1
|
Jones J, Campbell A, Kyei I, Sobansky MR, Hager MV, Hage DS. High-performance chromatographic immunoassay utilizing a biotin-streptavidin platform for activity-based analysis of therapeutic monoclonal antibodies. J Chromatogr B Analyt Technol Biomed Life Sci 2025; 1258:124603. [PMID: 40252558 DOI: 10.1016/j.jchromb.2025.124603] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/18/2025] [Revised: 04/07/2025] [Accepted: 04/13/2025] [Indexed: 04/21/2025]
Abstract
There has been rapid growth in the use of monoclonal antibodies (mAbs) as biopharmaceuticals over the last twenty years. This has led to the need for new analytical methods that can rapidly and specifically measure or characterize mAbs for research, development and quality control, including means for the assessment of a therapeutic mAb's biological activity. High-performance immunoaffinity chromatography (HPIAC) was examined in this report as an approach for such work, in which the interactions between an antibody and its antigen were used for the selective isolation and analysis of one of these components. This report describes the utilization of a biotin-streptavidin platform in HPIAC and with affinity microcolumns that were used together in a chromatographic immunoassay for the analysis of a therapeutic mAb. Various components of this method were characterized and optimized to provide a method that was reusable and that could provide results within 7 min. The final assay could measure down to 0.03 mg/mL mAb (1.5 μg) for a 50 μL sample injection. The assay precision was ±0.7-1.3 % based on peak area measurements and ± 1.0-2.4 % using peak heights. The method was then evaluated for its use with typical samples encountered for a therapeutic mAb during its development and processing. Each microcolumn in this assay could be used for more than 350-400 sample application/elution cycles. The extension of this platform and approach to other applications was also considered.
Collapse
Affiliation(s)
- Jacob Jones
- Department of Chemistry, University of Nebraska-Lincoln, Lincoln, NE, USA
| | - Avery Campbell
- Department of Chemistry, University of Nebraska-Lincoln, Lincoln, NE, USA
| | - Isaac Kyei
- Department of Chemistry, University of Nebraska-Lincoln, Lincoln, NE, USA
| | | | | | - David S Hage
- Department of Chemistry, University of Nebraska-Lincoln, Lincoln, NE, USA.
| |
Collapse
|
2
|
Boško R, Pluháčková H, Martiník J, Benešová K, Svoboda Z, Běláková S, Pernica M. Occurrence of mycotoxins in milk thistle: to be included in legislation or not? Mycotoxin Res 2025; 41:199-206. [PMID: 39656435 DOI: 10.1007/s12550-024-00577-8] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/03/2024] [Revised: 11/20/2024] [Accepted: 11/26/2024] [Indexed: 01/24/2025]
Abstract
The silymarin complex extracted from milk thistle provides significant health benefits, particularly due to its antioxidant and hepatoprotective properties. However, plant substances can be contaminated by a number of fungi types and their secondary metabolites-mycotoxins. This work deals with the determination of aflatoxins and zearalenone and its metabolites in 39 different samples grown in 2020 and 2021. Analysis of mycotoxins was performed by UHPLC-MS/MS after immunoaffinity column AFLAPREP® and EASI-EXTRACT® ZEARALENONE clean-up. The presence of aflatoxins was not confirmed in the monitored samples, but 1/3 of the samples were contaminated with zearalenone in the range of 2.8-378.9 µg/kg. Metabolites of zearalenone such as α-zearalenol, α-zearalanol, and β-zearalanol were not detected in any of the samples. β-Zearalenol was found in two samples (2.6 µg/kg and 29.8 µg/kg).
Collapse
Affiliation(s)
- Rastislav Boško
- Research Institute of Brewing and Malting, Mostecká 7, 614 00, Brno, Czech Republic
| | - Helena Pluháčková
- Faculty of AgriSciences, Department of Crop Science, Breeding and Plant Medicine, Mendel University in Brno, Zemědělská 1, 613 00, Brno, Czech Republic
| | - Jan Martiník
- Research Institute of Brewing and Malting, Mostecká 7, 614 00, Brno, Czech Republic
- Department of Biotechnology, University of Chemistry and Technology Prague, Technická 5, 160 00, Prague 6, Prague, Czech Republic
| | - Karolína Benešová
- Research Institute of Brewing and Malting, Mostecká 7, 614 00, Brno, Czech Republic
| | - Zdeněk Svoboda
- Research Institute of Brewing and Malting, Mostecká 7, 614 00, Brno, Czech Republic
- Institute of Food Science and Biotechnology, Faculty of Chemistry, Brno University of Technology, Purkyňova 464/118, 612 00, Brno, Czech Republic
| | - Sylvie Běláková
- Research Institute of Brewing and Malting, Mostecká 7, 614 00, Brno, Czech Republic
| | - Marek Pernica
- Research Institute of Brewing and Malting, Mostecká 7, 614 00, Brno, Czech Republic.
| |
Collapse
|
3
|
Yi X, Li X, Luo H, Lin G, Zhou J, Xiong Y, Wu Y. Development of an automated immunologic mass spectrometry (iMS) method to overcome matrix effect for quantification: Steroid hormones as the example. Talanta 2025; 282:127041. [PMID: 39427409 DOI: 10.1016/j.talanta.2024.127041] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/21/2024] [Revised: 10/08/2024] [Accepted: 10/10/2024] [Indexed: 10/22/2024]
Abstract
Liquid chromatography-tandem mass spectrometry (LC-MS/MS) shows great promise in clinical application for its high specificity, high sensitivity and wide linear range for the determination of small molecules. However, its application in clinical laboratory is hampered by matrix effect of clinical samples which could greatly affect quantification accuracy and the difficulty to be automated for the traditional sample preparation procedures. Thus, new techniques which could achieve selective enrichment to minimize matrix effect and automatic sample preparation of mass spectrometry are needed. We developed an immunologic mass spectrometry (iMS) method to overcome matrix effect and its clinical application was demonstrated for automatic analysis of testosterone (T), progesterone (P) and estradiol (E2) in human serum simultaneously. Firstly, three monoclonal antibodies were coupled to magnetic beads for selective enrichment of target hormones from serum. The immunomagnetic beads were separated, washed and eluted automatically for LC-MS/MS analysis. Analytical performance of the iMS method was validated and compared with traditional LC-MS/MS and chemiluminescence immunoassay (CLIA). Hormone levels were measured for 160 pregnancy women at different gestational weeks. Results showed that target hormones could be selectively captured with absolute recoveries of 93.9%-110.8 %. Relative responses for high, medium and low concentrations of the hormones between serum and methanol solution were 98.0%-109.7 %, 92.2%-105.3 % and 91.7%-96.0 % for T, P and E2, respectively. Calibration curves prepared in methanol solution, BSA solution and blank serum showed good consistency for the iMS method. The automated iMS method could overcome matrix effect of LC-MS/MS and cross-reaction of CLIA. Matrix effect of the iMS method was negligible as high specificity of target hormone enrichment before LC-MS/MS analysis. Matrix-matched calibration standards were no longer necessary for accurate quantification, which was of great benefit for the clinical application of mass spetrometry.
Collapse
Affiliation(s)
- Xiaoyi Yi
- Institute of Antibody Engineering, School of Laboratory Medicine and Biotechnology, Southern Medical University, Guangzhou, 510515, Guangdong, PR China
| | - Xijiu Li
- Institute of Antibody Engineering, School of Laboratory Medicine and Biotechnology, Southern Medical University, Guangzhou, 510515, Guangdong, PR China
| | - Huanchang Luo
- Institute of Antibody Engineering, School of Laboratory Medicine and Biotechnology, Southern Medical University, Guangzhou, 510515, Guangdong, PR China
| | - Guanfeng Lin
- Institute of Antibody Engineering, School of Laboratory Medicine and Biotechnology, Southern Medical University, Guangzhou, 510515, Guangdong, PR China
| | - Jianwei Zhou
- Institute of Antibody Engineering, School of Laboratory Medicine and Biotechnology, Southern Medical University, Guangzhou, 510515, Guangdong, PR China
| | - Yufeng Xiong
- Department of Laboratory Medicine, Nanfang Hospital, Southern Medical University, Guangzhou, 510515, Guangdong, PR China.
| | - Yingsong Wu
- Institute of Antibody Engineering, School of Laboratory Medicine and Biotechnology, Southern Medical University, Guangzhou, 510515, Guangdong, PR China.
| |
Collapse
|
4
|
Mafe AN, Büsselberg D. Mycotoxins in Food: Cancer Risks and Strategies for Control. Foods 2024; 13:3502. [PMID: 39517285 PMCID: PMC11545588 DOI: 10.3390/foods13213502] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/03/2024] [Revised: 10/27/2024] [Accepted: 10/29/2024] [Indexed: 11/16/2024] Open
Abstract
Mycotoxins are toxic compounds produced by fungi such as Aspergillus, Penicillium, and Fusarium, contaminating various food crops and posing severe risks to food safety and human health. This review discusses mycotoxins' origins, significance, and impact, particularly in relation to cancer risk. Major mycotoxins like aflatoxins, ochratoxins, fumonisins, zearalenone, and patulin are examined, along with their sources and affected foods. The carcinogenic mechanisms of these toxins, including their biochemical and molecular interactions, are explored, as well as epidemiological evidence linking mycotoxin exposure to cancer in high-risk populations. The review also highlights critical methodologies for mycotoxin detection, including HPLC, GC-MS, MS, and ELISA, and the sample preparation techniques critical for accurate analysis. Strategies for controlling mycotoxin contamination, both pre- and post-harvest, are discussed, along with regulations from organizations like the FAO and WHO. Current challenges in detection sensitivity, cost, and control effectiveness are noted. Future research is needed to develop innovative analytical techniques, improve control strategies, and address the influence of climate change on mycotoxin production. Finally, global collaboration and emerging technologies are essential for advancing mycotoxin control and enhancing food safety.
Collapse
Affiliation(s)
- Alice N. Mafe
- Department of Biological Sciences, Faculty of Sciences, Taraba State University, Main Campus, Jalingo 660101, Taraba State, Nigeria;
| | - Dietrich Büsselberg
- Weill Cornell Medicine-Qatar, Education City, Qatar Foundation, Doha Metropolitan Area, P.O. Box 22104, Qatar
| |
Collapse
|
5
|
Lai H, Li G. Recent progress on media for biological sample preparation. J Chromatogr A 2024; 1734:465293. [PMID: 39181092 DOI: 10.1016/j.chroma.2024.465293] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/28/2024] [Revised: 08/19/2024] [Accepted: 08/20/2024] [Indexed: 08/27/2024]
Abstract
The analysis of biological samples is highly valuable for disease diagnosis and treatment, forensic examination, and public safety. However, the serious matrix interference effect generated by biological samples severely affects the analysis of trace analytes. Sample preparation methods are introduced to address the limitation by extracting, separating, enriching, purifying trace target analytes from biological samples. With the raising demand of biological sample analysis, a review focuses on media for biological sample preparation and analysis over the last 5 years is presented. High-performance media in biological sample preparation are first reviewed, including porous organic frameworks, imprinted polymers, hydrogels, ionic liquids, and bioactive media. Then, application of media for different biological sample preparation and analysis is briefly introduced, including liquid samples of body fluids, solid samples (hair, feces, and tissues), and gas samples of exhale breath gas. Finally, conclusions and outlooks on media promoting biological sample preparation are presented.
Collapse
Affiliation(s)
- Huasheng Lai
- Jiangxi Province Key Laboratory of Pharmacology of Traditional Chinese Medicine, School of Pharmacy, Gannan Medical University, Ganzhou, 341000, China; School of chemistry, Sun Yat-Sen University, Guangzhou, 510006, China.
| | - Gongke Li
- School of chemistry, Sun Yat-Sen University, Guangzhou, 510006, China.
| |
Collapse
|
6
|
XIE B, LYU Y, LIU Z. [Recent advances of molecular imprinting technology for the separation and recognition of complex biological sample systems]. Se Pu 2024; 42:508-523. [PMID: 38845512 PMCID: PMC11165394 DOI: 10.3724/sp.j.1123.2024.01011] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/10/2024] [Indexed: 06/12/2024] Open
Abstract
Given continuous improvements in industrial production and living standards, the analysis and detection of complex biological sample systems has become increasingly important. Common complex biological samples include blood, serum, saliva, and urine. At present, the main methods used to separate and recognize target analytes in complex biological systems are electrophoresis, spectroscopy, and chromatography. However, because biological samples consist of complex components, they suffer from the matrix effect, which seriously affects the accuracy, sensitivity, and reliability of the selected separation analysis technique. In addition to the matrix effect, the detection of trace components is challenging because the content of the analyte in the sample is usually very low. Moreover, reasonable strategies for sample enrichment and signal amplification for easy analysis are lacking. In response to the various issues described above, researchers have focused their attention on immuno-affinity technology with the aim of achieving efficient sample separation based on the specific recognition effect between antigens and antibodies. Following a long period of development, this technology is now widely used in fields such as disease diagnosis, bioimaging, food testing, and recombinant protein purification. Common immuno-affinity technologies include solid-phase extraction (SPE) magnetic beads, affinity chromatography columns, and enzyme linked immunosorbent assay (ELISA) kits. Immuno-affinity techniques can successfully reduce or eliminate the matrix effect; however, their applications are limited by a number of disadvantages, such as high costs, tedious fabrication procedures, harsh operating conditions, and ligand leakage. Thus, developing an effective and reliable method that can address the matrix effect remains a challenging endeavor. Similar to the interactions between antigens and antibodies as well as enzymes and substrates, biomimetic molecularly imprinted polymers (MIPs) exhibit high specificity and affinity. Furthermore, compared with many other biomacromolecules such as antigens and aptamers, MIPs demonstrate higher stability, lower cost, and easier fabrication strategies, all of which are advantageous to their application. Therefore, molecular imprinting technology (MIT) is frequently used in SPE, chromatographic separation, and many other fields. With the development of MIT, researchers have engineered different types of imprinting strategies that can specifically extract the target analyte in complex biological samples while simultaneously avoiding the matrix effect. Some traditional separation technologies based on MIP technology have also been studied in depth; the most common of these technologies include stationary phases used for chromatography and adsorbents for SPE. Analytical methods that combine MIT with highly sensitive detection technologies have received wide interest in fields such as disease diagnosis and bioimaging. In this review, we highlight the new MIP strategies developed in recent years, and describe the applications of MIT-based separation analysis methods in fields including chromatographic separation, SPE, diagnosis, bioimaging, and proteomics. The drawbacks of these techniques as well as their future development prospects are also discussed.
Collapse
|
7
|
Ben Miri Y, Benabdallah A, Chentir I, Djenane D, Luvisi A, De Bellis L. Comprehensive Insights into Ochratoxin A: Occurrence, Analysis, and Control Strategies. Foods 2024; 13:1184. [PMID: 38672856 PMCID: PMC11049263 DOI: 10.3390/foods13081184] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/07/2024] [Revised: 04/04/2024] [Accepted: 04/09/2024] [Indexed: 04/28/2024] Open
Abstract
Ochratoxin A (OTA) is a toxic mycotoxin produced by some mold species from genera Penicillium and Aspergillus. OTA has been detected in cereals, cereal-derived products, dried fruits, wine, grape juice, beer, tea, coffee, cocoa, nuts, spices, licorice, processed meat, cheese, and other foods. OTA can induce a wide range of health effects attributable to its toxicological properties, including teratogenicity, immunotoxicity, carcinogenicity, genotoxicity, neurotoxicity, and hepatotoxicity. OTA is not only toxic to humans but also harmful to livestock like cows, goats, and poultry. This is why the European Union and various countries regulate the maximum permitted levels of OTA in foods. This review intends to summarize all the main aspects concerning OTA, starting from the chemical structure and fungi that produce it, its presence in food, its toxicity, and methods of analysis, as well as control strategies, including both fungal development and methods of inactivation of the molecule. Finally, the review provides some ideas for future approaches aimed at reducing the OTA levels in foods.
Collapse
Affiliation(s)
- Yamina Ben Miri
- Department of Biochemistry and Microbiology, Faculty of Sciences, Mohamed Boudiaf University, BP 166, M’sila 28000, Algeria;
| | - Amina Benabdallah
- Laboratory on Biodiversity and Ecosystem Pollution, Faculty of Life and Nature Sciences, University Chadli Bendjedid, El-Tarf 36000, Algeria;
| | - Imene Chentir
- Laboratory of Food, Processing, Control and Agri-Resources Valorization, Higher School of Food Science and Agri-Food Industry, Algiers 16200, Algeria;
| | - Djamel Djenane
- Food Quality and Safety Research Laboratory, Department of Food Sciences, Mouloud Mammeri University, BP 17, Tizi-Ouzou 15000, Algeria;
| | - Andrea Luvisi
- Dipartimento di Scienze e Tecnologie Biologiche ed Ambientali, Università del Salento Palazzina A—Centro Ecotekne via Prov, le Lecce Monteroni, 73100 Lecce, Italy;
| | - Luigi De Bellis
- Dipartimento di Scienze e Tecnologie Biologiche ed Ambientali, Università del Salento Palazzina A—Centro Ecotekne via Prov, le Lecce Monteroni, 73100 Lecce, Italy;
| |
Collapse
|
8
|
Yao G, Ji F, Chen J, Dai B, Jia L. Nanobody-functionalized conduit with built-in static mixer for specific elimination of cytokines in hemoperfusion. Acta Biomater 2023; 172:260-271. [PMID: 37806373 DOI: 10.1016/j.actbio.2023.09.050] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/04/2023] [Revised: 09/09/2023] [Accepted: 09/28/2023] [Indexed: 10/10/2023]
Abstract
Removing excessively produced cytokines is of paramount significance in blood purification therapy for hypercytokinemia-associated diseases. In this study, we devised a conduit that is modified with nanobodies (Nb) and incorporates static mixers (Nb-SMC) to eliminate surplus cytokines from the bloodstream. The low-pressure-drop (LPD) static mixer, with each unit featuring two 90°-crossed blades, was strategically arranged in a tessellated pattern on the inner wall of the conduit to induce turbulent mixing effects during the flow of blood. This arrangement enhances mass transfer and molecular diffusion, thereby assisting in the identification and elimination of cytokines. By utilizing computational fluid dynamics (CFD) studies, the Nb-SMC was rationally designed and prepared, ensuring an optimal interval between two mixer units (H/G = 2.5). The resulting Nb-SMC exhibited a remarkable selective clearance of IL-17A, reaching up to 85 %. Additionally, the process of Nb immobilization could be adjusted to achieve the simultaneous removal of multiple cytokines from the bloodstream. Notably, our Nb-SMC displayed good blood compatibility without potential adverse effects on the composition of human blood. As the sole documented static mixer-integrated conduit capable of selectively eliminating cytokines at their physiological concentrations, it holds promise in the clinical potential for hypercytokinemia in high-risk patients. STATEMENT OF SIGNIFICANCE: High-efficient cytokines removal in critical care still remains a challenge. The conduit technique we proposed here is a brand-new strategy for cytokines removal in blood purification therapy. On the one hand, nanobody endows the conduit with specific recognition of cytokine, on the other hand, the build-in static mixer enhances the diffusion of antigenic cytokine to the ligand. The combination of these two has jointly achieved the efficient and specific removal of cytokine. This innovative material is the only reported artificial biomaterial capable of selectively eliminating multiple cytokines under conditions close to clinical practice. It has the potential to improve outcomes for patients with hypercytokinemia and reduce the risk of adverse events associated with current treatment modalities.
Collapse
Affiliation(s)
- Guangshuai Yao
- Liaoning Key Laboratory of Molecular Recognition and imaging, School of Bioengineering, Dalian University of Technology, No.2 Linggong Road, Dalian, Liaoning 116023, PR China
| | - Fangling Ji
- Liaoning Key Laboratory of Molecular Recognition and imaging, School of Bioengineering, Dalian University of Technology, No.2 Linggong Road, Dalian, Liaoning 116023, PR China
| | - Jiewen Chen
- Liaoning Key Laboratory of Molecular Recognition and imaging, School of Bioengineering, Dalian University of Technology, No.2 Linggong Road, Dalian, Liaoning 116023, PR China
| | - Bingbing Dai
- Department of Rheumatology and Immunology, Dalian Municipal Central Hospital affiliated with Dalian University of Technology, No.826, Xinan Road Dalian, 116033 Liaoning, PR China
| | - Lingyun Jia
- Liaoning Key Laboratory of Molecular Recognition and imaging, School of Bioengineering, Dalian University of Technology, No.2 Linggong Road, Dalian, Liaoning 116023, PR China.
| |
Collapse
|
9
|
Cavaliere C, Cerrato A, Laganà A, Montone CM, Piovesana S, Taglioni E, Capriotti AL. Dispersive solid phase extraction using a hydrophilic molecularly imprinted polymer for the selective extraction of patulin in apple juice samples. Mikrochim Acta 2023; 190:485. [PMID: 38006439 PMCID: PMC10676307 DOI: 10.1007/s00604-023-06056-8] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/11/2023] [Accepted: 10/17/2023] [Indexed: 11/27/2023]
Abstract
A molecularly imprinted polymer with a specific selectivity for patulin was successfully synthesized. The molecularly imprinted material was prepared using the two functional monomers dopamine and melamine and formaldehyde as the cross-linker. The resulting material possessed a large number of hydrophilic groups, such as hydroxyls, imino groups, and ether linkages. For the first time, uric acid was used as a dummy template for its structural similarity to patulin. Comprehensive characterization and detailed studies of the adsorption process were carried out via adsorption isotherms, while the rate-limiting steps were investigated using adsorption kinetics. Separation, determination, and quantification of patulin were achieved by ultra-high performance liquid chromatography coupled with both photodiode array detection and tandem mass spectrometry. The latter was applied to patulin confirmation in the analysis of real samples. The methodology was validated in 20 apple juice samples. The results showed that the developed hydrophilic molecularly imprinted polymer had high selectivity and specific adsorption towards patulin, with mean recoveries ranging between 85 and 90% and a relative standard deviation lower than 15%. The developed molecularly imprinted polymer exhibited good linearity in the range 1-100 ng mL-1 with coefficient of determination (R2) > 0.99. The limit of detection was 0.5 ng mL-1, and the limit of quantification was 1 ng g-1. The developed method showed a good purification capacity for apple juices due to its hydrophilic nature and the polar interactions established with the target analyte.
Collapse
Affiliation(s)
- Chiara Cavaliere
- Dipartimento di Chimica, Università di Roma La Sapienza, Piazzale Aldo Moro 5, 00185, Rome, Italy
| | - Andrea Cerrato
- Dipartimento di Chimica, Università di Roma La Sapienza, Piazzale Aldo Moro 5, 00185, Rome, Italy
| | - Aldo Laganà
- Dipartimento di Chimica, Università di Roma La Sapienza, Piazzale Aldo Moro 5, 00185, Rome, Italy
| | - Carmela Maria Montone
- Dipartimento di Chimica, Università di Roma La Sapienza, Piazzale Aldo Moro 5, 00185, Rome, Italy.
| | - Susy Piovesana
- Dipartimento di Chimica, Università di Roma La Sapienza, Piazzale Aldo Moro 5, 00185, Rome, Italy
| | - Enrico Taglioni
- Dipartimento di Chimica, Università di Roma La Sapienza, Piazzale Aldo Moro 5, 00185, Rome, Italy
| | - Anna Laura Capriotti
- Dipartimento di Chimica, Università di Roma La Sapienza, Piazzale Aldo Moro 5, 00185, Rome, Italy
| |
Collapse
|
10
|
Wright EJ, Meija J, McCarron P, Miles CO. Preparation of 18O-labelled azaspiracids for accurate quantitation using liquid chromatography-mass spectrometry. Anal Bioanal Chem 2023; 415:5973-5983. [PMID: 37530793 PMCID: PMC10556123 DOI: 10.1007/s00216-023-04868-4] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/07/2023] [Revised: 07/13/2023] [Accepted: 07/14/2023] [Indexed: 08/03/2023]
Abstract
Azaspiracids (AZAs) are a group of polyether marine algal toxins known to accumulate in shellfish, posing a risk to human health and the seafood industry. Analysis of AZAs is typically performed using LC-MS, which can suffer from matrix effects that significantly impact the accuracy of measurement results. While the use of isotopic internal standards is an effective approach to correct for these effects, isotopically labelled standards for AZAs are not currently available. In this study, 18O-labelled AZA1, AZA2, and AZA3 were prepared by reaction with H218O under acidic conditions, and the reaction kinetics and sites of incorporation were studied using LC-HRMS/MS aided by mathematical analysis of their isotope patterns. Analysis of the isotopic incorporation in AZA1 and AZA3 indicated the presence of four exchangeable oxygen atoms. Excessive isomerization occurred during preparation of 18O-labelled AZA2, suggesting a role for the 8-methyl group in the thermodynamic stability of AZAs. Neutralized mixtures of 18O-labelled AZA1 and AZA3 were found to maintain their isotopic and isomeric integrities when stored at -20 °C and were used to develop an isotope-dilution LC-MS method which was applied to reference materials of shellfish matrices containing AZAs, demonstrating high accuracy and excellent reproducibility. Preparation of isotopically labelled compounds using the isotopic exchange method, combined with the kinetic analysis, offers a feasible way to obtain isotopically labelled internal standards for a wide variety of biomolecules to support reliable quantitation.
Collapse
Affiliation(s)
- Elliott J. Wright
- Biotoxin Metrology, National Research Council Canada, 1411 Oxford Street, Halifax, NS B3H 3Z1 Canada
| | - Juris Meija
- National Research Council, 1200 Montreal Road, Ottawa, ON K1A 0R6 Canada
| | - Pearse McCarron
- Biotoxin Metrology, National Research Council Canada, 1411 Oxford Street, Halifax, NS B3H 3Z1 Canada
| | - Christopher O. Miles
- Biotoxin Metrology, National Research Council Canada, 1411 Oxford Street, Halifax, NS B3H 3Z1 Canada
| |
Collapse
|
11
|
Martiník J, Boško R, Svoboda Z, Běláková S, Benešová K, Pernica M. Determination of mycotoxins and their dietary exposure assessment in pale lager beers using immunoaffinity columns and UPLC-MS/MS. Mycotoxin Res 2023:10.1007/s12550-023-00492-4. [PMID: 37332076 DOI: 10.1007/s12550-023-00492-4] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/10/2023] [Revised: 05/19/2023] [Accepted: 05/23/2023] [Indexed: 06/20/2023]
Abstract
The use of contaminated raw materials can lead to the transfer of mycotoxins into the final product, including beer. This study describes the use of the commercially available immunoaffinity column 11+Myco MS-PREP® and UPLC-MS/MS for the determination of mycotoxins in pale lager-type beers brewed in Czech Republic and other European countries. The additional aim of the work was to develop, optimize and validate this analytical method. Validation parameters such as linearity, limit of detection (LOD), limit of quantification (LOQ), precision and accuracy were tested. The calibration curves were linear with correlation coefficients (R2 > 0.99) for all mycotoxins under investigation. The LOD ranged from 0.1 to 50 ng/L and LOQ from 0.4 to 167 ng/L. Recoveries of the selected analytes ranged from 72.2 to 101.1%, and the relative standard deviation under conditions repeatability (RSDr) did not exceed 16.3% for any mycotoxin. The validated procedure was successfully applied for the analysis of mycotoxins in a total of 89 beers from the retail network. The results were also processed using advanced chemometric techniques and compared with similar published studies. The toxicological impact was taken into account.
Collapse
Affiliation(s)
- Jan Martiník
- Research Institute of Brewing and Malting. Mostecká 7, 614 00, Brno, Czech Republic
- Institute of Food Chemistry and Biotechnology, Faculty of Chemistry, Brno University of Technology, Purkyňova 118, 612 00, Brno, Czech Republic
- Department of Biotechnology, University of Chemistry and Technology Prague, Technická 5 166 28, Prague 6, Czech Republic
| | - Rastislav Boško
- Research Institute of Brewing and Malting. Mostecká 7, 614 00, Brno, Czech Republic
| | - Zdeněk Svoboda
- Research Institute of Brewing and Malting. Mostecká 7, 614 00, Brno, Czech Republic
- Institute of Food Chemistry and Biotechnology, Faculty of Chemistry, Brno University of Technology, Purkyňova 118, 612 00, Brno, Czech Republic
| | - Sylvie Běláková
- Research Institute of Brewing and Malting. Mostecká 7, 614 00, Brno, Czech Republic
| | - Karolína Benešová
- Research Institute of Brewing and Malting. Mostecká 7, 614 00, Brno, Czech Republic
| | - Marek Pernica
- Research Institute of Brewing and Malting. Mostecká 7, 614 00, Brno, Czech Republic.
| |
Collapse
|
12
|
Dou M, Wang S, Li W, Li Q, Xu J, Li J. High-performance molecularly imprinted polymers grafted magnetic photonic crystal microspheres for selective enrichment of Ochratoxin A. J Chromatogr A 2023; 1695:463932. [PMID: 36972663 DOI: 10.1016/j.chroma.2023.463932] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/10/2022] [Revised: 03/11/2023] [Accepted: 03/14/2023] [Indexed: 03/17/2023]
Abstract
Development of selective enrichment materials for the accurate analysis of ochratoxin a (OTA) in environmental and food samples is an effective way to protect human health. Here, a molecularly imprinted polymer (MIP) known as plastic antibody was synthesized onto the magnetic inverse opal photonic crystal microsphere (MIPCM) using a low-cost dummy template imprinting strategy targeting OTA. The MIP@MIPCM exhibited ultrahigh selectivity with an imprinting factor of 130, high specificity with cross-reactivity factors of 3.3-10.5, and large adsorption capacity of 60.5 μg/mg. Such MIP@MIPCM was used for selective capture of OTA in real samples which was quantified in combination with high-performance liquid chromatography, giving a wide linear detection range of 5-20,000 ng/mL, a detection limit of 0.675 ng/mL, and good recovery rates of 84-116%. Moreover, the MIP@MIPCM can be produced simply and rapidly and is very stable under different environmental conditions and easy to store and transport, so it is an ideal substitute of biological antibody modified materials for the selective enrichment of OTA in real samples.
Collapse
Affiliation(s)
- Menghua Dou
- School of Food Science and Pharmaceutical Engineering, Nanjing Normal University, Nanjing 210023, China
| | - Siwei Wang
- School of Food Science and Pharmaceutical Engineering, Nanjing Normal University, Nanjing 210023, China
| | - Wei Li
- Medical Imaging Center the First Affiliated Hospital, Jinan University, Guangdong 510627, China
| | - Qianjin Li
- School of Food Science and Pharmaceutical Engineering, Nanjing Normal University, Nanjing 210023, China.
| | - Jianhong Xu
- Jiangsu Key Laboratory for Food Quality and Safety-State Key Laboratory Cultivation Base Ministry of Science and Technology, Jiangsu Academy of Agricultural Sciences, Nanjing 210014, China.
| | - Jianlin Li
- School of Food Science and Pharmaceutical Engineering, Nanjing Normal University, Nanjing 210023, China.
| |
Collapse
|
13
|
Ch'ng ACW, Konthur Z, Lim TS. Magnetic Nanoparticle-Based Semi-automated Panning for High-Throughput Antibody Selection. Methods Mol Biol 2023; 2702:291-313. [PMID: 37679626 DOI: 10.1007/978-1-0716-3381-6_15] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 09/09/2023]
Abstract
Bio-panning is a common process involved in recombinant antibody selection against defined targets. The biopanning process aims to isolate specific antibodies against an antigen via affinity selection from a phage display library. In general, antigens are immobilized on solid surfaces such as polystyrene plastic, magnetic beads, and nitrocellulose. For high-throughput selection, semi-automated panning selection allows simultaneous panning against multiple target antigens adapting automated particle processing systems such as the KingFisher Flex. The system setup allows for minimal human intervention for pre- and post-panning steps such as antigen immobilization, phage rescue, and amplification. In addition, the platform is also adaptable to perform polyclonal and monoclonal ELISA for the evaluation process. This chapter will detail the protocols involved from the selection stage until the monoclonal ELISA evaluation with important notes attached at the end of this chapter for optimization and troubleshooting purposes.
Collapse
Affiliation(s)
- Angela Chiew Wen Ch'ng
- Institute for Reseach in Molecular Medicine, Universiti Sains Malaysia, Penang, Malaysia
| | - Zoltán Konthur
- Department of Analytical Chemistry, Reference Materials, Bundesanstalt für Materialforschung und -prüfung (BAM), Berlin, Germany
| | - Theam Soon Lim
- Institute for Reseach in Molecular Medicine, Universiti Sains Malaysia, Penang, Malaysia.
| |
Collapse
|
14
|
Luo S, Liu Y, Guo Q, Wang X, Tian Y, Yang W, Li J, Chen Y. Determination of Zearalenone and Its Derivatives in Feed by Gas Chromatography-Mass Spectrometry with Immunoaffinity Column Cleanup and Isotope Dilution. Toxins (Basel) 2022; 14:toxins14110764. [PMID: 36356014 PMCID: PMC9697342 DOI: 10.3390/toxins14110764] [Citation(s) in RCA: 11] [Impact Index Per Article: 3.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/11/2022] [Revised: 10/02/2022] [Accepted: 11/02/2022] [Indexed: 11/06/2022] Open
Abstract
In this study, a gas chromatography-mass spectrometry (GC-MS) method was established for the determination of zearalenone and its five derivatives in feed, including zearalanone, α-zearalanol, β-zearalanol, α-zearalenol, and β-zearalenol. An effective immunoaffinity column was prepared for sample purification, which was followed by the silane derivatization of the eluate after an immunoaffinity chromatography analysis for target compounds by GC-MS. Matrix effects were corrected by an isotope internal standard of zearalenone in this method. The six analytes had a good linear relationship in the range of 2-500 ng/mL, and the correlation coefficients were all greater than 0.99. The limits of detection (LODs) and limits of quantification (LOQs) were less than 1.5 μg/kg and 5.0 μg/kg, respectively. The average spike recoveries for the six feed matrices ranged from 89.6% to 112.3% with relative standard deviations (RSDs) less than 12.6%. Twenty actual feed samples were analyzed using the established method, and at least one target was detected. The established GC-MS method was proven to be reliable and suitable for the determination of zearalenone and its derivatives in feed.
Collapse
Affiliation(s)
- Sunlin Luo
- State Key Laboratory of Animal Nutrition, College of Animal Science and Technology, China Agricultural University, Beijing 100193, China
| | - Ying Liu
- State Key Laboratory of Animal Nutrition, College of Animal Science and Technology, China Agricultural University, Beijing 100193, China
| | - Qi Guo
- Clover Technology Group Inc., Beijing 100044, China
| | - Xiong Wang
- Clover Technology Group Inc., Beijing 100044, China
| | - Ying Tian
- State Key Laboratory of Animal Nutrition, College of Animal Science and Technology, China Agricultural University, Beijing 100193, China
| | - Wenjun Yang
- State Key Laboratory of Animal Nutrition, College of Animal Science and Technology, China Agricultural University, Beijing 100193, China
| | - Juntao Li
- State Key Laboratory of Animal Nutrition, College of Animal Science and Technology, China Agricultural University, Beijing 100193, China
- Correspondence: (J.L.); (Y.C.)
| | - Yiqiang Chen
- State Key Laboratory of Animal Nutrition, College of Animal Science and Technology, China Agricultural University, Beijing 100193, China
- Correspondence: (J.L.); (Y.C.)
| |
Collapse
|
15
|
Dilute-and-shoot versus clean-up approaches: A comprehensive evaluation for the determination of mycotoxins in nuts by UHPLC-MS/MS. Lebensm Wiss Technol 2022. [DOI: 10.1016/j.lwt.2022.113976] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/21/2022]
|
16
|
Yao X. Acid- and Anion-targeted Fluorescent Molecularly Imprinted Polymers: Recent Advances, Challenges and Perspectives. ARAB J CHEM 2022. [DOI: 10.1016/j.arabjc.2022.104149] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/25/2022] Open
|
17
|
Ezan E, Simon S. Introduction to the Toxins Special Issue: "Antibodies for Toxins: From Detection to Therapeutics". Toxins (Basel) 2022; 14:toxins14050363. [PMID: 35622609 PMCID: PMC9146352 DOI: 10.3390/toxins14050363] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Download PDF] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/10/2022] [Accepted: 05/11/2022] [Indexed: 11/16/2022] Open
Abstract
This Special Issue aims to provide an up-to-date investigation and reviews linked to antibody-based technologies for medical countermeasures and detection/diagnosis tools for toxins [...].
Collapse
|
18
|
Wang S, Shao R, Li W, Li X, Sun J, Jiao S, Dai S, Dou M, Xu R, Li Q, Li J. Three-Dimensional Ordered Macroporous Magnetic Inverse Photonic Crystal Microsphere-Based Molecularly Imprinted Polymer for Selective Capture of Aflatoxin B 1. ACS APPLIED MATERIALS & INTERFACES 2022; 14:18845-18853. [PMID: 35412789 DOI: 10.1021/acsami.2c01014] [Citation(s) in RCA: 11] [Impact Index Per Article: 3.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/14/2023]
Abstract
Development of an efficient detection method to monitor residual mycotoxins in food is very important to ensure food safety, but the complex food matrix seriously affects the detection sensitivity and accuracy. Here, using a three-dimensional ordered macroporous magnetic inverse photonic crystal microsphere (MPCM) as the supporting material, a molecularly imprinted polymer (MIP) that can selectively recognize aflatoxin B1 (AFB1) was synthesized through the dummy template imprinting strategy. The MPCM@MIP prepared by employing 5,7-dimethoxycoumarin as the template and methacrylic acid as the functional monomer displayed selectivity toward AFB1 (imprinting factor of 1.5) and could be used as a solid-phase extraction material. By coupling with high-performance liquid chromatography, an analytical method targeting AFB1 was established and displayed a wide linear range of 5-1000 ng/mL with a low detection limit of 0.4 ng/mL. The method showed a good recovery rate of 73-92% in AFB1-spiked soy sauce and vinegar samples. Moreover, the MPCM@MIP could be separated from the sample solution easily because of its magnetic performance, displaying a promising future not only in the enrichment of AFB1 to improve the detection sensitivity and accuracy but also in the removal of AFB1 from food and environmental samples.
Collapse
Affiliation(s)
- Siwei Wang
- School of Food Science and Pharmaceutical Engineering, Nanjing Normal University, Nanjing 210023, China
| | - Rui Shao
- School of Food Science and Pharmaceutical Engineering, Nanjing Normal University, Nanjing 210023, China
| | - Weiwei Li
- School of Food Science and Pharmaceutical Engineering, Nanjing Normal University, Nanjing 210023, China
| | - Xiang Li
- Nanjing University of Chinese Medicine, Nanjing 210023, China
- School of Food Science and Technology, Jiangnan University, Wuxi 214122, China
| | - Jialong Sun
- School of Food Science and Pharmaceutical Engineering, Nanjing Normal University, Nanjing 210023, China
| | - Saisai Jiao
- School of Food Science and Pharmaceutical Engineering, Nanjing Normal University, Nanjing 210023, China
| | - Shijie Dai
- School of Food Science and Pharmaceutical Engineering, Nanjing Normal University, Nanjing 210023, China
| | - Menghua Dou
- School of Food Science and Pharmaceutical Engineering, Nanjing Normal University, Nanjing 210023, China
| | - Ruimin Xu
- School of Food Science and Pharmaceutical Engineering, Nanjing Normal University, Nanjing 210023, China
| | - Qianjin Li
- School of Food Science and Pharmaceutical Engineering, Nanjing Normal University, Nanjing 210023, China
| | - Jianlin Li
- School of Food Science and Pharmaceutical Engineering, Nanjing Normal University, Nanjing 210023, China
| |
Collapse
|
19
|
Tang Z, Liu F, Fang F, Ding X, Han Q, Tan Y, Peng C. Solid-phase extraction techniques based on nanomaterials for mycotoxin analysis: An overview for food and agricultural products. J Sep Sci 2022; 45:2273-2300. [PMID: 35389521 DOI: 10.1002/jssc.202200067] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/24/2022] [Revised: 04/01/2022] [Accepted: 04/04/2022] [Indexed: 11/06/2022]
Abstract
Mycotoxin contamination is a globally concerned problem for food and agricultural products since it may directly or indirectly induce severe threats to human health. Sensitive and selective screening is an efficient strategy to prevent or reduce human and animal exposure to mycotoxins. However, enormous challenges exist in the determination of mycotoxins, arising from complex sample matrices, trace-level analytes, and the co-occurrence of diverse mycotoxins. Appropriate sample preparation is essential to isolate, purify, and enrich mycotoxins from complicated matrices, thus decreasing sample matrix effects and lowering detection limits. With the cross-disciplinary development, new solid-phase extraction strategies have been exploited and integrated with nanotechnology to meet the challenges of mycotoxin analysis. This review summarizes the advance and progress of solid-phase extraction techniques as the methodological solutions for mycotoxin analysis. Emphases are paid on nanomaterials fabricated as trapping media of SPE techniques, including carbonaceous nanoparticles, metal/metal oxide-based nanoparticles, and nanoporous materials. Advantages and limitations are discussed, along with the potential prospects. This article is protected by copyright. All rights reserved.
Collapse
Affiliation(s)
- Zhentao Tang
- Key Laboratory of Southwestern Chinese Medicine Resources, Innovative Institute of Chinese Medicine and Pharmacy, Chengdu University of Traditional Chinese Medicine, Chengdu, China
| | - Fei Liu
- Technology Center of Chengdu Customs District P. R. China, Chengdu, China
| | - Fang Fang
- Urumqi Customs District P. R. China, Urumqi, China
| | - Xuelu Ding
- School of Pharmacy, Qingdao University, Qingdao, China
| | - Qingrong Han
- Key Laboratory of Southwestern Chinese Medicine Resources, School of Pharmacy, Chengdu University of Traditional Chinese Medicine, Chengdu, China
| | - Yuzhu Tan
- Key Laboratory of Southwestern Chinese Medicine Resources, School of Pharmacy, Chengdu University of Traditional Chinese Medicine, Chengdu, China
| | - Cheng Peng
- Key Laboratory of Southwestern Chinese Medicine Resources, School of Pharmacy, Chengdu University of Traditional Chinese Medicine, Chengdu, China
| |
Collapse
|
20
|
Wang Y, Zhang C, Wang J, Knopp D. Recent Progress in Rapid Determination of Mycotoxins Based on Emerging Biorecognition Molecules: A Review. Toxins (Basel) 2022; 14:73. [PMID: 35202100 PMCID: PMC8874725 DOI: 10.3390/toxins14020073] [Citation(s) in RCA: 15] [Impact Index Per Article: 5.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/20/2021] [Revised: 01/14/2022] [Accepted: 01/15/2022] [Indexed: 12/12/2022] Open
Abstract
Mycotoxins are secondary metabolites produced by fungal species, which pose significant risk to humans and livestock. The mycotoxins which are produced from Aspergillus, Penicillium, and Fusarium are considered most important and therefore regulated in food- and feedstuffs. Analyses are predominantly performed by official laboratory methods in centralized labs by expert technicians. There is an urgent demand for new low-cost, easy-to-use, and portable analytical devices for rapid on-site determination. Most significant advances were realized in the field bioanalytical techniques based on molecular recognition. This review aims to discuss recent progress in the generation of native biomolecules and new bioinspired materials towards mycotoxins for the development of reliable bioreceptor-based analytical methods. After brief presentation of basic knowledge regarding characteristics of most important mycotoxins, the generation, benefits, and limitations of present and emerging biorecognition molecules, such as polyclonal (pAb), monoclonal (mAb), recombinant antibodies (rAb), aptamers, short peptides, and molecularly imprinted polymers (MIPs), are discussed. Hereinafter, the use of binders in different areas of application, including sample preparation, microplate- and tube-based assays, lateral flow devices, and biosensors, is highlighted. Special focus, on a global scale, is placed on commercial availability of single receptor molecules, test-kits, and biosensor platforms using multiplexed bead-based suspension assays and planar biochip arrays. Future outlook is given with special emphasis on new challenges, such as increasing use of rAb based on synthetic and naïve antibody libraries to renounce animal immunization, multiple-analyte test-kits and high-throughput multiplexing, and determination of masked mycotoxins, including stereoisomeric degradation products.
Collapse
Affiliation(s)
- Yanru Wang
- College of Food Science and Engineering, Northwest A&F University, Yangling, Xianyang 712100, China; (Y.W.); (C.Z.)
| | - Cui Zhang
- College of Food Science and Engineering, Northwest A&F University, Yangling, Xianyang 712100, China; (Y.W.); (C.Z.)
| | - Jianlong Wang
- College of Food Science and Engineering, Northwest A&F University, Yangling, Xianyang 712100, China; (Y.W.); (C.Z.)
| | - Dietmar Knopp
- Chair for Analytical Chemistry and Water Chemistry, Institute of Hydrochemistry, Technische Universitat München, Elisabeth-Winterhalter-Weg 6, D-81377 München, Germany
| |
Collapse
|
21
|
|
22
|
Yao G, Huang C, Ji F, Ren J, Zang B, Jia L. Nanobody-loaded immunosorbent for highly-specific removal of interleukin-17A from blood. J Chromatogr A 2021; 1654:462478. [PMID: 34450522 DOI: 10.1016/j.chroma.2021.462478] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/21/2021] [Revised: 08/13/2021] [Accepted: 08/14/2021] [Indexed: 10/20/2022]
Abstract
Elimination of overproduced cytokines from blood can relieve immune system disorders caused by hypercytokinemia. Due to the central roles of interleukin-17A (IL-17A) plays in regulating the immunity and inflammatory responses in humans, here, a novel immunosorbent containing anti-IL-17A nanobodies (Nbs) was constructed for IL-17A removal from blood. The theoretical maximum adsorption capacity estimated from the Langmuir isotherm is up to 11.55 mg/g gel, which is almost consistent with the saturated adsorption capacity determined in dynamic adsorption. The in vitro plasma perfusion test demonstrated a remarkable adsorptive performance of the Nb-coupled sorbent since more than 75% IL-17A could be eliminated under the plasma/sorbent ratio of 1000:1. These results indicated the Nb-loaded immunosorbent can provide a simple and economic platform technology for immunoaffinity depletion of single or even multiple cytokines from plasma.
Collapse
Affiliation(s)
- Guangshuai Yao
- Liaoning Key Laboratory of Molecular Recognition and imaging, School of Bioengineering, Dalian University of Technology, No.2 Linggong Road, Dalian, Liaoning 116023, PR China
| | - Chundong Huang
- Liaoning Key Laboratory of Molecular Recognition and imaging, School of Bioengineering, Dalian University of Technology, No.2 Linggong Road, Dalian, Liaoning 116023, PR China
| | - Fangling Ji
- Liaoning Key Laboratory of Molecular Recognition and imaging, School of Bioengineering, Dalian University of Technology, No.2 Linggong Road, Dalian, Liaoning 116023, PR China
| | - Jun Ren
- Liaoning Key Laboratory of Molecular Recognition and imaging, School of Bioengineering, Dalian University of Technology, No.2 Linggong Road, Dalian, Liaoning 116023, PR China
| | - Berlin Zang
- Liaoning Key Laboratory of Molecular Recognition and imaging, School of Bioengineering, Dalian University of Technology, No.2 Linggong Road, Dalian, Liaoning 116023, PR China
| | - Lingyun Jia
- Liaoning Key Laboratory of Molecular Recognition and imaging, School of Bioengineering, Dalian University of Technology, No.2 Linggong Road, Dalian, Liaoning 116023, PR China.
| |
Collapse
|
23
|
Wang ZY, Wu HL, Chang YY, Wang T, Chen W, Tong GY, Yu RQ. Simultaneous determination of nine tyrosine kinase inhibitors in three complex biological matrices by using high-performance liquid chromatography-diode array detection combined with a second-order calibration method. J Sep Sci 2021; 44:3914-3923. [PMID: 34463059 DOI: 10.1002/jssc.202100293] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/12/2021] [Revised: 08/18/2021] [Accepted: 08/23/2021] [Indexed: 11/08/2022]
Abstract
An intelligent chemometric second-order calibration method called alternating trilinear decomposition- assisted multivariate curve resolution combined with high-performance liquid chromatography-diode array detection was used for the simultaneous quantification of nine tyrosine kinase inhibitors in three complex biological systems. The method allows simultaneous quantification of the components in different biological matrices without the need for cumbersome pre-treatment steps, complex elution conditions, and complete peak separation. Even with the varying time shift, severe peak overlap, and various unknown interferences, the proposed method can extract pure chromatographic and spectroscopic information for each analyte, while providing accurate qualitative and quantitative results of nine common tyrosine kinase inhibitors in three different biological matrices. All the drugs were eluted in 7 min. The results showed that the nine drugs in each matrix showed good linearity (r > 0.984) in the calibration range with a root mean square error of calibration less than 0.9 μg/mL. The average spiked recoveries of the target analytes were all in the range of 83.4-110.0%, with standard deviations less than 9.0%. Finally, the classical method was used to validate the proposed method. In comparison to the traditional method, the proposed strategy is accuracy, simultaneous, and interference-free.
Collapse
Affiliation(s)
- Zhao-Yang Wang
- State Key Laboratory of Chemo/Biosensing and Chemometrics, College of Chemistry and Chemical Engineering, Hunan University, Changsha, P. R. China
| | - Hai-Long Wu
- State Key Laboratory of Chemo/Biosensing and Chemometrics, College of Chemistry and Chemical Engineering, Hunan University, Changsha, P. R. China
| | - Yue-Yue Chang
- State Key Laboratory of Chemo/Biosensing and Chemometrics, College of Chemistry and Chemical Engineering, Hunan University, Changsha, P. R. China
| | - Tong Wang
- State Key Laboratory of Chemo/Biosensing and Chemometrics, College of Chemistry and Chemical Engineering, Hunan University, Changsha, P. R. China
| | - Wei Chen
- State Key Laboratory of Chemo/Biosensing and Chemometrics, College of Chemistry and Chemical Engineering, Hunan University, Changsha, P. R. China
| | - Gao-Yan Tong
- State Key Laboratory of Chemo/Biosensing and Chemometrics, College of Chemistry and Chemical Engineering, Hunan University, Changsha, P. R. China
| | - Ru-Qin Yu
- State Key Laboratory of Chemo/Biosensing and Chemometrics, College of Chemistry and Chemical Engineering, Hunan University, Changsha, P. R. China
| |
Collapse
|
24
|
Bouvarel T, Delaunay N, Pichon V. Molecularly imprinted polymers in miniaturized extraction and separation devices. J Sep Sci 2021; 44:1727-1751. [DOI: 10.1002/jssc.202001223] [Citation(s) in RCA: 13] [Impact Index Per Article: 3.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/10/2020] [Revised: 01/18/2021] [Accepted: 01/20/2021] [Indexed: 12/20/2022]
Affiliation(s)
- Thomas Bouvarel
- Laboratoire des Sciences Analytiques, Bioanalytiques et Miniaturisation—UMR Chimie Biologie Innovation 8231, ESPCI Paris, CNRS PSL University Paris 75005 France
| | - Nathalie Delaunay
- Laboratoire des Sciences Analytiques, Bioanalytiques et Miniaturisation—UMR Chimie Biologie Innovation 8231, ESPCI Paris, CNRS PSL University Paris 75005 France
| | - Valérie Pichon
- Laboratoire des Sciences Analytiques, Bioanalytiques et Miniaturisation—UMR Chimie Biologie Innovation 8231, ESPCI Paris, CNRS PSL University Paris 75005 France
- Sorbonne Université Paris 75005 France
| |
Collapse
|