1
|
Verhulst A, Dehmel B, Lindner E, Akerman ME, D'Haese PC. Oxalobacter formigenes treatment confers protective effects in a rat model of primary hyperoxaluria by preventing renal calcium oxalate deposition. Urolithiasis 2022; 50:119-130. [PMID: 35122487 DOI: 10.1007/s00240-022-01310-9] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/04/2021] [Accepted: 01/21/2022] [Indexed: 01/25/2023]
Abstract
In primary hyperoxaluria, increased hepatic oxalate production sometimes leads to severe nephrocalcinosis and early end-stage kidney disease. Oral administration of Oxalobacter formigenes (O. formigenes), an oxalate-degrading bacterium, is thought to derive oxalate from systemic sources by inducing net enteric oxalate secretion. Here, the impact of O. formigenes on nephrocalcinosis was investigated in an ethylene glycol rat model mimicking hepatic oxalate overproduction in primary hyperoxaluria. Eighteen rats were administered ethylene glycol (0.75% in drinking water) for 6 weeks, of which 9 were treated by oral gavage with O. formigenes and 9 received vehicle. Five control rats did not receive ethylene glycol or O. formigenes. Plasma and urinary oxalate levels, calcium oxalate crystalluria, urinary volume, fluid intake, and serum creatinine were monitored during the study. On killing, nephrocalcinosis was quantified. Ethylene glycol intake induced pronounced hyperoxalemia, hyperoxaluria, calcium oxalate crystalluria and nephrocalcinosis. Concomitant O. formigenes treatment partially prevented the ethylene glycol-induced increase in plasma oxalate and completely prevented nephrocalcinosis. Urinary oxalate excretion was not reduced by O. formigenes treatment. Nevertheless, absence of crystals in renal tissue of O. formigenes-treated ethylene glycol animals indicates that the propensity for oxalate to crystallize in the kidneys was reduced compared to non-treated animals. This is supported by the lower plasma oxalate concentrations in O. formigenes-treated animals. This study shows a beneficial effect of O. formigenes treatment on ethylene glycol-induced hyperoxalemia and nephrocalcinosis, and thus supports a possible beneficial effect of O. formigenes in primary hyperoxaluria.
Collapse
Affiliation(s)
- A Verhulst
- Laboratory of Pathophysiology, University of Antwerp, Universiteitsplein 1, 2610, Antwerp, Belgium.
| | | | | | | | - P C D'Haese
- Laboratory of Pathophysiology, University of Antwerp, Universiteitsplein 1, 2610, Antwerp, Belgium
| |
Collapse
|
2
|
Lindner E, Kunze U. Notizen: Das Verhalten von Tetraorganostannanen gegenüber wasserhaltigem Schwefeldioxid / The Behaviour of Tetraorganostannanes towards aqueous Sulfurdioxide. ACTA ACUST UNITED AC 2014. [DOI: 10.1515/znb-1971-0223] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/15/2022]
Affiliation(s)
- E. Lindner
- Institut für Anorganische Chemie II der Universität Erlangen-Nürnberg
| | - U. Kunze
- Institut für Anorganische Chemie II der Universität Erlangen-Nürnberg
| |
Collapse
|
3
|
Lindner E, Berke H. Über das Verhalten von Dithiophosphinatokomplexen des Rheniums gegenüber Ammoniak / About the Behavior of Dithiophosphinato Complexes of Rhenium towards Ammonia. ACTA ACUST UNITED AC 2014. [DOI: 10.1515/znb-1972-0708] [Citation(s) in RCA: 12] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/15/2022]
Abstract
According to eq. (1) the hitherto unknown (C2H5)2PSS--bridged [ (C2H5)2PSSRe (CO) 3NH3]2 (1) is obtained by reaction of [(C2H5)2PSSRe(CO)2]2 with liquid ammonia between -70° and -30°. The complex can be transformed into the monomeric (C2H5)2PSSRe (CO) 3NH3 according to eq. (2) at room temperature in THF. The 1H NMR and IR spectra of the newly prepared compounds are discussed.
Collapse
Affiliation(s)
- E. Lindner
- Lehrstuhl für Anorganische Chemie II der Universität Tübingen
| | - H. Berke
- Lehrstuhl für Anorganische Chemie II der Universität Tübingen
| |
Collapse
|
4
|
Lindner E, Berke H. Notizen: Einschiebung von Keten in die Mn-H-Bindung von Metallcarbonylwasserstoff-Verbindungen / Insertion of Ketene into the Mn-H-Linkage of Metalcarbonylhydrogen Compounds. Zeitschrift für Naturforschung B 2014. [DOI: 10.1515/znb-1974-3-435] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/15/2022]
Affiliation(s)
- E. Lindner
- Lehrstuhl für Anorganische Chemie II der Universität Tübingen
| | - H. Berke
- Lehrstuhl für Anorganische Chemie II der Universität Tübingen
| |
Collapse
|
5
|
Abstract
The new complexes (OC)5MSC(X)Y (8-5) are obtained by reaction of (OC)5MTHF (1) [M = Cr (a), Mo (b), W (c)] with different thiocarbonate, thiourea and thiourethane ligands S = C(X)Y (2a-h). Structure and bonding conditions are discussed on the basis of their IR and 13C NMR spectra. From the spectroscopic data the ligands 2a-h can be arranged in a row with increasing π-acceptor properties.
Collapse
Affiliation(s)
- E. Lindner
- Institut für Anorganische Chemie der Universität Tübingen
| | - W. Nagel
- Institut für Anorganische Chemie der Universität Tübingen
| |
Collapse
|
6
|
Lindner E, Matejcek KM. Notizen: Darstellung und Eigenschaften von π-Cyclo-pentadienyldicarbonyl(diäthyldithiophosphinato)-molybdän( + II) / Preparation and Properties of π-Cyclopentadienyldicar-bonyl (diethyldithiophosphinato) -molybdenum ( + II). Zeitschrift für Naturforschung B 2014. [DOI: 10.1515/znb-1971-0824] [Citation(s) in RCA: 7] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/15/2022]
Affiliation(s)
- E. Lindner
- Institut für Anorganische Chemie II der Universität Erlangen-Nürnberg
| | - K.-M. Matejcek
- Institut für Anorganische Chemie II der Universität Erlangen-Nürnberg
| |
Collapse
|
7
|
Lindner E, Ebert HD. Notizen: Darstellung und Eigenschaften neuer Perfluoracyldiarylphosphine / Preparation and Properties of New Perfluoroacyldiarylphosphines. Zeitschrift für Naturforschung B 2014. [DOI: 10.1515/znb-1971-0721] [Citation(s) in RCA: 8] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/15/2022]
Affiliation(s)
- E. Lindner
- Institut für Anorganische Chemie II der Universität Erlangen-Nürnberg
| | - H.-D. Ebert
- Institut für Anorganische Chemie II der Universität Erlangen-Nürnberg
| |
Collapse
|
8
|
König E, Lindner E, Ritter G. Notizen: 2T2-Grundzustand im Tris(dithioacetylacetonato)eisen(III) und das Auftreten von 6A1—2T2-Übergängen in [FeIII—S6]-Komplexen. Zeitschrift für Naturforschung B 2014. [DOI: 10.1515/znb-1970-0723] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/15/2022]
Affiliation(s)
- E. König
- Institute der Universität Erlangen-Nürnberg, 8520 Erlangen
| | - E. Lindner
- Institute der Universität Erlangen-Nürnberg, 8520 Erlangen
| | - G. Ritter
- Institute der Universität Erlangen-Nürnberg, 8520 Erlangen
| |
Collapse
|
9
|
Lindner E, Frembs DWR, Langner D. Bis(organosulfinato)-pyridin-Komplexe von Zink(II) / Bis(organosulfinato)pyridine Complexes of Zinc(II). Zeitschrift für Naturforschung B 2014. [DOI: 10.1515/znb-1974-7-827] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/15/2022]
Abstract
According to equations (1) and (2) new bis(organosulfinato)mono and bis(pyridine) complexes of zinc with coordination numbers 4, 5 and 6 are described. The structures are discussed pn the basis of the IR spectra of the compounds.
Collapse
Affiliation(s)
- E. Lindner
- Lehrstuhl für Anorganische Chemie II der Universität Tübingen
| | - D. W. R. Frembs
- Lehrstuhl für Anorganische Chemie II der Universität Tübingen
| | - D. Langner
- Lehrstuhl für Anorganische Chemie II der Universität Tübingen
| |
Collapse
|
10
|
Affiliation(s)
- W. Hieber
- Anorganisch-chemisches Laboratorium der TH München
| | - E. Lindner
- Anorganisch-chemisches Laboratorium der TH München
| |
Collapse
|
11
|
Lindner E, Lorenz IP. Notizen: Bis(p-toluolsulfinato-S)-tetrapyridin-kupfer(II). Bis (p-toluenesulfinato-S) -tetrapyridine-copper (II). Zeitschrift für Naturforschung B 2014. [DOI: 10.1515/znb-1972-0938] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/15/2022]
Affiliation(s)
- E. Lindner
- Lehrstuhl für Anorganische Chemie II der Universität Tübingen
| | - I.-P. Lorenz
- Lehrstuhl für Anorganische Chemie II der Universität Tübingen
| |
Collapse
|
12
|
Graser A, Melzer A, Lindner E, Nagel D, Herrmann K, Stieber P, Schirra J, Mansmann U, Reiser MF, Göke B, Kolligs FT. Magnetic resonance colonography for the detection of colorectal neoplasia in asymptomatic adults. Gastroenterology 2013; 144:743-750.e2. [PMID: 23415805 DOI: 10.1053/j.gastro.2012.12.041] [Citation(s) in RCA: 38] [Impact Index Per Article: 3.5] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 08/16/2012] [Revised: 12/08/2012] [Accepted: 12/12/2012] [Indexed: 12/19/2022]
Abstract
BACKGROUND & AIMS Colonoscopy is the preferred screening test for colorectal neoplasia; the fecal occult blood test (FOBT) detects neoplasias with low levels of sensitivity. Computed tomographic colonography detects neoplasias with high levels of sensitivity but involves exposure to radiation. We investigated whether magnetic resonance colonography (MRC) can be used to screen for colorectal adenomas and cancers. METHODS We analyzed data from 286 asymptomatic adults (40-82 years old) who underwent 3 Tesla MRC and colonoscopic examinations on the same day. FOBT was performed before bowel preparation. Colonoscopists were initially blinded to the findings on MRC and unblinded after withdrawal from the respective segments. Sensitivities for adenoma and per-patient sensitivities and specificities were calculated based on the unblinded results of colonoscopy. RESULTS We detected 133 adenomas and 2 cancers in 86 patients; 37 adenomas were ≥6 mm, and 20 adenomas were advanced. Sensitivities of MRC and colonoscopy for adenomas ≥6 mm were 78.4% (95% confidence interval [CI], 61.8-90.2) and 97.3% (95% CI, 85.8-99.9); for advanced adenomas these values were 75% (95% CI, 50.9-91.3) and 100% (95% CI, 83.2-100.0), respectively. MRC identified 87.1% (95% CI, 70.2-96.4), colonoscopy 96.8% (95% CI, 83.3-99.9), and FOBT 10.0% (95% CI, 2.1-26.5) of individuals with adenomas ≥6 mm and 83.8% (95% CI, 58.6-96.4), 100% (95% CI, 81.5-100.0), and 17.6% (95% CI, 3.8-43.4) of individuals with advanced neoplasia. Specificities of MRC, colonoscopy, and FOBT for individuals with adenomas ≥6 mm were 95.3% (95% CI, 91.9-97.5), 96.9% (95% CI, 93.9-98.6), and 91.8% (95% CI, 87.6-94.9), respectively. CONCLUSIONS 3 Tesla MRC detects colorectal adenomas ≥6 mm and advanced neoplasia with high levels of sensitivity and specificity. Although MRC detects colorectal neoplasia with lower levels of sensitivity than colonoscopy, it strongly outperforms one-time FOBT.
Collapse
Affiliation(s)
- Anno Graser
- Department of Clinical Radiology, University of Munich, Munich, Germany.
| | | | | | | | | | | | | | | | | | | | | |
Collapse
|
13
|
Lindner E, Weinberger A, Kirschkamp T, El-Shabrawi Y, Barounig A. Near-Infrared Autofluorescence and Indocyanine Green Angiography in Central Serous Chorioretinopathy. Ophthalmologica 2012; 227:34-8. [DOI: 10.1159/000331987] [Citation(s) in RCA: 7] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [What about the content of this article? (0)] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/15/2011] [Accepted: 08/12/2011] [Indexed: 11/19/2022]
|
14
|
Meier WP, Strähle J, Lindner E. Das Verhalten von Mono- und Diorganylphosphansulfiden gegenüber Metallcarbonylsystemen. VIII [1]; Die Kristall- und Molekülstruktur von Pentacarbonyl(dimethylmercaptophosphan)-chrom. Z Anorg Allg Chem 2011. [DOI: 10.1002/zaac.654270207] [Citation(s) in RCA: 15] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [What about the content of this article? (0)] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/10/2022]
|
15
|
Kahan Z, Spanik S, Wagnerova M, Jassem J, Skacel T, Elandt K, Fitzthum E, Lindner E, Zielinski C, Brodowicz T. Health-related quality of life (HQOL) and early survival outcome of the randomized adjuvant dose-dense (dd) FEC 75 versus FEC 90 CECOG study. J Clin Oncol 2010. [DOI: 10.1200/jco.2010.28.15_suppl.e11058] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/20/2022] Open
|
16
|
Badian M, Dabrowski J, Grigoleit HG, Lieb W, Lindner E, Rupp W. Über die Wirkung von Forskolin-Augentropfen auf den Augeninnendruck gesunder männlicher Personen. Klin Monbl Augenheilkd 2008; 185:522-6. [PMID: 6543235 DOI: 10.1055/s-2008-1054687] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [What about the content of this article? (0)] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/21/2022]
Abstract
Suspensions of Forskolin in concentrations of 0.3; 0.6; and 1.0% decreased effectively the intraocular pressure of healthy subjects when instillated in the conjunctival sac. The suspensions were compared with placebo in double blind studies. The maximum effect was reached 3 hours after application of the 0.3% (22.8%) and 0.6% (27.8%) suspensions and 4 hours after the 1.0% (26.5%) suspension. The higher concentrations decreased the intraocular pressure to the same extent as the lowest concentration but the effect lasted longer: 4 hours after instillation of the 0.3% suspension, 5 hours after instillation of the 0.6% suspension and 7 hours after the 1.0% suspension. The suspensions were well tolerated. Subjective sensations like burning, itching and augmentated lacrimation were observed only in a minor amount and for a short period of time.
Collapse
|
17
|
Wakatsuki Y, Yamazaki H, Lindner E, Bosamle A. (1, 3-Butadiene-1, 4-Diyl)(η5
-Cyclopentadienyl)-(Triphenylphosphine)Cobalt with Various Substituents. ACTA ACUST UNITED AC 2007. [DOI: 10.1002/9780470132579.ch34] [Citation(s) in RCA: 9] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [What about the content of this article? (0)] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/21/2023]
|
18
|
Affiliation(s)
- E. Lindner
- a Institut für Anorganische Chemie der Universität Tübingen Auf der Morgenstelle , 18, D-7400, Tübingen , 1
| | - R. Fawzi
- a Institut für Anorganische Chemie der Universität Tübingen Auf der Morgenstelle , 18, D-7400, Tübingen , 1
| |
Collapse
|
19
|
Katz LN, Lindner E, Landt H. ON THE NATURE OF THE SUBSTANCE(S) PRODUCING PAIN IN CONTRACTING SKELETAL MUSCLE: ITS BEARING ON THE PROBLEMS OF ANGINA PECTORIS AND INTERMITTENT CLAUDICATION. J Clin Invest 2006; 14:807-21. [PMID: 16694351 PMCID: PMC424733 DOI: 10.1172/jci100729] [Citation(s) in RCA: 28] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/17/2022] Open
Affiliation(s)
- L N Katz
- Heart Station and the Cardiovascular Laboratory, Department of Physiology, Michael Reese Hospital, Chicago
| | | | | |
Collapse
|
20
|
Shamiyeh A, Lindner E, Danis J, Schwarzenlander K, Wayand W. Short- versus long-sequence MRI cholangiography for the preoperative imaging of the common bile duct in patients with cholecystolithiasis. Surg Endosc 2005; 19:1130-4. [PMID: 16021379 DOI: 10.1007/s00464-004-2167-6] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [MESH Headings] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/07/2004] [Accepted: 02/11/2005] [Indexed: 12/25/2022]
Abstract
BACKGROUND This study aimed to compare an 18-s fast spin echo magnetic resonance image sequence (coronal thick-section two-dimensional breathhold) with a three-dimensional axial and coronal thin-section sequence and its secondary reconstruction, and to assess its value in the diagnosis of bile duct pathologies, particularly common bile duct stones (CBDS) before laparoscopic cholecystectomy. METHODS This study prospectively included 72 patients. Because of protocol violations, 14 of these patients had to be excluded. Thus, 58 patients (29 Man and 29 women with a mean age of 51 years) who had cholecystolithiasis or suspected choledocholithiasis were evaluated. Magnetic resonance cholangiopancreatography (MRCP) was performed for all patients with a fast sequence (18 s) and a long sequence (coronal oblique and axial respiratory triggered; 16 min). Two radiologists, blinded with respect to diagnosis, evaluated all the radiographic images. The MRCP results were confirmed for all the patients: 20 by endoscopic retrograde cholangiopancreatography, 46 by intraoperative cholangiography, and 2 by percutaneous transhepatic cholangiography. RESULTS According to the findings, 16 patients (28%) had CBDS, 6 patients (10%) had common bile duct stenosis, and 36 patients (62%) had a clear bile duct. With regard to CBDS, the short sequence had 100% specificity, 94% sensitivity, and an overall accuracy of 98%. Its negative predictive value was 98%, and its positive predictive value was 100%. The long sequence had a specificity of 100% and a sensitivity of 100%. CONCLUSION Because of its high sensitivity and specifity, MRCP has the potential to be the diagnostic method of choice for CBD evaluation. The short sequence is not suitable for the diagnosis of all CBD pathologies, but in cases of suspected CBDS, more than 80% of the patients could be diagnosed correctly, and the complete sequence could be dropped.
Collapse
Affiliation(s)
- A Shamiyeh
- Ludwig Boltzmann Institute for Operative Laparoscopy, 2nd Surgical Department, Academic Teaching Hospital, Linz, Krankenhausstrasse 9, 4020 Linz, Austria.
| | | | | | | | | |
Collapse
|
21
|
Abstract
In electrochemical sensing devices, aimed for acute and chronic in vivo application, the active surface of the sensor is often negligible compared to the overall surface area of the device in contact with the biological host. Consequently, to minimize the perturbation of an implanted sensor on the in vivo environment the chemical composition and surface texturing of the complete device (the active sensor, sensor substrate, and “accessories”) have to be considered. In our work, the adsorption of three abundant proteins (albumin, IgG, and fibrinogen) was determined quantitatively on untreated and modified sensor substrates and sensing membrane surfaces. In this study, a flexible polyimide-based material (Kapton ®) was used as sensor substrate with or without an amorphous diamond-like carbon (DLC) or an amorphous oxygen-containing DLC (o-DLC) coating. The ion-sensitive membranes were cast from high-molecular-weight (HMW) or carboxylated poly(vinyl chloride) (PVC) and were doped with increasing concentrations of highly hydrophilic poly(ethylene oxide) (PEO). The potentiometric characteristics of the potassium-selective membranes cast with up to 6 % PEO were the same as those without PEO. However, the PEO-modified PVC membranes elicited a large amount of protein adsorption, especially in terms of albumin.
Collapse
Affiliation(s)
- Caroline Lim
- 1Joint Graduate Program in Biomedical Engineering, Department of Biomedical Engineering, The University of Memphis, Memphis, TN 38152, USA; Premitec Inc., Venture II, Suite 101, 920 Main Campus Drive, Raleigh, NC 27606, USA
| | - S. Slack
- 1Joint Graduate Program in Biomedical Engineering, Department of Biomedical Engineering, The University of Memphis, Memphis, TN 38152, USA; Premitec Inc., Venture II, Suite 101, 920 Main Campus Drive, Raleigh, NC 27606, USA
| | - S. Ufer
- 1Joint Graduate Program in Biomedical Engineering, Department of Biomedical Engineering, The University of Memphis, Memphis, TN 38152, USA; Premitec Inc., Venture II, Suite 101, 920 Main Campus Drive, Raleigh, NC 27606, USA
| | - E. Lindner
- 1Joint Graduate Program in Biomedical Engineering, Department of Biomedical Engineering, The University of Memphis, Memphis, TN 38152, USA; Premitec Inc., Venture II, Suite 101, 920 Main Campus Drive, Raleigh, NC 27606, USA
| |
Collapse
|
22
|
Affiliation(s)
- N Bitterlich
- pe Diagnostik GmbH, Leipzig-Markkleeberg, Germany
| | | | | |
Collapse
|
23
|
Pendley BD, Gyurcsányi RE, Buck RP, Lindner E. A chronoamperometric method to estimate changes in the membrane composition of ion-selective membranes. Anal Chem 2001; 73:4599-606. [PMID: 11605836 DOI: 10.1021/ac010007e] [Citation(s) in RCA: 33] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/29/2022]
Abstract
A new chronoamperometric method is used to estimate changes in the membrane composition of mobile-site, ionophore-based membranes. The characteristic features of the chronoamperometric curves (initial current, slope, break time) of valinomycin-based, potassium-selective membranes loaded with potassium tetrakis(4-chlorophenyl)borate are correlated with the mobile-site and free ionophore concentration in the membrane. limiting cases for strong and negligible ion pair formation are distinguished. Replicate measurements indicate a relative standard deviation in the calculated values less than 10%. The practical applicability of the method was tested with membranes incorporated into conventional ion-selective electrode bodies or cast onto microfabricated planar sensor structures.
Collapse
Affiliation(s)
- B D Pendley
- Department of Chemistry, Rhodes College, Memphis, Tennessee 38112, USA
| | | | | | | |
Collapse
|
24
|
Abstract
Minor ion fluxes across ion-selective membranes bias submicromolar activity measurements with conventional ion-selective electrodes. When ion fluxes are balanced, the lower limit of detection is expected to be dramatically improved. As proof of principle, the flux of lead ions across an ETH 5435 ionophore-based lead-selective membrane was gradually compensated by applying a few nanoamperes of galvanostatic current. When the opposite ion fluxes were matched, and the undesirable leaching of primary ions was eliminated, Nernstian response down to 3 x 10(-12) M was achieved.
Collapse
Affiliation(s)
- E Pergel
- Institute of General and Analytical Chemistry, Budapest University of Technology and Economics, Hungary
| | | | | | | |
Collapse
|
25
|
Gyurcsányi RE, Pergel E, Nagy R, Kapui I, Lan BT, Tóth K, Bitter I, Lindner E. Direct Evidence of Ionic Fluxes Across Ion-Selective Membranes: A Scanning Electrochemical Microscopic and Potentiometric Study. Anal Chem 2001; 73:2104-11. [PMID: 11354497 DOI: 10.1021/ac000922k] [Citation(s) in RCA: 105] [Impact Index Per Article: 4.6] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/30/2022]
Abstract
Scanning electrochemical microscopy (SECM) supplemented with potentiometric measurements was used to follow the time-dependent buildup of a steady-state diffusion layer at the aqueous-phase boundary of lead ion-selective electrodes (ISEs). Differential pulse voltammetry is adapted to SECM for probing the local concentration profiles at the sample side of solvent polymeric membranes. Major factors affecting the membrane transport-related surface concentrations were identified from SECM data and the potentiometric transients obtained under different experimental conditions (inner filling solution composition, membrane thickness, surface pretreatment). The amperometrically determined surface concentrations correlated well with the lower detection limits of the lead ion-selective electrodes.
Collapse
Affiliation(s)
- R E Gyurcsányi
- Hungarian Academy of Sciences, Institute of General and Analytical Chemistry, Budapest University of Technology and Economics
| | | | | | | | | | | | | | | |
Collapse
|
26
|
Gyurcsányi RE, Cristalli A, Nagy G, Nagy L, Corder C, Pendley BD, Ufer S, Nagle HT, Neuman MR, Lindner E. Analytical performance characteristics of thin and thick film amperometric microcells. Fresenius J Anal Chem 2001; 369:286-94. [PMID: 11293706 DOI: 10.1007/s002160000614] [Citation(s) in RCA: 14] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 12/01/2022]
Abstract
The analytical performance of amperometric microcells with different electrode geometries is compared for enzyme activity measurements. The microcells were fabricated with thin film photolithography or thick film screen-printing in four different designs. The cells made with the thin film process used flexible substrate with microelectrode array or a circular, disk-shaped working electrode. The screen-printed working electrodes had semicircle or disk shape on ceramic chips. Putrescine oxidase (PUO) activity measurement was used as a model. The determination of PUO activity is important in the clinical diagnosis of premature rupture of the amniotic membrane. An electropolymerized m-phenylenediamine size-exclusion layer was used to eliminate common interferences. The size exclusion layer revealed also to be advantageous in protecting the electrodes from fouling by putrescine (enzyme substrate). The electrode fouling of bare electrodes was insignificant for screen-printed electrodes, but very severe for electroplated platinum working electrodes. The microelectrode array electrodes demonstrated smaller RSD and higher normalized sensitivities for hydrogen peroxide and PUO activity. All the other electrodes were demonstrating comparable analytical performances.
Collapse
Affiliation(s)
- R E Gyurcsányi
- Joint Graduate Program in Biomedical Engineering, The University of Memphis and University of Tennessee Health Science Center, 38152-6582, USA
| | | | | | | | | | | | | | | | | | | |
Collapse
|
27
|
Affiliation(s)
- R P Buck
- University of North Carolina, USA.
| | | |
Collapse
|
28
|
Shamiyeh A, Rieger R, Schrenk P, Lindner E, Wayand W. [Spiral CT cholangiography is not suitable for routine diagnosis before laparoscopic cholecystectomy]. Chirurg 2001; 72:159-63. [PMID: 11253675 DOI: 10.1007/s001040051285] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/27/2022]
Abstract
INTRODUCTION The purpose of this prospective controlled study was to evaluate the diagnostic potential of spiral computed tomographic (CT) cholangiography in patients undergoing laparoscopic cholecystectomy. METHODS 60 patients (17 men, 43 women, mean age 54.5 years, range 15-84 years) with symptomatic cholecystolithiasis were included in this study. After infusion of meglumine jodoxamate, all patients underwent upper abdominal spiral CT. The results of the spiral CT scan were then compared with endoscopic retrograde cholangiography (ERC) or intraoperative cholangiography. RESULTS In 53 patients (88%) CT cholangiography was considered to be technically adequate for interpretation, but was suboptimal in 4 patients (7%) and nondiagnostic in 3 patients (5%), respectively. CT cholangiography showed a stone free common bile duct in 51 patients which was correct in all cases. CT cholangiography predicted a common bile duct stone in 6 patients which proved to be correct in 4 patients but was found to be incorrect in 2 patients. CONCLUSION Spiral CT cholangiography is useful for the diagnosis of common bile duct stones. Because of the low positive predicting value routine use before laparoscopic cholecystectomy is not justified.
Collapse
Affiliation(s)
- A Shamiyeh
- 2. Chirurgische Abteilung und Ludwig Boltzmann Institut für Operative Laparoskopie, Allgemein Offentliches Krankenhaus Linz, Osterreich
| | | | | | | | | |
Collapse
|
29
|
Kallinowski B, Knöll A, Lindner E, Sänger R, Stremmel W, Vollmar J, Zieger B, Jilg W. Can monovalent hepatitis A and B vaccines be replaced by a combined hepatitis A/B vaccine during the primary immunization course? Vaccine 2000; 19:16-22. [PMID: 10924782 DOI: 10.1016/s0264-410x(00)00166-3] [Citation(s) in RCA: 28] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/23/2022]
Abstract
A combined hepatitis A/B vaccine (Twinrix Adult) has been licensed in Germany since 1997. We investigated possible differences in immunogenicity and safety when changing over from vaccinations with monovalent vaccines made by different manufacturers to vaccinations with the combined hepatitis A/B vaccine in an open, randomized, multicenter trial. We therefore compared four different schemes changing over from concomitant vaccinations with monovalent vaccines against hepatitis A and B (Havrix 1440+Engerix-B or Vaqta+Gen H-B-Vax) to combined vaccination against hepatitis A+B with three injections of the combined hepatitis A/B vaccine (0, 1, and 6 month schedule). Local and general symptoms were mostly mild in all five groups. With complete three-dose course using the combined vaccine or an early changeover from monovalent vaccines to the combined vaccine, higher overall anti-HBs seroprotection rates and geometric mean concentrations (GMCs) against hepatitis B could be achieved as early as after 2 months as compared to those groups switching later to the combined vaccine. This study demonstrated for the first time that switching from monovalent hepatitis A and B vaccinations to the combined hepatitis A and B vaccination has no negative influence on the tolerability and improves the immunogenicity.
Collapse
Affiliation(s)
- B Kallinowski
- Department of Internal Medicine IV, University Hospital of Heidelberg, Bergheimer Strasse 58, D-69115, Heidelberg, Germany.
| | | | | | | | | | | | | | | |
Collapse
|
30
|
Nagy G, Gyurcsányi RE, Cristalli CA, Neuman MR, Lindner E. Screen-printed amperometric microcell for proline iminopeptidase enzyme activity assay. Biosens Bioelectron 2000; 15:265-72. [PMID: 11219738 DOI: 10.1016/s0956-5663(00)00081-6] [Citation(s) in RCA: 8] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/18/2022]
Abstract
A microfabricated amperometric microcell was designed and used for the determination of proline iminopeptidase (PIP) enzyme activity in 2-10-microl samples. The measurements were made in the range of 10.3-841.5 mU/ml enzyme activities. The sensitivity of the determinations was between - 0.0195 and - 0.0203 microA ml/mU per min. The coefficient of variation of the determined values ranged between 2.8 (at 561.2 mU/ml) and 24.1% (at 10.3 mU/ml). The microcell was manufactured on an alumina substrate using screen-printed graphite working and Ag/AgCl reference electrodes. Elevated PIP activity in the vaginal fluid is a biochemical indicator of bacterial vaginosis. The method is appropriate to differentiate between normal (66+/-145 mU/ml) and elevated, diseased (704+/-145 mU/ml), values.
Collapse
Affiliation(s)
- G Nagy
- Joint Graduate Program in Biomedical Engineering, The University of Memphis and University of Tennessee Health Science Center, Herff College of Engineering, 38152-6582, USA
| | | | | | | | | |
Collapse
|
31
|
Affiliation(s)
- E Lindner
- Joint Graduate Program of Biomedical Engineering, University of Memphis, TN 38152-6582, USA.
| | | |
Collapse
|
32
|
Weber A, Lindner E, Weltle D, Lehnert G. [Medical habilitation. Accepted academic qualifications or outdated formalism?]. Med Klin (Munich) 2000; 95:235-42. [PMID: 10808309 DOI: 10.1007/pl00002115] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/28/2022]
Abstract
BACKGROUND With the changes in the structure of education and society, in recent years also the medical habilitation (German postdoctoral lecturing qualification) has been called into question as an academic qualification. With this in mind, the aim of our study was to discover the current opinion of those who had successfully completed a habilitation on the prerequisites for a habilitation, the habilitation procedure and the status of a habilitation, and to document potential wishes for reform. COLLECTIVE AND METHODS: The target group of our survey were the 616 persons (female: 77, male 539) who successfully completed their habilitation in 1997 at one of the 36 German medical faculties. The database was formed by an anonymous questionnaire (23 items), which included questions on sociodemographic factors and occupational history (general part), and subjective opinions (specific part). Recruitment of the participants in the survey and passing on of the questionnaire were carried out by the office of the medical dean of the various universities, as the names of those who had completed a habilitation were not available to the investigators for reasons of protecting the individual's rights and identity. Evaluation of the returned questionnaires was carried out using descriptive statistics. Subgroups were formed according to sex, age and subject groups. RESULTS The questionnaire was answered in a useable form by 389 persons (female: 46, male 343) from 35 medical faculties (return quota 63%). 95% of those who took part in the survey were registered doctors; 79% of these came from clinics, 16% from the field of theoretical medicine. 81% were specialist physicians. 5% had studied the natural sciences or humanities. The median age at the time of completing the habilitation was 38 years (minimum 30, maximum 54 years old). At present 93% were assistant professors, 5% were professors. The median interval between the doctoral thesis and habilitation was 10 years. 58% had carried out a period of research abroad. In 90% of cases the persons had written a postdoctoral thesis for their habilitation, 10% qualified cumulatively. 47% had improved their occupational rank within a period of 2 years after completing the habilitation, about 2/3 of these reached senior positions. Among the prerequisites for habilitation, "Humboldt's trias" (research, teaching and caring for patients) was accepted by the great majority. Other prerequisites regarded as important for habilitation were publications, holding talks, specialist status and experience abroad. Impact factors, however, should be regarded as important conditions for habilitation only in combination with other criteria. The value of a habilitation was not called into question; 89% would recommend completing one. 80% of those questioned, however, thought the procedure for completing a habilitation should be optimized. The general abolition of the medical habilitation was, however, not desired by the vast majority. CONCLUSION The value of completing a medical habilitation is not a point for debate for most of those who successfully completed one. It remains the springboard for occupational advancement. The vast majority do not wish to see it abolished. Also the usual prerequisites for habilitation are accepted by the majority of persons. The procedure for completing a habilitation is, however, regarded as in need of improvement. There is a wide consensus of opinion regarding potential aims for reform.
Collapse
Affiliation(s)
- A Weber
- Arbeitsgruppe Sozialmedizin des Instituts, Universität Erlangen-Nürnberg
| | | | | | | |
Collapse
|
33
|
Ellwanger A, Brindle R, Kaiser M, Wielandt W, Lindner E, Albert K. n-Alkyl fluorenyl phases in chromatography. II. Dynamic behavior and high-performance liquid chromatography applications. J Chromatogr A 1999; 858:133-53. [PMID: 10551347 DOI: 10.1016/s0021-9673(99)00828-6] [Citation(s) in RCA: 12] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/18/2022]
Abstract
The dynamic behavior of two n-hexyl fluorenyl phases (fluorene-6A [3a(Tn)(Qm)y], fluorene-6B [3b(Tn)(Qm)y]) and three n-decyl fluorenyl phases (fluorene-10A [4a(Tn)(Qm)y], fluorene-10B [4b(Tn)(Qm)y], and fluorene-10C [4c(M1)(Qm)y]) is investigated by solid-state nuclear magnetic resonance (NMR) spectroscopy using the dipolar filter technique with both 13C and 1H detection. These results are compared with those from other dynamic measurements, like the relaxation times in the rotating frame (T1pH) and the variation of the contact time (T(CH)). Additionally, another type of a fluorenyl phase [5a(Tn)(Qm)y], which has an aromatic moiety connected to the silica gel by amido couplings, was also investigated by the dipolar filter method. The solid-state NMR dynamic measurements indicate an increased mobility of the n-alkyl fluorenyl phases compared to the amido coupled fluorenyl phase. The lower the ligand density of the studied n-alkyl fluorenyl phases, the higher their mobility. The separation behavior of the respective phases in high-performance liquid chromatography was investigated with samples containing polycyclic aromatic hydrocarbons and nitro explosives. Depending on the amount of the chemically bound aromatic moiety and the length of their n-alkyl spacer groups, pi-pi interactions with the solute molecules are involved in the separation process and cause it to proceed at a different rate. Therefore, n-alkyl fluorenyl phases can be classified as mixed-mode phases.
Collapse
Affiliation(s)
- A Ellwanger
- Institut für Organische Chemie, Tübingen, Germany
| | | | | | | | | | | |
Collapse
|
34
|
|
35
|
Abstract
A new class of silica gel-bound fluorene phases is described. The compounds are synthesized via reaction of fluorenyl lithium with omega-alkenyl bromides leading to 9-(5'-hexenyl)-9H- and 9-(9'-decenyl)-9H-fluorene (1 and 2), followed by hydrosilation reactions with different hydrosilanes. The resulting omega-functionalized silylalkyl fluorenes 3a(T0), 3b(T0), 4a(T0), 4b(T0) and 4c(M0) (Scheme 1) react with surface silanol groups of silica gel to generate the new fluorene phases 3a(Tn)(Qm)y, 3b(Tn)(Qm)y, 4a(Tn)(Qm)y, 4b(Tn)(Qm)y and 4c(M1)(Qm)y. The phases are characterized by employing 1H, 13C and 29Si solid-state nuclear magnetic resonance spectroscopy. Their applicability in high-performance liquid chromatography is proved by the Sander and Wise test (SRM 869). In contrast to conventional n-alkyl phases, pi-pi interactions are additionally involved in the separation process and, therefore, the retention times of the polycyclic aromatic hydrocarbons sample molecules depend on the ligand densities of the applied fluorene phases.
Collapse
Affiliation(s)
- W Wielandt
- Institut für Anorganische Chemie, Tübingen, Germany
| | | | | | | |
Collapse
|
36
|
Abstract
The performance of miniaturized potentiometric cells, with multilayer, planar ion-selective sensors in aqueous electrolyte solutions, human serum, urine, and whole blood, is presented. The basic steps of the fabrication with silicon technology are summarized. The effect of the contact surface between the internal reference system and the ion-sensitive membrane on the analytical characteristics of potassium- and calcium-sensitive sensors is studied. Silicone rubber-, high molecular weight PVC-, carboxylated PVC and aliphatic polyurethane (Tecoflex)-based solvent polymeric membranes were dispensed into anisotropically etched wells on silicon wafers, and the resulted planar sensors were tested in terms of their ion sensitivity (slopes of the cell voltage-pK or pCa calibration curves), long-term stability, and reproducibility. For the assay of potassium in whole blood, the miniaturized potentiometric cell was built in a flow-through manifold. To achieve the required precision, the flow conditions were optimized and the sensors calibrated periodically. The results prove the feasibility of the new sensor design and satisfy the particularly difficult requirements for the analysis of biological samples.
Collapse
Affiliation(s)
- A Uhlig
- Fraunhofer Institut für Siliziumtechnologie, Itzehoe, Germany
| | | | | | | | | |
Collapse
|
37
|
Cosofret VV, Erdösy M, Buck RP, Kao WJ, Anderson JM, Lindner E, Neuman MR. Electroanalytical and biocompatibility studies on carboxylated poly(vinyl chloride) membranes for microfabricated array sensors. Analyst 1994; 119:2283-92. [PMID: 7872483 DOI: 10.1039/an9941902283] [Citation(s) in RCA: 32] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/27/2023]
Abstract
Potassium ion-selective and pH membrane electrodes based on neutral carrier ionophores for K+ (valinomycin) and H+ (TDDA and ETH 5294), respectively, immobilized in carboxylated PVC (PVC-COOH) with normal (classical) and reduced amounts of plasticizer, were investigated with respect to their general analytical performances (linear range, slope, detection limit, selectivity, internal membrane resistance), their biocompatibility and cellular responses. The analytical performance of potassium selective electrodes was not affected by reducing the plasticizer content from 66% (m/m) to about 33% (m/m) while that of pH electrodes was significantly changed at the lower plasticizer concentration level. The adhesive properties of PVC-COOH membranes to an inert substrate such as polyimide-coated Kapton are greatly improved by reducing the plasticizer content of the membrane. In addition, as was reported earlier by this group, improved biocompatibility was observed with these membranes relative to those with increased plasticizer content. A ratio of 1:1 m/m for PVC-COOH to plasticizer is recommended for the construction of planar ISEs without massive use of internal solution.
Collapse
Affiliation(s)
- V V Cosofret
- Department of Chemistry, University of North Carolina, Chapel Hill 27599-3290
| | | | | | | | | | | | | |
Collapse
|
38
|
|
39
|
Lindner E, Cosofret VV, Ufer S, Buck RP, Kao WJ, Neuman MR, Anderson JM. Ion-selective membranes with low plasticizer content: electroanalytical characterization and biocompatibility studies. J Biomed Mater Res 1994; 28:591-601. [PMID: 8027099 DOI: 10.1002/jbm.820280509] [Citation(s) in RCA: 75] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 01/28/2023]
Abstract
High molecular weight poly(vinyl chloride) and aliphatic polyurethane (Tecoflex)-based ion selective membranes, with normal and reduced amounts of plasticizer, as well as without plasticizer, were tested with respect to their analytical properties, their biocompatibility, and cellular responses. The analytical properties of the membranes did not change significantly within a wide range of polymer to plasticizer ratios. However, the membranes with reduced plasticizer content had better adhesive properties, less anion interference, extended life time, and better biocompatibility. Using the cage implant system, the results showed that an increase of plasticizer weight percent in Tecoflex membranes correlated positively with the increase in host inflammatory response up to 14 days of implantation. The results also demonstrated that both PVC and Tecoflex-based ion-selective membranes with the most common membrane composition (1:2 polymer to plasticizer ratio) exhibited a similar acute inflammatory response, but the PVC-based membrane elicited a reduced chronic inflammatory response when compared with the Tecoflex-based membrane.
Collapse
Affiliation(s)
- E Lindner
- Department of Chemistry, University of North Carolina at Chapel Hill 27599-3290
| | | | | | | | | | | | | |
Collapse
|
40
|
Kusy RP, Whitley JQ, Buck RP, Cosofret VV, Lindner E. Development of piperazine grafted poly(vinyl chloride)s for fixed site proton carriers. ACTA ACUST UNITED AC 1994. [DOI: 10.1007/bf00273227] [Citation(s) in RCA: 9] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [What about the content of this article? (0)] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/29/2022]
|
41
|
Abstract
The histogenesis of the dorsal root ganglia of chick embryos (ages 3 to 9 days) was followed in three different tissue culture systems. Organotypic explants included dorsal root ganglia connected to the lumbosacral segment of the spinal cord or isolated explants of the contralateral ganglia. Additionally, dissociated monolayer cultures of ganglia tissue were established. The gradual differentiation of progenitor neuroblasts into distinct populations of large ventrolateral and small dorsomedial neurons was observed in vivo and in vitro. Neurites developed after 3 days in the presence or absence of nerve growth factor in the medium. In contrast, autoradiographic analysis indicates that [3H]thymidine incorporation in neuronal cultures differed significantly from intact embryos. In vivo, the number of neuronal progenitor cells labeled with [3H]thymidine decreased in older embryos; in vitro, uptake of [3H]thymidine label was not observed in ganglionic progenitor cells regardless of the age of the donor embryo or the type of culture system. Lack of proliferation in ganglionic progenitor cells was not due to degeneration because vital staining and uptake of [3H]deoxyglucose indicated that neurons were metabolically active. Furthermore, the block in mitotic activity in vitro was limited to presumptive ganglionic neuronal cells. In the ependyma of the spinal cord segment connected to the dorsal root ganglia, neuronal progenitor cells were heavily labeled as were non-neuronal cells within both spinal cord and ganglia. Our results suggest that in vitro conditions can promote the differentiation of sensory neurons from early embryos (E3.5-4.5) without proliferation of progenitor cells.
Collapse
|
42
|
Lindner E, Schreiber R, Kemmler M, Mayer HA, Fawzi R, Steimann M. Tr�gerfixierte Organometallkomplexe. IV. Strukturuntersuchungen an neutralen und kationischen (Ether-phosphan)palladium(II)-Komplexen. Z Anorg Allg Chem 1993. [DOI: 10.1002/zaac.19936190133] [Citation(s) in RCA: 10] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [What about the content of this article? (0)] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/06/2022]
|
43
|
de Klerk-Engels B, Groen J, Vrieze K, Möckel A, Lindner E, Goubitz K. Synthesis of new (cyclopentadienyl)rutheniumphosphine complexes with hemilabile ether-phosphines. The X-ray structure of (η5-C5H5)RuCl(Ph2PCH2CH2OCH3)2. Inorganica Chim Acta 1992. [DOI: 10.1016/s0020-1693(00)85318-9] [Citation(s) in RCA: 21] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [What about the content of this article? (0)] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/17/2022]
|
44
|
Lindner E, Bader A, Mayer HA. Darstellung und Eigenschaften l�slicher und Polysiloxangebundener (Ether-Phosphan)ruthenium(II)-Komplexe. Z Anorg Allg Chem 1991. [DOI: 10.1002/zaac.19915980121] [Citation(s) in RCA: 17] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [What about the content of this article? (0)] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/12/2022]
|
45
|
Lindner E, Niegreisz Z, Toth K, Pungor E, Berube T, Buck R. Electrical and dynamic properties of non-plasticized potassium selective membranes. ACTA ACUST UNITED AC 1989. [DOI: 10.1016/0022-0728(89)80039-7] [Citation(s) in RCA: 46] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [What about the content of this article? (0)] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/30/2022]
|
46
|
Lindner E, Nothdurft A. Darstellung, Eigenschaften sowie Reaktionen metallhaltiger Heterocyclen. LXVI. Nickelinduzierte Cyclocodimerisierung eines Thioxophosphor(V)-Kations mit einem aktivierten Alkin. Z Anorg Allg Chem 1989. [DOI: 10.1002/zaac.19895790123] [Citation(s) in RCA: 9] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [What about the content of this article? (0)] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/05/2022]
|
47
|
Lindner E. [Pain treatment with opiates--a renaissance?]. Fortschr Med 1987; 105:447. [PMID: 2887493] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [MESH Headings] [Subscribe] [Scholar Register] [Indexed: 01/03/2023]
|
48
|
Blottner D, Lindner E. Light-microscopic studies on spatial and temporal binding of the lectins concanavalin A, wheat-germ agglutinin and peanut agglutinin in early rat odontogenesis. Arch Oral Biol 1987; 32:35-42. [PMID: 3479072 DOI: 10.1016/0003-9969(87)90151-8] [Citation(s) in RCA: 8] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/06/2023]
Abstract
The spatial distribution and temporal expression of alpha-D-mannosyl(glucosyl)-, N-acetyl-D-glucosaminyl- and beta-D-galactosyl residues as detected by peroxidase-conjugated lectins correlated with early odontogenic events in six principal developmental stages (fetal days 13.5, 14, 15, 17, 18.5 and 19.5). The odontogenic epithelium of 13.5- and 14-day-old fetuses was characterized by strong concanavalin A (Con A) binding and between days 17 and 19.5, the stellate reticulum displayed strong peanut agglutinin (PNA) binding. Between 15 and 19.5, differentiation of dental ectomesenchyme was characterized by a rhythmic expression of terminal galactosyl residues shown by PNA-binding. At the developing dental basement membrane, there were various carbohydrate-specific regions. At days 13.5 and 14, the odontogenic basement membrane was specific for N-acetyl-D-glucosamines detected by wheat-germ agglutinin (WGA). The results suggest that the carbohydrates present at the inner dental basement membrane at days 17 to 19.5 may be involved in cell-matrix interactions during cytodifferentiation.
Collapse
Affiliation(s)
- D Blottner
- Institute of Anatomy, University of Regensburg, F.R.G
| | | |
Collapse
|
49
|
|
50
|
Schindler JF, de Vries U, Lindner E. Microspectrophotometric and scanning microphotometric studies of carp (Cyprinus carpio L.) erythrocytes. Histochemistry 1985; 82:483-9. [PMID: 3928536 DOI: 10.1007/bf02450484] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [What about the content of this article? (0)] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 01/08/2023]
Abstract
Carp (Cyprinus carpio) hemoglobin readily autoxidizes in blood smears. Quantification of Soret-band absorbance in individual erythrocytes by means of scanning cytophotometry therefore requires more elaborate methods of preparation of blood samples. Of the fixatives that have been tested, suspension of whole blood in isotonic salt solutions containing glutaraldehyde was most suitable. Glutaraldehyde-fixed red blood cells are totally resistant to hemolysis. In the course of fixation, hemoglobin is transformed to methemoglobin. Spectrophotometry indicated extensive similarities between glutaraldehyde-fixed carp methemoglobin and human methemoglobin. In aqueous solutions, the intensity of the Soret-peak was pH-dependent. The allosteric modifier organic polyphosphate caused an R----T transition, resulting in increased molar extinctions. Dried preparations showed Soret-spectra that were not influenced from either pH or organic polyphosphate concentration of the aqueous suspensions in which the erythrocytes had been stored. The same was true for slide preparations of cyanomethemoglobin, easily derived from methemoglobin on addition of potassium cyanide. In the absence of oxygen fresh blood cells from carp slowly transform their hemoglobin into deoxyhemoglobin. Spectra of the intermediate stages of deoxygenation, Hb4(O2)3, Hb4(O2)2 and Hb4(O2), as well as mixtures of these intermediates, could be monitored.
Collapse
|