1
|
Matsuda N, Tanida J, Naruse M, Horisaki R. Noninvasive holographic imaging through dynamically scattering media. Opt Lett 2024; 49:2389-2392. [PMID: 38691726 DOI: 10.1364/ol.516083] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 12/21/2023] [Accepted: 03/26/2024] [Indexed: 05/03/2024]
Abstract
We present a noninvasive method for quantitative phase imaging through dynamically scattering media. A complex amplitude object, illuminated with coherent light, is captured through a dynamically scattering medium and a variable coded aperture, without the need for interferometric measurements or imaging optics. The complex amplitude of the object is computationally retrieved from intensity images that use multiple coded aperture patterns, employing a stochastic gradient descent algorithm. We demonstrate the proposed method both numerically and experimentally.
Collapse
|
2
|
Sun A, He X, Jiang Z, Kong Y, Wang S, Liu C. Phase flow cytometry with coherent modulation imaging. J Biophotonics 2023:e202300057. [PMID: 37039822 DOI: 10.1002/jbio.202300057] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 02/20/2023] [Revised: 03/27/2023] [Accepted: 04/05/2023] [Indexed: 06/19/2023]
Abstract
Label-free imaging and identification of fast-moving cells is a very challenging task. A kind of phase flow cytometry using coherent modulation imaging was proposed to realize label-free imaging and identification on fast-moving cells with compact optical alignment and high accuracy. Phase image of cells under inspection could be computed qualitatively from their diffraction patterns at the accuracy of about 0.01 wavelength and the resolution of about 1.23 μm and the view field of 0.126 mm2 . Since the imaging system was mainly composed by a piece of random phase plate a detector without using commonly adopted reference beam and corresponding complex optical alignment, this method has much compacter optical structure and much higher tolerance capability to environmental instability in comparison with other kinds of phase flow cytometry. Current experimental results prove it could be an efficient optical tool for label-free tumor cell detection.
Collapse
Affiliation(s)
- Aihui Sun
- Department of Optoelectronic Information Science and Engineering, School of Science, Jiangnan University, Wuxi, Jiangsu, China
| | - Xiaoliang He
- Department of Optoelectronic Information Science and Engineering, School of Science, Jiangnan University, Wuxi, Jiangsu, China
| | - Zhilong Jiang
- Department of Optoelectronic Information Science and Engineering, School of Science, Jiangnan University, Wuxi, Jiangsu, China
| | - Yan Kong
- Department of Optoelectronic Information Science and Engineering, School of Science, Jiangnan University, Wuxi, Jiangsu, China
| | - Shouyu Wang
- Department of Optoelectronic Information Science and Engineering, School of Science, Jiangnan University, Wuxi, Jiangsu, China
| | - Cheng Liu
- Department of Optoelectronic Information Science and Engineering, School of Science, Jiangnan University, Wuxi, Jiangsu, China
- Shanghai Institute of Optics and Fine Mechanics, Chinese Academy of Sciences, Shanghai, China
| |
Collapse
|
3
|
Nawaz AA, Soteriou D, Xu CK, Goswami R, Herbig M, Guck J, Girardo S. Image-based cell sorting using focused travelling surface acoustic waves. Lab Chip 2023; 23:372-387. [PMID: 36620943 PMCID: PMC9844123 DOI: 10.1039/d2lc00636g] [Citation(s) in RCA: 1] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 07/11/2022] [Accepted: 11/21/2022] [Indexed: 05/27/2023]
Abstract
Sorting cells is an essential primary step in many biological and clinical applications such as high-throughput drug screening, cancer research and cell transplantation. Cell sorting based on their mechanical properties has long been considered as a promising label-free biomarker that could revolutionize the isolation of cells from heterogeneous populations. Recent advances in microfluidic image-based cell analysis combined with subsequent label-free sorting by on-chip actuators demonstrated the possibility of sorting cells based on their physical properties. However, the high purity of sorting is achieved at the expense of a sorting rate that lags behind the analysis throughput. Furthermore, stable and reliable system operation is an important feature in enabling the sorting of small cell fractions from a concentrated heterogeneous population. Here, we present a label-free cell sorting method, based on the use of focused travelling surface acoustic wave (FTSAW) in combination with real-time deformability cytometry (RT-DC). We demonstrate the flexibility and applicability of the method by sorting distinct blood cell types, cell lines and particles based on different physical parameters. Finally, we present a new strategy to sort cells based on their mechanical properties. Our system enables the sorting of up to 400 particles per s. Sorting is therefore possible at high cell concentrations (up to 36 million per ml) while retaining high purity (>92%) for cells with diverse sizes and mechanical properties moving in a highly viscous buffer. Sorting of small cell fraction from a heterogeneous population prepared by processing of small sample volume (10 μl) is also possible and here demonstrated by the 667-fold enrichment of white blood cells (WBCs) from raw diluted whole blood in a continuous 10-hour sorting experiment. The real-time analysis of multiple parameters together with the high sensitivity and high-throughput of our method thus enables new biological and therapeutic applications in the future.
Collapse
Affiliation(s)
- Ahmad Ahsan Nawaz
- Max Planck Institute for the Science of Light & Max-Planck-Zentrum für Physik und Medizin, Erlangen, Germany.
| | - Despina Soteriou
- Max Planck Institute for the Science of Light & Max-Planck-Zentrum für Physik und Medizin, Erlangen, Germany.
| | - Catherine K Xu
- Max Planck Institute for the Science of Light & Max-Planck-Zentrum für Physik und Medizin, Erlangen, Germany.
| | - Ruchi Goswami
- Max Planck Institute for the Science of Light & Max-Planck-Zentrum für Physik und Medizin, Erlangen, Germany.
| | - Maik Herbig
- Department of Chemistry, University of Tokyo, Tokyo, Japan
| | - Jochen Guck
- Max Planck Institute for the Science of Light & Max-Planck-Zentrum für Physik und Medizin, Erlangen, Germany.
| | - Salvatore Girardo
- Max Planck Institute for the Science of Light & Max-Planck-Zentrum für Physik und Medizin, Erlangen, Germany.
| |
Collapse
|
4
|
Lee C, Kim S, Hugonnet H, Lee M, Park W, Jeon JS, Park Y. Label-free three-dimensional observations and quantitative characterisation of on-chip vasculogenesis using optical diffraction tomography. Lab Chip 2021; 21:494-501. [PMID: 33492325 DOI: 10.1039/d0lc01061h] [Citation(s) in RCA: 8] [Impact Index Per Article: 2.7] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/25/2023]
Abstract
Label-free, three-dimensional (3D) quantitative observations of on-chip vasculogenesis were achieved using optical diffraction tomography. Exploiting 3D refractive index maps as an intrinsic imaging contrast, the vascular structures, multicellular activities, and subcellular organelles of endothelial cells were imaged and analysed throughout vasculogenesis to characterise mature vascular networks without exogenous labelling.
Collapse
Affiliation(s)
- Chungha Lee
- Department of Physics, Korea Advanced Institute of Science and Technology, Daejeon, 34141, Republic of Korea
| | - Seunggyu Kim
- Department of Mechanical Engineering, Korea Advanced Institute of Science and Technology, Daejeon, 34141, Republic of Korea.
| | - Herve Hugonnet
- Department of Physics, Korea Advanced Institute of Science and Technology, Daejeon, 34141, Republic of Korea
| | - Moosung Lee
- Department of Physics, Korea Advanced Institute of Science and Technology, Daejeon, 34141, Republic of Korea
| | - Weisun Park
- Department of Physics, Korea Advanced Institute of Science and Technology, Daejeon, 34141, Republic of Korea
| | - Jessie S Jeon
- Department of Mechanical Engineering, Korea Advanced Institute of Science and Technology, Daejeon, 34141, Republic of Korea. and KAIST Institute for Health Science and Technology, Korea Advanced Institute of Science and Technology, Daejeon, 34141, Republic of Korea
| | - YongKeun Park
- Department of Physics, Korea Advanced Institute of Science and Technology, Daejeon, 34141, Republic of Korea and KAIST Institute for Health Science and Technology, Korea Advanced Institute of Science and Technology, Daejeon, 34141, Republic of Korea and Tomocube Inc., Daejeon, 34109, Republic of Korea
| |
Collapse
|
5
|
Xu T, Lim YJ, Zheng Y, Jung M, Gaus K, Gardiner EE, Lee WM. Modified inverted selective plane illumination microscopy for sub-micrometer imaging resolution in polydimethylsiloxane soft lithography devices. Lab Chip 2020; 20:3960-3969. [PMID: 32940306 DOI: 10.1039/d0lc00598c] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/22/2023]
Abstract
Moldable, transparent polydimethylsiloxane (PDMS) elastomer microdevices enable a broad range of complex studies of three-dimensional cellular networks in their microenvironment in vitro. However, the uneven distribution of refractive index change, external to PDMS devices and internally in the sample chamber, creates a significant optical path difference (OPD) that distorts the light sheet beam and so restricts diffraction limited performance. We experimentally showed that an OPD of 120 μm results in the broadening of the lateral point spread function by over 4-fold. In this paper, we demonstrate steps to adapt a commercial inverted selective plane illumination microscope (iSPIM) and remove the OPD so as to achieve sub-micrometer imaging ranging from 0.6 ± 0.04 μm to 0.91 ± 0.03 μm of a fluorescence biological sample suspended in regular saline (RI ≈1.34) enclosed in 1.2 to 2 mm thick micromolded PDMS microdevices. We have proven that the removal of the OPD from the external PDMS layer by refractive index (RI) matching with a readily accessible, inexpensive sucrose solution is critical to achieve a >3-fold imaging resolution improvement. To monitor the RI matching process, a single-mode fiber (SMF) illuminator was integrated into the iSPIM. To remove the OPD inside the PDMS channel, we used an electrically tunable lens (ETL) that par-focuses the light sheet beam with the detection objective lens and so minimised axial distortions to attain sub-micrometer imaging resolution. We termed this new light sheet imaging protocol as modified inverted selective plane illumination microscopy (m-iSPIM). Using the high spatial-temporal 3D imaging of m-iSPIM, we experimentally captured single platelet (≈2 μm) recruitment to a platelet aggregate (22.5 μm × 22.5 μm × 6 μm) under flow at a 150 μm depth within a microfluidic channel. m-iSPIM paves the way for the application of light sheet imaging to a wide range of 3D biological models in microfluidic devices which recapitulate features of the physiological microenvironment and elucidate subcellular responses.
Collapse
Affiliation(s)
- Tienan Xu
- Research School of Electrical, Energy and Materials Engineering, College of Engineering and Computer Science, The Australian National University, Canberra, ACT 2601, Australia.
| | - Yean Jin Lim
- Research School of Electrical, Energy and Materials Engineering, College of Engineering and Computer Science, The Australian National University, Canberra, ACT 2601, Australia. and ACRF Department of Cancer Biology and Therapeutics, The John Curtin School of Medical Research, The Australian National University, Canberra, ACT 2601, Australia
| | - Yujie Zheng
- Research School of Electrical, Energy and Materials Engineering, College of Engineering and Computer Science, The Australian National University, Canberra, ACT 2601, Australia.
| | - MoonSun Jung
- EMBL Australia Node in Single Molecule Science and ARC Centre of Excellence in Advanced Molecular Imaging, The University of New South Wales, Sydney, NSW 2052, Australia
| | - Katharina Gaus
- EMBL Australia Node in Single Molecule Science and ARC Centre of Excellence in Advanced Molecular Imaging, The University of New South Wales, Sydney, NSW 2052, Australia
| | - Elizabeth E Gardiner
- ACRF Department of Cancer Biology and Therapeutics, The John Curtin School of Medical Research, The Australian National University, Canberra, ACT 2601, Australia
| | - Woei Ming Lee
- Research School of Electrical, Energy and Materials Engineering, College of Engineering and Computer Science, The Australian National University, Canberra, ACT 2601, Australia. and ACRF Department of Cancer Biology and Therapeutics, The John Curtin School of Medical Research, The Australian National University, Canberra, ACT 2601, Australia and ARC Centre of Excellence in Advanced Molecular Imaging, The Australian National University, Canberra, ACT 2601, Australia
| |
Collapse
|
6
|
Hasegawa SY, Miaki T. Whole phase curvature-based particle positioning and size determination by digital holography. Appl Opt 2020; 59:7201-7210. [PMID: 32902483 DOI: 10.1364/ao.394591] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 04/07/2020] [Accepted: 07/18/2020] [Indexed: 06/11/2023]
Abstract
We demonstrate the positioning and characterization of a transparent particle with a diameter of 60 µm in sparse particle fields. Particles appear elongated in optical setups with small numerical apertures that are used in digital holography; thus, an accurate method to position them is required. We propose a new optimization method using the whole phase curvature of a reconstructed wave along the optical axis to obtain not only the precise axial position but also the radius and refractive index of a particle. Experimental results show that the axial positions of particles can be detected with a standard deviation of 38.6 µm, corresponding to 66% of the average particle diameter. A radius of 29.3±0.4µm and a refractive index of 1.5910±0.0017 agree well with the manufacturer specifications of particles.
Collapse
|
7
|
Zhang H, Liu S, Cao L, Brady DJ. Noise suppression for ballistic-photons based on compressive in-line holographic imaging through an inhomogeneous medium. Opt Express 2020; 28:10337-10349. [PMID: 32225621 DOI: 10.1364/oe.385992] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [What about the content of this article? (0)] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 12/17/2019] [Accepted: 03/19/2020] [Indexed: 06/10/2023]
Abstract
Noise suppression is one of the most important tasks in imaging through inhomogeneous mediums. Here, we proposed a denoising approach based on compressive in-line holography for imaging through an inhomogeneous medium. A reference-beam-free system with a low-cost continuous-wave laser is presented. The suppression against the noise, which is brought by the scattering photons, is presented in simulations using the proposed algorithm. The noise immunity is demonstrated in lensless imaging behind a random phase mask with an optical depth of 1.42 by single exposure, as well as behind a ground glass with an optical depth of 6.38 by multiple exposures.
Collapse
|
8
|
Wu Y, Zhou Y, Huang CJ, Kobayashi H, Yan S, Ozeki Y, Wu Y, Sun CW, Yasumoto A, Yatomi Y, Lei C, Goda K. Intelligent frequency-shifted optofluidic time-stretch quantitative phase imaging. Opt Express 2020; 28:519-532. [PMID: 32118978 DOI: 10.1364/oe.380679] [Citation(s) in RCA: 8] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [What about the content of this article? (0)] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 10/23/2019] [Accepted: 12/13/2019] [Indexed: 05/24/2023]
Abstract
Optofluidic time-stretch quantitative phase imaging (OTS-QPI) is a powerful tool as it enables high-throughput (>10,000 cell/s) QPI of single live cells. OTS-QPI is based on decoding temporally stretched spectral interferograms that carry the spatial profiles of cells flowing on a microfluidic chip. However, the utility of OTS-QPI is troubled by difficulties in phase retrieval from the high-frequency region of the temporal interferograms, such as phase-unwrapping errors, high instrumentation cost, and large data volume. To overcome these difficulties, we propose and experimentally demonstrate frequency-shifted OTS-QPI by bringing the phase information to the baseband region. Furthermore, to show its boosted utility, we use it to demonstrate image-based classification of leukemia cells with high accuracy over 96% and evaluation of drug-treated leukemia cells via deep learning.
Collapse
|
9
|
Sanjeev A, Kapellner Y, Shabairou N, Gur E, Sinvani M, Zalevsky Z. Non-Invasive Imaging Through Scattering Medium by Using a Reverse Response Wavefront Shaping Technique. Sci Rep 2019; 9:12275. [PMID: 31439914 PMCID: PMC6706411 DOI: 10.1038/s41598-019-48788-9] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/01/2019] [Accepted: 08/01/2019] [Indexed: 11/24/2022] Open
Abstract
Fundamental challenge of imaging through a scattering media has been resolved by various approaches in the past two decades. Optical wavefront shaping technique is one such method in which one shapes the wavefront of light entering a scattering media using a wavefront shaper such that it cancels the scattering effect. It has been the most effective technique in focusing light inside a scattering media. Unfortunately, most of these techniques require direct access to the scattering medium or need to know the scattering properties of the medium beforehand. Through the novel scheme presented on this paper, both the illumination module and the detection are on the same side of the inspected object and the imaging process is a real time fast converging operation. We model the scattering medium being a biological tissue as a matrix having mathematical properties matched to the physical and biological aspects of the sample. In our adaptive optics scheme, we aim to estimate the scattering function and thus to encode the intensity of the illuminating laser light source using DMD (Digital Micromirror Device) with an inverse scattering function of the scattering medium, such that after passing its scattering function a focused beam is obtained. We optimize the pattern to be displayed on the DMD using Particle Swarm Algorithm (PSO) which eventually help in retrieving a 1D object hidden behind the media.
Collapse
Affiliation(s)
- Abhijit Sanjeev
- Faculty of Engineering and the Institute for Nanotechnology and Advanced Materials, Bar-Ilan University, Ramat-Gan, 5290002, Israel. .,EKB Technologies Ltd., Bat Yam, 5951301, Israel.
| | | | - Nadav Shabairou
- Faculty of Engineering and the Institute for Nanotechnology and Advanced Materials, Bar-Ilan University, Ramat-Gan, 5290002, Israel
| | - Eran Gur
- Azrieli College of Engineering, Jerusalem, 9103501, Israel
| | - Moshe Sinvani
- Faculty of Engineering and the Institute for Nanotechnology and Advanced Materials, Bar-Ilan University, Ramat-Gan, 5290002, Israel
| | - Zeev Zalevsky
- Faculty of Engineering and the Institute for Nanotechnology and Advanced Materials, Bar-Ilan University, Ramat-Gan, 5290002, Israel
| |
Collapse
|
10
|
Arandian A, Bagheri Z, Ehtesabi H, Najafi Nobar S, Aminoroaya N, Samimi A, Latifi H. Optical Imaging Approaches to Monitor Static and Dynamic Cell-on-Chip Platforms: A Tutorial Review. Small 2019; 15:e1900737. [PMID: 31087503 DOI: 10.1002/smll.201900737] [Citation(s) in RCA: 17] [Impact Index Per Article: 3.4] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 02/09/2019] [Revised: 04/14/2019] [Indexed: 06/09/2023]
Abstract
Miniaturized laboratories on chip platforms play an important role in handling life sciences studies. The platforms may contain static or dynamic biological cells. Examples are a fixed medium of an organ-on-a-chip and individual cells moving in a microfluidic channel, respectively. Due to feasibility of control or investigation and ethical implications of live targets, both static and dynamic cell-on-chip platforms promise various applications in biology. To extract necessary information from the experiments, the demand for direct monitoring is rapidly increasing. Among different microscopy methods, optical imaging is a straightforward choice. Considering light interaction with biological agents, imaging signals may be generated as a result of scattering or emission effects from a sample. Thus, optical imaging techniques could be categorized into scattering-based and emission-based techniques. In this review, various optical imaging approaches used in monitoring static and dynamic platforms are introduced along with their optical systems, advantages, challenges, and applications. This review may help biologists to find a suitable imaging technique for different cell-on-chip studies and might also be useful for the people who are going to develop optical imaging systems in life sciences studies.
Collapse
Affiliation(s)
- Alireza Arandian
- Laser and Plasma Research Institute, Shahid Beheshti University, Tehran, 1983969411, Iran
| | - Zeinab Bagheri
- Faculty of Life Sciences and Biotechnology, Shahid Beheshti University, Tehran, 1983969411, Iran
| | - Hamide Ehtesabi
- Faculty of Life Sciences and Biotechnology, Shahid Beheshti University, Tehran, 1983969411, Iran
| | - Shima Najafi Nobar
- Faculty of Mechanical Engineering, K. N. Toosi University of Technology, Tehran, 1969764499, Iran
| | - Neda Aminoroaya
- Laser and Plasma Research Institute, Shahid Beheshti University, Tehran, 1983969411, Iran
| | - Ashkan Samimi
- Laser and Plasma Research Institute, Shahid Beheshti University, Tehran, 1983969411, Iran
| | - Hamid Latifi
- Laser and Plasma Research Institute, Shahid Beheshti University, Tehran, 1983969411, Iran
- Department of Physics, Shahid Beheshti University, Tehran, 1983969411, Iran
| |
Collapse
|
11
|
Zhang Y, Liu T, Huang Y, Teng D, Bian Y, Wu Y, Rivenson Y, Feizi A, Ozcan A. Accurate color imaging of pathology slides using holography and absorbance spectrum estimation of histochemical stains. J Biophotonics 2019; 12:e201800335. [PMID: 30353662 DOI: 10.1002/jbio.201800335] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 09/03/2018] [Revised: 10/15/2018] [Accepted: 10/20/2018] [Indexed: 06/08/2023]
Abstract
Holographic microscopy presents challenges for color reproduction due to the usage of narrow-band illumination sources, which especially impacts the imaging of stained pathology slides for clinical diagnoses. Here, an accurate color holographic microscopy framework using absorbance spectrum estimation is presented. This method uses multispectral holographic images acquired and reconstructed at a small number (e.g., three to six) of wavelengths, estimates the absorbance spectrum of the sample, and projects it onto a color tristimulus. Using this method, the wavelength selection is optimized to holographically image 25 pathology slide samples with different tissue and stain combinations to significantly reduce color errors in the final reconstructed images. The results can be used as a practical guide for various imaging applications and, in particular, to correct color distortions in holographic imaging of pathology samples spanning different dyes and tissue types.
Collapse
Affiliation(s)
- Yibo Zhang
- Electrical and Computer Engineering Department, University of California, Los Angeles, California
- Bioengineering Department, University of California, Los Angeles, California
- California NanoSystems Institute (CNSI), University of California, Los Angeles, California
| | - Tairan Liu
- Electrical and Computer Engineering Department, University of California, Los Angeles, California
- Bioengineering Department, University of California, Los Angeles, California
- California NanoSystems Institute (CNSI), University of California, Los Angeles, California
| | - Yujia Huang
- Electrical and Computer Engineering Department, University of California, Los Angeles, California
| | - Da Teng
- Computer Science Department, University of California, Los Angeles, California
| | - Yinxu Bian
- Electrical and Computer Engineering Department, University of California, Los Angeles, California
| | - Yichen Wu
- Electrical and Computer Engineering Department, University of California, Los Angeles, California
- Bioengineering Department, University of California, Los Angeles, California
- California NanoSystems Institute (CNSI), University of California, Los Angeles, California
| | - Yair Rivenson
- Electrical and Computer Engineering Department, University of California, Los Angeles, California
- Bioengineering Department, University of California, Los Angeles, California
- California NanoSystems Institute (CNSI), University of California, Los Angeles, California
| | - Alborz Feizi
- Electrical and Computer Engineering Department, University of California, Los Angeles, California
- Bioengineering Department, University of California, Los Angeles, California
- California NanoSystems Institute (CNSI), University of California, Los Angeles, California
- Department of Biomedical Engineering, Yale University, New Haven, Connecticut
| | - Aydogan Ozcan
- Electrical and Computer Engineering Department, University of California, Los Angeles, California
- Bioengineering Department, University of California, Los Angeles, California
- California NanoSystems Institute (CNSI), University of California, Los Angeles, California
- Department of Surgery, David Geffen School of Medicine, University of California, Los Angeles, California
| |
Collapse
|
12
|
Park HS, Ceballos S, Eldridge WJ, Wax A. Invited Article: Digital refocusing in quantitative phase imaging for flowing red blood cells. APL Photonics 2018; 3:110802. [PMID: 31192306 PMCID: PMC6561492 DOI: 10.1063/1.5043536] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 06/10/2018] [Accepted: 09/07/2018] [Indexed: 05/19/2023]
Abstract
Quantitative phase imaging (QPI) offers high optical path length sensitivity, probing nanoscale features of live cells, but it is typically limited to imaging just few static cells at a time. To enable utility as a biomedical diagnostic modality, higher throughput is needed. To meet this need, methods for imaging cells in flow using QPI are in development. An important need for this application is to enable accurate quantitative analysis. However, this can be complicated when cells shift focal planes during flow. QPI permits digital refocusing since the complex optical field is measured. Here we analyze QPI images of moving red blood cells with an emphasis on choosing a quantitative criterion for digitally refocusing cell images. Of particular interest is the influence of optical absorption which can skew refocusing algorithms. Examples of refocusing of holographic images of flowing red blood cells using different approaches are presented and analyzed.
Collapse
Affiliation(s)
- Han Sang Park
- Department of Biomedical Engineering, Duke University, Durham, North Carolina 27708, USA
| | - Silvia Ceballos
- Department of Biomedical Engineering, Duke University, Durham, North Carolina 27708, USA
| | - Will J Eldridge
- Department of Biomedical Engineering, Duke University, Durham, North Carolina 27708, USA
| | - Adam Wax
- Department of Biomedical Engineering, Duke University, Durham, North Carolina 27708, USA
| |
Collapse
|
13
|
Ban S, Min E, Baek S, Kwon HM, Popescu G, Jung W. Optical properties of acute kidney injury measured by quantitative phase imaging. Biomed Opt Express 2018; 9:921-932. [PMID: 29541494 PMCID: PMC5846539 DOI: 10.1364/boe.9.000921] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 10/13/2017] [Accepted: 01/25/2018] [Indexed: 05/20/2023]
Abstract
The diagnosis of acute kidney disease (AKI) has been examined mainly by histology, immunohistochemistry and western blot. Though these approaches are widely accepted in the field, it has an inherent limitation due to the lack of high-throughput and quantitative information. For a better understanding of prognosis in AKI, we present a new approach using quantitative phase imaging combined with a wide-field scanning platform. Through the phase-delay information from the tissue, we were able to predict a stage of AKI based on various optical properties such as light scattering coefficient and anisotropy. These optical parameters quantify the deterioration process of the AKI model of tissue. Our device would be a very useful tool when it is required to deliver fast feedback of tissue pathology or when diseases are related to mechanical properties such as fibrosis.
Collapse
Affiliation(s)
- Sungbea Ban
- Department of Biomedical Engineering, Ulsan National Institute of Science and Technology (UNIST), Ulsan, South Korea
- These authors contributed equally to this work
| | - Eunjung Min
- Rowland Institute, Harvard University, Boston, Massachusetts, USA
- These authors contributed equally to this work
| | - Songyee Baek
- Department of Biomedical Engineering, Ulsan National Institute of Science and Technology (UNIST), Ulsan, South Korea
| | - Hyug Moo Kwon
- Department of Biological Science, Ulsan National Institute of Science and Technology (UNIST), Ulsan, South Korea
| | - Gabriel Popescu
- Quantitative Light Imaging Laboratory, Department of Electrical and Computer Engineering, Beckman Institute for Advanced Science and Technology, University of Illinois at Urbana-Champaign, Urbana, Illinois 61801, USA
| | - Woonggyu Jung
- Department of Biomedical Engineering, Ulsan National Institute of Science and Technology (UNIST), Ulsan, South Korea
| |
Collapse
|
14
|
Yan K, Xue L, Wang S. Field of view scanning based quantitative interferometric microscopic cytometers for cellular imaging and analysis. Microsc Res Tech 2018; 81:397-407. [PMID: 29315973 DOI: 10.1002/jemt.22991] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/31/2017] [Revised: 11/02/2017] [Accepted: 12/28/2017] [Indexed: 01/20/2023]
Abstract
Microimaging is of great significance in the biological and medical fields, since it can realize observations acting as important references for cellular research and disease diagnosis. However, traditional microscopy only offers qualitative sample contours; moreover, it is difficult to reach large-amount sample observations limited by the fixed field of view (FoV). To realize massive cellular measurements quantitatively, three designed quantitative interferometric microscopic cytometers based on the FoV scanning are introduced and compared in details in this article. These devices not only retrieve the quantitative sample phase distributions in the extended FoV, but also provide the detailed information of massive cells, such as cellular volume, area, and roundness. Considering their capabilities as quantitative imaging and large-amount sampling, it is believed that these quantitative interferometric microscopic cytometers (QIMCs) can be potentially adopted in high-throughput cell imaging and statistical analysis for both the biological and medical applications.
Collapse
Affiliation(s)
- Keding Yan
- School of Electronic Information Engineering, Xi'an Technological University, Xi'an, Shaanxi 710032, China.,Sinmotec LLC, Suzhou, Jiangsu, 215611, China
| | - Liang Xue
- College of Electronics and Information Engineering, Shanghai University of Electric Power, Shanghai 200090, China.,Sinmotec LLC, Suzhou, Jiangsu, 215611, China
| | - Shouyu Wang
- Computational Optics Laboratory, Department of Optoelectric Information Science and Technology, School of Science, Jiangnan University, Wuxi, Jiangsu 214122, China.,Single Molecule Nanometry Laboratory, Nanjing Agricultural University, Nanjing, Jiangsu, 210095, China.,Sinmotec LLC, Suzhou, Jiangsu, 215611, China
| |
Collapse
|
15
|
Zhang Y, Shin Y, Sung K, Yang S, Chen H, Wang H, Teng D, Rivenson Y, Kulkarni RP, Ozcan A. 3D imaging of optically cleared tissue using a simplified CLARITY method and on-chip microscopy. Sci Adv 2017; 3:e1700553. [PMID: 28819645 PMCID: PMC5553818 DOI: 10.1126/sciadv.1700553] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 02/19/2017] [Accepted: 07/12/2017] [Indexed: 05/07/2023]
Abstract
High-throughput sectioning and optical imaging of tissue samples using traditional immunohistochemical techniques can be costly and inaccessible in resource-limited areas. We demonstrate three-dimensional (3D) imaging and phenotyping in optically transparent tissue using lens-free holographic on-chip microscopy as a low-cost, simple, and high-throughput alternative to conventional approaches. The tissue sample is passively cleared using a simplified CLARITY method and stained using 3,3'-diaminobenzidine to target cells of interest, enabling bright-field optical imaging and 3D sectioning of thick samples. The lens-free computational microscope uses pixel super-resolution and multi-height phase recovery algorithms to digitally refocus throughout the cleared tissue and obtain a 3D stack of complex-valued images of the sample, containing both phase and amplitude information. We optimized the tissue-clearing and imaging system by finding the optimal illumination wavelength, tissue thickness, sample preparation parameters, and the number of heights of the lens-free image acquisition and implemented a sparsity-based denoising algorithm to maximize the imaging volume and minimize the amount of the acquired data while also preserving the contrast-to-noise ratio of the reconstructed images. As a proof of concept, we achieved 3D imaging of neurons in a 200-μm-thick cleared mouse brain tissue over a wide field of view of 20.5 mm2. The lens-free microscope also achieved more than an order-of-magnitude reduction in raw data compared to a conventional scanning optical microscope imaging the same sample volume. Being low cost, simple, high-throughput, and data-efficient, we believe that this CLARITY-enabled computational tissue imaging technique could find numerous applications in biomedical diagnosis and research in low-resource settings.
Collapse
Affiliation(s)
- Yibo Zhang
- Electrical Engineering Department, University of California, Los Angeles, Los Angeles, CA 90095, USA
- Bioengineering Department, University of California, Los Angeles, Los Angeles, CA 90095, USA
- California NanoSystems Institute, University of California, Los Angeles, Los Angeles, CA 90095, USA
| | - Yoonjung Shin
- Bioengineering Department, University of California, Los Angeles, Los Angeles, CA 90095, USA
- Division of Dermatology, Department of Medicine, David Geffen School of Medicine, University of California, Los Angeles, Los Angeles, CA 90095 USA
| | - Kevin Sung
- Bioengineering Department, University of California, Los Angeles, Los Angeles, CA 90095, USA
- Division of Dermatology, Department of Medicine, David Geffen School of Medicine, University of California, Los Angeles, Los Angeles, CA 90095 USA
| | - Sam Yang
- Electrical Engineering Department, University of California, Los Angeles, Los Angeles, CA 90095, USA
| | - Harrison Chen
- Bioengineering Department, University of California, Los Angeles, Los Angeles, CA 90095, USA
| | - Hongda Wang
- Electrical Engineering Department, University of California, Los Angeles, Los Angeles, CA 90095, USA
- Bioengineering Department, University of California, Los Angeles, Los Angeles, CA 90095, USA
- California NanoSystems Institute, University of California, Los Angeles, Los Angeles, CA 90095, USA
| | - Da Teng
- Computer Science Department, University of California, Los Angeles, Los Angeles, CA 90095, USA
| | - Yair Rivenson
- Electrical Engineering Department, University of California, Los Angeles, Los Angeles, CA 90095, USA
- Bioengineering Department, University of California, Los Angeles, Los Angeles, CA 90095, USA
- California NanoSystems Institute, University of California, Los Angeles, Los Angeles, CA 90095, USA
| | - Rajan P. Kulkarni
- Bioengineering Department, University of California, Los Angeles, Los Angeles, CA 90095, USA
- California NanoSystems Institute, University of California, Los Angeles, Los Angeles, CA 90095, USA
- Division of Dermatology, Department of Medicine, David Geffen School of Medicine, University of California, Los Angeles, Los Angeles, CA 90095 USA
- Jonsson Comprehensive Cancer Center, University of California, Los Angeles, Los Angeles, CA 90095, USA
| | - Aydogan Ozcan
- Electrical Engineering Department, University of California, Los Angeles, Los Angeles, CA 90095, USA
- Bioengineering Department, University of California, Los Angeles, Los Angeles, CA 90095, USA
- California NanoSystems Institute, University of California, Los Angeles, Los Angeles, CA 90095, USA
- Department of Surgery, David Geffen School of Medicine, University of California, Los Angeles, Los Angeles, CA 90095, USA
| |
Collapse
|
16
|
Somkuwar AS, Das B, Vinu RV, Park Y, Singh RK. Holographic imaging through a scattering layer using speckle interferometry. J Opt Soc Am A Opt Image Sci Vis 2017; 34:1392-1399. [PMID: 29036106 DOI: 10.1364/josaa.34.001392] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [What about the content of this article? (0)] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 04/03/2017] [Accepted: 06/30/2017] [Indexed: 06/07/2023]
Abstract
Optical imaging through complex scattering media is one of the major technical challenges with important applications in many research fields, ranging from biomedical imaging to astronomical telescopy to spatially multiplexed optical communications. Various approaches for imaging through a turbid layer have been recently proposed that exploit the advantage of object information encoded in correlations of the random optical fields. Here we propose and experimentally demonstrate an alternative approach for single-shot imaging of objects hidden behind an opaque scattering layer. The proposed technique relies on retrieving the interference fringes projected behind the scattering medium, which leads to complex field reconstruction, from far-field laser speckle interferometry with two-point intensity correlation measurement. We demonstrate that under suitable conditions, it is possible to perform imaging to reconstruct the complex amplitude of objects situated at different depths.
Collapse
|
17
|
Park G, Han D, Kim G, Shin S, Kim K, Park JK, Park Y. Visualization and label-free quantification of microfluidic mixing using quantitative phase imaging. Appl Opt 2017; 56:6341-6347. [PMID: 29047833 DOI: 10.1364/ao.56.006341] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [What about the content of this article? (0)] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/15/2023]
Abstract
Microfluidic mixing plays a key role in various fields, including biomedicine and chemical engineering. To date, although various approaches for imaging microfluidic mixing have been proposed, they provide only quantitative imaging capability and require exogenous labeling agents. Quantitative phase imaging techniques, however, circumvent these problems and offer label-free quantitative information about concentration maps of microfluidic mixing. We present the quantitative phase imaging of microfluidic mixing in various types of polydimethylsiloxane microfluidic channels with different geometries; the feasibility of the present method was validated by comparing it with the results obtained by theoretical calculation based on Fick's law.
Collapse
|
18
|
Yeom E, Kim HM, Park JH, Choi W, Doh J, Lee SJ. Microfluidic system for monitoring temporal variations of hemorheological properties and platelet adhesion in LPS-injected rats. Sci Rep 2017; 7:1801. [PMID: 28496179 DOI: 10.1038/s41598-017-01985-w] [Citation(s) in RCA: 25] [Impact Index Per Article: 3.6] [Reference Citation Analysis] [What about the content of this article? (0)] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/26/2016] [Accepted: 04/05/2017] [Indexed: 12/21/2022] Open
Abstract
Sepsis causes multiple organs failures and eventually death. Changes in blood constituents due to sepsis lead to alterations in hemorheological properties, and cell adhesiveness. In this study, a new microfluidic system is proposed to measure temporal variations in biophysical properties of blood after injecting lipopolysaccharide (LPS) into a rat extracorporeal model under ex vivo condition. To measure blood viscosity, the interfacial line between blood and a reference fluid is formed in a Y-shaped channel. Based on the relation between interfacial width and pressure ratio, the temporal variation in blood viscosity is estimated. Optical images of blood flows are analyzed by decreasing flow rate for examination of red blood cell (RBC) aggregation. Platelets initiated by shear acceleration around the stenosis adhere to the post-stenosed region. By applying a correlation map that visualizes the decorrelation of the streaming blood flow, the area of adhered platelets can be quantitatively attained without labeling of platelets. To assess sepsis inflammation, conventional biomarkers (PCT and IL-8) are also monitored. The increasing tendency for blood viscosity, RBC aggregation, platelet adhesion, and septic biomarkers are observed after LPS injection. This microfluidic system would be beneficial for monitoring the changes in hemorheological properties and platelet activation caused by sepsis.
Collapse
|
19
|
Brand AS. Phase Uncertainty in Digital Holographic Microscopy Measurements in the Presence of Solution Flow Conditions. J Res Natl Inst Stand Technol 2017; 122:1-41. [PMID: 34877088 PMCID: PMC7339615 DOI: 10.6028/jres.122.022] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Accepted: 03/20/2017] [Indexed: 06/07/2023]
Abstract
Digital holographic microscopy (DHM) is a surface topography measurement technique with reported sub-nanometer vertical resolution. Although it has been made commercially available recently, few studies have evaluated the uncertainty or noise in the phase measurement by the DHM. As current research is using the DHM to monitor surface topography changes of dissolving materials under flowing water conditions, it is necessary to evaluate the effect of water and flow rate on the uncertainty in the measurement. Uncertainty in this study was concerned with the temporal standard deviation per pixel of the reconstructed phase. Considering the effects of solution flow rate, magnification, objective lens type (air or immersion), and experimental configuration, measurements under static conditions in air and in water with an immersion lens yielded the smallest amount of uncertainty (mean of ≤ 0.5 nm up to 40× magnification). Increasing the water flow rate resulted in an increase in mean uncertainty to ≤ 0.6 nm up to 40× with an immersion lens. Observations of a sample through a glass window at 20× magnification in flowing water also yielded increasing uncertainty, with mean values of ≤ 0.5 nm, ≤ 0.8 nm, and ≤ 1.1 nm for flow rates of 0 mL min-1, 15 mL min-1, and 33 mL min-1. Different hologram acquisition rates (12.5 s-1 and 25 s-1) did not significantly impact the uncertainty in the phase. Collecting holograms in single-wavelength versus dual-wavelength modes did impact the uncertainty, with the mean uncertainty at 10× magnification for the same wavelength being ≤ 0.5 nm from the single-wavelength mode compared to ≤ 1.5 nm from the dual-wavelength mode. When the quantified uncertainty was applied to simulated dissolution data, lower limits of measured dissolution rates were found below which the measured data may not be distinguishable from the uncertainty in the measurement. The limiting surface-normal dissolution velocity is -10-11.7 m s-1 for experiments with an immersion lens in flowing water conditions and -10-11.7 m s-1, -10-11.4 m s-1, and -10-11.0 m s-1 for static (0 mL min-1), slow (≤ 15 mL min-1), and fast (≤ 109 mL min-1) flowing water conditions in experiments with a glass window, respectively. The data presented by this study will allow for better experimental design and methodology for future dissolution or precipitation studies using DHM and will provide confidence in the data produced in postprocessing.
Collapse
Affiliation(s)
- Alexander S Brand
- National Institute of Standards and Technology, Gaithersburg, MD 20899, USA
| |
Collapse
|
20
|
Singh AK, Naik DN, Pedrini G, Takeda M, Osten W. Exploiting scattering media for exploring 3D objects. Light Sci Appl 2017; 6:e16219. [PMID: 30167232 PMCID: PMC6062180 DOI: 10.1038/lsa.2016.219] [Citation(s) in RCA: 15] [Impact Index Per Article: 2.1] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 05/02/2016] [Revised: 08/22/2016] [Accepted: 09/04/2016] [Indexed: 05/20/2023]
Abstract
Scattering media, such as diffused glass and biological tissue, are usually treated as obstacles in imaging. To cope with the random phase introduced by a turbid medium, most existing imaging techniques recourse to either phase compensation by optical means or phase recovery using iterative algorithms, and their applications are often limited to two-dimensional imaging. In contrast, we utilize the scattering medium as an unconventional imaging lens and exploit its lens-like properties for lensless three-dimensional (3D) imaging with diffraction-limited resolution. Our spatially incoherent lensless imaging technique is simple and capable of variable focusing with adjustable depths of focus that enables depth sensing of 3D objects that are concealed by the diffusing medium. Wide-field imaging with diffraction-limited resolution is verified experimentally by a single-shot recording of the 1951 USAF resolution test chart, and 3D imaging and depth sensing are demonstrated by shifting focus over axially separated objects.
Collapse
Affiliation(s)
- Alok Kumar Singh
- Institut für Technische Optik (ITO) and Stuttgart Research Center of Photonic Engineering (SCoPE), University of Stuttgart, Pfaffenwaldring 9, 70569 Stuttgart, Germany
| | - Dinesh N Naik
- Institut für Technische Optik (ITO) and Stuttgart Research Center of Photonic Engineering (SCoPE), University of Stuttgart, Pfaffenwaldring 9, 70569 Stuttgart, Germany
- School of Physics, University of Hyderabad, Hyderabad 500 046, India
| | - Giancarlo Pedrini
- Institut für Technische Optik (ITO) and Stuttgart Research Center of Photonic Engineering (SCoPE), University of Stuttgart, Pfaffenwaldring 9, 70569 Stuttgart, Germany
| | - Mitsuo Takeda
- Institut für Technische Optik (ITO) and Stuttgart Research Center of Photonic Engineering (SCoPE), University of Stuttgart, Pfaffenwaldring 9, 70569 Stuttgart, Germany
- Center for Optical Research and Education (CORE), Utsunomiya University, Yoto 7-1-2, Utsunomiya, Tochigi, 321- 8585, Japan
| | - Wolfgang Osten
- Institut für Technische Optik (ITO) and Stuttgart Research Center of Photonic Engineering (SCoPE), University of Stuttgart, Pfaffenwaldring 9, 70569 Stuttgart, Germany
| |
Collapse
|
21
|
Cho M, Javidi B. Peplography-a passive 3D photon counting imaging through scattering media. Opt Lett 2016; 41:5401-5404. [PMID: 27842142 DOI: 10.1364/ol.41.005401] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/06/2023]
Abstract
Dynamic imaging through scattering media under natural light is a significant challenge in many applications. To overcome this challenge, we propose a new passive imaging technique in scattering media using statistical estimation and photon counting modeling. We directly detect the ballistic photons from objects in scattering media based on statistical optics and then show experimental results to support our proposed method. We have named the proposed technique "peplography." The word comes from Greek words πε'πλo (péplo; "veiled") and γραϕη'ς (grafís; "writing"). The peplography system directly detects ballistic photons associated with the objects from a single peplogram ("veiled image") based on statistical optics, and reconstructs the three-dimensional (3D) peplogram using integral imaging.
Collapse
|
22
|
Yeom E, Lee SJ. Microfluidic-based speckle analysis for sensitive measurement of erythrocyte aggregation: A comparison of four methods for detection of elevated erythrocyte aggregation in diabetic rat blood. Biomicrofluidics 2015; 9:024110. [PMID: 25945136 PMCID: PMC4385097 DOI: 10.1063/1.4917023] [Citation(s) in RCA: 33] [Impact Index Per Article: 3.7] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 02/24/2015] [Accepted: 03/26/2015] [Indexed: 05/15/2023]
Abstract
Biochemical alterations in the plasma and red blood cell (RBC) membrane of diabetic blood lead to excessive erythrocyte aggregation (EA). EA would significantly impede the blood flow and increase the vascular flow resistance contributing to peripheral vascular diseases. In this study, a simple microfluidic-based method is proposed to achieve sensitive detection of hyperaggregation. When a blood sample is delivered into the device, images of blood flows are obtained with a short exposure time for a relatively long measuring time. A micro-particle image velocimetry technique was employed to monitor variation of the flow rate of blood as a function of time. Given that EA formation in the channel creates clear speckle patterns, the EA extent can be estimated by calculating a speckle area (ASpeckle) through a normalized autocovariance function. The hematocrit effect is assessed by comparing optical images transmitted through blood samples. EA variations caused by dextran treatment are quantitatively evaluated using characteristic time (λSpeckle) obtained by fitting the variations of ASpeckle. Other indices including number of RBCs in an aggregate (NRBC), characteristic time of erythrocyte sedimentation rate (λESR), and aggregation index estimated from ultrasound signals (AIEcho) are determined under different EA conditions using conventional techniques. The four different methods are applied to diabetic blood samples to compare their indices under hyperaggregation conditions. It is found that the proposed method can detect variation of EA reasonably, compared with conventional measurement techniques. These experimental demonstrations support the notion that the proposed method is capable of effectively monitoring the biophysical properties of diabetic blood.
Collapse
Affiliation(s)
- Eunseop Yeom
- Department of Mechanical Engineering, Pohang University of Science and Technology (POSTECH) , Pohang, South Korea
| | - Sang Joon Lee
- Department of Mechanical Engineering, Pohang University of Science and Technology (POSTECH) , Pohang, South Korea
| |
Collapse
|
23
|
Majeed H, Kandel ME, Han K, Luo Z, Macias V, Tangella K, Balla A, Popescu G. Breast cancer diagnosis using spatial light interference microscopy. J Biomed Opt 2015; 20:111210. [PMID: 26291148 DOI: 10.1117/1.jbo.20.11.111210] [Citation(s) in RCA: 19] [Impact Index Per Article: 2.1] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 03/15/2015] [Accepted: 07/17/2015] [Indexed: 05/20/2023]
Abstract
The standard practice in histopathology of breast cancers is to examine a hematoxylin and eosin (H&E) stained tissue biopsy under a microscope to diagnose whether a lesion is benign or malignant. This determination is made based on a manual, qualitative inspection, making it subject to investigator bias and resulting in low throughput. Hence, a quantitative, label-free, and high-throughput diagnosis method is highly desirable. We present here preliminary results showing the potential of quantitative phase imaging for breast cancer screening and help with differential diagnosis. We generated phase maps of unstained breast tissue biopsies using spatial light interference microscopy (SLIM). As a first step toward quantitative diagnosis based on SLIM, we carried out a qualitative evaluation of our label-free images. These images were shown to two pathologists who classified each case as either benign or malignant. This diagnosis was then compared against the diagnosis of the two pathologists on corresponding H&E stained tissue images and the number of agreements were counted. The agreement between SLIM and H&E based diagnosis was 88% for the first pathologist and 87% for the second. Our results demonstrate the potential and promise of SLIM for quantitative, label-free, and high-throughput diagnosis.
Collapse
Affiliation(s)
- Hassaan Majeed
- University of Illinois at Urbana-Champaign, Department of Electrical and Computer Engineering, Beckman Institute of Advanced Science and Technology, Quantitative Light Imaging Laboratory, 405 North Mathews Avenue, Urbana, Illinois 61801, United States
| | - Mikhail E Kandel
- University of Illinois at Urbana-Champaign, Department of Electrical and Computer Engineering, Beckman Institute of Advanced Science and Technology, Quantitative Light Imaging Laboratory, 405 North Mathews Avenue, Urbana, Illinois 61801, United States
| | - Kevin Han
- University of Illinois at Urbana-Champaign, Department of Electrical and Computer Engineering, Beckman Institute of Advanced Science and Technology, Quantitative Light Imaging Laboratory, 405 North Mathews Avenue, Urbana, Illinois 61801, United States
| | - Zelun Luo
- University of Illinois at Urbana-Champaign, Department of Electrical and Computer Engineering, Beckman Institute of Advanced Science and Technology, Quantitative Light Imaging Laboratory, 405 North Mathews Avenue, Urbana, Illinois 61801, United States
| | - Virgilia Macias
- University of Illinois at Chicago, Department of Pathology, 840 South Wood Street, Suite 130 CSN, Chicago, Illinois 60612, United States
| | - Krishnarao Tangella
- University of Illinois at Urbana-Champaign, Christie Clinic and Department of Pathology, 1400 West Park Street, Urbana, Illinois 61801, United States
| | - Andre Balla
- University of Illinois at Chicago, Department of Pathology, 840 South Wood Street, Suite 130 CSN, Chicago, Illinois 60612, United States
| | - Gabriel Popescu
- University of Illinois at Urbana-Champaign, Department of Electrical and Computer Engineering, Beckman Institute of Advanced Science and Technology, Quantitative Light Imaging Laboratory, 405 North Mathews Avenue, Urbana, Illinois 61801, United States
| |
Collapse
|
24
|
Kollarova V, Collakova J, Dostal Z, Vesely P, Chmelik R. Quantitative phase imaging through scattering media by means of coherence-controlled holographic microscope. J Biomed Opt 2015; 20:111206. [PMID: 26244853 DOI: 10.1117/1.jbo.20.11.111206] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 03/13/2015] [Accepted: 07/01/2015] [Indexed: 06/04/2023]
Abstract
A coherence-controlled holographic microscope (CCHM) enables quantitative phase imaging with coherent as well as incoherent illumination. The low spatially coherent light induces a coherence gating effect, which makes observation of samples possible also through scattering media. The paper describes theoretically and simulates numerically imaging of a two-dimensional object through a static scattering layer by means of CCHM, with the main focus on the quantitative phase imaging quality. The authors have investigated both strongly and weakly scattering media characterized by different amounts of ballistic and diffuse light. It is demonstrated that the phase information can be revealed also for the case of the static, strongly scattering layer. The dependence of the quality of imaging process on the spatial light coherence is demonstrated. The theoretical calculations and numerical simulations are supported by experimental data gained with a model phase object, as well as living carcinoma cells treated in an optically turbid emulsion.
Collapse
Affiliation(s)
- Vera Kollarova
- Brno University of Technology, CEITEC-Central European Institute of Technology, Technicka 3058/10, Brno 616 00, Czech Republic
| | - Jana Collakova
- Brno University of Technology, CEITEC-Central European Institute of Technology, Technicka 3058/10, Brno 616 00, Czech RepublicbBrno University of Technology, Institute of Physical Engineering, Faculty of Mechanical Engineering, Technicka 2896/2, Brno 616
| | - Zbynek Dostal
- Brno University of Technology, CEITEC-Central European Institute of Technology, Technicka 3058/10, Brno 616 00, Czech RepublicbBrno University of Technology, Institute of Physical Engineering, Faculty of Mechanical Engineering, Technicka 2896/2, Brno 616
| | - Pavel Vesely
- Brno University of Technology, CEITEC-Central European Institute of Technology, Technicka 3058/10, Brno 616 00, Czech Republic
| | - Radim Chmelik
- Brno University of Technology, CEITEC-Central European Institute of Technology, Technicka 3058/10, Brno 616 00, Czech RepublicbBrno University of Technology, Institute of Physical Engineering, Faculty of Mechanical Engineering, Technicka 2896/2, Brno 616
| |
Collapse
|
25
|
Marquet P, Depeursinge C, Magistretti PJ. Review of quantitative phase-digital holographic microscopy: promising novel imaging technique to resolve neuronal network activity and identify cellular biomarkers of psychiatric disorders. Neurophotonics 2014; 1:020901. [PMID: 26157976 PMCID: PMC4478935 DOI: 10.1117/1.nph.1.2.020901] [Citation(s) in RCA: 82] [Impact Index Per Article: 8.2] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 05/20/2014] [Revised: 08/08/2014] [Accepted: 08/11/2014] [Indexed: 05/20/2023]
Abstract
Quantitative phase microscopy (QPM) has recently emerged as a new powerful quantitative imaging technique well suited to noninvasively explore a transparent specimen with a nanometric axial sensitivity. In this review, we expose the recent developments of quantitative phase-digital holographic microscopy (QP-DHM). Quantitative phase-digital holographic microscopy (QP-DHM) represents an important and efficient quantitative phase method to explore cell structure and dynamics. In a second part, the most relevant QPM applications in the field of cell biology are summarized. A particular emphasis is placed on the original biological information, which can be derived from the quantitative phase signal. In a third part, recent applications obtained, with QP-DHM in the field of cellular neuroscience, namely the possibility to optically resolve neuronal network activity and spine dynamics, are presented. Furthermore, potential applications of QPM related to psychiatry through the identification of new and original cell biomarkers that, when combined with a range of other biomarkers, could significantly contribute to the determination of high risk developmental trajectories for psychiatric disorders, are discussed.
Collapse
Affiliation(s)
- Pierre Marquet
- Centre Hospitalier Universitaire Vaudois (CHUV), Centre de Neurosciences Psychiatriques, Département de Psychiatrie, Site de Cery, Prilly/Lausanne CH-1008, Switzerland
- Brain Mind Institute, École Polytechnique Fédérale de Lausanne, Lausanne CH-1015, Switzerland
| | - Christian Depeursinge
- Brain Mind Institute, École Polytechnique Fédérale de Lausanne, Lausanne CH-1015, Switzerland
- King Abdullah University of Science and Technology (KAUST), Division of Biological and Environmental Sciences and Engineering, Thuwal 23955-6900, Kingdom of Saudi Arabia
| | - Pierre J. Magistretti
- Centre Hospitalier Universitaire Vaudois (CHUV), Centre de Neurosciences Psychiatriques, Département de Psychiatrie, Site de Cery, Prilly/Lausanne CH-1008, Switzerland
- Brain Mind Institute, École Polytechnique Fédérale de Lausanne, Lausanne CH-1015, Switzerland
- King Abdullah University of Science and Technology (KAUST), Division of Biological and Environmental Sciences and Engineering, Thuwal 23955-6900, Kingdom of Saudi Arabia
| |
Collapse
|
26
|
Memmolo P, Miccio L, Merola F, Gennari O, Netti PA, Ferraro P. 3D morphometry of red blood cells by digital holography. Cytometry A 2014; 85:1030-6. [PMID: 25242067 DOI: 10.1002/cyto.a.22570] [Citation(s) in RCA: 89] [Impact Index Per Article: 8.9] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/07/2014] [Revised: 06/24/2014] [Accepted: 08/29/2014] [Indexed: 12/23/2022]
Abstract
Three dimensional (3D) morphometric analysis of flowing and not-adherent cells is an important aspect for diagnostic purposes. However, diagnostics tools need to be quantitative, label-free and, as much as possible, accurate. Recently, a simple holographic approach, based on shape from silhouette algorithm, has been demonstrated for accurate calculation of cells biovolume and displaying their 3D shapes. Such approach has been adopted in combination with holographic optical tweezers and successfully applied to cells with convex shape. Nevertheless, unfortunately, the method fails in case of specimen with concave surfaces. Here, we propose an effective approach to achieve correct 3D shape measurement that can be extended in case of cells having concave surfaces, thus overcoming the limit of the previous technique. We prove the new procedure for healthy red blood cells (RBCs) (i.e., discocytes) having a concave surface in their central region. Comparative analysis of experimental results with a theoretical 3D geometrical model of RBC is discussed in order to evaluate accuracy of the proposed approach. Finally, we show that the method can be also useful to classify, in terms of morphology, different varieties of RBCs.
Collapse
Affiliation(s)
- Pasquale Memmolo
- Center for Advanced Biomaterials for Health Care@CRIB, Istituto Italiano di Tecnologia, Largo Barsanti e Matteucci 53, Napoli, 80125, Italy; CNR-Istituto Nazionale di Ottica, Via Campi Flegrei 34, Pozzuoli (NA), I-80078, Italy
| | | | | | | | | | | |
Collapse
|
27
|
Memmolo P, Paturzo M, Javidi B, Netti PA, Ferraro P. Refocusing criterion via sparsity measurements in digital holography. Opt Lett 2014; 39:4719-4722. [PMID: 25121857 DOI: 10.1364/ol.39.004719] [Citation(s) in RCA: 46] [Impact Index Per Article: 4.6] [Reference Citation Analysis] [What about the content of this article? (0)] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/03/2023]
Abstract
Several automatic approaches have been proposed in the past to compute the refocus distance in digital holography (DH). However most of them are based on a maximization or minimization of a suitable amplitude image contrast measure, regarded as a function of the reconstruction distance parameter. Here we show that, by using the sparsity measure coefficient regarded as a refocusing criterion in the holographic reconstruction, it is possible to recover the focus plane and, at the same time, establish the degree of sparsity of digital holograms, when samples of the diffraction Fresnel propagation integral are used as a sparse signal representation. We employ a sparsity measurement coefficient known as Gini's index thus showing for the first time, to the best of our knowledge, its application in DH, as an effective refocusing criterion. Demonstration is provided for different holographic configurations (i.e., lens and lensless apparatus) and for completely different objects (i.e., a thin pure phase microscopic object as an in vitro cell, and macroscopic puppets) preparation.
Collapse
|
28
|
Bianco V, Merola F, Miccio L, Memmolo P, Gennari O, Paturzo M, Netti PA, Ferraro P. Imaging adherent cells in the microfluidic channel hidden by flowing RBCs as occluding objects by a holographic method. Lab Chip 2014; 14:2499-504. [PMID: 24852283 DOI: 10.1039/c4lc00290c] [Citation(s) in RCA: 18] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/27/2023]
Abstract
Imaging through turbid media is a challenging topic. A liquid is considered turbid when dispersed particles provoke strong light scattering, thus destroying the image formation by any standard optical system. Generally, colloidal solutions belong to the class of turbid media since dispersed particles have dimensions ranging between 0.2 μm and 2 μm. However, in microfluidics, another relevant issue has to be considered in the case of flowing liquid made of a multitude of occluding objects, e.g. red blood cells (RBCs) flowing in veins. In such a case instead of severe scattering processes unpredictable phase delays occur resulting in a wavefront distortion, thus disturbing or even hindering the image formation of objects behind such obstructing layer. In fact RBCs can be considered to be thin transparent phase objects. Here we show that sharp amplitude imaging and phase-contrast mapping of cells hidden behind biological occluding objects, namely RBCs, is possible in harsh noise conditions and with a large field-of view by Multi-Look Digital Holography microscopy (ML-DH). Noteworthy, we demonstrate that ML-DH benefits from the presence of the RBCs, providing enhancement in terms of numerical resolution and noise suppression thus obtaining images whose quality is higher than the quality achievable in the case of a liquid without occlusive objects.
Collapse
Affiliation(s)
- Vittorio Bianco
- CNR-National Institute of Optics (INO), Via Campi Flegrei, 34, I-80078, Pozzuoli (NA), Italy.
| | | | | | | | | | | | | | | |
Collapse
|
29
|
Calabuig A, Matrecano M, Paturzo M, Ferraro P. Common-path configuration in total internal reflection digital holography microscopy. Opt Lett 2014; 39:2471-2474. [PMID: 24979021 DOI: 10.1364/ol.39.002471] [Citation(s) in RCA: 7] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [What about the content of this article? (0)] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/03/2023]
Abstract
Total Internal Reflection Digital Holographic Microscopy (TIRDHM) is recognized to be a powerful tool for retrieving quantitative phase images of cell-substrate interfaces, adhesions, and tissue structures close to the prism surface. In this Letter, we develop an improved TIRDHM system, taking advantage of a refractive index mismatch between the prism and the sample substrate, to allow phase-shifting DH with just a single-beam interferometric configuration. Instead of the traditional off-axis method, phase-shift method is used to retrieve amplitude and phase images in coherent light and TIR modality. Essentially, the substrate-prism interface acts like a beam splitter generating a reference beam, where the phase-shift dependence on the incident angle is exploited in this common-path configuration. With the aim to demonstrate the technique's validity, some experiments are performed to establish the advantage of this compact and simple configuration, in which the reference arm in the setup is avoided.
Collapse
|
30
|
Abstract
Imaging through turbid media using visible or IR light instead of harmful x ray is still a challenging problem, especially in dynamic imaging. A method of dynamic imaging through turbid media using digital holography is presented. In order to match the coherence length between the dynamic object wave and the reference wave, a cw laser is used. To solve the problem of difficult focusing in imaging through turbid media, an autofocus technology is applied. To further enhance the image contrast, a spatial filtering technique is used. A description of digital holography and experiments of imaging the objects hidden in turbid media are presented. The experimental result shows that dynamic images of the objects can be achieved by the use of digital holography.
Collapse
|
31
|
Navruz I, Coskun AF, Wong J, Mohammad S, Tseng D, Nagi R, Phillips S, Ozcan A. Smart-phone based computational microscopy using multi-frame contact imaging on a fiber-optic array. Lab Chip 2013; 13:4015-23. [PMID: 23939637 PMCID: PMC3804724 DOI: 10.1039/c3lc50589h] [Citation(s) in RCA: 50] [Impact Index Per Article: 4.5] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/19/2023]
Abstract
We demonstrate a cellphone based contact microscopy platform, termed Contact Scope, which can image highly dense or connected samples in transmission mode. Weighing approximately 76 grams, this portable and compact microscope is installed on the existing camera unit of a cellphone using an opto-mechanical add-on, where planar samples of interest are placed in contact with the top facet of a tapered fiber-optic array. This glass-based tapered fiber array has ~9 fold higher density of fiber optic cables on its top facet compared to the bottom one and is illuminated by an incoherent light source, e.g., a simple light-emitting-diode (LED). The transmitted light pattern through the object is then sampled by this array of fiber optic cables, delivering a transmission image of the sample onto the other side of the taper, with ~3× magnification in each direction. This magnified image of the object, located at the bottom facet of the fiber array, is then projected onto the CMOS image sensor of the cellphone using two lenses. While keeping the sample and the cellphone camera at a fixed position, the fiber-optic array is then manually rotated with discrete angular increments of e.g., 1-2 degrees. At each angular position of the fiber-optic array, contact images are captured using the cellphone camera, creating a sequence of transmission images for the same sample. These multi-frame images are digitally fused together based on a shift-and-add algorithm through a custom-developed Android application running on the smart-phone, providing the final microscopic image of the sample, visualized through the screen of the phone. This final computation step improves the resolution and also removes spatial artefacts that arise due to non-uniform sampling of the transmission intensity at the fiber optic array surface. We validated the performance of this cellphone based Contact Scope by imaging resolution test charts and blood smears.
Collapse
Affiliation(s)
- Isa Navruz
- Electrical Engineering Department, University of California, Los Angeles, CA 90095, USA.
| | | | | | | | | | | | | | | |
Collapse
|
32
|
Bianco V, Paturzo M, Gennari O, Finizio A, Ferraro P. Imaging through scattering microfluidic channels by digital holography for information recovery in lab on chip. Opt Express 2013; 21:23985-23996. [PMID: 24104309 DOI: 10.1364/oe.21.023985] [Citation(s) in RCA: 9] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [What about the content of this article? (0)] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/02/2023]
Abstract
We tackle the problem of information recovery and imaging through scattering microfluidic chips by means of digital holography (DH). In many cases the chip can become opalescent due to residual deposits settling down the inner channel faces, biofilm formation, scattering particle uptake by the channel cladding or its damaging by corrosive substances, or even by condensing effect on the exterior channels walls. In these cases white-light imaging is severely degraded and no information is obtainable at all about the flowing samples. Here we investigate the problem of counting and estimating velocity of cells flowing inside a scattering chip. Moreover we propose and test a method based on the recording of multiple digital holograms to retrieve improved phase-contrast images despite the strong scattering effect. This method helps, thanks to DH, to recover information which, otherwise, would be completely lost.
Collapse
|
33
|
Abstract
We present a method, intensity fluctuation modulation (IFM), to obtain a full-field laser speckle microvessel image. Different from laser speckle contrast analysis, IFM imaging is insensitive to flow velocity and can be used to reconstruct microvessel images with higher spatial resolution and SNR. An in vivo animal experiment on a mouse pinna is conducted to demonstrate that IFM imaging is capable of achieving laser speckle microangiography.
Collapse
Affiliation(s)
- Yaguang Zeng
- Department of Physics and Applied Optics Beijing Area Major Laboratory, Beijing Normal University, Beijing 100875, China
| | | | | | | | | |
Collapse
|
34
|
Abstract
In this Letter we propose a method to enhance the limited depth of field (DOF) in optical imaging systems, through digital holography. The proposed approach is based on the introduction of a cubic phase plate into the diffraction integral, analogous to what occurs in white-light imaging systems. By this approach we show that it is possible to improve the DOF and to recover the extended focus image of a tilted object in a single reconstruction step. Moreover, we demonstrate the possibility of obtaining well-focused biological cells flowing into a tilted microfluidic channel.
Collapse
|
35
|
Locatelli M, Pugliese E, Paturzo M, Bianco V, Finizio A, Pelagotti A, Poggi P, Miccio L, Meucci R, Ferraro P. Imaging live humans through smoke and flames using far-infrared digital holography. Opt Express 2013; 21:5379-5390. [PMID: 23482109 DOI: 10.1364/oe.21.005379] [Citation(s) in RCA: 13] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/01/2023]
Abstract
The ability to see behind flames is a key challenge for the industrial field and particularly for the safety field. Development of new technologies to detect live people through smoke and flames in fire scenes is an extremely desirable goal since it can save human lives. The latest technologies, including equipment adopted by fire departments, use infrared bolometers for infrared digital cameras that allow users to see through smoke. However, such detectors are blinded by flame-emitted radiation. Here we show a completely different approach that makes use of lensless digital holography technology in the infrared range for successful imaging through smoke and flames. Notably, we demonstrate that digital holography with a cw laser allows the recording of dynamic human-size targets. In this work, easy detection of live, moving people is achieved through both smoke and flames, thus demonstrating the capability of digital holography at 10.6 μm.
Collapse
Affiliation(s)
- M Locatelli
- CNR Istituto Nazionale di Ottica-Largo E Fermi, 6 50125 Firenze, Italy
| | | | | | | | | | | | | | | | | | | |
Collapse
|
36
|
Memmolo P, Iannone M, Ventre M, Netti PA, Finizio A, Paturzo M, Ferraro P. Quantitative phase maps denoising of long holographic sequences by using SPADEDH algorithm. Appl Opt 2013; 52:1453-1460. [PMID: 23458798 DOI: 10.1364/ao.52.001453] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 10/12/2012] [Accepted: 01/29/2013] [Indexed: 06/01/2023]
Abstract
We propose a denoising method for digital holography mod 2π wrapped phase map by using an adaptation of the SPArsity DEnoising of Digital Holograms (SPADEDH) algorithm. SPADEDH is a l(1) minimization algorithm able to suppress the noise components on digital holograms without any prior knowledge or estimation about the statistics of noise. We test our algorithm with either general numerical simulated wrapped phase, quantifying the performance with different efficiency parameters and comparing it with two popular denoising strategies, i.e., median and Gaussian filters, and specific experimental tests, by focusing our attention on long-sequence wrapped quantitative phase maps (QPMs) of in vitro cells, which aim to have uncorrupted QPMs. In addition, we prove that the proposed algorithm can be used as a helper for the typical local phase unwrapping algorithms.
Collapse
Affiliation(s)
- Pasquale Memmolo
- Center for Advanced Biomaterials for Health Care@CRIB, Istituto Italiano di Tecnologia, Napoli, Italy.
| | | | | | | | | | | | | |
Collapse
|
37
|
Bianco V, Paturzo M, Finizio A, Balduzzi D, Puglisi R, Galli A, Ferraro P. Clear coherent imaging in turbid microfluidics by multiple holographic acquisitions. Opt Lett 2012; 37:4212-4214. [PMID: 23073414 DOI: 10.1364/ol.37.004212] [Citation(s) in RCA: 9] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/01/2023]
Abstract
Recently it has been demonstrated that digital holography is a powerful means allowing imaging of both amplitude and phase objects in turbid flowing media. However, in quasi-static turbid microfluidics, multiple scattering contributions through the colloids superimpose coherently to the recording device, resulting in speckle noise and hindering a clear vision of the objects. In this Letter we exploit the Brownian motion of the colloidal particles to get multiple uncorrelated holograms, and we combine them to reduce the speckle contrast. In this way we get a multi-look gain without losing image resolution.
Collapse
Affiliation(s)
- Vittorio Bianco
- CNR—National Institute of Optics, Via Campi Flegrei, 34, Pozzuoli (NA) I-80078, Italy.
| | | | | | | | | | | | | |
Collapse
|