1
|
Roberts CT, Beck SK, Prejean CM, Graul LM, Maitland DJ, Grunlan MA. Star-PCL shape memory polymer (SMP) scaffolds with tunable transition temperatures for enhanced utility. J Mater Chem B 2024; 12:3694-3702. [PMID: 38529581 PMCID: PMC11022546 DOI: 10.1039/d4tb00050a] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/08/2024] [Accepted: 03/13/2024] [Indexed: 03/27/2024]
Abstract
Thermoresponsive shape memory polymers (SMPs) prepared from UV-curable poly(ε-caprolactone) (PCL) macromers have the potential to create self-fitting bone scaffolds, self-expanding vaginal stents, and other shape-shifting devices. To ensure tissue safety during deployment, the shape actuation temperature (i.e., the melt transition temperature or Tm of PCL) must be reduced from ∼55 °C that is observed for scaffolds prepared from linear-PCL-DA (Mn ∼ 10 kg mol-1). Moreover, increasing the rate of biodegradation would be advantageous, facilitating bone tissue healing and potentially eliminating the need for stent retrieval. Herein, a series of six UV-curable PCL macromers were prepared with linear or 4-arm star architectures and with Mns of 10, 7.5, and 5 kg mol-1, and subsequently fabricated into six porous scaffold compositions (10k, 7.5k, 5k, 10k★, 7.5k★, and 5k★) via solvent casting particulate leaching (SCPL). Scaffolds produced from star-PCL-tetraacrylate (star-PCL-TA) macromers produced pronounced reductions in Tm with decreased Mnversus those formed with the corresponding linear-PCL-diacrylate (linear-PCL-DA) macromers. Scaffolds were produced with the desired reduced Tm profiles: 37 °C < Tm < 55 °C (self-fitting bone scaffold), and Tm ≤ 37 °C (self-expanding stent). As macromer Mn decreased, crosslink density increased while % crystallinity decreased, particularly for scaffolds prepared from star-PCL-TA macromers. While shape memory behavior was retained and radial expansion pressure increased, this imparted a reduction in modulus but with an increase in the rate of degradation.
Collapse
Affiliation(s)
- Courteney T Roberts
- Department of Biomedical Engineering, Texas A&M University, College Station, Texas 77843, USA.
| | - Sarah K Beck
- Department of Biomedical Engineering, Texas A&M University, College Station, Texas 77843, USA.
| | - C Mabel Prejean
- Department of Biomedical Engineering, Texas A&M University, College Station, Texas 77843, USA.
| | - Lance M Graul
- Department of Biomedical Engineering, Texas A&M University, College Station, Texas 77843, USA.
| | - Duncan J Maitland
- Department of Biomedical Engineering, Texas A&M University, College Station, Texas 77843, USA.
| | - Melissa A Grunlan
- Department of Biomedical Engineering, Texas A&M University, College Station, Texas 77843, USA.
- Department of Materials Science and Engineering, Texas A&M University, College Station, Texas 77843, USA
- Department of Chemistry, Texas A&M University, College Station, Texas 77843, USA
| |
Collapse
|
2
|
Nitschke BM, Beltran FO, Hahn MS, Grunlan MA. Trends in bioactivity: inducing and detecting mineralization of regenerative polymeric scaffolds. J Mater Chem B 2024; 12:2720-2736. [PMID: 38410921 PMCID: PMC10935659 DOI: 10.1039/d3tb02674d] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/10/2023] [Accepted: 02/14/2024] [Indexed: 02/28/2024]
Abstract
Due to limitations of biological and alloplastic grafts, regenerative engineering has emerged as a promising alternative to treat bone defects. Bioactive polymeric scaffolds are an integral part of such an approach. Bioactivity importantly induces hydroxyapatite mineralization that promotes osteoinductivity and osseointegration with surrounding bone tissue. Strategies to confer bioactivity to polymeric scaffolds utilize bioceramic fillers, coatings and surface treatments, and additives. These approaches can also favorably impact mechanical and degradation properties. A variety of fabrication methods are utilized to prepare scaffolds with requisite morphological features. The bioactivity of scaffolds may be evaluated with a broad set of techniques, including in vitro (acellular and cellular) and in vivo methods. Herein, we highlight contemporary and emerging approaches to prepare and assess scaffold bioactivity, as well as existing challenges.
Collapse
Affiliation(s)
- Brandon M Nitschke
- Department of Biomedical Engineering, Texas A&M University, College Station, TX 77843, USA.
| | - Felipe O Beltran
- Department of Materials Science & Engineering, Texas A&M University, College Station, TX 77843, USA
| | - Mariah S Hahn
- Department of Biomedical Engineering, Rensselaer Polytechnic Institute, Troy, NY 12180, USA
| | - Melissa A Grunlan
- Department of Biomedical Engineering, Texas A&M University, College Station, TX 77843, USA.
- Department of Materials Science & Engineering, Texas A&M University, College Station, TX 77843, USA
- Department of Chemistry, Texas A&M University, College Station, TX 77843, USA
| |
Collapse
|
3
|
Ganabady K, Contessi Negrini N, Scherba JC, Nitschke BM, Alexander MR, Vining KH, Grunlan MA, Mooney DJ, Celiz AD. High-Throughput Screening of Thiol-ene Click Chemistries for Bone Adhesive Polymers. ACS Appl Mater Interfaces 2023; 15:50908-50915. [PMID: 37905511 PMCID: PMC10636719 DOI: 10.1021/acsami.3c12072] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 08/14/2023] [Revised: 10/13/2023] [Accepted: 10/18/2023] [Indexed: 11/02/2023]
Abstract
Metal surgical pins and screws are employed in millions of orthopedic surgical procedures every year worldwide, but their usability is limited in the case of complex, comminuted fractures or in surgeries on smaller bones. Therefore, replacing such implants with a bone adhesive material has long been considered an attractive option. However, synthesizing a biocompatible bone adhesive with a high bond strength that is simple to apply presents many challenges. To rapidly identify candidate polymers for a biocompatible bone adhesive, we employed a high-throughput screening strategy to assess human mesenchymal stromal cell (hMSC) adhesion toward a library of polymers synthesized via thiol-ene click chemistry. We chose thiol-ene click chemistry because multifunctional monomers can be rapidly cured via ultraviolet (UV) light while minimizing residual monomer, and it provides a scalable manufacturing process for candidate polymers identified from a high-throughput screen. This screening methodology identified a copolymer (1-S2-FT01) composed of the monomers 1,3,5-triallyl-1,3,5-triazine-2,4,6(1H,3H,5H)-trione (TATATO) and pentaerythritol tetrakis (3-mercaptopropionate) (PETMP), which supported highest hMSC adhesion across a library of 90 polymers. The identified copolymer (1-S2-FT01) exhibited favorable compressive and tensile properties compared to existing commercial bone adhesives and adhered to bone with adhesion strengths similar to commercially available bone glues such as Histoacryl. Furthermore, this cytocompatible polymer supported osteogenic differentiation of hMSCs and could adhere 3D porous polymer scaffolds to the bone tissue, making this polymer an ideal candidate as an alternative bone adhesive with broad utility in orthopedic surgery.
Collapse
Affiliation(s)
- Kavya Ganabady
- Department
of Bioengineering, Imperial College London, London W12 0BZ, U.K.
| | | | - Jacob C. Scherba
- Wyss
Institute for Biologically Inspired Engineering and Harvard John A.
Paulson School of Engineering and Applied Sciences, Harvard University, Cambridge, Massachusetts 02138, United States
| | - Brandon M. Nitschke
- Department
of Biomedical Engineering, Texas A&M
University, College
Station, Texas 77843-3120, United States
| | | | - Kyle H. Vining
- School
of Dental Medicine and Department of Materials Science, School of
Engineering and Applied Science, University
of Pennsylvania, Philadelphia, Pennsylvania 19104-6030, United States
| | - Melissa A. Grunlan
- Department
of Biomedical Engineering, Texas A&M
University, College
Station, Texas 77843-3120, United States
| | - David J. Mooney
- Wyss
Institute for Biologically Inspired Engineering and Harvard John A.
Paulson School of Engineering and Applied Sciences, Harvard University, Cambridge, Massachusetts 02138, United States
| | - Adam D. Celiz
- Department
of Bioengineering, Imperial College London, London W12 0BZ, U.K.
- Francis
Crick Institute, London NW1 1AT, U.K.
| |
Collapse
|
4
|
Demott C, Jones MR, Chesney CD, Grunlan MA. Adhesive Hydrogel Building Blocks to Reconstruct Complex Cartilage Tissues. ACS Biomater Sci Eng 2023; 9:1952-1960. [PMID: 36881710 PMCID: PMC10848198 DOI: 10.1021/acsbiomaterials.2c01438] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/02/2022] [Accepted: 02/14/2023] [Indexed: 03/09/2023]
Abstract
Cartilage has an intrinsically low healing capacity, thereby requiring surgical intervention. However, limitations of biological grafting and existing synthetic replacements have prompted the need to produce cartilage-mimetic substitutes. Cartilage tissues perform critical functions that include load bearing and weight distribution, as well as articulation. These are characterized by a range of high moduli (≥1 MPa) as well as high hydration (60-80%). Additionally, cartilage tissues display spatial heterogeneity, resulting in regional differences in stiffness that are paramount to biomechanical performance. Thus, cartilage substitutes would ideally recapitulate both local and regional properties. Toward this goal, triple network (TN) hydrogels were prepared with cartilage-like hydration and moduli as well as adhesivity to one another. TNs were formed with either an anionic or cationic 3rd network, resulting in adhesion upon contact due to electrostatic attractive forces. With the increased concentration of the 3rd network, robust adhesivity was achieved as characterized by shear strengths of ∼80 kPa. The utility of TN hydrogels to form cartilage-like constructs was exemplified in the case of an intervertebral disc (IVD) having two discrete but connected zones. Overall, these adhesive TN hydrogels represent a potential strategy to prepare cartilage substitutes with native-like regional properties.
Collapse
Affiliation(s)
- Connor
J. Demott
- Department
of Biomedical Engineering, Texas A&M
University, College
Station, Texas 77843-3003, United States
| | - McKenzie R. Jones
- Department
of Biomedical Engineering, Texas A&M
University, College
Station, Texas 77843-3003, United States
| | - Caleb D. Chesney
- Department
of Biomedical Engineering, Texas A&M
University, College
Station, Texas 77843-3003, United States
| | - Melissa A. Grunlan
- Department
of Biomedical Engineering, Texas A&M
University, College
Station, Texas 77843-3003, United States
- Department
of Materials Science & Engineering, Texas A&M University, College
Station, Texas 77843-3003, United States
- Department
of Chemistry, Texas A&M University, College Station, Texas 77843-3003, United States
| |
Collapse
|
5
|
Marmo AC, Grunlan MA. Biomedical Silicones: Leveraging Additive Strategies to Propel Modern Utility. ACS Macro Lett 2023; 12:172-182. [PMID: 36669481 PMCID: PMC10848296 DOI: 10.1021/acsmacrolett.2c00701] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/30/2022] [Accepted: 01/18/2023] [Indexed: 01/21/2023]
Abstract
Silicones have a long history of use in biomedical devices, with unique properties stemming from the siloxane (Si-O-Si) backbone that feature a high degree of flexibility and chemical stability. However, surface, rheological, mechanical, and electrical properties of silicones can limit their utility. Successful modification of silicones to address these limitations could lead to superior and new biomedical devices. Toward improving such properties, recent additive strategies have been leveraged to modify biomedical silicones and are highlighted herein.
Collapse
Affiliation(s)
- Alec C. Marmo
- Department
of Materials Science and Engineering Texas
A&M University, College
Station, Texas 77843-3003, United States
| | - Melissa A. Grunlan
- Department
of Biomedical Engineering, Department of Materials Science and Engineering,
Department of Chemistry Texas A&M University, College Station, Texas 77843-3003, United
States
| |
Collapse
|
6
|
Marmo AC, Lott LR, Pickett JH, Koller HE, Nitschke BM, Grunlan MA. Amphiphilic silicones for the facile dispersion of carbon nanotubes and formation of soft skin electrodes. ACS Appl Polym Mater 2023; 5:775-783. [PMID: 37033151 PMCID: PMC10078240 DOI: 10.1021/acsapm.2c01757] [Citation(s) in RCA: 1] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/19/2023]
Abstract
Flexible, dry skin electrodes represent a potentially superior alternative to standard Ag/AgCl metal electrodes for wearable devices used in long-term monitoring. Herein, such electrodes were formed using a facile method for dispersing carbon nanotubes (CNTs) in a silicone matrix using custom amphiphilic dispersive additives (DSPAs). Using only brief mixing and without the use of solvents or surface modification of CNTs, twelve poly(ethylene oxide)-silanes (PEO-SAs) of varying crosslinkability, architecture, siloxane tether length, and molar ratio of siloxane:PEO were combined with an addition cure silicone and CNTs. Nearly all PEO-SA modified silicone-CNT composites demonstrated improved conductivity compared to the unmodified composite. Best conductivities correlated to composites prepared with PEO-SAs that formed micelles of particular sizes (d ~ 200 - 300 nm) and coincided to PEO-SAs with a siloxane:PEO molar ratio of ~ 0.75 - 3.00. Superior dispersion of CNT by such PEO-SAs was exemplified by scanning electron microscopy (SEM). Advantageously, modified composites retained their moduli, rather than becoming more rigid. Resultant electrodes fabricated with modified composites showed skin-electrode impedance comparable to that of Ag/AgCl electrodes. Combined, these results demonstrate the potential of silicone-CNT composites prepared with PEO-SA DSPAs as flexible, dry electrodes as a superior alternative to traditional electrodes.
Collapse
Affiliation(s)
- Alec C Marmo
- Department of Materials Science and Engineering Texas A&M University, College Station, TX 77843-3003 (USA)
| | - Lucas R Lott
- Department of Biomedical Engineering Texas A&M University, College Station, TX 77843-3003 (USA)
| | - Jackson H Pickett
- Department of Biomedical Engineering Texas A&M University, College Station, TX 77843-3003 (USA)
| | - Harrison E Koller
- Department of Chemistry Texas A&M University, College Station, TX 77843-3003 (USA)
| | - Brandon M Nitschke
- Department of Biomedical Engineering Texas A&M University, College Station, TX 77843-3003 (USA)
| | - Melissa A Grunlan
- Department of Biomedical Engineering, Department of Materials Science and Engineering, Department of Chemistry Texas A&M University, College Station, TX 77843-3003 (USA)
| |
Collapse
|
7
|
Demott CJ, Grunlan MA. Emerging polymeric material strategies for cartilage repair. J Mater Chem B 2022; 10:9578-9589. [PMID: 36373438 DOI: 10.1039/d2tb02005j] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/16/2022]
Abstract
Cartilage is found throughout the body, serving an array of essential functions. Owing to the limited healing capacity of cartilage, damage or degeneration is often permanent and so requires clinical intervention. Established surgical techniques generally rely on biological grafting. However, recent advances in polymeric materials provide an encouraging alternative to overcome limits of auto- and allografts. For regenerative engineering of cartilage, a polymeric scaffold ideally supports and instructs tissue regeneration while also providing mechanical integrity. Scaffolds direct regeneration via chemical and mechanical cues, as well as delivery and support of exogenous cells and bioactive factors. Advanced polymeric scaffolds aim to direct regeneration locally, replicating the heterogeneities of native tissues. Alternatively, new cartilage-mimetic hydrogels have potential to serve as synthetic cartilage replacements. Prepared as multi-network or composite hydrogels, the most promising candidates have simultaneously realized the hydration, mechanical, and tribological properties of native cartilage. Collectively, the recent rise in polymers for cartilage regeneration and replacement proposes a changing paradigm, with a new generation of materials paving the way for improved clinical outcomes.
Collapse
Affiliation(s)
- Connor J Demott
- Department of Biomedical Engineering, Texas A&M University, College Station, TX 77843-3003, USA
| | - Melissa A Grunlan
- Department of Biomedical Engineering, Texas A&M University, College Station, TX 77843-3003, USA.,Department of Materials Science & Engineering, Texas A&M University, College Station, TX 77843-3003, USA.,Department of Chemistry, Texas A&M University, College Station, TX 77843-3003, USA.
| |
Collapse
|
8
|
Demott CJ, Jones MR, Chesney CD, Yeisley DJ, Culibrk RA, Hahn MS, Grunlan MA. Ultra-High Modulus Hydrogels Mimicking Cartilage of the Human Body. Macromol Biosci 2022; 22:e2200283. [PMID: 36040017 DOI: 10.1002/mabi.202200283] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/08/2022] [Revised: 08/12/2022] [Indexed: 12/25/2022]
Abstract
The human body is comprised of numerous types of cartilage with a range of high moduli, despite their high hydration. Owing to the limitations of cartilage tissue healing and biological grafting procedures, synthetic replacements have emerged but are limited by poorly matched moduli. While conventional hydrogels can achieve similar hydration to cartilage tissues, their moduli are substantially inferior. Herein, triple network (TN) hydrogels are prepared to synergistically leverage intra-network electrostatic repulsive and hydrophobic interactions, as well as inter-network electrostatic attractive interactions. They are comprised of an anionic 1st network, a neutral 2nd network (capable of hydrophobic associations), and a cationic 3rd network. Collectively, these interactions act synergistically as effective, yet dynamic crosslinks. By tuning the concentration of the cationic 3rd network, these TN hydrogels achieve high moduli of ≈1.5 to ≈3.5 MPa without diminishing cartilage-like water contents (≈80%), strengths, or toughness values. This unprecedented combination of properties poises these TN hydrogels as cartilage substitutes in applications spanning articulating joints, intervertebral discs (IVDs), trachea, and temporomandibular joint disc (TMJ).
Collapse
Affiliation(s)
- Connor J Demott
- Department of Biomedical Engineering, Texas A&M University, College Station, TX, 77843-3003, USA
| | - McKenzie R Jones
- Department of Biomedical Engineering, Texas A&M University, College Station, TX, 77843-3003, USA
| | - Caleb D Chesney
- Department of Biomedical Engineering, Texas A&M University, College Station, TX, 77843-3003, USA
| | - Daniel J Yeisley
- Department of Biomedical Engineering, Rensselaer Polytechnic Institute, Troy, NY, 12180-3590, USA
| | - Robert A Culibrk
- Department of Biomedical Engineering, Rensselaer Polytechnic Institute, Troy, NY, 12180-3590, USA
| | - Mariah S Hahn
- Department of Biomedical Engineering, Rensselaer Polytechnic Institute, Troy, NY, 12180-3590, USA
| | - Melissa A Grunlan
- Department of Biomedical Engineering, Department of Materials Science & Engineering, and Department of Chemistry, Texas A&M University, College Station, TX, 77843-3003, USA
| |
Collapse
|
9
|
Marmo AC, Rodriguez Cruz JJ, Pickett JH, Lott LR, Theibert DS, Chandler HL, Grunlan MA. Amphiphilic silicones to mitigate lens epithelial cell growth on intraocular lenses. J Mater Chem B 2022; 10:3064-3072. [PMID: 35332909 DOI: 10.1039/d2tb00213b] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/21/2022]
Abstract
Silicone intraocular lenses (IOLs) that resist lens epithelial cell (LEC) growth would greatly improve patient outcomes. Herein, amphiphilic surface modifying additives (SMAs) were incorporated into an IOL-type diphenyl silicone to reduce LEC growth without compromising opto-mechanical properties. The SMAs were poly(ethylene oxide)-silane amphiphiles (PEO-SAs) [H-Si-ODMSm-block-PEO8-OCH3], comprised of a PEO segment and siloxane tether of varying lengths (m = 0, 13, and 30). These three SMAs were each blended into the addition cure diphenyl silicone at varying concentrations (5, 10, 15, 20, and 25 μmol g-1) wherein the wt% of PEO was maintained for all SMAs at a given molar concentration. The chemical crosslinking and subsequent retention of SMAs in modified silicones was confirmed. Key material properties were assessed following equilibration in both air and aqueous environments. Silicones modified with SMAs having longer tethers (m = 13 and 30) underwent rapid and substantial water-driven restructuring of PEO to the surface to form highly hydrophilic surfaces, especially as SMA concentration increased. The % transmittance was also maintained for silicones modified with these particular SMAs. The moduli of the modified silicones were largely unchanged by the SMA and remained in the typical range for silicone IOLs. When the three SMAs were introduced at the highest concentration, modified silicones remained non-cytotoxic and LEC count and associated alpha-smooth muscle actin (α-SMA) expression decreased with increasing tether length. These results demonstrate the potential of silicones modified with PEO-SA SMAs to produce LEC-resistant IOLs.
Collapse
Affiliation(s)
- Alec C Marmo
- Department of Materials Science and Engineering, Texas A&M University, College Station, TX 77843, USA.
| | - J Jesus Rodriguez Cruz
- Department of Biomedical Engineering, Texas A&M University, College Station, TX 77843, USA
| | - Jackson H Pickett
- Department of Biomedical Engineering, Texas A&M University, College Station, TX 77843, USA
| | - Lucas R Lott
- Department of Biomedical Engineering, Texas A&M University, College Station, TX 77843, USA
| | - Dustin S Theibert
- College of Optometry, The Ohio State University, Columbus, OH 43210, USA
| | - Heather L Chandler
- College of Optometry, The Ohio State University, Columbus, OH 43210, USA
| | - Melissa A Grunlan
- Department of Materials Science and Engineering, Texas A&M University, College Station, TX 77843, USA. .,Department of Biomedical Engineering, Texas A&M University, College Station, TX 77843, USA.,Department of Chemistry, Texas A&M University, College Station, TX 77843, USA
| |
Collapse
|
10
|
Stukel Shah JM, Lundquist B, Macaitis J, Pfau-Cloud MR, Beltran FO, Grunlan MA, Lien W, Wang HC, Burdette AJ. Comparative evaluation of mesenchymal stromal cell growth and osteogenic differentiation on a shape memory polymer scaffold. J Biomed Mater Res B Appl Biomater 2022; 110:2063-2074. [PMID: 35344262 DOI: 10.1002/jbm.b.35061] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/18/2021] [Revised: 03/08/2022] [Accepted: 03/12/2022] [Indexed: 11/06/2022]
Abstract
Trauma-induced, critical-size bone defects pose a clinical challenge to heal. Albeit autografts are the standard-of-care, they are limited by their inability to be shaped to various defect geometries and often incur donor site complications. Herein, the combination of a "self-fitting" shape memory polymer (SMP) scaffold and seeded mesenchymal stromal cells (MSCs) was investigated as an alternative. The porous SMP scaffold, prepared from poly(ε-caprolactone) diacrylate (PCL-DA) and coated with polydopamine, provided conformal shaping and cell adhesion. MSCs from five tissues, amniotic (AMSCs), chorionic tissue (CHSCs), umbilical cord (UCSCs), adipose (ADSCs), and bone marrow (BMSCs) were evaluated for viability, density, and osteogenic differentiation on the SMP scaffold. BMSCs exhibited the fastest increase in cell density by day 3, but after day 10, CHSCs, UCSCs, and ADSCs approached similar cell density. BMSCs also showed the greatest calcification among the cell types, followed closely by ADSCs, CHSCs and AMSCs. Alkaline phosphatase (ALP) activity peaked at day 7 for AMSCs, UCSCs, ADSCs and BMSCs, and at day 14 for CHSCs, which had the greatest overall ALP activity. Of all the cell types, only scaffolds cultured with ADSCs in osteogenic media had increased hardness and local modulus as compared to blank scaffolds after 21 days of cell culture and osteogenic differentiation. Overall, ADSCs performed most favorably on the SMP scaffold. The SMP scaffold was able to support key cellular behaviors of MSCs and could potentially be a viable, regenerative alternative to autograft.
Collapse
Affiliation(s)
- Jessica M Stukel Shah
- Directorate of Combat Casualty Care & Operational Medicine, Naval Medical Research Unit San Antonio, San Antonio, Texas, USA
| | - Bridney Lundquist
- Directorate of Combat Casualty Care & Operational Medicine, Naval Medical Research Unit San Antonio, San Antonio, Texas, USA
| | - Joseph Macaitis
- Directorate of Combat Casualty Care & Operational Medicine, Naval Medical Research Unit San Antonio, San Antonio, Texas, USA
| | - Michaela R Pfau-Cloud
- Department of Biomedical Engineering, Texas A&M University, College Station, Texas, USA
| | - Felipe O Beltran
- Department of Materials Science and Engineering, Texas A&M University, College Station, Texas, USA
| | - Melissa A Grunlan
- Department of Biomedical Engineering, Texas A&M University, College Station, Texas, USA.,Department of Materials Science and Engineering, Texas A&M University, College Station, Texas, USA.,Department of Chemistry, Texas A&M University, College Station, Texas, USA
| | - Wen Lien
- USAF Dental Research & Consultation Service, JBSA Fort Sam Houston, San Antonio, Texas, USA
| | - Heuy-Ching Wang
- Directorate of Combat Casualty Care & Operational Medicine, Naval Medical Research Unit San Antonio, San Antonio, Texas, USA
| | - Alexander J Burdette
- Directorate of Combat Casualty Care & Operational Medicine, Naval Medical Research Unit San Antonio, San Antonio, Texas, USA
| |
Collapse
|
11
|
Dong P, Ko BS, Lomeli KA, Clark EC, McShane MJ, Grunlan MA. A Glucose Biosensor Based on a Phosphorescence Lifetime Sensing and a Thermoresponsive Membrane. Macromol Rapid Commun 2022; 43:e2100902. [DOI: 10.1002/marc.202100902] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/21/2021] [Revised: 02/17/2022] [Indexed: 11/11/2022]
Affiliation(s)
- Ping Dong
- Department of Biomedical Engineering Texas A&M University College Station TX 77843‐3120 USA
| | - Brian S. Ko
- Department of Biomedical Engineering Texas A&M University College Station TX 77843‐3120 USA
| | - Kayllie A. Lomeli
- Department of Biomedical Engineering Texas A&M University College Station TX 77843‐3120 USA
| | - Emily C. Clark
- Department of Biomedical Engineering Texas A&M University College Station TX 77843‐3120 USA
| | - Michael J. McShane
- Department of Biomedical Engineering Department of Materials Science & Engineering and Center for Remote Health Technologies Systems Texas A&M University College Station TX 77843‐3003 USA
| | - Melissa A. Grunlan
- Department of Biomedical Engineering Department of Materials Science & Engineering Department of Chemizstry and Center for Remote Health Technologies Systems Texas A&M University College Station TX 77843‐3003 USA
| |
Collapse
|
12
|
Dong P, Singh KA, Soltes AM, Ko BS, Gaharwar AK, McShane MJ, Grunlan MA. Silicone-containing thermoresponsive membranes to form an optical glucose biosensor. J Mater Chem B 2022; 10:6118-6132. [DOI: 10.1039/d2tb01192a] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/21/2022]
Abstract
Glucose biosensors that could be subcutaneously injected and interrogated without a physically connected electrode and transmitter affixed to skin would represent a major advancement in reducing the user burden of...
Collapse
|
13
|
Pfau MR, Beltran FO, Woodard LN, Dobson LK, Gasson SB, Robbins AB, Lawson ZT, Brian Saunders W, Moreno MR, Grunlan MA. Evaluation of a self-fitting, shape memory polymer scaffold in a rabbit calvarial defect model. Acta Biomater 2021; 136:233-242. [PMID: 34571270 PMCID: PMC8742656 DOI: 10.1016/j.actbio.2021.09.041] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/08/2021] [Revised: 09/08/2021] [Accepted: 09/21/2021] [Indexed: 12/20/2022]
Abstract
Self-fitting scaffolds prepared from biodegradable poly(ε-caprolactone)-diacrylate (PCL-DA) have been developed for the treatment of craniomaxillofacial (CMF) bone defects. As a thermoresponsive shape memory polymer (SMP), with the mere exposure to warm saline, these porous scaffolds achieve a conformal fit in defects. This behavior was expected to be advantageous to osseointegration and thus bone healing. Herein, for an initial assessment of their regenerative potential, a pilot in vivo study was performed using a rabbit calvarial defect model. Exogenous growth factors and cells were excluded from the scaffolds. Key scaffold material properties were confirmed to be maintained following gamma sterilization. To assess scaffold integration and neotissue infiltration along the defect perimeter, non-critically sized (d = 8 mm) bilateral calvarial defects were created in 12 New Zealand white rabbits. Bone formation was assessed at 4 and 16 weeks using histological analysis and micro-CT, comparing defects treated with an SMP scaffold (d = 9 mm x t = 1 or 2 mm) to untreated defects (i.e. defects able to heal without intervention). To further assess osseointegration, push-out tests were performed at 16 weeks and compared to defects treated with poly(ether ether ketone) (PEEK) discs (d = 8.5 mm x t = 2 mm). The results of this study confirmed that the SMP scaffolds were biocompatible and highly conducive to bone formation and ingrowth at the perimeter. Ultimately, this resulted in similar bone volume and surface area versus untreated defects and superior performance in push-out testing versus defects treated with PEEK discs. STATEMENT OF SIGNIFICANCE: Current treatments of craniomaxillofacial (CMF) bone defects include biologic and synthetic grafts but they are limited in their ability to form good contact with adjacent tissue. A regenerative engineering approach using a biologic-free scaffold able to achieve conformal fitting represents a potential "off-the-shelf" surgical product to heal CMF bone defects. Having not yet been evaluated in vivo, this study provided the preliminary assessment of the bone healing potential of self-fitting PCL scaffolds using a rabbit calvarial defect model. The study was designed to assess scaffold biocompatibility as well as bone formation and ingrowth using histology, micro-CT, and biomechanical push-out tests. The favorable results provide a basis to pursue establishing self-fitting scaffolds as a treatment option for CMF defects.
Collapse
Affiliation(s)
- Michaela R Pfau
- Department of Biomedical Engineering, Texas A&M University, College Station, Texas 77843, US
| | - Felipe O Beltran
- Department of Materials Science and Engineering, Texas A&M University, College Station, Texas 77843, US
| | - Lindsay N Woodard
- Department of Biomedical Engineering, Texas A&M University, College Station, Texas 77843, US
| | - Lauren K Dobson
- Department of Small Animal Clinical Sciences, Texas A&M University, College Station, Texas 77843, US
| | - Shelby B Gasson
- Department of Small Animal Clinical Sciences, Texas A&M University, College Station, Texas 77843, US
| | - Andrew B Robbins
- Department of Mechanical Engineering, Texas A&M University, College Station, Texas 77843, US
| | - Zachary T Lawson
- Department of Biomedical Engineering, Texas A&M University, College Station, Texas 77843, US
| | - W Brian Saunders
- Department of Small Animal Clinical Sciences, Texas A&M University, College Station, Texas 77843, US
| | - Michael R Moreno
- Department of Biomedical Engineering, Texas A&M University, College Station, Texas 77843, US; Department of Mechanical Engineering, Texas A&M University, College Station, Texas 77843, US
| | - Melissa A Grunlan
- Department of Biomedical Engineering, Texas A&M University, College Station, Texas 77843, US; Department of Materials Science and Engineering, Texas A&M University, College Station, Texas 77843, US; Department of Chemistry, Texas A&M University, College Station, Texas 77843, US.
| |
Collapse
|
14
|
Abstract
Irregularly shaped craniomaxillofacial (CMF) defects may be advantageously treated by "self-fitting" shape memory polymer (SMP) scaffolds, namely those prepared from poly(ε-caprolactone)diacrylate (PCL-DA) networks and PCL-DA/poly(L-lactic acid) (PLLA) (75:25 wt%) semi-interpenetrating polymer networks (semi-IPNs). In addition to achieving good scaffold-tissue contact, a polydopamine (PD) coating can be leveraged to enhance bioactivity for improved osseointegration. Sterilization with ethylene oxide (EtO) represents a logical choice due to its low operating temperature and humidity. Herein, for the first time, the impact of EtO sterilization on the material properties of PD-coated SMP scaffolds was systematically assessed. Morphological features (i.e., pore size and pore interconnectivity), and in vitro bioactivity were preserved as were PCL crystallinity, PLLA crystallinity, and crosslinking. These latter features led to sustained shape memory properties, and compressive modulus. EtO-sterilized, PD-coated scaffolds displayed similar in vitro degradation behaviors versus analogous non-sterilized scaffolds. This included maintenance of compression modulus following 28 days of exposure to non-accelerated degradation conditions.
Collapse
Affiliation(s)
- Christopher J Houk
- Department of Biomedical Engineering, Texas A&M University, College Station, Texas 77843, United States
| | - Felipe O Beltran
- Department of Materials Science & Engineering, Texas A&M University, College Station, Texas 77843, United States
| | - Melissa A Grunlan
- Department of Biomedical Engineering, Texas A&M University, College Station, Texas 77843, United States.,Department of Materials Science & Engineering, Texas A&M University, College Station, Texas 77843, United States.,Department of Chemistry, Texas A&M University, College Station, Texas 77843, United States
| |
Collapse
|
15
|
Lawson ZT, Han J, Saunders WB, Grunlan MA, Moreno MR, Robbins AB. Methodology for performing biomechanical push-out tests for evaluating the osseointegration of calvarial defect repair in small animal models. MethodsX 2021; 8:101541. [PMID: 34754809 PMCID: PMC8563681 DOI: 10.1016/j.mex.2021.101541] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/09/2021] [Accepted: 10/07/2021] [Indexed: 11/03/2022] Open
Abstract
Push-out tests are frequently used to evaluate the bone-implant interfacial strength of orthopedic implants, particularly dental and craniomaxillofacial applications. There currently is no standard method for performing push-out tests on calvarial models, leading to a variety of inconsistent approaches. In this study, fixtures and methods were developed to perform push-out tests in accordance with the following design objectives: (i) the system rigidly fixes the explanted calvarial sample, (ii) it minimizes lateral bending, (iii) it positions the defect accurately, and (iv) it permits verification of the coaxial alignment of the defect with the push-out rod. The fixture and method was first validated by completing push-out experiments on 30 explanted murine cranial caps and two explanted leporine cranial caps, all induced with bilateral sub-critical defects (5.0 mm and 8.0 mm nominal diameter for the murine and leporine models, respectively). Defects were treated with an autograft (i.e., excised tissue flap), a shape memory polymer (SMP) scaffold, or a PEEK implant. Additional validation was performed on 24 murine cranial caps induced with a single, unilateral critically-sized defect (8.0 mm nominal diameter) and treated with an autograft or a SMP scaffold.A novel fixture was developed for performing push-out mechanical tests to characterize the strength of a bone-implant interface in calvarial defect repair. The fixture uses a 3D printed vertical clamp with mating alignment component to fix the sample in place without inducing lateral bending and verify coaxial alignment of push-out rod with the defect. The fixture can be scaled to different calvarial defect geometries as validated with 5.0 mm bilateral and 8.0 mm single diameter murine calvarial defect model and 8.0 mm bilateral leporine calvarial defect model.
Collapse
Affiliation(s)
- Zachary T Lawson
- Department of Biomedical Engineering, Texas A&M University, United States
| | - Jiwan Han
- Department of Mechanical Engineering, Texas A&M University, United States
| | - W Brian Saunders
- Department of Small Animal Clinical Sciences, Texas A&M University, United States
| | - Melissa A Grunlan
- Department of Biomedical Engineering, Texas A&M University, United States
| | - Michael R Moreno
- Department of Biomedical Engineering, Texas A&M University, United States.,Department of Mechanical Engineering, Texas A&M University, United States
| | - Andrew B Robbins
- Department of Multidisciplinary Engineering, Texas A&M University, United States
| |
Collapse
|
16
|
Arabiyat AS, Pfau MR, Grunlan MA, Hahn MS. Intrinsic osteoinductivity of PCL-DA/PLLA semi-IPN shape memory polymer scaffolds. J Biomed Mater Res A 2021; 109:2334-2345. [PMID: 33988292 PMCID: PMC8736335 DOI: 10.1002/jbm.a.37216] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/24/2021] [Revised: 04/22/2021] [Accepted: 05/01/2021] [Indexed: 02/06/2023]
Abstract
Engineering osteoinductive, self-fitting scaffolds offers a potential treatment modality to repair irregularly shaped craniomaxillofacial bone defects. Recently, we innovated on osteoinductive poly(ε-caprolactone)-diacrylate (PCL-DA) shape memory polymers (SMPs) to incorporate poly-L-lactic acid (PLLA) into the PCL-DA network, forming a semi-interpenetrating network (semi-IPN). Scaffolds formed from these PCL-DA/PLLA semi-IPNs display stiffnesses within the range of trabecular bone and accelerated degradation relative to scaffolds formed from slowly degrading PCL-DA SMPs. Herein, we demonstrate for the first time that PCL-DA/PLLA semi-IPN SMP scaffolds show increased intrinsic osteoinductivity relative to PCL-DA. We also confirm that application of a bioinspired polydopamine (PD) coating further improves the osteoinductive capacity of these PCL-DA/PLLA semi-IPN SMPs. In the absence of osteogenic supplements, protein level assessment of human mesenchymal stem cells (h-MSCs) cultured in PCL-DA/PLLA scaffolds revealed an increase in expression of osteogenic markers osterix, bone morphogenetic protein-4 (BMP-4), and collagen 1 alpha 1 (COL1A1), relative to PCL-DA scaffolds and osteogenic medium controls. Likewise, the expression of runt-related transcription factor 2 (RUNX2) and BMP-4 was elevated in the presence of PD-coating. In contrast, the chondrogenic and adipogenic responses associated with the scaffolds matched or were reduced relative to osteogenic medium controls, indicating that the scaffolds display intrinsic osteoinductivity.
Collapse
Affiliation(s)
- Ahmad S. Arabiyat
- Department of Biomedical Engineering, Rensselaer Polytechnic Institute (RPI), Troy, New York
- Center for Biotechnology and Interdisciplinary Studies, Rensselaer Polytechnic Institute (RPI), Troy, New York
| | - Michaela R. Pfau
- Department of Biomedical Engineering, Texas A&M University, College Station, Texas
| | - Melissa A. Grunlan
- Department of Biomedical Engineering, Texas A&M University, College Station, Texas
- Department of Materials Science and Engineering, Texas A&M University, College Station, Texas
- Department of Chemistry, Texas A&M University, College Station, Texas
| | - Mariah S. Hahn
- Department of Biomedical Engineering, Rensselaer Polytechnic Institute (RPI), Troy, New York
- Center for Biotechnology and Interdisciplinary Studies, Rensselaer Polytechnic Institute (RPI), Troy, New York
| |
Collapse
|
17
|
Abstract
Smart scaffolds based on shape memory polymer (SMPs) have been increasingly studied in tissue engineering. The unique shape actuating ability of SMP scaffolds has been utilized to improve delivery and/or tissue defect filling. In this regard, these scaffolds may be self-deploying, self-expanding, or self-fitting. Smart scaffolds are generally thermoresponsive or hydroresponsive wherein shape recovery is driven by an increase in temperature or by hydration, respectively. Most smart scaffolds have been directed towards regenerating bone, cartilage, and cardiovascular tissues. A vast variety of smart scaffolds can be prepared with properties targeted for a specific tissue application. This breadth of smart scaffolds stems from the variety of compositions employed as well as the numerous methods used to fabricated scaffolds with the desired morphology. Smart scaffold compositions span across several distinct classes of SMPs, affording further tunability of properties using numerous approaches. Specifically, these SMPs include those based on physically cross-linked and chemically cross-linked networks and include widely studied shape memory polyurethanes (SMPUs). Various additives, ranging from nanoparticles to biologicals, have also been included to impart unique functionality to smart scaffolds. Thus, given their unique functionality and breadth of tunable properties, smart scaffolds have tremendous potential in tissue engineering.
Collapse
Affiliation(s)
- Michaela R Pfau
- Department of Biomedical Engineering, Texas A&M University, College Station, TX 77843, USA.
| | - Melissa A Grunlan
- Department of Biomedical Engineering, Texas A&M University, College Station, TX 77843, USA. and Department of Materials Science and Engineering, Texas A&M University, College Station, TX 77843, USA and Department of Chemistry, Texas A&M University, College Station, TX 77843, USA
| |
Collapse
|
18
|
Dogbevi KS, Gordon P, Branan KL, Ngo BKD, Kiefer KB, Mertens-Talcott SU, Grunlan MA, Coté GL. Brightfield and fluorescence in-channel staining of thin blood smears generated in a pumpless microfluidic. Anal Methods 2021; 13:2238-2247. [PMID: 33929476 DOI: 10.1039/d1ay00195g] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/12/2023]
Abstract
Effective staining of peripheral blood smears by increasing contrast of intracellular components and biomarkers is essential for the accurate characterization, diagnosis, and monitoring of various diseases such as malaria. To assess the potential for automation of stained whole human blood smears at the point-of-care (POC), brightfield and fluorescence staining protocols were adapted for smears generated in channels of pumpless microchannels and compared to a standard glass smear. A 3× concentration Giemsa brightfield staining solutions (10, 33, and 50% dilution), and Acridine Orange fluorescence staining solutions (12 μg mL-1) were evaluated with human blood smears containing malaria parasites within a microfluidic channel. Giemsa staining at 33% dilution showed an optimal combination of contrast and preservation of cellular morphology, while 50% dilutions showed significant cellular crenation and 10% dilutions did not show desired contrast in brightfield imaging. Fluorescence staining at 12 μg mL-1 using Acridine Orange showed clear separability between the fluorescent intensities of the malaria parasites and that of the red blood cells (RBCs) and background. However, compared to glass smears, these exhibited reduced signal intensity as well as inverted contrast of RBCs and background. These results demonstrate that peripheral thin blood smears generated in pumpless microfluidic can be successfully stained in-channel with a simple, one-step procedure to permit brightfield and fluorescence imaging.
Collapse
Affiliation(s)
- Kokou S Dogbevi
- Department of Biomedical Engineering, Texas A&M University, College Station, TX 77843, USA.
| | - Paul Gordon
- Department of Biomedical Engineering, Texas A&M University, College Station, TX 77843, USA.
| | - Kimberly L Branan
- Department of Biomedical Engineering, Texas A&M University, College Station, TX 77843, USA.
| | - Bryan Khai D Ngo
- Department of Biomedical Engineering, Texas A&M University, College Station, TX 77843, USA.
| | - Kevin B Kiefer
- Department of Nutrition and Food Science, Texas A&M University, College Station, TX 77843, USA
| | | | - Melissa A Grunlan
- Department of Biomedical Engineering, Texas A&M University, College Station, TX 77843, USA. and Department of Materials Science & Engineering, Texas A&M University, College Station, TX 77843, USA and Department of Chemistry, Texas A&M University, College Station, TX 77843, USA and Center for Remote Health Technologies & Systems, Texas A&M University, College Station, TX 77843, USA
| | - Gerard L Coté
- Department of Biomedical Engineering, Texas A&M University, College Station, TX 77843, USA. and Center for Remote Health Technologies & Systems, Texas A&M University, College Station, TX 77843, USA
| |
Collapse
|
19
|
Pfau MR, McKinzey KG, Roth AA, Graul LM, Maitland DJ, Grunlan MA. Shape memory polymer (SMP) scaffolds with improved self-fitting properties. J Mater Chem B 2021; 9:3826-3837. [PMID: 33979417 DOI: 10.1039/d0tb02987d] [Citation(s) in RCA: 7] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/26/2022]
Abstract
"Self-fitting" shape memory polymer (SMP) scaffolds prepared as semi-interpenetrating networks (semi-IPNs) with crosslinked linear-poly(ε-caprolactone)-diacrylate (PCL-DA, Mn∼10 kg mol-1) and linear-poly(l-lactic acid) (PLLA, Mn∼15 kg mol-1) [75/25 wt%] exhibited robust mechanical properties and accelerated degradation rates versus a PCL-DA scaffold control. However, their potential to treat irregular craniomaxillofacial (CMF) bone defects is limited by their relatively high fitting temperature (Tfit∼55 °C; related to the Tm of PCL) required for shape recovery (i.e. expansion) and subsequent shape fixation during press fitting of the scaffold, which can be harmful to surrounding tissue. Additionally, the viscosity of the solvent-based precursor solutions, cast over a fused salt template during fabrication, can limit scaffold size. Thus, in this work, analogous semi-IPN SMP scaffolds were formed with a 4-arm star-PCL-tetracryalate (star-PCL-TA) (Mn∼10 kg mol-1) and star-PLLA (Mn∼15 kg mol-1). To assess the impact of a star-polymer architecture, four semi-IPN compositions were prepared: linear-PCL-DA/linear-PLLA (L/L), linear-PCL-DA/star-PLLA (L/S), star-PCL-TA/linear-PLLA (S/L) and star-PCL-TA/star-PLLA (S/S). Two PCL controls were also prepared: LPCL (i.e. 100% linear-PCL-DA) and SPCL (i.e. 100% star-PCL-TA). The S/S semi-IPN scaffold exhibited particularly desirable properties. In addition to achieving a lower, tissue-safe Tfit (∼45 °C), it exhibited the fastest rate of degradation which is anticipated to more favourably permit neotissue infiltration. The radial expansion pressure exerted by the S/S semi-IPN scaffold at Tfit was greater than that of LPCL, which is expected to enhance osseointegration and mechanical stability. The intrinsic viscosity of the S/S semi-IPN macromer solution was also reduced such that larger scaffold specimens could be prepared.
Collapse
Affiliation(s)
- Michaela R Pfau
- Department of Biomedical Engineering, Texas A&M University, College Station, TX 77843, USA.
| | | | | | | | | | | |
Collapse
|
20
|
Suriboot J, Marmo AC, Ngo BKD, Nigam A, Ortiz-Acosta D, Tai BL, Grunlan MA. Amphiphilic, thixotropic additives for extrusion-based 3D printing of silica-reinforced silicone. Soft Matter 2021; 17:4133-4142. [PMID: 33735370 DOI: 10.1039/d1sm00288k] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/12/2023]
Abstract
The ability to utilize extrusion-based, direct ink write (DIW) 3D printing to create silica-reinforced silicones with complex structures could expand their utility in industrial and biomedical applications. Sylgard 184, a common Pt-cure silicone, lacks the thixotropic behavior necessary for effective printing and its hydrophobicity renders cured structures susceptible to biofouling. Herein, we evaluated the efficacy of various PEO-silane amphiphiles (PEO-SAs) as thixotropic and surface modifying additives in Sylgard 184. Eight amphiphilic PEO-SAs of varying architecture (e.g. linear, star, and graft), crosslinkability, and PEO content were evaluated. Modified formulations were also prepared with additional amounts of silica filler, both hexamethyldisilazane (HMDS)-treated and dimethyldichlorosilane (DiMeDi)-treated types. Numerous PEO-SA modified silicone formulations demonstrated effective water-driven surface hydrophilicity that was generally diminished with the addition of HMDS-treated silica filler. While increased yield stress was observed for PEO-SA modified silicones with added HMDS-treated filler, none achieved the initial target for 3D printing (>1000 Pa). Only the formulations containing the DiMeDi-treated filler (17.3 wt%) were able to surpass this value. These formulations were then tested for their thixotropic properties and all surpassed the targets for recovered storage modulus (G') (>1000 Pa) and loss factor (<0.8). In particular, the triblock linear PEO-SA produced exceptionally high recovered G', low loss factor, and substantial water-driven restructuring to form a hydrophilic surface. Combined, these results demonstrate the potential of silicones modified with PEO-SA surface-modifying additives (SMAs) for extrusion-based, DIW 3D printing applications.
Collapse
Affiliation(s)
- Jakkrit Suriboot
- Department of Biomedical Engineering, Texas A&M University, College Station, TX 77843, USA.
| | - Alec C Marmo
- Department of Materials Science and Engineering, Texas A&M University, College Station, TX 77843, USA
| | - Bryan Khai D Ngo
- Department of Biomedical Engineering, Texas A&M University, College Station, TX 77843, USA.
| | - Aman Nigam
- Department of Mechanical Engineering, Texas A&M University, College Station, TX 77843, USA
| | | | - Bruce L Tai
- Department of Mechanical Engineering, Texas A&M University, College Station, TX 77843, USA
| | - Melissa A Grunlan
- Department of Biomedical Engineering, Texas A&M University, College Station, TX 77843, USA. and Department of Materials Science and Engineering, Texas A&M University, College Station, TX 77843, USA and Department of Chemistry, Texas A&M University, College Station, TX 77843, USA
| |
Collapse
|
21
|
Abstract
A material-guided, regenerative approach to heal cranial defects requires a scaffold that cannot only achieve conformal fit into irregular geometries but also has bioactivity and suitable resorption rates. We have previously reported "self-fitting" shape-memory polymer (SMP) scaffolds based on poly(ε-caprolactone) diacrylate (PCL-DA) that shape recover to fill irregular defect geometries. However, PCL-DA scaffolds lack innate bioactivity and degrade very slowly. Polydimethylsiloxane (PDMS) has been shown to impart innate bioactivity and modify degradation rates when combined with organic cross-linked networks. Thus, this work reports the introduction of PDMS segments to form PCL/PDMS SMP scaffolds. These were prepared as co-matrices with three types of macromers to systematically alter PDMS content and cross-link density. Specifically, PCL90-DA was combined with linear-PDMS66-dimethacrylate (DMA) or 4-armed star-PDMS66-tetramethacrylate (TMA) macromers at 90:10, 75:25, and 60:40 wt % ratios. Additionally, a triblock macromer (AcO-PCL45-b-PDMS66-b-PCL45-OAc), having a 65:35 wt % ratio PCL/PDMS, was used. Scaffolds exhibited pore interconnectivity and uniform pore sizes and further maintained excellent shape-memory behavior. Degradation rates increased with PDMS content and reduced cross-link density, with phase separation contributing to this effect. Irrespective of PDMS content, all PCL/PDMS scaffolds exhibited the formation of carbonated hydroxyapatite (HAp) following exposure to simulated body fluid (SBF). While inclusion of PDMS expectedly reduced scaffold modulus and strength, mineralization increased these properties and, in some cases, to values exceeding or similar to the PCL-DA, which did not mineralize.
Collapse
Affiliation(s)
- Felipe O Beltran
- Department of Materials Science and Engineering, Texas A&M University, College Station, Texas 77843, United States
| | - Christopher J Houk
- Department of Biomedical Engineering, Texas A&M University, College Station, Texas 77843, United States
| | - Melissa A Grunlan
- Department of Materials Science and Engineering, Texas A&M University, College Station, Texas 77843, United States.,Department of Biomedical Engineering, Texas A&M University, College Station, Texas 77843, United States.,Department of Chemistry, Texas A&M University, College Station, Texas 77843, United States
| |
Collapse
|
22
|
Quiñones-Pérez M, Cieza RJ, Ngo BKD, Grunlan MA, Domenech M. Amphiphilic silicones to reduce the absorption of small hydrophobic molecules. Acta Biomater 2021; 121:339-348. [PMID: 33271355 DOI: 10.1016/j.actbio.2020.11.041] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/20/2020] [Revised: 11/23/2020] [Accepted: 11/25/2020] [Indexed: 12/19/2022]
Abstract
Silicones (i.e. crosslinked poly(dimethylsiloxane), PDMS) are commonly used material for microfluidic device fabrication. Nonetheless, due to the uncontrollable absorption of small hydrophobic molecules (<1 kDa) into the bulk, its applicability to cell-based drug assays and sensing applications has been limited. Here, we demonstrate the use of substrates made of silicones bulk modified with a poly(ethylene oxide) silane amphiphile (PEO-SA) to reduce hydrophobic small molecule sequestration for cell-based assays. Modified silicone substrates were generated with concentrations of 2 wt.%, 9 wt.% and, 14 wt.% PEO-SA. Incorporation of PEO-SA into the silicone bulk was assessed by FTIR analysis in addition to water contact angle analysis to evaluate surface hydrophobicity. Cell toxicity, absorption of small hydrophobic drugs, and cell response to hydrophobic molecules were also evaluated. Results showed that the incorporation of the PEO-SA into the silicone led to a reduction in water contact angle from 114° to as low as 16° that was stable for at least three months. The modified silicones showed viability values above 85% for NIH-3T3, MCF7, MDA-MB-468, and MDA-MB-231 cell lines. A drug response assay using tamoxifen and the MCF7 cell line showed full recovery of cell toxicity response when exposed to PDMS modified with 9 wt.% or 14 wt.% PEO-SA compared to tissue culture plastic. Therefore, our study supports the use of PEO-SA at concentrations of 9 wt.% or higher for enhanced surface wettability and reduced absorption of small hydrophobic molecules in PDMS-based platforms.
Collapse
Affiliation(s)
- Manuel Quiñones-Pérez
- Industrial Biotechnology Program, University of Puerto Rico Mayagüez, PR-108, Mayagüez, PR 00682, Puerto Rico
| | - Ruben J Cieza
- Chemical Engineering Department, University of Puerto Rico Mayagüez, PR-108, Mayagüez, PR 00682, Puerto Rico
| | - Bryan Khai D Ngo
- Department of Biomedical Engineering, Department of Materials Science & Engineering, Department of Chemistry, Texas A&M University, College Station, TX 77843, USA
| | - Melissa A Grunlan
- Department of Biomedical Engineering, Department of Materials Science & Engineering, Department of Chemistry, Texas A&M University, College Station, TX 77843, USA
| | - Maribella Domenech
- Chemical Engineering Department, University of Puerto Rico Mayagüez, PR-108, Mayagüez, PR 00682, Puerto Rico.
| |
Collapse
|
23
|
Abstract
Scaffolds that recapitulate the spatial complexity of orthopedic interfacial tissues are essential to their regeneration. This requires a method to readily and flexibly produce scaffolds with spatial control over physical and chemical properties, without resulting in hard interfaces. Herein, we produced hydrogel scaffolds with spatially tunable arrangements and chemistries (SSTACs). Using solvent-induced phase separation/fused salt templating (SIPS/salt), scaffold elements are initially prepared with a tunable pore size and with one or more UV-reactive macromers. After trimming to the desired dimensions, these are physically configured and fused together to form the SSTACs. Using this method, three SSTAC designs were prepared, including one that mimicked the osteochondral interface. Bright-field/fluorescent microscopy revealed spatial control of pore size and chemical composition across a relatively smooth and integrated interface, regardless of layer composition. An interface formed by a SSTAC was determined to withstand a similar shear force to an analogous scaffold with no interface.
Collapse
Affiliation(s)
- Michael T. Frassica
- Department of Biomedical Engineering, Texas A&M University, College Station, Texas 77843-2120, United States
| | - Connor J. Demott
- Department of Biomedical Engineering, Texas A&M University, College Station, Texas 77843-2120, United States
| | - Esteban M. Ramirez
- Department of Biomedical Engineering, Texas A&M University, College Station, Texas 77843-2120, United States
| | - Melissa A. Grunlan
- Department of Biomedical Engineering, Texas A&M University, College Station, Texas 77843-2120, United States
- Department of Materials Science & Engineering, Texas A&M University, College Station, Texas 77843-3003, United States
- Department of Chemistry, Texas A&M University, College Station, Texas 77843-3255, United States
| |
Collapse
|
24
|
Bonyadi SZ, Demott CJ, Grunlan MA, Dunn AC. Cartilage-like tribological performance of charged double network hydrogels. J Mech Behav Biomed Mater 2020; 114:104202. [PMID: 33243694 DOI: 10.1016/j.jmbbm.2020.104202] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/30/2020] [Revised: 10/16/2020] [Accepted: 11/06/2020] [Indexed: 10/23/2022]
Abstract
A synthetic hydrogel material may offer utility as a cartilage replacement if it is able to maintain low friction in different sliding environments and achieve bulk mechanical properties to withstand the severe environment of the joint. In this work, we compared the tribological behavior of four double network (DN) hydrogels to that of fresh porcine cartilage in both water and fetal bovine serum (FBS). The DN hydrogels were comprised of a negatively charged 1st network and a 2nd network wherein comonomers of varying charge (i.e. neutral, positive, negative, and zwitterionic) were introduced at 10 wt% to an otherwise neutral network. A steel ball probe was used to perform microindentation tests to determine the surface elastic modulus of the samples and estimate their contact areas during sliding. Friction tests using a stationary probe with a stage that reciprocated at a range of speeds were performed to develop lubrication curves in both water and FBS. We found that the DN hydrogels with a neutral or zwitterionic 2nd network had the lowest friction and shear stresses, notably below that of cartilage. The differences in charge and structure of the samples were more evident in water than in FBS, as the lubrication responses for all the hydrogels spanned a wider range of values. In FBS, the lubrication responses were pushed towards elasto-hydrodynamics with nearly all friction coefficient values falling below 0.3. This indicates that the FBS interacts with the hydrogels and cartilage samples in a similar manner as that of cartilage by maintaining a robust layer of solution at the interface during sliding. These DN hydrogels prove to fulfill, and in some cases surpass, the lubrication demands for cartilage replacement in load bearing joints.
Collapse
Affiliation(s)
- Shabnam Z Bonyadi
- Department of Mechanical Science & Engineering, University of Illinois at Urbana-Champaign, Urbana, IL, USA
| | - Connor J Demott
- Department of Biomedical Engineering, Texas A&M University, College Station, TX, USA
| | - Melissa A Grunlan
- Department of Biomedical Engineering, Texas A&M University, College Station, TX, USA; Department of Materials Science & Engineering, Texas A&M University, College Station, TX, USA; Department of Chemistry, Texas A&M University, College Station, TX, USA
| | - Alison C Dunn
- Department of Mechanical Science & Engineering, University of Illinois at Urbana-Champaign, Urbana, IL, USA.
| |
Collapse
|
25
|
Frassica MT, Jones SK, Suriboot J, Arabiyat AS, Ramirez EM, Culibrk RA, Hahn MS, Grunlan MA. Enhanced Osteogenic Potential of Phosphonated-Siloxane Hydrogel Scaffolds. Biomacromolecules 2020; 21:5189-5199. [DOI: 10.1021/acs.biomac.0c01293] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/21/2022]
Affiliation(s)
- Michael T. Frassica
- Department of Biomedical Engineering, Texas A&M University, College Station, Texas 77843-3120, United States
| | - Sarah K. Jones
- Department of Biomedical Engineering, Texas A&M University, College Station, Texas 77843-3120, United States
| | - Jakkrit Suriboot
- Department of Biomedical Engineering, Texas A&M University, College Station, Texas 77843-3120, United States
| | - Ahmad S. Arabiyat
- Department of Biomedical Engineering, Rensselaer Polytechnic Institute, Troy, New York 12180-31590, United States
| | - Esteban M. Ramirez
- Department of Biomedical Engineering, Texas A&M University, College Station, Texas 77843-3120, United States
| | - Robert A. Culibrk
- Department of Biomedical Engineering, Rensselaer Polytechnic Institute, Troy, New York 12180-31590, United States
| | - Mariah S. Hahn
- Department of Biomedical Engineering, Rensselaer Polytechnic Institute, Troy, New York 12180-31590, United States
| | - Melissa A. Grunlan
- Department of Biomedical Engineering, Texas A&M University, College Station, Texas 77843-3120, United States
- Department of Materials Science & Engineering, Texas A&M University, College Station, Texas 77843-3003, United States
- Department of Chemistry, Texas A&M University, College Station, Texas 77843-3255, United States
| |
Collapse
|
26
|
Ngo BKD, Lim KK, Johnson JC, Jain A, Grunlan MA. Thromboresistance of Polyurethanes Modified with PEO-Silane Amphiphiles. Macromol Biosci 2020; 20:e2000193. [PMID: 32812374 DOI: 10.1002/mabi.202000193] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/02/2020] [Revised: 08/02/2020] [Indexed: 11/07/2022]
Abstract
Surface-induced thrombosis is problematic in blood-contacting devices composed of silicones or polyurethanes (PUs). Poly(ethylene oxide)-silane amphiphiles (PEO-SA) are previously shown effective as surface modifying additives (SMAs) in silicones for enhanced thromboresistance. This study investigates PEO-SAs as SMAs in a PU at various concentrations: 5, 10, 25, 50, and 100 µmol g-1 PU. PEO-SA modified PUs are evaluated for their mechanical properties, water-driven surface restructuring, and adhesion resistance against a human fibrinogen (HF) solution as well as whole human blood. Stability is assessed by monitoring hydrophilicity, water uptake, and mass loss following air- or aqueous-conditioning. PEO-SA modified PUs do not demonstrate plasticization, as evidenced by minimal changes in glass transition temperature, modulus, tensile strength, and percent strain at break. These also show a concentration-dependent increase in hydrophilicity that is sustained following air- and aqueous-conditioning for concentrations ≥25 µmol g-1 . Additionally, water uptake and mass loss are minimal at all concentrations. Although protein resistance is not enhanced versus an HF solution, PEO-SA modified PUs have significantly reduced protein adsorption and platelet adhesion from human blood at concentrations ≥10 µmol g-1 . Overall, this study demonstrates the versatility of PEO-SAs as SMAs in PU, which leads to enhanced and sustained hydrophilicity as well as thromboresistance.
Collapse
Affiliation(s)
- Bryan Khai D Ngo
- Department of Biomedical Engineering, Texas A&M University, College Station, TX, 77843, USA
| | - Kendrick K Lim
- Department of Biomedical Engineering, Texas A&M University, College Station, TX, 77843, USA
| | - Jessica C Johnson
- Department of Biomedical Engineering, Texas A&M University, College Station, TX, 77843, USA
| | - Abhishek Jain
- Department of Biomedical Engineering, Texas A&M University, College Station, TX, 77843, USA.,Department of Medical Physiology, Texas A&M University Health Science Center, Bryan, TX, 77807, USA
| | - Melissa A Grunlan
- Department of Biomedical Engineering, Texas A&M University, College Station, TX, 77843, USA.,Department of Materials Science and Engineering, Texas A&M University, College Station, TX, 77843, USA.,Department of Chemistry, Texas A&M University, College Station, TX, 77843, USA
| |
Collapse
|
27
|
Abstract
Regenerative engineering holds the potential to treat clinically pervasive osteochondral defects (OCDs). In a synthetic materials-guided approach, the scaffold's chemical and physical properties alone instruct cellular behavior in order to effect regeneration, referred to herein as "instructive" properties. While this alleviates the costs and off-target risks associated with exogenous growth factors, the scaffold must be potently instructive to achieve tissue growth. Moreover, toward achieving functionality, such a scaffold should also recapitulate the spatial complexity of the osteochondral tissues. Thus, in addition to the regeneration of the articular cartilage and underlying cancellous bone, the complex osteochondral interface, composed of calcified cartilage and subchondral bone, should also be restored. In this Perspective, we highlight recent synthetic-based, instructive osteochondral scaffolds that have leveraged new material chemistries as well as innovative fabrication strategies. In particular, scaffolds with spatially complex chemical and morphological features have been prepared with electrospinning, solvent-casting-particulate-leaching, freeze-drying, and additive manufacturing. While few synthetic scaffolds have advanced to clinical studies to treat OCDs, these recent efforts point to the promising use of the chemical and physical properties of synthetic materials for regeneration of osteochondral tissues.
Collapse
Affiliation(s)
- Michael T Frassica
- Department of Biomedical Engineering, Texas A&M University, College Station, Texas 77843-2120, United States
| | - Melissa A Grunlan
- Department of Biomedical Engineering, Texas A&M University, College Station, Texas 77843-2120, United States.,Department of Materials Science & Engineering, Texas A&M University, College Station, Texas 77843-3003, United States.,Department of Chemistry, Texas A&M University, College Station, Texas 77843-3255, United States
| |
Collapse
|
28
|
Pfau MR, McKinzey KG, Roth AA, Grunlan MA. PCL-Based Shape Memory Polymer Semi-IPNs: The Role of Miscibility in Tuning the Degradation Rate. Biomacromolecules 2020; 21:2493-2501. [DOI: 10.1021/acs.biomac.0c00454] [Citation(s) in RCA: 15] [Impact Index Per Article: 3.8] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/11/2022]
Affiliation(s)
- Michaela R. Pfau
- Department of Biomedical Engineering, Texas A&M University, College Station Texas 77843, United States
| | - Kelly G. McKinzey
- Department of Biomedical Engineering, Texas A&M University, College Station Texas 77843, United States
| | - Abigail A. Roth
- Department of Biomedical Engineering, Texas A&M University, College Station Texas 77843, United States
| | - Melissa A. Grunlan
- Department of Biomedical Engineering, Texas A&M University, College Station Texas 77843, United States
- Department of Materials Science and Engineering, Texas A&M University, College Station Texas 77843, United States
- Department of Chemistry, Texas A&M University, College Station Texas 77843, United States
| |
Collapse
|
29
|
Ngo BKD, Barry ME, Lim KK, Johnson JC, Luna DJ, Pandian NK, Jain A, Grunlan MA. Thromboresistance of Silicones Modified with PEO-Silane Amphiphiles. ACS Biomater Sci Eng 2020; 6:2029-2037. [DOI: 10.1021/acsbiomaterials.0c00011] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/28/2023]
Affiliation(s)
- Bryan Khai D. Ngo
- Department of Biomedical Engineering, Texas A&M University, College Station, Texas 77843, United States
| | - Mikayla E. Barry
- Department of Biomedical Engineering, Texas A&M University, College Station, Texas 77843, United States
| | - Kendrick K. Lim
- Department of Biomedical Engineering, Texas A&M University, College Station, Texas 77843, United States
| | - Jessica C. Johnson
- Department of Biomedical Engineering, Texas A&M University, College Station, Texas 77843, United States
| | - David J. Luna
- Department of Biomedical Engineering, Texas A&M University, College Station, Texas 77843, United States
| | - Navaneeth K.R. Pandian
- Department of Biomedical Engineering, Texas A&M University, College Station, Texas 77843, United States
| | - Abhishek Jain
- Department of Biomedical Engineering, Texas A&M University, College Station, Texas 77843, United States
| | - Melissa A. Grunlan
- Department of Biomedical Engineering, Texas A&M University, College Station, Texas 77843, United States
- Department of Materials Science & Engineering, Texas A&M University, College Station, Texas 77843, United States
- Department of Chemistry, Texas A&M University, College Station, Texas 77843, United States
| |
Collapse
|
30
|
Abstract
Accelerating the rate of polyester hydrolytic degradation is of interest for numerous biomedical applications. Poly(ε-caprolactone) (PCL) and poly(L-lactic acid) (PLLA) have been extensively studied as thermoplastic homo- and copolymers as well as PCL-PLLA blends. PCL-PLLA semi-interpenetrating networks (semi-IPN) prepared with thermoplastic PLLA embedded in a cross-linked PCL diacrylate (PCL-DA) network were previously shown to exhibit uniquely accelerated degradation behavior that increased with PLLA content. Herein, their properties before and during degradation were further investigated to reveal the origin of this behavior and to better understand the semi-IPNs' degradation mechanism. Initially, semi-IPNs exhibited restricted spherulite size and irregularity, as well as a phase-separated morphology and PLLA-rich surface. Under accelerated conditions (1 M NaOH, 37 °C), degradation was revealed to be initiated in PLLA regions. It was also found that the PCL-DA crosslinking and PCL-PLLA phase separation played the largest roles in degradation rates and that semi-IPNs underwent faster rates of degradation than an analogous blend largely due to the reduced crystallinity of PCL-DA. Non-accelerated conditions (PBS [pH = 7.4], 37 °C) up to 56 weeks, which had never before been studied for polyester semi-IPNs, revealed similar trends in degradation rates.
Collapse
Affiliation(s)
- Lindsay N Woodard
- Department of Biomedical Engineering, Texas A&M University, College Station, Texas 77843, United States
| | - Melissa A Grunlan
- Department of Biomedical Engineering, Texas A&M University, College Station, Texas 77843, United States.,Department of Materials Science and Engineering, Texas A&M University, College Station, Texas 77843, United States.,Department of Chemistry, Texas A&M University, College Station, Texas 77843, United States
| |
Collapse
|
31
|
Frassica MT, Jones SK, Diaz-Rodriguez P, Hahn MS, Grunlan MA. Incorporation of a silicon-based polymer to PEG-DA templated hydrogel scaffolds for bioactivity and osteoinductivity. Acta Biomater 2019. [PMID: 31536841 DOI: 10.1016/j.actbio.2019.09.018.] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/01/2022]
Abstract
A scaffold that is inherently bioactive, osteoinductive and osteoconductive may guide mesenchymal stem cells (MSCs) to regenerate bone tissue in the absence of exogenous growth factors. Previously, we established that hydrogel scaffolds formed by crosslinking methacrylated star poly(dimethylsiloxane) (PDMSstar-MA) with diacrylated poly(ethylene glycol) (PEG-DA) promote bone bonding by induction of hydroxyapatite formation ("bioactive") and promote MSC lineage progression toward osteoblast-like fate ("osteoinductive"). Herein, we have combined solvent induced phase separation (SIPS) with a fused salt template to create PDMSstar-PEG hydrogel scaffolds with controlled PDMSstar-MA distribution as well as interconnected macropores of a tunable size to allow for subsequent cell seeding and neotissue infiltration ("osteoconductive"). Scaffolds were prepared with PDMSstar-MA of two number average molecular weights (Mns) (2k and 7k) with varying PDMSstar-MA:PEG-DA ratios and template salt sizes. The distribution of PDMSstar-MA within the hydrogels was examined as well as pore size, percent interconnectivity, dynamic and static moduli, hydration, degradation and in vitro bioactivity (i.e. mineralization when exposed to simulated body fluid, SBF). Finally, cell culture with seeded human bone marrow-derived MSCs (hBMSCs) was used to confirm non-cytotoxicity and characterize osteoinductivity. Tunable, interconnected macropores were achieved by utilization of a fused salt template of a specified salt size during fabrication. Distribution of PDMSstar-MA within the PEG-DA matrix improved for the lower Mn and contributed to differences in specific material properties (e.g. local modulus) and cellular response. However, all templated SIPS PDMSstar-PEG hydrogels were confirmed to be bioactive, non-cytotoxic and displayed PDMSstar-MA dose-dependent osteogenesis. STATEMENT OF SIGNIFICANCE: A tissue engineering scaffold that can inherently guide mesenchymal stem cells (MSCs) to regenerate bone tissue without growth factors would be a more cost-effective and safe strategy for bone repair. Typically, glass/ceramic fillers are utilized to achieve this through their ability to induce hydroxyapatite formation ("bioactive") and promote MSC differentiation to an osteoblast-like fate ("osteoinductive"). Herein, we have fabricated an interconnected, macroporous PEG-DA hydrogel scaffold that utilizes PDMSstar-MA as a bioactive and osteoinductive scaffold component. We were able to show that these PDMSstar-PEG hydrogels maintain several key material characteristics for bone repair. Further, bioactivity and osteoinductivity were simultaneously achieved in human bone marrow-derived MSC culture, representing a notable achievement for an exclusively material-based strategy.
Collapse
Affiliation(s)
- Michael T Frassica
- Department of Biomedical Engineering, Texas A&M University, College Station, TX 77843-3120, USA
| | - Sarah K Jones
- Department of Biomedical Engineering, Texas A&M University, College Station, TX 77843-3120, USA
| | - Patricia Diaz-Rodriguez
- Department of Biomedical Engineering, Rensselaer Polytechnic Institute, Troy, NY 12180-31590, USA
| | - Mariah S Hahn
- Department of Biomedical Engineering, Rensselaer Polytechnic Institute, Troy, NY 12180-31590, USA
| | - Melissa A Grunlan
- Department of Biomedical Engineering, Texas A&M University, College Station, TX 77843-3120, USA; Department of Materials Science & Engineering, Texas A&M University, College Station, TX 77843-3003, USA; Department of Chemistry, Texas A&M University, College Station, TX 77843-3255, USA.
| |
Collapse
|
32
|
Diaz-Rodriguez P, Erndt-Marino JD, Gharat T, Munoz Pinto DJ, Samavedi S, Bearden R, Grunlan MA, Saunders WB, Hahn MS. Toward zonally tailored scaffolds for osteochondral differentiation of synovial mesenchymal stem cells. J Biomed Mater Res B Appl Biomater 2019; 107:2019-2029. [PMID: 30549205 PMCID: PMC6934364 DOI: 10.1002/jbm.b.34293] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/23/2018] [Revised: 10/22/2018] [Accepted: 11/10/2018] [Indexed: 12/15/2022]
Abstract
Synovium-derived mesenchymal stem cells (SMSCs) are an emerging cell source for regenerative medicine applications, including osteochondral defect (OCD) repair. However, in contrast to bone marrow MSCs, scaffold compositions which promote SMSC chondrogenesis/osteogenesis are still being identified. In the present manuscript, we examine poly(ethylene) glycol (PEG)-based scaffolds containing zonally-specific biochemical cues to guide SMSC osteochondral differentiation. Specifically, SMSCs were encapsulated in PEG-based scaffolds incorporating glycosaminoglycans (hyaluronan or chondroitin-6-sulfate [CSC]), low-dose of chondrogenic and osteogenic growth factors (TGFβ1 and BMP2, respectively), or osteoinductive poly(dimethylsiloxane) (PDMS). Initial studies suggested that PEG-CSC-TGFβ1 scaffolds promoted enhanced SMSC chondrogenic differentiation, as assessed by significant increases in Sox9 and aggrecan. Conversely, PEG-PDMS-BMP2 scaffolds stimulated increased levels of osteoblastic markers with significant mineral deposition. A "Transition" zone formulation was then developed containing a graded mixture of the chondrogenic and osteogenic signals present in the PEG-CSC-TGFβ1 and PEG-PDMS-BMP2 constructs. SMSCs within the "Transition" formulation displayed a phenotypic profile similar to hypertrophic chondrocytes, with the highest expression of collagen X, intermediate levels of osteopontin, and mineralization levels equivalent to "bone" formulations. Overall, these results suggest that a graded transition from PEG-CSC-TGFβ1 to PEG-PDMS-BMP2 scaffolds elicits a gradual SMSC phenotypic shift from chondrocyte to hypertrophic chondrocyte to osteoblast-like. As such, further development of these scaffold formulations for use in SMSC-based OCD repair is warranted. © 2018 Wiley Periodicals, Inc. J Biomed Mater Res Part B: Appl Biomater 107B: 2019-2029, 2019.
Collapse
Affiliation(s)
| | - Josh D Erndt-Marino
- Department of Biomedical Engineering, Rensselaer Polytechnic Institute, Troy, New York
| | - Tanmay Gharat
- Department of Chemical and Biological Engineering, Rensselaer Polytechnic Institute, Troy, New York
| | - Dany J Munoz Pinto
- Department of Biomedical Engineering, Rensselaer Polytechnic Institute, Troy, New York
| | - Satyavrata Samavedi
- Department of Biomedical Engineering, Rensselaer Polytechnic Institute, Troy, New York
| | - Robert Bearden
- Veterinary Medicine and Biomedical Sciences, Texas A&M University, College Station, Texas
| | - Melissa A Grunlan
- Department of Biomedical Engineering, Texas A&M University, College Station, Texas
| | - W Brian Saunders
- Veterinary Medicine and Biomedical Sciences, Texas A&M University, College Station, Texas
| | - Mariah S Hahn
- Department of Chemical and Biological Engineering, Rensselaer Polytechnic Institute, Troy, New York
| |
Collapse
|
33
|
Means AK, Dong P, Clubb FJ, Friedemann MC, Colvin LE, Shrode CA, Coté GL, Grunlan MA. A self-cleaning, mechanically robust membrane for minimizing the foreign body reaction: towards extending the lifetime of sub-Q glucose biosensors. J Mater Sci Mater Med 2019; 30:79. [PMID: 31240399 PMCID: PMC6988489 DOI: 10.1007/s10856-019-6282-2] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 01/14/2019] [Accepted: 06/17/2019] [Indexed: 06/09/2023]
Abstract
Long-term, subcutaneously implanted continuous glucose biosensors have the potential to improve diabetes management and reduce associated complications. However, the innate foreign body reaction (FBR) both alters the local glucose concentrations in the surrounding tissues and compromises glucose diffusion to the biosensor due to the recruitment of high-metabolizing inflammatory cells and the formation of a dense, collagenous fibrous capsule. Minimizing the FBR has mainly focused on "passively antifouling" materials that reduce initial cellular attachment, including poly(ethylene glycol) (PEG). Instead, the membrane reported herein utilizes an "actively antifouling" or "self-cleaning" mechanism to inhibit cellular attachment through continuous, cyclic deswelling/reswelling in response to normal temperature fluctuations of the subcutaneous tissue. This thermoresponsive double network (DN) membrane is based on N-isopropylacrylamide (NIPAAm) and 2-acrylamido-2-methylpropane sulfonic acid (AMPS) (75:25 and 100:0 NIPAAm:AMPS in the 1st and 2nd networks, respectively; "DN-25%"). The extent of the FBR reaction of a subcutaneously implanted DN-25% cylindrical membrane was evaluated in rodents in parallel with a PEG-diacrylate (PEG-DA) hydrogel as an established benchmark biocompatible control. Notably, the DN-25% implants were more than 25× stronger and tougher than the PEG-DA implants while maintaining a modulus near that of subcutaneous tissue. From examining the FBR at 7, 30 and 90 days after implantation, the thermoresponsive DN-25% implants demonstrated a rapid healing response and a minimal fibrous capsule (~20-25 µm), similar to the PEG-DA implants. Thus, the dynamic self-cleaning mechanism of the DN-25% membranes represents a new approach to limit the FBR while achieving the durability necessary for long-term implantable glucose biosensors.
Collapse
Affiliation(s)
- A Kristen Means
- Department of Materials Science & Engineering, Texas A&M University, College Station, TX, 77843-3003, USA
| | - Ping Dong
- Department of Biomedical Engineering, Texas A&M University, College Station, TX, 77843-3120, USA
| | - Fred J Clubb
- Department of Biomedical Engineering, Texas A&M University, College Station, TX, 77843-3120, USA
- Department of Veterinary Pathobiology, Texas A&M University, College Station, TX, 77843-4467, USA
| | - Molly C Friedemann
- Department of Veterinary Pathobiology, Texas A&M University, College Station, TX, 77843-4467, USA
| | - Lydia E Colvin
- Department of Biomedical Engineering, Texas A&M University, College Station, TX, 77843-3120, USA
| | - Courtney A Shrode
- Department of Biomedical Engineering, Texas A&M University, College Station, TX, 77843-3120, USA
| | - Gerard L Coté
- Department of Biomedical Engineering, Texas A&M University, College Station, TX, 77843-3120, USA
- Center for Remote Health Technologies Systems, Texas A&M University, College Station, TX, 77843-3120, USA
| | - Melissa A Grunlan
- Department of Materials Science & Engineering, Texas A&M University, College Station, TX, 77843-3003, USA.
- Department of Biomedical Engineering, Texas A&M University, College Station, TX, 77843-3120, USA.
- Center for Remote Health Technologies Systems, Texas A&M University, College Station, TX, 77843-3120, USA.
- Department of Chemistry, Texas A&M University, College Station, TX, 77843-3255, USA.
| |
Collapse
|
34
|
Abstract
Hydrogels are frequently used biomaterials due to their similarity in hydration and structure to biological tissues. However, their utility is limited by poor mechanical properties, namely, a lack of strength and stiffness that mimic that of tissues, particularly load-bearing tissues. Thus, numerous recent strategies have sought to enhance and tune these properties in hydrogels, including interpenetrating networks (IPNs), macromolecular cross-linking, composites, thermal conditioning, polyampholytes, and dual cross-linking. Individually, these approaches have achieved hydrogels with either high strength (σ f > 10 MPa), high stiffness (E > 1 MPa), or, less commonly, both high strength and stiffness (σ f > 10 MPa and E > 1 MPa). However, only certain unique combinations of these approaches have been able to synergistically achieve retention of a high, tissuelike water content as well as high strength and stiffness. Applying such methods to stimuli-responsive hydrogels has also produced robust, smart biomaterials. Overall, methods to achieve hydrogels that simultaneously mimic the hydration, strength, and stiffness of soft and load-bearing tissues have the potential to be used in a much broader range of biomedical applications.
Collapse
Affiliation(s)
- A. Kristen Means
- Department of Materials Science & Engineering, Texas A&M University, College Station, Texas 77843-3003, United States
| | - Melissa A. Grunlan
- Department of Materials Science & Engineering, Texas A&M University, College Station, Texas 77843-3003, United States
- Department of Biomedical Engineering, Texas A&M University, College Station, Texas 77843-3120, United States
- Department of Chemistry, Texas A&M University, College Station, Texas 77843-3120, United States
- Center for Remote Health Technologies Systems, Texas A&M University, College Station, Texas 77843-3120, United States
| |
Collapse
|
35
|
Ngo BKD, Lim KK, Stafslien SJ, Grunlan MA. Stability of silicones modified with PEO-silane amphiphiles: Impact of structure and concentration. Polym Degrad Stab 2019. [DOI: 10.1016/j.polymdegradstab.2019.03.010] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [What about the content of this article? (0)] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/27/2022]
|
36
|
Means AK, Shrode CS, Whitney LV, Ehrhardt DA, Grunlan MA. Double Network Hydrogels that Mimic the Modulus, Strength, and Lubricity of Cartilage. Biomacromolecules 2019; 20:2034-2042. [DOI: 10.1021/acs.biomac.9b00237] [Citation(s) in RCA: 45] [Impact Index Per Article: 9.0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/15/2022]
Affiliation(s)
- A. Kristen Means
- Department of Materials Science & Engineering, Texas A&M University, College Station, Texas 77843-3003 United States
| | - Courtney S. Shrode
- Department of Biomedical Engineering, Texas A&M University, College Station, Texas 77843-3120 United States
| | - Lauren V. Whitney
- Department of Biomedical Engineering, Texas A&M University, College Station, Texas 77843-3120 United States
| | - Daniel A. Ehrhardt
- Department of Biomedical Engineering, Texas A&M University, College Station, Texas 77843-3120 United States
| | - Melissa A. Grunlan
- Department of Materials Science & Engineering, Texas A&M University, College Station, Texas 77843-3003 United States
- Department of Biomedical Engineering, Texas A&M University, College Station, Texas 77843-3120 United States
- Department of Chemistry, Texas A&M University, College Station, Texas 77843-3120 United States
- Center for Remote Health Technologies Systems, Texas A&M University, College Station, Texas 77843-3120 United States
| |
Collapse
|
37
|
Abstract
Accelerating the rate of polyester hydrolytic degradation is of interest for numerous biomedical applications. Poly(ε-caprolactone) (PCL) and poly(L-lactic acid) (PLLA) have been extensively studied as thermoplastic homo- and copolymers as well as PCL-PLLA blends. PCL-PLLA semi-interpenetrating networks (semi-IPN) prepared with thermoplastic PLLA embedded in a cross-linked PCL diacrylate (PCL-DA) network were previously shown to exhibit uniquely accelerated degradation behavior that increased with PLLA content. Herein, their properties before and during degradation were further investigated to reveal the origin of this behavior and to better understand the semi-IPNs' degradation mechanism. Initially, semi-IPNs exhibited restricted spherulite size and irregularity, as well as a phase-separated morphology and PLLA-rich surface. Under accelerated conditions (1 M NaOH, 37 °C), degradation was revealed to be initiated in PLLA regions. It was also found that the PCL-DA crosslinking and PCL-PLLA phase separation played the largest roles in degradation rates and that semi-IPNs underwent faster rates of degradation than an analogous blend largely due to the reduced crystallinity of PCL-DA. Non-accelerated conditions (PBS [pH = 7.4], 37 °C) up to 56 weeks, which had never before been studied for polyester semi-IPNs, revealed similar trends in degradation rates.
Collapse
Affiliation(s)
- Lindsay N Woodard
- Department of Biomedical Engineering, Texas A&M University, College Station, Texas 77843, United States
| | - Melissa A Grunlan
- Department of Biomedical Engineering, Texas A&M University, College Station, Texas 77843, United States.,Department of Materials Science and Engineering, Texas A&M University, College Station, Texas 77843, United States.,Department of Chemistry, Texas A&M University, College Station, Texas 77843, United States
| |
Collapse
|
38
|
Locke A, Means AK, Dong P, Nichols TJ, Coté GL, Grunlan MA. A Layer-by-Layer Approach To Retain a Fluorescent Glucose Sensing Assay within the Cavity of a Hydrogel Membrane. ACS Appl Bio Mater 2018; 1:1319-1327. [PMID: 30474080 PMCID: PMC6247246 DOI: 10.1021/acsabm.8b00267] [Citation(s) in RCA: 15] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/25/2018] [Accepted: 10/10/2018] [Indexed: 02/03/2023]
Abstract
A continuous glucose monitoring device that resides fully in the subcutaneous tissue has the potential to greatly improve the management of diabetes. Toward this goal, we have developed a competitive binding glucose sensing assay based on fluorescently labeled PEGylated concanavalin-A (PEGylated-TRITC-ConA) and mannotetraose (APTS-MT). In the present work, we sought to contain this assay within the hollow central cavity of a cylindrical hydrogel membrane, permitting eventual subcutaneous implantation and optical probing through the skin. A "self-cleaning" hydrogel was utilized because of its ability to cyclically deswell/reswell in vivo, which is expected to reduce biofouling and therefore extend the sensor lifetime. Thus, we prepared a hollow, cylindrical hydrogel based on a thermoresponsive electrostatic double network design composed of N-isopropylacrylamide and 2-acrylamido-2-methylpropanesulfonic acid. Next, a layer-by-layer (LbL) coating was applied to the inner wall of the central cavity of the cylindrical membrane. It consisted of 5, 10, 15, 30, or 40 alternating bilayers of positively charged poly(diallyldimethylammonium chloride) and negatively charged poly(sodium 4-styrenesulfonate). With 30 bilayers, the leaching of the smaller-sized component of the assay (APTS-MT) from the membrane cavity was substantially reduced. Moreover, this LbL coating maintained glucose diffusion across the hydrogel membrane. In terms of sensor functionality, the assay housed in the hydrogel membrane cavity tracked changes in glucose concentration (0 to 600 mg/dL) with a mean absolute relative difference of ∼11%.
Collapse
Affiliation(s)
- Andrea
K. Locke
- Department
of Biomedical Engineering, Department of Materials Science
and Engineering, Department of Chemistry, and Center for Remote Healthcare Technologies, Texas A&M University, College Station, Texas 77843-3120, United States
| | - Anna Kristen Means
- Department
of Biomedical Engineering, Department of Materials Science
and Engineering, Department of Chemistry, and Center for Remote Healthcare Technologies, Texas A&M University, College Station, Texas 77843-3120, United States
| | - Ping Dong
- Department
of Biomedical Engineering, Department of Materials Science
and Engineering, Department of Chemistry, and Center for Remote Healthcare Technologies, Texas A&M University, College Station, Texas 77843-3120, United States
| | - Tyler J. Nichols
- Department
of Biomedical Engineering, Department of Materials Science
and Engineering, Department of Chemistry, and Center for Remote Healthcare Technologies, Texas A&M University, College Station, Texas 77843-3120, United States
| | - Gerard L. Coté
- Department
of Biomedical Engineering, Department of Materials Science
and Engineering, Department of Chemistry, and Center for Remote Healthcare Technologies, Texas A&M University, College Station, Texas 77843-3120, United States
| | - Melissa A. Grunlan
- Department
of Biomedical Engineering, Department of Materials Science
and Engineering, Department of Chemistry, and Center for Remote Healthcare Technologies, Texas A&M University, College Station, Texas 77843-3120, United States
| |
Collapse
|
39
|
Abraham AA, Means AK, Clubb FJ, Fei R, Locke AK, Gacasan EG, Coté GL, Grunlan MA. Foreign Body Reaction to a Subcutaneously Implanted Self-Cleaning, Thermoresponsive Hydrogel Membrane for Glucose Biosensors. ACS Biomater Sci Eng 2018; 4:4104-4111. [PMID: 31633011 DOI: 10.1021/acsbiomaterials.8b01061] [Citation(s) in RCA: 17] [Impact Index Per Article: 2.8] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/29/2022]
Abstract
Towards achieveing a subcutaneously implanted glucose biosensor with long-term functionality, a thermoresponsive membrane previously shown to have potential to house a glucose sensing assay was evaluated herein for its ability to minimize the foriegn body reaction (FBR) and the resulting fibrous capsule. The severity of the FBR proportionally reduces diffusion of glucose to the sensor and hence sensor lifetime. However, efforts to reduce the FBR have largedly focused on anti-fouling materials that passively inhibit cellular attachment, particularly poly(ethylene glycol) (PEG). Herein, the extent of the FBR of a subcutaneously implanted "self-cleaning" cylindrical membrane was analyzed in rodents. This membrane represents an "actively anti-fouling" approach to reduce cellular adhesion. It is a thermoresponsive double network nanocomposite hydrogel (DNNC) comprised of poly(N-isopropylacrylamide) (PNIPAAm) and embedded polysiloxane nanoparticles. The membrane's cyclical deswelling/reswelling response to local body temperature fluctuations was anticipated to limit cellular accumulation. Indeed, after 30 days, the self-cleaning membrane exhibited a notably thin fibrous capsule (~30 µm) and increased microvascular density within 1 mm of the implant surface in comparison to a non-thermoresponsive, benchmark biocompatible control (PEG diacrylate, PEG-DA).
Collapse
Affiliation(s)
- Alexander A Abraham
- Department of Biomedical Engineering, Texas A&M University, College Station, TX 77843-2120 (USA)
| | - A Kristen Means
- Department of Materials Science & Engineering, Texas A&M University, College Station, TX 77843 (USA)
| | - Fred J Clubb
- Department of Biomedical Engineering, Texas A&M University, College Station, TX 77843-2120 (USA).,Department of Veterinary Pathobiology, Texas A&M University, College Station, Texas 77843-4467 (USA)
| | - Ruochong Fei
- Department of Biomedical Engineering, Texas A&M University, College Station, TX 77843-2120 (USA)
| | - Andrea K Locke
- Department of Biomedical Engineering, Texas A&M University, College Station, TX 77843-2120 (USA)
| | - Erica G Gacasan
- Department of Biomedical Engineering, Texas A&M University, College Station, TX 77843-2120 (USA)
| | - Gerard L Coté
- Department of Biomedical Engineering, Texas A&M University, College Station, TX 77843-2120 (USA).,Center for Remote Health Technologies and Systems, Texas A&M University, College Station, TX 77843-3577 (USA)
| | - Melissa A Grunlan
- Department of Biomedical Engineering, Texas A&M University, College Station, TX 77843-2120 (USA).,Department of Materials Science & Engineering, Texas A&M University, College Station, TX 77843 (USA).,Center for Remote Health Technologies and Systems, Texas A&M University, College Station, TX 77843-3577 (USA)
| |
Collapse
|
40
|
Abstract
Strategies to refine the degradation behavior of polyester biomaterials, particularly to overcome the limitations of slow hydrolytic degradation, would broaden their utility. Herein, we examine the complexities of polyester degradation behavior, its assessment and strategies for refinement. The factors governing polyester degradation are strikingly complex. In addition to the half-life of the hydrolytically-labile bond, a series of interdependent material properties must be considered. Thus, methods used to characterize such material properties, both before and during degradation, must be carefully selected. Assessment of degradation behavior is further complicated by the variability of reported test protocols and the need for accelerated rather than real-time in vitro testing conditions. Ultimately, through better control of degradation behavior and correlation of in vitro, simulated degradation to that observed in vivo, the development of superior devices prepared with polyester biomaterials may be achieved.
Collapse
Affiliation(s)
- Lindsay N. Woodard
- Department of Biomedical Engineering, Texas A&M University, College Station, Texas 77843, United States
| | - Melissa A. Grunlan
- Department of Biomedical Engineering, Texas A&M University, College Station, Texas 77843, United States
- Department of Materials Science and Engineering, Texas A&M University, College Station, Texas 77843, United States
- Department of Chemistry, Texas A&M University, College Station, Texas 77843, United States
| |
Collapse
|
41
|
Zouaghi S, Barry ME, Bellayer S, Lyskawa J, André C, Delaplace G, Grunlan MA, Jimenez M. Antifouling amphiphilic silicone coatings for dairy fouling mitigation on stainless steel. Biofouling 2018; 34:769-783. [PMID: 30332896 DOI: 10.1080/08927014.2018.1502275] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 03/30/2018] [Revised: 07/09/2018] [Accepted: 07/13/2018] [Indexed: 06/08/2023]
Abstract
Pasteurization of dairy products is plagued by fouling, which induces significant economic, environmental and microbiological safety concerns. Herein, an amphiphilic silicone coating was evaluated for its efficacy against fouling by a model dairy fluid in a pilot pasteurizer and against foodborne bacterial adhesion. The coating was formed by modifying an RTV silicone with a PEO-silane amphiphile comprised of a PEO segment and flexible siloxane tether ([(EtO)3Si-(CH2)2-oligodimethylsiloxanem-block-(OCH2CH2)n-OCH3]). Contact angle analysis of the coating revealed that the PEO segments were able to migrate to the aqueous interface. The PEO-modified silicone coating applied to pretreated stainless steel was exceptionally resistant to fouling. After five cycles of pasteurization, these coated substrata were subjected to a standard clean-in-place process and exhibited a minor reduction in fouling resistance in subsequent tests. However, the lack of fouling prior to cleaning indicates that harsh cleaning is not necessary. PEO-modified silicone coatings also showed exceptional resistance to adhesion by foodborne pathogenic bacteria.
Collapse
Affiliation(s)
- Sawsen Zouaghi
- a UMET (Unité Matériaux et Transformations) , Université de Lille , Lille , France
| | - Mikayla E Barry
- b Biomedical Engineering, Materials Science & Engineering , Texas A&M University , College Station , Texas , USA
| | - Séverine Bellayer
- a UMET (Unité Matériaux et Transformations) , Université de Lille , Lille , France
| | - Joël Lyskawa
- a UMET (Unité Matériaux et Transformations) , Université de Lille , Lille , France
| | - Christophe André
- a UMET (Unité Matériaux et Transformations) , Université de Lille , Lille , France
- c Hautes Etudes d'Ingénieur , Lille , France
| | - Guillaume Delaplace
- a UMET (Unité Matériaux et Transformations) , Université de Lille , Lille , France
- d INRA (Institut National de la Recherche Agronomique) , Villeneuve d'Ascq , France
| | - Melissa A Grunlan
- b Biomedical Engineering, Materials Science & Engineering , Texas A&M University , College Station , Texas , USA
| | - Maude Jimenez
- a UMET (Unité Matériaux et Transformations) , Université de Lille , Lille , France
| |
Collapse
|
42
|
Woodard LN, Kmetz KT, Roth AA, Page VM, Grunlan MA. Porous Poly(ε-caprolactone)-Poly(l-lactic acid) Semi-Interpenetrating Networks as Superior, Defect-Specific Scaffolds with Potential for Cranial Bone Defect Repair. Biomacromolecules 2017; 18:4075-4083. [PMID: 29037044 PMCID: PMC6371392 DOI: 10.1021/acs.biomac.7b01155] [Citation(s) in RCA: 37] [Impact Index Per Article: 5.3] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/19/2022]
Abstract
The treatment of irregular cranial bone defects is currently limited due to the graft resorption that can occur when an ill-fitting interface exists between an autograft and the surrounding tissue. A tissue engineering scaffold able to achieve defect-specific geometries could improve healing. This work reports a macroporous, shape memory polymer (SMP) scaffold composed of a semi-interpenetrating network (semi-IPN) of thermoplastic poly(l-lactic acid) (PLLA) within cross-linked poly(ε-caprolactone) diacrylate (PCL-DA) that is capable of conformal fit within a defect. The macroporous scaffolds were fabricated using a fused salt template and were also found to have superior, highly controlled properties needed for regeneration. Specifically, the scaffolds displayed interconnected pores, improved rigidity, and controlled, accelerated degradation. Although slow degradation rates of scaffolds can limit healing, the unique degradation behavior observed could prove promising. Thus, the described SMP semi-IPN scaffolds overcome two of the largest limitations in bone tissue engineering: defect "fit" and tailored degradation.
Collapse
Affiliation(s)
- Lindsay N. Woodard
- Department of Biomedical Engineering, Texas A&M University, College Station, Texas 77843, USA
| | - Kevin T. Kmetz
- Department of Biomedical Engineering, Texas A&M University, College Station, Texas 77843, USA
| | - Abigail A. Roth
- Department of Biomedical Engineering, Texas A&M University, College Station, Texas 77843, USA
| | - Vanessa M. Page
- Department of Biomedical Engineering, Texas A&M University, College Station, Texas 77843, USA
| | - Melissa A. Grunlan
- Department of Biomedical Engineering, Texas A&M University, College Station, Texas 77843, USA
- Department of Material Science and Engineering, Texas A&M University, College Station, Texas 77843, USA
| |
Collapse
|
43
|
Means AK, Ehrhardt DA, Whitney LV, Grunlan MA. Thermoresponsive Double Network Hydrogels with Exceptional Compressive Mechanical Properties. Macromol Rapid Commun 2017; 38:10.1002/marc.201700351. [PMID: 28895241 PMCID: PMC5878684 DOI: 10.1002/marc.201700351] [Citation(s) in RCA: 17] [Impact Index Per Article: 2.4] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/26/2017] [Revised: 07/31/2017] [Indexed: 11/12/2022]
Abstract
The utility of thermoresponsive hydrogels, such as those based on poly(N-isopropylacrylamide) (PNIPAAm), is severely limited by their deficient mechanical properties. In particular, the simultaneous achievement of high strength and stiffness remains unreported. In this work, a thermoresponsive hydrogel is prepared having the unique combination of ultrahigh compressive strength (≈23 MPa) and excellent compressive modulus (≈1.5 MPa). This is accomplished by employing a double network (DN) design comprised of a tightly crosslinked, highly negatively charged 1st network based on poly(2-acrylamido-2-methylpropane sulfonic acid (PAMPS) and a loosely crosslinked, zwitterionic 2nd network based on a copolymer of thermoresponsive NIPAAm and zwitterionic 2-(methacryloyloxy)ethyl]dimethyl-(3-sulfopropyl)ammonium hydroxide (MEDSAH). Comparison to other DN designs reveals that this PAMPS/P(NIPAAm-co-MEDSAH) DN hydrogel's remarkable properties stem from the intra- and internetwork ionic interactions of the two networks. Finally, this mechanically robust hydrogel retains the desirable thermosensitivity of PNIPAAm hydrogels, exhibiting a volume phase transition temperature of ≈35 °C.
Collapse
Affiliation(s)
- A Kristen Means
- Department of Materials Science & Engineering, Texas A&M University, College Station, TX, 77843-3003, USA
| | - Daniel A Ehrhardt
- Department of Biomedical Engineering, Texas A&M University, College Station, TX, 77843-3120, USA
| | - Lauren V Whitney
- Department of Biomedical Engineering, Texas A&M University, College Station, TX, 77843-3120, USA
| | - Melissa A Grunlan
- Department of Biomedical Engineering, Department of Materials Science & Engineering, Center for Remote Health Technologies Systems, Texas A&M University, College Station, TX, 77843-3120, USA
| |
Collapse
|
44
|
Abstract
Toward improving implantable medical devices as well as diagnostic performance, the development of polymeric biomaterials having resistance to proteins remains a priority. Herein, we highlight key strategies reported in the recent literature that have relied upon improvement of surface hydrophilicity via direct surface modification methods or with bulk modification using surface modifying additives (SMAs). These approaches have utilized a variety of techniques to incorporate the surface hydrophilization agent, including physisorption, hydrogel network formation, surface grafting, layer-by-layer (LbL) assembly and blending base polymers with SMAs. While poly(ethylene glycol) (PEG) remains the gold standard, new alternatives have emerged such as polyglycidols, poly(2-oxazoline)s (POx), polyzwitterions, and amphiphilic block copolymers. While these new strategies provide encouraging results, the need for improved correlation between in vitro and in vivo protein resistance is critical. This may be achieved by employing complex protein solutions as well as strides to enhance the sensitivity of protein adsorption measurements.
Collapse
Affiliation(s)
- Bryan Khai D. Ngo
- Department of Biomedical Engineering and ‡Department of Materials Science and Engineering, Texas A&M University, College Station, Texas 77843, United States
| | - Melissa A. Grunlan
- Department of Biomedical Engineering and ‡Department of Materials Science and Engineering, Texas A&M University, College Station, Texas 77843, United States
| |
Collapse
|
45
|
Hawkins ML, Schott SS, Grigoryan B, Rufin MA, Ngo BKD, Vanderwal L, Stafslien SJ, Grunlan MA. Anti-protein and anti-bacterial behavior of amphiphilic silicones. Polym Chem 2017; 8:5239-5251. [PMID: 29104619 PMCID: PMC5667680 DOI: 10.1039/c7py00944e] [Citation(s) in RCA: 35] [Impact Index Per Article: 5.0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/21/2022]
Abstract
Silicones with improved water-driven surface hydrophilicity and anti-biofouling behavior were achieved when bulk-modified with poly(ethylene oxide) (PEO) -silane amphiphiles of varying siloxane tether length: α-(EtO)3Si-(CH2)2-oligodimethylsiloxane m -block-poly(ethylene oxide)8-OCH3 (m = 0, 4, 13, 17, 24, and 30). A PEO8-silane [α-(EtO)3Si-(CH2)3-PEO8-OCH3] served as a conventional PEO-silane control. To examine anti-biofouling behavior in the absence versus presence of water-driven surface restructuring, the amphiphiles and control were surface-grafted onto silicon wafers and used to bulk-modify a medical-grade silicone, respectively. While the surface-grafted PEO-control exhibited superior protein resistance, it failed to appreciably restructure to the surface-water interface of bulk-modified silicone and thus led to poor protein resistance. In contrast, the PEO-silane amphiphiles, while less protein-resistant when surface-grafted onto silicon wafers, rapidly and substantially restructured in bulk-modified silicone, exhibiting superior hydrophilicity and protein resistance. A reduction of biofilm for several strains of bacteria and a fungus was observed for silicones modified with PEO-silane amphiphiles. Longer siloxane tethers maintained surface restructuring and protein resistance while displaying the added benefit of increased transparency.
Collapse
Affiliation(s)
- Melissa L Hawkins
- Department of Biomedical Engineering, Texas A&M University, College Station, TX 77843-3120
| | - Samantha S Schott
- Department of Biomedical Engineering, Texas A&M University, College Station, TX 77843-3120
| | - Bagrat Grigoryan
- Department of Biomedical Engineering, Texas A&M University, College Station, TX 77843-3120
| | - Marc A Rufin
- Department of Biomedical Engineering, Texas A&M University, College Station, TX 77843-3120
| | - Bryan Khai D Ngo
- Department of Biomedical Engineering, Texas A&M University, College Station, TX 77843-3120
| | - Lyndsi Vanderwal
- Office of Research & Creative Activity, North Dakota State University, Fargo, ND 58102
| | - Shane J Stafslien
- Office of Research & Creative Activity, North Dakota State University, Fargo, ND 58102
| | - Melissa A Grunlan
- Department of Biomedical Engineering, Texas A&M University, College Station, TX 77843-3120
- Department of Materials Science and Engineering, Texas A&M University, College Station, TX 77843-300
- Center for Remote Health Technologies System, Texas A&M University, College Station, TX 77843-3120
| |
Collapse
|
46
|
Rufin MA, Ngo BKD, Barry ME, Page VM, Hawkins ML, Stafslien SJ, Grunlan MA. Antifouling silicones based on surface-modifying additive amphiphiles. Green Mater 2017; 5:4-13. [PMID: 31673356 PMCID: PMC6822677 DOI: 10.1680/jgrma.16.00013] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/06/2023]
Abstract
Surface modifying additives (SMAs), which may be readily blended into silicones to improve anti-fouling behavior, must have excellent surface migration potential and must not leach into the aqueous environment. In this work, we evaluated the efficacy of a series of poly(ethylene oxide) (PEO)-based SMA amphiphiles which varied in terms of crosslinkability, siloxane tether length (m) and diblock versus triblock architectures. Specifically, crosslinkable, diblock PEO-silane amphiphiles with two oligodimethylsiloxane (ODMS) tether lengths [(EtO)3Si-(CH2)3-ODMS m -PEO8, m = 13 and 30] were compared to analogous non-crosslinkable, diblock (H-Si-ODMS m -PEO8) and triblock (PEO8-ODMS m -PEO8) SMAs. Prior to water conditioning, while all modified silicone coatings exhibited a high degree of water-driven surface restructuring, that prepared with the non-crosslinkable diblock SMA (m = 13) was the most hydrophilic. After conditioning, all modified silicone coatings were similarly hydrophilic and remained highly protein resistant, with the exception of PEO8-ODMS 30 -PEO8. Notably, despite twice the PEO content, triblock SMAs were not superior to diblock SMAs. For diblock SMAs, it was shown that water uptake and leaching were also similar whether or not the SMA was crosslinkable.
Collapse
Affiliation(s)
- Marc A Rufin
- Department of Biomedical Engineering, Texas A&M University, College Station, TX, USA
| | - Bryan Khai D Ngo
- Department of Biomedical Engineering, Texas A&M University, College Station, TX, USA
| | - Mikayla E Barry
- Department of Biomedical Engineering, Texas A&M University, College Station, TX, USA
| | - Vanessa M Page
- Department of Biomedical Engineering, Texas A&M University, College Station, TX, USA
| | - Melissa L Hawkins
- Department of Biomedical Engineering, Texas A&M University, College Station, TX, USA
| | - Shane J Stafslien
- Center for Nanoscale Science and Engineering, North Dakota State University, Fargo, ND, USA
| | - Melissa A Grunlan
- Department of Biomedical Engineering and Department of Materials Science and Engineering, Texas A&M University, College Station, TX, USA, 5030 Emerging Technologies Building, College Station, TX 77843-3120
| |
Collapse
|
47
|
Woodard LN, Page VM, Kmetz KT, Grunlan MA. PCL-PLLA Semi-IPN Shape Memory Polymers (SMPs): Degradation and Mechanical Properties. Macromol Rapid Commun 2016; 37:1972-1977. [DOI: 10.1002/marc.201600414] [Citation(s) in RCA: 21] [Impact Index Per Article: 2.6] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/30/2016] [Revised: 09/20/2016] [Indexed: 11/11/2022]
Affiliation(s)
- Lindsay N. Woodard
- Department of Biomedical Engineering; Texas A&M University; College Station TX 77843 USA
| | - Vanessa M. Page
- Department of Biomedical Engineering; Texas A&M University; College Station TX 77843 USA
| | - Kevin T. Kmetz
- Department of Biomedical Engineering; Texas A&M University; College Station TX 77843 USA
| | - Melissa A. Grunlan
- Department of Biomedical Engineering; Texas A&M University; College Station TX 77843 USA
- Department of Materials Science and Engineering; Texas A&M University; College Station TX 77843 USA
| |
Collapse
|
48
|
Rufin MA, Barry ME, Adair PA, Hawkins ML, Raymond JE, Grunlan MA. Protein resistance efficacy of PEO-silane amphiphiles: Dependence on PEO-segment length and concentration. Acta Biomater 2016; 41:247-52. [PMID: 27090588 PMCID: PMC5106186 DOI: 10.1016/j.actbio.2016.04.020] [Citation(s) in RCA: 22] [Impact Index Per Article: 2.8] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/05/2015] [Revised: 04/06/2016] [Accepted: 04/13/2016] [Indexed: 10/21/2022]
Abstract
UNLABELLED In contrast to modification with conventional PEO-silanes (i.e. no siloxane tether), silicones with dramatically enhanced protein resistance have been previously achieved via bulk-modification with poly(ethylene oxide) (PEO)-silane amphiphiles α-(EtO)3Si(CH2)2-oligodimethylsiloxane13-block-PEOn-OCH3 when n=8 and 16 but not when n=3. In this work, their efficacy was evaluated in terms of optimal PEO-segment length and minimum concentration required in silicone. For each PEO-silane amphiphile (n=3, 8, and 16), five concentrations (5, 10, 25, 50, and 100μmol per 1g silicone) were evaluated. Efficacy was quantified in terms of the modified silicones' abilities to undergo rapid, water-driven surface restructuring to form hydrophilic surfaces as well as resistance to fibrinogen adsorption. Only n=8 and 16 were effective, with a lower minimum concentration in silicone required for n=8 (10μmol per 1g silicone) versus n=16 (25μmol per 1g silicone). STATEMENT OF SIGNIFICANCE Silicone is commonly used for implantable medical devices, but its hydrophobic surface promotes protein adsorption which leads to thrombosis and infection. Typical methods to incorporate poly(ethylene oxide) (PEO) into silicones have not been effective due to the poor migration of PEO to the surface-biological interface. In this work, PEO-silane amphiphiles - comprised of a siloxane tether (m=13) and variable PEO segment lengths (n=3, 8, 16) - were blended into silicone to improve its protein resistance. The efficacy of the amphiphiles was determined to be dependent on PEO length. With the intermediate PEO length (n=8), water-driven surface restructuring and resulting protein resistance was achieved with a concentration of only 1.7wt%.
Collapse
Affiliation(s)
- Marc A Rufin
- Department of Biomedical Engineering, Texas A&M University, United States
| | - Mikayla E Barry
- Department of Biomedical Engineering, Texas A&M University, United States
| | - Paige A Adair
- Department of Biomedical Engineering, Texas A&M University, United States
| | - Melissa L Hawkins
- Department of Biomedical Engineering, Texas A&M University, United States
| | | | - Melissa A Grunlan
- Department of Biomedical Engineering, Texas A&M University, United States; Department of Materials Science and Engineering, Texas A&M University, United States.
| |
Collapse
|
49
|
Fei R, Means AK, Abraham AA, Locke AK, Coté GL, Grunlan MA. Self-Cleaning, Thermoresponsive P (NIPAAm-co-AMPS) Double Network Membranes for Implanted Glucose Biosensors. Macromol Mater Eng 2016; 301:935-943. [PMID: 28529447 PMCID: PMC5438207 DOI: 10.1002/mame.201600044] [Citation(s) in RCA: 17] [Impact Index Per Article: 2.1] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/07/2023]
Abstract
A self-cleaning membrane that periodically rids itself of attached cells to maintain glucose diffusion could extend the lifetime of implanted glucose biosensors. Herein, we evaluate the functionality of thermoresponsive double network (DN) hydrogel membranes based on poly(N-isopropylacrylamide) (PNIPAAm) and an electrostatic co-monomer, 2-acrylamido-2-methylpropane sulfonic acid (AMPS). DN hydrogels are comprised of a tightly crosslinked, ionized first network [P(NIPAAm-co-AMPS)] containing variable levels of AMPS (100:0-25:75 wt% ratio of NIPAAm:AMPS) and a loosely crosslinked, interpenetrating second network [PNIPAAm]. To meet the specific requirements of a subcutaneously implanted glucose biosensor, the volume phase transition temperature is tuned and essential properties, such as glucose diffusion kinetics, thermosensitivity, and cytocompatibility are evaluated. In addition, the self-cleaning functionality is demonstrated through thermally driven cell detachment from the membranes in vitro.
Collapse
Affiliation(s)
- Ruochong Fei
- Department of Biomedical Engineering, Texas A&M University, College Station, TX 77843-3120, USA
| | - A Kristen Means
- Department of Materials Science and Engineering, Texas A&M University, College Station, TX 77843-3003, USA
| | - Alexander A Abraham
- Department of Biomedical Engineering, Texas A&M University, College Station, TX 77843-3120, USA
| | - Andrea K Locke
- Department of Biomedical Engineering, Texas A&M University, College Station, TX 77843-3120, USA
| | - Gerard L Coté
- Department of Biomedical Engineering, Texas A&M University, College Station, TX 77843-3120, USA
| | - Melissa A Grunlan
- Department of Biomedical Engineering, Texas A&M University, College Station, TX 77843-3120, USA
| |
Collapse
|
50
|
Erndt-Marino JD, Munoz-Pinto DJ, Samavedi S, Jimenez-Vergara AC, Diaz-Rodriguez P, Woodard L, Zhang D, Grunlan MA, Hahn MS. Evaluation of the Osteoinductive Capacity of Polydopamine-Coated Poly( ε-caprolactone) Diacrylate Shape Memory Foams. ACS Biomater Sci Eng 2015; 1:1220-1230. [PMID: 33304994 DOI: 10.1021/acsbiomaterials.5b00445] [Citation(s) in RCA: 39] [Impact Index Per Article: 4.3] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/17/2022]
Abstract
Recently, a novel shape memory polymer foam based on the photopolymerization of poly(ε-caprolactone) diacrylate (PCLDA) has been developed. These PCLDA foams enter a temporary softened state when briefly treated with warm saline (T saline > T m of PCLDA), allowing them to conform to irregular bone defect "boundaries" prior to shape setting. When coated with a mechanically stable polydopamine (PD) layer, these PCLDA foams have previously been demonstrated to induce hydroxyapatite deposition. In the present study, the osteoinductivity of these "self-fitting" PD-coated PCLDA (PD-PCLDA) materials was evaluated relative to uncoated PCLDA (U-PCLDA) controls using bone marrow-derived human mesenchymal stem cells (h-MSCs). When cultured in the absence of osteogenic media supplements, PD-PCLDA scaffolds expressed similar levels of Runx2, alkaline phosphatase, and osteopontin protein as U-PCLDA scaffolds cultured in the presence of osteogenic media supplements. In addition, PD-PCLDA scaffolds cultured without osteogenic supplements did not significantly promote undesired lineage progression (e.g., adipogenesis or chondrogenesis) of h-MSCs. Cumulatively, these data indicate that PD-PCLDA materials display increased osteoinductivity relative to U-PCLDA substrates. Future studies will examine tethered osteogenic factors or peptides toward augmenting the osteoinductive properties of the PD-PCLDA foams.
Collapse
Affiliation(s)
- Joshua D Erndt-Marino
- Department of Biomedical Engineering, Rensselaer Polytechnic Institute, Troy, New York 12180, United States
| | - Dany J Munoz-Pinto
- Department of Biomedical Engineering, Rensselaer Polytechnic Institute, Troy, New York 12180, United States
| | - Satyavrata Samavedi
- Department of Biomedical Engineering, Rensselaer Polytechnic Institute, Troy, New York 12180, United States
| | - Andrea C Jimenez-Vergara
- Department of Biomedical Engineering, Rensselaer Polytechnic Institute, Troy, New York 12180, United States
| | - Patricia Diaz-Rodriguez
- Department of Biomedical Engineering, Rensselaer Polytechnic Institute, Troy, New York 12180, United States
| | - Lindsay Woodard
- Department of Biomedical Engineering, Texas A&M University, College Station, Texas 77843, United States
| | - Dawei Zhang
- Department of Materials Science and Engineering, Texas A&M University, College Station, Texas 77843, United States
| | - Melissa A Grunlan
- Department of Biomedical Engineering, Texas A&M University, College Station, Texas 77843, United States.,Department of Materials Science and Engineering, Texas A&M University, College Station, Texas 77843, United States
| | - Mariah S Hahn
- Department of Biomedical Engineering, Rensselaer Polytechnic Institute, Troy, New York 12180, United States
| |
Collapse
|