1
|
Li J, Wang M, Jia R, Ma Z, Zhang X, Li J, Xiao X, Zhou Y, Wang Q. Graphene-Coated Iron Nitride Streptavidin Magnetic Beads: Preparation and Application in SARS-CoV-2 Enrichment. Magnetochemistry 2022; 8:41. [DOI: 10.3390/magnetochemistry8040041] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 02/05/2023]
Abstract
In this study, we prepared a streptavidin magnetic bead based on graphene-coated iron nitride magnetic beads (G@FeN-MB) and tried to use it for the enrichment of severe acute respiratory syndrome coronavirus-2 (SARS-CoV-2). The outer shell of our magnetic bead was wrapped with multiple graphene sheets, and there is no report on the application of graphene to the magnetic-bead-coating material. First, the graphene shell of G@FeN-MB was oxidized by a modified Hummer method so as to generate the carboxyl groups required for the coupling of streptavidin (SA) on the surface of the magnetic beads. X-ray photoelectron spectroscopy (XPS), Raman spectroscopy, Fourier transform infrared spectroscopy (FTIR), and transmission electron microscopy (TEM) were used to characterize the oxidized G@FeN-MB (GO@FeN-MB). Streptavidin was then linked to the surface of the GO@FeN-MB by coupling the amino of the streptavidin with the carboxyl on the magnetic beads by carbodiimide method; thus, the streptavidin magnetic beads (SAMBs) were successfully prepared. To prove the practicality of the SAMBs, biotinylated SARS-CoV-2 S1 antibody was linked with it to respectively capture SARS-CoV-2 Spike-protein-coupled polystyrene beads (S-PS) and pseudovirus with S-protein expressed. Microplate reader and fluorescence microscope results show that the SAMBs can effectively enrich viruses. In conclusion, the preparation of SAMBs with G@FeN-MB is feasible and has potential for application in the field of virus enrichment.
Collapse
|
2
|
Wang N, Tesfaluul N, Li J, Gao X, Liu S, Yue B. Enrichment of circulating myeloma cells by immunomagnetic beads combined with flow cytometry for monitoring minimal residual disease and relapse in patients with multiple myeloma. Ann Hematol 2019; 98:2769-2780. [PMID: 31748925 DOI: 10.1007/s00277-019-03833-5] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/16/2018] [Accepted: 10/28/2019] [Indexed: 12/14/2022]
Abstract
Difficulty in regularly analyzing marrow myeloma cells (MMCs) and low frequency of circulating myeloma cells (CMCs) in blood presents challenges for monitoring minimal residual disease (MRD) in multiple myeloma (MM). We have developed a set of method for enrichment of CMCs by immunomagetic beads (IMB) combined with flow cytometry (IMB-FCM) based on CD38-APC/CD138-APC antibodies in U266-spiked samples and in 122 patient samples. U266 cell capture efficiency of CD38/CD138-IMB-FCM (6.960, 2.574) was 6- and 2-fold higher than that of FCM (1.032), and the sensitivity of FCM and IMB-FCM was 0.01% and 0.001%, respectively. In MM cohort, the positive rate of CMCs by IMB-FCM increased from 60.5~70.0 to 85~87.2% in newly diagnosed/relapsed and partial remission (PR) patients compared with by FCM (P < 0.05). Two complete remission (CR) patients contain certain amounts of CMCs by IMB-FCM while no CMCs and MMCs were detectable by FCM. Patients exhibiting PR and CR upon therapy had much lower CMC and MMC counts than newly diagnosed/relapsed patients (P < 0.005). Based on MRD measurement in BM and PB samples, all FCM-negative BM samples were also paired with FCM/IMB-FCM-negative PB samples among newly diagnosed, relapsed, and PR patients, and FCM-positive BM samples were accompanied by IMB-FCM-positive results in 88% of corresponding PB samples. CMCs strongly associated with other clinical biomarkers of disease burden, including elevated MMCs, β2-MG, sCrea, and DS and ISS stages, and more serious anemia, bone destruction, and renal impairment (P < 0.05). Logistic regression analysis revealed that elevated β2-MG and moderate-to-more anemia were significant risk factors for the presence of CMCs (P < 0.05). As a noninvasive "liquid biopsy" of monitoring MRD, the potential of IMB-FCM for CMC detection may complement or minimize bone marrow aspiration in future treatment of MM patients.
Collapse
Affiliation(s)
- Ningning Wang
- Department of Laboratory Medicine, the First Affiliated Hospital of Zhengzhou University, Zhengzhou, Henan, China.,Department of Laboratory Medicine, the First People's Hospital of Pingdingshan, Pingdingshan, Henan, China
| | - Nahom Tesfaluul
- Department of Oncology, the First Affiliated Hospital of Zhengzhou University, Zhengzhou, Henan, China
| | - Jia Li
- Department of Laboratory Medicine, the First Affiliated Hospital of Zhengzhou University, Zhengzhou, Henan, China
| | - Xiaojuan Gao
- Department of Laboratory Medicine, the First Affiliated Hospital of Zhengzhou University, Zhengzhou, Henan, China
| | - Shuai Liu
- Department of Laboratory Medicine, the First Affiliated Hospital of Zhengzhou University, Zhengzhou, Henan, China.,Faculty of Laboratory Medicine, Zhengzhou University, Zhengzhou, Henan, China.,Key Laboratory Medicine of Henan Province, Faculty of Laboratory Medicine, Zhengzhou University, Zhengzhou, Henan, China
| | - Baohong Yue
- Department of Laboratory Medicine, the First Affiliated Hospital of Zhengzhou University, Zhengzhou, Henan, China. .,Faculty of Laboratory Medicine, Zhengzhou University, Zhengzhou, Henan, China. .,Key Laboratory Medicine of Henan Province, Faculty of Laboratory Medicine, Zhengzhou University, Zhengzhou, Henan, China. .,Open Laboratory, Henan Province Key Subject of Clinical Medicine, Zhengzhou, Henan, China.
| |
Collapse
|
3
|
Kuhn P, Thiem S, Steinert M, Purvis D, Lugmayr V, Treutlein U, Plobner L, Leiser RM, Hust M, Dübel S. Human Anti-Lipopolysaccharid (LPS) antibodies against Legionella with high species specificity. Hum Antibodies 2017; 26:29-38. [PMID: 28582852 DOI: 10.3233/hab-170318] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 06/07/2023]
Abstract
Legionella are Gram-negative bacteria that are ubiquitously present in natural and man-made water reservoirs. When humans inhale aerosolized water contaminated with Legionella, alveolar macrophages can be infected, which may lead to a life-threatening pneumonia called Legionnaires' disease. Due to the universal distribution of Legionella in water and their potential threat to human health, the Legionella concentration in water for human use must be strictly monitored, which is difficult since the standard detection still relies on lengthy cultivation and analysis of bacterial morphology. In this study, an antibody against L. pneumophila has been generated from the naïve human HAL antibody libraries by phage-display for the first time. The panning was performed on whole bacterial cells in order to select antibodies that bind specifically to the cell surface of untreated Legionella. The bacterial cell wall component lipopolysaccharide (LPS) was identified as the target structure. Specific binding to the important pathogenic L. pneumophila strains Corby, Philadelphia-1 and Knoxville was observed, while no binding was detected to seven members of the families Enterobacteriaceae, Pseudomonadaceae or Clostridiaceae. Production of this antibody in the recombinant scFv-Fc format using either a murine or a human Fc part allowed the set-up of a sandwich-ELISA for detection of Legionella cells. The scFv-Fc construct proved to be very stable, even when stored for several weeks at elevated temperatures. A sensitivity limit of 4,000 cells was achieved. The scFv-Fc antibody pair was integrated on a biosensor, demonstrating the specific and fast detection of L. pneumophila on a portable device. With this system, 10,000 Legionella cells were detected within 35 min. Combined with a water filtration/concentration system, this antibody may be developed into a promising reagent for rapid on-site Legionella monitoring.
Collapse
Affiliation(s)
- Philipp Kuhn
- Biotechnology and Bioinformatics, Institute for Biochemistry, Technische Universität Braunschweig, Braunschweig, Germany
- YUMAB GmbH, Rebenring, Braunschweig, Germany
| | - Stefanie Thiem
- Institute for Microbiology, Technische Universität Braunschweig, Braunschweig, Germany
- Department of Animal Breeding and Genetics, University of Veterinary Medicine Vienna, Vienna, Austria
| | - Michael Steinert
- Institute for Microbiology, Technische Universität Braunschweig, Braunschweig, Germany
- Helmholtz Center for Infection Research, Braunschweig, Germany
| | | | | | | | | | | | - Michael Hust
- Biotechnology and Bioinformatics, Institute for Biochemistry, Technische Universität Braunschweig, Braunschweig, Germany
| | - Stefan Dübel
- Biotechnology and Bioinformatics, Institute for Biochemistry, Technische Universität Braunschweig, Braunschweig, Germany
| |
Collapse
|
4
|
|
5
|
Díaz-Flores Á, Montero JC, Castro FJ, Alejandres EM, Bayón C, Solís I, Fernández-Lafuente R, Rodríguez G. Comparing methods of determining Legionella spp. in complex water matrices. BMC Microbiol 2015; 15:91. [PMID: 25925400 PMCID: PMC4436101 DOI: 10.1186/s12866-015-0423-7] [Citation(s) in RCA: 26] [Impact Index Per Article: 2.9] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/18/2014] [Accepted: 04/15/2015] [Indexed: 12/01/2022] Open
Abstract
BACKGROUND Legionella testing conducted at environmental laboratories plays an essential role in assessing the risk of disease transmission associated with water systems. However, drawbacks of culture-based methodology used for Legionella enumeration can have great impact on the results and interpretation which together can lead to underestimation of the actual risk. Up to 20% of the samples analysed by these laboratories produced inconclusive results, making effective risk management impossible. Overgrowth of competing microbiota was reported as an important factor for culture failure. For quantitative polymerase chain reaction (qPCR), the interpretation of the results from the environmental samples still remains a challenge. Inhibitors may cause up to 10% of inconclusive results. This study compared a quantitative method based on immunomagnetic separation (IMS method) with culture and qPCR, as a new approach to routine monitoring of Legionella. RESULTS First, pilot studies evaluated the recovery and detectability of Legionella spp using an IMS method, in the presence of microbiota and biocides. The IMS method results were not affected by microbiota while culture counts were significantly reduced (1.4 log) or negative in the same samples. Damage by biocides of viable Legionella was detected by the IMS method. Secondly, a total of 65 water samples were assayed by all three techniques (culture, qPCR and the IMS method). Of these, 27 (41.5%) were recorded as positive by at least one test. Legionella spp was detected by culture in 7 (25.9%) of the 27 samples. Eighteen (66.7%) of the 27 samples were positive by the IMS method, thirteen of them reporting counts below 10(3) colony forming units per liter (CFU l(-1)), six presented interfering microbiota and three presented PCR inhibition. Of the 65 water samples, 24 presented interfering microbiota by culture and 8 presented partial or complete inhibition of the PCR reaction. So the rate of inconclusive results of culture and PCR was 36.9 and 12.3%, respectively, without any inconclusive results reported for the IMS method. CONCLUSION The IMS method generally improved the recovery and detectability of Legionella in environmental matrices, suggesting the possibility to use IMS method as valuable indicator of risk. Thus, this method may significantly improve our knowledge about the exposure risk to these bacteria, allowing us to implement evidence-based monitoring and disinfection strategies.
Collapse
Affiliation(s)
- Álvaro Díaz-Flores
- Departamento de Microbiología General III, Facultad de Ciencias Biológicas, Universidad Complutense de Madrid, Campus Moncloa, 28040, Madrid, Spain.
| | - Juan Carlos Montero
- Instituto de Ciencias de la Salud Ctra, de Extremadura Km. 114, 45600, Talavera de la Reina, Spain.
| | - Francisco Javier Castro
- Laboratorio Regional de Salud Pública Consejería de Sanidad y Consumo/Comunidad de Madrid, C/ Sierra del Alquife N 8, 2 Planta, 28053, Madrid, Spain.
| | - Eva María Alejandres
- Laboratorio Regional de Salud Pública Consejería de Sanidad y Consumo/Comunidad de Madrid, C/ Sierra del Alquife N 8, 2 Planta, 28053, Madrid, Spain.
| | - Carmen Bayón
- Laboratorio Regional de Salud Pública Consejería de Sanidad y Consumo/Comunidad de Madrid, C/ Sierra del Alquife N 8, 2 Planta, 28053, Madrid, Spain.
| | | | - Roberto Fernández-Lafuente
- Departamento de Biocatálisis, Instituto de Catálisis y Petroleoquímica, Consejo Superior de Investigaciones Científicas, Campus UAM-CSIC, 28049, Cantoblanco, Madrid, Spain.
| | - Guillermo Rodríguez
- Biótica, Bioquímica Analítica, S.L, Science and Technology Park of Jaume I University, Campus RiuSec - Espaitec 2, planta baja, E12071, Castellón de la Plana, Spain.
| |
Collapse
|
6
|
Abstract
Legionnaires' disease (LD) is an often severe and potentially fatal form of bacterial pneumonia caused by an extensive list of Legionella species. These ubiquitous freshwater and soil inhabitants cause human respiratory disease when amplified in man-made water or cooling systems and their aerosols expose a susceptible population. Treatment of sporadic cases and rapid control of LD outbreaks benefit from swift diagnosis in concert with discriminatory bacterial typing for immediate epidemiological responses. Traditional culture and serology were instrumental in describing disease incidence early in its history; currently, diagnosis of LD relies almost solely on the urinary antigen test, which captures only the dominant species and serogroup, Legionella pneumophila serogroup 1 (Lp1). This has created a diagnostic "blind spot" for LD caused by non-Lp1 strains. This review focuses on historic, current, and emerging technologies that hold promise for increasing LD diagnostic efficiency and detection rates as part of a coherent testing regimen. The importance of cooperation between epidemiologists and laboratorians for a rapid outbreak response is also illustrated in field investigations conducted by the CDC with state and local authorities. Finally, challenges facing health care professionals, building managers, and the public health community in combating LD are highlighted, and potential solutions are discussed.
Collapse
Affiliation(s)
- Jeffrey W Mercante
- Pneumonia Response and Surveillance Laboratory, Respiratory Diseases Branch, U.S. Centers for Disease Control and Prevention, Atlanta, Georgia, USA
| | - Jonas M Winchell
- Pneumonia Response and Surveillance Laboratory, Respiratory Diseases Branch, U.S. Centers for Disease Control and Prevention, Atlanta, Georgia, USA
| |
Collapse
|
7
|
Féraudet-Tarisse C, Vaisanen-Tunkelrott ML, Moreau K, Lamourette P, Créminon C, Volland H. Pathogen-free screening of bacteria-specific hybridomas for selecting high-quality monoclonal antibodies against pathogen bacteria as illustrated for Legionella pneumophila. J Immunol Methods 2013; 391:81-94. [PMID: 23454033 DOI: 10.1016/j.jim.2013.02.012] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [What about the content of this article? (0)] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/02/2012] [Revised: 02/19/2013] [Accepted: 02/21/2013] [Indexed: 11/20/2022]
Abstract
Antibodies are potent biological tools increasingly used as detection, diagnostic and therapeutic reagents. Many technological advances have optimized and facilitated production and screening of monoclonal antibodies. We report here an original method to screen for antibodies targeting biosafety level 2 or 3 pathogens without the fastidious handling inherent to pathogen use. A double ELISA screening was performed using as coated antigen transformed Escherichia coli expressing at its surface a protein specific to the pathogenic bacteria versus control untransformed E. coli. This method was applied to Legionella, using the surface-exposed Mip protein (macrophage infectivity potentiator). This screening proved to be an excellent means of selecting mAbs that bind Legionella pneumophila 1 surface-exposed Mip protein. This method also appears more biologically relevant than screening using the recombinant Mip protein alone and less tedious than a test performed directly on Legionella bacteria. We obtained 21 mAbs that bind strongly to L. pneumophila serogroups 1 to 13, and we validated their use in a rapid ELISA (performed in 4.5 h) and an immunochromatographic test (20 min).
Collapse
|
8
|
Safarik I, Horska K, Pospiskova K, Safarikova M. Magnetic techniques for the detection and determination of xenobiotics and cells in water. Anal Bioanal Chem 2012; 404:1257-73. [DOI: 10.1007/s00216-012-6056-x] [Citation(s) in RCA: 21] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [What about the content of this article? (0)] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/15/2012] [Revised: 04/15/2012] [Accepted: 04/16/2012] [Indexed: 10/28/2022]
|