Soliveri L, Bruneau D, Ring J, Bozzetto M, Remuzzi A, Valen-Sendstad K. Toward a physiological model of vascular wall vibrations in the arteriovenous fistula. Biomech Model Mechanobiol 2024:10.1007/s10237-024-01865-z. [PMID: 38977647 DOI: 10.1007/s10237-024-01865-z] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/09/2023] [Accepted: 06/05/2024] [Indexed: 07/10/2024]
Abstract
The mechanism behind hemodialysis arteriovenous fistula (AVF) failure remains poorly understood, despite previous efforts to correlate altered hemodynamics with vascular remodeling. We have recently demonstrated that transitional flow induces high-frequency vibrations in the AVF wall, albeit with a simplified model. This study addresses the key limitations of our original fluid-structure interaction (FSI) approach, aiming to evaluate the vibration response using a more realistic model. A 3D AVF geometry was generated from contrast-free MRI and high-fidelity FSI simulations were performed. Patient-specific inflow and pressure were incorporated, and a three-term Mooney-Rivlin model was fitted using experimental data. The viscoelastic effect of perivascular tissue was modeled with Robin boundary conditions. Prescribing pulsatile inflow and pressure resulted in a substantial increase in vein displacement ( + 400 %) and strain ( + 317 %), with a higher maximum spectral frequency becoming visible above -42 dB (from 200 to 500 Hz). Transitioning from Saint Venant-Kirchhoff to Mooney-Rivlin model led to displacement amplitudes exceeding 10 micrometers and had a substantial impact on strain ( + 116 %). Robin boundary conditions significantly damped high-frequency displacement ( - 60 %). Incorporating venous tissue properties increased vibrations by 91%, extending up to 700 Hz, with a maximum strain of 0.158. Notably, our results show localized, high levels of vibration at the inner curvature of the vein, a site known for experiencing pronounced remodeling. Our findings, consistent with experimental and clinical reports of bruits and thrills, underscore the significance of incorporating physiologically plausible modeling approaches to investigate the role of wall vibrations in AVF remodeling and failure.
Collapse
Affiliation(s)
- Luca Soliveri
- Department of Bioengineering, Istituto di Ricerche Farmacologiche Mario Negri IRCCS, Bergamo, Italy
| | - David Bruneau
- Department of Mechanical and Industrial Engineering, University of Toronto, Toronto, Canada
| | - Johannes Ring
- Department of Computational Physiology, Simula Research Laboratory, Oslo, Norway
| | - Michela Bozzetto
- Department of Bioengineering, Istituto di Ricerche Farmacologiche Mario Negri IRCCS, Bergamo, Italy
| | - Andrea Remuzzi
- Department of Management, Information and Production Engineering, University of Bergamo, Bergamo, Italy
| | | |
Collapse
|
2
|
Lei D, Lei J, Xu H. Biomechanical characteristics of arteries during pelvic fracture reduction and dynamic simulation analysis. Comput Methods Biomech Biomed Engin 2024:1-14. [PMID: 38439667 DOI: 10.1080/10255842.2024.2324880] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/07/2023] [Accepted: 02/24/2024] [Indexed: 03/06/2024]
Abstract
During robot-assisted reduction of pelvic fracture, blood vessels are susceptible to tensile and shear forces, making them prone to injury. Considering the impact of pelvic reduction on the risk of arterial injury, the biomechanical characteristics of arteries during the pelvic fracture reduction process are studied, and a refined coupled composite model of the damaged pelvic structure is established. Dynamic simulations of pelvic fracture reduction are conducted based on the planned reduction path. The simulation results show that during the reduction process, when the affected side is rotated, the stress and strain of the artery are maximum, particularly at the locations of the iliac common artery, internal iliac artery, and the superior gluteal artery arch endure significant stress and strain. After reduction, the maximum stress is observed in the right superior gluteal artery, and the maximum strain occurs at the intersection of the right iliac common artery. The stretch ratio of both the left and right iliac common arteries is considerable. Therefore, it can be concluded that the superior gluteal artery and the internal iliac artery are prone to injury, particularly the segment from the origin of the superior gluteal artery to its passage around the greater sciatic notch. After reduction, substantial traction on the iliac common artery, which makes it more susceptible to deformation, carries a risk of arterial rupture and aneurysm formation. This study provides a reference for planning the safe reduction path of pelvic fracture surgery and improving safety.
Collapse
Affiliation(s)
- Dongwei Lei
- School of Mechatronic Engineering and Automation, Shanghai University, Shanghai, China
| | - Jingtao Lei
- School of Mechatronic Engineering and Automation, Shanghai University, Shanghai, China
| | - Haifei Xu
- School of Mechatronic Engineering and Automation, Shanghai University, Shanghai, China
| |
Collapse
|
3
|
Bhave A, Sittkus B, Urban G, Mescheder U, Möller K. Finite element analysis of the interaction between high-compliant balloon catheters and non-cylindrical vessel structures: towards tactile sensing balloon catheters. Biomech Model Mechanobiol 2023; 22:2033-2061. [PMID: 37573552 PMCID: PMC10613175 DOI: 10.1007/s10237-023-01749-8] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/13/2022] [Accepted: 07/06/2023] [Indexed: 08/15/2023]
Abstract
Aiming for sensing balloon catheters which are able to provide intraoperative information of the vessel stiffness and shape, the present study uses finite element analysis (FEA) to evaluate the interaction between high-compliant elastomer balloon catheters with the inner wall of a non-cylindrical-shaped lumen structure. The contact simulations are based on 3D models with varying balloon thicknesses and varying tissue geometries to analyse the resulting balloon and tissue deformation as well as the inflation pressure dependent contact area. The wrinkled tissue structure is modelled by utilizing a two-layer fibre-based Holzapfel-Gasser-Ogden constitutive model and the model parameters are adapted based on available biomechanical data for human urethral vessel samples. The balloon catheter structure is implemented as a high-compliant hyper-elastic silicone material (based on polydimethylsiloxane (PDMS)) with a varying catheter wall thickness between 0.5 and 2.5 µm. Two control parameters are introduced to describe the balloon shape adaption in reaction to a wrinkled vessel wall during the inflation process. Basic semi-quantitative relations are revealed depending on the evolving balloon deformation and contact surface. Based on these relations some general design guidelines for balloon-based sensor catheters are presented. The results of the conducted in-silico study reveal some general interdependencies with respect to the compliance ratio between balloon and tissue and also in respect of the tissue aspect ratio. Further they support the proposed concept of high-compliant balloon catheters equipped for tactile sensing as diagnosis approach in urology and angioplasty.
Collapse
Affiliation(s)
- Ashish Bhave
- Institute of Technical Medicine (ITeM), Furtwangen University, 78054, Villingen-Schwenningen, Germany
- Department of Microsystems Engineering, IMTEK, University of Freiburg, 79110, Freiburg, Germany
| | - Benjamin Sittkus
- Department of Microsystems Engineering, IMTEK, University of Freiburg, 79110, Freiburg, Germany.
- Institute for Microsystems Technology (iMST), Furtwangen University, 78120, Furtwangen, Germany.
| | - Gerald Urban
- Department of Microsystems Engineering, IMTEK, University of Freiburg, 79110, Freiburg, Germany
| | - Ulrich Mescheder
- Institute for Microsystems Technology (iMST), Furtwangen University, 78120, Furtwangen, Germany
- Associated to the Faculty of Engineering, University of Freiburg, 79110, Freiburg, Germany
| | - Knut Möller
- Institute of Technical Medicine (ITeM), Furtwangen University, 78054, Villingen-Schwenningen, Germany
- Associated to the Faculty of Engineering, University of Freiburg, 79110, Freiburg, Germany
- Department of Mechanical Engineering, University of Canterbury, Christchurch, New Zealand
| |
Collapse
|
4
|
Stratakos E, Antonini L, Poletti G, Berti F, Tzafriri AR, Petrini L, Pennati G. Investigating Balloon-Vessel Contact Pressure Patterns in Angioplasty: In Silico Insights for Drug-Coated Balloons. Ann Biomed Eng 2023; 51:2908-2922. [PMID: 37751027 PMCID: PMC10632265 DOI: 10.1007/s10439-023-03359-y] [Citation(s) in RCA: 3] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/23/2023] [Accepted: 09/02/2023] [Indexed: 09/27/2023]
Abstract
Drug-Coated Balloons have shown promising results as a minimally invasive approach to treat stenotic arteries, but recent animal studies have revealed limited, non-uniform coating transfer onto the arterial lumen. In vitro data suggested that local coating transfer tracks the local Contact Pressure (CP) between the balloon and the endothelium. Therefore, this work aimed to investigate in silico how different interventional and device parameters may affect the spatial distribution of CP during the inflation of an angioplasty balloon within idealized vessels that resemble healthy femoral arteries in size and compliance. An angioplasty balloon computational model was developed, considering longitudinal non-uniform wall thickness, due to its forming process, and the folding procedure of the balloon. To identify the conditions leading to non-uniform CP, sensitivity finite element analyses were performed comparing different values for balloon working length, longitudinally varying wall thickness, friction coefficient on the balloon-vessel interface, vessel wall stiffness and thickness, and balloon-to-vessel diameter ratio. Findings indicate a significant irregularity of contact between the balloon and the vessel, mainly affected by the balloon's unfolding and longitudinal thickness variation. Mirroring published data on coating transfer distribution in animal studies, the interfacial CP distribution was maximal at the middle of the balloon treatment site, while exhibiting a circumferential pattern of linear peaks as a consequence of the particular balloon-vessel interaction during unfolding. A high ratio of balloon-to-vessel diameter, higher vessel stiffness, and thickness was found to increase significantly the amplitude and spatial distribution of the CP, while a higher friction coefficient at the balloon-to-vessel interface further exacerbated the non-uniformity of CP. Evaluation of balloon design effects revealed that the thicker tapered part caused CP reduction in the areas that interacted with the extremities of the balloon, whereas total length only weakly impacted the CP. Taken together, this study offers a deeper understanding of the factors influencing the irregularity of balloon-tissue contact, a key step toward uniformity in drug-coating transfer and potential clinical effectiveness.
Collapse
Affiliation(s)
- Efstathios Stratakos
- Laboratory of Biological Structure Mechanics, Department of Chemistry, Materials and Chemical Engineering "Giulio Natta", Politecnico di Milano, Milan, Italy
| | - Luca Antonini
- Laboratory of Biological Structure Mechanics, Department of Chemistry, Materials and Chemical Engineering "Giulio Natta", Politecnico di Milano, Milan, Italy
| | - Gianluca Poletti
- Laboratory of Biological Structure Mechanics, Department of Chemistry, Materials and Chemical Engineering "Giulio Natta", Politecnico di Milano, Milan, Italy
| | - Francesca Berti
- Laboratory of Biological Structure Mechanics, Department of Chemistry, Materials and Chemical Engineering "Giulio Natta", Politecnico di Milano, Milan, Italy
| | | | - Lorenza Petrini
- Department of Civil and Environmental Engineering, Politecnico di Milano, Milan, Italy.
| | - Giancarlo Pennati
- Laboratory of Biological Structure Mechanics, Department of Chemistry, Materials and Chemical Engineering "Giulio Natta", Politecnico di Milano, Milan, Italy
| |
Collapse
|
5
|
Multiscale agent-based modeling of restenosis after percutaneous transluminal angioplasty: Effects of tissue damage and hemodynamics on cellular activity. Comput Biol Med 2022; 147:105753. [DOI: 10.1016/j.compbiomed.2022.105753] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/14/2021] [Revised: 04/13/2022] [Accepted: 05/13/2022] [Indexed: 11/17/2022]
|
6
|
Bernini M, Colombo M, Dunlop C, Hellmuth R, Chiastra C, Ronan W, Vaughan TJ. Oversizing of self-expanding nitinol vascular stents – A biomechanical investigation in the superficial femoral artery. J Mech Behav Biomed Mater 2022; 132:105259. [DOI: 10.1016/j.jmbbm.2022.105259] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/17/2021] [Revised: 04/20/2022] [Accepted: 04/29/2022] [Indexed: 10/18/2022]
|
7
|
Characterizing the Mechanical Performance of a Bare-Metal Stent with an Auxetic Cell Geometry. APPLIED SCIENCES-BASEL 2022. [DOI: 10.3390/app12020910] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 01/08/2023]
Abstract
This study develops and characterizes the distinctive mechanical features of a stainless-steel metal stent with a tailored structure. A high-precision femtosecond laser was used to micromachine a stent with re-entrant hexagonal (auxetic) cell geometry. We then characterized its mechanical behavior under various mechanical loadings using in vitro experiments and through finite element analysis. The stent properties, such as the higher capability of the stent to bear upon bending, exceptional advantage at elevated levels of twisting angles, and proper buckling, all ensured a preserved opening to maintain the blood flow. The outcomes of this preliminary study present a potential design for a stent with improved physiologically relevant mechanical conditions such as longitudinal contraction, radial strength, and migration of the stent.
Collapse
|
8
|
Singh G, Chanda A. Mechanical properties of whole-body soft human tissues: a review. Biomed Mater 2021; 16. [PMID: 34587593 DOI: 10.1088/1748-605x/ac2b7a] [Citation(s) in RCA: 95] [Impact Index Per Article: 31.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/08/2021] [Accepted: 09/29/2021] [Indexed: 11/11/2022]
Abstract
The mechanical properties of soft tissues play a key role in studying human injuries and their mitigation strategies. While such properties are indispensable for computational modelling of biological systems, they serve as important references in loading and failure experiments, and also for the development of tissue simulants. To date, experimental studies have measured the mechanical properties of peripheral tissues (e.g. skin)in-vivoand limited internal tissuesex-vivoin cadavers (e.g. brain and the heart). The lack of knowledge on a majority of human tissues inhibit their study for applications ranging from surgical planning, ballistic testing, implantable medical device development, and the assessment of traumatic injuries. The purpose of this work is to overcome such challenges through an extensive review of the literature reporting the mechanical properties of whole-body soft tissues from head to toe. Specifically, the available linear mechanical properties of all human tissues were compiled. Non-linear biomechanical models were also introduced, and the soft human tissues characterized using such models were summarized. The literature gaps identified from this work will help future biomechanical studies on soft human tissue characterization and the development of accurate medical models for the study and mitigation of injuries.
Collapse
Affiliation(s)
- Gurpreet Singh
- Centre for Biomedical Engineering, Indian Institute of Technology (IIT), Delhi, India
| | - Arnab Chanda
- Centre for Biomedical Engineering, Indian Institute of Technology (IIT), Delhi, India.,Department of Biomedical Engineering, All India Institute of Medical Sciences (AIIMS), Delhi, India
| |
Collapse
|
9
|
Wiesent L, Spear A, Nonn A. Computational analysis of the effects of geometric irregularities on the interaction of an additively manufactured 316L stainless steel stent and a coronary artery. J Mech Behav Biomed Mater 2021; 125:104878. [PMID: 34655944 DOI: 10.1016/j.jmbbm.2021.104878] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/02/2021] [Revised: 09/24/2021] [Accepted: 09/30/2021] [Indexed: 10/20/2022]
Abstract
Customized additively manufactured (laser powder bed fused (L-PBF)) stents could improve the treatment of complex lesions by enhancing stent-artery conformity. However, geometric irregularities inherent for L-PBF stents are expected to influence not only their mechanical behavior but also their interaction with the artery. In this study, the influence of geometrical irregularities on stent-artery interaction is evaluated within a numerical framework. Thus, computed arterial stresses induced by a reconstructed L-PBF stent model are compared to those induced by the intended stent model (also representing a stent geometry obtained from conventional manufacturing processes) and a modified CAD stent model that accounts for the increased strut thickness inherent for L-PBF stents. It was found that, similar to conventionally manufactured stents, arterial stresses are initially related to the basic stent design/topology, with the highest stresses occurring at the indentations of the stent struts. Compared to the stent CAD model, the L-PBF stent induces distinctly higher and more maximum volume stresses within the plaque and the arterial wall. In return, the modified CAD model overestimates the arterial stresses induced by the L-PBF stent due to its homogeneously increased strut thickness and thus its homogeneously increased geometric stiffness compared with the L-PBF stent. Therefore, the L-PBF-induced geometric irregularities must be explicitly considered when evaluating the L-PBF stent-induced stresses because the intended stent CAD model underestimates the arterial stresses, whereas the modified CAD model overestimates them. The arterial stresses induced by the L-PBF stent were still within the range of values reported for conventional stents in literature, suggesting that the use of L-PBF stents is conceivable in principle. However, because geometric irregularities, such as protruding features from the stent surface, could potentially damage the artery or lead to premature stent failure, further improvement of L-PBF stents is essential.
Collapse
Affiliation(s)
- Lisa Wiesent
- Computational Mechanics and Materials Lab, Department of Mechanical Engineering, Ostbayerische Technische Hochschule (OTH) Regensburg, Regensburg, Germany; Technology Campus Neustadt a. d. Donau, Department of Mechanical Engineering, OTH Regensburg, Regensburg, Germany.
| | - Ashley Spear
- Department of Mechanical Engineering, University of Utah, Salt Lake City, UT, USA
| | - Aida Nonn
- Computational Mechanics and Materials Lab, Department of Mechanical Engineering, Ostbayerische Technische Hochschule (OTH) Regensburg, Regensburg, Germany; Technology Campus Neustadt a. d. Donau, Department of Mechanical Engineering, OTH Regensburg, Regensburg, Germany
| |
Collapse
|
10
|
Rahinj GB, Chauhan HS, Sirivella ML, Satyanarayana MV, Ramanan L. Numerical Analysis for Non-Uniformity of Balloon-Expandable Stent Deployment Driven by Dogboning and Foreshortening. Cardiovasc Eng Technol 2021; 13:247-264. [PMID: 34431035 DOI: 10.1007/s13239-021-00573-4] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 01/07/2021] [Accepted: 07/30/2021] [Indexed: 10/20/2022]
Abstract
PURPOSE Stenting is the most common intervention for arteriosclerosis treatment; however, the success of the treatment depends on the incidence of in-stent restenosis (ISR). Stent deployment characteristics are major influencers of ISR and can be measured in terms of dogboning, asymmetry, and foreshortening. This study aimed to analyse the implications of balloon and stent-catheter assembly parameters on the stent deployment characteristics. METHODS Experimental approach to analyse the impact of the balloon and stent-catheter assembly parameters on stent deployment characteristics is a time-consuming and complex task, whereas numerical methods prove to be quick, efficient, and reliable. In this study, eleven finite element models were employed to analyse non-uniform balloon stent expansion pattern, comprised of variation in, stent axial position on balloon, balloon length, balloon folding pattern, and balloon wall thickness. RESULTS Obtained results suggest that the axially noncentral position of the stent on balloon and variable balloon thickness lead to non-uniform stent deployment pattern. Also, it was proved that variation in balloon length and balloon folding pattern influence deployment process. CONCLUSION Improved positional accuracies, uniform balloon wall thickness, and selection of the appropriate length of a balloon for selected stent configuration will help to minimize dogboning, asymmetry, and foreshortening during non-uniform stent expansion, thereby reducing the risk of restenosis. The stated numerical approach will be helpful to optimize stent catheter assembly parameters thus minimizing in-vitro tests and product development time.
Collapse
Affiliation(s)
- Ganesh B Rahinj
- Research and Development Department, Sahajanand Medical Technologies (SMT) Ltd., Surat, India.
| | - Harshit S Chauhan
- Research and Development Department, Sahajanand Medical Technologies (SMT) Ltd., Surat, India
| | - Martin L Sirivella
- Research and Development Department, Sahajanand Medical Technologies (SMT) Ltd., Surat, India
| | - Menta V Satyanarayana
- Research and Development Department, Sahajanand Medical Technologies (SMT) Ltd., Surat, India
| | - Laxminarayanan Ramanan
- Research and Development Department, Sahajanand Medical Technologies (SMT) Ltd., Surat, India
| |
Collapse
|
11
|
Finite element analysis of cutting balloon expansion in a calcified artery model of circular angle 180°: Effects of balloon-to-diameter ratio and number of blades facing calcification on potential calcification fracturing and perforation reduction. PLoS One 2021; 16:e0251404. [PMID: 33984003 PMCID: PMC8118280 DOI: 10.1371/journal.pone.0251404] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/28/2020] [Accepted: 04/27/2021] [Indexed: 11/30/2022] Open
Abstract
Calcified artery lesions cause stent under-expansion and increase the risk of in-stent restenosis and stent thrombosis. Cutting balloons facilitate the fracturing of calcification prior to stent implantation, although vessel dissection and perforation are potential issues. In clinical practice, calcifications having maximum calcium angles ≤ 180° are rarely fractured during conventional balloon angioplasty. We hypothesize that the lesion/device diameter ratio and the number of blades facing a non-circular calcified lesion may be crucial for fracturing the calcification while avoiding vessel injury. The geometries of the cutting balloons were constructed and their finite-element models were generated by folding and wrapping the balloon model. Numerical simulations were performed for balloons with five different diameters and two types of blade directions in a 180° calcification model. The calcification expansion ability was distinctly higher when two blades faced the calcification than when one blade did. Moreover, when two blades faced the calcification model, larger maximum principal stresses were generated in the calcification even when using undersized balloons with diameters reduced by 0.25 or 0.5 mm from the reference diameter, when compared with the case where one blade faced the calcified model and a balloon of diameter equal to the reference diameter was used. When two blades faced the calcification, smaller stresses were generated in the artery adjacent to the calcification; further, the maximum stress generated in the artery model adjacent to the calcification under the rated pressure of 12 atm when employing undersized balloons was smaller than that when only one blade faced the calcification and when lesion-identical balloon diameters were used under a nominal pressure of 6 atm. Our study suggested that undersized balloons of diameters 0.25 or 0.5 mm less than the reference diameter might be effective in not only expanding the calcified lesion but also reducing the risk of dissection.
Collapse
|
12
|
On Structure-Function Relationships in the Female Human Urethra: A Finite Element Model Approach. Ann Biomed Eng 2021; 49:1848-1860. [PMID: 33782810 DOI: 10.1007/s10439-021-02765-4] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/20/2020] [Accepted: 03/02/2021] [Indexed: 10/21/2022]
Abstract
Remarkably little is known about urethral striated and smooth muscle and vascular plexus contributions to maintaining continence or initiating micturition. We therefore developed a 3-D, multiphysics, finite element model, based on sequential MR images from a 23-year-old nulliparous heathy woman, to examine the effect of contracting one or more individual muscle layers on the urethral closure pressure (UCP). The lofted urethra turned out to be both curved and asymmetric. The model results led us to reject the current hypothesis that the striated and smooth muscles contribute equally to UCP. While a simulated contraction of the outer (circular) striated muscle increased closure pressure, a similar contraction of the large inner longitudinal smooth muscle both reduced closure pressure and shortened urethral length, suggesting a role in initiating micturition. When age-related atrophy of the posterior striated muscle was simulated, a reduced and asymmetric UCP distribution developed in the transverse plane. Lastly, a simple 2D axisymmetric model of the vascular plexus and lumen suggests arteriovenous pressure plays and important role in helping to maintain luminal closure in the proximal urethra and thereby functional urethral length. More work is needed to examine interindividual differences and validate such models in vivo.
Collapse
|
13
|
García-Herrera CM, Cuevas ÁA, Celentano DJ, Navarrete Á, Aranda P, Herrera E, Uribe S. Analysis of the passive biomechanical behavior of a sheep-specific aortic artery in pulsatile flow conditions. Comput Methods Biomech Biomed Engin 2021; 24:1228-1241. [PMID: 33475015 DOI: 10.1080/10255842.2021.1872549] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/22/2022]
Abstract
In this work, a novel numerical-experimental procedure is proposed, through the use of the Cardiac Simulation Test (CST), device that allows the exposure of the arterial tissue to in-vitro conditions, mimicking cardiac cycles generated by the heart. The main goal is to describe mechanical response of the arterial wall under physiological conditions, when it is subjected to a variable pressure wave over time, which causes a stress state affecting the biomechanical behavior of the artery wall. In order to get information related to stress and strain states, numerical simulation via finite element method, is performed under a condition of systolic and diastolic pressure. The description of this methodological procedure is performed with a sample corresponding to a sheep aorta without cardiovascular pathologies. There are two major findings: the evaluation of the mechanical properties of the sheep aorta through the above-mentioned tests and, the numerical simulation of the mechanical response under the conditions present in the CST. The results state that differences between numerical and experimental circumferential stretch in diastole and systole to distinct zones studied do not exceed 1%. However, greater discrepancies can be seen in the distensibility and incremental modulus, two main indicators, which are in the order of 30%. In addition, numerical results determine an increase of the principal maximum stress and strain between the case of systolic and diastolic pressure, corresponding to 31.1% and 14.9% for the stress and strain measurement respectively; where maximum values of these variables are located in the zone of the ascending aorta and the aortic arch.
Collapse
Affiliation(s)
- Claudio M García-Herrera
- Departamento de Ingeniería Mecánica, Universidad de Santiago de Chile, Santiago, Chile.,ANID - Millennium Science Initiative Program - Millennium Nucleus in Cardiovascular Magnetic Resonance, Santiago, Chile
| | - Álvaro A Cuevas
- Departamento de Ingeniería Mecánica, Universidad de Santiago de Chile, Santiago, Chile
| | - Diego J Celentano
- Departamento de Ingeniería Mecánica y Metalúrgica, Pontificia Universidad Católica, Santiago, Chile.,Radiology department and biomedical imaging center, school of medicine, Pontificia Universidad Católica de Chile
| | - Álvaro Navarrete
- Departamento de Ingeniería Mecánica, Universidad de Santiago de Chile, Santiago, Chile
| | - Pedro Aranda
- Departamento de Ingeniería Mecánica, Universidad de Santiago de Chile, Santiago, Chile
| | - Emilio Herrera
- Programa de Fisiopatología, Facultad de Medicina, Instituto de Ciencias Biomédicas, Universidad de Chile, Santiago, Chile
| | - Sergio Uribe
- Radiology department and biomedical imaging center, school of medicine, Pontificia Universidad Católica de Chile.,ANID - Millennium Science Initiative Program - Millennium Nucleus in Cardiovascular Magnetic Resonance, Santiago, Chile
| |
Collapse
|
14
|
Zhu X, Umezu M, Iwasaki K. Finite Element Analysis of the Cutting Balloon With an Adequate Balloon-to-Artery Ratio for Fracturing Calcification While Preventing Perforation. Circ Rep 2021; 3:1-8. [PMID: 33693284 PMCID: PMC7939788 DOI: 10.1253/circrep.cr-20-0070] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/09/2022] Open
Affiliation(s)
- Xiaodong Zhu
- Department of Modern Mechanical Engineering, School of Creative Science and Engineering, Waseda University
| | - Mitsuo Umezu
- Department of Modern Mechanical Engineering, School of Creative Science and Engineering, Waseda University
- Department of Integrative Bioscience and Biomedical Engineering, Graduate School of Advanced Science and Engineering, Waseda University
- Cooperative Major in Advanced Biomedical Sciences, Graduate School of Advanced Science and Engineering, Waseda University
| | - Kiyotaka Iwasaki
- Department of Modern Mechanical Engineering, School of Creative Science and Engineering, Waseda University
- Department of Integrative Bioscience and Biomedical Engineering, Graduate School of Advanced Science and Engineering, Waseda University
- Cooperative Major in Advanced Biomedical Sciences, Graduate School of Advanced Science and Engineering, Waseda University
| |
Collapse
|
15
|
Rykowska I, Nowak I, Nowak R. Drug-Eluting Stents and Balloons-Materials, Structure Designs, and Coating Techniques: A Review. Molecules 2020; 25:E4624. [PMID: 33050663 PMCID: PMC7594099 DOI: 10.3390/molecules25204624] [Citation(s) in RCA: 33] [Impact Index Per Article: 8.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/09/2020] [Revised: 09/25/2020] [Accepted: 09/27/2020] [Indexed: 12/19/2022] Open
Abstract
Controlled drug delivery is a matter of interest to numerous scientists from various domains, as well as an essential issue for society as a whole. In the treatment of many diseases, it is crucial to control the dosing of a drug for a long time and thus maintain its optimal concentration in the tissue. Heart diseases are particularly important in this aspect. One such disease is an obstructive arterial disease affecting millions of people around the world. In recent years, stents and balloon catheters have reached a significant position in the treatment of this condition. Balloon catheters are also successfully used to manage tear ducts, paranasal sinuses, or salivary glands disorders. Modern technology is continually striving to improve the results of previous generations of stents and balloon catheters by refining their design, structure, and constituent materials. These advances result in the development of both successive models of drug-eluting stents (DES) and drug-eluting balloons (DEB). This paper presents milestones in the development of DES and DEB, which are a significant option in the treatment of coronary artery diseases. This report reviews the works related to achievements in construction designs and materials, as well as preparation technologies, of DES and DEB. Special attention was paid to the polymeric biodegradable materials used in the production of the above-mentioned devices. Information was also collected on the various methods of producing drug release coatings and their effectiveness in releasing the active substance.
Collapse
Affiliation(s)
- I. Rykowska
- Faculty of Chemistry, Adam Mickiewicz University, Uniwersytetu Poznańskiego 8, 61-614 Poznań, Poland;
| | - I. Nowak
- Faculty of Chemistry, Adam Mickiewicz University, Uniwersytetu Poznańskiego 8, 61-614 Poznań, Poland;
| | - R. Nowak
- Eye Department, J. Strus City Hospital, Szwajcarska 3, 61-285 Poznań, Poland;
| |
Collapse
|
16
|
Wang D, Serracino-Inglott F, Feng J. Numerical simulations of patient-specific models with multiple plaques in human peripheral artery: a fluid-structure interaction analysis. Biomech Model Mechanobiol 2020; 20:255-265. [PMID: 32915332 PMCID: PMC7892515 DOI: 10.1007/s10237-020-01381-w] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/12/2020] [Accepted: 08/23/2020] [Indexed: 11/30/2022]
Abstract
Atherosclerotic plaque in the femoral is the leading cause of peripheral artery disease (PAD), the worse consequence of which may lead to ulceration and gangrene of the feet. Numerical studies on fluid-structure interactions (FSI) of atherosclerotic femoral arteries enable quantitative analysis of biomechanical features in arteries. This study aims to investigate the hemodynamic performance and its interaction with femoral arterial wall based on the patient-specific model with multiple plaques (calcified and lipid plaques). Three types of models, calcification-only, lipid-only and calcification-lipid models, are established. Hyperelastic material coefficients of the human femoral arteries obtained from experimental studies are employed for all simulations. Oscillation of WSS is observed in the healthy downstream region in the lipid-only model. The pressure around the plaques in the two-plaque model is lower than that in the corresponding one-plaque models due to the reduction of blood flow domain, which consequently diminishes the loading forces on both plaques. Therefore, we found that stress acting on the plaques in the two-plaque model is lower than that in the corresponding one-plaque models. This finding implies that the lipid plaque, accompanied by the calcified plaque around, might reduce its risk of rupture due to the reduced the stress acting on it.
Collapse
Affiliation(s)
- Danyang Wang
- Department of Engineering, Manchester Metropolitan University, Manchester, UK
| | | | - Jiling Feng
- Department of Engineering, Manchester Metropolitan University, Manchester, UK.
| |
Collapse
|
17
|
PANNEERSELVAM NISANTHKUMAR, MUTHUSWAMY SREEKUMAR. DESIGN AND ANALYSIS OF NEW STENT PATTERNS FOR ENHANCED PERFORMANCE. J MECH MED BIOL 2020. [DOI: 10.1142/s0219519420500396] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/18/2022]
Abstract
Deploying a stent to restore blood flow in the coronary artery is very complicated, as its internal diameter is smaller than 3[Formula: see text]mm. It has already been proven that mechanical stresses induced on stent and artery during deployment make the placement of stent very difficult, besides the development of complications due to artery damage. Various stent designs have already been developed, especially in the metallic category. Still, there are possibilities for developing new stent designs and patterns to overcome the complexities of the existing models. Also, the technology of metallic stents can be carried forward towards the development of bioresorbable polymeric stents. In this work, three new stent cell designs (curvature, diamond, and oval) have been proposed to obtain better performance and life. The finite element method is utilized to explore the mechanical behavior of stent expansion and determine the biomechanical stresses imposed on the stent and artery during the stenting procedure. The results obtained have been compared with the available literature and found that the curvature cell design develops lower stresses and, hence, be suitable for better performance and life.
Collapse
Affiliation(s)
- NISANTHKUMAR PANNEERSELVAM
- Department of Mechanical Engineering, Indian Institute of Information Technology, Design and Manufacturing, Kancheepuram Chennai 600127, India
| | - SREEKUMAR MUTHUSWAMY
- Department of Mechanical Engineering, Indian Institute of Information Technology, Design and Manufacturing, Kancheepuram Chennai 600127, India
| |
Collapse
|
18
|
Lee W, Cho SW, Allahwala UK, Bhindi R. Numerical study to identify the effect of fluid presence on the mechanical behavior of the stents during coronary stent expansion. Comput Methods Biomech Biomed Engin 2020; 23:744-754. [PMID: 32427003 DOI: 10.1080/10255842.2020.1763967] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/24/2022]
Abstract
In this study, structural analysis and one-way fluid-structure interaction (FSI) analysis were performed to identify the effect of fluid presence on the mechanical behavior of the stents during stent expansion. An idealized vessel model with stenosis was used for simulation, and stents made of metal and polymer were assumed, respectively. The bilinear model was applied to the stents, and the Mooney-Rivlin model was applied to the arterial wall and plaque. The blood used in the FSI analysis was assumed to be a non-Newtonian fluid. As a result of all numerical simulations, the von Mises stress, the first principal stress and the displacement were calculated as the mechanical behaviors. Through the comparison of the results of the structural analysis with those of the one-way FSI analysis, our results indicated the fluid had no significant influence on the expansion of the metal stent. However, it was found that the expansion of the polymer stent affected by the presence of fluid. These findings meant the one-way FSI technique was suggested to achieve an accurate analysis when targeting a polymer stent for numerical simulation.
Collapse
Affiliation(s)
- Wookjin Lee
- Department of Cardiology, Kolling Institute of Medical Research, Northern Clinical School, Faculty of Medicine and Health, University of Sydney, Sydney, NSW, Australia
| | - Seong Wook Cho
- School of Mechanical Engineering, Chung-Ang University, Seoul, South Korea
| | - Usaid K Allahwala
- Department of Cardiology, Royal North Shore Hospital, University of Sydney, Sydney, NSW, Australia
| | - Ravinay Bhindi
- Department of Cardiology, Royal North Shore Hospital, University of Sydney, Sydney, NSW, Australia
| |
Collapse
|
19
|
Emuna N, Durban D, Osovski S. Sensitivity of Arterial Hyperelastic Models to Uncertainties in Stress-Free Measurements. J Biomech Eng 2019; 140:2683233. [PMID: 30029245 DOI: 10.1115/1.4040400] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/09/2017] [Indexed: 12/14/2022]
Abstract
Despite major advances made in modeling vascular tissue biomechanics, the predictive power of constitutive models is still limited by uncertainty of the input data. Specifically, key measurements, like the geometry of the stress-free (SF) state, involve a definite, sometimes non-negligible, degree of uncertainty. Here, we introduce a new approach for sensitivity analysis of vascular hyperelastic constitutive models to uncertainty in SF measurements. We have considered two vascular hyperelastic models: the phenomenological Fung model and the structure-motivated Holzapfel-Gasser-Ogden (HGO) model. Our results indicate up to 160% errors in the identified constitutive parameters for a 5% measurement uncertainty in the SF data. Relative margins of errors of up to 30% in the luminal pressure, 36% in the axial force, and over 200% in the stress predictions were recorded for 10% uncertainties. These findings are relevant to the large body of studies involving experimentally based modeling and analysis of vascular tissues. The impact of uncertainties on calibrated constitutive parameters is significant in context of studies that use constitutive parameters to draw conclusions about the underlying microstructure of vascular tissues, their growth and remodeling processes, and aging and disease states. The propagation of uncertainties into the predictions of biophysical parameters, e.g., force, luminal pressure, and wall stresses, is of practical importance in the design and execution of clinical devices and interventions. Furthermore, insights provided by the present findings may lead to more robust parameters identification techniques, and serve as selection criteria in the trade-off between model complexity and sensitivity.
Collapse
Affiliation(s)
- Nir Emuna
- Faculty of Aerospace Engineering, Technion-Israel Institute of Technology, Haifa 32000, Israel e-mail:
| | - David Durban
- Faculty of Aerospace Engineering, Technion-Israel Institute of Technology, Haifa 32000, Israel e-mail:
| | - Shmuel Osovski
- Faculty of Mechanical Engineering, Technion-Israel Institute of Technology, Haifa 32000, Israel e-mail:
| |
Collapse
|
20
|
Evaluation of 4D flow MRI-based non-invasive pressure assessment in aortic coarctations. J Biomech 2019; 94:13-21. [PMID: 31326119 DOI: 10.1016/j.jbiomech.2019.07.004] [Citation(s) in RCA: 27] [Impact Index Per Article: 5.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/28/2018] [Revised: 06/12/2019] [Accepted: 07/04/2019] [Indexed: 12/20/2022]
Abstract
Severity of aortic coarctation (CoA) is currently assessed by estimating trans-coarctation pressure drops through cardiac catheterization or echocardiography. In principle, more detailed information could be obtained non-invasively based on space- and time-resolved magnetic resonance imaging (4D flow) data. Yet the limitations of this imaging technique require testing the accuracy of 4D flow-derived hemodynamic quantities against other methodologies. With the objective of assessing the feasibility and accuracy of this non-invasive method to support the clinical diagnosis of CoA, we developed an algorithm (4DF-FEPPE) to obtain relative pressure distributions from 4D flow data by solving the Poisson pressure equation. 4DF-FEPPE was tested against results from a patient-specific fluid-structure interaction (FSI) simulation, whose patient-specific boundary conditions were prescribed based on 4D flow data. Since numerical simulations provide noise-free pressure fields on fine spatial and temporal scales, our analysis allowed to assess the uncertainties related to 4D flow noise and limited resolution. 4DF-FEPPE and FSI results were compared on a series of cross-sections along the aorta. Bland-Altman analysis revealed very good agreement between the two methodologies in terms of instantaneous data at peak systole, end-diastole and time-averaged values: biases (means of differences) were +0.4 mmHg, -1.1 mmHg and +0.6 mmHg, respectively. Limits of agreement (2 SD) were ±0.978 mmHg, ±1.06 mmHg and ±1.97 mmHg, respectively. Peak-to-peak and maximum trans-coarctation pressure drops obtained with 4DF-FEPPE differed from FSI results by 0.75 mmHg and -1.34 mmHg respectively. The present study considers important validation aspects of non-invasive pressure difference estimation based on 4D flow MRI, showing the potential of this technology to be more broadly applied to the clinical practice.
Collapse
|
21
|
Salman HE, Yazicioglu Y. Computational analysis for non-invasive detection of stenosis in peripheral arteries. Med Eng Phys 2019; 70:39-50. [PMID: 31230999 DOI: 10.1016/j.medengphy.2019.06.007] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/26/2018] [Revised: 05/24/2019] [Accepted: 06/10/2019] [Indexed: 01/28/2023]
Abstract
Atherosclerosis usually affects the entire cardiovascular system, including peripheral blood vessels. Peripheral arterial stenosis may indicate possible serious vascular disorders related to more vital organs. If peripheral arterial stenosis can be discerned at an early stage, it can serve as a warning sign to take precautions, such as using more invasive diagnostic techniques or adopting a healthier life style. In this study, peripheral regions, such as the thigh, upper arm, and neck are modelled considering stenosis of their major arteries. Stenosis generates a fluctuating pressure field on the arterial wall, which leads to vibration on the skin's surface. This stenosis-induced pressure field is modelled as a harmonic load and applied to the inner surface of the arterial structure. The vibration response on bare skin is computationally determined using the superposition of modal responses. Realistic geometries and hyperelastic material properties are used in modelling the layers of skin, fat, muscle, and bones. The results indicate that stenosis severities higher than 70% lead to a considerable increase in vibration-response amplitudes, especially at frequencies greater than 250 Hz. The detailed analysis of skin responses provides useful information to detect the stenosis location, where the sum of the vibration amplitudes attains its maximum value around the stenosis.
Collapse
Affiliation(s)
- Huseyin Enes Salman
- Qatar University, Biomedical Research Center, New Research Complex-Zone 5, P.O. Box 2713, Doha, Qatar; Department of Mechanical Engineering, Middle East Technical University, Dumlupinar Street No:1, 06800 Ankara, Turkey.
| | - Yigit Yazicioglu
- Department of Mechanical Engineering, Middle East Technical University, Dumlupinar Street No:1, 06800 Ankara, Turkey.
| |
Collapse
|
22
|
Misiulis E, Džiugys A, Navakas R, Petkus V. A comparative study of methods used to generate the arterial fiber structure in a clinically relevant numerical analysis. INTERNATIONAL JOURNAL FOR NUMERICAL METHODS IN BIOMEDICAL ENGINEERING 2019; 35:e3194. [PMID: 30817080 DOI: 10.1002/cnm.3194] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 05/03/2018] [Revised: 02/13/2019] [Accepted: 02/16/2019] [Indexed: 06/09/2023]
Abstract
The advanced constitutive material models of artery wall require the definition of the mean collagen fiber directions in the material configuration. There are several proposed methods; however, it is unclear how much does the fiber structures obtained by these methods differ one from the other and how much this difference may affect the results of the structural analysis of a clinically relevant scenario. Therefore, in this paper, we address this issue by presenting the results of the comparative study of our developed and currently state-of-the-art fiber definition methods. In addition, we present the verification of our developed numerical model that incorporates the extended Holzapfel-Gasser-Ogden (HGO) constitutive material model and the generalized prestressing algorithm (GPA). In the case of the patient-specific internal carotid artery (ICA), the percentage error of the mean fiber directions defined by different methods does not exceed 17.73% (at least 0.05%, at most 81.82%) and has negligible effect on the stress levels, as the percentage error of the mean circumferential Cauchy stress does not exceed 0.1%. Both fiber definition methods produce comparable fiber structure, but our proposed method has an advantage, as it does not depend on method and software used to model the arterial wall mechanics.
Collapse
Affiliation(s)
- Edgaras Misiulis
- Laboratory of Combustion Processes, Lithuanian Energy Institute, Kaunas, Lithuania
- Kaunas University of Technology, K. Donelaičio St. 73, 44249, Kaunas, Lithuania
| | - Algis Džiugys
- Laboratory of Combustion Processes, Lithuanian Energy Institute, Kaunas, Lithuania
- Kaunas University of Technology, K. Donelaičio St. 73, 44249, Kaunas, Lithuania
| | - Robertas Navakas
- Laboratory of Combustion Processes, Lithuanian Energy Institute, Kaunas, Lithuania
| | - Vytautas Petkus
- Health Telematics Science Institute, Kaunas University of Technology, Kaunas, Lithuania
| |
Collapse
|
23
|
Neumann EE, Young M, Erdemir A. A pragmatic approach to understand peripheral artery lumen surface stiffness due to plaque heterogeneity. Comput Methods Biomech Biomed Engin 2019; 22:396-408. [PMID: 30712373 DOI: 10.1080/10255842.2018.1560427] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/27/2022]
Abstract
The goal of this study was to develop a pragmatic approach to build patient-specific models of the peripheral artery that are aware of plaque inhomogeneity. Patient-specific models using element-specific material definition (to understand the role of plaque composition) and homogeneous material definition (to understand the role of artery diameter and thickness) were automatically built from intravascular ultrasound images of three artery segments classified with low, average, and high calcification. The element-specific material models had average surface stiffness values of 0.0735, 0.0826, and 0.0973 MPa/mm, whereas the homogeneous material models had average surface stiffness values of 0.1392, 0.1276, and 0.1922 MPa/mm for low, average, and high calcification, respectively. Localization of peak lumen stiffness and differences in patient-specific average surface stiffness for homogeneous and element-specific models suggest the role of plaque composition on surface stiffness in addition to local arterial diameter and thickness.
Collapse
Affiliation(s)
- Erica E Neumann
- a Department of Biomedical Engineering , Lerner Research Institute, Cleveland Clinic , Cleveland , OH , USA.,b Computational Biomodeling (CoBi) Core, Lerner Research Institute , Cleveland Clinic , Cleveland , OH , USA
| | - Melissa Young
- c Division of Cardiovascular Diseases , Mayo Clinic , Rochester , MN , USA
| | - Ahmet Erdemir
- a Department of Biomedical Engineering , Lerner Research Institute, Cleveland Clinic , Cleveland , OH , USA.,b Computational Biomodeling (CoBi) Core, Lerner Research Institute , Cleveland Clinic , Cleveland , OH , USA
| |
Collapse
|
24
|
Dynamic Simulation of Biomechanical Behaviour of the Pelvis in the Lateral Impact Loads. JOURNAL OF HEALTHCARE ENGINEERING 2018; 2018:3083278. [PMID: 30319741 PMCID: PMC6167559 DOI: 10.1155/2018/3083278] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 04/21/2018] [Revised: 07/18/2018] [Accepted: 08/05/2018] [Indexed: 11/17/2022]
Abstract
The objective of this study was to develop and validate a novel 3D dynamic model of a pelvic side-impactor system. The biomechanical responses of a pelvic flexible model (having .mnf file suffix) under the lateral impact load for predicting the bone fracture mechanism are investigated as well. The 3D solid model of the side-impactor system was imported into MSC/ADAMS software for analyzing the dynamic model, and the pelvic flexible model was extracted from the CT images of a Chinese female volunteer. The flexible model of the pelvis system was developed considering a wide range of mechanical properties in the bone complex and soft tissue to achieve a realistic biomechanical response during a lateral impact. Good agreements were achieved between the dynamic simulations and the experimental results of pelvic side impacts, in terms of the biomechanical criteria. The dynamic model of impactor system could be employed to investigate the hip protector effectiveness, improving the vehicle safety, and biomechanical response of the other human organs.
Collapse
|
25
|
Han Y, Lu W. Optimizing the deformation behavior of stent with nonuniform Poisson's ratio distribution for curved artery. J Mech Behav Biomed Mater 2018; 88:442-452. [PMID: 30218973 DOI: 10.1016/j.jmbbm.2018.09.005] [Citation(s) in RCA: 17] [Impact Index Per Article: 2.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/24/2018] [Revised: 08/18/2018] [Accepted: 09/02/2018] [Indexed: 01/29/2023]
Abstract
Stent implantation at a highly curved artery has always been a challenge, considering the relatively high chance of in-stent restenosis (ISR) caused by severe straightening effect and high strain energy over the vessel wall. In this paper, a novel optimization based design method was proposed to manipulate the deformation behavior of the common ring-and-link stent. By changing the location of the connection point between rings and links, traditional ring-and-link structure was modified to achiever tunable Poisson's ratio (PR). With the nonuniform cellular structure design method proposed in a previous study, PR distribution of the stent structure was optimized to achieve the desired curvature. As a result, the obtained stent structure with nonuniform PR could perfectly fit into the curved artery after expansion, without causing any obvious vessel straightening. To validate the proposed method, two different vessel models were introduced. Firstly, a short vessel with a constant curvature was set as the design objective, and both numerical and experimental tests were conducted. Further, a patient-specific vessel was applied. Both test results showed that optimized stents would cause much smaller vessel straightening. Moreover, vessels stented by the optimized structures had much lower stress concentration and strain energy. All those properties will decrease the possibility of ISR significantly.
Collapse
Affiliation(s)
- Yafeng Han
- Department of Mechanical Engineering, National University of Singapore, 9 Engineering Drive 1, 117975 Singapore, Singapore
| | - Wenfeng Lu
- Department of Mechanical Engineering, National University of Singapore, 9 Engineering Drive 1, 117975 Singapore, Singapore.
| |
Collapse
|
26
|
Borhani S, Hassanajili S, Ahmadi Tafti SH, Rabbani S. Cardiovascular stents: overview, evolution, and next generation. Prog Biomater 2018; 7:175-205. [PMID: 30203125 PMCID: PMC6173682 DOI: 10.1007/s40204-018-0097-y] [Citation(s) in RCA: 83] [Impact Index Per Article: 13.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/01/2018] [Accepted: 08/25/2018] [Indexed: 12/01/2022] Open
Abstract
Compared to bare-metal stents (BMSs), drug-eluting stents (DESs) have been regarded as a revolutionary change in coronary artery diseases (CADs). Releasing pharmaceutical agents from the stent surface was a promising progress in the realm of cardiovascular stents. Despite supreme advantages over BMSs, in-stent restenosis (ISR) and long-term safety of DESs are still deemed ongoing concerns over clinically application of DESs. The failure of DESs for long-term clinical use is associated with following factors including permanent polymeric coating materials, metallic stent platforms, non-optimal drug releasing condition, and factors that have recently been supposed as contributory factors such as degradation products of polymers, metal ions due to erosion and degradation of metals and their alloys utilizing in some stents as metal frameworks. Discovering the direct relation between stent materials and associating adverse effects is a complicated process, and yet it has not been resolved. For clinical success it is of significant importance to optimize DES design and explore novel strategies to overcome all problems including inflammatory response, delay endothelialization, and sub-acute stent thrombosis (ST) simultaneously. In this work, scientific reports are reviewed particularly focusing on recent advancements in DES design which covers both potential improvements of existing and recently novel prototype stent fabrications. Covering a wide range of information from the BMSs to recent advancement, this study mostly sheds light on DES's concepts, namely stent composition, drug release mechanism, and coating techniques. This review further reports different forms of DES including fully biodegradable DESs, shape-memory ones, and polymer-free DESs.
Collapse
Affiliation(s)
- Setareh Borhani
- Department of Chemical Engineering, School of Chemical and Petroleum Engineering, Shiraz University, Shiraz, Iran
| | - Shadi Hassanajili
- Department of Nanochemical Engineering, School of New Science and Technology, Shiraz University, Shiraz, Iran.
| | - Seyed Hossein Ahmadi Tafti
- Research Center for Advanced Technologies in Cardiovascular Medicine, Tehran Heart Center, Tehran University of Medical Sciences, North Kargar, Tehran, Iran
| | - Shahram Rabbani
- Research Center for Advanced Technologies in Cardiovascular Medicine, Tehran Heart Center, Tehran University of Medical Sciences, North Kargar, Tehran, Iran
| |
Collapse
|
27
|
Farzaneh S, Trabelsi O, Avril S. Inverse identification of local stiffness across ascending thoracic aortic aneurysms. Biomech Model Mechanobiol 2018; 18:137-153. [DOI: 10.1007/s10237-018-1073-0] [Citation(s) in RCA: 32] [Impact Index Per Article: 5.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/02/2018] [Accepted: 08/16/2018] [Indexed: 01/06/2023]
|
28
|
Zhang S, Luo X, Cai Z. Three-dimensional flows in a hyperelastic vessel under external pressure. Biomech Model Mechanobiol 2018; 17:1187-1207. [PMID: 29744606 DOI: 10.1007/s10237-018-1022-y] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/20/2017] [Accepted: 04/25/2018] [Indexed: 11/26/2022]
Abstract
We study the collapsible behaviour of a vessel conveying viscous flows subject to external pressure, a scenario that could occur in many physiological applications. The vessel is modelled as a three-dimensional cylindrical tube of nonlinear hyperelastic material. To solve the fully coupled fluid-structure interaction, we have developed a novel approach based on the Arbitrary Lagrangian-Eulerian (ALE) method and the frontal solver. The method of rotating spines is used to enable an automatic mesh adaptation. The numerical code is verified extensively with published results and those obtained using the commercial packages in simpler cases, e.g. ANSYS for the structure with the prescribed flow, and FLUENT for the fluid flow with prescribed structure deformation. We examine three different hyperelastic material models for the tube for the first time in this context and show that at the small strain, all three material models give similar results. However, for the large strain, results differ depending on the material model used. We further study the behaviour of the tube under a mode-3 buckling and reveal its complex flow patterns under various external pressures. To understand these flow patterns, we show how energy dissipation is associated with the boundary layers created at the narrowest collapsed section of the tube, and how the transverse flow forms a virtual sink to feed a strong axial jet. We found that the energy dissipation associated with the recirculation does not coincide with the flow separation zone itself, but overlaps with the streamlines that divide the three recirculation zones. Finally, we examine the bifurcation diagrams for both mode-3 and mode-2 collapses and reveal that multiple solutions exist for a range of the Reynolds number. Our work is a step towards modelling more realistic physiological flows in collapsible arteries and veins.
Collapse
Affiliation(s)
- Sen Zhang
- Department of Mechanics, Tianjin University, Tianjin, People's Republic of China
| | - Xiaoyu Luo
- School of Mathematics and Statistics, University of Glasgow, Glasgow, UK.
| | - Zongxi Cai
- Department of Mechanics, Tianjin University, Tianjin, People's Republic of China
| |
Collapse
|
29
|
Frecentese S, Argani LP, Movchan AB, Movchan NV, Carta G, Wall ML. Waves and fluid-solid interaction in stented blood vessels. Proc Math Phys Eng Sci 2018; 474:20170670. [PMID: 29434515 PMCID: PMC5806025 DOI: 10.1098/rspa.2017.0670] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/19/2017] [Accepted: 12/18/2017] [Indexed: 11/23/2022] Open
Abstract
This paper focuses on the modelling of fluid–structure interaction and wave propagation problems in a stented artery. Reflection of waves in blood vessels is well documented in the literature, but it has always been linked to a strong variation in geometry, such as the branching of vessels. The aim of this work is to detect the possibility of wave reflection in a stented artery due to the repetitive pattern of the stents. The investigation of wave propagation and possible blockages under time-harmonic conditions is complemented with numerical simulations in the transient regime.
Collapse
Affiliation(s)
- S Frecentese
- Department of Mathematical Sciences, University of Liverpool, Peach Street, Liverpool L69 7ZL, UK
| | - L P Argani
- Department of Mathematical Sciences, University of Liverpool, Peach Street, Liverpool L69 7ZL, UK
| | - A B Movchan
- Department of Mathematical Sciences, University of Liverpool, Peach Street, Liverpool L69 7ZL, UK
| | - N V Movchan
- Department of Mathematical Sciences, University of Liverpool, Peach Street, Liverpool L69 7ZL, UK
| | - G Carta
- Department of Maritime and Mechanical Engineering, Liverpool John Moores University, 3 Byrom Street, Liverpool L3 3AF, UK
| | - M L Wall
- Russells Hall Hospital, The Dudley Group NHS Foundation Trust, Pensnett Road, Dudley DY1 2HQ, UK
| |
Collapse
|
30
|
Beigzadeh B, Mirmohammadi SA, Ayatollahi MR. A numerical study on the effect of geometrical parameters and loading profile on the expansion of stent. Biomed Mater Eng 2017; 28:463-476. [PMID: 28854490 DOI: 10.3233/bme-171691] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/15/2022]
Abstract
BACKGROUND Stenting has been proposed as an effective treatment to restore blood flow in obstructed arteries by plaques. Although several modified designs for stents have been suggested, most designs have the risk of disturbing blood flow. OBJECTIVE The main objective is to propose a stent design to attain a uniform lumen section after stent deployment. METHODS Mechanical response of five different designs of J & J Palmaz-Schatz stent with the presence of plaque and artery are investigated; four stents have variable strut thickness of different magnitudes and the rest one is a uniform-strut-thickness stent. Nonlinear finite element is employed to simulate the expansion procedure of the intended designs using ABAQUS explicit. RESULTS The stent design whose first cell thickness linearly increases by 35 percent, exhibits the best performance, that is it has the lowest recoiling and stress induced in the intima for a given lumen gain. It also enjoys the minimal discrepancy between the final at the distal and proximal ends. CONCLUSIONS A uniform widened artery can be achieved by using the stent design with 35 percent increase in its first cell, which provides the possibility to prevent from disturbing blood flow and consequently post-operation complications.
Collapse
Affiliation(s)
- Borhan Beigzadeh
- Biomechatronics and Cognitive Engineering Research Lab, School of Mechanical Engineering, Iran University of Science and Technology, Tehran, Iran. E-mail:
| | - Seyed Alireza Mirmohammadi
- Fatigue and Fracture Research Lab, School of Mechanical Engineering, Iran University of Science and Technology, Tehran, Iran. E-mail:
| | - Majid Reza Ayatollahi
- Fatigue and Fracture Research Lab, School of Mechanical Engineering, Iran University of Science and Technology, Tehran, Iran. E-mail:
| |
Collapse
|
31
|
Zun PS, Anikina T, Svitenkov A, Hoekstra AG. A Comparison of Fully-Coupled 3D In-Stent Restenosis Simulations to In-vivo Data. Front Physiol 2017; 8:284. [PMID: 28588498 PMCID: PMC5440556 DOI: 10.3389/fphys.2017.00284] [Citation(s) in RCA: 32] [Impact Index Per Article: 4.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/23/2017] [Accepted: 04/19/2017] [Indexed: 01/05/2023] Open
Abstract
We describe our fully-coupled 3D multiscale model of in-stent restenosis, with blood flow simulations coupled to smooth muscle cell proliferation, and report results of numerical simulations performed with this model. This novel model is based on several previously reported 2D models. We study the effects of various parameters on the process of restenosis and compare with in vivo porcine data where we observe good qualitative agreement. We study the effects of stent deployment depth (and related injury score), reendothelization speed, and simulate the effect of stent width. Also we demonstrate that we are now capable to simulate restenosis in real-sized (18 mm long, 2.8 mm wide) vessel geometries.
Collapse
Affiliation(s)
- Pavel S. Zun
- Saint Petersburg State University of Information Technologies, Mechanics and Optics (ITMO) UniversitySt. Petersburg, Russia
- Computational Science Lab, Faculty of Science, Institute for Informatics, University of AmsterdamAmsterdam, Netherlands
| | - Tatiana Anikina
- Saint Petersburg State University of Information Technologies, Mechanics and Optics (ITMO) UniversitySt. Petersburg, Russia
- Computational Science Lab, Faculty of Science, Institute for Informatics, University of AmsterdamAmsterdam, Netherlands
| | - Andrew Svitenkov
- Saint Petersburg State University of Information Technologies, Mechanics and Optics (ITMO) UniversitySt. Petersburg, Russia
| | - Alfons G. Hoekstra
- Saint Petersburg State University of Information Technologies, Mechanics and Optics (ITMO) UniversitySt. Petersburg, Russia
- Computational Science Lab, Faculty of Science, Institute for Informatics, University of AmsterdamAmsterdam, Netherlands
| |
Collapse
|
32
|
Deokar RR, Klamecki BE. Computational Modeling and Comparative Tissue Damage Analysis of Angioplasty and Orbital Atherectomy Interventional Procedures. J Med Device 2017. [DOI: 10.1115/1.4036299] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/08/2022] Open
Abstract
This research was directed toward quantitatively characterizing the effects of arterial mechanical treatment procedures on the stress and strain energy states of the artery wall. Finite element simulations of percutaneous transluminal angioplasty (PTA) and orbital atherectomy (OA) were performed on arterial lesion models with various extents and types of plaque. Stress fields in the artery were calculated and strain energy density was used as an explicit description of potential damage to the artery. The research also included numerical simulations of changes in arterial compliance due to orbital atherectomy. The angioplasty simulations show that the damage energy fields in the media and adventitia are predominant in regions of the lesion that are not protected by a layer of calcification. In addition, it was observed that softening the plaque components leads to a lower peak stress and therefore lesser damage energy in the media and adventitia under the action of a semicompliant balloon. Orbital atherectomy simulations revealed that the major portion of strain energy dissipated is concentrated in the plaque components in contact with the spinning tool. The damage and peak stress fields in the media and adventitia components of the vessel were significantly less. This observation suggests less mechanically induced trauma during a localized procedure like orbital atherectomy. Artery compliance was calculated pre- and post-treatment and an increase was observed after the orbital atherectomy procedure. The localized plaque disruption produced in atherectomy suggests that the undesirable stress states in angioplasty can be mitigated by a combination of procedures such as atherectomy followed by angioplasty.
Collapse
Affiliation(s)
- Rohit R. Deokar
- Department of Mechanical Engineering, University of Minnesota—Twin Cities, 111 Church Street SE, Minneapolis, MN 55455 e-mail:
| | - Barney E. Klamecki
- Department of Mechanical Engineering, University of Minnesota—Twin Cities, 111 Church Street SE, Minneapolis, MN 55455 e-mail:
| |
Collapse
|
33
|
Khosravi A, Bahreinizad H, Bani MS, Karimi A. A numerical study on the application of the functionally graded materials in the stent design. MATERIALS SCIENCE & ENGINEERING. C, MATERIALS FOR BIOLOGICAL APPLICATIONS 2017; 73:182-188. [PMID: 28183596 DOI: 10.1016/j.msec.2016.12.034] [Citation(s) in RCA: 17] [Impact Index Per Article: 2.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 10/12/2016] [Revised: 11/08/2016] [Accepted: 12/07/2016] [Indexed: 11/25/2022]
Abstract
Undesirable deformation of the stent can induce a significant amount of injure not only to the blood vessel but also to the plaque. The objective of this study was to reduce/minimize these undesirable deformations by the application of Functionally Graded Materials (FGM). To do this, Finite Element (FE) method was employed to simulate the expansion of a stent and the corresponding displacement of the stenosis plaque. Three hyperelastic plaque types as well as five elastoplastic stents were simulated. Dogboning, foreshortening, maximum stress in the plaque, and the pressure which is needed to fully expand the stent for different stent materials, were acquired. While all FGMs had lower dogboning in comparison to the stents made of the uniform materials, the stent with the lowest heterogeneous index displayed the lowest amount of dogboning. Steel stent showed the lowest foreshortening and fully expansion pressure but the difference was much lower than that the one for dogboning. Therefore, the FGM with the heterogeneous index of 0.5 is expected to exhibit the most suitable results. In addition, the results revealed that the material parameters has crucial effects on the deformation of the stent and, as a result, as a design point of view the FGM parameters can be tailored to achieve the goal of the biomechanical optimization.
Collapse
Affiliation(s)
- Arezoo Khosravi
- Atherosclerosis Research Center, Baqiyatallah University of Medical science, Tehran, Iran
| | - Hossein Bahreinizad
- Mechanical Engineering Department, Sahand University of Technology, Tabriz, Iran
| | - Milad Salimi Bani
- Mechanical Engineering Department, Iran University of Science and Technology, Tehran, Iran.
| | | |
Collapse
|
34
|
Rastgar Agah M, Laksari K, Assari S, Darvish K. Mechanical behavior of porcine thoracic aorta in physiological and supra-physiological intraluminal pressures. Proc Inst Mech Eng H 2017; 231:326-336. [DOI: 10.1177/0954411917695577] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/16/2022]
Abstract
Understanding the mechanical behavior of aorta under supra-physiological loadings is an important aspect of modeling tissue behavior in various applications that involve large deformations. Utilizing inflation–extension experiments, the mechanical behavior of porcine descending thoracic aortic segments under physiological and supra-physiological intraluminal pressures was investigated. The pressure was changed in the range of 0–70 kPa and the deformation of the segment was determined in three dimensions using a custom-made motion capture system. An orthotropic Fung-type constitutive model was characterized by implementing a novel computationally efficient framework that ensured material stability for numerical simulations. The nonlinear rising trend of circumferential stretch ratio [Formula: see text] from outer toward inner wall was significantly increased at higher pressures. The increase in [Formula: see text] from physiological pressure (13 kPa) to 70 kPa was 13% at the outer wall and 22% at the inner wall; in this pressure range, the longitudinal stretch ratio [Formula: see text] increased 20%. A significant nonlinearity in the material behavior was observed as in the same pressure range, and the circumferential and longitudinal Cauchy stresses at the inner wall were increased 16 and 18 times, respectively. The overall constitutive model was verified in several loading paths in the [Formula: see text] space to confirm its applicability in multi-axial loading conditions.
Collapse
Affiliation(s)
- Mobin Rastgar Agah
- Department of Mechanical Engineering, Temple University, Philadelphia, PA, USA
| | - Kaveh Laksari
- Department of Mechanical Engineering, Temple University, Philadelphia, PA, USA
| | - Soroush Assari
- Department of Mechanical Engineering, Temple University, Philadelphia, PA, USA
| | - Kurosh Darvish
- Department of Mechanical Engineering, Temple University, Philadelphia, PA, USA
| |
Collapse
|
35
|
Cooney GM, Lake SP, Thompson DM, Castile RM, Winter DC, Simms CK. Uniaxial and biaxial tensile stress–stretch response of human linea alba. J Mech Behav Biomed Mater 2016; 63:134-140. [DOI: 10.1016/j.jmbbm.2016.06.015] [Citation(s) in RCA: 23] [Impact Index Per Article: 2.9] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/14/2016] [Revised: 06/07/2016] [Accepted: 06/12/2016] [Indexed: 12/18/2022]
|
36
|
Laksari K, Shahmirzadi D, Acosta CJ, Konofagou E. Energy-based constitutive modelling of local material properties of canine aortas. ROYAL SOCIETY OPEN SCIENCE 2016; 3:160365. [PMID: 27703701 PMCID: PMC5043320 DOI: 10.1098/rsos.160365] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 05/24/2016] [Accepted: 08/24/2016] [Indexed: 05/05/2023]
Abstract
This study aims at determining the in vitro anisotropic mechanical behaviour of canine aortic tissue. We specifically focused on spatial variations of these properties along the axis of the vessel. We performed uniaxial stretch tests on canine aortic samples in both circumferential and longitudinal directions, as well as histological examinations to derive the tissue's fibre orientations. We subsequently characterized a constitutive model that incorporates both phenomenological and structural elements to account for macroscopic and microstructural behaviour of the tissue. We showed the two fibre families were oriented at similar angles with respect to the aorta's axis. We also found significant changes in mechanical behaviour of the tissue as a function of axial position from proximal to distal direction: the fibres become more aligned with the aortic axis from 46° to 30°. Also, the linear shear modulus of media decreased as we moved distally along the aortic axis from 139 to 64 kPa. These changes derived from the parameters in the nonlinear constitutive model agreed well with the changes in tissue structure. In addition, we showed that isotropic contribution, carried by elastic lamellae, to the total stress induced in the tissue decreases at higher stretch ratios, whereas anisotropic stress, carried by collagen fibres, increases. The constitutive models can be readily used to design computational models of tissue deformation during physiological loading cycles. The findings of this study extend the understanding of local mechanical properties that could lead to region-specific diagnostics and treatment of arterial diseases.
Collapse
Affiliation(s)
- Kaveh Laksari
- Department of Bioengineering, Stanford University, Stanford, CA, USA
- Author for correspondence: Kaveh Laksari e-mail:
| | - Danial Shahmirzadi
- Department of Mechanical Engineering, Stevens Institute of Technology, Hoboken, NJ, USA
| | - Camilo J. Acosta
- Ultrasound and Elasticity Imaging Lab (UEIL), Department of Biomedical Engineering, Columbia University, New York, NY, USA
| | - Elisa Konofagou
- Ultrasound and Elasticity Imaging Lab (UEIL), Department of Biomedical Engineering, Columbia University, New York, NY, USA
- Department of Radiology, Columbia University, New York, NY, USA
| |
Collapse
|
37
|
Yu K, Hu F, Gu X. A Biomechanical Study on the Effects of Struts of Z-Shaped Stent-Grafts on the Blood Vessel Wall Tissue Layers1. J Med Device 2016. [DOI: 10.1115/1.4033874] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/08/2022] Open
Affiliation(s)
- Kai Yu
- Institute for Minimally Invasive Therapy, University of Shanghai for Science and Technology, Shanghai 200093, China
| | - Fanqiu Hu
- Institute for Minimally Invasive Therapy, University of Shanghai for Science and Technology, Shanghai 200093, China
| | - Xuelian Gu
- Institute for Minimally Invasive Therapy, University of Shanghai for Science and Technology, Shanghai 200093, China e-mail:
| |
Collapse
|
38
|
Towards the development of an in vitro model of atherosclerotic peripheral vessels for evaluating drug-coated endovascular technologies. Drug Discov Today 2016; 21:1512-1520. [PMID: 27297733 DOI: 10.1016/j.drudis.2016.05.019] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/01/2016] [Revised: 04/27/2016] [Accepted: 05/27/2016] [Indexed: 11/20/2022]
Abstract
Here, we review the in vitro models used to evaluate drug-coated endovascular technologies. The models are assessed in the context of representing the drug transport/uptake and mechanical properties of atherosclerotic peripheral vessels. Studies to date have incorporated a vessel-simulating hydrogel compartment to examine drug elution from endovascular devices. However, comparisons between in vitro models and atherosclerotic tissue are difficult because ex vivo data are limited in their applicability to diseased peripheral vessels. Furthermore, appropriate ex vivo mechanical properties are not incorporated into these models. Therefore, there is a need to characterise the drug transport/uptake properties of appropriate atherosclerotic tissue and incorporate existing ex vivo mechanical data into current in vitro models to more accurately represent drug behaviour in atherosclerotic peripheral vessels.
Collapse
|
39
|
The aortic reservoir-wave as a paradigm for arterial haemodynamics: insights from three-dimensional fluid-structure interaction simulations in a model of aortic coarctation. J Hypertens 2016; 33:554-63; discussion 563. [PMID: 25479031 DOI: 10.1097/hjh.0000000000000449] [Citation(s) in RCA: 18] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/26/2022]
Abstract
BACKGROUND The reservoir-wave paradigm considers aortic pressure as the superposition of a 'reservoir pressure', directly related to changes in reservoir volume, and an 'excess' component ascribed to wave dynamics. The change in reservoir pressure is assumed to be proportional to the difference between aortic inflow and outflow (i.e. aortic volume changes), an assumption that is virtually impossible to validate in vivo. The aim of this study is therefore to apply the reservoir-wave paradigm to aortic pressure and flow waves obtained from three-dimensional fluid-structure interaction simulations in a model of a normal aorta, aortic coarctation (narrowed descending aorta) and stented coarctation (stiff segment in descending aorta). METHOD AND RESULTS We found no unequivocal relation between the intraaortic volume and the reservoir pressure for any of the simulated cases. When plotted in a pressure-volume diagram, hysteresis loops are found that are looped in a clockwise way indicating that the reservoir pressure is lower than the pressure associated with the change in volume. The reservoir-wave analysis leads to very high excess pressures, especially for the coarctation models, but to surprisingly little changes of the reservoir component despite the impediment of the buffer capacity of the aorta. CONCLUSION With the observation that reservoir pressure is not related to the volume in the aortic reservoir in systole, an intrinsic assumption in the wave-reservoir concept is invalidated and, consequently, also the assumption that the excess pressure is the component of pressure that can be attributed to wave travel and reflection.
Collapse
|
40
|
Xu LX. An RF device for effective thermal treatment of atherosclerosis. ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY. IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY. ANNUAL INTERNATIONAL CONFERENCE 2016; 2015:1303-6. [PMID: 26736507 DOI: 10.1109/embc.2015.7318607] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/09/2022]
Abstract
There is a high rate of restenosis after current treatment of atherosclerosis, which is often associated to the damage of the vascular endothelial cell layer during therapeutic process. Lately, it was found that the plaque was related to the local proliferation of vascular smooth muscle cells (VSMCs) [1, 2]. An RF angioplasty balloon is designed to selectively treat the proliferated region while keeping the intima layer intact. Micro-electrodes are integrated onto the balloon surface, and cooling agent circulates inside to lower the temperature of the vascular endothelium. A controlled thin layer thermal treatment region has been achieved using this device through theoretical modeling and experimental validation. The penetration of RF energy heats up to ablate the plaque and also suppress the proliferation of VSMCs.
Collapse
|
41
|
Bukala J, Kwiatkowski P, Malachowski J. Numerical analysis of stent expansion process in coronary artery stenosis with the use of non-compliant balloon. Biocybern Biomed Eng 2016. [DOI: 10.1016/j.bbe.2015.10.009] [Citation(s) in RCA: 10] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/01/2023]
|
42
|
Hajiali Z, Dabagh M, Debusschere N, Beule MD, Jalali P. Tissue prolapse and stresses in stented coronary arteries: A computer model for multi-layer atherosclerotic plaque. Comput Biol Med 2015; 66:39-46. [DOI: 10.1016/j.compbiomed.2015.08.014] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/18/2015] [Revised: 08/14/2015] [Accepted: 08/22/2015] [Indexed: 11/17/2022]
|
43
|
Taelman L, Bols J, Degroote J, Muthurangu V, Panzer J, Vierendeels J, Segers P. Differential impact of local stiffening and narrowing on hemodynamics in repaired aortic coarctation: an FSI study. Med Biol Eng Comput 2015; 54:497-510. [PMID: 26142885 DOI: 10.1007/s11517-015-1336-1] [Citation(s) in RCA: 14] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/08/2014] [Accepted: 06/15/2015] [Indexed: 12/22/2022]
Abstract
Even after successful treatment of aortic coarctation, a high risk of cardiovascular morbidity and mortality remains. Uncertainty exists on the factors contributing to this increased risk among which are the presence of (1) a residual narrowing leading to an additional resistance and (2) a less distensible zone disturbing the buffer function of the aorta. As the many interfering factors and adaptive physiological mechanisms present in vivo prohibit the study of the isolated impact of these individual factors, a numerical fluid-structure interaction model is developed to predict central hemodynamics in coarctation treatment. The overall impact of a stiffening on the hemodynamics is limited, with a small increase in systolic pressure (up to 8 mmHg) proximal to the stiffening which is amplified with increasing stiffening and length. A residual narrowing, on the other hand, affects the hemodynamics significantly. For a short segment (10 mm), the combination of a stiffening and narrowing (coarctation index 0.5) causes an increase in systolic pressure of 58 mmHg, with 31 mmHg due to narrowing and an additional 27 mmHg due to stiffening. For a longer segment (25 mm), an increase in systolic pressure of 50 mmHg is found, of which only 9 mmHg is due to stiffening.
Collapse
Affiliation(s)
- Liesbeth Taelman
- IBiTech-bioMMeda, iMinds Medical IT, Faculty of Engineering and Architecture, Ghent University, De Pintelaan 185, 9000, Ghent, Belgium.
| | - Joris Bols
- Department of Flow, Heat and Combustion Mechanics, Faculty of Engineering and Architecture, Ghent University, Sint-Pietersnieuwstraat 41, 9000, Ghent, Belgium
| | - Joris Degroote
- Department of Flow, Heat and Combustion Mechanics, Faculty of Engineering and Architecture, Ghent University, Sint-Pietersnieuwstraat 41, 9000, Ghent, Belgium
| | - Vivek Muthurangu
- Centre for Cardiovascular MR, UCL Institute of Child Health, London Great Ormond Street Hospital for Children, Great Ormond Street, London, WC1N 3JH, UK
| | - Joseph Panzer
- Paediatric Cardiology, Ghent University Hospital, De Pintelaan 185, 9000, Ghent, Belgium
| | - Jan Vierendeels
- Department of Flow, Heat and Combustion Mechanics, Faculty of Engineering and Architecture, Ghent University, Sint-Pietersnieuwstraat 41, 9000, Ghent, Belgium
| | - Patrick Segers
- IBiTech-bioMMeda, iMinds Medical IT, Faculty of Engineering and Architecture, Ghent University, De Pintelaan 185, 9000, Ghent, Belgium
| |
Collapse
|
44
|
Schiavone A, Zhao LG. A study of balloon type, system constraint and artery constitutive model used in finite element simulation of stent deployment. ACTA ACUST UNITED AC 2015. [DOI: 10.1186/s40759-014-0002-x] [Citation(s) in RCA: 33] [Impact Index Per Article: 3.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/10/2022]
Abstract
Abstract
Background
Finite element is an effective tool to simulate stent expansion inside stenotic arteries, which provides an insightful understanding of the biomechanical behaviour of the whole stent-artery system during the procedure. The choice of balloon type, system constraint and artery constitutive model plays an important role in finite element simulation of stent deployment.
Methods
Commercial finite element package ABAQUS was used to model the expansion of Xience stent inside a diseased artery with 40% stenosis. The arterial wall, consisting of intima, media and adventitia layers, and the stenotic plaque were described by different hyperelastic models. Both folded and rubber balloons were considered and inflated with a linearly increasing pressure of 1.4 MPa. Simulations were also carried out by considering free, partially and fully constrained arteries.
Results
Folded balloon produces sustained stent expansion under a lower pressure when compared to rubber balloon, leading to increased stress level and enhanced final expansion for the system. Fully constrained artery reduces the stent expansion when compared to free and partially constrained arteries, due to the increased recoiling effect. Stress in the artery-plaque system has higher magnitude for stent expansion in a free artery due to more severe stretch. Calcified plaque limits stent expansion considerably when compared to hypocellular plaque. The negligence of the second stretch invariant in the strain energy potential leads to the disappearance of saturation behaviour during stent expansion. The use of anisotropic artery model reduces the system expansion at peak pressure when compared to the isotropic model, but with an increased final diameter due to reduced recoiling effect. The stress distribution in the artery-plaque system is also different for different combinations of artery and plaque constitutive models.
Conclusions
Folded balloon should be used in the simulation of stent deployment, with the artery partially constrained using spring elements with a proper stiffness constant. The blood vessel should be modelled as a three-layer structure using a hyperelastic potential that considers both the first and second stretch invariants as well as the anisotropy. The composition of the plaque also has to be considered due to its major effect on stent deployment.
Collapse
|
45
|
Uniaxial and biaxial mechanical properties of porcine linea alba. J Mech Behav Biomed Mater 2015; 41:68-82. [DOI: 10.1016/j.jmbbm.2014.09.026] [Citation(s) in RCA: 34] [Impact Index Per Article: 3.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/24/2014] [Revised: 09/23/2014] [Accepted: 09/26/2014] [Indexed: 11/18/2022]
|
46
|
Delgadillo JOV, Delorme S, Thibault F, DiRaddo R, Hatzikiriakos SG. Large Deformation Characterization of Porcine Thoracic Aortas: Inverse Modeling Fitting of Uniaxial and Biaxial Tests. ACTA ACUST UNITED AC 2015. [DOI: 10.4236/jbise.2015.810069] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/20/2022]
|
47
|
Altnji HE, Bou-Saïd B, Walter-Le Berre H. Morphological and stent design risk factors to prevent migration phenomena for a thoracic aneurysm: A numerical analysis. Med Eng Phys 2015; 37:23-33. [DOI: 10.1016/j.medengphy.2014.09.017] [Citation(s) in RCA: 29] [Impact Index Per Article: 3.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/20/2013] [Revised: 08/21/2014] [Accepted: 09/30/2014] [Indexed: 10/24/2022]
|
48
|
|
49
|
Schiavone A, Zhao L, Abdel-Wahab A. Effects of material, coating, design and plaque composition on stent deployment inside a stenotic artery—Finite element simulation. MATERIALS SCIENCE & ENGINEERING. C, MATERIALS FOR BIOLOGICAL APPLICATIONS 2014; 42:479-88. [DOI: 10.1016/j.msec.2014.05.057] [Citation(s) in RCA: 47] [Impact Index Per Article: 4.7] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Received: 12/19/2013] [Revised: 04/18/2014] [Accepted: 05/29/2014] [Indexed: 01/19/2023]
|
50
|
Lyons M, Winter DC, Simms CK. Mechanical characterisation of porcine rectus sheath under uniaxial and biaxial tension. J Biomech 2014; 47:1876-84. [DOI: 10.1016/j.jbiomech.2014.03.009] [Citation(s) in RCA: 24] [Impact Index Per Article: 2.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/29/2013] [Revised: 02/12/2014] [Accepted: 03/01/2014] [Indexed: 12/11/2022]
|