa S. A review on Japanese Encephalitis virus emergence, pathogenesis and detection: From conventional diagnostics to emerging rapid detection techniques. Int J Biol Macromol 2022; 217:435-448. [PMID: 35817236 DOI: 10.1016/j.ijbiomac.2022.07.027] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/02/2021] [Revised: 12/29/2021] [Accepted: 07/04/2022] [Indexed: 11/18/2022]
Abstract
The virus known as Japanese Encephalitis (JEV) is among the common viral persisting Encephalitis caused by Flavivirus around the Globe, especially in Southeast Asian nations. JEV may be a leading reason for neurological illness in humans, with an estimated 70,000 human cases and 10,000 fatalities per annum. The conventional methods like PRNT (Plaque Reduction Neutralization Test), ELISA (Enzyme-linked immunosorbent assay) RT-PCR (reverse transcription-polymerase chain reaction), and virus isolation are few commercial tests being availed these days, but they have a variety of drawbacks, including being extremely expensive, time-consuming, and requiring expertise. Therefore, researches are being made in the development of improved inexpensive, shorter, sensitive, and time-saving strategies to diagnose the Japanese Encephalitis Virus. A number of these researches encompass the employment of immunosensors, electrochemical sensors and along with the applications of nanotechnology to create highly sensitive detecting device. This review article is based on contemporary breakthroughs in diagnosing Japanese Encephalitis Virus, which are crucial in severing the connection between the propagation of zoonotic disease into the current race, where humans function as dead-end hosts.
Collapse
Affiliation(s)
- Fatima Mohsin
- Department of Biotechnology, School of Chemical and Life Science, Jamia Hamdard, New Delhi 110062, India
| | - Shariq Suleman
- Department of Biotechnology, School of Chemical and Life Science, Jamia Hamdard, New Delhi 110062, India
| | - Nigar Anzar
- Department of Biotechnology, School of Chemical and Life Science, Jamia Hamdard, New Delhi 110062, India
| | - Jagriti Narang
- Department of Biotechnology, School of Chemical and Life Science, Jamia Hamdard, New Delhi 110062, India.
| | - Shikha Wadhwa
- Department of Chemistry, School of Applied Sciences, University of Petroleum & Energy Studies, Bidholi Campus, Dehradun 248007, India
| |
Collapse
|
23
|
Zambry NS, Obande GA, Khalid MF, Bustami Y, Hamzah HH, Awang MS, Aziah I, Manaf AA. Utilizing Electrochemical-Based Sensing Approaches for the Detection of SARS-CoV-2 in Clinical Samples: A Review. BIOSENSORS 2022; 12:473. [PMID: 35884276 PMCID: PMC9312918 DOI: 10.3390/bios12070473] [Citation(s) in RCA: 6] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 05/22/2022] [Revised: 06/20/2022] [Accepted: 06/21/2022] [Indexed: 05/16/2023]
Abstract
The development of precise and efficient diagnostic tools enables early treatment and proper isolation of infected individuals, hence limiting the spread of coronavirus disease 2019 (COVID-19). The standard diagnostic tests used by healthcare workers to diagnose severe acute respiratory syndrome coronavirus-2 (SARS-CoV-2) infection have some limitations, including longer detection time, the need for qualified individuals, and the use of sophisticated bench-top equipment, which limit their use for rapid SARS-CoV-2 assessment. Advances in sensor technology have renewed the interest in electrochemical biosensors miniaturization, which provide improved diagnostic qualities such as rapid response, simplicity of operation, portability, and readiness for on-site screening of infection. This review gives a condensed overview of the current electrochemical sensing platform strategies for SARS-CoV-2 detection in clinical samples. The fundamentals of fabricating electrochemical biosensors, such as the chosen electrode materials, electrochemical transducing techniques, and sensitive biorecognition molecules, are thoroughly discussed in this paper. Furthermore, we summarised electrochemical biosensors detection strategies and their analytical performance on diverse clinical samples, including saliva, blood, and nasopharyngeal swab. Finally, we address the employment of miniaturized electrochemical biosensors integrated with microfluidic technology in viral electrochemical biosensors, emphasizing its potential for on-site diagnostics applications.
Collapse
Affiliation(s)
- Nor Syafirah Zambry
- Institute for Research in Molecular Medicine (INFORMM), Health Campus, Universiti Sains Malaysia, Kubang Kerian 16150, Kelantan, Malaysia; (N.S.Z.); (M.F.K.)
| | - Godwin Attah Obande
- Department of Medical Microbiology and Parasitology, Universiti Sains Malaysia, Kubang Kerian 16150, Kelantan, Malaysia;
- Department of Microbiology, Faculty of Science, Federal University of Lafia, Lafia PMB 146, Nasarawa State, Nigeria
| | - Muhammad Fazli Khalid
- Institute for Research in Molecular Medicine (INFORMM), Health Campus, Universiti Sains Malaysia, Kubang Kerian 16150, Kelantan, Malaysia; (N.S.Z.); (M.F.K.)
| | - Yazmin Bustami
- School of Biological Sciences, Universiti Sains Malaysia, Gelugor 11800, Pulau Pinang, Malaysia;
| | - Hairul Hisham Hamzah
- School of Chemical Sciences, Universiti Sains Malaysia, Gelugor 11800, Pulau Pinang, Malaysia;
| | - Mohd Syafiq Awang
- Collaborative Microelectronic Design Excellence Centre (CEDEC), Sains@USM, Universiti Sains Malaysia, Bayan Lepas 11900, Pulau Pinang, Malaysia;
| | - Ismail Aziah
- Institute for Research in Molecular Medicine (INFORMM), Health Campus, Universiti Sains Malaysia, Kubang Kerian 16150, Kelantan, Malaysia; (N.S.Z.); (M.F.K.)
| | - Asrulnizam Abd Manaf
- Collaborative Microelectronic Design Excellence Centre (CEDEC), Sains@USM, Universiti Sains Malaysia, Bayan Lepas 11900, Pulau Pinang, Malaysia;
| |
Collapse
|
24
|
Metabolomic Analysis of Key Regulatory Metabolites in the Urine of Flavivirus-Infected Mice. J Trop Med 2022; 2022:4663735. [PMID: 35693845 PMCID: PMC9177292 DOI: 10.1155/2022/4663735] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/23/2022] [Accepted: 05/12/2022] [Indexed: 11/30/2022] Open
Abstract
Objective Dengue virus (DENV), Japanese encephalitis virus (JEV), and Zika virus (ZIKV) are several important flaviviruses, and infections caused by these flaviviruses remain worldwide health problems. Different flaviviruses exhibit different biological characteristics and pathogenicity. Metabolomics is an emerging research perspective to uncover and observe the pathogenesis of certain infections. Methods To improve the understanding of the specific metabolic changes that occur during infection with different flaviviruses, considering the principle of noninvasive sampling, this article describes our comprehensive analysis of metabolites in urine samples from the three kinds of flavivirus-infected mice using a liquid chromatography tandem mass spectrometry method to better understand their infection mechanisms. Results The urine of DENV-, JEV-, and ZIKV-infected mice had 68, 64, and 47 different differential metabolites, respectively, compared with the urine of control mice. Among the metabolic pathways designed by these metabolites, ABC transporters, arginine and proline metabolism, and regulation of lipolysis play an important role. Furthermore, we predicted and fitted potential relationships between metabolites and pathways. Conclusions These virus-specific altered metabolites may be associated with their unique biological properties and pathogenicity. The metabolomic analysis of urine is very important for the analysis of flavivirus infection.
Collapse
|
25
|
Svitková V, Konderíková K, Nemčeková K. Photoelectrochemical aptasensors for detection of viruses. MONATSHEFTE FUR CHEMIE 2022; 153:963-970. [PMID: 35345838 PMCID: PMC8943106 DOI: 10.1007/s00706-022-02913-z] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 01/03/2022] [Accepted: 03/15/2022] [Indexed: 10/31/2022]
Abstract
Photoelectrochemistry (PEC) is a dynamic discipline studying the effect of light on photoelectrode or photosensitive material, and the conversion from solar energy into electrical power. The basic PEC process refers to the oxidation or reduction reactions between electrochemical active species in solution and photoactive materials that occurred at the electrode/electrolyte interface during illumination. In recent years, the PEC biosensing approaches have also been developed by the combination of the PEC technique with bioanalysis, where the interaction between biological recognition element and analyte influences a photocurrent signal. This involves the charge and energy transfer of PEC reaction between electron donor/acceptor and photoactive material upon light irradiation. Coupling the advantages of PEC bioanalysis and aptamers has provided new concepts for highly selective and sensitive biosensors development, applicable in human health monitoring and environmental protection. In a typical assay, a photoactive material converts the affinity binding properties of aptamers into a detectable electrical signal, presenting an innovative method for probing numerous aptamer-analyte interactions. Using different aptamer probes aiming for specific purposes, more sensing strategies with rational design and exquisite signaling mechanisms have been proposed. This review concentrated on the current topic of PEC aptasensors that are used for the detection of viruses. The prospects in this area are also discussed. Graphical abstract
Collapse
Affiliation(s)
- Veronika Svitková
- Institute of Analytical Chemistry, Faculty of Chemical and Food Technology, Slovak University of Technology in Bratislava, Radlinského 9, 81237 Bratislava, Slovakia
| | - Kristína Konderíková
- Institute of Analytical Chemistry, Faculty of Chemical and Food Technology, Slovak University of Technology in Bratislava, Radlinského 9, 81237 Bratislava, Slovakia
| | - Katarína Nemčeková
- Institute of Analytical Chemistry, Faculty of Chemical and Food Technology, Slovak University of Technology in Bratislava, Radlinského 9, 81237 Bratislava, Slovakia
| |
Collapse
|
26
|
Siqueira Silva M, Moreira Tavares AP, Leomil Coelho LF, Morganti Ferreira Dias LE, Chura-Chambi RM, Guimarães da Fonseca F, Ferreira Sales MG, Costa Figueiredo E. Rational selection of hidden epitopes for a molecularly imprinted electrochemical sensor in the recognition of heat-denatured dengue NS1 protein. Biosens Bioelectron 2021; 191:113419. [PMID: 34144470 DOI: 10.1016/j.bios.2021.113419] [Citation(s) in RCA: 11] [Impact Index Per Article: 2.8] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/25/2021] [Revised: 05/30/2021] [Accepted: 06/05/2021] [Indexed: 10/21/2022]
Abstract
Rational selection of predicted peptides to be employed as templates in molecular imprinting was carried out for the heat-denatured non-structural protein 1 (NS1) of dengue virus (DENV). Conservation analysis among 301 sequences of Brazilian isolates of DENV and zika virus (ZIKV) NS1 was carried out by UniProtKB, and peptide selection was based on in silico data of the conservational, structural and immunogenic properties of the sequences. The selected peptide (from dengue 1 NS1) was synthesized and employed as a template in the electropolymerization of polyaminophenol-imprinted films on the surface of carbon screen-printed electrodes. Heat denaturation of the protein was carried out prior to analysis, in order to expose its internal hidden epitopes. After removal of the template, the molecularly imprinted cavities were able to rebind to the whole denatured protein as determined by electrochemical impedance spectroscopy. This label-free sensor was efficient to distinguish the NS1 of DENV from the NS1 of ZIKV. Additionally, the sensor was also selective for dengue NS1, in comparison with human serum immunoglobulin G and human serum albumin. Additionally, the device was able to detect the DENV NS1 at concentrations from 50 to 200 μg L-1 (RSD below 5.04%, r = 0.9678) in diluted human serum samples. The calculated LOD and LOQ were, respectively, 29.3 and 88.7 μg L-1 and each sensor could be used for six sequential cycles with the same performance.
Collapse
Affiliation(s)
- Matheus Siqueira Silva
- Laboratory of Toxicant and Drug Analyses, Federal University of Alfenas, 37130-001, Alfenas, MG, Brazil
| | - Ana Patricia Moreira Tavares
- BioMark@ISEP, School of Engineering of the Polytechnic School of Porto, 4200-072, Paranhos, Portugal; BioMark@UC, Department of Chemical Engineering, Faculty of Sciences and Technology of the University of Coimbra, 3030-790, Coimbra, Portugal
| | - Luiz Felipe Leomil Coelho
- Laboratory of Vaccines, Department of Microbiology and Immunology, Institute of Biomedical Sciences, Federal University of Alfenas, 37130-001, Alfenas, MG, Brazil
| | | | - Rosa Maria Chura-Chambi
- Center of Biotechnology, Institute of Energetic and Nuclear Research, IPEN-CNEN/SP, 05508-000, São Paulo, SP, Brazil
| | | | - Maria Goreti Ferreira Sales
- BioMark@ISEP, School of Engineering of the Polytechnic School of Porto, 4200-072, Paranhos, Portugal; BioMark@UC, Department of Chemical Engineering, Faculty of Sciences and Technology of the University of Coimbra, 3030-790, Coimbra, Portugal.
| | - Eduardo Costa Figueiredo
- Laboratory of Toxicant and Drug Analyses, Federal University of Alfenas, 37130-001, Alfenas, MG, Brazil.
| |
Collapse
|
27
|
Mascini M, Dikici E, Perez-Erviti JA, Deo SK, Compagnone D, Daunert S. A new class of sensing elements for sensors: Clamp peptides for Zika virus. Biosens Bioelectron 2021; 191:113471. [PMID: 34246123 DOI: 10.1016/j.bios.2021.113471] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/20/2021] [Revised: 05/25/2021] [Accepted: 06/28/2021] [Indexed: 12/20/2022]
Abstract
The design of a new class of selective and high affinity antibody mimetics termed clamp peptide (CP) that incorporate three short peptides structurally and mechanically mimicking a clamp is proposed as sensing elements for a reliable detection sensor platform. The CPs consist of two short peptides functioning as arms that recognize two different epitopes in the target protein and are connected by a third short peptide that acts as a hinge between the peptide arms. For the construction of CPs, we employed a rational design combined with computational methods. To illustrate our approach, we designed a CP that binds selectively to the envelope protein of the Zika virus (ZIKV). The virtual docking cycles were run maximizing the discrimination between ZIKV and Dengue virus (DENV) envelope proteins. DENV was chosen among the flavivirus family because it has high structural similarity with ZIKV. When employed in a colorimetric binding assay or in label-free electrochemical impedance sensor format, the CP was selective for ZIKV vs DENV particles showing detection limit under 104 copies/mL, comparable to anti-ZIKV antibodies. Apparent dissociation binding constants (Kd) confirmed a better performance of CPs than mono-arm peptides (Kd of best CP = 162 nM ± 23 nM; Kd of best mono-arm peptide = 11.15 ± 2.76 μM). The performance of the assays based on CPs was also verified in serum and urine (diluted 1:10 and 1:1 respectively). The detection limits of CPs decreased about one order of magnitude for ZIKV detection in serum or urine, with a distinct analytical signal starting from 105 copies/mL of ZIKV.
Collapse
Affiliation(s)
- Marcello Mascini
- Faculty of Bioscience and Technology for Food, Agriculture and Environment, University of Teramo, 64100, Teramo, Italy; Department of Analytical Chemistry, Faculty of Chemistry, University Complutense of Madrid, Ciudad Universitaria S/n, 28040, Madrid, Spain.
| | - Emre Dikici
- Department of Biochemistry and Molecular Biology, Miller School of Medicine, University of Miami, Miami, FL, 33136, United States; Dr. JT Macdonald Foundation Biomedical Nanotechnology Institute, University of Miami, Miami, FL, 33136, United States
| | - Julio A Perez-Erviti
- Center for Protein Studies, Faculty of Biology, University of Havana, La Havana, 10400, Cuba
| | - Sapna K Deo
- Department of Biochemistry and Molecular Biology, Miller School of Medicine, University of Miami, Miami, FL, 33136, United States; Dr. JT Macdonald Foundation Biomedical Nanotechnology Institute, University of Miami, Miami, FL, 33136, United States
| | - Dario Compagnone
- Faculty of Bioscience and Technology for Food, Agriculture and Environment, University of Teramo, 64100, Teramo, Italy
| | - Sylvia Daunert
- Department of Biochemistry and Molecular Biology, Miller School of Medicine, University of Miami, Miami, FL, 33136, United States; Dr. JT Macdonald Foundation Biomedical Nanotechnology Institute, University of Miami, Miami, FL, 33136, United States; University of Miami Clinical and Translational Science Institute, University of Miami, Miami, FL, 33136, United States.
| |
Collapse
|
28
|
Phetsang S, Khwannimit D, Rattanakit P, Chanlek N, Kidkhunthod P, Mungkornasawakul P, Jakmunee J, Ounnunkad K. A Redox Cu(II)-Graphene Oxide Modified Screen Printed Carbon Electrode as a Cost-Effective and Versatile Sensing Platform for Electrochemical Label-Free Immunosensor and Non-enzymatic Glucose Sensor. Front Chem 2021; 9:671173. [PMID: 34095085 PMCID: PMC8172615 DOI: 10.3389/fchem.2021.671173] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/23/2021] [Accepted: 04/14/2021] [Indexed: 11/24/2022] Open
Abstract
A novel copper (II) ions [Cu(II)]-graphene oxide (GO) nanocomplex-modified screen-printed carbon electrode (SPCE) is successfully developed as a versatile electrochemical platform for construction of sensors without an additionally external redox probe. A simple strategy to prepare the redox GO-modified SPCE is described. Such redox GO based on adsorbed Cu(II) is prepared by incubation of GO-modified SPCE in the Cu(II) solution. This work demonstrates the fabrications of two kinds of electrochemical sensors, i.e., a new label-free electrochemical immunosensor and non-enzymatic sensor for detections of immunoglobulin G (IgG) and glucose, respectively. Our immunosensor based on square-wave voltammetry (SWV) of the redox GO-modified electrode shows the linearity in a dynamic range of 1.0-500 pg.mL-1 with a limit of detection (LOD) of 0.20 pg.mL-1 for the detection of IgG while non-enzymatic sensor reveals two dynamic ranges of 0.10-1.00 mM (sensitivity = 36.31 μA.mM-1.cm-2) and 1.00-12.50 mM (sensitivity = 3.85 μA.mM-1.cm-2) with a LOD value of 0.12 mM. The novel redox Cu(II)-GO composite electrode is a promising candidate for clinical research and diagnosis.
Collapse
Affiliation(s)
- Sopit Phetsang
- Department of Chemistry, Faculty of Science, Chiang Mai University, Chiang Mai, Thailand
- National Institute of Technology, Nagaoka College, Niigata, Japan
| | - Duangruedee Khwannimit
- Department of Chemistry, Faculty of Science, Chiang Mai University, Chiang Mai, Thailand
- Division of Chemistry, School of Science, Walailak University, Nakhon Si Thammarat, Thailand
| | - Parawee Rattanakit
- Division of Chemistry, School of Science, Walailak University, Nakhon Si Thammarat, Thailand
| | - Narong Chanlek
- Synchrotron Light Research Institute (Public Organization), Nakhon Ratchasima, Thailand
| | - Pinit Kidkhunthod
- Synchrotron Light Research Institute (Public Organization), Nakhon Ratchasima, Thailand
| | - Pitchaya Mungkornasawakul
- Department of Chemistry, Faculty of Science, Chiang Mai University, Chiang Mai, Thailand
- Environmental Science Research Center, Faculty of Science, Chiang Mai University, Chiang Mai, Thailand
| | - Jaroon Jakmunee
- Department of Chemistry, Faculty of Science, Chiang Mai University, Chiang Mai, Thailand
- Center of Excellence for Innovation in Chemistry, Faculty of Science, Chiang Mai University, Chiang Mai, Thailand
- Research Center on Chemistry for Development of Health Promoting Products from Northern Resources, Chiang Mai University, Chiang Mai, Thailand
| | - Kontad Ounnunkad
- Department of Chemistry, Faculty of Science, Chiang Mai University, Chiang Mai, Thailand
- Center of Excellence for Innovation in Chemistry, Faculty of Science, Chiang Mai University, Chiang Mai, Thailand
- Research Center on Chemistry for Development of Health Promoting Products from Northern Resources, Chiang Mai University, Chiang Mai, Thailand
- Center of Excellence in Materials Science and Technology, Chiang Mai University, Chiang Mai, Thailand
| |
Collapse
|
29
|
Goud KY, Reddy KK, Khorshed A, Kumar VS, Mishra RK, Oraby M, Ibrahim AH, Kim H, Gobi KV. Electrochemical diagnostics of infectious viral diseases: Trends and challenges. Biosens Bioelectron 2021; 180:113112. [PMID: 33706158 PMCID: PMC7921732 DOI: 10.1016/j.bios.2021.113112] [Citation(s) in RCA: 52] [Impact Index Per Article: 13.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/05/2021] [Revised: 02/06/2021] [Accepted: 02/22/2021] [Indexed: 02/07/2023]
Abstract
Infectious diseases caused by viruses can elevate up to undesired pandemic conditions affecting the global population and normal life function. These in turn impact the established world economy, create jobless situations, physical, mental, emotional stress, and challenge the human survival. Therefore, timely detection, treatment, isolation and prevention of spreading the pandemic infectious diseases not beyond the originated town is critical to avoid global impairment of life (e.g., Corona virus disease - 2019, COVID-19). The objective of this review article is to emphasize the recent advancements in the electrochemical diagnostics of twelve life-threatening viruses namely - COVID-19, Middle east respiratory syndrome (MERS), Severe acute respiratory syndrome (SARS), Influenza, Hepatitis, Human immunodeficiency virus (HIV), Human papilloma virus (HPV), Zika virus, Herpes simplex virus, Chikungunya, Dengue, and Rotavirus. This review describes the design, principle, underlying rationale, receptor, and mechanistic aspects of sensor systems reported for such viruses. Electrochemical sensor systems which comprised either antibody or aptamers or direct/mediated electron transfer in the recognition matrix were explicitly segregated into separate sub-sections for critical comparison. This review emphasizes the current challenges involved in translating laboratory research to real-world device applications, future prospects and commercialization aspects of electrochemical diagnostic devices for virus detection. The background and overall progress provided in this review are expected to be insightful to the researchers in sensor field and facilitate the design and fabrication of electrochemical sensors for life-threatening viruses with broader applicability to any desired pathogens.
Collapse
Affiliation(s)
- K Yugender Goud
- Department of NanoEngineering, University of California San Diego, La Jolla, CA, 92093, USA.
| | - K Koteshwara Reddy
- Smart Living Innovation Technology Centre, Department of Energy Science and Technology, Myongji University, Yongin, Gyeonggi-do, 17058, Republic of Korea.
| | - Ahmed Khorshed
- Department of Pharmaceutical Analytical Chemistry, Faculty of Pharmacy, Sohag University, Sohag, 82524, Egypt.
| | - V Sunil Kumar
- Department of Chemistry, National Institute of Technology Warangal, Telangana, 506004, India
| | - Rupesh K Mishra
- Department of NanoEngineering, University of California San Diego, La Jolla, CA, 92093, USA
| | - Mohamed Oraby
- Department of Pharmaceutical Analytical Chemistry, Faculty of Pharmacy, Sohag University, Sohag, 82524, Egypt
| | - Alyaa Hatem Ibrahim
- Department of Pharmaceutical Analytical Chemistry, Faculty of Pharmacy, Sohag University, Sohag, 82524, Egypt
| | - Hern Kim
- Smart Living Innovation Technology Centre, Department of Energy Science and Technology, Myongji University, Yongin, Gyeonggi-do, 17058, Republic of Korea.
| | - K Vengatajalabathy Gobi
- Department of Chemistry, National Institute of Technology Warangal, Telangana, 506004, India.
| |
Collapse
|
30
|
Nemčeková K, Labuda J. Advanced materials-integrated electrochemical sensors as promising medical diagnostics tools: A review. MATERIALS SCIENCE & ENGINEERING. C, MATERIALS FOR BIOLOGICAL APPLICATIONS 2020; 120:111751. [PMID: 33545892 DOI: 10.1016/j.msec.2020.111751] [Citation(s) in RCA: 34] [Impact Index Per Article: 6.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 10/15/2020] [Revised: 11/13/2020] [Accepted: 11/21/2020] [Indexed: 02/08/2023]
Abstract
Electrochemical sensors have increasingly been linked with terms as modern biomedically effective highly selective and sensitive devices, wearable and wireless technology, portable electronics, smart textiles, energy storage, communication and user-friendly operating systems. The work brings the overview of the current advanced materials and their application strategies for improving performance, miniaturization and portability of sensing devices. It provides the extensive information on recently developed (bio)sensing platforms based on voltammetric, amperometric, potentiometric and impedimetric detection modes including portable, non-invasive, wireless, and self-driven miniaturized devices for monitoring human and animal health. Diagnostics of selected free radical precursors, low molecular biomarkers, nucleic acids and protein-based biomarkers, bacteria and viruses of today's interest is demonstrated.
Collapse
Affiliation(s)
- Katarína Nemčeková
- Institute of Analytical Chemistry, Faculty of Chemical and Food Technology, Slovak University of Technology in Bratislava, Bratislava 81237, Slovakia.
| | - Ján Labuda
- Institute of Analytical Chemistry, Faculty of Chemical and Food Technology, Slovak University of Technology in Bratislava, Bratislava 81237, Slovakia.
| |
Collapse
|