1
|
Zaldivar R, Zaldivar R, Gordillo CH, Adamek P. Visual Acuity Improvement in Low, Moderate and High Myopia After Posterior-Chamber Phakic Implantable Collamer Lens Surgery in a Large Patient Cohort. Clin Ophthalmol 2023; 17:1179-1185. [PMID: 37096208 PMCID: PMC10122501 DOI: 10.2147/opth.s407492] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/07/2023] [Accepted: 04/11/2023] [Indexed: 04/26/2023] Open
Abstract
Purpose To compare best-corrected visual acuity (BCVA) before and after implantable collamer lens (ICL) surgery in patients with low, moderate and high myopia. Methods A single-centre, prospective, registry-based study involving patients with myopia who received ICLs between October 2018 and August 2020. The study population was divided into three groups of subjects with low (from 0 to -6 D), moderate (-6 to -10 D) and high myopia (more than -10 D). We analysed uncorrected visual acuity (UCVA), best-corrected visual acuity (BCVA), spherical equivalent (SE), differences between BCVA pre- and 1-month postoperative, and line gain in BCVA 1 month after surgery. Results A total of 770 eyes belonging to 473 patients were surgically intervened during the study period, of which 692 eyes completed 1 month of postoperative follow-up and were included in the study population. At 1-month follow-up, 478 eyes (69%) achieved a BCVA of 20/20, 599 (87%) obtained 20/25 or better, and 663 (96%) had a BCVA of 20/40 or better. We identified a significant improvement in BCVA (baseline 0.15±0.2 logMAR vs follow-up 0.07±0.2 logMAR, p<0.0001) and a significant reduction in SE (baseline -9.23±4.1 D, vs follow-up -0.21±0.8 D, p<0.0001), with a significant relationship between preoperative SE and line gain (r = -0.46, p<0.0001). We identified a significantly higher line gain among eyes with higher degrees of myopia (low myopia 0.22±0.69 lines compared to moderate myopia 0.56±1.1 lines and high myopia 1.51±1.9 lines, p<0.0001). Notably, 99.6% of eyes with a high grade of myopia achieved improvement to a low degree (less than -6 D) at follow-up. The safety and efficacy indexes were 0.083±0.1 and -0.001±0.1, respectively. Conclusion In this large patient cohort, ICL surgery was related to a significant line gain in BCVA, particularly among eyes with higher degrees of myopia.
Collapse
Affiliation(s)
- Roger Zaldivar
- Surgery Department, Instituto Zaldivar, Mendoza, Argentina
- Correspondence: Roger Zaldivar, Instituto Zaldivar, Av. Emilio Civit 701, Mendoza, Argentina, Email
| | | | | | - Pablo Adamek
- Surgery Department, Instituto Zaldivar, Mendoza, Argentina
| |
Collapse
|
2
|
Zaldivar R, Zaldivar R, Adamek P, Quintero G, Cerviño A. Descriptive Analysis of Footplate Position After Myopic Implantable Collamer Lens Implantation Using a Very High-Frequency Ultrasound Robotic Scanner. Clin Ophthalmol 2022; 16:3993-4001. [PMID: 36504639 PMCID: PMC9733561 DOI: 10.2147/opth.s393223] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/12/2022] [Accepted: 11/17/2022] [Indexed: 12/07/2022] Open
Abstract
Purpose To assess the position of the haptics of the implantable collamer lens (ICL) in myopic eyes using a high-frequency ultrasound robotic scanner. Methods This was a prospective, single-arm, observational study carried out at the Instituto Zaldivar SA (Mendoza, Argentina) in a sample of 52 eyes who have been submitted to successful ICL implantation prior to enrollment. Images of the eyes were obtained using a very-high frequency digital ultrasound robotic scanner (VHFDU) to establish the position of the ICL in the posterior chamber and its relation to the ciliary sulcus. New parameters for lens position analysis were also described. Results In 81% of cases (42 eyes), the ICL rests on the ciliary body (CB) in both temporal and nasal sides, being slightly lower than 6% (3 eyes) those that rest on the sulcus in both sides, with significant correlations between ICL position and vault values (p<0.05). Cases in which the ICL position was CB-CB yielded central vault values across the whole range determined within the sample, but most of the eyes where the ICL rests on both the sulcus in one side and the CB in the other yield greater central vault values. Correlation was significant between ICL position and retroposition distance on the temporal side (Spearman's rho -0.487, p<0.001). A significant but weaker correlation was also found between ICL position and retroiridian space (p<0.05). Conclusion ICL for myopia footplates tend to locate outside of the sulcus in a significant percentage of patients after successful implantation. VHFDU assessment in eyes implanted with an ICL to properly study the lens footplate position and posterior anatomical relations provides important additional information besides post-surgery vault.
Collapse
Affiliation(s)
| | | | | | | | - Alejandro Cerviño
- Department of Optics & Optometry & Vision Sciences, University of Valencia, Valencia, Spain,Correspondence: Alejandro Cerviño, Department of Optics & Optometry & Vision Science, University of Valencia, C / Dr. Moliner, 50. Burjassot, Valencia, 46100, Spain, Tel +34 963 544 852, Email
| |
Collapse
|
3
|
Zaldivar R. March consultation #6. J Cataract Refract Surg 2016; 42:501. [DOI: 10.1016/j.jcrs.2016.02.017] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/22/2022]
|
4
|
Zaldivar R. March consultation #5. J Cataract Refract Surg 2011. [DOI: 10.1016/j.jcrs.2011.01.006] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/29/2022]
|
5
|
Abstract
PURPOSE To determine whether five changes to our hyperopic LASIK protocol produced better outcomes. METHODS Five changes, both technical and surgical, were instituted for the treatment of hyperopia. These five changes were nomogram refinements accounting for accommodation, use of a 7.0-mm optical zone and a 9.5-mm transition zone, a targeted mean flap diameter of 10.5 mm, sequential interruption of the laser ablation, and cleaning of the interface. The study comprised 43 eyes undergoing LASIK for hyperopia or hyperopic astigmatism with a mean preoperative spherical equivalent refraction of +2.28 diopters (D), a mean sphere of +1.93 D (range: +4.25 to +0.25 D), and mean cylinder of +1.10 D (range: +4.50 to +0.25 D). The NIDEK CXII excimer laser was used for all treatments. RESULTS From 1 day to 3 months postoperatively, the mean hyperopic shift was <0.50 D. Postoperatively, the number of patients achieving a distance best spectacle-corrected visual acuity (BSCVA) of 20/20 gradually increased to 93% by 3 months. The number of eyes that achieved 20/15 increased by 11.7% compared to preoperatively. Eighty-eight percent of eyes maintained or gained lines of BSCVA. Four patients lost 1 line of BSCVA. One patient lost >1 line of vision due to visually significant microstriae. CONCLUSIONS The outcomes support the observation that five surgical and technical modifications to the hyperopic LASIK procedure result in excellent visual quality and refractive outcomes and a low rate of regression.
Collapse
|
6
|
Abstract
PURPOSE To evaluate predictability, safety, stability, and complications related to bioptics in patients that received phakic and those that received pseudophakic intraocular lenses. Both groups had LASIK with the Nidek EC-5000 excimer laser following IOL implantation. METHODS We evaluated retrospectively 281 eyes of 196 patients with posterior chamber phakic implantation (ICL) and 64 pseudophakic eyes of 55 patients. All patients had LASIK 1 month or more after the first surgery. We used a treatment zone of 5.5 mm with a 7.00-mm transition zone. The flap was made with the Automated Corneal Shaper (ACS). RESULTS In the group of phakic ICL eyes with bioptics, preoperative mean spherical equivalent refraction was -5.50 D (range, -1.37 to -16.00 D). The first day after LASIK, mean spherical equivalent refraction was -0.06 D, and at 1 month, -0.40 D. In pseudophakic bioptics eyes, preoperative mean spherical equivalent refraction was -2.61 D (range, +0.50 to -5.50 D). The first day after LASIK it was +0.27 D, and 1 month after LASIK it was +0.09 D. The incidence of complications was similar in both groups of patients. The most frequent complication was keratitis sicca (approximately 10% in each group). Interstitial edema (2.1%) was present only in phakic bioptics eyes. No retinal complications were observed. Refraction was stable 4 years after surgery. Target achieved refraction was +/- 0.50 D, showing the predictability of the procedure. CONCLUSIONS Predictability and safety were demonstrated according to results and absence of severe complications related with this technique. Older patients did not develop more complications than younger people; dry eye incidence was similar in both groups. In extreme myopia patients did not present retinal complications related to surgical procedures.
Collapse
|
7
|
|
8
|
Abstract
PURPOSE To determine the variables that might contribute to improved intraocular lens (IOL) power calculations preoperatively in cataract patients with extreme myopia. METHODS This retrospective study included 50 patients with extreme myopia and axial lengths longer than 27.0 mm. All patients had clear corneal phacoemulsification by the same surgeon and implantation of the Domilens SiFlex 1 IOL (power range -6.0 to +5.0 diopters [D]). The performances of the SRK/T, Hoffer Q, Holladay 1, and Holladay 2 formulas in predicting an IOL power that would meet the target refraction of +/-1.00 D were compared. RESULTS The formulas tended to suggest underpowered IOLs, more severe in eyes with axial lengths greater than 30.00 mm. These eyes accounted for most of the minus-power IOLs implanted. Back calculations of axial lengths in patients with minus-power IOLs showed that, on average, emmetropia could have been predicted by choosing shorter axial lengths (up to 2.72 mm shorter) than those used in the original IOL power calculations. Preoperative B-scan ultrasonography demonstrated the presence of a posterior pole staphyloma temporal to the optic nerve in several patients who required minus-power IOLs, which suggests that axial length measurement problems were a major source of IOL calculation errors in these patients. CONCLUSIONS In eyes with axial lengths longer than or equal to 27.0 mm, current third- and fourth-generation lens calculation formulas have a tendency to over minus patients between -1.0 and -4.0 D. The formulas appear to perform better for plus-power IOL implantation than for minus-power IOL implantation. The use of B-scan ultrasonography to locate posterior pole staphylomas may improve the accuracy of IOL calculations in eyes with extreme myopia.
Collapse
|
9
|
Zaldivar R. Refractive surgical problem: Reply. J Cataract Refract Surg 2000. [DOI: 10.1016/s0886-3350(99)00427-7] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/18/2022]
|
10
|
Abstract
Phakic Intraocular surgery has come a long way in the past 20 years, especially in the evolution of posterior chamber phakic intraocular lenses (PC PIOLs). Clinical trials worldwide are showing acceptable results concerning efficacy, predictability, stability, and safety. PC PIOLS are proving to be a promising option for patients with high and extreme ametropia who cannot benefit from conventional corneal refractive procedures. This article provides an in-depth examination of PC PIOLs, their origin and evolution, and the results of past and current clinical studies. Reports of historical importance and studies published since the 1990s in peer-reviewed journals, textbooks, and monthly eye magazines, as well as Food and Drug Administration preliminary clinical findings, are reviewed. Anterior chamber phakic intraocular lenses are mentioned briefly.
Collapse
Affiliation(s)
- R Zaldivar
- Department of the Refractive and Cataract Surgery Program, Instituto Zaldivar, Mendoza, Argentina.
| | | | | |
Collapse
|
11
|
Zaldivar R, Davidorf JM, Oscherow S, Ricur G, Piezzi V. Combined posterior chamber phakic intraocular lens and laser in situ keratomileusis: bioptics for extreme myopia. J Refract Surg 1999; 15:299-308. [PMID: 10367571 DOI: 10.3928/1081-597x-19990501-04] [Citation(s) in RCA: 7] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [MESH Headings] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 04/13/2023]
Abstract
PURPOSE To examine the efficacy, predictability, stability, and safety of combined posterior chamber phakic intraocular lens (IOL) implantation and laser in situ keratomileusis (LASIK) in eyes with extreme myopia. METHODS We analyzed the results of 67 eyes that received a posterior chamber hydrogel-collagen plate phakic IOL (STAAR Collamer Implantable Contact Lens) and also underwent secondary LASIK for the correction of extreme myopia. Mean follow-up was 3 months after the LASIK portion of the procedure (range, 1 day to 6 mo after LASIK). RESULTS Mean preoperative spherical equivalent refraction was -23.00 +/- 3.60 D (range, -18.75 to -35.00 D), and mean refractive cylinder was 1.50 +/- 1.20 D (range, 0 to 5.00 D). Mean spherical equivalent refraction after IOL implantation and before LASIK was -6.00 +/- 2.80 D (range, -2.00 to -14.38 D) and mean refractive cylinder 1.50 +/- 1.10 D (range, 0 to 5.00 D). Mean postoperative spherical equivalent refraction at last examination after the LASIK portion of the two-part phakic IOL-LASIK procedure was -0.20 +/- 0.90 D (range, +1.75 to -5.13 D), and mean refractive cylinder was 0.50 +/- 0.50 (range, 0 to 2.25 D). Eighty-five percent (57 eyes) were within +/- 1.00 D and 67% (45 eyes) were within +/- 0.50 D of emmetropia at last examination. The refractions remained stable with a statistically insignificant change (P > .05 at each interval) during follow-up. Postoperative uncorrected visual acuity at last examination was 20/20 or better in 3% (2 eyes) and 20/40 or better in 69% (46 eyes). A gain of 2 or more lines of spectacle-corrected visual acuity was seen in 51 eyes (76%) and no eyes lost 2 or more lines of spectacle-corrected visual acuity at last examination. CONCLUSION Combined posterior chamber phakic IOL implantation with the STAAR Collamer plate lens and LASIK (bioptics) is an effective and reasonably predictable method for correcting myopia from -18 to -35 D. Gains in spectacle-corrected visual acuity were common, and results demonstrated good short-term safety and refractive stability.
Collapse
|
12
|
Zaldivar R, Oscherow S, Ricur G, Piezzi V. Bilateral simultaneous laser in situ keratomileusis. J Refract Surg 1999; 15:S202-8. [PMID: 10202721 DOI: 10.3928/1081-597x-19990302-10] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [MESH Headings] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 04/13/2023]
|
13
|
Abstract
PURPOSE To examine the efficacy, predictability, stability, and safety of posterior chamber phakic intraocular lens (IOL) implantation in eyes with high hyperopia. METHODS We analyzed the results of 24 eyes that received a posterior chamber hydrogel-collagen plate phakic IOL (Staar Collamer Implantable Contact Lens, ICL) for the correction of hyperopia with the goal of emmetropia. Mean follow-up was 8.4 months (range, 1 to 18 mo). RESULTS The mean preoperative spherical equivalent refraction was +6.51 +/- 2.08 D (range, +3.75 to +10.50 D). Mean postoperative spherical equivalent refraction at last examination was -0.39 +/- 1.29 D (range, +1.25 to -3.88 D), with 79% (19 eyes) within +/-1.00 D and 58% (14 eyes) within +/-0.50 D of emmetropia. Postoperative uncorrected visual acuity at last examination was 20/20 or better in 8% (two eyes) and 20/40 or better in 63% (15 eyes). A gain of two or more lines of spectacle-corrected visual acuity was seen in two eyes (8%) at last examination. One eye (4%) lost two or more lines of spectacle-corrected visual acuity due to progressive neovascular glaucoma initiated by early postoperative pupillary block. CONCLUSION Posterior chamber phakic IOL implantation with the Staar Collamer plate lens is an effective method for correcting high hyperopia. Large, patent iridotomies are important in hyperopic eyes to lower the risk of postoperative pupillary block. Improved phakic IOL power calculation formulas will refine predictability of refractive outcome.
Collapse
|
14
|
Abstract
PURPOSE To examine the efficacy, predictability, stability, and safety of posterior chamber phakic intraocular lens (IOL) implantation in patients with extreme myopia. METHODS We analyzed the results of 124 eyes that received a posterior chamber hydrogel collagen plate phakic IOL (Staar Collamer Implantable Contact Lens, ICL) for the correction of their myopia. The target postoperative spherical equivalent refraction was emmetropia. Mean follow-up was 11 months (range 1 to 36 mo). RESULTS The mean preoperative spherical equivalent refraction was -13.38 +/- 2.23 D (range, -8.50 to -18.63 D). Mean postoperative spherical equivalent refraction at last examination was -0.78 +/- 0.87 D (range, +1.63 to -3.50 D), with 69% (86 eyes) within +/-1.00 D and 44% (55 eyes) within +/-0.50 D of emmetropia. The refraction remained stable with a statistically insignificant change (p > 0.05 at each interval) during follow-up. A gain of two or more lines of spectacle-corrected visual acuity was seen in 36% (45 eyes) at last examination. One eye (0.8%) lost two or more lines of spectacle-corrected visual acuity from a retinal detachment. CONCLUSION Posterior chamber phakic IOL implantation with the Staar Collamer plate lens is an effective and safe method for reducing or correcting myopia between -8 and -19 D. Gains in spectacle-corrected visual acuity were common, and results suggested good refractive stability. Improvements in phakic IOL power calculation formulas are needed to improve the predictability of refractive outcome.
Collapse
|
15
|
Abstract
PURPOSE To identify intraoperative and early postoperative adverse events and complications that may be encountered after the laser in-situ keratomileusis (LASIK) learning process. METHODS One hundred sixty-nine consecutive eyes of 108 patients who had LASIK by a surgeon experienced in LASIK were studied. All intraoperative and early postoperative adverse events and complications were noted. Patients were examined at 1 day and 1 to 3 months after surgery. Six baseline refractive groups were studied: high myopia with astigmatism (-10.25 to -17.50 D; 18 eyes), moderate myopia with astigmatism (-6.00 to -9.50 D; 31 eyes), low myopia with astigmatism (-0.75 to -5.87 D; 81 eyes), mixed astigmatism (-0.25 to +0.50 D; 6 eyes), low to moderate hyperopia with astigmatism (+1.00 to +3.75 D; 19 eyes), and high hyperopia with astigmatism (+4.25 to +7.37 D; 12 eyes). Seventy-eight percent (132 eyes) had a primary LASIK procedure; 22% (37 eyes) had LASIK after previous refractive surgery. Primary and secondary LASIK procedures were analyzed together. The Nidek EC-5000 or the Chiron PlanoScan excimer lasers were used. RESULTS The most commonly observed adverse intraoperative events were minor corneal bleeding (3%) and thin flap (1%). The most commonly observed postoperative events were punctate epithelial keratopathy (6%) and small epithelial defect 1 day after surgery (5%). The most serious complication occurred in three eyes with preoperative high hyperopia (spherical equivalent refraction greater than +4.00 D) in which corneal topographic abnormalities resulted. At last examination, mean postoperative spherical equivalent refraction was less than +1.00 D in all groups. Spectacle-corrected visual acuity was 20/20 in 70 eyes (41%) and 20/25 or better in 119 eyes (70%). Loss of spectacle-corrected visual acuity of two or more lines occurred in five eyes (3%), three of which had preoperative high hyperopia with abnormal postoperative corneal topography. CONCLUSION Our prospective study should help LASIK surgeons gauge their expectations of intraoperative and early postoperative complications. Surgeons should proceed cautiously when treating patients with high hyperopia, because a higher incidence of loss of spectacle-corrected visual acuity may be encountered postoperatively.
Collapse
|
16
|
Abstract
PURPOSE To determine the efficacy, predictability, safety, and short-term stability of laser in situ keratomileusis (LASIK) in treating patients with high myopia and astigmatism. METHODS We retrospectively studied the results of our initial 119 eyes with myopia ranging from -5.50 to -11.50 D and astigmatism less than 4.00 D that underwent LASIK with the Nidek EC-5000 excimer laser. Follow-up was at 1 day, 1 month, and 3 to 6 months; follow-up was 71% (84 eyes) at the 3 to 6 month visit (average 4.5 months). RESULTS Of the 84 eyes with 3 to 6 months of follow-up, mean baseline spherical equivalent refraction was -8.62 +/- 1.27 D and mean cylinder was -1.84 +/- 1.02 D. Mean postoperative spherical equivalent refraction at the last examination was -0.61 +/- 0.84 D and mean cylinder was -0.39 +/- 0.38 D, with 83% (70 eyes) achieving a spherical equivalent refraction within +/-1.00 D of emmetropia, and 56% (47 eyes) within +/-0.50 D. Mean regression of spherical equivalent from 1 day to 1 month was less than -0.50 D and refractions were stable between 1 month and 3 to 6 months. An uncorrected visual acuity of 20/40 or better was noted in 84% (71 eyes) of these eyes on day 1 after surgery, in 75% (63 eyes) at 1 month, and in 77% (65 eyes) at 3 to 6 months. Twenty-two percent (18 eyes) of these eyes achieved 20/20 or better uncorrected visual acuity at 3 to 6 months; only 17% (14 eyes) had 20/20 or better spectacle-corrected visual acuity before surgery. One patient lost two or more lines of spectacle-corrected visual acuity at the last examination due to epidemic keratoconjunctivitis. CONCLUSION LASIK with the Nidek EC-5000 excimer laser appears to be an effective and safe means for treating patients with high myopia and astigmatism. Studies with longer follow-up will help evaluate the long-term stability of the procedure and the possibility of late complications.
Collapse
|
17
|
Abstract
PURPOSE To determine the efficacy, predictability, safety, and short term stability of laser in situ keratomileusis (LASIK) in treating patients with low myopia and astigmatism using the Chiron Technolas Keracor 117 PlanoScan excimer laser. METHODS We retrospectively studied the results of our initial 83 eyes with myopia ranging from -1.13 to -7.25 diopters (D) and astigmatism of no more than 4.00 D that underwent LASIK with the Chiron Technolas Keracor 117 PlanoScan. Follow-up was at 1 day, 1 month, and 3 to 6 months. RESULTS Mean baseline spherical equivalent refraction was -3.54 +/- 1.41 D and cylinder -1.64 +/- 1.14 D. Mean postoperative spherical equivalent refraction was -0.52 +/- 0.50 D at 1 month and -0.65 +/- 0.62 D at 3 to 6 months; mean postoperative refractive cylinder was -0.45 +/- 0.54 D at 1 month and -0.50 +/- 0.63 D at 3 to 6 months. Fifty-three percent (44 eyes) achieved a spherical equivalent refraction within +/- 0.50 D and 81% (67 eyes) within +/- 1.00 D of emmetropia at the last examination. Fifty-seven percent (47 eyes) achieved a refractive cylinder of < or = 0.50 D, and 27% (22 eyes) had an undercorrection of their refractive cylinder at the last examination. An uncorrected visual acuity of 20/40 or better was achieved in 86% (71 eyes) of patients on postoperative day one, in 81% (67 eyes) at 1 month, and in 76% (63 eyes) at 3 to 6 months. Twenty-eight percent (23 eyes) saw 20/20 or better uncorrected at the last visit (41% [34 eyes] had a baseline spectacle-corrected visual acuity of 20/20). There was no statistically significant difference in the refractions or uncorrected visual acuities between the different postoperative examinations. No eye experienced a loss of spectacle-corrected visual acuity of more than one line at the last examination. CONCLUSION LASIK with the Chiron PlanoScan excimer laser appears to be an effective, safe, and reasonably predictable means to reduce low myopia and astigmatism. Adjustment of computer algorithms is needed to decrease the number of under-corrections.
Collapse
|
18
|
|
19
|
|
20
|
Abstract
A series of 54 eyes in 50 patients had preoperative predictions of postoperative visual acuity, using both a white-light interferometer (Lotmar Visometer) and a Snellen chart projector (Guyton-Minkowski Potential Acuity Meter). The predicted vision by each instrument was compared with the actual postoperative vision. Forty eyes in 36 of these patients, 25 with concurrent eye disease, had cataract extraction with intraocular lens implantation. Fifteen eyes in 15 patients, 11 with concurrent eye disease, had neodymium-YAG laser posterior capsulotomy. The Visometer gave more accurate predictions than the Potential Acuity Meter in cataract patients with open angle glaucoma, even with glaucomatous visual field loss, and in patients with a visual acuity of less than 20/400 due to advanced cataract formation.
Collapse
|
21
|
Zaldivar R. Epidemiology of gastric and colo-rectal cancer in the United States and Chile with particular reference to the role of dietary and nutritional variables, nitrate fertilizer pollution, and N-nitroso compounds. Zentralbl Bakteriol Orig B 1977; 164:193-217. [PMID: 888597] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [MESH Headings] [Subscribe] [Scholar Register] [Indexed: 12/24/2022]
|
22
|
|
23
|
Zaldivar R. [Pathological study of stomach carcinoma in autopsied patients of low socioeconomical level]. Rev Med Chil 1971; 99:834-8. [PMID: 5171835] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [MESH Headings] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/14/2023]
|
24
|
Zaldivar R. [Pathological anatomy of the precursors of gastric carcinoma in Chilean patients, including various experimental aspects: critical review of the literature]. Rev Med Chil 1971; 99:876-81. [PMID: 4945074] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/13/2023]
|